HomeMy WebLinkAboutPermit D13-046 - ROSS RESIDENCE - REMODELROSS RESIDENCE
12253 47 AV S
D13-046
City oii'ukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-43 1-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
Parcel No.: 0179001025
Address: 12253 47 AV S TUKW
Suite No:
Project Name: ROSS RESIDENCE
DEVELOPMENT PERMIT
Permit Number: D13-046
Issue Date: 07/12/2013
Permit Expires On: 01/08/2014
Owner:
Name: ROSS ROSE MARIE
Address: 12253 47TH AVE S , SEATTLE WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Contractor:
Name: CADENCE CONSTRUCTION INC
Address: 5821 S FLETCHER ST , SEATTLE WA 98118
Contractor License No: CADENCI915JB
Lender:
Name: KING COUNTY
Address:
Phone: 206-296-7437
Phone: 206-355-8340
Expiration Date: 04/05/2015
DESCRIPTION OF WORK:
THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE
ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK,
VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT).
Value of Construction: $21,037.00 Fees Collected: $842.70
Type of Fire Protection: NONE International Building Code Edition: 2009
Type of Construction: V -B Occupancy per IBC: 0022
Electrical Service Provided by: SEATTLE CITY LIGHT
**continued on next page**
doc: IBC -7/10
D13-046 Printed: 07-12-2013
Public Works Activities:
Channelization / Striping: N
Curb Cut / Access / Sidewalk / CSS: N
Fire Loop Hydrant:
Flood Control Zone:
Hauling: N Start Time: End Time:
Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y.
Landscape Irrigation:
Moving Oversize Load: Start Time: End Time:
N Number: 0
Size (Inches): 0
Sanitary Side Sewer:
Sewer Main Extension: Private: Public:
Storm Drainage:
Street Use: Profit: N Non -Profit: N
Water Main Extension:
Water Meter: N
Permit Center Authorized Signature:
LoO,
Private: Public:
Date: -7‘. 13-13
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of t
construction or.t
to this permit.
Signature:
rmit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
rformance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached
Print Name: . J`^0
Date:
t z- (3
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
doc: IBC -7/10
D13-046 Printed: 07-12-2013
this requirement.
• •
7: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be
obtained at City Hall in the office of the City Clerk.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IBC -7/10
D13-046 Printed: 07-12-2013
CITY OF TUKWILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.ci.tukwila.wa.us
Building Permit No.
Mechanical Permit No.
Plumbing/Gas Permit No.
Public Works Permit No.
Project No.
(For office use only)
(p
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 12253 47th Ave S.
Tenant Name: Rose Ross
Property Owners Name: Rose Ross
King Co Assessor's Tax No.: 0179001025
Suite Number: Floor:
New Tenant: 0 Yes ® ..No
Mailing Address: 12253 47th Ave. S.
Tukwila
WA
98178
City
State
Zip
CONTACT PERSON - who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
Day Telephone: (206) 296-7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACTOR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5))
Company Name: not yet awarded
Mailing Address:
Zip
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
Expiration Date:
State
ARCHITECT OF RECORD - All plans must be wet stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Jesse Holgate or Timothy Fenlason
E -Mail Address: jesse@smstemper.com/tfenlason@jonespayne.cco
City State
Day Telephone:' (206) 624-2777
Fax Number: (206) 624-2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H:\Applications\Forms-Applications On Line\2009 Applications\I-2009 - Permit Apptication.doc
Revised: 1-2009
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
• •
BUILDING PERMIT INFORMATION — 206-431-3670
Valuation of Project (contractor's bid price): $ 21,037 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers 0 Automatic Fire Alarm m None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Upplicanons\Fonns-Applications On Line\2009 Applications \I-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
151 Floor
1,025
2"d Floor
3`d Floor
Floors thru
Basement
1,090
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? 0 Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
0 Sprinklers 0 Automatic Fire Alarm m None 0 Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No
If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets.
SEPTIC SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:Upplicanons\Fonns-Applications On Line\2009 Applications \I-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
PERMIT APPLICATION NOTES — Applicable to all .permits in this application
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER 0 • . ldit
Signature: /�r _ Date: Z/L/i3
Print Name: Tim•,i Fenlason, SM Stemper Architects, PLLC Day Telephone: (206) 624-2777
Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106
Zip
City
State
Date Application Accepted:
Date Application Expires:
Staff Initials:
H:Wpplicattons\Forns-Apphcanons On Line\2009 Apphcanons\1-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 6 of 6
City oukwilar
Department 'df Community Development
6300 Southcenter Boulevard, Suite #I00
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: hiip:/tvww.ci.tukwila.wa.us
SET RECEIPT
•
Copy Reprinted on 02-19-2013 at 09:09:21 02/19/2013
RECEIPT NO: R13-00837
Initials: WER
Payment Date: 02/19/2013
User ID: 1655 Total Payment: 5,833.28
Payee: PAMELA K KUEHL (BY PHONE)
SET ID: 020713 SET NAME: KING COUNTY SOUND ABATEMENT
SET TRANSACTIONS:
Set Member Amount
D13-045 811.18
D13-046 842.70
D13-047 716.64
D13-048 748.15
D13-049 622.10
D13-050 1,067.51
M13-038 167.70
M13-039 167.70
M13-040 167.70
M13-041 167.70
M13-042 167.70
M13-043 186.50
TOTAL: -mfr :SAF
TRANSACTION LIST:
Type Method Description . Amount
Payment Credit C VISA 5,833.28
TOTAL: 5,833.28
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES 000.322.100 2,897.75
MECHANICAL - RES 000.322.102.00.0 1,025.00
PLAN CHECK - RES 000.345.830 1,883.53
STATE BUILDING SURCHARGE 640.237.114 .--.2/7-0-0
TOTAL:
LTi!`?^
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT N0.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Pr4jecOts� c S
CO G CII 2 /NJ 4 - ii-pp/Nei
Typegf Inspection:
Address:
I1153 LI7
PwS
Date Called:
Special Instructions:
Date�V,�antedi 3 - 1 a:m:
�� m.
Requester:
Phone No:
,I.)G— L/99 -02752_
EjApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
CO G CII 2 /NJ 4 - ii-pp/Nei
@ QDaf(t','(i N.,5 :� NSift— 4p.iv
_/et, 1 (%.r• .? / 1e 1r.�.,4/
7
1 pe
1
Dates
7-�3
SPECTION FEE R UIRED. Priof to next inspection. fee must be
d at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
07-01-2013
410
City of Tukwila
Jim Haggerton, Mayor
Department of Community Development Jack Pace, Director
SHARYN PARKER
7277 PERIMETER RD S
SEATTLE WA 98108
RE: Permit Application No. D13-046
ROSS RESIDENCE
12253 47 AV S TUKW
Dear Permit Applicant:
In reviewing our current application files, it appears that your permit applied for on 02/07/2013, has not been
issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code,
Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days
from the date of application shall expire and become null and void. Your permit application will expire on
08/06/2013.
If you still plan to pursue your project, a written request for extension of your application must be submitted to the
Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building
Official and state your reason(s) for the need to extend your permit application. If it is determined that an
extension is granted, your application will be extended for an addtional 90 days from the expiration date and you
will be notified by mail.
In the event that we do not receive your written request for extension or request was denied, your permit
application will expire, become null and void and your project will require a new permit application, plans and
specifications, and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
e
Bill Rambo
Permit Technician
. File: Permit File No. D13-046
6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
,Eil+NT
,�� • exp
COC:.
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-046 DATE: 02-07-13
PROJECT NAME: ROSS RESIDENCE
SITE ADDRESS: 12253 47 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # After Permit Issued
EPARTMENTS:ta_ 1�
u li ding Division up
Public Works
Fire Prevention
Planning Division
n
Structural ❑ Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete
DUE DATE: 02-12-13
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route tg Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 03-12-13
Approved ❑ Approved with ConditionsNI- Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS: DATE:
Permit Center Use Only,.
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Documents/routing slip.doc
2-28-02
Contractors or Tradespeople Per Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name CADENCE CONSTRUCTION INC UBI No. 602882989
Phone 2063558340 Status Active
Address 5821 S. Fletcher Street License No. CADENCI915JB
Suite/Apt. License Type Construction Contractor
City Seattle Effective Date 4/2/2009
State WA Expiration Date 4/5/2015
Zip 98118 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
CADENC•971K2
CADENCE
CONSTRUCTION
Construction
Contractor
General
Unused
5/22/2003
8/9/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
NISSINEN, KIMMO JOACHIM
President
04/02/2009
Amount
KELLEY, KATHRINE (KATIE) ANN
Vice President
04/02/2009
IG011001726
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
DEVELOPERS SURETY
& INDEM CO
799434C
03/18/2009
Until Cancelled
$12,000.00
04/02/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
5
INTERNATIONAL
INS CO OF
HANNOV
IG011001726
03/07/2013
03/07/2014
$1,000,000.00
03/13/2013
4
Starr Surplus
Lines Insurance
SLPG GL10524
00
06/06/2012
11/26/2013
03/13/2013
$1,000,000.0011/20/2012
3
Berkley
Regional Ins Co
CGL0007586
22
11/26/2011
11/26/2012
$1,000,000.0011/04/2011
2
BERKLEY
REGIONAL
SPECIALTY INS
CGL000758622
11/26/2010
11/26/2011
$1,000,000.0011/03/2010
1
BERKELY
REGIONAL
SPECIALTY INS
CGL000758622
11/26/2008
11/26/2010
$1,000,000.0010/27/2009
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
07/12/2013
KING COUNTY INT
ERNATIONAL AIRPORT
RESIDENTIAL AIRCRAFT NOISE REMEDY IMPROVEMENTS PROGRAM - C00783C12 BID PACKAGE S-36
3-53-0058-045
SCOPE OF WORK
RENOVATION a RESIDENCE TO REDUCE NOISE INFILTRATION OF AIRCRAFT NOISE AND PROVIDE
MECHANICAL vENTLATION. THE CONMACT INCLUDES ALL. INFORMATION IN THE DRAWINGS AND
SPECIFICATIONS INCLUDING BUT NOT LIMITED To:
APPLICABLE
YES NO
1 SELECTIVE REPLACEMENT OF EXISTING WINDOWS WINNEW vINYL-FRMED ACOUSTICAL WINDOWS.
X
2. CUT 001114 a WINDOWS TO COMPLY WITH EGRESS REQUIREMENTS.
X
3. INFILL CF EASTING OPENINGS.
X
4 SEI_ECTrVE REPLACEMENT OP NTERIOR / EXTERIOR DOORS WITH NEW ACOUSTICAL DOORS.
X
5. INSTALLATION OF STORM DOORS.
X
6_ INSTALLATION OF SECONDARY 91_IDING GLASS DOOR&
X
1. INSTALLATION Cf SECONDARY SKYLIGHTS.
X
a INSTALLATION OF PET DOORS.
