HomeMy WebLinkAboutPermit D10-031 - SEGMENT 6 PLANS - RAISBECK AVIATION HIGH SCHOOL - BUILDING AND MECHANICAL PENTHOUSE1 1,
•
LIST OF ABBREVIATIONS
HIGHLINE SCHOOL DISTRICT 401
A
AB
ABV
NC
ACC-"
ACOUS
ACP
ACT
AD
ADD
ADDL
ADJ
AFF
AGG
AHU
AUALUM
ALT
ANOD
AHD
AP
APPROX
APPS
APT
ARCH
ASPH
AUX
AVE
AV/AVG
AWP
BOC
BD
BF
BF
BFD
BITUM
BL
BLDG
BLKG
BLVD
BLW
BM
BOT/BTM
BRG
BSMT
BTU
BTWN
BUR
BOW
C
CAB
CAP
CPT
CB
CBB
CD
CEM
CEM PL
CER
CFS
CG or C/G
CH
CHRL
CI
CIP
CJ
CL
CLG
CLK
CLKG
CLO
CLR
CLSR
CMU
CMP
CO
COL
COMP
CONC
COND
CONF
CONN
CONST
CONT
COOR
CORR
CPP
C/S
CR
CT
CTR
CTSK
CU
CW
CWP
D
d
db
D
DBL
DECID
DEPT
DET
DF
DIA
DIAG
DIFF
DIM
DISP
DL
DN
DR
DS
DTL
DW
DWG
DWR
N '
0
M
4
Anchor Bolt
Above
Asphalt Concrete
Accessible
Acoustical
Acoustical Ceiling Panel
Acoustical Ceiling Tile
Area Drain
Addendum
Additional
Adjustable
Above Finished Floor
Aggregate
Air Handling Unit
Aluminum
Alternate
Anodized
Automatic Hand Dryer
Access Panel
Approximate
Aluminum Plate Panel System
Apartment
Architectural
Asphalt
Auxiliary
Avenue
Average
Acoustic Wall Panel
Bottom of Curb
Board
Board Foot
Brace Frame
Bi -Fold Door
Bituminous
Building Line
Building
Blocking
Boulevard
Below
Bench Mark
Bottom
Bearing
Basement
British Thermal Unit
Between
Built -Up Roof
Bottom of Wall
Celsius
Cabinet
Capacity
Carpet
Catch Basin
Cementitious Backer Board
Ceiling Diffuser
Cement
Cement Plaster
Ceramic
Cubic Feet per Second
Comer Guard
Coat Hook
Chair Rail
Cast Iron
Cast In Place
Control Joint (Saw Cut)
Center Line
Codling
Clock.
Caulking
Closet
Clear, Clearance
Closer
Concrete Masonry Units
Corrugated Metal Pipe
Clean Out
Column
Composite
Concrete
Condition
Conference
Connection
Construction
Continuous
Coordinate
Corridor
Corrugated Polyentylen: Pipe
Clock/Speaker
Cold Rolled
Ceramic Tile
Center
Countersunk
Cubic
Cold Water
Composite Wall Panel
penny (nails)
decibel
Depth
Double
Deciduous
Department
Detail
Drinking Fountain
Diameter
Diagonal
Diffuser
Dimension
Disposal
Dead Load
Down
Door/ Drain
Downspout
Detail
Dishwasher
Drawing
Drawer
E
Ee
EA
EB
EF
EG
EJ
ELEV
ELL
ELEC
ELEV
ENAM
ENTR
EP
EQ
EQJ
EQUIP
ESS
ETR
EWC
EXC
EXH
EXP
(E)/EXIST
EXT
F
F
FA
FAAP
FACP
FB
FBD
FD
FDC
FDN
FE
FEC
FF
FFE
FG
FH
FHC
FHMS
FHSMS
FHWS
FIC
FIN
FIO
FIT
FL
FLASH.
FLUOR
FM
FO
FOB
FOC
FOF
FOIC
FTIC
FOIV
FOM
FOS
FP
FR
FRP
FRT
FS
FT
FTG
FURN
FURR
FUT
FVC
FWP
FWSS
G
GA
GALV
GB
GBB
GC
GD
GFI
GFRC
GFRG
GFRP
GIP
GL
GLAM
GLB
GLC
GND
GSM
GWB
GYP
H
H
HB
HC
HCT
HCW
HDBD
HDNR
HDPE
HDR
HDO
HDWD
HDWR
HM
HORIZ
HP
HR
HS
HSS
HT
HTG
HW
HWH
HWR
HWS
East
Each
Expansion Bolt
Exhaust Fan
Exhaust Grille
Expansion Joint
Elevation
English Leaming Lab
Electrical
Elevator
Enamel
Entrance
Electrical Panelboard
Equal
Earth Quake Joint
Equipment
Expanded Stainless Steel Panel
Existing To Remain
Electric Water Cooler
Excavation
Exhaust
Expansion
Existing
Exterior
Fahrenheit
Fire Alarm
Fire Alarm Annunciator Panel
Fire Alarm Control Panel
Flat Bar
Fiber Board
Floor Drain
Fire Department Connection
Foundation
Fire Extinguisher
Fire Extinguisher Cabinet
Finish Floor
Finish Floor Elevation
Float Glass
Fire Hydrant
Fire Hose Cabinet
Flat Head Machine Screw
Flat Head Sheet Metal Screw
Flat Head Wood Screw
Fum and Installed by Contractor
Finish
Fum. and Installed by Owner
Fum. and Installed by Tenant
Floor
Flashing
Fluorescent
From
Face Of
Face Of Brick
Face Of Concrete
Face Of Finish
Fum. by Owner Installed by GC
Fum. by Tenant Installed by GC
Fum. by Owner Installed by Vendor
Face of Masonry
Face of Studs
Fire Proof(ing)
Fire Resistive
Fiber Reinforced Plastic Panels
Fire Treated
Floor Sink
Foot or Feet
Footing
Furniture
Furring
Future
Fire Valve Cabinet
Flat Wall Paint
Fabric Wall System Structure
Gas
Gauge
Galvanized
Grab Bar
Gypsum Backer Board
General Contractor
Garbage Disposal
Ground Fault Interrupter
Glass Fiber Reinforced Concrete
Glass Fiber Reinforced Gypsum
Glass Fiber Reinforced Plaster
Galvanized Iron Pipe
Glazing
Glue Laminated Wood
Glue Laminated Beam
Glue Laminated Column
Ground
Galvanized Sheet Metal
Gypsum Board
Gypsum
High
Hose Bib
Hollow Core
Hollow Clay Tile
Hollow Core Wood
Hardboard
Hardener
High Density Polyethylene
Header
High Density Overlay
Hardwood
Hardware
Hollow Metal.
Horizontal
Heat Pump
Handrail
Hook Strip
Hollow Steel Section
Height
Heating
Hot Water
Hot Water Heater
Hot Water Retum
Hot Water Supply
GRAPHIC LEGEND
SYMBOL LEGEND
A3.01
3
A4.01
3
A4.01
1
BUILDING ELEVATION
-VIEW NUMBER
-SHEET NUMBER
BUILDING SECTION
-VIEW NUMBER
-SHEET NUMBER
WALL SECTION
-VIEW NUMBER
-SHEET NUMBER
DETAIL REFERENCE
-VIEW NUMBER
1
i
A40
-SHEET NUMBER
DETAIL REFERENCE
OR -
ENLARGED PLAN CALLOUT
-VIEW NUMBER
-SHEET NUMBER
INTERIOR ELEVATION
-VIEW NUMBER
-SHEET NUMBER
GRID L:NES
PARTITION TAG
-PARTITION TYPE
ROOF & FLOOR TAG
ROOF OR FLOOR TYPE
D
E
MP
N
ND
NFO
NSP
NST
NSUL
NT
J
JAN
JST
JT
K
K
KD
KIP
KIT/
KITCH
KO
KP
KS
L
L.
LAB
LAM
LAV
LB
LC
LF
LH
LHR
LKR
LL
LP
LSG
LT
LTWT
M
MACH
MAINT
MAS
MAT
MAX
MB
MC
MCW
MDF
MDF
MDO
MECH
MEMB
MTL/MET
MEZZ
MFR
MG
MH
MIN
MIR
MISC
MO
MOD
MPU
MRS
MRSS
MS
M/S
MTD
MTL
MUL
MUTCD
MW
N
N
NA or N/A
NC
NIC
NOJ#
NOM
NTS
0
OA
OC
OCC
OD
OFD
OFF
OH
OHWS
OPNG
OPP
OSB
OZ
P
PA
PB
PBB
PBD
PC
PCD
PDF
PERF
PERP
PG
PH
PL
PLAIN
PLAS
PLY
PLYWD
PNL
PNT
POL
nside Diameter
nvert Elevation
nsulated Metal Panel
nches
ndicated
nformation
nspection
nstallation
nsulation
nterior
Janitor
Joist
Joint
Kip(s)
Kiln Dried
1000 pounds
Kitchen
Knock Out
Kick Plate
Knee Space
Length
Laboratory
Laminated
Lavatory
Pound
Learning Community
Linear Foot
Left Hand
Left Hand Reverse
Locker
Live Load
Low Point
Laminated Safety Glass
Light
Light Weight
9 9
Machine
Maintenance
Masonry
Material
Maximum
Marker Board
Medicine Cabinet
Mineral Core Wood
Medium Density Fiberboard
Main Data Frame
Medium Density Overlay
Mechanical
Membrane
Metal
Mezzanine
Manufacturer
Mirror Glass
Manhole
Minimum/ Minute
Mirror
Miscellaneous
Masonry Opening
Modify
Multi Purpose Unit
Motorized Roller Shade
• Motorized Roller Skylight Shade
Metal Siding
Mirror with Shelf
Mounted
Metal
Mullion
Manual on Uniform Traffic Ctrl Devices
Microwave
North
Not Applicable
Non -Corroding
Not In Contract
Number
Nominal
Not To Scale
Overall
On Center
Occupancy
Outside Diameter
Overflow Drain
Office -
Over Head
Oval Head Wood Screw
Opening
Opposite
Oriented Strand Board
Ounce
Paint
Public Address
Pegboard
Plaster Base Board
Particle Board
Precast
Paper Cup Dispenser
Power Driven Fastner
Perforated
Perpendicular
Plate Glass
Phase
Plate
Plastic Laminate
Plaster
Plywood
Plywood
Panel
Paint
Polish
WINDOW TAG
W = WINDOWS
C = CURTAIN WALL
S = STOREFRONT
L = LOUVERS
NORTH ARROW
DIM POINT
LEVEL LINE
SPOT ELEVATION
10'-0"AFF
CUT LINE
REVISION CLOUD
REVISION NUMBER
f. ROOM TAG ,
CIA&+ROOM ROOM NAME
-)ZOOM NUMBER
2200.-
'71
200;J
A\
DEFERRED SUBMITTALS
PP
PRE FAB
PREP
PSF
PSI
PT
PTD
PTDW
PTN
PVC
PVMT
Q
QT
QTR
R
R
R&S
RA
RAD
RB.
