Loading...
HomeMy WebLinkAboutPermit D13-210 - REAL TIME STAFFING - TENANT IMPROVEMENTREAL TIME STAFFING 16040 CHRISTENSEN RD D13-210 City ofiltukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206.431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049039 Address: 16040 CHRISTENSEN RD TUKW Suite No: Project Name: REAL TIME STAFFING DEVELOPMENT PERMIT Permit Number: D13-210 Issue Date: 08/05/2013 Permit Expires On: 02/01/2014 Owner: Name: BRCP RIVERVIEW PLAZA LLC Address: 248 HOMER AVE , PALO ALTO CA 94301 Contact Person: Name: TARA STROYAN Address: 1326 5 AV, STE 400 , SEATTLEW A 98101 Contractor: Name: GATEWAY CONSTRUCTION SRVCS INC. Address: 5602 2ND AVE S , SEATTLE WA 98108 Contractor License No: GATEWCS992C3 Lender: Name: SELF-FUNDED BY OWNER Address: Phone: 206 587-7120 Phone: (206)621-9111 Expiration Date: 03/04/2014 DESCRIPTION OF WORK: INTERIOR TENANT IMPROVEMENT OF TWO NEW DOORS AND ONE NEW SIDELIGHT Value of Construction: $23,379.00 Fees Collected: $905.73 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2009 Type of Construction: IIB Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-210 Printed: 08-05-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N Number: 0 N Start Time: Volumes: Cut 0 c.y. Start Time: Sanitary Side Sewer: Sewer Main Extension: Private: Storm Drainage: Street Use: Profit: N Water Main Extension: Private: Water Meter: N Permit Center Authorized Signature: Date: Size (Inches): 0 End Time: Fill 0 c.y. End Time: Public: Non -Profit: N Public: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: th L This permit shall b or abandoned for a null a d voi d of 180 PERMIT CONDITIONS: • Date: if the yi.r4k is not commenced within 180 days from the date of issuance, or if the work is suspended s from the last inspection. 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D13-210 Printed: 08-05-2013 7: There shall be no occupancy of a building 1 final inspection has been completed and moved by Tukwila building inspector. No exception. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 10: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-210 Printed: 08-05-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: Iti 1;2213 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: CAI , Ki g Co Assessor's Tax No.: 223 CiOrTg CA IriV)�/� '�OU 01 1 V/.Suite Number: I Floor: T' 'frj PROPERTY OWNER j�y� Company Name: ►fr. cr,(5W, Name: V luie w tA6 Address: j-2)2/„ F r1 �u, j9C Address: 110 /At a x.s tri JCS ev �y��y�� Phone: Zvl(� rg1• 1 .I' l.1(Z bvA ! City:c—rJv , - `1 I kx, State: V)y) Zip:C,} p CONTACT PERSON - person receiving all project communication j�y� Company Name: ►fr. cr,(5W, Name: 'Tam Si -y -D Address: j-2)2/„ F r1 �u, j9C City: State: , ^` `/1 Zip: I :' V km �y��y�� Phone: Zvl(� rg1• 1 .I' l.1(Z bvA ! \ rL..e Email: �• e. (� \o"..cgs 3 $ r GENERAL CONTRACTOR INFORMATION j�y� Company Name: ►fr. cr,(5W, Architect Nam • gip • ,I Address: �9 /1� c7 -t h �/�, ,� . \-7.9(r,��e"": )) Company Name: 1 l',}-1 Address: Phone `7 H „r 1 2lJ F71-1 .1 V Email: �Qc x Im Ws -1S ck6I, City: State: Address: Zip: Phone: Fax: City: State: Contr Reg No.: Exp Date: Fax: Tukwila Business License No.: Email: Ii':\pplicui,t, low, .111.1 ()ji I Re, iced: :\ueusl 2011 hh 21111.\ppL..iti PclS-^-I I 1 New Tenant: ❑ Yes X.No ARCHITECT OF RECORD j�y� Company Name: ►fr. cr,(5W, Architect Nam • gip • ,I Address: �9 /1� c7 -t h �/�, ,� . \-7.9(r,��e"": )) City: Stat 1� Zi 1 - p� `C Phone `7 H „r 1 2lJ F71-1 .1 V Email: �Qc x Im Ws -1S ck6I, ENGINEER OF RECORD Name:� �v 1Ce Company Name: — V°► Address:" Engineer Name: 1 `/Zip: Address: State: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name:� �v 1Ce A leA3 �-lJ`. — V°► Address:" 1 `/Zip: City: State: Page I 014 22 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ L 2719 Existing Building Valuation: $ Describe the scope of work (please provide d tailed information):t),c- oktio,cc ayvA ykcIAA) Will there be new rack storage? ❑ Yes y..4No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (speci Iv) riWill there be .torage or use of flammable. combustible or hazardous materials in the building? ElYes , No /1 :l'es's attach /is/ uimaterials and storage hat allow wt a. epunrtr 8-1/2 .r 11- paper incluchnr quantifies and Material Sa/i'f ufu Sheets. • SEPTIC SYSTEM ❑... ()n -cite ticptic ',Iem — I r it <cpltc , stem. pi 0% 2 copies uta currcot septic design appnwed by Kine County Health . Department. II .\pplicatl..11{ \HT1,' att.q,_ LM i.in Ke, iscd August 21)1I hh I'a_e 2 til t Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 15' Floor \S% % r ,�SIV 1�^J 2nd Floor 1 �Pc ,J� "� t" 3rd Floor 61 v'✓cp tt/ -.:-- Po t37 Floors thru « Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (speci Iv) riWill there be .torage or use of flammable. combustible or hazardous materials in the building? ElYes , No /1 :l'es's attach /is/ uimaterials and storage hat allow wt a. epunrtr 8-1/2 .r 11- paper incluchnr quantifies and Material Sa/i'f ufu Sheets. • SEPTIC SYSTEM ❑... ()n -cite ticptic ',Iem — I r it <cpltc , stem. pi 0% 2 copies uta currcot septic design appnwed by Kine County Health . Department. II .\pplicatl..11{ \HT1,' att.q,_ LM i.in Ke, iscd August 21)1I hh I'a_e 2 til t PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OR U' O70 D A Signature:n ►� k Print Name: l a (% 'S Irt Mailing Address: 1210 "d 2n1I :\Iq4 Rr, is cI: August _n 1 I 1,11 I Date: (0.1 • Day Telephone: 9a0 %**1 • �_1204(9 VOPE 1 1 City State Zip • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.Tukwila WA.Rov Parcel No.: 2523049039 Address: 16040 CHRISTENSEN RD TUKW Suite No: Applicant: REAL TIME STAFFING RECEIPT Permit Number: D13-210 Status: APPROVED Applied Date: 06/13/2013 Issue Date: Receipt No.: R13-02295 Initials: User ID: WER 1655 Payment Amount: $550.70 Payment Date: 08/05/2013 03:09 PM Balance: $0.00 Payee: KATHY DOUGHERTY TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 048876 ACCOUNT ITEM LIST: Description 550.70 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 546.20 640.237.114 4.50 Total: $550.70 Printed: 08-05-2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049039 Address: 16040 CHRISTENSEN RD TUKW Suite No: Applicant: REAL TIME STAFFING RECEIPT Permit Number: D13-210 Status: PENDING Applied Date: 06/13/2013 Issue Date: Receipt No.: R13-01876 Payment Amount: $355.03 Initials: JEM Payment Date: 06/13/2013 08:31 AM User ID: 1165 Balance: $550.70 Payee: BURGESS DESIGN, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 012276 355.03 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 355.03 Total: $355.03 Prinfprl• INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: R .AL -T-04 'IL SiAti-%trv_ Type of Inspection: \--2AoiNh- ik16- Address:dress: 1(oOyO C"(1RIs-Tfk)Ggk) RD Daalled: t—I cJA i__ Special Instructions: Date anted: lilpi—�3 (� tErm. p.m. Requester: Phone No: caoG-7go— 73 6; Kproved per applicable codes. 0 Corrections required prior to approval. 