X
S. INSTALLATION OF FIREPLACE FRESH AIR vENT.
X
10. INSTALLATION OF cHltitslET CAP.
X
11. REGULATED MATERIALS ABATEMENT.
X
12. ATTIC VENT BAFFLES.
X
13. INSTALLATION OF ATTIC INSULATION.
X
14 INSTALLATION OP MECHANICAL VENTILATION ECUIFMENT. BLENDING AIR UNIT AND
ASSOCIATED DUCTING.
X
15. INSTALLATION OP MECHANICAL velca_ArioN EQUIMENT, FURNACE MODIFICATION AND
ASSOCIATED DUCTING,
X
16. ARCHITECTURAL MODIFICATIONS TO SUPPORT INSTALLATION CF MECHANICAL VENTILATICIst
X
11. ELECTRICAL MODIFICATIONS TO SUPPORT INSTALLATION OF MECHANICAL VENTILATION AND
ARcAITECTURAL MODIFICATIONS.
X
15 INSTALLATION OF SMOKE DETECTORS.
X
19. NEW ELECTRICAL- PANEL / SERVICE
X
20, KNOB AND TUBE LIARNG.
X
FILI COPY
Permft No. LAS"' Q44
r.-k-rvy approval is subject to errors and omissions,
of construction documents does not &Adze
ol nny adopted code or ordinance. Raceipt
y and conciliar* Is acieuvledged
City Of Tkikwila
BUILDING DIVISION
o
By
Date:
SION
chempes shaii rnade to tha scope
ot without prior'approval of
Tuf<tA4la Building Division.
-": r mquire a nv.v plan submittal
rrz.7 ins'Jdo. add:time! plan rc.iview fecs.
S PP);\ PERMIT
REQUIRED FOR:
EKechanical
[electrical
Oillumbing
4e -es Piping
rq of Tukwila
SITE AND BUILDING INFORMATION
JURISDICTION:
Department at planning and Development
City of Seattle, WA
AFF'LICABLE CODES:
2003 International Residential Code,
International Fire Code,
International Mechanical Code
0115001025
LEGAL DESCIRIFTICN:
LOT 21 TO 30, INCLUSIVE, BLOCK 5, ALLENTOWN ADDITION TO CITY OF SEATTLE, ACCORDING TO THE FLAT FIECORDED
N VOLUME 12 OF FLATS, PAGE 100, IN KING COUNTY, WASI4INGT0N.
ZONING: 5F1200
OCCUPANCY: (No Change/
SINGLE FAMILY RESIDENCE
CONSTRUCTION rrrE: (No Chang.st)
v 5 NON SFRINKLERED
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 1 4 „.,,
City of Tukwila
BUILDING DIVISION
DRAWING INDEX
T00 TITLE SWEET, PROJECT NFO,
A10 FLOOR FLANS 1 NOTES
A2.0 WINDOW TYPES, SCHEDULE 4 DETAILS
AV DOOR TYPES, SCHEDULE 4 DETAILS
A22 MISCELLANEOUS DETAILS
423 WINDOW FLASHING DETAILS
MI.0 LEGENDS, SCI-EDULES, ARV, GENERAL NOTES .4 DU. INDEX
M2.0 MECHANICAL FLANS AND DETAILS
EID E1 -ECTAL FLOOR PLANS AND NOTES
PROJECT DIRECTORY
KING COUNTY INTL. AIRPORT:
Sound Insulation Program
King County International Airport
12-1-1 Perimeter Road South
Seattle WA 58108
Ph: 206. 263. 9233
Fax: 206. 256. 0150
Contact: Sharyn Parker
E -ma SharynParkerektogeountygov
ARCHITECT!
S.M. Stever Architects
4000 Delridge Way SW, Suite 200
Seattle., WA 50106
Fh 206. 624. 2111
Fax: 206.624. 2913
LCal:Bungta;mtijeaiorld7joar°6sicrnatempeilissteaffipert.:41:corn
ACOUSTICAL ENGUNIEER
SSA Acoustics
222 Etruria Street, Suite 100
Seattle ILIA 50109
Fru 206. 839. 0515
Fax 206. 535. 0524
CoiUct Mohamed Alt Allacua
E-mail: mohamedossaacoustics.com
MECHANICAL ENGINEER
The ereenbusch Group
1500 West Nickerson St, Suite 201
Seattle, WA 95119
Fh 206. 313. 0565
Fax: 206. 315. 0641
Contact: Dylan Turner
pylanTigneembuschcom
ELECTRICAL ENGINEER:
Tres West Engineers
2102 6.42nd Street, Suite 301
Tacoma, WA 98409
Fh t 253. 412. 3300
Fax 253. 412. 3463
Contact: Brent Rollins
E -ma ib bamtresuuset.coin
REGULATED MATERIALS:
PBS Engineering and Environmental
2511 Eastlake Ave. E,, Suite 100
Seattle, WA 58102
Ph 206. 732. 5635
Fax: 206.162. 41E0
Contact: Tim Ogden
tim ogdenspletenv.com
DESIGN SUPPORT SERVICES
The Jones Payne Group
123 North Washington St. .200
Boston, MA 02I14
Contact: Tim Fenlason,
Cynthia Maeda
E-mail: tfolasoneJorespagne.c.om
CMaeciamijonespaynacom
STRUCTURAL- ENGINEER:
Peterson Strehle Martinson
2200 6th Ave, Suite 201
Seattle, WA 55121
Ph 206. 622. 4550
Pax: 206. 622. 0422
Contact: Ron Martinson
rommlopoin-englneel.com
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
VICINITY MAP (NTS)
• • '' .
' ' ....
. : .. ...... ",:'
** S .12fat. St
S.MSTEMPER
ARCHITECTS
A Prafesskaial Limite,1 Ltahility Carapany
4000 DELR1DGE WAY SW
surrE 200' SEATTLE, WA 98106
(200 824-27/7 • FAX (206) 024-2072
OCTOBER 19, 2012
0810.03.2328
1-
0
CL
0
z
ce1-
z
0
0z
MPROVEMENTS
AIP NUMBER
3-63-0058-045
0
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
jo
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
PROJECT
INFORMATION,
DRAWI NG
INDEX,
DIRECTORY
TO.0
0810.03.2328
SPECIAL NOTES:
I. ASBESTOS coNTAMING MATERIALS ARE PRESENT AT THIS RESIDENCE.
TI4E CONTRACTOR R MOVNG ACM SMALL REVIEW TIME EXECUTIVE
SUMMARYREPORT AND LAB ANALYSIS FOR EACI-F RESIDENCE INDICATED
TO 14AVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE
RESPONSIBLE FOR OvERSEEING ABATEMENT PROCEDURES. THE
CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS
E SQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 62 00 FOR
I ECs11LATED MATERIALS ABATEMENT.
2. LEAD PAINT 18 PRESENT AT THIS RESIDENCE. REFER TO SECTION 01 1101
AND 02 83 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
3. T I4IS RESIDENCE HAS EXISTING WIDE TRIM. NEW TRIM TO MATCI4 EXISTI14
REFERENCE 546/A22 FOR PHOTO.
4. REFERENCE 1/A22 PoR SMOKE/ CARsoN MONOXIDE DETECTOR
INSTALLATION DETAIL.
CRAWL
SPACE
FLIR
STORAGE
LOWER FLOOR PLAN
1/4" = 1' - On
PRIOR TO COMMENCING WITH DEMOLITION
A "pre -demo inspection" is required.
Contractors shall provide documentation that
an "asbestos survey" has been completed. If
needed, abatement procedures per "Puget
Sound Clean Air Agency" shall be completed
and documentation of compliance shall be
provided at time of final inspection.
GENERAL NOTES
L CONTRACTOR TO PROTECT OUJNERS' FURNITURE AND POS6E581ONS FROM DAMAGE AND DUST.
2. CONTRACTOR To TEMPORARILY REMovE FURNITURE, CONTE=NTS, WALL HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE= THE WORK OF
THESE DOCUMENTS AND RETURN THEM TO THEIR IGINA OCATIONS AT T COMPLETION OF WORT( PAI T.
L L HE L
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 PM TO 8:00 AM EACH
DAY. HOMEOWNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS IN THE RESIDENCE: FOR WEEKENDS.
4. SALVAGE, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS IN ALL ROOME>
S. D0ORS OR WINDOWS SCHEDULED TO BE REPLACED SHALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW 15 ON SITE, REMOVAL
AND 1REPL 4CEMENT OF A DOOR AND/OR WINDOW MUST OCCUR ON THE SAME DAY BETWEEN &.00 AM AND 5:00 PM.
6. DO NOT INSTALL NEUJ DOORS OR WINDOWS WHERE EXISTING WINDOW AND DOOR ROUGH OPENNGS ARE: DETERIORATING., (EEE: WOOD ROT,
TERMITE DAMAGE) CONTACt TECI-INICAL REFRESENTATIvE 1F pETERIoRATioN IS UNcovERED.
T. ADD SOLID WOOD BLOCKING AT WINDOWl18.
S. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOW FLASHING DETAILS 51-IEET FOR WINDOW REPLACEMENT.
B. EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS GONPLETION OF WINDOW INSTALL. IF WINDOW COVERINGS ARE
NOT AvAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST ISE PROVIDED.
I0. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW' TYPE SCHEDULE.
11. ALL WORK AREAS SHALL ESE BROOM -CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/ORMECH. COMPONENTS INTEWERE WITH (E) CLOSET SHELVING, DEMO (E) 51-1ELVING A5 REQ'D AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH 50FFITS AND/OR MECHANICAL COMPONENTS RECONSTRUCT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FINISH AS CLOSELY A5 POSSIELE TO EXISTING. RECONSTRUCT SHELVING 50 As NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS HATCHES:
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTJRE3ED ST THE WORK PATCH RISTUR SED AREA TC MATCH (E) TEXTURE AND COLOR. THERE ARE
SEVERAL GRADES OF TEXTURE AND DENSITY OF CECLING PLASTER FINISH COATS PRESENT AT VARIOUS LOCATIONS THROUGHOUT THE
PROJECT LOCATION. REPLACEMENT FINSH COAT SYSTEMS ARE TO MATCH TIME ADJACENT (E) FINIS COAT.
I. PANELS, DUCTS 4 SWITCHES ON ,ARCHITECTURAL DRAWINGS :ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
I. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
11. DEMOLISH ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND FINISH WALL AFTER WORK. REFER TO ELECTRICAL
FOR TIMER LOCATION
15. INSTALL SMOKE DETECTORS. SEE ARCHITECTURAL SHEET AIS FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTOR& SEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET,
12..- CONTRACTOR IS TO VERIFY THAT THERE ARE St.IFFiCIE NT INSTALLAT10N, JURISDICTIONAL, AND WORKING CLE=ARANCE° FOR THE MECHANICAL
EQUIPMENT, JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTROL PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FINISI-IES. COORDNATE WITH MECHANICAL.
20. MAXFUI Pt LER co.ititiE 18 EIGFIT Imo, PCS MUOT EE PR0MED AT RESIDENCE WORE &080 AM 1 AFTER PM.
A. EAST ELEVATION
DECK
Fr—
u
s
BEDROOM
1
E3ATN 1
DIN 1NG
ROOM
BEDROOM
2
24" x 48" EXIST
ATTIC ACCESS
PANEL
N
0
Ave
DECK
B. SOUTH ELEVATION
PLAN KEYNOTES
0 DEMOLISH (E) WINDOW, CASING AND TRIM. INSTALL ACOUSTICAL WINDOW ASSEMBLY. REF, WINDOW SCHEDULE,
(2) DEMOLISH EXISTN( DOO (5y FRAMCASING,TR M AND Ti -He, 5HOLD. INSTALL NEW EXTERIOR DOOR, FRAME CASING, TRIM, TI-RESHoLD AND
STORM' DOOR Rte. DOOR SCHE=DULE.
CINSTALL NEW SECONDARY SLIDING DOOR(51 REF. DOOR SCHEDULE.
.4 INSTALL VENT BAFFLES) AT EXISTING GABLE END VENTS) N ATTIC. REF_ 3/422 FOR DETAIL.
5 . DEMOLISH EXTERIOR WALL ASSEMBLY A5 REQUIRED: INSTALL FRESH AIR INTAKE GRILLE. REF. 1/42.2 FOR DETAIL. COORDINATE WITH
MECHANICAL DOCUMENTS.
0 INSTALL NEW THERMOSTAT: CCORINATE WITH MEC-ANICC AL DOCUMENTS.
PET DOORR' MANUFACTURES INET IONS
C) INSTALL NEW 10"X 21�Pf= � R11CT . REF. 4/422 FORrrDETAIL.
ACCESS TO SITE AND PARKING
1. TI4E CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PARK IN OR BLOCK ACCESS TO HOMEOWNER DR1VEWAr.
C. WEST ELEVATION
LEGEND
x
DOa
A
ACOUSTICAL WINDOW
REFER TO WNDOW SCHEDULE
ACOUSTICAL DOOR/ STORM DOOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO DOOR SCHEDULE
MECHANICAL GRILLE
(E) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE,
REFER TO MECH. FOR UNIT
PHOTO DETAIL
EXTERIOR ELEVATION PHOTO VIEW
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14 9811
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 072013
PERMIT CENTER
D. NORTH ELEVATION
D 13-0 ylo
111111111111
GABLE END VENT BAFFLE
ROOF VENT BAFLE
KITCHEN EXHAUST DAFFLE
FEATHER TEXTURED CEILING OVER AT A
1 MIN. OF 24° FROM" EDS OF PATCHING.
MATCH (E) TEXTURE AND PAINT
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND WHOLE 140U5E VENT INSTALLATION.
REF. MECH. # ELECT.
REF, GENERAL NOTE 11
ATTIC INSULATION
ATTIC INSULATION DAM
INSTALL BATTERY OPERATED SMOKE
DETECTORS
INSTALL BATTERY OPERATED SMOKE /
CARSON MONOXIDE DETECTORS
GAS METER:
SOFFIT FOR MECHANICAL. DUCTING;
S.M.STEMPER
ARCHITECTS
A Proteeaional<Limited Liability Company
4000 DELRIDG]' WAY SW
SUITE 200 • SEATTLE, Wk 98106
(20e) 624-2777 . FAX (206) 824-2979
OCTOBER 19, 2012
0810.032328
0
0
z
0
2
ce
w
0
0
z
MPROVEMENTS
w.
w
ce
w
0
LL
ce
I.1.1
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% C D
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&.CP
FLOOR
PLANS
NOTES
A1 .0
0810.03.2328
SPECIAL NOTES:
I. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.
THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE
SUMMARY REPORT AND LAB ANALYSIS EOR EACI4 RESIDENCE INDICATED
144vACM PRESENT FICOR TO START OF WOW AND WILL BE
RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES THE
CONTRACTOR SHALL IDENTIFY', 61UANTIFt, ANP LOCATE ALL AREAS
REQUIRING ABATEMENT. REFER TO SECTION 01 11 01 AND 02 82 00 FOR
REGULATED MIATERIA.LS ABATEMENT.
2. LEAD PANT 1$ PRESENT AT THIS RESIDENCE. REPER 70 SECTION 01 11 01
AND 02 &3 01 FOR REQUIREMENT RELATED TO EXTERIOR WINDOW TRIM
PAINT.
3. T1415 REsiDENcE HAS EXISTING WIDE TRIEL NEW TRIM 70 MATCH EXISTING.
REFERENCE 546/A2.2 FOR PHOTO.
4. RIEFERENCE 1/A2.2 FOR SMOKE/ CARBON MONOXIDE DETECTOR
INSTALLATION DETAIL.
GENERAL NOTES
1. CONTRACTOR TO PROTECT DINERS' FutesrugE AND POSSESSIONS FROM DAMAGE AND DUST.
2. callfeAcToR TO TEMPORARILY REMOVE FURNIThRE, CONTENTS, WALL- HANGINGS AND FIXTURES AS REQUIRED TO EXECUTE THE WORK. OE
THESE DOCUMENTS AND TRETURN TI -IM TO THEIR ORIGNAL LOCATIONS AT 114E COMPLETION OP WORK DAILY.
3. HOMEOWNER SHALL HAVE COMPLETE ACCESS TO THE RESIDENCE AND TO EACH ROOM IN RESIDENCE FROM 5:00 191 TO 8:00 AM EACH
DAY. HOMEOUNERS WILL HAVE COMPLETE ACCESS TO THE RESIDENCE AND ROOMS 04 THE RESIDENCE FOR WEEKEND&
4. 5ALvA6E, PROTECT, AND REINSTALL EXISTING WINDOW COVERINGS N ALL ROOMS
S. DOORS OR WINDOWS SCHEDULED TO BE REPLACED S14ALL NOT BE REMOVED UNTIL REPLACEMENT DOOR OR WINDOW IS ON SITE. REMOVAL
AND REPLACEMENT Of A DOOR AND/OR WINDOW MST OCCUR ON THE SAME DAY BETWEEN &00 AM AND 5:00 PM.
6. D0 NOT NSTALL NEW DOORS OR ILINDOLUS WHERE ExisttNa ILAN:Doti AND c)0OR ROUGH OPENINGS ARE DETERIORATNG, (EG WOOD ROT,
MITE DAMAGE) CONTACT' TEC14NICAL REFREsro-Ative IP !DETERIORATION IS UNC.OVERE1D.
1. ADD SOLID WOOD BLOCKING AT UJNIDOWS,
8. FOLLOW WINDOW FLASHING INSTALLATION PROCEDURE ON WINDOUJ FLASHING DETAILS SHEET FOR WINDOW REPLACEMENT.
a EXISTING WINDOW COVERINGS MUST BE REINSTALLED ON THE SAME DAY AS COMPLETION OF WINDOW WALL. IF WINDOW COVERINGS ARE
NOT AVAILABLE, OR INSTALLATION AND/OR FINISHES ARE NOT COMPLETE, TEMPORARY WINDOW COVERINGS MUST BE FROYIDED.
10. INSTALL SAFETY GLAZING PER CODE. SEE WINDOW TYPE SCHEDULE
IL ALL WORK AREAS SHALL BE BR00M-CLEANED AT THE END OF EACH WORK DAY.
12. WHERE SOFFITS AND/OR MECH. COMPONENT'S INTERFERE WITH (E) CLOSET SHELVING, DEMO (E) SHELVING AS RECID AND RE -CONSTRUCT
SHELVING IN COORDINATION WITH SOFFITS ANP/OR MECHANICAL COMPONENTS. RECONSTR1CT SHELVING TO MATCH (E) CONFIGURATION,
MATERIALS, AND FNISH AS CLOSELY AS POSSIBLE TO EXISTING. RECONSTRUCT SI-ELVING 5045 NOT TO INTERFERE WITH THE OPERATION
OF MECHANICAL UNIT ACCESS 1-1ATCHES.