RCP
RD
REBAR
RECEP
RECEPT
RECT
REF
REG
REINF
REQD
REQ'D
RES
RET
REV
RH
RM
RO
ROW
RP
RRL
RS
RWL
S
S&R
S&V
SAFM
SAN
SBS
SC
Push Plate
Prefabricate
Prepare/Peparation
Pound Per Square Foot
Pounds per Square Inch
Preservative Treated
Paper Towel Dispenser
PTD & Waste Receptacle
Partition
Polyvinyl Chloride
Pavement
Quarry Tile
Quarter
Radius
Backer Rod and Sealant
Return Air
Radius
Rubber Base
Reflected Ceiling Plan
Roof Drain
Reinforcing Bar
Reception
Receptacle
Rectangular
Refrigerator
Register
Reinforced
Required
Required
Resilient
Retaining/ Retum
Revision
Round Head
Room
Rough Opening
Right Of Way
Radius Point
Rub Rail
Rough Sawn
Rain Water Leader
South
Shelf and Rod
Stain & Varnish
Self Adhering Flashing Membrane
Sanitary
Styrene Butadiene Styrene
Solid Core
SCWSCHED Schedule
SCR
SCW
SD
SDR
SEC
SECT
SF
SFC
SFWS
SGEN
SHR
SHT
SHTG
SHV
SIM
SLR
SM
SMR
SMS
SND
SNW
SPEC
SQ
SS
SST
ST
STA
STC
STD
STL
STOR
STRUCT
SUBFL
SURF
SUSP
SYM
T
T
T&B
T&G
TB
TBB
TSCD
TOC
TD
TEL
TEMP
TER
TF
TG
THK
THR
TMV
TN
TO
TOD
TOF-
TLT
TOL
TOP
TOS
TOW
TPD
TV
TWS
TYP
Shower Curtain Rod
Solid Core Wood
Soap Dispenser
Standard Dimension Ratio
Second
Section
Square Feet
Special Floor Coating
Stretched Fabric Wall System
Semi Gloss Enamel
Shower
Sheet
Sheathing
Sheet Vinyl
Similar
Sealer
Sheet Metal
Sheet Metal Raceway
Sheet Metal Screws
Sanitary Napkin Dispenser
Sanitary Napkin Waste Receptacle
Specification
Square
Service Sink
Stainless Steel
Stone
Station
Sound Transmission Class
Standard
Steel
Storage
Structure/ Structural
Sub floor
Surface
Suspended
Symmetrical
Top/Tile
Top & Bottom
Tongue & Groove
Tack Board
Tile Backer Board
To'iet Seat Cover Dispenser
Top of Concrete
Towel Dispenser & Waste
Tetephone
Temporary
Terrazzo
Tap of Footing
Tempered Glass
Thick
Threshold
Thermostatic Mixing Valve
Toe Nail
Top Of
Top of Deck
Top of Framing
Toilet
Toierance
Top of Plate
Top of Steel
Top of Wall
Toilet Paper Dispenser
Television
Tackable Wall Surface
Typical
U
UC
UL
UNFIN
UNO
UON.
UR
UTIL
UV
V
V
VAR
VCT
VERT
VEST
VG
VOL
VP
VRP
VWC
W
W
W/0
W/
WAIN
WB
WBFS
WC
WD
WDW
WF
WG
WH
WOM
WP
WR
WS
WT
WWF
WWM
Y
YD
Under Counter
Underwriters Laboratories
Unfinished
Unless Noted Otherwise
Unless Otherwise Noted
Urinal
Utility
Ultra Violet
Valve
Vamish
Vinyl Composition Tile
Vertical
Vestibule
Vertical Grain
Volume
Veneer Plaster
Vitrulan Reinforced Polyurethane
Vinyl Wall Covering
West
Without
With
Wainscot
White Board
Water Bottle Filling Station
Wag Covering
Wood
Window
Wide Flange
Wire Gauge
Water Heater
Walk Off Matt
Waterproof
Waste Receptacle
Weatherstripping
Weight
Welded Wire Fabric
Welded Wire Mesh
Yard Drain
SUPPLEMENTAL ABBREVIATIONS
SYMBOLS USED
AS ABBREVIATIONS
&
Q
d
R
0
O
And
Angle
At
Centerline
Channel
Number
Penny
Per
Property Line/ Plate
Plus or Minus
Round/Diameter
Square/ Square Feet
Degree(s)
Delta/Change
ABBREVIATED STRUCTURAL SHAPES
C American Standard Channel
HP HP Shape
L Angle
M M Shapes
MC Miscellaneous Channel
MT Structural Tee Cut from M Shape
PL Plate
S S Shapes
ST Structural Tee Cut from S Shape
ST Structural Tubing
TS Tube Steel
W W Shapes
WT Structural Tee Cut from W Shape
ABBREVIATED TOILET ACCESSORIES
AHD
BCS
CH
FSS
GB
HSD
MIR
PCD
PTD
PTDW
RH
SCR
SD
SND
SNW
TB
TPD
TSCD
WR
Automatic Hand Dryer
Baby Chaging Station
Coat Hook
Folding Shower Seat
Grab Bar
Hand Sanitizer Dispenser
Mirror
Paper Cup Dispenser
Paper Towel Dispenser
Paper Towel Dispenser & Waste Receptacle
Robe Hook
Shower Curtain Rod
Soap Dispenser
Sanitary Napkin Dispenser
Sanitary Napkin Waste Receptacle
Towel Bar
Toilet Paper Dispenser
Toilet Seat Cover Dispenser
Waste Receptacle
HATCH LEGEND (CUT MATERIAL)
iffj
'f , f" •/
EARTH
GRAVEL
CONCRETE
CMU
METAL
PLYWOOD
MDF
FINISH WOOD
KMBATT INSULATION
Err,
1
RIGID INSULATION
SIMI-RIGID INSULATION
• GWB
TYPICAL DOOR SWINGS
1001
1000
R1000
L
TYPICAL DOOR - 90 DEGREE DOOR SWING
- OPENING NUMBER
180 DEGREE DOOR SWING
- OPENING NUMBER
RELITE
- OPENING NU
BER
OVERHEAD COILING DOOR
- '" JGNUMBER
GENERAL CONTRACTOR TO PROVIDE REVIEWED/STAMPED SUBMITTAL FOR THE 11 -EMS
OF TUKWILA: LISTED BELOW TO THE CITY
1. EXTERIOR CLADDING
2. CASTELLATED FLOOR BEAMS
•
®' (iiirminuregi
111.M111111111=.
aym"°`F`aii° III 11111
g.��M■
n
II
vau i IIIc
u II
I
IIII.=1111111MII.
.
'moi UI IIIII����
ezum m. IIII.M=11111M.
gni
1���
nc
I�
;III____
lilt IIIII���
u III I IiII.��U
�.
4.,III IIIIIII11I•��_•
VICINITY MAP
•-__--------------MEMIIII=MIIIMMIIIIIIIIMISIIIIMIIMIIIIMIIINIMME It __
■- RA"IBEG4�
num I■------•
I
------- it
Nows
min
II■-- AVIAT!�0
nom imminommuni.
mom
.ENE
mmin
mom
.mss
iiimiliird-iiirMilmemommin-
imoommumummmimonsinimif
.=M�E=ssssssss.■ .4.,.
INN MNINM1=ssss=OM .ss.
Ii�w W�ssssd
ri. ��
�I,.HII�G�H11 S C H2O O
IL1l�� .
r
I s.
IAIVIIIAtTII O1N IHII G1NFCilh
KING CO.
INT'L.
AIRPORT
RAISBECK AVIATION
HIGH SCHOOL SITE
PUBLIC HEALTH NOTE
DO NOT USE IMAGE FOR CONS ' UCTION
PROJECT DATA
■
PROJECT ADDRESS:
RAISBECK AVIATION HIGH SCHO
9229 EAST MARGINAL WAY S.
TUKWILA, WA 98108
OWNER: HIGHUNE SCHOOL DISTRICT # 401
SCOPE OF WORK:
JURISDICTION:
FIRE:
WATER AND SEWER:
POWER:
ZONING:
OCCUPANCY:
TYPE OF CONSTRUCTION:
LOT SIZE:
TAX I.D. NOJASSESSORS
PARCEL NO.:
LEGAL DESCRIPTION:
NEW CONSTRUCTION OF A +/- 86,000 F, 3 -STORY
HIGH SCHOOL BUILDING AND MECHA ICAL
PENTHOUSE.
CITY OF TUKWILA
TUKWILA FIRE DEPARTMENT
CITY OF TUKWILA
SEATTLE CITY LIGHT
MIC/H
GROUP E
TYPE I -B
281,605 S.F. OR 6.46 ACRES
542260002002
LOT 2, CITY OF TUKWILA SHORT PLAT NO. L05-057, RECORDED FE
UNDER RECORDING # 20070228900007 IN KING COUNTY, WASHING
(SEE TOPOGRAPHIC SURVEY; THIS SET)
GROSS BUILDING SQUARE FOOTAGE:
LEVEL 1:
LEVEL 2:
LEVEL 3:
MECHANICAL PENTHOUSE:
EXTERIOR TERRACES:
21,005 SF
25,033 SF
26,283 SF
12,726 SF
1,310 SF
TOTAL: 86,357 SF
VARY 28, 2007
N STATE.
PUBLIC HEALTH - SEATTLE & KING COUNTY INSPECTION REQUIRED ON COMPLETION OF WORK PRIOR TO OPENING.
GENERAL NOTES
1. PROJECT MANUAL THAT COMPLIMENTS THIS DRAWING SET IS WRITTEN IN MASTER FORMAT 2004 EDITION. PLEA' E REVIEW
PRIOR TO BID.
2. VERIFY AND COORDINATE SITE CONDITIONS AND DIMENSIONS. BRING INCONSISTENCIES TO ATTENTION OF ARCHITECT BEFORE PROCEEDING WITH WORK.
3. IMMEDIATELY BRING INCONSISTENCIES, ERRORS AND OMISSIONS FOUND IN THE DRAWINGS AND SPECIFICATIONS TO ATTENTION OF ARCHITECT.
4. DO NOT SCALE DRAWINGS. COORDINATE DIMENSIONS SHOWN ON DRAWINGS WITH ACTUAL FIELD MEASUREMENTS. NOTIFY ARCHITECT OF DISCREPANCIES.
5. ALL DIMENSIONS AT NEW CONSTRUCTION ARE TO FACE OF FRAMING, FACE OF CONCRETE AND NOMINAL FACE OF MASONRY, CENTERLINE OF OPENINGS, AND
CENTERLINE OF FRAMING AND COLUMNS, UNLESS NOTED OTHERWISE.
6. WORK INSTALLED IN CONFLICT WITH CONSTRUCTION DOCUMENTS WILL BE CONSIDERED IN NON-CONFORMANCE AND SHALL BE CORRECTED AT NO EXPENSE TO
OWNER OR ARCHITECT.
