Loading...
HomeMy WebLinkAboutPermit M13-020 - REIT MANAGEMENT - ALTERATIONREIT MANAGEMENT 4225 S 150 ST EXPIRED 08-04-13 M13-020 City Qt --Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2523049008 Address: 617 INDUSTRY DR TUKW Project Name: REIT MANAGEMENT Permit Number: M13-020 Issue Date: 02/05/2013 Permit Expires On: 08/04/2013 Owner: Name: BLUE DOG PROPERTIES TRUST Address: C/O THOMSON REUTERS PTS , PO BOX 847 92018 Contact Person: Name: Address: Email: Contractor: Name: Address: JOHN WARE 109 WASHINGTON BL. SUITE B , ALGONA WA 98001 JOHN W @FIVESTARMEC H. C OM Phone: 206-786-8278 FIVE STAR MECHANICAL Phone: 253-852-8284 109 WASHINGTON BLVD STE B , ALGONA WA 98001 Contractor License No: FIVESM*010JT Expiration Date: 05/01/2014 DESCRIPTION OF WORK: REMOVE (8) REPLACE (1) HVAC UNIT Value of Mechanical: $9,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied 'n th, Mc Fees Collected: $293.81 International Mechanical Code Edition: 2009 Date: 09- d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Date: J /� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. we, non Prinfn*h M_nc_9!N 4 PERMIT CONDITIONS Permit No. M13-020 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Readily accessible access to roof mounted equipment is required. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Structrual Observations in accordance with I.B.C. Section 1709 is required. At the conclusion of the work included in the permit, the structural observer shall submit to the Building Official a written statement that the site visits have been made and identify any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. 7: All wood to remain in placed concrete shall be treated wood. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 11: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 12: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 13: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 14: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 15: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 16: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 17: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. don: IMC -4/10 M13-020 Printed: 02-05-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. VI I3 -D2 Project No. Date Application Accepted: Date Application Expires: �-�—i 3 --1-1)-"t (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: -2 King Co Assessor's Tax No.: 2% 5230 (ifoog Suite Number: Floor: Tenant Name: New Tenant: ❑ Yes 14. No PROPERTY OWNER Name— Name: 1 I L_p locr ` e -ry( e rd�k i 1 Address: Twa 9J'e�J � � ae,��Sis City: I 4\11.0h S - State:, f611A lip: ova CONTACT PERSON — person receiving all project communication Name— W ct.i�— Address: 1 0,1 ,S L� Inn -Stw,l). City: h1.96) St te: J14,1_ Zipt/ Phone: 2.e. o_ 8s2 _g 92 %R � 5 Fax:4).57__g 2.,_ Email:' CLin-tAi 6) g-Ve - 41/tQC4- CC MECHANICAL CONTRACTOR INFORMATION Company Name: ,,, cj es l�'l Address: t o Wc. AI.