Permit M11-014 - SAHAL CAFE
SAHAL CAFE 13919 TUKWILA INTERNATIONAL BL Mi 1 -014 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us MECHANICAL PERMIT Parcel No.: 8864000980 Address: 13919 TUKWILA INTERNATIONAL BL TUKW Project Name: SAHAL CAFE Permit Number: M11 -014 Issue Date: 03/02/2011 Permit Expires On: 08/29/2011 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: VU THINH TIEN +THU THI 5113 S 284TH PL , AUBURN WA 98001 YOUNG KIM 3828 4 AV S, #7 , SEATTLE WA 98134 YKNWA @YAHOO.COM Phone: 206 355 -9686 MONARCH TRADING CORP Phone: 206 - 763 -6161 PO BOX 80563 , SEATTLE WA 98108 Contractor License No: MONARTC065Q 1 Expiration Date: 03/06/2011 DESCRIPTION OF WORK: INSTALLATION OF TYPE I HOOD Value of Mechanical: Type of Fire Protection: Electrical Service Provided by: $5,000.00 Permit Center Authorized Signature: Fees Collected: $244.88 International Mechanical Code Edition: 2009 Date: 1:1-1 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: - 72// vt5oN This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11-014 Printed: 03 -02 -2011 PERMIT CONDITIONS Permit No. M11 -014 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206 -431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 11: ** *FIRE DEPARTMENT CONDITIONS * ** 12: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: Provide proper slope of horizontal duct and eliminate 90 degree bend where grease could accumulate per International Mechanical Code section 506.3.7 14: Exhaust outlet termination shall comply with International Mechanical Code section 506.3.12. 15: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire - extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire - extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 16: All new automatic fire - extinguishing systems and all modifications to existing automatic fire - extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 17: Local U.L. central station supervision is required. (City Ordinance #2051) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2051) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206- 431 -3670) is required for this doc: IMC -4/10 M11-014 Printed: 03 -02 -2011 project. 1111 • 20: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 21: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 22: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand -held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand -held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 23: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 24: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 25: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4 -3, 4 -4) 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2050 and #2051) 27: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575 -4407. doc: IMC -4/10 M11-014 Printed: 03 -02 -2011 CITY OF TUI Community Deve' nt Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto.1/www.ci.tukwila.wa. us Mechanical *nit No. Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION King Co Assessor's Tax No.:8 8'64 00 — o Gig0 Site Address: r"3 ! ' TO Kw (I—A T ' L- umber: Tenant Name: A-N(. ,S 1-K M / 54/14 L New Tenant: Property Owners Name: M - vu. Floor: i St" ❑ Yes 21 .. No Mailing Address: l3q 1 g Tu K W ILA l N T 1 L ¢3L VO . IUKW (LA City Wq State �(816g Zip CONTACT PERSON — who do we contact when your permit is ready to be issued Name: Mailing Address: 'ouRj I!(1\4 382 fir ,tw Sa. E -Mail Address: n In% Gi I •• • v Day Telephone: SO 6 6 5 -16E6 SEATTLE- WA— cl 131 - City State Zip Fax Number: i—O G 6 2 - O 3 01- MECHANICAL CO TRACTOR INFORMATION Company Name: Mailing Address: City State Zip Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: ARCHITECT OF RECORD — All plans must be stamped by architect of record Company Name: I V V J Al2tH (tE-c-TU E, t L- C- Mailing Address: 33, 2 411-( AN/6- 93 . Contact Person: E -Mail Address: (41•1 to Kt NA 1g.>1w0‘@y&liao. co v\ City Day Telephone: '%6 - -36 6 Fax Number: WA- 61R131- State Zip ENGINEER,OF RECORD — All plans must be stamped by engineer of record Company Name: Mailing Address: City State Zip Contact Person: Day Telephone: E -Mail Address: Fax Number: H:\ Applications\Forms- Application On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 1 of 2 Valuation of project (contractor's bid price $I 0 0 0 Scope of work (please provide detailed information): TYPE Z Ho0 0 Use: Residential: New ❑ Replacement ❑ Replacement Commercial: New Fuel Type: Electric ❑ ❑ Gas Other: Indicate type of mechanical work being installed and the quant'ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler /Compressor 0 -3 hp /100,000 btu Qty furnace <100k btu air handling unit >10,000 cfin fire damper furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment I air handling unit <10,000 cfm incinerator — comm/ind L rapt Z quo0 ) PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: 'o U (`•1(6, -( M Day Telephone: 2-06 - 3 5 5- `f 6 kb Mailing Address: 3 ( Z� 1f1 / v .o. 1 SE-ktTL (j r4 62131 State Zip Date: 3 1 ' 2...0 ft I Date Application Accepted: D ` City Date Application Expires: a 9)t I t HAApplications\Forms- Applications On Line\2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Staff Initials: ET Page 2 of 2 • • �J��1�A wqs City of Tukwila fi Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwi la. wa. us RECEIPT Parcel No.: 8864000980 Permit Number: M11 -014 Address: 13919 TUKWILA INTERNATIONAL BL TUKW Status: APPROVED Suite No: Applied Date: 01/31/2011 Applicant: SAHAL CAFE Issue Date: Receipt No.: R11 -00391 Payment Amount: $195.90 Initials: WER Payment Date: 03/02/2011 02:28 PM User ID: 1655 Balance: $0.00 Payee: KAI WONG TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 002003 ACCOUNT ITEM LIST: Description 195.90 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 195.90 Total: $195.90 doc: Receiot -06 Printed: 03 -02 -2011 1 �J�.`NI�A wqs City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206 - 431 -3665 Web site: http: //www. ci. tukwila. wa. us RECEIPT Parcel No.: 8864000980 Permit Number: M11 -014 Address: 13919 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 01/31/2011 Applicant: SAHAL CAFE Issue Date: Receipt No.: R11 -00179 Initials: User ID: JEM 1165 Payment Amount: $48.98 Payment Date: 01/31/2011 12:43 PM Balance: $195.90 Payee: NW ARCHITECTURE, LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1200 48.98 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 48.98 Total: $48.98 doc: Receiot -06 Printed: 01 -31 -2011 -."