Loading...
HomeMy WebLinkAboutPermit D11-146 - WESTFIELD SOUTHCENTER MALL - MARK'S HALLMARK - INTERIOR DEMOLITIONMARK'S HALLMARK 2867 SOUTHCENTER MALL D11 -146 City otkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 9202470010 Address: 2867 SOUTHCENTER MALL TUKW Suite No: Project Name: MARK'S HALLMARK Permit Number: Issue Date: Permit Expires On: D11 -146 06/29/2011 12/26/2011 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: RANDY RIGGS Address: PO BOX 1036 , ENUMCLAW WA 98022 Contractor: Name: TENANT CONTRACTORS INC. Address: P.O. BOX 1036 , ENUMCLAW, WA 98022 Contractor License No: TENANCI132DA Phone: 253 -569 -7560 Phone: 360 825 -3376 Expiration Date: 05/12/2012 DESCRIPTION OF WORK: DEMO EXISTING FITTING ROOMS, PATCH & REPAIR, PAINT & CARPET. EXISTING STORAGE RACKS REMAIN. Value of Construction: $4,500.00 Fees Collected: $306.95 Type of Fire Protection: SPRINKLERS /AFA International Building Code Edition: 2009 Type of Construction: II-B Occupancy per IBC: 0019 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11 -146 Printed: 06 -29 -2011 • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Size (Inches): 0 Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: (' del' 1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the p- r ance of wo31 j I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: 4 d,p4 -r Ayr Date: fi 2 `(:/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). doc: IBC -7/10 D11-146 Printed: 06 -29 -2011 7: All electrical work shall be inspected an IF roved under a separate permit issued by tl ty of Tukwila Building Department (206- 431 - 3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ** *FIRE DEPARTMENT CONDTITONS * ** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (EEC 906.7 and IFC 906.9) 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 16: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 17: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 18: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 19: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 20: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 21: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I ", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 22: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on -site generator. (IFC 1006.1, 1006.2, 1006.3) doc: IBC -7/10 D11-146 Printed: 06 -29 -2011 23: Emergency lighting facilities shall be a ed to provide initial illumination that is at 1 average of 1 foot -candle (11 lux) and a minimum at any point of 0.1 foot - candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot - candle (6 lux) average and a minimum at any point of 0.06 foot -candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to- minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 24: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 25: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 26: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 27: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 28: Maintain fire alarm system audible /visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible /visual notification devices. (City Ordinance #2051) 29: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this project. 31: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 33: Post address on storefront per approved Westfield standards. 34: This review limited to speculative tenant space only - special fire permits may be necessary depending on detailed description of intended use. 35: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 36: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 37: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11-146 Printed: 06 -29 -2011 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 httn://www.ci.tukwila.wa.us Building Permit No. Mechanical Permit No. g(0 Plumbing /Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: ,2 B c--1 So)A C0-04-tr `! Tenant Name: al rf S 1111 ftrk, Property Owners Name: King Co Assessor's Tax No.: 5 14)...4-7 7 — "VOt U Suite Number: - 7- 3 (7 Floor: 2- New Tenant: L . Yes ❑ ..No q-22iLI Mailing Address: l-13O se lJ 4% e r ' r'J r City State Zip CONTACT PERSON - who do we contact when your permit is ready o be issued Name: q Y1 d L1 Kt - Mailing Address: P 0 7-3.0-4. 10 6 C- r, l4 ,-v1 c t.,% E -Mail Address: 1C / L'- s k YNerl;l Day Telephone: . C_. t 5 5-6 7 W/- q T vz 7- 6G City State Fax Number:`, 60 Z• 5 7 Zip GENERAL CONTRACTOR INFORMATION (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: 7 /?A, Cvi/'/r.9e_10 l ..7 /I r= Mailing Address: ? v Z &. /o",..7., 6 e/'L /,??C l4 i✓) 4.44' 7 !J e2"'-2' Contact Person: E -Mail Address: ,% 'i--7- �° S�c ,V�ti % �S'' : Contractor Registration Number: re-'="4/41 ,'U cy- 4;2- OA City State Day Telephone: 2 S3 56? 7,56. Fax Number: 24 -' 32-5 ?A-1 Expiration Date: S - -/S '-P/ 2- Zip ARCHITECT OF RECORD - All plans must be stamped by Architect of Record Company Name: eh cis 1 /rte. a /( Mailing Address: 2-7 2-a- `(?Z - v o44/ t1i4 g tT 2 Contact Person: r" 4 // S /' City Day Telephone: 3 State Zip 6%, 8z$ E -Mail Address: Fax Number: ENGINEER OF RECORD -Alt plans must be stamped by Engineer of Record Company Name: 21 /4 Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip n: \Applications \Forms - Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 1 of 6 BUILDING PERMIT INFORMATION - 206 -431 -3670 vl Valuation of Project (contractor's bid price): $ ' / r 0 LJ Existing Building Valuation: $ Scope of Work (please provide detailed informat)on): ,j c /►r) 0 «X t `, /1) r�` i / /2 f'oo ,4i_ (96 '��= r d- Air • P0/111- c- De . 