HomeMy WebLinkAboutPermit M11-094 - CITY OF TUKWILA - 6300 BUILDING SERVER ROOMCITY OF TUKWILA
SERVER ROOM
6300 SOUThCENTER BL
M11-094
City olkukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 0003200005
Address: 6300 SOUTHCENTER BL TUKW
Project Name: CITY OF TUKWILA SERVER ROOM
Permit Number: M11 -094
Issue Date: 07/14/2011
Permit Expires On: 01/10/2012
Owner:
Name: TUKWILA CITY OF
Address: 6200 SOUTHCENTER BLVD , TUKWILA WA 98188
Contact Person:
Name: MICHAEL ATWOOD
Address: 9630 153 AV NE , REDMOND WA 98052
Email: matwood @meritmechanical.com
Contractor:
Name: MERIT MECHANICAL INC.
Address: PO BOX 2109 , REDMOND, WA 98052
Contractor License No: MERITMI163CM
Phone: 425 883 -9224
Phone: 425 883 -9224
Expiration Date: 06/01/2013
DESCRIPTION OF WORK:
REPLACE ONE EXISTING HEAT PUMP AND AIR HANDLER WITH NEW FOR SERVER ROOM COOLING.
Value of Mechanical: $9,279.00
Type of Fire Protection: SPRINKLERS /AFA
Electrical Service Provided by:
Permit Center Authorized Signature:
Fees Collected:
$306.06
International Mechanical Code Edition: 2009
Date: C")%,0/
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Print Name: I'tICOW
Date: Viy/u
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M11 -094 Printed: 07 -14 -2011
PERMIT CONDITIONS
Permit No. M11 -094
1: ** *BUILDING DEPARTMENT CONDITIONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206- 431- 3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206- 431 - 3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M11 -094 Printed: 07 -14 -2011
CITY OF TUKV[ A
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http.71www.ci.tukwila.wa.us
Mechanical Permit No.
Project No.
MU-o91
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
Site Address: 6300 Southcenter Blvd
Tenant Name: City of Tukwila Server Room
King Co Assessor's Tax No.: 0(X)320 GOO S
Suite Number: Floor:
New Tenant: ❑ Yes 0.. No
Property Owners Name: City of Tukwila
Mailing Address:
City
State
Zip
CONTACT PERSON — who 4
cot
tact when your pei
eady to be issued
Name: Michael Atwood
Mailing Address: 9630 153rd Ave NE
Day Telephone: (425) 883 -9224
Redmond WA
98052
E -Mail Address: matwood @meritmechanical.com
City State
Fax Number: (425) 867 -0962
Zip
MECHANICAL CONTRACTOR INFORMATION
Company Name: Merit Mechanical, Inc.
Mailing Address: 9630 153rd Ave NE
Contact Person: Same as Above
WA
98052
E -Mail Address:
Contractor Registration Number: I I(.3 cyttl
City
Day Telephone:
Fax Number:
Expiration Date: OC(o C /z, l-3
State
Zip
ARCHITECT OF RECORD — Al
p1
be stamped by architec
of record
Company Name:
Mailing Address:
City
Contact Person: Day Telephone:
Fax Number:
State
Zip
E -Mail Address:
ENGINEER OF RECORD - All plans must be stamped by engineer of record
Company Name:
Mailing Address:
Zip
City
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
State
H. \Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Application.doc
Revised: 7 -2010
bh
Page 1 of 2
Valuation of project (contractor's bid price): $ 9,279.00
Scope of work (please provide detailed information): Replace one existing Heat Pump and Air handler with new for
Server room cooling.
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement m
Fuel Type: Electric m Gas
Other:
Indicate type of mechanical work being installed and the quanf ty below:
Unit Type:
Qty
Unit Type:
Qty
Unit Type:
Qty
Bigler /Compressor
Qty
furnace <100k btu
air handling unit
>10,000 cfm
fire damper
0 -3 hp /100,000 btu
1
furnace >100k btu
evaporator cooler
diffuser
3 -15 hp /500,000 btu
floor furnace
ventilation fan connected
to single duct
thermostat
15 -30 hp /1,000,000
btu
suspended/wall/floor
mounted heater
ventilation system
wood/gas stove
30 -50 hp /1,750,000
btu
appliance vent
hood and duct
emergency
generator
50+ hp /1,750,000 btu
repair or addition to
heat/refrig/cooling system
Incinerator — domestic
other mechanical
equipment
air handling unit <10,000
cfm
1
incinerator — comm /ind
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 international building code (current edition).