- ti \)1 St44 1'`\ �n•�-State: City: i \,3 01/49A w li_Zip: qgi_ ._ , Phone: aS3-B5 805ax: X53 85a� 5 fContr Reg No.: i .1= s7,./I ,l fxp Date: �i U fJI fr H�7 �((( Y Tukwila Business License No.: Rus Q, 7 57� �k.J (( O� I. Valuation of project (contractor's bid price): $ ' j' OZTO ql 600,00 Describe the scope of work in detail: Puft.-44).e_ g f Use: Fuel Type: a. GC -- O 1� g 1/ C tit Yl,.i 7L Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Electric 0 Gas Other: H:Wpphcauorts\Forms-Applications On Line \201 I Appltcattore\Mechanical Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signatu R A . ORIZED AGENT: Print Name: -\"AE. Day Telephone: kl City Mailing Address:1,GS to 64-4-- 'Rom H:\Applications\Fortes-Applications On Line\201 I Appltcaeorta Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Date: OS/3 PZ‘1,9C g2 78 11-- Ro( State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049008 Address: 617 INDUSTRY DR TUKW Suite No: Applicant: REIT MANAGEMENT RECEIPT Permit Number: M13-020 Status: PENDING Applied Date: 01/22/2013 Issue Date: Receipt No.: R13-00493 Initials: WER User ID: 1655 Payment Amount: $293.81 Payment Date: 01/22/2013 10:50 AM Balance: $0.00 Payee: JOHN E WARE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 004730 ACCOUNT ITEM LIST: Description 293.81 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 235.05 000.345.830 58.76 Total: $293.81 .Inn• DencineAR rhin+o,7• MA9_9MZ r SEPARATE PERMIT REQUIRED FOR: Mechanical lectrical Plumbing as Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 4 2013 ila VISION City o BUILDIN FILE COPY Permit No. M ;---02-0 Plan review approval is subject to errors and omiss ons. pproval of construction documents does not authc: i:3 thlr v olation of any adopted code or ordinance. Roci pt of approved Field C9py and ► is aolcnowiedged: Date2 -6---47 City Of Tukwila BUILDING DIVISION x'113- p2o RECEIVED CITY OF TUKWILA JAN 2 2 2013 PERMIT CENTER 0 4.. • a 169 91 2-3/41 3-7/16 [81 3] 9-15/16 [252 4] 21 9/16 [547 7] 9 15/16 -- 1252 41 SUPPLY 15-15/16 [404.81 w OUTDOOR COIL HAI) OUTLET 3/7/0" 122.2) DEEP LEFT SIDE VIEW X. 3-5/8 FOP110NAL 1• �� RETURN [•'�1 AIR OPEN INF' 125 411 [92 11 UNIT ELECTRICAL CHARACTERISTICS UNIT Y/T. UNIT HEIGHT INIMM CENTER OF GRAVITY IN/MM LB KG "A" X Y 2 48VLI-/N)A24[040/060130 208/230-1-60 330 149.6 42-1/8 1010 22-13/16 579.4 15-5/76 388.9 15-11/16 398.5 487/1.1-/N)A301040/060113/510 208/230-1, 208/230-3-60 .142._ 155 0 44-1/8 1121 22-13/16 579.4 15-5/16 388 9 15-13/16 401 6 48VL(-/N)A361060/090113/510 208/230-1, 208/230-3-60 316 170.4 46-1/8 1172 22-13/16 579.4 15-5/16 388.9 16-5/8 422.3 48VL(-/N1A36(060/090)60 460.3-60 390 176.8 46-1/8 1172 22-13/16 579.4 15-5/16 388.9 16-5/8 422.3 UNITS VOLTAGE CORIER WEIGHT LB/KG •1' '2• '3' "4" 4001.