1 ,? e (ArkS 1 G J� J/ / .s ,JY/ tfC/�'llirlt Will there be new rack storage? ❑ Yes 15. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers si Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes M. No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7.2010 bh Page 2 of 6 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC '- Type of Occupancy per I13C Pt Floor ,' ?),--11 a ,. /✓) 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION /HAZARDOUS MATERIALS: Sprinklers si Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes M. No If `yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System - For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7.2010 bh Page 2 of 6 PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE j.�R AUTHORI7,E� AGENT: Signature: % 164 Print Name: 6874.Y0 S- �� fiC <J uJ Mailing Address: O 8o- - Jo-3( IDate Application Accepted: 5r 41 Date:'. 2■ S l 507 ?✓ 4 ( i Day Telephone:✓ J ' Wry 93ozi City State Zip Date Application Expires: Staff Initials: H:\ApplicationsWorms- Applications On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: D11 -146 Address: 2867 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/25/2011 Applicant: MARKS HALLMARK Issue Date: Receipt No.: R11 -01071 Payment Amount: $306.95 Initials: WER Payment Date: 05/25/2011 01:07 PM User ID: 1655 Balance: $0.00 Payee: TENANT CONTRACTORS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5496 306.95 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $306.95 183.30 119.15 4.50 doc: Receiot -06 Printed: 05 -25 -2011 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 11-1 -1�, Project: / 1 M AR. K S 1 flu S 4 142 V Type of Inspection: e nnF(Z (,,FAlC1q L t ro Fr 14 J ? Address: -8(p7 (WT440Pn4'7F Q rr Date Called: ALi- Special Instructions: Date Wanted: 7- 2I —I1 atm. CM- Requester: Phone No: ,15:3 -"S lt,g -7566 WApproved per applicable codes. aCorrections required prior to approval. COMMENTS: ji CwlsRA04r`Y L:4k0^,5- r'-0,04V,k 'ok-A ✓ -r zPo r N-, i k �t(�,,..� (' i' 11-- ki s x Insp- r: n REIN PECTION FiE REQUIRED Prior to n, xt inspection, fee must be paid t 6300 Southcenter Blvd.. ite 100. Call to schedule reinspection. Date: 7-2I- ( J '• 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Lirie (206) 431-2451 INSPECTION RECORD • Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION fej P W. ect: . 41C. eair+ on,t _ v Bizt Type of Inspection: e (445, .5 DISO, NM Jai "Inc, WIC Addre s: S Pho Si Date Called: 0-742-b, Special Instructions: . e Code: 030 Date Wanted: a.m. Requesteu—, , Phone No: P13 e a -75o9 Approved per applicable codes. Corrections.required prior to approval. COMMENTS: -a- 1PiPtskieot — rit;tAteof __ rin4e d - rine, (to 4 - Ft ii-c4ed - etm diA 4 ibiSfa Nit n of dixv iti o vk Lia . Inspector: et:PS !Date: _ I 7/(3/1 _ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIREPEPARTMENT 444 Andover 'Park East, Tukwila, 11 aC. 98188 206- 575 -4407 Project:, ,�A �eq p /< ' Type of Ins ion: ittb C/4.-- k Address: Dg (o` Suite #: -- , S- C . MALL- ; Contact Person: 1 Special Instructions: f Phone No.: ICI Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: Sprinklers: ittb C/4.-- k -(- Ca a. lv,oK,n. c•Y� E�°�" i dk(,) J. Pre -Fire: 1 Occupancy Type: f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: inspector: ie,- bye., 52- Date: -210) ( t 1 i Hrs.: ( $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: 1 State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 .r; • 'Y z. • 1 s; • • • • • ; • June 15, 2011 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Randy Riggs PO Box 1036 Enumclaw, WA 98022 RE: Correction Letter #1 Development Permit Application Number D11 -146 Mark's Hallmark — 2867 Southcenter Mall Dear Mr. riggs, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning, and Public Works Departments have no comments. Building Department: Dave Larson at 206 431 -3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and /or other documentation. The City requires that four (4) sets of revised plans, specifications and /or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Jenn Perm e File No. D11 -146 er Marshall t Technician W:\Permit Center\Correction Letters\2011\D11 -146 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: June 6, 2011 Project Name: Marks Hallmark Permit #: D11 -146 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. There are two pages showing different light fixtures for the retail area, page RC and page A -3. Both state that these are existing ceilings. Please fill out a Wash. State Energy Code Lighting Budget Form. Please clarify on the plans which fixtures are existing and which fixtures will be new. I have enclosed the lighting budget with this review memo. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -146 DATE: 06 -17 -11 PROJECT NAME: MARK'S HALLMARK SITE ADDRESS: 2867 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENT ,11 ui ding Division Public Works ❑ Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete am, Incomplete 111 DUE DATE: 06-21-11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route 1$1 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 07-19 -11 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 *PE yT' ' • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -146 DATE: 05 -25 -11 PROJECT NAME: MARKS HALLMARK SITE ADDRESS: 2867 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPAR MEN S: 10`6"/I h ui ing 110IPv l�i ,Vi Public Works V M\ ire Prevention Structural - NOk pc.1 -gyp• timik Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 05-26-11 Not Applicable Comments: Permit Center Use Only. INCOMPLETE LETTER MAILED:. LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route N Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-23-11 Approved Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:J/VA Documents /routing slip.doc 2 -28 -02 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.citukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: V l '' (4 7 . I ` Plan Check/Permit Number: D11-146 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Mark's Hallmark Project Address: 2867 Southcenter Mall Contact Person: ailli Phone Number: 125'3 S" 69—.1510 Summary of Revision: re, 4 r 8# ee( 4-- -3 p g76 is- tt corilect- ce/A05 ' /in RECSVED $w+wke JUN 17 all PERM► t x.,� Sheet Number(s): "Cloud" or highlight all areas of revision including date of revis n Received at the City of Tukwila Permit Center by: 1 -- Entered in Permits Plus on (4 `C 'i-- 1 \applications\forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople itter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name TENANT CONTRACTORS INC UBI No. 601009709 Phone 3608253376 Status Active Address Po Box 1036 License No. TENANCI132DA Suite /Apt. License Type Construction Contractor City Enumclaw Effective Date 3/1/1987 State WA Expiration Date 5/15/2012 Zip 98022 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date RIGGS, TAMARA J Member 01/01/1980 Bond Amount RIGGS, RANDY SCOTT President 03/01/1987 9804518 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 9 Lexon Ins Co 9804518 03/01/2011 Until Cancelled $12,000.0002/10 /2011 8 COLONIAL AM CAS & SURETY OF MARYLAND LPM4067923 03/01/2005 Until Cancelled 03/01/2011 $12,000.00 02/11/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 18 Liberty Northwest Ins Corp BK052830437 05/19/2011 05/19/2012 $1,000,000.0004 /20/2011 17 LIBERTY NORTHWEST INS CORP BLW52830437 05/19/2010 05/19/2011 $1,000,000.0005 /06/2010 16 OHHIO CAS INS CO BLW052830437 05/19/2003 05/19/2010 $1,000,000.00 04/27/2009 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https: / /fortress.wa. gov /lni/bbip /Print.aspx 06/29/2011 FIXTURE LEGEND: HALLMARK FIXTURE OWNER SUPPLIED FIXTURE EXISTING / NON - CURRENT WALL LEGEND: NEW CONSTRUCTION EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED EJ) k 30, -0" 3O, -0" REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 3 2011 City of T Ila BUILDING ISION 65' 3" 16' 3" /--MAPLE TRM / MAPLE TRM / MAPLE TRM / FASCIA / MAPLE TRM / MAPLE TRM / MAPLE TRM--/--FASCIA / MAPLE TRM / MAPLE TRM / MAP E TRM / MAPLE TRM / FASCIA / MAPLE TRM / MAPLE TRM- -/ GREETING CARDS GIFT WRAPS TRIM GIFT WRAPS TRIM NOTE= INTENT OF THIS DRAWING SET IS TO SHOW THE RELATIONSHIP OF DESIGN ELEMENTS THAT ARE NECESSARY FOR USE IN THIS RETAIL SPACE. THE DRAWING IS NOT INTENDED FOR USE AS A CONSTRUCTION DOCUMENT. 05/11/2011 05/04/2011 04/28/2011 03/30/2011 01/03/2010 CTU FINAL ADVANCE M2 CTU REVISED INITIAL ADVANCED MOVE2 CTU SUBSTITUTED AISLE FIXTURING FOR GLASS CTU REVISED RETAIL SPACE - INITIAL ADVANCE M2 PLAN CTU INITIAL ADVANCED M2 PLAN EXISTING RESTROgf1 EXISTING RESTROO� 24' INSIDE CORNER E TI/EP EXISTING STOCKROOM EXISTING DOORWAY CONDITIONS u_ 2 U ot 10) IU I 1u) 7< '0) 10 T 10) l u) 10 10 3' -8„ U z O CLASSIC CO NTER- ROW LASSIC COUNTER -13 ROW LASSIC COUNTER -13 ROW SHOEBOX - 13 ROW H BLANKS-/ x-99 CENT / POST ``"=`"'" AID � CARDS, 41) 1 / BOXED CARDS / —MAHOG L/ SUN GREET - EDG MTI-IR � FRESH INK / CHRISTIAN-7/ EXPRESS SOUND / IMAGE ART./ / SEASONAL COUNTER-13 ROW. SEASONAL COUNTER -13 ROW n� QQ l 36 "X24" \ 72 "H / GLASS BARON VENDOR CASES TO MATCH HMK CASHIERING UNITS 1 7:— SPED -" -1 1 (DAVINCI) 1 L 95X481 J Y,._. _ -- Jam _I/ A -SPEC STIC ' S (JOURNALS) SEASONAL COUNTER -13 ROW BOOKS AA-PUZZLES / 1 . ALBUMS 1NEDD OCC`" ABY STATIONERY kr ' 4" 4- JEWELR� L (24X36) VENDOR CASES TO MAT.. H K. C_A HI RI G\JNI Ma.), --/JEWEL/- - CHRISTMAS GIFT WRAP - /KIDS //- DISNEY cos J g VENDOR CASES TO MATCH HMK EASHIE ING -UNITS FOS CENTER' FEATURE ecosS tA P 0N rl - -1' E i11E-RGENC Y Lsai4TI -7' A -SP /- (T-± ITE) (WOMEN'S FASHION) A-SPECIALTY 0 a Fee -,i A -SP (LIGHT HOUSE) !06•L.( II? C. - 'VIDEO/- 0 a A 1 AA -SPI KEEPSAKE ORNAMENT§ ORNAMENTS IN THE SPOTLIGHT li IL FELE ::V Permit NA., P tI ` ��v Plan review approval is subject to errors Approval of construction documents do the violation of any adopted code or o of approved Fie • . py and cond'I i • ns is By Ze/' 2q�f( Date:. II II o, (n > 03 S POWER WERI §z City Of Tukwila BUILDING DIVISIO I1� a id omissions. not authorize ance. Receipt cknowledgcd: EXISTING FIRE CORRIDOR 1- fi"tll3lddW�W211 3ldVW / V L 31dV11- / VIOS'VI / 1A211. 3ldVW STATIONERY S NOTES v ! 3ld'VW-A-WtJl 31d'VW oat. 3ldVW dIOsv _. ,' bl 3ld Vi /WSJ 3ldVW / W?J1 31d`d 1 GIFTS REV SIONS No changes shall tie made to the scope of work without prior approval of Tukwila Bui ding Division- ; NOTE: {=revisions will reluire a new plan submittal end may include additional plan review fees. W2! L 3ldVW VIOSVd W21.1. 