HomeMy WebLinkAboutPermit EL11-1060 - MACY'SMACY'S
500 SOUTHCENTER MALL
EL1 1 -1060
City olOI'ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 2623049086
Address: 500 SOUTHCENTER MALL TUKW
Project Name: MACY'S
ELECTRICAL PERMIT
Permit Number: EL11 -1060
Issue Date: 01/06/2012
Permit Expires On: 07/04/2012
Owner:
Name: FEDERATED DEPT STORES INC
Address: ATTN: TAX DEPARTMENT - SHF , 7 W 7TH ST
Contact Person:
Name: PAUL HANSON
Address: P 0 BOX 33524 , SEATTLE WA
Contractor:
Name: COCHRAN INC
Address: PO BOX 33524 , SEATTLE WA
Contractor License No: COCHRI *088JS
Phone: 206 - 604 -0993
Phone: 206 367 -1900
Expiration Date: 04/11/2012
DESCRIPTION OF WORK:
ADDITION OF (2) EXISTING LIGHTING PANELS TO AN EXISTING GENERATOR SOURCE.
Value of Electrical: NRES: $20,000.00
RES: $0.00
Fees Collected:
Type of Fire Protection: UNKNOWN National Electrical Code Edition:
Electrical service provided by: PUGET SOUND ENERGY
Permit Center Authorized Signature:
$545.63
2008
Date: 1— (vs-- (
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting
construction
Signature:
Print Name:
not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
of work. I am authorized to sign and obtain this electrical permit.
P Al) u -1 -1'6-N) s O YJ
Date: / G // Z
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: EL -4/10
EL11 -1060 Printed: 01 -06 -2012
41
PERMIT CONDITIONS
Permit No. EL11 -1060
* *ELECTRICAL **
1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector
at each work site.
2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector.
3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter
296 -46B WAC.
4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the
building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector.
5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation
of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that
presumes to grant this authority are therefore not valid.
6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where
approved plans have been issued, revisions to the plans and additional review may be required.
doc: EL -4/10
ELI 1-1060 Printed: 01 -06 -2012
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http.//www.ci.tukwila.wa.us
Electrical Permit No. t-L 11 (0 t(i 0
Project No.
(For office use only)
ELECTRICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *Please Print **
SITE LOCATION
King Co Assessor's Tax No.:
Site Address: 500 Southcenter Mall, Tukwila, WA 98188 Suite Number: N/A Floor: N/A
Tenant Name:
Macy's
Property Owners Name: MaCy'S
New Tenant: ❑ Yes ..No
Mailing Address: 3rd & Pine St.
Seattle
City
WA
State
98101
rip
CONTACT PERSON -Who do we contact when your permit is ready to be issued
Name: Paul Hanson
Mailing Address:
E -Mail Address:
P.O. Box 33524
Day Telephone:
Seattle
(206) 604 -0993
WA 98133
phanson @cochraninc.com
City State
Fax Number: (206) 368 -3197
Zip
ELECTRICAL CONTRACTOR INFORMATION
Company Name:
Mailing Address:
Contact Person:
Cochran, Inc.
P.O. Box 33524
Seattle, WA 98133
Barbara Trochmann
E -Mail Address:
btrochmann @cochraninc.com
Contractor Registration Number: COCHRI *088JS
City State
Day Telephone: (206) 923 -7655
Fax Number: (206) 368 -3197
Expiration Date: 04/11/2012
Lip
Valuation of Project (contractor's bid price): $ 20,000
Scope of Work (please provide detailed information): Addition of (2) existing lighting panels to an existing
generator source.
Y� . — •
—
Will service be altered? ® Yes ❑ No Adding more than 50 amps? ❑ Yes ® No
Type of use: Emergency lighting for existing retail space.
