HomeMy WebLinkAboutPermit M11-167 - BOEING #14-01BOEING #14-01
8701 EAST MARGINAL WY S
EXPIRED 05 -27 -12
Mi 1 -167
City olliI'ukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 -431 -3670
Inspection Request Line: 206 - 431 -2451
Web site: http: / /www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 0007400033
Address: 8701 EAST MARGINAL WY S TUKW
Project Name: BOEING 14 -01
Permit Number: M11 -167
Issue Date: 11/29/2011
Permit Expires On: OS/27/2012
Owner:
Name: BOEING COMPANY THE
Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124
Contact Person:
Name:
Address:
Email:
CONNIE HARDIN
4600 S 134 PL , SEATTLE WA 98168
C ONNIEH @HO LADAYPARKS. C OM
Contractor:
Name: HOLADAY PARKS, INC.
Address: PO BOX 69208 , SEATTLE, WA 98188
Contractor License No: HOLADPI379NO
Phone: 206 - 250 -4530
Phone: 206 248 -9700
Expiration Date: 09/03/2013
DESCRIPTION OF WORK:
DUCTWORK & DIFFUSERS FOR EXISTING AIR HANDLER.
Value of Mechanical: $70,000.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
x.
with,
r
n5
Fees Collected: $1,002.06
International Mechanical Code Edition: 2009
Date:
ed this permit and know the same to be true and correct. All provisions of law and ordinances
whether specified herein or not.
The granting of this permit does not pr u ' e to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Print Name: 0 ✓ -
Date: k ` 1
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
doc: IMC -4/10
M11 -167 Printed: 11 -29 -2011
• 411
PERMIT CONDITIONS
Permit No. M11 -167
1: ** *BUILDING DEPARTMENT CONDfl IONS * **
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431- 3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M11 -167 Printed: 11 -29 -2011
q3307
thie
•
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
•
Mechanical Permit No. Mil— /F f (, 7
Project No. j r
Date Application Accepted: / / / /f' %f/
Date ApplicationExpires: G'j f/ef %a--
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
* *please print **
SITE LOCATION
Site Address: 'g Q7 O i f f1
Tenant Name: Out: NO 1
King Co Assessor's Tax No.: 00(' l4 oW g3
So
Suite Number: Floor:
New Tenant: ❑ Yes IKNo
PROPERTY OWNER
Name: .
\LOA, Ave
` 1 `
Name: •
ne,L R
S 131 P..-12
City: L k..(4,z_
State:, /� Zip: �tl C
�J
Address: 9.0 6
37D7
Email:
(°-frikn,:e,1A
0 \a. (a-A.c- c .c....ow(
City: JeQ A
State: �0—
Zip:
lay
CONTACT, PERSON — person receiving all project
communication
Name: .
\LOA, Ave
` 1 `
Address: 4 l000
S 131 P..-12
City: L k..(4,z_
State:, /� Zip: �tl C
�J
Phone:
b-,)-S
Fax:
S30 ;-o(0- D46-i?ud
Email:
(°-frikn,:e,1A
0 \a. (a-A.c- c .c....ow(
MECHANICAL C O__ NTRACTOR INFORMATION
Company Name:
Address: , I o()I) \Loi....._ p_ n
City: Z a State: Zy67i / f c
X1-171
PhoneZ / l0 )- L1 S3 /-- F 71)i
Contr Reg /
No !tx Exp Date: 4/13
-1.04DP� 37�i►.�D
Tukwila Business License No.:
NUS— ()longs" 7
Valuation of project (contractor's bid price): $.1b i V
Describe the scope of work in detail: D nic' m-
Use:
Fuel Type:
LuS-CS eft
Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement [p
Electric ❑ Gas
Other:
H:\Applications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8 -9 -1 I.docx
Revised: August 2011
bh
Page 1 of 2
L.
