Permit M12-143 - WESTFIELD SOUTHCENTER MALL - VERIZON
VERIZON WIRELESS 132 SOUThCENTER MALL M12 -143 Parcel No.: Address: City &Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 -431 -3670 Inspection Request Line: 206 - 431 -2451 Web site: http: / /www.TukwilaWA.gov MECHANICAL PERMIT 9202470010 132 SOUTHCENTER MALL TUKW Project Name: VERIZON Permit Number: M12 -143 Issue Date: 10/16/2012 Permit Expires On: 04/14/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: Address: Email: ANDREA VANBARICOM 5005 3 AV S , SEATTLE WA 98134 ANDIV @MCKINSTRY.COM Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98124 Contractor License No: MCKINCL942DW Phone: 206 396 -1979 Phone: 206 762 -3311 Expiration Date: 03/16/2014 DESCRIPTION OF WORK: INSTALL (1) TON MOVINCOOL UNIT INTO THE CEILING IN THE IT ROOM. THIS UNIT IS LIKE A VAV BOX WITH A CONDENSOR COIL. Value of Mechanical: $10,000.00 Type of Fire Protection: SPRINKLERS /AFA Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied The granting of this permit does not pres construction or the performance of work. back of this emit. Fees Collected: $306.06 International Mechanical Code Edition: 2009 Date: 01 [(A ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the '1 Signature /"J + U JI ( z l V / Date: 1l) if /1.2 Print Name: P (\ct( 2- \QrcrNcRIoA It 1 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. doc: IMC -4/10 M12 -143 Printed: 10 -16 -2012 PERMIT CONDITIONS Permit No. M12-143 1: ** *BUILDING DEPARTMENT CONDITIONS * ** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431- 3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206- 431 - 3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M12 -143 Printed: 10 -16 -2012 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd.. Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: Ell Pi (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. * *please print ** SITE LOCATION Site Address: Tenant Name: ZD e tre_ke SS PROPERTY OWNER n c . Address: 5c , o owe_ l tJ J City: Sttate: iddf),i Zip: Giro_ Name: ti 1 e 1 � ` . wtril Address:?0 1 f Phone: 2,y co 7102_331 t Fax: Om. State: N City: O `sa_k Zip: C o"1' CONTACT PERSON — person receiving all project communication Vanal?-. C Name: CU X1(1 n c . Address: 5c , o owe_ l tJ J City: Sttate: iddf),i Zip: Giro_ Phone: Q ` 0_'eolax: 11,A Email: /� ,rx ,ei� �% ( ( r)6( r% uN.CT' \ 0 King Co Assessor's Tax No.: q 202, 41 co 0 Suite Number: 13 a Floor: New Tenant: El Yes ..No MECHANICAL CONTRACTOR INFORMATION / Company Name: �'� `Cl tip Address: 5 2 r&1 SU _ l�� City: . 1 i State: Zip:q � 2l V Phone: 2,y co 7102_331 t Fax: Om. Contr Reg No.: m e x p o \ C L s I p a r 31ItP Tukwila Business License No.: B 1. _ 01 01q (3 Valuation of project (contractor's bid price): $ /0100a Describe the scope of work in detail: 1(Pai� � MOM eta U4i4 VOLD tka2 eat" n UJ CA. \J A') v304 WJ- 0. eo O M Q Use: Residential: New ❑ Commercial: New Fuel Type: Electric Liz Replacement Replacement cQL, soft_ cuti-tzehzoo Gas ❑ Other: H: Applications\Fotnis- Applications On lane \201 I Applications\Mechanical Permit Application Revised 8 -9 -1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system O Air r handling unit <10,000 cfm (4) Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler /Compressor Qty 0 -3 hp /100,000 btu 3 -15 hp /500,000 btu 15 -30 hp /1,000,000 btu 30 -50 hp /1,750,000 btu 50+ hp /1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: E1R 2 OR01 RIZED A NTI: V:P/ t / Print Name: PtlYt Yfk V (Q -401 Mailing Address: H:\Applications\Forms- Applications On Line \2011 Applications\Mechanical Permit Application Revised 8 -9 -1 l.docx Revised: August 2011 bh Date: Tilt 261 Day Telephone: 2.0(0 IU di - Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M12 -143 Address: 132 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 09/17/2012 Applicant: VERIZON Issue Date: Receipt No.: R12 -02631 Payment Amount: $306.06 Initials: LAW Payment Date: 09/18/2012 09:37 AM User ID: 1632 Balance: $0.00 Payee: MCKINSTRY CO TRANSACTION LIST: Type Method Descriptio Amount Payment Check 12199 306.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 244.85 000.345.830 61.21 Total: $306.06 doc: Receiot -06 Printed: 09 -18 -2012 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION `. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 , (206) 431- 3670 Permit Inspection Request Line (206) 431 -2451 5- MiZ'1 Projest�:%e /-. Type of Inspection. Addre s : Date Called: Special Instructions: )s 4441 Cat 3 0 � , Date Wanted:. a.m. Requester: Pho«-n�e No: Approved per applicable codes. Corrections required, prior to'approvali COMMENTS: D-eJ c4 A Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee.must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule.reinspection INSPECTION RECORD Retain a copy with permit INSPECTION NO. - PERMIT NO. CITY OF TUKWILA BUILDING DIVISION - 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 -3670 Permit Inspection Request Line (206) 431 -2451 Project: Type of Inspection: Address: 1 -3 7. Wk6it Date Called: Special Instructions: 0 ill If Atifk..D 01--11-12.q —0 1 Date Wanted:. 11 121)1? (a"m. pun Requester: — ef01 Awl Phone No: - / ao.-2 Ts -7,?1 -(. - - ElApproved per applicable codes. Corrections required`prior to;approval. COMMENTS: AvkieelPITh Inspector: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must;be : paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.— There is a AHU in the space behind the telco room that has a condensate piping that we will tap into. FLOOR DRAM pule* pxnl (IYP) FILE COPY Pen?* ova MO, -I x-1,3 Plan review Approval of the v 3lation of any el approvedtTeld Copy arkjc n!lPsackn IP y TORY C R By Date: 2 °t 2_ City Of Tukwila BULLING DIVISION APPROXIMATE LEASE UM LOCATION -- - SALES DESK (rm.) 8' HiS44 PERM-TER S PROMO BRUNO DISPLAY HAVRE SEPARATE PERMIT REQUIRED FOR Mathanical PROPOSED SOffff AWE MP) Electrical • Plumbing g, Gas Piping City of Tukwila BUILDING DIVISION I 4 0 i -. 