Loading...
HomeMy WebLinkAboutPermit M12-120 - HOMEWOOD SUITESHOMEWOOD SUn1ES 6955 FORT DENT WY M12 -120 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 2954900460 6955 FORT DENT WY TUKW Project Name: HOMEWOOD SUITES Permit Number: M12 -120 Issue Date: 09/11/2012 Permit Expires On: 03/10/2013 Owner: Name: Address: Contact Person: Name: Address: Email: APPLE EIGHT HOSPITALITY OWN 814 E MAIN ST , RICHMOND VA 23219 JESSE LEMBECKER 825 S STACY ST , SEATTLE WA 9 +8134 JESSEL@ GREEN W OODHEATING. C OM Contractor: Name: GREENWOOD HEATING & A/C Address: 2850 YANCY ST PMB 203 , SEATTLE WA 98126 Contractor License No: GREENHA922U7 Phone: 206 - 255 -3248 Phone: 206 - 365 -3313 Expiration Date: 02/03/2013 DESCRIPTION OF WORK: REPLACE 42 HEAT PUMPS LIKE FOR LIKE CHANGE OUTS. UNITS 100, 102, 107, 109, 120, 121, 130, 132, 137, 139, 160, 162, 167, 169, 170, 171, 172, 173, 200, 202, 204, 205, 207, 208, 220, 222, 224, 225, 226, 227, 300, 301, 302, 303, 320, 321, 322, 323, 400, 402, 420, & 422 Value of Mechanical: $25,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $489.81 International Mechanical Code Edition: 2009 QJ Date: b'-' t 1- GZ I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority-to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorize .1.6-'sign and obtain this mechanical permit and agree to the conditions on the back of this permit, Signature: Print Name: 7_11.e4 1„ f 4 r-- Date: -// -Loa This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12-120 Printed: 09 -11 -2012 • • PERMIT CONDITIONS Permit No. M12-120 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -120 Printed: 09 -11 -2012 CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** Site Address: -j 55 For+ De 1`T Tenant Name: 14conew St-6 King Co Assessor's Tax No.: Z:15 "['l o - o "l to D Suite Number: Floor: New Tenant: ❑ Yes Valuation of project (contractor's bid price): $ W % aCt n./ V2 yP�7//ovi,f/fp /2 f C1C Describe the scope of work in detail: Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric N. Gas Other: 1 H:\Applications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 '` Company Name: ^ ( eenu ooc? \\ a:Cuttj b A[C- Address:$,5 S . SiACtit S+ City: S `M'tQ -state: toy Zip:q 13 Phone: alu ` t i4 M 1 %Fax. 2-0(o (-1(02. 402-1‘47 Contr Reg NC*0..E EN. AAcztri. p Date: 2.3" 13 Tukwila Business License No.: ISLAS- D993323 Valuation of project (contractor's bid price): $ W % aCt n./ V2 yP�7//ovi,f/fp /2 f C1C Describe the scope of work in detail: Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric N. Gas Other: 1 H:\Applications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Page 1 of 2 '` Indicate type of mechanical work being installed and the quantity below: Unit Type Qty .' Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater 14 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty; Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct 14 Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial iUnIt-Type Qty Fire damper Diffuser Thermostat Wood/gas stove 14 Emergency generator Other mechanical equipment ., Byf 1 Boiler /Compressor r, F •. YM i'4tA� 1�Qty +e, s �a i 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 14 50+ hp /1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR UTHORIZED AGENT: Signature: Print Name:IJB55 Z &/7 /77 Ue c e C Mailing Address: OZ 5 S .6 + a, c I/ S4- H:\Applications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8- 9- 11.docx Revised: August 2011 bh Date: a Day Telephone: 2-06).7 0 G/ - iO /d S i- 14/4 ? 