Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-098 - YANKEE CANDLE - ALTERATION
YANKEE CANDLE 630 SOUTHCENTER MALL M13-098 City of Oukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 630 SOUTHCENTER MALL TUKW Project Name: YANKEE CANDLE Permit Number: M13-098 Issue Date: 08/21/2013 Permit Expires On: 02/17/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: LAUREN CHASE Address: 16 YANKEE CANDLE WY , S DEERFIELD MA 01373 Email: LAUREN_CHASE@NATIONALPERMITS.COM Contractor: Name: HORIZON RETAIL CONST INC Address: 1516 S GREEN BAY RD , RACINE WI 53406 Contractor License No: HORIZRC072N5 Phone: 410-544-1700 Phone: Expiration Date: 04/15/2015 DESCRIPTION OF WORK: HVAC FOR TENANT IMPROVEMENT Value of Mechanical: $15,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $367.31 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and ami ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with, hether specified herein or not. The granting of this permit does not pr construction or the performance of work. back of this permit. Signature: Print Name: to give authority to violate or cancel the provisions of any other state or local laws regulating am authorized to sign and obtain this mechanical permit and agree to the conditions on the This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. .1..... IRA!, A11 RA1Z_nQA Printcul• ng_91_9n13 PERMIT CONDITIONS Permit No. M13-098 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ***FIRE DEPARTMENT CONDITIONS*** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) doc: IMC -4/10 M13-098 Printed: 08-21-2013 20: An electrical permit from the City iirwila Building Department Permit Center (2 -431-3670) is required for this project. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. a IRA," A!4n M1 2_noR Print rl• nR-21-7n1'i _.t �1r • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Mechanical Permit No. M Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 630 SOUTHCENTER MALL Suite Number: 204 Floor: 2 Tenant Name: YANKEE CANDLE PROPERTY OWNER Name: LAUREN CHASE CIO YANKEE CANDLE Name: WESTFIELD SOUTHCENTER City: S DEERFIELD State: MA Zip: 01373 Address: 633 SOUTHCENTER MALL Email: lauren_chase@nationalpermits.com City: TUKWILLA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: LAUREN CHASE CIO YANKEE CANDLE Address: 16 YANKEE CANDLE WAY City: S DEERFIELD State: MA Zip: 01373 Phone: (410) 544-1700 Fax: (410) 544-1692 Email: lauren_chase@nationalpermits.com New Tenant: m Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the sc f work in delail: Sue P6 -m Use: Residential: New ❑ Replacement ❑ ('-G-om New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 • • Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 5 Floor furnace 1 Suspended/wall/floor mounted heater 1 Appliance vent Repair or addition to headrefrig/cooling system 1 Air handling unit 1 <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 5 Evaporator cooler 1 Ventilation fan connected to single duct 1 Ventilation system Hood and duct 1 Incinerator — domestic 1 Incinerator — comm/industrial • Unit Type Qty Fire damper Diffuser 5 Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment 1 Packaged Roof Top 1 Unit <10,000 cfm Boiler/Compressor (NY 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demo . ated. , ection 15.3.2 International Building Code (current edition). 1 HEREBY C PENALTY 0 BUIL Signature: / / Print Name: `i 9cJl' &' AD AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: f/ft/%i/cL'1Z c 212' u LO G Cmou06-6 1'»/ cc a 4.1z.b( IL/ 13 0(37 5 On/ ¥/J -? H:\Applications\Form-Applications On Line12011 Applications'Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Day Telephone: Datil*i61 24 /do) City State Zip Page 2 of 2 • City of Tukwila ( \ . Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.uov RECEIPT ParcelNo.: 9202470010 Permit Number: M13-098 Address: 630 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 05/30/2013 Applicant: YANKEE CANDLE Issue Date: Receipt No.: R13-02400 Initials: User ID: JEM 1165 Payment Amount: $293.85 Payment Date: 08/21/2013 08:08 AM Balance: $0.00 Payee: HORIZON RETAIL CONSTRUCTION, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 314525 . 293.85 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 293.85 Total: $293.85 Printed• 08-21-2013 r • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M13-098 Address: 630 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 05/30/2013 Applicant: YANKEE CANDLE Issue Date: Receipt No.: R13-01756 Payment Amount: $73.46 Initials: WER Payment Date: 05/30/2013 10:11 AM User ID: 1655 Balance: $293.85 Payee: NATIONAL SERVICES GROUP TRANSACTION LIST: Type Method Descriptio Amount Payment Check 334040 73.46 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 73.46 Total: $73.46 a oe a na Printarl• (153(1_9(113 INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD QIP Retain a copy with permit / 3 PERMIT NO. Projecty)_/1 Ji c (Ad /e. Type gf 1_nspect' n: .p // Address: V Ai (fig Date Called: Special Instructions: Date Wanted , 2i/ 43 "i l p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: f)-efk-T-7,3),-.ite;rt inspec r Date REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule: reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 64 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: P TYppof AJ cAo�: � e c." Address: ( 3 © S. ( AA A----11 Date Called: Special Instructions: Date Wanted: 9 ) 3 , 1 ." 'p my ! j p.m. Requester: Phone No: 2 No: 2-Ci g 9 5- 3 5; ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: Insdector: G Dateq 3 n REINSPECTION FEE REQUIRED. Priir to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 c, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 rY\ 13 -Ore Project: V a +0 e 0 A kI fl tEI Type of Inspection: omq IA --1 ti / () /24.,,,,,„,ti-,01,., 2) Address: CO 3O S 0 Wu A I\ Date Calle IV A i AszicznJ Special Instructions: , j rye ?c/o '-f- t 0.0, p (E�P w►, ,J'Zi,� /-34- I.t ri(ov Date Wanted: `''1 _ t a - 3 '7 -1 -F -,1 A s ( ��--sp---- �. Requester: Phone No: - S 2-6,2-2-6,2-e- �rS % 116 Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: 0 /7o)/9h-;iv -4ap/A,-, 2a 1)›1- , / /7-/ ; 9 v _ 4 ,yhvei () /24.,,,,,„,ti-,01,., 2) 5, -no /&- ,6 -J - 4./aPiciv4 AszicznJ j rye ?c/o '-f- t 0.0, p (E�P w►, ,J'Zi,� /-34- I.t ri(ov '7 -1 -F -,1 A s ( spe : or: Date,; -:I Z' A vvi /? GJ,_/)..) /1 _- /b- INSPECTION Fd REQUIRED. Priclr to next inspection, fee must be aid at 6300 Southcenter Blvd.; Suite 100. Call to schedule reinspection. Mi3-otr INSPECTION RECORD Retain a copywith permit _ INSPECTION.. NO. CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 PERMIT NO. ,4 DIVISION /_ ` (206) 431-3670 \72._ Ge— Project lvAiYxe C(e Typ.e pf ItiMorr / Ad�es3 O S C A.4 p 1 Date Called: Special Instructions:. '•.' . Date Wanted:cam: C r l p.m. Requester: Phone No: Corrections required prior to approval. // COMMENTS:. rec ,.),s , 4A-,6 6 an/ _ -- ) /2) JG It- LAj Ne_ -x Biu 5 `@ re,r c r V) tit Insp(eftor: DateLe", 3 1 --'cis � n REINSPECTION FEEREQU!RED. Prior to next inspection fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule- ins ection. p � p. INSPECT! i N NO. INSPECTION RECORD Retain a copy with permit rI 1�►�11 - —CxiE3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ', (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Y #1'fI'�e C'✓1&iDL Type of Inspection: Izo1( 1-.a J- rV1ee+I Address: Ga 3CD s. 0. 141A/1 Date Called: Special Instructions: • Date Wanted: a.m. Requester: Mil.- IC - Phone No: o. G2 -moi 15 - 5 351 LjApproved per applicable codes. COMMENTS: ipCorrections required prior to approval. 1 7;5 )„, /47,, e Q.. 1ptA.(04_ c.�P iL� ¢ `-f— / Date: e- 304 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at:6300 Southcenter Blvd.. Suite 100. Call to schedule rein"s`pection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 3 F-170 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT k East, Tukwila, Wa. 98188 206-575-4407 Project: %y1hee. C Hite. Type of InGpection: ' , 77at /' Address: i l Suite #: 4_36 SoW/- roe-7/1-ef inn l Contact Person: Special Instructions: Phone No.:. 54 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: 1 ? i " lire., FAc, 9 ,ei rT — f /( Permits: Occupancy Type: m F t e...- Nor f 11/1 # , iP J — i ; F;f a i gu0:3 h! iaern4 t/ thiol /f K Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: f/)14-11 Date: '/,a 7/3 Hrs.: i $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F. P: 113 2009 Washington State Energ Code Compliance Forms for Nonresidential and Multifamil Residential Mechanical Summary MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Info • --to � rri_E r•• Project Address Yankee Candle Date Westfield South For Building Dept. Use Seattle, WA Applicant Name: Yankee Candle Co. - Dave Conway Applicant Address: 16 Yankee Candle Way Applicant Phone: South Deerfield, MA01373 Project Briefly system Ci Description describe mechanical type and features. Indudes Plans Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option • Simple System 0 Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTU -1 HP Carrier 50HCQA06A 60 Econ. 15.0 1 N Heating Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency's Heat Recovery Y/N 1 REi/IEWcD roR RTU -1 Elec. Carrier with RTU 27 ODE OMP` COMPLIANCE: IANCL N ' &.PPROV' D i� , il •. AUG 12 2313 r Fan Equipment Schedule • lacy or (uKWIIa I Equip. ID Equip Type grand Namet Model No.1 CFM EUILDING SP DIVISION Location of Service 'If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP, HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable airvolume(VAV), constant volume (CV), or variable speed (VS). 