1.O OXI TE LEASE LICE ..w U k �-o p \c tai Q_Jcisi;c-f6 U at P `pmt.. C562 Oic:fikee51.) CUSTOMER SERVICE SALES 'CARPET 7 RETAIL SAL1 1- I j ---'------ REVIEWED FOR CODE COMPLIANCE APPROVED OCT 12 2012 I L PROPOSED UY 51ff . puns (rtv) 1- J 2-BAY M OS MERGWCISE DISMAY MOVE PROPOEED GYP) SOUTH CENTER MALL VERIZON WIRELESS - SEATTLE, WA PROPOSED FLOOR PLAN 2;401 SF STS. I -14 -OS 112' THICK, 6LA55 WIRY DOORS J City of u ila BUILDING (VISION CUSTOMi. SELF UECK -IN FDOWE MALL N9lIRAL PIM TO RBMWN (iYP. OF 2) PROPOSED V1' THUG CIE* TEMPERED fi AWLESS 61ASS ON 15/4' FIDE BY 6'H6NBRIL9IE7 VIED. STOREFRONT r1TAME (1YP). APPROVED: DATE: COMMENTS; SR 4-5-07 K6 COMMENTS; 11- 14-07 fNCOMP�ETE tlt I �� LTR# REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will regiiiro a new plan submittal and may include additional plan review foes. RECEIVED CITY OF TUKWILA OCT 0 3 2012 PERMIT CENTER 00 CO o N Cf LL W_1 1 g. LL Ct I CD h I PROD. 2007 -0071 DRWN, JMR,EMG,MP DAZE AS NOTED SHEET SK4 RECEIVED CITY OF TUKWILA OCT 0 3 2012 PERMIT CENTER Portable Air Conditioners, AC, Spot Cooler, Outdoor & Computer Cooling MOVI NCOOL. THE #1 SPOT COOLING SOLUTION ' PORTABLE AIR CONDITIONERS CEILING MOUNTED A/C CM12 10,500 Btu /h at 80 °F 50% RH (Evaporator) & 95 °F 40% RH (Condenser) 13,000 Btu /h at 95 °F 60% RH 115V, 15 amps - no special electric required No floor space needed Fits into tight ceiling spaces - only 15.5" tall. Product Information Product Features Specifications Cooling Capacity ,,,•'' FIL4COPY Permit No. Page 1 of 2 APPLICAT IS DEALER LOCATOR .CUSTOMER SUPPORT Application Environment Rating Conditions: 95 °F at 60% RH 10,500 Btu /h 1'2 Accessories Specifications Electrical Characteristics Voltage Requirement Total Power Consumption Current Consumption Recommended Fuse Size NEMAPIug Configuration Min. Max. Voltage 1 Phase, 115V 1.23kW1.2 11.9 amps 1,2 15 amps N/A 105 - 125 Fans Motor Output 0.04/0.013 kW Evap. 0.1/0.025kW Cond. Evaporator FanType Max.Air Flow high /low Max.External Static Pressure Condenser FanType Max.Air Flow high /low Max.External Static Pressure Compressor Refrigerant Dimensions Type Output R -410A Centrifugal 324/228 CFM 1 0.16 IWG Centrifugal 700/370 CFM 0.12 IWG Hermetic Rotary 0.89 kW 1.141b Wx DxH 35x23x15.5in Net Weight/Shipping Weight 128/141 lb Power Cord Gauge Length N/A N/A Condensate Tank Auto Pump Included p� Capactty P ERMIT C+EIR R CITY SEP 17 2012 D. FOR CODE COMPLIANCE APPROVED City of Tukwila pIVISION $2,895.00 FIND`A DEALER a select Downloads for CM12 Case Study Operation Manual I' Sparc Parts Catalog I =1 Sales Sheet Service Manuals Specifications Standard Warranty I=�1 http://www.movincool.com/portable-air-conditioner/cm12.php M I2 -KO ronarie Air uonuitioners, AL, spot Cooler, Outdoor & Computer Cooling Page 2 of 2 Operating Conditions Min. - (@ 50% RH) O 1� 65° - 95° F (Evaporator) 1 65° - 113° F (Condenser) 1 Max. Duct Length Per Cold Duct Hose* "';:z: Max.,Sound Level " HotDuct Hose 120 ft 3 10ft3,rt. Home 1 Portable Air Conditioners 1 Ceiling Mounted A/C 1 Applications 1 Dealer Locatt With Condenser - Duct high /low 52 dB(A). Without Condenser - Duct high /low NA /NA 1 Customer Support 1 About Us 1 Authorized Dealer: , 1 Measured with two 6 ft ducts with one 90' bend each, supply grill and return grill with filter (0.16 IWG extemal static pressure) (ducts'not Included) 2 Confirm pressure drop of duct, grills and filter with manufacturer's specifications (ducts not included) A dlvltlloat of DENS° Corpo ratlo 14 104 DENSO North America bail$tte MovinCool, SpotCool and Office Pro are registered trademarks of