21c1 VIA1 / WzIJ. 3ldVW-7' IN THE SPOTLIGHT WALL CATEGORY SIGN, TYP, FINISHES AND MATERIALS LEGEND BENJAMIN MOORE CHINA WHITE 141 -74 = PAINT (P1) BENJAMIN MOORE CHINA WHITE 14I -74 = PAINT (P2) ANTIQUE WHITE = PAINT (P3) BENJAMIN MOORE ACADIA WHITE AC -41 = PAINT (P4) APPROVED FINISH TO MATCH MALL NEUTRAL COLORS = PAINT (P5) KENSINGTON MAPLE BY WILSONART, 1410776 -60 = VALANCE /FASCIA (VI) QUARRY CAST BY FORMGLAS, STANDARD TEXTURE = BASE (81) MANNINGTON BARACOA, M22451 -001A, BRICK INSTAL., 24X24 = CARPET (C1) N/A = WALK -OFF MAT (W1) DALTILE, 4X8 UNION SQUARE, US0148IP = TILE (T1) MAPEI u05, SANDED CHAMOIS, 14999962310 = GROUT EXISTING CEILING: REPAIR /PAINT AS NEEDED = CEILING TILE (401) BACK PANEL (BPI) = MAPLE BACKPANEL BACK PANEL (BP2) 1 STRIPED BACKPANEL LAMINATE (L1) = DESIGNER WHITE BY WILSONART, 1,D354 -60 LAMINATE (L2) = KENSINGTON MAPLE BY WILSONART, 3:10776 -60 FURNITURE (S1) = KENSINGTON MAPLE BY WILSONART, 1410776 -60 DOOR (D1) I. EXISTING QUARRY CAST (QC1) = N/A WINDOW GLAZING = EXISTING WINDOW FRAMEWORK = EXISTING ROLL UP GRILLE = N/A MOULDING = EXISTING STOCKROOM = RETAILER TO DETERMINE FINISHES 00027880 ADVANCED MARK'S HALLMARK 144 SOUTHCENTER MALL, rt TUKWILLA, W THIS FLOORPLAN RETAIL SQ FT TOT LF TARGET TOTAL LF HMK LF TARGET HMK LF GRT LF TARGET GREET LF ALLIED LF 3130 569 560 341 395 205 253 165 GOLD CROWN STANDARDS RETAIL SQ FT TARGETED LF MIN HMK % MIN HMK LF MIN GRT % OF HMK MIN GREET LF <2000 236 130 2000 -2500 364 - 455 65% 236 -295 55% 130 -162 2501 -3000 455 - 545 60% 273 -327 60% 164 - 196 3000 -3500 546 - 636 60% 327 -382 60% 196 - 229 3501 -4500 637 - 818 55% 350 -450 60% 210 - 270 >4500 450 270 RECEIVED MAY 25 2011 PERMIT CENTER S 1= "A AT E PiEi MIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVIS N A Check mark in the box below indicates the Hallmark Retailer and the Hallmark Field Repre- sentative agree that this MP when provided to OME C /S, constitutes the FINAL ordering document from which fixtures and product will be determined. ORDER FROM THIS MP INITIALS DATE GENERAL INFORMATION A Intent of this drawing set is to show the relationship of design elements that are necessary for use in this retail space. THE DRAWING IS NOT INTENDED FOR USE AS A CONSTRUCTION DOCUMENT. The retailer is responsible for obtaining additional design consulting services for resolving outstanding architectural, mechanical and electrical design issues relating to the site and all applicable national and local codes and regulations governing the site of the project. Hallmark Marketing Corp. occepts no responsibility for construction costs or changes required by code requirements, site conditions or substitutions or changes In equipment shown on these plans. B Spatial dimensions shown on these plans are based on the current available information. Hallmark Marketing Corp. is not responsible for investigating actual site conditions or obtaining actual measurements for construction. C The retailer is responsible for maintaing minimum aisle widths and exit ways in accordance with all applicable laws and regulations. D The Hollmark mounting strip ("Z" bor) is located 77" above finished floor (high point) to the bottom of the strip, and 109 1/4" above finished floor to the bottom of the strip when required. E Unless noted otherwise on the merchandise plan, Hallmark Marketing Corporation's interpretation of the current American with Disabilities Act ( "ADA ") Accessibility Guidelines has been applied with respect to the following floor plan clearances for public access inside the premises: — Minimum clearance of doorways, fixtures, walls and columns — General spatial requirements for proposed restrooms In addition, a transaction counter meeting current ADA Accessibility Guidelines is shown. Any changes by retailer offecting these aspects of the merchandise plan should be reviewed with a design consultant to confirm compliance with the ADA Accessibility Guidelines. WALL DEPTH : 18IN AISLE DEPTH : 18IN VALANCE SYSTEM TYPE : MOVE CEILING HEIGHT : 14' -0" STORE TYPE: MALL PROGRAM: ADVANCED M2 BY: CTU REV DATE: 05/11/2011 REV DESC:FINAL ADVANCE M2 1 2' 4' PROJECT TYPE: RELOCATION DESIGN PHASE: FINAL EST. LEASEHOLD SQ. FT. 3800 RETAIL SQ. FT. 3130 ACCOUNT #: 00027880 Store Planning Studio MARK'S HALLMARK 4 SOUTHCENTER MALL, rt TUKVVILLA, WA ORIG. DATE: 01/03/2011 DESIGNED BY: CTU DRAWN BY: CTU SCALE: 1/4 " -1' -0" MP MERCHANDISE PLAN ELECTRICAL NOTES: NOTE: UNLESS OTHERWISE NOTED, CONTRACTOR TO PROVIDE AND INSTALL. FOLLOWING ITEMS WHEN SHOWN ON ELECTRICAL PLAN. Qi TRENCH AND /OR CONDUIT TO ELECTRICAL PANEL, IF NECESSARY. ®VERIFY LOCATION AND DIMENSIONS OF EXISTING ELECTRICAL PANEL BOARD (EP). VERIFY EXISTING CAPACITY AND UPGRADE AS REQUIRED. PANEL. MUST HAVE BUILDING GROUND. DUPLEX ISOLATED RECEPTACLE OUTLET MOUNTED AT 93" A.F.F. TO CENTERLINE OF BOX. LINK ALL HUTCHES TO ISOLATED CIRCUIT ALLOWING CIRCUIT TO BE TURNED OFF DURING NON-BUSINESS HOURS. 