Loading...
HomeMy WebLinkAboutPermit D11-108 - HITCHCOCK RESIDENCE - IMPROVEMENTHITCHCOCK RESIDENCE 11650 44 AV S D11 -108 City oilii'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 3347400650 Address: 11650 44 AV S TUKW Suite No: Project Name: HITCHCOCK RESIDENCE DEVELOPMENT PERMIT Permit Number: D11 -108 Issue Date: 06/24/2011 Permit Expires On: 12/21/2011 Owner: Name: HITCHCOCK DOUGLAS R Address: 15307 SE 43RD PL , BELLEVUE WA 98006 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Contractor: Name: CADENCE CONSTRUCTION INC Address: 5821 S FLETCHER ST , SEATTLE WA 98118 Contractor License No: CADENCI915JB Phone: 206 - 296 -7437 Phone: 206 - 355 -8340 Expiration Date: 04/05/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING: SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Construction: $23,292.80 Fees Collected: $905.73 Type of Fire Protection: NONE International Building Code Edition: 2009 Type of Construction: V -B Occupancy per IBC: 0022 Electrical Service Provided by: * *continued on next page ** doc: IBC -7/10 011 -108 Printed: 06 -24 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Water Meter: N Permit Center Authorized Signature: Private: Public: [P—IN Date: le- 02 4v1J I hereby certify that I h ve read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work w 11 be complied with, whether specified herein or not. The granting of t construction or to this permit. Signature: Print Name: rmit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating rformance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached Mt %V ASS vl Date: 4 f This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional m responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D11 -108 Printed: 06 -24 -2011 this requirement. • • 7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D11 -108 Printed: 06 -24 -2011 CITY OF TUKWIL>♦ Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://ivww.ci.tuk-wila.wa.us Building Per No. 1)11.. L 0 • Mechanical Permit No. Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Dg to, 03, L 1-91 Site Address: 11650 44th Avenue S. Tenant Name: Douglas R. Hitchcock King Co Assessor's Tax No.: 3347400650 Suite Number: New Tenant: Property Owners Name: Douglas R. Hitchcock Mailing Address: 11650 44th Avenue S. Floor: ❑ Yes ® ..No 98178 Seattle WA City State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South E -Mail Address: Sharyn.Parker @kingcounty.gov Day Telephone: (206) 296 -7437 Seattle WA 98108 City • State Fax Number: (206) 269 -7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: Expiration Date: State Zip ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Melody Leung or Timothy Fenlason E -Mail Address: melody @smstemper.com or tim @smstemper.com City State Day Telephone: (206) 624 -2777 Fax Number: (206) 624 -2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: H:WpplicationsWorms- Applications On Line\2009 Applications\I -2009 - Permit Application.doc Revised: 1 -2009 bh State Zip Page 1 of 6 BUILDING PERMIT INFORM[ON — 206 -431 -3670 • Valuation of Project (contractor's bid price): $ — 24,212 2 3 i Z01Z tBo Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Applications' Forms- Applications On Line 2009 Applications, I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 • Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l st Floor 1,100 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8 -1/2 "x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Applications' Forms- Applications On Line 2009 Applications, I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 2 of 6 • PUBLIC WORKS PERMIT INF ATION — 206 -433 -0179 • Scope of Work (please provide detailed information): Call before you Dig: 1- 800 - 424 -5555 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ...Valley View ❑ .. Renton ❑ ... Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34 ") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right -of -way Use - Nonprofit for less than 72 hours ❑ ...Right -of -way Use - No Disturbance ❑ ...Construction /Excavation /Fill - Right -of -way ❑ Non Right -of -way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ ...Sanitary Side Sewer ❑ ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑...Traffic Impact Analysis ❑ ... Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) ❑ .. Right -of -way Use - Profit for less than 72 hours ❑ .. Right -of -way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ .. Abandon Septic Tank ❑ .. Curb Cut ❑ .. Pavement Cut ❑ .. Looped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size.. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑...Water Main Extension Public ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO# WO# WO # ❑ ... Deduct Water Meter Size Private ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications \Forms - Applications On Line \2009 Applications \I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 3 of 6 MECHANICAL PERMIT INF ATION — 206 - 431 -3670 MECHANICAL CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Mechanical work (contractor's bid price): $ Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... ❑ Commercial: New .... ❑ Replacement .... ❑ Fuel Type: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler /Compressor: Qty Furnace <100K BTU Air Handling Unit >10,000 CFM Fire Damper 0 -3 HP /100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3 -15 HP /500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15 -30 HP /1,000,000 BTU Suspended/Wall /Floor Mounted Heater Ventilation System Wood/Gas Stove 30 -50 HP /1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP /1,750,000 BTU Repair or Addition to Heat/Refrig /Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator— Comm /Ind H :Applications Forms- Applications On Line:2009 Applications`. I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 4 of 6 PLUMBING AND GAS PIPING•RMIT INFORMATION — 206 - 431'0 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Intl Building Code): Occupancy (per Intl Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H:\Applications \Fortes- Applications On- LinM2009 Applications\ 1 -2009 Permit Application.doc Revised: 1 -2009 bh Page 5 of 6 PERMIT APPLICATION NOTES - Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER I ' ; = ORIZED AGENT: Signature: Date: 2- *2o m Print Name: YiA i7t 5 r ) LA6 ° N Day Telephone: 2476 -�0 4-`�C - 2-11+ Mailing Address: 4WQ Pe cr vJ I 290 �� \F-A-- ti 06 City State Zip Date Application Accepted: Date Application Expires: Staff Initials: H: Applications :Forms- Applications On Line'2009 Applications•.I -2009 - Permit Application.doc Revised: 1 -2009 bh Page 6 of 6 41 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us Parcel No.: 3347400650 Address: 11650 44 AV S TURIN Suite No: Applicant: HITCHCOCK RESIDENCE RECEIPT Permit Number: D11 -108 Status: PENDING Applied Date: 04/25/2011 Issue Date: Receipt No.: R11 -00851 Initials: User ID: TLS 1670 Payment Amount: $905.73 Payment Date: 04/29/2011 08:56 AM Balance: $0.00 Payee: KING COUNTY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 024034 ACCOUNT ITEM LIST: Description 905.73 Account Code Current Pmts BUILDING - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $905.73 546.20 355.03 4.50 doc: Receiot -06 Printed: 04 -29 -2011 r.• • } 1' INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. fiL CITY OFTUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 -Permit Inspection Request Line (206) 431 -2451 Proct: fr_1 CO (JJC 4—i Type of Inspection: c: Ai A-c (0 •'A-6 Address: . / i (05 0 4 ~Avg_ r Date r ed �.. ----, Special Instructions: Date Wanted:. �- aa..m.. "- L (p — (i p.m. Requester: Phone No: J 16 Approved per applicable codes. COMMENTS: ElCorrections required prior to approval. r er Ai :7"--Z/0 AdV 637 3- Ilnsector: • IDatie:o - -ft n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • PE PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: 011 -108 DATE: 04 -29 -11 PROJECT NAME: HITCHCOCK RESIDENCE SITE ADDRESS: 11650 44 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: c 05,0c. P \\p (` 9 11 building Division Fire Prevention P " u IIC Wor s Structural N IA cg-•p3 l l Planning Division ION Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 05-03-11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES /THURS ROUTING: Please Route IT Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05-31-11 Approved n Approved with Conditions tt Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Painter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name CADENCE CONSTRUCTION INC UBI No. 602882989 Phone 2063558340 Status Active Address 5821 S. Fletcher Street License No. CADENCI915JB Suite /Apt. License Type Construction Contractor City Seattle Effective Date 4/2/2009 State WA Expiration Date 4/5/2013 Zip 98118 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status CADENC'971K2 CADENCE CONSTRUCTION Construction Contractor General Unused 5/22/2003 8/9/2009 Expired Business Owner Information Name Role Effective Date Expiration Date NISSINEU, KIMMO JOACHIM President 04 /02/2009 Amount KELLEY, KATIE ANN Vice President 04 /02/2009 CGL000758622 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 DEVELOPERS SURETY & INDEM CO 799434C 03/18/2009 Until Cancelled $12,000.00 04/02/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 BERKLEY REGIONAL SPECIALTY INS CGL000758622 11/26/2010 11/26/2011 $1,000,000.0011/03/2010 1 BERKELY REGIONAL SPECIALTY INS CGL000758622 11/26/2008 11/26/2010 $1,000,000.0010/27/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print. aspx 06/24/2011 KING COUNTY INTERNATIONAL AIRPORT RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - 000624C1 1 BID PACKAGE S -23 5- 53- 0058 -043 FILE COPY Permit Not 17U —10/ ` b , Plan review approval is subject to errors and omissions. Approval of con documents does not authorize the violation of : y adopted code or ordinance. Receipt of approved F , Copy and conditions is acknowledged: BY Date , -"z-1 Zd City Ofibbvtta BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Iumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review, fees. SITE AND BUILDING INFORMATION ,JURISDICTION: Department of Planning and Development City of Tukwila, WA APPLICABLE CODES: 2009 International Residential Code, International Fire Code, International Mechanical Code Washington State Energy Code ZONINCs: 8F1200 OCCUPANCY: (No Change) SINGLE FAMILY RESIDENCE. CONSTRUCTION TYPE: (No Change) Y B NON SPRINKLERED BUILDING AREA: No change to building footprint. Addition:. Remodel: Sound Insulation: CODE FOR E COMPLIANCE ti APPROVED MAY 10 2011 C yof u IIa BUILDING ISiow DRAWING INDEX T0.0 AI.0 A2.0 A2.1 A22 .423 TITLE SHEET, PROJECT INFO. FLOOR PLANS 4 NOTES WINDOW TYPES, SCHEDULE t DETAILS DOOR TYPES, SCHEDULE 4 DETAILS MISCELLANEOUS DETAILS WINDOW FLASHING DETAILS M1.0 LEGENDS, SCHEDULES, ABBREY, GENERAL NOTES 4 DWG INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS E1.0 ELECTRICAL PLAN PROJECT DIRECTORY KING COUNTY INTL. AIRPORT: Sound Insulation Program King County International Airport 1211 Perimeter Road South Seattle WA 98108 Ph: 206. 