Type of work:
❑ New ® Addition
❑ Low Voltage ❑ Generator
Property Served by:
® Puget Sound Energy
❑ Seattle City Light
❑ Service Change
❑ Fire Alarm
11 \Applications \Forms - Applications On LineQ010 Applications \1 -2010 - Electrical Permit Application doc
bb
Page 1 of 2
❑ Remodel ❑ Tenant Improvement
❑ Telecommunication ❑ Temporary Service
RESIDENTIAL
NEW RESIDENTIAL SER \'ICE
❑ New single family dwellings
(including an attached garage)
❑ Garages, pools, spas and outbuildings
❑ Low voltage systems
(alarm. furnace thermostat)
$1 52.85
$81.90 ea
$59.85 ea
RESIDENTIAL REMODEL AND SERVICE CHANGES
❑ Service change or alteration $81.90
(no added /altered circuits)
❑ Service change with added /altered circuits $81.90
number of added circuits $11.55 ea
❑ Circuits added /altered without service change $54.60
(up to 5 circuits)
❑ Circuits added /altered without service change $54.60
(6 or more circuits) $7.65 ea
❑ Meter /mast repair $68.25
❑ Low voltage systems $59.85
(alarm. furnace thermostat)
MULTI- FAMILY AND COMMERCIAL
Fees are based on the valuation of the electrical contract.
MISCELLANEOUS FEES
❑ Temporary service (residential) $63.00
❑ Temporary service (generator) $78.75
❑ Manufactured /mobile home service $84.00
(excluding garage or outbuilding)
❑ Carnivals $78.75
Number of concessions $ 1 0.50 ea
PERMIT APPLICATION NOTES -
Value of Construction — In all cases. a value of construction amount should be entered by the applicant. This figure will he reviewed and is subject
to possible re ision by the Permit Center to comply, with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall he requested in writing
and justifiable cause demonstrated.
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR TI -IIS PERMIT.
BUILDING OWNER 011 - LEC. IC L CONTRACTOR:
Signature:
Print Name: Barbara ochmann
Mailing Address: 12500 Aurora Ave N
Date: 11/21/2011
Day Telephone: (206) 923 -7655
Seattle
City
WA 98133
State
Zip
Date Application Accepted: 1 v...1 p,, iG Date Application Expires: 14 Staff Initials: VC
H \ApplIcatione \Forms - Applications On Li net2010 Applications \1 -2010 - Elecmcal Permit Application doc
hit
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 2623049086 Permit Number: EL1 1-1060
Address: 500 SOUTHCENTER MALL TUKW Status: APPROVED
Suite No: Applied Date: 11/28/2011
Applicant: MACY'S Issue Date:
Receipt No.: R12 -00039
Initials:
User ID:
Payee:
WER
1655
Payment Amount: $436.50
Payment Date: 01/06/2012 09:27 AM
Balance: $0.00
COCHRAN INC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 18649 436.50
Authorization No.
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
000.322.101.00.00 436.50
Total: $436.50
doc: Receiot -06 Printed: 01 -06 -2012
1 •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: / /www.TukwilaWA.gov
Parcel No.: 2623049086
Address: 500 SOUTHCENTER MALL TUKW
Suite No:
Applicant: MACY'S
RECEIPT
Permit Number: EL11 -1060
Status: PENDING
Applied Date: 11/28/2011
Issue Date:
Receipt No.: R11 -02567
Initials: WER
User ID: 1655
Payee:
COCHRAN INC
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Check 18642 109.13
Authorization No.
ACCOUNT ITEM LIST:
Description
Payment Amount: $109.13
Payment Date:
Balance:
03:26 PM
Account Code Current Pmts
ELECTRICAL PLAN - NONRES
000.345.832.00.00 109.13
Total: $109.13
doc: Receiot -06 Printed: 11 -28 -2011
INSPECTION.. RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 ., (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
64- ic)
Project: pikel r
Type of Inspection: 2(0
Address:
Date Called:
Special Instructions:
Date Wanted :. /p2.-
a r
P".
Requester: n
,6/14i
Phone No: Zoo 730 O�7 '
►i
pproved per applicable codes.
aCorrections required prior to approval.
COMMENTS:
6(Akicitoas Pvt.
Date:
0 3/0 2-
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
1
r•
•
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 K. (206) 431 -367
Permit Inspection Request Line (206) 431 -2451
611_1060
Project: 'i i � l
rt
Type of Inspection:
00
Address: 5 '
Date Called:
Special Instructions:
1.PRtu�
Date Wanted:.
7
a.
Requester:
Ill.
Phone No:
n DOT
Approved per applicable codes.
aCorrections required prior to approval.
