Loading...
HomeMy WebLinkAboutPermit D13-0351 - SABEY CORPORATION - DATA CENTER - TENANT IMPROVEMENTSABEY DATA CENTER 3355 S 120 PL, UNIT 200 D13-0351 0 r----- rl„A w4 City of Tukwila Department of Community Development �= 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 s3 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: 1023049082 DEVELOPMENT PERMIT Permit Number: D13-0351 Address: 3355 S 120 PL Unit100 Issue Date: 12/17/2013 Permit Expires On: 6/15/2014 Project Name: SABEY DATA CENTER Owner: Name: SABEY CORPORATION Address: 4TH FLOOR , SEATTLE, WA, 98168 Contact Person: Name: GLENN PARRY Address: 12201 TUKWILA INTERNATIONAL BL , TUKWILA, WA, 98168 Phone: (206) 730-4983 Contractor: Name: SABEY CONSTRUCTION INC. Phone: (206) 281-4200 Address: 12201 TUKWILA INTERNATIONAL BL, SEATTLE, WA, 98168-5121 License No: SABEYCI033KM Expiration Date: 1/12/2015 Lender: Name: SELF FUNDED - INTERGATE EAST Address: DESCRIPTION OF WORK: REPLACE EXISTING BALLISTIC MANTRAP DOORS Project Valuation: $81,470.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Fees Collected: $2,186.54 Type of Construction: IA Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Public Works Activities: Cha n neli zation/Stri pi ng: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and ed this permit and know the same to be true and correct. All provisions of law and ordinances gov- this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development rmit and agree to the conditions attached to this permit. Signature: Print Name: Date: )::-1i--7 t,� This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 2: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 3: Maintain fire extinguisher coverage throughout. 4: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 5: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 6: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 7: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 8: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 9: All sprinkler system plans, calculations and the contractors Materials and Test Certificates submitted to the Tukwila Fire Prevention Bureau must be stamped with the appropriate level of competency seal. (WAC 212-80) • • 10: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 11: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 13: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 14: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 17: ***BUILDING PERMIT CONDITIONS*** 18: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 19: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 20: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 21: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 22: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0409 FRAMING CITY OF TUK•4 Community Developme5t Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188' http://www.TukwilaWA.gov • Building Permit No. ' ? - n Project No. lti t -S--13 Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 3355 S. 120th Place Tukwila, WA 98168 King Co Assessor's Tax No.: Suite Number: Floor: Tenant Name: Sabey Data Center 102304-9082 PROPERTY OWNER Name: Intergate East LLC Address: 12201 Tukwila International Blvd. City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Glenn Parry Address: 12201 Tukwila International Blvd. City: Tukwila State: WA Zip: 98168 Phone: (206) 730-4983 Fax: (206) 282-9951 Email: glennp@sabey.com GENERAL CONTRACTOR INFORMATION Company Name: Sabey Construction Inc. Address: 12201 Tukwila International Blvd. City: Tukwila State: WA Zip: 98168 Phone: (206) 281-4200 Fax: (206) 282-9951 Contr Reg No.: CCSABEYCI033K1\ Exp Date: 01/12/2015 Tukwila Business License No.: BUS -0102122 H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh First New Tenant: ❑ Yes m ..No ARCHITECT OF RECORD Company Name: Sabey Architecture Architect Name: Kara Anderson Address: ° 12201 Tukwila International Blvd. City: Tukwila State: WA Zip: 98168 Phone: (206) 281-8700 Fax: (206) 282-9951 Email: ENGINEER OF RECORD Name: ' Company Name: N/A Address: Engineer Name: City: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: ' c� cits.v. ) 11 c� Address: City: State: Zip: Page I of 4 BUILDING PERMIT INFORMATIO1 206-431-3670 Valuation of Project (contractor's bid price): $ 81,470 Describe the scope of work (please provide detailed information): Replace existing ballistic mantrap doors Will there be new rack storage? ❑ Yes Existing Building Valuation: $ Z.