7. COORDINATION: COORDINATE WORK TO COMPLY WITH DRAWINGS AND SPECIFICATIONS, INCLUDING MECHANICAL, ELECTRICAL, EQUIPMENT AND OTHER
CONSTRUCTION.
8. FOLLOW MANUFACTURER'S INSTRUCTIONS, EXCEPT WHERE MORE STRINGENT REQUIREMENTS ARE INDICATED OR REQUIRED BY CONSTRUCTION DOCUMEN S OR
APPLICABLE CODES, ORDINANCES AND REGULATIONS.
9. PROVIDE AND INSTALL SOLID BLOCKING OR BACKING FOR ALL WALL AND CEILING MOUNTED ITEMS.
10. PROVIDE INTERMEDIATE ROD AND SHELF SUPPORTS FOR SPANS EXCEEDING 36".
11. INSTALL OUTLETS, SWITCHES AND OTHER RECESSED ITEMS AT FIRE RATED WALLS IN ACCORDANCE WITH I.B.C.
12. ISOLATE AND OFFSET PENETRATION ONE STUD SPACE MINIMUM AT SOUND RATED WALLS TO PREVENT SOUND TRANSMISSION.
13. INSTALL GYPSUM BOARD, OR OTHER SHEATHING OR BACKER BOARD AS SCHEDULED OR INDICATED, ON BOTH SIDES OF WALL FRAMING UNINTERRUPTED FROM
FLOOR TO UNDERSIDE OF FLOOR OR ROOF DECK, UNLESS NOTED OTHERWISE.
14. ATTACH PIPING IN SOUND RATED WALLS WITH VIBRATION ISOLATORS. ISOLATE PIPIN TO PREVENT CONTACT WITH ADJACENT CONSTRUCTION.
15. MOUNT ELECTRICAL WIRING DEVICES AND MECHANICAL TEMPERATURE SENSORS AT kiEIGHTS PER SPECIFICATIONS AND INTERIOR ELEVATIONS. VERIFY SWI H,
OUTLET AND OTHER DEVICE HEIGHTS TO CLEAR CASEWORK, RADIATORS AND WALL MOUNTED ITEMS, INCLUDING BACK SPLASHES.
16. COORDINATE SIZES AND LOCATIONS OF OPENINGS AND ROUGH -INS FOR MECHANICAL', ELECTRICAL AND OTHER EQUIPMENT WITH RELATED SUB-CONTRAC.ORS, AND
SHOP DRAWINGS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK.
17. VERIFY SIZES AND LOCATIONS OF MECHANICAL AND ELECTRICAL EQUIPMENT PADS, CURBS, BASES, POWER, WATER AND DRAIN INSTALLATION WITH EQUI MENT
MANUFACTURERS BEFORE PROCEEDING WITH THE WORK. PROVIDE AND INSTALL SEISMIC BRACING & FASTENING IN ACCORDANCE WITH CODE REQUIREMEN S.
18. COORDINATE EXACT LOCATION OF CONDUIT, PLUMBING AND PIPING WITH ELECTRICAL\AND MECHANICAL SUBCONTRACTORS.
19. EXIT DOORS: OPERABLE FROM INSIDE BUILDING WITHOUT USE OF KEY OR SPECIAL KNOWLEDGE OR EFFORT.
20. EXIT SIGN LETTERS: SIX (6) INCHES HIGH MINUMUM. CONFORM WITH APPLICABLE CODES.
21. FINISHES: IN FINISHED INTERIOR AREAS: NO EXPOSED PIPE, CONDUITS, DUCTS, VENTS, ETC. U.N.O., CONCEAL UTILITY LINES BEHIND FINISHED CONSTRUCT! N
UNLESS NOTED AS EXPOSED CONSTRUCTION ON DRAWINGS OR APPROVED BY ARCHITECT. IF A FOREMENTIONED WORK CANNOT BE CONCEALED WITHIN FINIS ED
CONSTRUCTION OF THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL PROVIDE & INSTALL FURRED & FINISHED HORIZONTAL & VERTICAL CHASES TO MATC
ADJACENT FINISH TO CONCEAL WORK, COORDINATE WITH ARCHITECT. s 1.
22. OFFSET AND ADJUST FRAMING TO MAKE FINISHED SURFACES FLUSH AND TRUE TO LINE. 1
23. PROVIDE GALVANIC ISOLATION BETWEEN DISSIMILAR METALS.
24. FIRE EXTINGUISHER CABINETS, EXIT SIGNS, FIRE ALARM AND FIRE PROTECTION SYST M COMPONENTS SHALL BE LOCATED IN CONFORMANCE WITH CITY OF TU ILA
FIRE DEPARTMENT AND OTHER REGULATORY REQUIREMENTS.
25. PROVIDE AND INSTALL FIRE -RESISTIVE JOINT SYSTEMS, FIRE BLOCKS, DRAFT STOPS, AND FIRESTOP SYSTEMS IN ACCORDANCE WITH I.B.C.
26. FIRE PROTECTION: PROVIDE AUTOMATIC FIRE SUPPRESSION SPRINKLER SYSTEM THROUGHOUT, IN ACCORDANCE WITH APPLICABLE CODES, REGULATIONS, AND
ORDINANCES. SEE REFLECTED CEILING PLANS AND FIRE PROTECTION DRAWINGS.
27. SPRINKLER SYSTEM TO BE APPROVED BY CITY OF TUKWILA FIRE DEPARTMENT AND OTHER REGULATORY AGENCIES PRIOR TO INSTALLATION. OBTAIN ARCHITECT'S
APPROVAL OF FIRE PROTECTION DRAWINGS PRIOR TO SUBMITTAL FOR FIRE DEPARTMENT REVIEW.
28. RUN FIRE PROTECTION MAIN LINES AND INSPECTOR TEST LINES OUT BEYOND BUILDING LINES. DO NOT DRAIN WATER ACROSS SIDEWALK OR OTHER CONCRETE
is. PRAOVIDE DESIGN BUILD FIRE PROTECTION DRAWINGS AND ENGINEERING AS REQUIRED BY CONSTRUCTION DOCUMENTS AND THE CITY OF TUKWILA FIRE
DEPARTMENT.
30. COORDINATE INSTALLATION OF FIRE,PROTECTION SYSTEM WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL AND OTHER WORK TO
ENSURE NO CONFLICT AS A RESULT OF FIRE PROTECTION SYSTEM INSTALLATION.
31. REFER TO SHEET G1.02 FOR LIMITS OF FIREPROOFING FOR THIS PROJECT. FIREPROOFING MAY BE OMITTED IN CERTAIN DRAWINGS AND DETAILS FOR CLARITY.
32. CORNER GUARD LOCATIONS ARE SHOWN ON FINISH / SIGNAGE PLANS.
SPECIAL INSPECTIONS
1. REQUIRED BY THE FIRE DEPARTMENT:
-OVERHEAD SPRINKLER PIPING
-FIRE ALARM
-HOOD AND DUCT INSPECTIONS
-FIRE DOORS AND FIRE DAMPERS
-FIRE FINAL
2. AS SPECIFIED IN IBC SECTION 1704 AND 1705:
-SEE STATEMENT OF SPECIAL INSPECTIONS TABLE ON STRUCTURAL SHEET S1.03
SHEET IND X
G0.01 1 COVER SHEET
i G1.01 1 CODE ANALYSIS PLANS & NOTES
• 1G1.02 LIMITS & TYPES OF FIREPROOFING
G1.03 !LIMITS & TYPES OF FIREPROOFING
!TOPOGRAPHIC SURVEY
G4.00 !SITE PLAN
C1.01 NOTES, LEGEND, ABBREVIATIONS, AND INDEX
`02.01 DEMOLITION PLAN
lC3.01 TEMPORARY EROSION AND SEDIMENT CONTROL (T.E.S.C.) PLAN
103.02 !TEMPORARY EROSION AND SEDIMENT CONTROL (T.E.S.C.) DETAILS
;AND NOTES
C4.01 GRADING AND STORM DRAINAGE PLAN
C4.02 ; GRADING AND STORM DRAINAGE PLAN
! C4.03 1 FOUNDATION AND ROOF DRAINAGE PLAN
C4.04 FOUNDATION AND ROOF DRAINAGE PLAN
1C4.05 !DRAINAGE DETAILS
105.01 rHORIZONTAL CONTROL AND PAVING PLAN
05.02
;HORIZONTAL CONTROL AND PAVING PLAN
05.03
!PAVEMENT MARKINGS AND SIGNALS PLAN
[C5.04 I PAVING DETAILS
06.01 !UTILITY PLAN
106.02 UTILITY PLAN
C6.03 !UTILITY PROFILES
1L1.00
.LANDSCAPE SITE PLAN
1L1.10 LANDSCAPE MATERIALS PLAN - EAST
k
LI. I I
I1-ruliJJ. P\rc rvIt' I cr'II L. rLP11V - V CO I
LANDSCAPE GRADING PLAN - EAST
L2.10
L2.11
LANDSCAPE GRADING PLAN - WEST
L3.10
!LANDSCAPE SECTIONS AND ELEVATIONS
L3.20
LANDSCAPE DETAILS
L3.21
j LANDSCAPE DETAILS
L4.10
i IRRIGATION PLAN - EAST
L4.11
1 IRRIGATION PLAN - WEST
L5.10
!PLANTING PLAN - EAST
L5.11
!PLANTING PLAN - WEST
L5.20
PLANTING DETAILS & SCHEDULE
A1.11 COMPOSITE FLOOR PLANS - LEVEL 1 & 2
!A1.12 COMPOSITE FLOOR PLANS - LEVEL 3 & MECHANICAL PENTHOUSE
1A1.13 COMPOSITE ROOF PLAN
41/42.01 LEVEL 1 FLOOR PLAN
;A2.01D !LEVEL 1 FLOOR DIMENSION PLAN
A2.02 ! LEVEL 2 FLOOR PLAN
1A2.02D LEVEL 2 FLOOR DIMENSION PLAN j
A2.03 !LEVEL 3 FLOOR PLAN
1A2.03D ,LEVEL 3 FLOOR DIMENSION PLAN
A2.04 ! MECHANICAL PENTHOUSE PLAN
A2.05 (ROOF PLAN
A3.01 !EXTERIOR ELEVATIONS
A3.11 !ENLARGED EXTERIOR ELEVATIONS -
NORTH -- - -
A3 12
;A3.13
A3.14
A3.21
1A4.01
A4.02
A4.03 -
1 ENLARGED EXTERIOR ELEVATIONS -
ENLARGED EXTERIOR ELEVATIONS
SOUTH
- EAST & WEST
ENLARGED EXTERIOR ELEVATIONS 1BUILDING SECTION EAST/WEST
WALL SECTIONS
1 WALL SECTIONS
j WALL SECTIONS
A4.04
WALL SECTIONS
MECH PENTHOUSE SOUTH
1A4.05 ;WALL SECTIONS
A4.11 [SHAFT SECTIONS
IA4.12 !SHAFT SECTIONS
A4.13 !SHAFT SECTIONS
-A5.11 STOREFRONT AND LOUVER TYPES
A5.12 CURTAINWALL TYPES - -
A5.13 CURTAINWALL TYPES
A5.14 CURTAINWALLTYPES
;A5.21 ;STOREFRONT OPENING DETAILS
A5.23 I CURTAINWALL OPENING DETAILS
'A5.25 CURTAINWALL OPENING DETAILS
1A5.31 !EXTERIOR CLADDING DETAILS
'A5.32 ;EXTERIOR CLADDING DETAILS
A5.33 1 EXTERIOR CLADDING DETAILS
A5.41 ! MISC. EXTERIOR DETAILS
A5.81 !ROOF DETAILS
!A6.11 ENLARGED TOILET AND CUSTODIAN PLANS
}A6.21 !ENLARGED CENTRAL STAIR PLANS AND SECTIONS
!A6.22 ! ENLARGED EAST STAIR PLANS AND SECTIONS
;A6.23 ENLARGED WEST STAIR PLANS AND SECTIONS
A6.24 MECHANICAL PENTHOUSE STAIR PLANS AND SECTIONS
1A6.28 STAIR & RAILING DETAILS
A6.29 j STAIR & RAILING DETAILS
A6.31 ENLARGED ELEVATORS PLANS, SECTIONS AND DETAILS
1A6.41 ;TELESCOPING SEATING PLAN AND STRIPING PLAN
!A6.42 ;TELESCOPING SEATING PLAN & SECTION
A7.01 1 INTERIOR ELEV. LOBBY / CENTRAL STAIR
1A7.02 !INTERIOR ELEV. LEVEL 1
A7.03 ; INTERIOR ELEV.