COMMENTS:
1
rd( 3A2.-
Inspector: /7 7 N
Date: V3 0! ,■
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO.
Opa
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 ; d2- (206) 431 -3670
Permit Inspection Request Line (206) 431 -2451
Project: t�
Type of Inspection:
2 foO
Address: Sao
Date Called:
Special Instructions
6-“/
Date Wanted:.
a.
Requester:
Phone No:
LJApproved per applicable codes.
COMMENTS:
Corrections required prior to approval.
OK
- oxickciiit
e,1I'�t r6 L /h
, -- �►S
FlooVeNkrizivn4
Inspector:
'Date: 02/41 (L_
❑ REINSPECTION FEE REQUIRED! Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
•
•
•
INSPECTION RECORD
Retain a copy with permit W /0 JJ p 0
INSPECTION NO. ERMIT NO.
• CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 ig (206) 431 -36
Permit Inspection Request Line (206) 431 -2451
Project: �401 1 _
5
Type of Inspection:
Address: �� frft,
Date Called:
Special Instructions
I,. •
Date Wanted:.
3v
a.m.
P.m.
Requester:
Phone No:
JApproved per applicable codes.
DCorrections required prior to approval.
'COMMENTS:
6611,11.. liVscof‘)AID
Inspector
Date:
i 3o rZ
REINSPECTION FEE REQUIRED. prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
480Y/277v SERVICE SWITCHBOARD
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
❑ Electrical
genumbing
i 'Gas Piping
r‘',7 of Tukwila
DIVISION
UTILITY XFMR.
480Y/277v
(ROOF)
800A
MCC -1
800A
ATS
•
MCC -1A
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
1'\'"7".:: r oV'son3 will require a new plan submittal
c may ins °ude additional Wan review fees.
300kW/375kVA
600A---„G__ GENERATOR
(ROOF)
500A
rTh
— 70A
• FI• COPY
Pewit No., i— t – 10 (O t)
PInn rrview approval is subject to errors and omissterm
t, • : _5 f of oorstruction documents does not a;. hc= ze
ny a o ted code or ordinance. Rec .pt
o
Li.iprov • ci and conditions is acknowisdg;;d
By
Y
Date: t
City Of lbkwiia
BUILDING DIVISION
NEW CIRCUIT BREAKER TO BE INSTALLED IN SPARE MCCSTARTER/FEEDER DEVICE COMPARTMENT
1" (3) #4, (1) #8 GND
GENERAL NOTES
1. EQUIPMENT IS EXISTING AND IN PLACE IN THE PENTHOUSE OF THE MACY BUILDING UNLESS NOTED OTHERWISE.
2. ALL NEW WIRE IS COPPER.
3. REFER TO LOAD CALCULATIONS ON SEPARATE 8'A" X 11" WORK SHEET.
4. VERIFY EXISTING FEEDER SIZES: PROVIDE MINIMUM # 4 CU. EQUIPMENT GROUND CONDUCTOR.
5. VERIFY EXISTING GROUND ELECTRODE CONDUCTOR SIZE: PROVIDE MINIMUM #4 CU.
6. VERIFY EXISTING TRANSFORMER SECONDARY DISCONNECT SIZE: PROVIDE MAXIMUM 175A.
L I___,_i
EXISTING TRANSFORMER LOCATED IN BASEMENT
XFMR T -EM
45 kVA
Y 480.208Y/120v
175A
(MAX)
PANEL EM2
225A MLO
208Y/120v
10K AIC
(3R0 FLR)
PANEL EM1
225A MLO
208Y/120v
10K AIC
(BASEMENT)
EXISTING GROUND ELECTRODE CONDUCTOR (NOTE
EXISTING SECONDARY DISCONNECT (NOTE 6)
EXISTING FEEDER (NOTE 5) (TYP)
EL(H060
CORRECTION
LTR #_�_
coc ran
REVIEWED I-UK
COMPLIANCE WITH
NFPA70 - NEC
LI, C 2011
V WIC
City of Tukwila
BUILDING DIVISION
RECEIVED
DEC 08 2011
PERMIT CENTER
Partial Power One Line Diagram E -1
Drawn by: Martin A. Dilks, Cochran, Inc.