DENSO Corporation. © 2012 DENSO Sales California, Inc. AJMIAI http://www.movincool.corn/portable-air-conditioner/cm12.php {° • 8/28/2012 INCOMPLETE -11),(D-ci LTR #_ 4f ' swii\rwt 0 tit 1 t OCT 0 3 2012 PERMIT CENTER INCOMPL LTR# ECEIVED OF TUKWILA CT 0 3 2012 MIT CENTER b ■Ye \9eOt-rEN' MDRB -1: SEISMIC RIGID BRACING: OPEN WEB STfHF , , o v Pl,- - 1 /2'HEX801T t 6'A41X - L ni k-g ar beam vod RuT Wcurn • ' , MDRB -2: RE �IANCE ODE PPROVED OCT 1.2 2012 City NG 008 - BU1LD — TE 7) CO NOM DOUBLE STRUT DIV9 N win # GUMMY PLOD BRACE AS NOTED ON DETAIL PAGE 1 AS REDS} 1/2' ED( ELT A325 (LENGTH AS REQUIRED) 1 1/r HX KR A325 1 1/2' LDCK WASHER A307 1 SQUARE RATE ASV 2'7.2'x0.195' GALV 2 SWAY ATTACFOJENT LNSIRTIT SWUM, SPF2D0, SPF300 0 1/2 CR HUT SE19AC H}4 W/ HER HOLE METER TO SU.T PAGER RED 2 1/2' HD( BOLT LJ SIRUA CR ECM 4 1/2' CFNJIEL NJT LNS1RUE CR HUT MQM-F 4 CLNPCM3D3 MAY BE REPLACED WITH APPROVED MIS OF ECl1LL S1RERGIN. 2. OUMW 6 FOR ONE COMPLETE TRNOVE?t5E BRIAIG KO. MULTIPLY QUANTITY el 3 FOR IMMERSE AND LOIMJIUDROL E1RM' TABLE 3: MDRB -2 COMPONENTS CORCtENT FACCEL / QUANTBY PLOD BRACE AS NOTED ON DETAIL PAGE 1 AS MO 1/2' HEX ECU A325 (LENGTH AS REQUIRED) 1 1/2' HD NUT A325 1 1/2' LDCJ( WASIIR A307 1 SQLIA RE RATE WAR 2'7.2'x0.195' GALV 2 SWAY ATTPCUiIEM UNSO8JT SPFIO , SPF200, SPF300 0 5/8' CR HILT SELS3AC HNGE W/ Hit HOLE Db/AETER TO SST HANGER RCO 2 1/2' FEX BOLT UMSIRA' OR EQUil. 4 1/2' CHNA■EI NUT INSIRIJT OR Hill VCI -F 4 COYPlerS MAY C: REPLACED ITI1 APPROVED MIS OF EOM MERCK 2. OLYNDEY IS KR ONE COMPLETE 1FW6VERSE BRACING KR. MULTIPLY QUREi11Y BY 3 FOR TFON fSE AND LDRCTTUDBU1 CRAM GENERAL NOTES: 1. CONNECT SE15140 BRACING ONLY TO TOP CHORD OF CPEN WEB STEEL JOIST. 2. CONNECT SEISMIC BRACE WTTHIN 6 INCHES OF PANEL POINT. ALTERNATE LOCATIONS REQUIRE ADDITIONAL WELDED ANGLE SUPPORT STEEL. PER STRUCTURAL DRAWINGS AND JOIST MANUFACTURER. 3. DO NOT CUT OR DRILL JOIST MEMBERS 4. VERIFY POINT LOAD TO JOISTS IS ACCEPTABLE PER STRUCTURAL NOTES AND DETAILS. 5. CONNECTION TO STRUCTURAL STEP. SUBJECT TO PRIOR APPROVAL FRCM STRUCTURAL ENGINEER OF RECORD. 6. BRACE SPACING SrW1 BE SELECTED UTIUZJNG THE 'MCIQNSTRf OUCT HANGING AND BRACING' CALCULATOR. 7. TYPICALLY USE MORE -1 TO WAR PONT I.GAD ON OPEN WEB STEEL TRUSSES. ONLY USE MORE -2 IF STRUCTURAL DRAWINGS INDICATE SUFFICIE•L1LY NIGH ACC&TABIE PANT LOADS, OR IF POINT LOADS ARE COORDINATED WITH STRUCTURAL ENGINEER OF RECORD. 8. SEE PAGES 1, 2 & 3 FOR BRACE REQUIREMENTS. INCOMPLETE CMG REVOCk 03 -06-09 DETAIL CREATED 08 -04-11 DETAIL REVISION [CODE REVISION] MR I113 ins try BVGINEERNG Mechanical Contactors and Engineers 5005 3rd Ave South P.O.Box 24567 Seattle, Wo. 98124 phone (206) 762 -3,311 fax: (206) 762 -2624 5400 N£ Columbia Blvd Portland Or. 97218 fax (50 331-690.3 111 -6 mr.mckinsby corn OETNLPNE4CF11 Date: 8- 4-2011 Checked: DAV10 CARROLL Job: MCKINSTRY STANDARD LED ' '1A 'LPL; -�+SW I I A OCT 032012 PERMIT CENTER t)aQ MCKINSTRY DUCT RIGID BRACING SEISMIC DETAILS STRUCTURE - SEE PAGES 4 -2 FCR ACCEPTABLE STRUCTURAL ATTACHMENT METHODS t15' SEE NOTE 7 RIGID BRACE TRANSVERSE OR LDNGFUDINAL - ROD COUPLING o O 11 GRAVITY HANGER WITH 1 -5/8" STRUT CHANNEL 1i1 EN RE00 Swat ATTACHMENT FROM STRUT ` MANUFACTJRER Tf ?CAL AT CULT AND // STRUCTURE FOR TRANSVERSE AND LONGITUDINAL BRACES NUT & WASHER EACH SIDE CF TRAPEZE ANGLE TABLE 1: ALLOWABLE ERACE LOADS ROD STIFFENER CONN (2 MIN) 8 STRUT CHANNEL -WHEN RED (SEE TABLE 1 FOR SPACING) DUCT TRAPEZE SUPPORT ANGLE (SEE NOTE 3) (VP 2) Th6EADEG R00 (SEE TABLE 1) PO SELF TAPPING SHEETIAETAL SCREWS MAXIMUM 12' OC TOP AND EOTTOM TRAPEZE RECTANGULAR DUCT BRACING (ELEVATION) DETAIL MCKiNSTn BRACE TYPE ( RIGID BRACE 'EIGHT PER FT AT SPACE ,SPACING (LE /FT) CRAM HANGER ES140 RC4i CLAMP SPACNG 10 FT I 20 FT 30 FT 40 FT MORE -1 1 -5/0' x 1 -5/5' SIRJT 61.2 j 30.6 20.4 15.3 1/2' 12' MDR9 -2 1 -5/8' x 3-1/4 SIRJT 104-.4 ( 52.2 34.6 26.1 5/8' - 15' . USE 12 GA GAC5ABFZEO OR CAONIUM p44080 STRUT. 2. THE LB /FT YALUES NDICATZ3 IN TABLE 1 ARE DEANED 1S:NG F '.D. THE L9,011 2ALLE SIAM BEMCCB'E3 UT14 NG THE ?It L ATCN'MALLE 2012683 FRCV THE UEC4ANICAL S"4118 30I4N SHEET. VALUES ARE MCDFIED AS MUMS: (t /Fe /FT) =AU9W BLE BRACE LB/10. 3. COMPCNENT 4ZE5 CALCULAT D 154*0 ALL0W.'YSLE SIRES DESIGN (AS0). CENEPAL NOTES: 1. DC NOT MIX R'C ID BRACING 'NITH CABLE BRAC'NG 'N THE SANE CIPECT1ON ON ANY DUCT RUN. BRACING STYLE MAY CHANGE IN THE SAME RUN Vi -EN RIGID BRACING €S SEPA.RATE2 FROM RIGID BFACING BY A FLEYIELE DUCT CONNECTION. 2. SHE INETAL SHALL EE 00N5TRUC;00 0 THE MIN STANDARDS PRESCRIBED 'WITHIN THE 2005 SMACNA *VAC DUCT CONSTRUCTION STANDARDS MANUAL 3. BRACE SPACINC AND TRAPEZE SUFFOR' ANGLE SHALL BE SELECTED UTILIZING T -E 1AC\INSTRRY DUCT HANG NC AND 9R?G!JC' CALCULATOR. 4. "BRACE DESIGN SHALL EE CONSISTENT WITH T.E METHODS OUTLINED IN THE 'MCKINSTRY DUCT BRACING LAYOUT PROCEDURE". 5. CO NOT USE WITH '?ERATICN ISOLATED HANGERS WITH RCM BRACING 6. DESIGNED :N ACCCREANCE YP'H 2003 :EC AND ASCE 7 -05 CRITERIA. 7. BRACE MAY BE INSTALLED INWARD WHEN THE 0574140E FROM THE TOP OF DUCT TO STRUCTURE ALLOWS. PRCVICE SEPARATE STRUCTURAL 0011100 wh FCR RICO SEISMIC BRACE (00 NGT CONNECT TO GRAN1T( HANGER STRUCTURAL ATTACHMENT). OETAL PAGE 1 CF 11 DATE 9845846 03- -06-09 DETAIL CREATED 08 -04 -11 DETAL RE41S10N [CODE REVISION] 8'75 (ry ENGINEERING Mechanical Contractors and Engineers 5005 3rd Ave Sevth 0 8or 24557 Secure, Wa. 98124 phone (205) 752 -3.311 fax: (205) 752 -2524 5400 NE Columbia Blvd Portland, Or. 97218 phone (503) 331 -6903 fax (503) 331 -59123 www.mckinstry cam Date: Cnect,ed: ;� Jch: ►n: 3T'- I D 8 -4-2011 DET,0IITd/1NGIJ K W 1 L A WITH 3801 STRUCTURAL B'8N'EE8S OCT 0 2012 PERMIT CENTER -Q.QtrNt& OPNAlalshc>cy MCKINSTRY DUCT RIGID BRACING SEISMIC DETAILS STRUCTURE - SEE PAGES 4-9 FOR ACCEPTABLE STRUCTURAL ATTACHMENT METHODS 45' ±15' 1i ROD STIFFENER STRUT CDNN (2 MIN) 0 STRUT (SEE TABLE REQO (SEE iABlf 1 FOR SPACING) GRAVITY HANGER WITH 1 -5 /Br STRUT CHANNEL WHEN RECD RIGID BRACE TRANSVERSE OR LCNGINDINAL SWAY ATTACHMENT FROM STRUT MANUFACTURER TYPICAL AT DUCT AND STRUCTURE FOR TRANSVERSE AND LONGITUDINAL BRACES STRUCTURAL ATTACHMENT ROO CCUPUNG ----°-- THREADED ROD (SEE TABLE 1) NUT te WASHER EACH SIDE OF ROUND DUCT HANGER (SEE MCXINSTRf SHOP STANDARDS) STYLE A ROUND DUCT HANGER MCK FABRICATED IN ACCORDANCE WITH SMACNA STANDARDS ROUND DUCT BRACING ELEVATION VIEW DETAIL ROD CCUPUNG SEISMIC ROD CLAMP THREADED