6 Exception numIAGGEIVED CITY OF TUKWILA AUG 0 6 2013 PERMIT CENTER CORRECTION IsAl3 098 2009 Washington State Energ Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 System Description See Section 1421 for full description p of Simple System qualifications. All Systems: t: No humidification? t: No Reheat? . If Heating/Cooling or Cooling Only: 9 Y t, Constant vol? ■ Split system? • <=t l}00 Btuh? Economizer i de_d� t•; Air cooled? n Packaged sys? • <=135,000 Btuh?, 0 . , "' Cooling Cap <=15 Btuh/ft2? ^' • • Heating Cap. > 0 & <=10 Btuh/ft If Heating Only: • <1000 cfm? • <30% outside air? ■ Heating Cap. <=10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Heating/Cooling or Cooling Only Heating Only Reference Section 1421 alifies Economizer Exception tion 1 Simple System Allowed (section 1420) Use Complex Systems (section 1430) Complex Systems Refer to MECH-COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. II1�•f �1: 1 j fir' Proposed RTU CURBS & WEIGHTS DIMENSIONS - 50HC 04606 (cont.) UNIT STD. UNIT 'WEIGHT CORNER WEIGHT 161 CORNER WEIGHT (8) CORNER WEIGHT (C) CORNER WEIGHT (0) B 42" (1067 mm) 36" (914 mm) Special C.G. C 36" (914 mm) 18" (457 mm) Side condensate drain is used Minimum clearance HEIGHT LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. 4 Y I 50HC-604 458 208 128 58 109 49 101 46 120 54 34 118 1867] 22 1/2 1572] 19 3/4 (502] 5060-405 545 247 156 71 135 61 118 54 136 62 34 5/8 1879] 21 3/4 1552] 20 7)8 [530] 50110-406 550 1249 160 73 136 62 117 53 138 63 34 118 1861] 21 5/8 1549] 20 114 15141 4- STANDARD UN T WEIGHT I5 WITHOUT ELECTRIC HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES REFER TO THE PRODUCT DATA CATALOG. Co4AEA e r 004666 C 00 .l : 00 Fig. 2 - Dimensions 50HC 04-06 0909T REVIEWED FO CODE COM APPROVED JUL 18 2013 City of Tukwila BUILDING DIVISION Fig. 3 - Service Clearance C10224 RECEIVED CITY OF TUKWILA JUL 05 2C3 PERMIT CENTER 008337 LOC DIMENSION CONDITION A 48" (1219 mm) 18" (457 mm) 18" (457 mm) 12" (305 mm) Unit disconnect is mounted on panel No disconnect, convenience outlet option Recommended service clearance Minimum clearance B 42" (1067 mm) 36" (914 mm) Special Surface behind servicer is grounded (e.g.. metal, masonry wall) Surface behind servicer is electrically non-conductive (e.g.. wood. fiberglass) Check for sources of flue products within 10 -ft of unit fresh air intake hood C 36" (914 mm) 18" (457 mm) Side condensate drain is used Minimum clearance D 48" (1219 mm) 42" (1067 mm) 36" (914 mm) Special No flue discharge accessory installed. surface is combustible material Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) Surface behind servicer is electrically non-conductive (e.g.. wood. fiberglass) Check for adjacent units or building fresh air intakes within 10-11 of this unit's flue outlet 20 CORRECTIfON MI ?) 0611) fv2 ;itL¼%c oNiy ® TRAM' . _,�•:•�--�._ Wei ghts - 4,01 0,I Table 139. Maximum unit & comer weights (lbs) and center of gravity dimensions (in) - gas/electric models (IP) Unit Maximum Model Weights(a) (lbs) Corner Weights(b) (lbs) Center of Gravity (in) Tons Model No. Shipping Net A B C D Length Width 5 YSC060ED 689 584 181 144 122 137 40 24 6 YSC072ED 975 843 296 209 158 180 39 21 71 YSC090ED 1016 884 346 198 159 181 36 20 8'/2 YSC102ED 1125 987 325 278 174 210 41 21 10 YSC120ED 1149 1011 344 265 193 209 40 21 (a) Weights are approximate. (b) Corner weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. Table 140. Maximum unit & comer weights (kg) and center of gravity dimensions (mm) - gas/electric models (SI) Unit Maximum Model Weights(a) (kg) Corner Weights(b) (kg) Center of Gravity (mm) Tons Model No. Shipping Net A B C D Length Width 5 WSC060ED 304 256 77 64 44 71 945 609 6 WSC072ED 397 337 114 84 66 73 1003 557 71/2 WSC090ED 439 379 128 89 68 94 933 578 10 WSC120ED 511 448 151 116 78 103 977 547 (a) Weights are approximate. (b) Corner weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. Table 141. Maximum unit & comer weights (lbs) and center of gravity dimensions (in) - gas/electric models (IP) Maximum Model Unit Weights(a) (lbs) Corner Weights(b) (lbs) Center of Gravity (in) Tons Model No. Shipping Net A B C D Length Width 5 WSC060ED 667 562 169 140 96 157 37 24 6 WSC072ED 873 741 251 185 145 160 39 22 71/2 WSC090ED 1 968 836 282 196 150 207 37 23 10 AI WSC120ED 1124 986 332 255 173 226 38 22 (a) Weig is are approximate. (b) Cor er weights are given for information only. All models must be supported continuously by a curb or equivalent frame support. Existing RTU Table 142. Accessory net weights (kg) (a) (SI) Net Weights(b) Accessory(c) T/YSC060ED T/YSC072-120ED Economizer 12 16 Barometric Relief 3 5 Motorized Outside Air RECEIVED Damper 9 14 CITY OF TUKWILA Manual Outside Air Damper 7 12 Roof Curb 28 35 JUL 0 5 2013 Oversized Motor — 4 PERMIT CENTER RT-PRC039-EN Coil Guards 5 9 Hinged Doors 5 5 (a) Weights for options not listed are <3 kg. (b) Net weight should be added to unit weight when ordering factory -installed accessories. (c) Some accessories not available on all units. CORRECTION ��IR# tin py-oori r Yankee Candle - Southcenter Mall - space 204 Mech. Permit Application #M13-098 CURBS & WEIGHTS DIMENSIONS - 50HC 04-06 NOTES: I. OINENSIONS ARE IN INCHES. DIVERSIONS IN [ I ARE IN NIILINETERS. 2. fp CENTER OF GRAVITY 3.00 DIRECTION OF AIR FLOD -1'4 1321 10.1/2 12351 1E7E5 11-5/1 (8431 OUT0I0E 434 21-t/4- 15 97 1 4 11711 1152 i [4011 54600E301C RELIEF' FLO, 51 1r4 ICRIL• 4 11927 A1R RIGHT .ET1UAx 4-518 (118] ELECTRICAL DISCONNECT LOCATION OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 19-112 (4047 45 3/4 [1781] LEFT 06T1044L 6410111 i83L01 OI4C0uECT IiMMOu CONNECTION SIZES A 1 318' [351 DIA FIELD POWER SUPPLY HOLE 6 2' [511 DIA POWER SUPPLY KNOCKOUT C 1 314' [441 DIA GAUGE ACCESS PLUG D 7/8' 122] DIA FIELD CONTROL WIRING HOLE E 3/4'-14 NPT CONDENSATE DRAIN 6 2 112 ' [64] DIA POWER SUPPLY KNOCK -OUT 06T1044L 6410111 i83L01 OI4C0uECT IiMMOu 003180LACSS�804 11111 F'1 . 011 44(300- 8L4 —7 o1011811MEMIMMINIMIIIMO .PJ£ 44918E 14WL1 um FRONT FILTER ACCESS PANEL !TOOL-LESS)COO • ACCCESCES S • PANEL CONDENSER COIL INDOOR COIL ACCESS PANEL o1011811MEMIMMINIMIIIMO .PJ£ THAU-THE-8A E CHART THESE HOLES REQUIRED FOR USE CR6TNP0001401 J THREADED DIRE RE0'D HOLE 18 5/8 (472) CONDUIT SIZE USE SIZES (NAR./ 50HC-406 W. ACC. 1/8' [22.21 X 112' 24,1 118' (22.23 Y 9 3/1' (0011 POKER 1 1/8' 128.41 FOR 'THRU-THE-085E AN' FA TORY OPTION. FITTINGS FOR ONLY X A Y ARE PROVIDED SELECT EITHER 3R' OR 112' FOR 00188. DEPENDING OR DIRE SIZE Fig. 1 - Dimensions 50HC 04-06 19 BACK 2-5/8 �1 [6T1 TYP CURB WIDTH UNIT J K SOH( 404 33 3/8 [847] 18 5/8 (472) 5011C-405 41 3/8 [1051] 14 7/8 (377] 50HC-406 41 3/8 [1051] 14 7/8 [377] C10223 August 2, 2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Lauren Chase Yankee Candle 16 Yankee Candle Wy South Deerfield, MA 01373 RE: Correction Letter #2 Mechanical Permit Application Number M13-098 Yankee Candle — 630 Southcenter Mall Dear Mr. Chase, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431-3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File No. M13-098 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • 1 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo #2 Date: August 2, 2013 Project Name: Yankee Candle Permit # M13-098 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. It has come to our attention that the proposed HVAC unit is not a Heat Pump as required by section 1411.4 of the Washington State Energy Code. It was listed as "yes" in the Mechanical Permit Plans Checklist as being in compliance with this code section. Please revise the plans as necessary showing an appropriate unit that complies with the heat pump requirement. Should there be questions concerning the above information please contact the Building Division at 206-431-3670. June 18, 2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Lauren Chase Yankee Candle 16 Yankee Candle Wy South Deerfield, MA 01373 RE: Correction Letter #1 Mechanical Permit Application Number M13-098 Yankee Candle — 630 Southcenter Mall Dear Mr. Chase, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431-3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made inperson and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, 7510 Bill Rambo Permit Technician File No. M13-098 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • • Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: June 7, 2013 Project Name: Yankee Candle Permit # M13-098 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please provide structural plans and calculations to justify the additional load that the new HVAC rooftop unit will place on the structural members of the building. These plans and calcs will need to be stamped by a structural engineer licensed in the State of Washington. Should there be questions concerning the above information please contact the Building Division at 206-431-3670. PERMIT COORD COPY o PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-098 DATE: 08-06-13 PROJECT NAME: YANK5E CANDLE -SITE ADDRESS: 630 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 2 Revision # After Permit Issued DrTMEN� : `0 BUilding'Divlsion Public Works ❑ Fire Prevention Structural Planning Division n ❑ Permit Coordinator 111 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 08-08-13 Not Applicable Permit. Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions DUE DATE: 09-05-13 Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 PERMIT COORD COPY"' PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-098 DATE: 07/05/13 PROJECT NAME: YANKEE CANDLE SITE ADDRESS: 630 SOUTHCENTER MALL Original Plan Submittal X Response to Correction Letter # 1 Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: l-- (\,Q&L buuaing ulvlslon Public Works Fire Prevention Structural Planning Division Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 07/09/13 Complete k Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/06/13 Approved ❑ Approved with Conditions Not Approved (attach comments) 3' Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: PLAN REHWESSING SLIP ACTIVITY NUMBER: M13-098 DATE: 05-30-13 PROJECT NAME: YANKEE CANDLE SITE ADDRESS: 630 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEP RTME TS: IP d g Division dri1 Public Works ❑ AvA 4'13 Fire Prevention Structural Planning Division 111 ❑ Permit Coordinator 1111 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06-04-13 Not Applicable Comments: Permit Center Use -Only y.. INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route y Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07-02-13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) WJ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg .— Fire 0 Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 A d. • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 08/02/2013 Plan Check/Permit Number: M13-098 Response to Incomplete Letter # Response to Correction Letter # 2 Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Yankee Candle Project Address: 630 Southcenter Mall Contact Person: Wesley Krech Phone Number: (860) 678-1946 x104 Summary of Revision: Please find Revised sheets along with revised Mechanical Permit Plans Summary per Revised HVAC RTU (rooftop unit) equipment specifications, revised in order to comply with section 1411.4 of the Washington State Energy Code. Please note drawings are clouded accordingly, per revised specifications Sheet Number(s): M.1 & M.4 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: �-- Entered in Permits Plus on 1 ( RECEIVED CITY OF TUKWILA AUG 06 2013 PERMIT CENTER H:\Applications\Forms-Applications On Line \2010 Applications\7-2010 - Revision Submittal.doc Revised: May 2011 City of Tukwila •Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwrla.wa.us 1 REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit -Center. Revisions will not be, accepted through the mail, fax, etc. Date: June 24th, 2013 Plan ChecWPermit:Number M13 -U9.8 0 Response to incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision after Permit. is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Yankee Candle. Project Address: 630 Southcenter Mall ED t`� OF TE UKKWILA /JUL 05 2013 PERMIT CENTER Contact Person: Wesley Krech Phone Number: 860.678.1946 x104 Summary of Revision: Per conversation with Dave Larsen on 6/24/13 Regarding mechanical permit application review comment requesting a_rructural calculations for ex. roof structure to support load of new RTU. The exg. RTU 'Trane' #WSC090ED weighs 836 lbs. (see attached spec sheet) The proposed RTU 'Carrier' #50HC-A06 weighs 550 lbs. (see attached spec sheet) The proposed RTU weighs less than the existing RTU. (550 lbs. < 836 lbs.) therefore no additional load is imposed on the existing roof structure. Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit .Ce nter by:: 1 J r kr Entered in Permits Plus on j \applications\fortes-applications on linc\revisionsubmival Created: 8-13-2004 Contractors or Tradespeople Prinfiriendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HORIZON RETAIL CONST INC UBI No. 601483044 Phone 2626386000 Status Active Address 1500 Horizon Drive License No. HORIZRC072N5 Suite/Apt. License Type Construction Contractor City Sturtevant Effective Date 8/25/1993 State WI Expiration Date 4/15/2015 Zip 53177 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date HENDERSEN, JON E Cancel Date 01/01/1980 Amount GUSTIN, ROBERT L 7 01/01/1980 5919211 HENDERSON, JON E 03/29/2014 01/01/1980 JAWORT, DAN Agent 01/01/1980 ZURICH AMERICAN INS CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 HANOVER INS CO 1592447 04/10/2002 Until Cancelled $12,000.00 04/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 ZURICH AMERICAN INS CO 5919211 03/29/2009 03/29/2014 $1,000,000.00 03/18/2013 6 ZURICH AMERICAN INS CO 59192110001 03/29/2006 03/29/2009 $1,000,000.00 03/24/2008 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 08/21/2013 91'-6" - LEASE DIMENSION I'-0" 24'-0" 24'-0" 24'-O" 8'-6" /-� I- PROVIDE UPRIGHT TYPE SPRINKLER QUANTITY ,1 ,1 ,- BTUH ADJACENT TENANT--- BTUH PLUMBING PLAN HEADS IN OPEN CEILING AREAS. M.2 AA iiiiiii iii.i ii/// iiiiiiiiiiii �iiiiii riii iiiii iiiisriiiiii �.riiiiiii iiiii`ilio iiiiiiiiiiii �iiiiiii iiiii iiiiiii iiiiiiiiiiii �iiiiiiii i�%//iiii iiiiiiiiiiii iiiiiiii iiiiiiiiiiii i� iiiiiX71"ilii i iiiiii %iiiiiiiiii iii «��/Jfi" `fr �0�����//d��.�1���`���- 0151r.oG//..J��������Mfff �����`�����Ld�������� ��J�0�1�����//d������GG�Afcf �����i�/�������Z6��.�/d.����.____/�e������������/„��ZZA•-V�//.������1�G���./.e`773 J��s'� //.�����101A���::/.J`��-� _ _ a` /i //iii/ MENS I m m D n U2'/Ul/I3 va 11111 KT 1111 I WAVIII kYMA I Mil I kVA 1 I I I I I I MI,V�101 11104MEIN WA "HIE LY U ILIAT II w Mei zre���ii jff" iiiiiiY i'ZZZ ZA" Affix iiiii of Ar i iiiiii i i iioii i i �is: iiiiii i iiiii i./ i Zor iii r i i i Ar i, i i iiiii .0 hili r i z i i d, iiiii i i iiii�ii iiriii iiiiii i iiiii hili i,/ iiii� i i ii/ii iiiiii i iiiii gr/ iiii�ii ii z ,ii„sii«<,�iii�,�iii,,,ii`�i,i«ii,�ii,�i�«„�»ii,,viii,,,i�ii,,,ii�i,,,r /WE/ ,,»i.i,,,«ii,,, Mechanical Plan RTU -I 5 TONS ADJACENT TENANT EXISTING SPRINKLER SYSTEM SHALL BE MODIFIED AS PER TENANT'S NEW CEILING. CONTRACTOR SHALL RELOCATE HEADS AND MODIFY PIPING AS REQUIRED. ALL SPRINKLER HEADS IN SUSPENDED CEILINGS SHALL BE RECESSED TYPE WITH WHITE COVER PLATES IN SUSPENDED AND GYP. BD. CEILINGS. SCALE: 1/4" = 1'-0" HANGER STRAP SCREWS 0 I' 2' 4' 8' 60" MAX. SCREWS MAY BE OMITTED IF HANGER LOOPS 1 DUCT HANGERS HANGER STRAP MIN. TYP. SCREWS SCREWS MAY BE OMITTED IF HANGER LOOPS M-1 SCALE: NONE SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical ,Electrical Plumbing Gas Piping t: City of Tukwila BUILDING DIVISION IMDesign new INTERIORS LTD FILE COP Permit Na M 1� Pian review approval Is subject to errors and omissions. Apprc al of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field copy and conditions Is ac mowledged: ByDate �� Z®/'3 City Of Tukwila BUILDING DIVISION H.V.A.C. CALCULATION FORM SUMMER SPAGE 10 DEGREES @ 50% R.H. OUTSIDE 86.q DEGREES db / 665 DEGREES vib HEATING SPACE 10 DEGREES, OUTSIDE 21 DEGREES MAX. GFM HEAT LOSS SENSIBLE HEAT GAIN LATENT HEAT GAIN ITEM QUANTITY FACTOR BTUH FACTOR BTUH FACTOR BTUH I. LIGHTING 3.6g10°1ri3413 500 30 DIFFUSER 125'14 LAY -IN METALAIRE / 5000-1 PEOPLE 18 PEOPLE 3.0 KW 500 .4001000..2. 250 3413 4500 1023(1 205 36(1O 3. APPLIANCES 4. OUTSIDE AIR 400 GFM 51.1 20680 13.4 5360 24.6 (1840 5. ROOF 1641 S.F. 4.23 6861 3.12 513(1 NOTES: I) GOLOR SHALL BE BAKED WHITE ENAMEL FINISH. 2.) ALL UNITS TO BE CONSTRUCTED OF ALUMINUM. 3) DIFFUSERS AND REGISTERS SHALL HAVE INTEGRAL BUTTERFLY DAMPERS. 550 6. WALLS --- S.F. --- --- --- --- 80.0/61.0 55.0/54.0 1. GLAZING/DOORS --- S.F. --- --- --- --- a0.0 20 268 550 1 4 60.0 q0.0 208V/3PH 2O8V/3PH 15 TOTALS T -STAT GARRIER/5OHGQAObA2A5-OAOAO 21641 1 -1 31832 13530 TOTAL COOLING = SENSIBLE + LATENT. = 31832 + 13530 = 51362 BTUH GFM SENSIBLE BTUH - 2016 CFM 1.08x11 DEGREES Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 • 1946 F. 860.678.7111 nidesign@nidesign.net © 2013 CONSULTANTS 12035 COLWICK Project Management * Design SAN ANTONIO, TX 78216 SEQUENCE OF OPERATION COOLING CYCLE - OCCUPIED SPACE CONDITION UPON A RISE IN SPADE TEMPERATURE ABOVE THE SETTING OF THE THERMOSTAT, THE ROOF TOP UNIT SHALL BE AGTIVATED, OUTSIDE AIR DAMPER SHALL OPEN, AND FAN SHALL START TO PROVIDE COOLING TO THE SPACE. THE SUPPLY FAN SHALL OPERATE GONTINIOUSLY AND THE COMPRESSOR SHALL GYGLE AS REQUIRED TO MAINTAIN SPADE TEMPERATURE. WHEN THE OUTDOOR AIR TEMPERATURE 15 BELOW 68 PEG. F. THE ROOF TOP UNIT OPERATION SHALL BE CONTROLLED BY THE ECONOMIZER. THE ECONOMIZER SHALL MODULATE THE RETURN AIR AND OUTDOOR AIR DAMPERS TO INTRODUCE UP TO 100 % OUTDOOR AIR TO SATISFY THE MIXED AIR THERMOSTAT, AND THE UNIT EXHAUST FAN SHALL ACTIVATE. COOLING CYCLE - UNOCCUPIED SPACE CONDITION UPON A RISE IN SPADE TEMPERATURE ABOVE THE SETTING OF THE THERMOSTAT, THE ROOF TOP UNIT SHALL BE ACTIVATED TO PROVIDE COOLING TO THE SPADE. HEATING CYCLE - OCCUPIED SPACE CONDITION UPON A DROP IN SPADE TEMPERATURE BELOW THE SETTING OF THE THERMOSTAT, THE ROOF TOP UNIT SHALL BE ACTIVATED, OUTSIDE AIR DAMPER SHALL OPEN, THE HEATER SHALL GYGLE AS REQUIRED TO MAINTAIN SPADE TEMPERATURE. THE SUPPLY FAN SHALL OPERATE CONTINUOUSLY. HEATING CYCLE - UNOCCUPIED SPACE CONDITION UPON A DROP IN SPACE TEMPERATURE BELOW THE SETTING OF THE THERMOSTAT, THE ROOF TOP UNIT SHALL BE ACTIVATED TO PROVIDE HEATING TO THE SPAGE. FIELD VERIFY ALL CONDITIONS DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING CONDITIONS. THE CONTRACTOR SHALL CONTACT THE ARCHITECT, ENGINEER OR TENANT PRIOR TO BIDDING FOR INTERPRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN HI5 5117 ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR TENANT AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTOR'S COST. BIDDING CONTRAGTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL GODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING GODES. THE PLANS AND SPECIFICATIONS NOT WITHSTANDING, THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR TENANT OF ANY APPARENT DISCREPANCIES BETWEEN GOVERNING GODES AND DESIGN INTENT. - YANKEE CANDLE HAS A NATIONAL ACCOUNT WITH CARRIER CORPORATION FOR DIRECT PURCHASE OF THE HVAC CONTROLS AND EQUIPMENT. THE G.G. BID SHALL NOT INCLUDE THE COST OF THE CARRIER EQUIPMENT OR CONTROLS SUPPLIED BY YANKEE CANDLE. UPON BEING SELECTED A5 THE G.G. FOR THIS PROJECT, THE G.G. BECOMES RESPONSIBLE FOR CONTACTING CARRIER'S REPRESENTATIVE, PAUL WITZ (TEL: 800-6q0-1085; FAX 3I5-433-4615) AND PROVIDE HER WITH SITE LOCATION INFORMATION AND THE APPROXIMATE DELIVERY DATES THE EQUIPMENT SHOULD ARRIVE. THE RESPONSIBILTY FOR DELIVERY AND INSTALLATION OF THE HVAC EQUIPMENT WILL TRANSFER TO THE G.G. UPON YANKEE CANDLE AWARDING THE CONTRACT FOR THE PROJECT. REFER TO THE SCHEDULE OF OWNER PROVIDED CARRIER EQUIPMENT ON 51 CET M.4 FOR A DESCRIPTION OF THE ITEMS AND WHO INSTALLS THEM. MECHANICAL GONTRAGTOR SHALL PULL LOW VOLTAGE WIRING AND TERMINATE A5 DETAILED ON THE INSTALLATION DRAWING PROVIDED WITH THE CONTROL EQUIPMENT. MEGHANIGAL CONTRACTOR SHALL INSTALL ALL ACCESSORIES PROVIDED. THE MEGHANIGAL CONTRACTOR SHALL FAX THE STARTUP READINESS FORM TO CARRIER AND SCHEDULE THE VIRTUAL STARTUP. MEGHANIGAL CONTRACTOR SHALL BE ON SITE AT TIME OF VIRTUAL START-UP. GC/MECHANICAL CONTRACTOR WILL PROVIDE IST YEAR WARRANTY RESPONSIBILITY. xx SHEET NOTES REMOVE EXISTING, INSTALL NEW ROOFTOP PACKAGED UNIT INCLUDING ALL ROOF / ROOF FRAMING MODIFICATIONS, DUCTWORK, AUXILIARY STEEL, WIRING, CONDENSATE DRAIN, ETG. SEE DETAILS. 