November 16, 2009, Revised: December 8, 2011
Generator System Modifications
Macy's — Southcenter Mall
500 Southcenter Mall, Tukwilla, WA 98188
Macy's Southcenter Emergency Generator
Existing Loads
MCC -1A
Fdr No HP FLA ( Note1) kVA
26 30 40 31.9
27 30 40 31.9
28 25 34 27.1
29 30 40 31.9
30 30 40 31.9
31 40 52 41.4
32 40 52 41.4
MCC -1A TOTAL 237.4
Amps @ 480v 3 -Ph =
MCC -1A -1
Fdr No HP FLA ( Note1) kVA
33 10 14 11.2
34 10 14 11.2
35 10 14 11.2
MCC -1A -1 TOTAL 33.5
Amps @ 480v 3 -Ph =
REVIEWED C� �R
COMPLIANCE WITH
NFPA 70 - NEC
285.6
40.3
TOTAL EXISTING GENERATOR LOAD = 270.9
Amps @ 480v 3 -Ph = 325.8
es; 1 G 2011
City of Tukwila
UILDING DIVISION
Added Load Amps (Note 2) kVA Demand
Lighting, Panels EM1 & EM2 29 24.1 30.1 kVA
TOTAL NEW GENERATOR DEMAND LOAD =
Amps @ 480v 3 -Ph =
Existing Generator Capacity = 375kVA
NEW MCC -1A -1 DEMAND LOAD =
Amps @ 480v 3 -Ph =
301.0 kVA
362.1 Amps
63.6 kVA
76.5 Amps
Notes
1. Full -Load current per NEC Table 430.250
2. Panels EM1 and EM2 feed existing 120v lighting loads. Loads were recorded by the Owner on the
primary side of an existing 480v- 208Y/120v step -down transformer while all circuits were fully loaded
(All lightis were turned on). The maximum phase load recorded on the 480v side was 29 amps.
RECEU V Er
NOV 28 2011
MATER
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
December 1, 2011
Paul Hanson
Cochran Inc
PO Box 33524
Seattle, WA 98133
RE: Correction Letter #1
Electrical Permit Application Number EL11 -1060
Macy's — 500 Southcenter Mall
Dear Mr. Hanson,
This letter is to inform you of corrections that must be addressed before your development permit can be
approved. All correction requests from each department must be addressed at the same time and
reflected on your drawings. I have enclosed comments from the Building Department.
Building Department: Jim Benner at 206 - 431 -3679 if you have questions regarding the
attached memo.
Please address the attached comments in an itemized format with applicable revised plans,
specifications, and /or other documentation. The City requires that two (2) sets of revised plans,
specifications and /or other documentation be resubmitted with the appropriate revision block.
In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every
resubmittal. I have enclosed one for your convenience. Corrections /revisions must be made in person
and will not be accepted through the mail or by a messenger service.
If you have any questions, please contact me at (206) 431 -3670.
Sincerely,
Bill Rambo
Permit Technician
encl
File No. ELI 1-1060
W:\Permit Center \Correction Letters\2011\EL11 -1060 Correction Letter #1.doc
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665
Tukwila Building Division
Jim Benner, Electrical Inspector
Building Division Review Memo
Date: Dec. 1, 2011
Project Name: Macy's
Permit #: EL11 -1060
Plan Review: Jim Benner, Electrical Inspector
The Building Division conducted a plan review on the subject permit application. Please address the
following comments in an itemized format with revised plans, specifications and /or other applicable
documentation.
(GENERAL NOTE)
PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size).
Please include One Line Diagram, Load Summary, and Panel Directories (where applicable)
1. Terminate transformer secondary conductors in a single overcurrent device set at 175A max on
supply side of junction point per Table 450.3 (B) Note 2.
2. Grounding electrode conductor to be #4 cu per 250.30 (A) (3).
3. Equipment bonding conductor from transformer secondary to first overcurrent device to be #4 cu per
250.30 (A) (2).
