Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M12-022 - BOEING #9-101 - WATERJET RELOCATION
BOEING #9 -101 9725 EAST MARGINAL wys M12-022 City oikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0003400018 Address: 9725 EAST MARGINAL WY S TUKW Project Name: BOEING #9 -101 - WATERJET RELOCATION Permit Number: M12 -022 Issue Date: 02/24/2012 Permit Expires On: 08/22/2012 Owner: Name: BOEING COMPANY THE Address: PROPERTY TAX DEPT , PO BOX 3707 M/C 20 -00 98124 Contact Person: Name: CONNIE HARDIN Address: 4600 S 134 PL , SEATTLE WA 98168 Email: CONNIEH @HOLADAYPARKS.COM Contractor: Name: HOLADAY PARKS, INC. Address: PO BOX 69208 , SEATTLE, WA 98188 Contractor License No: HOLADPI379NO Phone: 206 250 -4530 Phone: 206 248 -9700 Expiration Date: 09/03/2013 DESCRIPTION OF WORK: PIPING UTILITIES FOR RELOCATION OF WATERJET MACHINE IN FACTORY. NEW CHILLED WATER PIPING, COMPRESSED AIR, INSTALLATION OF WATER FILTERS, PUMP AND CONDENSATE DRAIN PIPING PER PLANS. (RENEWAL OF M11 -064) Value of Mechanical: $44,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $722.56 International Mechanical Code Edition: 2009 Date: 601-1. I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating const tion or t e performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back •f thi • a.::t: `• Signatu Print Name: 0,1\ rtr(i( Date: 3 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-022 Printed: 02 -24 -2012 • • PERMIT CONDITIONS Permit No. M12-022 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -022 Printed: 02 -24 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.ci.tukwila. We. us ,(L&. O( 11 OG q Aoki- MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print** King Co Assessor's Tax No.: 00034-10(-X) 1, Site Address: 9725 East Marginal Way S Tenant Name: Boeing 9-101 Advanced Developmental Composites Property Owners Name: The Boeing Company Mailing Address: p0 BOX 3707 Suite Number: Floor: New Tenant: 0 Yes ..No Seattle WA 98124 City L.cONTAcTlIkits 7 . .:;:s tr' ■■•. Name: LAAt Mailing Address: 4600 S. 134th Place State Zip Day Telephone: (206) D.,szy--Q s---so Seattle WA .98168 City State Zip E-Mail Address: e_JOVIfl t .e.-t 1 VLblacia.iApt-A-rk-.5,0-hwt Fax Number: (206) 248-8700 „.... , . , 4417E024:10Ckl:00.1SPII4CX0000.0101A. ,o1 Company Name: HOLADAY-PARKS, Inc. Mailing Address: 4600 S. 134th Place - Seattle, WA 98168 Contact Person: (\ tes*, E-Mail Address: &CAA ; 6.) h Contractor Registration Number: HOLADP 379NO City State Zip Day Telephone: (206) 2_ st, Fax Number: (206) 248-8700 Expiration Date: 09/30/2013 i7,Alt(airr.41:CTIOV.ageORD'st.A11,14.diltISMIIISf. „ . 7' :3 Company Name: Mailing Address: City Contact Person: Day Telephone: E-Mail Address: Fax Number: State Zip Company Name: Mailing Address: Contact Person: E-Mail Address: HAAPPlinandnffunns-APPlicsnons On Line \2010 APPliolinns\ 7-2010 • Medanninal Permit APPlicinoldne Revised: 7.2010 bh • City Day Telephone: Fax Number: ,State Zip Page 1 of 2 • • Valuation of project (contractor's bid price): $ 44000.00 Scope of work (please provide detailed information): Piping utilities for relocation of Waterjet machine in factory. new chilled water piping, compressed air, installation of water filters, pump and condensate drain piping per plans Use: Residential: New Commercial: New Fuel Type: Electric 0 Replacement Replacement Gas ❑ Other 