2. PROVIDE AN ENGRAVED PHENOLIC NAME PLATE FOR MEGHANIGAL EQUIPMENT, NAME PLATE SHALL INCLUDE YANKEE CANDLE NAME, SPACE NUMBER, AND EQUIPMENT DESIGNATION IN LETTERING MINIMUM OF 2" IN HEIGHT. 3. INSTALL NEW SPACE SENSOR FOR SALES AREA. MEGHANIGAL CONTRACTOR TO INSTALL MOUNTED AT 54" ABOVE FINISHED FLOOR AT LOCATION SHOWN. REFER TO DRAWING M.4 AND ELEVATIONS ON DRAWING A.3. 4. REMOVE EXISTING, PROVIDE AND INSTALL NEW CEILING MOUNTED EXHAUST FAN / LIGHT FIXTURE ASSEMBLY, INCLUDING ALL DUCTWORK, HANGER ASSEMBLIES, ETG. CONNECT TO EXISTING EXHAUST DUCT. 5. PROVIDE NEW DUCT MOUNTED SMOKE DETECTOR SIMPLEX TYPE *20(48-8636 (OR EQUAL COMPATIBLE WITH FIRE ALARM SYSTEM). DETECTOR SHALL SHUT DOWN UNIT UPON DETECTION OF SMOKE. MEGHANIGAL CONTRACTOR SHALL BE RESPONSIBLE FOR TESTING OF SMOKE DETECTOR. 6. PROVIDE DUCT SMOKE DETECTOR REMOTE TEST AND ALARM INDICATOR SIMPLEX TYPE 4t2018 -g186. 1. PROVIDE AND INSTALL NEW SUPPLY AIR DIFFUSERS AND RETURN AIR GRILLES INCLUDING ALL DUCTWORK, HANGERS, ETG. SEE DETAIL 6/M.2. 8. REMOVE EXISTING SUPPLY AIR DIFFUSERS, RETURN AIR GRILLES ETG., FOR NEW SYSTEM SHOWN. q. PROVIDE NEW SUPPLY AIR DUCTWORK. SEE DETAIL 5/M-2. 10. MECHANICAL CONTRACTOR SHALL PROVIDE DAMPER THAT 15 COMPATIBLE WITH YANKEE CANDLE PROVIDED ACTUATOR. REFER TO SHEET M.4. 11. INSTALL NEW SPACE SENSOR FOR STOCKROOM DAMPER. MEGHANIGAL CONTRACTOR TO INSTALL MOUNTED AT 54" ABOVE FINISHED FLOOR AT LOCATION SHOWN. REFER TO DRAWING M.4. 12. INSTALL NEW ROOM CONTROLLER FOR ROOF TOP UNIT. MEGHANIGAL CONTRACTOR TO INSTALL MOUNTED AT 54" ABOVE FINISHED FLOOR AT LOCATION SHOWN. REFER TO DRAWING M.4. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 12 2013 City of u iia BUILDING ' !SION DEMOLITION NOTE: REMOVE ALL EXISTING EQUIPMENT, DUCTWORK, DIFFUSERS, GRILLES, CONTROLS, SUPPORTS, ETG. NOT BEING REUSED. DO NOT ABANDON IN PLAGE. REFER ALSO TO ARCHITECTURAL DJ DEMOLITION PLAN. DIFFUSER, GRILLE, REGISTER SCHEDULE SYMBOL MAX. GFM NECK SIZE FACE SIZE MAX. FPM MAX. NG LEVEL TYPE CEILING GRID SIZE :.. FRAME TYPE MAKE $ MODEL NOTES: A, ,` 500 I2xI2 24x24 500 30 DIFFUSER 24 x 24 LAY -IN METALAIRE / 5000-1 1,2,3 O 500 12x12 24x24 500 30 DIFFUSER OPEN LAY -IN METALAIRE / 5000-53 1,2,3 0 1200 I8xI8 24x24 500 30 GRILLE 24 x 24 LAY -IN METALAIRE / RH 1,2,3 NOTES: I) GOLOR SHALL BE BAKED WHITE ENAMEL FINISH. 2.) ALL UNITS TO BE CONSTRUCTED OF ALUMINUM. 3) DIFFUSERS AND REGISTERS SHALL HAVE INTEGRAL BUTTERFLY DAMPERS. OUTSIDE AIR CALCULATIONS INT. MECHANICAL CODE - 2012 UNIT NO. ROOM NO. AREA S.F. AREA SERVED PERSONS /1000 5.F. . NO. OF PEOPLE GFM PER PERSON GFM PER S.F. 0.A. REQUIRED 5.A. PROVIDED 0.A. PROVIDED NOTES R11U-I 101 1060 SALES AREA 15 16 20 030 318 1600 320 TOTAL MBTU EAT 102 400 STOCKROOM 3 2 20 0.15 60 400 80 MGA ACTIVATION MAKE MODEL WEIGHT: NOTES: RTU -I 2000 400 1015 550 DHR�IIW 50 615 483 500 45.0 80.0/61.0 55.0/54.0 18 800 17.0 318 2000 400 a0.0 ROOFTOP HEAT PUMP UNIT ELECTRIC HEATING AND COOLING SCHEDULE FAN SECTION COOLING GOIL SECTION HEATING GOIL SECTION ELECTRIC HEATING GOIL SECTION ELECTRICAL SECTION SYMBOL GFM OA RPM FPM TYPE TOTAL 5P TOTAL MEM SEN. MBTU FPM SUCTION TEMP EAT DB/WB LAT DB/WB APD INDOOR TEMP OUTDOOR TEMP FPM TOTAL MBTU EAT LAT App TOTAL MBTU FPM KW EAT LAT VOLTS/PH VOLTS/PH HP MGA ACTIVATION MAKE MODEL WEIGHT: NOTES: RTU -I 2000 400 1015 550 DHR�IIW 50 615 483 500 45.0 80.0/61.0 55.0/54.0 .20 800 17.0 500 2q.4 60.0 a0.0 20 268 550 1 4 60.0 q0.0 208V/3PH 2O8V/3PH 15 56.2 T -STAT GARRIER/5OHGQAObA2A5-OAOAO -12q LBS. 1 -1 NOTES: I) PROVIDE UNIT MOUNTED DISCONNECT SWITCH 2) PROVIDE 1 DAY/24 HOUR PROGRAMMABLE T/STAT 3) PROVIDE I" PLEATED FILTERS 4) PROVIDE 14 ROOF CURB 5) PROVIDE GRAVITY RELIEF DAMPER 6) PROVIDE TEMP. EGONOMIZER WITH BAROMETRIG RELIEF 1) PROVIDE THRU BASE ELECTRICAL FEED. REVISIONS No changes Shal1-----7767-nadQ to the SCOPe of worlt ►ithtaut prior approval of CORRE Tukwila Building Division. LTR# is!07 : E ViSIO Swill require a new plan submittal and may include additional plan review fees - TION RECEIVED CITY OF AUG M 13%098 PERMIT TUKWIL/� 0 � CENTER- DRAWING CHRONOLOGY: index: date: description: 5 6 . 13 ISSUED TO CLIENT FOR FINAL REVIEW 5 .1.13 ISSUED TO LANDLORD FOR FINAL REVIEW 5 . 10 . 13 ISSUED FOR BID 4 PERMIT VI 8 . 2 . 13 REVISED PER RTU SPECIFICATIONS TITLE: Mechanical Plan date: 8 . 2 . 13 drawn by: scale: AS NOTED PROJECT: #644 Westfield South Center Seattle, WA space #: #204 sq. if.: 1,647 job #: 13064 file: 9869 RGISTIEREDHITECT JIMMY POWERS STATE OF WASHINGTON �e. M. 1 1 CANVAS CONNECTION (TYPICAL) REFER TO ROOF CURB DETAIL. ROOFTOP 2" (50 MM) PLUS X X BLOW THRU HVAC UNIT 2X VENT, V LAV CSI- ,.MN. -4 MEN 1 RETURN AI " DUCT CEILING SUPPLY Al DUGT VERIFY IN FIELD IF EXISTING OPENING GAN BE REUSED. PROVIDE OPENING THROUGH ROOF AND ROOF DECK INSULATION NO LARGER THAN REQUIRED TO ALLOW DUETS TO PASS THROUGH. INSTALL ROOFTOP UNIT LEVEL REQUIRED TO ASSURE PROPER DRAINAGE. FLASH AND COUNTER FLASH ROOF PENETRATIONS, ETC. TO ASURE WEATHER TIGHT INSTALLATION. ROOFTOP UNIT M-2 SCALE: NONE v' luWI11D11111uu111111u114111 10. 001 L.1 [10. .01 0110. -1.1241 rel t.1 re new Ow wo 1000/T0ITIT l 00111I11T1Tif0 INSULATION 4 SECTION [111111111100110111111%100111111 111111110111111000111101111111101 SIDE ELEVATION VOLUME DAMPER INSULATION DUCT OUTSIDE END BEARING DAMPER BLADE I/8" (6 MM) CLEARANCE ALL AROUND STIFFEN BLADE A5 REQUIRED DAMPER BLADE HANDLE WITH LOCKING QUADRANT DUCT 1 DETAIL SHOWS SINGLE. BLADE DAMPER. DAMPER INSTALLATION SHALL BE SIMILAR FOR MULTI -BLADE DAMPERS AND ROUND DAMPERS. M-2 SCALE: NONE UNIT TYPE DRAW THRU 2" (50 MM) PLUS X X BLOW THRU I" (25 MM) MINIMUM 2X WHERE X = STATIC PRESSURE IN PAN DRAIN LINE SHALL BE AT LEAST THE SAME SIZE A5 THE NIPPLE ON THE DRAIN PAN PITCH DOWN TOWARD DRAIN GLEAN OUT I" (25 MM) ROOF CONDENSATE TO GONTRETE SPLASH BLOCK, 12"x12" ON NEOPRENE PAD 2 CONDENSATE DRAIN DRAIN PAN M-2 SCALE: NONE WRAPPED INSULATION COVERING RIGID ROUND DUCT (REFER TO NOTE 4) RIGID ROUND SHEET METAL DUET BALANCING DAMPER ADAPTING CURB OR ROOF CURB PROVIDED BY MG EXISTING ROOF CURB (IF APPLICABLE) ROOFTOP UNIT FRAME OPENING WITH STEEL AND %" THROUGH BOLT, WASHERS, LOGKWASHERS AND NUT AT FOUR CORNERS. (A5 REQUIRED) 3 ANCHOR UNIT TO ADAPTING CURB PER MANUFACTURER'S SPECIFICATIONS AND PER LOCAL CODE REQUIREMENTS. ANCHOR ADAPTING CURB TO EXISTING ROOF CURB PER MANUFACTURER'S SPECIFICATIONS AND PER LOCAL GODE REQUIREMENTS. 11 il. nr /\j\ \ ROOF STRUCTURE ROOF CURB CAULK OPENING AROUND SUPPLY AND RETURN DUCTS. ROOF INSULATION M-2 SCALE: NONE INSULATED SUPPLY DUCT BALANCING HANDLE. LOCK INTO POSITION AND MARK PERMANENTLY. NOTES: PROTECTION SADDLE DIFFUSER STARTER COLLAR (REFER TO NOTE 3) I. PROVIDE AT FLEXIBLE DUCT CONNECTION METAL OR "PANDUIT" DRAWBAND ON THE INTERIOR FLEXIBLE DUCT HELIX. SECURE THE INSULATION OVER THE DRAWBAND WITH' AN ADDITIONAL DRAWBAND. 2. PROVIDE BEADING ON ROUND METAL DUCT 12" OR LARGER IN DIAMETER. 3. PROVIDE MINIMUM 4" COLLARS FOR ATTACHMENT OF THE FLEXIBLE DUCT TO ROUND DUCT, DAMPERS AND DIFFUSERS. 4. BAND RIGID ROUND DUCT INSULATION TO DUCT AND PROVIDE TAPE FOR INSULATION OVERLAP. LANDLORDS FIRE PROTECTION NOTES: I. G.C. SHALL CONTRACT W/ A LICENSED FIRE PROTECTION CONTRACTOR APPROVED BY THE LANDLORD, IF REQ, FOR THE MODIFICATIONS TO THE EXISTING SYSTEM A5 REQUIRED TO GOMPLY IN/ APPLICABLE CODES. 2. FIRE PROTECTION CONTRACTOR SHALL COMPLY IN/ ALL NATIONAL, STATE, AND LOCAL FIRE PROTECTION REQUIREMENTS INCLUDING, BUT NOT LIMITED TO, NFPA q6. 3. FIRE PROTECTION PLANS MUST BE ENGINEERED AND WET SEALED BY A LICENSED REGISTERED FIRE PROTECTION ENGINEER IN THE COUNTY, CITY, AND STATE WHERE PROJECT 15 LOCATED A5 REQ. 4. TENANT'S SPRINKLER SYSTEM SHALL BE TESTED IN ACCORDANCE W/ NFPA 13 AND SHALL BE WITNESSED BY THE LOCAL FIRE MARSHAL AND LANDLORD'S REPRESENTATIVE. 5. UPON COMPLETION OF ALL SPRINKLER SYSTEM MODIFICATIONS AND TESTS, G.G. SHALL SUBMIT A WRITTEN CERTIFICATE TO LANDLORD STATING THAT TENANT'S SPRINKLER SYSTEM HAS BEEN INSPECTED AND AI-10VED. 6. G.G. SHALL COORDINATE THE LOCATIONS OF FIRE SPRINKLER HEADS W/ LIGHTING LAYOUT MECHANICAL LAYOUT 4, W/ ANY DUCTWORK OR CEILING OBSTRUCTIONS. SPRINKLER HEADS SHALL BE CENTERED BETWEEN OR ALIGNED W/ LIGHT FIXTURES NOTIFY YANKEE CANDLE OR ARCHITECT OF QUESTIONABLE LOCATIONS FOR VERIFICATION PRIOR TO INSTALLATION. 7. PROVIDE SPRINKLERS ABOVE Q BELOW HARD CEILING AREAS, A5 REQ. BY LOCAL GOVERNING BODY. 6. ANY SPRINKLER LOCATIONS SHOWN ARE FOR DESIGN INTENT ONLY. G.G. SHALL SUBMIT SPRINKLER DRAWINGS TO ALL PARTIES HAVING JURISDICTION AND SHALL OBTAIN ALL APPLICATIONS, PERMITS, AND PAY ALL RELATED FEES q. G.G. TO SUBMIT SPRINKLER SHOP DRAWINGS FOR REVIEW AND APPROVAL TO ARCHITECT PRIOR TO INSTALLATION. ALL INSTALLATION SHALL BE PER APPROVED SHOP DRAWINGS. NInew INTERIORS gyro Design Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 • 1946 F. 860.678.7111 nidesign@nidesign.net © 2013 5 SUPPLY DIFFUSER FLEXIBLE DUCT CONNECTION (REFER TO NOTE I) I X 20 GAUGE GALVANIZED SUPPORT STRAP INSULATED FLEXIBLE DUCT - 5 FOOT MAXIMUM REFER TO NOTE! SQUARE TO ROUND ADAPTOR (IF REQUIRED) CEILING SUPPLY DIFFUSER -WITH LAY -IN FRAME. (SURFACE MOUNT FRAME SIMILAR). * IN AREAS WHERE THERE IS A GYPSUM BOARD CEILING, REMOVE THE DUET MOUNTED LOUVER AND PROVIDE AN ADJUSTABLE LOUVER THAT GAN BE ADJUSTED THROUGH THE AIR DEVICE. M-2 SCALE: NONE CONGEALED SPRINKLER HEAD. ACOUSTICAL TILE CEILING. 6 GOVER PLATE FINISH AS SPECIFIED. CONCEALED SPRINKLER HEAD DETAIL M-2 SCALE: NONE CONSULTANTS Project Management * Design 12035 COLWICK SAN ANTONIO, TX 78216 IIN libc9FY11114,G'' uy III I�il�l4. �II��i 1 II 11„1GXa date 5.6.13 5.1.13 5.10.13 LOGY:: IG' :: 'descI' pPel ) +1l: ISSUED TO CLIENT FOR FINAL REVIEW ISSUED TO LANDLORD FOR FINAL REVIEW ISSUED FOR 511, 4 PERMIT REVIEWED FOR CODE COMPLIANCE APPROVED ,UL1gl013 City of TUKVitia BUILDING DIVISION 1/2" HW INSTANTANEOUS WATER HEATER 8 7 I/ PLUMBING PLAN M.2 SCALE: )/4."=1'-0" PLUMBING CODED NOTES I. PROVIDE NEW POINT OF USE WATER HEATER BELOW THE RESTROOM LAVATORY. SEE DETAIL 1/M2 FOR ADDITIONAL INFORMATION. VERIFY IN FIELD EXACT LOCATION, COORDINATE WITH GENERAL AND ELECTRICAL CONTRACTORS. 