Loading...
HomeMy WebLinkAboutPermit PG10-004 - WEBER RESIDENCEWEBER RESIDENCE 4624 S 146 ST PG1 0-004 Parcel No.: 0040000581 Address: Suite No: City* Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us 4624 S 146 ST TUKW PLUMBING /GAS PIPING PERMIT Permit Number: Issue Date: Permit Expires On: PG 10 -004 01/21/2010 07/20/2010 Tenant: Name: WEBER RESIDENCE Address: 4624 S 146 ST , TUKWILA WA Owner: Name: SCHMETZER BRIAN +BESAGNO JAC Address: 5223 18TH AVE SW , SEATTLE WA Contact Person: Name: JOSH BAILEY Address: 26458 MAPLE VALLEY HY SE , MAPLE VALLEY WA Contractor: Name: SUMMIT HEAT N AIR Address: 26458 MAPLE VALLEY HY SE , MAPLE VALLEY WA Contractor License No: SUMMIHN953P4 Phone: Phone: 206 936 -1266 Phone: 425 432 -4192 Expiration Date: 12/11/2011 DESCRIPTION OF WORK: GAS PIPING TO FURNACE FROM METER Value of Plumbing /Gas Piping: Fees Collected: $1,000.00 $96.60 Uniform Plumbing Code Edition: 2006 International Fuel Gas Code Edition: 2006 FIXTURE TYPE AND QUANTITY Plumbing Bathtub or combination bath/shower 0 Bidet 0 Clothes washer, domestic 0 Dental unit, cuspidor 0 Dishwasher, domestic, with independent drain 0 Drinking fountain or water cooler (per head) 0 Food -waste grinder, commercial 0 Floor drain 0 Shower, single head trap 0 Lavatory 0 Wash fountain Receptor, indirect waste 0 Sinks 0 Urinals 0 Water Closet 0 0 Plumbing (cont.) Building sewer and each trailer park sewer 0 Rain water system - per drain (inside bldg) 0 Water heater and /or vent 0 Industrial waste treatment interceptor, including its trap and vent, except for kitchen type grease interceptors 0 Repair or alteration of water piping and/or water treatment equipment 0 Repair or alteration of drainage or vent piping 0 Medical gas piping system serving (1 -5) inlets /outlets for a specific gas 0 Medical gas piping (6 +) inlets /outlets 0 Gas Piping Gas piping outlets (0 -5) 1 Gas piping outlets (6 +) 0 * *continued on next page ** doc: UPC -7/07 PG 10 -004 Printed: 01 -21 -2010 City o!Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206- 431 -2451 Web site: http: / /www.ci.tukwila.wa.us Permit Number: PG10 -004 Issue Date: 01/21/2010 Permit Expires On: 07/20/2010 Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied amin ith, Date: 041 l 1 l P d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not presu to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the % •S •rma - of work am authorized to sign and obtain this plumbing /gas piping permit. Signature: dh .V�—� Date: Print Name: gi./ /-2/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -7/07 PG 10 -004 Printed: 01 -21 -2010 Parcel No.: Address: Suite No: Tenant: S City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us 0040000581 4624 S 146 ST TUKW WEBER RESIDENCE PERMIT CONDITIONS Permit Number: Status: Applied Date: Issue Date: PG 10 -004 ISSUED 01/21/2010 01/21/2010 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. * *continued on next page ** doc: Cond -10/06 PG 10 -004 Printed: 01 -21 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http://www.ci.tukwila.wa.us I hereby certify that I have read these conditions and will comply with them as outlined. All provisions of law and this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provision of any other work construction or the performance of work. Signature: Print Name: Ja 1 Date: / 7-- ordinances governing or local laws regulating doc: Cond -10/06 PG 10 -004 Printed: 01 -21 -2010 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila.wa.us Plutnbing %Ga's Perm itNo:..IJ Project No For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** Site Address: 1 c q ,/ /t / /I/ Tenant Name: 0 /Gtji'I L v t e/ Property Owners Name: Mailing Address: King Co Assessor's Tax No.: 001100 '061 Suite Number: New Tenant: // Floor: ❑ Yes ..No City State Zip CONTACT PERSON -Who do we contact.when • your permit • isrea`dy to be issued Name: Mailing Address: /1 2 Day Telephone: h one: Z[/t 72 �4 1/1Y 1 to p E -Mail Address: Fax Number: PLUMBING: / GAS 'PIPING'CONTRACTOR INFORMATI Company Name: Mailing Address: Contact Person: E -Mail Address: Cit,,ninfoL h2�G /j(I - /l/'/�7y'G��-/`�y '/���) _264 J" / / G I/ i4 ' s&' / //°/2/l City t /7 h,� state U 23 f 1.4 t///7 Day Telephone: 206 `55 — � 66 1 j-� Fax Number: Contractor Registration Number: S ( ) fl1 IY J- kW J 3%'4 Expiration Date: , 'ARCHITECT' OF _ All`plans`must be wet stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD = All plans must be wet stamped