HomeMy WebLinkAboutPermit M11-094 - CITY OF TUKWILA - 6300 BUILDING SERVER ROOMCITY OF TUKWILA SERVER ROOM 6300 SOUThCENTER BL M11-094 City olkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0003200005 Address: 6300 SOUTHCENTER BL TUKW Project Name: CITY OF TUKWILA SERVER ROOM Permit Number: M11 -094 Issue Date: 07/14/2011 Permit Expires On: 01/10/2012 Owner: Name: TUKWILA CITY OF Address: 6200 SOUTHCENTER BLVD , TUKWILA WA 98188 Contact Person: Name: MICHAEL ATWOOD Address: 9630 153 AV NE , REDMOND WA 98052 Email: matwood @meritmechanical.com Contractor: Name: MERIT MECHANICAL INC. Address: PO BOX 2109 , REDMOND, WA 98052 Contractor License No: MERITMI163CM Phone: 425 883 -9224 Phone: 425 883 -9224 Expiration Date: 06/01/2013 DESCRIPTION OF WORK: REPLACE ONE EXISTING HEAT PUMP AND AIR HANDLER WITH NEW FOR SERVER ROOM COOLING. Value of Mechanical: $9,279.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $306.06 International Mechanical Code Edition: 2009 Date: C")%,0/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: I'tICOW Date: Viy/u This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M11 -094 Printed: 07 -14 -2011 PERMIT CONDITIONS Permit No. M11 -094 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431- 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M11 -094 Printed: 07 -14 -2011 CITY OF TUKV[ A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http.71www.ci.tukwila.wa.us Mechanical Permit No. Project No. MU-o91 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: 6300 Southcenter Blvd Tenant Name: City of Tukwila Server Room King Co Assessor's Tax No.: 0(X)320 GOO S Suite Number: Floor: New Tenant: ❑ Yes 0.. No Property Owners Name: City of Tukwila Mailing Address: City State Zip CONTACT PERSON — who 4 cot tact when your pei eady to be issued Name: Michael Atwood Mailing Address: 9630 153rd Ave NE Day Telephone: (425) 883 -9224 Redmond WA 98052 E -Mail Address: matwood @meritmechanical.com City State Fax Number: (425) 867 -0962 Zip MECHANICAL CONTRACTOR INFORMATION Company Name: Merit Mechanical, Inc. Mailing Address: 9630 153rd Ave NE Contact Person: Same as Above WA 98052 E -Mail Address: Contractor Registration Number: I I(.3 cyttl City Day Telephone: Fax Number: Expiration Date: OC(o C /z, l-3 State Zip ARCHITECT OF RECORD — Al p1 be stamped by architec of record Company Name: Mailing Address: City Contact Person: Day Telephone: Fax Number: State Zip E -Mail Address: ENGINEER OF RECORD - All plans must be stamped by engineer of record Company Name: Mailing Address: Zip City Contact Person: Day Telephone: E -Mail Address: Fax Number: State H. \Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Application.doc Revised: 7 -2010 bh Page 1 of 2 Valuation of project (contractor's bid price): $ 9,279.00 Scope of work (please provide detailed information): Replace one existing Heat Pump and Air handler with new for Server room cooling. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement m Fuel Type: Electric m Gas Other: Indicate type of mechanical work being installed and the quanf ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bigler /Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0 -3 hp /100,000 btu 1 furnace >100k btu evaporator cooler diffuser 3 -15 hp /500,000 btu floor furnace ventilation fan connected to single duct thermostat 15 -30 hp /1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30 -50 hp /1,750,000 btu appliance vent hood and duct emergency generator 50+ hp /1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment air handling unit <10,000 cfm 1 incinerator — comm /ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OWNER 0 ` UTHORIZED AGE Signature: Date: 1-k/zi, 41 Print Name: Michael Atwood Day Telephone: (425) 883 -9224 Mailing