3 Indicate type of mechanical work being installed and the quantity below: furnace <100k btu air handling unit >10,000 cfin furnace >100k btu • floor furnace evaporator cooler ventilation fan connected to single duct fire damper diffuser thermostat suspended/wall /floor mounted heater ventilation system wood/gas stove 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu • appliance vent hood and duct repair or addition to heat/refrig/cooling system air handling unit <10,000 cfm 1 Incinerator — domestic emergency generator . other mechanical equipment 3 50+ hp /1,750,000 btu incinerator — comm/ind Valve of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE O ED AG NT: Signature: �\ C • Print Name: '111 1 p Ls :eC , t ,,. Day Telephone: 4600 S. 134th Place Seattle Mailing Address: City Date: . 10)0/1 (206) as-D-44 Ss-o WA 98168 State Zip lDate Application Accepted: o2_I i o 1'1 Z� Date Application Expires: D$ (-iti 2 I Staff Initials: / `6 1 l� 1 HMApp onsWtnms•Applic,GOns On Line 12010 Applications17.2010 . Mechanical Prnnit Applinnioadoc Revised: 7 -2010 bb Page 2 oft • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 0003400018 Permit Number: M12 -022 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 02/10/2012 Applicant: BOEING #9 -101 - WATERJET RELOCATION Issue Date: Receipt No.: R12 -00803 Initials: LAW User ID: 1632 Payment Amount: $295.03 Payment Date: 02/24/2012 04:22 PM Balance: $0.00 Payee: HOLADAY PARKS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 06441G ACCOUNT ITEM LIST: Description 295.03 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 295.03 Total: $295.03 doc: Receiot -06 Printed: 02 -24 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. A/02-o ?2 CITY OF' TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p, (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project::. Type of Inspection: Address: -S_ ; 1 r/ A,� ✓N c� Called: Special Instructions: 1 . f Date Wanted:. G �!�m. z.--2_ / -1 ' L p.m. Requester: Phone No: r _ ' _S 2 %A�/ o �O �� Jl ZApproved per applicable codes. E Corrections required prior to approval. COMMENTS: — 1 ? Insife ctor;.' Al 1 n REINSPECTION FEE REQUIRED. Prkor to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite,100. Call to schedule reinspection. Date? PERMIT COORD COPS PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -022 DATE: 02/10/12 PROJECT NAME: BOEING #9 -101 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: W frii 1(1- Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 02/14/12 Not Applicable Comments: °,Permit =Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/13/12 Approved Approved with Conditions [U Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: PermitCenter Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28 -02 Contractors or Tradespeople Pter Friendly Page • Page 1 of 2 General /Specialty Contractor A business registered as a construction contractor with LIII to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HOLADAY PARKS INC UBI No. 578004089 Phone 2062489700 Status Active Address 4600 S 134Th Pi License No. HOLADP1379NO Suite /Apt. License Type Construction Contractor City Seattle Effective Date 1/21/1983 State WA Expiration Date 9/3/2013 Zip 98168 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HOLADI *00105 HOLADAY PARKS INC Electrical Contractor Hvac /Rfrg Ltd