Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D11-343 - US COAST GUARD RECRUITING - TENANT IMPROVEMENT
U S COAST GUARD RECUITING 640 STRANDER BL Dl 1 -343 City ofkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov Parcel No.: 0005800037 Address: 640 STRANDER BL TUKW Suite No: • DEVELOPMENT PERMIT Project Name: U S COAST GUARD RECRUITING Permit Number: D11 -343 Issue Date: 12/05/2011 Permit Expires On: 06/02/2012 Owner: Name: BC PARTNERS LLC Address: C/O MK PROPERTY SVC LLC , PO BOX 997 98065 Contact Person: Name: CHUCK LINDBERG Address: 12920 SE 95 WY , NEWCASTLE WA 98056 Contractor: Name: Address: Contractor License No: Phone: 425 255 -5467 Phone: Expiration Date: DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT TO EXISTING VACANT STOREFRONT SPACE. NO MODFICATION TO EXISTING EXTERIOR SHELL BUILDING. Value of Construction: $79,170.00 Fees Collected: $2,094.06 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: VB Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY * *continued on next page ** doc: IBC -7/10 D11 -343 Printed: 12 -05 -2011 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N 1 • Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non - Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I - S--� CI I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: This P ermit shall become null and void if the w k is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date/} S �r PERMIT CONDITIONS: 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. 6: New suspended ceiling grid and light fixture installations shall meet the non - building structures seismic design requirements of ASCE 7. doc: IBC -7/10 D11 -343 Printed: 12 -05 -2011 7: All construction shall be done in conform. with the approved plans and the requiremef the International Building Code or International Residential C International Mechanical Code, Washingto e Energy Code. 8: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 15: ** *FIRE DEPARTMENT CONDITIONS * ** 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 17: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3 -2.1) 18: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 nun) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mrn). (IFC 906.7 and IFC 906.9) 19: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 20: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 21: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 22: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 23: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 24: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) doc: IBC -7/10 D11-343 Printed: 12 -05 -2011 26: Aisles leading to required exits shall bil,vided from all portions of the building and 0equired width of the aisles shall be unobstructed. (IFC 1013.4) 27: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 28: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13- 8.6.5.3.3) 29: All new sprinlder systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2050). 30: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 32: New and existing buildings shall have approved address numbers, building numbers or approved building identification placed in a position that is plainly legible and visible from the street or road fronting the property. These numbers shall contrast with their background. Address numbers shall be Arabic numbers or alphabet letters. Numbers shall be a minimum of 4 inches (102mm) high with a minimum stroke width of 0.5 inch (12.7mm). (IFC 505.1) 33: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 34: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 35: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IBC -7/10 D11 -343 Printed: 12 -05 -2011 CITY OF TUKS A Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Pe Mechanical Permit No. Plumbing/gas Permit No. Public Works Permit No. Project No. or of ce use on Applications and plans must be complete in order to be accepted for plan review: Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 640 Strander Blvd Tenant Name: U.S. Coast Guard Recruiting Property Owners Name: BC Partners, LLC Mailing Address: CIO MK Property Services, P.O. Box 997 King Co Assessor's Tax No.: 0005800037 Suite Number: N/A Floor: 1st New Tenant: 0 Yes El „No Snoqualmie City 98065 State Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Chuck Lindberg Mailing Address: 12920 SE 95th Way E -Mail Address: edi- chuck @gwestoffice.net Day Telephone: (425) 255 -5467 Newcastle City wa State 98056 Fax Number: (425) 271 -1456 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: Enriched Designs, Inc. Mailing Address: 12920 SE 95th Way Contact Person: Chuck Lindberg E -Mail Address: edi- chuck @gwestoffice.net Contractor Registration Number: CC01- ENRCD112809 Newcastle City State Day Telephone: (425) 255 -5467 Fax Number: (425) 271 -1456 98056 Zip Expiration Date: 07/13/2013 ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: urban solutions studio, IIc . (Architect of Record - Gary B.Barber) Mailing Address: 1555 Union Ave. NE, Unit # 66 Renton Contact Person: Warwick Ashley E -Mail Address: warwick. ashley @urbansolutionsstudio.com 98059 City State Zip Day Telephone: (206) 734 -4422 Fax Number: ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: N/A Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip BUILDING PERMIT INFORMATIO0206 -431 -3670 Valuation of Project (contractor's bid price): $ 79,170.00 Existing Building Valuation: $ 5,500,000.00 Scope of Work (please provide detailed information): Interior tenant improvement to existing vacant storefront space. No modification to existing exterior shell building. Exterior sign permit to be made in separate submittal. Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No 1f 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Saf ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1st Floor 2,500 2,500 0 0 V -B B 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes ", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes No 1f 'yes', attach list of materials and storage locations on a separate 8 -1 /2 "x 11" paper including quantities and Material Saf ata Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. PERMIT APPLICATION NOTES — Applicable to all permits in this application Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official May grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103:4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING / �, � �7 NT: Signature: �. Date: / :`l Print Name: et, i. c L z A../' Day Telephone: 2- s S G Mailing Address/c2.1) ce)d_7. - Arel ca.4- 7el _ - al e City State 376 Zip IDate Application Accepted: 10 101 (1 Date Application Expires: oyl��liy Staff Initials: H: Wpptientione\Fonns- Applicr>bom On Line \2010 Applications \7 -2010 - Permit Application.doc Revised: 7 -2010 bh Page 6 of 6 • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0005800037 Permit Number: D11-343 Address: 640 STRANDER BL TUKW Status: APPROVED Suite No: Applied Date: 10/19/2011 Applicant: U S COAST GUARD RECRUITING Issue Date: Receipt No.: R11 -02615 Initials: User ID: WER 1655 Payment Amount: $1,270.90 Payment Date: 12/05/2011 08:31 AM Balance: $0.00 Payee: CHARLES LINDBERG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 01500G ACCOUNT ITEM LIST: Description 1,270.90 Account Code Current Pmts BUILDING - NONRES 000.322.100 STATE BUILDING SURCHARGE 640.237.114 Total: $1,270.90 1,266.40 4.50 doc: Receiot -06 Printed: 12 -05 -2011 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0005800037 Permit Number: D11-343 Address: 640 STRANDER BL TUKW Status: PENDING Suite No: Applied Date: 10/19/2011 Applicant: U S COAST GUARD RECRUITING Issue Date: Receipt No.: R11 -02284 Initials: User ID: Payee: JEM 1165 Payment Amount: $823.16 Payment Date: 10/19/2011 11:04 AM Balance: $1,270.90 CHARLES LINDBERG, ENRICHED DESIGNS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 319140 ACCOUNT ITEM LIST: Description 823.16 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 823.16 Total: $823.16 doc: Receipt -06 Printed: 10 -19 -2011 ti rs INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 IP" 0H-343 Project: (/.. r20 /1-6T"6iaf1 Type of I spection: <<JA- L..&u:f`J:4 Date Called: Address: ( /40' Srf ii- A 6 Special Instructions: . � � _/ Date Wanted:. ma,- ! - 2.S i ? . P.m. Requester: Alone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: (3r/ -P c17-7 04 r A44 -0 L (Inspect: 'Date: I-- 2-S -/ Z.--- REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ._n :. .. .ti a..A. s.0 • ....,. rani • .vr. -ss. .__n.r.. • ... — _ _ _ • . -Pe :t • • • INSPECTION RECORD Retain a copy with permit INSPECTION NO.. PERMIT NO. J it- 343 ' CITY OF' TUKWILA BUILDING DIVISION 6300Soutlicenter Blvd., #100, Tukwila. WA 98188 I. (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 . ti S CA S I G UA 0 Type of Inspection: 1.5,J: I 6 Address: ^ /� Date Called: (. ,1 Special,.lnstructions: - • • Date Wanted:1 2 4 � ( 1 -,La m� p.m. Requester: Phon. No_ G ` 45.g • t { ri :Approved per applicable codes. orrections required prior to approval. COMMENTS: (. ,1 4-1) ILA L eP Ar 1 j L k -u -er 1-4-m- . f r re- i -5p.ec ,)" • • • • ..._.. . c. Inspector: • REINSPECTION FEE REQUIR paid at 6300 Southcenter Blv Date: J D. Prior to next inspection. fee must be Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 01c —343 INSPECTION NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 y_ (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 PERMIT NO. Project: Typ f Inspection: Address: Ir Date Called: Special Instructions: • Date Wanted:+. �`.�a.m� _ ' p.m. Requester: Phone No: 7,0,9 -4 s �- 1 r 4 i LiApproved per applicable codes. Corrections required prior to approval. COMMENTS: ektN91--? Avr6 vk{ 1 te----,c9 --CI, r I 0 DAV (; 4 ` - `mi) f}- g- OJT- ! 605r i & iAre ---i No 17 f+r , 1 67 r & .1 , AEI P , 1 C k 1 I. a.lice ti , t o !-el -- Inspector: 'Date: 0 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 141.644•12094.ab .......-. 7. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 5 PERMIT NO. CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 vle (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: Address: • .6 40 s 7OIIOce Date Called: Special instructions: Date Wa ted: . / / G �/ z.-.- p Requester: Phone No: IApproved per applicable codes. -Corrections required prior to approval. COMMENTS: Gl.•lZu.t/6 - A/JP/?dVF� REINS ECTION FEE REQUIR -:s. Prior to ext inspection. fee must be . ard at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. . INSPECTION NO. INSPECTION RECORD Retain a copy with permit Dt l- 3t1) PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: )\S CCr -' C AttR7S Type of Inspection: Fb . . Address: (e7y0 ST R.. A4 t c rZ Date Called: r---t2A, A/Ea Special Instructions: Date Wanted:. a.m. Requester: Phone No: a- 04,- L-I SS —11,-,7 6 Approved per applicable codes. Corrections required prior to approval. /'.- COMMENTS: nspe Date: 12—'3-1 EINSPECTION FEE REQUIRED. Prior next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Jar INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ••••47-.WP � ..... ..," 0/1- 3113 1/-5- z3Zr PERMIT NUMBERS CITY OF TUKIUILA FIRE DEPARTMENT 444 Andover Park fast, Tukwila ,V1ea.98188 206= 575 -4407 Project: cA J c G T G. ...or r0,..„,.., !.: Type of Inspection: i`i /L F. V i Address: G `l .5T�n frOv.-L Suite #: 09 c' -' . Contact Person: /eery Special Instructions: / e. Phone No.: a.06 vs, -'iy7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: m S3 Sprinkler: . Fire Alarm: (Z) "- . "74V)..� ff.- / e. Gia f, :, A ©1 c4,,,..,4 I.qe r� v r r P✓ • .1 Needs Shift Inspection: m S3 Sprinkler: . Fire Alarm: Hrs.: Hood Duct; Monitor: 'Pre -Fire: Permits: _ ; ' Occupancy Type: Inspector: m S3 Date: 1 J, h z- Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from e City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address if Attn: otY Company Name: Address: City: State: I Zip: Word /Inspection Record Form.Doc T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 4 - s - �g Dig - 3 y3 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT - 444 Andover Park East, Tukwila, Wa. 98188 206- 575 -4407 Project: ratts-\ 614 �-& r o Typpee o -- CJV- --Qf f Inspection: Address: 6t (G) ., e J .p rr Suite #: Contact Person: Special Instructions: Pre -Fire: Phone No.: 4pproved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: k. E-6).-- Date: i 2_7-0 Hrs.: ,$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: 1 Zip: Word /Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • ..:3 • 3 • 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Project Summary PRJ -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address 640 Strander Blvd Date 10/18/2011 Tukwila, WA 98188 For Building Department Use Applicant Name: EDi Applicant Address: 12920 S.E. 95th Way, Renton, WA 98056 Applicant Phone: (206) 255 -5467 FILE COPY Permit r4o.. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 01 2011 City of Tukwila BUILDING DIVISION Cm O�TUKIMLA Or.T 19 2011 PERMIT CENTER 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary LTG -INT 2009 Washington State Energy code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Project Address 640 Strander Blvd Date 10/18/2011 Tukwila, WA 98188 For Building Department Use All other areas Applicant Name: Fan Applicant Address: 12920 S.E. 95th Way, Renton, WA 98056 Applicant Phone: (206) 255 -5467 Project Description ❑ Plans Included requirements. ❑ New Building ❑ Addition 11 Alteration Refer to WSEC Section 1513 for controls and commissioning Compliance Option Q Prescriptive QQ Lighting Power Allowance 0 Systems Analysis (See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.) Alteration Exceptions (check appropriate box - sec. 1132.3) ❑ No changes are being made to the lighting and space use not changed " Less than 60% of the fixtures new, installed wattage not increased, & space use not changed. " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts Maximum Allowed Lighting Wattage Location (floor plan /room #) Occupancy Description Allowed Watts per ft2""` Gross Intenor Area in ft2 Allowed x Area All other areas Office Space 0.92 2316 2131 Conf. Room 112 s.f. (<150 s.f. perTable 15 -1, footnote 7) 1.11 112 124 Open Office /Hall 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 9 91 819 " From Table 15 -1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts 2255 Proposed Lighting Wattage Location (floor plan /room #) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Lobby /Waiting 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 3 91 273 Welcome Center 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 1 91 91 Open Office /Hall 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 9 91 819 Closed Offices 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 4 91 364 Conf. Room 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 1 91 91 Mail /Copy 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 1 91 91 Storage 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 1 91 91 Break Rm. 2' x 4' Fluor. fixtures (exist. refitted w/ 3 - T8 lam; 1 91 91 Toilet - Mens Wall- mounted fixtures w/ 1 fluor. Lamp 1 46 46 Toilet - Women Wall- mounted fixtures w/ 1 fluor. Lamp 1 46 46 Hallway Rec. can fixtures w/ 1 fluor. lamp 3 46 138 Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts 2141 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T -8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts /Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Interior Lighting Summary (back) LTG -INT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Prescriptive Spaces Occupancy: Q Warehouse or Parking Garage 0 Other Qualification Checklist Note: If occupancy type is "Other' and fixture answer is checked, the number of fixtures in the space is not limited by Code. Clearly indicate these spaces on plans. If not qualified, do LPA Calculations. Lighting Fixtures: (Section 1521 ) 0.85 4 Check if 95% or more of fixtures comply with 1,2 or 3 and rest are ballasted. 1. Fluorescent fixtures with a) 1 or 2 two lamps, b) reflector or louvers, c) 5-60 watt T -1, T -2, T-4, T -5, T -8, or CFL lamps, and d) hard -wired electronic dimming ballasts. Screw -in CFL fixtures and tracking lighting do not qualify. 2. Metal Halide with a) reflector b) ceramic MH lamps < =150w c) electronic ballasts 3. LED lights. TABLE 15 -1 Unit Licthtina Power Allowance (LPA Use' LPA` (W /ft`) Use' LPA` (W/ft`) Automotive facility 0.85 Office buildings, office/administrative areas in facilities of other use types (including but not limited to schools, hospitals, institutions, museums, banks, churches)5 0.91 Convention center 1.10 Parking garages 0.20 Courthouse 1.10 Penitentiary and other Group 1 -3 Occupancies 0.90 Cafeterias, fast food establishments', restaurants/bars5 1.20 Police and fire stations 0.90 Dormitory 0.85 Post office 1.00 Dweling Units 1.00 Retain°, retail banking, mall concourses, wholesale stores (pallet rack shelving) 1.33 Exercise center 0.95 School buildings (Group E Occupancy only), school classrooms, day care centers 1.00 Gymnasia, assembly spaces 0.95 Theater, motion picture 0.97 Health care clinic 1.00 Theater, performing arts 1.25 Hospital, nursing homes, and other Group 1 -1 and 1 -2 Occupancies 1.20 Transportation 0.80 Hotel /motel 1.00 Warehouses 0.50 Laboratory spaces (all spaces not classified "laboratory" shall meet office and other appropriate categories) 1.62 Workshops 1.20 Laundries 1.20 Libraries' 1.20 Plans Submitted for Common Areas Only' Manufacturing facility 1.20 Main floor building lobbies' (except mall concourses) 1.10 Museum 1.00 Common areas, corridors, toilet facilities and washrooms, elevator lobbies 0.80 Footnotes for Table 15 -1 1) In cases in which a general use and a specific use are listed, the specific use shall apply. In cases in which a use is not mentioned specifically, the Unit Power Allowance shall be determined by the building official. This determination shall be based upon the most comparable use specified in the table. See Section 1512 for exempt areas. 2) The watts per square foot may be increased, by 2% per foot of ceiling height above 20 feet, unless specifically directed otherwise by subsequent footnotes. 3) Watts per square foot of room may be increased by 2% per foot of ceiling height above 12 feet. 4) For all other spaces, such as seating and common areas, use the Unit Light Power Allowance for assembly. 5) Watts per square foot of room may be increased by 2% per foot of ceiling height above 9 feet. 6) Reserved. 7) For conference rooms and offices less than 150ft2 with full height partitions, a Unit Lighting Power Allowance of 1.1 w /ft2 may be used. 8) Reserved. 9) For indoor sport tournament courts with adjacent spectator seating over 5,000, the Unit Lighting Power Allowance for the court area is 2.60 W/ft2. 