0(1) METAL RECEPTACLE STRIP W /BUILT -IN SURGE PROTECTOR, LIGHTED ON /OFF SWITCH W /STATUS INDICATOR, CIRCUIT BREAKER, SIX (6) RECEPTACLES AND SIX -FOOT CORD VV/PLUG. ORIENT GROUNDING PINS TO ALIGN VV/CENTERLINE OF STRIP. RECEPTACLE STRIPS SHALL BE RATED FOR 15A, 125 VAC, 60 HZ, TO MEET U.L. STANDARD 1449. ®1" DIA. CONDUIT WITH NECESSARY PULL BOXES AND PULL STRINGS FROM REGISTER LOCATION TO HUB LOCATION IN BACKROOM. ELECTRICAL CONTRACTOR TO PROVIDE SUFFICIENT PULL BOXES ALONG CONDUIT FOR ROUTING. Of DIA. CONDUIT WITH NECESSARY PULL BOXES AND PULL STRINGS FROM REGISTER LOCATION TO HUB LOCATION AT BACKUP REGISTER. TELEPHONE NOTES: ®ROUTE PER CODE THROUGH CONDUIT IN NOTE 5 FOR PHONE JACKS AND POSX MODEM PHONE LINES WITH MULTIPLE PHONE JACKS AS REQUIRED BY RETAILER FOR INSTALLATION OF POSX SYSTEM. RETAILER TO COORDINATE LOCATION OF TWO (2) PHONE JACKS WITH TELEPHONE CONTRACTOR. ()RETAILER RESPONSIBLE FOR CONTRACTING PHONE SYSTEM INSTALLATION TO MEET REQUIREMENTS OF THE POSX ACCOUNT AGREEMENT. ®CONVENIENCE TELEPHONE OUTLET: 3/4" CONDUIT WITH NECESSARY PULL BOXES AND PULL STRINGS. ROUTE TO TELEPHONE PANEL LOCATION AT STOCKROOM (MTTB). MOUNTED HORIZONTAL WITH TOP OF TELEPHONE BOX AT 0' -4" (4 INCHES) A.F.F. 10 POSX MODEM PHONE LINE TO BE CONNECTED TO UNPUBLISHED PHONE LINE OR CREDIT AUTHORIZATION LINE (VERIFY WITH STORE OWNER). DO NOT CONNECT TO FAX, PROGRAM ROLLOVER SYSTEM OR PUBLISHED PHONE LINES. NOTE: INTENT OF THIS DRAWING SET IS TO SHOW THE RELATIONSHIP OF DESIGN ELEMENTS THAT ARE NECESSARY FOR USE IN THIS RETAIL SPACE. THE DRAWING IS NOT INTENDED FOR USE AS A CONSTRUCTION DOCUMENT, EXISTING RESTROOM EXISTING RESTRO r (') L EXISTING RESTROOM EXISTING - RESTROO 24' INSIDE CORNER 15' -2" / -MAPLE TRIM / MAPLE TRM / MAPLE TRM 1 E T co NOTE: VERIFY ELECTRICAL AND CABLING WITH OWNER PRIIOR TO INSTALLATION. 05/11/2011 CTU ADJUST ELECTRICAL FOR FINAL M2 04/04/2001 CTU REVISED RETAIL SPACE - INITIAL EC PLAN 02/08/2011 CTU INITIAL ELECTRICAL PLAN EXISTING STOCKROOM ELECTRICAL TO REMAIN. OWNER TO MAKE ANY CHANGES. 0 u_ 1u) 10 1(n 10 lu 10 Fri lug 10 1 1 1 1 l u) 10 1 EXISTING FIRE CORRIDOR 20' -0" 12' 0" 8' 0" 8' 8" FASCIA / MAPLE TRM / MAPLE TRM / MAPLE TRM-/— FASCIA / MAPLE TRM / MAPLE TRM / MAP E TRM / MAPLE TRM_ - FASCIAS -MAPLE TRM / MAPL TRM-/ tV to w VERIFY COLUMN SIZE AND LOCATION, TYP. 7' 6" 19' -5° • %Win `Ir 11, 11: II 11 ira u • 11 POSX NOTES: 11 RETAILER SUPPLIED ETHERNET LAN CABLE MOUNTED INSIDE CASH WRAP FIXTURE. CABLE THROUGH BASE OF FIXTURES TO WALL. CONTINUE ROUTING VIA CONDUIT AT PULL BOX TO HUB. SEE NOTE 5. (DQUADPLEX ISOLATED GROUND OUTLET MOUNTED 15" A.F.F. TO CENTERLINE OF BOX. ISOLATED CIRCUIT TO ON 24 HOURS. 13 ROUTE POSX PRE - CONNECTED ETHERNET LAN CABLES) TO BACKROOM HUB LOCATION. THE INSTALLING CONTRACTOR MUST MEET REQUIREMENTS SPECIFIED IN "INSTRUCTIONS FOR INSTALLING THE 200 -FOOT POSX /PC ETHERNET LAN CABLE" FROM THE POSX STORE READINESS PACKET. 14 RETAILER SUPPLIED POSX BACKUP SERVER REGISTER. DUPLEX RECEPTACLE MOUNTED FLUSH WITH CEILING CS CS q‘ % SO CS CS — - CS 14 c; — -+I- CS CS — CS CS 20 AMP/110V QUADPLEX ' RECEPTACLE ��"ii• CS �S SO CS 110V RECESSED OR SUACE p' MOUNTED DUPLEX WALL OUTLET, CONTRACTOR TO INSTALL PULL ..% BOXES AT REGISTER AND HUB LOCATIONS AS SHOWN, AND TO PROVIDE SUFFICIENT PULL BOXES ALONG CONDUIT FOR ROUTING. MOUNTED 1- IO2IZONTALLY WITH THE CENTER OF BOX AT 116' A.F.F. — (I 110V RECESSED OR SURFACE ``�`I MOUNTED DUPLEX OUTLET, MOUNTED HORIZONTALLY WITH THE CENTER OF BOX AT 98" A.F.F. ® tV to w VERIFY COLUMN SIZE AND LOCATION, TYP. 7' 6" 19' -5° • %Win `Ir 11, 11: II 11 ira u • 11 POSX NOTES: 11 RETAILER SUPPLIED ETHERNET LAN CABLE MOUNTED INSIDE CASH WRAP FIXTURE. CABLE THROUGH BASE OF FIXTURES TO WALL. CONTINUE ROUTING VIA CONDUIT AT PULL BOX TO HUB. SEE NOTE 5. (DQUADPLEX ISOLATED GROUND OUTLET MOUNTED 15" A.F.F. TO CENTERLINE OF BOX. ISOLATED CIRCUIT TO ON 24 HOURS. 13 ROUTE POSX PRE - CONNECTED ETHERNET LAN CABLES) TO BACKROOM HUB LOCATION. THE INSTALLING CONTRACTOR MUST MEET REQUIREMENTS SPECIFIED IN "INSTRUCTIONS FOR INSTALLING THE 200 -FOOT POSX /PC ETHERNET LAN CABLE" FROM THE POSX STORE READINESS PACKET. 14 RETAILER SUPPLIED POSX BACKUP SERVER REGISTER. DUPLEX RECEPTACLE MOUNTED FLUSH WITH CEILING 8' 0" AT113 'V-v Rl! 31ldVW / WZI1 aldVV'I / VICS`d l_/ 'N 1 gld'dW 3ld'\W / NUL aldVW 7' 10" THERMOSTAT - T ION WITH STORE Q VERIFY LOCATION 1 OWNER 3P-15-E- ail "' q‘ % SO So OE SO SO STANDARD WITH MODULE SURFACE CENTERLINE NOTE CONVERSION CONVERSION BOX CIRCUITS. ': . SO SO SO i I 20 AMP/110V QUADPLEX ' RECEPTACLE SO 90 TELPONE JACK - RECESSED FLOOR AS REQUIRED SO 110V RECESSED OR SUACE p' MOUNTED DUPLEX WALL OUTLET, CONTRACTOR TO INSTALL PULL ..% BOXES AT REGISTER AND HUB LOCATIONS AS SHOWN, AND TO PROVIDE SUFFICIENT PULL BOXES ALONG CONDUIT FOR ROUTING. MOUNTED 1- IO2IZONTALLY WITH THE CENTER OF BOX AT 116' A.F.F. — (I 110V RECESSED OR SURFACE ``�`I MOUNTED DUPLEX OUTLET, MOUNTED HORIZONTALLY WITH THE CENTER OF BOX AT 98" A.F.F. 8' 0" AT113 'V-v Rl! 31ldVW / WZI1 aldVV'I / VICS`d l_/ 'N 1 gld'dW 3ld'\W / NUL aldVW 7' 10" THERMOSTAT - T ION WITH STORE Q VERIFY LOCATION 1 OWNER 110V RECESSED OR SURFACE C X OUTLET, NT DUPLE ET � MOUNTED MOUNTED HORIZONTALLY WITH THE CENTER OF BOX AT 89" AF,F. ail "' 20 AMP /110V QUADPLEX RECESSED FLOOR OUTLET WITH ISOLATED GROUND. MODEM PI-ONE JACK - RECESSED WALL AS REQUIRED — ETHERNET LAN HUB - SUPPLIED AND INSTALLED BY HALLMARK POSX INSTALLATION TEAM. GENERAL CONTRACTOR TO INSTALL 24 "X24 "X3/4" FR PLYWOOD MOUNTING BOARD AT 15" A.F.F. TO CENTER. J Q 1 STANDARD WITH MODULE SURFACE CENTERLINE NOTE CONVERSION CONVERSION BOX CIRCUITS. ': A "RELOC (2CM- REQUIRES �1�i1 1 � r : / 2X4 HANDY CONVERSION 120 -E21)' MOINTEO OF BOX MODULE MODULE TWO "‘ (� RELOC CONVERSION MODULE A.F.F. HANDY (SURFACE BOX PACE UP AT 89" A.F.F. HANDY (2) 20 AMP 1 AT Q89" BOX MOUNT) NOT USED 110V RECESSED OR SURFACE D MOUNTED DUPLEX OUTLET, MOUNTED I- IORIZONTALLY WITH THE CENTER OF BOX AT 15" A.F.F. iii 20 AMP/110V QUADPLEX ' RECEPTACLE ELECTRICAL PANEL - Oh EXISTING OR NEW SUPPLIED AND INSTALLED BY CONTRACTOR 111) E 1I0V RECESSED OR SURFACE MOUNTED DUPLEX WALL OUTLET, MOUNTED HORIZONTALLY WITH THE TOP OP BOX AT 0' -4" (4 INCHES) A.F.F. TELPONE JACK - RECESSED FLOOR AS REQUIRED r MAIN TELEPHONE TMINAL BOARD - EXISTING OR NEW 2 SUPPLIED AND INSTALLED BY CONTRACTOR 110V RECESSED OR SUACE p' MOUNTED DUPLEX WALL OUTLET, CONTRACTOR TO INSTALL PULL ..