Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL12-1065 - JC PENNEY
J C PENNEY 1249 SOUTHCENTER MALL EL12 -1065 City oOfukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov ELECTRICAL PERMIT Parcel No.: 2623049085 Address: 1249 SOUTHCENTER MALL TUKW Project Name: J C PENNEY Permit Number: EL12 -1065 Issue Date: 11/14/2012 Permit Expires On: 05/13/2013 Owner: Name: WEA SOUTHCENTER LLC BSIP Address: TOTAL 13 PARCEL NUMBERS , 2010 NEW PLAT MAJOR 920247 00000 Contact Person: Name: DAVE KAISER Address: 3104 C ST , AUBURN WA, 98366 Contractor: Name: E C COMPANY Address: P 0 BOX 10286 , PORTLAND OR 97296 Contractor License No: ECCOM ** 148BA Phone: 206 450 -7807 Phone: 503 - 224 -3511 Expiration Date: 06/30/2014 DESCRIPTION OF WORK: REMOVE DAMAGED BUSS DUCT AND INSTALL NEW CABLE TRAY AND FEEDERS FROM TRANSFORMER TO BUSS DUCT TAP BOX Value of Electrical: NRES: $30,000.00 RES: $0.00 Fees Collected: Type of Fire Protection: SPRINKLERS /AFA National Electrical Code Edition: Electrical service provided by: PUGET SOUND ENERGY Permit Center Authorized Signature: $760.63 2008 % V W Date: ( 1 1 4 1 I I hereby certify that I have read and : xami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie • with, hether specified herein or not. The granting of t permit oes no pries e to give authority to violate or cancel the provisions of any other state or local laws regulating construction r t e pert° c o work/ am authorized to sign and obtain this electrical permit. f Signature: Date: / ! / l/ 7/�,2- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: EL -4/10 EL12 -1065 Printed: 11 -14 -2012 • PERMIT CONDITIONS Permit No. EL 12 -1065 * *ELECTRICAL ** 1: A copy of the electrical work permit shall be posted or otherwise made readily accessible to the Electrical Inspector at each work site. 2: Approved plans shall be maintained at the construction site and shall be readily available to the Electrical Inspector. 3: All electrical work shall be in accordance with NFPA 70 - NEC, and requirements for electrical installations, Chapter 296 -46B WAC. 4: When any portion of the electrical installation is to be hidden from view by permanent placement of parts of the building, such equipment shall not be concealed until it has been inspected and approved by the Electrical Inspector. 5: The issuance of an electrical work permit shall not be construed to be a permit for, or an approval of, any violation of the provisions of the electrical code or other ordinances of the jurisdiction. Permits or related documentation that presumes to grant this authority are therefore not valid. 6: Any change in the scope of work described by the electrical work permit shall require additional work permits. Where approved plans have been issued, revisions to the plans and additional review may be required. doc: EL -4/10 EL12 -1065 Printed: 11 -14 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 •Southcenter Blvd., Suite 100 Tukwila, WAS 96168 hltp://www.ci.tukwila.wa.us Electrical Permit No. .e Project No. (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review: Applications will not be accepted through the mail or by fax: **Please .Print.** SITE LOCATION. Site Address: f 7-9 'Is 6) Tenant Name: r c_ 17,e4I'1 • 6 Property Owners Name:. W Si Mailing Address: P 0 t* King Co Assessor's Tax No.: Suite Number: Floor: 3 New Tenant: ❑ Yes. ..No. 2(I)2 — '\O- aftYlAf,Pme City CAA- State Zip CONTACT PERSON - Who do we contact when your permit is ready to be issued Name: C_ C<<QwLp1 — t .4 C,— Day Telephone: 26-.V-0 _ 7.. % —"gC 7 Mailing Address: 31 c9 Y e 4e, pp (,^�r.Lr't� (� 78 © ©2 City State Zip E -Mail Address: cu'' itep Fax Number: ELECTRICAL CONTRACTOR IiNFORMATION Company Name: P 6:10.4 p 4. Mailing Address: 3) D q e" g'C I¢N0 Contact Person: 144- iS �f E -Mail Address: �� ;� c e._- C — Contractor Registration Number: EC C/t%V *% I �� City State Zip Day Telephone: %pa TD Fax Number: Expiration Date: O1.l 17D Valuation of Project (contractor's bid.price): $ 3 ) L9 oeD Scope of Work (please provide detailed information): • 02e—Y►'t Di."-e_ �t�✓f't (� (� e•�� Lf_4 _zue_eJ Will service be altered? ❑ Yes tgi No PPn Type;of Use: Type of work: ❑ New ❑ Low Voltage Property Served by: g. Puget Sound Energy Seattle City Light ❑ Addition Generator Adding more than 50 amps? ❑ Yes ❑ No -S VAl~° ❑ Service Change ❑ Fire Alann H: Applications \Fonns•Applications On Line \4.2007 • Electrical Permit Application.doc bh Remodel ❑ Tenant Improvement ❑ Telecommunication ❑ Temporary Service Page 1 of 2 -RESIDENTIAL NEW RESIDENTIAL SERVICE. ❑ New single family dwellings. ( including an attached -garage) ❑ Garages,; pools, spas and outbuildings ❑ Low voltage systems. (alarm, furnace thermostat) $140.00 $75.00 ca $55.00. ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service, change or alteration 575.00 (no added/altered circuits) ❑ Service change with added/altered circuits 575.00 number of added circuits 510.00 ea ❑ Circuits added/altered without service change S50.00 (up to 5 circuits) ❑ Circuits added/altered without service change 550.00 (6 or more circuits) 57.00 ea ❑ Meter /mast repair 565.00 ❑ Low voltage systems $55.00 (alarm, furnace thermostat) PERMIT APPLICAT�O1VrNOTES MULTI- FAMILY AND COMMERCIAL Fees-are based .on the valuation of the electrical contract: MISCELLANEOUS FEES' ❑ Temporary service (residential)' $58.00 ❑ Temporary service (generator) $75.00 ❑ Manufactured /mobile home service 580.00 (excluding garage or outbuilding) ❑. Carnivals $75.00 Number of concessions 510.00 ea Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: St — Print Name: b g -0(� 6e—C,( Mailing Address: 3 E ( l'� 1�� Z -(,e b(.