Address: 9630 153rd Ave NE Redmond WA 98052 State Zip IDate Application Accepted: 4111 City Date Application Expires: QI In6 1-1 \Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Mechanical Permit Application doc Revised' 7 -2010 hh Staff Initials: a Page 2 of 2 CAPy of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www. ci. tukwila. wa. us SET RECEIPT Copy Reprinted on 07 -08 -2011 at 12:02:02 07/08/2011 RECEIPT NO: R11 -01403 Initials: JEM Payment Date: 07/08/2011 User ID: 1165 Total Payment: 377.46 Payee: MERIT MECHANICAL, INC. SET ID: S000001527 SET NAME: Temporary Set SET TRANSACTIONS: Set Member EL11 -0603 M11 -094 TOTAL: Amount 71.40 306.06 71.40 TRANSACTION LIST: Type Method Description Amount Payment Check 24488 377.46 TOTAL: 377.46 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 000.322.102.00.0 000.345.830 71.40 244.85 61.21 TOTAL: 377.46 " . INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: . ____ (7, /.// "71 77/ati/Z 4 Type of Inspection: ,c-//049 / Address: 14.C. Date Called: Special Instructions: Date Wanted: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pe,(04;4 1 1 44P 7;----ItAlot Date: REI SPECTION FEE REQUIR D. Prior to ext inspection. fee must be . p d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • • INSPECTION NO. INSPECTION RECORD Retain a copy with permit /14/1- 69/. PERMIT'NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Project: _ (I, f` if ,),+rw,/,r Type of InspeStion: - / ?J'`h 0 —,K/ Address: Gdoc.) S s /toe a,Ok.. ,x / Date Called: Special Instructions: Date Wanted: Requester: Phone No: f2Approved per applicable codes. LJ Corrections required prior to approval. /c COMMENTS: /?tn f h - ;., 4/),/,v•,0 eV,- s..,.0.J...7.) / . 61--- 4/ p.e.4 t Date: (A.44.A.4 / 1 ., " „ ./ c.� -2 - i 3- / - REINSPECTION EE REQUIRED. Prior to inspection. f e must be at 6300 Southcenter Blvd.. Suite 100. Call the schedule reinspection. Rec•'.t No.: Date: _ :.v..A. ;,G : i :_... _.:!:.s- :.: •x:.y n. b_'M -..s y�.:':2?' ;:e mn..-�a''.' !.;i. �:s_ .._L) iPERMIT COORD COPY PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M11 -094 DATE: 07/08/11 PROJECT NAME: CITY OF TUWILA — SERVER ROOM SITE ADDRESS: 6300 SOUTHCENTER BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Bing Division Public Works NkP bl Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07/12/11 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required I N REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/09/11 Approved ❑ Approved with Conditions 11 Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pf ter Friendly Page 1 General /Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MERIT MECHANICAL INC UBI No. 600517946 Phone 4258839224 Status Active Address 9630 153Rd Avenue Ne License No. MERITMI163CM Suite /Apt. License Type Construction Contractor City Redmond Effective Date 2/14/1984 State WA Expiration Date 6/1/2013 Zip 98052 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUTOMMC044QH AUTOMATED MECH CONTROLS INC Construction Contractor General Unused 11/8/1996 6/1/2010 Expired Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V President 02/14/1984 Bond Amount KIRKWOOD, JOAN M Secretary 02/27/2006 08358695 FRICKBERG, WILLIAM MICHAEL Vice President 02/27/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 FIDELITY & DEPOSIT CO OF MD 08358695 02/01/2010 Until Cancelled $12,000.0001/20 /2010 9 ARCH INS CO SU1041124 02/01/2009 Until Cancelled 02/01/2010 $12,000.0001/12 /2009 8 TRAVELERS CAS & SURETY CO 081S103546895BCM 07/22/2001 Until Cancelled 02/01/2009 $12,000.0003/07 /2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 LEXINGTON I INS 014180670 11/01/2010 11/01/2011 $2,000,000.0010 /29/2010 25 LEXINGTON I INS 049159165 11/01/2009 11/01/2010 $2,000,000.00 