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 14 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC " Type of ' Occupancy per IBC 1st Floor 188,298 IA B 2nd Floor 183,369 IA B 3'd Floor 183,369 IA B Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers 14 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 • • PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS O F THE STATE OF HINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUT Signature: AGENT: Print Name: Glenn Pa Mailing Address: 12201 Tukwila International Blvd. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: 11/15/2013 Day Telephone: (206) 730-4983 Tukwila WA 98168 City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT ( QUANTITY ( PAID PermitTRAK $1,326:95 D13-0351 Address: 3355 S 120 PL Unit100 Apn: 1023049082 ,326.95.; DEVELOPMENT $1,326.95 PERMIT FEE WASHINGTON STATE SURCHARGE TOTAL FEES PAID BY RECEIPT: R426 R000.322.100.00.00 B640.237.114 $1,322.45 $4.50 $1,326.95 Date Paid: Tuesday, December 17, 2013 Paid By: INTERNATIONAL GATEWAY EAST LLC Pay Method: CHECK 5004135 Printed: Tuesday, December 17, 2013 12:58 PM. 1 of 1 I?SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $859.59 D13-0351 Address: 3355 S 120 PL Apn: 1023049082 $859.59 DEVELOPMENT $859.59 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R119 R000.345.830.00.00 $859.59 $859.59 Date Paid: Friday, November 15, 2013 Paid By: INTERNATIONAL GATEWAY EAST Pay Method: CHECK 5004068 Printed: Friday, November 15, 2013 4:13 PM 1 of 1 CRWYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. .� PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 .b13-0351 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 Pro' T \ 1*1 Type of Inspection. Ft fJeti -- AdnrJJes3:, c.. ( 2.0c/ Date Called: Special Instructions: 0 ,, -y (2 A P b.t, O Raj IdC.lpv -1 Date Wanted: "'4- — i t — (—( a.m. p.m. equest r4- r r-- Requester X(04- Phone No: JApproved per applicable codes. EJ Corrections required prior to a,4roval. COMMENTS: )(vv tv+.pi Ie Dat i/-/ El SPECTION FEE REQUIRED. Priof.to next inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. A INSPECTION NO. INSPECTION RECORD Retain a copy with permit i--0351 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: c- Ac3esi Type of Inspection: }—fit\,uJ 6 Address: 3-.)S k Z a L.- Date Called: . Special Instructions: Date Waanted:. — / — l y7r„� ...-".m. Requester: Phone No: NAPproved per applicable codes. ElCorrectionsrequired prior to approval. COMMENTS: Date: Z- 7-1 ❑ REINSPECTION FEE REQ RED. Prior to next inspection, fee must be paid t6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D/3- ops) -as-6 /4-5- c73 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Sprinklers: Fire Alarm: - Hood & Duct: Monitor: Type of Inspection: Address: 53 3 3 Suite #: " 5 / a -v +4- qac �/ �. Contact Person: Special Instructions: Phone No.: pproved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: - Hood & Duct: Monitor: Pre -Fire: 4(4 -ex / (S ile/A-/ b J AlSpe r` Oil c -i4 -Tesk- — 6 L ` - 2 C[Ai .2 ✓vtr-, Com. , s 1 CwwJ er L- - - Qk r/.TVq- --49i -7-5-1-- — g N AA) /-4/404-5 to - ena-is - 0-_ Needs Shift Inspection: Sprinklers: Fire Alarm: - Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: A s-----.�— Date: /W/V Hrs.: y ro.xj $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form. 60C-- 6/11/10 T.F.D. Form F.P. 113 7/1/2014 City of Tukwila Department of Community Development GLENN PARRY 12201 TUKWILA INTERNATIONAL BL TUKWILA, WA 98168 RE: Permit No. D13-0351 SABEY DATA CENTER 3355 S 120 PL Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/6/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/6/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, "'R)ai) Bill Rambo Permit Technician File No: D13-0351 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 )0 PLAN WEVIMMING SLIP ACTIVITY NUMBER: D13-0351 PROJECT NAME: SABEY DATA CENTER SITE ADDRESS: 3355 S 120 PL X Original Plan Submittal Response to Correction Letter # _ DATE: 11-15-13 Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: Building Di ision aWVk Works Alit\ AWL \-)S-- FA(113 Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete n DUE DATE: 1 1-19-13 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12-17-13 Approved n Approved with Conditions Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 SABEY CONSTRUCTION INC :A 1 Washington State Department of Labor & Industries • Page 1 of 4 SABEY CONSTRUCTION INC Owner or tradesperson SABEY, DAVID ARTHUR Principals SABEY, DAVID ARTHUR Doing business as SABEY CONSTRUCTION INC WA UBI No. 601 532 164 12201 TUKWILA INT'L BLVD