►�vL Dater j[ ' /3 Day Telephone: t -J,2 Date Application Accepted: kI I ('L I L City Date Application Expires: 98.0z State zip Staff Initials: I H: Applicationslorms- Applications On Line4-2007 - Bleariest Permit Applicatitin.doc: bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 2623049085 Permit Number: EL12 -1065 Address: 1249 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 11/13/2012 Applicant: J C PENNEY Issue Date: Receipt No.: R12 -03114 Payment Amount: $608.50 Initials: JEM Payment Date: 11/14/2012 12:40 PM User ID: 1165 Balance: $0.00 Payee: ROY HELLA, EC COMPANY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 014478 ACCOUNT ITEM LIST: Description 608.50 Account Code Current Pmts ELECTRICAL PERMIT - NONR 000.322.101.00.00 608.50 Total: $608.50 rinr-• Rar-aint_(1R - Printari• 11_14_2(117 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206-431-3665 Web site: http: / /www.TukwilaWA.gov RECEIPT ParcelNo.: 2623049085 Permit Number: EL12 -1065 Address: 1249 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 11/13/2012 Applicant: J C PENNEY Issue Date: Receipt No.: R12 -03087 Payment Amount: $152.13 Initials: JEM Payment Date: 11/13/2012 09:06 AM User ID: 1165 Balance: $608.50 Payee: DAVID W KAISER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd MC Authorization No. 070612 ACCOUNT ITEM LIST: Description 152.13 Account Code Current Pmts ELECTRICAL PLAN - NONRES 000.345.832.00.00 152.13 Total: $152.13 rinr.• Rarpint -OR Printari• 11 -11 -7017 INSPECTION ;RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 6ii io:c, CITY OF TUKWILA BUILDING DIVISION;.., 6300 Southcenter Blvd., #100, Tukwila: WA 98188 F-- (206)431 - ?6 Permit Inspection Request Line (206) 431 -2451 Project. � Type of Inspection: . Address: f7/ Date. Called: Special Instruction : 11 1 Not/ %Ai i 7111 r Date Wanted:. p. gy l ,: •m• n Requester: Phone No: f Approved per applicable codes. ElCorrections required prior to. approval. • COMMENTS: Inspector: 6 ie----- fritig Date: r n REINSPECTION FEE REQUIRED. Prior to next inspection.. fee. must be:' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. f. A 5 10 12 J C PENNY BUILDING SEPARATE PERMIT REQUIRED FOR LrV16chardcal ❑ Electrical cSumbing Gas Piping C`y of Tukwila S'y '- '!.N DIVISION SEATT ec 'ELECTRICAL CONSTRUCTION CO 3104 "C" STREET N.E., SUITE 200 AUBURN, WA 98002 PH: 800- 477 -1711 FIILE COPY !!Z0 • •t!3. t; . ly' !:,c: true on documents does not authct e 9 to; - _. �. 1� f: pted code or ,rdin3rtce. Rdc ;�t E ; �;,�; �� 4 rie:a Ccpy and conditions 's acknowIsd d: s DA-U / Date- EVi c1/4 Z City Of Tukwila BUILDING DIVISION LANE COBURN & ASSOCIATES ELECTRICAL !,SHEET INDEX . SHEET must. TITLE ISSUE FOR PERMIT 11,12/2012 E001 50.02 COVER Dial A DRAINING INDEX STLBDS LEGEND. ADDREVI0TONS AND GENERAL NOTES X ED 0.3 ETCH E102 FEEDER SCHEDULES /ND DALCULSTJOOS ELM VE ANCIC AILS I ONE {INE DUCA.W -REVISED X % X 12900 NE 180TH STREET, SUITE 201 BOTHELL, WA 98011 Main Office: 425 - 368 -4848 Fax: 425 -968 -9796 Manhattan, NY: 646- 580 -5221 Los Angeles, CA: 213- 375 -5221 www.lanecoburn.com TOTAL R EVIEWED FOR COMPLIANCE WITH NFPA70 -NEC NOV 13 2012 . covc City of-Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope cf boric without prior approval of Tukwila building Division. i . C + t-: vi cn, will require a new plan submittza End may in crude additional plan review fees. l CO EVIEWED COM P NO R LANCE ED 3 2012 City ofTu 3 `a ILDING DIVI ON RECEIV U CITY OF TUKWILA NOV 13 2012 PERMIT CENTER 4ELt21O cos OAKS 11 -16 --013 P.01150I StVOLD DATE A 7 9 10 12 SYMBOLS LEGEND - POWER SYMBOL PLAN DIAGRAM DESCRIPTION OT 65 $30 D1 T{ Q P34 otir tor C TRANSFORMER DELTA WYE 480Y/277V, 30, 4 -WIRE PANEL&kRD 208Y/120V, 30, 4 -WIRE PANELBO J40 EQUIPMENT CABINET - TYPE AS NOTED METER DIGITAL METERING UNIT CURRENT TRANSFORMER QUANTITY AND TARO AS INDICATED CIRCUIT BREAKER NUMBER INDMATES TRIP SETTING AND NUMBER OF POLES 0. - INDICATES CURRENT UNITING ST - INDICATES SHUNT TRIP DRAWOUT AC TYPE POWER CIRCUIT BREAKER BREAKER WITH EXTERNAL GROUND FAULT RELAY AND CT HIGH VOLTAGE CABLE TERMINATOR LA:HTNING ARRESTORS SURGE ARRESTORS FUSE WITH RATING MOTOR THERMAL OVERLOADS - (3) UNLESS OTHERWISE NOTED NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT 2- P0101101 SELECTOR SWITCH KEYED SECURITY SWITCH THERMOSTAT BATTERY SINGLE -POLE WALL SWITCH WALL SWITCH - SUBSCRIPT INDICATES LOWER CASE LEI 1 E INDICATES SWITCHING CROUP 2 2-POLE LV LOW - VOLTAGE 3 3-WAY OC OCCUPANCY SENSOR TYPE 4 4-WAY OP OCCUPANCY/PHOTOELECTRIC TYPE K KEYED WP WEATHERPROOF T TIME SWITCH MOTOR -RATED SWITCH - S1ZE OL PER MOTOR REQUIREMENTS MECL0NICAL EQUIPMENT EMERGENCY SHUTDOWN SWITCH EQUIPMENT CONNECTION GENERATOR MOTOR CONNECTION - SEE SCHEDULE FOR MOTOR DATA STARTER 3-POLE NEW SIZE 1 MINIMUM UNLESS 1103ED OTHERWISE COMBINATION STARTER RP RATED, 3-POLE NEIMA SEE 1 MINIMUM, UNLESS NOTED OTHERWISE - OVEiCIRRENT PROTECTION AS REQUIRED BY EQUIPMENT MANUFACTURER OR AS NOTED DISCONNECT SWOON 3-POLE UNLESS NOTED OTHERWISE FUSED DISCONNECT SNITCH 3-POLE UNLESS NOTED OTHERWISE - OVERCURRENT PROTECTION AS REQUIRED BY EQUIPMENT MANUFACTURER OR AS NOTED CONTACTOR SUBSCRIPT INDICATES NUMBER OF POLES MAY COLL CR-CONTROL RELAY: TD -TIME DELAY RELAY; LN -UNDE VOLTA£ RELAY; M -MOTOR CONTACTOR; RECEPTACLE - SUBSCRIPT INDICATES SUBSCRIPT NUMBER INDICATES CIRCUIT GROUPING 5 8505PT LETTER INDICATES: C- MOUNTED 6' ABOVE COUNTER LET - GROUND FAULT CIRCUIT HTRRUPLER - I0- 60LATED GROUND TYPE SP -SURGE PROTECTION TYPE WP- WEATHERPROOF XP- EXPLOSION PROOF GROUNDING TYPE SINGLE RECEPTACLE GROUNDING TYPE DUPLEX RECEPTACLE GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED 6• ABOVE COUNTER GROUNDING TYPE DOUBLE (*Po( RECEPTACLE GROUNDING TYPE