7/ V City State Zip Page 2 of 2 i • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 -431 -3665 Web site: http: / /www.TukwilaWA.gov Parcel No.: 2954900460 Address: 6955 FORT DENT WY TUICW Suite No: Applicant: HOMEWOOD SUITES RECEIPT Permit Number: M12 -120 Status: PENDING Applied Date: 08/29/2012 Issue Date: Receipt No.: R12 -02485 Payment Amount: $489.81 Initials: WER Payment Date: 08/29/2012 11:48 AM User ID: 1655 Balance: $0.00 Payee: JESSE LEMBECKER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 020086 ACCOUNT ITEM LIST: Description 489.81 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 391.85 000.345.830 97.96 Total: $489.81 doc: Receiot -06 Printed: 08 -29 -2012 -14 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 1Z- (206).431 -3670 Permit Inspection Request Line (206) 431 -2451 1 Project: Po ukovo)a Si Tref Type of I s ection: i r.. Address- Oefkl- Date Called: ktoJlt\ ieCo41 Special Instructions: Date Wanted a.m. p.m: Requester: - Phone No Er. fApproved per applicable codes. 0 Corrections required prior to approval.' COMMENTS: 1 nor)$r 1U Jrap Inspect tjv�� Date: REINSPECTION FEE REQUIRED. Prior to next-i`nspection >fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection -, 4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (Z (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: froN1� DA SL S Type ofylnspection: ip(fi . /LJe9I* M Address: CO �.,_ -_ O L /�,� .�f ) Date Called: il.c_JV 'c ,, r . CJ kr , oAl Special Instructions: 1 1 S 1 Date Wanted:. ( <11-7 1.% .m. Requester: Phone No: () t< - OJ J(t4- `T it EApproved per applicable codes. Corrections required prior to approval. 7 e COMMENTS: n 1* 1 1 S 1 1 S/1 /75 ' Dii-1 () t< - OJ J(t4- `T it 1 Z( 1 5( 1 YI Inspector w U n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: (' 7144- INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.:. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 :(206) 431 =367 Permit Inspection Request Line (206) 431 -2451 Proj ct: r �-JIQ Fkiv () d S rs Type of Inspection:. (coj6 .- r—J , Addt0 (5 {"Of"—F-D Date ailed: f. --= 0 il Special Instructions: Date Wanted:. r .; " ...,a; m.. Requester: - Phone No: 1 Approved per applicable codes. ,® Corrections required prior to approval. COMMENTS: re A-A -, r.S r it} t r� Inspet ctor: 1 a`7 U!. n REINSPECTION FEE REQUIRED. Prior to next inspection; fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule:reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: '1 4•-1 C AA.< co s h .CG Type of Inspection: 4 C 11 Cn I- - k. ) - g Address: (eici SS t-a p c)Fxrr Datq..Calle : t . r --...3 1 Lei-{ '4 V 41 • 9 r il Special Instructions: • Date Wanted:. I 1n- 1q-t-12— P.m. Requester: I RO O G Phone No: ,1-6(2-26------32i-f(_, 4 ElApproved per applicable codes. E Corrections required prior to approval. •t COMMENTS: I =PC - g of r il � r S- S (o I RO O G .V\ 1(1 141 4 /Y7/( ' / t Inspectgr: } I Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. *; INSPECTION RECORD Retain a copy with permit - INSPECTION NO. PERMIT NO. G CITY OF TUKWILA BUILDING DIVISION 6300: Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection, Request Line (206) 431 -2451 1. - VIA 1-2 Project: ' _ ? X1-1-0 -4M1E_ ti:StAct . CsL1s kP<' Type of Inspection: • knlc, k - 7 Address:, = Cct`5q i car- `Cf' Date CCai/: ,_ lled 1 C, -ti `D Special Instructions: Date Wanted:. 1O -1Z-t2 a:6 p.m. Requester: Phone No: - 2fYr 2 ‘S-- ! Z.4 {.., a Approved per applicable codes. COMMENTS: Corrections required prior to approval. f 0 / -4t.; ■4 1414 r \4i 11_ Insp ctor Datei / r REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 \)2-1-a,CT Project: 14 0rvlc5c.3 Fri I Ca-CS Type of Inspection: CIMA(.0 rl -.�1J Address: I 5 Date. ,if- , p Special Instructions: Date Wanted:. (0 — j-- 12- (a.m: p.m. Requester: Phone No: ,.0 6 -z-S5 - 324 - /(.., Approved per applicable codes. Corrections required prior to approval. COMMENTS: U9' i49 1'18 16 4 et\r 1 Inspect(: cu, Dati:0 V t n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. �t3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 \ (206) 43.1 -3670 Permit Inspection Request Line (206) 431 -2451 Project: H noAf,.W(x t] St citE S Type of Inspection: rRO t co t-t ^-I (� .. Addess: ,- Date Called: t >( Special Instructions: Date Wanted:. — 2-6n_ l2 /a'.m C p.m. Requester: Phone No: %^/ !y U aApproved per applicable codes. COMMENTS: El Corrections required prior to approval. • 1/A. ti((( /4c3i ,r7(o A Inspe lo,r) Dater, n REINSPECTION FEE REQUIRED. Prior to next inspection; fee must-be- paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISIO N 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431 - 3670.. Permit Inspection Request Line (206) 431 -2451 - 772/2 - /2-0 Project: /4/0/7166(/06,13 L5."2i1 TES Type of Inspection: /-) ) /1.