•"•• INSPECTION NO. INSPECTION RECORD Retain a copy with permit tit I - 14 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro tit- RA-1 ( iti Type ol kfispection: , I Address: ( -7!-LS Date Called: Special Instructions: Date Wanted: — a.m. *"117rri Requester: Phone No: 7,0 (Z' -3-3 .•••344 Zdet Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Cle 1 ay.& AZ :. e. • ' . Date: .. 7 - 2 5- 4 / . . i 1 ----7 :-• ;..... ,:. SPECTION FEE REQUIRED. Prior to next inspection. fee must be . : .::-...... , .., • ' • INSPECTION RECORD Retain a copy with permit INSPECTIONNO PERMIT N CITY OF TUKWILA BUILDING DIVISION t"4-. 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 n� 11 -d /y Project: t3 d "/t ert�c. Type of Inspectiop: �. /Io'C / 4PST A.5AI -3i /' Tra Dat /C Special Instructions: — Date Wanted: 7- 27.1/ Requester: Phone No: 'Approved per applicable codes. Corrections required prior to approval. COMMENTS j\ +1/ ()T/r'7 .2.....s-v,./,14, 4ffii- o1��C/ , i L,l .otn -i'rt -. f-+7,) /A�... �..=I7/6 .A7 3 �r il)W7" Inspector Date: 7— 77 - '00 REINSPECTION FEE REQUIRED. Prior to inspection. fee must be id at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Receipt No.: Date: • 'INSPECTION RECORD ' Retain a copy with permit CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 INSPECTION NO. riA -o PERMIT N0: DIVISION (206) 431 -3670 Project: S A AM- OAT-E_ Type of Inspection: Ill rat-M-- ..' N Address: lel r P Date Called: Special Instructions: :b1* — oq y e cjA(I A (19 , A C) 14 776`4 - , a t Date Wanted: 3 - ! cs 1 I p. Requester: Phone No: a 64- 34' Lo -oQ I -7 ❑ Approved per applicable codes. giCorrections required prior to approval. 2 i✓l COMMENTS: ett-LA,., S °. Date: 3 —i6.-0l INSPECTION FEE REQUIRED. Priof to next inspection, fee must be - id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 3 3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 A411 -cat Project: A- L- C r 5 Type of Inspection: Address: 1 f 1 Date Called: Speciall II�Insttructions: /� it 'b 2 Sj _ c ( 4 tl "i V Date Wanted: �) / P.m. Requester: Phone No Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: AM 4 eid.4 t52 d, iAd4 4A' ^J44 Inspector: Date: 23 4v/ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /I -g'--/Lit-1 / /-hi- a /, 44/r -0314 I0 ^!yi PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East Tukwila Wa. 98188 2l, Project: ,' - Type of Inspection, r 6fi✓ia I kfoaci 1 / hc, 1 / ec& f ,���„ (like. 'A- /1 Ok Address: ( -3 1 t .- ,-, Suite #: I i 1-4'. , Contact Peron: ►- Special Instructions: Monitor: Phone No.: Ce , tc _ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: A-I 'A- /1 Ok - L4604 s-,pp,o. S, 0y FN w ak /1' c 1-> P41,1 .a Ok_ "` Pore --Ei h ,( (k Monitor: ,r14 i. ,-, Ce , tc _ Pre -Fire: Permits: Occupancy Type: r Needs Shift Inspection: Sprinklers: A-I Fire Alarm: 4 F4 Hood & Duct: Monitor: ,r14 i. ,-, Ce , tc _ Pre -Fire: Permits: Occupancy Type: r Inspector: Date: 7- -1 r` Hrs.: , $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: 1 Company Name: City: Word /Inspection Record Form.Doc State: I Zip: 6/11/10 T.F.D. Form F.P. 113 0413. J±il i Client: Monarch Trading Corp. P.O. Box 80563 Seattle, WA 98101 Contact: King Lee Field Report Report #: 52383 IR* 4251881 58 2?Fa 5881 P$0.1gG101 RECE MED PR 0 R 2011 I ut i- lyV Project Number: 11 -139 Permit #: M11 -014 Project Name: Sahal Coffee Address: 13919 Tukwila International Blvd. Inspection Performed: Welding Date: 3/16/2011 Time: Temperature: On site for the following: 1) Inspected welds for hood duct work. All work completed per detail and minimum AWS D1.1 requirements. Distribution: Distribute Client ❑ Distribute Contractor Distribute Engineer ❑ Distribute Owner Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Blisserd, Jonathan (JD) Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden CORpECOWM�I NrCE aapQnvEn FEB 0 9 2011 City of Tukwila nkwnae la BU nINr in niviSinni Power Roof Ventilators Direct -Drive Upblast Exhaust ®1 For Repair Parts J. all Your Local Brand, Made t �r In LLS.A C C u S 140. 4HZ36 Root Mount FILE COPY JAN 31 2011 No. 41-1Z34 Wall Mount Round mounting plate included Stun i Recommended Dia. i Damper' Wheel Wheel Dimensions (In.) Size Stock Dia. (In.)End (In. At B C 0 E (lo.) No. Recom'd Fixed Root Mounting Curbs' r Ht. 12" Hl. Stock No. Stock No. DIRECT -DRIVE UPBLAST ROOF VENTILATORS 81/4 5/16 1 19 1835 131 114 - 11 1/2 19 2414 233 17% - 11 1/2 22 2414 2335 171i - 13'/. 1/2 22 2414 233 17% - 14% 1/2 26 2814 2435 1944 - 161 5/8 26 28% 24% 1935 - 181 5/8 30 3535 28% 21 - 12 x 12 12 x 12 15 x 15 15x15 19x19 19x19 23 x 23 DIRECT -DRIVE UPBLAST WALL VENTILATORS 81/2 5/16 1 141. 18% 131 1131 1135 8 x 8 ....11 1/2 1935 24% 2314 1734 16% 10 x 10 4HX73 11 1/2 1 1934 24% 233/4 1735 1614 11 z 11 4HX33 131/2 12 1935 24'6 2335 17% 161/2 12 x 12 411X74 - 1414 1/2 221. 28'6 24% 1935 1935 13 x 13 4HX75 161 5/8 221 28% 2435 1934 1935 14 x 14 411X76 - 181 5/8 1 2735 3535 28% 21 25 15 x 15 4HX77 - - (') Not for use with any kitchen exhaust application. (f) 'A' dimension is square tor root ventila- tors and round for wall ventilators. 4HX64 411X65 4HX65 4HX66 4HX66 4HX67 4HX38 4HX38 4HX39 4HX39 4HX40 411X40 4HX41 411X46 4HX46 41047 4HX47 4HX48 4HX48 4HX49 Where's your nearest branch? See pages A3 -A8 for branch listings. Centrifugal Eirect- Driere £Iphlast Exhaust Ventilators Designed for use in restaurants, schools, commercial, and industrial applications to exhaust air contaminated with smoke, fumes, odors, and grease -laden vapors from kitchen range hoods, up and away from the roof (except 8 %,," unit). Feature one piece rolled aluminum outer construction fully welded to the base to create a virtually leakproof seal between the ventilator and the mounting surface. Internal steel support braces and a fully rolled windband dramatically increases the rigidity of the ventilator for increased stability during transportation and installation. Motor, drive frame, and blower wheel are completely isolated from the mounting base by the use of independent neoprene studs, no metal -to -metal contact, greatly reducing overall noise. Motor compartment is isolated from the contaminated air stream and is cooled by outside air that is pulled in through an oversized breather tube by the spinning action of the wheel. • NEMA I junction box located in motor enclosure Disconnect Type No. of Poles Running low on she See pages 