263. 9233 Fax: 206.296.0190 Contact: Sharyn Parker E- mail: Sharyn.Parker*kingcounty.gov ARCHITECT: SM. Stamper Architects PL.L.C. 4000 Delridge Way SW, Suite 200 Seattle, WA 98106 Ph: 206. 624. 2111 Fax: 206.624.2913 Contact: Jerry Osborn, Melody Leung, Tim Paella son, E -mail: Jerryesmstemper.com melodyesmstempercom timesmstemper.com ACOUSTICAL ENGINEER SSA Acoustics 222 Etruria Street, Suite 100 Seattle WA 98109 Ph: 206. 839. 0819 Fax: 206.839.0824 Contact: Mohamed Ait Allaoua E -mail: mohamedenssaacousticscom MECHANICAL ENGINEER The Greenbusch Croup 1900 West Nickerson St., Suite 201 Seattle, WA 98119 Ph: 206. 318. 0569 Fax: 206.318.0641 Contact: Chris Agar E -mail: ChrisAegreerbuschcom ELECTRICAL ENGINEER: Tres West Engineers 2102 S. 42nd Street, Suite 301 Tacoma, WA 98409 Ph: 253. 412. 3300 Fax: 253.412.3463 Contact: Brent Rollins E -mail: bcretreswestcom REGULATED MATERIALS: PBS Engineering and Environmental 2511 Eastlake Ave. E., Suite 100 Seattle, WA 98102 Ph: 206. 232. 9639 Fax: 206.162. 4180 Contact: Tim Ogden E -mail: tim ogden*pbsenvcom DESIGN SUPPORT SERVICES The Jones Payne Group 123 North Washington St. °200 Boston, MA 02114 Contact: Tim Fenlason/ Jim Cornwell E -mail: JCornwelle.lonespayne.com VICINITY MAP RECEIVED APR 29 2011 PERMTCENTER bLl(O3 s.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 0810.03.1731 2/24/11 0 0 ce J z 0 z w z z 0 0 C7 z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 z 0 z DATE 2/24/11 ISSUED BID PACKAGE S -23 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA LB &JH PROJECT INFORMATION, DRAWING INDEX, VICINITY MAP DIRECTORY T0.0 0810.03.1731 20" x 28" EXIST ATTIC ACCESS PANEL NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTION 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTION 01011 AND 02081 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM PAINT. MAIN FLOOR PLAN 1/4" = 1' NOTE: NTERIOR TRIM TO BE FINISHED TO MATCH EXISTING GENERAL NOTES 1 CONTRACTOR TO PROTECT OWNERS' FURNITURE AND POSSESSIONS FROM DAMAGE AND DUST. 2. CONTRACTOR TO TEMPORARILY REMOVE FURNITURE, CONTENTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK OF THESE DOCUMENTS AND RETURN THEM TO THEIR ORIGINAL LOCATIONS AT THE COMPLETION OF WORK DAILY. 3. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED. 4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOMS. 5. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE FOR WEEKENDS. 6. DOORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL AND REPLACEMENT OF A DOOR AND /OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN 8:00 AM AND 5:00 PM. 1. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT. 8. ALL WORK AREAS SHALL BE BROOM- CLEANED AT THE END OF EACH WORK DAY. 9. PANELS, DUCTS 4 SWITCHES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL. 10. WHERE SOFFITS AND /OR MECH. COMPONENTS INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS REQ'D AND RE- CONSTRUCT SHELVING IN COORDINATION WITH SOFFITS AND /OR MECHANICAL COMPONENTS. RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION, MATERIALS, AND FINISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SHELVING 50 AS NOT TO INTERFERE WITH THE OPERATION OF MECHANICAL UNIT ACCESS HATCHES. 11. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS. 12. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR.. THERE ARE SEVERAL GRADES OF TEXTURE AND DENSITY OF CEILING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT NE PROJECT LOCATION. REPLACEMENT FINISH COAT SYSTEMS ARE TO MATCH THE ADJACENT (E) FINISH COAT. 13. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AI.0 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. SEE ELECTRICAL 3HCET EL0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. 14. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE. 15. MAXIMUM POWER OUTAGE I9 EIGHT HOURS POWER MUST BE PROVIDED AT RESIDENCE BEFORE &00 AM. 4 AFTER 5:00 It 16. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK REFER TO ELECTRICAL FOR TIMER LOCATION 11. CONTRACTOR IS TO VERIFY THAT THERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND WORKING CLEARANCES FOR THE MECHANICAL EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR N FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISHES. COORDINATE WITH MECHANICAL. 18. DO NOT INSTALL NEW DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENINGS ARE DETERIORATING, (EG: WOOD ROT, TERMITE DAMAGE) CONTACT TECHNICAL REPRESENTATIVE IF DETERIORATION I5 UNCOVERED. 19. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE NOT AVAILABLE, OR INSTALLATION AND /OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE PROVIDED. 291-2" / ■ \ / / 7 / / \ \ \ / / / \ 20" x 28" EXIST / _ _ _ _\ ATTIC ACCESS - - - PANEL _ /" / I /RAISE INSULATION- / - CURS - WEIGHT AT - _ / _ EXIST. Attic / ACCESS PANEL 25' -2" ATTIC PLAN 1/4" = 1' PLAN KEYNOTES ODEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF. WINDOW SCHEDULE ON SHEET 42.0 ODEMOLISH EXISTING DOOR(S), FRAME, CASING, AND THRESHOLD. INSTALL NEW EXTERIOR DOOR FRAME, CASING, AND STORM DOOR. REF. DOOR SCHEDULE ON SHEET A2.1 ODEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. I /A22 FOR DETAIL. COORDINATE WITH MECHANICAL. OINSTALL FIREPLACE VENT, COORDINATE EXACT LOCATION WITH HOMEOWNER. OINSTALL FIREPLACE CAP AT (E) CHIMNEY TOP LOCATION SERVING MASONRY FIREBOXES. ANCHOR CAP IN OPEN POSITION. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION. DO NOT INSTALL DAMPERS AT CHIMNEY TOPS SERVING METAL FIREBOXES. OINSTALL ROOF MOUNTED BAFFLE TO (E) KITCHEN EXHAUST REF. 3/A42 FOR DETAIL c:: INSTALL NEW THERMOSTAT: COORDINATE WITH MECHANICAL. gO INSTALL VENT BAFFLE(S) AT EXISTING ROOF VENT(S) IN ATTIC, REF. 4/A22 FOR DETAIL. ACCESS TO SITE AND PARKING 1. THE CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK OR BLOCK ACCESS TO HOMEOWNER DRIVEWAY. 1 _J REVIEWED F R CODE COMPLIANCE APPROVED MAY102U11 CityotTukwila BUILDING DIVISION A. SOUTH ELEVATION B. WEST ELEVATION C. NORTH ELEVATION D. EAST ELEVATION LEGEND u p ACOUSTICAL WINDOW NOT USED EXTERIOR STORM DOOR DIMENSIONS WILL VARY. SEE DOOR SCHEDULE ON ARCH. 42.0 SEE WINDOW SCHEDULE FOR WINDOW TYPES FLOOR / CEILING GRILL EXISTING KITCHEN EXHAUST ELECTRICAL PANEL FRESH AIR INTAKE GRILLE. REF. MECH. FOR UNIT. VENT BAFFLE 6 NOT USED NOT USED ATTIC INSULATION RECEIVED APR 2 9 2011 TCENTER INSTALL BATTERY OPERATED SMOKE DETECTORS KITCHEN EXHAUST BAFFLE NOT USED S.M.STEMPER ARCHITE CTS A Professional Limned Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 621 -2777 • FAX (206) 024 -2073 0810.03.1731 2/24/11 NTERNATIONAL AIRPORT KING COUNTY EDY IMPROVEMENTS w w 0 z U AIP NUMBER 5 -53- 0058 -043 z 0 DATE ISSUED 2/24/11 BID PACKAGE S -23 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH FLOOR PLANS (fit NOTES A1.0 0810.03.1731 WINDOW TYPES SLIDER 2'1" MAIN. 2 SLIDER/ FIXED/ SLIDER WINDOW SCHEDULE WIND. NO ROOM LOCATION WIND. TYPE SIZE W x H TRIM FINISH INT./ EXT. REMARKS EGRESS DETAIL SET A BEDROOM 1 2 S' -0" x 3' -0" PANT/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) Wt. 41" Y 1 /A2.0 5 BEDROOM 2 1 6' -0" x 2' -10" PAINT/PANT CUT SILL TO 40" AFF FOR EGRESS (E) HT. 47 Y 1 /A2o C BEDROOM 2 I 3' -10" x 2' -I0" PANT/PANT 1 /A2.0 D BEDROOM 3 I 3' -10" x 2' -I0" PANT/PANT I/A2.0 E BEDROOM 3 I 5' -10" x 2' -10" PANT/PAINT CUT SILL TO 40" AFF FOR EGRESS (E) HT. 4V Y 1/42.0 F KITCHEN 1 2' -II" x 2' -10" PANT/PANT I /42.0 G DINING ROOM 2 S' -0" x4' -10" PANT/PANT I:1:1 PROPORTION, REMOVE / REINSTALL (E) SHUTTERS 1/42.0 H LIVING ROOM 2 S' -0" x4' -10" PANT/PANT I:I:I PROPORTION, REMOVE / REINSTALL (E) SHUTTERS 1/42.0 I LIVING ROOM 2 S' -0" x4' -10" PANT/PANT 1:1:1 PROPORTION 1/42.0 (E) • EXISTING (E) WD. SIDING CAREFULLY LIFT (E) WALL UNDERLAYMENT AND INSTALL TOP EDGE OF SELF- ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) WALL UNDERLAYMENT OVER TOP OF SELF - ADHERING MEMBRANE. TYP AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF WINDOW ASSEMBLY 4 FLASHING. REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV 51-IEET METAL FLASHING UNDER SELF - ADHERING MEMBRANE. COLOR TO BE SELECTED IN THE FIELD TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMNED BACKER ROD 4 SEALANT (E) GLOB (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING SELF ADHERING MEMBRANE WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM ACOUSTICAL WINDOW ASSEMBLY CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WD. SIDING (E) WALL UNDERLAYMENT (E) EXTERIOR SHEATHING BACKER ROD 4 SEALANT ACOUSTICAL WINDOW ASSEMBLY ACOUSTICAL WINDOW ASSEMBLY BACKER ROD 4 SEALANT WINDOW NAILING FN WINDOW HEAD WD. JAMS LINING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WINDOW JAMB TRIM- MATCH (E) TRIM. PRIME ALL SIDES AND PAINT TO MATCH (E) TRIM. COLOR TO BE FIELD DETERMINED CAREFULLY REMOVE (E) WOOD SIDING FOR INSTALLATION OF WNDOW ASSEMBLY AND TRIM. REPLACE W/ NEW SIDING AS REQ'D TO MAINTAIN COURSING 4 PAINT TO MATCI-1 (E) SIDING (E) EXTERIOR SHEATHING (E) WD SIDING IOTI II 1 . 