DOUBLE DUPLD( RECEPTACLE MOUNTED 6' ABOVE COUNTER 000140-34004005804.0540004530031 SPUR WIRED GROUNDING TYPE DUPLEX RECEPTACLE SPECIAL PURPOSE RECEPTACLE - TYPE AS NOTED FLOOR BOX WITH FIRE/SMOKE RATED PENETRATION FLUSH WITH HIDED COVER UNLESS 011E1WI0E NOTED PEDESTAL- MOUNED DEVICES ON FLOOR BOX PONE -TH RU FITTING WITH 2-HIXUR FIRE/SMOKE RATED PENETRATION, WITH DEVICES AS INDICATED EQUIPMENT PUSHBUTTON SYMBOLS LEGEND - LIGHTING SYMBOL DIAGRAM DESCRIPTION I 00 ®1 164 0 2 LUMINAIRE ADJACENT NUMBER INDICATES CIRCUIT GROUPING LOWER CASE LEI IEf4 INDICATES 5WRa1WC GROUP RAMC INDICATES EGRESS UMR NI E ON EMERGENCY CROAT OR WITH BATTERY BACKUP BALLAST (IYPIMI) SURFACE 2x4 FLUORESCENT, TYPE AS NOTED SURFACE 144 FLUORESCENT, TYPE AS NOTED SURFACE 2,2 FLUORESCENT, T1PE AS NOTED RECESSED 2x4 FLUORESCENT. TYPE AS NOTED RECESSED 184 FWORESCENT, TYPE AS NOTED RECESSED 2T2 FLUORESCENT. TYPE AS NOTED PENDANT - MOUNTED LUMINAIRE TYPE AS NOTED WAN- MOUNTED FLUORESCENT LUMINAIRE. TYPE AS NOTED STRIP FLUORESCENT, TYPE AS NOTED STAGGERED -STRIP FLUORESCENT, TYPE AS NOTED DOWNUGHT OR CEIUNG- MOUNTED LUMINAIRE, TYPE AS NOTED WALL- MOUNTED LUMINAIRE TYPE AS NOTED WALL WASH LUMINAIRE TYPE AS NOTED DIRECTIONAL LUMINAIRE, TYPE AS NOTED TRACK LIGHT - LENGTH AS INDICATED NUMBER OF LUMINAIRES AS 1I VIN POE- MOUNTED LUMIN4IRE. TYPE AS NOTED 11.48301 OF LUMINAIRES AS SHOWN EXTERIOR LANDSCAPE LUMINAIRE, TYPE AS NOTED ILLUMINATED EXIT SIGN - SINGLE FACE ARROW INDICATES DIRECTION OF EGRESS ILLUMINATED MR SIGN - SINGLE FACE ARROW INDIGOES DIRECTION OF EGRESS BATTERY - POWERED EMERGENCY WAIPACK COMBINATION BATTERY POWEED EMERGENCY W3LIPAC( AND ILLUMINATED EXIT 9GN TIME CLOCK - TYPE AS NOTED UCHTHG CONTROL SYSTEM POWER PAC( ILLUMIN00N CONTROL STATION OCCUPANCY SENSOR PHOTOELECTRIC CONTROL CONTACTOR WITH NUMBER OF POLES SHOWN SYMBOLS LEGEND - COMMUNICATIONS SYMBOL DESCRIPTION RAN DIAGRAM 1A • TELEPHONE OUTLET 4D 4 COMPUTER /DATA OUTLET GW 4 COMBINATION V0CE/MTA OUTLET SUBSCRIPTS INDICATE A - COMPLIES W1111 ADA D - DESK -MOUNTED P - PAY PHONE W - WALL- MOUNTED QQ TELEVI90N JACK 5 SPEAKER 6 LOWER -.CASE LETTER INDICATES SWITCHING GROUP 0 SPEAKER - COUNG SURFACE- MOUNTED OS SPEAKER - CE.IUNG RECESSED-MOUNTED 0 SPEAKER - WALL SURFACE - MOUNTED 1® SPEAKER - WALL RECESSED - MOUNTED K E) CLOCK - WALL- MOUNTED ID INTERCOM - WALL MOUNTED SYMBOLS LEGEND - SECURITY SYMBOL RAN DIAGRAM DE3CRIPD)N ® WP ❑K WP OD WP P') azo E'P CARD READER WP INDICATES WEATHERPROOF KEYPAD WP O4DICATES WEATHERPROOF MOTION DETECTOR - INFRARED TYPE 0FCTRIC DOOR STRIKE DOOR/W8NDOW CONTACT CCTV CAMERA - FIXED TYPE WP INDICATES WEATHERPROOF CCTV CAMERA - PAN/TILT/ZOOM TYPE WP INDICATES WEATHERPROOF ALARM PUSHBUTTON P - INDICATES WITH PILOT LIMIT B10METR10 READER CARD (FADER W /BOMETRIC DEVICE HARMED EXIT DEVICE LIST OF ABBREVIATIONS ABBREVIATION DESCRIPTION ABBREVUTgN DESCRIPTION ABBREVIATOR DESCRmTON ABBREVIATION DESORPTION AC AF AFF AFG AIO APPROX ARCH AT ATS AUTO AWG BC BLDG BLOT BIAS CAT OCT CB CLG CO COL COMA CONN CP CPT CS CT CU DC DED CET DA DISC SC DMu DWG EA EL ELEC ELEV EMERG EMT ENCL EOL EPR EOUP ERIC EWH EIN EXIST OR LE) EAT AMMETER. AMPERE OR AMP* ALTERNATWG CURRENT MP FRAME WE FMSIED FLOOR ABOVE FMSHED GRADE MPS INTERRUPTING CURRENT APPROAAATELY ARCCIURAL AMP TRIP AUT0ILAATIC TRANSFER SWITCH AUTOMATIC AMERICAN WIRE GAGE BARE COPPER BUILD. BREAKER BUILDING MANAGEMENT SYSTEM CONDUIT OR CENTIGRADE CATALOG CRCUT BREAKER CIRCUIT CEN NG CONDUIT ONLY WITH PULL STRING COLUMN CWMUNIGTONS CONNECTOR CONNECTION CONTROL PANEL CONTROL POWER TRANSFORMER CONTROL STATION CURRENT TRANSFORMER COPPER DIRECT CURRENT DEDICATED DETAIL DIAMETER DIMENSION DISCONNECT °GOAL METERING UNIT DOWN DRAWING EACH ELEVATION (HEIGHT) ELECTRICAL ELEVATOR(VEw) EMERGENCY ELECTRICAL METALLIC NENG ENCLOSURE ENOOF-UNE DEVIE ETHYLENE PROPYLENE RUBBER EQUIPMENT ELECTRIC wATER COOLER ELECTRIC WATER HEATER EAMUST EXISTING EXTERIOR FAHRENHEIT FA FBO FC FCP FON FDR FLAP FN FLR FUT FLA FLEX FLR FLUOR FT FUT GOR CND GA CALV GEN GFI GRS HN HO UDR¢ HP HPS HT NTR SE ICS ro OF LB LAST NSTR JD. JBOX WA EVAR N ANHD LED LS LTG LTS LV M OR MTR MAn FIRE ALARM FUNRSHED BY OWNER OR OTHERS FOOTCANDLE FRE ALARM CONTROL PANEL FOUNDATION FEEDER FRACTKOAL HORSEPOWER FINISHED FLOOR FONRE FULL LOAD AMPERES FLEXIBLE COND. FLOOR FLUORESCENT FOOT OR FEET FUTURE GROUND GAUGE GALVAMEEO GENERATOR GROUND FAULT CRCUT INTERRUPTER GALVANIZED RIGID STEEL NANISHOLE HIGH LATE NSm DISONRGE HORIZONTAL H ORSEPONER WGHH PRESSURE SODIUM HEIGHT HEATER CURRENT INSTALLED/CONNECTED BY ELECTRICAL INSTALLED BY OTHERS INTERRURTNG CAPAOIY LL W NATION CONTROL STATION INSIDE DIAMETER INTERMEDIATE CSTRRUTON FRAME NSTR WENT JUNCTION BOX NCH CR INDIES INSTANTANEOUS N STRWENT .UNCTION BOX THOUSAND THOUSAND CRDAAR MILS KILOVOLT KILOVOLT AMPERES KILOVOLT AMPERES REACTIVE ICILOWArIS KILOWATT HOURS KILOWATT HOUR DEMAND LIGHT EMOTING DIODE LMT SWITCH LIGHTING LIGHTS LOW VOLTAGE MOTOR M FERAL MAX MCA MC MCC MCP MDGF MECH MEE MG MH MN MSC MLO MOCPD MTD NITS NC NEC NEM A NI NO. NO NTS OC CFO OL OPNG PA PB PBX PF PH PKG PLCS PLAN PO PR PRI T Pv C POUR OTT REC REOX REV RM RPM RS MAWAUM NM W ORO. AMPACT' METAL CUD CABLE MOTOR CONTROL CENTER N DISTRIBUTION FRAME ODYED DIFFERENTIAL GROUND FAULT • MECHANICAL MANUFACTURER MOTOR GENERATOR MANHOLE MINIMUM MISCELLANEOUS MAN LUGS ONLY MAXMW OVERCURRE NT PROTECTIVE DEVICE DLNTED MANUAL TRANSFER SWITCH ORAL NORMALLY CLOSED NATIONAL ELECTRICAL CODE NATURAL ELECTMCAL MANUFACTURERS ASSOCWTON NOT IN CONTRACT NIGHT NI LIGHT NUMBER NORMALLY OPEN NOT TO SCALE ONCE R OUTSIDE DIAMETER NNEIL FURNISHED CONTRACTOR STALLED OVERLOADS °PENN. POLE • PUBLIC ADDRESS PULLBOX PRIVATE BRANCH EXCHANGE POWER FACTOR PNUSE PACKAGE PLACES PANEL OR PANELBOARD