13. DIMENSIONS ARE FOR REFERENCE ONLY. FIELD VERIFY ALL DIMENSIONS AND CONDITIONS.
14. WHERE CEILING FINISHES ARE DISTURBED BY THE WORK, PATCH DISTURBED AREA TO MATCH (E) TEXTURE AND COLOR THERE ARE
SEVERAL GRADES OF TEXTURE ARD DENSITY OF CEILING PLASTER FINISH COATS FRESENT AT VARIOUS LOCATIONS TI-ROUGI4OUT THE
PROJECT LOCATION. REPLACEMENT FN161-1 COAT SYSTEMS ARE TO MATCH THE ADJACENT (E)FNIS14 COAT.
I. PANELS, DUCTS & SUATC14ES ON ARCHITECTURAL DRAWINGS ARE FOR COORDINATION ONLY. REF: ELECTRICAL AND MECHANICAL.
16. ALL CONDUITS, DUCTS AND MECHANICAL VENTILATION UNITS SHALL BE CONCEALED.
n. DEM01-1514 ISOLATED WALL AREAS TO FACILITATE INSTALLATION OF TIMERS. PATCH AND R'4FSH WALL AFTER WOW. REFER TO ELECTRICAI-
FOR TIMER LOCATION
IS. INSTALL smote DETEoToRs. SEE ARCHITECTURAL SWEET 410 FOR LOCATIONS OF BATTERY OPERATED SMOKE DETECTORS. BEE
ELECTRICAL SHEET E1.0 FOR LOCATIONS AND DETAILS OF INTERCONNECTED SMOKE DETECTORS. REFER TO SMOKE DETECTOR INSTALLATION
DETAIL ON MISCELLANEOUS DETAILS SHEET.
a CONTRACTOR IS TO VERIFY THAT TI -ERE ARE SUFFICIENT INSTALLATION, JURISDICTIONAL, AND woWiNa CLEARANCES FOR THE MECHANICAL
EQUIPMENT. JURISDICTIONAL CLEARANCE: 36" CLEAR IN FRONT OF CONTP..01- PANEL. INSTALLATION CLEARANCE: SUFFICIENT CLEARANCE
FOR WORK CREWS TO SAFELY INSTALL, MEET CLEARANCES, AND RESTORE FNISI-E5. COORDINATE WITH MECHANICAL.
20. MAXIMUM DOVER OUTAGE IS EIGHT 'OURS. MILER MUST OE PROVIDED AT RESIDENCE !IMRE 8100, AM 4 AFTER SOP FPI.
7
- -
3T-10"
-7
, 77.
. ... - - 7/
7
L
•
•
•
- • .
. .
•
•
•
/
-/ -
/
- -
e .
- /-
/4/
•
...
0
1
. .
I
1- — - - -
-Fr —
4
_
•• 24" x. 4S" EXIST.
• ATT1C ACCESS
111111111111
PANEL
• I -
•
•
•_ ....
•
•
//-
„A' - 7- ,-- -
. a. • a. . a
^ ..... .....
.....
•
• At
a a a a a
\ I
a I
431-10"
AY a
...
.....
.....
--
—J
. . .
•
-
A. EAST ELEVATION
B. SOUTH ELEVATION
PLAN KEYNOTES
0 DEMOLISH (E) WINDOW, CASNG AND TRIEL INSTALL ACOUSTICAL WINDOW ASSEMBLY. F. LUINDO.0 SCHEDULE,
THRESHOLD. INSTALL NEW ExTERIOR DOOR, FRAME, USING, TRIM, TI-RESHOLD AND
(74‘ ENGLISH ExISTINe 0001W4SFRAME, CASIN6, TRIM MDH
1 STOW( DOOR REP. DOOR 5C14ELDULE.
0 INSTALL NEW SECONDARY SLIDING DOORLS). REF. DOOR SCHEDULE.
0 INSTALL VENT BAFFLE(S) AT EXISTING GABLE END VENT(S) N ATTIC REF. 3/422 FOR DETAIL.
IR INTAKE LE. REF. 1/A2.2 FOR DETAIL. COORDNATE WITH
�DEMOLISH EXTERIOR WALL ASSEMBLY AS REQUIRED: INSTALL FRESH AGRL
MECHANICAL DOCUMENTS
INSTALL NEW THERMOSTAT: OOORDNATE WITH MEC.HANICAI_ DOCUMENTS.
0 INSTALL 14E11.1 10" X 21" PET DOOR FER MANUFACTURES iNsTRuoTioNs. REF. 41422 fOR DETAIL.
ACCESS TO SITE AND PARKING
1. T145 CONTRACTOR AND THEIR SUBCONTRACTORS SHALL NOT PAW 114 OR BLOCK ACCESS 10 WOMEOU,NER DRIVEWAY.
ATTIC PLAN
1/4"= 1' - 0"
C. WEST ELEVATION
LEGEND
0
ACOUSTICAL WINDOW
WINDOW SCI4EIDULE
REFER TO
ACOUSTICAL DOOR/ STORM POOR
REFER TO DOOR SCHEDULE
SECONDARY SLIDING GLASS STORM
DOOR REFER TO Dom SCHEDULE
MECHANICAL GRILLE
LE) KITCHEN EXHAUST
ELECTRICAL PANEL
FRESH AIR INTAKE GRILLE.
REFER TO MECH. FOR UNIT
PHOTO DETAIL.
EXTERIOR ELEVATION P1-10TO VIEW
REVIEWED FOR
'CODE COMPLIANCE
APPROVED
FEB 14 ,nj'
•
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
D. NORTH ELEVATION
111111111111
IMINIMM=1
1•1•11MINIMIN
■■■■■11111
CIAELE END VENT BAFFLE
ROP VENT BAFFLE
KITCHEN EXHAUST BAFFLE
FEATI-ER TEXTURED CEILING OVER AT A
7777 • 77(7 -71 MIN. OF 24" FROM EDGE OF FATC.4.4NG,
I MATCH (E)TEXTUIRE AND PAINT
Ins 1
ATTIC ACCESS PANEL
CEILING DEMOLITION FOR ATTIC PANEL
AND U.A4OLE HOUSE VENT INSTALLATION.
REF. MECEL 11 ELECT.
REF, GENERAL NOTE 11
ATTIC INSULATION
ATTIC INSULATION DAM
INSTALL BATTERY OPERATED smote
DETECTORS
(2) INSTALL BATTERY OPERATED SMOKE
CARBON MONOXIDE DETECTORS
'GAS
GAS METER
SOFFIT FOR MECHANICAL DUCTING
S.M STEMPER
ARCHITECTS
A PratessiOnal Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98100
(208) 824-2777 • FAX (208) 824-2072
OCTOBER 19, 2012
ce
0
cL.
ce
0
z
w
z
0
MPROVEMENTS
AIP NUIVIBER
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
J
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
FLOOR
PLANS
NOTES
A1.1
0810.03.2328
WINDOW TYPES
1.
DOUBLE -1G
2.
CASEMENT
t
3.
DOUBLE= 1UN / FIXED/
DOUBLE HUNG
4.
DOUBLE HUNG/
DOUBLE 14tU4G
WI NDOW SCHEDULE
WIND.
NO
ROOM
LOCATION
WIND.
TYPE
SIZE
W x H
TRIM FINISH
INT./ EXT.
REMARKS
DETAIL
SET
A
LIVING ROOM
3
5'-40" x 3'4"
STAIN/STAIN
9142.0
i3
BEDROOM 1
1
2'-10" x 4'-5"
STAN/STAIN
1/42.0
G
BEDROOM I
2
2'-8" x 4'-5"
STAIN/STAIN
SAFETY GLAZING REQU1R1_D
11;42.0
D
BEDROOM 2
2
2'-2° x 3'41"
ST'AN/STAIN
1,'42.0
E
BEDROOM 3
1
2"-6" x 4'-5"
STAIN/STAIN
1i'42:0
F
BEDROOM 3
2
2'-6" x 4'-5"
STAIN/STAIN
1142.0
6
KItCI4EN
1
31-4" x 3'-I"
STAN/STAIN
SAFETY GLAZING REQUIRED
2.142.0
H
LIVING ROOM
4
4'-10" x 3'-14"
STAINISTAIN
SAFETY GLAZING REQUIRED
1/42.0
TYPICAL WINDOW SCHEDULE NOTES
1. NOTE: WHERE SAFETY GLAZING IS INDICATED, BUT NOT
SCHEDULED IN SECTION 08 80 00, ALL UN LAMINATED GLAZING
PANELS IN THAT UNIT ARE TO BE TEMPERED. LAMINATED GLAZING
PANELS NEED NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR
IDENTIFICATION AS SAFETY RATED GLAZING PER CODE.
2. FIELD VERIFY ALL EXISTING WINDOW OPENING DIMENSIONS.
HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR
WINDOWS AND INTERIOR! EXTERIOR WOOD TRIM. CONTRACTOR
SHALL COORDINATE WITH HOMEOWNER PRIOR TO START OF
WORK.
4. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'A' ON WINDOW TYPES, SCHEDULE & DETAILS SHEET.
SLOPE
1" min:
HEMMED EDGE
END CLOSURE
HEAD FLASHING DETAIL TYP.
3" = 1' - 0"
(E) WD. SIDING
CAREFULLY LIFT (E) WALL UNDI=RLAThENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHING. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING TYP AT HEAD At4D JAMB
REMOVE (E) WOOD SIPfN6 FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM REPLACE OR RE
INSTALL SIDING AS R1 Q'D. MAINTAIN
(E) COURSING. PAINT MODIFIED 61P TNG
TO MATCH (E) SIDING
PRE -PRIMED, GAO/ SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRAAIE. COLOR TO
HE SELECTED N NE FIEL
TRIM- MATCH (E) TRIM PRIMEALL
SIDES AND PANT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
!BACKER ROD t SEALANT
ACOUSTICAL. WINDOW ASSEMBLY
REMOVE (E)1.1.0. SIDING FOR
i
(E) GWB
(E) WALL LNDERI..ATENT
(E) EXTERIOR WEANING
SELF ADHERING:
MEMBRA
—TOUCH UP PAINT, AS REAP
CONTINUOUS
SEALANT, TVP.