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDIN OWNER 0 ` UTHORIZED AGE
Signature:
Date:
1-k/zi, 41
Print Name: Michael Atwood Day Telephone: (425) 883 -9224
Mailing Address: 9630 153rd Ave NE Redmond WA 98052
State Zip
IDate Application Accepted: 4111
City
Date Application Expires:
QI
In6
1-1 \Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Application doc
Revised' 7 -2010
hh
Staff Initials: a
Page 2 of 2
CAPy of Tukwila,
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206-431-3665
Web site: http: //www. ci. tukwila. wa. us
SET RECEIPT
Copy Reprinted on 07 -08 -2011 at 12:02:02 07/08/2011
RECEIPT NO: R11 -01403
Initials: JEM
Payment Date: 07/08/2011
User ID: 1165 Total Payment: 377.46
Payee: MERIT MECHANICAL, INC.
SET ID: S000001527 SET NAME: Temporary Set
SET TRANSACTIONS:
Set Member
EL11 -0603
M11 -094
TOTAL:
Amount
71.40
306.06
71.40
TRANSACTION LIST:
Type Method Description
Amount
Payment Check 24488 377.46
TOTAL: 377.46
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
ELECTRICAL PERMIT - NONR
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.101.00.0
000.322.102.00.0
000.345.830
71.40
244.85
61.21
TOTAL: 377.46
" .
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project: . ____
(7, /.// "71 77/ati/Z 4
Type of Inspection:
,c-//049 /
Address:
14.C.
Date Called:
Special Instructions:
Date Wanted:
Requester:
Phone No:
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Pe,(04;4
1
1
44P 7;----ItAlot
Date:
REI SPECTION FEE REQUIR D. Prior to ext inspection. fee must be .
p d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
•
•
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
/14/1- 69/.
PERMIT'NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670
Project: _
(I, f` if ,),+rw,/,r
Type of InspeStion: -
/ ?J'`h 0 —,K/
Address:
Gdoc.) S s /toe a,Ok..
,x
/
Date Called:
Special Instructions:
Date Wanted:
Requester:
Phone No:
f2Approved per applicable codes. LJ Corrections required prior to approval. /c
COMMENTS:
/?tn f h - ;.,
4/),/,v•,0
eV,- s..,.0.J...7.) / . 61--- 4/ p.e.4
t
Date:
(A.44.A.4 / 1 ., " „ ./ c.� -2 - i 3- / -
REINSPECTION EE REQUIRED. Prior to inspection. f e must be
at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection.
Rec•'.t No.:
Date:
_ :.v..A. ;,G : i :_... _.:!:.s- :.: •x:.y n. b_'M -..s y�.:':2?' ;:e mn..-�a''.' !.;i. �:s_ .._L)
iPERMIT COORD COPY
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M11 -094 DATE: 07/08/11
PROJECT NAME: CITY OF TUWILA — SERVER ROOM
SITE ADDRESS: 6300 SOUTHCENTER BL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
Bing Division
Public Works
NkP bl
Fire Prevention
Structural
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete n
DUE DATE: 07/12/11
Not Applicable
n
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
Structural Review Required
No further Review Required I N
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 08/09/11
Approved ❑ Approved with Conditions 11 Not Approved (attach comments)
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents /routing slip.doc
2 -28 -02
Contractors or Tradespeople Pf ter Friendly Page
1
General /Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name MERIT MECHANICAL INC UBI No. 600517946
Phone 4258839224 Status Active
Address 9630 153Rd Avenue Ne License No. MERITMI163CM
Suite /Apt. License Type Construction Contractor
City Redmond Effective Date 2/14/1984
State WA Expiration Date 6/1/2013
Zip 98052 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
AUTOMMC044QH
AUTOMATED MECH
CONTROLS INC
Construction
Contractor
General
Unused
11/8/1996
6/1/2010
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
KIRKWOOD, RODERICK V
President
02/14/1984
Bond Amount
KIRKWOOD, JOAN M
Secretary
02/27/2006
08358695
FRICKBERG, WILLIAM MICHAEL
Vice President
02/27/2006
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
10
FIDELITY & DEPOSIT
CO OF MD
08358695
02/01/2010
Until Cancelled
$12,000.0001/20
/2010
9
ARCH INS CO
SU1041124
02/01/2009
Until Cancelled
02/01/2010
$12,000.0001/12
/2009
8
TRAVELERS CAS &
SURETY CO
081S103546895BCM
07/22/2001
Until Cancelled
02/01/2009
$12,000.0003/07
/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
26
LEXINGTON I INS
014180670
11/01/2010
11/01/2011
$2,000,000.0010
/29/2010
25
LEXINGTON I INS
049159165
11/01/2009
11/01/2010
$2,000,000.00
11/02/2009
24
LEXINGTON I INS
004052434
11/01/2008
11/01/2009
$2,000,000.0011
/04/2008
23
ACE AMERICAN
1100623734941
03/03/2008
03/03/2009
$2,000,000.0003
/10/2008
22
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2007
11/01/2008
$1,000,000.0010
/31/2007
21
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2005
11/01/2007
$1,000,000.0010
/18/2006
20
CONTINENTAL
WESTERN INS
CO
CWP2545786
11/01/2004
11/01/2005
$1,000,000.0011
/01/2004
https://fortress.wa.gov/lni/bbip/Print.aspx
07/14/2011
HEAT PUMP UNIT SCHEDULE
TAG
MAKE Sc MODEL
DESCRIPTION
SERVING
COOLING, MBH
HEATING, MBH
REGRIG. PIPE
OUTDOOR FAN
SOUND
COMPRESSOR
ELECTRICAL
WEIGHT
REMARKS
TOTAL
SEER
TOTAL
HSPF
LIQ.