(-/N1A241040/060)30 208/230 49.5 22.5 66.0 29.9 98.9 1 44.9 115.4 52.4 48V11-/N)A301040/060113/5)0 208/230 51.3 23 3 68.4 31.0 102.51 46.5 119.6 54.3 4896(-/N)A36(060/090113/510 208/230 56.4 25.6 75.2 34.1 112.7 51.2 131.5 59 1 48V1A-/N)A361060/090)60 460 56.4 25.6 15.2 34.1 121.7 55.3 136.5 62 0 3-3/16 [81 01 6 [152 4] El 1 INDOOR COIL OUTDOOR COIL TOP VIEW 11111 47 [1193 81 COMPRESSOR. PANEL LOUVER PANEL ===-= 4.1/2 1114 31 ELECTRICAL ACCESS PANEL 4-7/8 1123.8] CONTROL ENTRY NOTE ALL TABLE DATA RELEVANT FOR ALL FACTORY INSTALLED OPTIONS EXCEPT ECONOMIZER 1-1/8" [28 61 DIA K. POWER ENTRY 7/8" [22 2] DIA. HOLE G 48 3/16 11224 01 1 00 BLOWER PANEL FRONT VIEW 14-5/16 "2" [36.6) 19-15/16 [50 4) 15-5/8 139 91 10-3/16 [258.8) 2-1/16 [52 4] 1-13/16 --7 [46 01 REOLARED CLEARANCES TO CONBUST®LE MATL TOP OF UNIT. DUCT SIDE OF UNIT SIDE OPPOSITE DUCTS. BOTTOM OF UNIT FLUE PANEL ... NEC. REOUIRED CLEARANCES. BETWEEN UNITS, POWER ENTRY SIDE UNIT AND UNGROUNDED SURFACES, POWER ENTRY SIDE. UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SURFACES, POWER ENTRY SIDE . .. . REONRED CLEARANCE FOR OPERATION AND SERVICING INCHES [MMI 14 [355 61 2 [50 81 14 [355 61 1/2 [12 7] . 36 [914 41 INCHES [MM) 42 [1066 8] 36 [914 0] .42 [1066.8] INCHES IMM) FVAF. COIL ACCESS SIDE .. .. .. . .. . 36 [914 01 POWER ENTRY SIDE 42 [1066 8] IEYCEPT FOR NEC REOUIREMENTS) UNIT TOP . . 48 (1219 21 SIDE OPPOSITE DUCTS. .. .... 36 [914 0] DUCT PANEL .. 12 [304 8)' 'MINIMUM DISTANCES:IF UNIT IS PLACED LESS THAN 12 1304 81 FROM WALL SYSTEM, THEN SYSTEM PERFORMANCE MAYBE COMPROMISED 3/16 1/2. 112.11 N.P T [4.8) GAS ENTRY RIGHT SIDE VIEW DIMENSIONS IN I] ARE IN NM LOUVER PANEL = 4.===CFS 15.7/8 [403 2] SUPPLY DUCT OPENING 6-9/16 [166 71 RETURN DUCT OPENING 0 f 0 B 1 3-7/16- [87.31 9-7/8 1250 8) 21 5/6 9 1/8 [540 3) [250 8) REAR VIEW 48VL 500191 REV 3. 0 9£-KV-'IA8f - SNOISNHLAJIQ ZINfl REVIEWED FOR CODE COMPLIANCE APPROVED FEB 0 4 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 2 2 2013 48VL-A PERMIT CENTER v u�c g l a� COMMORER MODEL DEIL o TCW OCT OOA0 OL Po 4GQL =Th s document is customer property and is to remain with this unit. Piease return to service information o pact upon completion of work. PRODUCT MCT SIPC Coro(/ TO©C.7s MODEL 8TC030C100A RATED Volts/Ph/Hz 200-230/1/60 A.R.I. RATING Ratings (Cooling) 0 BTUH Indoor Airflow (CFM) Power Input (KW) EER/SEER (BTU/Watt-Hr.) Noise Rating No. 0 29200 1000 3 6' 8.10/9 15 8.2 MODEL OUTDOOR FAN — Type No Used—Dia (in.) Type Drive — No. Speeds CFM C 0.0 in. w.g. O ; 140. Motors—HP Motor Speed R.P.M Volts/Ph/Hz F.L. Amps — L.R. Amps BTC030C100A Propeller 1-20 Direct —1 2300 —1/3 1075 200-230/1/60 1.9-4.1 POWER CONNS.—V/Ph/Hz Min. Brch. Cir. Ampacity O Fuse Size — Max. (Amos) Fuse Size — Recmd. (Amps) 200-230/1/60 21.9 35 35 COMPRESSOR No. Used — No. Speeds Volts/Ph/Hz R.L Amps — L.R. Amps Brch. Cir. Selec. Cur. Amps Climatuff" 1—I 230/1/60 13.8 — 58 14.' OUTDOOR COIL — Type Rows / F.P.I. Face Area (sq tt.) Tube Size (in.) Plate Fin 4/ 15 5 73 3/8 INDOOR FAN — Type Dia. x Width (in.) No. Used Drive / Speeds (No.) CFM vs. in. w.g. OO No. Motors — HP Motor Speed P.P.M. Volts/Ph/ Hz F.L. Amps — L R. Amps Centrifugal 10 x 9 1 Direct / 2 See Fan Pert. Table 1 — 1/4 1075 200-230/1/60 2.2 — 2.7 FILTER—Furnished? Type Recommended Lo Vel. (No. - Size - Thk ) Hi Vel. (No. - Size - Thk.) Nc 20x25-1 in INDOOR COIL —Type Rows / F.P.I. Face Area (sq. ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (ir.) Plate Fin 4/12 3 44 3/8 Expansion Valve 3/4 NPT REFRIGERANT Charge (lbs. of R-22) 7 lbs. 0 oz. DIMENSIONS Crated (in.) HxWxD 30-5/8 x 33-3 /8 x 46 WEIGHT Shipping (lbs.) / Net (lbs.) 306 / 0 Rated in accordance with A.R.I. Standard 240. '18 A.R.I. Standard 270. O R ttdjpac vrA).1 SAFETY 0 'MOVE N IS VID- G ADEQUATE BACKGROUNDS ACD GROUN S OF OR USE BY D EC - OFTOOGSL EQUOPGAMT OPTIONAL EQUIPMENT FOR OUTDOOR UNITS Indoor Thermostats — Horizontal, Heat/Cool only w/Manual Switchover AY28X92 Vertical, Cool only w/Fan Switch . AY28X104 Vertical. Heat/Cool w/Manual Switchover AY28Xt05 Evaporator Defrost Control Kit (For Cooling Units) — Needed for Cooling Operation Between 55° and 40° AY28X79 Outdoor Thermostat Kit — Includes Thermostat AY28X125 and Mtg. Brkt. — for 46°F. to -10°F. (Adjustable) BAY28X125A SUPPLEMENTARY HEATERS BAY96X259C — 208/240V, 1 Ph, 60 Hz, 1.8/2.4 KW, 6100/8200 Nom. BTUH BAY96X260C — 208/240V, 1 Ph, 60 Hz, 3.614 8 KW. 12300/16400 Nom. BTUH BAY96X261C — 208/240V, 1 Ph, 60 Hz, 4.33/5.76 KW, 14800/19700 Norm BTUH BAY96X262C — 208/240V, 1 Ph. 60 Hz, 6.12/8.16 KW, 20900/27900 Nom. BTUH BAY96X263C — 208/240V, 1 Ph. 60 Hz, 7.93/10.56 KW, 27000/36100 Nom. BTUH BAY96X264C — 208/240V. 1 Ph, 60 Hz, 8.65/11.52 KW, 29500/39300 Nom. BTUH BAY96X2929 — 208/240V, 1 Ph, 60 Hz, 12.98/ 17.28 KW, 44300/59000 Nom. BTUH BAY96X293A — 208/240V, 3 Ph, 60 Hz, 12.98/17.28 KW, 44300/59000 Nom. BTUH O Calculated in accordance with Natl. Electric Code. Suitable for use with HACR circuit breakers or fuses. O Standard Air — Dry Coil — Outdoor. O Standard Air — Wet Coil — Indoor. © Rated in accordance with D.O.E. test procedure. r] Power supply voltage limits Voltage Limits Max I.D. Temp Max 0.0. Temp. Low High DB/WB DB 207 — 254 95,''71 115 196 — 207(a) 95/71 105 187 — 196(b) 95/71 100 (a) 0.1). fan must be on high speed. Indoor airflow must not exceed 450 CFM /TON. Start kit required. (b) O.D. fan must be on high speed. Indoor airflow must not exceed 450 CFM/TON. Start kit must be used. (c) Capacity reduction for unit operation at 208 volts vs. 230 volts is 1% approximately. AL AND MECHANICAL EXPERIENCE. ANY ATTEMPT TO REPAIR A CENTRAL AIR CONDITIONING PRODUCT MAY RESULT IN PERSONAL INJURY AND/OR PROPERTY DAM- AGE. THE MANUFACTURER OR SELLER CANNOT BE RE- SPONSIBLE FOR THE INTERPRETATION OF THIS INFOR- MATION, NOR CAN IT ASSUME ANY LIABILITY IN CONNEC- TION WITH ITS USE. RECONNECT Gxdd GROU09 DN((n rEVOOES ALL PARTS OF THIS PRODUCT CAPABLE OF CONDUCTING ELECTRICAL CURRENT ARE GROUNDED. IF GROUNDING WIRES, SCREWS. STRAPS, CLIPS, NUTS OR WASHERS USED TO COMPLETE A PATH TO GROUND ARE REMOVED FOR SERVICE, THEY MUST BE RETURNED TO THEIR ORIGINAL POSITION AND PROPERLY FASTENED. (RECEIVED MTV OF TUKWILA DISCONNECT POWER BEFORE; S _ R-VVICING P.I. 9/84 The Trane Company Deal, Products Group • Troup