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENING FRAMING. LIFT (E)
WALL UNDERLAYMENT;ANP LNSTALL
WINDOW / NAILING FLANGE OVER SELF
ADI•IERING MEMBRANE PENETRATION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEMBRANE OYER
NAILING FLANGE AND LAP UNDER (E)
WALL UNDERLAYMENT. CAULK NEW
VERTICAL SIDING JOINTS 4 SET NAIL
HEADS ELUSN. PAINT MODIFIED SIDING
TO MATCH (E) SIDING
(E) WD. SIDING
(E)WALL UNDERLAYMENT
(E) EXTERIOR SWEATI.4INCs
BACKER ROD 4 SEALANT
WINDOW HEAD
SOLID WOOD TRIM
WD. JAMB LINING
SEALANT
SI.41M AS NECESSARY
FILL GAP W/ BATT
INSULATION
(E)G1113
TOUCH UP PAINT, AS REQ'D
CONTINUOUS
ACOUSTICAL WINDOW ASSEMBLY
ACOUSTICAL WINDOW ASSEMBLY
SACKER ROD 4 SEALANT
WINDOW NAILING FIN
17-15-A
II II II
WINDOW JAMB
SEALANT, TYP.
SOLID WOOD TRIM`
WD JAMB LININGS
SEALANT
SLIM A5 NECESSARY
FILL GAP W/ BATT
INSULATION
3/4"
TRIM- MATCH (E) IRIM PRIME ALL
SIDES 4ND PAINT TO MATCH (E.) TRIM.
COLOR TO BE FIELD DETERMINED
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCI4 (E) SIDING
(E) EXTERIOR 5HEATHMCs
(E) IUD SIDINGS
BACKER ROD 4
SEALANT
3I4" WOOD SILL
SOLID WOOD TRIM
CONTINUOUS
SEALANT, TYP.
TOUCH UP PAINT, AS REQ'D
SELF -ADHERING
MEMBRANE
WINDOW SILL
WOOD SIDING -WINDOW DETAIL SET
3" 1' - 011
(E) WD. SiPINCs
CAREFULLY L FT (E) WALL UNDERLAYMENT
AND INSTALL SELF-ADHERNG MEMBRAM
PENETIRATION FLASI-1INr. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLAS141N4 TYP AT I.IEAD AND JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING A3 REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIDING
TO MATCH (E) SIDING.
PEE -PRIMED, GALV SHEET METAL.
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE. COLOR TO
BE SELECTED IN THE FIELD
TRIM- MATC14 (E) TRIM. PRIME ALL
SIDES AND PAINT TO MATCH (E) TRIM.
COLOR TO BE FIELD DETERMINED
BACKER ROD 4 SEALANT
ACOUSTICAL WINDOW ASSEMBLY
REMOVE (E) WI?. SIDING FOR
(E)GU.13
(E) WALL- UNDE1.AYMENT
(E) EXTERIOR 514E.ATHING
SELF ADHERING'
MEMBRANE
TOUGH UP PAINT, AS REQ'D
CONTINUOUS
SEALANT, TYP.
INSTALLATION OF NEW WINDOW TRIMS
AND REATTACHMENT OF (E) SIDING TO
WINDOW OPENING !CRANING. LIFT (E)
WALL UNDERLAYMENT MD INSTALL
WINDOW ! NAILING FLANGE OVER SELF
ADIy4ERING MEMBRANE PE'NETRAT'ION
FLASHING. INSTALL SECOND LAYER OF
SELF ADHERING MEI-IBR.NE OYER
NAILING FLANGE AND' LAP UNDER' (E)
WALL UNDERLAYMENT.,CAULK NEW
VERTICAL, SIDING JOINTS 4 SET NAIL
HEARS FLUSH. PAINT MODIFIED 6I1DING
TO MATCH (E) SIDING
(E)1LC3.3IDING
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATHING
BACKER ROD 4 SEALANT
WINDOW HEAD
SEALANT
514IM AS NECESSARY
FILL GAP' W/ BATT
INSULATION
(E) CERAMIC TILE
(E) 61$,
CONTINUOUS
SEALANT, TYP
SOLID WOOD TRIC'1
ACOUSTICAL WINDOW ASSEMLY
ACOUSTICAL WINDOW ASSEMBLY
BACKER ROD t SEALANT
WINDOW NAILING FIN
WINDOW JAMB
1113 JAMB LINING
SEALANT
S44IM AS NEC:ESSAIRY
PILL GAP'W[ BATT
INSULATION
3/4"
BAICI R ROD 4
SEALANT
3/4" WOOD SILL
SOLID WO OD TRIM
CONTINUOUS'
SEALANT, TTP.
SELF -ADHERING.
TRIM- MATG1-II (E) TRIM. PRIME ALL
SIRES AND PAINT TO MATCH(E) TRIM.
COLOR TO BE FIELD DETERMINED
£MOVE (E) WOOD SIDING FOR
INSTALLATION OF NEW WINDOW
ASSEMBLY AND TRIM. REPLACE OR RE
INSTALL SIDING AS REQ'D. MAINTAIN
(E) COURSING. PAINT MODIFIED SIplNCs
TO MATCH (E) SIDING
(E) EXTERIOR 4EATI-TING
(E)WD 91D1NCs
WINDOW SILL
MEMBRANE
(E) CERAMIC TILE
(E) GOB
WINDOW
O B
WOOD SIDING- WINDOW DETAIL SET
3"=11-0"
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14 'mi
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
-'ERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DEI,R.IDCE WAY SW
SUITE 2C0• SEATTLE, WA 98146
(266) 624-2777 • FAX (206)-624-297a
OCTOBER 19, 2012
0810 03.2328
ce
0
J
0
z
ce
w
0
C,
0
MPROVEMENTS
a
w
w
0
z
LL
CL
z
w
co
w
ce
AIP NUMBED
3-53-0058-045
DATE
OCTOBER 19, 2012
ISSUED
100°! CD
PROJECT ARCHITECT
JO
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
WINDOW
TYPES,
SCHEDULE &
DETAILS
A2.0
0810.03.2328
DOOR TYPES
-Or
A
FLUSH 5CU)
UV WAGON WHEEL
AND 4 PANELS
W/ SAFETY GLAZING
Wi OBSERVATION PORT
ES
SECONDARY 'SLIDING
GLASS DOOR
W/ SAFETY GLAZING
c
FLUSH SCUJ
1 LITE LW
2 PANELS
LU/SAFETY GLAZING
EXTERIOR
eNGLE LEAP StORM
IIJ/ SAFETY GRILLE
DOOR SCHEDULE
DOOR
NO
ROOM
LOCATION
DOOR
TYPE
SIZE
W x H
FINISH
INT./ EXT.
HARDWARE
SET / FINISH
KNOB / LEVER
SET
LOCK
SET
DETAIL
SET
- 1
ENTRY
A
21-8'1 x 6J -S"
STAIN/ STAIN
1-1W-1 / 60S
DK -4
LOCK -1
1/42.1
2
KITCHEN
5 -
6'-0". x 6'-8"
2/,42.1
3
KITC14EN
C
2'-8" x 6'-S"
STAN/ STAIN
Hi1J-1 / 60$
DK -4
LOCK -1
1/42.1
4
ENTRY
0
2'-8" x 6'4"
1/421
5
KITCHEN
D
2`-fr x 6'43"
1142.1
TYPICAL DOOR SCHEDULE NOTES
1. WHERE SAFETY GLAZING IS INDICATED, BUT NOT SCHEDULED IN
SECTION 08 80 00, ALL UNLAMINATED GLAZING PANELS IN THAT
UNIT ARE TO BE TEMPERED. LAMINATED GLAZING PANELS NEED
NOT CONTAIN TEMPERED GLASS, BUT SHALL BEAR IDENTIFICATION
AS SAFETY RATED GLAZING PER CODE.
2. SLIDING GLASS DOORS SHALL MATCH THE OPERATION OF THE
EXISTING SLIDING GLASS DOORS THEY REPLACE OR COVER.
3. FIELD VERIFY ALL EXISTING DOOR OPENING DIMENSIONS.
4. HOMEOWNER SHALL MAKE FINAL FINISH SELECTIONS FOR DOORS
AND INTERIOR/ EXTERIOR WOOD TRIM. CONTRACTOR SHALL
COORDINATE WITH HOMEOWNER PRIOR TO START OF WORK.
5. FOR HEAD FLASHING INSTALLATION REFER TO HEAD FLASHING
DETAIL 'AON DOOR TYPES, SCHEDULES &DETAILS SHEET.
6
I" min.
1''"
ti- ---
14EM11ED EDGE END CLOSURE
HEAD FLASHING DETAIL TYP.
3" = 1' -0
(E) U SII:)ft4G
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL. SELF -ADHERING MEMBRANE
PENETRATION FLA8-1M. LAP (E) WALL
UNDERLAYMENT OVER I=ENETRATION
FLASHINts. TYP AT HEAD .410 JAMBS.
REMOVE (E) WOOD SIDING FOR
INSTALLATION CF NEW POOR ASSEMBLY
AND TRIM. REPLACE OR FE INSTALL
SIDING AS REQ'D. MAINTAIN (E)
COURSING. FAINT MODIFIED SIDING TO
MATCH (E) SIDING.
PRE-FRIMED, GAO/ SHEET MIX
FLAWING UJ/ END CLOSURE INDER
SELF-API-IERNG MEIIISWNE. COLO IR TO
BE SELECTED IN THE FIELD
CONTINUOUS SEALANT BEHIND Z BAR
FRAME
STOW DOOR PER SCHEDULE
2" MINL
(E) EXTERIOR SHEATHING
SELF -ADHERING
MEMBRANE
TOUCH UP PANT AS, REQ'D
CONTINUOUS
SEALANT, TYP.