�H ------ - Address: 6,q..1.5 ,U /? l ;t3,4'/ 7 Date Called: I< Special Instructions: C�l�2.73'9 -0 / Date Wa ed:. 9 /q- / a`m. p.m. Requester: Phone No: -2-06 .265-32 /S ,❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: JM J1c7� ) -r1 rj InspTor: 1\ ti.......�....- -r , \ n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection:: Date: INSPECTION RECORD Retain a copy with permit INSPECT! N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION L 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 =3670 Permit Inspection Request Line (206) 431 -2451 Mr" :2-c Project: TypegtInspection: Address: Date Called:i� -(� Special InstSructions: ivA 2eD - F.A 2s s - 3 Z4 2 Requester: / Date Wantte?d:. /a.m. Phone No: ic ❑ Approved per applicable codes. D Corrections required prior to approval. COMMENTS: A-grn (v v 111 47-4 4 ?-,, 1 , .A__p 6c4E. L" '7 Inspector: LkI\ n REINSPECTION FEE REQUIRED. Prior to next inspection, .fee must be, paid at 6300 Southcenter Blvd., Suite 100. Call to schedule'reinspection: Date: LENNOX H EAT PUMP OUTDOOR UNITS 13HPX ERITP Series R =410A ENGINEERING DATA REVIEWE CODE COMPLI APPROVED SEP 0 7 2012 City of Tukwila BUILDING DIVISION E MODEL NUMBER 1DENTIFICATION;_ Nominal SEER Unit Type HP = Heat Pump Outdoor Unit Bulletin No. 210566 June 2010 Supersedes March 2010 SEER up to 14.5 1.5 to 5 Tons Cooling Capacity - 18,000 to 58,500 Btuh Heating Capacity - 16,800 to 57,000 Btuh 13 HP X- 024- 230-2 T T Refrigerant X = R-410A Minor Revision Number Voltage 230 = 208 /230V -1 phase -60hz Nominal Cooling Capacity RECEIVED 018 =1.5 tons CITY OF TUKWILA 024 = 2 tons 030 = 2.5 tons 036 = 3 tons AUG 2 9 2012 042 = 3.5 tons 048 = 4 tons 060 = 5 tons PERMIT•CENTER FEATURES CONTENTS AHRI System Matches 10 Dimensions 7 Electrical Data 6 Features 2 Field Wiring 8 Installation Clearances 8 Model Number Identification 1 Sound Data 8 Specifications 6 EQUIPMENT WARRANTY Compressor - limited five year warranty in residential installations and five years in non - residential installations. All other covered components - five years in residential installations and one year in non - residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPLICATIONS SEER up to 14.5. HSPF (Region IV) up to 8.70. 1.5 through 5 tons. Single phase power supply. Sound levels as low as 76 dB Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof. Designed for applications with remotely located indoor air handler units or gas fumaces with indoor add -on coils. When heat pumps are used with gas furnaces, a dual -fuel control (i.e. FM21) or a control system with dual -fuel capabilities (i.e. Harmony III TM , LZP -2 or LZP- 4) must be used (ordered extra). See Indoor Coils and Air Handlers sections for indoor unit data. Units shipped completely factory assembled, piped and wired. Each unit is test operated at the factory insuring proper operation. Installer must set outdoor unit, connect refrigerant lines and make electrical connections to complete job. For expanded ratings, see www.lennoxdavenet.com. 13HPX -1.5 to 5 Ton Heat Pump / Page 2 APPROVALS Certified in Accordance withdhe-USE certification program, which is basedonAHRI'Standard 210/240- 2008. 33p Auq Mo3 3OO, Sound rated in Lennox reverberantrsound test loom in Accordance with test conditions included in AHRI Standard 270 -2008. WIS (; cEi? Tested in the Lennox Research Laboratory „ environmental test room. Rated According to U.S_!