10) Display window illumination installed within 2 feet of the window, provided that the display window is separated from the retail space by walls or at least three - quarter- height partitions (transparent or opaque) and lighting for free - standing display where the lighting moves with the display are exempt. An additional lighting power allowance is allowed for merchandise display luminaires installed in retail sales areas that are specifically designed and directed to highlight merchandise. The following additional wattages apply: i. 0.6 watts per square foot of sales floor area not listed in items ii and iii below; ii. 1.4 watts per square foot of furniture, clothing, cosmetics or artwork floor area; or iii. 2.5 watts per square foot of jewelry, crystal or china floor area. The specified floor area for items i, ii, or iii above, and the adjoining circulation paths shall be identified and specified on building plans. Calculate the additional power allowance by multiplying the above LPDs by the sales floor area for each department excluding major circulation paths. The total additional lighting power allowance is the sum of allowances for sales categories I, ii, or iii plus an additional 1,000 watts for each separate tenant larger than 250 square feet in area. The additional wattage is allowed only if the merchandise display luminaires comply with all of the following: (a) Located on ceiling- mounted track or directly on or recessed into the ceiling itself (not on the wall). (b) Adjustable in both the horizontal and vertical axes (vertical axis only is acceptable for fluorescent and other fixtures with two points of track attachment). This additional lighting power is allowed only if the lighting is actually installed and automatically controlled, separately from the general lighting, to be tumed off during nonbusiness hours. This additional power shall be used only for the specified luminaires and shall not be used for any other purpose. This additional lighting power is allowed only if the lighting is actually installed. 11) Provided that a floor plan, indicating rack location and heiaht. is submitted, the square footage for a warehouse may be defined. for 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Exterior Lighting;Summary LTG -EXT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info Proj Addres: 640 Strander Blvd Date 10/18/2011 Tukwila, WA 98188 For Building Department Use Area (ft2), perimeter (If) or # of items Name: Eoi Appl. Name 12920 S.E. 95th Way, Renton, WA 98056 Appl. Phone (206) 255 -5467 Project Description ❑ New ❑ Addition Refer to WSEC Section 1513 for controls ❑ Plans Included requirements. ✓ Alteration and commissioning Lighting Zone (as specified by Jurisdiction) Q Zone 1 Zone 2 Q Zone 3 Q Zone 4 Compliance Option Q Lighting Power Allowance 0 Systems Analysis Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/W motion sensor • Controlled by ❑ Exemption (list) Alteration Exceptions (check appropriate box - sec. 1132.3) and space use not changed. .1 No changes are being made to the lighting ❑ Less than 60% of fixtures are new, installed wattage not increased, & space use not changed. Tradable Maximum Allowed Lighting Wattage Base Site Allowance: Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft`), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Main Entry Select Zone Total Allowed Tradable Watts: Tradable Proposed Lighting Wattage (use mfgr listed maximum input wattage for luminaire.) Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Total proposed tradable watts may not exceed the sum of total allowed tradable watts plus Total Proposed Tradable Watts: the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non - tradable categories. Non - Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: Fixture Description Non - Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Non - Tradable Proposed Lighting Wattage Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non - tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non - tradable surfaces are less than the remaining site allowance. Total excess Non - Tradable watts: Site Allowance Balance: 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Exterior Lighting jSummary (back) LTG -EXT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential TABLE 15 -2B LIGHTING POWER DENSITIES FOR BUILDING EXTERIORS Revised December 2010 Specific area description Zone 1 500 W Zone 2 600 W Zone 3 750 W Zone 4 1300 W Base site allowance' Tradable Surfaces 2 Uncovered Parking Parking lots and drives Areas 0.04 W /ft2 0.06 W /ft2 0.10 W /ft2 0.13 W /ft2 Building Grounds Walkways less than 10 ft wide 0.7 W /linear foot 0.7 W/ linear foot 0.8 W/ linear foot 1.0 W/ linear foot Walkways 10 ft wide or greater Plaza areas Special feature areas 0.14 W/ft2 0.14 W /ft2 0.16 W /ft2 0.2 W/ft2 Exterior Stairways 0.75 W /ft2 1.0 W /ft2 1.0 W/ft2 1.0 W/ft2 Pedestrian tunnel 0.15 W /fie 0.15 W /ft2 0.2 W/ft2 0.3 W /ft2 Landscaping 0.04 W /ft2 0.05 W /ft2 0.05 W /ft2 0.05 W /ft2 Building Entrances and Exits Main entries 20 W/linear foot of door width 20 W/linear foot of door width 30 W/linear foot of door width 30 W/linear foot of door width Other doors 20 W /linear foot of door width 20 W /linear foot of door width 20 W/linear foot of door width 20 W /linear foot of door width Entry canopies 0.25 W /ft2 0.25 W/ft2 0.4 W /ft2 0.4 W /ft2 Sales Canopies Free standing and attached 0.6 W/ft2 0.6 W /ft2 0.8 W/ft2 1.0 W /ft2 Outdoor Sales Open areas' 0.25 W /ft2 0.25 W /ft2 0.5 W /ft2 0.7 W/ft2 Street frontage for vehicle sales lots in addition to "open area allowance No Allowance 10 W /linear foot 10 W /linear foot 30 W/linear foot Non- Tradable Surfaces° Building Facades No Allowance 0.1 W /ft2 for each illuminated wall or surfaces 0.15 W /ft2 for each illuminated wall or surface6 0.2 W /ft2 for each illuminated wall or surface' Automated teller machines and night depositories 270 W per locations 270 W per locations 270 W per locations 270 W per locations Entrances and gatehouse inspection stations at guarded facilities 0.75 W /ft2 of covered & uncovered area Loading areas for law enforcement, fire, ambulance and other emergency service vehicles 0.5 W/ft2 of covered & uncovered area Material handling and associated storage No Allowance No Allowance No Allowance 0.5 W /ft2 Drive -up Windows & Doors 400W per drive- through Parking near 24 -hour retail entrances 800 W per main entry FOOTNOTES FOR TABLE 15 -2B: 1. Base site allowance may be used in tradable or nontradable surfaces. 2. Lighting power densities for uncovered parking areas, building grounds, building entrances and exits, canopies and overhangs and outdoor sales areas may be traded. 3. Including vehicle sales lots. 4. Lighting power density calculations for the following applications can be used only for the specific application and cannot be traded between surfaces or with other exterior lighting. The following allowances are in addition to any allowance otherwise permitted in the "Tradable Surfaces" section of this table. 