•
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace. <100k btu
Furnace >100k btu
A
Floor furnace
Suspended/walUfloor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
64
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
A
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
64
Incinerator — domestic
Incinerator —
comm/industrial
•
Unit Type
Qty
Fire damper
Diffuser
A
Thermostat
Wood/gas stove
Emergency generator
Other mec • I -
equipmen uC IX
64
Boiler /Compressor
Qty
0 -3 hp /100,000 btu
3 -15 hp /500,000 btu
15 -30 hp /1,000,000 btu
30 -50 hp /1,750,000 btu
50+ hp /1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING
Signature:
Print Name:
AU HORI D AGENT:
Mailing Address: 4 (00 C7 S I3u2 LQ
H:\Applications\Forms- Applications On Line \2011 Applications'Mechanical Permit Application Revised 8 -9 -1 I.docx
Revised: August 2011
bh
Day Telephone:
City
Date: 1 I'-I r? - i I
State Zip
Page 2 of 2
•
1----
w City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
o
Parcel No.: 0007400033 Permit Number: M11 -167
Address: 8701 EAST MARGINAL WY S TUKW Status: APPROVED
Suite No: Applied Date: 11/18/2011
Applicant: BOEING 14 -01 Issue Date:
Receipt No.: R11 -02575
Payment Amount: $801.65
Initials: JEM Payment Date: 11/29/2011 12:46 PM
User ID: 1165 Balance: $0.00
Payee: HOLADAY PARKS, CONNIE HARDIN
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 06247G
ACCOUNT ITEM LIST:
Description
801.65
Account Code Current Pmts
MECHANICAL - NONRES
000.322.102.00.00 801.65
Total: $801.65
doc: Receipt-06 Printed: 11 -29 -2011
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206 - 431 -3670
Fax: 206 - 431 -3665
Web site: http: / /www.TukwilaWA.gov
RECEIPT
Parcel No.: 0007400033 Permit Number: M11 -167
Address: 8701 EAST MARGINAL WY S TUKW Status: PENDING
Suite No: Applied Date: 11/18/2011
Applicant: BOEING 14 -01 Issue Date:
Receipt No.: R11 -02523
Initials:
User ID:
LAW
1632
Payment Amount: $200.41
Payment Date: 11/18/2011 12:51 PM
Balance: $801.65
Payee: LAW
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 01041G
ACCOUNT ITEM LIST:
Description
200.41
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 200.41
Total: $200.41
doc: Receiot -06 Printed: 11 -18 -2011
04 -02 -2012
City of Tukwila
Department of Community Development
CONNIE HARDIN
4600 S 134 PL
SEATTLE WA 98168
RE: Permit No. M11 -167
BOEING 14 -01
8701 EAST MARGINAL WY S TUKW
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date
of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has
begun for a period of 180 days. Your permit will expire on 05/27/2012.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206 - 431 -2451 to schedule for the next or final inspection.
Each inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to
expire. Address your extension request to the Building Official and state your reason(s) for the need to extend
your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 05/27/2012, your permit will become null
and void and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
fer Marshall
t Technician
File: Permit File No. M11 -167
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431 -3670 • Fax 206-431 -3665
•
PLAN REVIEW /ROUTING SLIP
ACTIVITY NUMBER: M11 -167 DATE: 11 -18 -11
• PROJECT NAME: BOEING #14 -01
SITE ADDRESS: 8701 EAST MARGINAL WY S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTNTS: .1
�I` •
Bthiiding Divisioh"
Public Works n
f\k Mrimil