2. EXTEND AND CONNECT NEW G.W. LINE TO EXISTING G.W. ® L/L'S MAIN V.I.F.). PROVIDE NEW SHUT OFF VALVE. 3. CONNECT NEW SANITARY LINE INTO LANDLORDS EXISTING SANITARY SERVICE. FIELD VERIFY EXACT LOCATION, SIZE, AND FLOW DIRECTION PRIOR TO BIDDING. INSTALL GLEANOUT AT CONNECTION TO LANDLORDS MAIN AND COORDINATE LOCATION AND TYPE OF COVER REQUIRED TO MATCH FLOOR FINISH WITH YANKEE CANDLE CONSTRUCTION MANAGER. 4. EXTEND NEW VENT TO L'L'S EXISTING VENT MAIN •ABOVE. FIELD VERIFY EXACT VENT MAIN LOCATION AND SIZE PRIOR TO BIDDING: 5. PROVIDE TRAP PRIMER FOR FLOOR DRAIN: 'REFER TO SPECIFICATIONS FOR MODEL AND MANUFACTURER. INSTALL TRAP PRIMER VALVE ASSEMBLY IN WALL AT AN' AGGE55IBLE HEIGHT. PROVIDE AGGE55 PANELS AS REQUIREM EXTEND 1/2" G.W. FROM NEAREST MAIN TO NEW TRAP PRIMER. ; 6. PROVIDE TRAP PRIMER DISTRIBUTION UNIT IN WALL. PROVIDE ACCESS PANEL AND COORDINATE FINAL LOCATION WITH TENANT'S „•k- CONSTRUCTION MANAGER. EXTEND AND CONNECT PIPING TO FLOOR DRAIN. REFER TO DETAIL FOR ADDITIONAL INFORMATION.- • 1/2" GW 1/2" 3 WAY ANGLE STOP VALVE WATER HEATER DETAIL M.2 LE SCALE: NONE PLUMBING LEGEND SYMBOL DESCRIPTION- ----5--- SANITARY/WASTE PIPING, 5, W V VENT, V LAV CSI- COLD WATER PIPING, GW - HW HOT WATER PIPING, HW - - -6-- NATURAL GAS, 6 2" GATE VALVE pd -y1- GHEGK VALVE o fa CLEANOUT • FLOOR DRAIN, F.D. VTR VENT TO ROOF Mechanical Details 5.10.13 drawn a;,,r: clg 2" VENT TO L/L VENT STUB -IN, V.I.F. tV FD 4" SAN. TO L/L SAN. STUB -IN, V.I.F. SANITARY RISER DIAGRAM N.T.S. Salk AS NOTED CONNECT TO L/L'S WATER SERVICE STUB -IN, FIELD VERIFY EXACT LOCATION TRAP PRIMER VALVE IN/ 1/2" G.W. TO FLOOR DRAIN LAV FD WG INSTANTEOUS WATER HEATER, SEE DETAIL WATER RISER DIAGRAM N.T.S. PIZOLIL PLUMBING FIXTURE AND EQUIPMENT SCHEDULE WG - WATER CLOSET - AMERICAN STANDARD, #2168.100 "CADET", FLOOR SET, TANK TYPE, 11-1/4" RIM HEIGHT, BOTTOM OUTLET, WHITE VITREOUS CHINA, ELONGATED BOWL, PRESSURE -ASSISTED SIPHON JET FLUSH AGTION, I.6 GALLON LOW CONSUMPTION TYPE; GLOSE-GOUPLED FLUSHOMETER TANK, WHITE OPEN -FRONT CONTOURED SOLID PLASTIC HEAVY DUTY SEAT LESS COVER WITH SELF-SUSTAINING GHEGK HINGE AND STAINLESS STEEL BOLTS; WHEEL -HANDLE ANGLE STOP VALVE WITH CHROME -PLATED RISER AND CHROME -PLATED ESCUTCHEON. PROVIDE FLUSH LEVER ON ACCESSIBLE SIDE OF WATER CLOSET, OPPOSITE SIDE OF SIDE GRAB BAR. LAV - LAVATORY - AMERICAN STANDARD, #0356.015 "LUCERNE", VITREOUS CHINA 20"x18" WALL HUNG FAUCETS ON 8" CENTERS. MOUNT AT 2q" TO BOTTOM OF EDGE TO MEET "ADA" STANDARD FOR HANDIGAPPED.'FURNISH WITH AMERICAN STANDARD HERITAGE MODEL #6801.372H.002 FAUCET AND POP-UP DRAIN. CHROME I-1/4" x 1-1/2" TAILPIECE WITH "T" CHROME FINISH CAST BRASS TRAP, AND DRAIN TO WALL, ANGEL STOPS, CHROME SUPPLY AND WASTE ESCUTCHEONS. FURNISH WITH MOUNTING HANGERS. INSULATE P -TRAP AND SUPPLY LINES WITH TREUBRO MODEL #1021^1"HANOI-LAV GUARD" INSULATION KIT FOR WHEELCHAIR ACCESS. FD - FLOOR DRAIN WITH FUNNEL, ZURN, CAST IRON POLISHED BRONZE. PROVIDE "PRECISION PLUMBING PRODUCTS" *P2-500 AUTOMATIC TRAP PRIMER WITH ANTI SIPHON PORTS, SERVES 2 FLOOR DRAINS EA. 111-1- INSTANTANEOUS WATER HEA 1 t - IN-SINK-ERATOR MODEL 'W', 0.15 KW, 120V, WITH PLUG * CORD. UNIT SHALL HAVE A FLOW RATE OF 0.5 GPM, SERVICING I LAVATORY,. FCO - FLOOR GLEAN OUT - JAY R SMITH *4043 SERIES, WITH NICKEL BRONZE TOP OF FULL LINE SIZE. INGO - WALL CLEAN OUT - JAY R SMITH #4530 SERIES, CLEAN OUT TEE AND STAINLESS STEEL COVER. WHA - WATER HAMMER ARRESTOR - SIOUX CHIEF 150 SERIES, PDI SIZE A, PIPE SIZE 1/2" TP - TRAP PRIMER - PRECISION PLUMBING PRODUCTS *P2-500, PRECISION PLUMBING PRODUCTS "PRIME RITE" WITH INTEGRAL VACUUM BREAKER. BFP - BACKFLOW PREVENTER - WATTS SERIES 1 61761I, AVAILABLE WITH AN EXTENSIVE COMBINATION OF INLET/OUTLET SIZE TYPES OF THREAD AND END CONNECTIONS INCLUDING RETROFIT COMPRESSION FITTINGS AND HOSE CONNECTIONS. FIXTURES IN THIS SCHEDULE OR THEIR APPROVED EQUIVALENT ARE PROVIDED BY THE PLUMBING CONTRACTOR. SUBMIT SHOP DRAWINGS ON EACH OF THESE ITEMS. VERIFY ROUGH -IN REQUIREMENTS WITH MANUFACTURERS DRAWINGS. INSTALL PER MANUFACTURERS RECOMMENDATIONS. PROVIDE WATER CONSERVING FIXTURES AND APPURTENANCES BY LOCAL AUTHORITIES. REFER TO ARCHITECTURAL ELEVATIONS PLAN FOR MOUNTING HEIGHT OF ALL FIXTURES GENERAL PLUMBING NOTES A. PRIOR TO BID, CONTRACTOR SHALL VISIT THE JOB SITE AND FIELD VERIFY THE EXISTING CONDITIONS. THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING THE EXISTING STUB -INS, TAPS, ETC. FOR PLUMBING AND MECHANICAL SYSTEMS FOR THE TENANT SPACE. THE GONTRAGTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY OF ANY DISCREPANCIES FOUND BETWEEN PLANS AND FIELD CONDITIONS IN ORDER TO PREVENT UNKNOWN ADDITIONAL COSTS TO THE TENANT. B. ALL PIPING SYSTEMS SHALL BE PRESSURE TESTED IN ACCORDANCE WITH STATE, LOCAL CODE AND LANDLORD'S REQUIREMENTS. G. PROVIDE SHUTOFF VALVE(5) AT EACH FIXTURE. D. TENANT SHALL INSTALL AIR CHAMBERS OR SHOCK ABSORBERS IN PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. TENANT SHALL PROVIDE SHUT-OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. E. ALL UNDERGROUND SANITARY PIPING SHALL BE SCHEDULE 40 PVG. F. ALL ABOVE GRADE SANITARY AND VENT PIPING PIPING SHALL BE SERVICE WEIGHT NO -HUB CAST IRON. 6. SANITARY PIPE 3" AND SMALLER SHALL BE SLOPED AT I/4" PER FOOT. SANITARY PIPE 4" AND LARGER SHALL BE SLOPED AT I/8" PER FOOT. CONDENSATE PIPING SHALL BE SLOPED AT A MINIMUM OF 1/4" PER FOOT. H. CAP ALL PIPING OPENINGS DURING CONSTRUCTION UNTIL FINAL CONNECTIONS TO EQUIPMENT AND ACCESSORIES ARE MADE. I. ALL PIPING IN FINISHED AREA SHALL BE RUN CONGEALED. EXPOSED PIPING, WHERE NECESSARY, SHALL BE RUN AS HIGH AS POSSIBLE AND TIGHT TO THE WALLS. DO NOT INSTALL DOMESTIC WATER PIPING IN EXTERIOR WALLS WITHOUT REQUIRED INSULATION. J. SUSPEND ALL HORIZONTAL WATER AND VENT PIPING AS HIGH AS POSSIBLE ABOVE CEILING. K. GORE DRILL ALL SLAB PENETRATIONS. SEAL AROUND ALL WALL, FLOOR AND CEILING PIPE PENETRATIONS WITH AI.1-$ROVED SEALANT MATERIAL AND ENSURE PENETRATIONS REMAIN FIRE RESISTANT AND WATERTIGHT. L. ALL PENETRATIONS THROUGH SLAB SHALL BE SLEEVED, FIRE STOPPED, AND SEALED IN ACCORDANCE WITH THE LANDLORDS STANDARD PROJECT DETAILS. M. ALL EQUIPMENT, INSTALLATIONS AND MATERIALS SHALL COMPLY WITH APPLICABLE LANDLORD CRITERIA, LOCAL AND STATE CODES. N. PROVIDE AND INSTALL WATER HAMMER ARRESTORS PER PD1 REQUIREMENTS. 0. IF EXISTING PLUMBING FIXTURES ARE TO REMAIN, GLEAN AND REPAIR EXISTING FIXTURES TO PROPER WORKING ORDER AND TO LIKE NEW CONDITION. P. LABEL ALL BELOW ELEVATED FLOOR PIPING. 0. CONTRACTOR SHALL VERIFY LOCATION, DIRECTION OF FLOW, AND DEPTH OF UTILITIES AT POINTS OF CONNECTION BEFORE START OF PROJECT. RECEIVED CITY OF TUKWILA MAY 3 0 2013 PERMIT CENTER FIXTURE CONNECTION SCHEDULE P# DESCRIPTION WASTE VENT HW GW . LAV LAVATORY I-1/2" I-1/2" 1/2" 1/2" WC WATER CLOSET 4" 2" - 1/2" FD FLOOR DRAIN 3" 2" - 1/2" #644 (5.-6 #204 Westfield South Center Seattle, WA t'.. 1,647 04 li 13064 Ail"' 9869 nux„�,u REGIS ARO' 111,1,11.111 JIMMY L. POWERS STATE OF WASHINGTON SECTION 15A: HEATING, VENTILATING, AND AIR CONDITIONING: 15A 1 GENERAL INSTRUCTIONS: JS�A 1-1 GENERAL REQUIREMENTS, EACH CONTRACTOR SHALL BE RESPONSIBLE TO BECAME THOROUGHLY FAMILIAR WITH ALL THE CONTENTS OF DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS AS TO THE REQUIREMENTS WHICH AFFECT THIS DIVISION OR SECTION. DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF IEEE SPECIFICATIONS SHALL BE A PART OF THIS SECTION. THE DRAWINSS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR GALLED FOR M ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY GAI L Fn FOR IN BOTH. ANY MATERIAL OR LABOR WHICH 15 NETHER SHOYN ON THE DRAWINGS NOR GALLED FOR 114 THE SPECIFICATIONS, BUT WHICH 15 REQUIRED TO COMPLETE THE WORK, AND MICE (5 INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED A5 PART OF CONTRACT. WHERE THE DRAWINGS OR SPECIFICATIONS GALL FOR ITEMS WHICH EXCEED CODE -5 OR THE LANDLORD'S REQUIREMENTS, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING THE SYSTEM AS DESIGNED AND DESCRIBED ON TIEEC DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, SERVICE5, TOOLS, TRANSPORTATION AND FACILITIES NECESSARY FOR, IMPLIES? AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SYSTEMS SHOWN ON THE DRAWINGS, GALLED FOR IN THE SPECIFICATIONS AND A5 REQUIRED BY JOB CONDITIONS. AA 1-2 rINITION5 FURNISH: THE TERM 'FURNISH' 5 USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM 'INSTALL" 15 USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, GLEANING, AND SIMILAR OPERATIONS.' PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE INTENDED USE." FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITIS( WILL BE FURNISHED BY THE OWNER OR OTHERS. IT 15 TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS OF THIS DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDIS~LTAL TO THE IACRK, INGI.UDINS SERVICES NECESSARY FOR PROPER INSTALLATION AND OPERATION. THE INSTALLATIONSHALL BE INGUIDED UNDER THE GUARANTEE REQUIRED BY THIS DIVISION. ENSINEER: WARE REFERENCED IN THIS DIVISION, "ENGINEER" 15 THE ENGINEER OF RECORD AND THE DESIGN PRO SIGNAL FOR THE WORK UNDER THIS DIVISION, AND 15 A CONSULTANT TO, AND AN AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, A5 DEFINED IN THE GENERAL AND/OR SUPPLEMENTARY CONDITIONS. WHEN USED IN 11415 DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENSINEER, IN ADDITION TO INVOLVEMENT BY, AND OBLIGATIONS TO, THE 'ARCHITECT. MJ THE LOCAL CODE AND/OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. THE THRM 'APPROVED EGUJAL", "EQUIVALENT", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENSINEER AS EQUIVALENT TO 1145 ITEM OR MANUFACTURER SPECIFIED". THE TERM "APPROVED" SHALL MEAN LABELED, USTED, OR 50114, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, GSA), AND ACCEPTABLE TO THE MU OVER THIS PROJECT. j5A 1-3 INSPECTION OF 5ITE. THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK 15 TO BE DONE. FAILURE' TO DO 50 SHALL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO R GUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT FRIGE. ISA 1-4 MATERIAL AND WORKMANSHIP. ALL MATERIAL AND APPARATUS SHALL BE NEW AND IN FIRST GLASS CONDITION. ALL WORKMANSHIP SHALL 65 OF THE FINEST POSSIBLE BY EXETER/MED MECHANICS. ALL INSTALLATIONS SHALL COMPLY WITH APPLICABLE CODES AND LAWS. ANY ABNORMAL 14015E CAUSED BY RATTLING EQUIPMENT, PIPING, DUCTS, AIR DEVICES, AND SQUEAKS IN ROTATING COMPONENTS WILL 140T BE ACCEPTABLE. IN GENERAL, ALL MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE AND QUALITY. L16HT DUTY AND RESIDENTIAL TYPE LS;UIIPMENT SHALL NOT BE ACCEPTED. 