Loading...
HomeMy WebLinkAboutPermit PG11-062 - HEATHERWOOD APARTMENTS - BUILDINGHEATHERWOOD APARTMENTS 5851 S 152 ST PG1 1 -062 Parcel No.: Address: City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206 -431 -2451 Web site: http: / /www.TukwilaWA.gov 5851 S 1S2 ST TUKW PLUMBING /GAS PIPING PERMIT Project Name: HEATHERWOOD APARTMENTS - BLDG A Permit Number: PG11 -062 Issue Date: 04/14/2011 Permit Expires On: 11/28/2011 Owner: Name: Address: Contact Person: Name: ANGELINA RUIZ Address: 11831 SE 32 ST , BELLEVUE WA 98005 Email: ANGELINA.RUIZ0625 @GMAIL.COM Contractor: Name: PIPELINE PLUMBING & CONSULTING, INC. Address: 11831 SE 32 ST , BELLEVUE WA 98005 Contractor License No: PIPELPC 101 BW Phone: 425 644 -2622 Phone: 425 644 -2622 Expiration Date: 09/13/2012 DESCRIPTION OF WORK: INSTALL NEW HOT AND COLD COPPER WATER PIPING SYSTEM FOR TOTAL OF 12 UNITS. REVISION #1: COPPER PIPING WILL NOT BE USED. USING PEX. REVISION #2: REDUCE SCOPE OF WORK TO (6) UNITS IN THIS BUILDING. UNITS 201, 202, 203, 301, 302 & 303. WER REVISION #3: REVISION IS TO CORRECT UNITS IN STACK ORDER. UNITS SHOULD BE 102, 202, 302 AND 103, 203, 303. WER Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: $12,000.00 $60.90 Permit Center Authorized Signature: t,JA Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: (17'- / 4 t/ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: ovr-Ckc s„ Date: 6- 2-11 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG11 -062 Printed: 06 -07 -2011 • • PERMIT CONDITIONS Permit No. PG11 -062 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG 11 -062 Printed: 06 -07 -2011 Parcel No.: Address: City o!I'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov 5851 S 152 ST TUKW PLUMBING /GAS PIPING PERMIT Project Name: HEATHERWOOD APARTMENTS Permit Number: PG11 -062 Issue Date: 04/14/2011 Permit Expires On: 11/20/2011 Owner: Name: Address: Contact Person: Name: ANGELINA RUIZ Address: 11831 SE 32 ST , BELLEVUE WA 98005 Email: ANGELINA.RUIZ0625 @GMAIL.COM Contractor: Name: PIPELINE PLUMBING & CONSULTING, INC. Address: 11831 SE 32 ST , BELLEVUE WA 98005 Contractor License No: PIPELPC 101BW Phone: 425 644 -2622 Phone: 425 644 -2622 Expiration Date: 09/13/2012 DESCRIPTION OF WORK: INSTALL NEW HOT AND COLD COPPER WATER PIPING SYSTEM FOR TOTAL OF 12 UNITS. REVISION #1: COPPER PIPING WILL NOT BE USED. USING PEX. REVISION #2: REDUCE SCOPE OF WORK TO (6) UNITS IN THIS BUILDING. UNITS 201, 202, 203, 301, 302 & 303. WER Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: $12,000.00 $60.90 Permit Center Authorized Signature: Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 L0 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions on the back of this o - rmit. Signature: Print Name: o ; s Date: 6— o?"l —! / This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG 11 -062 Printed: 05 -25 -2011 • • PERMIT CONDITIONS Permit No. PG11 -062 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG 11 -062 Printed: 05 -25 -2011 Parcel No.: Address: City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov 5851 S 152 ST TUKW PLUMBING /GAS PIPING PERMIT Project Name: HEATHERWOOD APARTMENTS Permit Number: Issue Date: Permit Expires On: PG11 -062 04/14/2011 10/11/2011 Owner: Name: Address: Contact Person: Name: Address: Email: ANGELINA RUIZ 11831 SE 32 ST , BELLEVUE WA 98005 ANGELINA.RUIZ0625@GMAIL.COM Contractor: Name: PIPELINE PLUMBING & CONSULTING, INC. Address: 11831 SE 32 ST , BELLEVUE WA 98005 Contractor License No: PIPELPC 101 BW Phone: 425 644 -2622 Phone: 425 644 -2622 Expiration Date: 09/13/2012 DESCRIPTION OF WORK: INSTALL NEW HOT AND COLD COPPER WATER PIPING SYSTEM FOR TOTAL OF 12 UNITS. REVISION #1: COPPER PIPING WILL NOT BE USED. USING PEX. Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: Permit Center Authorized Signature I hereby certify that I have read an governing this work will be compli $12,000.00 $60.90 Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not p construction or the performance of work. on the back of this permit. Signature: Print Name: e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this plumbing /gas piping permit and agree to the conditions IJ/ 71200zhc Ce9e,ir Date: Wi /// This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG11 -062 Printed: 05 -17 -2011 PERMIT CONDITIONS Permit No. PG11 -062 1: ** *PLUMBING AND GAS PIPING * ** • 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire - resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG 11 -062 Printed: 05 -17 -2011 Parcel No.: Address: City akukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: //www.ci.tukwila.wa.us 5851 S 152 ST TUKW PLUMBING /GAS PIPING PERMIT Project Name: HEATHERWOOD APARTMENTS Permit Number: Issue Date: Permit Expires On: PG11 -062 04/14/2011 10/11/2011 Owner: Name: Address: Contact Person: Name: Address: Email: ANGELINA RUIZ 11831 SE 32 ST , BELLEVUE WA 98005 ANGELINA.RUIZ0625 @GMAIL. COM Contractor: Name: PIPELINE PLUMBING & CONSULTING, INC. Address: 11831 SE 32 ST , BELLEVUE WA 98005 Contractor License No: PIPELPC101BW Phone: 425 644 -2622 Phone: 425 644 -2622 Expiration Date: 09/13/2012 DESCRIPTION OF WORK: INSTALL NEW HOT AND COLD COPPER WATER PIPING SYSTEM FOR TOTAL OF 12 UNITS. Value of Plumbing /Gas Piping: Fees Collected: Electrical Service Provided by: $12,000.00 $60.90 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: (7401[( xami, ed this permit and know the same to be true and correct. All provisions of law and ordinances with, hether specified herein or not. The granting of this permit does not pr constructio or the performance of work. on the bac • • this pe 1 't. e to . ive authority to violate or cancel the provisions of any other state or local laws regulating autho 'zed to sign and obtain this plumbing /gas piping permit and agree to the conditions Signature: Print Name: &o\lVA\f4 1�u12 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: UPC -4/10 PG 11 -062 Printed: 04 -14 -2011 b • PERMIT CONDITIONS Permit No. PG11 -062 1: ** *PLUMBING AND GAS PIPING * ** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R -3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor /ceiling assemblies and fire- resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG11 -062 Printed: 04 -14 -2011 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us �( �n Plumbing /Gas Permit • No ;•' - 1--__ OL!' 1 1 Project No. (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *Please Print ** SITE LOCATION Site Address: 5851 S 152nd ST, Tukwila, WA 98188 Tenant Name: Laders Heatherwood Apts King Co Assessor's Tax No.: Suite Number: New Tenant: Property Owners Name: Glen Una Properties Floor: ❑ Yes ❑..No Mailing Address: Zip City State CONTACT PERSON — Who do we contact when your permit is ready to be issued • Name: Angelina Ruiz Mailing Address: 11831 Se 32nd St E -Mail Address: angelina.ruiz0625 @ gmail.com Day Telephone: Bellevue (425) 644 -2622 WA City State Fax Number: (425) 644 -2788 98005 Zip PLUMBING / GAS PIPING CONTRACTOR INFORMATION Company Name: Pipeline Plumbing & Consulting, INC. Mailing Address: 11831 SE 32nd ST Contact Person: Angelina Ruiz E -Mail Address: angelina.ruiz0625 @gmail.com Contractor Registration Number: PIPELPC101 BW Bellevue City Day Telephone: Fax Number: WA State (425) 644 -2622 (425) 644 -2788 98005 Zip Expiration Date: 09/13/2012 ARCHITECT OF RECORD — All plans must be stamped by Architect of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD — All plans must be stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip H_ Applications \Forms - Applications On Line\2010 Applications \7 -2010 - Plumbing-Gas Piping Permit Application doc Revised: 7 -2010 bh Page 1 of 2 Valuation of Project (contractor's bid price): $ 12,000.00 Scope of Work (please provide detailed information): of 12 units. Installing new hot & cold copper water piping system for a total Building Use (per Int'l Building Code): Occupancy (per Int'I Building Code): Utility Purveyor: Water: Sewer: Indicate type of plumbing fixtures and/or gas piping outlets being installed and the quantity below: Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Fixture Type: Qty Bathtub or combination bath/shower , MI- Bidet Clothes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks iie‘ Urinals Water Closet /, Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or vent Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen ( >750 gallon capacity) Repair or alteration of water piping and/or water treatment equipment 1 Repair or alteration of drainage or vent piping Medical gas piping system serving 1 -5 inlets /outlets for a specific gas Each additional medical gas inlets /outlets greater than 5 Backflow protective device other than atmospheric -type vacuum breakers 2 inch (51 mm) diameter or smaller Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1 -5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF ; E STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING NE R r AUTHORIZED A : Signature: Date: /Ir./HO\ Print Name: Angelina Ruiz Day Telephone: 425 - 644 -2622 Mailing Address: 11831 SE 32nd St Bellevue Wa 98005 IDate Application Accepted: f (1 I l City State Date Application Expires: Staff Initials: H:\Applications\Fonns- Applications On Line\2010 Applications \7 -2010 - Plumbing -Gas Piping Permit Application.doc Revised: 7-2010 bh Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us RECEIPT Parcel No.: Permit Number: PG11 -062 Address: 5851 S 152 ST TUKW Status: PENDING Suite No: Applied Date: 04/14/2011 Applicant: HEATHERWOOD APARTMENTS Issue Date: Receipt No.: R11 -00720 Payment Amount: $60.90 Initials: JEM Payment Date: 04/14/2011 11 :55 AM User ID: 1165 Balance: $0.00 Payee: PIPELINE PLUMBING TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 314155 ACCOUNT ITEM LIST: Description 60.90 Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 60.90 Total: $60.90 doc: Receiot -06 Printed: 04 -14 -2011 - INSPECTIO NO. INSPECTION RECORD 6c) 06) Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Ike Vj 0 0 A Typ nistrai: lilk jooks 4 A ddress:_ 5/(-5 i -s‘• /52 - Date Call- -1-- lez Ult'■ ---r-AS. — ... Special Instructions: ./. Date Wanted: a.m. Requester: Phone No: z-53 -Ego - 6 13ip. Approved per applicable codes. LJCorrections required prior to approval. COMMENTS: Orout 1 ou ( e)r- f3K 6 v\, • u i■--1--- o wx.,{ ) / 1 0 eL ?,(92_, 302- AA.6 (02 .2,03, ? I . -,...__ , REINSPECTION FEE R QUIRED. Prior to next inspeCtion., fee must be.a% paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectionr. • • INSPECTION RECORD Retain a copy with permit INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING 9IVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 - P6i( Projec : e7 LJ 0 d eP Type of Inspection: F : "/A-L PU 04'11 . Address: ,_49 Date Called: Special Instructions: _..1 Date Wanted: a.m. (r) - -7- (/ em7 Requester: Phone No COMMENTS: ElCorrections required prior to approval. UA'T os_ p(oe Inspecto Date: (...„ (1 • ■ - `°.�' ; INSPECTION RECORD P6(14. 4{49 Retain a copy with permit • • INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 I.