Loading...
HomeMy WebLinkAboutPermit D10-244 - WESTFIELD SOUTHCENTER MALL - VACANT SPACE - BUILD OUTVACANT SPACE 973 SOUTHCENTER MALI. D1O-244 City ofkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 973 SOUTHCENTER MALL TUKW Suite No: Project Name: VACANT SPACE Permit Number: D10-244 Issue Date: 10/18/2010 Permit Expires On: 04/16/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: WAYNE JOHNSON Address: 4000 DELRIDGE WY SW #200 , SEATTLE WA 98106 Contractor: Name: B N BUILDERS INC Address: 2601 4 AV STE 350 , SEATTLE WA 98121 Contractor License No: BNBUII *990K3 Phone: 206 624 -2777 Phone: 206 382 -3443 Expiration Date: 09/12/2011 DESCRIPTION OF WORK: LANDLORD BUILD OUT OF NEW MALL STOREFRONT FOR FUTURE TENANT WITHIN EXISTING MALL Value of Construction: $8,500.00 Fees Collected: $433.01 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: 18 Occupancy per IBC: 0019 * *continued on next page ** doc: IBC -10/06 D10 -244 Printed: 10 -18 -2010 City ofkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us Permit Number: D10 -244 Issue Date: 10/18/2010 Permit Expires On: 04/16/2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non- Profit: N Water Main Extension: Private: Public: Water Meter: Permit Center Authorized Signature: N Date: ITV i, D `4 J I hereby certify that I have read and e - - d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction the performance of work. I am authorized to sign and obtain this development permit. Signature: Date: I 0 / ( . / ( Print Name: �H'p C� t`-4 l ' i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IBC -10/06 D10 -244 Printed: 10 -18 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http. //www.ci.tukwila.wa.us Parcel No.: 9202470010 Address: 973 SOUTHCENTER MALL TUKW Suite No: Tenant: VACANT SPACE PERMIT CONDITIONS Permit Number: D10-244 Status: ISSUED Applied Date: 09/07/2010 Issue Date: 10/18/2010 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors m the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDITIONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface m accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) doc: Cond -10/06 D10 -244 Printed: 10 -18 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us • 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 21: Maintain sprinlder coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 22: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinlder systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of the W.S.R.B., Factory Mutual, Industrial Risk Insurers Kemper or any other representative designated and /or recognized by the City of Tukwila, prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance #2050) 24: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2051. (FIRE ALARM NOTIFICATION INCLUDING VOICE EVAC UPGRADE REQUIRED. ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 25: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 26: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 27: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. doc: Cond -10/06 D10 -244 Printed: 10 -18 -2010 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http. / /www.ci.tukwila.wa.us 28: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 29: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed m a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) (POST ADDRESS ON STOREFRONT PER APPROVED WESTFIELD STANDARDS.) 