�Department�ofEnergy(DOE) • test procedures. °)Epovii gay Units and components within bonded for grounding to meet safety standards for servicing required by UL, NEC and CEC. Units are UL listed and CSA certified. ISO 9001 Registered Manufacturing Quality System. REFRIGERATION SYSTEM R-410A Refrigerant Non - chlorine, ozone friendly, R -410A. Unit is factory pre - charged with refrigerant. See Specification table. Total system refrigerant charge is dependant on outdoor unit size, indoor unit size and refrigerant line length. Refer to Installation Instructions for "Indoor Unit Match - Up and Sub - Cooling Charge Levels" to determine �correct a mount�of charge reeqquuired.1 .� r. FEATURES REFRIGERATION SYSTEM (CONTINUED) 0 Outdoor Coil Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling and heating capacity. Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs. Fan motor has sleeve bearings and is inherently protected. Motor totally enclosed for maximum protection from weather, dust and corrosion. Rain shield on motor provides additional protection from moisture. Louvered steel top fan guard furnished as standard. Fan service access accomplished by removal of top panel. ® Copper Tube /Enhanced Fin Coil Lennox designed and fabricated coil. Ripple -edged aluminum fins. Copper tube construction. Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer. Fin collars grip tubing for maximum contact area. Flared shoulder tubing connections /silver soldering construction. Coil is factory tested under high pressure to ensure leakproof construction. ® Steel louvered panels provide complete coil protection. Panels can be completely removed for servicing. 0 Expansion Valve - Outdoor Unit Designed and sized specifically for use in heat pump system. Sensing bulb is located on the suction line between the reversing valve and the compressor to sense evaporator suction temperature in any cycle. Factory installed and piped. High Pressure Switch Protects the system from high pressure conditions that can be a result of fan failure or a blocked /dirty coil. Automatic reset. Loss of Charge Switch Helps protect the compressor from damage due low refrigerant charge conditions. SPST, normally - closed switch, automatic reset switch mounted on suction line. High Capacity Liquid Line Drier Factory installed in the liquid line, the drier traps moisture or dirt that could contaminate the refrigerant system. 100% molecular- sieve, bead type bi -flow drier. © Reversing Valve 4 -way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. Valve operates on pressure differential between outdoor unit and indoor unit of the system. Factory installed. OPTIONS Check/Expansion Valve Kits Must be ordered extra and field installed on certain indoor units. See Thermal Expansion Valves (TXV) table. Chatleff -style fittings. Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean. Lines are cleaned, dried, pressurized and sealed at factory. Suction line fully insulated. Lines are stubbed at both ends. Not available for -060 models. Must be field fabricated. 13HPX -1.5 to 5 Ton Heat Pump / Page 3 FEATURES COMPRESSOR © Scroll Compressor .- Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Muffler in discharge line reduces operating sound levels. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Compressor Crankcase Heater (Factory installed on - 042 - 048 -060 models) Protects against refrigerant migration that can occur during low ambient operation. OPTIONS Compressor Crankcase Heater (Optional for -018 - 024 - 030 -036 models) Protects against refrigerant migration that can occur during low ambient operation. Compressor Sound Cover A reinforced vinyl compressor cover containing a 1 -1/2 inch thick batt of fiberglass insulation. All open edges are sealed with a one -inch wide hook . and loop fastening tape. 13HPX -1.5 to 5 Ton Heat Pump / Page 4 