POWER DUALITY PAR PRMARY POTENTWI TRANSFORMER POLYVINYL CHLORIDE PONER OuANTITY RESISTANCE OR RADIUS RECEPTACLE REOPRED REVISOR ROOM REVOLUTIONS PER MINUTE RAPE) START SCHED SEC SECT SILO SPEC C SD SS ST STD SR STRRR STRUCT SV SVC SW SWBD SYNC SYS 113 1D TEMP TERM THD THHN TARN SCHEDULE SECONDARY SECTION sHEL1 OR SHIELDED SHEET SPECEICATON(5) SOARS STAINLESS STEEL SHUT TRIP STANDARD STEEL STARTER STRUCTURAL SOLENOID VALVE SERVICE SWITCH SWYTOGOARD SYMMETRICAL SYNCHRONOUS SYSTEM TERMINAL BLOCK TIME DELAY TELEPHONE TEMPERATURE OA TEMPORARY • TERMINAL TOTAL HARMONIC DISTORTION HEATRESISTANT THERNICIPLASTG MT1IERM EAIAHEAT RESISTANT THERMOPUSTC TOMOF STEEL OR SUPPORT ER SWITCH TWISTEOSHHELDED PAN TELEPHONE TERMINAL BOARD TELEPHONE TERMINAL CABINET TYPICAL UNDER-COUNTER UNDERFLOOR UNDERGROUND UNDERWRITER LABORATORIES UNLESS OTHERWISE NOTED UNNTERRUPTABLE POWER SUPPLY UNSHiELDED TASTED PAR VOLTS VOLTMETER WATTS OR wIRE WITH WR1 M T OLD OUT WEATHERPROOF REACTANCE TRANSFORMER MOSTURETAND HEATAF SSTANT CROSS -LINK ED SYNTHETIC POLYMER CROSS.UNKED POLYETHYLENE EXPLOSION PROOF IMPEDANCE SYMBOLS LEGEND - FIRE ALARM SYMBOLS LEGEND - GENERAL REFERENCE SYMBOL LEGEND SYMBOL RAN D4GRA4 DESCRIPI)0N ICI L1 ❑Ts I PR' I X30 El 0 O 0 cv Ka FIRE ADAM SYSTEM CONTROL PANEL ESR - ELEVATOR STATUS/RECALL FA0 - FIRE ALARM COMMUNICATOR FCP - FIFE ALARM CONTROL PNEL FSA - FIE SYSTEM ANNUNCIATOR HCP - HOLON CONTROL PANEL_ HVA - HVAC OR EXF4UST STAIRWELL PRESSURIZATION FIE ALARM FUDW SWITCH . FIRE ALARM PRESSURE SWITCH FIRE ALARM TAMPER SWITCH POST INDICTOR VALVE FIRE ALARM PULL STATION FIRE ALARM STROBE FIRE HARM HORN -STROBE NUMBER INDICATES CANDEILA RAMC FIE FIGHTER PHONE JACK HEAT DETECTOR F - FIXED TEMPERATURE R - RATE OF RISE ONLY R/C - RATE COMPENSATION R/F - RATE OF RISE AND FDTD TEAIPERAIURE SMOKE DETECTOR BT - 8FAM TRANSMITTER BR - BEAM RECEIVER L - IONIZATION P - PHOTOELECTRIC FIRE ALARM SMOKE DETECTOR DUCT - MOUNTED WITH TUBE FLAME DETECTOR GAS DETECTOR ALARM LIGHT A- ALARM; B- BEACON; F-FIRE; R-- REMOTE 0-SECURITY LOWER -CASE LETTER INDICATES SWITCHING GROUP ALARM BUZZER A- 301908 ; F -FIRE; 5- SECURITY ALARM BELL A -HARM; F -FIRE 5- SECURITY ALARM HORN GRIM CHBME A- ALARM; F -FIRE; 5- SECURITY SYMBOL PLAN DIAGRAM DESCRIPTION —G- -IV — AMP —H CONDUIT - CONCEALED IN CONSTRUCTION IN FINSHED AREAS, EXPOSED IN UNFINISHED AREAS CONDUIT - CONCEALED IN OR UNDER FLOOR OR ROUTED UNDERGROUND GROUND WIRE LOW- VOLTAGE WIRING (CLASS B) EXISTING TO BE REMOVED (CROSS- HATD1ED) HEAVY UNEVWE7GIT INDICATES NEW WOW LIGHT UNEW0GHT INDICATES MISTING INFORMATION CONDUIT OR CABLE TURNING DOWN CONDOR OR CABLE TURNING UP CONDUIT STUB - TERMINATE WITH BUSHING OR CAP F 1311440400110 CONDUIT SEAL RDA' CONDUIT HOME RUN - NUMBER OF CONDUCTORS AS INDICTED SMALL HASH MARKS 84005TE PHASE CONDUCTORS LARGER HASH MARK INIDCATES NEUTRAL BACKSLASH INDICATES EQUIPMENT GROUND BACKSLASH WITH DOT INDICATES ISOLATED GROUND ALL UNMARKED CONDUIT RUNS ARE 1/2' CONDUIT WITH 2 112, 1 #12 OND UNLESS OTHERWISE NOTED CONDUCTORS - CONNECTED CONDUCTORS - NOT CONNECTED JUNCTION BOX PULLBOX - STZE AS INDICATED OR AS REQUIRED BY CODE HADHOLE WITH DESIGNATION 40NFIOLE 4T1H DESIGNATION SYMBOL DESCRIPTION DD F <C122) DENT SYMBOL A- IDENTIFYING NUMBER 13-MEET WHERE DETAIL IS TAICFIN C -SHEET WHERE DETAIL IS SHOWN SECTION OR ELEVATION SYM A- IDENTIFYING NUMBER 13-SHEET WHERE SU,UON IS 73)003N C -SHEET WHERE SECTION IS SHOWN NORM ARROW TRUE NORM AND BU 10810 NORM AS HOICKED SHEET NOTE TAG SYMBOL A - NOTE NUMBER LIGHTING FIXTURE IDENTIFICATION POWER RACEWAY /CABLE IDENTIFICATION CONTROL RACEWAY IDE TECATI)N CONTROL DIAGRAM NUMBER REFERENCE PH0T0 NUMBER AND DIRECTION REVISION SYMBOL REVIEWED FOR COMPLIANCE WITH NFPA70 -NEC 3 2012 SYMBOLS LEGEND - GROUNDING SYMBOL DESCRIPTION NOV PLAN DIAGRAM L GROUND CONNECTION HII --{U GROUND ROD 0-11) 0-0 MOUND WELL ■ City 01 BUILDING DIVISION PROJECT GENERAL NOTES: 1. SYMBOLS SHOWN W THE LEGEND ARE TYPICAL NOT ALL SYMBOLS MAY APPLY TO THIS PROJECT. 2. CONDITIONS SHOWN ON DOCUMENTS WERE TAKEN FROM AV3ILABLE RECORD DOCUMENT INFORMATION AND FIELD INVESIX'ARON. TFIE CONTRACTOR SEWN LOCATE AND VERIFY AIL ELECTRICAL SYSTEMS WHIN 174E IDENTIFIED AREAS PRIOR TO STARTING ANY WORK. ANY DISCREPANCIES BETWEEN INFORMATION SHOWN AND ACTUAL CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 3. PROVIDE ALL 344TERAS, LABOR AND EQUIPMENT REOUWFD FOR A COMPLETE AND OPERATIONAL INSTALLATION. MATERIALS AND WORKMANSHIP SHALL FULLY COMPLY WITH THE REQUIREMENTS OF 1110 LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE THE INTERNATIONAL BUILDING CODE AND THE LAWS AND REGULATIONS 04 114E STATE OF VIRGINIA. 4. ALL CONTROLS AND SWITCHES INTENDED TO BE USED BY THE OCCUPANT OF THE ROOM OR AREA TO CONTROL LIGHTING AND RECEPTACLE OUTLETS, APPU4HCE5 OR COOLING. HEATING AND VENTILATING EQUIPMENT. 9LN1 BE LOCATED NO MORE THAN 481140HES MEASURED ER04 THE TOP OF THE JUNCTION OR DEVICE BOX NOR IF55 RAN 15 INDIES MEASURED TO THE BOTTOM OF THE JUNCTION OR DEVICE BOX ABOVE THE FINISHED FLOOR. 5. LIGHTING FIXTURES INSTALLED H A SUSPENDED MANG SHALL BE FASTENED TO THE CEILING FRAMING MEMBER AT ALL FOUR CORNERS WITH SCREWS AND ATTACHED 340.12 CEILING WIRES TO PILE 11GITING FIXTURES AT DIAGONALLY OPPOSITE CORNERS AND TO THE STRUCTURAL CEILING. 6. WHERE MORE TEAK ONE NOMINAL VOLTAGE 0151DI EXISTS IN A RAIDING, EACH UNGROUNDED SYSTEM CONDUCTOR SHAM BE IDENTIFIED BY PHASE AND SYSTEM. THE MEANS OF IDENTIFICATION SHALL BE PERMANENTLY POSTED AT EACH BRANCH CIRCUIT PANELBO4RtD. THE PHASE COLOR 000140 OF THE INSULATION OF CONDUCTORS SHELL BE: D) BROWN- ORNIGE- YELLOW. FOR 480/277 VOLTS. b) BLAOK -OED -BLUE FOR 2087/120 VOLTS. 