LA7.04 !INTERIOR ELEV.
A7.05 I INTERIOR ELEV.
A7.06 ; INTERIOR ELEV.
A7.07 INTERIOR ELEV.
A7.08 '; INTERIOR ELEV.
LEVEL 1 - WEST CORRIDOR
LEVEL 1
MULTIPURPOSE ROOM
LEVEL 1 - EAST CORRIDOR
LEVEL 1
LEVEL 1
A7.09 1 INTERIOR ELEV.
A7.10 INTERIOR ELEV.
LEVEL 2
LEVEL 2
M/.I 1
' Intl CfCWR CLCV. LCVCLL ..
A7.12
INTERIOR ELEV. LEVEL 3
A7.13
INTERIOR ELEV. LEVEL 3 _ __
A7.14
INTERIOR ELEV. LEVEL 3
!A8.01
!LEVEL 1 - REFLECTED CEILING PLAN
A8.02
LEVEL 2 - REFLECTED CEILING PLAN
A8.03
LEVEL 3 - REFLECTED CEILING PLAN
i -A8.04
MECHANICAL PENTHOUSE - REFLECTED CEILING PLAN
!A9.01
WALL TYPE SCHEDULE
'A9.02
WALL TYPE SCHEDULE
A9.03
ROOF, CEILING & FLOOR TYPE SCHEDULE AND DETAILS
A9.31 DOOR AND HOLLOW METAL FRAME SCHEDULE AND TYPES
A9.51 INTERIOR DETAILS
iA9.71 CEILING DETAILS
;A10.11 INTERIOR FINISH SCHEDULE
A10.41 SIGNAGE DETAILS
REVISIONS
No changes shaft be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require new plan submitt fall
and may include additi Ian review fees..
FILE COPY
Permit No.
Plan review approval is subject to errors and ,I
Approval of construction documents does not authorize
the violation of any adopted code or ordinance. Receipt
of approved Field Copy and con es is acknowledged:
�c k owl /edged:
By nqacify. 1�l I\ 1 1L= er
�
t/
Date' -f c
City Of Tukwila
`1
BUILDING DIVISION
S1.01
!S1.02 !S1.02
S1.03
81.04
S2.01
IS2 01a
1 S2.01 b
S2.01c
'S2.02
S2.02a
S2.03
i S2.03a
52.04
S2.04a__
S2.05
I S2.11
GENERAL NOTES
GENERAL NOTES
GENERAL NOTES
GENERAL NOTES
LEVEL 1 PLAN
LEVEL 1 SLAB PLAN
LEVEL 1 FOUNDATION PLAN
; LEVEL 1 PILE PLAN
LEVEL 2 FRAMING PLAN
LEVEL 2 SLAB PLAN
LEVEL 3 FRAMING PLAN
LEVEL 3 SLAB PLAN
MECHANICAL PENTHOUSE FRAMING PLAN
MECHANICAL PENTHOUSE SLAB PLAN
ROOF FRAMING PLAN
NORTH ELEVATION
S2.12 • ': SOUTH ELEVATION
I S2.13 ' EAST/WEST ELEVATION
S3.01 FOUNDATION DETAILS
S3.02 ; FOUNDATION DE °AILS
rS3.03 FOUNDATION DETAILS
S3.04 I FOUNDATION DETAILS
i 53.11 FOUNDATION DETAILS
S4.01 ;FLOOR FRAMING DETAILS
S4.02 1 FLOOR FRAMING DETAILS
S4.03 FLOOR FRAMING DETAILS
T
S4.04 FLOOR FRAMING DETAILS
S4.05 FLOOR FRAMING DETAILS
S4.11 ! ROOF FRAMING DETAILS
S4.12 ROOF FRAMING DETAILS
S4.13 ROOF FRAMING DETAILS
S5.01 BRACED FRAME ELEVATIONS
S5.02 BRACED FRAME ELEVATIONS
S5.03 BRACED FRAME DETAILS
55.04 BRACED FRAME DETAILS
S5.05 BRACED FRAME DETAILS
S6.01 COLD FORMED STEEL FRAMING DETAILS
S6.02 I COLD FORMED STEEL FRAMING DETAILS
S6.03 COLD FORMED STEEL FRAMING DETAILS
S7.01 ENLARGED STAIR PLANS -
S7.02 STAIR FRAMING DETAILS
S7.03 STAIR FRAMING DETAILS
M0.01
1M0.02
1M0.03
1M0.04
M0.05
M1.00
!M1.01
M2.01 : LEVEL 1 PLUMBING FLOOR PLAN - -
M2.02 ! LEVEL 2 PLUMBING FLOOR PLAN
M2.03 LEVEL 3 PLUMBING FLOOR PLAN
M2.04 MECHANICAL PENTHOUSE PLUMBING FLOOR PLAN
M3.01 LEVEL 1 HVAC FLOOR PLAN
M3.02 LEVEL 2 HVAC FLOOR PLAN
; M3.03 LEVEL 3 HVAC FLOOR PLAN
M3.04 1 MECHANICAL PENTHOUSE LOWER HVAC FLOOR PLAN
_M3.05 MECHANICAL PENTHOUSE UPPER HVAC FLOOR PLAN
M4.01 LEVEL 1 HVAC PIPING FLOOR PLAN
M4.02 LEVEL 2 HVAC PIPING FLOOR PLAN
M4.03 LEVEL 3 HVAC PIPING FLOOR R PLA N
M4.04 MECHANICAL PENTHOUSE HVAC PIPINGR
LOOR PLAN
' M5.00 SMOKE CONTROL SEQUENCE AND CALCULATIONS
M5.01 LEVEL 1 FIRE PROTECTION FLOOR PLAN
M5.02 LEVEL 2 FIRE PROTECTION FLOOR PLAN
M5.03 LEVEL 3 FIRE PROTECTION FLOOR PLAN
M5.04 MECHANICAL PENTHOUSE FIRE PROTECTION FLOOR PLAN
M7.01 I ENLARGED BOILER ROOM PLAN
M7.02 ENLARGED KITCHEN PLAN
M7.03 MECHANICAL SECTIONS
M7.04 MECHANICAL SECTIONS
M7.05 MECHANICAL SECTIONS -
M7.06 MECHANICAL SECTIONS
M8.01 MECHANICAL HEATING WATER SYSTEM RISER DIAGRAM
M8.02 MECHANICAL CHILLED WATER SYSTEM RISER DIAGRAM
M8.03 MECHANICAL WASTE AND VENT RISER DIAGRAM
M8.04 MECHANICAL GAS RISER DIAGRAM
M9.01 MECHANICAL DETAILS
M9.02 MECHANICAL DETAILS
1M9.03 . MECHANICAL DETAILS
M9.04 MECHANICAL DETAILS
M9.05 - MECHANICAL DETAILS
M9.06 MECHANICAL DETAILS
! MECHANICAL LEGEND
MECHANICAL ABBREVIATIONS AND GENERAL NOTES
MECHANICAL SCHEDULES
MECHANICAL SCHEDULES
MECHANICAL SCHEDULES
MECHANICAL SITE PLAN
; PLUMBING FOUNDATION PLAN
E0.01 ELECTRICAL LEGEND
E0.02 ELECTRICAL ABBREVIATIONS AND GENERAL NOTES
E0.03 LIGHTING FIXTURE SCHEDULE
E0.04
1E-61.-05
E1.01
E2.01
1E2.02
1E2.03
E2.04
1E3.01
i E3.02
!E3.03
E3.04
E5.01
E5.02
!E5.03
E5.04
- -- -- - -- - - ----------------------------
LIGHTING CONTROL DIAGRAMS
LIGHTING CONTROL DIAGRAMS
ELECTRICAL SITE PLAN
LEVEL 1 LIGHTING FLOOR PLAN
LEVEL 2 LIGHTING FLOOR PLAN
;LEVEL 3 LIGHTING FLOOR PLAN
MECHANICAL PENTHOUSE LIGHTING FLOOR PLAN
;LEVEL 1 POWER FLOOR PLAN
LEVEL 2 POWER FLOOR PLAN
LEVEL 3 POWER FLOOR PLAN
MECHANICAL PENTHOUSE POWER FLOOR PLAN
LEVEL 1 FIRE ALARM FLOOR PLAN
LEVEL 2 FIRE ALARM FLOOR PLAN
LEVEL 3 FIRE ALARM FLOOR PLAN
MECHANICAL PENTHOUSE FIRE ALARM FLOOR PLAN
E6.01 LEVEL 1 SYSTEMS FLOOR PLAN
-------- - -- -
E6.02 ! LEVEL
----EVEL 2 -------------- SYSTEMS FLOOR - - ------------
PLAN
!E6.03 ;LEVEL 3 SYSTEMS FLOOR PLAN
E6.04 ; MECHANICAL PENTHOUSE SYSTEMS FLOOR PLAN
E7.01 1ENLARGED TELECOM ROOM SYSTEMS PLAN
E7.02 ;ENLARGED TELECOM ROOM SYSTEMS PLAN
!ENLARGED KITCHEN PLAN
;TELECOM DETAILS
E7.03
E8.01
E8.02
E8.03
E8.04
E8.05
E9.01
71 Columbia
Seattle, West ,
T (206) 340 9!