CABINET Heavy gauge steel cabinet with five station metal wash process. Louvered heavy gauge steel panels surround unit on all four sides to prevent damage to the coil. Powder paint finish provides superior rust and corrosion protection. Painted base section. Control box is conveniently located with all controls factory wired. Corner patch plate allows access to compressor components. Drainage holes are provided in base section for moisture removal. © Refrigerant Line Connections, Electrical Inlets, Service Valves Sweat connection vapor and liquid lines are located on comer of unit cabinet. Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Vapor valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system. Refrigerant line connections and field wiring inlets are located in one central area of cabinet for easy access. See dimension drawing. OPTIONS Mounting Base Provides permanent foundation for outdoor units. High density polyethylene structural material is lightweight, sturdy, sound absorbing and will withstand the rigors of the sun, heat, cold, moisture, oil and refrigerant. Will not mildew or rot. Can be shipped singly or in packages of 6 to a carton. Unit Stand -Off Kit Black high density polyethylene feet are available to raise unit off of mounting surface away from damaging moisture. Four feet are furnished per order number. /. FEATURES CONTROLS © Defrost Control Solid -state time /temperature defrost control is furnished as standard equipment. Control initiates a defrost cycle every 30, 60 or 90 minutes of compressor "on" time at outdoor coil temperatures below 42 °F (factory setting 90 minutes). Anti -short cycle, timed -off control incorporated into the board. High and low pressure switch monitoring with five -trip lockout. Diagnostic LED's furnished as an aid in troubleshooting. Conveniently located in control box. OPTIONS Compressor Hard Start Kit Single -phase units are equipped with a PSC compressor motor. This type of motor normally doesn't need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. Compressor Low Ambient Cut -Off Non - adjustable switch (low ambient cut -out) prevents compressor operation when outdoor temperature is below 35 °F. Freezestat Installs on or near the vapor line of the indoor coil or on the suction line. Senses suction line temperature and cycles the compressor off when suction line temperature falls below it's setpoint. Opens at 29 °F and closes at 58 °F. Indoor Blower Off Delay Relay Delays the indoor blower -off time during the cooling cycle. See AHRI System Matches for usage. Low Ambient Kit Heat pump in the cooling mode will operate satisfactorily down to 45 °F outdoor air temperature without any additional controls. Low Ambient Control Kit can be field installed, allowing unit operation down to 30 °F. Crankcase heater and freezestat should be installed on compressors equipped with a low ambient kit. A Compressor Low Ambient Cut -Off should be added to terminate compressor operation below recommended operation conditions. Low Pressure Switch Bypass Thermostat For use in applications where the heat pump is operated in outdoor ambient temperatures below 15 °F. Prevents nuisance trips from the low pressure switch. Wired in parallel with the low pressure switch. Mild Weather Kit Heat pump units operate satisfactorily in the heating mode at outdoor air temperatures up to 75 °F. Mild Weather Kit can be field installed, allowing heating operation above 75 °F. Monitor Kit - Service Light Contains ambient compensating thermistor and service light thermostat. For use with thermostats requiring input for indicator lights. Outdoor Thermostat Kit An outdoor thermostat can be used to lock out some of the electric heating elements on indoor units where two stage control is applicable. Outdoor thermostat maintains the heating load on the low power input as long as possible before allowing the full power Toad to come on the line. Thermostat kit and mounting box must be ordered extra. Thermostat Thermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book. 13HPX -1.5 to 5 Ton Heat Pump / Page 5 SPECIFICATIONS General Model No. Data Nominal Tonnage 13HPX -018 13HPX -024 13HPX -030 13HPX -036 13HPX -042 13HPX -048 13HPX -060 1.5 2 2.5 3 3.5 4 5 Connections Liquid line o.d. - in. (sweat) Vapor line o.d. - in. 