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-22-11
Complete
Comments:
Incomplete
Not Applicable
Permit Center Use Only'
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route 11 Structural Review Required
REVIEWER'S INITIALS:
No further Review Required
DATE:
n
APPROVALS OR CORRECTIONS:
DUE DATE: 12-20-11
Approved ❑ Approved with Conditions Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only. +
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Documents/routing slip.doc
2 -28 -02
Contractors or Tradespeople Per Friendly Page
1
Page 1 of 2
General /Specialty Contractor
A business registered as a construction contractor with L8i to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name HOLADAY PARKS INC UBI No. 578004089
Phone 2062489700 Status Active
Address 4600 S 134Th Pl License No. HOLADPI379NO
Suite /Apt. License Type Construction Contractor
City Seattle Effective Date 1/21/1983
State WA Expiration Date 9/3/2013
Zip 98168 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty 1
Specialty
2
Effective
Date
Expiration
Date
Status
HOLADI'00105
HOLADAY PARKS
INC
Electrical
Contractor
Hvac /Rfrg Ltd
Energy
Unused
9/25/2000
4/21/2013
Active
HOLADPF376NO
HOLADAY PARKS
FABRCTRS INC
Construction
Contractor
General
Unused
8/20/1963
1/1/1983
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
PARKS, GERALD T JR
Chief Executive Officer
01/21/1983
VAN DER VEEN, JULIE ELIZABETH
Member
08/26/2011
CONNELL, DANIEL AARON
Member
08/26/2011
GIRI, BUIT
Member
08/26/2011
KIEL, RINALD HOWARD
Member
08/26/2011
WHITMYRE, CHRISTIAN
Member
08/26/2011
BECK, DAVID CLARENCE
Vice President
01/21/1983
OCONNOR, BONNY K
Vice President
01/21/1983
NAILON, JUNE ANNETTE
Vice President
01/21/1983
VAN DER VEEN, ERIC M
Vice President
11/04/2010
PIZZEY, GRACE KATHERINE
Vice President
08/26/2011
NELSON, MICHAEL
Secretary
01/01/1980
11/04/2010
PARKS, DAVID L
Treasurer
01/01/1980
11/04/2010
TALBOT, PAUL
Treasurer
01/01/1980
11/04/2010
Bond Information
https://fortress.wa.gov/lni/bbip/Print.aspx
11/29/2011
THEBOE/NG COMPANY
14 -01 PHASE 9 HIGH BAY
RENOVATION
FILE COPY
Penult
p� itippr ��val of arovat
x " bjed
cCc� lD d� � d ea mte�ons.
�lOrize
the violation any code of °ream. Receipt
- ed: 8 01 EAST MARGINAL WAY SOUTH
91
Date it -1riH 1
City Of'�ukwi�
BUILDING DIVISION
LOCATION IN REGION
TO EVERL I I
TUKWILA, WA 98108
SITE PLAN
MUKILTEO
JORGENSEN CORP
lI [
PROJECT
SITE
14 -0 O X 01��7�711J1111J1,7JJlAJlIJJII
IUIUUU --1
KENWORTH CORP
ISSAQUAH
PROJECT
SITE
E
RHONE POULENC
AUBURN
AUBURN
SEPARATE- PEi°FMlT
REQUIRED FOR:
0 Mechanical
ti Electrical
t lambing
Gas Piping
City of Tukwila
BUILDING DIVISION
CODES AND PERMITS
PROJECT TITLE: 14 -01 HIGH BAY RENOVATION
QUANTITY SUBMITTED:
® 5 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT IMPROVEMENT
❑ 4 SETS TENANT IMPROVEMENT (NON— STRUCTURAL)
❑ 3 SETS: FIRE PROTECTION /SPRINKLERS
❑ 2 SETS: TENANT IMPROVEMENT (REVISION)
SUBMITTED FOR PERMIT & REVIEW:
❑ BUILDING
❑ PLUMBING
MECHANICAL
❑ STRUCTURAL
JOB NUMBER: 11347785
GRADING
LANDSCAPE
DEMOLITION
WASHINGTON STATE NON— RESIDENTIAL ENERGY CODE— APPROACHES:
COMPLIANCE OPTION
❑ PERSCRIPTIVE ❑ LPA ❑ ANALYSIS N/A
SPECIAL INSPECTIONS REQUIRED: (PER IBC CH. 17)
❑ WELD ❑
❑ REBAR ❑
❑ STRUCTURAL BOLTING ❑
❑ OTHER
® ELECTRICAL
▪ FIRE PROTECTION
❑ CANTILEVER RACKS
CONCRETE
ANCHOR BOLTS
STRUCTURAL OBSERVATION
CALCULATIONS
TYPE: ATTACHED (YES) (NO)
REVIEWED FOR
CODE COMPL►ANCE
APPROVED
Nf1V 2 8u
i .