% BOXES AT REGISTER AND HUB LOCATIONS AS SHOWN, AND TO PROVIDE SUFFICIENT PULL BOXES ALONG CONDUIT FOR ROUTING. MOUNTED 1- IO2IZONTALLY WITH THE CENTER OF BOX AT 116' A.F.F. TELEPHONE JACK - RECESSED ® WALL AS REQUIRED (I 110V RECESSED OR SURFACE ``�`I MOUNTED DUPLEX OUTLET, MOUNTED HORIZONTALLY WITH THE CENTER OF BOX AT 98" A.F.F. ® 20 AMP /110V DUPLEX RECESSED FLOOR OUTLET. ® MODEM PHONE JACK - RECESSED FLOOR AS REQUIRED NOT USED 16' 0" MIL ldW4 / VICSVd--/-1A21 L 21dVW / W21f gldVW / W211 aldvW- --v i �ldb'W��`dICS Vd-�LWZI 1 20' -0" 1 ,; 16' 0" dldVW ELECTRICAL INFORMATION A The purpose of the electrical plan is to show the total rumber and location of outlets and Reloc modules required for Hallmark fixturing and cosh registers. All other electrical requirements are to be determined by the Retailer and their electrical consultant, and shall conform to all applicoble lows and regulations. B These documents do not identify how the Retailer intend: to purchase the electrical fixtures (by the Retailer, by the Retailer through Hallmark, or by the contractor for the Retailer, etc.). It is the responsibility of the retailer to communicate this to their electrical consultant C These drawings are generally diagrammatic and indicate the general orrangement of the equipment and wiring of the elements shown. D The " Reloc" manufactured wiring system incorporoted witlin Hallmcrk's basic wirin g system is designed to meet or exceed the requirements of the bboratory standard for Safety #183 for installation in accordance with article #604 of he National Electrical Code. Local code inspection authorities may or may not permit its uje. The retailer and their electrical consultant are responsible for checking with local code mthorities to determine if this wiring system is acceptable. This must be done prior to the Retailer ordering the Hallmark basic fixtures. HALLMARK MARKETING CORP, CANNOT GUARANTEE LOCAL AUTHORITY APPROVAL OF THE RELQC WIRING SYSTEM. E The engineer of record shall assign branch circuits to niet the intent of these documents. Where receptacles reference the same branch number, they shall be connected together to the some circuit breaker in the panelboard. fhe electrical contractor shall prepare o permanent panelboard directory showing circuit assignments as installed. Circuits designated to be left on continually shall be grouped toTther on adjacent circuit breakers and equipped with locking clips if allowed by local code. F If permitted by local codes, the use of 12/3 MC cable is recommended for all branch circuits. • GENERAL INFORMATION A Intent of this drawing set is to show the relationship of design elements that are necessary for use in this retail space. THE DRAWING IS NOT INTENDED FOR USE AS A CONSTRUCTION DOCUMENT. The retailer is responsible for obtaining additional design consulting services for resolving outstanding architectural, mechanical and electrical design issues relating to the site and all opplicable notional and local codes and regulations governing the site of the project. Hallmark Marketing Corp. accepts no responsibility for construction costs or changes required by code requirements, site conditions or substitutions or changes in equipment shown on these plans. 8 Spatial dimensions shown on these plans are based on the current available information. Hallmark Marketing Corp. is not responsible for investigating actual site conditions or obtaining actual measurements for construction. C The retailer is responsible for maintaing minimum aisle widths and exit ways in accordance with all applicable lows and regulations. D The Hallmark mounting strip ( "2" bar) is locoted 77" above finished floor (high point) to the bottom of the strip, and 109 1/4" above finished floor to the bottom of the strip when required. E Unless noted otherwise on the merchandise plan, Hallmark Marketing Corporation's interpretation of the current American with Disabilities Act ( "ADA ") Accessibility Guidelines hos been applied with respect to the following floor plan clearances for public access inside the premises: - Minimum clearance at doorways, fixtures, walls and columns - General spatial requirements for proposed restrooms In addition, a transaction counter meeting current ADA Accessibility Guidelines is shown. Any changes by retailer affecting these aspects of the merchandise plan should be reviewed with a design consultant to confirm compliance with the ADA Accessibility Guidelines. WALL DEPTH : 18IN AISLE DEPTH : 18IN VALANCE SYSTEM TYPE : MOVE CEILING HEIGHT : 14' -0" STORE TYPE: MALL PROGRAM: ADVANCED M2 DUPLEX RECEPTACLE MOUNTED FLUSH WITH CEILING REVIEWE1570 R CODE COMPLIANCE APPROVED JUN 2 3 2011 City of Tukwila BUILDING DIVISION ts oft-14 (0 BY: C I U REV DATE: 05/11/2011 RECEIVED MAY 25 2011 IPA',; ITCENTER REV DESC :ADJUST INITIAL ELECTRICAL PLAN FOR FINAL M2 PROJECT TYPE: RELOCATION DESIGN PHASE: FINAL EST. LEASEHOLD SQ. FT. 3800 RETAIL SQ. FT. 3130 ACCOUNT #: 00027880 Store Planning Studio MARK'S HALLMARK rt4 SOUTNCENTER MALL, rt TUKWILLA, WA ORIG. DATE: 02/08/2011 DESIGNED BY: CTU DRAWN BY: CTU SCALE: 1/4 " =1' -0" ELECTRICAL PLAN EXIT/UTILITY LIGHTING Xf2 -1 LIGHTOLIER LED EXIST