2847 -3110 of ow • Aluminum backward inclined, nonoverloading centrifugal wheel design • 11" and larger units have a max. inlet air temp. of 300 °F • 8° units have a max. inlet air temp. of 130 °F • UL-705 Listed for Power Ventilators • 11" and larger units are UL -762 Listed Restaurant Exhaust Appliances (YZEJW) Dayton Electric Mfg Co. certifies that the direct -drive ventilators shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Note: Speed controllers are available for 115V units only. 11 used in a kitchen application check with local code authori- ties for minimum duct velocities. Do not use dampers in any kitchen application. CLITRIED UL 705 Direct and belt -drive Centrifuga Downblast Ventilators are UL Li Ventilators, Subject '705 when p1 complete with specified Dayton drives and for general ventilati( NEMA 1 2 3 Mao. HP 2 71, Stock No. 1H400 111401 NEMA 4 2 3 2 71 111408 Wheel' Dia. Motor (In.) HP RPM* Full Load Amps • Volts Max. BHP Speed Control Sones @ 0.251r SPI 0.000' SP CFM Air Delivery @ RPM Shorn' 0.125' 0.25r 0.375. 0.500' 0.625" 8.750' SP SP SP SP SP SP 0.075' 1.o0(r SP SP : • - Root: Mount.. - Stock - Shpg. • No. Each Wt. ; -. Wall Mount Stock .ShpO• No. - Each Wt. DIRECT 81/2 81/2 -DRIVE UPBLAST ROOF AND WALL VENTILATORS 1/30 1550 1 115 0.03 4YC44 4.1 1/25 1550 1.3 115 0.04 4YC44 4.9 266 424 222 359 172 291 95 204 4HZ32 r $269.75. 23.4 4HZ33 -'.-330:25 -35.0 4HZ34 r $299.25 219 41-1Z35 --.1 371.50 22.6 11 11 1/6 1/4 1140 1725 2.7 5 115 115 0.06 0.20 4YC44 4YC46 8.3 13.0 780 1180 656 1094 502 1017 294 929 824 712 586 - - 4HZ36 ,i 453.00'48:0 4HZ37 r 491.25 50.0 4HZ38 r --481 :75 51.0 4HZ39 -1••• 553.50 540 11 11 1/6 1/4 1140 1725 2.7 5 115 115 0.09 0.29 4YC44 4YC46 6.5 970 12.5 1468 897 1422 806 1373 707 1315 1255 1195 1129 970 - 4HZ40 r 550.50 50.0 4HZ41 r 633.00 53.0 4HZ42 v :619.00 52.0 4HZ43 r- .713.00 55.0 131 1314 1/8 3/4 860 1725 2.7 10.6/5.3 115 115/230 0.07 0.60 4YC44 - 7.7 1180 18.4 2366 1057 2305 914 2244 675 2183 2122 2061 1994 1838 - 4HZ44 v 674.00 :50.0 4HZ45 r 783.50 61.0 4HZ46 r • 741.00 49.0 4HZ47 r ..846.00 63.o 1435 1435 1/8 1/4 860 1140 2.1 3.2 115 115 0.12 0.29 4YC44 4YC46 7.1 1558 11.0 i 2065 1427 1973 1264 1864 1034 1745 1605 1430 1167 - - 4HZ48 v 845.00 58.0 414249 r 920.00 60.0 4HZ50 r 928.00 -52.0 4H251 r 1012.00 62.0 1/4 3/4 860 1140 5 8/4 115 115/230 0.25 0.58 4YC46 4YC45 9.9 1 2472 14.8 3277 2315 3161 2126 3035 1918 2896 1680 2745 - 2587 - 2421 - 1983 - - 4HZ52 r 887.00 76.0 4HZ53 r 958.00 87.0 4HZ54 r 975.50 81.0 4HZ55 •r 1054.00 86.0 18'1 181 1/2 1 860 1140 11.6 11.4/5.7 115 115230 0.40 0.93 - - 1 11.1 3249 16.5 j 4307 3074 4173 2922 4045 2732 3927 2474 3822 2171 3679 1608 3470 - 3284 - 3072 4HZ56 r 1059.001010 411257 r 1092.00118.0 4HZ58 r 1165.00102.0 4HZ59 r 1227.00117.0 (') Performance shown is for installation type A: free inlet, tree outlet. Performance ratings do not include the effects of appurtenances in the airstream. * Speed (RPM) shown is nominal and performance shown is based an actual speed of test. (f) The sound ratings shown are loudness values in fan sones at 5 ft (1.5m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: tree inlet tan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only 4024 j GRAINGER. nnr�r. = Shipped Directly from Manufacturer ✓= Extended Warranty Available *= New Item Made In USA NO.4HX61 Adjustable Vented Curb No. 411X55 Fixed Vented Curb Dayton Made m USA No. 4HX79 Hinge Kit B 11 A9 = Shipped Directly It Fire k: arrier f1 net Wra 20 Commerical Kitchen Grease Duct Fire Protection System Product Data and Installation Instructions NFPA 96 A Compliance 1998 Edition Evaioabcn Rapes 5907 Complies with Complies with International Uniform Mechanical Code Mechanical Code 1. Product Description 3Mrm Fire Barrier Duct Wrap 20A is a fire resistant wrap consisting of a patented inorganic blanket encapsulated with a scrim-reinforced foil. It is used to fire rate commercial kitchen grease ducts and is a proven alternative to 1 or 2 hour fire resistant rated shaft enclosures. This non- asbestos wrap contains a safer fiber construction* and installs easily because of its high flexibility and strength. 3M Fire Barrier Duct Wrap 20A is a two-layer fire resistant wrap system that has passed the ICBO AC101 internal test which simulates a grease duct fire. With its excellent insulating capabilities, it is an ideal choice for tight spaces because it protects combustible constructions at zero clearance. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealants used in combination 3M Fire Barrier Duct Wrap 20A provide an effective firestop when the duct penetrates fire rated walls and floors. Features • Listed to pass the internal grease duct fire test, ICBO AC101 • Zero clearance to combustibles for congested spaces • High flexibility for installation ease • Foil encapsulated with unique center overlap seam for blanket strength, protection and less dust • Safer fiber construction* Has been demonstrated to be soluble in the lungs according to EU guidelines 67/548/EWG, Note Q for bio persistence. 2. Applications 3M Fire Barrier Duct Wrap 20A is an ideal fire resistive enclosure for commercial kitchen grease ducts: It is a proven performance alternative to a 1 or 2 hour fire resistant rated shaft enclosures and provides zero clearance to combustible construction at overlap or collar. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant is used in combination with 3M Fire Barrier Duct Wrap 20A to firestop the duct when the duct penetrates fire rated floors and Walls. 3. Availability Product Unit Size Units / ctn. Wt./ ctn. __ 3M Fire Barrier DuctWras 20A Roll 2 in. x 24 id. x 20 ft. 50mrnx60,9cmx609cm 1 70 lbs. 31 kg 3M Fire Barrier Duct Wra r 20A Roll 2 in. x 48 in. x 20 ft. 50 mm x 121 cm x 609 cm 1 140 lbs. 63 k. 3M Fire Barrier Duct Wrap 20A Collar Roll 2 in. x 6 in. x 20 ft. (50 mm x 152 cm x 609 cm) 4 70 lbs. 31 kg 4. Typical Physical Properties Blanket Color: gray /green Weight: 1.83 lbs. /sq. ft. (8.93 kg /sq. m) Page 2 5. Performance 3M Fire Barrier Duct Wrap 20A has been tested in accordance with the following: ASTM C.,411 ASTM C 518 ASTM E 84 ASTM E 119 ASTM E 136 ASTM E 814 ICBO AC101 Internal Surface Burning Characteristics (ASTM E 84) Foil Encapsulated Blanket: Flame Spread: 0 Smoke Developed: 0 Blanket: Flame Spread: 0 Srnoke Developed: 0 Thermal Conductivity Temperature °F ( °C) btu•in. /(hr.