SEATTLE, WA98168-5121 206-281-4200 KING, County Business type Corporation Governing persons DAVIDASABEY License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. SABEYCI033KM Effective — expiration 05/14/1997 — 01/12/2015 Bond HARTFORD FIRE INSURANCE CO Bond account no. 52BSBCQ3983 Received by L&I 12/20/2004 Active. Meets current requirements. $12,000.00 Effective date 12/31/2004 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601532164&LIC=SABEYCI033KM&S... 12/17/2013 GENERAL NOTES 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT"GENERAL CONDITIONS," AND BUILDING. STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP. DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9: THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL; CONNECT, OR SECURE" AS •REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS -BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON, 1 1. 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE: 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. ;I. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. SYMBOLS ELEVATION REFERENCE SYMBOL U DETAIL ID SECTION REFERENCE SYMBOL INDICATES FINISHED 1 SURFACES TO ALIGN DRAWING TITLE BAR TITLE DETAIL IDENTIFICATION DRAWING TITLE GRAPHICAL SCALE 0 1 2 3 FLOOR ELEVATION SYMBOLS 92'4' +1'-0" NOMINAL FLOOR ELEVATION HEIGHT (ABOVE/BELOW) DETAIL REFERENCE SYMBOL COLUMN AND/OR GRID LINE SYMBOL DIMENSION LINE: L ANGLE © AT CENTERLINE BUILDING SPACE / ROOM ID OFFICE SPACE NAME __ SPACE NUMBER 1127 DOOR SYMBOL DOCUMENT SHEET SYMBOL KEYED SHEET NOTES GLAZING SYMBOL REVISION NUMBER ARCH / INTERIOR ABBREVIATIONS ADJ ADJUSTABLE AFF • - ALT ALUM APC APPROX ARCH ACT AV . • BLDG BOT CAB • CL CLG CLR • COL CONC CONF DEMO DEPT DF: DIA DIFF DIM • DTL DW. DWG EA EL ELEC ELEV EQ • -ABOVE FINISH FLOOR ALTERNATE ALUMINUM - ACOUSTICAL PANEL CEILING - APPROXIMATE ARCHITECTURAL ACOUSTICAL CEILING TILE. AUDIO VISUAL BUILDING BOTTOM CABINET CENTER LINE ` CEILING CLEAR COLUMN CONCRETE CONFERENCE DEMOLITION OR DEMOLISH DEPARTMENT DRINKING FOUNTAIN DIAMETER DIFFUSER DIMENSION DETAIL DISHWASHER DRAWING EACH ELEVATOR ELECTRICAL ELEVATION EQUAL EQUIP. •- EQUIPMENT EXT FA FD FE FEC FFE FIN FLUOR FLR FO FOIC FTIC FURR GA GC GL GWB HC HDW HM HR INCL INFO INSUL LAV LF MATL MAX EXTERIOR FIRE ALARM FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR ELEVATION - FINISH - FLUORESCENT - FLOOR FACE OF - FURNISHED BY OWNER, INSTALLED BY CONTRACTOR - FURNISHED BY TENANT, INSTALLEID BY CONTRACTOR - FURRING - GAUGE GENERAL CONTRACTOR - GLASS - GYPSUM WALLBOARD - HANDICAPPED -HARDWARE - HOLLOW METAL (STEEL FRAME) - HOUR - INCLUDING OR INCLUDED INFORMATION - INSULATION -LAVATORY - LINEAR FOOT - MATERIAL - MAXIMUM STREET MAP MDF • MECH MEZZ MFR MIN MISC MTD MTL N/A NIC NTS OC OFF OPNG OVHD P. PART PERF PERIM - MEDIUM DENSITY FIBERBOARD MECHANICAL MEZZANINE -MANUFACTURER - MINIMUM MISCELLANEOUS - MOUNTED - METAL - NOT APPLICABLE - NOT IN CONTRACT - NOT TO SCALE - ON CENTER - OFFICE - OPENING OVERHEAD - PAINT - PARTITION -PERFORATED - PERIMETER PERP . - PERPENDICULAR PLAM - PLASTIC LAMINATE PLYWD PLYWOOD QTY - QUANTITY (R) RELOCATED RA • - RETURN AIR RCP - REFLECTED CEILING PLAN REC -RECESSED REF REFERENCE REFR -REFRIGERATOR REL -RELOCATE REV REVISION OR REVISED RM ROOM RO ROUGH OPENING RTD RATED SCHED :`-SCHEDULE SF SHT SIM. SPEC SPKLR SPKR SQ STD STL - SQUARE FEET/FOOT -SHEET - SIMILAR - SPECIFICATION - SPRINKLER -SPEAKER SQUARE STANDARD - STEEL STOR -STORAGE STRL STRUCTURAL STRUC -STRUCTURAL SYMM - SYMMETRICAL TBD - TO BE DETERMINED TEL - TELEPHONE OR TELECOM TEMP -TEMPERED THK - THICKNESS 1. PROJECT ADDRESS: SABEY DATA CENTER INTERGATE.EAST, BLDG. 5, FIRST FLOOR 335 S. 120TH PLACE TUKWILA, WA 98168 2. APPLICABLE CODES & ORDINANCES: A BUILDING CODES.::: INTERNATIONAL BUILDING CODE - 2012 B REGULATIONS & ORDINANCES NFPA C ACCESSIBILITY INTERNATIONAL BUILDING CODE - 2012 ICC/ANSI 117.1 ACCESSIBLE & USABLE BUILDINGS AND FACILITIES REVISIONS No changes shall be made to the scope of t rork without i pe prior approval of T;110^ri!a Building Division. 