• • (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Proj C3 ci TYpeIrspectio�� --- (3( �J JAL Ai ` C/`�u Address: ._57 - 5 / `• Date Called: r -5-2 Special Instructions: Date Wanted 1 -' a.m 11 p.m. Requester: Phone o- _ 8 V 6 ( .3-6 ❑ Approved per applicable codes. � Corrections required prior to approval. J COMMENTS: .•; • Inspec or: / ..-- �J •'� REINSPECTION FEE REQUIRED. Prior to next inspection. fee !bust be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: ` INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION (206) 431 -3670 PERMIT NO. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431 -2451 Pro�e4r Aw O Tyke of Ins e6on`; .�– Pitt Address: Date Called: Special Instructions: • Date Wanted: . r r �` CD t ��'' p.m. Requester: Phone No' 25"3 -- es. 4 ..... s it 3 ElApproved per applicable codes. COMM paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspectiori: • = : INSPECT ON NO. INSPECTION RECORD. Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 70 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Inspection Request Line (206) 431 -2451 Ae- Project: , elt J66 Type i- IOsAtior ti , .6 A 6 Address: 6i( 51 5- . Date Called: �-�-� ^� / /3/.. Special Instructions: • Date Wanted: y`3 I -// / �m� p• Requester: Phone 2 5:3 - X84 - 613i ElApproved per applicable codes. COMMENTS: ~r� ElCorrections required prior to approval. . jai 1-a'(' 317 /03 -7,3 6. 3 63 pA?flJA,v r a J A (.1 • Inspector: Date " (/ 1 r7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. P.colt-a4Z.. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 *',r ; (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Proj t: t.,) /y._ o 494 Type Inet- IC -. C(4 �.` A/J ' Ad ress 5 S, /`d Z -s' / S�-- Date Called: l / - Special Instructions: Date Wanted:1 —3( —if �- Requester: Phone Ito: S/SjQ ! /40310 ElApproved per applicable codes. aCorrections required prior to approval. COMMENTS: flki---nq kr v --)( Are') M % ute- 0003, oAp -r-t, «t-7ea- !+,( 2.dI 2Df 7,'-!°17.-41 ?,443o 7 b \0L t - 6! „..,____N 1.\ 1 Inspecttpr: Date: �? t n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. -0 I INSPECTION NO. INSPECTION RECORD Retain a copy with permit 12'6 11-e&L PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (2— (206) 431-3670 Permit Inspection Request Line (206) 431-2451 proJetfeaat,.. ,, , LtJU U A ArtAYPe of Inpection: 1 k r-vv fL, Addresv) 51 5 1 s...„ 1 c2;....3.1__Date Called: Special Instructions; pAr-1-,,A4 )\piorAupif O W(L4 Date Wanted: ,..-. -.... -, Requester: Phone No: 2- 5' ? — skY4- Co(36 ElApproved per appIicabe codes. ElCorrections required prior to approval. COMMENTS: 3 e 4 dk. -7--ii LIW -4: 103 7433 .4' o .1?----h-f-----&i 19 n /tem )----e) AA.6( •r,r 0-'! (r-'u a a i 4Z;Ich) r-,`",e' gr. .-fir:',....7 1 3,i drl— 4? A:' e,..21-11y loin re / Ili I A ill A Insp ctor: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • ;!!. PROJECT NAME: r d' wpp SITE ADDRESS: ,j-k.S, t s ORIGINAL ISSUE DATE: LA- (Li- PERMIT NO: • ?CH— 0(0-2- REVISION LOG REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE ISSUED DATE STAFF INITIA S L S-1 L j Utt_ I'1��I o 1 T- t) r ■ p•,,,._ CO r "A-C) ?EX Summary of Revision: � - t" Received by: 777ot frot S sew!. (TA REVISION NO. DATE RECEIVED STAFF INITI LS STAFF INITIALS ISSUED DATE STAFF INITIALS a- s -)-s -11 Utt_ Summary of Revision: COpeult V■ r 10 Summary of Revision: Q,eJte . s c.��x 1-r, {2 ..4, f Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITI LS ISSUED DATE STAFF INITIALS 3 (o -)- I Summary of Revision: COpeult V■ r 10 Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: //www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: lD ` �' k Plan Check/Permit Number: G t 1 0 IQ ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # '— Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: ii`e-gt/41 C-11'07/ a f Project Address: _ S 8 51 5 - / S� S 1- ' Th t,-,77,t. Contact Person: liVic, Se 70- frA Phone Number: ..S.3- gaD -6 '/?