11/02/2009 24 LEXINGTON I INS 004052434 11/01/2008 11/01/2009 $2,000,000.0011 /04/2008 23 ACE AMERICAN 1100623734941 03/03/2008 03/03/2009 $2,000,000.0003 /10/2008 22 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2007 11/01/2008 $1,000,000.0010 /31/2007 21 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2005 11/01/2007 $1,000,000.0010 /18/2006 20 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2004 11/01/2005 $1,000,000.0011 /01/2004 https://fortress.wa.gov/lni/bbip/Print.aspx 07/14/2011 HEAT PUMP UNIT SCHEDULE TAG MAKE Sc MODEL DESCRIPTION SERVING COOLING, MBH HEATING, MBH REGRIG. PIPE OUTDOOR FAN SOUND COMPRESSOR ELECTRICAL WEIGHT REMARKS TOTAL SEER TOTAL HSPF LIQ. SUCT. FLA DRIVE dBA TYPE VOLT PH MCA MOCP LBS HP -1 FUJITSU AOU3ORLX 2.5 TON HEAT PUMP UNIT SERVER ROOM 30.6 17.5 32 9.5 3/8 5/8 — DIRECT 55 - 208/230 1 13.1 30 137 1, 2 NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER. 2. LOW /HI PRESS SWITCH, CRANKCASE HEATER, LOW AMBIENT. AIR HANDLER SCHEDULE TAG MAKE & MODEL DESCRIPTION SERVING FAN ELECTRICAL WEIGHT REMARKS CFM ESP RPM FLA VOLT PH MCA MOCP LBS AH -1 FUJITSU ASU3ORLX DUCTLESS AIR HANDLER SERVER ROOM 660 — HI — 208/230 1 — — 31 1, 2 NOTES: 1. EQUIPMENT MAY BE SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER. 2. INDOOR UNIT POWER BY OUTDOOR UNIT. EXISTING HEAT PUMP UNIT SCHEDULE TAG MAKE & MODEL DESCRIPTION SERVING ELECTRICAL WEIGHT REMARKS VOLT PH MCA MOCP LBS HP -1 MITSUBISHI PUYA3ONHA 2.5 TON HEAT PUMP UNIT SERVER ROOM 208/230 1 — — 163 EXISTING AIR HANDLER SCHEDULE TAG MAKE & MODEL DESCRIPTION SERVING ELECTRICAL WEIGHT REMARKS VOLT PH MCA MOCP LBS AH -1 MITSUBISHI PKAA30FA DUCTLESS AIR HANDLER SERVER ROOM 208/230 1 — - 46 GENERAL NOTES 1. FIELD VERIFY UNIT LOCATIONS, DROPS, AND POSITIONS. 2. ALL LINE VOLTAGE BY ELECTRICIAN. 3. 3/4" PVC CONDENSATE DRAIN WITH TRAP. USE COPPER PIPING FOR ABOVE HARD LID CEILING 4. PROJECT MANAGER TO VERIFY LENGTH OF REFRIGERATION PIPING FOR LINE SIZES AND TRAPS AS PER MANUFACTURERS REQUIREMENTS. 5. HVAC SYSTEM IS DESIGNED PER 2009 WSEC, IBC, AND IMC. T N M 35-1/2"X14-1/4" —►{ L. DIMENSIONS FOR HP -1 SCALE: NONE FILE COPY Penult No. Flan review apparel is Approval of cones. documents the violation of any adopted code or of aplpro and \IV BY and omission s not autheriz3 rdinance. Receipt is acknowledged: City Of BUILDING D 11 SION LAND SCAPE 39 1/2 "X9 "� DIMENSIONS FOR AH -1 SCALE: NONE 87' -3" SCOPE OF WORK 1. REPLACE 1 EXISTING SPLIT SYSTEM HEAT PUMP UNIT WITH NEW. 2. REPLACE 1 EXISTING SPLIT SYSTEM DUCTLESS AIR HANDLER UNIT WITH NEW. 130' -10" 80' -1" VICINITY MAP 0) 1 141' -0" LEGAL DESCRIPTION GILLIAM W H —D C #40 POR DONATION CLAIM IN S 1/2 OF SE 1/4 OF SEC 23 -23 -04 DAF — BEG 1836.78 FT W & 1501.50 FT N OF COR OF SEC 23, 24, 25 & 26 TH E 350 FT TO TPOB TH E 150 FT TH S 460.15 FT M/L TO NLY MGN OF CO RD NO 622 TH WLY ALG SD RD TAP S OF TPOB TH N TO TPOB TAX PARCEL NUMBER: 000320 -0005 BUILDING INFORMATION ZONING: CONSTRUCTION TYPE: OCCUPANCY TYPE: 0 MASONRY (SPRINKLERS) OFFICE REVISIONS No changes shaft bo made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions win require a new plan submittal and may include additional plan review fees. OWNER CITY OF TUKWILA SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical !numbing Gas Piping City of Tukwila BUILDING DIVISION SITE PLAN SCALE: 1/32" = 1' - 11 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WASH. STATE ENERGEY CODE (WSEC) SECTION 1416.1 (2006 EDITION) AN OPERATION MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.2.4.2 (2006 EDITION) ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 1416.2.2. (2006 EDITION) HVAC CONTROL SYSTEM SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND COMPLETE REPORT OF TEST RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.2.3.2 