•ft'•F) 500 (260) _ 0.417 1000 (537) 0.922 _ 1500 (815) _ 1.69 1800 (982) 2.27___ _ For technical data and properties of 3M Fire Barrier 1000 N /S, 1003 S/L and 2000+ Silicone Sealants see separate product data sheets available from your 3M representative. Grease Duct Listings Fire Enclosure System Omega Point Lab._Design Nos: Resistive Duct System Through - Rating Penetration _ System 1 or 2 hours 2 layers of 3M Fire Barrier GD 531 F FS 557 W Duct Wrap 20A , 3 in. FS 558 F (76 mm) perimeter and longitudinal overlaps FS 559 W FS 560 F FS 561 F FS 562 W FS563W___ Code Compliance 3M Fire Barrier Duct Wrap 20A complies with requirements of the following codes: NFPA 96, 1998 Edition Uniform Mechanical Code Section 507.6 International Mechanical Code Section 506:3:11 Uniform Building Code Section 711 ICBO ES Evaluation Report No. 5907 This is only a partial list of code compliance. For the latest code and approval information go to www.3m.com /firestop or speak to your authorized 3M distributor or sales representative at (800) 328 -1687. 6. Installation Techniques 3M Fire Barrier Duct Wrap 20A system should be installed in accordance With the following installation instructions. Material and Equipment • 3M Fire Berner Duct Wrap 20A blanket, 2 in. (50 mm) thick, 24 in. (60 cm) or 48 in. (121 cm) wide, 20 ft. (609 cm) standard length. The 48 in. (121 cm) wide blanket helps to minimize waste: • Aluminum foil tape, • Minimum 3/4 in. (19 mm) wide filament tape: • Carbon steel or stainless steel banding material, minimum 1/2 in. (12,7 mm) wide, minimum 0:015 in. (0,38 mm) thick, With steel banding clips. • Hand banding tensioner, crimping tool, and banding cutter. Minimum 12 gauge copper- coated steel insulation pins: galvanized steel speed clips, minimum 1 =1/2 in. (38 mm) square or 1 -1/2 in. (38 mm) dia. round, or equivalent sized insulated cup -head pins; capacitor discharge stud gun. • Access door hardware: four galvanized steel thread rods, 1/4 in: (6 mm) diameter by 4 =1/2 in. to 5 in. long (114 mm to 127 mm) with 1/4 in. (6 mm) wing nuts and 1/4 in. (6 mm) washers: 4 in. (102 mm) long steel hollow tubing to fit threaded rods. • Minimum 4.0 Ib. (1,8 kg) density mineral wool or scrap pieces of 3M Fire Barrier Duct Wrap 20A blanket • 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant: Storage The 3M Fire Barrier Duct Wrap 20A and 3M Fire Barrier 1000 N /S, 1003 S/L and 2000+ Silicone Sealants must be stored in a dry warehouse environment. Pallets should not be stacked. Preparatory Work: 3M Fire Barrier Duct Wrap 20A is installed with common tools, such as knives, banders and capacitor discharge guns for applying insulation pins. In order to install the duct firestop system; the surfaces of all the openings and penetrating items need to be clean, dry, frost free and free of dust: Method: To minimize waste, 3M Fire Barrier Duct Wrap 20A material should be rolled out tautly before measuring: General instructions for installing the 3M Fire Barrier Duct Wrap 20A includes a two -layer wrap construction applied directly to the duct. The first layer or interior wrap of 3M Fire Barrier Duct Wrap 20A shall be cut to a length sufficient to wrap com- pletely around the perimeter of the duct, plus provide an overlap of not Tess than 3 in. (76 mm). Aluminum foil tape is used to seal cut edges of the blanket. Use filament tape to temporarily hold first layer blanket in place. The second layer is applied over the first layer using one of the following methods. Banding is only applied to the exterior layer. There are three (3) approved installation techniques for installing the 3M Fire Barrier Duct Wrap 20A (See Figures 1A -1D and Figures 2A-2D): t Telescoping 3 in. (76 mm) Overlap Wrap With the telescoping overlap wrap method, each blanket overlaps one adjacent blanket; and each blanket has one edge exposed and one edge covered by the next blanket as shown in Figure 1A and 1B. The visible edges of the perimeter oVeriaps all point in the same direction. The next adjacent interior Wrap of 3M Fire Barrier Duct Wrap 20A shall be cut to completely wrap around the perimeter of the duct with enough excess to provide an overlap of not less than 3 in. (76 mm). A minimum 3 in. (76 mm) longitudinal overlap onto the previous adjacent wrap is required on both layers. The second layer or exterior wrap of 3M Fire Barrier Duct Wrap 20A should be cut to sufficient length to wrap completely around the perimeter of the interior wrap with sufficient excess to provide an overlap of not less than 3 in. (76 mm). The 3M Fire Barrier Duct Wrap 20A to be installed as the exterior layer Shall be cut, if needed, and properly located to ensure that the longitudinal overlap joints of the exterior layer of blanket are staggered 10 -1/2 in. (26,7cm) from those of the interior layer: Aluminum foil tape is used to seal any cut edges of the blanket. 2. Checkerboard 3 in. (76 mm) Overlap Wrap With the 3 in. (76 mm) checkerboard overlap wrap method, blankets with both edges exposed alternate with blankets with covered edges, as shown in Figure 10. The visible edges of the perimeter overlaps alternate their directions and appear on every other blanket. 3. Butt Joint With Collar With the butt joint and collar overlap method; adjacent blankets are butted tightly together and 6 in. (152 mm) wide collar of 3M Fire Barrier Duct Wrap 20A is centered over the joint, overlapping each blanket by 3 in: (76 rnrn) as shown in Figure 1D. In all three overlap techniques the perimeter overlap can occur at any location on the duct. The blanket is mechanically attached to the duct by steel banding or by welded insulation pins and clips for all three installation methods listed above. For Banding Only (See Figures 1A to 1D) Filament tape can be used to temporarily hold the blanket in place until the banding is applied. The steel banding is applied around the duct 1 -1/2 in. (38 mm) from each edge of the blanket, and 10 -1/2 in. (26,7 cm) maximum centers. The banding is placed around the exterior layer of material and tightened so as to sufficiently hold the 3M Fire Barrier Duct Wrap 20A in place against the duct, compressing the foil but not cutting the foil. Page 3 Additional Pinning to Prevent Sagging of the Wrap: For Ducts 24 in: (60 cm) and larger in width, additional pins are needed to support the blanket on the bottom horizontal surface and on the outside face of a vertical duct run. Space pins a maximum of 10 -1/2 in. (26,7 cm) apart in the direction of the blanket width, and a