ROD CONNECT ON AT STRUCTURE THREADED R00 SEISMIC ROD CLAMP TRAPEZE OR DUCT HANGER CONNECTION AT HANGER/TRAPEZE HANGER ROD COUPLING DETAILS WM: Meat 03-06 -09 DETAIL CREATED 08 -04 -11 DETAIL REVISION )CODE REVISION1 WAIL PATE 2 CF 11 5005 3rd Ave South P.0.8ox 24567 in S ry Seattle, Wa 98124 fax (2 ) 762 -2624 Uechonical Contractors and Engineers 5400 NE Columbia 9Ad Portend Or 97218 phone (503) 331-6903 fax (503) 331 -6903 Nww.mcidnstry.com PERMIT CENTER i ;r 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Info /� /" � Project Address' ^ a3 ' 4_ wl Date G % i u 120i 2 1-1.k ., / 0 16 For Buildl/ng dept. Use "ttia`-1 Et) 't€LP s-_ c31 4.e : 15f3, Applicant NarK e -v ' V ..e\ �� �` `^ ^ Applicant Address: # 'J . �� ,r 9� „ t A'�" "" Applicant Phone: alp- 33" -` sr 1s � Project Description Briefly describe mechanical system type and features. ❑ Includes Plans umti,` a'�" -3�?MOAN/Mil 3 cok. ac&eQ. c -�.. -t (,,, c ` `� Y �nL,� n Lt r„f) �,�, 2 "`.J 'cox Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH -SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu /h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N t, v\ c (Lr*Q vWth\ arAcika 124,E m 1-:'►: 13 Pu ,k_aj lu/ Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu /h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N REVIEWED FOR I J/,t CODE COMPLIANCE APPROVED OCT 12 2012 Fan Equipment Schedule CiLY of Tukwila Equip. ID Equip Type Brand Name' Model No.' CFM BUILDING DIVISION Flow Controls Loca ' it SP' HP /BHP CITY I 'SEP 1 f I 17 2012 PERMIT CENT 'If available. 2 As tested according to Table 14 -1A through 14-1G. 3 If required. 4 COP HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. M12 -113 LVVJ VV clio■ lylvll Slaw 1.I lclyy vvuc 1 vI1110 Ivl IIVI 11 c0IUGI ILIQI OI IU IVIUILIIGI 1 Illy 11GAIUel IUG1I Mechanical Summary (back) MECH -SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 System Description See Section 1421 for full description of Simple System qualifications. All Systems: 1,0 No humidification? [No Reheat? If Heating /Cooling or Cooling Only: 54 Constant vol? ❑ Split system? IQ <= 84,000 Btuh? ❑ Economizer tg Air cooled? ❑ Packaged sys? ❑ <= 135,000 Btuh? EJ Cooling Cap < =15 Btuh /ft2? ❑ Heating,Cap. > 0 & < =10 Btuh /ft2? If Heating Only: ❑ <1000 cfm? ❑ <30% outside air? ❑ Heating Cap. <= 1413'tuh /ft?? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ap < =15 Heat/Cool Eq. with Cap < =10 Heating Only ( Reference Section 1421 alifies Economizer Exception tion 1 :Simple:System Allowed ('section 1420) Use Complex Systems (section 1430) Complex Systems Refer to MECH -COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential MECH -ECO Revised February 2011 Economizer Summary Check box(es) for exceptions being claimed. List the system /equipment that qualifies for each exception. See Section 1433 for full description of Economizer requirements. ❑ Full Air Econo: Ex 1: ❑ Ex 5: ❑ Ex 9a: ❑ Ex 2: ❑ Ex 6: ❑ Ex 9b: ❑ Ex 3: ❑ Ex 7: `� Ex 9c: add/ � � d ❑ Ex 4: ❑ ❑ Ex 10: rleJ'l1�'p/N't(i Decision Flowchart CA O. Use this flowchart to determine if project complies with Economizer requirements. If not, the Systems Analysis Option must be used. ( START