SIGN, WHITE, RED LETTERS BACK -UP EXIT UNIVERSAL MOUNT, EMERGENCY LLNUR W UC -4. LIGHTOLIER 2 LAMP, 4', T8 STRIP, 120/227V, CEILING MOUNT I 1 SW4S2321-IPFUNVCA UC -4E LIGHTOLIER 2 LAMP, 4', T8 STRIP, 120/227V, CEILING MOUNT -UP w,�rUy�,r� W/ EMERGENCY BACK SW4S232HPFUNVCA /V47 VALANCE LIGHTING DISCONTINUED FLUORESCENT LIGHT VMS LAMP: (2) 48' LAMPS, T8 /TI2, 3500K DISCONTINUED FLUORESCENT LIGHT VMSII LAMP: (2) 48" LAMPS, T8 /TI2, 3500K LAMP: (I) 48" LAMP, T8/T12, 3500K BASIC DISPLAY UNIVERSAL VALANCE DISPLAY SHELF SHELF LAMP: (I) 48" LAMP, T8/T12, 3500K VMS, VMSII AND BASIC VALANCE DISPLAY SHELVES PRIOR TO 3/99. FIELD VERIFY SHELF TYPE NOTE: STORE VALANCE TYPE IS LISTED IN THE DRAWING TITLEBLOCK ACCENT LIGHTING TR-2 LIGHTOLIER 2' TRACK, WHITE, WITH LIVE END MATCHING HARDWARE AS REQUIRED 6000 WH TR -4 LIGHTOLIER 4' TRACK, WHITE, WITH LIVE END • MATCHING HARDWARE AS REQUIRED 6004 W-1 LIGHTOLIER 8' TRACK, WHITE, WITH LIVE END TR -8 MATCHING HARDWARE AS REQUIRED 6008 WH LIGHTOLIER MULTIPOINT FLAT TRACK, WHITE 1 I 7619 WH -I-MR LIGHTOLIER TRACK HEAD, 35 WATT, WHITE M 6273BWHX3 LAMP: 35 WATT, HALOGEN SPOT TM LIGHTOLIER TRACK HEAD, WHITE, PAR38 RING 9022 WH v LAMP: 60 WATT, PAR38, HALOGEN SPOT B(ISTING AMBIENT LIGHTING TXISTINC EXISTING 1X4 FLUORESCENT LIGHT TO REMAIN �r 1� f = - C EXISTING 1X4 FLUORESCENT EMERGENCY LIGHT TO REMAIN EXI T / EXISTING 2X2 FLUORESCENT LIGHT TO REMAIN —XI�� f%/ r EXISTING 2X2 FLUORESCENT EMERGENCY LIGHT TO REMAIN )STING EXISTING 2X4 FLUORESCENT LIGHT TO REMAIN EX STING viii /% G 2X4 FLUORESCENT EMERGENCY EXISTING T FIN EXISTING 2X4 - I8 -CELL - PARABOLIC FLUORESCENT LIGHT. ■ ■■ If/ ■rig. //./ EXISTING EMERGENCY 2X4 - I8 -CELL -PARABOLIC FLUORESCENT LIGHT. tR.. Rk4'+'{' t, d"'> 4,- S ?'xR :5tlark0rin,,t�fu11,e,'+. ?',. 14AfXP +AV14,14 4n1 -se ;.t.:i;u':v.. r1,4 ,,;;;q: rv- (1.,19' t1 n :WI tcinYfp(}1a 401 t NOTE: INTENT OF THIS DRAWING SET IS If TO SNOW THE RELATIONSI -IIP OF DESIGN ELEMENTS THAT ARE NECESSARY FOR . USE IN THIS RETAIL SPACE. THE DRAWING +€ IS NOT INTENDED FOR USE AS A ,. ' CONSTRUCTION DOCUMENT. ,.,:.0°11Y'N 05 /11/2011 CTU REVISED AND ADJUST LTS FOR EXISTING CEILING 01/03/2011 CTU EXISTING CEILIING 8' -O" AFF / -MAPLE TRM / MAPLE TRM--/—MAPLE TRM 24' INSIDE cs - - cs - .1/V/V/P /// RI/J ViI/IVL/ / / /I/ Martairad NEW 2X4 FLUORESCENT LIGHT TO MATCH EXISTING 18 -CELL PARABOLIC TROFFERS, TYP. SCIA / MAPLE TM / MAPLE TRM / MAPLE TRM / FA.CIA / MAPLE TRM / MAPLE TRM / MAPLIE TRM / MAPLE TRM / FASCIA--MAPLE TRM / MAPL TRW/ 1 1 Wal, WI EVIVI %/.//I/. r.te% 074 ireAmmq CS V/V/ % / /.AU5I/ UI%7f/ /VJIGIC ISI =o ■ a :_•U .. CS II •- - -- ■!•mU• ono •• 0 EXIST NG RESTRO• E P NMI :MI ••• • • EXISTING RESTROO' 1 0 ■u -.0 NM •1 0 1(n 10 0 I <<= T1 i • NM ■ INI M■ •i111ui• ••-11 ■11 EXISTING FIRE CORRIDOR 1 muummo •iimuiii mom III mi!I• 1 MIN ■ 10 ■.tali ■I_N M ■I NM PO Iowa ■•% "r /.!%G � v MIN ••■ ■1■ ••• 111i111/ii- 11111111111111111 ■MIS■ 10 1 ■ ■__ 1110/%G III GC GO rQ 1111l�II� 1111 11 11 �I ■__� 1111111111.1M 111111111111111111 •.M11111111 •111.11.■ •••••• ■111 ■ _ 1111 ■ 0 0 0 ;J1 mum= �� = / /.D_Imom r11111111a=MA M�/�'/�EN 11111 11111111111111 EXISTING EXIT LIGHTS GC SD GO GO NI_ so _ ____,, _ r_l - 0 • 11 11 0 0 11 • 11 OI 0 u EXISTING EXIT L I GI -ITS AMBIENT LIGHTING LIGHTOLIER INCANDESCENT OPEN DOWNLIGHT 8600 B7054CCDP 1951 LAMP: 75 WATT RC -1 LIGHTOLIER COMPACT FLUORESCENT 8" OPEN DOWNLIGHT, 8037CCDP- 71421-U -1951 LAMP: 1 -42 WATT TRIPLE TUBE HORIZONTAL LAMP. RC -1E LIGHTOLIER COMPACT FLUORESCENT 8' OPEN DOWNLIGHT, W/ EMERGENCY BACK -UP 8037CCDP- 71421-UEM -1951 LAMP: 1 -42 WATT TRIPLE TUBE HORIZONTAL LAMP RC -2 LIGHTOLIER COMPACT FLUORESCENT 8' OPEN DOWNLIGHT, 8038CCDP- 8242HU -1951 LAMP: 2 -42 WATT TRIPLE TUBE HORIZONTAL LAMP RC -2E LIGHTOLIER COMPACT FLUORESCENT 8" OPEN DOWNLIGHT, W/ EMERGENCY BACK-UP 8038CCDP- 82421-UEM -1951 LAMP: 2 -42 WATT TRIPLE TUBE HORIZONTAL LAMP FED O AMBIENT LIGHTING LIGHTOLIER INCANDESCENT ADJUSTABLE PENDANT, MATTE BLACK, FSPEX30I0 -19, BOTTOM OF SHADE 7-0" AFF LAMP: 9 WATT, COMPACT FLUORESCENT 0 O LIGHTOLIER INCANDESCENT 2 LIGHT PAR38 ADJUSTABLE RECESSED DOWNLIGHT, PB2P3810WL LAMP: 25 WALL PAR38 WIDE FLOOD 40, METAL HALIDE O LIGHTOLIER INCANDESCENT 1 LIGHT PAR38 ADJUSTABLE RECESSED DOWNLIGHT, PBIP3810WL LAMP: 25 WALL PAR38 WIDE FLOOD 40, METAL HALIDE PT -2X4 LIGHTOLIER 2X4 PRISMATIC LENS FLUORESCENT LIGHT 3 LAMP T8 XP2GVA332UNVH3 LIGHTOLIER 2X4 PARABLOIC LENS FLUORESCENT LIGHT 3 LAMP T8 DPA2GI8LS332UNVH3 PERIMETE2 LIGHTING TR -2 LIGHTOLIER 2' TRACK, WHITE, WITH LIVE END MATCHING HARDWARE AS REQUIRED 6000 WH TR -4 LIGHTOLIER 4' TRACK, WHITE, WITH LIVE END MATCHING HARDWARE AS REQUIRED 6004 WH TR -8 LIGHTOLIER 8' TRACK, WHITE, WITH LIVE END MATCHING HARDWARE AS REQUIRED 6008 WH WW LIGHTOLIER WALL WASHER HEAD, 70 WATT MI-1, WHITE 8292 WEWH INC LAMP: 70 WATT, METAL. HALIDE, DOUBLE ENDED T6 CN1 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 3 2011 City of BUILD NGTDIVISIO N + 12' -4" AFF VERIFY EXISTING CEILING DOWN SPOTS, TYP. 11"•1 A'kdl RPM /HMI gldVVJ / VIO . Vd_/ J. 21dVVI Wt1131dVVV BUILD OUT WALL FLESH WITH COLUMN FACE. W�I1 aldVN / 1A211 9ld'dW / VICS'dd W211 aldVW / W�I 9idWW / WZI.L ld`dW / Nal 31dVW `dICS'dd �ldWI Will ;ldvw-7' + 1 o' -o" AFF LIGHTING GENERAL NOTES CEILING CI -1ANGE 1)11%-14(9 EXISTING CEILNG RECEIVED MAY 25 2011 PERMIT CENTER A The purpose of the reflected ceiling plan is tf show the type, number and location of the lighting fixtures required br the Hallmark