SUCT.
FLA
DRIVE
dBA
TYPE
VOLT
PH
MCA
MOCP
LBS
HP -1
FUJITSU AOU3ORLX 2.5 TON
HEAT PUMP UNIT
SERVER ROOM
30.6
17.5
32
9.5
3/8
5/8
—
DIRECT
55
-
208/230
1
13.1
30
137
1, 2
NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER.
2. LOW /HI PRESS SWITCH, CRANKCASE HEATER, LOW AMBIENT.
AIR HANDLER SCHEDULE
TAG
MAKE & MODEL
DESCRIPTION
SERVING
FAN
ELECTRICAL
WEIGHT
REMARKS
CFM
ESP
RPM
FLA
VOLT
PH
MCA
MOCP
LBS
AH -1
FUJITSU ASU3ORLX
DUCTLESS AIR HANDLER
SERVER ROOM
660
—
HI
—
208/230
1
—
—
31
1, 2
NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER.
2. INDOOR UNIT POWER BY OUTDOOR UNIT.
EXISTING HEAT PUMP UNIT SCHEDULE
TAG
MAKE & MODEL
DESCRIPTION
SERVING
ELECTRICAL
WEIGHT
REMARKS
VOLT
PH
MCA
MOCP
LBS
HP -1
MITSUBISHI PUYA3ONHA 2.5 TON
HEAT PUMP UNIT
SERVER ROOM
208/230
1
—
—
163
EXISTING AIR HANDLER SCHEDULE
TAG
MAKE & MODEL
DESCRIPTION
SERVING
ELECTRICAL
WEIGHT
REMARKS
VOLT
PH
MCA
MOCP
LBS
AH -1
MITSUBISHI PKAA30FA
DUCTLESS AIR HANDLER
SERVER ROOM
208/230
1
—
-
46
GENERAL NOTES
1. FIELD VERIFY UNIT LOCATIONS, DROPS, AND POSITIONS.
2. ALL LINE VOLTAGE BY ELECTRICIAN.
3. 3/4" PVC CONDENSATE DRAIN WITH TRAP. USE COPPER PIPING FOR ABOVE HARD LID CEILING
4. PROJECT MANAGER TO VERIFY LENGTH OF REFRIGERATION PIPING FOR LINE SIZES AND TRAPS AS PER
MANUFACTURERS REQUIREMENTS.
5. HVAC SYSTEM IS DESIGNED PER 2009 WSEC, IBC, AND IMC.
T
N
M
35-1/2"X14-1/4" —►{
L.
DIMENSIONS FOR HP -1
SCALE: NONE
FILE COPY
Penult No.
Flan review apparel is
Approval of cones. documents
the violation of any adopted code or
of aplpro and
\IV
BY
and omission
s not autheriz3
rdinance. Receipt
is acknowledged:
City Of
BUILDING D
11
SION
LAND SCAPE
39 1/2 "X9 "�
DIMENSIONS FOR AH -1
SCALE: NONE
87' -3"
SCOPE OF WORK
1. REPLACE 1 EXISTING SPLIT SYSTEM HEAT PUMP UNIT WITH NEW.
2. REPLACE 1 EXISTING SPLIT SYSTEM DUCTLESS AIR HANDLER UNIT
WITH NEW.