Yes Reference Section 1433 Yes Full Air Economizer - Complies ified Un m Table 14 -1A, :, / EER 15% ode Yes ception it Cap <54,000 B it not Exterior 'ace No xception . it Cap < 33,000 Bt nit not Exterior o djacen Idg. Cap. w/o economizer <72,000 Btuh or 5 %? Exception 2: Chilled Water Sys. ' er 25% over Yes ptio er Cooled Re . aterside Economize ing chiiled b Sys No 141 0 Exception 4: Cooling 75% Site HR or Solar Exception 5: Special OA iltration Need ception Dehumidification with supporting rgy anal Exception 7: Heat Pump Loop eting All Crit- ception 9: Dedicated Server or Eq Rm ception 10: RF System Meeting All Criteria No Does Not Comply I Qualifies for Full Air Economizer Exception - Complies 0 ,�J�'vJ 1 LA �,q • G, r \\ City of Tukwila 1908 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director September 18, 2012 Andrea VanBlaricom McKinstry Company 5005 Third Av S Seattle, WA 98134 RE: Incomplete Letter #1 Mechanical Permit Application M12 -143 Verizon Wireless —132 Southcenter Mall Dear Ms. VanBlaricom, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on September 17, 2012 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 204 - 433 -7163 if you have any questions concerning the attached comments. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431 -3670. Sincerely Bill Rambo Permit Technician Enclosures File: M12 -143 W:\Permit Center \Incomplete Letters\2012\M12 -143 Incomplete Ltr #1.doc 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 - 431 -3670 • Fax: 206 - 431 -3665 Tukwila Building Division Allen Johannessen, Plan Examiner Determination of Completeness Memo Date: September 18, 2012 Project Name: Verizon Wireless Permit #: M12 -143 Plan Review: Allen Johannessen, Plans Examiner The Building Division has deemed the subject permit application incomplete. To assist the applicant in expediting the Department plan review process, please forward the following comments. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size). (If applicable) Structural Drawings and structural calculations sheets shall be original signed wet stamped, not copied.) 1. Provide a detail to show how the air - conditioning unit shall be seismically secured at the ceiling from the structure above. The unit shall not hang from the suspended ceiling grid system. 2. Show specifically where the condensate line shall drain to an approved location. Should there be questions concerning the above requirements, contact the Building Division at 206 -431- 3670. No further comments at this time. • PER CO D COSY • PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -143 DATE: 10 -03 -12 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 132 SOUTHCENTER MALL Original Plan Submittal Response to Correction Letter # X Response to Incomplete Letter # 1 Revision # After Permit Issued DEPARTMENTS: iL B i ing ivision Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10 -04 -12 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11 -01 -12 Approved ❑ Approved with Conditions V Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use On!y CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2 -28 -02 *PERMIT COORD CORD PLAN REVIEW /ROUTING SLIP ACTIVITY