7 (E) GU. WOOD TRIM TO MATCH (E), PAINT/STAIN TO MATCH (E) TRIM IUD JAMB LNING SEALANT SHIM AS NECESSARY FILL GAP W/ BATT INSULATION 3/8" wgri"N FFA WINDOW SILL 3 BACKER ROD 4 SEALANT 3/4" WD. SILL - STAIN TO MATCH (E) WOOD TRIM TO MATCH (E), PANT /STAN TO MATCH (E) TRIM SELF- ADHERING MEMBRANE (E) GLUE WOOD SIDING - WINDOW DETAIL SET 3 "= 1' -0" 'PH TYPICAL WINDOW SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED N SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING PER CODE. 2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS. CODE FOR E COMPLIANCE t APPROVED MAY 10 2011 City of Tukwila BUILDING nIVI,CIfiM RECEIVED APR 29 2011 pERMITCENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2073 2/24/11 0810.03.1731 0 0 J z 0 z w z 0 U z MPROVEMENTS >- 0 C/) w w w 0 LI AIP NUMBER 5 -53 -0058 -043 DATE 2/24/11 ISSUED BID PACKAGE S -23 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA, LB &JH WINDOW TYPES, SCHEDULE & DETAILS A2.0 0810.03.1731 DOOR TYPES r 0 FLUSH SCW 3 LITES, 3 PANELS W/ SAFETY GLAZING W/ OBSERVATION PORT B c FLUSH SCW EXTERIOR HALF -LITE W/ SINGLE LEAF STORM 2 PANELS W/ SAFETY GLAZING W/ SAFETY GLAZING DOOR SCHEDULE DOOR NO ROOM LOCATION DOOR TYPE SIZE Wx H FINISH INT./ EXT. HARDWARE SET 1 FINISH KNOB / LEVER SET LOCK SET DETAIL SET 1 LIVING A 3' -0" x 6' -8" STAIN /STAIN 14W -1 / 626 DK -2 LOCK -1 1/A2.1 2 KITCHEN B 2' -8" x 6' -1" STAIN /STAIN HW -I / 626 DK -2 LOCK -1 1 /A2J 3 LIVING C 3' -0" x 6' -8" 1 /A2J 4 KITCHEN C 2' -8" x 6' -1" 1/A2.1 EXISTING SOFFIT AND FRAME WOOD TRIM CONTINUOUS SEALANT BEHIND Z BAR FRAME 2" MIN. 7 / / / / /fi'/ / / /// /r STORM DOOR FER SCHEDULE /// /i //fI DOOR HEAD CAREFULLY CUT BACK (E) WD. SIDING TO ALLOW FOR REATTACHMENT TO RO. FRAMING. LIFT (E) WALL UNDERLAYMENT AND INSTALL SELF ADHERING MEMBRANE WINDOW NAILING FLANGE AGAINST SHEATHING. INSTALL SECOND LAYER OF SELF ADHERING MEMBRANE OVER NAILING FLANGE AND LAP UNDER (E) WALL UNDERLAYMENT. CAULK, TOOL FLUSH, AND PAINT FASTENER HEADS AND ANY CRACKS WHICH DEVELOP IN SIDING FROM INSTALLATION OF FLASHING (E) WOOD SIDING CONTINUOUS SEALANT BEHIND Z BAR FRAME STORM DOOR PER SCHEDULE KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR JAMB JAMB BEYOND i MIN. WOOD TRIM TO MATCH (E), PANT/STAIN TO MATCW (E) TRIM SHIM AS NECESSARY FILL GAP W/ BATT INSULATION WOOD FRAME KERF AS REQUIRED FOR WEATHER STRIPPING INSTALLATION CONTINUOUS WEATHER- STRIPPING DOOR PER SCHEDULE WOOD DOOR PER SCHEDULE DOOR SHOE 2" MN. AUTOMATIC DOOR SWEEP OAK AND METAL THRESHOLD ADJUSTABLE SWEEP EXISTING FLOOR STRUCTURE (E) EXTERIOR SHEATHING EXISTING FRAMING WOOD TRIM TO MATCH (E), PAINT /STAIN TO MATCH (E) TRIM 514IM AS NECESSARY FILL GAP W/ BATT INSULATION DOOR SILL WOOD SIDING - DOOR DETAIL SET DOOR PER SCHEDULE 3 " =1' -0" TYPICAL DOOR SCHEDULE NOTES I. NOTE: WHERE SAFETY GLAZING I5 INDICATED, BUT NOT SCHEDULED IN SECTION 08800 ALL UNLAMINATED GLAZING PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION AS SAFETY RATED GLAZING FER CODE. 2. SLIDING GLASS DOORS SHALL, MATCH THE OPERATION OF THE EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER. 3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS. REVIEWED F R CODE COMPLIANCE APPROVED MAY 10 2011 City of Tukwila BUILDING DIVISI(1N os RECEIVED APR 29 2011 PERMIT CENTER S.M.STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 624 -2973 .mi n : 0810.03.1731 2/24/11 0 0 J z 0 z w H z 0 U Ca z MPROVEMENTS W W W 0 Z W cn ce AIP NUMBER 5 -53- 0058 -043 z 0 co DATE 2124111 ISSUED BID PACKAGE S -23 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH DOOR TYPES, SCHEDULE & DETAILS A2.1 0810.03.1731 CAREFULLY LIFT (E) WALL UNPERLAYMENT AND INSTALL TOP EDGE OF SELF ADHERING MEMBRANE AGAINST SHEATHING. LAP (E) UJALL UNPERLAYMENT OVER TOP OF SELF- ADHERING MEMBRANE. TYP. AT HEAD AND JAMB REMOVE (E) WOOD SIDING AS REQ'D FOR INSTALLATION OF VENT FIXTURE 4 FLASHING, REPLACE W/ NEW SIDING 4 PAINT TO MATCH (E) SIDING PRE- PRIMED, GALV. SHEET METAL FLASHING W/ F.F. END CAPS UNDER SELF - ADHERING MEMBRANE. EXTEND FLASHING 4" UP UJALL. HELD PAINT FLASHING - COLOR TO BE SELECTED IN THE FIELD EXTERIOR VENTILATION FIXTURE. REF. MECH.- PAINT INTERIOR W/ ACOUSTICAL DAMPING COMPOUND. 5Et IN MASTIC AT EXTERIOR TRIM. (E) WALL UNDERLAYMENT SELF- ADHERING MEMBRANE (E) EXTERIOR 51EATI -11% REMOVE / REPLACE SIDING AS REQUIRED. 2X2 CONTINUOUS PRESSURE TREATED BLOCKING, 4 SIDES AIR INTAKE DETAIL AT EXTERIOR 3 "= 1' -0" _z EXISTING ROOF VENT EXISTING ROOF STRUCTURE u CROSS SECTION EXISTING VENT COVER EXISTING ROOF STRUCTURE NEW 2"X SPACER AS REQUIRED TO PROVIDE 6" CLEAR AIR SPACE NEW 2 "X SPACER LATERAL SECTION 6" MIN. TYPICAL TOP 4 BOTTOM NEW 1" INSULATION BOARD GLUED TO NEW 3/4" EXTERIOR GRADE PLYWOOD. ROOF VENT BAFFLE DETAIL 1-1/2" = 1' - 0" EXISTING ROOF (E) ROOF FRAMING (E) SOFFIT VENTS (E) 2X10 *16" O.C. (E) GLUE/ INSULATION DAM DETAIL 3 " =1' -0" (E) ATTIC INSULATION INSULATION DAM (E) WALL FRAMING ANCHOR CEILING NAILER TO (E) RESILIENT CHANNEL ONLY. DO NOT ANCHOR TO JOIST WHERE WIDTH OF SOFFIT EXCEEDS 16 ", INSTALL 2X4 STUDS a 16" O.C. J -METAL EDGE AND CAULK JOINT DUCT SOFFIT DETAIL 1- 1/2 " =1' -0" DEMOLISH (E) GUS / PREMANUFACURED ROOF BAFFLE ( AN- MODEL EXIST DUCTWORK NAILS WITH ROOF CEMMT SEAL SHINGLES TO ROOF GAP ON TOP AND SIPES NOTE: 1 PRE MANUFACTURED ROOF BAFFLE. INSTALL PER MANUFACTURE'S INSTRUCTIONS. NOTCH TOP PLATE AND TRIM STUDS OF PARTITION AS REQ'D TO ACCOMMODATE PASSAGE OF MECH. COMPONENTS. WALL PENETRATIONS SHALL BE CUT FALL SIZE OF SOFFIT AREA, TYPICAL 2x BLOCKING BETIEEN STUDS WHICH REQUIRE TRIMMING 2x2 CONT. NAILER 5/5" GWB- PAINT TO MATCH (E) TEXTURE 4 COLOR OF CEILING. ENCLOSE DUCTS TIGHTLY, OR TERMINATE EDGE W/ ADJ. ARCHITECTURAL FEATURES PER PLAN. COORDINATE SOFFIT DIMENSIONS WITH MECHANICAL (E) WP FRAME WALL ASSEMBLY KITCHEN EXHAUST BAFFLE 1 1/2" = 1' - 0" CODE FOR E COMPLIANCE , APPROVED MAY 10 2011 City of Tukwila BUILDING fRncir RECEIVED APR 292011 P RMITCENTER S.M.STEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624 -2777 • FAX (206) 824 -2973 !r 2/24/11 0810.03.1731 0 O- W -J Cl Q Z w O � 1 w Z w L11 p Z gLI- Z U O Q 0 J Z Q MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE ISSUED 2/24/11 BID PACKAGE S -23 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH MISC. DETAILS A2.2 0810.03.1731 LIFT (E) BLDG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD BUTTERFLY CORNERS, TYP. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE MD OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. 12° LAP SILL MEMBRANE FLASHING I -1/2" OVER (E) BLDG. PAPER At SILL. EXTEND 1 BEYOND P.A. At EA. END OF SILL. (E) BLDG. PAPER AT SILL (E) SHEATHING CUT SILL FLASI -I NG 4 FOLD THROUGH RO. AS SHOWN. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING I }" MN '-`14/2" TYP. MEMBRANE FLASHING AT SILL 5.. BUTTERFLY CORNER FLASHING SCALE: NTS LIFT (E) BLPG. PAPER AWAY LOOSELY FROM (E) SHEATHING AT JAMBS AND HEAD. (E) SIDING NOT 91-1O1UN FOR CLARITY. NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. WINDOW NAIL FLANGE: EMBED WINDOW HEAD AND JAMS NAIL FLANGE IN SEALANT. ENSURE COMPLETE SEAL BETWEEN FLASHING AND WINDOW FLANGES. SEALANT SHOULD FLOW OUT BEYOND EDGE OF WINDOW FLANGE AND U FILL SHO LD LL NAIL HOLES REMOVE EXCESS MATERIAL. DO NOT SEAL FLANGE AT WINDOW SILL (E) BLDG. PAPER AT SILL. ELEVATION VIEW NOTE: INSTALL WINDOW PER MFG'RS SPECIFICATIONS. NOTIFY TECHNICAL REPRESENTATIVE OF DISCREPANCIES WINDOW MEMBRANE INSTALLATION MEMBRANE FLASHING PREVIOUSLY APPLIED TO WINDOW OPENINGS. BEND ANCHORAGE NAILS DOWN OVER NAIL FLANGE, HEAD ONLY. (E) SHEATHING SCALE: NTS REMOVED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. LAY (E) BLDG PAPER BACK DOWN OVER FLANGE FLASHING AT JAMBS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'D (E) SIDING NOT BHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. LUHERE REQUIRED, TRIM (E) BLDG PAPER AT I4EAD TO PRE ARE FOR INSTALLATION OF HEAD FLASHING AND WINDOW TRIM (FOLLOWING STEPS). 8 HEAD FLASHING PREPARATION } SCALE: NTS (E) BLDG. PAPER NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS BEEN INSTALLED. CUT JAMB FLASHING 4 FOLD AROUND WINDOW �1. OPENING AS SW WINDOW EXTEND 1 -1/2" BEYOND �` ` EDGE OF OPENING AT ''.;4i , > HEAD, JAMBS, AND SILL. ADHERE MEMBRANE FLASHING TO OUTSIDE FACE OF WALL SHEATHING MEMBRANE FLASHING AT JAMB SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 14A5 BEEN INSTALLED. 3'TYP. f-f INSTALL SILL FLANGE FLASHING OVER WINDOW NAI L FLANGE AND FLASHING. INSTALL 514T. METAL I4EAD FLASHING UNDER (E) BLDG PAPER. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'O (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR NSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. ALLOW 1/8" ¢LEARANCE BETWEEN FLASHING AND 80T. EDGE ��bFFF (E) SIDING. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -I/2" BEYOND RO. At HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) ('\ MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. 3" Tr'. - INSTALL JAM FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. 6 �� MEMBRANE FLASHING AT JAMB SCALE: NTS GENERAL NOTES: I: MEMBRANE FLASHING 15 SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND l" REFER TO MEMBRANE INSTALLATION AFTER WINDOW WAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: PETALS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. REV tivro CODE COMPLIANCE APPROVED ED MAY102011 City of Tukwila BUILDING DIVISION NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL UV. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. • 0 0 WINDOW FLASHING INSTALLATION SCALE: NTS RECEIVED APR 2 9 2011 PERMITCENTER S.M.STEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2973 2/2.4/11 0810.03.1731 0 a -J Z 0 z w z 0 U 0 Z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE S -23 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1731 v \ . :� � .'ti 1ia>:u�:J'.•i:...,:w:i4 }'•,'•.h1:ti�v\ a4:. .1.. ++;;1+w:;M e,;::•sae�ti mcv:•. 4•:.v :;:4�. < ....................... ......................: $iti•:i :: ::::};•;:;:;•:v:i <::: ti:::•j;: >::::$Q: +�::+:•::v:• %:492.• };: Z.4 }A. vii, ,•'.F:::: INSTALL SILL FLANGE FLASHING OVER WINDOW NAI L FLANGE AND FLASHING. INSTALL 514T. METAL I4EAD FLASHING UNDER (E) BLDG PAPER. MEMBRANE FLASHING AT SILL SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS REQ'O (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR NSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. ALLOW 1/8" ¢LEARANCE BETWEEN FLASHING AND 80T. EDGE ��bFFF (E) SIDING. TRIMMED EDGE OF (E) SIDING, SHOWN DIAGRAMATICALLY. (E) SIDING NOT SHOWN FOR CLARITY. HEAD FLASHING INSTALLATION SCALE: NTS (E) BLDG. PAPER CUT HEAD FLASHING 4 FOLD AROUND WINDOW OPENING AS SHOWN. EXTEND I -I/2" BEYOND RO. At HEAD AND JAMBS. ADHERE PENETRATION FLASHING TO OUTSIDE FACE OF WALL SHEATHING (TYP. EACH SIDE OF WALL) ('\ MEMBRANE FLASHING AT HEAD SCALE: NTS NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING 1445 BEEN INSTALLED. 3" Tr'. - INSTALL JAM FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. 