7. PER THE CONSTRUCTION CODE THE MEANS OF EGRESS ILLUMINATION LEVEL SHALL NOT BE LESS TWIN 1 FOOT - CANDLE (11 LUX) AT THE WAIXUNG SURFACE LEVE7... IN THE EVEN OF POWER SUPPLY FAILURE AN EMERGENCY ELEC1PJGL SYSTEM SR4L1. AUTOMATICALLY ILLUMINATE THE FOLLOWING AREAS: 1) AIRES AND UNENCLDSED EGRESS STAIRWAYS IN ROOMS AND SPACES THAT REQUIRE TWO OR MORE MEANS OF 2) CORRIDORS. EXIT ENCLOSURES AND EXIT PASSAGEWAYS IN BUILDINGS REWIRED TO HAVE TURD OR MORE EXITS. 3) COMM EGRESS COMPONENTS AT OTHER THAN THE LEVEL OF EDT DISCHARGE UNTIL EXIT DISCHARGE IS ACWMPUSNED FOR BUILDINGS REWIRED TO RAVE TWO OR MORE DOTS 4) INTERIOR DOT DISCHARGE ODORS. AS PERMITTED IN SECTION 1024.1, IN BUILDINGS REQUIRED TO RAVE TWO OR MORE EXSS. 5) DRERIOR LANDINGS, AS REQUIRED BY I.C.C. SECTION 1008.1.5, FOR DOT DISCHARGE DOORWAYS IN 83083405 REQUIRED TO NAVE TWO OR MORE DOTS. THE EMERGENCY POWER STSEM SHALL PROVIDE POWER FOR DURATION OF NOT LESS THAN 90 MINUTES AND SHALL CONSIST OF STORAGE 84TTE8ES. UNIT EQUIPMENT OR AN ON -SITE GENERATOR REVIEWED FOR • E COMPLI CE PRO NOV a 2012 Ity of Tu B LDING DIVIS N RECEtVLO CITY OF TUKWILA NOV 13 2012 PERMIT CENTER DAPS 11- 14-2013 T Z z W 6 v 8 ISSUE VTR EVSED DATE MOTOR 001477.1 0105 HP I A 7 9 10 .1 12 TYPE 3 PHASE PM 3- PHASE FAULT CURRENT CALCULATIONS (POINT -TO -POINT METHOD) UTN.RY TRANSFORMER DATA 1 4 4 13 8 1-A .. F. PLDRN� 1.. NOMINAL VALUE FUN AVA8AOL0 4/414: (34000 Ni (AFL)15 00500 UN UTILITY COMPANY 56rt IXAF. ITV COMPANY DATA - .X190 13 �XR ..110 • MOTOR CONTRIBUTION IS TIMES TE R0.5NC CURRENT. BASED ON 1 40003' NEW FEEDER •2247 AM F 0111T 010147450.011111 ITS 2t. 443422 L.440,0 NODE NODE NAME PREVIOUS DISTANCE VOLTAGE CODE 02700.3) CONDUCTORS UMBER PHASE ALUMINUM OF SE15 CONDUCTORS OR COP. SIZE RILCWOY TYPE MAG.71C OR ET1C 014701 CJ0T 51340331 WITH MOTOR CONTRIBUTION c/0 111IIL.TMRRO RATIO ( E 0/00 .l,3M A R. VOA 8 19 MAN SERVICE 1 30 .0 6 404444 CU N/A MAC NOTES: 1. 7./0 CALCULATIONS ARE PERFORMED DIN A PERJIMT34S15. THE SASE kVA 15 1000 THE BASE VOLTAGE IS 40, THE BASE IMPEDANCE 15 02304 01145 2. SERE 5 RATED EO090ME NT SHALL BE PROVIDED N ACCORDANCE WITH NEC. SERIESIUIED CO2021011045 SHALL BE LISTED SY UNDERWRITERS LABORATORIES. 3. NEC TABLE 9 05310ES 065 POWER FACTOR FOR DETERMINATION OP CIRCUIT VOLTAGE DROP. 41AXM00 LOAD 13 ASSUMED TO BE 0.6 OF OVERCURRENTPROTECTNE DEVICE. TESTED FACTOR R 00 ADJUSTED EOPT AIC RATING (441440 Vl.I TIPS 01'1...(3 VON I EC 84VO TABLE S. NUMBER 7 DO 0 IAN NAME 04AIN 3.4.0 PAN. 3 -PHASE FAULT CURRENT CALCULATIONS (POINT -TO -POINT METHOD) UTILITY TRANSFORMER DATA . UTILITY COMPANY W T. TYPE VOYAGE kVA 3 PHASE w 277 [ AFC I MPEDANCE I XR RATIO • NOMINAL VALUE FOR AVAILABLE FAULT CURRENT (AFC)* BASED ON UTILITY COMPANY SCHEDULE AFC I IMPEDANCE I X10 RA TO 49,229.0 7.3 I ID '3 PROVOE0 BY THE MTV COMPANY MOTOR CONTRIBUTION NP 200 • MOTOR CONTRIBUTOR IS 510425 TIE RUNNING CURRENT. BASED ON 1 0V6711 OLD FEEDER WIRE CODE AVAILABLE FAULT CURRENT FROM UTILITY AT: A RMS SWI NODE NODE NAME PREVIOUS DISTANCE VOLTAGE NO. NODE RACEWAY NUMBER OF SETS CONDUCTORS PRASE ALUMINUM CONDUCTORS OR COPPER 512E BTIWAY E MAGNETIC OR SHORT CNT CURRENT WITH MOTOR CONTRIBUTION X/R ADJUSTMENTS 8/03 a DJUST.. ADJUSTED RATIO TESTED FACTOR A RMS EOPT AIC Ram. FEEDER VOLTAGE DROP WIRE OM • S NEC TABLE B *VD mDL, NUMBER NODE 3000 MAN SERVICE PANEL .0 FEEDER CU BUSS 50,266 a RMS SYM 9.0 1.129 •56,,33 65 kAIC 6010 3,003 NIA NIA 2 M01M SERVICE PANEL NOTES: 1. Y1R CALCULATORS ARE PERFORMED ON A PER -UNIT 68513. THE SASE OVA IS 100, THE BASE VOLT GE (5 460, THE 5450 51PEDANCE (5 0.2304 OHMS 2. SERIES RATED 40131 -84051 SHALL BE PROVIDED N ACCORDANCE WON NEC. 5ERE5 RATED COMBNATWNS SHALL BE LISTED BY UNDERWRITERS LABORATORIES. 3. NEC TABLE 9 ASSUMES 0.65 POWER FACTOR FON 13E 1E1.044NAI1CN 01 °RCIIIT VOLTAGE DROP. 245.0000, LOAD (5 ASSUMED TO SE 8014 OF OVERCURRENT PROTECTNE DEVICE. FEEDER AND BRANCH CIRCUIT SCHEDULE 98- 0EDREE C ALUMINIJSCOVP. ORCDIT TAG (NOTE 1) DCPD (NOTE 2) WIRE " MPS (NOTE 3) 0GEWAY CO013 S .70 PER SET SETS S.(NOTE EMT 4) M A UM PHASE CONDUCTORS CO(3)600 NEUTRAL CONDUCTOR GROUND (NOTES) 400024 4000 4060 2 ! 44.5 (17600 08.11 39400 4804 400243 4020 4080 2 3-147 3-1)0' (3)60080* 3)40040. 35004 3500 3740 1 C (39000 0403 (1}004041 (2)4004003 350043 3500 3740 1 3-117 3-117 (6}600 40.14 017400 4444 30044 350 3060 3-1/7 C (3)6004041 (1 )-6000.4 09600 4048 30023 300 3050 3 3.117 (3}600440:4 (1)00000.4 25004 250 2720 3-1/7 4. (3}50046.4 (1760211.4 (1)6040 250163 2500 2720 3- 3-10' (3)60040.. (1)604444 243 00 320 200 2040 2040 3.17 3.Y r 0 4* (3)6 kc (3)600 kc.* (1)60 00003 (17400411 .4 (1.00 0004 162034 1600 1700 3-107 (3)604001 (1)600kc44 (19350 4004 160063 100 170 3 3-1/7 (3)60kc (1 )-350000 15014 1550 T 3-107' (3}62040.4 (1}50040.4 (1}350 01103 150503 15014 1550 3' (3)-5000041 ) (1 }3500004 13050 13014 1360 3-1/1 41 (3)60000 (1 }00 3004 (1)-350 400 13003 1360 3 3_1/7 (3760060* (1}350 k0+44 12000 1200 1240 3- 3.17 (39500 004 (1 }5046021 (1}250404* 12003 120 1240 3 (3}504001 (1}2501004 10004 1003 105 7 3 (3740 003 (1}42046.3 (1)420 10044 1002 1020 3.1/7 3-1/7 (3)60 2004 (1 }404004 (1}4470 100 0 1220 8 1020 810 3' 3 -17' 3 (37600 4004 (3)400402 (1)42000.4 (1)440 (1 )430 800,0.3 800 512 2 -1/7 2.17 094224440 (1}030 70004 700 750 2 -172' 2 -17 P )45040.4 (1)3504000 7003 700 750 2 -1/2' 2.1? (3)3504444 (1)9310 6204 ' 60 6220 3 3-0/7 (3)50 4604 (1 }501 404.4 (1}020 5004 0 3 64 60 6 0 620 620 3 3 3' 3 (3)00404 (3)501004 (1}504003 (1)4210 (1)420 50 500 2 2.13' 3 (3)3301004 (19350 4063 (1 )41/0 50 50 2 -110' 2 -1447 (3}352 4044 (1)410 45004 450 460 2 2 -1/7 2.12• (3}32244.