177.1 3 a; 3 will require a new plan submittal and may i; w:ude additional pian review fees. TENANT: SABEY DATA CENTERS INTERGATE.EAST 3355 S. 120TH PLACE SEATTLE, WA 98168 Tel: 206.243.0175 Fax: 206.243.0269 ATTN: JOHN SASSER 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION: ICC CONSTRUCTION TYPE IA FIRE RESISTIVE SYSTEM: SPRINKLERED OCCUPANCY TYPE: B (SERVER FARM) 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES: 2 HOURS EXIT STAIR ENCLOSURES: 2 HOURS CORRIDORS: 1 HOUR 5. EXITS: NO ALTERATIONS TO EXITS ARCHITECT/DESIGNER: SABEY ARCHITECTURE 12201 TUKWILA INTERNATIONAL BLVD. - 2004 SEATTLE, WA 98168 Tel: 206.281.8700 Fax: 206.282.9951 ATTN: SANDRA SUSKIC Email: sandras@sabey.com 6. PROJECT DESCRIPTION: REPLACE EXISTING BALLISTIC MAN TRAP DOORS SEPARATE PERMIT REQUIRED FOR: echanical [electrical Pfumbin 9 •as Piping City of Tukwila Stftl,'ING DIVISION BUILDING MANAGER: SABEY CORPORATION 12201 TUKWILA INTERNATIONAL BLVD. FOURTH FLOOR SEATTLE, WA 98168 Tel: 206.281.8700 ATTN: SANDRA SUSKIC GENERAL CONTRACTOR: ". SABEY CONSTRUCTION 12201 TUKWILA INTERNATIONAL BLVD. SEATTLE, WA 98168 Tel: 206.2 81.8700 Fax: 206.281.0920 ATTN: GLENN PARRY WA License: SABEYC1033KM PLUMBING ENGINEER: TBD - Bidder Design Build by G.C. MECHANICAL ENGINEER: TBD = Bidder Design Build by G.C. ELECTRICAL ENGINEER: TBD - Bidder Design Build by G.C. FIRE/LIFE SAFETY ENGINEER: TBD - Bidder Design Build by G.C. PLUMBING, MECHANICAL, ELECTRICAL, LIFE SAFETY PERMITS UNDER SEPARATE SUBMITTALS. TO TOS TYP UON UPS VCT VIF W/ WC WD W/O - TOP OF - TOP OF SLAB TYPICAL - UNLESS OTHERWISE NOTED - UNINTERRUPTED POWER SUPPLY - VINYL COMPOSITE TILE - VERIFY IN FIELD - WITH - WATER CLOSET -WOOD - WITHOUT PARCEL NUMBER: 102304.9082 LEGAL DESCRIPTION: PARCEL D (BUILDING 21-05) G0.0 COVER SHEET / PROJECT INFORMATION G0.1 PROJECT NOTES G0.2 SITE PLAN Al.0 FLOOR PLANS AND DETAILS LOT 5, BOUNDARY LINE ADJUSTMENT NO. L02-057, RECORDED UNDER RECORDING NO. 20030327900002, AS AMENDED BY RECORDING NO. 20030725001852, RECORDS OF KING COUNTY, WASHINGTON. FIRST FLOOR KEY / EXITING PLAN - 1" = 40'-0" NO ALTERATIONS TO EXISTING EXITS It NO. SI* eporovai is subject to errors and omissions. ruction ume oesuhrl fy adopted code o ordinan . Recei d Cop an coNlitiA s is wled�e ' I i City1b iia UILDI G D SION AREA OF.WORK EXISTING EXIT DOOR DEFINITIONS AND DIMENSIONS A. DEFINITIONS: 1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. 5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. B. DIMENSIONS: lII11111117 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED. 00 000-0 0000 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. A. STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIE3ILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF". muumuu nd1 6. CEILING HEIGHTS ARE INDICATED FRIDM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS ARE DRAWN DIAGRAMA'TICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. SP SABEY ARCHITECTURE seattle, washington 206.281.8700 sabey.com REVIEWED FOR • QDE COMPLIANCE 'Z "`' APPROVED • b41--, DEC 0 4 2013 Ci fTu lay BUILDINGoDIVISION 6194 REGISTERED CH EC A; A'A A 11 'SON STATE OF WASHINGTON COMMON IMPROVEMENT: BUILDING 5 NORTHWEST ENTRY MODIFICATIONS FIRST FLOOR intergate.e LOGY CAIVIPUB 3411 South 120th. Place Tukwila, WA RECEIVED CITY OF TUKWILA NOV 1 5 2013 PERMIT CENTER 10/17/13 BUILDING PERMIT MARK l DATE ( DESCRIPTION ISSUE: PROGRESS DATE: DRAWN BY: CHECKED BY: APPROVED BY: 10,17.13 BH SS PROJECT NO: FILE: 12-0702 IGE-5 NwBallistic All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. COVER SHEET PROJECT INFORMATION G0.0 PROJECTNOTE$ DIVISION I GENERAL CONDITIONS 01010 SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD". ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE SABEY ARCHITECTURE WITHIN TEN (10) DAYS OFT THE CONTRACTOR'S RECEIPT OF THE PLANS SO SABEY ARCHITECTURE TURF MAYMAKE T A LTERNA E SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL S SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL T THEIR OWN EXPENSE. REPAIR IR SAID DAMAGE A A C SYSTEMS INCLUDE BUT ARE NOT LIMITED TO SPRINKLER MODIFICATIONS, 4. FIRE/EMERGENCY , E PLACEMENT, AUDIBLE ALARMS,SMOKE AND HEAT DETECTORS STROBES, FIRE EXTINGUISHERE, AND EXIT SIGN PLACEMENT. 5. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR APPROVAL ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION WORK. SUBMIT TO ARCHITECT THREE (3) COPIES FOR APPROVAL. 6. MECHANICAL AND ELECTRICAL TO BE DESIGN BUILD UNDER SEPARATE PERMIT, 7. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE . C SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "NIL." (NOT IN AND DATA CABLES,OFFICE FURNITURE CONTRACT SUCH AS TELEPHONE, EQUIPMENT AND CONTRACT), MOBILE KITCHEN APPLIANCES. 8. CONTRACTOR TO PROVIDE ALL FIRE/EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CO D... ES. FIRE/EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE FIRE EXTINGUISHERS AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS,RS , .:. AND EXIT SIGNS. 