maximum of 12 in. (30 cm) apart in the direction of the blanket length: Refer to paragraph below for more information on Mechanical Fastening with Pins. For Mechanical Fastening with Pins Only (See Figure 2A to 2D) Insulation pins are welded to the duct in the centers of the overlaps a minimum of 1 -1/2 in. (38 mm) from each edge of the blanket, and spaced a maximum of 8 in. (27 mm) on center along perimeter overlap, and a maximum of 10 -1/2 in. (38 mm) on center along longitudinal overlaps. The blanket is impaled over the pins and held in place by galvanized speed clips. Insulation pins that extend beyond the blanket wrap shall be turned down to eliminate sharp points. Insulated cup -head pins can be used at the same spacing requirements of the insulation pins. NOTE: Support hangar systems do not need to be wrapped provided the hangar rods are at least a minimum of 3/8 in. (9,53 mm) diameter and spaced a maximum of 60 in. (152,4 cm) on center along the length of the duct. Use a minimum 2 in. x 2 in. x 1/4 in. (50 mm x 50 mm x 6,35 mm) steel angle steel support channel or SMACNA equivalent support system. Access Door Installation (See Figure 3) Four galvanized steel threaded rods, 1/4 in. diameter (6,35 mm) by 6 -1/2 in. to 7 in. long (165 mm to 177 mm) are welded to the duct at the corners of the door opening. Four steel tubes, each 5 in. to 7 in. (127 mm to 165 mm) long, are placed over the rods to act as protection for the 3M Fire Barrier Duct Wrap 20A when fastening the door. Four insulation pins are welded to the door panel for installation of the blan- ket. One layer of 3M Fire Barrier Duct Wrap 20A is cut so as the approximately the same size as the access door panel and impaled over the insulation pins. It is essential that this layer fit tightly against the wrap surrounding the access door opening with no through openings. A second layer of 3M Fire Barrier Duct Wrap 20A is cut so as to overlap the first layer by a minimum of 1 in. (25 mm) on all sides. A third layer of 3M Fire Barrier Duct Wrap 20A is cut to overlap the second layer by 1 in (25 mm) on all sides. The layers are impaled over the welding pins and all layers are Page 4 locked in place with galvanized speed clips. Pins that extend beyond the outer layer of 3M Fire Barrier Duct Wrap 20A shall be turned down to avoid sharp points on the door: The insulated door panel is placed over the threaded rods and held in place with washers and wing nuts. The details are shown in Figure 3. Penetrations (See Figures 4A to 4D) When the duct penetrates a fire rated wall, ceiling or floor, an approved firestop system must be employed. Figures 4A to 4D illustrate typical conditions. To firestop the wrapped duct, follow the installation parameters detailed in the following Omega Point Laboratories, Inc. systems: FS 557 W, FS 558 F, FS 559 W, FS 560 F, FS 561 F, FS 562 W, FS 563 W. Other Applications Refer to Figures 5, 6, 7, 8 and 9 for additional typical conditions. 7. Maintenance No maintenance is required when installed in accordance with the 3M Installation Instructions. Once installed, if any section of the 3M Fire Barrier Duct Wrap 20A is damaged so that the blanket is damaged, the following procedures will apply: • The damaged section should be removed by cutting the steel banding or removing the clips holding it in place. • A new section of the same dimension should be cut from a roll of 3M Fire Barrier Duct Wrap 20A, either 24 in. (60,9 cm) or 48 in. (121 cm) wide. • The new section should be placed and fitted ensuring the same overlap that existed previously. • The steel banding should be placed around the material and tensioned so as to sufficiently hold the 3M Fire Barrier Duct Wrap 20A in place. • If the blanket has not been damaged but the foil has ripped, seal the rip with aluminum foil tape. 8. Purchase Information 3M Fire Barrier products are available through a network of nationwide distributors. For information on where to buy, go to www.3m.com /firestop. 9. Safe Handling Information Consult Material Safety Data Sheet prior to handling and disposing of 3M Fire Barrier Duct Figure 1A 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Telescoping Wrap Technique With Bantling For Ducts 24 inches (60,9 cm) or Less Wrap 20A. 1A. First Layer 3M Fire Barrier Duct Wrap 20A_ __ 1 B. Second Layer 3M Fire Barrier Duct Wrap 20A 2. Steel Banding 1/2 in. (13 mm) Wide Min. Typical 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap System integrity is limited by quality of installation. Page 5 Figure 1B Telescoping Overlap Wrap Option Cross Sectional View Figure 1C Checkerboard Overlap Wrap Option Cross Sectional View 21" (53,3 Typ. Figure 1D Butt Joint With Collar Option Cross Sectional View 6" (152 mm) 3" (76 mm) 1=1/2" (38 1 /2" (38 mm) {6) 12" (30,4 cm) 1A. First Layer 3M Fire Barrier Duct Wrap 20A 1B. Second Layer 3M Fire Barrier Duct Wrap 20A Steel Banding 1/2 in. (13 mm) Wide Min. Typical _ 3. 3 in. (76 mm) Min: Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap 5. 6 in. (152 mm) Wide Collar: Prefabricated 3M Fire Barrier 20A Collar 6. Firmly Butted Joint System integrity is limited by quality of installation. Page 6 Figure 2A 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease.,Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Telescoping Wrap Technique With Weld Pins Only 1A. First Layer_3M_ Fire Barrier_Duct Wrap 20A 1B. Second Layer 3M Fire Barrier Duct Wrap 20A 2. 1 -1/2 in. Square (38 mm) or 1 -1/2 Dia. (38 mm) Galvanized Speed Clips 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap System integrity is limited by quality of installation. Page 7 Figure 2B Telescoping Overlap Wrap Option Cross Sectional View 3" (76 mm) 1 -1/2" (38 mm) 0 21" (53,3 cm) Typ. 3" (76 mm) 1-1/2" (38 mm) Figure 2C Checkerboard Overlap Wrap Option Cross Sectional View 3" (76 mm) 1-1/2" (38 mm) 1B 3" (76 mm) 1-1/2" (38 mm) 21" (53,3 cm) Typ. Figure 2D Butt Joint With Collar Option Cross Sectional View 6" (152 mm) 3" (76 mm) 1-1/2" (38 mm 1 /2" (38 mm) 1 2 ' (30,4 cm) 1A. First Layer 3M Fire Barrier Duct Wrap 20A 1B. Second Layer 3M Fire Barrier Duct Wrap 20A 2. 1 -1/2 in. Square (38 mm) or 1 -1/2 Dia. (38 mm) Galvanized Speed Clips 3. 3 in. (76 mm) Min. Longitudinal Overlap 4. 3 in. (76 mm) Min. Perimeter Overlap 5. 6 in. (152 mm) Wide Collar: Prefabricated 3M Fire Barrier 20A Collar 6. Firmly Butted Joint System integrity is limited by quality of installation. Page 8 Figure 3 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Access Door System 1: Access Hole 2. 