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/4 3/4 3/4 7/8 7/8 7/8 - :- 1=118 ' Refrigerant (R -410A) furnished 7 lbs. 1 oz. 6 lbs. 8 oz. 7 Ibs.11 oz. 6 lbs. 5 oz. 9 lbs. 8 oz. 11 Ibs.11 oz. 13 Ibs. 12 oz. Outdoor Net face area Outer coil Coil sq. ft. Inner coil 15.21 15.21 13.30 15.21 18.66 21.11 24.50 - - - - - - 12.60 14.50 17.95 20.31 23.56 Tube diameter - in. Number of rows Fins per inch 5/16 5/16 5/16 5/16 5/16 5/16 5/16 1 1 2 2 2 2 2 22 22 22 22 22 22 22 Outdoor Diameter - in. Fan Number of blades Motor hp Cfm Rpm Watts 18 18 18 18 22 22 22 3 3 4 4 4 4 4 1/5 1/5 1/5 1/5 1/3 1/3 1/4 2400 2400 2400 2450 3800 3800 3830 1130 1130 1095 1100 1100 1100 825 175 175 194 180 360 360 330 Shipping Data - lbs. 1 package 160 160 170 180 225 250 264 ,ELECTRICAL DATA <':.; Line voltage data - 60 hz - 1 ph 2 Maximum overcurrent protection (amps) 3 Minimum circuit ampacity 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 208/230V 20 30 30 35 40 50 60 12.4 18 18.7 22 25.3 29 34.6 Compressor Rated Toad amps Locked rotor amps Power factor 9.0 13.5 14.1 16.7 18.8 21.8 26.3 39 53 59 70 90 100 120 0.96 0.97 0.98 0.98 0.94 0.95 0.98 Outdoor Full load amps Fan Motor Locked rotor amps O_................-__.• IOAL ACCESSORIES. _ MUST Compressor rankcase Heater 93M04 1.1 1.1 1.1 1.1 1.7 1.7 1.7 1.9 BE • 1.9 ORDERED 1.9 EXTRA 1.9 _ 4.1 Factory 4.1 Factory 3.1 Factory Compressor Hard Start Kit 10J42 88M91 • • • Compressor Low Ambient Cut-Off 45F08 • • • • Compressor Sound Cover 69J03 • Freezestat 3/8 in. tubing 93G35 5/8 in. tubing 50A93 • • • • • Indoor Blower Off Delay Relay 58M81 • • • Low Ambient Kit 54M89 • • Low Pressure Switch Bypass 13W07 Thermostat • • Mild Weather Kit 33M07 • • • • Monitor Kit - Service Light 76F63 • • Mounting Base 69J06 69J07 • • • • • Outdoor Thermostat 56A87 Thermostat Kit Mounting Box 31461 • • • • • • Refrigerant L15- 41 -20, L15- 41 -30, Line Sets L15- 41-40, L15 -41 -50 • L15- 65 -30, L15- 65-40, L15 -65 -50 • Field Fabricate • Unit Stand -Off Kit 94J45 • • NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage. ' Refrigerant charge sufficient for 15 ft. length of refrigerant lines. 2 HACR type circuit breaker or fuse. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. • Crankcase Heater and Freezestat are recommended with Low Ambient Kit. 13HPX -1.5 to 5 Ton Heat Pump / Page 6 DIMENSIONS - INCHES (MM) INLET AIR TOP VIEW INLET a AIR SUCTION LINE ■CONNECTION LIQUID LINE CONNECTION OPTIONAL UNIT STAND -OFF KIT (4) (Field Installed) COIL DRAIN OUTLETS 0 (Around perimeter of base) �L ELECTRICAL INLETS 6 -3/8 (162) OUTDOOR COIL FAN COMPRESSOR CdMPRES4R 0) 14:118) 1 6 -3/8 (162) TOP VIEW BASE SECTION A DISCHARGE AIR SUCTION AND LIQUID LINE CONNECTION \ 2 -3/4 (70) tacM _I JIMMI .c IMIMS _ AIROW MINIM MY • 1•I OPTIONAL UNIT STANDOFF KIT (4) (FIELD INSTALLED) Li SIDE VIEW Model No. A B C inches mm inches mm inches mm 13HPX-018 13HPX -024 13HPX -036 24 -1/4 616 33 -1/4 845 32 -1/2 826 13HPX -030 24 -1/4 616 29 -1/4 743 28 -1/2 724 13HPX -042 28 -1/4 718 33 -1/4 845 32 -1/2 826 13HPX -048 28 -1/4 718 37 940 36 -1/4 921 13HPX -060 28-1/4 718 43 -1/4 1099 42 -1/2 1080 13HPX -1.5 to 5 Ton Heat Pump / Page 7 SOUND DATA 1 Unit Model No. Octave Band Sound Power Levels dBA, re 10-12 Watts Center Frequency - HZ ". 