9. EVERY ET XI DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 10. ANY MATERIAL USED IN CONSTRUCTION SHOULD MEET CURRENT FLAME CODE REGULATIONS. 11. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. DIVISION II SITE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR MATERIALS ANDEQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OFT TELEPHONES, ELECTRICAL, VOICE/DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED LABELING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION R THE PRICING PLAN SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING AREAS OR AS SPECIFIED TO PROVIDE ALIKE NEW FINISH". ADJACENT SH. 6. CONTRACTOR SHALL PR OVID E PLASTIC SHEETING GORO OTHER APPROPRIATE E BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DIVISION VI - ARCHITECTURAL CARPENTRY AND CASEWORK 06100 ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, BACKING,FIXTURE FRAMING, WOOD CURBS, BUCKS,. NAILERS, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. DIVISION VIII - DOORS AND WINDOWS 08100 - METAL DOORS AND FRAMES 1: PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2: DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME UNLESS OTHERWISE NOTED. 3. DOORS SHALL BE PRE -MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. PROVIDE SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. 08710 - FINISH HARDWARE ` 1. FINISH AND SPECIALTY HARDWARE INCLUDES `ALL ACCESSORIES TOOLS, AND FASTENERS REQUIRED FOR. HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THEW RK SHALL BE FURN 'H TCHING IN IN SIMILAR LOCATIONS. AND FINISH: QUALITY ALITY OF SPECIFIED S 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDU 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. FOR R PROVIDE TWO (2)KEYS FOR EACH LUCK AND TWO (2)MASTER KEYS O THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETSFOR ARCHITECT REVIEW. - OF BUTT HINGES ONE LATCHSET OR LOCK 5. ALL DOORS SHALL HAVE A MINIMUIM OF 1 1/2 PAIR , SET, AND ONE DOOR STOP TO MEET A.D.A. REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE. ; 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE. 08810 GLASS 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. THIS PROJECT CONTAINS GLAZING; HAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BIE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF . GLAZING SUBCONTRACTOR FINDS ANYTHING THE DOCUMENTS NOTIN WITH THE IN STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING CEEDING WITH THE WORK. DIVISION IX FINISHES 09250 GYPSUM YPSUM DRYWALLAND,MET METAL. STUDS INSTALLATION OF ALL MATERIALS, LABOR AND ACCESSORIES FOR THE 1. INCLUDE NECESSARY PARTITIONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE.BUILDING STRUCTURE UON. LATEST BUILDING CODES SEISMIC BRACING AS REQUIRED THEPER A 5. SEISMIC BRACING: PROVIDE (NEW CONSTRUCTION ONLY) TO THE PARTITION HEADS AND CEILING GRID. 6: FRAMING STUDS`. GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). .`.VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING; AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8: ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "MIR" TYPE DRYWALL . D WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS,. AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL. METAL EDGE TRIM AT AT WHENEVERGP ED. EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED SEMI -EXPOSED. 10. PRIOR TO RECEIVG'ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO ING FINISH, RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE DIAGONAL BRACING AS AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES ETC. ON BOTH SIDES OF CROSSING/PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLSFIRE-RATED SHALL BE PROTECTED BY APPLICABLE IR E -RATED ASSEMBLIES. 09530 - ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID. 09680 -: CARPET 1. PROVIDE COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. CARPET TO BE INSTALLED AS INDICATED IN DRAWINGS. 3. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4OVER 10'. 4. PROVIDESEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWOFINI H (2) COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED S C UAL: PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS. U MB E 2: FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. W DW RK T BE FINISHED WITH ONE 1 COAT PRIMER AND TWO A) PAINTED 00 0 O O , . (2) FINISH COATS. STAINED SEALED WOODWORK TO BE PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH: 3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3-B "CUSTOM" (2 COAT) GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT:. AWS SYSTEM 3-B "CUSTOM" (2 COAT) GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. COMPLETION OF WORK REMOVE EXCESS PAINT,STAIN, VARNISH,ADHESIVE,CAULK, 5. UPON ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. T 6. TOUCH-UP AND PATCH SURFACES AS REQUIRED U RED AF ER THE COMPLETION.OF WORK BY OTHER R TRADES. MN OCCURIN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE 7. WHERE COLUMNS SAME FINISH AS THE ROOM UON. DIVISION XV MECHANICAL 1 500 PROTECTION 5 FIRE R 1. FIRE PROTECTION SYSTEM PER BUILDING STANDARD AND LOCAL REGULATIONS AND ORDINANCES: 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS -WITH DISABILITIES ACT. - 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A-10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -TYPE S EEZE-TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE, PRESSURE GAUGE. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED IN PER BUILDING STANDARD REQUIREMENTS, UON. 6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT LOCATION` AND SIZE OF SPRINKLER LINES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 15800 - HEATING VENTILATING AND AIR CONDITIONING BUILDING STANDARD HVAC SYSTEMWITH ALL MATERIALS,LABOR AND ACCESSORIES 1: PROVIDE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS FOR COMPLETEREQUIRED. 2. DESIGN OF MECHANICAL TO BE PREPARED UNDER A SEPARATE PERMIT. 3. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 4. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTSTOTO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 5. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS. 12 otb5 DIVISION XVI - ELECTRICAL 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. 2. PROVIDE ALL WORK EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ALE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PERPOWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION U CATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION IGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUDRINGS TO BE LOCATED AT 15" AFF TO THE CENTER LINE, UON. , 5.WHERE MULTIPLE DEVISES OCCUR INLOCATIONS, A SINGLE OC TIONS ALL DEVICES BE GANGED UON. 6. GFI CIRCUITS TO BE LOCATED 24" FROM FAUCET CENTERLINE, PER CODE. 7. ALL WIRING DEVICES.. SHALL BE BUILDINGSTANDARD S A DARD EXCEPT.:..ISOLATED GROUND" .OUTLETS", SHALL BE ORANGE,"HOSPITALRAD G E ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A ,.:..GREEN DOT "EMERGENCY" OUTLETS SHALL BE RED, AND"DEDICATED" "CLEAN FOR CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVERPLATES SHALL BE BUILDING STANDARD F A FINISH,` UON. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, COMPUTERS, ETC.) WHEN NOTED O ON THE CONSTRUCTION DOCUMENTS. 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING,AND CONDUIT SHALL BE CONCEALED IN FLOORS, L RS WALLS, OR CEILINGS. CABLING VOICE AND N DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. M AGE . 11. THE�NTR CO ACTOR IS TOCOORDINATE WITH THEWNE SUPPLIED R SUP LIED FURNITURE. SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND. WALL MOUNTED OU TED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENTFLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING SHALL BE INDICATED C ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES. 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL -APPLICABLE CODES:., -- 15. DRAWINGS INDICATE C E ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL, O AND COMMUNICATION COVERPLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK-TO-BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED.` 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN/BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN/BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION NDICAT AND RELATIONSHIP OF DEVICES. E ICES: COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER/DATA & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER/DATA DEVICES AND LIGHT GH FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR PROVIDE O E INSTALLATION DESIGN DOCUMENTS TO ARCHITECT CH CT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 16500 -LIGHTING: 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL. BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST HANDICAPPED CODES AND REGULATIONS: 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 3. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEILING TILE; UON: 4. REUSE ALL EXISTING B/S FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO. MEET LOCAL ENERGY CODE COMPLIANCE. 5. DESIGN OF ELECTRICAL TO BE PREPARED UNDER A SEPARATE PERMIT AS A DESIGN BUILD PROJECT: PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 6. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING -HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 7. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT: C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. D. LIGHT FIXTURE SPECIFICATIONS 8. CONTRACTOR PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. R' EWED FOR COD ; * MPLIANCE PROVED RECEIVED CITY OF TUKWILA DEC 0 4 2013 ofTukwita RU) ► NG DIVISION NOV 15 2013 PERMIT CENTER SABEY SABEY ARCHITECTURE seattle, washington 206.281.8700 sabey.00m 6194 KARA M. REGISTERED CHI ECT ASSN STATE OF WASHINGTON COMMON IMPROVEMENT: BUILDING 5 NORTHWEST ENTRY NTRY MODIFICATIONS FIRST FLOOR ooR inter9 at e. A TECHNOLOGY GANPIJB 3411 South 120th. Place Tukwila, WA 10/17/13. BUILDING PERMIT MARK DATE DESCRIPTION ISSUE: PROGRESS DATE: DRAWN BY: CHECKED BY: APPROVED BY: 10.17.13 BH SS PROJECT NO: FILE: 12-0702 IGE-5 NwBallIstIc All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. ZONING; MMC/H MANUFACTURING / INDUSTRIAL CENTER HEAVY AND LIGHT AREA: 48. 20388 ACRES Ill inr vvyv.•ncr�.e=rxZ�.�:�. BUILDING AREA: BUILDING 1 BUILDING 2 BUILDING 3 BUILDING 4 98,564 S.F. 107,489 S.F. 201,360 S.F. 115,010 S.F. BUILDING 5 " 217,355 S.F. BUILDING 6 5,352 S.F. TOTAL AREA: SEISMIC ZONE: 3 PARKING REQUIRED: OFFICE: MANUFACTURING: WAREHOUSE: SABEY ARCHITECTURE seattle, washington 206.281.8700 sabey,com 33,226 S.F. X 2.5 /1,000 88 STALLS 551,142 S.F. X 1 /1000 561 STALLS 154,179 S.F. X 1 /2000 77 STALLS BUILDING 1 TOTAL REQUIRED: utu:1L'.L.. .... �.. PARCEL NUMBER: 102304-9082 LEGAL DESCRIPTION: PARCEL D (BUILDING 21-05) LOT 5, BOUNDARY LINE ADJUSTMENT NO. L02-057, RECORDED UNDER RECORDING NO. 20030327900002, AS AMENDED BY RECORDING NO. 20030725001852, RECORDS OF. KING COUNTY, WASHINGTON. REGISTERED RCECT IFt 10 1�. KARA M. A 'SON STATE OF WASHINGTON COMMON IMPROVEMENT:: BUILDING 5 NORTHWEST ENTRY MODIFICATIONS FIRST FLOOR 3411 South 120th. Place Tukwila, WA BUILDING 5 10/17/13 BUILDING PERMIT MARK I DATE DESCRIPTION ISSUE: PROGRESS DATE: DRAWN BY: BH CHECKED BY: SS APPROVED BY: PROJECT NO: FILE: 12-0702 IGE-5 NwBaliistIc INTERGATE.EAST SITE PLAN 0 25' 50' 100' REVIEWED FOR CODE COMPLIANCE APPROVED DEC 042013 Cityof Tukwila BUILDING DIVISION All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation. SITE PLAN RECEIVED CITY, OF TUKWILA NOV 1 5 2013 PERMIT CENTER cc - _ ' i $ ,UP 1111 DEMOLITION PLAN O. SCALE: 1/8" = 1'-0" KEY NOTES: 0 10 11 12 0 • CO L� EXISTING EXIT EXISTING - EXIT DOOR UP 4 CONSTRUCTION PLAN SCALE: 1/8" = 1'-0" DEMOLISH EXISTING WALLS AND MAN TRAP DOORS MAKE GOOD FLOOR AFTER DEMO POUR NEW CONCRETE TO FILL RECES INFILL OPENING WITH NEW WALL TO MATCH EXISTING- BALLISTIC PROOF WALL NEW WALLS TO UNDERSIDE OF ACOUSTIC CEILING TILE - APPROX. 10' HIGH PRO VIDE HAND SCANNERS FOR ACCESS INTO SECURITY VESTIBULE PROVIDE HAND SCANNERS FOR ACCESS INTO BUILDING PROVIDE CARD READERS FOR ACCESS OUT OF BUILDING DOOR SEQUENCING: IN FRONT OF "A DOORS PROVIDE HAND SCANNERS, WHEN ACTIVATED DOOR . WILL UNLOCK AND ALLOW PERSON TO MANUALLY OPEN AND ENTER THE VESTIBULE. IN FRONT OF "B" DOORSR PROVIDE OVIDE HAND SCANNERS. WHEN ACTIVATED DOOR WILL UNLOCK AND ALLOW PERSON TO MANUALLY OPEN AND ENTER THE BUILDING. BOTH DOORS MUST BE SHUT BEFORE A DOOR WILL RELEASE AND ONLY ONE DOOR WILL RELEASE AT A TIME. THE DOOR SEQUENCING FUNCTIONS ARE FOR SECURITY PURPOSES AND EXISTING EQUIPMENT WILL BE REUSED. IN THE EVENT OF A POWER OUTAGE, "A" DOORS WILL FAIL IN THE CLOSED POSITION. PROVIDE EMERGENCY PANIC HARDWARE TO OPEN"A" DOORS, IN CASE OF EMERGENCY. REUSE EXISTING INTERCOM NEW GWB HARD LID CEILING - 9'-0" HIGH NEW FLORESCENT LIGHT FIXTURES NEW SECURITY CAMERAS, T -DAR SYSTEM • I LH • UP 11 O REF. CEILING. PLAN 0 SCALE: 1/8" = 1'-0" STRUCTURE ❑. FINISH SPECIFICATIONS SECURITY (NOT INCLUDED) Et (c PT - 1 ( CPT -1) m P UP '11 STAIR (NOT INCLUDED) FINISH PLAN SCALE: 1/8" =1'-O" +:; + + ,++ ++ + PRICIE+DPTIDNF TO+ DEMOLISH EXISTING+ - �VG�T+IN iCORRIDQI, + GRINDI- AND SEAL+. _ tON1CREEtE- bENEAfI1. APPROXI 750 SF + SYMBOL MANUFACTURER PRODUCT COLOR DESCRIPTION CPT -1 MILIKEN CONTRACT PASTE UP, NEGOTIATOR 418 BLACK BOOK FIELD CARPET CPT -2 INTERFACE FLOR SUPERFLOR 609158 KINGFISHER ACCENT. CARPET RB -1 T.B.D. 4" COVED / STRAIGHT T.B.D. ALL WALLS P-1 SHERWIN-WILLIAMS EGGSHELL FINISH 7053 ADAPTIVE SHADE FIELD PAINT P-2 WILLIAMS SHERWIN-WILLIAMS I N.. EGGSHELL FINISH . Lri 7047 PORPOISE ACCENT PAINT P-3 SHERWIN-WILLIAMS EGGSHELL FINISH 6705 HIGH STRUNG ACCENT PAINT EXISTING ACOUSTIC CEILING GRID NEW HARD LID ,S 5 