15A I-5 COORDINATION, ALL WORK SHALL BE COORDINATED WITH THAT OF OTHER TRADES SO THAT THE INSTALLATION OF THE COMPONENTS OF EACH SYSTEM OCCURS AT THE PROPER TIME, FITS THE AVAILABLE SPADE AND ALLOWS PROPER SERVICE ACCESS TO THOSE ITEMS REWIRING MAINTENANCE. ANY COMPONENTS WHICH ARE INSTALLED WITHOUT REGARD TO THE ABOVE SHALL BE RELOCATED AT 140 ADDIT1OHAL COST TO THE OWER CONTRACTORS SHALL PROVIDE MATERIALS WITH TRIM 101141614 PROPERLY FITS THE TYPE OF CEILING, WALL, OR FLOOR FINISH INSTALLED. MODEL NUMBERS IN SPECIFICATIONS OR SHOWN 014 DRAWINGS ARE NOT INTENDED TO DESIGNATE THE REQUIRED TRIM ISA 1-6 ORDINANCES. LANDLORD CRITERIA AND CODES, INSURE INTO AND COMPLY WTH LANDLORD CRITERIA, LOCALLY ADOPTED CODE OF UBC, IBC, BOLA, NEPA, OSHA AND/OR ALL OTHER APPLICABLE CODES, REGULATIONS AND ORDINANCES. OBTAIN AND PAY FOR ALL PERMITS. CONTRACTOR SHALL BE HED RESPONSIBLE FOR ANY VIOLATION OF THE LAW. CONTRACTOR SHALL MAINTAIN ALL NECESSARY SIGNAL LIGHTS AND GUARDS FOR THE SAFETY OF THE PUBLIC. 15A 1-7 .SHOP DRAWINGS. SUBMIT FOR APPROVAL TWO SETS OF MANUFACTURER'S SHOP DRAWINGS OF ALL MAJOR ITEMS OF EQUIPMENT AND ALL ITEMS REGUIRIN6 COORDINATION BETWEEN .CONTRACTORS TO YANKEE CANDLE'S CONSTRUCTION MANAGER. BEFORE SUBMITTING 5140P DRAWINGS AND MATERIAL LISTS, THE CONTRACTOR SHALL VERITY THAT ALL EQUIPMENT SUBMITTED 15 MUTUALLY COMPATIBLE AND SUITABLE FOR THE INTENDED USE, AND SHALL FIT THE AVAILABLE SPADE AND ALLOW AMPLE ROOM FOR MAINTENANCE. THE CHECKING AND SUBSEQUENT APPROVAL OF SUCH SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN DIMENSIONS, DETAILS, SIZE OF MEMBERS, OR QUANTITIES; OR OMISSIONS OF COMPONENTS OR FITTINGS OR FOR COORDINATING ITEMS WITH ACTUAL BUILDING CONDITIONS. PROVIDE ANY NEEDED WIRING DIAGRAMS. J5A 1-8 ELECTRONIC DRAWING FILES. 114 PREPARATION OF SHOP DRAWINSS,;CONTRAGTOR MAY, AT HIS OPTION, OBTAIN ELECTRONIC DRAWN& FILES IN AUTOCAD OR DXF FORMAT FROM THE ENGINEER FOR A SHIPPING AND HANDLING FEE OF $200 FOR A DRAWING SET UP TO 12 GI ICE TS AND $15 PER SHEET FOR A SET OF MORE THAN 12 SHEETS. CONTRACTOR SHALL FE -SERVICES AND SEND COMPLETED FORM BACK TO . ERVICES ALONG WITH A GHEGK MADE PAYABLE TO PE -SERVICES. CONTRACTOR SHALL INDICATE THE DESIRED SHIPPING METHOD AND DRAWING* FORMAT ON THE ATTACHED FORM. IN ADDITION TO PAYMENT, ARCHITECTS WRITTEN AUTHORIZATION AND ENSINIEER'S RELEASE AGEMENT FORM MUST BE RECEIVED BEFORE ELECTRONIC DRAWING FILES WILL BE SENT. J5A 1-4 GUARANTEE. 6UARANTEE AGAINST DEFECTIVE WORKMANSHIP AND MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL PAYMENT. GUARANTEE SHALL INCLUDE MATERIAL TO BE REPLACED AND ALL LABOR REQUIRED. ISA HO CUTTING AND PATCHING. THE CONTRACTOR SHALL DO ALL GUTTING OF WALLS, FLOORS, CEILINSS, ETC. AS REQUIRED TO INSTALL WORK UNDER THIS SECTION, AND SHALL OBTAIN PERMISSION FROM THE LANDLORD BEFORE DOING ANY GUTTING. STRUCTURAL MEMBERS 514ALL NOT BE DISTURBED WITHOUT PRIOR 'APPROVAL FROM THE ARCHITECT. ALL HOLES SHALL BE GUT AS SMALL AS P055IBLE. GENERAL CONTRACTOR SHALL PATCH NALLS, FLOORS, ETC. A5 REQUIRED BY WORK UNDER THIS SECTION. ALL PATCHING SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION, AND ANY AREAS DISTURBED BY WORK PERFORMED UNDER THIS CONTRACT SHALL BE NEATLY REPAIRED AND REFINISHED TO THE CONDITION OF ADJOINING SURFACES IN A MANNER SATISFACTORY TO THE ARCHITECT AND LANDLORD. 15A 1-11 ROUSH-IN. COORDINATE WITH OTHER CONTRACTORS, WITHOUT DELAY, ALL ROWHING-IN WITH GENERAL GONSTRJJGTION. ALL PIPING, CONDUIT, ROUGH -IN SHALL BE CONGEALED EXCEPT 114 UNFINISHED AREAS AND WHERE OTHERWISE SHOWN. Design new INTERIORS LTD Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 - 1946 F. 860. 678. 7111 nidesign@nidesign.net © 2013 SECTION 15A 2: INSULATION AND SHEET METAL WORKS: J5A 2-1 SURFACE BURNING CHARACTERISTICS ALL MATERIAL EXPOSED IN A CEILING RETURN PLENUM AND OTHER MATERIAL 114 THE AIR STREAM WHICH 15 FURNISHED TO PERFORM WORK REQUIRED UNDER THIS SECTION SHALL HAVE A FLAME SPREAD RATING OF 25 OR LESS AND A SMOKE DEVELOPED RATING OF 50 OR LESS. MATERIAL SHALL BE CLASSIFIED BY UL 123 AS MEETING THE ABOVE REQUIREMENTS AND LABELED AS SUCH. ISA 2-2 DUCT INSULATION. SUPPLY AND RETURN AIR DUCTWORK SHALL BE COVERED WITH I- 1/2" THICK, 3/4 POUND DENSITY DUCT WRAP, GERTAINTEED TYPE IV -4 OR EQUAL OPENER CORNING WITH HEAVY-DUTY FOIL-SGRIERKRAFT FACING, AND WITH ALL JOINTS TAPED WITH 3" WIDE FOIL TAPE. 15A 2-3 SHEETMETAL DUCT. SHEETMETAL DUCT SHALL BE SHOP -FABRICATED, GALVANIZED STEEL, SIZED AND ROUTED AS SHOWN ON DRAWINGS. ALL DUCTS SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH CURRENT SMACNA STANDARDS. DUCTWORK SIZES SHONE,' ARE CLEAR INSIDE DIMENSIONS; METAL SIZE MUST 65 INCREASED TO ALLOW FOR LINER THICKNESS. NO ITEMS, OTHER THAN THOSE REQUIRED FOR THE DUCT INSTALLATION, SHALL BE SUPPORTED FROM THE DUCTWORK INCLUDING BUT NOT LIMITED TO CEILING GRID, CONDUITS, PIPES AND EQUIPMENT. SEAL LONGITUDINAL AND TRANSVERSE JOINTS AND SEAMS AIRTIGHT WITH HEAVY LIQUID SEALANT APPLIED ACCORDING TO MANUFACTURERS INSTRUCTIONS. ALL DUCTS WITH OFFSETS OF 45 DEGREES OR MORE SHALL HAVE AIRFOIL TYPE TURNING VANES OF SAME GAUGE AS DUCTWORK -AND SHALL. BE RIGIDLY FASTENED WITH GUIDE STRIPS. VANES 114 DUCTWORK OVER 30" DEEP SHALL BE INSTALLED IN MULTIPLE SECTIONS WITH VANES NOT OVER 30" LONG AND SHALL BE RIGIDLY FASTENED. ALL DUET CONNECTIONS TO EQUIPMENT SHALL BE WITH NEOPRENE GOATEED GLASS CLOTH CANVAS CONNECTIONS, DURO-DYNE, ELLEN, VENT FABRIC. OR EQUAL. PROVIDE BALANCING DAMPERS NMERE SHOWN ON DRAV'IINGS AND WHEREVER NECESSARY FOR COMPLETE CONTROL OF AIR FLOW. WHERE AGGE55 TO DAMPERS THROUGH A HARD CEILING (5 REQUIRED, COORDINATE ACCESS DOOR LOCATION WITH ARCHITECT, OR AT CONTRACTOR'S OPTION, A YOUNG'S REGULATOR CONGEALED VOLUME DAMPER WITH EXTENSION ROD AND CEILING OPERATOR MAY BE USED. COORDINATE CEILING OPERATOR LOCATION WITH ARCHITECT. SPLITTER DAMPERS SHALL BE CONTROLLED BY LOCKING QUADRANTS; PROVIDE YOUNG'S REGULATOR OR VENTLOK END BEARINGS FOR 114? DAMPER ROD. VOLUME DAMPERS SHALL BE OPPOSED BLADE INTERLOCKING TYPE, FACTORY MADE BY RUSKIN, APC, AIR BALANCE, OR APPROVED EQUAL. OUTSIDE AIR DAMPERS SHALL BE RUSKIN MODEL G12-50, GREENHEGK, AIR BALANCE, OR APPROVED EQUAL. PROVIDE FLEXMASTER MODEL STO OR EQUAL 45 DEGREE RECTANGULAR/ROUND 51DE TAKEOFF FITTING WITH MODEL 51.60 DOUBLE BEARING DAMPER 111114 INSULATION BUILD OUT FOR ALL ROUND DUCTWORK BRANCH TAKEOFFS TO INDIVIDUAL AIR DEVICES. ROUND OR OVAL DUCTS SHALL BE SEMGO, UNITED, WE560 OR EQUAL, GALVANIZED SHEETMETAL, WITH SMOOTH INTERIOR SURFACE. LOW E (DUCT PRESSURE GLASS UP TO AND INCLUDING 2" NG) ROUND DUCT 14" AND UNDER SHALL BE 26 GAUGE, REFERENCE THE LATEST EDITION OF SMACNA HVAC DUCT CONSTRUCTION STANDARDS FOR GAUGE:. REQUIRED FOR ROUND DUCTS GREATER THAN 14' AND WHEN PRESSURES EXCEED 2' W.G. DUCTWORK PASSING THROUSH A FIRE RATED CORRIDOR WITHOUT OPENINGS INTO THAT CORRIDOR SHALL BE A MINIMUM OF 26 GAUGE. LOW PRESSURE (DUCT PRESSURE CLASS UP TO AND INCLUDING 2" WSJ F11111465 24" IN DIAMETER AND LESS SHALL BE PREFABRICATED, SPOTWELDED AND INTERNALLY SEALED. FITTINGS LARGER THAN 24" IN DIAMETER SHALL BE CONTINUOUSLY YELPED: FITTING GAUGE SHALL BE 22 GAUGE FOR 36" FITTINGS AND UNDER 20 GAUGE FOR ALL LARGER SIZES. ALL q0 DEGREE TEES SHALL BE CONICAL TYPE. SEAL LONGITUDINAL AND TRANSVERSE DUCTWORK JOINTS AIRTIGHT WITH HEAVY LIQUID SEALANT APPLIED ACCORDING TO MANUFACTURER'S INSTRUCTIONS. ISA 2-4 FLEXIBLE DUCT, LOW PRESSURE (DUCT PRESSURE GLASS UP TO AND INCLUDING 2" WSJ AND MEDIUM PRESSURE (DUCT PRESSURE GLASS 2.1" TO 6" KG) FLEXIBLE DUCT SHALL BE FLEXMASTER, THERMAFLEX, OR EQUAL TYPE 8 (FIRE RETARDANT POLYETHYLENE) OR TYPE 8M (REINFORCED METALIZED) PROTECTIVE VAPOR BARRIER, U.L.18I CLASS I, ACOUSTICAL INSULATED DUCT, STEEL WIRE HELIX CORE, MECHANICAL LOCK CONSTRUCTION, I-1/2" (R-4.2) FIBERGLASS INSULATION. FLEXIBLE DUCT RUNS SHALL NOT EXCEED 4 FEET IN LENGTH, AND SHALL BE INSTAL 1 Fn AS STRAIGHT AS POSSIBLE WTH NO MORE THAN A 440 DEGREE TOTAL CHANGE 114 DIRECTION. J5A 2-5 AIR DEVICES PROVIDE ALL AIR DEVICES A5 SCHEDULE D ON DRAWINGS, MANUFACTURED BY TITUS. PROVIDE ALL DEVICES WITH A SOFT PLASTIC GASKET TO MAKE AN AIRTIGHT SEAL AGAINST THE MOUNTING SURFACE. CONTRACTOR SHALL COORDINATE FINAL LOCATION, FRAME, AND MOUNTING TYPE OF ALL AIR DEVICES WITH ARCHITECTURAL REFLECTED CEILING PLANS. SECTION 15 3: HVAC EQUIPMENT: ISA 3-2 FINAL HVAC TESTING AND ADJUSTMENTS. FINAL SYSTEM TESTING, BALANCING AND ADJUSTMENTS SHALL BE PERFORMED BY A CONTRACTOR CERTIFIED BY THE NATIONAL ENVIRONMENTAL BALANCING BURE=AU (NEBB) OR ASSOCIATED AIR BALANCE COUNCIL (AABC). TESTS SHALL NOT BE PERFORMED BY INSTALLING COMPANY. TEST AND BALANCE CONTRACTOR SHALL PERFORM( TEST READINGS 014 ALL FANS, UNITS, COILS, ETC,. AND ADJUST ES;IUIPMENT. TO DELIVER SPECIFIED AMOUNTS OF AIR. A CERTIFIED AIR BALANCE REPORT SHALL BE SUBMITTED 014 CERTIFIED "NEB" OR "AABG" FORM. REPORTS SUBMITTED ON NON CERTIFIED OR CUSTOMIZED REPORTS HILL NOT BE ACCEPTED. THE REPORT SHALL INCLUDE AT A MINIMUM ALL AIR SUPPLY, RETURN AND EXHAUST QUANTITIES; FAN AND UNIT TEST READIN55 ENTERING EQUIPMENT AND LEAVING EQUIPMENT AIR TEMPERATURES; TIE REPORT SHALL INCLUDE ALL NAMEPLATE DATA OF INSTALLED EQUIPMENT. THE AIR BALANCE CONTRACTOR SHOULD EXPECT TO FOLLOW UP AND PERFORM AIR BALANCE REQUIREMENTS FOR ALL OUT OF DE51614 AND NON FUNCTIONAL SEASONAL SYSTEMS. (2) COPIES OF THE FINAL COMPILATION OF DATA SHALL BE SUBMITTED TO THE ARCHITECT FOR EVALUATION AND APPROVAL BEFORE FINAL INSPECTION OF THE PROJECT. REPORT SHALL BE BOUND AND INCLUDE THE STORE NAME, MALL NAME, SPADE NUMBER, AND CITY WHERE TESTING AND BALANCING HAS BEEN