'Sound Rating Number (dB) 125 250 500 1000 2000 4000 8000 13HPX -018 70.5 67 68 67 65.5 60.5 57.5 76 13HPX -024 67.5 66.5 69.5 70 66.5 60.5 56 76 13HPX -030 70.5 69.5 71.5 72.5 67.5 63.5 60 76 13HPX -036 69.5 70.5 71.5 69.5 68.5 62.5 60.5 76 13HPX -042 75.5 79.5 79.5 75.5 70 63.5 58.5 80 13HPX -048 75.5 74.5 75 73.5 70 66.5 63.5 80 13HPX -060 79 75 75 73 69.5 64.5 58 80 NOTE - the octave sound power data does not include tonal cor ection. ' Tested according to AHRI Standard 270 -2008 test conditions. FIELD WIRING !DISCONNECT' I SWITCH I 113y Others) I OPTIONAL I THERMOSTAT LENNOX OUTDOOR UNIT 1 OPTIONAL I ELECTRIC HEAT I LENNOX INDOOR UNIT DISCONNECT SWITCH (lay Others) I THERMOSTATI (Optional) C A - Two Wire Power (see Electrical Data) B - Two or Three Wire Power (size to heater capacity) C - Twelve Wire Low Voltage 18 ga. minimum Fourteen Wire Low Voltage with Optional Outdoor Thermo- stat D - Eight Wire Low Voltage 18 ga. minimum Ten Wire Low Voltage with Optional Outdoor Thermostat NOTE - Field Wring Not Furnished All wiring must conform to NEC or CEC and local electrical codes. 13HPX -1.5 to 5 Ton Heat Pump / Page 8 °INSTALLATION CLEARANCES M) 4 See NOTES CONTROL See NOTES BOX / NOTES: Service clearance of 30 in. (762 mm) must be maintained on one of the sides adjacent to the control box. Clearance to one of the other three sides must be 36 in. (914 mm) Clearance to one of the remaining two sides may be 12 in. (305 mm) and the final side may be 6 in. (152 mm). A clearance of 24 in. must be maintained between two units. 48 in. (1219 mm) clearance required on top of unit. • • PERMIT CO copy PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -120 PROJECT NAME: HOMEWOOD SUITES SITE ADDRESS: 6955 FORT DENT WY X Original Plan Submittal Response to Correction Letter # DATE: 08 -29 -12 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ing Division Public Works ti4I� F kk Ire Preven ion am Structural Planning Division Permit Coordinator n iN DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 5-ct Incomplete DUE DATE: 08 -30 -12 Not Applicable Comments: Permit Center Use OnIy INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09-27 -12 Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center` Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents /routing slip.doc 2 -28-02 Contractors or Tradespeople Peer Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name GREENWOOD HEATING & A/C UBI No. 602259014 Phone 2063653313 Status Active Address 2850 Sw Yancy St Pmb 203 License No. GREENHA922U7 Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/27/2008 State WA Expiration Date 2/3/2013 Zip 98126 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Associated Licenses License Name yP Type Specialty 1 P y Specialty 2 y Effective Date Expiration Date Status SELECAS972BW SELECT AIR SERVICES INC Construction Contractor Air Conditioning Metal Fabrication 1/16/2003 1/16/2005 Archived GREENAS952CC GREENWOOD AIRE SERV Construction Contractor Air Conditioning Unused 2/3/2005 2/3/2009 Inactive Business Owner Information Name Role Effective Date Expiration Date PORTER, MICHAEL Owner 03/27/2008 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 CBIC SI4989 01/14/2010 Until Cancelled $12,000.0001/13 /2010 3 HARTFORD FIRE INS 45BSBEZ5127 03/21/2008 Until Cancelled 03/21/2010 $12,000.0003/27 /2008 2 FIRE INS CO 45BSBEJ2369 45BSBEJ2369 01/14/2007 03/21/2008 $6,000.0005/21/2007 3 1 HARTFORD FIRE INS 45BSBBZ8401 01/14/2003 Until Cancelled 05/03/2007 $1,000,000.0001 /09/2006 $6,000.0001/16/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Mid-Century Ins 604663707 08/01/2008 08/01/2013 $2,000,000.00 07/06/2012 5 NATIONWIDE MUTUAL INS CO ACPACT0712203883601/15/2008 01/15/2009 $1,000,000.00 01/07/2008 4 AMCO INS CO ACT07102038836 01/15/2007 01/15/2008 $1,000,000.0001 /11/2007 3 ALLIED INS 104711 01/15/2005 01/15/2007 $1,000,000.0001 /09/2006 Summons /Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions /Citations Information Infraction / Citation I Date 1 RCW Code Type ] Status I Violation Amount1 https://fortress.wa.gov/lni/bbip/Print.aspx 09/11/2012