5. May alternately use 2.5 watts per linear foot for each wall or surface length. 6. May alternately use 3.75 watts per linear foot for each wall or surface length. 7. May alternately use 5 watts per linear foot for each wall or surface length. 8. An additional 90 watts is allowed per additional ATM location. 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting Power AIIowance Adjustments LTG -LPA 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 1640 Strander Blvd !Date 10/18/2011 Use this form if you are claiming any ceiling height adjustments for your Lighting Power Allowances for interior lighting. The Occupancy Description should agree with the "Use" listed on Code Table 15 -1. Identify the appropriate Ceiling Height Limit (9 feet, 12 feet or 20 feet) on which the adjustment is based. The Adjusted LPA is calculated from this number and from the Allowed Watts per ft2. Carry the Adjusted LPA to the corresponding "Allowed Watts per ft2" location on LTG -SUM. Adjusted Lighting Power Allowances (Interior) Location (floor plan /room #) Occupancy Description Allowed Watts per ft2** Ceiling Height for this room Ceiling Height limit for this exception** Adjusted LPA Watts per ft2 Lobby/Waiting 0.91 9.5 feet 9 feet 0.92 Welcome Center 0.91 9.5 feet 9 feet 0.92 Open Office /Hall 0.91 9.5 feet 9 feet 0.92 Closed Offices 0.91 9.5 feet 9 feet 0.92 Conf. 1.10 9.5 feet 9 feet 1.11 Mail /Copy 0.91 9.5 feet 9 feet 0.92 Storage 0.91 9.5 feet 9 feet 0.92 Break Rm. 0.91 9.5 feet 9 feet 0.92 Toilet - Mens 0.91 9.5 feet 9 feet 0.92 Toilet - Women 0.91 9.5 feet 9 feet 0.92 Hallway 0.91 9.5 feet 9 feet 0.92 " From Table 15-1 based on exceptions listed in footnotes 2009 Washington State Energy Code Compliance Form for Nonresidential and Multifamily Residential Lighting, Motor, 2009 Washington State Energy and Transformer Permit Plans Checklist LTG -CHK Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 640 strands= Blvd IDate 10/18/2011 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2009 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section 1513) N.A. 1513.1 Local controUaccess Schedule with type, indicate locations Yes 1513.2 Area controls Maximum limit per switch No 1513.3 Daylight zone control Schedule with type and features, indicate locations No vertical glazing Indicate vertical glazing on plans N.A. overhead glazing Indicate overhead glazing on plans No 1513.4 Display /exhib /special Indicate separate controls N.A. 1513.5 Exterior shut -off Schedule with type and features, indicate location N.A. (a) timer w /backup Indicate location N.A. (b) photocell. Indicate location N.A. 1513.6 Inter. auto shut -off Indicate location Yes 1513.6.1 (a) occup. sensors Schedule with type and locations No 1513.6.2 (b) auto. switches Schedule with type and features (back -up, override capability); Indicate size of zone on plans No 1513.7 HoteUmotel controls Indicate location of room master controls No 1513.8 Commissioning Indicate requirements for lighting controls commissioning EXIT SIGNS (Section 1514) Yes I 1514 IMax. watts 'Indicate watts for each exit sign I I LIGHTING POWER ALLOWANCE (Section 1530 -1532) Yes 1531 Interior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture N.A. 1532 Exterior Lighting Summary Form Completed and attached. Schedule with fixture types, lamps, ballasts, watts per fixture MOTORS (Section 1511) N.A. I 1511 IElec motor efficiency IMECH -MOT or Equipment Schedule with hp, rpm, efficiency I I TRANSFORMERS (Section 1540) N.A. I 1540 (Transformers 'Indicate size and efficiency I I If "no" is circled for any question, provide explanation: n Department of Community Development Jack Pace, Director • City of Tukwila Jim Haggerton, Mayor November 15, 2011 Chuck Lindberg 12920 SE 95 Way Newcastle, WA 98056 RE: Correction Letter #1 Development Permit Application Number D11 -343 US Coast Guard Recruiting — 640 Strander BI Dear Mr. Lindberg, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire, Planning and Public Works Departments have no comments. Building Department: Allen Johannessen at 206 433 -7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at (206) 431 -3670. Sincerely, Jennifer Mrshall Pe 't Technician e c 1 File o. DI1 -343 W:\Pennit Center\Correction Letters\2011\D11 -343 Correction Letter #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Project Name: U S Coast Guard Recruiting Permit #: D11 -343 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. The clearance for the toilet and sink do not meet accessibility code. Clearance around a water closet shall be 60 inches minimum, measured perpendicular from the sidewall, and 56 inches minimum, measured perpendicular from the rear wall. Required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, paper dispensers, sanitary napkin receptacles, coat hooks, shelves, accessible routes, clear floor space at other fixtures and the turning space. No other fixtures or obstructions shall be within the required water closet clearance. Revise floor plan for the bathroom to meet current 2003 ANSI. (ANSI 604.3.1 & 604.3.2 2. Show occupant calculation with the total number of occupants for the tenant on the plan. 3. Provide a detail to show the top of wall partitions seismically braced where necessary to the structure above. Specify fasteners and bracing. Should there be questions concerning the above requirements, contact the Building Division at 206- 431 -3670. No further comments at this time. HERMIT COORD CORY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -343 DATE: 11 /30/11_ PROJECT NAME: US COAST GUARD RECRUITING SITE ADDRESS: 640 STRANDER BL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued EPARTMENTS: BuTding (vision Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 12 /01 /11 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12 /29 /11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 HERMIT COM COP* PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: D11 -343 DATE: 10/19/11 PROJECT NAME: U S COAST GUARD RECRUITING SITE ADDRESS: 640 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPAR ,MENTS: 41:1 ing 'vision Wtk ublic Works Fire Prevention Structural Ote—tc at- ire Planning Division L��J Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete [) Comments: Incomplete DUE DATE: 10/25/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 11 /22 /11 Not Approved (attach comments) ly1 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg] Fire ❑ Ping ❑ PW ❑ Staff Initials: JV�. Documents /routing slip.doc 2 -28 -02 City of Tukwila Department of Community Development P6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206431-3665 Web site: htip://www.d.tulcwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 /�i] /ii Plan Check/Permit Number: D11-343 ❑ Response to Incomplete Letter # El Response to Correction Letter # 1_ ❑ Revision # after Permit is Issued • Revision requested by a City Building Inspector or Plans Examiner Project Name: US Coast Guard Recruiting Project Address: 640 Strander B1 Contact Person: Lk sG 41A/1,13197126'11 Summary of Revision: erg 7 A -1, p fl ,1v 4N l Hec Co4Uierv/T ?2 2 )/v/'�P i/rnii Im omL,4OUy.