2 COMMENTS: 2e., To -714..e Date: 52,3_0 n REINSPECTION FEE REQUIRED. Prior to nex inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. ° PERMii COORD C\ PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-210 DATE: 06/131/13 PROJECT NAME: REAL TIME STAFFING SITE ADDRESS: 16040 CHRISTENSEN RD, STE 101 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: oJ'lel 1 Building Division ■ \ V % A)IA- Public Wor s COLPti 11 Fire Prevention m Planning 'vision Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete N, Incomplete ❑ DUE DATE: 06/18/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Xi Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/16/13 Approved ❑ Approved with Conditions 'X Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Prii er Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name GATEWAY CONSTRUCTION SRVCS INC UBI No. 602086011 Phone 2066219111 Status Active Address 5602 2Nd Ave. S. License No. GATEWCS992C3 Suite/Apt. License Type Construction Contractor City Seattle Effective Date 2/26/2001 State WA Expiration Date 3/4/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status NIELSC'02708 NIELSEN CONSTRUCTION Construction Contractor General Unused 9/28/1998 9/15/2000 Archived Business Owner Information Name Role Effective Date Expiration Date SACCO, RONALD President 02/26/2001 Bond Amount NIELSEN, CRISTIAN Vice President 02/26/200.1 105165492 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 TRAVELERS CAS & SURETY CO 105165492 08/19/2008 Until Cancelled $12,000.0008/21/2008 07/24/2013 2 RLI INSURANCE CO SRS1008614 02/26/2002 08/19/2008 03/25/2012 $12,000.00 03/04/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name , Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 13 Travelers Indemnity Company Th DTC0527D03331ND12 08/01/2012 08/01/2014 $1,000,000.00 07/24/2013 12 Charter Oak Fire Ins Co DTC0527D0333C0F1108/01/2011 08/01/2012 $1,000,000.0007/28/2011 11 CHARTER OAK FIRE INS CO DTC0527D0333C0F1008/01/2010 08/01/2011 $1,000,000.00 07/28/2010 10 CHARTER OAK FIRE INS CO DTC0527D0333C0F0908/01/2009 08/01/2010 $1,000,000.00 07/31/2009 9 CHARTER OAK FIRE INS TC05451M120C0F08 08/01/2008 08/01/2009 $1,000,000.00 08/01/2008 8 CONTINENTAL WESTERN INS CWP2699920 08/01/2008 08/01/2009 $1,000,000.00 07/24/2008 7 LIBERTY NORTHWEST INS CO3162727 08/01/2006 08/01/2008 $1,000,000.00 08/01/2008 Summons/Complaint Information Cause ' County Complaint Judgment ' Status' Payment'Paid Byl httos://fortress.wa.2ov/lni/bbip/Print.aspx 08/05/2013 GENERAL NOTES ARCH / INTERIOR ABBREVIATIONS BUILDING SUMMARY PROJECT TEAM 1. CONTRACTOR SHALL COMPLY WITH THE CURRENT "GENERAL CONDITIONS," AND BUILDING STANDARDS AS PROVIDED BY THE BUILDING OWNER. 2. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING THE WORK OF DIFFERENT TRADES. 3. DO NOT SCALE DRAWINGS. CONTACT ARCHITECT FOR ANY MISSING DIMENSIONS. 4. CONTRACTOR INITIATED CHANGES SHALL BE SUBMITTED IN WRITING TO THE OWNER AND ARCHITECT FOR APPROVAL PRIOR TO FABRICATION OR CONSTRUCTION. CHANGES SHOWN ON SHOP DRAWING ONLY WILL NOT SATISFY THIS REQUIREMENT. 5. ALL MODIFICATIONS, REQUIRING OWNER OR ARCHITECT APPROVAL WILL NOT BE VALID UNLESS AUTHORIZED IN WRITING BY OWNER AND/OR ARCHITECT. 6. WITHIN FIVE (5) BUSINESS DAYS OF START OF CONSTRUCTION, THE CONTRACTOR SHALL NOTIFY IN WRITING BOTH THE ARCHITECT AND OWNER OF ANY ITEMS WHOSE ESTIMATED DELIVERY TO THE SITE WOULD BE LATER THAN THAT REQUIRED FOR TIMELY INSTALLATION IN THE CONSTRUCTION SEQUENCE SUBSTITUTION OF ALTERNATE ITEMS WITH SHORTER LEAD TIMES, PAYMENT OF RUSH FABRICATION OR DELIVERY CHARGES OUT OF SEQUENCE INSTALLATION, OR DELAY OF INSTALLATION OPTIONS TO BE AT THE SOLE APPROVAL OF OWNER OR ARCHITECT. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL WORK AND MATERIALS IN ACCORDANCE WITH THE LATEST LOCAL BUILDING CODES AND ORDINANCES. 8. CONTRACTOR SHALL VERIFY ALL FIELD DIMENSIONS AND CONDITIONS AND SHALL REPORT ANY CONFLICTS OR QUESTIONS FOR RESOLUTION BEFORE PROCEEDING WITH THE WORK. DO NOT SCALE THE DRAWINGS. 9. THE USE OF WORD "PROVIDE" SHALL ALWAYS MEAN, "FURNISH AND INSTALL, CONNECT, OR SECURE" AS REQUIRED. 10. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS WRITTEN INSTRUCTIONS AND TRADE ASSOCIATES ACCEPTED STANDARDS. 11. CONTRACTOR SHALL PROVIDE A WRITTEN CONSTRUCTION SCHEDULE. THIS SCHEDULE SHALL INCLUDE DELIVERY LEAD TIMES OF CONSTRUCTION ITEMS, AND START AND COMPLETION DATES OF EACH PHASE. THE CONTRACTOR SHALL UPDATE AND PROVIDE SUCH SCHEDULE ON A BIWEEKLY BASIS. 12. WORK MUST BE SCHEDULED WITH THE BUILDING MANAGEMENT TO AVOID DISRUPTION TO THE TENANTS. 13. ACCESS TO AND FROM THE PROJECT SITE, SPECIAL CONDITIONS, NOISY WORK, TIMING OF WORK, INTERRUPTION OF MECHANICAL AND ELECTRICAL SERVICES, RELOCATION OF EXISTING EQUIPMENT, CASEWORK, FIXTURES, FITTINGS, ETC., MUST BE COORDINATED WITH THE BUILDING MANAGEMENT. 14. ADEQUATE CLEANUP, PROTECTION AND PLACEMENT OF ANY CEILING TILES AND/OR OTHER DISRUPTION TO THE ADJACENT TENANT IMPROVEMENTS MUST BE REPLACED BEFORE BUSINESS HOURS OF THAT TENANT IN ORDER THAT THE OCCUPANT WILL NOT BE INCONVENIENCED IN THE NORMAL CONTINUATION OF THEIR OFFICE HOURS. 15. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. THIS INCLUDES ALL AREAS ON THE PREMISES SUCH AS: COMMON HALLWAYS, FREIGHT ELEVATOR VESTIBULES, ETC. 16. SCHEDULE THE USE OF THE ELEVATOR WITH BUILDING MANAGEMENT. 17. UPON COMPLETION OF ALL CONSTRUCTION, THE CONTRACTOR SHALL SUPPLY THE LANDLORD WITH ONE SET OF "RECORD" AS -BUILT DRAWINGS. 18. ALL MATERIALS TO BE NEW UON. 19. PATCH ALL DISTURBED AND/OR DAMAGED AREAS AS REQUIRED TO ACCOMPLISH NEW WORK AND AS REQUIRED FOR FINISHED APPEARANCE. 20. GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY BACKING, BLOCKING, AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL FIXTURES, CASEWORK AND ALL OTHER ITEMS REQUIRING IT. 21. CONTRACTOR TO COORDINATE ALL FIRE ALARM WORK WITH BUILDING OWNER. 22. ALL PAINT AND FINISH MATERIAL COLORS SHALL MATCH ARCHITECT'S CONTROL SAMPLES AND REQUIRE ARCHITECT'S REVIEW PRIOR TO INSTALLATION. SUBMIT TO ARCHITECT THREE (3) COPIES FOR REVIEW. 23. CONTRACTOR SHALL FURNISH SHOP DRAWINGS FOR REVIEW ON CABINETWORK, MILLWORK AND ANY OTHER SPECIAL ITEMS REQUIRING CUSTOM SHOP FABRICATION. SUBMIT TO ARCHITECT AT LEAST THREE (3) COPIES FOR REVIEW. 24. REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS SHALL BE COMPLETELY PROVIDED AS IF DRAWN IN FULL. 25. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS WHICH ARE IN COMMON USE. THE LIST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE A COMPLETE LIST. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. ADJ AFF ALT ALUM APC - APPROX - ARCH ACT AV BLDG BOT CAB CL CLG CLR COL CONC CONF DEMO DEPT DF DIA DIFF DIM DTL DW DWG EA EL ELEC ELEV EQ EQUIP EXT FA FD FE FEC FFE FIN FLUOR FLR FO FOIC FTIC FURR GA GC GL GWB HC HDW HM HR INCL INFO INSUL LAV LF MATL MAX MDF ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM ACOUSTICAL PANEL CEILING APPROXIMATE ARCHITECTURAL ACOUSTICAL CEILING TILE AUDIO VISUAL BUILDING BOTTOM CABINET CENTER LINE CEILING CLEAR COLUMN CONCRETE CONFERENCE DEMOLITION DEPARTMENT DRINKING FOUNTAIN DIAMETER DIFFUSER DIMENSION DETAIL DISHWASHER DRAWING EACH ELEVATOR ELECTRICAL ELEVATION EQUAL EQUIPMENT EXTERIOR FIRE ALARM FLOOR DRAIN FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR ELEVATION FINISH FLUORESCENT FLOOR FACE OF FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FURNISHED BY TENANT, INSTALLED BY CONTRACTOR FURRING GAUGE GENERAL CONTRACTOR GLASS GYPSUM WALLBOARD HANDICAPPED HARDWARE HOLLOW METAL (STEEL FRAME) HOUR INCLUDED OR INCLUDING INFORMATION INSULATION LAVATORY LINEAR FOOT MATERIAL MAXIMUM MEDIUM DENSITY FIBERBOARD MECH MEZZ MFR MIN MISC MTD MTL N/A NIC NTS OC OFF OPNG OVHD P PART PERF PERIM PERP PLAM PLYWD QTY (R) RA RCP REC REF REFR REL REV RM RO - RTD - SCHED - SF - SHT - SIM - SPEC - SPKLR - SPKR SQ STD STL STOR STRL - STRUC - SYMM TBD TEL TEMP TH K TO TOS TYP UON UPS VCT VIF W/ WC WD W/O MECHANICAL MEZZANINE MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL NOT APPLICABLE NOT IN CONTRACT NOT TO SCALE ON CENTER OFFICE OPENING OVERHEAD PAINT PARTITION PERFORATED PERIMETER PERPENDICULAR PLASTIC LAMINATE PLYWOOD QUANTITY RELOCATED RETURN AIR REFLECTED CEILING PLAN RECESSED REFERENCE REFRIGERATOR RELOCATE REVISION OR REVISED ROOM ROUGH OPENING RATED SCHEDULE SQUARE FEET/FOOT SHEET SIMILAR SPECIFICATION SPRINKLER SPEAKER SQUARE STANDARD STEEL STORAGE STRUCTURAL STRUCTURAL SYMMETRICAL TO BE DETERMINED TELEPHONE OR TELECOM TEMPERED THICKNESS TOP OF TOP OF SLAB TYPICAL UNLESS OTHERWISE NOTED UNINTERRUPTED POWER SUPPLY VINYL COMPOSITION TILE VERIFY IN FIELD WITH WATER CLOSET WOOD WITHOUT REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. U017:: revisions will require a new plan submittal cni may include additional plan review fees. 1. PROJECT ADDRESS: REAL TIME STAFFING RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 101 TUKWILA, WA, 98188 2. APPLICABLE CODES & ORDINANCES: 2009 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL MECHANICAL CODE 2009 INTERNATIONAL FUEL GAS CODE 2009 INTERNATIONAL FIRE CODE 2009 WASHINGTON STATE ENERGY CODE (WAC 51-11) 2009 UNIFORM PLUMBING CODE 2009 NATIONAL FUEL GAS CODE (NFPA 54) 2008 LIQUEFIED PETROLEUM GAS CODE (NFPA 58) THE WASHINGTON CITIES ELECTRICAL CODE 2009 WASHINGTON STATE AMENDMENTS 2003 ICC/ANSI 117.1 ACCESSIBLE & USABLE BUILDINGS AND FACILITIES 3. GENERAL BUILDING DESCRIPTION: TYPE OF CONSTRUCTION:. IIB FIRE RESISTIVE SYSTEM: SPRINKLERED OCCUPANCY TYPE: 'B' OFFICE 4. FIRE RESISTIVE CONSTRUCTION REQUIREMENTS: SHAFT ENCLOSURES: 1 HOURS EXIT STAIR ENCLOSURES: 1 HOURS CORRIDORS: 1 HOUR 5. EXITS: APPROXIMATE AREA OF CONSTRUCTION: 50 SQUARE FEET TOTAL APPROXIMATE SUITE AREA: 2,546 SQUARE FEET TOTAL APPROXIMATE FLOOR AREA: 15,836 SQUARE FEET OCCUPANT LOAD FACTOR: 100/SQUARE FEET NUMBER OF TOTAL PROPOSED OCCUPANTS: 45 NUMBER OF EXITS REQUIRED: 1 MINIMUM EGRESS WIDTH REQUIRED: 3'-8" COMMON PATH OF EGRESS TRAVEL: 75'-0" 6. PROJECT DESCRIPTION: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT. WORK INCLUDES NON-STRUCTURAL DEMOLITION, NEW PARTITIONS, DOORS, AND SIDELIGHT. TENANT: REAL TIME STAFFING 16040 CHRISTENSEN ROAD, SUITE 101 TUKWILA, WA 98188 ARCHITECT/DESIGNER: BURGESS DESIGN, INC. 1326 5TH AVENUE, SUITE 500 SEATTLE, WASHINGTON 98101 TEL: 206.587.7120 FAX: 206.587.7122 ATTN: RANDY MORGAN BUILDING MANAGER: UNICO PROPERTIES 16040 CHRISTENSEN RD, STE 100 TUKWILA, WA 98188 TEL: 206.373.7137 FAX: 206.373.7135 ATTN: KATHY DOUGHERTY GENERAL CONTRACTOR: TBD PLUMBING ENGINEER: TBD - Bidder Design Build by G.C. MECHANICAL ENGINEER: TBD - Bidder Design Build by G.C. ELECTRICAL ENGINEER: TBD - Bidder Design Build by G.C. FIRE/LIFE SAFETY ENGINEER: TBD - Bidder Design Build by G.C. PLUMBING, MECHANICAL, ELECTRICAL, LIFE SAFETY PERMITS UNDER SEPARATE SUBMITTALS. CODE SUMMARY LEGAL DESCRIPTION / PARCEL NO. PARCEL NUMBER: 2523049078 LEGAL DESCRIPTION: POR GL 1 OF SEC 25-23-04 DAF BEG SW COR PARCEL 4 OF CITY OF TUKWILA SHORT PLAT NO 78 -16 -SS RECORDING NO 7906050098 TH N 00-14-00 W 210 FT TAP OF CURVE TH NLY 104.72 FT ALG ARC OF NON TANGENT CURVE TO LFT RAD 40 FT RADIUS PT BEARING N 00-14-00 W THRU C/A 150-00-00 TAP OF REV CURVE TH NLY 41.89 FT ALG ARC OF TANGENT CURVE TO RGT RAD 40 FT THRU C/A 60-00-00 TAP OF TANGENCY TH N 00-14-00 W 121.31 FT TH N 89-46-00 E 115.50 FT TH N 00-14-00 W 8.50 FT TH N 89-46-00 E 98.50 FT TH N 00-14-00 W 8.50 FT TH N 89-46-00 E 24.61 FT TH S 60-14-00 E 17.19 FT TH N 29-46-00 E 49.36 FT TAP OF CURVE TH NLY 52.96 FT ALG ARC OF TANGENT CURVE TO LFT RAD 320 FT THRU C/A 09-28-59 TAP ON SD CURVE TH S 77-75-04 E 30.59 FT TH S 12-34-56 W 28 FT TH S 77-25-04 E 105.59 FT TH S 31-16-45 W 11.09 FT TH S 34-31-52 W 60.54 FT TH S 30-51-21 W 61.78 FT TH S 13-16-05 W 53.94 FT TH S 15-57-27 W 51.82 FT TH S 13-48-40 W 54.33 FT TH S 00-38-22 E 62.39 FT TH S 00-18-55 W 41.21 FT TH S 07-39-16 E 53.77 FT TH S 18-27-46 E 56.37 FT TH S 27-57-17 E 8.24 FT TH N 89-47-00 W 343.34 FT TO POB AKA REVISED LOT 3 OF CITY OF TUKWILA BDRY LN ADJ NO 81-40 BLA RECORDING NO 8112160540 REVISING CITY OF TUKWILA BDRY LN ADJ NO 81-1 BLA RECORDING NO 8102050389 TOTAL OCCUPANT LOAD 47 OCCUPANTS OPEN OFFICE 862 S.F. OCC. LOAD: 100 S.F/OCC.= 9 OCC OFFICE 134 S.F. OCC. LOAD: 100 S.F/OCC.= 1 OCC EXISTING CONDITION CONFERENCE 278 S.F. OCC. LOAD: 15 S.F/OCC.= 18 OCC 148 S.F. 160 S.F. OCC. LOAD: OCC. LOAD: 100 300 S.F/OCC.= S.F/OCC.= 1 OCC 1 OCC 34 OCCUPANTS EXISTING THROUGH THIS DOOR 13 OCCUPANTS EXISTING THROUGH THIS DOOR STREET MAP DRAWING INDEX \ DRAWING ISSUED r') CD M M co GENERAL X X G.0.0 COVER SHEET / PROJECT INFORMATION X X G.0.1 PROJECT NOTES X X ARCHITECTURAL / INTERIORS A.2A.1 DEMOLITION PLAN CONSTRUCTION PLAN ANDOVER PARK W STRANDER BLVD DEFINITIONS AND DIMENSIONS KEY PLAN / FLOOR PLATE - 1":25' SYMBOLS L D SECTION REFERENCE SYMBOL ELEVATION REFERENCE SYMBOL U DETAIL ID SHEET NO. DETAIL REFERENCE SYMBOL COLUMN AND/OR GRID LINE SYMBOL DIMENSION LINE: O 20'-0" O L ANGLE (§ AT CENTERLINE INDICATES FINISHED SURFACES TO ALIGN DRAWING TITLE BAR DETAIL IDENTIFICATION DRAWING TITLE GRAPHICAL SCALE FLOOR ELEVATION SYMBOLS 92'-O" +1'-0" NOMINAL FLOOR ELEVATION HEIGHT (ABOVE/BELOW) BUILDING SPACE / ROOM ID OFFICE SPACE NAME 1127 -�-- SPACE NUMBER DOOR SYMBOL DOCUMENT SHEET SYMBOL -0-- KEYED SHEET NOTES GLAZING SYMBOL -0-- REVISION NUMBER A. DEFINITIONS: 1. "TYPICAL" OR "TYP" INDICATES IDENTICAL COMPLETE SYSTEM FOR THE CONDITION NOTED. 2. "SIMILAR" OR "SIM." INDICATES COMPLETE SYSTEM AND COMPONENTS COMPARABLE TO THE CHARACTERISTICS FOR THE CONDITION NOTED. 3. "AS REQUIRED" INDICATES CONTRACTOR SHALL PROVIDE COMPONENTS REQUIRED TO COMPLETE THE NOTED SYSTEM AS INDICATED IN THE PROJECT DOCUMENTS. 4. "ALIGN" INDICATES ACCURATELY PROVIDE FINISH FACES OF MATERIALS IN STRAIGHT, TRUE, AND PLUMB RELATION ADJACENT MATERIALS. 5. "CLEAR" INDICATES CRITICAL DIMENSION AND SHALL SET PRECEDENT FOR LAYOUT OF PARTITIONS. B. DIMENSIONS: 1. DIMENSIONS ARE INDICATED TO THE FACE OF FINISHED SURFACE AT ALL NEW AND EXISTING CONSTRUCTION, CENTER OF COLUMNS OR GRID LINES UNLESS OTHERWISE NOTED 2. ALIGNMENT OF PARTITIONS AND FINISHES AS SCHEDULED SHALL BE STRAIGHT, TRUE & PLUMB. DIMENSIONAL LAYOUT SHALL BE IN THE FOLLOWING PRIORITY ORDER. A. STRUCTURAL DRAWINGS B. LARGE SCALE DETAILS C. SMALL SCALE DETAILS D. ENLARGED PLANS AND SECTIONS E. FLOOR PLANS 3. MINIMUM DIMENSIONS FOR ACCESSIBILITY CLEARANCES AND BUILDING CODE REQUIREMENTS SHALL BE MAINTAINED. 