0 T.O. DOOR x CO GWB CEILING WALL TYPE: INSULATE WHERE NOTED VESTIBULE DETAIL 0 2" SCALE: 1 1/2" = 1'-O" EXISTING BALLISTIC WALL 5/8" GWB EACH SIDE -JOINT COMPOUND -48" H x 96" W x 7/16" THICK UL -752 LEVEL 3 BULLET RESISTANT FIBERGLASS SHEETS (BULLET GUARD) BOTTOM TRACK WITH POWER DRIVEN ATTACHMENT CONCRETE SLAB 16" • REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 4 2013 City of Tukwila BUILDING DIVISION SYMBOLS LEGEND: EXISTING CONSTRUCTION TO REMAIN EXISTING CONSTRUCTION TO BE REMOVED NEW CONSTRUCTION CEILING LEGEND NEW 6"x48" FLUORESCENT FIXTURE NEW SECURITY CAMERA NEW GWB HARDLID CEILING GENERAL DEMOLITION NOTES: 1. REFER TO CONSTRUCTION PLAN AND CEILING PLAN FOR EXTENT OF DEMOLITION. 2. SAVE AND STORE ALL LIGHT FIXTURES, EXIT SIGNS, DOORS AND HARDWARE FOR REUSE, UON. 3. REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTLETS, FIXTURES, PANELS, ETC. FROM ALL DEMOLISHED PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO ORIGINATING SOURCE, UON. GENERAL CONSTRUCTION NOTES: 1. REFER TO PROJECT NOTES FOR CONSTRUCTION. REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTITION RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL/CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PARTITIONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR. BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES . '. MOUNTED ON OR ATTACHED TO. PARTITIONS. 6. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE-RETARDENT TREATED WOOD. 7. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 4" FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. 8. REPAIR EXISTING WALLS AS REQUIRED. 9. VERIFY ALL SECURITY AND LOW VOLTAGE VOICE DATA WITH BUILDING MANAGEMENT. 10. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDITIONAL P/P/D MAY EXIST BUT NOT BE REFLECTED ON THE PLANS. -GENERAL-RCP-NOTES: 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE TYPE AND LOCATION OF. LIGHT FIXTURES REFER TO DESIGN BUILD ELECTRICAL DRAWINGS AND DESIGN BUILD LIFE SAFETY FOR COMPLETE REFLECTED CEILING PLAN DESIGN. 3. LIGHT SWITCHES AREH WN FOR O LOCATION AND DESIGN INTENT ONLY. REFER TO ELECTRICAL DESIGN BUILD FOR SPECIFIC LOCATION AND SWITCHING DIAGRAMS. 4. UNLESSNOTED O TE D OTHERWISE, MULTIPLE .,.WITCH I S IN A SINGLE LOCATION O SHALL BE GANGED IN A SINGLE. BOX AND COVERED WITH A SINGLE COVERPLATE 5. CLEAN REPAIR OR REPLACE AS REQUIRED Q D ALL EXISTING SUSPENDED CEILING GRID AND TILES EXISTING. TO REMAIN: 6. HVAC CONTRACTOR TO CLEAN ALL EXISTING SUPPLY/RETURN GRILLS PRIOR TO COMPLETION OF. PROJECT. 7. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR CONFIRMING THE COUNTS OF EXISTING FIXTURES. GENERAL DOOR & HARDWARE NOTES: 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME @ HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH BOLTS. 5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC & ACCESSIBILITY REQUIREMENTS. DOOR SCHEDULE: w 0 0 0 DOOR w RATING (MIN) RECEIVED CITY OF TUKWILA NOV 1 5 2013 PERMIT CENTER 100A 100B 101A 101B 3'-0" 8'-0" A 1 HM NR 3'-0" 8'-0 2 HM NR 3'-0" 8'-0" A 1 HM NR 3'-0" 8'-0" B 2 HM NR BALLISTIC DOOR, PAINT TO MAIrCH EXISTING.' DOOR TO BE PAINTED TO MATCH EXISTING, BALLISTIC DOOR, PAINT TO MATCH EXISTING. DOOR TO BE PAINTED TO MATCH EXISTING. HARDWARE GROUP: HARDWARE GROUP GROUP 1 SINGLE, NON -RATED HARDWARE NOTES 1 ENTRY FUNCTION MAGNETIC LOCKSET, POWER OPERATED 1.5 PAIR HINGES 1 EXIT BAR, PANIC HARDWARE CONTROLLED BY HAND SCANNER AT ENTRY GROUP2 SINGLE, NON -RATED 1 ENTRY FUNCTION MAGNETIC LOCKSET, POWER OPERATED 1,5 PAIR HINGES CONTROLLED BY HAND SCANNER AT VESTIBULE AND CARD READER FROM BUILDING DOOR TYPE A CD w • ' WIDTHt' PAINTED HOLLOW METAL FRAME BALLISTIC GLASS PAINTED PANEL HOLLOW METAL DOOR MATCH ALL EXISTING 'CONDITIONS DOOR TYPE B CD CU _ PAINTED HOLLOW METAL FRAME GLASS WIDTH' PAINTED PANEL HOLLOW METAL DOOR MATCH. ALL EXISTING CONDITIONS S.freE3 EN' SABEY ARCHITECTURE seattle, washington 206.281,8700 sabey.com 6194 " 1 i REGISTERED. AR IT T it ,/ KARA M. AND ` is STATE OF WASHINGTON COMMON IMPROVEMENT: BUILDING NORTHWEST T_ S ENTRY MODIFICATIONS N O S FIRST FLOOR Thiergate.east A TECHNOLOGY.. 3411 South 120th. Place .Tukwila, WA 10/17/13 BUILDING PERMIT MARK I DATE I DESCRIPTION ISSUE: PROGRESS DATE:. 10.17.13 DRAWN BY: BH CHECKED BY: SS APPROVED BY: PROJECT NO: FILE: 12-0702_1 G E-5_NwB a l l I stic All drawings and written material appearing herein constitute the original and unpublished work of the Sabey Corporation and the same may not be duplicated, used or disclosed without the written consent of the Sabey Corporation.