- CO41 U/ 11/ /i/)4vi 1 11) a v_pritei '/ =2` 4 Np -2. ,4- ) _ ,AA/G11EG Co A WNr ). c t' 0f1� ' - a APP GvGV` �V�GL 1�•� //�l GoG�7'/ 7� f�lZ • �,4 2 Nair )178V&7V-17 419Ae911fi brbr6s7likl 1Q4D44 1XXAWWI% V PL */At.? To 1 tp' lb 70 PLAN c / 40/1/1M air# 0 _0217x47 J7119 //1�/4 - ,4N�? 2/A.3 7D " NDi2/ w tit bT eel0 Sheet Number(s): A- I , A `'_2 V` A fiawboAe. "Cloud" or highlight all areas of revision including date of revision t'CA NOV 3 01011 Palma- ceotrEFI Phone Number: Received at the City of Tukwila Permit Center by Entered in Permits Plus on _it I ;11 II \applications \forms= applications on line\revision submittal Contractors or Tradespeople P.er Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name ENRICHED DESIGNS INC UBI No. 601070096 Phone 4252555467 Status Active Address 12920 Se 95Th Way License No. ENRICDI12809 Suite /Apt. License Type Construction Contractor City Newcastle Effective Date 9/29/1988 State WA Expiration Date 7/3/2013 Zip 98056 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date LINDBERG, CHARLES C President 06/15/2011 Amount LINGBERG, PENNY J President 09/29/1988 06/15/2011 YANTZER - TRISTA, KAREN Secretary 09/29/1988 06/15/2011 LINDBERG, NIKKI L Secretary 01/01/1980 06/15/2011 LINDBERG, CHARLES C Vice President 09/29/1988 06/15/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 TRAVELERS CAS & SURETY CO 103490911 07/01/2005 Until Cancelled $12,000.00 06/02/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 14 MAXUM INDEMNITY CO BDG0059813 02/08/2011 02/08/2012 $1,000,000.00 01/03/2011 13 MAXUM INDEMNITY CO BDG00059812 02/08/2007 02/08/2011 $1,000,000.00 01/06/2010 12 MAXUM INDEMNITY COMPANY BDG000598102 02/08/2005 02/08/2007 $1,000,000.00 01/11/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 12/05/2011 PROJECT GENERAL NOTES: 1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE BUILDING AND SITE WHILE THE JOB IS IN PROGRESS AND UNTIL THE WORK IS COMPLETED. 2. THE CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE THE SAFETY OF THE OCCUPANTS AND WORKERS AT ALL TIMES DURING THE COURSE OF THIS PROJECT. 3. ALL OPERATIONS CONDUCTED ON THE PREMISES SHALL NOT BE OBJECTIONABLE BEYOND THE PROPERTY BOUNDARY LINES BY REASON OF NOISE, STEAM, ODOR, FUMES, GASSES, SMOKE, VIBRATION, HAZARDOUS CONDITIONS OR OTHER SUCH CAUSES. 4. THE CONTRACTOR SHALL SECURE ALL SUCH INSPECTIONS AND FINAL APPROVALS FROM THE FIRE DEPARTMENT PRIOR TO OCCUPANCY. 5. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. COMMENCEMENT OF THE WORK CONSITUTES ACCEPTANCE OF EXISTING CONDITIONS AS ADEQUATE FOR THE PROPER COMPLETION OF THE WORK DETAILED HEREIN. 6. EXISTING DETAILS, ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE'CONTRACTOR PRIOR TO COMMENCEMENT OF WORK. IF CONDITIONS OR DETAILS DIFFER FROM THOSE SHOWN ON THE DRAWINGS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY SO THAT APPROPRIATE MODIFICATIONS CAN BE MADE BEFORE PROCEEDING. 7. THERE SHALL BE NO DEVIATIONS FROM THE CONTRACT DOCUMENTS WITHOUT THE ARCHITECT'S WRITTEN APPROVAL THEREOF. THE CONTRACTOR AGREES TO DEFEND, INDEMNIFY AND HOLD URBAN SOLUTIONS STUDIO, LLC AND THE ARCHITECT HARMLESS FOR ANY CLAIMS ARISING AS A RESULT OF UNAPPROVED CHANGES. 8. THE APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY ANY WORKMAN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME INFORMATION. THE CONTRACTOR SHALL ALSO MAINTAIN IN GOOD CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES, WHICH ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. 9. SEE STRUCTRUAL NOTES REGARDING LUMBER GRADES, NAILING, MISCELLANEOUS STRUCTURAL STEEL, GROUTING AND ATTACHMENTS. 10. DO NOT SCALE DRAWINGS - WRITTEN DIMENSIONS GOVERN. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IMMEDIATELY OF ANY AND ALL DISCREPANCIES. 11. ALL DIMENSIONS ARE TO THE CENTERLINE OF COLUMN, FACE OF STUD, CENTERLINE OF STUD OR FACE OF CMU - UNLESS OTHERWISE NOTED. 12. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, THE DETAILS SHALL BE THE SAME FOR OTHER SIMILAR WORK. 13. ALL WORK SHALL BE COMPLETED IN ACCORDANCE WITH THE MANUFACTURER'S LATEST RECOMMENDATIONS OR WRITTEN DIRECTIONS. 14. FIRE EXTINGUISHERS: VERIFY REQUIREMENTS AND LOCATION WITH FIRE MARSHALL. FIRE EXTINGUISHER LOCATIONS SHALL NOT BE BLOCKED OR HIDDEN BY PRODUCT DISPLAYS, DECOR FIXTURES OR ANY SUCH SIMILAR MATERIALS. 15. EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 16. EXIT DOORS, EXIT LIGHTS AND FIRE EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED OR OBSTRUCTED BY ANY DECORATIVE MATERIAL, DECOR OR FURNISHINGS. 17. FINISH FLOOR, TOP OF CONCRETE SLAB, DATUM = +0.00'. 18: ALL WOOD MEMBERS IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. 19. REFLECTED CEILING PLANS ARE FOR THE GENERAL INFORMATION OF THE CONTRACTOR. EXACT LOCATIONS OF LIGHTING FIXTURES AND CEILING MATERIALS SHOULD BE CONFIRMED PRIOR TO INSTALLATION. 20. PROVIDE SEISMIC BRACING AT ALL SUSPENDED ACOUSTICAL CEILING AREAS @ 12' O.C. IN BOTH DIRECTIONS. 21. THE CONTRACTOR SHALL VERIFY ALL WINDOW AND DOOR ROUGH OPENING REQUIREMENTS WITH DOOR AND WINDOW MANUFACTURERS PRIOR TO INSTALLATION. 22. EXTERIOR JOINTS AROUND WINDOWS AND DOOR FRAMES, OPENINGS BETWEEN WALLS AND FOUNDATION, BETWEEN WALLS AND ROOF AND OPENINGS AT PENETRATIONS OF UTILITY SERVICES THROUGH WALLS, FLOORS AND DOORS, AND ALL OTHER SUCH OPENINGS IN THE BUILDING ENVELOPE SHALL BE SEALED, CAULKED, GASKETED OR WEATHER- STRIPPED TO LIMIT AIR LEAKAGE AND PROHIBIT WATER PENETRATION. 23. ALL TEARS AND JOINTS IN BATT INSULATION TO BE SEALED WITH MANUFACTURER - APPROVED METHODS. 