PERFORMED. AIR BALANCING SHALL BE PERFORMED WITH A qS% ACCURATE AIR VELOCITY METER. AIR FLOWS SHALL BE BALANCED TO WITHIN PLUS/MINUS 10% OF DE51614 REQUIREMENTS. THE AIR BALANCE REPORT SHOULD INCLUDE DATA AND COURSE OF ACTION REQUIRED IF SYSTEM GAN NOT BE BALANCED WITHIN I0% OF DESIGN REQUIREMENTS. THE OWNER MUST RECEIVE THE AIR BALANCE REPORT NO LATER THAN (5 DAYS FROM THE STORE TURNOVER DATE. ALL BEARINGS SHALL BE LINED UP. BEARINGS THAT HAVE DIRT OR FOREIGN MATERIAL IN THEM SHALL EE REPLACED WITH NEIN 'BEARING5,INITHOUT ADDITIONAL DOST TO THE OWNER ALL THERMOSTATS AND CONTROL DEVICES SHALL BE ADJUSTED TO OPERATE AS INTENDED, COORDINATE WITH YANKEE CANDLE'S PRO.EGT MANAGER. COORDINATE START UP WITH ALG AND YGG PROJECT MANAGER. ADJUST BURNERS, PUMPS, FANS, ETC. FOR PROPER AND EFFICIENT OPERATION. CERTIFY TO Y.G.G. PROJECT ARCHITECT THAT ALL ADJUSTMENTS HAVE BEEN MADE AND THAT SYSTEM 15 OPERATING SATISFACTORILY. ADJUST ALL AIR DEVICES TO SUPPLY TIE AMOUNT OF AIR SHOWN ON THE DRAWINGS. FURTHER. ADJUSTMENTS SHALL BE MADE TO OBTAIN UNIFORM TEMPERATURE 114 ALL SPADES. CALIBRATE, SET, AND ADJUST ALL AUTOMATIC TEMPERATURE CONTROLS. CHECK FIROPER 5E)ENCINI& OF ALL INTERLOCK SYSTEMS, AND OPERATION OF ALL SAFETY CONTROLS. ALL ADJUSTMENTS SHALL BE BY GENERAL CONTRACTOR AT 140 ADDITIONAL DOST TO YANKEE CANDLE CORPORATION. YANKEE CANDLE HAS A NATIONAL ACCOUNT WITH CARRIER CORPORATION FOR DIRECT PURCHASE OF THE HVAC CONTROLS AND EQUIPMENT. THE G.G. BID SHALL NOT INCLUDE THE COST OF THE CARRIER EQUIPMENT OR CONTROLS SUPPLIED Sy YANKEE CANDLE. UPON BEING SELECTED A5 THE G.G. FOR THIS PROJECT, THE G.G. BECOMES RESPONSIBLE FOR CONTACTING CARRIER'S REPRESENTATIVE, PAUL WITZ (TEL: 800-6qO-1085; FAX 315-433-4615) AND PROVIDE HER WITH SITE LOCATION INFORMATION AND THE APPROXIMATE DELIVERY DATES THE EQUIPMENT SHOULD ARRIVE. THE RESPONSIBILTY FOR DELIVERY AND INSTALLATION OF THE HVAG EQUIPMENT WILL TRANSFER TO THE G.G. UPON YANKEE CANDLE AWARDING THE CONTRACT FOR THE PROJECT. REFER TO THE SCHEDULE OF OWNER PROVIDED CARRIER EQUIPMENT ON SHEET M-401 FOR A DESCRIPTION OF THE ITEMS AND WHO INSTALLS THEM. MEGHANIGAL CONTRACTOR SHALL PULL LOW VOLTAGE WIRING AND TERMINATE AS DETAILED ON THE INSTALLATION DRAWING PROVIDED WITH THE CONTROL EQUIPMENT. MEGHANIGAL CONTRACTOR SHALL INSTALL ALL ACCESSORIES PROVIDED. THE MEGHANIGAL CONTRACTOR' SHALL FAX THE STARTUP READINESS FORM TO CARRIER AND SCHEDULE THE VIRTUAL STARTUP. MECHANICAL CONTRACTOR SHALL BE ON SITE AT TIME OF VIRTUAL START-UP. GG/MEGHANIGAL CONTRACTOR WILL PROVIDE IST YEAR WARRANTY RESPONSIBILITY. CONSULTANTS 12035 COLWICK Project Management * Design SAN ANTONIO, TX 78216 SECTION 15C: AUTOMATIC SPRINKLER SYSTEM: 156 I-1 INSPECTION OF 51TE. THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY IN%ORMED AS TO THE CONDITIONS UNDER WHICH THE WORK 15 TO BE DONE. FAILURE TO DO 50 WILL NOT BE CONSIDERED SUFFICIENT .!<J5TIFIGATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. 1501-2 SCOPE. ALL SPRINKLER WORK SHALL 5E PERFORMED BY A LANDLORD APPROVED LICENSED SPRINKLER CONTRACTOR. FIRE PROTECTION SPRINKLER CONTRACTOR (FP56) SHALL PROVIDE A COMPLETE AND FUNCTIONING SPRINKLER SYSTEM WITH VALVES, PIPING AND HEADS, THROUGHOUT THE TENANT SPADE. FPSG SHALL VERIFY REQUIREMENTS WITH LOCAL CODE OFFICIALS PRIOR TO BID. FPSG SHALL VERIFY AND COORDINATE ALL WORK WITH THE LANDLORD SPRINKLER CONTRACTOR ALL SYSTEMS SHALL:' BE CHARGED AND OPERATIONAL WHEN THE FPSG 15 NOT ON THE PREMISES OR FPSG SHALL POST A FIRE WATCH. ALL WORK SHALL BE SCHEDULED WITH THE LANDLORD'S FIELD REPRESENTATIVE. SYSTEM SHALL BE 114 ACCORDANCE WITH THE LATEST EDITION OF STANDARD *13 OF THE NATIONAL FIRE PROTECTION ASSOCIATION (NEPA), AND MUST BE ACCEPTABLE TO THE INSURANCE INTEREST HAVING JURISDICTION, THE FIRE MARSHAL, AND LOCAL, STATE, AND NATIONAL CODES HAVING JURISDICTION. WORK SHALL INCLUDE, BUT SHALL. NOT NECESSARILY BE LIMITED TO THE FOLLOWING: I. EXTENSION OF EXI5TINS OVERHEAD WET: PIPE SPRINKLER SYSTEM FOR TENANT SPADE. 156 1-3 INSTALLATION REQUIREMENTS. FIRE PROTECTION SYSTEM COMPONENTS SHALL BE MANUFACTURED BY GRINNELL, RELIABLE, CENTRAL, VIKING, POTTER-ROEMER, OR APPROVED EQUAL OR AS SPECIFIED HEREIN. PIPING IN AREAS HAVING GEILIN65, OTHER THAN THE UNDERSIDE OF THE ROOF DECK, SHALL BE CONGEALED. PIPING IN AREA5 WITHOUT GEILIN65 MAY BE EXPOSED BUT KEPT AT A MINIMUM DISTANCE FROM THE DECK. ALL PIPING SHALL BE GLEAN AND FREE OP RUST. SPRINKLER HEADS IN AREAS WITH WHITE FINISHED HARD CEILINGS (GYPBOARD, ETGJ OR WHITE F1141514ED ACOUSTICAL CEILINGS (LAY -IN, ETC.) SHALL BE CONGEALED TYPE 111T14 1114175 DROP -AWAY COVERPLATE. SPRINKLER HEADS IN WOODEN SOFFITS SHALL BE CONGEALED TYPE P41TH BLACK DROP -AWAY COVER:LATE. SPRINKLER HEADS IN AREAS OF EXPOSED PIPING MAY BE PENDANT OR UPRIGHT TYPES WITH ROUGH BRASS FINISH. SPRINKLER HEADS IN HARD CEILINGS, UNLESS FUNCTIONALLY IMPOSSIBLE, SHALL BE CENTERED WITH AND BETWEEN ROWS OF LIGHT FIXTURES. SPRINKLER HEADS IN LAY -IN CEILINGS, UNLESS FUNCTIONALLY IMPOSSIBLE, SHALL BE CENTERED IN THE CEILING TILE. SPRINKLER PIPING 2-1/2" AND LARGER MAY BE SCHEDULE 10 BLACK STEEL. SPRINKLER PIPING I- I/4" THROUGH 2" MAY BE ALLIED 'XL' OR APPROVED EQUAL. I" PIPING SHALL BE SCHEDULE 40 BLACK STEEL, ALLIED TUBE OR EQUAL. PIPES SHALL HAVE WELDED, SGRFJ^ED, OR MECHANICALLY JOINED FITTINGS. PROVIDE AND INSTALL BACKFLOW PREVENTION EQUIPMENT IF REQUIRED BY LOCAL CODES. PROVIDE AND INSTALL FULL FLOW FIRE METER OR DETECTOR GHEGK METER IF REQUIRED. P5516N5 REQUIRING CUTTING OF STRUCTURAL MEMBERS FOR PASSAGE OF SPRINKLER PIPES OR HANGERS SHALL 55 AVOIDED. WHEN DESIGN REQUIRES GUTTING, DUE TO ECONOMY, APPEARANCE OR SIMILAR ASPECTS, IT SHALL BE HELD TO AN ABSOLUTE MINIMUM AND DONE ONLY WITH THE ARCHITECT'S WRITTEN APPROVAL. 600r DINATE ALL SCHEDULING AND WORK WITH OTHER TRADES 50 AS TO PREVENT CONFLICTS, AND TO ENSURE ORDERLY PROGRESS OF THE WORK, WITH A MINIMUM OF DELAYS. WHERE SPRINKLER PIPING 16 INSTALLED WITHOUT COORDINATING WITH OTHER TRADES AND CONFLICTS OGGUR, SPRINKLER PIPING SHALL BE RELOCATED A5 REQUIRED AT 140 ADDITIONAL DOST TO THE OWNER TO RESOLVE THE CONFLICTS. WHERE PIPING PASSES THROUGH WALLS, FLOORS, CEILINGS, OR OTHER BUILDING CONSTRUCTION, SLEEVES SHALL BE USED. WHERE EXPOSED PIENS PASSES THROUGH FINISHED WORK, CHROME PLATED ESCUTCHEONS SHALL BE INSTALLED TO FIT SNU SLY AROUND THE PIPING. WHERE PIPING PASSES THROUGH UNFINISHED WORK SUITABLE PLATES SHALL BE PROVIDED AT EAGH HOLE TO ASSURE EFFECTIVENESS OF CONSTRUCTION AS A FIRE STOP. SEAL ALL PENETRATIONS THRU EXTERIOR ELEMENTS WATERTIGHT AND PEATHERTIGHT. PENETRATIONS THRU FIRE RATED ELEMENTS SHALL BE CAULKED WITH 3M CP 25 FIRE BARRIER CAULK (THICKNESS AS REQUIRED AND RECOMMENDED BY MANUFACTURER) TO MAINTAIN FIRE RESISTANCE RATING OF FIRE -RATED ASSEMBLIES. PROVIDE ALL ITEMS OF SPRINKLER SYSTEMS MODIFICATION REQUIRED BECAUSE OF BUILDING REMODELING, AS NOTED ON THE DRAWINGS, OR NECESSARY FOR PROPER OPERATION. HVAC Responsibility Schedule A 5 w z LI TENANT INSTALLED DO C Q a IC, INSTALLED Q I z 0 W COMMENTS PACKAGED ROOFTOP UNIT • • REFER TO M.4 DUCT HEATER NOT APPLICABLE ROOF CURB •_ • • IF NOT EXISTING ROOFING • • • IF NOT EXISTING ROOF GANT STRIP • • • IF NOT EXISTING ROOF CURB LEVELING • • • A5; REQUIRED DIFFUSERS AND GRILLES • • • REFER TO M.4 WALL FIRE DAMPERS • • • IF NOT EXISTING, AS REQUIRED COMB. FIRE/SMOKE DAMPERS 0 • • IF NOT EXISTING, A5 REQUIRED LOW PRESSURE DUCTWORK • • REFRIGERANT PIPING • • • IF NOT EXISTING CONDENSATE PIPING • • • IF NOT EXISTING DUCT SUPPORTS • • SEISMIC BRACING • • A5 REQUIRED CARRIER TEMP CONTROL SYSTEM • • REFER TO M.4 EQUIPMENT AND CONTROL START-UP • • REFER TO M.4 MOTOR OPERATED DAMPER • • WIRED BY ELECTRICAL CONTRACTOR SMOKE DETECTORS • • _ ZONE DAMPERS _ • • REFER TO M.4 ZONE DAMPER ACTUATOR • • REFER TO M.4 TOILET EXHAUST FANS • • WIRED BY ELECTRICAL CONTRACTOR TOILET EXHAUST DUCTWORK • • AS REQUIRED TOILET EXHAUST ROOF CURB • • AS REQUIRED AIR BALANCE REPORT • AS -BUILT DRAWINGS • IST YR LABOR WARRANTY CARRIER EQUIP. • IST YR PARTS WARRANTY CARRIER EQUIP. • 1111(10X:', 5.6.13 5.7.13 5.10.13 ISSUED TO CLIENT FOR FINAL REVIEW ISSUED TO LANDLORD FOR FINAL REVIEW ISSUED FOR BID 4 PERMIT MECHANICAL LEGEND: AFF AH GD GFM GU DIA DWG EA EER EFF. E.S.P. FD HP KW LD MBH OA OP. WT. PRESS. RO RTU SA 56 SR TYP UH ABOVE FINISHED FLOOR AIR HANDLER CEILING DIFFUSER CUBIC Fl=t I PER MINUTE CONDENSING UNIT DIAMETER DRAWING EXHAUST AIR ENERGY EFFICIENCY RATIO EXHAUST FAN EFFIGIENGY EXTERNAL STATIC PRESSURE FIRE DAMPER GRILLE HORSE POWER KILOWATTS LINEAR DIFFUSER THOUSAND BTU/HOUR OUTSIDE AIR OPERABLE WEIGHT PRESSURE RETURN AIR ROOF OPENING ROOFTOP UNIT SUPPLY AIR SUPPLY GRILLE SUPPLY REGISTER TYPICAL UNIT HEATER 1 -�-- O s .l7.4/74744 MECHANICAL GENERAL NOTES: I. PRIOR TO SUBMITTING BID, THE CONTRACTOR AND HIS SUBCONTRACTORS SHALL VISIT THE JOB SITE AND FULLY ACQUAINT ONESELF WITH THE EXISTING CONDITIONS OF THE PROJECT. THE CONTRACTORS AND SUBCONTRACTORS SHALL BE RESPONSIBLE FOR REVIEW OF THE GENERAL NOTES, SPECIFICATIONS, AND ALL OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WEIGH MAY NOT BE SPECIFICALLY GALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY YGG CONSTRUCTION MANAGER OF ANY CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. DRAWINGS FOR HVAG WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALL NOT BE SCALED FOR EXACT MEASUREMENT. FIELD MEASURE FOR FINAL DUCTWORK PRIOR TO FABRICATION AND MAKE NECESSARY ADJUSTMENTS TO FIT THE DUCTWORK WITHIN THE AVAILABLE SPACE. FIELD VERIFY FINAL LOCATIONS FOR EQUIPMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. 3. INSPECT ALL EXISTING EQUIPMENT INDICATING TO REMAIN, AND REPORT ANY DAMAGE OR REPAIRS REQUIRED. THOROUGHLY WIPE DOWN WITH CLEAN RAGS OR VACUUM GLEAN SAID EQUIPMENT, INCLUDING BUT NOT LIMITED TO ALL AIR OUTLETS AND INLETS. 4. EXERCISE CAUTION IN PERFORMING' THE WORK 50 AS NOT TO DAMAGE ANY EXISTING CONDITIONS OR SYSTEMS THAT ARE TO REMAIN IN PLACE. CORRECT ANY DAMAGE CREATED BY THIS WORK TO THE SATISFACTION OF THE ARGHITEGT WITHOUT ADDITIONAL COST TO THE OWNER. 5. MAXIMUM LENGTH OF FLEXIBLE DUCT TO DIFFUSERS, REGISTER, OR GRILLE SHALL BE 5'-0". 