Energy Unused 9/25/2000 4/21/2013 Active HOLADPF376N0 HOLADAY PARKS FABRCTRS INC Construction Contractor General Unused 8/20/1963 1/1/1983 Archived Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD T JR Chief Executive Officer 01/21/1983 VAN DER VEEN, JULIE ELIZABETH Member 08/26/2011 CONNELL, DANIEL AARON Member 08/26/2011 GIRI, BUIT Member 08/26/2011 KIEL, RINALD HOWARD Member 08/26/2011 WHITMYRE, CHRISTIAN Member 08/26/2011 BECK, DAVID CLARENCE Vice President 01/21/1983 OCONNOR, BONNY K Vice President 01/21/1983 NAILON, JUNE ANNETTE Vice President 01/21/1983 VAN DER VEEN, ERIC M Vice President 11/04/2010 PIZZEY, GRACE KATHERINE Vice President 08/26/2011 NELSON, MICHAEL Secretary 01/01/1980 11/04/2010 PARKS, DAVID L Treasurer 01/01/1980 11/04/2010 TALBOT, PAUL Treasurer 01/01/1980 11/04/2010 Bond Information https: // fortress .wa.gov /lni/bbip /Print.aspx 02/24/2012 v CI\ T' vAP PROJECT SITE FROM DOWNTOWN SEATTLE 900 rn 3' EXIT 158 ■ S BOEING ACCESS RD 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE — TACOMA AIRPORT D Tv -LOPV -NTAL CE\ T -R FROM KENT & AUBURN NO SCALE EXIT 157 900 BOEING DEFENSE & SPACE GROUP BUILDING 9 -101 RELOCATE WATERJET 9725 B.� -AST iKW AR LD T v =A v AP \C ADDR ARC \AL LA, WAS BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 981 WA" SO „T� GTO\ PROJECT SITE 9 -78 9-52 9 -35 0 FILE COPY Permit No. X2 2 Plan review approval is subject to errors and ice. Approval of construction documents does not wutho Ae the violation of any adopted code or ordinance. Ref; 33ot of approv conditions is mows .;g d: BY Dom -1 �-- City Of Tukwila BUILDING DIVISION G - RAL \ OT CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VEREY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAP- I S. 4. RLIURN THIS SAME SET TO JOHN MURDOCH AT BUILDING 9 -51.2 COLUMN L /1, AI- I ER COMPLETION OF THIS CONSTRUCTION. CHECK. BOX 13 -01 PROJ -CT C -C KE ST • THESE DRAWINGS CONFORM TO THE 2009 I.B.C., I.F.C., I.P.C., I.M.C., U.P.C. AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES AND COMPLIANCE WITH CI—Y OF TUKWILA ZONING. • ROOMS _,BELED PER OCCUPANCY PER I.B.C. ❑ BUILDING FLOOR NUMBER ON PRINT FOR AREA OF CONSTRUCTION. UMBER OF PRINTS REQUIRED FOR PERNIT PACKAGE: ❑ 1. GENERAL PERNIT (SHELL & CORE) ❑ 4 SETS OF STRUCTUAL REP_ACEMENT DRAWINGS ❑ 2. TENANT IMPROVEN ENT (NON— STRUCTURAL): ❑ 3. TENANT IMPROVEMENT (REVISION), 2 SETS. ❑ 4. MECHANICAL, 4 COMPLETE SETS. • BRIEF PROJECT N SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical t. Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION 9 -101 B� _D ARRATIVE: RELOCATE THE WATERJET AND ASSOCIATED UTILITIES. CORE DRILL ON THE WALL FOR WATERJET AND A.H.U. ACCESS LADDER INSTAILLATION. RELOCATE TWO (2) 14-FT WIDE PALLET RACKS. DRAWING \ D -X DRAWING NUMBER SHEET REV DATE TITLE 9- 101 —Al Al A 08.09.06 TITLE SHEET 9- 101 -1N61 1M61 D 03.17.11 HVAC PIPING — PARTIAL PLAN 9- 101 -1M62 1M62 B 03.17.11 HVAC PIPING — PARTIAL PLAN 9- 101 -1M112 1M112 N 03.17.11 FIRST FLOOR PLUMBING PLAN 9- 101- 1M112X 1M112X X 03.17.11 FIRST FLOOR PLUMBING PLAN 9- 101 -1M311 1M311 D 03.17.11 WATER JET PIPING DIAGRAM 9- 101 —N593 M593 C 03.17.11 SECTIONS AND DETAILS WATERJET 9- 101— UGM112 UGM112 A 03.17.11 PLUMBING UNDERGROUND PLAN 9- 101 —S593 S593 — 03.18.11 PARTIAL PLAN AND DETAIL 9- 101 —S594 S594 — 03.18.11 AHU PLATFORM ACCESS LADDER 9- 101 —S595 