Should there be questions concerning the above requirements, contact the Building Division at 206 -431-
3670. No further comments at this time.
• -n •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL11 -1060 DATE: 12 -08 -11
PROJECT NAME: MACY'S
SITE ADDRESS: 500 SOUTHCENTER MALL
Original Plan Submittal
X Response to Correction Letter # 1
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
4-wc
Building Division •
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-13-11
Complete
Comments:
Incomplete
Not Applicable
n
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 01-10-12
Approved n Approved with Conditions Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
• n c qr. a f . :l t�j E '. !4 ,��i. •
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: EL11 -1060 DATE: 11 -28 -11
PROJECT NAME: MACY'S
SITE ADDRESS: 500 SOUTHCENTER MALL
X Original Plan Submittal
Response to Correction Letter #
Response to Incomplete Letter #
Revision # After Permit Issued
DEPARTMENTS:
Building Division
Public Works
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-29-11
Complete
Comments:
Incomplete
Not Applicable
Permit Center Lite Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES /THURS ROUTING:
Please Route Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
APPROVALS OR CORRECTIONS: DUE DATE: 12 -27 -11
Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) N-
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only I 1
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
CityItf Tukwila
REVISION
SUBMITTAL
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Web site: http : //www.ci.tukwila.wa.us
Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through
the mail, fax, etc.
Date:
talgio
Plan Check/Permit Number:
❑ Response to Incomplete Letter #
trResponse to Correction Letter # 11.1
❑ Revision # after Permit is Issued
I!/
r•
E r (---to( co
Revision requested by a City Building Inspector or Plans Examiner
Project Name: 3 S
Project Address: S---o SO 0 -r C.* -t 9t rit
Contact Person: Pku (.- t-1- / S 01\1
Phone Number:
J
mo6-4e9\i -6 q 1' 3
Summary of Revision:
R
e—U1 se—r.0
PLAJs ..1 c
LC- c_-1-12( c_A-
C_
C�122.2c -Tz (n�S
1 D . 0 8 2011
Maw
Sheet Number(s):
"Cloud" or highlight all areas of revision including date of revision
Received at the City of Tukwila Permit Center by:
Entered in Pennits Plus on
H:\gpplintionsTmms- Applications On Line\2010 Appliestio n\7 -2010 - Revision Sobminal.doe
Crested: 8-13 -2004
Revised: 7 -2010
Contractors or Tradespeople Peer Friendly Page
•
Electrical Contractor
A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical
Contractors must maintain a surety bond or assignment of savings account. They also must have a
designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time
supervisory employee.
Business and Licensing Information
Name
Phone
Address
Suite /Apt.
City
State
Zip
County
Business Type
Parent Company
COCHRAN INC
2063671900
Po Box 33524
Seattle
WA
981330524
King
Corporation
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
578042134
Active
COCHRI'088JS
Electrical Contractor
4/10/1992
4/11/2012
General
Unused
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
COCHREC4506KCOCHRAN
ELECTRIC CO INC
Electrical
Contractor
General
Unused
1/12/1955
4/30/1992
Archived
Master Electrician INFORMATION
License HEYWOMD901RF
Name HEYWOOD - COCHRAN, MICHAEL D
Status Active
Business Owner Information
Name
Role
Effective Date
Expiration Date
COCHRAN, ROBERT L
Violation Amount
01/01/1980
6/28/2011
COCHRAN, GORDON W
ELECTRICAL CITATION
01/01/1980
$250.00
COCHRAN - OLSEN, LEEANN G
6/19/2007
01/01/1980
ELECTRICAL CITATION
COCHRAN, ROBERT L
Agent
01/01/1980
10/11/2010
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
TRAVELERS CAS Et
SURETY CO
0815103533100BCM
04/09/2001
Until Cancelled
$4,000.00
01/08/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information No records found for the previous 6 year period
Summons /Complaint Information Summons and Complaints are not filed with the department for this contractor type
Warrant Information Warrants are not filed with the department for this contractor type
Infractions /Citations Information
Infraction / Citation
Date
RCW Code
Type
Status
Violation Amount
EJONV01907
6/28/2011
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$250.00
EBRAQ00227
6/19/2007
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$1,000.00
ECERM00556
10/11/2010
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$2,000.00
ECERM00557
10/11/2010
19.28.101 RCW
ELECTRICAL CITATION
Satisfied
$250.00
https: // fortress .wa.gov /lni/bbip /Print.aspx 01/06/2012