130' -10"
80' -1"
VICINITY MAP
0)
1
141' -0"
LEGAL DESCRIPTION
GILLIAM W H —D C #40 POR DONATION CLAIM IN S 1/2 OF SE
1/4 OF SEC 23 -23 -04 DAF — BEG 1836.78 FT W & 1501.50
FT N OF COR OF SEC 23, 24, 25 & 26 TH E 350 FT TO TPOB
TH E 150 FT TH S 460.15 FT M/L TO NLY MGN OF CO RD NO
622 TH WLY ALG SD RD TAP S OF TPOB TH N TO TPOB
TAX PARCEL NUMBER: 000320 -0005
BUILDING INFORMATION
ZONING:
CONSTRUCTION TYPE:
OCCUPANCY TYPE:
0
MASONRY (SPRINKLERS)
OFFICE
REVISIONS
No changes shaft bo made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions win require a new plan submittal
and may include additional plan review fees.
OWNER
CITY OF TUKWILA
SEPARATE PERMIT
REQUIRED FOR:
Mechanical
Electrical
!numbing
Gas Piping
City of Tukwila
BUILDING DIVISION
SITE PLAN
SCALE: 1/32" = 1' -
11
COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS
RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS
OF THE DATE OF SYSTEM ACCEPTANCE PER WASH. STATE ENERGEY CODE (WSEC) SECTION 1416.1 (2006 EDITION)
AN OPERATION MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC
SECTION 1416.2.4.2 (2006 EDITION)
ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER
PER WSEC SECTION 1416.2.2. (2006 EDITION)
HVAC CONTROL SYSTEM SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE
TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND COMPLETE
REPORT OF TEST RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2 AND 1416.2.5.
(2006 EDITION)
ABBREVIATIONS
ABV. ABOVE
A.D. ACCESS DOOR
A.P. ACCESS PANEL
A.F.F. ABOVE FINISHED FLOOR
Al AIR HANDLING UNIT
BF BELOW FLOOR
EFC BELOW FINISHED CEILING
BOT BOTTOM
GIP CAST IN PLACE
CLG CEILING
CD CEILING DIFFUSER
CG CEILING GRILLE
CTG CEILING TRANSFER GRILLE
CONC. CONCRETE
CONN. CONNECTION
CFM CUBIC FEET PER MINUTE
DIFF. DIFFUSER
DIA. DIAMETER
DN DOWN
DWG. DRAWING
DB DRY BULB
EA. EACH
ENT. ENTERING
EAT ENTERING AIR TEMPERATURE
EWT ENTERING WATER TEMPERATURE
EQUIP EQUIPMENT
EXH EXHAUST
I_SP EXTERNAL STATIC PRESSURE
FLR FLOOR
F. FOOT or FEET
FPM FEET PER MINUTE
FUT. FUTURE
GALV. GALVANIZE
CR. GRILLE
HWG HIGH WALL GRILLE
IWTG HIGH WALL TRANSFER GRILLE
HT. HEIGHT
HP" HORSEPOWER
HWS HOT WATER SUPPLY
HWR HOT WATER RETURN
ID INSIDE DIAMETER /DIMENSION
IE INVERT ELEVATION
IN. WG INCHES W.G.
LIN. DIFF. LINEAR DIFFUSER
LIN. FT. LINEAR FEET /FOOT
LWG LOW WALL GRILLE
LWR LOW WALL REGISTER
MAX. MAXIMUM
MBH 1000 BRITISH THERMAL UNITS
MIN. MINIMUM
MOT. DPR. MOTORIZED DAMPER
MTD MOUNTED
N.C. NORMALLY CLOSED
N.O. NORMALLY OPEN
OSA OUTSIDE AIR
OBD OPPOSED BLADE DAMPER
OD OUTSIDE DIAMETER /DIMENSION
PCF POUNDS PR CUBIC FOOT
POC POINT OF CONNECTION
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
RPBP REDUCED PRESSURE BACKFLOW PREVENTOR
RFA RELIEF AIR
REG. REGISTER REVIEWED FOR
REQ'D REQUIRED CODE COMPLIANCE
RA RETURN AIR APPROVED
SQ. FT. SQUARE FEET
SA SUPPLY AIR JUL 1 2 2011
S.L. SOUND LINED
TDH TOTAL DYNAMIC -IEAD J ,
TG TRANSFER GRILL City of T !la
TOT T'P TYPIC AL TOTAL BUILDING D `'■ SION
C
VTR VENT THROUGH ROOF
WB WET BULB
WG WATER GAUGE
W/ WITH
W/0 WITHOUT
DUCTWORK LEGEND
m
m
0
0
►01
0
R — 100
S — 100
E — 100
- - -- SLSM
F
SFD
FD
VD
MD
VD t J
MIN 3'
AIR FLOW DIRECTION
SUPPLY OR OSA DUCT SECTION UP OR TOWARD
ROUND, RECTANGULAR
RETURN, RELIEF OR EXHAUST DUCT SECTION UP OR TOWARD
ROUND, RECTANGULAR
SUPPLY OR OSA DUCT SECTION DOWN OR AWAY
ROUND, RECTANGULAR
RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY
ROUND, RECTANGULAR
ROUND DUCT SYMBOL
RETURN AIR; NUMBER INDICATES CFM QUANTITY
SUPPLY AIR; NUMBER INDICATES CFM QUANTITY
EXHAUST AIR; NUMBER INDICATES CFM QUANTITY
SOUND LINED SHEET METAL
FLEXIBLE EQUIPMENT CONNECTION
SMOKE /FIRE DAMPER
FIRE DAMPER
VOLUME DAMPER
MOTORIZED DAMPER
TURNING VANES
ROUND TO ROUND 45' CFA
SQUARE TO SQUARE 45' FITTING
SQUARE TO ROUND 45' FITTING
45' FITTING FOR DUCTWORK
EVIEWEL) FOb
C r PLIANCE • ITH
A70 IEC
JU 72011.