Cray of u is
BUILDING VIaION
VICINITY PLAN
PROJECT DESCRIPTION
MODIFY AND ADD DUCTWORK AND DIFFUSERS TO SERVE STORES AREA AT
EXISTING AIR HANDLING UNIT - AHU 34
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
CONTRACTOR LICENSE NUMBER: BOEING * 294ML
BOEING CONTACT: JOHN MURDOCH (253) 740 -0214
EXPIRATION DATE: 1 / 20 / 13
CODE AND BUILDING DATA
EXISTING PERMITTED DATA — NO CHANGE TO OCCUPANCY OR USE:
INTERNATIONAL BUILDING CODE: 2009 EDITION
1. FLOOR AREAS:
a) BUILDING STATUS:
FIRST , FLOOR OFFICE: 31,280 SF
,FIRST FLOOR HIGH BAY: 187,680 SF
FIRST FLOOR MEZZANINES: 500 SF
SECOND FLOOR OFFICE: 31,280 SF
THIRD FLOOR OFFICE: 31,280 SF
FOURTH FLOOR MEZZANINE: 31,280 SF
GROSS AREA: 313,042 SF
b) COVERED LOADING DOCK (14 -16): 5518 SF
2. OCCUPANCY ALLOWED: NO CHANGE
a) ACTUAL OCCUPANT LOAD:
FIRST SHIFT HIGH BAY: 300 OCCUPANTS
FIRST SHIFT OFFICE TOWER: 460 OCCUPANTS
SECOND SHIFT HIGH BAY AND OFFICE: 90 OCCUPANTS
TOTAL ALL SHIFTS: 850 OCCUPANTS
b) OCCUPANCY GROUP: B /F1 OFFICE /MANUF
3. CONSTRUCTION TYPE: TYPE II —B
4. FIRE RESISTIVE REQUIREMENTS: NO CHANGE
a EXTERIOR NON— BEARING WALL:
b STRUCTURAL FRAME:
c PARTITIONS PERMANENT:
d SHAFT ENCLOSURES:
e FLOORS — CEILING /FLOORS:
f) ROOF -- CEILING /ROOF:
g) STAIRWAYS:
5. EXITS: NO CHANGE
a CORRIDORS:
b STAIR ENCLOSURES:
6. BUILDING HEIGHT: NO CHANGE
a HEIGHT (14 -01):
b LOADING DOCK (14 -16):
7. BUILDING HEIGHT IN STORIES: NO CHANGE
a) FLOORS:
8. SEISMIC ZONE:
B. BUILDING ACCESSIBILITY:
NON — COMBUSTIBLE
NON— COMBUSTIBLE
NON — COMBUSTIBLE
1 HOUR
NON— COMBUSTIBLE
NON— COMBUSTIBLE
NON— COMBUSTIBLE
1 HOUR
1 HOUR
eXPIReD
MAY 22 42011
59' -0"
3' -10" (PLUS RAILING)
3 STORIES
1 MEZZANINE STORY
D
AMERICANS WITH DISABILITIES
ACT AND WAC CHAPTER 51
MlLl(o7
RECEIVED
NOV 18 2011
PERMJTCENTER
ISSUED FOR CONSTRUCTION - 0930.11
1 Harris Group Inc.
Engineering for Optimum Performance®
12439.00
® www.harrisgroup.com
REVISION
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATE
14 -01 PHASE 9 AIRPLANE COOLING — IFC 11347785
HGI
SEL
09.30.11
Q� BOEING
N3966 REGISTERED
ARCHITECT
STEPHEN E. LUSK
STATE OF WASHINGTON
ACCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
DEPT. DATE
DRAWN
RVP
CHECKED
PWT
ENGINEER
SEL
CHECKED
ROG
APPROVED
APPROVED
DATE
08.24.11
08.24.11
SUBTITLE
COVER SHEET
CURRENT REVISION
11347785
SYMBOL DATE
1 09.30.11
08.24.11
08.24.11
08.24.11
TITLE
BUILDING 14 -01
ARCHITECTURAL MASTER COL.