* (1)3023004 (1.10 5043 450 460 2 2 -17 2 -17 0 }30840.6 (1.175 40044 400 410 2 31/' 3-177 0}2504.4 (1)2504004 (1991 40043 440 A10 2 2.117 (3)25040.44 (1(41/0 3004 350 30 2 2 -175 2 -1/7 (3)440 (3)4410 (1.1 3 � 3 0 300 360 310 2 7 3 r 312' 0)44/0 2)60210.8 (17500044 (1)41 (1 (41 30043 300 310 2.1/7 3 (3)600 0604 (1981 20 210 3 3 0.003004 (174040.8 (1.2 25003 250 270 2 -1/7 3 09422 4004 (1.2 225442' 45 04 225 225 240 2 r 2 -12' r 3 (3 )410 (3)-3004044 (1)41/0 (1)3000000 (1.2 (1)42 4543 225 730 2 -1/7 2 -1(7 (3)30 4604 I (1 )42 450 225 240 2 -1/7 2.127 (3}040 (1)000 (1)94 2004 200 205 2.112. 2 -12- (3}250 00* (1}2508044 (1.2 30003 20 205 r 2 -12' (39250 104741 (1.2 17504 175 160 2 -17 2 -1121 (37540 (1)6820 (1)44 1703 175 7 (3.40 1 0.4 15004 15 63 150 150 155 155 7 7 7 09830 (3.320 (1)03/0 (1(44 (1.4 12504 125 135 T 7 14.20 (1)120 (1)44 12543 125 135 1.117 r (39920 1 0.4 110A4 110 120 7 r (3)41/2 (1)41 /0 (1}24 11063 110 11D 1.107 1.1/7 0 )410 / (1.4 120 10D 1 -17 1.1/7 0.1 (1)81 (3)95 10043 100 1-12' (3.1 (1}06 004 0 103 1 -124- 1 -1/4' (3.3 (1)53 (1)66 00 0 10 1 -1(3' (3.3 ((.S 800 0 SS 14. 910. (3(44 (1)04 (1)48 8003 50 35 1/ 1 -tw' 2)44 (1)48 7008 70 65 1' (3)44 (1)44 M. 700 A 65 3/f (3)04 (1908 600 60 55 (3)45 (1)46 (1)410 00 60 65 Sf 14.6 (1 )410 5003 0 0 of (1(46 500 50 0 S4' 3/4. (3)43 (1.10 450 45 50 VC P.8 (1735 (1 )410 4503 45 50 Yr of (3}68 (19810 40 50 ar P.8 (1)08 (1 )410 400 40 50 VC Sr 0988 (1)410 350 no 35 35 50 s2 3.4- Sf t- Sr (3)48 14).a6 01.11 I 0(410 (17110 3004 30 30 /7 Sr 147.0 (1)410 (1.10 300 30 30 17 1/7 2.10 (1 )410 75 30 1)7 of 14.12 (1(412 (1.10 250 25 30 1(7 1/7 O.10 (1761D 2004 20 20 1/7 1/7 (3.12 (1)412 (1)412 200 25 20 1(7 1/7 (3)412 (1.12 1504' 15 20 VT _.' Ur 0 )412 '(1 (4(2 09912 - 150 15 20 117 1(7 (3)412 (1}012 GENERA NOTES 1. CIRCUIT T5G NDICATESFEEDER OCP02W5. CONDUCTOR MATERIAL (A. ALUMINUM C 4 COP ER). MP NUMBER 00 CONOUCTORSBSCLUDNG GROUND) EOUP3331GROUNDING CONDUCTORS ARE 544E W(ER2 AS 14345E CONDUCTORS. 2. WS. REPRESENTS THE 44244UM DURRENT DESIGN MPS AND... ON NEC TABLE 312 - 160110 5020500120 FAC3DIR5 FOR TEWERATU5E OR 3 545200 . SIZED TO INCLUDE IN EOUPOENT GRO/NDNG CONDUC1 OR, 71400340.5800381 051 SE UTILIZED AS EQUIPMENT GROUND PER NEC 250-118. 01ER0 C011N1.01.13 301ALLC R3CE01IS 001012 ®. PROVOE EDUPOENT GROUND,. CONDUCTOR. ' 275260SED WM.. CONDUIT, SCHEDULE 60. 5. 003207 ANDWIRE MAYBE REPLACEDVJTHI NC CABLE 6. STAMD2RD OVERCURRENT PROTECTNEDEVCE ...PER NEC 2404 ' ASSLNESADJUSTA13.1RP CRCUR BREAKER 7. UNCERG5OLND 233044TOR5 SNLLL BE 331-1262. 8. ABOVE GROUND CODUCTORS5HAII BE 17WN/MWN OR 33555 -2. GENERAL NOTES: 1. BASED ON THE ABOVE CALCULATION THE NEW WIRE SYSTEM PROVIDES A LOWER FAULT CURRENT AT THE EXISTING SWRCHGEAR. ADDITIONALLY A 20000 CURRENT UMTNNG FUSE 5 REPLACING A 3000A CURRENT UMNING FUSE REVIEWED Q PA7ObNEC NOV 13 2012 City ot.Tukwila BUILDING DIVISION EVIEWED F COMP ANCE R ED NOV 2012 ity of Tukwila B ILDING DIVISIO RECEi'J tL) CITY OF TUK`1'LA NOV 13 2012 PERMIT CENTER E401 11 -I0 -0013 ; LU Q Z Z Z ? W - W O O 4 037 ~Q m O lu 5n � PROTECT 612169 332E01 REVISED OAT 2 3 5 6 B t0 IZ TYP DOSTING BUS DUCT EXTENDED TO PSE VAULT 11? EXISTING BUS DUCT EXTENDED TO PSE VAULT (40004 1E41N TYP • PLAN VIEW - NEW SCALE NONE 2' 1 20044 14NN 88 88 88 BR 88 88 B8 '400 krm8 (TYP) __/( .4. •• .4. .4. .. DETAIL NEF CABLE TRAY SCALE NONE GENERAL NOTES: 1. TH5 PROJECT CONSISTS OF REPLACING A SHORT RUN OF THE EESMC (2) 3000 A ALUMINUM BUS DUCTS 05IDE THE PSE TRANSFORMER VAULT WITH (6) SETS OF 400 koni COPPER CONDUCTORS AND REPLACING THE 3.000 A CURRENT M11140 FUSES WITH 2,000 A CURRENT LIMITING FUSES OILY. THE 2.000 A COPPER C'ABIos HAVE A HBU4ERR IMPEDANCE 114N! THE BUS DUCT RESULT IN A LOWER FAULT CURRENT AT THE EXISTING S15110400615. AS THIS SCOPE DOES NOT PICUJDE REPLACING ANY OF THE atom PSE TRANSFORMERS AND THE RESULTING FAULT CURRENT SHOLRD BE LESS 110N CURRENT CONDITIONS, A FAULT CURRENT STUDY FOR THE PROJECT INS NOT BEEN COMPLETED. REFERENCE NOTES: 12> 24 INCH CABLE TRAY. PROVIDE SUPPORT FOR 140 POUNDS PER FOOT. PROVIDE SEISMIC BRACING AS REQUIRED. PROVIDE FIRE STOP PER PSE STANDARD. REVIEWED FOR COMPLIANCE WITH NPPA 70 s NEC NOV 13 2012 City of Tukwila BUILDING DIVISION REVIEWED FOR C• •E COMM%• CE PROV NOV 2012 B of TukWil DING DIVISIO RECtovcu CITY OF TUKvvIA NOV 13 2012 PERMIT CENTER EXPIRES 11- 16-3113 BASED ON INFORMATION FROM LUKE NEEDY (PSE) THE PEAK METERED LOAD FOR THIS TRANSFORMER VAULT IS 870 KVA = 10484 0 15)0 KVA 7.33X Z 12.47/480 1500 KVA 7.33X Z 17.47/480 480V, 3 PHASE UTILIZING THE RETAIIREO 125X PER THE NEC ON PEAK DEMAND METERING, THE PEAK EXISTING LOAD IS ONLY 13084 TYP DOSTING BUS DUCT EXTENDED TO PSE VAULT 11? EXISTING BUS DUCT EXTENDED TO PSE VAULT (40004 1E41N TYP • PLAN VIEW - NEW SCALE NONE 2' 1 20044 14NN 88 88 88 BR 88 88 B8 '400 krm8 (TYP) __/( .4. •• .4. .4. .. DETAIL NEF CABLE TRAY SCALE NONE GENERAL NOTES: 1. TH5 PROJECT CONSISTS OF REPLACING A SHORT RUN OF THE EESMC (2) 3000 A ALUMINUM BUS DUCTS 05IDE THE PSE TRANSFORMER VAULT WITH (6) SETS OF 400 koni COPPER CONDUCTORS AND REPLACING THE 3.000 A CURRENT M11140 FUSES WITH 2,000 A CURRENT LIMITING FUSES OILY. THE 2.000 A COPPER C'ABIos HAVE A HBU4ERR IMPEDANCE 114N! THE BUS DUCT RESULT IN A LOWER FAULT CURRENT AT THE EXISTING S15110400615. AS THIS SCOPE DOES NOT PICUJDE REPLACING ANY OF THE atom PSE TRANSFORMERS AND THE RESULTING FAULT CURRENT SHOLRD BE LESS 110N CURRENT CONDITIONS, A FAULT CURRENT STUDY FOR THE PROJECT INS NOT BEEN COMPLETED. REFERENCE NOTES: 12> 24 INCH CABLE TRAY. PROVIDE SUPPORT FOR 140 POUNDS PER FOOT. PROVIDE SEISMIC BRACING AS REQUIRED. PROVIDE FIRE STOP PER PSE STANDARD. REVIEWED FOR COMPLIANCE WITH NPPA 70 s NEC NOV 13 2012 City of Tukwila BUILDING DIVISION REVIEWED FOR C• •E COMM%• CE PROV NOV 2012 B of TukWil DING DIVISIO RECtovcu CITY OF TUKvvIA NOV 13 2012 PERMIT CENTER EXPIRES 11- 16-3113 7 10 12 LOW -PEAK* Time -Delay Fuses Ctxs L - 600 Volt EXISTING BUS DUCT EXTENDED TO PSE VAULT EXISTING BUS DUCT EXTENDED TO PSE VAULT 60006 BUS ONE -LINE DIAGRAM - EXISTING SCALE NONE KRP-C 2001.0000A t_. .0...a 1000_a0 note* -4 vordt l!