SOLID WOOD TRIM
SHIM AS NECESSARY
FILL GAP LIU BATT
INsuLATIoN
loop FRAME
KERF A5 REQUIRED FOR
WEATHER STRIPPING
INSTALLATION
CONTINUOUS WEATHER-
STRIPPING
DOOR PER SCHEDULE
Remove (E) U. SIDING FOR INSTALLATION
OF NEW DOM TRIMS AND REAnA041,ENT
ci (E)SIDNG TO DOOR OPENING FRAM1%,
LIFT (E) WALL UNDERLAYMENT AND INSTALL.,
SELF ADHERNG MEMBRANE PENETRATION
LAS -IG. INSTALL SECOND LAYER CF
SELF ADHERING MEMBRANE AND LAP
UNDER (E) WALL UNDERLAYMENT. CAULK
NEW VERTICAL SIDING JOINTS 4 SET NAIL
HEADS FLUSH. PAINT MODIFIED SCING TO
MATCH (E) SIDING
(E) WOOD SIDING
CONTINUOUS SEALANT 1515J -IND
BAR FRAME
STORM DOOR PER SCHEDULE
KERF AS REWIRED FOR ILEATI-IER
STRIPPING INSTALLATION
CONTINUOUS UEATHER-STRIPPNG
JAMB BEYOND
DOOR HEAD
11
;et
(E) EXTERIOR SHEATHING
TOUCH UP PAINT, AS REQ'D
CONTINUOUS
2" MIN.
DOOR JAMB
U/OOD DOOR PER SCHEDULE
Dt)OR SHOE
2" MIK
DOOR SLLEEP
ALLIIINUM THRESHOLD
ADJUSTABLE BLEEP
EXISTING FLOOR STRUCTURE
SILL IN IAD OF SEALANT
DOOR SILL
SEALANT, TYP.
ExiSTING FRAMING
SOLID WOOD TRIM
SHIM AS NEcEssAfRy
FILL. GAP W/ BATT
INSOLATION
DOOR PER 50-IEDULE
WOOD SIDING - DOOR DETAIL SET
3" = 1' - 0"
(E) WD. SIDING
FRE -PRIMED, (.ALV SHEET METAL
FLASHING W/ END CLOSURE UNDER
SELF -ADHERING MEMBRANE COLOR TO
BE SELECTED N THE FIELD
SELF -ADHERING 11EMORANE. TURN DOLLN
OVER FRONT EDGE OF TRJI ENSURE
NO MEMBRANE vISIIBLE !BELOW
FLAWING EDGE
2X TAPERED CAP
REMOVE (E) SIDING TO FACILITATE
INSTALLATION a FLAWING AND POOR
HEAD ASSEMBLY
TRIM- PAINT TO MATc.44 (E) TRIM
CONTINIOUS 2x SOLID !BLOCKING
AROUND PERIMETER CF DOOR FRAI1E.
PAINT ALL EXPOSED EDGES TO MATCH
(E) TRIM
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R
INSTRUCTIONS
(E) WALL UNDERLAYMENT
(E) WALL UNDERLAYMENT
(E) EXTERIOR SHEATI-ING
SELF-ADI4ERING MEMBRANE
IREmovE (E) woo SIDING AND
REPLACE AS REGI'D. LIFT (E)
WALL UNDERLAYMENT AND
INSTALL SEI-F-APHERING
MEMBRANE PENETRATION
FLASHING. LAP (E) WALL
UNDERLAYMENT OVER TOP OF
PENETRATION FLASHING PAINT
MODIFIED SIDING TO MATCH (E)
SIDING TYR AT I-EAD AND
JAMBS
DOOR HEAD
13AcKER Rol, AND SEALANT
5ELF-ADHEARING reisRANE
TRIM- PAINT TO MATC14 (E) TRIM
CONTINUOUS 2x SOLID !BLOCKING AROUND
PERIMETER CF DOOR FRAME PAINT ALL
EXPOSED EDGES TO MATCH (E) TRIM
TRIM- PAINT TO MATCI4 (E) TRIM
SELF -ADHERING MEMBRANE
SECONDARY SLIDING STORM DOOR
ASSEMBLY. INSTALL PER MFG'R INSTRUCTIONS
IUD. TRIM BEYOND
SOLID WOOD LINING -
(E) PRIMARY SLIDING POOR
ASSEtIELY.
(E) U10. SONG
(E) EXTERIOR 5HEATI4M
LIFT (E) WALL UNDERLAYMENT.
LAP NEW til0EIRLAYMENT UNDER
(E) LNDERLAYMENT 2" AND
CONTINUE O'ER SLIDING GLASS
DOOR FRAME
SECONr)ARY SLIDING STOW DOOR
ASSEMBLY. INSTALL PER MFGR INSTRUCTIONS
SEALANT
11
" MIK BEILLIeeli PRIMARY
AND SECONDARY SLIDING
GLASS DOOR FRAMES
DOOR JAMB
EXISTING SUBSTRATE
DOOR SILL
SOLID WOOD LINING
(E) PRIMARY SLIVNG
61.AS6 DOOR
CE) SLIDING GLASS
DOOR
(E) FINISH FLOOR
(E) INTERIOR CONC. SLAIS.
OR (E) ID. FLOOR FRAMING
WOOD SIDING DOOR DETAIL SET
= 1' -
•
'sr
REVIEWED FOR
ODE COMPLIANCE
APPROVED
FEB 1. 4 Int)
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A 9totassional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 2E0 • SEATTLE, WA 98106
(208) 824-2777 • FAX (208) 824-2973
OCTOBER 19, 2012
0810.03.2328
0
tt.
0
z
ce
z
0
00
MPROVEMENTS
›-
w
co0
z
ce
co
ce
AIP NUMBER
3-53-0058-045
0
0
(0
DATE
OCTOBER 19, 2012
ISSUED
100% CD
PROJECT ARCHITECT
J
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
DOOR
TYPES,
SCHEDULE &
DETAILS
A2.1
081�03.2328
CAREFULLY LIFT (E) WALL UNDERLAYMENT
AND INSTALL SELF -ADHERING MEMBRANE
PENETRATION FLASHNG. LAP (E) WALL
UNDERLAYMENT OVER PENETRATION
FLASHING. TYP AT HEAT) AND JAMBS.
WIC:YE (E) WOOD SIDING FOR
INSTALLATION CF VENT FIXTURE AND
FLASHING. REPLACE OR RE INSTALI-
SIDING AS REQD. MAINTAIN (E)
COURSING. PANT MODIFIED soks TO
MATCH (E)
PM -PRIMED, GALV. SHEET METAL
FLASHING P.F_ END CAPS UNDER
SELF -ADHERING MBISRANE. EXTEND
PLASHING 4" UP WALL. PAINT COLOR TO
E3E SELECTED IN THE FIELD
PAINT VENTILATION 1400D,
COLOR TO ISE SELECTED IN
THE FIELD
EXTERIOR VENTILATION 14001).
REF. MECH.- PAINT INTERIOR Wit
ACOUSTICAL DAMPING
CasIPCUI4D. SET IN MASTIC AT
EXTERIOR TRIM.
(E) WALL UNDERLAYMENT
SELF -ADHERING MEMBRANE
(E) EXTERIOR SHEATHING
REMOVE 1 REPLACE (E) SIDING AS
REQUIRED.
2X BLOCKING
2X2 CONTINUOUS PRESSURE
TREATED BLOCKING, 4 SIDES
AIR INTAKE DETAIL AT EXTERIOR
311 = 1' - 0"
EXIST. WALL
CONSTR.
ExIST. GABLE
VENT
NEW ix GALV
HARDWARE
CLOTH
2X BLOCK
(2) IMPA-34
EACH SIDE PANEL
OPEN TOP
1" COX FLY
AT (3) SIDES
1" OWENS CORNING nee
INSULATION TYPICAL
SECURE wrm PIN TYPE
FASTENERS TO PLYWOOD
BACK AND SIDE PANEL
NOTE:
AFTER FABRICATION,13AFPLE 51-1ALL SE SECURELY
ATTACHED N POSITION.
2. NEW BAFFLE SHALL BE AT LEAST AS WIDE AS
THE EXISTING VENT OFENNG.
(E) INTERIOR WIDE TRIM PHOTO TYP.
NTS
(E) EAVE VENT. MAY VERY
AT EACH FROF'ERTY.
!BLOM IN CELLULOSE
INSULATION WITH A COMBINED
VALUE CF NOT LESS THAN
R-38
INSULATION DAM
(E) WALLffIN
EXISTING sioNs
CAREFULLY LIFT (E) WALL UNDERLATMENT
AND INSTALL TOP EDGE CF SELF
ADHERING MEMBRANE ACsAINST
514EATHING. EXTEND SELF ADHERING
MEMBRANE 4' UP WALL FROM TOP OF
FI-ASHING. LAP (E) WALL UNDERLAYMENT
OVER TOP OF EELF ADHERM MEMBRANE.
TYP AT HEAD AND JAMS.
REMOVE (E) SIDING AS REQ'D FOR
INSTALLATION OF DOOR ASSEMBLY 4
TRIM. REPLACE 11/ NEW SIDING 4 PAINT
TO MATCH (E) SIDING
24 GA PRE -PRIMED GAI-V. S1-EET METAL
FLASHING WITH END CLOSURE UNDER
SELF-AD14ERIN MEMBRANE. EXTEND
FLASHING 4" UP WALL
WOOD FRAMING AT HEAD/JAMBS/SILL
SOLID Woop TRIM
POOLE FLAP PET
DOOR INSTALL PER MANUF'R
RECOIMENDATIONS
PET DOOR DETAIL
3'1= 11- 0"
ETCEILIN
T 14ERE
Ur
4"PIIN
ACCFPTABLE
HERE
NOTE: permovE EXISTNG SMOKE
DETECTORS, CUT AND PATCH CEILINGS AS
REQUIRED. IREMOVE ALL PAINT LINES,
PROVIDE SWEET ROCK, TAPE AND
TEXTURE MO PAINT TO FILL ALL HOLES
LEFT FROM EXISTING CONDITION. PAINT
TO MATCH SURROUNDING CONDITIONS.