by, Engineer` of Record. Company Name: Mailing Address: Contact Person: E -Mail Address: H:Wpplications \Forms - Applications On Line\2009 Applications \1 -2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1 -2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 2 Valuation of Project (contractor's bid price): $ 26 50 c5e7 944 p /p />1 N4.,--/ e__ from 7)7P - Scope of Work (please provide detailed information): Building Use (per Intl Building Code): J�JJ%)l'fl, C)/ 4 7 Occupancy (per Int'l Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and /or gas piping outlets being installed and the quantity below: Fixture Type: Y ' _ p Qty ; . Fixture Type:- - Qty,: Fixture Type: ,: =. ' � Qty. Fixture•Type: Qty Bathtub or combination bath/shower Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and /or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and /or water treatment equipment Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets I Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN Signature: Print Name: Date: / " iv Day Telephone: 7-0.--3q6- 11�� Cab %- Mailing Address: 2 State Zip Date Application Accepted: O b Date Application Expires: Staff Initials: I / H:\Applications\Fonns- Applications On tine \2009 Applications \1 -2009 - Plumbing -Gas Piping Permit Application.doc Revised: 1 -2009 bh Page 2 of 2 of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: //www.ci.tukwila.wa.us SET RECEIPT Copy Reprinted on 01 -21 -2010 at 09:40:36 01/21/2010 RECEIPT NO: R10 -00084 Initials: JEM Payment Date: 01/21/2010 User ID: 1165 Total Payment: 260.70 Payee: BAILEY INDUSTRIES, SUMMIT HEAT -N -AIR SET ID: S000001333 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member M10 -005 PG10 -004 TOTAL: Amount 164.10 96.60 96.60 TRANSACTION LIST: Type Method Description Amount Payment Check 7830 260.70 TOTAL: 260.70 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - RES 000.322.103.00.0 MECHANICAL - RES 000.322.102.00.0 96.60 164.10 TOTAL: 260.70 PAYMENT RECEIVED INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION g 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3 Pro ect: fif_�°r /PrS Type of Inspection: /-, v 4I - CsiS Address: 4/62rs /VC _. Date Called: Special Instructions: \ Date Wanted: oZ -- / 7 - /!, a.m,. p.m. Requester: Phone No: B4.a- '7sV -sr 7 5 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4/%/.44T / (( , /6f // /1v+4 / Inspe or: Date: —/ 7--,b .00 REINSPECTION \tEE RR) RED. Prior to inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: _.._.�-- "�"`�w,'i �"z a '�.J..!2T .''.•1e". _�.�.:j =.t.�; ,r`.s'o°Y :'T4 :e�,t'.%;t =a L7.`!$.'.�s%s. <<,'La..;.t- ;_rT"'Yi:d INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION ? X300 Southcenter Blvd., #100, Tukwila, WA 98188 (206)431 -3670 Prolec : eY Res Type ofiispection: i'-+- ( Ad ress: Date Called: nf �ak_ r ' ,/, Special Instructions: Date Wanted: I _ 22-16 (a.m: p.m. Requester: Phone No: G- n Approved per applicable codes. 1 ElCorrections required prior to approval. c -, COMMENTS: ( r- Aq D I o J -Q -v_. (1 ... y k ` 4 5' 0 s r ' ,/, 2S- — G- n s ,in A3? 4 5;7 . iv Insp(eotor: ❑ $ 60.00 REINSPECTIO EE Date: 1 REQUIRED. Prior to inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Receipt No.: Date: Untitled Page • • General /Specialty Contractor A business registered as a construction contractor with Lai to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company SUMMIT HEAT N AIR UBI No. 4254324192 Status 26458 MAPLE VALLEY HWY SE MAPLE VALLEY WA 98038 KING Corporation License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602223106 ACTIVE SUMMIHN953P4 CONSTRUCTION CONTRACTOR 11/14/2005 12/11/2011 HTG /VENT /AIR CONDITIONING UNUSED Other Associated Licenses License Name Type Specialty Specialty 2 Effective Expiration Dat Status TERRYMF942DL TERRY MORRIS FUEL CONSTRUCTION CONTRACTOR OTHER (SPECIFY) AIR CONDITIONING 3/13/2006 3/13/2008 OUT OF BUSINESS Business Owner Information Name Role Effective Date Expiration Date BAILEY, JOSH PRESIDENT 10/21/2005 Bond Amount BAILEY, SHAUNA J SECRETARY 10/21/2005 7900324776 BAILEY, SHAUNA J TREASURER 10/21/2005 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 NATIONWIDE MUTUAL INS 7900324776 11/13/2007 Until Cancelled $6,000.00 11/26/2007 2 NATIONWIDE MUTUAL INS CO 7900640331 10/03/2006 Until Cancelled 11/13/2007 $12,000.0010/25 /2006 1 NATIONWIDE MUTUAL INS BD7900595078 11/14/2005 Until 01/21/2006 $6,000.00 11/14/2005 https://fortress.wa.gov/lni/bbip/Detail.aspx 01/21/2010