4. FLOOR ELEVATIONS ARE INDICATED AT THE FACE OF THE STRUCTURAL SLAB, UNLESS OTHERWISE NOTED. 5. VERTICAL DIMENSIONS ARE INDICATED FROM THE FLOOR ELEVATION TO FACE OF FINISHED MATERIAL, UNLESS NOTED ABOVE FINISH FLOOR - "AFF". 6. CEILING HEIGHTS ARE INDICATED FROM THE FLOOR ELEVATION TO THE FACE OF SUSPENDED ACOUSTIC CEILING GRID OR FACE OF FINISH MATERIAL FOR OTHER CEILING TYPES, UNLESS OTHERWISE NOTED. 7. DOCUMENTS ARE DRAWN DIAGRAMATICALLY, AND SCALED DIMENSIONS ARE APPROXIMATE. DIMENSIONS SHALL INDICATE REQUIRED SIZE, CLEARANCES, AND RELATIONSHIPS ARE INDICATED BY DIMENSIONS AS NOTED. • REAL TIME STAFFING RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 101 TUKWILA, WA, 98188 FIRST FLOOR EXISTING TENANT LONGEST COMMON PATH OF EGRESS TRAVEL: 96' i EXITING HAS BEEN EXIT IMPROVED FROM TENANT'S PREVIOUS CONDITIONS. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 242013 City of Tukwila UILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 3 2013 PERMIT CENTER Fi Y it No. -X10 review approval is subjectto errors and mission of corn; ion documents does not authorize art;• .:. on of any adopted ode or ordnance. Receipt of Ltiproved Cod ard►' ,t 3. Is By/di; City Of 1UkwlIa BUILDING DIVISION UPJ Tenant: REAL TIME STAFFING RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 101 TUKWILA, WA 98188 A Tenant Improvement for: UNICO PROPERTIES RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 100 TUKWILA, WA 98188 el burgess design I interiors Q architecture 1326 Fifth Avenue. Suite 400. Seattle Washington 98101 T: (206) 587.7120 F: (206) 587.7122 All reproduction & intellectual property rights reserved c 2013 Approved by: Date: CONSTRUCTION WORK SHALL NOT PROCEED UNTIL THE BUILDING OWNER / REPRESENTATIVE AND BUILDING TENANT HAVE GIVEN THEIR APPROVAL TO THESE CONSTRUCTION DOCUMENTS. APPROVAL BY THESE PARTIES SHALL BE INTERPRETED AS APPROVAL OF DRAWINGS FOR CONTENT, FINISH SELECTIONS, SCOPE OF WORK, AND ALL DIMENSIONS REGARDED BY EITHER PARTY AS BEING NECESSARY TO THEIR OPERATIONS, USE OF THE SPACE, FURNISHINGS, AND TENANT EQUIPMENT AND FURNITURE INSTALLATIONS. CONSTRUCTION AND/OR INITIATION OF CONSTRUCTION, AUTHORIZED BY THE BUILDING OWNER FROM THESE CONSTRUCTION DOCUMENTS, SHALL BE INTERPRETED BY THE DESIGNER AS APPROVAL IN FULL OF THESE CONSTRUCTION DOCUMENTS BY BOTH THE BUILDING OWNER / REPRESENTATIVE AND THE TENANT. Professional seal TERED ITECT RANDALL ALAN MORGAN STATE OF WASHINGTON No. Issue Description Date REVIEW SET 6.7.13 PERMIT SET 6.13.13 Drawn by: TS Project N. ager: RM Project No: 13-8206-00 COVER SHEET / PROJECT INFORMATION Original drawing is 24" x 36". Scale entities accordingly if reduced G.0.0 PROJECT NOTES 1. THESE PROJECT NOTES ARE GENERIC IN NATURE. CONTRACTORS INSTRUCTIONS FOR CONSTRUCTION ADMINISTRATION MAY VARY BASED ON THE CONTRACT BETWEEN BUILDING MANAGEMENT AND TENANT. VERIFY WITH BUILDING MANAGEMENT ALL CONSTRUCTION REQUIREMENTS AND CONSTRUCTION ADMINISTRATION RESPONSIBILITIES. THE DESIGNER MAY NOT HAVE CONSTRUCTION ADMINISTRATION OBLIGATIONS. 2. PLUMBING, ELECTRICAL, MECHANICAL & LIFE SAFETY SHALL BE PERFORMED UNDER THE DESIGN/BUILD CONTRACT. ALL WORK SHALL BE TO CODE. ANY INFORMATION ON THESE DRAWINGS ARE FOR REFERENCE AND SCHEMATIC DESIGN ONLY. CONTRACTOR IS RESPONSIBLE FOR ALL ASPECTS OF THE DESIGN. VERIFY. REQUIREMENTS OF BUILDING MANAGEMENT AND TENANT. REVIEW OF SHOP DRAWINGS, IF APPROPRIATE, IS FOR AESTHETIC REASONS ONLY. 3. VERIFY BUILDING STANDARDS WITH BUILDING MANAGEMENT WHEN WORKING IN SUITES WITH NON BUILDING STANDARD ELEMENTS. VERIFY PREFERRED DETAILING OF THESE ELEMENTS WITH BUILDING MANAGEMENT. 4. VERIFY ALL RULES, GENERAL CONDITIONS AND SPECIALIZED BUILDING REQUIREMENTS WITH THE BUILDING MANAGEMENT. 5. VERIFY LEED REQUIREMENTS WITH BUILDING MANAGEMENT. DMSION I - GENERAL CONDITIONS 01010 SUMMARY OF WORK 1. GENERAL DESCRIPTION OF THE PROJECT: NON-STRUCTURAL INTERIOR TENANT IMPROVEMENT OF A COMMERCIAL OFFICE SUITE, UON. 2. WHERE NO BUILDING STANDARDS EXIST FOR MATERIALS CALLED OUT AS "BUILDING STANDARD" ON THE PLANS, THE CONTRACTOR SHALL SO ADVISE BURGESS DESIGN WITHIN TEN (10) DAYS OF THE CONTRACTOR'S RECEIPT OF THE PLANS SO THAT BURGESS DESIGN MAY MAKE ALTERNATE SELECTIONS. 3. CONTRACTOR SHALL VERIFY ALL REQUIREMENTS OF EXACT SIZE AND QUANTITY OF EQUIPMENT FURNISHED BY THE TENANT, INCLUDING REQUIREMENTS FOR MECHANICAL AND ELECTRICAL SERVICES, AND IS RESPONSIBLE FOR ALL ROUGH -IN CONNECTIONS. EACH SUBCONTRACTOR IS RESPONSIBLE FOR ANY DAMAGE TO ADJACENT WORK AND SHALL REPAIR SAID DAMAGE AT THEIR OWN EXPENSE. 4. FIRE/EMERGENCY SYSTEMS INCLUDE, BUT ARE NOT LIMITED TO, SPRINKLER MODIFICATIONS, FIRE EXTINGUISHER PLACEMENT, AUDIBLE ALARMS, SMOKE AND HEAT DETECTORS, STROBES, AND EXIT SIGN PLACEMENT. 5. ALL DESIGN BUILD INFRASTRUCTURE SHALL BE UNDER A SEPARATE PERMIT BY CONTRACTOR. 6. WORK NOT INCLUDED: CONTRACTOR SHALL PROVIDE THE FOLLOWING ITEMS DESCRIBED IN THE SPECIFICATIONS AND SHOWN ON THE PLANS EXCEPT FOR THE ITEMS INDICATED "N.I.C." (NOT IN CONTRACT), SUCH AS TELEPHONE AND DATA CABLES, OFFICE FURNITURE, EQUIPMENT AND MOBILE KITCHEN APPLIANCES. 7. CONTRACTOR TO PROVIDE ALL FIRE/EMERGENCY SYSTEMS AS REQUIRED BY ALL APPLICABLE CODES. FIRE/EMERGENCY SYSTEMS INCLUDE BUT NOT LIMITED TO SPRINKLER MODIFICATIONS, FIRE EXTINGUISHERS, AUDIBLE ALARMS, STROBES, SPRINKLERS, SMOKE AND HEAT DETECTORS, AND EXIT SIGNS. 8. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, AND SHALL BE EQUIPPED WITH PANIC HARDWARE WHERE REQUIRED AND INDICATED. 9. ANY MATERIAL USED IN CONSTRUCTION SHALL MEET CURRENT FLAME CODE REGULATIONS. 10. ALL ELECTRICAL, PLUMBING AND MECHANICAL MATERIAL INSTALLATIONS SHALL COMPLY WITH THE BUILDING SHELL STANDARD SPECIFICATIONS. 11. THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY WITH THE REQUIREMENTS OF CONTRACT DOCUMENTS, AND WILL BE HELD RESPONSIBLE FOR PROPER ESTABLISHMENT AND MAINTENANCE OF ALL LINES AND DIMENSIONS. BEFORE DOING AND WORK, THE GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND CONDITIONS AT THE SITE AND NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES. 12. THE CONTRACTORS SHALL USE DIMENSIONS ONLY. DO NOT SCALE PLANS. ALL DIMENSIONS ARE TO FINISHED FACE UNLESS OTHERWISE NOTED. 13. MATERIALS: ALL MANUFACTURED ARTICLES, MATERIALS, AND EQUIPMENT SHALL BE APPLIED AS RECOMMENDED BY MANUFACTURERS. ALL LIKE MATERIALS USED SHALL BE OF THE SAME MANUFACTURER AND QUALITY UNLESS OTHERWISE SPECIFIED. ALL MATERIAL, EQUIPMENT AND FIXTURES SHALL BE CODE WORTHY WITH ALL PROPER JURISDICTIONAL APPROVALS. DMSION II - SITE WORK 02050 - DEMOLITION 1. FURNISH ALL LABOR, MATERIALS AND EQUIPMENT AS REQUIRED TO COMPLETE THE DEMOLITION AND REMOVAL OF ALL ITEMS LOCATED IN THE CONSTRUCTION AREAS. UPON COMPLETION OF ALL DEMOLITION WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN. 2. DEMOLITION OF TELEPHONES, ELECTRICAL, VOICE/DATA AND PANELS ARE TO BE REMOVED BACK TO ORIGINATING SOURCE. DEMOLITION OF CORES AND RELATED CABLING TO BE REMOVED FROM TENANT SPACES BELOW. 