24. PLUMBING, ELECTRICAL AND HVAC SYSTEMS ARE BIDDER - DESIGNED AND COVERED UNDER SEPARATE PERMIT. CONTRACTOR SHALL SUBMIT BIDDER - DESIGN DRAWINGS TO ARCHITECT FOR REVIEW PRIOR TO FABRICATION AND INSTALLATION. TENANT SPECIFIC NOTES (CONTINUED) : 7. CAN DISTRIBUTION: CAN DISTRIBUTION PER DRAWING 8. RESTROOM EQUIPMENT: REFER TO DRAWINGS FOR ADA COMPLIANCE UNISEX RESTROOMS TO HAVE THE FOLLOWING FIXTURES - LIQUID SOAP DISPENSER, MIRROR ABOVE BASIN, SHELF ABOVE BASIN, TOILET PAPER DISPENSER, PAPER TOWEL DISPENSER, WASTE RECEPTACLE, 3 SHELF STORAGE CABINET MOUNTED 2' -0 " +/- ABOVE TOILET, COAT HOOK ON INSIDE SIDE OF DOOR, UNISEX RESTROOM SIGNAGE OF OUTSIDE OF DOOR 9. INTERIOR WINDOWS: INTERIOR WINDOWS TO BE EQUIPPED WITH VERTICAL BLINDS WITH WHITE OR OFF -WHITE METAL OR VINYL SLATS, OPERABLE FROM OFFICE SIDE SITE DATA: PROJECT ADDRESS: 644 STRANDER BLVD TUKWILA WA 98188 CURRENT ZONING: TUC (CITY OF TUKWILA) PARCEL NUMBER: 000580 -0037 PROJECT TEAM: BUILDING OWNER: BC PARTNERS.LLC C/O MK PROPERTY SERVICES SNOQUALMIE WA 98065 425 - 888 -2993 TENANT: UNITED STATES COAST GUARD ARCHITECTURAL: urban solutions studio. Iic 1555 UNION AVE NE (66) RENTON WA 98059 206 - 734 -4422 CONTACT: WARWICK ASHLEY GENERAL CONTRACTOR: EDI 12920 S.E. 95th Way NEWCASTLE WA 98056 425 - 255 -5467 CONTACT: CHUCK LINDBERG WORK DESCRIPTION: INTERIOR TENANT IMPROVMENT TO EXISTING VACANT 2,500 S.F. (WORK AREA) STOREFRONT SPACE. NO EXTERIOR MODIFICATIONS TO THE BUILDING SHELL ARE PLANNED UNDER THIS SUBMITTAL. SIGN PERMIT WILL BE UNDER A SEPARATE SUBMITTAL. OCCUPANCY: GROUP B TENANT SPECIFIC NOTES: 1. COMPLY WITH LOCAL CONSTRUCTION CODES AND STANDARDS OF CITY OF TUKWILA 2. PROVIDE ADA COMPLIANT RESTROOM 3. ELECTRICAL DISTRIBUTION: ADD DUPLEX RECEPTACLES AS REQUIRED FOR EACH WALL OF PRIVATE OFFICES AND CONFERENCE ROOM ADD MINIMUM OF TWO DUPLEX RECEPTACLES NO FURTHER THAN FOUR FEET APART, AS REQUIRED, AT COUNTERS AND ADMINISTRATIVE AREAS ADD DUPLEX RECEPTACLE AS REQUIRED IN STORAGE AREA TO POWER TENANT'S TELEPHONE EQUIPMENT ADD DUPLEX RECEPTACLES AS REQUIRED TO APPROXIMATE EIGHT FOOT INTERVALS BETWEEN RECEPTACLES AT OFFICES, COMMON AREAS AND FOYERS ADD TWO DUPLEX RECEPTACLES AT KITCHEN COUNTER ADD DUPLEX RECEPTACLE AT CABINET AREA PROVIDED FOR UNDER COUNTER REFRIGERATOR 4. LIGHTING DISTRIBUTION: EXISTING FLUORESCENT LIGHTING TROFFERS TO BE RELOCATED TO PROVIDE 50 FOOT CANDLES OF ILLUMINATION AT WORK SURFACES AND 30 FOOT CANDLES AMBIENT (MEASURED AT 30" ABOVE FINISH FLOOR, TYPICAL) 5. CONTROLS DISTRIBUTION: CONTROLS FOR LIGHTING, HVAC, ALARMS OR SIMILAR, TO BE LOCATED NO MORE THAN 54" ABOVE FINISH FLOOR, ADJACENT TO ENTRY WAYS, AND DOORS, TYPICAL 6. TELEPHONE DISTRIBUTION: TELEPHONE RECEPTACLES AND PULL WIRES TO BE PLACED ADJACENT TO DUPLEX RECEPTACLES IN OFFICES, CONFERENCE ROOM AND ADMINISTRATIVE AREAS EXISTING TELEPHONE TERMINUS TO BE REUSED (REFERENCE DRAWING) OCCUPANCY LOAD CALCULATION: IBC GROUP B = 1 OCCUPANT /100 S.F. X 2,500 NET S.F. = 25 OCCUPANTS CONSTRUCTIO V -B PARKING PROVIDED: NO CHANGE VALUATION OF WORK: $ 79,170.00 LEGAL DESCRIPTION: MEADER HENRY D -C #46 LOT 1 OF CITY OF TUKWILA SHORT PLAT NO 84 -31 -SS RECORDING NO 8501030748 SD SHORT PLAT DAF - POR NW 1/4 OF SEC 25 -23 -04 -BAAP ON WLY RNV LN OF WEST VALLEY HWY SR 181 AT A PT WCH BEARS S 81 -07 -31 W 50 FT FR C/L THOF AT HWY ENGR STA 160 +00 TH FR SD POB ALG SD WLY R/W LN S 12 -18 -30 E 250.45 FT TAP WCH BEARS S 81 -07 -31 W 35 FT FR C/L AT HWY ENGR STA 162 +50 TH S 05 -15 -06 E 112.35 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO RGT RAD 50 FT & A C/A OF 86 -22 -37 ARC LENGTH 75.38 FT TAP ON NLY R/W LN OF STRANDER BLVD TH ALG SD NLY R/W LN TANGENT TO PRECEDING CURVE S 81 -07 -31 W 28.58 FT TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT RAD 700 FT & C/A OF 19 -33 -22 ARC LENGTH 238.92 FT TH TANGENT TO PRECEDING CURVE S 61 -34 -09 W TO INTSN OF SD NLY RNV LN OF STRANDER BLVD WITH ELY BANK OF GREEN RIVER TH NLY ALG SD ELY BANK TO INTSN WITH SLY LN OF BOW LAKE P/L R/W 30 FT WIDE TH ALG SD SLY LNS S 87 -12 -48 E 194.01 FT TAP ON WLY RNV LN OF SD WEST VALLEY HWY TH ALG SD WLY R/W LN S 08 -52 -29 E 165.06 FT TO POB SHEET INDEX: A -1 COVER SHEET A -2 EXISTING FLOOR PLAN PROPOSED FLOOR PLAN DOOR SCHEDULE DETAILS A -3 REFLECTED CEILING PLAN ROOM FINISH SCHEDULE DETAILS FX E COPY, Permit No 3 Ple.n review approval is subject to errors and om9sslone, °ai of construction documents does not authcri ".s ' .cr.i of adopt I�;;: .,:,.�;;4r�i"i :�, any code or ordinarco. Receipt c Li.iprovE4 Fig c Cc p . ' • ; : ,�� an _y ons is aC%nowledg�� By7 k Date: /02- City Of Tiikwila BUILDING DIVISION NTERURBAN P` TO AVES r,�Q�P`" HWY167 TO S -90 TU W I LA SOUTHCENTER BLVD TUKWILA PARKWAY cn w cc a w O 0 z STRANDE BLVD w cc w w O 0 z GREEN RIVER RENTON VICINITY MAP _ /SCALE: 1" - 1000' -0' SCALE: 1 " - 1000' -0' ROPERTY LINES' ITE 500' 1000' • • • • REVISIONS "o changes shall bra made to the scope a1 work without prior approval of Tukwila Building Division. 7.: Revisions will require a new plan submittal d may include additional plan review fees. NORTH W a S " '~ ARVTE PERMIT REQUIRED FOR: liPIVIOchanical I 1actrical iiMumbing �a Piping C "7 of Tukwila 1..:W 1N (1 DIVISION STRANDER BLVD COFHECjION pi I TFld SITE PLAN - 640 STRANDER BLVD, TUKWILA WA SCALE: 1" = 40' -0" REVIEWED FOR CODE COMPLIANCE APPROVED DEC 01 2011 Ar VWk City of Tukwila BUILDING DIVISION RECEIVED LA NOV ?02011 PERMIT CENTER MOW 0 20' 40' • • • • NORTH Vf 0 0 roc L N a) o co ▪ 0 • LU • LU H 2 w z 0 "a z 0 0 0 1- z 0 0 N z INTERIOR TENANT IMPROVEMENT W w v7 IADATE REMARKS BY 1 10/18/11 PERMIT SUBMITTAL - I2 11/30/11 CITY PLAN CHECK COMMENTS 1 1 1 PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING DRAWN BY: SM /GB CHECKED BY: WA JOB #: PHASE: DATE: 10/18/11 SHEET #: A -1 LSHEET 1 OF 3 J -J EXIST. DEMISING WALL TO REMAIN T ILET (E REMOVE EXISTING LAV AND OUTLET REMOVE AND RETAIN EXIST. DOOR AND FRAME DEMO EXIST. WALL TO UNDERSIDE OF EXIST. GWB CEILING 220 G.C. TO REMOVE ALL EXISTING CARPETING DOOR SCHEDULE DEMOLITION PLAN SCALE: 3/16" = 1' -0" # DOOR FRAME FINISH NEW/ EXIST'G. HARDWARE NOTES SIZE MAT'L. MAT'L. 1 DBL. 3/0 X 7/0 STOREFRONT ALUM. ALUM. FACT. (E) EXIST'G. EXIST.0 ? 2 3/0 X 7/0 FLUSH STEEL STEEL PAINT (E) EXIST'G. EXIST. 3 3/0 X 7/0 FLUSH SC WD. STAIN (E) EXIST'G. EXIST. 4 3/0 X 7/0 FLUSH SC WD. STAIN (E) EXIST'G. EXIST. 5 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 6 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 1 7 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 2 8 3/0 X 7/0 FLUSH SC WD. WOOD STAIN NEW GROUP 3 9 HARDWARE GROUPS: NOTES KEY: RELEASE LOCKS PER USCG REQUIREMENTS GROUP 1 GROUP 30 INSTALL ELECTRIC 1 1/2 PAIR PRIVACY SILENCERS GROUP 2 BUTTS 1 1/2 PAIR BUTTS LATCHSET PASSAGE LATCHSET SILENCERS DEADBOLT BUTTS LATCHSET 1 1/2 PAIR PASSAGE SILENCERS 5' 10' NORTH POWER /COMM. KEY NEW CAT5 CABLE BOX @ 12" A.F.F. - NEW DUPLEX OUTLET @ 12" A.F.F. - EXIST. DUPLEX OUTLET TO REMAIN ALT. VOLTAGE 11' -4 "(E) 55' -11" +/- (E) RECRUITER # RECRUITER # RECRUITER RECRUITER #5 ::1::1::1:111:1:21::1:11:J e: :J::H:11:e1l:e::e::M se:u::e::e,:era::e::ra TYP. @ CHAIR RAIL 1 iii'/ r. II� E I i I _ J MAIL /COPY / IL % III ;. /��� / / //, ,.