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 31: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 32: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. * *continued on next page ** doc: Cond -10/06 D10 -244 Printed: 10 -18 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tulcwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work or local laws regulating construction or the performance of work. --"lf\-0-),)\ Signature: cw"‘2-6(--7--) Print Name: T -t' 1 , u1 7 ° Date: I o JcCD doc: Cond -10/06 D10 -244 Printed: 10 -18 -2010 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hap.:%irwlr. ci. tukivila. iva. us Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** _ King Co Assessor's Tax No.: 2(�23c- q— 00 /0 Site Address: 9'%3 soic1}}(- AAPU. Suite Number: 2-52 Floor: I ST- Tenant Name: I,4.1•E�T 'j 1,1 New Tenant: ❑ Yes X.No Property Owners Name: t4- U.1H c r'Ep_ Mailing Address: -2-goc s S �� -r["ti �e4T-u_- Name: 1,44Ytgc 1ok��4Soe� Mailing Address: C4OOQ 1,44rf- �c E -Mail Address: W A -14 a- S rvx -r> 1't� • r"t Day Telephone: 206,- fZ.� City Fax Number: 2D1• State gob/88 Zip (o2y- 2 ?77 14.1- qt? /t) (o State Zip 62-14 2'173 Company Name: t-1 b j �£ X-M 1 m to Mailing Address: Person: E -Mail Address: Contractor Registration Number: Expiration Date: City Day Telephone:_. Fax Number: State Zip Company Name: 5 .K1 . Mailing Address: Lt O000 4J rtc 2-°(-' '' '. 11 City Contact Person: W j-AE ,Okih -L it- Day Telephone: E -Mail Address: {-4Li7A./ j � . Lop Fax Number: State Lip 24PC•‘2({•2-777 20 6 • 6.'L`f • 2_`?7 Company Name: Mailing Address: Contact Person: E -Mail Address: kVA Q: Wpplications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised: 9 -2006 bh City Day Telephone: Fax Number: Page 1 of 6 State Zip RM`ATION 206=431- 3670" Valuation of Project (contractor's bid price): $ or ,51=0 e $L_ Existing Building Valuation: $ Scope of Work (please provide detailed information): 4,4 ■ L,e)1 4 /3///e./_S DGl% Of Will there be new rack storage? ❑ Yes 1No If yes, a separate permit and plan submittal will be required. 3� 727 ZY/,6 8 R y yye, p7 PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: "Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: ❑ Will there be a change in use? Yes Compact: Handicap: No if "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Spri ers Automatic Fire Alarm ❑ None ❑ Will there be storage or use of amnia le, combustible o�ardous materials in the building? ❑ Yes No If `yes ', attach list of materials and storage locations on a separate 8 -1/2" x I1 " paper including quantities and Material Sy etv Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Other (specify) Q: Applications\Forms- Applications On Line\3 -2006- Permit Application.doc Revised: 9 -2006 bh Page 2 of 6 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: i`!�_�� Date: /'-�c� Print Name: Za-t•-lE 'a. - 0.1- b-.�jt Day Telephone: 2 "G • !62 - 27 % Y P / 7 Mailing Address: ‘7'..0 Do pc2Z,�'64� 4/4 ��y^Z� 5 Z f !I//1¢ City State Zip Date Application Accepted: Date Application Expires: _ t y ,1 Staff Initials: D 1 I i l V On `j V ` I` h. Q:\Applications\Forms- Applications On Line\3 -2006 - Permit Application.doc Revised 9 -2006 bh Page 6 of 6 City of Tukwila ti Department of Community Development a !, 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10-244 Address: 973 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 09/07/2010 Applicant: VACANT SPACE Issue Date: Receipt No.: R10 -02092 Payment Amount: $264.20 Initials: JEM Payment Date: 10/18/2010 10:30 AM User ID: 1165 Balance: $0.00 Payee: BNBUILDERS, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 54028 264.20 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 259.70 640.237.114 4.50 Total: $264.20 doc: Receiot -06 Printed: 10 -18 -2010 L vI11.1A31, City of Tukwila qs, l'..