1/4 in. (6 rnm) Dia. All Threaded Rods 3. Access Cover — 16 Gauge 4. Insulation Pins — Welded 5. First Layer 3M Fire Barrier Duct Wrap 20A Cut Same Size As Cover 6. Second Layer 3M Fire Barrier Duct Wrap 20A with 1 in. (25mm) Overlap On All Sides 7. Third Layer 3M Fire Barrier Duct Wrap 20A with 1 in. (25mm) Overlap On All Sides of Previous Layer 8. Speed Clips 9. _ Aluminum Tape Covering All Exposed Edges 10. Spool Pieces For Threaded Rods 11. 1/4 in: (6mm) Diameter Wing Nuts_ _ _ System integrity is limited by quality of installation. r Page 9 Figure 4A 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration, Systems 4 -1/2 inch (11,4 cm) Concrete Floor or Wall 3„ 76 mm) 1. Floor /Ceiling or Wall Assembly 2. Duct 3A: Two Layers 3M Fire Barrier Duct Wrap 20A 3B Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N /S, 1003 S/L or 2000+ Silicone Sealant For Wall Assembly Apply Sealant To Both Side "s of Wall System integrity is limited by quality of installation. Page 10 (76 mm) Omega Point Laboraties, Inc. Through Penetration Systems FS 560 F FS 562 W Figure 4B 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration Systems Fire -Rated Gypsum Wallboard 3" (76 mm 3" 1A. Studs 1 B: Gypsum W allboard 2. Duct 3A. Two Layers 3M Fire Barrier Duct Wrap 20A 3B. Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N/S or 2000+ Silicone Sealant_ System integrity is limited by quality of installation, 76 mm) Omega Point Laboraties, Inc. Through Penetration Systems FS 557 W FS 559 W Page 11 3B Figure 4C 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Through Penetration. Systems 4 -1/2 inch (11,4 cm) Concrete Floor or Wall 3A Cdr 1. Floor /Ceiling or Wall Assembly 2. Duct - 3A. Each Two Layers 3M Fire Barrier Duct Wrap 20A — Terminated on Side of Floor or Wall Penetration. 3B Banding or Pinning 3C. Packing Material 3D. 3M Fire Barrier 1000 N /S; 1003 S/L or 2000+ Silicone Sealant For Wall Assembly Apply Sealant To_Both Sides of Wall System integrity is limited by quality of installation. Page 12 Omega Point Laboraties, Inc. Through Penetration Systems FS 561 F FS 563 W Figure 4D 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 Hour Through Penetration Systems Fire -Rated Wood /Gypsum - Floor /Ceiling Assembly 1. _ Fire -rated Floor /Ceiling Assembly - 2. Duct 3A. Two Layers 3M Fire Barrier Duct Wrap 20A 3B Banding or Pinning - 3C: Packing Material 3D. 3M Fire Barrier 1000 N /S; 1003 S/L or 2000+ Silicone Sealant__ System integrity is limited by quality of installation. Omega Point Laboraties, Inc. Through Penetration Systems FS 558 F Page 13 3" Figure 5 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems Suggested 1 or 2 Hour Three Sided Wrap 76 mm) 6 1. Concrete Slab 2. Two Layers 3M Fire Barrier Duct Wrap 20A 3. Concrete Fasteners - Minimum 1/4 in. (6 mm) Dia. Steel Concrete Anchors 4. O:C. 1/8 in. (3mm) Thick x 2 in. -3in. (50mm - 76mm) Wide Bar Stock Perforated 12 in. (30 cm) 5. Duct _ 6. Banding 7. Banding Clips Page 14 Figure 6 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems Suggested 1 or 2 Two Hour Two Sided Wrap 3" (76 mm) 1 a 1. Concrete Slab 2. Two Layers 3M Fire Barrier Duct Wrap 20A 3. Concrete Fasteners - Minimum 1/4 in. (6 mm) Dia. Steel Concrete Anchors 4. 1/8 in. (3 mm) Thick x 2 in. -3 in. (50 mm — 76 mm) Wide Bar Stock Perforated 12 in. (30 cm) O.C. 5. Duct 6. Banding 7. Banding Clips System integrity is limited by quality of installation. Page 15 Figure 7 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Exhaust Hood 2. 3. 4. Hood Two Layers 3M Fire Barrier Duct Wrap 20A 6 in. (152 mm) Minimum Overlap Banding Page 16 Figure 8 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Roof Vent 1. Duct 2. Roof Assembly 3. Roof Flashing 4. Vent Flashing 5. Two Layers 3M Fire BarrierDuct Wrap 20A 6. Firestopping System for Rated Roof Assemblies Only Page 17 Figure 9 3M Fire Barrier Duct Wrap 20A Commercial Kitchen Grease Duct Systems 1 or 2 Hour Shaft Alternative Zero Clearance to Combustibles Suggested Vertical Support 3" (76 mm) MIN. TYP. 1. First Layer 3M Fire Barrier Duct Wrap 20A 2. Second Layer 3M Fire Barrier Duct Wrap 20A 3. Mechanical F asteners and Washers 4: Duct 5_. Rated Floor /Ceiling ___ 6_ Firestopping System 7. _Banding 8: Support Channel Page 18 Page 19 Warranty and Limited Remedy. This product will be free from defects in material and manufacture for a peri- od of ninety (90) days from date of purchase. 3M MAKES NO OTHER WARRANTIES INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OR MERCHANTIBILITY OR FITNESS FOR A PARTICULAR PURPOSE. User is responsible for determining whether the 3M product is fit for a particular purpose and suitable for user's method of application. If this 3M product is proved to be defective within the warranty period stated above, your exclusive remedy and 3M's sole obligation shall be, at 3M's option, to replace or repair the 3M product or refund the purchase price of the product. Limitation of Liability. Except where prohibited by law, 3M will not be liable for any Toss or damages arising from the use of this 3M product, whether direct, indirect, special, incidental or consequential, regardless of the legal theory asserted, including warranty, contract, negligence or strict liability. Specified Construction Products Department 3M Center 223 -2N -21 St. Paul, MN 55144 -1000 (800) 328-1687 Printed in U.S.A. © 3M 2001 98- 0400 - 5055 -5 (July 2001) • HERMIT COORD COPYf PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -014 DATE: 01/31/11 PROJECT NAME: SAHAL CAFE SITE ADDRESS: 13919 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPART ENTS: ui ding 'vision Public Works C Fire Prevention Structural Planning Division Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete n Complete Comments: DUE DATE: 02/01/11 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/01/11 Approved Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 Contractors or Tradespeople Pr ter Friendly Page • Page 1 of 2 r General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MONARCH TRADING CORP UBI No. 600465574 Phone 2067636161 Status Active Address Po Box 80563 License No. MONARTC065Q1 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 11/21/1994 State WA Expiration Date 3/6/2013 Zip 98108 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date LEE, KING T President 01/01/1980 Bond Amount WOO, LILY NGAN