S595 - 03.18.11 PALLET RACK SCHEDULE AND DETAILS 9-101-1E116 1E116 -, 0'.16 11 480Y/277 VOLT POWER 9 -101 -1 E112R 1E112R — 03.16.11 277/48V POWER PLAN 277/408V POWER PLAN 9-101-1E112 1E112 - 03.16.11 9-101-1E62 1E92 ._`: — 03.16.11 03.1611 208Y/120V POWER PLAN LIGHTING 9- 101 -1E12 1E12 — . _ • R CODE COMPLIANCE AppR 3 2012 i�ifi .. LAND USE CODE BUILDING CODES OCCUPANCY GROUP CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT BUILDING GROSS TUNNEL FIRST FLOOR N EZZANINE AFFECTED AREA BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE COD S .,VMARY TUKWILA 2009 I.B.C., I.F.C., I.P.C., I.M.C., U.P.C. AND THE WAC 51 -20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. GROUP B AND GROUP F, DIVISION 1 (OFFICE AND FACTORY) TYPE H, NON— COMBUSTIBLE SEPARATION 60 FEET (MINIMUM ALL SIDES) 713,829 1,116,306 50,910 713,829 55,689 295,878 111 F I. MAXIMUM 2 OVERALL (NO CHANCES) BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 3 \G LOCAT 0\ NO SCALE REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOT: Revisions will require a new plan submittal and may include additional plan review fees. cmrLSRUn FEB 10 2012 PERMIT CENTER 12 -022 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A INSTALL PAINT EQUIPMENT 11305358 M.WONG RWS 03.18.11 B RELOCATE WATERJET 8291 -28 S. CHO RWS 03.22.11 Q� BOE /NG ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN W. MOOR CHECKED DATE 09— AUG -06 SUBTITLE TITLE SHEET CURRENT REVISION 11305358 SYMBOL A DATE 03.18.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL vASTER BUILDING 9 -101 SHEET Al JOB NO. 566282 -01 COMP NO. DWG NO. D.C. 9- 101 —Al 9- 101 —A1a P 1" PUMPED CONDENSATE FROM 9 -103 1" PIPING TO PENETRATE WALL TO 9 -103 BUILDING THROUGH CLOSED OFF WINDOWS. CONTINUED ON 9- 103 -1M60 P COND HWS '3-111/2" HWS &R TO 9 -103 AHU 2 1 2" PLUG HPS TO 9 -103 BUILDING. HPS HWR HPS HPC HWR HPS C2 H PS 4" 150# CI 3" HPS ISOLATED FROM SYSTEM AND ABANDONED IN PLACE •• Iv 1M M594 b 1i" HOS &R ZONE -2 CHROMOLUX NEI �I�iifYr 1 " HOS: . \. 3/4" HPC FROM DRIP TRAP AT DRIP LEG N O P.O.C. NUN MI MI 1" SCH -80 BLACK STEEL PIPE W/ 2" THICK FIBER GLASS INSULATION O V) O 0 S N 0 13" HOS &R ZONE -2 1i" HOS &R ZONE-1 .0 T Hais S ,, 1 I COND CHWR 11 v I ic] tt _ 91 1 1/2" COND 24 "X24" STM __ 1 1/2" MN • 2" COPPER T BING W/ 1" THICK FIBE GLASS INSULATION E CC1 a9 HPS COND CHWS CHWR 1" 3/4 0 O U CL 3" 150# 4" P COND SYM REVISION BY HWS 4" a9 HPS CC1 2 1/2" HWR 2" 150# -2 1/2" 24 "X24" HWR 4 CC2 1 1/2" as HWS —CONS 11 1M61 4528 —M3 CHWS 3" CHW' —+ 0 O U 1M61 4528—M3 2" P COND SWM R 3" 1 HWR 1 1/4" 1M61 4527M3 FIRST FLOOR PLA\ SCALE: 1/ 1' -0" LEGE \D HPC - HPS - STM - HWS - HWR - CHWR - - CHWS COND P COND- GE \ERAL CONDENSATE STEAM (HIGH PRESSURE) STEAM SUPPLY (HIGH PRESSURE 125, 250 PSIG) STEAM SUPPLY HEATING WATER SUPPLY HEATING WATER RETURN CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSATE PUMPED CONDENSATE TES CC\STRUCTO \OTES RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 206- 947 -4897, M/S 46 -87 PURCHASE & INSTALL 1Y" CHILLED WATER SUPPLY & RETURN FROM THE COL. F/2.5 TO THE COOLING WATER SYSTEM AT COL. K /1. USE TYPE —L COPPER TUBING WITH 1" THICK FIBERGLASS INSULATION. THE MAXIMUM PIPE HANGER SPACING SHALL BE 10 FEET. 2. INSTALL PIPE LABEL ON THE INSULATION. \ REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 3 2012 City of Tukwila BUILDING