(' Summary of Revision: C46,14 9? Sccie Oc4 e ik fro t�1 10a/do02,30a1 IO33ac O3 JUN 0 7 2011 PERMIT cif+ Sheet Number(s): "Cloud" or highlight all areas of revision including date of revisi Received at the City of Tukwila Permit Center by: l}— Entered in Permits Plus on G9 - ( H: Application Torms- Applications On Line\2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Web site: http: //www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: 1)611-61,9), ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # Revision # 2- after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: �oyq �' 1ivo-J olpar ?, i Project Address: 1 / (2 3 / S-:° S 11- 1/ e Uin-e_ tA,e-v Contact Person: VVL ova t15 �,p�ovr Phone Number: 2 G - g cao - (l J?,6' Summary of Revision: £ .e d t co S O T e"-f . p f' k 6' kfro'fr iTh 5e1J cy, )02 U n, -% 11 Boa1,203 --30)1 go .2, 303. CITY OF 11.00411.iti MAY 2 5 2011 Sheet Number(s): "Cloud" or highlight all areas of revision including date of re • n Received at the City of Tukwila Permit Center by: r 4' Entered in Permits Plus on H:\Applications\Forms- Applications On Line \2010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7 -2010 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: ❑ Response to Incomplete Letter # ❑ Response to Correction Letter # l — Revision # 1 after Permit is Issued TGt1- OtoZ ❑ Revision requested by a City Building Inspector or Plans Examiner e4e - t.v, o e�i / ' 'm-er)45 SSSI S l.Sc s+ 4/9ei r,,Z C6 4vvre red (oppes^ 4-6 Project Name: Project Address: Contact Person: Summary of Revision: Phone Number: fwv'teltvziA MAY 17 2011 PEAMiT CEN1'EA L s- 6' tfa--a6aa tp Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on ---1-cm7E11,1[Es H:\Applicatrons \Forms - Applications On Lrn0010 Applications \7 -2010 - Revision Submittal.doc Created: 8 -13 -2004 Revised: 7.2010 Contractors or Tradespeople P ller Friendly Page II General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PIPELINE PLUMBNG /CONSULTNG INC UBI No. 601189310 Phone 4256442622 Status Active Address 11831 Se 32Nd St. License No. PIPELPC101BW Suite /Apt. License Type Construction Contractor City Bellevue Effective Date 1/16/1990 State WA Expiration Date 9/13/2012 Zip 98005 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty Specialty 2 Effective ExpDiaYeion Status PIPELP'159NT PIPELINE PLUMBING Construction Contractor plumbing Fire Protect System 8/30/1985 8/30/1990 Archived SSCALP'1640E 5 &SON CALL PLUMBING Construction Contractor Plumbing Fire Protect System 9/5/1984 8/30/1985 Archived Business Owner Information Name Role Effective Date Expiration Date FOWLER, STEVEN T B 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 6 LEXON INS CO 9800271 08/30/2009 Until Cancelled $12,000.0009/16 /2009 5 DEVELOPERS SURETY & INDEM CO 748001C 08/30/2007 Until Cancelled $12,000.0009/05 /2007 4 CBIC 658195 08/30/2001 08/30/2007 10/12/2009 $12,000.0009/10 /2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 19 NATIONWIDE MUTUAL INS CO ACPGL7852354529 08/30/2010 08/30/2011 $1,000,000.00 08/31/2010 18 NATIONWIDE MUTUAL INS CO ACPGL7832354529 08/30/2009 08/30/2010 $1,000,000.00 09/01/2009 17 NATIONWIDE MUTUAL INS CO ACPGL7812354529 08/30/2007 08/30/2009 $1,000,000.00 09/09/2008 16 NATIONWIDE MUTUAL INS CO ACPGL07511599155 08/30/2005 08/30/2007 $1,000,000.0008 /15/2006 15 NATIONWIDE MUTUAL INS CO ACPGL07501599155 08/30/2004 08/30/2005 $1,000,000.00 09/01/2004 14 SECURITY NATIONAL INS CO CPA05370300007 08/30/2003 08/30/2005 $1,000,000.0007 /26/2004 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 04/14/2011