CIVIL ENGINES"
KPFF
1601 Fifth Ave, Suite 1E
Seattle, WA 98101
T (206) 622 5822 F (20E
LANDSCAPE ARCI-
r
SiteWorkshop LLC i)T
1927 Post Alley
Seattle, WA 98101
T (206) 285 3026 F (206) 235\36.29
STRUCTURAL ENGINEER
PCS Structural -
811 First Avenue, Suite 620
Seattle, WA 98104
T (206) 292 5076 F (206) 467 7788
MECHANICAL & ELECTRICAL
ENGINEER -
Hargis Engineers
600 Stewart St, Suite 1000
Seattle, WA 98101
T (206) 448 3376 F (206) 448 4450
ACOUSTIC CONSULTANT
Sperling
720 Olive Way, Suite 1400
Seattle, WA 98101
T( 206) (206) 667 0555 F667 0554
FOOD SERVICES
JLR -Design Group.
557 Roy Street, Suite 175A
attle, WA 98109
06) 625 0070 F (206) 625 0073
DWARE
s Consulting
North 57th Street
le, WA 98103
06) 528-0244 F (206) 528-0138
REVISIONS
DESCRIPTION DATE
1 CORRECTION LETTER #2 05/28/10
2 CORRECTION LETTER #3 06/23/10
6073
REGISTERED
ARCH TECT
LY BROCKMAN
STA CF W\SHI NGTON
EYARATE_PERMIT
REQUIRED FOR:
TELECOM DETAILS
TELECOM DETAILS
I TELECOM DETAILS
TELECOM DETAILS
Mechan'•
I Electrical
robing
- --_. Gas Piping
of_Tukwila
E r 1 1-DMVISION
---------------------------- ----------- - - - - - - -
ELECTRICAL ONE -LINE DIAGRAM
F51.1 1FOOD SERVICE EQUIPMENT FLOOR PLAN AND SCHEDULE -
J.
FS2.1 ! FOOD SERVICE EQUIPMENT PLUMBING REQUIREMENT PLAN
; FS3.1 ;FOOD SERVICE EQUIPMENT ELECTRICAL REQUIREMENT PLAN
FS4.1 i FOOD SE VICE EQUIPMENT SPECIAL CONDITION REQUIREMENT PLA
Grand total: 226
CORRECTION
LTR#
co
EVIEWED
OR
IANCE
APPROVED
JUL 07 2010
w
City of Tukwila Z
5
BUILDING DIVISION
b10•04-61
HIGHLINE SCHOOL
DISTRICT 401
RAISBECK
AVIATION
HIGH
SCHOOL
JOB NO: -
ISSUE DATE:
DRAWN BY:
CHECKED BY:
09819
JUNE 23, 2010
CL
CL
COVER
SHEET
JUN?a-
i�
-,•
G0.01
IOCCUPNT LOAD (SECTION 1004)
NUMBER OF NUMBER OF OCCUPANTS EACH SPACE, NUMBER OF EXITS AND EXIT WIDTH REQUIRED:
SEE com ANALySIS PLANS FOR E.GRESS REQUIREMENTS PER Exrt EACH FIQOR.
4/22/2010 4:17:09 PM
GEN EQUIP
Occ.: E
Rate: 300
88 SF
Count:1 ,,
kr..„..0000000o
450.
EMERGENCY
COMM SYSTEM
Occ.: E
Rate: 300
99 SF V
' Count:1
EXTERIOR
LOADING.
AREA
032"/36"
F32" 36"
STOR
Occ.: E
Rate: 300
164 SF
Count:1
CLASS III STANDPIPE W/
HOSE CONNECTION EACH
FLOOR, TYP.
CUSTODIAN
Occ.: E
Rate: 300
120 SF
Count:1
55555 .5,5":0554.545015-5415I5:55:,5
544,K
1
CONFERENCE
Occ.: E
Rate:100
306 SF
Count:4
OFFICE
Occ.: E
Rate:100
332 SF
Count:4
EMP.5ve%*. .•50:MMEMOKEEM:MMEM.4;v:MB.M.M.WP"'""'""
5%'"I5,50=5:&5550'""",:":"''5M0'55.5M1IMI=Z•55.,. MI5175555.505&/
4
32"/72"
t•4
:54
„,", •
5 6
55,5,55;v55,5,55,55,54555`45,5,055,5,55,5,:g
BOILER
Occ.: E
Rate: 300
1020 SF
Count:4
1
•
1
1
1
0
1
1
1
1
:
MULTI-PURPOSE
ROOM L.
Occ.: E
R 7
17 SF"-"",
Count:310/
3
[32"/48"
-65WW:5•M/5:5500.:M:LZ55K55;15M555555,00555.5=57M751B-0m-55,-2z:moum=g00..0mmworgmES:gaMgat.EA
LOADING/HOLDING
Occ.: E
Rate: 300
298 SF
Count:2
• g
ST EL
ELEV. MACH
Occ.: E
Rate: 300
79 SF
Count:1
111
,
-132"/ 36"
_i /'
pfai
••••••••• •-•,a,"1".""
' ...••••525X: -
155
32"/72"
TELESCOPIN
SEATING
EXTENDED.
224 SEATS
(1600 SF)
4
OFFICE
Occ.: E
Rate:100
250 SF
Count:3
OFFICE
Occ.: E
Rate:100
141 SF
Count:2
?j'54
RECEPT. WORK AREA
Occ.: E Occ.: E
Rate:100 Rate:100
125 SF 389 SF
Count:2 ; Count: 4„4
H.E. REFUGE AREA.I.
32/0.15=213
/
101 4•,
213X3 SF=639 SF4. H.E. 9 .1
32„/72,, ..,32"/8
32"/36" A7 ,
17 32"/72"
555455555544454452,5750,7
SEATING EXTENDED: 82+224 = 306
SEATING RETRACTED (2173 SF)
2005,5492000 -
L 108' MAX TRAVEL PATH
32"/36"
7,10W5m55f:Z4W
ELECTRICAL
ROOM
Occ.: E
Rate: 300
197 SF
Count:1
LEVEL 1 CODE ANALYSIS PLAN
1/16" =
LAUNDRY
Occ.: E
Rate: 300
61 SF
Count:1
OFFICE
Occ.: E
STOR
Occ.: E
Rate: 300
285 SF
Count:1
I.`5:5541515.55 TEMIIIMM555E5 55:5M5MII5E55755Z5MAM
Rate:100
75SF 1
Count:1
,32436",
DRY STOR
Occ.: E
Rate:300
87 SF
Count:1
o 1
0g /32/36
iggelmr,szsommolf
KITCHEN
Occ.: E
Rate: 200
1084 SF
Count:6
4.55,55.5,50,0555544,..,
EST EL
MESE-004-50.
LEVEL 2 CODE ANALYSIS PLAN
,
1
5
\-
3 I 2
32"/36" 32"/36"
32"/36"1
4
55U7,550".../.5"5"5"'"545555'5,5,5,57,557/...,5 &45:445.A.4.4:4'
H.E. REFUGE AREA:
32"/0.15=213
213X3 SF=639 SF
-------
.„.
1
.‘ 20E:NM00:05ENtS.A0 y1 - 11i 1 -rA 11I #°°tI 2
32"/36" 3"/36"32"/3 j32"/36'32"/36"22"/36"32"/ 3 6".1k„332",
36".
//// 3/z - a ..--
" . .0 " WEVAI.M
-----
, 2
STOR
Occ.: E
Rate:300
78 SF
Count:1
LOBBY
Occ.: E
Rate:15 •
1395 SF
Count: 93
H.E. REFUGE AREA:
:,.p1 32"/0.15=213
213X3 SF=639 SF
ae-'21`4::db
H.E.
STOR GREEN RM
Occ.: E Occ.: E
Rate:300 Rate:20
165 SF 90 SF
Count:1 Count:5
GREEN RM CONF CONF CONF IT
Occ.: E Occ.: E Occ.: E Occ.: E Occ.: E
Rate: 20
94 SF
Count:5
ELE 1>
32"/36w/36"
REGIST. HEALTH OFFICE STOR
Occ.: E Occ.: E Occ.: E Occ.: E
Rate:100 Rate:100 Rate:100 Rate:300
103 SF 297 SF 82 SF 43 SF
Count:2 Count:4 Count:1 Count:1
3 '/36"
11
0.
r
4
a2"./36"._
,
32"/36"
/111/1
0.5:50.0554,0,50554-505.05,, -4505
106
138' MAX TRAVEL PATH
"/72"
."777771
4 :155055:0:5&..4
•
15/5i ;
1
AI.e•-3
39 Lilo;
32"/36" PHYSICS LAB
Occ.: E
Rate: 20
1496 SF
Count:76
1132' 3
......
CLASS I STANDPIPE W/
HOSE CONNECTION EACH
FLOOR, TYP.
MDF
Occ.: E
Rate:100 Rate:100 Rate:100 Rate:100 Rate:300
93 SF 92 SF 92 SF 105 SF 144 SF
Count:1 Count:1 Count:1 Count:2 Count:1
AV ROOM
Occ.: E
Rate:300
43 SF
Count:1
H.E. REFUGE AREA:
32/0.15=213
213X3 SF=639 SF
•
OPEN TO BELOW
COMMON?
Occ.: E
Rate:15
5124 SF
Count:417
SEATING EXTENDED: 303+114 = 417
SEATING RETRACTED (5,124 SF) = 342
551
4.
5•••
-,,.,....„,,:r411 1,..,
FLEA 08.p( 1-1E108
32"/.:36" ......32"/36"`\
''''
,
• .0..L. /
•
321‘36.1: 55, /5555 v51
eg 1. 11.144.
OFFICE
Occ.: E
Rate:100
112 SF
Count:2
H.E. REFUGE AREA:
32/0.15=213
639 SF
ELESCOPI
SEATING
EXTENDED:
114 SEATS
(585 SF)
EFUGE AREA:
32/0.15=213
213X3 SF=639 SF
rg:
-----
Ea.
Rate: 3.t
23t,
Count:
132"/36"r
1 T1
Ty. . cr. - •
4 1
r
H.E.1 07 ,'-`11.E. 1 V7
6 : ..1,r:-
32"/36" 32"/36"
0
05.- I.:7.5 •
05500.4.5-.0550.550
1
(127
32"/36"..
UP
STUDENT
STORAGE
Occ.: E
Rate: 300
81 SF
Count:1
STOR
Occ.: E
Rate: 300
110 SF
Count:1
IA
' 38
32"/36"
CLASSROOM
Occ.: E
Rate:20
1
803 SF
Count:41
• • 0,
,55.5550.5N115.5v .55.55.55.5550,555555.55-5,55,55,5-5555,
•
V ri E:
38
2"/36"
• .
,•••",,,;55.'5,5555555- ..