DIVISION N1 12 O�z REFERENCE DRAWI\ GS R�itil�t3/ ,,��� CITY O nit LA FEB 10 2012 PERMIT CENTER T 7 V f T T T 1M60 /1y 1M62 1M63 1M64 1M65 1M66 1M67 1M68 1M69 1M70 1M71 1M72 1M73 1M74 1M75 1M76 1M77 1M78 1M79 1M80 1M81 1M82 1M83 1M84 1M85 1M86 1M87 1M88 —� 1M89 1M90 1M90 1M92 1M93 1M94 • 1M95 1M96 APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN KB /CH A LGE- AUBURN LAB ON -LOADS J #130198 -00 M.WONG RWS 09.30.03 B INSTALL CLEANROOM 140795 -01 RWS RWS 06.28.05 C REMOVE CHROMOLOX HX SYSTEM D EPME DESIGN WATERJET RELOCATION 8310290 11622250 RWS M.WONG RWS RWS 01.21.09 03.17.11 0))1.±taterE2FAKa ° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED — DRAWN DATE APPROVED BY DEPT. DATE CHECKED SUBTITLE HVAC PIPING - PARTIAL PLAN ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDI \1G 9 -101.1 COL. E —J/1 -6 D.C. CURRENT REVISION 11622250 SHEET SYMBOL DATE 03.17.11 1 M o 1 JOB NO. COMP NO. DWG NO. 9- 101 -1M61 di 3 /4 "HPC 1M62 4528 -M2 1Y2 "CHWS & R DN. TO WATERJ SEE M593 1M62 4528 -M2 PACE A -18 5800 CFM --Li it 1 1/4" I 1 1 /2 "HWS &R HWR HWS HPS -3" PORTABLE EYEWASH STATION HWR COND RECEIVER VEN Q O U BA BEN DRAFT BACKDRAFT BENCH Q U 0 2 1 /2" 3 "CHWS &R —� 4" CHWS &R 4" CHWS &R 8 "CHWS &R THRU CEILING V 1" CHWS HWS -�-- -- P COND CHWR - HWR COND ol- a MN 1NAA 0 COND HWS HPS KING DOOR HTR MODEL 510 -14 460V, 30 r EXIT G) 1" SOL VIV STRAINER 1 1 /2 "HWk 1 1 /2 "H WIR HWo TRANE SIZE 12 5HP 6360 CFM 1 1/2" CH-WS CHWR 1 1/4" COND 2 1/2" 150# HPS 7.-1 1/4" /AHU\ �22� �---- - - - - -J HWR 2" VENT 2 1/2" H WS HWR P COND 2 1/ 11 0_ 1/ F J EXIT x x <AHU> COND CHWS 1 M62244527 —M3 HUMIDIFIER 3" 1 1/4" —BOND 1 F- Cn FUNNEL DRAIN CMCS TEM ® CEILING SENSOR dam- HWR -4 2" 3" HWR HWS STM P COND 11 2 1 1/4" V� V 1 2" V M6214528 —M3 1M6214528 —M3 I (1) 0_ 2 �-2 1/2. 150# » x HWS REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 3 2012 City of Tukwila BUILDING DIVISION x x x HWS HWR U 2i _ 0 x x x Q V d d B HWS r. x x x x SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE REDRAWN KB CH /EJC 11.11.97 PUR /INSTALL MODULAR CLEAN ROOM J #546610 -01 C. HARRAH RWS 10.01.04 B EPME DESIGN WATERJET RELOCATION 11622250 M.WONG RWS 03.17.11 1 2 "COPPER FROM FREEZER DRAIN PUMP x x x x 0 V FIRST FLOOR PLA\ LEG E HPC HPS STM HWS HWR - CHWR- - CHWS COND P COND- GE\ ERAL CONDENSATE STEAM (HIGH PRESSURE) STEAM SUPPLY (HIGH PRESSURE 125, 250 PSIG) STEAM SUPPLY HEATING WATER SUPPLY HEATING WATER RETURN CHILLED WATER RETURN CHILLED WATER SUPPLY CONDENSATE PUMPED CONDENSATE \OTES CC\STRUCTI \ \OTES RETURN REDLINED PRINT BACK TO ENGINEERING WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 206 - 947 -4897, M/S 46 -87 PURCHASE & INSTALL 1)/2" CHILLED WATER SUPPLY & RETURN FROM THE COL. F/2.5 TO THE COOLING WATER SYSTEM AT COL. K /1. USE TYPE -L COPPER TUBING WITH 1" THICK FIBERGLASS INSULATION. THE MAXIMUM PIPE HANGER SPACING SHALL BE 10 FEET. 2. INSTALL PIPE LABEL ON THE INSULATION. M12O22 SCALE: 1/8"= 1 -0" /2" COND TO SERVICE SINK, SEE 4535 M2 6 9 -10 GrIA FEB 10 2012 PERMIT CENTER T / V T T T T 1M60 1M61 1M62 1M63 1M64 1M65 1M66 1M67 1M68 1M69 1M70 1M71 1M72 1M73 1M74 1M75 1M76 1M77 I 1M78 1M79 1M80 1M81 1M82 1M83 1M84 1M85 1M86 1M87 1M88 1M89 1M90 1M91 1M92 1M93 r 1 1 V 1M�94 I= Y PI AM 1M95 1M96 INit III III 11 23 QiBOE /NG° - ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED 'A" K.BUN CHECKED