*t N. Snl. OMw1.d Mots Olio E@I 0010A+N6 er.. me`- 000 vu AC RIO& em...0.� n■.c 9.306 i066 6 pa) .. P.. c.d.Fi6t iES6l2 470.0r060 5100000•1a. 104.. Ee WV/ O.616.667.O.00.06 0.60 6060 6.6 Ammon. 0.0.00 a61to•lat NOM Ono, trees. • Moo 016600 Ow b 6001066060 tivloui 090000tr MP COCO 001070 Pare e 6WO* ,70066 1610661 loom. 0 m i O a60 • 060.6006 Om et overa6 6.6 0666 • DbrWO 610 daccuoo 6000=. - 0660.1 WC Sedva109n >'.66101066 060 00000. bpc 01:1 woe 16 0.66 • HO 066 06061116 66616 ounoeai Dee 00666166010x'00609 Ed. uo treta0._ • 9sv6o 6 n Or 666616 b6.. maw 660o laima..e 0 nto 0061 �h 6066 tlal 6.0640 0•06006 66,6 • s6.Cr.®d.O1wol- -enfo,v • 04sn0060 etn 66066 O. 0•0.66 0666 6666 fog: 0.16. (20006 MAN LOW-PEAK' Time -Delay Fuses Class L - 600 volt KRP -C 2001 -6000* 2 k 8 7000 MOM .0000 Ocal • Una a a o I o 8 I •iiiuIIlI1 ii.IluiIIuviii wordtt•<Ori�t•!•�t1WWW�r!• i• .z■ aum.wI. ut.utn� � ■III ■Blllu■■�II���I�I� �i� W11iu11u•Wfillnr rS. I1111IIIIII�mID!an %c wtuEM.O�NIM �E _.v .�11ry MEM\I ��tt11u1tII. /_.0.MAt1'411�31 ■■. f■.n60 /AmO■P!:A'>•■K MIinoiiun � i PMIIN �Ci. C�tlTtu�tUll /i1/RSGf �tlmtttl�ll. ■ ■KN ■KIII: %":AII ■�IIIIU ■ ■K ■UIIIII/:.i%U•IIIiIIIII•UU AIIIII••IIIIIIIIIJIII .00.0" �..10.■.�..■ ■a■.■■ aim . ••∎= �io■�..iiii�__vGii∎ ••iili��.. iliioa..rii =0 .a ...1•■1ifi AMMONNEIMMENIMEMEMINENIENIMINIMEN III■UIIII� ■iiuI ■iiIfl •i 3000A FUSE - EXISTING SCALE NONE 400. 3000. 1®61 12664 006. 001A 12.47 1500KVA XAM 733% Z KV 12.47 X62414150010/A (4) 750 kcml AL KV 7.33% Z (4) 750 kcml AL 1 20004 CURRENT FUSE SECTION PSE r 30004 CURRENT LIMIT FUSE SECTION - (6) SETS OF 400 KCMIL CU ABCN . 2 HOU�R PSE��ROVIDE FIRE RATING (TYP) •• _ 30006 CURRENT LIMIT FUSE SECTION LOW -PEAK* Time -Delay Fuses Ctxs L - 600 Volt EXISTING BUS DUCT EXTENDED TO PSE VAULT EXISTING BUS DUCT EXTENDED TO PSE VAULT 60006 BUS ONE -LINE DIAGRAM - EXISTING SCALE NONE KRP-C 2001.0000A t_. .0...a 1000_a0 note* -4 vordt l!*t N. Snl. OMw1.d Mots Olio E@I 0010A+N6 er.. me`- 000 vu AC RIO& em...0.� n■.c 9.306 i066 6 pa) .. P.. c.d.Fi6t iES6l2 470.0r060 5100000•1a. 104.. Ee WV/ O.616.667.O.00.06 0.60 6060 6.6 Ammon. 0.0.00 a61to•lat NOM Ono, trees. • Moo 016600 Ow b 6001066060 tivloui 090000tr MP COCO 001070 Pare e 6WO* ,70066 1610661 loom. 0 m i O a60 • 060.6006 Om et overa6 6.6 0666 • DbrWO 610 daccuoo 6000=. - 0660.1 WC Sedva109n >'.66101066 060 00000. bpc 01:1 woe 16 0.66 • HO 066 06061116 66616 ounoeai Dee 00666166010x'00609 Ed. uo treta0._ • 9sv6o 6 n Or 666616 b6.. maw 660o laima..e 0 nto 0061 �h 6066 tlal 6.0640 0•06006 66,6 • s6.Cr.®d.O1wol- -enfo,v • 04sn0060 etn 66066 O. 0•0.66 0666 6666 fog: 0.16. (20006 MAN LOW-PEAK' Time -Delay Fuses Class L - 600 volt KRP -C 2001 -6000* 2 k 8 7000 MOM .0000 Ocal • Una a a o I o 8 I •iiiuIIlI1 ii.IluiIIuviii wordtt•<Ori�t•!•�t1WWW�r!• i• .z■ aum.wI. ut.utn� � ■III ■Blllu■■�II���I�I� �i� W11iu11u•Wfillnr rS. I1111IIIIII�mID!an %c wtuEM.O�NIM �E _.v .�11ry MEM\I ��tt11u1tII. /_.0.MAt1'411�31 ■■. f■.n60 /AmO■P!:A'>•■K MIinoiiun � i PMIIN �Ci. C�tlTtu�tUll /i1/RSGf �tlmtttl�ll. ■ ■KN ■KIII: %":AII ■�IIIIU ■ ■K ■UIIIII/:.i%U•IIIiIIIII•UU AIIIII••IIIIIIIIIJIII .00.0" �..10.■.�..■ ■a■.■■ aim . ••∎= �io■�..iiii�__vGii∎ ••iili��.. iliioa..rii =0 .a ...1•■1ifi AMMONNEIMMENIMEMEMINENIENIMINIMEN III■UIIII� ■iiuI ■iiIfl •i 3000A FUSE - EXISTING SCALE NONE 400. 3000. 1®61 12664 006. 001A EXISTING BUS DUCT EXTENDED TO PSE VAULT EXISTING BUS DUCT EXTENDED TO PSE VAULT 60006 BUS (4000A MAN LOW -PEAK• Time -Delay Fuses Class L - 600 Volt ONE -LINE DIAGRAM - NEW SCALE: NONE KRP -C 601 -2000A Tarr.. 6641.6 1-PC;P 1066-006 - 4 1003070 6660101 60. 06 066 0661066 . 0010E60MO62 00to . 4 mo V66 AC 0 6v 60600 CC 101 �941 ▪ .w..e.■0• w lm.®t .o.r6 406•.011• 0.a1066 6CWam�04310riF 0361 4�/.fi pro 06-0 AF1,M .ear, w.•.mb. .tw,cs. ,062.e .+D vlm66 `u v0.666-a 66166 w 6▪ .6 os....640160106 • are-a.. • M.e 4d 4s b6 616. 06661p 060 00666 6 00.0600 goo traint nrci .l ..d e,e6�, • Tmch090 b. ads.fie 0000 .5 • C0M4•a1y636101h In..red1 m.= oast, ae.6.vp • Mers .11 a�im.ro..: 0000m rcL saskre 119-0 60 E0W bo6+yt u1Ds ceps a 60010 action rod ndlee(b doto • 201066 Woo 0 660 ,66 0 60 I0 �200o . Ikgo gerd.1 UW 001 6 r_ • 3n. w• l20 6:1 Or 0.10 Soowldr- e.6606.0Ofto0066066 66 ft 01 n7- 2.,a.-t'"�C.®.trnlrnt tl-ry 6 t... -w d • SYW W m Nan maw pw+6.1. (20006 MAN LOW -PEAK* Time -Delay Fuses Class L - 600 Volt GENERAL NOTES: 1. 6 -400 kcml PER SET OF CABLES. 6 x 4 - 24 x 2 TRANSFORMERS - 48 - 400 kooll TOTAL 2. NEC 392.10(Q - 24" CABLE TRAY = MAXIMUM ALLOWABLE Flt = 26 50114RE INCH. OUTSIDE DIAMETER OF 400 kanl THNN/1HWN = 0.918 INCH RADIUS = 0.459 INCHES. AREA = .6619 SQUARE INCHES A MAXIMUM OF 40 CONDUCTORS ON A 24" CABLE TRAY. (2) 24" CABLE TRAYS STACKED ARE REQUIRED. REFERENCE NOTES: REPLACE EXISTING 3000A FUSE WITH NEW 20004 FUSE FUSES SHALL BE ATTACHED DIRECTLY TO THE TRANSFORMER REVIEWED FOR DE COMPLI CE PPROV NO • 1 2012 of Tuk a B DING DIVI KRP -C 601 -2000* Qaraat- Unallation Curves 2 `i 8 888° 8 8888° R � RS68� $ � � ��8� 8 8 SOCOOD 300000 .0000 00300 .0000 • MMIMMMIIMMMMIN 111.111•11. M1011010100110011 IIIIIMINIMEZ00■11010•1111 10111101111101011001 NI...111...11111 =IN. ■ ■II ■.IIII�■i.I■iuI i v u tOt ■Etlt tlttttEMtlOMIllttt'IN/5! ■ ■II ■IIIf111�■ ■II ■IIII!�i�: uuIIIIII111 W H11■ IIrioake:i 118/11111uu1111PRIP-!; %: �- . ■�.....�w.�. -ter MI.o�...rrw�.r ..�►�.11 fir SIM MI.. BIEMIU t�� .. /it'd /AM/ m■umtENIMir_:ddle2mIWi.•Ls MONM NI / /NM.OPMMIN MILANit tm■Emnit>os MIEM:E .r--uLe ■ui ■1I■r %auu. ■uIIJItr I1 r!T III•II!:i %■I1111I11111dieVt. 