Secretary 01/01/1980 LPM4078819 WONG, AMY W Treasurer 01/01/1980 WONG, KAI Vice President 01/01/1980 CBIC Bond Information Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 COLONIAL AM CAS a SURETY OF MARYLAND LPM4078819 08/12/2009 Until Cancelled $12,000.0007/20 /2009 3 CBIC SB0540 02/14/2002 Until Cancelled 08/12/2009 $12,000.0002/20 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 9 AMERICAN ECONOMY INS CO 02BP1636128 02/14/2011 02/14/2012 $1,000,000.0001 /11/2011 8 AMERICAN ECONOMY INS 02BP1636127 02/14/2010 02/14/2011 $1,000,000.0001 /22/2010 https://fortress.wa.gov/lniibbip/Print.aspx 03/02/2011 NON - COMBUSTIBLE 1 HR. RATED CLG. co a) -H EXIST. KEYSTONE WALL ACCESSIBLE PA 1;G SIGN PAVE THt•.ACcESSIBLE PARK'G LOT & ROUtE,, I 280 \ 12"x12" OR EQUIVALENT N 7 AREA. 16 GA. GAL.. ALL V /J / WELDED MAKE -UP AIR DUCT FRESH AIR INTAKE HOOD SIDE ELEVATION SCALE 1/2" = 1' -0" MIN. CLR. 4 /\ p f FILTERS S.S. GREASE CUP 6 "MIN. • • • • • • • • • • • 10' MIN. TO ANY AIR INTAKE, AND PROPERTY LINE IN ANY DIRECTION; 10' MIN FROM SAME OR ADJACENT BUILDING. < 10' MIN. TO ANY HAZARDOUS OR NOXIOUS CONTAMINATE ,SOURCE 1 HR MIN. FIRE WRAP 12 "x12" OR EQUIVALENT AREA. 16 GA. GAL.. ALL WELDED EXHAUST DUCT HOOD WALL HANGER 3" AIR SPACE 1 HOUR RATED NON- COMBUSTIBLE WALL (EXIST.) 22 GA. S.S. FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES MAKE -UP AIR EXHAUST FAN AIR INTAKE FILTER & FAN 12 "x 12" OR EQUIVALENT AREA, 24 GA. MIN. MAKE -UP AIR DUCT 12 "x12" OR EQUIVALENT AREA. 16 GA. GALV. ALL WELDED EXHAUST DUCT 1 SEAL DUCT 18" AROUND AT THE POINT OF PENETRATION W/ 22 GA. STEEL. TYP. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. EXIST. BLDG. STRUCTURE, NO CHANGE 1 HR MIN. FIRE WRAP ANKOMMMWOMMOMMMMUN0, , MAKE -UP\ AIR COCN. WALL, VERIFY IN FIELD. HOOD SHALL BE LISTED FOR USE OVER HEAVY DUTY COOKING APPLIANCES. 22 GA. S.S. FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES NOTE: PROVIDE A MEANS TO AUTOMATICALLY START THE HOOD FAN AND MAKE -UP AIR UNIT FAN WHEN ANY COOKING APPLIANCE IS ENERGIZED. UL LISTED 6' TYPE EXHAUST HOOD 6 "MIN. 6„ MIN. DEEP FRYER 14' -0" w N CD L Li 6 "M1N P 2 CO 1'-6" MIN. 1 HR. RATED CLG., TYP. HOOD FRONT /BACK ELEV. SCALE 1 /2" = 1' -0" SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical electrical Ilehumbing Gieas Piping City of Tukwila BillU7ING DIVISION NOTE: COOKING EQ. TO BE DETERMINED WHEN INSTALLATION. SHOWN ABOVE IS CONCEPTIONAL FOR REFERENCE 19' —O" PAVE DRIVEWAY MIN. `20' 110' REQ'D 1 HR. RATED b EXT. WALL (EXIST.), VERIFY IN FIELD TYPE I HOOD EXHAUST MAKE -UP FAN 6 LLD oi EXIST. HOUSE 10 280 92.64 COMMERCIAL USE C.L. 140TH ST. GREASE DUCT TEST (2009 IMC 506.3.2.5) Prior to the use or concealment of any portion of a grease duct system, a leak test shall be preformed, Ducts shall be considered to be concealed where installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on all sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease duct leakage test. A light test shall be performed to determine that all welded and brazed joints are liquid tight. A light test shall be performed by passing a lamp having a power rating of not less than 100 watts through the entire section of ductwork to be tested. The lamp shall be open so as to emit light equally in all directions perpendicular the duct walls. Test shall be performed for the entire duct system, including the hood -to -duct connections. The duct work shall be permitted to be tested in sections, provided that every joint is tested. For listed factory -built grease ducts, this test shall be limited to the duct joints assembled in the field and shall include factory welds. PROJECT AREA VI \CINITY � SCALE N.T.S. 'IAP 139TH ST 140TH ST. FILE COPY Permit No.. rt‘V` 0 19 Plan review approval Is abject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ardlnance. Receipt of app F=ield Copy and conditions 15 acknowledged: By Date: UL LISTED SCREW IN OM PACT FLUORESCENT ULB, TYP. H: 28 TO 30" �- y °fr AIR SPACE 42", 45", 48", 51" SITE PLAN SCALE 1"= 20' -0" NOTE: 1. DUCT COLLAR CENTERED ON "L" DIMENSION. 2. CONSULT FACTORY FOR ALTERNATE COLLAR LOCATIONS. 3. COLLAR SIZE BASED ON 1600 TPM. L 18' -0" MAX. LENGTH \ IIN. EXHAUST FAN U N. ELEV.: WALL MOU SCALE 1/4"=1' -0" \IT VENT. 3' SEE CHART FOR MIN. "W" OR OVERHANGE City Of lbkwiia BUILDING DIVISION NOTE: (1) HOOD 8' -0" LONG TYPE I COMPENSATING S.S WALL CANOPY HOOD. UL LISTED AND NSF APPROVED MODEL TO BE USED. MIN. 20 GA. TYPE 304 OR TYPE 430 STAINLESS STEEL CONSTRUCTION WITH # 4 FINISH AT EXPOSED SURFACE; EXHAUST PLENUM: 16 GA. GALVANIZED STEEL ALL WELDED; FILTER BANK: SUPPLIED WITH UL. CLASSIFIED 20 x 20 x 2 REMOVABLE BAFFLE TYPE; GREASE RECEPTACLE: PROVIDE AT LEST ONE REMOVABLE GREASE RECEPTACLES. (2) EXHAUST DUCTS - 12"x12' 17 "x17" OR EQUIVALENT AREA MIN., 16 GA. GALVANIZED STEEL ALL WELDED CONSTRUCTION. ONE HOOD OUTLET SHALL SERVE NOT MORE THAN A 18' -0" SECTION OF HOOD PER UL LISTED HOOD. (3) CONTINUOUS ENCLOSURE CONSTRUCTION - 3M FIRE BARRIER DUCT WRAP (ONE HR MIN. FIRE RATED UL, ICBO, ASTM TESTED AND LISTED PRODUCT) CONTINUOUS DUCT ENCLOSURE SHALL BE SEALED AROUND THE DUCT AT THE POINT OF PENETRATION AND VENTED TO THE EXTERIOR THROUGH WEATHER PROTECTED OPENING. (4) EXHAUST FAN - DAYTON, GREASE TYPE KITCHEN EXHAUST BLOWER, 4HZ53, UP BLAST ROOF MOUNT. 3277 CFM @1140 RPM, 115/230 V, 8/4 AMPS, 3/4 HP. NOISE: 14.8 SONES(A) (SEE ATTACHED MANUFACTORY DOCUMENT FOR DETAILED SPECIFICATIONS) (5) MAKE -UP FAN - DAYTON 4TM06 BELT DRIVE BLOWER. SIDE DRAFT, 2958 CFM @0.0 SP, 1725 RPM, 115/230 V, 1 PH, 1/4 HP (SEE ATTACHED MANUFACTORY DOCUMENT FOR DETAILED SPECIFICATIONS) (6) EXHAUST FAN, MAKE -UP FAN AND GAS LINE TO BE ELECTRICALLY INTERLOCKED; (7) FIRE SUPPRESSION SYSTEM BY OTHERS SHOULD PROVIDE SEPARATE PLAN FOR APPROVAL. WORK WILL CONFORM TO UL 300, NFPA96, IBC'09, IMC'09, AND ALL LOCAL, STATE CODES AND INSURANCE REQUIREMENT; (8) ALL DESIGN AND WORK WILL CONFORM TO IMC'09, UL 300, NFPA96, ALL LOCAL, STATE CODES AND INSURANCE REQ'T. HOOD EXHAUST & MAKE —UP AIR CALCULATIONS 3/8 -16 ALL THREAD ROD CONNECTED TO ROOF JOIST BY OTHERS. 