3. DURING THE REMOVAL OF ANY ENVIRONMENTALLY HAZARDOUS MATERIALS, PROTECTION GUIDELINES SHOULD BE STRICTLY FOLLOWED BY CODE OR LOCAL GOVERNING AUTHORITY. 4. ALL EXISTING CONSTRUCTION ITEMS THAT INTERFERE WITH THE CONSTRUCTION NEGOTIATED BY THE PRICING PLAN / SPACE PLAN WITH WORK LETTER SHALL BE REMOVED, RELOCATED, OR KEPT FLUSH IN CEILING, WALL, OR FLOOR AS REQUIRED. 5. ALL DAMAGED, ALTERED OR REWORKED AREAS SHALL BE PATCHED AS REQUIRED AND FINISHED TO MATCH EXISTING ADJACENT AREAS OR AS SPECIFIED TO PROVIDE A "LIKE -NEW FINISH". 6. CONTRACTOR SHALL PROVIDE PLASTIC SHEETING OR OTHER APPROPRIATE BARRIER TO CONTROL DUST AND DEBRIS SUCH THAT IT DOES NOT AFFECT AREAS OUTSIDE THE AREA OF WORK. DMSO VI - ARCHITECTURAL CARPENTRY AND CASEWORK 06100 - ROUGH CARPENTRY 1. ROUGH CARPENTRY TO INCLUDE ANY WOOD STUDS, FURRING, BLOCKING, ROUGH FRAMING, WOOD CURBS, BUCKS, NAILERS, BACKING, FIXTURE FRAMING, EQUIPMENT SUPPORTS, ETC. AS DETAILED. 06200 - FINISH CARPENTRY 1. FINISH CARPENTRY TO INCLUDE INSTALLATION OF ALL FIXTURES AND ASSOCIATED TRIMS, HARDWARE AND NOSINGS. 2. PROVIDE INTERIOR DOOR AND SIDELIGHT FRAMES AS SCHEDULED. 06400 - ARCHITECTURAL WOODWORK AND CASEWORK 1. CABINET CONSTRUCTION: COMPLY WITH THE A.W.I. ARCHITECTURAL WOODWORK QUALITY STANDARDS FOR CUSTOM GRADE WORK. CABINETS SHALL BE FLUSH CONSTRUCTION. 2. PROVIDE PARTICLE BOARD, MED. DENSITY, WEIGHING <40 LB./CU. FT., AT LEAST 3/4" THICK. 3. CABINET HARDWARE: FULL EXTENSION DRAWER GLIDES, STAINLESS STEEL CABINET PULLS, US32D FINISH, AND CONCEALED DOOR HINGES, SHELF HARDWARE AND OTHER REQUIRED ITEMS, UON IN ELEVATIONS / DETAILS, OR PER BUILDING STANDARD. 4. PLASTIC LAMINATE: HIGH-PRESSURE DECORATIVE LAMINATE SELECTED FROM WILSONART, NEVAMAR, AND FORMICA, UON. LAMINATE TO BE GENERAL-PURPOSE GRADE .050" HORIZONTAL AND .030" VERTICAL. 5. INTERIOR CABINET SURFACES & SHELVES TO BE OF PREFINISHED BOARD WITH POLYESTER OVERLAY, UON. 6. SHELF EDGING TO BE P -LAM, UON. 7. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. DMSION VIII - DOORS AND WINDOWS 08210 - WOOD DOORS 1. PROVIDE AND INSTALL INTERIOR SUITE DOORS AS INDICATED ON DRAWINGS. 2. DOOR SCHEDULE SPECIFIES FINISH (BOTH SIDES OF DOOR) AND FRAME, UON. 3. DOORS SHALL BE PRE -MACHINED FOR HARDWARE PER HARDWARE SCHEDULE. 4. SUBMIT SHOP DRAWING SUBMITTALS FOR ARCHITECT REVIEW. . CONTRACTOR SHALL REVIEW SUITE FOR DOOR STYLE CHANGES AND VERIFY WITH ARCHITECT AND BUILDING MANAGEMENT THE DOOR STYLE TO MATCH IF A VARIATION IS PRESENT. 08710 - FINISH HARDWARE 1. FINISH AND SPECIALTY HARDWARE INCLUDES ALL ACCESSORIES, TOOLS, AND FASTENERS REQUIRED FOR HARDWARE INSTALLATION AND MAINTENANCE. ITEMS NOT SPECIFICALLY MENTIONED, BUT NECESSARY TO COMPLETE THE WORK, SHALL BE FURNISHED MATCHING IN QUALITY AND FINISH OF SPECIFIED IN SIMILAR LOCATIONS. 2. PROVIDE ALL HARDWARE AS SPECIFIED PER THE HARDWARE SCHEDULE. 3. ALL LOCK SETS SHALL CONFORM TO THE BUILDING'S GRAND MASTER KEYING SYSTEMS. PROVIDE TWO (2) KEYS FOR EACH LOCK AND TWO (2) MASTER KEYS FOR THE SUITE. ALL KEYS TO BE TAGGED WITH ROOM NUMBERS. CONFIRMQ UANTITY WITH BUILDING MANAGEMENT. 4. SUBMIT HARDWARE SCHEDULE WITH CATALOGUE CUT SHEETS FOR ARCHITECT REVIEW. 5. ALL DOORS SHALL HAVE A MINIMUM OF 1-1/2 PAIR OF BUTT HINGES, ONE LATCHSET OR LOCK SET, AND ONE DOOR STOP TO MEET ACCESSIBILITY REQUIREMENTS. 6. ALL HARDWARE SHALL BE COMMERCIAL GRADE AND RATED AT REQUIRED ASSEMBLIES. 7. PROVIDE CLOSERS PER HARDWARE SCHEDULE AND AT ALL RATED ASSEMBLIES. 8. ALL HARDWARE SHALL MATCH BUILDING STANDARD IN STYLE AND FINISH. 9. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER INSTALLATION AND OPERATION. 10. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION MADE. 11. PROVIDE PROPER SMOKE GASKETS AT RATED ASSEMBLIES. 12. MATCH BUILDING STANDARD SPECIFICATIONS AND FINISHES. 13. THE FOLLOWING UL LISTINGS ARE REQUIRED ON THE FOLLOWING HARDWARE: PANIC HARDWARE - UL #305 FIRE EXIT HARDWARE - UL #106 & UL #305 ELECTROMAGNETIC LOCK HARDWARE - UL # FWAX-S-A-6635 THE CRASH BAR MUST BE AT LEAST 1/2 OF THE DOOR WIDTH AND OPEN FORCE NO MORE THAN 15 LBS. VERIFY WITH BUILDING STANDARD & MANAGEMENT AND INFORM ARCHITECT IF BUILDING STANDARD DOESN'T COMPLY. 08810 - GLASS 1. ALL GLASS AT SIDELIGHTS AND DOORS SHALL BE 1/4" TEMPERED SAFETY GLAZING, UON. 2. CONTRACTOR SHALL VERIFY GLASS THICKNESS IS APPROPRIATE. FOR DIMENSIONS AND SPANS. 3. THIS PROJECT CONTAINS GLAZING THAT WILL BE SUBJECT TO FEDERAL GLAZING STANDARDS. GLAZING SUBCONTRACTOR SHALL BE RESPONSIBLE FOR ADHERENCE TO THE REQUIREMENTS. IF GLAZING SUBCONTRACTOR FINDS ANYTHING IN THE DOCUMENTS NOT IN COMPLIANCE WITH THE STANDARD, THEY SHALL BRING DISCREPANCIES TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. RATED GLASS (CERAMIC) RELITE SHALL BE PREMIUM POLISHED FINISH. DMSION IX FINISHES 09250 GYPSUM DRYWALL AND METAL STUDS 1. INCLUDE NECESSARY MATERIALS, LABOR AND ACCESSORIES FOR THE INSTALLATION OF ALL PARTITIONS AS SHOWN IN THE PLANS. 2. "WALL SURFACES" MEAN ALL VERTICAL SURFACES INCLUDING COLUMNS WHERE EXPOSED, CONVECTOR OR RADIATOR ENCLOSURES, FASCIAS, RETURNS, PLYWOOD BACKBOARDS, ETC. 3. ALL PARTITION HEADS SHALL MATCH BUILDING STANDARD, UON. 4. WALLS SHOWN ALIGNED WITH BASE BUILDING STRUCTURE SHALL BE FLUSH AND SMOOTH WITH BASE BUILDING STRUCTURE, UON. 5. SEISMIC BRACING: PROVIDE SEISMIC BRACING AS REQUIRED PER THE LATEST BUILDING CODES TO THE PARTITION HEADS AND CEILING GRID. 6. FRAMING STUDS: GALVANIZED STEEL STUDS PER CONSTRUCTION PLANS. PROVIDE WITH SHEET METAL BACKING WITHIN ALL WALLS RECEIVING CASEWORK (CABINETS, BOOKSHELVES, ETC.). VERIFY STUD SIZE MATCHES DOOR FRAMES IN STOCK IF APPLICABLE. 7. CONTRACTOR SHALL PROVIDE AND LOCATE ACCESS PANELS AS REQUIRED AFTER INSTALLATION OF MECHANICAL DUCTS, PLUMBING, AND ELECTRICAL WORK. FIRE RATE AS REQUIRED. 8. ALL DRYWALL TO BE 5/8" TYPE "X" UNLESS OTHERWISE NOTED. PROVIDE "M/R" TYPE DRYWALL WHERE REQUIRED BY CODE AND AT ALL TOILET ROOMS, AND BEHIND CERAMIC TILES, UON. 9. INSTALL CORNER BEADS AT ALL EXTERNAL CORNERS. INSTALL METAL EDGE TRIM WHENEVER EDGE OF GYPSUM BOARD WOULD OTHERWISE BE EXPOSED OR SEMI -EXPOSED. 10. PRIOR TO RECEIVING FINISH, ALL SURFACES SHALL BE PROPERLY PREPARED AS REQUIRED TO RECEIVE FINAL FINISHING AS SPECIFIED. 11. EXTEND ALL SOFFIT FRAMING TO STRUCTURE ABOVE. PROVIDE STRUCTURAL DIAGONAL BRACING AS NECESSARY. 12. PROVIDE FRAMING FOR SUSPENDED CEILING WITH SEISMIC BRACING IN ACCORDANCE WITH REQUIREMENTS OF APPLICABLE CODES AND AS SHOWN ON DRAWINGS. 13. USE ACOUSTICAL SEALANT AROUND ALL PIPES, DUCTS, CONDUIT, OUTLETS, SWITCHES, ETC. ON BOTH SIDES OF CROSSING/PENETRATING WALLS WITH ACOUSTICAL INSULATION. PENETRATIONS OF FIRE -RATED WALLS SHALL BE PROTECTED BY APPLICABLE FIRE -RATED ASSEMBLIES AND MATERIALS. 14. FIRE AND SMOKE SEPARATION ASSEMBLIES SHALL BE MARKED AS REQUIRED IN IBC SECTION 703.6. 09500 - CEILING SUSPENSION SYSTEMS. 