C.HARRAH SUBTITLE PIPING FIRST FLOOR PLAN CURRENT REVISION 11622250 SYMBOL DATE 03.17.11 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 9-101.1 COL. 6- 11 /J -N D.0 SHEET 1M67 JOB NO. 546610 -01 COMP NO. DWG NO. 9- 101 -1M62 H i" AIR TO FILTER (P H i" AIR HOPPER #2 1H4" AIR HOPPER #1 1" CW (COPPER) RPBP WATTS 009-1" SN#50330 TRAP PRIMER 4)1 1,,cat. BFP FLOW METER -PRESSURE REGULATOR 85K002363 •411 Cl 3/4" HOSE BIBB I "-1" PW Fi (COPPER) Y2"COPPER W/ 2"0 FLOOR SINK PIPE TAPE WRAP 12X12X8 WADE UNDERGROUND) 9142-NH-6-27 ..(11 cF bJ CD ci *" DRAINS TO FD FINISH FLOOR 4"x4" CONCRETE CURB AROUND FLOOR DRAIN CZ 1..11 0 V) uJ uJ (1) JET EDGE INTENSIFIER 50 HP y2" FILTERED WATER (PVC SCH-80) IH POST FILTER Y- 2"NPT, FILTERED WATER IN Y2"NPT, DRAIN Y2"NPT, COOLANT WATER OUT h"NPT, COOLANT WATER IN 3/6" HIGH PRESSURE COUPLING WATER JET (JET DC SCALE NONE 1) - Y2"ID HOSE, FILTERED WATER IN 3/4" COPPER DWV h'ID HOSE, COOLANT WATER OUT J'"ID HOSE, COOLANT WATER IN /8"0.D. x Y8"I.D. 316 STAINLESS STEEL TUBING (NOTE: ALL HOSES SHALL BE PARKER 801-8) PIP1\ _3/4" COOLING WATER SUPPLY & RETURN DIAGRAM SEE DWG. 1M62 FOR THE CHILLED WATER PIPING CONTINUATION (f) = = pp 1M534 1M311 —65'F SET POINT 17 Z // Le- -el / — 1- / Q i rs1i I* ID a--ii" G & L NPE 1 x1.25-6, 316SS, 5.75" IMPELLER, CAT. #1STAF5B4, 1.5 HP, 3500 RPM, 30, 20 GPM © 120' HD (INTERLOCKED W/ INTENSIFIER) EXTROL 15, W/ AIR PURGER 445, AUTO VENT 700C TSET THE PUMP DISCHARGE PRESSURE CI) 60# i—S-CB B&G CIRCUIT SETTER, SET © 8 GPM Q -91 i'0 Q tTiLe- ).0) SOLENOID VALVE, N.C. c/c 3" COPPER at 00 )i" COOLING WATER FILL LINE — 1 49- 1)2" COPPER, COOLING WATER -NI LOOP =-1—/ LEGE\D 3/4" SELF—CONTAINED TEMPERATURE REGULATOR, SINGLE SEAT STAINLESS TRIM, COOLING, COPPER BULB & CAPILLARY, 8' CAPILLARY, FIXED UNION BULB, INDICATING, 45T TO 105'F RANGE, POWERS #11 REGULATOR 595-075—ST—CC08D102. SET THE TEMPERATURE TO 65T. ALFA LAVAL PLATE HEAT EXCHANGER, M3—VG, 149,600 BTUH, HOT SIDE: 20 GPM, 80T EWT, 65T LWT, 4•99# DROP, COLD SIDE: 16.97 GPM, 45T EWT, 62.5'F LWT, 3.71# DROP, AISI 316 PLATE, 23 PLATES, NBRP CLIP—ON GASKET MATERIAL, DESIGN PRESSURE AND TEMPERATURE OF 100 PSI @ 150T. 13/4" SOLENOID VALVE, NORMALLY CLOSE, 120V, BRASS, ASCO 8210G55. INTERLOCK WITH THE INTENSIFIER TO "OPEN" ONLY WHEN THE INTENSIFIER IS "ON". CONSTR CTO\ OTES SEE DRAWING M593 FOR THE CONSTRUCTION NOTES. 1 WILKERSON M32-08- FOO COMPRESSED AIR MA\ SCALE: NONE 1" COPPER IFOE, (2 1 M 534 1)/1 311 •■••■•••.s.. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 3 2012 City of Tukwila BUILDING DIVISION 1L4-02-2- en,tomitA FEB 1 0 2012 PERMIT CENTER SYM A B D REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CHANGE OUT WATERJET-JET EDGE RELOCATE WATER JET REPLACE WATER JET EPME DESIGN WATERJET RELOCATION 526545-06 130185-02 585560-01 11622250 M.WONG M.WONG M.WONG M.WONG RWS RWS RWS RWS 02.12.03 05.15.03 10.27.08 03.17.11 ZLArmerAriswe DRAWN ACCEPTABILITY M.WONG THIS DESIGN AND/OR CHECKED SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE ENGINEER M.WONG DATE SUBTITLE 02.06.03 WATER JET PIPING DIAGRAM CURRENT REVISION 1 1 622250 SYMBOL DATE 03.17.11 02.06.03 CHECKED APPROVED R.SQUIRES 05.15.03 APPROVED TITLE MECHANICAL MASTER BUILDING 9-101.1 DEV. CENTER, WA SHEET 1M311 JOB NO. 526545-00 COMP NO. DWG NO. 9 —101-1M311 WONGK: 03/18/11 12:06 c NEW WAT IPJET LOCATIO ABRASIV OPPER WOOD PALLET ABRASIVE HOPPERS STORAGE 42X48 EXPANSION TANK TEMPERATURE SENSING BULB 20GPM CO 120', G &L NPE, 1.5HP INTERLOCK W/ INTENSIFIER SEE DWG. 1M311 FOR PIPING DIAGRAM ABRASIV HOPPER 442‘ % "CWS &R PPP- 1Yz" CHWS & R UP SEE DWGS. 1M61 & 1M62 1> 2 > p 3/4"CWS&R POST FILTER (RELOCATE) n Y COPPER TYPE —L Y "DUPLEX (EXIST) P.O.C. Z- X 1 ALVE ON RISER 1" A (COPPER) . "ID, S.S. RESS. LINE PRIMER c�u ■!