- Department of Community Development 0 6300 Southcenter Boulevard, Suite #100 ,2 0 Tukwila, Washington 98188 Phone: 206-431-3670 'r ' ° Fax: 206 - 431 -3665 `:I 908.x,.: Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: 9202470010 Permit Number: D10-244 Address: 973 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/07/2010 Applicant: VACANT SPACE Issue Date: Receipt No.: R10 -01761 Payment Amount: $168.81 Initials: JEM Payment Date: 09/07/2010 12:26 PM User ID: 1165 Balance: $264.20 Payee: S.M. STEMPER ARCHITECTS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 15608 168.81 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 168.81 Total: $168.81 PAYME ECE1VED doc: Receiot -06 Printed: 09 -07 -2010 NSPECTION RECORD Retain a copy with permit INSPE ON NO. PERMIT NO. "' fLIL• CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206).431 -3670 • Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: t= 1 J l �fA6A _SST?tk6c Add ess: •G'7 -S• 1Ai1 A` i I Date Called: Special Instructions: Date Wanted: l— l l p• • Requester: `�. Phone No: 4...06— g ' Approved per applicable codes. Corrections required prior to approval. . COMMENTS: •d pPlAkoz,N r +-C l4 1t +' f tifstip Insp`E -ir: Date: J 14‘ �i I ii-11),... El PECTION EE REQ IRED. Prior to next to pection, fee. must be aid at 6300 Southcenter B vd.. Suit-' 100. Call to st hedule reinspection. ro. . - - arAoz Nviz9 .'-P'" . r .., ,. : , i s. ••s •. @gym'- a-v. r •'x•5�;.' 'r • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TU_ KWILA BUI.LDING DIVISION 6300 Southcenter Blvd:, #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 110-, it44 Project: Type of Inspection: tm , - • Address: - AM tantaVall Date Called: Special Instructions: • _l- Date Wanted: t�, 1 ® j2, v H O a.m. _ P.m. Requester: , V ,,a Phone No: • — — . • Approved per applicable codes; Corrections required prior to approval. COMMENTS: - • 1 1 (2 AAA^ t KI (, - AM tantaVall t-ot 7.,‘ b....) CI 4-- Ark) triA)44e-fil V6, L \ .d Insp ctor: Date: REIN ° ECTION FEE REQUIRED. Prior to next inspection. fee must be paid a ,300 Southcenter Blvd:;'Suite 100: bit-to schedule reinspection. •■••7•+: 1:.':ra'_'etdr•.•c42E4; • I. Inspector: 1C 63 • Dater � f i i Hrs.. • / - - - — 2 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: r .7... s5 Type of Inspection: _' I r {�"i �1 Ate, Address: 9 73 Suite #: 5, r. 4 ii Contact Person: ; Special Instructions: Monitor: Phone No.: Approved per applicable codes. 1-7 Corrections required prior to approval. COMMENTS: Needs Shift-,Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: • • Occupancy Type: .$80.00 REINSPECTION FEE REQUIRED. You.will receive an invoice from .. the City of Tukwila Finante.Department: Call to schedule a reinspection. Word /Inspection Record Form.Doc 1/13/06 • • T.F.D. Form F.P. 113 ..� `fl': 7.`h`i3n'.+,s.'C?>%Si:•FGS;.v da- l•.T.'.'ev+P+_•irC ":. 1 • f INSPECTION RECORD: Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: pl V A 1 T ' Type o Iospection; i P I h1 kit L Address: C, jj 3 'Suite #: s , (. _ ,eSL t.