AND 1416.2.5. (2006 EDITION) ABBREVIATIONS ABV. ABOVE A.D. ACCESS DOOR A.P. ACCESS PANEL A.F.F. ABOVE FINISHED FLOOR Al AIR HANDLING UNIT BF BELOW FLOOR EFC BELOW FINISHED CEILING BOT BOTTOM GIP CAST IN PLACE CLG CEILING CD CEILING DIFFUSER CG CEILING GRILLE CTG CEILING TRANSFER GRILLE CONC. CONCRETE CONN. CONNECTION CFM CUBIC FEET PER MINUTE DIFF. DIFFUSER DIA. DIAMETER DN DOWN DWG. DRAWING DB DRY BULB EA. EACH ENT. ENTERING EAT ENTERING AIR TEMPERATURE EWT ENTERING WATER TEMPERATURE EQUIP EQUIPMENT EXH EXHAUST I_SP EXTERNAL STATIC PRESSURE FLR FLOOR F. FOOT or FEET FPM FEET PER MINUTE FUT. FUTURE GALV. GALVANIZE CR. GRILLE HWG HIGH WALL GRILLE IWTG HIGH WALL TRANSFER GRILLE HT. HEIGHT HP" HORSEPOWER HWS HOT WATER SUPPLY HWR HOT WATER RETURN ID INSIDE DIAMETER /DIMENSION IE INVERT ELEVATION IN. WG INCHES W.G. LIN. DIFF. LINEAR DIFFUSER LIN. FT. LINEAR FEET /FOOT LWG LOW WALL GRILLE LWR LOW WALL REGISTER MAX. MAXIMUM MBH 1000 BRITISH THERMAL UNITS MIN. MINIMUM MOT. DPR. MOTORIZED DAMPER MTD MOUNTED N.C. NORMALLY CLOSED N.O. NORMALLY OPEN OSA OUTSIDE AIR OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMETER /DIMENSION PCF POUNDS PR CUBIC FOOT POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE RPBP REDUCED PRESSURE BACKFLOW PREVENTOR RFA RELIEF AIR REG. REGISTER REVIEWED FOR REQ'D REQUIRED CODE COMPLIANCE RA RETURN AIR APPROVED SQ. FT. SQUARE FEET SA SUPPLY AIR JUL 1 2 2011 S.L. SOUND LINED TDH TOTAL DYNAMIC -IEAD J , TG TRANSFER GRILL City of T !la TOT T'P TYPIC AL TOTAL BUILDING D `'■ SION C VTR VENT THROUGH ROOF WB WET BULB WG WATER GAUGE W/ WITH W/0 WITHOUT DUCTWORK LEGEND m m 0 0 ►01 0 R — 100 S — 100 E — 100 - - -- SLSM F SFD FD VD MD VD t J MIN 3' AIR FLOW DIRECTION SUPPLY OR OSA DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR ROUND DUCT SYMBOL RETURN AIR; NUMBER INDICATES CFM QUANTITY SUPPLY AIR; NUMBER INDICATES CFM QUANTITY EXHAUST AIR; NUMBER INDICATES CFM QUANTITY SOUND LINED SHEET METAL FLEXIBLE EQUIPMENT CONNECTION SMOKE /FIRE DAMPER FIRE DAMPER VOLUME DAMPER MOTORIZED DAMPER TURNING VANES ROUND TO ROUND 45' CFA SQUARE TO SQUARE 45' FITTING SQUARE TO ROUND 45' FITTING 45' FITTING FOR DUCTWORK EVIEWEL) FOb C r PLIANCE • ITH A70 IEC JU 72011. la ON GENERAL - LEGEND 0 L _ _J NEW EQUIPMENT, DUCTWORK, AND GRILLES EXISTING EQUIPMENT, DUCTWORK, AND GRILLES DETAIL OR DIAGRAM NUMBER SHEET NUMBER WHERE DETAIL /DIAGRAM SHOWN SECTION LETTER SHEET NUMBER WHERE SECTION SHOWN REVISION CLOUD & CHRONOLOGICAL NUMBER DETAIL REFERENCE OUTLINE POINT OF CONNECTION THERMOSTAT RECEIV CITYOFTU LA JUL 082011 PERMIT CENTER COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF. THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. 6300 SOUTHCENTER BLVD TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073-2109 (425) 883 -9224 FAX (425) 867 -0962 LICENSE: MERITMI163CM REVISIONS 1. ISSUED FOR PERMIT 07 -08 -11 DESIGNED VTD CHECKED AEA DATE 07-07-11 JOB NUMBER 811334 SHEET TITLE HVAC PLAN & SCHEDULES SHEET NUMBER ■ 1 —OF -2 REFER UP IT SERVER ROOM CONDENSATE DOWN HVAC FLOOR PLAN SCALE: 1/8" = 1' - 0" 130' -10" REFER DN REVIEWED FOR CODE COMPLIANCE C� APP JUL 12 2011 City of Tukwila BUILDING DIVISION rtv 80' -1" M 11- 0 HVAC ROOF PLAN SCALE: 1/8" = 1' - 0" COPYRIGHT NOTICE THIS LAYOUT /DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. VIEWED FOR CO PLIANCE W N 'A70- JUL +' 2011 City •f.Tu ila BUIL NG DIV , IONS 9y CITY OF TUKWILA JUL 0 82011 PERMIT CENTER J < = O uJ pac V TUKWILA WA, 98188 MERIT MECHANICAL INC. 9630 153RD AVENUE NE P.O. BOX 2109 REDMOND, WA 98073 -2109 FAX 4(425) 8867?0962 LICENSE: MERITMI1.63CM REVISIONS 1. ISSUED FOR PERMIT 07 -08 -11 DESIGNED VTD CHECKED AEA DATE 07 -07 -11 JOB NUMBER 811334 SHEET TITLE HVAC ROOF & FLOOR PLAN SHEET NUMBER M2.0 2 -0F -2