1. PROVIDE NEW CEILING TILE, CEILING GRID AND ALL ACCESSORIES AS REQUIRED TO INSTALL SUSPENDED ACOUSTICAL CEILINGS AS INDICATED ON DRAWINGS. 2. PROVIDE SEISMIC BRACING AS REQUIRED BY CODE AT NEW CEILING WORK ONLY. VERIFY WITH BUILDING MANAGEMENT IF EXISTING CONDITIONS ARE SEISMICALLY BRACED OR PROVIDE PER CODE. 3. COORDINATE WORK WITH OTHER TRADES HAVING WORK IN THE CEILING AND THE TELEPHONE AND DATA CABLE COMPANIES WHEREVER THEIR RESPECTIVE WORK IS CONTIGUOUS. 4. PROVIDE CUTOUTS AND OTHER SPECIAL PROVISIONS IN ACOUSTICAL WORK AS REQUIRED FOR LIGHTING FIXTURES, REGISTERS, DIFFUSERS, SPRINKLERS, AND OTHER INSERTED ITEMS. 5. ALL CUTOUTS SHALL BE CENTERED WITHIN ACOUSTIC CEILING TILE, UON. 6. ALL MATERIALS SHALL HAVE CLASS 1 FLAME SPREAD RATING AND BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATION AND CODES. 7. ALL JOINTS IN THE TILE FIELD SHALL BE SQUARE, LEVEL AND PERFECTLY ALIGNED WITH EACH OTHER. 8. INSTALLED SUSPENDED CEILINGS TO BE LEVEL WITHIN A TOLERANCE OF 1/8" IN 12'-0". ANCHOR AS REQUIRED. 9. IN AREAS OF ALTERATIONS CONTRACTOR SHALL MATCH CONDITIONS AND MAKE EVERY EFFORT TO ALIGN, LEVEL AND MATCH NEW CEILING TO OLD. CONTRACTOR SHALL REVIEW ALL CEILINGS UPON COMMENCEMENT OF THE PROJECT AND INFORM THE BUILDING MANAGEMENT OF ANY DISCONTINUITIES IN THE CEILING WITHIN 10 DAYS. 10. ADJUST PARTITION HEAD DETAIL TO MATCH EXISTING CEILING CONDITIONS IF NECESSARY. 09530- ACOUSTICAL TREATMENT 1. PROVIDE ACOUSTICAL INSULATION BETWEEN FRAMING STUDS AND EXTENDING TWO FEET ON EACH SIDE OF PARTITION HEAD ABOVE CEILINGS FOR ALL WALLS NOTED PER PLANS. 2. NEW DEMISING WALL CONSTRUCTION TO HAVE SOUND BATT INSULATION BETWEEN FRAMING STUDS AND TWO FEET OF INSULATION ON EITHER SIDE OF THE PARTITION HEAD ABOVE CEILING GRID, UON. 09650 - RESILIENT FLOORING 1. PROVIDE VCT, SHEET LINOLEUM, SHEET VINYL AND RUBBER BASE AS INDICATED IN DRAWINGS. COLOR AND MANUFACTURER PER FINISH SCHEDULE. 2. PROVIDE RUBBER -REDUCING STRIPS IN COLOR TO MATCH SPECIFIED BASE. REDUCING STRIPS TO OCCUR AT ALL AREAS OF FLOOR MATERIAL TRANSITION. 3. BASE TO BE INSTALLED IN LONGEST AVAILABLE LENGTH WITH NO PIECE LESS THAN 12". NO JOINTS AT OUTSIDE CORNERS OR WITHIN 6" OF CORNERS. 4. PATCH, LEVEL AND PREPARE SUB FLOORING WITH CEMENTITIOUS UNDERLAY PER MFR'S WRITTEN INSTRUCTIONS IN AREAS TO RECEIVE NEW FLOORING. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 5. GENERAL CONTRACTOR SHALL APPLY FLOOR WAX TO NEW FLOORING AREAS PER MANUFACTURERS SPECIFICATION, UON. 6. UNLESS SPECIFIED ALL RUBBER BASE SHALL BE COVED BASE. 09680 CARPET 1. PROVIDE AND INSTALL COMMERCIAL GRADE CARPET AS INDICATED IN DRAWINGS. 2. PREPARE SUB FLOOR WITH LIGHT WEIGHT CONCRETE UNDERLAY WHERE REQUIRED TO PROVIDE APPROVED SUBSTRATE. MAX. ALLOWABLE TOLERANCE = 1/4" OVER 10'. 3. PROVIDE SEAMING DIAGRAMS FOR ARCHITECT'S REVIEW. 09900 - PAINTING AND STAIN 1. UNLESS OTHERWISE NOTED, PRIME ALL GWB WALL SURFACES AND PAINT WITH MINIMUM OF TWO (2) FINISH COATS OF BENJAMIN MOORE EGGSHELL FINISH LATEX PAINT OR APPROVED EQUAL, UON. PROVIDE FOR NUMBER OF PAINT COLORS AS INDICATED IN DRAWINGS. 2. FINISH DOORS, DOOR FRAMES, AND SIDELIGHT FRAMES AS INDICATED IN DRAWINGS. A) PAINTED WOODWORK TO BE FINISHED WITH ONE (1) COAT PRIMER AND TWO (2) FINISH COATS. B) SEALED WOODWORK TO BE STAINED PER FINISH SCHEDULE AND SEALED WITH A COMMERCIAL GRADE CLEAR SATIN VARNISH. 3. PAINT FOR THE LIGHT SURFACES TO CONFORM TO THE REQUIREMENTS OF THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3-B "CUSTOM" (1) COAT PRIMER AND TWO (2) FINISH COATS. GRADE LIGHT COLOR PAINT FINISH ON GYPSUM BOARD SURFACES. 4. PAINT FOR THE DARK SURFACES TO CONFORM TO THE REQUIREMENTS FOR THE "ARCHITECTURAL SPECIFICATIONS MANUAL" (AWS) FOR PAINT SYSTEMS. LATEX PAINT: AWS SYSTEM 3-B "CUSTOM" (1) COAT PRIMER AND TWO (2) FINISH COATS. GRADE DEEP TONE PAINT FINISH ON GYPSUM BOARD SURFACES. 5. UPON COMPLETION OF WORK, REMOVE EXCESS PAINT, STAIN, VARNISH, ADHESIVE, CAULK, ETC. FROM ALL OTHER SURFACES THAT WERE NOT SPECIFIED TO RECEIVE SAME. 6. TOUCH-UP AND PATCH SURFACES AS REQUIRED AFTER THE COMPLETION OF WORK BY OTHER TRADES. 7. WHERE COLUMNS OCCUR IN AREAS SCHEDULED TO BE FINISHED, THEY SHALL RECEIVE THE SAME FINISH AS THE ROOM, UON. 8. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING OF EXISTING SURFACES). 9. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE APPLYING FINISH. 10. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH. 11. SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH FINE SANDPAPER TO PRODUCE SMOOTH FINISH. 12. MAKE FINISH WORK UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR COLORS SHARP AND CLEAN WITHOUT OVERLAPPING. DMSION XII - FURNISHINGS 12500 - WINDOW TREATMENT 1. ALL EXISTING INTERIOR AND PERIMETER MINI BLINDS TO BE BAGGED AND CLEANED TO LIKE -NEW CONDITION. 2. ALL PERIMETER GLAZING TO RECEIVE BLINDS AS INDICATED IN DRAWINGS. COORDINATE WITH BUILDING MANAGEMENT. MATCH EXISTING CONDITIONS UON. 3. ALL INTERIOR SIDELIGHTS TO RECEIVE 1" MINI -BLINDS WHERE INDICATED IN DRAWINGS. 4. PROVIDE SAMPLE AND CUT SHEET TO ARCHITECT FOR REVIEW. 12900 - SIGNAGE 1. PROVIDE AND INSTALL ALL CODE REQUIRED SIGNAGE. DMSION XV - MECHANICAL 15400 - PLUMBING 1. PROVIDE SUPPLY, WASTE AND VENT LINES, VALVES, FITTINGS, ETC. REQUIRED FOR KITCHEN SINKS, DISHWASHER, REFRIGERATOR, AIR CONDITIONING UNIT(S), VENDING MACHINES, COFFEE MAKER, WATER HEATERS, ETC. 2. ALL FIXTURE INSTALLATIONS SHALL CONFORM TO THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE NEW PLUMBING FIXTURES AS SPECIFIED PER DRAWINGS, OR PER BUILDING STANDARD, UON. 4. PROVIDE HOT AND COLD WATER TO SINKS/DISHWASHERS IF APPLICABLE. 5. ALL NEW WATER HEATERS ARE TO BE INSTALLED WITH DRIP PAN CONNECTED TO WASTE LINE. VERIFY LOCATIONS WITH BUILDING MANAGEMENT AND INSPECTORS. 6. ALL PLUMBING FIXTURES ARE TO BE INSTALLED TO MEET CURRENT GOVERNING LOCAL AND FEDERAL CODES. 7. CONTRACTOR SHALL PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 8. VERIFY WATER SUPPLY & SEWER DRAIN CAPACITY FOR ENTIRE BUILDING WILL MEET NEW CAPACITY WHEN NEW RESTROOMS ARE ADDED TO BUILDING. 15500 - FIRE PROTECTION 1. ALTER OR INSTALL FIRE PROTECTION SYSTEM PER BUILDING STANDARD, LOCAL REGULATIONS AND ORDINANCES. 2. PROVIDE ALL EMERGENCY LIGHTING, EXIT SIGNS, FIRE ALARM SPEAKERS, STROBES AND BELLS AS REQUIRED BY CODE. DESIGN AND INSTALL THE SAME IN COMPLIANCE WITH THE AMERICANS WITH DISABILITIES ACT. 3. PROVIDE SPRINKLERS, FIRE RATED DOORS AND FRAMES, FIRE EXTINGUISHERS, ETC. AS REQUIRED BY APPLICABLE LOCAL CODES AND LAWS. 4. FIRE EXTINGUISHERS SHALL BE BY UNDERWRITER'S LABORATORY 2A-10BC 5 -LB, MULTIPURPOSE EXTINGUISHER WITH SQUEEZE -.TYPE HANDLE AND FLEXIBLE DISCHARGE HOSE WITH VISIBLE PRESSURE GAUGE, UON. 5. FIRE EXTINGUISHERS SHALL BE INSTALLED PER BUILDING STANDARD REQUIREMENTS, UON. VERIFY LOCATION WITH FIRE MARSHALL WHEN REQUIRED BY CODE, PROVIDE 1 WALL MOUNT TYPE IN EACH SERVER ROOM OR LABORATORY. 6. DESIGN BUILD FIRE PROTECTION DRAWINGS INDICATE: A. LAYOUT, LOCATION, AND SIZE OF SPRINKLER LINES AND HEADS. B. PRESSURE REQUIREMENTS. C. SPRINKLER HEAD SPECIFICATIONS. D. LOCATION OF FIRE PROTECTION RISERS AND WALL HYDRANTS 7. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. `°INCLUDE HORNS AND STROBES. 8. ALL SPRINKLER HEADS SHALL BE CENTERED IN ACOUSTICAL CEILING TILE, UON. 9. USE OF NFPA 13 QUICK RESPONSE HEADS MAY BE REQUIRED. CONTRACTOR SHALL VERIFY EXTENT OF QUICK RESPONSE HEADS BY CITY FOR THIS PROJECT. 15800 - HEATING VENTILATING AND AIR CONDITIONING 1. PROVIDE BUILDING STANDARD HVAC SYSTEM WITH ALL MATERIALS, LABOR AND ACCESSORIES FOR COMPLETE OPERATION OF SYSTEM. CONTRACTOR TO BALANCE HVAC SYSTEM AS REQUIRED. 2. DESIGN BUILD MECHANICAL ENGINEERING DRAWINGS INDICATE: A. DUCTS, AIR MOVEMENT. REQUIREMENTS, & SIZES OF GRILLES & REGISTERS. 3. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 4. HVAC CONTRACTOR TO CLEAN, REPAIR OR REPLACE SOILED OR DAMAGED HVAC GRILLS, FILTERS AND THERMOSTATS. 5: RE -ZONE, ALTER OR SEPARATE HVAC AS NECESSARY AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 16000 - ELECTRICAL AND TELECOMMUNICATIONS 1. REUSE EXISTING ELECTRICAL AND DATA AS APPROPRIATE TO MEET THE TENANT'S REQUIREMENTS. REPLACE OUTLET COVER PLATES TO MATCH NEW FINISH IF APPLICABLE. 2. PROVIDE ALL WORK, EQUIPMENT AND LABOR FOR A COMPLETE AND OPERABLE ELECTRICAL SYSTEM. PROVIDE ELECTRICAL OUTLETS PER POWER AND DATA PLAN. 3. PROVIDE MUD RING FOR DATA AND COMMUNICATION AS SHOWN ON THE POWER AND DATA PLAN. EACH MUD RING TO HAVE A MINIMUM NUMBER OF WIRE PULLS AS INDICATED ON DRAWINGS. COORDINATE DATA CABLE CONFIGURATION WITH THE TENANT. 4. ALL OUTLETS AND MUD RINGS TO BE LOCATED AT 18" AFF TO THE CENTER LINE, UON. 5. WHERE MULTIPLE DEVISES OCCUR IN A SINGLE LOCATION, ALL DEVICES SHALL BE GANGED UON. 6. ALL ELECTRICAL OUTLETS WITHIN THE CODE REQUIRED DISTANCE FROM A SINK SHALL BE ON A GROUND FAULT INTERRUPTED CIRCUIT. 7. ALL WIRING DEVICES: SHALL BE BUILDING STANDARD EXCEPT: "ISOLATED GROUND" OUTLETS SHALL BE ORANGE, "HOSPITAL GRADE ISOLATED GROUND" OUTLETS SHALL BE ORANGE WITH A GREEN DOT, "EMERGENCY" OUTLETS SHALL BE RED, AND "DEDICATED" OUTLETS FOR "CLEAN CIRCUIT" FIXTURES SHALL BE GRAY (UNLESS BUILDING STANDARD DICTATES OTHERWISE). ALL COVER PLATES SHALL BE BUILDING STANDARD FINISH, UON. VERIFY WITH BUILDING MANAGEMENT. 8. PROVIDE SEPARATE CIRCUITS FOR TENANT'S EQUIPMENT (INCLUDING THE TELEPHONE SWITCH, COPIERS, COMPUTERS, ETC.) WHEN NOTED ON THE CONSTRUCTION DOCUMENTS. 9. COORDINATE SCHEDULE WITH FURNITURE VENDOR FOR THE USE OF ELECTRICIANS DURING THE INSTALLATION OF TENANT'S NEW FURNITURE. 10. ALL ELECTRICAL WIRING, TELEPHONE AND COMPUTER CABLING, AND CONDUIT SHALL BE CONCEALED IN FLOORS, WALLS, OR CEILINGS. CABLING FOR VOICE AND DATA TO BE PROVIDED BY TENANT'S VENDORS AND SHALL BE COORDINATED BY THE BUILDING MANAGER. 11. THE CONTRACTOR IS TO COORDINATE WITH THE TENANTS SUPPLIED FURNITURE SYSTEMS TO INCLUDE BUT NOT LIMITED TO: ELECTRICAL AND DATA WIRING LOCATIONS, J -BOX LOCATIONS, CONNECTIONS AND WALL MOUNTED REQUIREMENTS. 12. THE CONTRACTOR IS TO VERIFY EXISTING ABANDONED CORE DRILL LOCATIONS AND FILL AS REQUIRED WITH MATERIAL TO MEET CURRENT FLAME SPREAD REGULATIONS. LOCATIONS TO BE PREPARED TO RECEIVE NEW FLOOR FINISH AS REQUIRED. FLOOR SHALL BE LEFT FLUSH. 13. ARCHITECTURAL DRAWINGS INDICATE LOCATION ONLY OF DEVICES SHOWN. SWITCHING AND CIRCUITING SHALL BE INDICATED ON SEPARATE ELECTRICAL ENGINEERING AS -BUILT DRAWINGS AND SHALL MEET OWNER'S GUIDELINES: 14. ALL TELEPHONE, ELECTRICAL, COMMUNICATION AND SECURITY WORK SHALL BE COMPLETED IN ACCORDANCE WITH ALL APPLICABLE CODES. 15. DRAWINGS INDICATE ALL DIMENSIONS TO CENTERLINE OF TELEPHONE, ELECTRICAL, AND COMMUNICATION COVER PLATE. OUTLETS SHOWN GROUPED TOGETHER ON PLAN SHALL BE SET TO A MINIMUM DIMENSION BETWEEN EACH DEVICE. 16. BACK-TO-BACK OUTLETS ARE NOT PERMITTED. OFFSET OUTLETS THE MINIMUM DIMENSION REQUIRED FOR ACOUSTICAL CONTROL 17. LOCATION OF ALL WALL MOUNTED POWER AND DATA DEVICES SHALL BE FIELD REVIEWED BY THE TENANT BEFORE INSTALLATION. 18. ELECTRICAL ENGINEER TO PROVIDE DESIGN/BUILD PACKAGE TO ARCHITECT FOR REVIEW PRIOR TO INSTALLATION. 19. THE LAYOUT DIAGRAMS COORDINATE LOCATION OF POWER & DATA DEVICES. REFER TO DESIGN/BUILD DOCUMENTS FOR SCOPE, TECHNICAL LAYOUT AND SPECIFICATIONS FOR EACH DISCIPLINE. 20. ARCHITECTS DOCUMENTS INDICATE LOCATION AND RELATIONSHIP OF DEVICES. COORDINATE EXACT LOCATION WITH FURNITURE VENDOR. 21. COORDINATE POWER/DATA, FIRE SAFETY DEVICES & LIGHT FIXTURE MOUNTING LOCATIONS WITH INTERIOR ELEVATIONS, SYSTEM FURNITURE, FINISHES & CASEWORK. 22. PROVIDE EXTENSION RINGS AND MOUNTING ACCESSORIES WHERE REQUIRED FOR POWER/DATA DEVICES AND LIGHT FIXTURES. COORDINATE WITH INTERIOR FINISHES AND CASEWORK. 23. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. INCLUDE GRILLS AND THERMOSTATS. 24. RECIRCUIT, ALTER OR SEPARATE ELECTRICAL AND VOICE SYSTEM AS NECESSARY AND AS DIRECTED BY BUILDING MANAGEMENT FOR ALTERED SUITES. 16500 - LIGHTING 1. LOCATION OF SWITCHES SHALL BE SHOWN ON THE REFLECTED CEILING PLAN. ALL SWITCHES SHALL BE MOUNTED AT A MAXIMUM HEIGHT OF 48" A.F.F. TO MEET THE LATEST ACCESSIBILITY CODES AND REGULATIONS. 2. WHERE MULTIPLE SWITCHES OCCUR IN A SINGLE LOCATION, ALL SWITCHES SHALL BE GANGED UON. 0 3. WHEN WORKING IN PUBLIC CORRIDOR VERIFY SWITCHING REQUIREMENTS WITH BUILDING MANAGEMENT. 4. VERIFY WITH BUILDING MANAGEMENT SEPARATION OF SUITE SWITCHING WHEN DEMISING CONFIGURATIONS CHANGE. 5. DOWN LIGHTS SHOWN IN THE CENTER OF CEILING TILE WITHOUT DIMENSIONS ARE TO BE LOCATED IN THE CENTER OF CEILING TILE OR CENTER OF 2X2 PORTION OF 2X4 SECOND LOOK TEGULAR TILE. UON. 6. REUSE ALL EXISTING BUILDING STANDARD FLUORESCENT FIXTURES AS NEEDED PER DESIGN LAYOUT AND TO MEET LOCAL ENERGY CODE COMPLIANCE. VERIFY OR PROVIDE NEW LAMPS AND REPLACE FAULTY BALLASTS. 7. PERMIT DRAWINGS TO BE REVIEWED AND APPROVED IN WRITING BY LANDLORD PRIOR TO COMMENCEMENT OF WORK. 8. ALL OFFICE AREAS LESS THAN 300 SQ. FT. ENCLOSED BY WALLS OR CEILING -HEIGHT PARTITIONS, AND ALL MEETING AND CONFERENCE ROOMS, SHALL BE EQUIPPED WITH OCCUPANCY SENSORS, PER CODE. 9. DESIGN BUILD ELECTRICAL ENGINEERING DRAWINGS INDICATE: A. CIRCUITING AND WIRING OF LIGHT FIXTURES, AND SWITCHES. B. LIFE SAFETY EQUIPMENT. C. LOCATION OF REQUIRED EMERGENCY LIGHT FIXTURES. D. LIGHT FIXTURE SPECIFICATIONS 10. CONTRACTOR TO PROVIDE INSTALLATION DESIGN DOCUMENTS TO ARCHITECT AND BUILDING OWNER FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. 11. CONTRACTOR SHALL RE -CIRCUIT AND RE -SWITCH ALL ASPECTS OF TENANT SUITE AND ADJOINING SUITES AS NECESSARY TO FULLY SEPARATE TENANT SUITE FROM OTHERS, AND PROVIDE NEW CORRIDOR, HALLWAY AND OPEN OFFICE SWITCHES AS NEEDED. 12. VERIFY SWITCHING WITH TENANT AND BUILDING MANAGEMENT. VERIFY APPROVED ENERGY CODE REQUIREMENTS OR ENERGY MANAGEMENT SYSTEM AS PART OF THE DESIGN BUILD CONTRACT. 13. PROVIDE, ALTER OR VERIFY ALL EMERGENCY EXIT LIGHTING AND ACCESS PATHWAY LIGHTING AS DIRECTED BY EXISTING CONDITIONS AND CODE REQUIREMENTS. 