- Contact Person: Special Instructions: Phone No.: Approved per applicable codes. (Corrections required prior to approval. COMMENTS: Sprinklers; Fire Alarm: Hood & Duct: Monitor: Pre -Fire: l . t ov.c _ E. S. -I i c, R t ivk .e it. vLsAte 1.014/ ) 0),11 ( e) 11k a 1-to 1-1"—(11 Needs Shift Inspection: Sprinklers; Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: 1 ' 8 Hrs:: .. • n $80.00 REINSPECTION•FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule,a reinspection. • Word /Inspection Record 'Form.Doc 1/13/06 T.F.D. Form F.P. 113 *PERMIT COON COPY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D10 -244 DATE: 09/07/10 PROJECT NAME: VACANT SPACE SITE ADDRESS: 973 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ``4� BGild'in Divisions (A it lic Work/A- s (v ire Prevention IN Structural P n laning Division Permit Coordinator q-ko n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 09/09/10 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES /THURS ROUTING: Building Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 10/07/10 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Per Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name B N BUILDERS INC UBI No. 602056687 Phone 2063823443 Status Active Address 2601 4Th Ave Ste 350 License No. BNBUII'990K3 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 5/23/2001 State WA Expiration Date 9/12/2011 Zip 98121 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ociated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WESTESL913K1 WESTERN STATES LOGISTIX LLC Construction Contractor General Unused 5/8/2009 5/8/2011 Active BASTINB0000J BASTIAN NIELSEN BUILDERS INC Construction Contractor General Unused 9/11/2000 9/7/2001 Archived PURODSI984JN PURODI SYSTEMS INC Construction Contractor Plumbing Unused 6/19/2002 7/2/2010 Expired Business Owner Information Name Role Effective Date Expiration Date BASTIAN, BRAD President 05/23/2001 Bond Amount NIELSEN, JEFF Vice President 05/23/2001 6642084 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 INS CO OF AMERICA 6642084 06/02/2009 Until Cancelled $12,000.0006/05 /2009 4 FIRE INS CO 52BSBBK5617 52BSBBK5617 01 /01 /2002 Until Cancelled 06/02/2009 $12,000.0012/04 /2001 3 TRAVELERS CAS & SURETY CO 103355900 08/30/2001 Until Cancelled 04/07/2009 $12,000.00 09/06 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 12 ZURICH AMERICAN INS CO gla380504400 09/07/2010 09/07/2011 $1,000,000.00 09 /07/2010 11 WAUSAU UNDERWRITERS INS. CO TBJZ91442966029 09/07/2009 09/07/2010 $1,000,000.0009 /03/2009 10 WAUSAU BUSINESS INS CO TBKZ91442966028 09/07/2008 09/07/2009 $1,000,000.00 09/05/2008 9 WAUSAU BUSINESS INS CO TBKZ91442966027 09/07/2007 09/07/2008 $1,000,000.00 09/05/2007 https://fortress.wa.gov/lni/bbip/Print.aspx 10/18/2010 WESTFIELD MALL AT SOUTHCENTER TENANT STOREFRONT 973 SOUTHCENTER Code Summary 2212P-.0111±1,613. - WASHINGTON STATE BUILDING CODE - WASHINGTON STATE AMENDMENTS - 2009 INTERNATIONAL BUILDING CODE - 2009 INTERNATIONAL MECHANICAL CODE - 2009 INTERNATIONAL FIRE CODE - 2009 UNIFORM PLUMBING CODE - 2009 WASHINGTON STATE ENERGY CODE - 2009 WASHINGTON STATE VENTILATION AND INDOOR QUALITY CODE FULLY SPRINKLED BUILDING - TO BE SUBMITTED UNDER SEPARATE PERMIT. MECHANICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT ELECTRICAL DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT PLUMBING DESIGN - TO BE SUBMITTED UNDER SEPARATE PERMIT. TENANT IMPROVEMENT - TO BE SUBMITTED UNDER SEPARATE PERMIT. NIS WORK AND ASSOCIATED PERMIT REPRESENTS THE LANDLORD WORK IN PREPARATION FOR FUTURE TENANT. SITE INFORMATION: TENANT SPACE 252 TENANT ADDRESS: 913 SOUTHCENTER TUKWILA, WA 98188 TAX PARCEL NUMBER: 262304 -00I0 ZONING USE: TUC - TUKWILA URBAN CENTER TENANT IMPROVEMENT SUMMARY: TOTAL EXISTING SQUARE FEET: 1,081 S.F. TOTAL REVISED SQUARE FEET: 1,081 SF - NO