554
OFFICE CAREER CENTER OFFICE
Occ.: E Occ.: E Occ.: E
Rate:100 Rate:100 Rate:100
113 SF 504 SF 159 SF
Count:2 Count:6 Count:2
0:00500.0r.•-••••,•••••••••••"
6"!32"/36"q
0 2
444
13
36"
2
BREAK ROOM
Occ.: E
Rate:15
65 SF
Count:5
:10:3200r
•
STORAGE
I A
Occ.: E
"/36"
Rate:100
...144 4...44:4444.444/E4
1:545,4•0:4,
CENTRAL STAIR
Occ.:E
Rate:i 5
1167'SF
Count:78
DN
H.E. REFUGE AR
32"/0.15=213
13X3 SF=639 SF
STOR
Occ.: E
Rate:300
83 SF
Count:1
55:00.5500/55,54-
.......
GENERAL
CIENCE LAB s;
Occ.: E 32"/36"
Rate:20
1444 SF
Count: 73
27- -
32"/72"
CLASSRM
Occ.: E
Rate:20
918 SF
Count:46
E5=5,,57Sa5=MVIO75,
SM PROJ LAB
Occ.: E
Rate:20
826 SF
Count:43
<43
105 32"/36"
32"/72"
MACH LAB
Occ.: E
Rate: 50 ri
1747 -SF •
Count:
•
32136" 132136"
46 LL 44
..........,........ .....,,,,...„.7
CLASSRM
Occ.: E
Rate:20
880 SF
Count:44
55505055455 ...45,5,55545.55555,
0k;owitiorstitri$,*,61
• moml 29
SOUTH TERRACE
Occ.: E
• Rate:15
394 SF
Count:27
MOM
36
32"/36"
.444
44/4
WEL P
32" 00
32" 36111,:11
7717
abr
....
I :
4444444
1
/132"/36"
/
CLASS III STANDPIPE W/
„.. HOSE CONNECTION EACH
FLOOR, TYP
•
o
..,...:,4,....,
.32"
36"
55•E
4..5: .
4E7E0
4155505515500'5045500
48
MAT STOR
Occ.: E
Rate:300
83 SF
Count:1
COMP ROOM
Occ.: E
Rate:300
47 SF
Count:1
IDF
Occ.: E
Rate:300
52 SF
Count:1
32"/36"
T STAI
f0455.550.., -
mo• -••=4,z-04
36"
Rate:20 \N •
487 SF A
Count:24
H 137
32"/36"
`11707rogr
FLEX
Occ.. E
32'36"
Q
CAD LAB
Occ.: E
Rate:20
1181 SF
Count:58
PREP/STORAGE
Occ.: E
Rate:100
350 SF
Count:4
29
32"/36"
41/17444
42
32"/36" CLASSRM
Occ.: E
Rate:20
782 SF
Count:41
CO.
44
00100 0=-"-"`"'
TRUE
NORTH
EAST TERRACE #1
Occ.: E
Rate:15
316 SF
Count: 23
JAN
Occ.. E
Rate:300
94 SF
Count:1
CLOSET
Occ.: E
Rate:300
13 SF
Count:1
TRUE
NORTH
1/16" = 11-0"
STOR
Occ.: E
Rate:300
174 SF
Count:1
ELEC IDF
Occ.: E Occ.: E
Rate:300 Rate:300
159 SF 134 SF
Count:1 Count:1
STORAGE
Occ.: E
Rate:300
89 SF
Count:1
15-0 751
'orrY15:055:::5 44.557555.•;:r 5 ;5555,, 0040.000.....
CLASSRM
Occ.: E
Rate:20
861 SF
Count:42
32"/36"
43
FLEX
Occ.: E
Rate:20
386 SF
Count:20
FEc„
VVBF
55•;55.5555M501=55555ath53315'„00005
CLASSRM
Occ.: E
Rate:20
936 SF
Count:47
NEENI
W.COMMM11111,11111111111.44,,MMOMMAMOZMM.
eMOW
• 7444444444441777:
A "
47
32"/36"i:,;
,0
40M;re.g
44
144*111.
CLASSRM
Occ.: E
Rate:20
941 SF
Count:48
...
4 0
STORAGE STAFF LOUNGE CLOSET
Occ.: E Occ.: E Occ.: E
Rate:300
108 SF
Count:1
PRO LEARNING
Occ.: E
Rate:20
928 SF
Count:46
32"/36" '032736"
48 t 47
V 1111,111F1•1111-
f/
454
• 1
:55-54444
1I5I5
L141
Rate:15 Rate:300
873 SF 21 SF
Count:58 Count:1
• „ „„
ir5
550
32"/36"
29
32"/36" 110 /0 4• 11
----45,10•1555,505,4
AWINF:100:'
0, ..
'----
NCE
32"/36";'1 Rate:15
RAVEL DiTAH.E. REFUGE AREA:
38"/0.15=253
5F=759 SF
5- 55 55:5,..%5.55,.5:5:
CLASSRM
Occ.: E
Rate:20
933 SF
Count:47
r
55 055105,7
A N i
47i
, o
32"/ 36"F.
44
32"A36"
LEVEL 3 CODE ANALYSIS PLAN
CLASSRM
Occ.: E
Rate:20
868 SF
Count:44
1.
44
44
44
CLASSRM
Occ.: E
Rate:20
946 SF
Count:47
H.E. 30
32"/36"
44
NORTH TERRACE
Occ.: E
ate:15
202 SF
Count:14
STORAGE
Occ.: E
Rate:300
89 SF
Count:1
• oo..,,072,,, '555'5
14
CLASSRM
Occ.: E
Rate:20
947 SF
48 Count:48
32"/36"
"•11
,055554150: 11,4
5. 4
H.E. REFUGE ARE
32"X0.15=213
213X3 SF=639 SF
.... ,
....................
74
.50.5555,
444
CLASSRM
Occ.: E
Rate:20
977 SF
Count: 49
CLASSRM
Occ.: E
Rate:20
958 SF
ount:47
IDF
Occ.: E
Rate:300
84 SF
Count:1
---055:55:551=
4444
32"/36"
CENTRAL S
Occ.:E MAI
H.E.189 -A,
,
c 100u7n7t : SF
32"/42",:12,4*11, 40'
/:211".EH..E. REFUGE AREA.
253X3 SF=759 SF
1 I
44
ft:M0.0.0505rk.ril
DN
38"/0.15=253
161 36"
„ mmdmg
olgEgr=mmt egIMMIUMIN
CLASS III STANDPIPE W/
HOSE CONNECTION EACH
STAIR, TYP.
STOR
Occ.: E
Rate:300
122 SF
Count:1
44
44
%26
32"/36"
FLEX
Occ.: E
Rate:20
...3611 491 SF
Count:24
5 \1$,
(138
32"/36"
I 5;44171
6 • Ai:
36
37 32"/36"I
CHEMISTRYLAB
Occ.: E
Rate:20
-1450-SF
Count:73
32"/36"
4555100,0,0- .. , ... ZEE -4
:,0005,,,,,,455,4•5555,05,4,05•57
VEL DISTANCE
,A5 .. .
# 29
32"/36"
32"/36"
138
32"/36"
29
BIOLOGY LAB 32'136"
Occ.: E
Rate:20
1216 SF
Count: 58
PREP ROOM
Occ.: E
Rate:100
351 SF
Count:4
/4224*
":55.45.00:5 s
55,
,555545•55
EAST TERRACE #2
Occ.: E
Rate:15
362 SF
Count: 26
5,0:,5,4,Ac5K
5,5555.5.55,5555.400 010
5 '0.45
•;.%
42 44
32"/36" CLASSRM‘
Occ.: E
Rate:20
805 SF
Count:41
-
4-/44411444/44/,
STOR
Occ.: E
Rate:300
13 SF
Count:1
JAN
Occ.: E
Rate:300
94 SF
Count:1
TRUE
NORTH
1/16" = 110"
SMOKE CONTROL
EQUIPMENT
ROOM
Occ.: E
Rate:300
291 SF
Count:1
1
32"/36"
WES
LT
, A
-41
MOMMCW MO' MM., /1 MOMOMM, h V MWOOMOMMOMMOMMO.
3211/6".,
........
00*
.••
RIMMCOMMI MOMMOMMOMMOYMMOWCOMACOMMMMCCIMAMOOMMOMM,MOMMCCOM MOW.OMMWOMMOMMOMMOMMOOMMWM MOMMOW,MMOVA 1.4.0111147.7
RAVEL DISTANCE
WEST /
MECHANICAL/
PENTHOUSR
E j
Rate:300
4563 SF
Count:16
7....74 COW MOMIMMOMMOMMOMMWMI M44444,..,,MCCOMOW.MMOMM,WWM
OPEN TO
STAIR #1
BELOW
ELE
FA •
ELEV MACH
Occ.: E
Rate:300
56 SF
Count:1
MECHANICAL PENTHOUSE
1/16" = 11-0"
EAST
MECHANICAL
PENTHOUSE
Rate:300
3756 SF
Count:13
,-•
44
R.6,YESJD145„,TAlicE
44744
11*11*15
36"/60"K
IR 1
32"/36"°'
.... 1
i • • I
15
32"/36"
SMOKECONTROL
EQUIPMENT
•ssA. ROOM
• Occ.: E
Rate:300
, 165 SF
\‘'‘
Count:1
CLASS 111 STANDPIPE W/
HOSE CONNECTION, EACH
STAIR TYP.
/".
TRUE
NORTH
'CODE NOTES (2006 IBC)
APPLICABLE CODES
1 =YE TUKWILA MUNICIPAL CODE
2 CITY OF TUKWILA ZONING CODE
2 I1TERNATIONAL3 WI -DING CODE (D3C), 2006 EDTTION; WASHINGTON STATE AMENDMENTS, WAC 51-50*
INTER_NATIONAL MECHANICAL CODE (IMC) 2006 EDITION, WASHINGTON STATE AMENDMENTS, WAC 51-52*
4TNTERNATI0NAL FIRE CODE- gq, 2006 EDITION, W.A.SHINGTONSTATEAA4ENDRIENTS, WAC 51-54*
5:NATIONAL ELECTRIC CODE (NEC), 2008 EDITION,WASHINGTON STATE AIVIENDMENTS
6.UNIF ORM PLUMBING CODE (UPC) AND UNIFORM PLUMBING CODE STANDARD, 2006 EDITION WAC 51 56AND 5157*
7 INTERNATIONAI,FUEI., GAS CODE OP GC), 2006 EDITION, WASHINGTON STATE AMENDMENTS
&WASHINGTON STATE ENERGY CODE 2006 EDITION WAC 5111*
WASHINGTON STATE VENI'ILATION AND IND.00R. AIR QUALITY CODE, 2006 EDITION, WAC 5113*.