fixturing and cash registers. Any additional fixtures and requirements are to be determined by the Retailer and their electrico consLltants and shall conform to all national and local codes and crdinanances. B These documents do not identify how the Retailer intends to purchase the lighting fixtures (by the Retailer, by the Eetailer through Hallmark, by the Contractor for the Retailer, etc.). It is the responsibility of the Retailer to communicate this to their lighting. consultant. GENERAL INFORMATION A Intent of this drawing set is to show the relationship of design elements that are necessary for use in this retail space. THE DRAWING IS NOT INTENDED FOR USE AS A CONSTRUCTION DOCUMENT. The retailer is responsible for obtaining additional design consulting services for resolving outstanding architectural, mechanical and electrical design issues relating to the site and all applicable national and local codes and regulations governing the site of the project. Hallmark Marketing Corp. accepts no responsibility for construction costs or changes required by code requirements, site conditions or substitutions or changes in equipment shown on these plans. B Spatial dimensions shown on these plans are based on the current available information. Hallmark Marketing Corp. is not responsible for investigating actual site conditions or ob taining actual measurements for construction. C The retailer is responsible for mointoing minimum aisle widths and exit ways in accordance with all applicable laws and regulations. D The Hallmark mounting strip ( "Z" bar) is located 77" above finished floor (high point) to the bottom of the strip, and 109 1/4" above finished floor to the bottom of the strip when required. E Unless noted otherwise on the merchandise plan, Hallmark Marketing Corporation's interpretation of the current American with Disabilities Act ( "ADA ") Accessibility Guidelines has been applied with respect to the following floor plon clearances for public access inside the premises: — Minimum clearance at doorways, fixtures, walls and columns — General spatial requirements for proposed restrooms In addition, a transaction counter meeting current ADA Accessibility Guidelines is shown. Any changes by retoiler affecting these aspects of the merchondise plan should be reviewed with a design consultant to confirm compliance with the ADA Accessibility Guidelines. WALL DEPTH : 18IN AISLE DEPTH : 18IN VALANCE SYSTEM TYPE : MOVE CEILING HEIGHT : 14' -0" STORE TYPE: MALL PROGRAM: ADVANCED M2 BY: CTU REV DATE: 05/11 /2011 REV DESC :REVIEW AND ADJUST LTS FOR EXISTING CEILING PROJECT TYPE: RELOCATION DESIGN PHASE: FINAL EST. LEASEHOLD SQ. FT. 3800 RETAIL SQ. FT. 3130 ACCOUNT #: 00027880 Store Planning Studio MARK'S HALLMARK 144 SOUTNCENTER MALL, rt TUKWILLA, WA ORIG. DATE: 01/03/2011 DESIGNED BY: CTU DRAWN BY: CTU SCALE: 1/4 " -1' -0" RC REFLECTIVE CEILING PLAN F -9 r-- CARPET ?? MMWWWW CARPET TO STOCK 5 FL. TRANSITION SCALE: N.T.S. .,riirii ci%iriiriiriii REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 3 2011 ENTRANCE FL. TRANSITION SCALE: N.T.S. F--I F2 ii SS(iif�f {fiiS(S�tSit {�4SSiS in SALES FLOOR FL. TRANSITION SCALE: N.T.R. ECEIVED MAY 252011 P , IT CENTER TRACTOR'S N e j LOOR FINISH NOTES WRITTEN DIMENSION NOT SCALE.DRAWINGS, AU. EXISTING CONDITIONS AND REPORT ANY OISCREPANO WITH THE PROPER IION OF WORK, T REPORT DISCREPANCIES DURING BIDDING PROCE OF CONSTRUCTION. EXTRAS WILL NOT BE ALLOWED COMPLIANCE CONDITIONS AFTER COMMENCEMENT OF CON PREFERENCE 0 ACTOR' AN DIMENSIONS. QQ VISIT J06 SITE TO VERIFY ONS BEFORE SUBMITTING BIDS. IRONS WHICH MAY INTERFERE ANT REPRESENTATIVE. 0 BEFORE START OR COOE ON. F -2 EXTERIOR CONC, SLAB THRESHOLD STOCKROOM TO EXIT FL, TRANSITION SCALE: N.T.S. AMT1CO FLOOR CLEANING PREP • ' . BRAVO SOLUTION AS PER THE INSTRUCTIONS NOTED s N THE BO . FOLLOW AU. SAFETY INSTRUCTIONS. PARTICULARL NOTING THAT A FLOOR CAN BECOME SUP' ' Y DURING THE STRIPPIN ' ''OCESS. APPLY PLENTY 0 :RAVO SOLUTION OVER A MANA ABLE AREA LOW 5 —I0 MINUTE ONTACT TIME EITHER MACHINE" SCRUB 1H BLUE II PAD ,- AQTAIE SOLUTION WITH MOP. 00 NOT ALLOW ' URRY TO DR ON FLOOR. EITHER REMOVE SLURRY WIN VAC ' M MACHINE OR MOP AND BUCKET. RINSE FLOOR TWICE Yi . - WATER. ALLOW TO DRY APPUCTION OF CAR COMPLETE SEALER LOAD MOP WITH CAREFREE C. TE ' • R (DO NOT USE THE SAME MOP USED TO APPLY PPING.) APPLY A THIN EVEN CO•. WITH OVERLAPPIN PASSES. ALLOW TO DRY APPROX. 30 MINU APPLY SECOND CO . AT 90 DEGREE TO FIRST, ALLOW TO DRY r PROX. 30 MINUTES, D0 NOT BUFF 1 ` 24 HOURS. AFTER INSTALLATION NOTES AMTICO ST BE COVERED 1MTH HEAVY PAPER AFTER BEING STRIPP , BUFFED AND WAXED. (DO NOT USE HEAVY TAPE LIKE r. CT TAPE) USE MASKING TAPE T +:,C. TO WAX VCT IN STOCK ROOM AND TOILET ROOM W/ NERIC WAX PRIOR TO TURNOVER. 2867 Southcenter Mall Tukwila, WA 98188 smith ce. 1725 westlake ave. n. suite 210 seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith @smithco.org http://www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration El STATE OF WASHINGTON No. Date Issues By Check 1 03.31.08 2 04.18.08 PERMIT OWNER REVISIONS KLS KLS Project Name WESTFIELD SOUTHCENTER MALL Project Number 02008018.00 Description FLOOR PLAN Computer File CW05- 2008— A2.DWG Scale AS NOTED Template 4.3 (120101) All Ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of smith co. IIc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, *designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. IIc. A -2 Dewv2 pow