ADDITIONAL TENANT SQUARE FEET AS PART OF THIS WORK OCCUPANCY GROUP: WESTFIELD MALL - M - COVERED MALL OCCUPANCY LOAD (TABLE 1004.1.1): OCCUPANCY LOAD FACTOR - 30 SF/ 1,081 / 30 = 36 EGRESS REQUIREMENTS: PER TABLE 1015.1 THE MAXIMUM OCCUPANT LOAD FOR ONE EXIT WITHIN OCCUPANCY TYPE 'M' IS 49. (CABLE 1015.1) OCCUPANCY LOAD IS 36 THEREFORE ONE EXIT REQUIRED. TWO EXITS ARE PROVIDED THEREFORE OK MINIMUM CORRIDOR WIDTH OF 44" - EXISTING AND PROVIDED, THEREFORE ACCEPTABLE EGRESS WIDTH - 36 (2) = 1.2 INCHES - PAIR OF 36" WIDE DOORS SHALL BE PROVIDED AT MALL STOREFRONT AND EXISTING EXIT DOOR TO BACK OF HOUSE CORRIDOR IS 36" WIDE - THEREFORE OK TABLE 1016.1 - OCCUPANCY M MAXIMUM TRAVEL DISTANCE WITH SPRINKLER SYSTEM IS 250 FEET. TRAVEL DISTANCE WITHIN TENANT SPACE IS LESS THAN 250 - THEREFORE OK SECTION 402.4.4 - WITHIN EACH INDIVIDUAL TENANT SPACE IN A COVERED MALL, THE MAXIMUM TRAVEL DISTANCE FROM ANY POINT TO AN EXIT OR ENTRANCE TO THE MALL SHALL NOT EXCEED 200 FEET. TRAVEL DISTANCE TO EXITS FROM WITHIN TENANT SPACE IS LESS THAN 200 FEET THEREFORE OK FIRE RESISTANCE REQUIREMENTS: SECTION 402.4.5.1 WHERE DOORWAYS TO EXITS PASSAGEWAYS SHALL 8E PROTECTED BY 1 -14OUR FIRE DOOR ASSEMBLY THAT IS SELF CLOSING BY SMOKE DETECTION IN ACCORDANCE WITH SECTION 115.483. SECTION 402.12 - EACH TENANT 51-1ALL BE SEPARATED BY A FIRE PARTITION IN ACCORDANCE TO SECTION 109. CONTRACTOR SHALL COORDINATE WITH BUILDING INSPECTOR FOR STAGGERING OF GYPSUM WALL BOARD ON TENANT DEMISING WALLS THAT HAVE PREVIOUSLY INSTALLED GYPSUM WALL BOARD INSTALLED ON ADJACENT TENANTS DEMISING WALL General Notes I. ALL WORK TO 8E PERFORMED IN COMPLIANCE WITH ALL APPLICABLE CODES, LAWS AND REGULATIONS OF ALL AUTHORITIES HAVING JURISDICTION OVER THE WORK 2. CONTRACTOR TO VERIFY ALL DIMENSIONS, PROPERTY LINES, LEASE LINES, MEASUREMENTS AND CONDITIONS IN THE FIELD BEFORE BEGINNING WORK ANY DISCREPANCIES, ERRORS OR OMISSIONS TO BE BROUGHT TO THE ATTENTION OF NE ARCHITECT IMMEDIATELY. 3. THE ARCHITECT WILL WAVE A REPRESENTATIVE ON SITE, AT SCHEDULED MEETINGS AND SITE VISITS TO OBSERVE THE CONSTRUCTION FOR COMPLIANCE WITH THE DESIGN INTENT AND TO ASSIST THE CONTRACTOR IN RESOLVING VARIATIONS IN THE EXISTING CONSTRUCTION. THESE DOCUMENTS ADDRESS ALL KNOWN CONDITIONS, BUT IT IS ANTICIPATED THAT HIDDEN CONDITIONS WILL BE ENCOUNTERED DURING CONSTRUCTION. THE ARCHITECT WILL OBSERVE ALL SUCH HIDDEN CONDITIONS AND ISSUE CLARIFICATIONS OR MODIFICATIONS OF THE DESIGN TO ADDRESS SUCH CONDITIONS AND WILL DOCUMENT ALL CHANGES. 4. UNLESS OTHERWISE NOTED, ALL ANGLES TO BE RIGHT ANGLES, ALL LINES WHICH APPEAR PARALLEL ARE TO BE PARALLEL, AND ALL ITEMS WHICH APPEAR CENTERED ARE TO BE CENTERED. CONTRACTOR TO BE RESPONSIBLE FOR MAINTAINING ALL LINES TRUE, LEVEL, PLUMB AND SQUARE. 5. DETAILED AND /OR LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER GENERAL AND SMALLER SCALE DRAWINGS. POSTED DIMENSIONS WILL TAKE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL NOT SCALE DRAWINGS FOR DIMENSIONS. 6. ALL ATTACHMENTS, CONNECTIONS AND FASTENINGS OF ANY NATURE ARE TO BE PROPERLY AND PERMANENTLY SECURED IN CONFORMANCE WITH THE BEST PRACTICES OP THE BUILDING INDUSTRY. DRAWINGS 51-1OW ONLY SPECIAL REQUIREMENTS TO ASSIST THE CONTRACTOR AND DO NOT 51-10W EVERY DETAIL. 1. DETAILS SHOWN IN THESE DRAWINGS ARE TYPICAL AND WILL APPLY UNLESS OTHERWISE NOTED OR SHOWN. DETAILS OF CONSTRUCTION NOT FULLY SHOWN ARE TO BE OF THE SAME NATURE AS THOSE DRAWN FOR SIMILAR CONDITIONS. 