■�I P.O.C. WATER JET PIPI \G PLA\ 1 SCALE 1 /4 " =1' -0" 1M311, 1M112IM593 -1 m 4 SEE 2 III �E■= Y "DUPLEX PARKER IPBS - 501 -8MP 4 SEE K9101 MK) "DUPLEX J'= (EXIST) r � 1" UP 1" PW (COPPER) 19 21WILKERSON FILTER M32 -08 -000 x 1 "A UP SEE DWG. 1M112 Abresiv oppers 2" SAN. DRAIN MANIFOLD, PVC SCH -80 1" PW, COPPER POST FILTER (PROVIDED BY SIEMENS) FLOW METER ON THE VERTICAL SECTION 1" PW, PVC SCH -80 ■ _—gumI 11 • • IIII SIEMENS SOFTENER, y - KFZSS012FXZFAX ,iii 0 IN INTENSIFIER PUMP 50 HP DL CW PW EXST\C WATERJET LOCATIO\ 0 iii /1111111,�7 .�,�_._ �C �� —iii .�ill // 4 PW HO.E BIBB Bed F A -72-" FILTERED WATER PVC SCH -80 BRINE TANK 14.5"0, MU ' MEDIA FILTER • "U, e GI-.1-1 AT 5' -6 •: —FO0 S1 EE P DW 16 FOR CON'T 480 AIR FILTE WICKER M32— �e•' ent .nk 1 "DRAIN FITTING 9 , SEE DWG. 116 FOR CON'T — TEMPERATURE SENSING BULB 20GPM ® 120', G &L NPE, 1.5HP 1 ECM PI • VALVE F.F. EXPANSION -TANK OSE 3/4" A 5' -0" A.F.F. 1 "A P.O.C. n 0 m 0 x rn 0 3/4"CWS&R 1" CW DWG. UP SEE 1M66 3/4"CWS&R - COOLANT SUMP "2" SAN. DRAIN MANIFOLD, PVC SCH -80 1—" CHWS & R UP SEE DWG. 1M66 REVIEWED FOR CODE COMPLIANCE APPROVED FEB 2 3 2012 City of Tukwila BUILDING DIVISION 19 PURCHASE & INSTALL 1Y" CHILLED WATER SUPPLY AND RETURN FROM COL. F/2.5 TO THE COOLING SYSTEM AT COL. K /1. SEE DWG. 1M61 & 1M62 FOR THE PIPING PLAN. 2> EXTEND THE COOLANT WATER SUPPLY & RETURN FROM THE HEAT EXCHANGER TO THE INTENSIFIER USING TYPE —L COPPER TUBING. INSULATE THE PIPING USING Y" THICK ARMAFLEX INSULATION. RE— INSTALL A FLEXIBLE HOSE FROM THE SEDIMENT TANK DRAIN VALVE TO THE NEW FLOOR DRAIN. 22. ALL PIPING FABRICATION AND INSTALLATION SHALL CONFORM TO THE UNIFORM PLUMBING CODE. 23. PURCHASE & INSTALL PIPING LABELS ON ALL NEW PIPING PER BOEING STANDARD. 24. PERFORM THE OPERATIONAL TESTS ON ALL THE SYSTEM INSTALLED AND VERIFY THAT THE SYSTEM ARE WORKING PROPERLY. 1> REMOVE THE DRAIN LINE ON THE WALL. REMOVE THE COOLING WATER PIPING ON THE WALL. REMOVE THE WATER PIPING ON THE WALL. REPAIR ALL PIPE PENETRATIONS ON THE WALL. REMOVE ONLY THE 1" COMPRESSED AIR LINE TO THE WATERJET BUT LEAVE THE REST OF THE COMPRESSED AIR PIPING IN PLACE. (DON'T REMOVE) LEGE \D 3/4" SELF— CONTAINED TEMPERATURE REGULATOR, SINGLE SEAT STAINLESS TRIM, COOLING, COPPER BULB & CAPILLARY, 8' CAPILLARY, FIXED UNION BULB, INDICATING, 45T TO 105T RANGE, POWERS #11 REGULATOR 595- 075— ST— CCO8D102 ALFA LAVAL PLATE HEAT EXCHANGER, M3 -VG, 149,600 BTUH, HOT SIDE: 20 GPM, 80T EWT, 65T LWT, 4.99# DROP, COLD SIDE: 16.97 GPM, 45T EWT, 62.5T LWT, 3.71# DROP, AISI 316 PLATE, 23 PLATES, NBRP CLIP —ON GASKET MATERIAL, DESIGN PRESSURE AND TEMPERATURE OF 100 PSI © 150'F. CG \STRUCTIO\ \OTtS RETURN REDLINED PRINT BACK TO ENGINEER WITH ANY CHANGES FROM THE DESIGN. MOON WONG, 655 -8428, M/S 46 -87 SCOPE: THIS JOB IS TO RELOCATE THE WATER JET, THE INTENSIFIER, WATER SOFTENER, COOLING WATER SYSTEM AND PROVIDE THE UTILITIES TO SUPPORT THE ABOVE ITEMS. THE CONTRACTOR SHALL OBTAIN ANY PERMITS NECESSARY. RELOCATE