Highway• Tyler, TX 75711 PHYSICAL DATA UNIT SIZE 24040 24060 30040 33880 36060 36090 42060 42090 2 2 2-1/2 2-1/2 '- 3 3 3-1/2 3-1/2 NOMINAL COOLING CAPACITY (ton) NOMINAL HEATING INPUT (Btu/hr) 40,000 60,000 40,000 60,000 60,000 90,000 60,000 90,000 SHIPPING WEIGHT** lb. SHIPPING WEIGHT** (kg) 337 153 337 153 349 158 349 158 383 174 383 174 472 214 472 214 COMPRESSORS Quantity Scroll 1 REFRIGERANT (R -410A) Quantity lb. Quantity (kg) 6.0 2.7 6.0 2.7 5.6 2.5 5.6 2.5 9.5 4.3 9.5 4.3 8.8 4.0 8.8 4.0 REFRIGERANT METERING DEVICE TXV OUTDOOR COIL Rows...Fins/in. Face Area (sq ft) 1..21 11.9 1..21 11.9 1...21 13.6 1..21 13.6 2...21 15.4 2...21 15.4 2..21 13.6 2...21 13.6 OUTDOOR FAN Nominal CFM Diameter in. Diameter (mm) Motor Hp (Rpm) 2500 24 609.6 2500 24 609.6 2700 24 609.6 2700 24 609.6 2800 24 609.6 2800 24 609.6 3000 26 660.4 3000 26 660.4 1/10 (810) 1/10 (810) 1/10 (810) 1/10 (810) 1/5 (810) 1/5 (810) 1/5 (810 1/5 (810) s Q INDOOR COIL Rows...Fins/in. Face Area (sq ft) 2...17 3.7 2...17 3.7 3...17 3.7 3...17 3.7 3...17 3.7 3...17 3.7 3...17 4.7 3...17 4.7 I J > -03 s INDOOR BLOWER \lominal Cooling Airflow (Cfm) Size in. Size (mm.) Motor HP (RPM) 800 800 1000 1000 1200 1200 1400 1400 l' ------- 10x10 254x254 1/2 (1050) 10x10 254x254 1/2 (1050) 10x10 254x254 1/2 (1050) ' 10x10 254x254 1/2 (1050) 11x10 279.4x254 3/4 (1000) 11x10 279.4x254 3/4 (1000) 11x10 279.4x254 3/4 (1075) 11x10 279.4x254 3/4 (1075) FURNACE SECTION* Burner Orifice No. Natural Gas Qty...Drill Size (Factory Installed) Propane Gas 2...44 2...55 2...38 2...53 2...44 2...55 2...38 2...53 2...38 2...53 3...38 3...53 2...38 2...53 3...38 3...53 HIGH-PRESSURE SWITCH (psig) Cut-out Reset (Auto) 650 +/- 15 420 +/- 25 LOSS -OF -CHARGE / LOW-PRESSURE SWITCH (Liquid Line) (psig) eut-out Reset (auto) 20+/-5 45 +/- 10 RETURN -AIR FILTERSt# Throwaway Size in. (mm) 20x20x1 508x508x25 20x24x1 508x610x25 24x30x1 610x762x25 REVEUTED FOR ©00 OONFLOAM APPROWB Flo042J CoV og l�M�w'th MOLDONO Domooam MMTPLETE RECEDVED COTI Y OF TMKWOLA AGk! 2 0 200 PC RMOT CENTER R c=70 Table 12-8 (portion) Schedule 40 Metallic Pipe Gas Natural Inlet Pressure Less than 2 psi Pressure Drop 0.5 in. w.c. Specific Gravity 0.60 Pipe Size (in ) Nominal: 1/2 13/41 1 1-1/4 1-1/2 2 2-1/2 Actual ID: 0.622 0.824 1.049 1.38 1.61 2.067 2.469 Length (ft) Capacity in Cubic Feet of Gas per Hour 10 172 360 678 1,390 2,090 4,020 6,400 20 118 247 466 957 1,430 2,760 4,400 30 95 199 374 768 1,150 2,220 3,530 40 81 170 320 657 985 1,900 3,020 50 72 151 284 583 873 1,680 2,680 60 65 137 257 528 791 1,520 2,430 70 60 126 237 486 728 1,400 2,230 80 56 117 220 452 677 1,300 2,080 90 52 110 207 424 635 1,220 1,950 100 50 104 195 400 600 1,160 1,840 125 44 92 173 355 532 1,020 1,630 150 40 83 157 322 482 928 1,480 175 37 77 144 296 443 854 1,360 200 34 71 134 275 412 794 1,270 (250-) 30 (63 119 244 366 704 1,120 Table 12-1, Approximate Gas Input for Typical Appliances Appliance Space Heating Units Warm air furnace Single family Multifamily, per unit