10 ACCESSIBILITY CODE ICC/ANSI A117.1-2003
*CURRENT WASBINGTON STATE AMENDMENTS ARE DATED JULY 1, 2007
USE GROUP (C1{APTER3)
EDucATJorz,$cH9QL. GRADE
*2: ASEMBLY; FOOD & DRINK :CONSUMPTION. (FORMEANS. OF EGRESS ONLY)
*3: ASSEMBLY; GYIVINASIUMFOR1VIEANS;OF gpi3.Es$4:)m,y)
TYPE OF CONSTRUCTION
1.-B FULLY :SPRINKLERED (SECTION602.2)
NONCOMBLISTIBILE.CONSTR.UCTION
'SPECIAL DE TAILED REQUIREMENTS
ATRIUM (GYMICO1VILVIONS)
AUTOMATIC SPRINICLER PROTECTION
SMOKE CONTROL (NOT APPLICABLE)
ENCLOSURE OFAIRIUM
ATRIO/vI STANDBY POWER
INTERIOR FINISH . .
TRAVEI; DISTANCE.(SECLION 404.8)
AUTOMATIC -SPRINKLER SYSTEM
HIGH-RISE BUILDING (CITY OF TUKWILA.)
SECTION4O4
SECTION 404.3
SECTION 404.4; REQUIRED FOR ATRIUMS'THATcoNNEcr MORE THA.NTWO STORIES
SECTION 404.5
NOT REQUIRED
CLASS B.OR GREATER
<200 FEET IN CTI-TFR. THANT LOWER LEVEL OF ATRIUM
SECTION 410.6, ORDINARY HAZARD PER TMC CHAPTER 16.42.070
TMG CHAPTER 1648
HEIGHT AND NUIVIBER OF STORIES (SECTION504 AND TABLE 503)
:ALLOWED
MAXIMUM. HEIGHT. (FEET): 160 FT
1vLACEMUM NUMBER OF STORIES 5
• PROPOSED
. 53 FT
3 (PLUS MECHANICAL PENTHOUSE)
"ALLOWABLE FLOOR AREA (TABLE 503)
1
MAXIMUM FLOOR AREA;
.UNLDETED
'PROPOSED FL OOR AREA
FIRST FLOOR
SECOND FLOOR
THIRD FLOOR
MECHANICAL PEII'FIOU SE
I OTAL BUILDING FLOOR AREA
21,005 SF
25,763 SF
.26,863 SF
12,726 SF
36,357 SF
IFIRE-RESISTANCE RATING REQUIREMENTS FORHWIDENG ELEMENTS (TABLE 601)
ELEMENT'
STRUCTURAL FRAMEINCLUDING:COLITIvINS; BEAMS; GIRDERS TRUSSES
BEAR.INGWALLS;EXTERIOR'
BEARING WALLS, INTERIOR
NON-BEARING WALLS AND PARTTITONS,-EXTERIOR
NON-BEARING VALLS A.ND PAREELIONS;INTERIOR
FLOOR CONSI RUCTION INCLUDING SUPPORTNG BEAMS AND JOISTS.
ROOF CONSTRUCTIONINCL1JDING SUPPORTING BEAMS AND JOISTS
RATING (HRS)
2
REDUCED EY 1 PIR:WHERE
SUPPORTING A.ROOF
ONLY:
2:
OR AS REQD BY TABLE
602
2
REDUCED BY 1 BR WRIERE
SUPPORTING A ROOF
ONLY
*TABLE 602
0
OR AS R.EQD BY OTHER
SECTIONS
NOT REQUIRED IF EVERY
PART OF.ROOF CONST.. IS.
20OR MORE ABOVE .ANY
FLOOR IMMEDIATELY
BELOW
IFIRE-RSISTANCE RATING - EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE (TABLE 602)
DISTANCE (FEET) TO INTERIOR PROPERTY LINE OR CENTERLINE OF STREET OR ALLEY.
<5
• 5 TO<10
10 TO <30
30 OR >
RATING (ERS)
1
VIRE BARRIERS (CHAPTERS 7 AND 10)
, . .
SHAFT ENCLOSURES CONNECTING LESS THAN 4 STORIES (SECTION 70)
ATRIUM WALLS
VERTICAL EXIT ENC.:I-OM-RES (STAIRWAYS) LESS THAN4 STORIES (SECTION 1019)
EXIT PASSAGEWAYS (SECTIONS 706, 1020)
HORIZONTAL EXIT FIRE BAR.RIERS (SECTION 1022)
INCIDENTAL USE AREAS (SECTION 302)
FIRE WALLS (SECTION 705)
CORRID OWALLS.(sEgnoNis 708,1016.1)
EXTERIOR EXIT RAMPS AND STATRW.A.YS (10216.3 EXCEPTION 3)
ASSEMBLY RATING
(HOEIR.S):
OPENING
RATING
(HOURS):
1 (2 TT -MU 2ER FLOOR.S)
1 1/2
3(4
1 (2 THRU 2 HR. FLOORS)
1 1/2
NIA
NIA
2
1 1/2
SEE TABLE BELOW
2 (NOT APPLICABLE)
11/2 (1\17A)
0
INCIDENTAL USE AREAS (TABLE 503.2-)
SPACE TYPE
'SEPARATION
FURNA.CE ROOMS WITH >400,000 BTU EQUIP.
BOIT-ER. ROOM 'WITH BOILER >15 PSI AND 10 HP.
I -AB ORATORIES AND VOCATIONAL SHOPS
STORAGE ROOMS > 100544
1HOUR OR. PB.OVIDE AUTOMATIC FIRE EXT. &B.ESIST PASSAGE OF smoKE.•
1 HOUR OR PROVEDE AUTOMATIC FIRE EXT & RESIST PASSAGE. OF SMOKE.
1'HOUR OR PROVIDE AUTOMATIC FIRE EXT.' &RESIST PASSAGE OF SMOKE.:
1 HOUR OR PROVIDE AUTOMATIC FIREEXT. & RESIST PASSAGE OF SMITE.
ITOTAL OCCUPANT LOAD (BY AREA)
FIRST FLOOR (LEVEL 1)
SECOND FLOOR (LEVEL 2)
THIRD FLOOR (LEVEL 3)
MECILANICAL PENTHOUSE
TOTAL
668
871
870
32
2,441
'EGRESS WIDTH PER OCCUPANT SERVED (TABLE 1005.1)
ELEMENT WITH SPRINKLER SYSTEM
STAIRWAYS
pTH ER:EG R RS'S COMPONENT
WIDTH. INCHES PER OCCUPANT
0.2
0.15
MAXIMUMFLOOR AREA ALLOWANCES PER OCCUPANT (TABLE 1004.1.1)
ASSEMBLY WITH: FIXED SEATS
ASSEMBLY WITHOOTFIXED stwrs
CONCENTRATED (CHAIRS)
UNCONCENTRATED (TABLES & CHAIRS)
EDUCATIONAL
CLASSROOM
SHOPS AND OTHERVOCATIONAL
OFFICES
EXERCISE ROOMS
KITCHENS
ACCESSORY STORAGE, MECHANICAL EQUIPMENT
SEE 1003.2.2.9
7.NET
15 NET
20. NET
50 NET
00 GROSS
50 GROSS
200 GROSS
300 GROSS
'MEANS OF EGRESS (CHAPTER 10)
MAXIMUM -TRAVEL DISTANCE FOR ,A AND E OCCUPANCIES, WaH SPRINKLER SYSTEM
DEAD END CORRIDORS
COMMON PATH OF EGRESS TRAVEL
250 FEET (TABLE? 1016.1)
20 FEET MAX. WHERE mogETHAN 'ONE
£IXIT1S R EQUI RED (S noN 1617.3)
75 FEET MAX; (SECTION 10143)
MINIMUM NUMBER OF EXITS EOR A AND E OCCUPANCIES (TABLE 1015] - AND SECTION 10191
MAXIMUM NUMBER OF OCCUPANTS
NUMBER OF EXITS REQUIRED
49
1
500
2
1,000
3
MORE 'THAN 1.000
--
TOILET EIXTURE.REQUIREMENTS (CHAPTER 29) WA AMENDMENTS:
E OCCUPANCY: 5 LOOOSF 100SF PER PERSON := 510 PEOPLE
LOAD DI STR IBUDON
WATER closErs
URINALS
LAVATORIES
BOYS ii.:i.; 0% = 255 TOTAL
1 PER 40 = 7 WCS
REDUCED FOR
URINALS = 2
WC'S MIN.
URINALS
1 PER 2 WCS OR
URINALS -
4 LA VS MIN.
GIRLS @ 50% = 255 TOTAL
1 PER 30 0-- 9 WCS
MIN.
--
1 P44442 WCS 00
5 LAYS MEN.
STAFF44P 1:20 = 26 TOTAL
16 T.0 35 PEOPLE' - 2
WCS MIN.,,,,
--
1 PER 2 WCS OR
URINALS- I LAVS
‘,,-.
A OCCUPANCY COMMONS/MULTI-PURPOSE ROOM). 7.778SF 4444 30SF PER PERSON = 260 PEOPLE
LOAD DISTRIBUTION
WATER CLOSET'S
URINALS
LAVATORIES
BOYS q .5o% = 130 TOTAL
126-200 = 4 WCS
REDUCED FORURINALS
URINALS 00
1 WC MIN.
3
1 PER 2 WCS OR
URINALS
2 LAVS MIN.
GIRLS c41450%= 130 TOTAL
126-200 =
4 WCSMIN.
--
1 PER 2 WCS 00
2 LAYS MIN.
TOTAL REQUIRED
188
14
TOTAL PROVIDED
19
8
14
PRINKING FOUNTAINS (SECTION 29034 810 TOTAL = 3 DFS
SHOWERS: NON REQUIRED
"SERVICE SINK;2: MN.
REVIONED FOR
CODE COMPLIANCE
APPROVED
JUL 07 2010
City of Tukwila
BUILDING DIVISION
FIRE EXTINGUISHER REQUIREMENTS OM 906)
LOCATION
CLASS
SIZE
QUANTITY
REMARKS
KITCHEN
K
10LB
I
WITHIN 30 FEET OE COMMERCIAL KITCHEN EQUIPMENT
THROUGHOUT OTHER AREAS
ABC
MINIMUM RATED SINGLE FIRE EXTINGUISHER: 2-44 LOCATE
ALONG NORMAL PATH OF TRAVEL; ORDINARY HAZARD,
MAXIMUM FLOOR AREA PER FIRE EXTINGUISHER: 11,250 SF
MAXIMUM TRAVEL DISTANCE .-- 75 FEET
CODE ANALYSIS LEGEND
40
32"/36"-.
Room name
Occ.: E
Rate:20
150 SF
Count: 40
2 HOUR SHAFT FIE BARRIER
2 HOUR RATED HORIZONTAL EXIT FIRE BARRIER
SMOKE RESISTANT
GENERAL DIRECTION OF EGRESS
OCCUPANT LOAD SERVED BY THE MEANS
OF EGRESS (H.E.=HORIZONTAL EXIT)
REQUIRED WIDTH/ PROVIDED EGRESS WIDTH (NOMINAL WIDTH AT DOORS)
• RECEIVED
APR 23 2010
PERMIT CENTER
CORRECTION
LTR#
ROOM TAG:
OCCUPANCY CLASSIFICATION
SQUARE FEET PER OCCUPANT
ROOM SQUARE FEET
OCCUPANT LOAD
•1(>' 03
LETTER #1
1...