�W / / / / / //' Y / / / / / / / / / / / / / / / / / / /,, 4:J.:.;7 ;49Z :/ ZJZ :Z.::9:-.'�;1eZ. Vi II„ RECRUITER #7 i ,�1� C I N � / � 111 • RECRUITER #6 OFFICE (RIC) '4 N 111 ✓ L 9. III „ n N c ►! N As% III OFFICE (XPO) WAITING AREA`J LOBBY O 1 O) CENTER 14'- 1134 "(E) r 1 \FLOOR PLAN 91 -9" ul 4w 41 -6" ` 10' -1" 91 -4" 10' -2" +1- =a= EXIST. FLOOR OUTLET TO REMAIN E NOTES: 1. ALL EXISTING OUTLETS ARE ASSUMED TO BE 110V, UNLESS OTHERWISE NOTED. 2. ELECTRICIAN TO VERIFY ALL CLEAN POWER REQUIREMENTS WITH TENANT PRIOR TO COMPLETION OF WORK. SCALE: 3/16" = 1' -0" 1 x 6 HDF CAP (PAINTED) +78" ABOVE FINISH FLR. 5/8 x 3 HDF TRIM (PAINTED) NOTE: LOW -WALL ANCHORS TO BE MODEL 350P200 -68 AS MANUFACTURED BY STEELER AND STEELER INC. 0 5' 10' WALL CAP DETAIL _ / SCALE: N.T.S. +39" ABOVE FINISH FLR. 5/8 x 5 CHAIR RAIL (PAINTED) WALL TYPE (PER PLAN) CHAIR RAIL DETAIL SCALE: N.T.S. NORTH WALL TYPE KEY B E WALL TYPE (78" TALL): > 5/8" GWB > 3 5/8" MTL STUDS @ 16" 0.C. > 5/8" GWB WALL TYPE (42" TALL): > 5/8" GWB > 3 5/8" MTL STUDS @ 16" O.C. > 5/8" GWB * *CHAIR RAIL (TYP. WHERE SHOWN) WALL TYPE (FULL HGT. TO T -BAR): > 5/8" GWB >3 5/8" MTL STUDS @ 16" O.C. > 5/8" GWB ** ACOUST. INSUL. (TYP. WHERE SHOWN) WALL TYPE > EXISTING FRAMED WALL TO REMAIN 1 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 1 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TIIKWILA NOV 3 0 2011 PERMIT CENTER 0 • eee� 3 sia 0 0 mm N o co z 0 w W z CD y • z — O Z — In o to d as N (1) J I—z�a Z Q 1- H V�UZO X00 FaF- : W m < O OCnj Q m =ow O w> Ou_ <zww N 0O. 0 Z EaU=wOt~N�� �¢( 0 aa� w O. (1)) j• ZnT m= z • "a >-° J o°� 0 0 co — • atat! Li) ZZ zu- W aw p0EUQ O <w� N y a U z c: �Z °ice g ~ac 2aouvi ©ao INTERIOR TENANT IMPROVEMENT oC 0 w w J c LL REMARKS BY I PERMIT SUBMITTAL CITY PLAN CHECK COMMENTS 1 1 1 I PLEASE CONSIDER THE ENVIRONMENT I BEFORE PRINTING THIS DRAWING 1 I 1 ? , 1 1 1 DRAWN BY: SM /GB CHECKED BY: WA JOB #: PHASE: DATE: 10/18/11 SHEET #: A -2 LSHEET 2 OF 3 J ROOM FINISH SCHEDULE ROOM WALLS FLOOR CEILING , COVE BASE NOTES RECRUITER # 1 PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Partial Ht Wall c/w 1x Cap RECRUITER # 2 PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Partial Ht Wall c/w 1x Cap RECRUITER # 3 PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Partial Ht Wall c/w 1x Cap RECRUITER # 4 PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Partial Ht Wall c/w 1x Cap RECRUITER # 5 PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Partial Ht Wall c/w 1x Cap, Exist. Blinds RECRUITER # 6 PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Exist. Blinds RECRUITER # 7 PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES LOBBY PAINT - SW6246 & SW6967 CARPET ACOUSTIC TILE (E) YES Pony Wall c/w Cap , Accent CIr, Exist. Blinds WAITING AREA PAINT - SW6246 & SW6967 CARPET ACOUSTIC TILE (E) YES Pony Wall c/w Cap , Accent Color WELCOME CTR PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Bulkhead wall above counter, Exist. Blinds OFFICE (RIC) PAINT - SW6246 CARPET ACOUSTIC TILE (E) ' YES Bottom of relite 42" AFF, Vert. Blinds OFFICE (XPO) PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Bottom of relite 42" AFF, Vert. Blinds CONFERENCE PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES Exist. Blinds MAIUCOPY PAINT - SW6246 CARPET ACOUSTIC TILE (E) YES BREAKROOM PAINT - SW6246 VCT (12 "X12 ") ACOUSTIC TILE (E) YES STORAGE PAINT - SW6246 VCT (12 "X12 ") ACOUSTIC TILE (E) YES Exist. Blinds WC (NORTH) PAINT- SW6246/ Ceramic Tile VCT (12 "X12 ") GWB (E) YES 12 "X12" Ceramic Tile to 4' -0" AFF WC (SOUTH) PAINT- SW6246/ Ceramic Tile VCT (12 "X12 ") GWB (E) YES 12 "X12" Ceramic Tile to 4' -0" AFF HALLWAYS PAINT - SW6246 & SW6967 CARPET ACOUSTIC TILE (E) YES 1x Chair Rail /Top 39" AFF Typ. Coronet Commercial Passport II 26/26 Color - Cabaret 3405 EXIST. ROOF FRAMING ABOVE MIN. 4X4 BRIDGE BLOCKING BETWEEN EXIST. FRAMING AS OCCURS BRACE TOP PLATE TO EXIST. STRUCTURE ABOVE @ 48" O.C. (ALTERNATE DIRECTIONS /SIDES AS SHOWN) EXIST. T -BAR CEILING (PER PLAN) WALL TYPE (PER PLAN) EXIST. VENT FANS TO REMAIN (TYP.) GC TO REPLACE EXIST. LIGHT FIXTURES OVER SINK WITH NEW UNITS (1 - 46W FLUOR. LAMP EACH - TYP. 2 LOC.) EXISTING GWB CEILING AT TOILET ROOM TO REMAIN - REPAIR AND REPAINT AS REQ'D. (TYP.) EXISTING 2' X 4' TROFFER FIXTURES RELOCATED IN EXISTING CEILING GRID AS SHOWN - CHANGE TO (4) T -8 TUBES (TYP.) TOTAL WATTAGE /FIXTURE: 96 WATTS MAX. E/R E/R E/R E/R EXIST. T -BAR CEIL NG @9' -b1 /2 "A.F E/R .F. TO REMAI EXIT E/R E/R E/R INTERNALLY ILLUMINA —ED E/R E/R E E/R EXIT SIGNS(TYP.) E/R N (TYP.) E/R E/R ALL NEW FULL - HEIGHT WALLS TO BE ED TO UNDERSIDE OF EXIST. T -BAR CEILING (UNLESS NOTED OTHERWISE) - BRACE TOP PLATE TO EXIST. STRUCTURE PER CODE (TYP.) L3 1/2" ALL - THREAD @ 48" O.C. TO STRUCT. AS REQ'D. TO SUPPORT B LKHEAD WALLS @ WELCOME CENTER + 91-5 1/2" A.F.F. (EXIST.) REFLECTED CEILING PLAN CAN CONNECTION FOR 0 DISPLAY PER TENANT RECESSED CAN FIXTURES W/ (1 EACH) 60W FLUOR. LAMPS - 3 LOCATIONS IN EXISTING CEILING GRID AS SHOWN (TYP.) NORTH SCALE: 3/16" = 1' -0" EXIST. GWB NEW 12" (2) #6 PANHEAD SCREWS AT EACH DIAG. BRACE CONNECTION - TOP & BOTTOM (TYP.) WALL BRACE D SCALE: 1 1/2" = 1' -0" 10%" // 48" SAFETY GLASS CV d' OFFICE RE-LITE ELEV. SCALE: 3/16" = 1' -0" REPL EXIST. TP EXIST. TOILET TO REMAIN (TYP.) RTH TOILET RM. ELEV. SCALE: 3/16" -1' -0" REPLACE EXIST. LIGHT FIXTURE (TYP.) NEW 18 X 30 WALL MIRROR AND SHELF (TYP.) EXIST. LAV SINK TO REMAIN (TYP.) SOUTH TOILET RM. ELEV. SCALE: 3/16" -1' -0" 0 5' 10' REVIEWED FOR CODE COMPLIANCE APPROVED DEC 01 2011 City of Tukwila BUILDING DIVISION b 3 RECEIVtu CITY OF TUKWILA NOV 3 U 2011 PERMIT CENTER 0 V'f 0 0 iA N cn d co 01 a)� m • O • z LLJ to W z a) LLJ C a '- O a in WWW.URBANSOLUTIONSSTUDIO.COM co co UJ U° CZ Q � g O~ p r f1 v, z H � Q m O oC • w (, z � U W o INTERIOR TENANT IMPROVEMENT 0 z_ J_ uJ U 0 W 0 W uJ q w W J IADATE REMARKS BY 1 1 10/18/11 PERMIT SUBMITTAL - 2 11/30/11 CITY PLAN CHECK COMMENTS 1 1 4 1 1 PLEASE CONSIDER THE ENVIRONMENT BEFORE PRINTING THIS DRAWING DRAWN BY: SM /GB CHECKED BY: WA JOB #: PHASE: DATE: 10/18/11 SHEET #: A -3 LSHEET 3 OF 3 J