8. CONTRACTOR TO PROTECT EXISTING FURNISHINGS, . FIXTURES, EQUIPMENT AND LANDSCAPING FROM DAMAGE. CONTRACTOR TO REPLACE IN KIND ANY SUCH ITEMS DAMAGED, IN ITS ENTIRETY TO LEVEL OF SATISFACTION OF ARCHITECT. 9. CONTRACTOR TO COORDINATE ALL OPERATIONS WITH OWNER, INCLUDING: SITE ACCESS, MATERIALS STORAGE AND STAGING, INTERRUPTION OF ELECTRICAL AND MECHANICAL SERVICES AND TIMING OF NOISY OR DISRUPTIVE OPERATIONS. CONTRACTOR TO VERIFY SEQUENCE OF WORK WITH OWNER. 10. ALL INTERIOR GWS IS i" TYPE X ON METAL STUDS OR FURRING CHANNELS UNLESS NOTED OTHERWISE, SIZES AS DIMENSIONED ON PLANS. SEE NOTE FOR WATER RESISTANT GWB. 11. PROVIDE WATER RESISTANT (PAPERLESS) TYPE X GWB IN ALL TOILET ROOMS, WAREWASH AND WET AREAS. 12. PROVIDE FINISH WALL BEHIND ALL EQUIPMENT AND CASEWORK 13. PROVIDE ALL ACCESSIBLE SIGNAGE AS REQUIRED BY LOCAL OR APPLICABLE JURISDICTION. 14. PROVIDE ONE TYPE 5E-2A-1013C FIRE EXTINGUISHER PER 3000 SF AND NOT MORE THAN 15 FT OF TRAVEL DISTANCE, 15. THERE SHALL BE NO BACK -TO -BACK ELECTRICAL, TELEPHONE, OR OTHER OUTLETS. SEPARATE OUTLETS BY 6" At AT NONRATED PARTITIONS. SEPARATE OUTLETS BY 24" MIN. AT FIRE RATES PARTITIONS. 16. WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL, AND PLUMING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND /OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE STOP MATERIAL. 11. PROVIDE EXIT ILLUMINATION PER LOCAL CODES. 18. FURNISH AND INSTALL THE FIRE PROTECTION SYSTEM TO ACCOMMODATE THE CONFIGURATION INDICATED ON TI4E PLANS. COMPLY WITH ALL GOVERNING ORDINANCES AND LANDLORD CRITERIA. CONTRACTORS SHALL OBTAIN ALL NECESSARY PERMITS. 19. INSTALL FIRE ALARM SYSTEMS TO COMPLY WITH LANDLORD CRITERIA AND LOCAL CODES AS REQUIRED. 20.FIRE SPRINKLER SYSTEM WORK AND FIRE ALARM SYSTEM WORK IS TO BE SUBMITTED UNDER SEPARATE PERMITS. Scope of Work SCOPE OF WORK SHALL INCLUDED TI4E LANDLORD BUILD OUT OF TENANT IMPROVEMENT TO AN EXISTING VACANT SPACE WITHIN WESTFIELD MALL AT SOUTHCENTER IN PREPARATION FOR FUTURE TENANT. WORK SHALL INCLUDE, BUT NOT BE LIMITED TO: - CONSTRUCTION OF NEW TENANT MALL STOREFRONT - CONSTRUCTION OF NEUTRAL PIERS AT TENANT MALL STOREFRONT Drawing Index ARCHITECTURAL TO.0 TITLE - COVER SHEET A1.0 FLOOR PLAN, WALL SECTION, ELEVATION, AND DETAILS Separate Permits THE FOLLOWING ITEMS SHALL BE UNDER SEPARATE PERMIT SUBMITTED BY CONTRACTOR OR TENANT: - INTERIOR TENANT IMPROVEMENT - FIRE ALARM - FIRE SPRINKLER - MECHANICAL - ELECTRICAL - PLUMBING MPROVEMENTS REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may Include additional plan review fees. RAT i. PERMIT CIEQUUIRED FOR: I echanical ElhiEpectrical Plumbing fas Piping City of Tukwila BUILDING DIVISION Project Directory WEA SOUTHCENTER, LLC 2800 Southcenter Seattle, W,4 9SISS SENIOR GENERAL MANAGER: ANDREW CIARROCHI T - 206246.0423 F - 206244.8601 MALL OPERATIONS: PAT BUR 15 T - 206246.0423 F - 206244.8601 C - 206.186.9011 PBURNSeWESTFIELD.COM ARCHITECT SM. STEMPER ARCHITECTS, P11.C. 4000 Delridge Way SW Suite 200 Seattle, Washington 98106 CONTACT: WAYNE JOHNSON, PROJECT MANAGER (206) 624 -2111 (206) 624 -2913 FAX wayneesmstemper.com FILE COPY Permit No. ttO 2411 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Figid Copy and conditions is acknowledged: By Date:.l ® /l-el1 City Of Tukwila BUILDING DIVISION Site Plan 3 LEVELS n 1 TENANT SPACE 973 SOUTHCENTER REVIEWED FOR CODE COMPLIANCE APER M/ED SEP 15 2U10 WYE /1.5 -City of Tukwila BUILDING nIVISION mervyiivs 2 LEVELS I Mar NORDSTROM I kill; 111 111111 ❑ ❑ I I 1 1 1 1 JCPenney 3 LEVELS 3 LEVELS 1 CITYEOFE1SLA SEP Q.7 2010 PERMIT CENTER 1) 0) 16"."141 Wesiliek! Southcenter 633 Southo nt.r Parkway TIM .