Hydronic boiler Single family Multifamily, per unit Space -and Water -Heating Hydronic boiler Single family Multifamily, per unit Water -Heating Appliances Water heater, automatic storage 30 to 40 gallon storage 50 gallon Water heater, instantaneous Capacity at 2 gal./min. Capacity at 4 gal./min. Capacity at 6 gal./min. Input Btu/h. 100,000 60,000 100,000 60,000 120,000 75,000 35,000 50,000 142,800 285,000 428,400 Appliance Cooking Appliances Range, freestanding, domestic Built-in oven or broiler unit, domestic Built-in top unit, domestic Other Appliances Refrigerator Clothes dryer, Type 1 domestic Gas fireplace direct vent Gas log Barbeque Gasl', Input Btu/h. R VOC D FOR CODE C OOMPLOQGJ©f ,APPROO MCAD FES ® 4 SOD lots o9. ThCm,2C WIDOW 00VOROOM 65,000 25,000 40,000 3,000 35,000 40,000 80,000 40,000 2,500 RECEIVED CCDTV OF TUKWILA JM 2 2 2 J PERMOT CENTER 07-01-2013 Ci ®f T kw k Jinn Haggerton, Mayor Department of Cornm611dini v Development Jack Pace, Director JOHN WARE 109 WASHINGTON BL. SUITE B ALGONA WA 98001 RIE: 1Pea snit No. Iii[ 113-020 REIT MANAGEMENT 617 INDUSTRY DR TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 08/04/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 08/04/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M l3-020 6300 Southcenter Boulevard, Suite #100 0 Tukwila, Washington 98188 0 Phone 206-431-3670 ° Fav 206-431-3665 January 24, 2013 C°btt�� off ° 71 "oI�wdl�¢ � Jim Haggerton, Mayor Department ®f Community Development Jack Pace, Director John Ware Five Star Mechanical 109 Washington Bl, Suite B Algona, WA 98001 RE: Incomplete Letter #1 Mechanical Permit Application MI3-020 Reit Management — 6117 Industry Dr Dear Mr. Ware, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on January 22, 2013 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Fire Department: Al Metzler at 206 971-8718 if you have questions concerning the attached comments. 1) Please provide the CFM rating of the RTU being installed. The manufacturers specification sheets would be very helpful. Please address the comment above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plans (only the updated/changed sheets), specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431-3670. Sincerely Bill Rambo Permit Technician Enclosures File: M13-020 W: (Permit Centerllncomplete Letters120131M13-020Incomplete Letter #I.docx 6300 Southcenter Boulevard, Suite #100 ° Tukwila, Washington 98188 ° Phone 206-431-3670 Fax 206-431-3665 PERMIT COORD COP" PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-020 DATE: 01/28/12 PROJECT NAME: REIT MANAGEMENT SITE ADDRESS: 617 INDUSTRY DR Original Plan Submittal X Response to Incomplete Letter # I Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Buildin Divi of 06191°17 191 '' 7 9 Public Works Am A/4 \----°1-() Fire Prevention Structural Planning Division CI ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 01/29/13 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/26/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: PER ; CO D CORY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-020 PROJECT NAME: REIT MANAGEMENT SITE ADDRESS: 617 INDUSTRY DR X Original Plan Submittal Response to Incomplete Letter # DATE: 01-22-13 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building Division Public Works I d��►`I ► )i -H 3 Fire Prevention M, Planning Division Structural n Permit Coordinator S DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01-24-13 Complete n Incomplete Not Applicable Comments: Permit Center Use Only 'j }� INCOMPLETE LETTER MAILED: i-\" -A 3 LETTER OF COMPLETENESSIED: Departments determined incomplete: Bldg ❑ Fire' Ping ❑ PW ❑ Staff Initials: �'/� TUES/THURS ROUTING: Please Route n Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02-21-13 Approved n Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 City 0 kwil z 41/ Dep aremetjntt of Coamimaanni y Developanneann 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SU I.) MITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 11— 28— / 3 Plan Cllnech/Pernnnit Number: M13-020 Ak Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner JAN 2 8 20 13 PeWAIT MITER Project Name: ieit Management Project Address: 617 Industry Dr Contact Persona: 1.AA__ QNC__IPlnoune Number: Summall y of Revisionn: /vv., t'`r (4 SD's C - L 27Q Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: 61/4 Entered in Permits Plus on vt7,•-%4S \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: Contractors or Tradespeople Pr ter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name FIVE STAR MECHANICAL UBI No. 601937083 Phone 2538528284 Status Active Address 109 Washington Blvd Ste B License No. FIVESM`010JT Suite/Apt. License Type Construction Contractor City Algona Effective Date 4/30/1999 State WA Expiration Date 5/1/2014 Zip 98001 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 9 Specialty 2 Effective Date Expiration Date Status COMFOMI015LA COMFORT MECHANICAL INC Construction Contractor Heating/Vent/Air -Conditioning And Refrig (Hvac/R) Unused 6/1/1999 4/25/2014 Active COMFOP`064D2 COMFORT PLUS Construction Contractor Air Conditionin g Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/2006 5/24/2008 Expired Business Owner Information Name Role Effective Date Expiration Date WARE, GERALD LAVON Member 01/01/1980 Amount WARE, JOHN EDWARD Member 06/10/2010 9434226 ALLEN, ANGELA RENEE Member 06/10/2010 WARE, BETTY J Member 06/10/2010 FEDERATED SERV/MUT INS CO Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 FEDERATED MUTUAL INS CO 9899743 06/25/2006 Until Cancelled $12,000.00 06/05/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 9 Federated Mutual Ins Co 9434226 04/27/2012 04/27/2013 $1,000,000.00 05/01/2012 8 FEDERATED SERV/MUT INS CO 9434226 04/27/2007 04/27/2012 $2,000,000.00 03/21/2011 7 FEDERATED MUTUAL INS CO 9434226 04/27/2005 04/27/2007 $1,000,000.00 03/27/2006 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httos://fortress.wa. s?ov/lni/bbip/Print.aspx 02/05/2013