0
0
bassetti
architects
71 Columbia Street, Suite 500
Seattle, Washington 98104
T (206)340 9500 F (206) 340 9519
CIVIL ENGINEER
KPFF
1601 Fifth Ave, Suite 1600
Seattle, WA 98101
T (206) 622 5822 F (206) 622 8130
LANDSCAPE ARCHITECT
SiteWorkshop LLC
1927 Post Alley
Seattle, WA 98101
T (206)285 3026 F (206) 285 3629
STRUCTURAL ENGINEER
PCS Structural
811 First Avenue, Suite 620
Seattle, WA 98104
T (206)292 5076 F (206) 467 7788
MECHANICAL & ELECTRICAL
ENGINEER
Hargis Engineers
600 Stewart St, Suite 1000
Seattle, WA 98101
T (206)448 3376 F (206) 448 4450
ACOUSTIC CONSULTANT
Spading
720 Olive Way, Suite 1400
Seattle, WA 98101
T (206) 667 0555 F (206) 667 0554
FOOD SERVICES
JLR Design Group
557 Roy Street, Suite 175A
Seattle, WA 98109
T (206)625 0070 F (206) 625 0073
HARDWARE
Adams Consulting
2337 North 57th Street
Seattle, WA 98103
T (206) 528-0244 F (206) 528-0138
REVISIONS
DESCRIPTION
DATE
1 CORRECTION LETTER #1 04/23/10
6073
REG STERED
ARCH TECT
STA
BROCKMAN
VIASHI NGTON
HIGHLINE SCHOOL
DISTRICT 401
RAISBECK
AVIATION
HIGH
SCHOOL
JOB NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
09819
APRIL 23, 2010
CL
JY
CODE
ANALYSIS
PLANS &
NOTES
G1.01
'3.
D
D.5
1'
--r
UZI
LEVEL 1
1/16" = 1'-0"
11
----------
•.,.****;7.*
LEVEL 2
1/16" =
.333
1
1
---
3
•
...
.
6}
----- • ••••----
/
---
5.6
.........................................
III
ji
11
111
1! 111111111.:
MLR
NE
313
*5=5;s:3.32ss*
,!* !!!`•
LEVEL 3
. . .4$
... ....
.. .................... .... .......
1111111111111111.......
§„.
5.6
1
A
9 .6
7-
'10.3
s,s;;;.s.*:4-is--3333,:z7!,1"- - •
5 ;
....... .
- 777-717i
' • =
E9)
:.••
1! :$
•
L.
•
9.6 10 10.3
.... ............
/I
$:$..,":4 1 %.7' .................... '"'
313
;;;;;;;;;;.4
I1
/-
12.3
:1$
7-7-frr •
'11.6
;IL
•
33
23
31
.........
J_11111_111.1.1.111L1111 11111111111111
11.'"f-,IffffIfff
9.6 10
3 1113 3,
10.3
311
IL
:*5
'12.3
............ -7:7*
I$
I• 1I$ $..$$
...................
31111113333
u.
„.j
„, ..X.•-$
•
14
11
........
:4:
...... . .
. ...
•
; ;
• V.
$ 5 ss
BEAM SUPPORT
FOR LANDINGi
BELOWa
14
ILA
TRUE
NORTH
3333
311.11111111113 s1:
TRUE
NORTH
1/16" = 1'-0"
LEGEND
COLUMNS
ALL COLUMNS ARE 2 HR SPRAYED FIREPROOFING UNLESS INDUCATED
OTHERWISE.
2 HR RATED INTUMESCENT PAINTED COLUMNS.
A5.41
SEE
FOR LIMITS OF INTUMESCENT ALONG GRID A.
2 HR RATED INTUMESCENT PAINTED
COLUMNS TO LEVEL 3
HORIZONTAL
ALL FLOOR DECKS, BEAMS & STRUCTURAL SUPPORT MEMBERS ARE 2
HR SPRAYED FIREPROOFING UNLESS INDUCATED OTHERWISE.
nal
hill
- 4
*$
LI
FC -02 NO SPRAYED FIREPROOFING. UNDERSIDE OF
DECK, COLUMNS, AND ALL OTHER HORIZONTAL
STRUCTURE SHALL HAVE 2 HR INTUMESCENT PAINT.
NON -RATED BEAM
2 HR RATED INTUMESCENT PAINTED BEAMS
1 HR RATED INTUMESCENT PAINTED BEAMS
NO SPRAYED FIREPROOFING UNDERSIDE OF ROOF
DECKS OR ROOF SUPPORTING MEMBERS.
t)10 4)3 I
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 07 2010
City of Tukwila
BUILDING DIVISION
RECEIVED
APR 23 2010
PERMIT CENTER
LETTER #1
0
0
0
bassetti
architects
71 Columbia Street, Suite 500
Seattle, Washington 98104
T (206) 340 9500 F (206) 340 9519
CIVIL ENGINEER
KPFF
1601 Fifth Ave, Suite 1600
Seattle, WA 98101
T (206) 622 5822 F (206) 622 8130
LANDSCAPE ARCHITECT
SiteWorkshop LLC
1927 Post Alley
Seattle, WA 98101
T (206) 285 3026 F (206) 285 3629
STRUCTURAL ENGINEER
PCS Structural
811 First Avenue, Suite 620
Seattle, WA 98104
T (206) 292 5076 F (206) 467 7788
MECHANICAL & ELECTRICAL
ENGINEER
Hargis Engineers
600 Stewart St, Suite 1000
Seattle, WA 98101
T (206) 448 3376 F (206) 448 4450
ACOUSTIC CONSULTANT
Sparling
720 Olive Way, Suite 1400
Seattle, WA 98101
T (206) 667 0555 F (206) 667 0554
FOOD SERVICES
JLR Design Group
557 Roy Street, Suite 175A
Seattle, WA 98109
T (206) 625 0070 F (206) 625 0073
HARDWARE
Adams Consulting
2337 North 57th Street
Seattle, WA 98103
T (206) 528-0244 F (206) 528-0138
REVISIONS
DESCRIPTION DATE
REGI STERED
ARCH TECT
STA OF VIASHI NGTON
HIGHLINE SCHOOL
DISTRICT 401
RAISBECK
AVIATION
HIGH
SCHOOL
JOB NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
09819
APRIL 23, 2010
Author
Checker
LIMITS &
TYPES OF
FIREPROOFING
G1.02
D.5
µ A
MECHANICAL PENTHOUSE
10, 10.3
'11.6
t is
12.3
4
BEAM SUPPORT
FOR LANDING
_BELOW.::::
15
1/16" = 1-0"
5.6
9
10 , 10.3
111.66
12.3 13
LEVEL 3 AND MECHANICAL PENTHOUSE ROOF
1/16" = 1'-0"
TRUE
NORTH
(ID
TRUE
NORTH
ilio
LEGEND
COLUMNS
ALL COLUMNS ARE 2 HR SPRAYED FIREPROOFING UNLESS INDUCATED
OTHERWISE.
2 HR RATED INTUMESCENT PAINTED COLUMNS.
SEE 15 FOR LIMITS OF INTUMESCENT ALONG GRID A.
A5.41
G2 HR RATED INTUMESCENT PAINTED
COLUMNS TO LEVEL 3
HORIZONTAL
ALL FLOOR DECKS, BEAMS & STRUCTURAL SUPPORT. MEMBERS ARE 2
HR SPRAYED FIREPROOFING UNLESS INDICATED OTHERWISE.
ALL ROOF DECKS AND ROOF FRAMINING MEMBERS SHALL HAVE 1 HR
SPRAYED FIREPROOFING UNLESS INDICATED OTHERWISE.
1■■■■
IMMEN
BNB
I'll'
•
FC -02 NO SPRAYED FIREPROOFING. UNDERSIDE OF
DECK, COLUMNS, AND ALL OTHER HORIZONTAL
STRUCTURE SHALL HAVE 2 HR INTUMESCENT PAINT.
NON -RATED BEAM
2 HR RATED INTUMESCENT PAINTED BEAMS
1 HR RATED INTUMESCENT PAINTED BEAMS
NO SPRAYED FIREPROOFING UNDERSIDE OF ROOF
DECKS OR ROOF SUPPORTING MEMBERS.
b10031
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JUL 0 7 2010
City of Tukwila
BUILDING DIVISION
RECEIVED
APR 2 3 2010
PERMIT CENTER
LETTER #1
Z
0
U
W
0
0
bassetti/
architects
71 Columbia Street, Suite 500
Seattle, Washington 98104
T (206) 340 9500 F (206) 340 9519
CIVIL ENGINEER
KPFF
1601 Fifth Ave, Suite 1600
Seattle, WA98101
T (206) 622 5822 F (206) 622 8130
LANDSCAPE ARCHITECT
SiteWorkshop LLC
1927 Post Alley
Seattle, WA 98101
T (206) 285 3026 F (206) 285 3629
STRUCTURAL ENGINEER
PCS Structural
811 First Avenue, Suite 620
Seattle, WA 98104
T (206) 292 5076 F (206) 467 7788
MECHANICAL & ELECTRICAL
ENGINEER
Hargis Engineers
600 Stewart St, Suite 1000
Seattle, WA 98101
T (206) 448 3376 F (206) 448 4450
ACOUSTIC CONSULTANT
Sparling
720 Olive Way, Suite 1400
Seattle, WA 98101
T (206) 667 0555 F (206) 667 0554
FOOD SERVICES
JLR Design Group
557 Roy Street, Suite 175A
Seattle, WA 98109
T (206) 625 0070 F (206) 625 0073
HARDWARE
Adams Consulting
2337 North 57th Street
Seattle, WA 98103
T (206) 528-0244 F (206) 528-0138
REVISIONS
DESCRIPTION DATE
6073
REGI STERED
ARCH TECT
LY BROCKMAN
STA OF VVkSHI NGTON
HIGHLINE SCHOOL
DISTRICT 401
RAISBECK
AVIATION
HIGH
SCHOOL
JOB NO:
ISSUE DATE:
DRAWN BY:
CHECKED BY:
09819
APRIL 23, 2010
Author
Checker
LIMITS &
TYPES OF
FIREPROOFING
G1.03
E21.142
RaisbeckAviationHigh School
9229EastMarginalWaySo
Duetothefilesize,thisrecord hasbeen brokendowninto6segments for
easierdownload.Clickonthefollowinglinkstoreviewthepermit
segments:
- Raisbeck Aviation High School D10-031
Tfhnfou!2
- Raisbeck Aviation High School D10-031
Tfhnfou!3
- Raisbeck Aviation High School D10-031
Tfhnfou!4
- Raisbeck Aviation High School D10-031
Tfhnfou!5
-Raisbeck Aviation High SchoolD10-031
Tfhnfou!6
-Plans -Raisbeck Aviation High SchoolD10-031
Tfhnfou7