14. EXIT SIGNS SHALL HAVE UL #924. Tenant: REAL TIME STAFFING RIVERVIEW PLAZA, BUILDING 16040 CHRISTENSEN ROAD, SUITE 101 TUKWILA, WA 98188 A Tenant Improvement for: UNICO PROPERTIES RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 100 TUKWILA, WA 98188 e• V ' burgess design interiors Q architecture 1326 Fifth Avenue . Suite 400. Seat le Washington 98101 T: (206) 587.7120 F: (206) 587.7122 All reproduction & intellectual property rights reserved c 2013 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 2 4 2013 City of Tukwila BUILDING DIVISION Professional seal No. Issue Description Date REVIEW SET 6.7.13 PERMIT SET 6.13.13 RECEIVED CITY OF TUKWILA JUN 132013 PERMIT CENTER Drawn by: TS Project No: 13-8206-00 Project Manager: RM PROJECT NOTES Original drawing is 24" x 36". Scale entities accordingly if reduced G.0.1 DEMOLITION PLAN 0 8' 16' 24' 1/8" = 1'_ 0" OPEN OFFICE RECEPTION a ltt CONFERENCE cc CONSTRUCTION PLAN 0 8' 16' 24' SYMBOL LEGEND r___ EXISTING CONSTRUCTION TO BE REMOVED EXISTING CONSTRUCTION TO REMAIN NEW INTERIOR PARTI11ON CONSTRUCTION, PER DETAIL L/A.9.1 FULL HEIGHT SIDELITE PARTIAL HEIGHT SIDELITE 0 u� FRAMELESS SIDELITE GENERAL DEMOLITION NOTES 1. REFER TO CONSTRUCTION PLAN AND CEILING PLAN FOR EXTENT OF DEMOLITION. 2. SAVE AND STORE ALL LIGHT FIXTURES, EXIT SIGNS, DOORS & HARDWARE FOR RE—USE, UON. 3. SAVE ALL EXISTING PLUMBING FIXTURES FOR RE—USE, UON. 4. REMOVE ALL TELEPHONE, ELECTRICAL, AND DATA OUTLETS, FIXTURES, PANELS, ETC FROM ALL DEMOLISHED PARTITIONS. REMOVE ALL CORRESPONDING CABLES, CONDUIT, WIRING, ETC. ALL THE WAY BACK TO THE ORIGINATING SOURCE, UON. GENERAL CONSTRUCTION NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. GENERAL CONTRACTOR TO FIELD VERIFY ALL EXISTING CONDMONS PRIOR TO COMMENCEMENT OF WORK. 3. ALL INTERIOR PARTITION, PENETRATIONS, AND OTHER OPENINGS IN THE BUILDING SHELL SHALL BE SEALED, GASKETED, OR WEATHER STRIPPED AS REQUIRED TO MEET PARTI11ON RATINGS. 4. WHERE PARTITION LAYOUT INTERSECTS EXISTING SHELL/CORE GYPSUM BOARD, REMOVE EXISTING CORNER BEADS AND OTHER ACCESSORIES, ALIGN FACE OF PAR1TnONS, TAPE & SAND SMOOTH FOR NEW FINISH. 5. PROVIDE PARTITION ANCHOR BRACKETS FOR ALL CASEWORK, FIXTURES, EQUIPMENT, & DEVICES MOUNTED ON OR ATTACHED TO PARTITIONS. 6. PART1ONS ARE TO BE BUILDING STANDARD FLOOR TO CEILING PARTITIONS, UON. SEE TYPICAL WALL DETAIL SHEET FOR MORE INFORMATION. 7. DOORS AND CASED OPENINGS WITHOUT DIMENSIONS OR DETAILS ARE TO BE LOCATED 4* FROM ADJACENT WALL OR MATCH EXISTING SUITE STANDARD. 8. NO CHANGE TO CEILING OR LIGHTING. 9. NO CHANGE TO ELECTRICAL 10. NO CHANGE TO FINISHES. KEYED SHEET NOTES O1 REMOVE PORTION OF EXISTING PARTITION FOR NEW DOOR. O REMOVE PORTION OF EXISTING PARTITION FOR NEW RELITE. <I UPPER CASEWORK TO REMAIN. LIGHTING NOTES 1. VERIFY OR PROVIDE EGRESS ILLUMINATION PER IBC 1006 TO EXISTING LIGHTING LAYOUT. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THIS SYSTEM UNDER THE DESIGN BUILD CONTRACT. VERIFY WITH BUILDING MANAGEMENT'S EXISTING SYSTEM AND PROVIDE FULL COMPLIANCE TO NEW TENANT SPACE. 2. THE CONTRACTOR UNDER THE DESIGN BUILD CONTRACT SHALL PROVIDE A MINIMUM OF 1 FOOT—CANDLE PER SQUARE FOOT, AS MEASURED FROM 18" FROM ABOVE THE FINISHED FLOOR, FOR EMERGENCY EGRESS LIGHTING CONTINUOUSLY ALONG THE ENTIRE LENGTH OF THE PATH OF TRAVEL REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 3 2013 PERMIT CENTER Tenant: REAL TIME STAFFING RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 101 TUKWILA, WA 98188 A Tenant Improvement for: UNICO PROPERTIES RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 100 TUKWILA, WA 98188 burgess design interiors O architecture 1326 Fifth Avenue . Suite 400. Seattle Washington 98101 T: (206) 587.7120 F: (206) 587.7122 All reproduction & intellectual property rights reserved c 2013 Professional seal 8021 ISTERED ITECT RANDALL ALAN MORGAN STATE OF WASHINGTON No. Issue Description Date REVIEW SET 6.7.13 PERMIT SET 6.13.13 Drawn by: TS Project Manager: Project No: 13-8206-00 RM DEMOLITION PLAN CONSTRUCTION PLAN Original drawing is 24" x 36". Scale entities accordingly if reduced A.2A.1 BOTTOM OF STRUCTURE 1 1 1/4" \ /\ 2"X2"X12" MIN. LEG AT STRUCTURE — ATTACH W/2 POWDER DRIVEN FASTENERS PER BRACE OR OTHER APPROVED METHOD PLENUM HEIGHT OF 5'-0" OR LESS 2 1/2"x25 GA METAL STUD BRACING 0 8'-0" OC TO STRUCTURE DIRECTION ALTERNATE. PARTITIONS PERPENDICULAR TO PARTITION ACT AS BRACE PLENUM OF 5'—O" TO 1O'—O" SHALL USE NESTED OR BACK TO BACK 3-1/2" 25 GA. STEEL STUDS. ABOVE 1O'-0" OR PLENUM. CONTACT ARCHITECT FOR ADDITIONAL INFORMATION. MAX PARTI11ON WEIGHT 15Ibs./P.S.F. SUSPENDED CEILING AS SCHEDULED VERIFY B/S HEAD CONDITION 3/8" CONT. FOAM SOUND ISOLATION TAPE TAPEABLE MET. TOP TRACK ATTACHED TO BRACING W/2 SELF—TAPPING SM. SCREWS 0 48"oc, AND 3/4" PIPE SLEEVES 2 1/2" X 25 GA (18 MILS) METAL STUDS 0 24" OC, TO 10'-7" MAX. HEIGHT. 1 LAYER 5/8" TYPE "X" GYP. BD. EA. SIDE OF METAL STUDS ATTACHED W/ #6 SCREWS 0 12" O.C. MAX. POWDER DRIVEN FASTENER 0 24 OC MET. RUNNER TRACK SEALANT CONCRETE SLAB NON -RATED FLOOR TO CEILING PARTITION 0" 4" 8" 1 2" 3" = V -o" DOOR & HARDWARE GENERAL NOTES 1. SEE HARDWARE SPECIFICATIONS FOR HARDWARE, TYPES AND INSTALLATION. 2. DOOR WIDTH & HEIGHT ARE NOMINAL DIMENSIONS FROM JAMB TO JAMB AND FINISH FLOOR TO BOTTOM OF FRAME 0 HEAD. REFER TO SPECIFICATIONS FOR CLEARANCES. 3. DOUBLE DOOR NOMINAL WIDTH INDICATES 2 DOOR LEAVES OF EQUAL WIDTH, U.O.N. 4. DOOR CONSTRUCTION SHALL PROVIDE ATTACHMENT OF ALL HARDWARE WITHOUT THROUGH — BOLTS. 5. DOOR / HARDWARE SHALL COMPLY WITH ALL APPLICABLE IBC OR SBC & ACCESSIBILITY REQUIREMENTS. 6. ALL HARDWARE SHALL BE BUILDING STANDARD, UON. HARDWARE GROUP HARDWARE GROUP HARDWARE REMARKS GROUP 1 SINGLE, ENTRY LOCKSET RATED 1 ENTRY FUNCTION LOCKSET 4 HINGES DOOR CLOSER 1 WALL—MOUNTED DOOR STOP GROUP 2 SINGLE, PASSAGE LATCHSET NON—RATED PASSAGE LATCHSET HINGES 1 FLOOR -MOUNTED DOOR STOP DOOR SCHEDULE CC w W CO CC O C] DOOR NOMINAL WIDTH W Q2 5 HARDWARE GROUP 101 3'-O" M.E. A 2 WD 105 3'—O" M.E. A 1 WD 20 DOOR TYPES SUITE STANDARD WOOD [FRAME SUITE STANDARD FLUSHI S.C. WOOD DOOR M.E. = MATCH ALL EXISTING CONDMONS SIDELIGHT/GLAZING SCHEDULE CC w CO w C] U, SIDELIGHT = C—, w J V HEADER HEIGHT SIDELIGHT TYPE Z Z W FRAME MATERIAL G1 M.E. M.E. 3'-O" A 1/4" TEMPERED WD SIDELIGHT/GLAZING TYPES w WIDTH A SUITE STANDARD WOOD FRAME GLAZING AS SCHEDULED 1) vs. ./t M.E. = MATCH ALL EXISTING CONDITIONS REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 1 3 2013 PERMIT CENTER Tenant: REAL TIME STAFFING RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 101 TUKWILA, WA 98188 A Tenant Improvement for: UNICO PROPERTIES RIVERVIEW PLAZA, BUILDING I 16040 CHRISTENSEN ROAD, SUITE 100 TUKWILA, WA 98188 burgess design interiors O architecture 1326 Fifth Avenue . Suite 400. Seat le Washington 98101 T: (206) 587.7120 F: (206) 587.7122 All reproduction & intellectual property rights reserved c 2013 Professional seal 8021 SRED ECT RA , ALL ALAN MORGAN STATE OF WASHINGTON No. Issue Description Date REVIEW SET 6.7.13 PERMIT SET 6.13.13 Drawn by: TS Project Manager: RM Project No: 13-8206-00 DOOR SCHEDULE / SIDELIGHT SCHEDULE / DETAILS Original drawing is 24" x 36". Scale entities accordingly if reduced A.9.1