la
ON
GENERAL - LEGEND
0
L _ _J
NEW EQUIPMENT, DUCTWORK, AND GRILLES
EXISTING EQUIPMENT, DUCTWORK, AND GRILLES
DETAIL OR DIAGRAM NUMBER
SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN
SECTION LETTER
SHEET NUMBER WHERE SECTION SHOWN
REVISION CLOUD & CHRONOLOGICAL NUMBER
DETAIL REFERENCE OUTLINE
POINT OF CONNECTION
THERMOSTAT
RECEIV
CITYOFTU LA
JUL 082011
PERMIT CENTER
COPYRIGHT NOTICE
THIS LAYOUT /DESIGN IS AN
UNPUBLISHED WORK, AND
MERIT MECHANICAL HEREBY
RESERVES ITS COMMON LAW
RIGHT, PURSUANT TO TITLE
17 SECTION 2 OF THE USA
CODE TO PREVENT ANY
UNAUTHORIZED COPYING,
PUBLICATION OR USE OF.
THIS DESIGN, AND TO OBTAIN
DAMAGES THEREFORE.
6300 SOUTHCENTER BLVD
TUKWILA WA, 98188
MERIT MECHANICAL INC.
9630 153RD AVENUE NE
P.O. BOX 2109
REDMOND, WA 98073-2109
(425) 883 -9224
FAX (425) 867 -0962
LICENSE: MERITMI163CM
REVISIONS
1. ISSUED FOR PERMIT 07 -08 -11
DESIGNED
VTD
CHECKED
AEA
DATE
07-07-11
JOB NUMBER
811334
SHEET TITLE
HVAC PLAN &
SCHEDULES
SHEET NUMBER
■
1 —OF -2
REFER UP
IT
SERVER
ROOM
CONDENSATE
DOWN
HVAC FLOOR PLAN
SCALE: 1/8" = 1' - 0"
130' -10"
REFER DN
REVIEWED FOR
CODE COMPLIANCE
C�
APP
JUL 12 2011
City of Tukwila
BUILDING DIVISION
rtv
80' -1"
M 11-
0
HVAC ROOF PLAN
SCALE: 1/8" = 1' - 0"
COPYRIGHT NOTICE
THIS LAYOUT /DESIGN IS AN
UNPUBLISHED WORK, AND
MERIT MECHANICAL HEREBY
RESERVES ITS COMMON LAW
RIGHT, PURSUANT TO TITLE
17 SECTION 2 OF THE USA
CODE TO PREVENT ANY
UNAUTHORIZED COPYING,
PUBLICATION OR USE OF
THIS DESIGN, AND TO OBTAIN
DAMAGES THEREFORE.
VIEWED FOR
CO PLIANCE W
N 'A70-
JUL +' 2011
City •f.Tu ila
BUIL NG DIV , IONS
9y
CITY OF TUKWILA
JUL 0 82011
PERMIT CENTER
J <
=
O uJ
pac
V
TUKWILA WA, 98188
MERIT MECHANICAL INC.
9630 153RD AVENUE NE
P.O. BOX 2109
REDMOND, WA 98073 -2109
FAX 4(425) 8867?0962
LICENSE: MERITMI1.63CM
REVISIONS
1. ISSUED FOR PERMIT 07 -08 -11
DESIGNED
VTD
CHECKED
AEA
DATE
07 -07 -11
JOB NUMBER
811334
SHEET TITLE
HVAC ROOF &
FLOOR PLAN
SHEET NUMBER
M2.0
2 -0F -2