3/8 -16 HEAVY DUTY LOCK NUT ONE ABOVE AND ONE BELOW HANGER BRACKET BY OTHERS. STAINLESS STEEL HANGER BRACKET NOTE: 1. TREADED ROD AND LOCK NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR. 2. HANGER BRACKET IS PRE - PUNCHED AT FACTORY STANDARD FEATURES - UL LISTED #46AJ - NSF APPROVED #D031638 - CONFORMS TO NFPA STANDARD #96 - SQUARE BOX DESIGN w - 3" AIR SPACE AT REAR - TYPE 304 STAINLESS STELL WHERE K' cn EXPOSED WITH #4 FINISH - FACTORY INSTALLED DUCT COLLAR - UL LISTED GREASE TYPE BAFFLE FILTERS - REMOVABLE GREASE COLLECTORE - PRE -WIRED VAPOR -PROOF LIGHTS - SUPPORT BRACKETS AIR SPACE INSTALL. & OPERAT'G INSTRUCTIONS SCALE 1/2" = 1' -0" INSTALLATION: THE EXHAUST AND SUPPLY AIR FLOW RATE WERE ESTABLISHED UNDER CONTROLLED LABORATORY CONDITIONS: UL LISTED EXHAUST AIRFLOW RATE AT 400 CFM /FT OF CAPTURE AREA LENGTH. UL LISTED HOOD OUTLET SHALL SERVE NOT MORE THAN 18 -FOOT SECTION OF HOOD. - GREATER EXHAUST AND /OR LESSER SUPPLY AIR IS REQUIRED FOR COMPLETE VAPOR AND SMOKE REMOVAL IN SPECIFIC INSTALLATION. - 6" MINIMUM OVERHANG FROM OPEN SIDES AND FRONT SIDE OF HOOD. - THE EXHAUST AND MAKE -UP AIR SYSTEMS SHALL BE CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH. LIGHTING: ONE 120VAC MAX. 12 AMPS ADD'L JST.,TYP. EXIST. JST.,TYP. 2' -8 ", TYP. 1 -4 ", TYP. 2x8 BLKG. W/ SIMPTSON A35 CLIP EA SIDE, TYP. @ EA END OF BLKG HANGING ANGLE (MIN. 3/16" THK. BY HOOD MNFR.) 3/8 -16 ALL THREAD ROD TYP 4 EXHAUST DUCT ONE LAYER FIRE MASTER FAST WRAP 1.5" THICK OR EQUIVALENT 3" MIN. OVER LAY. TYP. STEEL BANDING 1/2" WIDE MIN. OR PINNING. TYP. FIRE WRAP MATERIAL: PRODUCT: 3M FIRE BARRIER DUCT WRAP 15A. IS NON - ASBESTOS CONTAIN A SAFER FIBER CONSTRUCTION AND CONSISTING OF A PATENTED INORGANIC BLANKET ENCAPSULATED WITH A SCRIM - REINFORCED FOIL. SPECIALLY USED TO FIRE RATE COMMERCIAL KITCHEN GREASE DUCT AND IS A PROVEN ALTERNATIVE TO 1 OR 2 HOUR FIRE RESISTANT RATED SHAFT ENCLOSURES. PERFORMANCE: 3M FIRE BARRIER DUCT WRAP 15A HAS BEEN TESTED IN ACCORDANCE WITH THE STANDARDS OF ASTM C 411, ASTM C 518, ASTM E 84, ASTM E 119, ASTM E 136, ASTM E 814, UL 1978 (SECTIONS 12 & 13) AND UL 910. SEE ATTACHED PRODUCT DATA SHEET FOR OTHER SPECIFICATIONS AND DETAIL. TYP. FIRE WRAP OVERLAY DETAIL SCALE 1/2" = 1' -0" SECTION 1 3/8 -16 HEAVY DUTY LOCK NUT ONE ABOVE AND ONE BELOW HANGER BRACKET, TYP 4 STAINLESS STEEL HANGER BRACKET HOOD - REVIEWED FOR CODE COMPLIANCE iAMIMED [L3 09 2011 W ` City of Tukwila BUILDING DIVISION 22 GA. S.S. FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES HOOD MOUNTING DETAIL SCALE NONE METAL STUD WALL EXIST. JST., TYP. 2x12 ATTACHED TO THE EXIST., TYP. SIMPSON "U210," TYP. (2) 2x12, TYP. SIMPSON "HUS212 -2," AT (2) JOISTS, TYP. 17x17 HOOD FIRE WRAP, TYP. MIN. 3' SPACING, TYP. HOOD FRAM'G (NOT USED) SCALE 1 1/2 " =1' -0" CITY ., LA JAN 212011 PERMIT CRIER SECURE HOOD WALL ATTACHMENT BRACKETS TO METAL STUD @ 24" INTERVAL USING SHEET METAL SCREWS 5/8" GWB MII -ol NO. REVISION DATE PROJECT TITLE /OWNER SAHAL CAFE/ BARBER 13919 TUKWILA INT'L BLVD. TUKWILA, WA 98168 CONTACT: ANIS A MED 206) 334 -3424 TYPE I HOOD NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 REGISTRATION 8171 REGISTERED ARCHITECT UNG T. SKIM TATE OF WASHINGTON NWA PROJECT NO. HOOD RATE REQUIRED -- CHK BY YK DATE (LF) (CFM /LF) HOOD CFM DUCT SIZE DUCT AREA FPM EXHAUST 6' 400 2,400 12 "x12 "/144 1.00 SF 2,400 MAKE -UP 90% OF EXHAUST 2,1,60_ 12 "x1-2 "/144 1.00 SF_ 2,160. 3/8 -16 ALL THREAD ROD CONNECTED TO ROOF JOIST BY OTHERS. 3/8 -16 HEAVY DUTY LOCK NUT ONE ABOVE AND ONE BELOW HANGER BRACKET BY OTHERS. STAINLESS STEEL HANGER BRACKET NOTE: 1. TREADED ROD AND LOCK NUTS TO BE SUPPLIED BY INSTALLING CONTRACTOR. 2. HANGER BRACKET IS PRE - PUNCHED AT FACTORY STANDARD FEATURES - UL LISTED #46AJ - NSF APPROVED #D031638 - CONFORMS TO NFPA STANDARD #96 - SQUARE BOX DESIGN w - 3" AIR SPACE AT REAR - TYPE 304 STAINLESS STELL WHERE K' cn EXPOSED WITH #4 FINISH - FACTORY INSTALLED DUCT COLLAR - UL LISTED GREASE TYPE BAFFLE FILTERS - REMOVABLE GREASE COLLECTORE - PRE -WIRED VAPOR -PROOF LIGHTS - SUPPORT BRACKETS AIR SPACE INSTALL. & OPERAT'G INSTRUCTIONS SCALE 1/2" = 1' -0" INSTALLATION: THE EXHAUST AND SUPPLY AIR FLOW RATE WERE ESTABLISHED UNDER CONTROLLED LABORATORY CONDITIONS: UL LISTED EXHAUST AIRFLOW RATE AT 400 CFM /FT OF CAPTURE AREA LENGTH. UL LISTED HOOD OUTLET SHALL SERVE NOT MORE THAN 18 -FOOT SECTION OF HOOD. - GREATER EXHAUST AND /OR LESSER SUPPLY AIR IS REQUIRED FOR COMPLETE VAPOR AND SMOKE REMOVAL IN SPECIFIC INSTALLATION. - 6" MINIMUM OVERHANG FROM OPEN SIDES AND FRONT SIDE OF HOOD. - THE EXHAUST AND MAKE -UP AIR SYSTEMS SHALL BE CONNECTED BY AN ELECTRICAL INTERLOCKING SWITCH. LIGHTING: ONE 120VAC MAX. 12 AMPS ADD'L JST.,TYP. EXIST. JST.,TYP. 2' -8 ", TYP. 1 -4 ", TYP. 2x8 BLKG. W/ SIMPTSON A35 CLIP EA SIDE, TYP. @ EA END OF BLKG HANGING ANGLE (MIN. 3/16" THK. BY HOOD MNFR.) 3/8 -16 ALL THREAD ROD TYP 4 EXHAUST DUCT ONE LAYER FIRE MASTER FAST WRAP 1.5" THICK OR EQUIVALENT 3" MIN. OVER LAY. TYP. STEEL BANDING 1/2" WIDE MIN. OR PINNING. TYP. FIRE WRAP MATERIAL: PRODUCT: 3M FIRE BARRIER DUCT WRAP 15A. IS NON - ASBESTOS CONTAIN A SAFER FIBER CONSTRUCTION AND CONSISTING OF A PATENTED INORGANIC BLANKET ENCAPSULATED WITH A SCRIM - REINFORCED FOIL. SPECIALLY USED TO FIRE RATE COMMERCIAL KITCHEN GREASE DUCT AND IS A PROVEN ALTERNATIVE TO 1 OR 2 HOUR FIRE RESISTANT RATED SHAFT ENCLOSURES. PERFORMANCE: 3M FIRE BARRIER DUCT WRAP 15A HAS BEEN TESTED IN ACCORDANCE WITH THE STANDARDS OF ASTM C 411, ASTM C 518, ASTM E 84, ASTM E 119, ASTM E 136, ASTM E 814, UL 1978 (SECTIONS 12 & 13) AND UL 910. SEE ATTACHED PRODUCT DATA SHEET FOR OTHER SPECIFICATIONS AND DETAIL. TYP. FIRE WRAP OVERLAY DETAIL SCALE 1/2" = 1' -0" SECTION 1 3/8 -16 HEAVY DUTY LOCK NUT ONE ABOVE AND ONE BELOW HANGER BRACKET, TYP 4 STAINLESS STEEL HANGER BRACKET HOOD - REVIEWED FOR CODE COMPLIANCE iAMIMED [L3 09 2011 W ` City of Tukwila BUILDING DIVISION 22 GA. S.S. FLASHING. 18" MIN. OVER EXHAUST HOOD AND DUCT TOP AND SIDE EDGES HOOD MOUNTING DETAIL SCALE NONE METAL STUD WALL EXIST. JST., TYP. 2x12 ATTACHED TO THE EXIST., TYP. SIMPSON "U210," TYP. (2) 2x12, TYP. SIMPSON "HUS212 -2," AT (2) JOISTS, TYP. 17x17 HOOD FIRE WRAP, TYP. MIN. 3' SPACING, TYP. HOOD FRAM'G (NOT USED) SCALE 1 1/2 " =1' -0" CITY ., LA JAN 212011 PERMIT CRIER SECURE HOOD WALL ATTACHMENT BRACKETS TO METAL STUD @ 24" INTERVAL USING SHEET METAL SCREWS 5/8" GWB MII -ol NO. REVISION DATE PROJECT TITLE /OWNER SAHAL CAFE/ BARBER 13919 TUKWILA INT'L BLVD. TUKWILA, WA 98168 CONTACT: ANIS A MED 206) 334 -3424 TYPE I HOOD NW ARCHITECTURE A R C H I T E C T U R E 3828 4TH AVE. S. SEATTLE, WA 98134 206.355.9686 REGISTRATION 8171 REGISTERED ARCHITECT UNG T. SKIM TATE OF WASHINGTON NWA PROJECT NO. 301 -188 1_ cr) DRAWN BY -- CHK BY YK DATE 01/31/2011 SCALE AS NOTED TITLE PROJECT INFO., MAP, NOTES, DTLS NUMBER MH1.1 ALL COPY RIGHT RIGHTS RESERVED,