1111P1111111111111111111 11111111t L M..•. =.ia..�a...■a.a ■i... 1•. M.e■oon 10o. =ocu ∎0•1•. ■.II....Iiu1.11...u..i 111•11. 5111•1•91 Ol.��.i. .I .. mums .aoa..o■.�010...a...I.. ten 401101...M...1I 01•11111•1111001.1110•1110100001M 30061 25001 1000k 100A VIEWED FOR PLIANCE WITH PA70 -NEC 2000A FUSE - NEW SCALE: NONE 8 8 8 8 8886 $ > CMS; 11_10-7113 OV 13 2012 of Tukwila UELbING DIVISION REGtivti) CITY OF TUKW!IA NOV 13 2012 PERMIT CENTER z z 0. PROJECT 812169 ISSUED EMU 12.47 1500KVA 733% Z KV 12.47 KV ' 1500KVA 7.33% Z �IAAIT 20004 CURRENT FUSE SECTION I] 20006 CURRENT MT FUSE 5LL ION (6) SETS OF 400 KCMML CU ABCN TAPS BY OTHER (TIP) - (6) SETS OF 400 KCMIL CU ABCN . 2 HOU�R PSE��ROVIDE FIRE RATING (TYP) EXISTING BUS DUCT EXTENDED TO PSE VAULT EXISTING BUS DUCT EXTENDED TO PSE VAULT 60006 BUS (4000A MAN LOW -PEAK• Time -Delay Fuses Class L - 600 Volt ONE -LINE DIAGRAM - NEW SCALE: NONE KRP -C 601 -2000A Tarr.. 6641.6 1-PC;P 1066-006 - 4 1003070 6660101 60. 06 066 0661066 . 0010E60MO62 00to . 4 mo V66 AC 0 6v 60600 CC 101 �941 ▪ .w..e.■0• w lm.®t .o.r6 406•.011• 0.a1066 6CWam�04310riF 0361 4�/.fi pro 06-0 AF1,M .ear, w.•.mb. .tw,cs. ,062.e .+D vlm66 `u v0.666-a 66166 w 6▪ .6 os....640160106 • are-a.. • M.e 4d 4s b6 616. 06661p 060 00666 6 00.0600 goo traint nrci .l ..d e,e6�, • Tmch090 b. ads.fie 0000 .5 • C0M4•a1y636101h In..red1 m.= oast, ae.6.vp • Mers .11 a�im.ro..: 0000m rcL saskre 119-0 60 E0W bo6+yt u1Ds ceps a 60010 action rod ndlee(b doto • 201066 Woo 0 660 ,66 0 60 I0 �200o . Ikgo gerd.1 UW 001 6 r_ • 3n. w• l20 6:1 Or 0.10 Soowldr- e.6606.0Ofto0066066 66 ft 01 n7- 2.,a.-t'"�C.®.trnlrnt tl-ry 6 t... -w d • SYW W m Nan maw pw+6.1. (20006 MAN LOW -PEAK* Time -Delay Fuses Class L - 600 Volt GENERAL NOTES: 1. 6 -400 kcml PER SET OF CABLES. 6 x 4 - 24 x 2 TRANSFORMERS - 48 - 400 kooll TOTAL 2. NEC 392.10(Q - 24" CABLE TRAY = MAXIMUM ALLOWABLE Flt = 26 50114RE INCH. OUTSIDE DIAMETER OF 400 kanl THNN/1HWN = 0.918 INCH RADIUS = 0.459 INCHES. AREA = .6619 SQUARE INCHES A MAXIMUM OF 40 CONDUCTORS ON A 24" CABLE TRAY. (2) 24" CABLE TRAYS STACKED ARE REQUIRED. REFERENCE NOTES: REPLACE EXISTING 3000A FUSE WITH NEW 20004 FUSE FUSES SHALL BE ATTACHED DIRECTLY TO THE TRANSFORMER REVIEWED FOR DE COMPLI CE PPROV NO • 1 2012 of Tuk a B DING DIVI KRP -C 601 -2000* Qaraat- Unallation Curves 2 `i 8 888° 8 8888° R � RS68� $ � � ��8� 8 8 SOCOOD 300000 .0000 00300 .0000 • MMIMMMIIMMMMIN 111.111•11. M1011010100110011 IIIIIMINIMEZ00■11010•1111 10111101111101011001 NI...111...11111 =IN. ■ ■II ■.IIII�■i.I■iuI i v u tOt ■Etlt tlttttEMtlOMIllttt'IN/5! ■ ■II ■IIIf111�■ ■II ■IIII!�i�: uuIIIIII111 W H11■ IIrioake:i 118/11111uu1111PRIP-!; %: �- . ■�.....�w.�. -ter MI.o�...rrw�.r ..�►�.11 fir SIM MI.. BIEMIU t�� .. /it'd /AM/ m■umtENIMir_:ddle2mIWi.•Ls MONM NI / /NM.OPMMIN MILANit tm■Emnit>os MIEM:E .r--uLe ■ui ■1I■r %auu. ■uIIJItr I1 r!T III•II!:i %■I1111I11111dieVt. 1111P1111111111111111111 11111111t L M..•. =.ia..�a...■a.a ■i... 1•. M.e■oon 10o. =ocu ∎0•1•. ■.II....Iiu1.11...u..i 111•11. 5111•1•91 Ol.��.i. .I .. mums .aoa..o■.�010...a...I.. ten 401101...M...1I 01•11111•1111001.1110•1110100001M 30061 25001 1000k 100A VIEWED FOR PLIANCE WITH PA70 -NEC 2000A FUSE - NEW SCALE: NONE 8 8 8 8 8886 $ > CMS; 11_10-7113 OV 13 2012 of Tukwila UELbING DIVISION REGtivti) CITY OF TUKW!IA NOV 13 2012 PERMIT CENTER z z 0. PROJECT 812169 ISSUED EMU *EMIT COORO COri41.1 PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: EL12 -1065 DATE: 11/13/12 PROJECT NAME: J C PENNEY SITE ADDRESS: 1249 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: J% C Building Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/15/12 Complete 1 Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route N Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/13/12 Approved ❑ Approved with Conditions xr Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Prter Friendly Page Electrical Contractor A business licensed by L &I to contract electrical work within the scope of its specialty. Electrical Contractors must maintain a surety bond or assignment of savings account. They also must have a designated Electrical Administrator or Master Electrician who is a member of the firm or a full -time supervisory employee. Business and Licensing Information Name Phone Address Suite /Apt. City State Zip County Business Type Parent Company E C COMPANY 5032243511 Po Box 10286 Portland OR 97296 Out Of State Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 601107330 Active ECCOM "148BA Electrical Contractor 1/1/1986 6/30/2014 General Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status ELECTC*542CQ ELECTRICAT CONSTRUCTION OF OR Electrical Contractor General Unused 2/18/1946 12/31/1982 Archived ELECTCC541CQELECTRICALCONSTCO OF OREGON Electrical Contractor General Unused 2/18/1946 12/31/1985 Archived Master Electrician INFORMATION License TRAPPSC976RZ Name TRAPP, STEVEN C Status Active Business Owner Information Name Role Effective Date Expiration Date ADAMS, GEORGE HARRY 01/01/1980 SCROGGY, JOEL J 01/01/1980 BUSINESS FILINGS INCORPORATED Agent 06/28/2010 GOLDSTONE - SCHULLER, LEAH Member 06/28/2012 TRAPP, STEVEN C Member 06/28/2012 SCHMITZ, STEVEN D Member 06/28/2012 BALL, ROBERT SPENCER Member 06/28/2010 JANIK, STEPHEN THOMAS Vice President 06/28/2010 BOCK, JAMES ARTHUR Vice President 06/28/2010 DESHLER, WILLIAM K 01/01/1980 06/28/2010 KELLY, RAYMOND THEODORE 01/01/1980 06/28/2010 PRENTICE -HALL CORP Agent 01/01/1980 06/28/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 8 ST PAUL FIRE & MARINE INS CO 4005M9914 04/06/2002 Until Cancelled $4,000.00 03/18/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 11/14/2012