6 �� MEMBRANE FLASHING AT JAMB SCALE: NTS GENERAL NOTES: I: MEMBRANE FLASHING 15 SPECIFIED IN 01211 AS "SELF ADHEARING MEMBRANE FLASHING" TYPICALLY REFERED TO AS "PEEL AND STICK" 2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE INSTALLATION PRIOR TO WINDOW INSTALLATION 3: DETAILS "5, 6, AND l" REFER TO MEMBRANE INSTALLATION AFTER WINDOW WAS BEEN SET IN PLACE, SHIMMED, AND ANCHORED. 4: PETALS "8 AND 9" REFER TO SHEET METAL HEAD FLASHING. 5: DETAILS 10 REFER TO WOOD TRIM AND CAULK JOINTS. REV tivro CODE COMPLIANCE APPROVED ED MAY102011 City of Tukwila BUILDING DIVISION NOTE: REMOVE (E) SIDING BACK FROM (E) RO. AS REQ'D (E) SIDING NOT SHOWN FOR CLARITY. REPLACE AND OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING HAS SEEN INSTALLED. INSTALL HEAD FLANGE FLASHING OVER WINDOW NAILING FLANGE AND FLASHING. (E) SIDING (E) BLDG. PAPER BENEATH SIDING INSTALL UV. TRIM. BUTT TIGHT TO TRIMMED EDGE OF (E) SIDING. APPLY SEALANT BEAD TO JOINT BETWEEN WINDOW TRIM AND SIDING. LEAVE i" GAP BETWEEN WINDOW TRIM AND WINDOW FRAME. INSTALL CONT. BEAD OF SEALANT AND BACKER ROD IN GAP. • 0 0 WINDOW FLASHING INSTALLATION SCALE: NTS RECEIVED APR 2 9 2011 PERMITCENTER S.M.STEMPER ARCHITE CTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (208) 824 -2777 • FAX (208) 824 -2973 2/2.4/11 0810.03.1731 0 a -J Z 0 z w z 0 U 0 Z MPROVEMENTS AIP NUMBER 5 -53- 0058 -043 DATE 2/24/11 ISSUED BID PACKAGE S -23 100% CD PROJECT ARCHITECT JO PROJECT MANAGER ML &TF DRAWN AA,LB &JH WINDOW FLASHING DETAILS A2.3 0810.03.1731 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR OR XX 0 X/Y DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1,0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MAIN FLOOR MECHANICAL PLAN AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 5. AIRTIGHT. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 6. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 8. THERMOSTATS 4' -O" AFF. UNLESS NOTED OTHERWISE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, 9. ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 1O' -0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3' -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. 7. 10. 11. 12. SYMBOL ABBR SG -X XXX + f + DN UP VD RA /EA RG -�- SA SA 40- 0-F- RA /EA SD EA DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH OR THERMOSTAT EQUIP ID _ EQUIPMENT LOCATION —NG— • 0 Db MOD NG MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE /DUCT ELBOW DOWN PIPE /DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION REMARKS DESCRIPTION VOLTS PH 248 G08 "WG 10"0 EXTERIOR 15 16 15 16 N/A 15 16 N/A - MOTOR OPERATED DAMPER 24 1 X X X 1,2 - THERMOSTAT 24 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE LOCATION REMARKS WC -1 EXTERIOR 135 248 G08 "WG 10"0 EXTERIOR 1,2 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.1731 1168 3 135 CFM 135 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51 -51 -1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION 1 MIN VALUE (NOTES ON ROOF OR ON EXTERIOR OF BUILDING R -8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR /CEILING R -8 1,2,3 WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS R -8 1,3 IN CEMENT SLAB OR IN GROUND R -5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR /CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 01011 AND 02080 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 01011 AND 02080 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. *PI 1 (1 THERMOSTAT /SWITCH HOURS OF OPERATION SET THERMOSTAT /SWITCH TO OPERATE 1 OF EVERY 3 HOURS. MECHANICAL VENTILATION CALCULATION PER WAC 51- 52- 0403.8 (GROUP R OCCUPANCIES) QF = QR / (&EGR X F) QR = (FROM TABLE 403.8.1) 4.5_ &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION l[ QF = 45 / (1 X 1 /3) = 135 CFM RECEIVED APR 29 2011 PERMITCEENTER ell 4) S.M. STEMPER ARCHITECTS A Prefamsfaxial limited. Llab11itp Company 4000 DELRIDGE WAY SW sum 200 ^ RATTLE, SPA 98100 000 6.24-2777 • FAIC 000) 924- 2073 THE GREENBUSCH GROUP, INC 1000111 L. wa o 511111°E1111213 � 30W1 l 1 FI9L 1 1oE 0V d. N119 (200) 378 -0599 (209) 379 -0841 FAX CO C DING COUNTY INTERNATIONAL AIRPORT w ce w O z LL 0 cc w w AIP NUMBER 5-53-0058-043 DATE SEATTLE WASHINGTON 2124111 ISSUED E3ft) PACKAGE S -23 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, MM & JA LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX EXPIRES: 9/081 Q4t! D IN ING ROOM KITC1 N CEILING 20' x 26s° EXIST. ATTIC ACCESS PANEL (E)SG D ROM 3 SOFFIT BY OTHERS BERG CLOG E a ITT LIVING ROOM CL.O5ET E DIRooM 1 BEDROOM ROOM 2 Maa MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1' -0" FURNACE FLOOR VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN MOD, INTERLOCK TO FURNACE POC (E)SUPPLY OUTSIDE AIR TO FURNACE ELEVATION SCALE: NONE GM L ! NORTH SHEETMETAL TRANSITION TO GRILLE NECK SIZE DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY DUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 2 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SMC 401.5.1. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51 -52- 0403.8.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY - CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51 -52- 0403.8.2 -5.8. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51 -52 403.8.7.2 CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE /RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED. DUCT PER PLAN CAULK FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL WALL CAP PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. COORDINATE WITH ARCHITECTURAL TECHNICAL DOCUMENTS, REFERENCE 1/A2.2 FOR DETAIL. WALL CAP CONNECTION DETAIL SCALE: NONE PH los RECEIVED APR 2 9 2011 PERMITCENTER S.M. STEMPER ARCHITECTS A. PINgibankm&I u», tee 1elabi tty Coi pa py 4.000 DELEIDGE WAY SW SUITE 200 , RA's, WA 96100 (rasa) 624 -2777 • FAX (St) 624-21973 THE GREENBUSCH GROUP, INC Acaosnc�I. AWED SIRS a E109411991'A E11991®rxi 1900 9F81 SIRFET 9UIIE 401 SE171,B r1 90119 (200) 372 -0309 (200) 378 -0941 FAX 0810.03.1731 NTERNATIONAL AIRPORT KING COUNTY ED'S IMPROVEMENTS FT NOISE RE RESIDENTIAL A1RC AIP NUMBER 5-53-0058-043 SEATTLE WASHINGTON DATE 2124111 ISSUED BID PACKAGE S -23 100% CD PROJECT ENGINEER CA PROJECT MANAGER CA DRAWN CA, MM & JA MAIN FLOOR MECHANICAL PLAN AND DETAILS M2.0 0810.03.1 731 ELECTRICAL - PROJECT NOTES 1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8: 00 AM TO 5: 00 PM, ALL ELECTRICAL WORK FOR EACH DAY MUST BE COMPLETED IN THAT TIME PERIOD. 2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED AFTER WORK IS COMPLETED. 3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER 5:00 PM. 4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT LINES, PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH —IN. PAINT TO MATCH SURROUNDING CONDITIONS. 5. COORDINATE REQUIREMENTS FOR ALL WORK WITH ARCHITECT PLANS AND SPECS REGARDING WORK ON HISTORIC HOMES. SPECIAL METHODS AND COORDINATION SHALL BE GIVEN TO ALL WORK WITHING OR ON THIS RESIDENCE TO MAINTAIN HISTORIC VALUE. VERIFY REQUIREMENTS WITH ARCHITECT. ALL NEW WORK SHALL BE CONCEALED. ELECTRICAL PLAN NOTES 0 PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE. 0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS. 0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WRING SPECIFICATIONS FOR SWITCH. 0 PROVIDE INTERCONNECTED 120V SMOKE DETECTOR WITH BATTERY BACK. SEE SPECIFICATION SECTION 16100. PROVIDE CEILING TYPE BACK BOX. PROVIDE NEW CIRCUIT AS INDICATED FOR DETECTORS IN ACCESSIBLE ATTIC. CONNECT EACH DETECTOR TO 12OVac AND PROVIDE COMMUNICATION WIRE BETWEEN DETECTORS AS INDICATED IN DETAIL. SEE GENERAL NOTES FOR CEILING PENETRATION REQUIREMENTS. 0 HOME RUN CIRCUIT TO PANEL AND MAKE ALL CONNECTIONS COMPLETE. SEE GENERAL REQUIREMENTS FOR ANY CEILING OR WALL PENETRATION WORK. 0 PROVIDE NEW 15/1 BREAKER IN PANEL AND 2 #14 &G TYPE NMB CONDUCTOR FOR SMOKE DETECTORS TO MATCH EXISTING. SEE PANEL SCHEDULE. SEE GENERAL REQUIREMENTS FOR ANY WALL PENETRATION WORK. ELECTRICAL LEGEND S`r IBOL DESCRIPTION SYMBOL DESCRIPTION 120 /240 VOLT, 1 PHASE, 3 WIRE. SKR r 0 - -------------------------------------- E G -m J LJGHIING OR POWER PANEL BRANCH CIRCUIT WIRING AND CONDUIT AS REQUIRED FOR CKTS DEVICES AND EQUIP INDICATED ON PLANS. (WIRING AND CONDUIT SIZE MAY NOT APPEAR ON PLANS). PROVIDE CONDUCTORS AND CONDUIT PER NEC CODE. #12 AWG, 1/2 °C. MIN. EMT OR RIGID STEEL 1 INDICATES EQUIP GND. 1 INDICATES ISOLATED GROUND. MAST, WEATHERHEAD BRANCH CIRCUIT HOME RUN - ❑' - -- - - - EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES FOR SPECIFIC REQUIREMENTS. DAMPER CONNECTION NON —FUSED DISCONNECT SWITCH TOGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS FIRE ALARM SMOKE DETECTOR 120V OPERATED - -- FIRE ALARM SMOKE DETECTOR /CO SENSOR 120V OPERATED - - - - -- ELECTRICAL METER — — — AERIAL SERVICE CONDUCTORS, COORDINATE WITH UTILITY. CKT LOAD DESCRIPTION TIMER OPERATED SWITCH KVA NP jT THERMOSTAT PANEL MP LOCATION: SERVING: 10,000 120 /240 VOLT, 1 PHASE, 3 WIRE. SKR RESIDENCE AC, 125 AMP with MAIN CKT LOAD DESCRIPTION TYPE KVA NP PHASE NP KVA TYPE LOAD DESCRIPTION CKT 1 EXIST CKT 40/2 A 60/2 2 3 B 4 5 EXIST CKT 30/2 A 30/2 6 7 9 11 13 15 EXIST CKT EXIST CKT EXIST CKT EXIST CKT 20/1 20/1 20 /1 1511 A A B B B 1511 15/1 1511 1611 0.01 D SMOKE DETECTORS 8 10 12 14 16 LOAD TYPE L R M H WI-I D A -4 K LM TOTAL LOADS CONN. LOAD 0,01 0.01 KVA 004 AMP COMPUTED LOAD 001 0.01 KVA 0.04 AMP ❑ ISOLATED GROUND BUS ❑ FEED THRU LUGS ❑ MAIN BKR SHUNT TRIP ❑ RAINTIGHT NEMA -3R ENCLOSURE ❑ DOUBLE LUGS ❑ SERVICE ENTRANCE LABEL PANEL SKIRTS INTEGRAL SURFACE FLUSH • • ❑ TVSS 0 REMARKS: 15/1 L —0 0 BLACK N WHITE BK BLACK WHITE RED BLACK WHITE SMOKE DETECTOR WIRING DIAGRAM NO SCALE MECHANICAL I ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 15 16 15 16 I N/A MOTOR OPERATED DAMPER 24 1 X X THERMOSTAT 24 1 X X REMARKS: 1 — VER FY QUANTITY FROM PLANS TYPICAL ALL) 2 — DISCONNECT SWITCH 15 16 N/A REMARKS X 1, X [OS 1K.I TCAFN EATH 1 TO RJRNACE DOVER CLOSET 2v" x 26" EX Sit. ATTIC ACCES PAS EL 7.ED>c OOh1 :3 II !- ila'�.r; 0 n E > ROC RECEIVED APR 2 9 2011 PERMIT CENTER NORitlp Z� SSMISTEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 0 /3106 (206) 624 -2777 • FAX (206) 624 -2973 ENGINEERS. INC NW SIM MO UM OMIT IBM 1110=11. 0111111141141 ,IYPIWIE PR MO UM Plitt 41111 SOS 0810.03.1731 i- ce O 0 >i' J Z ° P- 0 w z Q � z Q w 0 - z 0 Cn rt O _ 0 < (' J Z z w v ) LfL MPROVEMENTS AIP NUMBER 5- 53- 0058 -043 DATE 02/24/11 ISSUED BID PACKAGE M -24 100% CD PROJECT ENGINEER CHL PROJECT MANAGER BCR DRAWN JAB FLOOR PLANS NOTES E1.0 0810.03.1731