NUMBER: M12 -143 DATE: 09/14/12 PROJECT NAME: VERIZON WIRELESS SITE ADDRESS: 132 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division ASA Jt 4- 412 -/:� Fire Prevention Planning Division Public Works ❑ Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete ❑ DUE DATE: 09/18/12 Incomplete Not Applicable ❑ Comments: PermlI Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg' Fire ❑ Ping ❑ PW ❑ 'Staff Initials: TUES /THURS ROUTING: Please Route ❑ Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10/16/12 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use OnIy CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 1 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206 - 431 -3670 Fax: 206 - 431 -3665 Web site: http: / /www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: M12— 143 • Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Verizon Wireless Project Address: 132 Southcenter Mall Contact Person: 1-0.11 V ri lb,K ► anyiZhone Number: 2& Summary of Revision: ',VSm sO*cuyvp TAO. nb SV6 �1\ -. • LI Ai(Th- Cm OF TUKWILA Sheet Number(s): "Cloud" or highlight all areas of revision including date of re ision Received at the City of Tukwila Permit Center by: RY\ Entered in Permits Plus on OCT 03 2012 PGRIArr CENTER \applications \forms- applications on line\revision submittal Created: 8 -13 -2004 Revised: Contractors or Tradespeople P j�ter Friendly Page • General /Specialty Contractor A business registered as a construction contractor with L &1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MCKINSTRY CO LLC UBI No. 602569922 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINCL942DW Suite /Apt. License Type Construction Contractor City Seattle Effective Date 3/16/2006 State WA Expiration Date 3/16/2014 Zip 98134 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JLLYDIG+ MCKINSTRY LLC Construction Contractor General Unused 4/13/2010 4/13/2014 Active WESTVI'121RF WESTVENT INC Construction Contractor General Unused 12/6/1988 9/1/1994 Archived MCKIN* 372ND MCKINSTRY CO Construction Contractor General Unused 8/20/1963 1/2/2008 Re Licensed Business Owner Information Name Role Effective Date Expiration Date PEDERSEN, JAMIE D Agent 03/16/2006 Bond Amount ALLEN, DEAN CHARLES Partner /Member 03/16/2006 929519469 MOORE, DOUGLAS JAMES Partner /Member 03/16/2006 ALLEN, DAVID EDWARD Partner /Member 03/16/2006 WESTERN SURETY CO TEPLICKY, JOSEPH WILLIAM Partner /Member 03/16/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Western Surety Co 929519469 03/01/2011 Until Cancelled 01/23/2012 $12,000.00 02/24 /2011 2 WESTERN SURETY CO 929511574 09/09/2010 Until Cancelled $12,000.0009/02 /2010 1 TRAVELERS CAS & SURETY CO 104702039 01/03/2006 Until Cancelled 03/01 /2011 $12,000.0003/16 /2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 5 Zurich American Ins Co GLA-3999903 01/31/2012 01/31/2013 $2,000,000.00 12/16/2011 4 ZURICH AMERICAN INS CO GLA3999903 01/31/2011 01/31/2012 $2,000,000.00 12/20/2010 3 ZURICH AMERICAN INS CO CP0399990301 01/31/2009. 01/31/2011 $2,000,000.00 12/07/2009 2 ZURICH AMERICAN INS CO CP03999903 01/31/2008 01/31/2009 $2,000,000.00 01/31/2008 https://fortress.wa.gov/lni/bbip/Print.aspx 10/16/2012