THE WATERJET AND ASSOCIATED EQUIPMENTS. RELOCATE THE ABRASIVE HOPPERS, FILTER AND SEDIMENT TANK AT THE LOCATION SHOWN. RE— CONNECT THE COMPRESSED AIR AND DRAIN. RELOCATE THE JETEDGE INTENSIFIER. REPLACE 1 "0 COMPRESSED AIR LINE FROM THE 90' ELBOW ON THE CEILING DOWN STREAM OF THE ISOLATION VALVE, DOWN THE COLUMN K/2 AND UP TO THE LOCATION SHOWN ON THE FENCE. SEE DWG. 1 M 112X FOR THE REMOVAL AND DWG. 1M112 FOR THE COMPRESSED AIR SUPPLY CONNECTION. PURCHASE & INSTALL 1"q5 COMPRESSED AIR LINE TO THE WATERJET. 6 PURCHASE & INSTALL A NEW COMPRESSED AIR FILTER ON THE COL. K /2. RE— CONNECT THE EXISTING TWO DUPLEX AIR DROPS ON THE FENCE. PURCHASE & INSTALL A NEW Y" DUPLEX AIR DROP ON THE FENCE PER SKETCH K9101 MJ. (WEST SIDE OF THE FENCE) RE— CONNECT THE MEDIA FILTER, WATER SOFTENER & BRINE TANK USING THE FLEXIBLE HOSES SIMILAR TO EXISTING. RUN THE DRAINS FROM THE MEDIA FILTER & WATER SOFTENER TO THE FLOOR DRAIN. 1> PURCHASE & INSTALL A NEW 1 "0 CITY WATER FROM THE 2"0 ISOLATION VALVE ON THE CEILING DOWN TO THE COL. K /2. USE TYPE —L COPPER TUBING. INSULATE THE CITY WATER WITH %4" ARMAFLEX PIPE INSULATION UP TO THE MEDIA FILTER. RELOCATE THE BACK FLOW PREVENTER W/ REGULATOR TO NEW LOCATION AND CONNECT 1" CITY WATER SUPPLY TO IT. RECERTIFY THE BACK FLOW PREVENTER. PURCHASE & INSTALL A TRAP PRIMMER ON THE COL. K/2 AND RUN Y" UNDERGROUND LINE W/ PIPE TAPE WRAP TO THE FLOOR DRAIN. SEE DWG. UGM112 FOR THE NEW FLOOR DRAIN INSTALLATION. PURCHASE & INSTALL A PROCESS WATER LINE FROM THE BACK FLOW PREVENTER TO THE MEDIA FILTER. USE TYPE —L COPPER TUBING. 14 INSTALL A %4" HOSE BIBB FOR THE WATERJET. PRUCHASE & INSTALL THE WATER LINE FROM THE SOFTENER TO THE INTERSIFIER. 16 RE— INSTALL THE BLUE FILTER DOWN STREAM OF THE SOFTENER. PURCHASE & INSTALL THE HIGH PRESSURE WATER LINE RATED FOR 60,000 PSI (3 / "0.D.x "I.D. 316 STAINLESS STEEL TUBING) FROM THE INTENSIFIER TO THE WATERJET WITH MINIMUM TURNS. BEND THE TUBING FOR THE 90' TURNS WHERE POSSIBLE WITH MINIMUM BENDING RADIUS OF 1.75 INCHES. INSTALL THE FLEXIBLE STEEL CONDUIT— SLEEVE OVER THE TUBING FOR PROTECTION IN CASE OF A LINE BREAK. CLAMP THE UHP TUBING TO THE UNISTRUT OR OVERHEAD BRACING FOR STABILITY EVERY 5 FEET. (HAGEN INTERNATIONAL & ASSOCIATES, INC. 1510 BOUNDARY BLVD, #100, AUBURN, WA 98001 253 - 872 -4893 SHALL BE THE SUB — CONTRACTOR FOR THE HIGH PRESSURE PIPING.) 18 RE— LOCATE THE COOLING WATER SYSTEM TO THE NEW LOCATION SHOWN. THE COOLING WATER SYSTEM INCLUDES A PUMP, A HEAT EXCHANGER, AN EXPANSION TANK, A CONTROL VALVE & A SOLENOID VALVE. REPAIR THE DAMAGED PIPE INSULATION. (NOTE: THE PUMP & THE SOLENOID VALVE ARE INTERLOCKED WITH THE WATERJET SO THAT THEY ARE "ON /OPEN" WHEN THE WATERJET IS "ON ".) 1 SYM A B C REVISION BY APPROVED DATE SYM R EVISION BY APPROVED DATE RELOCATE WATER JET 4130185 -02 M.WONG RWS 05.15.03 REPLACE WATER JET J #585560 -01 M.WONG RWS 10.27.08 EPME DESIGN WATERJET RELOCATION 11622250 M.WONG RWS 03.17.11 Q�BOE /NG° ACCEPTABILITY THIS DESIGN AND /OR SPECIFICATION IS APPROVED DRAWN M.WONG DATE 05.05.03 CHECKED SUBTITLE SECTIONS AND DETAILS WATER JET (JET EDGE) I CURRENT REVISION 11622250 SYMBOL DATE 03.17.11 APPROVED BY DEPT. DATE ENGINEER M.WONG 05.05.03 CHECKED APPROVED R.SQU IRES 05.15.03 APPROVED TITLE MECHANICAL MASTER CITY�F"TtfK BUILDING 9 -101 02 COL x —x /x —x SHEET M593 JOB NO. DC I DWG N0. COMP NO. 130185 -02 9- 101 —M593