DETECTOR 1
SELF ADHERING
MEMBRANE
(E) EXTERIOR
51-EATHING
TOUCH UP PAINT,
AS REQ'D
E
9 -
SIDE WALL
NSTALLATION DETAIL TYP.
SEALANT
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14 loll
•
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
?ERMIT CENTER
b
311 = 1' - 09
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 21:10 • SEATTLE, WA 9010E
(206) 624-2/77 • FAX (206) 624-2072
OCTOBER 19, 2012
0810.03.2328
KING COUNTY
MPROVEMENTS
AIP NUMBER
3-53-0058-045
0
CO
DATE
OCTOBER
OCTOBER 19,2012
ISSUED
100% CD
PROJECT ARCHITECT
J
PROJECT MANAGER
ML&TF
DRAWN
LB&CP
MISC.
DETAILS
A2.2
0810.03.2328
LIFT (E)
UNDEWAYMENT
AWAY LOOSELY
FROM (E) SI4EATI-IM
AT JAMBS AND HEAD
NOTE: REMOVE (E) SONG BACK FROM (E) R. AS REQ'D
(E)erDING NOT WOLIN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDTER MEMBRANE FLASHING
WAS BEEN INSTALLED -
LAP SILL MEMBRANE
FLASHING 2-1/2"
OVER (E) BLDG.
PAPER AT SILL.
EXTEND I in BEYOND
RO. AT A. END a
GILL.
(E) WALL
LNDERLAYMEW
AT SILL
(E) SHEATHING
CUT SILL
FLASHING TO
EDGE OF R.O. AS
SHOU.N.
ADHERE
MEMBRANE
FLASHING TO
OUTSIDE MCE
OF WALL
SHEATHING
13" MN
MEMBRANE FLASHING AT SILL
SCALE: NTS
LIFT (E) BLDG.
PAPER AWAY
LOOSELY FROM (E)
SHEATI-11140 AT
JAMBS AND 14E40.
(E) SIDING NOT
514011N FOR CLARIrr.
WINDOW NAL PLANE:
EMBED WINDOW HEAD
AND JAMB NAIL
FLANGE IN SEALANT.
ENSURE CO1PLE1E
SEAL BETWEEN
FLASHING AND WINDOW
FLANGES. SEALANT
SHOULD FLOW GUT
BEYOND EDGE OF
WINDOW FLA/4E AND
SHOULD FILL FLANGE
NAIL 140LES. REMOVE
EXCESS MATERIAL
00 NOT SEAL FLANGE
AT WINDEX) SILL
(E)11.141 -L
UNDERLAYMENT
AT SILL
REmovED
\C
BUTTERFLY COWER FLASHING
NOTE: REMOVE (E) Goit4 SACK MOM (E) RD. AS CI'D
(E) SIDING NOT 51-101.1.N FOR CI-AIRETY. REPLACE ANP
OR INSTALL NEW SIDING AFTER MEMI3RANE ffLAs4Na
4-I4S BEEN INSTALLED.
1
D
\
.
.
.
.,.
\ \
. .
ELEVATION VIEW
NOTE: INSTALL WINDOW PER MFG'R5 SPECIFICATIONS.
NOTIFY TEC.14NICAL REPRESENTATIVE OF DISCREPANCIES
r,1
WINDOW MEMBRANE INSTALLATION
SCALE: NTS
EDGE OF (E)
SIDNG, SHOWN
DIAGRAMATICALLY.
(E) SIDNG
NOT SHOUN
FOR CLARITY.
LAY (E) WALL
UNDERLAYMENT
BACK DOW
OVER FLANGE
FLASI-IING AT
JAMBS
NOTE: Remove (E) &DING BACK PROM (E) R.O. AS REOID
(E) sirma NOT SHOILN OR CLARITY. REPLACE AND
OR INSTALL NEW SONG AFTER MEMBRANE FLASHING
1445 BEEN INSTALLED.
L
HEAD FLASHING PREPARATION
MEMBRME
R.ASHING
PREVIOUSLY
APPLIED TO
WINDOW
OPENINGS.
I3END
ANCHORAGE
NAILS TOWN
OVER NAIL
FLAME, 14EAD
ONLY.
(E) SHEATHING
WHERE REQUIRED, TRIM
(E) LUALL
LNDERLAYMENT AT
I4EAD TO FREPARE
FOR INSTALLATION OF
I4EAD FLASHING AND
WINDOW 'TRIM
(FOLLOWNS STEPS).
SCALE: NTS
(E) WALL
LNDERLAYMENT
NOTE: REMOVE (E) SIDING BACK FROM (E) R.O. AS RE0'D
(E) SIDNG NOT 81-10iN FOR CLARITY. REPLACE AND
OR NSTALL NEW 810fl4G AFTEIR MEMBRANE FI-ASHING
HAS BEEN NSTALLED
CUT JAMB FLASHING TO
EDGE OF LUNDOUJ OPENING
AS S140.LN. EXTEND 1-1/2"
BEYOND EDGE OF
OPENING AT 14EAD, JAM13S,
AO SILL,
ADI-IERE
MEMBRANE
FLASHING TO
OUTSIDE FACE OF
WALL SHEATHING
NOTE: REMOVE (E)SICING BACK FROM (E) R.O. AS RE0D
(E) SIDIlsIG NOT 54011IN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLASHING
HAS BEEN INSTALLED.
NAILING RANGE AND FLASI-ING.
INSTALL S14T. METAL
I4EAD FLASHING
UNDER (E) BLDG
PAPER.
TRIMMED EDGE
OF (E)
DIAGWMATICALLY.
(E) SIDING MOT
SHOLLN FOR
CLARITY.
NOTE: REMOVE (E) SIDNG BACK FROM (E) R.O. AS mot)
(E) SIDING NOT SHOLN FOR CLARITY. REPLACE AND
OR INSTALL NEW SIDING AFTER MEMBRANE FLA -514M
4445 'EEN INSTALLED.
ALLOW I/6" CLEARANCE
ISETILEEN FLASHING AND
WT. EDGE OF (E)
SIDING.
HEAD FLASHING INSTALLATION
SCALE NTS
(E) WALL
UNDERLAYMENT
30 MEMBRANE FLASHING AT HEAD
SCALE: NTS
aUT 14E4"
FLASHM TO
EDGE OF WINDOW
OPENING AS
61401114. EXTEND
1-1/2" BEYOND
W. AT I4EAD
AND JAMBS.
AD1-ERE
PENETRATION
FLASI-1NG TO
OUTSIDE FACE OF
LUALL BREATHING
(T1r. EACI4 GIDE
Of WALL)
NOTE: REMOVE (E) SIOM BACK FROM (E) Ro. AS Feetz.D
INSTALL HEAD
FLANGE FL -A$-111'4
OVER WINDOW
NAILING FLANGE
AND FLASHING.
(E) SIDING NOT 01-1O11N FOR CLARITY'. REPLACE AND
OR INSTALL NEW SIDING AMER MEMBRANE PLASHING
1445 BEEN INSTALLED.
0
WINDOW FLASHING INSTALLATION
SCALE: NTS
0 WOOD TRIM INSTALLATION
9
SCALE. NTS
SHEET METAL I4F-AD
FLASHING
(E) SIDING
(E) BLDG. PAPER
BENEATH SIDING
INSTALL or). TRIM. WIT
TIGHT TO TRIMMED EDGE
OF (E) SIDING. APPLY
SEALANT BEAD TO
JOINT BETILEEN WINDOW
TRIM AND SIDING.
LEAVE 1/4"-3/8" GAP
BETWEEN W1ND01.1) TRIM
AND WINDOW MANE
INSTALL. CONT. BEAD OF
SEALANT AND IBACXER
FWD IN GAP.
GENERAL NOTES:
1: MEMBRANE FL-45141HG 16 SPECIFIED IN 01 62 00 AS
"SELF ADHEARING MEMBRANE FLASHING" TYPICALLY
IREFERED 10 46 "PEEL AND STICK"
2: DETAILS "I, 2, AND 3" REFER TO MEMBRANE
INSTALLATION PRIOR TO WINDOW INSTALLATION
3: DETAILS "13 AND 6" fiEPER TO MEMBRANE
INSTALLATION AFTER WINDOW 1445 SEEN SET IN PLACE,
SHIMMED. AND ANCHORED.
4 DETAILS "1 AND REFER TO 01-EET METAL I-IEAD
FLASHING.
5: DETAIL 43 REFERS TO WOOD TRIM AND CAULK
JOINTS.
o
REVIEWED FOR
CODE COMPLIANCE
APPROVED
FEB 14 'nil
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWIL
FEB 0 7 2013
PERMIT CENTER
S.MSTEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, illrA 98106
(208) 824-2777 • FAX (208) 824-2972
OCTOBER 19, 2012
0810.03.2328
ce
0
ce
0
z
0
0
0
MPROVEMENTS
›-
ce
0
z
LL
0
ce
F—
L.1.1
0
C/)
ce
AIP NUMBER
3-53-0058-045
DATE
OCTOBER 19,2012
ISSUED
100% CD
PROJECT ARCHITECT
J
PROJECT MANAGER
ML &TF
DRAWN
LB&CP
WINDOW
FLASHING
DETAILS
A2.3
0810.03.2328
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LING
LWT
M AX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
nipv
VD
VTR
W
WB
w/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDIN ATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STA -11C PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL AB,BR
•
•
XX
OR XX
0
X/Y
i'////////
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
UNE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION QF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-O" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAI
N 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
SYMBOL ,AMBO,
$G -X
XXX
1H
lb F-uP1*ms-mm4i=====:1-
f
f f
--m4C
5 r��
+ r +
DN
UP
VD
RA/EA
RG
SA
,1 SA
-0*1-I- RA/EA
SD
1>
111121111111112
0.0
-�
EA
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AM OU N T
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIP IDT OR EQUIPMENT LOCATION
MOD
NG NG
3
0
•
MOTOR OPERATED DAMPER
NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
WC -1
DESCRIPTION
VOLTS
PH
G08"WG
7"0
1,2
1,3
23
26
23
26
N/A
23
26
N/A
-
MOTOR OPERATED DAMPER
24
1
X
X
X
1,2
-
THERMOSTAT
24
1
X
X
X
1
1
REMARKS:
1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
SIZE
REMARKS
WC -1
EXTERIOR
90
337
G08"WG
7"0
1,2
1,3
REMARKS:
1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
(SQ. FT.)