TUKWILA, WA
SHEET
GO
JOB NO.
COMP NO.
DWG NO.
1 4-001 —GO
9
WALL LOUVER SEE WALL LOUVER SEE
I— WALL LOUVER, SEE ARCHITECTURAL ARCHITECTURAL
ARCHITECTURAL
SYM
REVISION
BY
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATE
A
B
CAD CONVERSION
RELOCATE A &M TOOL STORAGE
14 -01 PHASE 2 STORES - IFC
WO #32957
11347785
CADDNW
AGS
4.22.98
8.23.00
FSi
11.14.11
PROFESSIONAL STAMP & SIGNATURE
APPLIES TO WORK WITHIN THE CLOUDED
REVISION AREAS ONLY AS INDICATED
�BOE /NG'
LEGEND:
1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS
SEE SHEETS M 1 a, M 1 b AND M 1 c.
GENERAL NOTES:
1. SEE SHEET 1M10 FOR ADDITIONAL NOTES.
VOID
240 #14 GA EXHAUST STACK TO ROOF,
FOR CONTINUATION SEE SHEET RFM16.
CONSTRUCTION NOTES:
RELOCATE TO COLUMN SHOWN ON SHEET M1 M17
TITUS MODEL "TMRA" OR OTHER APPROVED
EXPIRED
MAY x2012
1
T n I I_/-1
1M10A 1M106 1M11A 1M11B �
1M12 1M13 1M14 1M15
1M16 1M17 1M18 1M19
KEY PAN
SCALE: NONE
RECEIVED'
NOV 18 2011 SCALE: 1 /8 " =1' -0"
PERMIT CENTER
0
4'
16'
-
CCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
11.14.11
DEPT.
DATE
DRAWN
R. ADEE
DATE
CHECKED
M. FEINSTEIN
ENGINEER
M. FEINSTEIN
SUBTITLE
DUCTWORK PLAN
CURRENT REVISION SYMBOL
11347785 B
DATE
11.14.11
CHECKED
K. WIKSTROM
APPROVED
K. RAMSEY
APPROVED
7.25.94
TITLE
MECHANICAL MASTER
BUILDING 14 -01
COL. D— E/6 -9.2
THOMPSON, WA
SHEET
M1M16
JOB NO.
COMP NO.
DWG NO.
14- 001 —M1 M
16
0
`� -
---
1
I
1
I
I
SUPPLY A
AIR D
DIFFUSER
CFM
%MN
PAINT SPRAY \
I I
I I
I I
I I
1 0
0 (e)TEMPERATURE
,
',.,,SENSOR TO AHU -34
.y
EDGE OF CANOPY %
6
16 "0
I
1 1
REF
6 1
0 6
1 1
1 1
w A
-__ ',,
I I
_,,,
A35U `.'.., \
\' I
P
16 "0
EF
8 \
DD 3
DD D
3 K
��
- \
\ /
\ / \ / \ / \/
\ /j /
/ \ / \/ �
�' -, -
\ / \
SYM
REVISION
BY
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATE
A
B
CAD CONVERSION
RELOCATE A &M TOOL STORAGE
14 -01 PHASE 2 STORES - IFC
WO #32957
11347785
CADDNW
AGS
4.22.98
8.23.00
FSi
11.14.11
PROFESSIONAL STAMP & SIGNATURE
APPLIES TO WORK WITHIN THE CLOUDED
REVISION AREAS ONLY AS INDICATED
�BOE /NG'
LEGEND:
1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS
SEE SHEETS M 1 a, M 1 b AND M 1 c.