% WA., 98188 -2888 208 - 248 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 THIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. AU. DESIGN AND OTHER INFORMAPON SHOWN ON THE DRAWNG ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 1- z Cw w(i) >z i_ < U F- 0 z -J 0 u) c tl O j z z w ISSUE DC � w H co Z W 0 J c� Y rn ISSUE PERMIT SET DATE: SEPT. 3, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ TITLE - COVER SHEET T0.0 SMSA #1022.11 TOP OF BULKHEARP I5, -6" 4) TOP OF STOREFRONT 13' -I0" BOTTOM OF MULLION I0' -0" f I I I I ■ I LEASE LINE _ I PAIR OF STOREFRONT DOORS - TYPICAL DOOR HARDWARE - SEE SCHEDULE 0' -0�' FINISH FLOOR DEMO (E) FINS BREAK METAL SHAPE e T.O. STOREFRONT FRAME METAL STUD AND GWB SOFFIT. LEVEL 4 FINISH )6" THICK GLAZING - TEMPERED BUTT GLAZED AT VERTICALS DOOR WITH* GLAZING STOREFRONT SECTION 1/2" = 1' -0" TOP OF STOREFRONT ADJACENT TENANT BULKHEAD / STOREFRONT BOTTOM OF MULLION 10' -0" GWB NEUTRAL PIER TO BE PAINTED - LEVEL 4 FINISH (E) 1/2" RECESSED METAL REVEAL TO REMAIN MALL CONCOURSE (E) FLOORING TO REMAIN Z: I BREAK METAL SHAPE B • ULKHEAD w I —1 I$. EXISTING CORRIDOR 101 n'-e" 33' -1" 2' -6" CO) (E) DOOR TO REMAIN (E) STEEL COLUMN TO REMAIN (E) STEEL COLUMN TO REMAIN LEASE LINE (E) STEEL COLUMN TO REMAIN (E) VACANT TENANT SPACE - NO WORK THIS AREA (E) TENANT DEMISING WALL TO REMAIN VACANT TTEENANT 100 (E) TENANT DEMISING WALL TO REMAIN 100) 1 LEASE LINE EXISTING MALL CONCOURSE BULKHEAD - FIELD VERIFY HEIGHT BOTTOM OF (E) BULKHE 13' -I0" GWB NEUTRAL PIER TO BE PAINTED - LEVEL 4 FINISH 1/2" RECESSED METAL REVEA (BRUSHED ALUMINUM 12" HIGH STONE TILE BASE - OFCI FINISH FLOOR 01 -0" STOREFRONT ELEVATION 1 /4" = 1' -0" (E) FRAMING AND GWB AT ADJACENT TENANT (E) TENANT DEMISING WALL LEASE LINE (E) 1/2" RECESSED METAL REVEAL TO REMAIN 1/2" RECESSED METAL REVEAL (BRUSHED ALUMINUM ADJACENT TENANT BULKHEAD AND STOREFRONT 12" 1-11G14 STONE TILE BASE OFCI ADJACENT TENANT STOREFRONT INTERIOR FINISH BY TENANT 35/" METAL STUD FRAMING AND GWB - PAINT TO LEVEL 4 FINISH LEASE LINE J DOOR NO ROOM LOCATION DOOR TYPE DOOR STYLE SIZE W x H THK. DOOR MATL. HM FR. TYPE FRAME MATL. RATING DETAILS HDWR GROUP NOTES FIRST FLOOR HEAD JAMB THRESH 100 COMMON MALL - RETAIL AREA N/A GLASS PR 3' -0" x 10-0" 1/2" GLASS N/A N/A N.R. 2,3 2,3 2,3 1 2, 3, 4, 5 101 VACANT SPACE - CORRIDOR EXISTING 3' -0" x T -0" I -HR 1 REMARKS ABBREVIATIONS 1. EXISTING DOORS ARE TO REMAIN - NO MODIFICATIONS TO DOORS OR FRAMES AL ALUMINUM 2: FURNISH AND INSTALL TILE TO MALL CONCOURSE TILE TO LEASE LINE FL FLUSH DOOR 3. GLASS DOORS SHALL BE CLEAR FULLY TEMPERED SAFETY GLASS MEETING ALL REQUIREMENTS FOR GLASS FR FRAME DOORS INCLUDED ADJACENT BORROWED LITES. HM HOLLOW METAL 4- PULLS TO BE STAINLESS STEEL NR NON -RATED 5. DOORS TO HAVE SIGN (I" HIGH LETTERS) LOCATED ABOVE DOORS WITI-IIN VACANT SPACE STATING "THIS STOR STOREFRONT DOOR TO REMAIN UNLOCKED WHEN BUILDING 16 OCCUPIED" WD DOOR WOOD (E) 12" HIGH STONE BASE TO REMAIN (E) GLUES TO REMAIN (E) REVEAL TO REMAIN GWB AT NEUTRAL PIER - PAINT TO MATCH MALL CONCOURSE - LEVEL 4 FINISH (EXTEND TO BOTTOM OF SOFFIT) =I-WO TO FINS AT TOP•OF • NEUTRAL PIER AND TENANT STOREFRONT AND PATCH GWB )4" REVEAL - BRUSHED ALUM GLOB - PAINT TO MATCH MALL CONCOURSE LEVEL 4 FINISH )4" MAX. GAP AT WALL NEUTRAL PIER DETAIL 1 1 /2" = 1' -0" 12" HIGH STONE BASE STOREFRONT FRAME AND GLAZING - ALIGN TO LEASE LINE )9 MAX. GAP AT CORNER 3 %u' METAL STUD FRAMING AND GM - PAINT TO LEVEL 4 FINISH INTERIOR FINISH BY TENANT k 0 .0 )6" MAX GAP AT WALL LEASE LINE (E) TENANT