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2328
1025
3
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE ('WAC),.
SECTION 51-51-1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
MIN VALUE INOTES'
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 011101 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW' TRIM PAINT.
THERMOSTAT/SWITCH HOURS OF OPERATION
SET FURNACE THERMOSTAT TO OPERATE 1 OF EVERY 2 HOURS.
RECEIVED
CITY OF TUKWILA
FEB 0 7 2013
'ERMVIII CENTER
MECHANICAL VENTILATION CALCULATION
PER SRC M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE 1508.2) 45.
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 45 / (1 X 1/2) = 90 CFM
d4�
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
S.M. STEMPER
ARCHITECTS
2 Pmfeeaion.1 Molted L MftJ CQmp*,
4000 DELRIDGE WAY SW
SUITE 200 ' SRATTLE, WA 88106
(206) 5Z4 -2x'9'1 FAX (208) t a2Y/S
THE GREENBUSCH GROUP, INC
ACCT fl0II ..
toon NMCi�/ vti!IiE16CIWN01i, o, IC
ISEA12.8,* se„sw
(206) 378-0858 (205) 378-0641 FAX
0810032328
IONAL AIRPORT
MPROVEMENTS
LLI
KING T' INTER!
RESIDENTIAL AIRCRAFT NOIS.
AIP NUMBER
3-53-0058-45
0
Fcn-
-§"
DATE
09/10/2012
'ED 100% CD
EXPIRES: 9/08/2014
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES,
DWG INDEX
M1.0
081003.2328
CRAWL
SPACE
ROUTE UP
IN JOISTS
HOLD DUCT
TIGHT TO WALL
LOWER FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
OUTSIDE AIR DUCT,
SIZE AND ROUTE
PER PLAN
VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
POC
J
0_
FURNACE
CEILING
FURNACE ELEVATION
SCALE: NONE
FLOOR
SEE
LOCATE 3' BELOW
DRYER VENT
NORTH
T
90
()SG
BEDROOM
1
BATH 1
LIVING
ROOM
(E)SG
GAS
METER
et<
E
E
E
DINING
ROOM
24" x 48" EXIST.
ATTIC ACCESS
PANEL
KITCHEN
0 MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
HARD DUCT
PER PLAN
2X BLOCKING
2X BLOCKING
SHEET METAL
FLASHING
WALL CAP
(E)SIDING
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
WALL CAP DETAIL
SCALE: NONE
(E) VENT
BEDROOM
2
BEDROOM
3
(E)SG
DRAWING NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE
SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM
10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR
NOXIOUS SOURCE PER SRC M1508.6.6.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING
MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE
WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8
HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO
SATISFY THE SEATTLE RESIDENTIAL CODE, CHAPTER
M1508.5.2 (CONTROLS FOR WHOLE HOUSE VENTILATION
SYSTEMS SHALL BE CAPABLE OF OPERATING THE
VENTILATION SYSTEM WITHOUT ENERGIZING OTHER
ENERGY—CONSUMING APPLIANCES). COORDINATE FINAL TIME
SETTING WITH PROJECT REPRESENTATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK—OUT WORK
HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF
TAB WORK, PERFORM THE FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR
BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS.
FLAG NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL
WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND
TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE SEC
1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A
LABEL TO THE CONTROLLER THAT READS "WHOLE
HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER SRC M1508.5.2.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE
MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON
M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E)
FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET
PER SRC M1508.5.1.
Dt3-0� b
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE
EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER
SHALL ALLOW FOR BALANCING THE OUTSIDE/RETURN
AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE
AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO
ORDERING'. IF A VOLUME DAMPER EXISTS IN THIS
LOCATION,, IT MAY BE REUSED. SEPARATE
PERMIT AND
APPROVAL
R`QUIRED
RECEIVED
CITY OF TUKWIL../
FEB 0 7 2013
'ERIUIII CENTER
EXPIRES: 9/08/2014
S.M. STEMPER
ARCHITECTS
S. Prat Dai Limited Liab Mtj Company
4000 DELR[DGE WAY SW
SUITE 200 • SEATTLE, WA 98100
(2Oe) eZ4-2777 , FAX (206) ei34-881e
TILE GREE,NBUSCH GROUP, INC
AG011S11 AL MOM / YCEO ! IEcIwI AL E110sE'FAMC
1909 SEW 190-�011 S91EU SLUE 901 SEATTLE; M190119
(206) 3711-06e9 (206) 376-0e41 FAX
CO
C*4
C
CD
CD
CO
KING COUNTY INTERNATIONAL AIRPORT
EDY IMPROVEMENTS
co
RESIDENTIAL AIRCRAF
AIF NUMBER
3-53-0058-45
TUKWILA WASHINGTON
DATE
09/10/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA. DT
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.2328
TO Rm.AcE
POILER SIPPLY
LOWER FLOOR PLAN
114"= 1'
ELECTRICAL LEGEND
I
I ; 0
A '71 Ft ION
I ISITIBM.
DESCIRirtION
UGHTING OR POWER PANEL
EQUIPMENT CONNECTION, SEE EQUIPMENT CONNECTION SCHEDULES
FOR SPEcIFIC REQUIREMEN1S.
______
m
o
BRANCH CIRCUIT WIRING AND CONDUIT AS REWIRED FOR (XTs DEVICES
NW
AND EQUIP INDICATED CM PUNS. (WIN AND CONDUIT SIE MAY NOT
APPEAR ON PLANS). PROVIDE CONDUCTORS MID CONDUIT PER NEC CODE.
(4)
DAMPER CONNECTION
1I2 MG, 1/2'C. MIN. EMT OR ROD STEEL 1 INDICATES EQUIP GND.
1 1101CATES ISOLATED GROUND.
MAST, WEATHERHEAD
D
a
NON-FUSED DISCONNECT SitItH
1DGGLE TYPE MOTOR DISCONNECT SWITCH WITH THERMAL OVERLOADS
-----0.--
I:E3
BRANCH ORCUIT HOME RUN
ELECTRICAL METER
0.3
I
SMOKE DETECTOR
TIER OPERATE) SWITCH
--- --
AERIAL SERVICE CONDUCTORS, COORDINATE ICH UTILITY.
CEILING MOUNTED FIRE ALARM -VISUAL MODE UGHT
0
THERMOSTAT
UNE VOLTAGE FIRE ALARM SMOKE/CARBON MONOXIDE DETECTOR
ELECTRICAL - PROJECT NOTES
1. CONTRACTOR AND THEIR SUBCONTRACTORS TO HAVE ACCESS TO HOUSE BETWEEN 8:00 AM TO 5:00 PM, ALL ELECTRICAL WORK FOR EACH
DAY MUST BE COMPLETED IN THAT TIME PERIOD.
2. ISOLATED DEMOLITION OF WALL AREAS TO FACILITATE INSTALLATION OF ELECTRICAL DEVICES SHALL BE LIMITED, PATCHED AND PAINTED
AFTER WORK IS COMPLETED.
3. MAXIMUM POWER OUTAGE IS TO BE NO LONGER THAN EIGHT HOURS. POWER MUST BE PROVIDED AT EACH UNIT BEFORE 8:00 AM & AFTER
5:00 PM.
4. WHERE NEW ELECTRICAL EQUIPMENT OR DEVICES REPLACES EXISTING, CUT AND PATCH AS REQUIRED. REMOVE ALL PAINT UNES, PROVIDE
SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION OR NEW ROUGH -IN. PAINT TO MATCH
SURROUNDING CONDITIONS.
5. REMOVE EXISTING SMOKE DETECTORS, CUT AND PATCH CEILING AS REQUIRED. REMOVE ALL PAINT LINES,
PROVIDE SHEET ROCK, TAPE AND TEXTURE AND PAINT TO FILL ALL HOLES LEFT FROM EXISTING CONDITION.
PAINT TO MATCH SURROUNDING CONDITIONS.
ELECTRICAL PLAN NOTES
C) PROVIDE CONNECTION FOR 24V DAMPER. PROVIDE TOGGLE SWITCH AS DISCONNECT. ACQUIRE 24V POWER FROM FURNACE.
0 PROVIDE COMPLETE CONNECTION FOR MOTORIZED DAMPER AND THERMOSTAT. COORDINATE WORK WITH MECHANICAL DRAWINGS.
0 PROVIDE TIMER SWITCH AND COMPLETE CONNECTIONS FOR SUMMER MODE OPERATION. SEE WIRING SPECIFICATIONS FOR SWITCH.
TO FUTRINIAce
DAPPER
.47
I
---- ---------
MAIN FLOOR PLAN
1/4" = 1'
NORTH
RECEIVED
CITY OF TUKWILA,
FEB 0 7 2013
PERMIT CtNTER
SEPARATE
PERMIT AND
APPROVAL
REQUIRED
•
S.MSTEMPER
ARCHITECTS
A Professional Limited liability Company
4000 DELRIDGE WAY SW
SCITE 200 SEATTLE, WA 98108
(206) 624-2777 • PAX (206) 024--23
•
ENGINEERS. INC
SW WIWI ali. SIM SIM la
Mai% 6.0041110
VAIIIVISZI fin SSA
1111111 el MS
0810.032328
0
Ce
1-
0
0
0
REMEDY IMPROVEMENTS
RESIDENTIAL AIRCRAFT NOI
AIP NUMBER
5-53-0058-045
TUKWILLA WASHINGTON
DATE
SEPT 17, 2012
ISSUED
95%
PROJECT ENGINEER
CHL
PROJECT MANAGER
BCR
DRAWN
BCR
FLOOR
PLANS
NOTES
E1.0
0810.03.2328