GENERAL NOTES:
1. SEE SHEET 1M10 FOR ADDITIONAL NOTES.
VOID
240 #14 GA EXHAUST STACK TO ROOF,
FOR CONTINUATION SEE SHEET RFM16.
CONSTRUCTION NOTES:
RELOCATE TO COLUMN SHOWN ON SHEET M1 M17
TITUS MODEL "TMRA" OR OTHER APPROVED
EXPIRED
MAY x2012
1
T n I I_/-1
1M10A 1M106 1M11A 1M11B �
1M12 1M13 1M14 1M15
1M16 1M17 1M18 1M19
KEY PAN
SCALE: NONE
RECEIVED'
NOV 18 2011 SCALE: 1 /8 " =1' -0"
PERMIT CENTER
0
4'
16'
-
CCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
11.14.11
DEPT.
DATE
DRAWN
R. ADEE
DATE
CHECKED
M. FEINSTEIN
ENGINEER
M. FEINSTEIN
SUBTITLE
DUCTWORK PLAN
CURRENT REVISION SYMBOL
11347785 B
DATE
11.14.11
CHECKED
K. WIKSTROM
APPROVED
K. RAMSEY
APPROVED
7.25.94
TITLE
MECHANICAL MASTER
BUILDING 14 -01
COL. D— E/6 -9.2
THOMPSON, WA
SHEET
M1M16
JOB NO.
COMP NO.
DWG NO.
14- 001 —M1 M
16
KEY PAN
SCALE: NONE
RECEIVED'
NOV 18 2011 SCALE: 1 /8 " =1' -0"
PERMIT CENTER
0
4'
16'
-
CCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
11.14.11
DEPT.
DATE
DRAWN
R. ADEE
DATE
CHECKED
M. FEINSTEIN
ENGINEER
M. FEINSTEIN
SUBTITLE
DUCTWORK PLAN
CURRENT REVISION SYMBOL
11347785 B
DATE
11.14.11
CHECKED
K. WIKSTROM
APPROVED
K. RAMSEY
APPROVED
7.25.94
TITLE
MECHANICAL MASTER
BUILDING 14 -01
COL. D— E/6 -9.2
THOMPSON, WA
SHEET
M1M16
JOB NO.
COMP NO.
DWG NO.
14- 001 —M1 M
16
9.2
9.L
f0.2 104
12\1 122 124
114- 001 - 4001 -3M O 114-001-4023—M1
ED E OF CANOPY
114- 001 -40
(TYP)
1 -3M4A 114-001-4023—M1
SUPPLY AIR DIFFUSER
16 "0 NECK 1200 CFM
(TYPICAL)
0
0
/ COIL PULL
AREA
ELECTRICAL
(REF)
ELECTRICAL
CLEARANCE
WALL LOUVER
SEE ARCHITECTURAL
DIFFUSERS DN
FROM ROOF
DUCTING (TYP)
/REF
�8
TRANSFORMER
(REF)
PARTIAL FIRST FLOOR NEZZA \I \E PLA\
SCALE: 1/8"=1' —0"
SYM
REVISION
BY
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATE
CAD CONVERSION
A
14 -01 PHASE 2 STORES - IFC
11347785
CADDNW
FSi
04.24.98
11.14.11
PROFESSIONAL STAMP & SIGNATURE
APPLIES TO WORK WITHIN THE CLOUDED
REVISION AREAS ONLY AS INDICATED
�BOE /NG'
R E i FORV.
CODE DOMPUANDE
APPROVED
Nov 282011
��� Tukwila
� NG
(VISION
LEGEND:
1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS
SEE SHEETS M 1 a, M 1 b AND M 1 c.