DEMISING WALL (E) FRAMING AND GWB AT ADJACENT TENANT 12" HIGH STONE BASE GIUB - PAINT TO MATCH MALL CONCOURSE LEVEL 4 FINISH )6" REVEAL - BRUSHED ALUMINUM GM AT NEUTRAL PIER - PAINT TO MATCH MALL CONCOURSE - DEMO (E) FINS AT TOP OF NEUTRAL PIER AND TENANT STOREFRONT AND PATCH GWB (E) REVEAL TO REMAIN (E) 12" HIGH STONE BASE TO REMAIN (E) GWB TO REMAIN ADJACENT TENANT STOREFRONT NEUTRAL PIER DETAIL 1 1 /2" = 1' -0" )$" MAX. GAP AT WALL STOREFRONT FRAME AND GLAZING - ALIGN TO LEASE LINE LEASE LINE NOTES: 1. DIMENSIONS PROVIDED ARE PLUS/MINUS DIMENSIONS TO BE COORDINATED WITH EXISTING PARAMETERS. CONTRACTOR SHALL VERIFY EXISTING AND NEW DIMENSIONS AND NOTIFY ARCHITECT OF ANY DISCREPANCIES. 2. WALL TYPES SHALL EXTEND UP TO BOTTOM OF SUSPENDED CEILING TILES UNLESS NOTED OTHERWISE IN WALL TYPES. 3. EXISTING WALLS ADJACENT TO TENANT SPACE SHALL REMAIN - LEAVING MIN. 6" GAP AT TOP OF WALL FOR PROPER PLENUM AIR FROM FINISH WALL PER FINISH SCHEDULE. 4. DATA/ELECTRICAL ARE SHOWN FOR REFERENCE ONLY. ELECTRICAL DESIGN SHALL BE SUBMITTED BY CONTRACTOR AND PERMITTED UNDER SEPARATE PERMIT. 5. ALL MATERIALS SHALL BE NON - COMBUSTIBLE AND /OR SHALL COMPLY WITH THE REQUIRED FLAME SPREAD OR SMOKE DEVELOPED INDEX FOR TYPE II CONSTRUCTION. ALSO ANY WOOD COMPONENTS USED SHALL BE FIRE RETARDENT TREATED WOOD. (IBC 402.15.4, 602, 603, 4 2604) 6. CONTRACTOR 51-1ALL VERIFY EXISTING CONDITIONS AS WELL AS LEASE LINES PRIOR TO CONSTRUCTION ANY DESCREPENCIES SHALL BE BROUGHT TO THE ATTENTION OF WESTFIELD FOR CLARIFICATION. 7. CONTRACTOR SHALL PROTECT MALL COMMON AREA AT ALL TIMES AND NO CONSTRUCTION MATERIAL, DEBRIS, WORK, OR DUST SHALL ENTER OR BE WITHIN MALL COMMON AREA. HARDWARE GROUPS GROUP 1 - GLASS DOOR 100 2 QTY. OVERHEAD CONCEALED CLOSER (CRL) 2 FRS. I" DIA. IS" BACK TO BACK PULLS (CRL GLASS MOUNTED STRAIGHT) 2 QTY. DEAD BOLT FLOOR RAIL LOCK (CRL POOR FLOOR RAIL LOCK) 2 QTY. CYLINDER (CRL MORTISE KEYED CYLINDER) FINISH OF HARDWARE AND STILES SHALL BE BRUSHED STAINLESS STEEL MALL STOREFRONT STOREFRONT DESCRIPTION - EXTRUDED SADDLE TYPE FRAME AT HORIZONTAL MULLIONS, SILL AND HEAD - SILL SHALL BE 6)6" HIGH - MULLION SHALL BE 4 1/2" HIGH - HEAD SHALL BE 4 1/2" - FRAME FINISH SHALL BE BRUSHED STAINLESS STEEL - VERTICAL JOINTS IN STOREFRONT SHALL BE )9 WIDE MAXIMUM - BUTT GLAZED SYSTEM ALIGN FINISHES 1 4/- 1' -6 3/4" DEMO (E) FINS AT BULKHEAD - TYPICAL REVIEWED FOR CODECOMPLIANCE COMPLIANCE \- APDI A ED SEP i 5 2010 City of Tukwila BUILDING nwvIRInN BULKHEAD DETAIL 1 1 /2" = 1' -0" 4" LEASE LINE BREAK METAL SHAPE e MATCH STOREFRONT FRAME METAL STUD AND GWB. LEVEL 4 FINISH BOTH SIDES STOREFRONT FRAMING crtvRORRu SEP Q.7 2010 P&RMITCENTER 13siI1ebf Southcenter 633 Sauthonter Parkway lbkwa, WA., 98188 -2868 208 -246 -0423 WESTFIELD DESIGN & CONSTRUCTION 11601 Wilshire Boulevard, 11th Floor Los Angeles, California 90025 -1748 Telephone 310 478 4456 Facsimile 310 478 4468 1HIS DRAWING IS AN INSTRUMENT OF SERVICE, IS THE PROPERTY OF THE ARCHITECT AND MAY NOT BE REPRODUCED WITHOUT THE ARCHITECT'S PERMISSION AND UNLESS THE REPRODUCTION CARRIES THE ARCHITECT'S NAME. AU. DESIGN AND OTHER INFORMATON SHOWN ON THE DRAWING ARE FOR USE ON THE SPECIFIED PROJECT ONLY AND SHALL NOT BE USED OTHERWISE WITHOUT WRITTEN PERMISSION FROM THE ARCHITECT S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98108 (200) 624 -2777 • FAX (206) 624 -2973 1-- z w w >z - U z O u- 0 0 z z w 1— ISSUE ISSUE PERMIT SET DATE: SEPT. 3, 2010 PROJECT ARCHITECT WEJ PROJECT MANAGER WEJ FLOOR PLAN WALL SECTION ELEVATION AND DETAILS A1.0 SMSA #1022.11