GENERAL NOTES:
1. SEE SHEET 1M10 FOR NOTES.
44'1
CONSTRUCTION NOTES:
RELOCATED T'STAT —MOUNT ON COLUMN AT 5' -0" AFF
TITUS MODEL "TMRA" OR OTHER APPROVED
RECEIVED
NOV 18 2011
PERMIT CENTER
EXPIRED
MAY 22 2-012
1
T
n
T
T_/-1
M1 M12
M1M17
-.,
KEY PLAN
SCALE: NONE
4'
4' 8'
16'
INN NM
1•11 -- NO-
SCALE: 1/8"=1'-0"
CCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
APPROVED BY
DEPT. DATE
DRAWN
D.MCCLUNG
DATE
CHECKED
M.FEINSTEIN
ENGINEER
M.FEINSTEIN
SUBTITLE
DUCTWORK PLAN
CURRENT REVISION SYMBOL DATE
11347785 A 11.14.11
CHECKED
K.WIKSTROM
APPROVED
K.RAMSEY
APPROVED
TITLE
BUILDING 14 -01
MECHANICAL MASTER COL D —E/9.2 -12.4 THOMPSON, WA
SHEET
M1M17
JOB NO. COMP NO.
DWG NO.
14- 001 —M1M17
114/66
37/113 -'
3 "HWR
3 "HWS
MEZZANINE
•
104
3 "HWS
3 "HWR
4 "CHWS
4 "CHWR
10.2
_---''
ok,
4 "CHWR
4 »CHWS
<AJ>
34
G+—.14-1
I .. -F0
-4-41.-+D
C
37/113 WITH
2" ACOUSTIC
DUCT LINER
1
60/42
46/50
52/100 WITH 2"
ACOUSTIC DUCT LINER
12/12
(E )
SECTIO\
SCALE: 1/4 " =1' -0"
1M17, M 1 M 17, M 1 M67 M508
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 8 2011
City of Tukwila
BUILDING DIVISION
PROFESSIONAL STAMP & SIGNATURE
APPLIES TO WORK WITHIN THE CLOUDED
REVISION AREAS ONLY AS INDICATED
SEE
DRAWING ARCHITECTURAL
FOR LOUVER
EXPI ` ED
MAY 2Zz01Z
66/114
4 "CHWR
4 "CHWS
3 "HWR
3 "HWS
MEZZANINE
37/113-
II�
3 "HWS
4 "CHWS
60/42
A H U)
34
�I `,x
/ 1 �•< y 11
�
11 1 � >C�; , � 1 1
50/46 --T
LEGEND:
1. FOR MECHANICAL LEGENDS AND ABBREVIATIONS
SEE SHEETS M1a, M1b, AND M1c.
GENERAL NOTES:
1. SEE SHEET 1M10 FOR NOTES.
CONSTRUCTION NOTES:
16/16
12/12
12 12
VD
100/52 WITH
2" ACOUSTIC
DUCT LINER
(041
EXPIRED
MAY 222012
FIN FLOOR EL 116' -0"
SECTIO\
SCALE: 1/4 " =1' -0"
1M17, M1M17, M1M67 M508
NOTE:
WALL NOT SHOWN FOR CLAIRITY
(REF)
RECEIVED
NOV 18 2011
PERMITCENTER
SYM
REVISION
RECORD DRAWING
A
14 -01 PHASE 2 STORES - IFC 11347785
BY
KB /KW
FSi
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATE
KR
3.31.95
11.14.11
tifirOE /N6'
11.14.11
sin
CCEPTABILITY
THIS DESIGN AND /OR
SPECIFICATION IS APPROVED
DRAWN
D.MCCLUNG
DATE
CHECKED
M.FEINSTEIN
SUBTITLE
HVAC SECTIONS AND DETAILS
CURRENT REVISION
11347785
SYMBOL
A
DATE
11.14.11
APPROVED BY
DEPT.
DATE
ENGINEER
M.FEINSTEIN
CHECKED
K.WIKSTROM
APPROVED
K.RAMSEY
APPROVED
TITLE
MECHANICAL MASTER
BUILDING 14 -01
COL
THOMPSON, WA
SHEET
M5O8
JOB NO.
COMP NO.
DWG NO.
14- 001 -M5
08