6. DUCTWORK SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. 1. EXISTING ITEMS SHOWN ON PLAN ARE PROVIDED FOR COORDINATION PURPOSES. THE LOCATION AND ELEVATION OF THESE ITEMS SHALL BE VERIFIED PRIOR TO SUBMITTING BID. NOTIFY YGG CONSTRUCTION MANAGER AND NI DESIGN OF ANY CONFLICTS OR DISCREPANCIES. 8. THERMOSTATS AND TEMPERATURE SENSORS SHALL BE LOCATED GENERALLY A5 SHOWN, HOWEVER THEIR EXACT LOCATION AND COLOR SHALL BE COORDINATED WITH Y.G.G. CONSTRUCTION MANAGER. MOUNT THERMOSTATS AT 54" ABOVE FINISHED FLOOR. q. GENERAL CONTRACTOR SHALL PROVIDE AGGESS PANELS IN GWB CEILINGS, AND WALK PLATFORMS ABOVE, AS REQUIRED FOR SERVICING ALL HVAG EQUIPMENT, INCLUDING BALANCING DAMPERS, FIRE DAMPERS, AND SMOKE CONTROL DAMPERS. AGGESS PANELS AND WALKS SHALL BE SHOWN ON ARCHITECTURAL PLANS AND REFERENCED ON MECHANICAL PLANS. GENERAL CONTRACTOR MUST ENSURE THAT THE CEILING STRUCTURE OR THE WORK OF ANY OTHER TRADE DOES NOT BLOCK AGGESS TO DAMPERS AND EQUIPMENT ABOVE THE CEILING 50 THAT PERIODIC MAINTENANCE AND TESTING GAN BE PERFORMED. Mechanical Notes 91' 1111a 5 . 10. 13 CfraWby" clg II2r': AS NOTED SUPPLY DIFFUSER RETURN OR EXHAUST GRILLE TEMPERATURE SENSOR RTU CONTROLLER SMOKE DETECTOR BALANCING DAMPER FIRE DAMPER AIR FLOW INDICATES CODED NOTE POINT OF CONNECTION EXISTING DUCTWORK TO REMAIN EXISTING DUCTWORK TO BE REMOVED NEW DUCTWORK (INS. DIM.'S SHOWN) REVIEWED FOR CODE COMPLIANCE APPROVED JUL '18,2013 City of Tukwila BUILDING DIVISION 10. MECHANICAL CONTRACTOR SHALL FURNISH THE LANDLORDS ON-SITE REPRESENTATIVE WITH TWO COPIES OF A CERTIFIED AIR BALANCING REPORT PREPARED BY AN INDEPENDENT AABG OR NEBB CERTIFIED AIR BALANCING CONTRACTOR. MEGHANIGAL CONTRACTOR SHALL COMPLETE THE START-UP AND AIR BALANGE REQUEST, ENSURE THAT EQUIPMENT 15 READY TO OPERATE AND CONTACT DIRECTOR OF OPERATIONS WHEN READY FOR START-UP AND AIR BALANCE OF THE HVAC SYSTEM. MEGHANIGAL CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL TRADES, LANDLORD REQUIREMENTS, CEILING HEIGHTS AND EXISTING STRUCTURAL CONDITIONS PRIOR TO FABRICATION OF ANY DUCTWORK OR ORDERING OF ANY EQUIPMENT. 12. MECHANICAL CONTRACTOR TO PROVIDE TENANT WITH AS -BUILT DRAWINGS AND SHOP DRAWINGS FOR ALL EQUIPMENT PROVIDED. 13. VERIFY THE EXACT MOUNTING FRAME REQUIRED FOR EACH AIR DEVICE. 14. DEMOLITION - REMOVE EXISTING ROOFTOP UNIT. COORDINATE SELECTIVE DEMOLITION OF DUCTWORK AND DIFFUSERS WITH ARCHITECTURAL DEMOLITION PLAN. 15. PROVIDE CEILING RADIATION DAMPERS FOR ALL DIFFUSERS AND GRILLES PER IMG 607.5, 601.6.2; IBC 716.6.2. 16. MEGHANIGAL CONTRACTOR SHALL OBTAIN OBTAIN A COPY OF THE MALL GRITERA PRIOR TO BIDDING THIS PROJECT. ALL THE REQUIREMENTS IN THE MALL CRITERIA SHALL BE INCORPORATED INTO THE SCOPE OF WORK. VERIFY ALL REQUIREMENTS PRIOR TO BID. MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR DEMOLITION OF EXISTING DUCTWORK, ROOFTOP UNIT AND ANY OTHER ASSOCIATED COMPONENTS. UPON COMPLETION OF DEMOLITION, SPACE SHALL BE SUITABLE FOR INSTALLATION OF NEW HVAG SYSTEM. FIELD CONFIRM EXISTING CONDITIONS FOR IMPLEMENTATION OF NEW SYSTEM. 11. X 13-078 #644 #204 Westfield South Center Seattle, WA 1,647 j11::::!!1::::! 13064 I I ibl RECEIVED CITY OF TUWCWILA MAY302013 PERMIT CENTER REGI ARC1 JIMMY L. PO ERS STATE OF WASHINGTON ;ill „00 111 111111 111.111,11, EMS CABLE LEGEND TAG EMS # CABLE DESCRIPTION 1 EMS -1 22/2 COMMUNICATION 2 EMS -2 22/8 RTU CONTROL 3 EMS -3 22/2 SMOKE ALARM 4 EMS -4 22/2 PRIMARY AIR TEMP 5 EMS -5 22/2 FAN STATUS CSW 6 EMS -6 22/2 SUPPLY AIR TEMP 7 EMS -7 22/2 OUTDOOR AIR TEMP 8 EMS -8 22/8 SALES SPACE SENSOR 9 EMS -9 22/2 ZONE DAMPER 10 EMS -10 22/2 STORAGE SPACE SENSOR 16 EMS -16 22/2 POWER EXH (WHEN REQ'D) ROOF DECK clue smo\tt b4C/kor ov wor Uai TA& OWNER -FURNISHED CARRIER EQUIPMENT QTY. DESCRIPTION PART# INSTALL BY 1 EMS PANEL ALC EMSP ELECTRICAL 1 HVAC UNIT CONTROLLER ALC RC642D MECHANICAL 1 SALES SPACE SENSOR ALC RS -BASE MECHANICAL 1 STORAGE SPACE SENSOR BAPI ALC/10k-2-R MECHANICAL 1 DUCT TEMP SENSOR BAPI ALC/10k-2-D-8 MECHANICAL 1 OUTSIDE AIR SENSOR BAPI ALC/10K-2-0 MECHANICAL 1 CURRENT SWITCH VERIS H900 MECHANICAL 1 DAMPER ACTUATOR BELIMO LF24-US MECHANICAL 2 ACTIVE NETWORK TERMINATOR ALC BT485 MECHANICAL 1 LOW -VOLTAGE CABLE, 22/2 22/2-CL2P MECHANICAL 1 LOW -VOLTAGE CABLE, 22/8 22/8-CL2P MECHANICAL new INTERIORS LTD Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 • 1946 F. 860 • 678 • 7111 nidesign@nidesign.net © 2013 CONSULTANTS HED CEILING CURRENT SENSING SWITCH\ OUTSIDE AIRID,/� OUTSIDE* AIR SENSOR SUPPLY AIR DUCT SENSOR 12035 COLWICK Project Management* Design SAN ANTONIO, TX 78216 SMOKE DETECTOR EMS -3 4 sTA AREAEA 6 EMS -7 EMS -16 1 EMS -2 ------1 , EMS -5 - ----- 1 EMS -6 ZONE DAMPER L_i:Ii-1T_ EMS -9 jEMS1 0 20 SPACE SENSOR STORAGE RACEWAY STUB UP 8' AFF OR AS REQ'D BY NEC CAT -5 8 EMT 0 EMS -1 Room Controller RC642D Sales A Lights EMT 17 EMSP PB PB PB Storefront Signs • PB PB OI EMS PANEL 24"H X 24'W DRAWING CHRONOLOGY: index: date: description: 5 . 6 . 13 ISSUED TO CLIENT FOR FINAL REVIEW 5 .1 .13 ISSUED TO LANDLORD FOR FINAL REVIEW 5.10.13 ISSUED FOR BID 4 PERMIT Vi 8 . 2 . 13 REVISED PER RTU SPECIFICATIONS TITLE: EMS -8 20 SPACE SENSOR SALES NOTES MECHANICAL CONTRACTOR SHALL INSTALL ALL OWNER FURNISHED HVAC EQUIPMENT AND CONTROLS PER THE BILL OF MATERIALS AND RESPONSIBILITY MATRIX ON THIS SHEET. THIS INCLUDES ANY FIELD INSTALLED ACCESSORIES TO THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER INSTALLATION OF THE HVAC EQUIPMENT, ACCESSORIES AND CONTROL WIRING IN ACCORDANCE WITH DRAWINGS. THE MECHANICAL CONTRACTOR WILL BE RESPONSIBLE FOR PROPER TERMINATION OF CONTROLS AND PERFORMING A REMOTE SITE STARTUP WITH CARRIER. 2. REVIEW DETAILED INSTALLATION INSTRUCTIONS AND CONFIRM INSTALLATION LOCATIONS FOR ALL HVAC EQUIPMENT, DUCTWORK, DIFFUSERS, CONTROLS ETC. WITH THE GENERAL CONTRACTOR SUPERINTENDENT AND YGG PROJECT MANAGER DURING THE FIRST WEEK OF CONSTRUCTION (AFTER DEMO WORK IS COMPLETE). THE PURPOSE 15 TO VERIFY ALL WORK GAN BE INSTALLED AS PER THE DRAWINGS. 3. FAILURE TO MENTION ANY SPECIFIC ITEM OR DEVICE DOES NOT RELIEVE THE MECHANICAL CONTRACTOR OF THE RESPONSIBILITY FOR INSTALLING OR PROVIDING SUCH DEVICES OR ITEMS IN ORDER TO ACHIEVE THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. 4. MECHANICAL CONTRACTOR 15 RESPONSIBLE FOR INSTALLING TEMPERATURE CONTROL SYSTEM WIRING AND DEVICES AS PROVIDED BY YGG/CARRIER. THIS DRAWING 15 PROVIDED FOR 5117 PURPOSES, DETAILED CONTROL DRAWINGS FOR THIS PROJECT WILL BE PROVIDED WITH THE CONTROL DEVICES. 5. MECHANICAL CONTRACTOR SHALL PERFORM THE STARTUP OF THE CONTROLS WITH CARRIER VIA REMOTE SITE GONNEGTION. ALL ITEMS MUST BE COMPLETED ON THE START-UP READINESS FORM PROVIDED BY CARRIER BEFORE REMOTE STARTUP. ALLOW 2-3 DAYS LEAD TO SCHEDULE THE STARTUP. 6. THE MECHANICAL CONTRACTOR WILL WORK ON SITE WITH REMOTE ASSISTANCE FROM CARRIER TO VERIFY OPERATION OF THE HVAC EQUIPMENT AND CONTROLS. 1. THE FOLLOWING ITEMS MUST BE COMPLETE BEFORE A COMPLETE CONTROLS START-UP GAN BE PERFORMED: - EMS PANEL INSTALLED - SENSORS AND CONTROLS INSTALLED AND TERMINATED - POWER TO THE EMS PANEL AND ALL HVAC EQUIPMENT - ALL EMS WIRING INSTALLED AND TERMINATED - ALL UNIT ACCESSORIES INSTALLED AND WIRED BY THE MECHANICAL CONTRACTOR - WORKING YGG LAN CONNECTED TO EMS PANEL. S. CONTACT CARRIER (678-7q1-5060) IF YOU HAVE ANY QUESTIONS ON HOW TO PERFORM THESE TASKS. q. STARTUP OF THE HVAG EQUIPMENT AND CONTROLS MUST BE COMPLETED BY MECHANICAL CONTRACTOR WITH REMOTE ASSISTANCE FROM CARRIER IN ADVANCE OF THE SCHEDULED PROJECT PUNCH DATE. 10. MECHANICAL CONTRACTOR SHALL VERIFY ALL EMSP LIGHTING CONTACTOR FUNCTIONS, OBSERVE GKTS UNDER CONTROL AND BE PREPARED TO REPORT ANY DEFICIENCY TO THE GENERAL CONTRACTOR. II. THE GENERAL AND MECHANICAL CONTRACTORS MUST PROVIDE ADEQUATE TIME AND NOTICE TO CARRIER FOR TIMELY COMPLETION. 12. AIR BALANCE CONTRACTOR SHALL COORDINATEWITHCARRIER WHEN AIR BALANCING THE SYSTEM. THIS INCLUDES BUT NOT LIMITED TO SETTING UP MINIMUM OUTSIDE AIR DAMPER REQUIREMENTS AND VAV BOXES. CARRIER WILL SET THE AIR FLOW READINGS FOR THE VAV BOXES A5 MEASURED BY THE AIR BALANCE CONTRACTOR. 13. FINAL ACCEPTANCE OF THIS CONTROL SYSTEM WILL NOT BE APPROVED UNLESS THE ABOVE PROCEDURE 15 FOLLOWED AND DOCUMENTED AND A CONTROL NUMBER 15 ISSUED BY CARRIER. IF ALL ITEMS ARE NOT COMPLETED YANKEE CANDLE WILL NOT APPROVE FINAL PAYMENT TO THE CONTRACTOR. 14. GG/MEGHANIGAL CONTRACTOR WILL PROVIDE IST YEAR WARRANTY RESPONSIBILITY (LABOR ONLY) FOR THE HVAG EQUIPMENT AND CONTROLS. 15. CARRIER SHALL PROVIDE THE EMS PANEL PRE -WIRED AND PROGRAMMED. THE ETHERNET CONNECTION 15 BY THE "LAN" CONTRACTOR. MOUNT EM5 PANEL A5 CLOSE TO ELECTRICAL PANEL BOARDS AS POSSIBLE. 0 ELECTRICAL CONTRACTOR SHALL PROVIDE RACEWAY AS REQ'D BY NEG TO SALES LIGHTS AND STOREFRONT LIGHTS/SIGNS. 17. ELECTRICAL CONTRACTOR SHALL PROVIDE RACEWAY AS REQ'D BY NEC FROM PANEL BOARD SALES LIGHTS AND STOREFRONT LIGHTS/SIGNS BRANCH CIRCUITS, EMS PANEL POWER IS ZONE DAMPER MUST BE NORMALLY OPEN (N.O.) ACTUATOR TO OPEN WITHOUT 24VAG AND CLOSE WITH 24VAG. Iq. SMOKE DETEGTOR(5) ARE AS REQUIRED AND INSTALLED BY OTHERS. CONNECTION 15 FOR MONITOR ONLY. €t SPACE SENSORS AND RC642D SHALL BE MOUNTED IN THE LOCATIONS SHOWN ON THE M -I01 SHEET. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 12 2013 City of Tukwila BUILDING DIVISION Mechanical Controls date: 8.2.13 drawn by: clg scale: AS NOTED PROJECT: 1\11VbqYri3 #644 Westfield South Center Seattle, WA space #: #204 sq. ff®: 1,647 jOb #: 13064 file: D CITY OF TUKWr Lq AUG 062013 PERMIT CENTER M.4 1 6C TO PROVIDE NF_11 FUSH BUTTON TO ee CONNECTED TO BUZZER AT STOCK/ALES WALL 911-6" - LEASE !DIMENSION 11'-0" 24'-O" 24'-O" 24'-0" Ey...e. ADJACENT TENANT ZOO #ffrffffi GF1 (1) / EXIT CORRIDOR I uj -Ne. A-23 181-0" 20'-O" 20'-10 1/2" Ar " Pffm" r=fig A-Icl" 1.11F,7 A-35/31/3qr [ A-21 51...6 II 12" 2' -IO" !Lip" 35"35" AFF•°T AFF MINN T r ":1""er LAN,VI EXTEND F.T. PLYWOOD BACKER BD. A5 REGD. FOR NEIN PANEL G Power Plan SCALE: 1/4" = 1'-0" A-5 NEIN BUZZER TO BE CONNECTED TO NEV' PUSH BUTTON AT SERVICE DOOR 18" 11 • t1,1 111 • • 01 rJ.Uflfdg. 11416i.loa. .1,1. 4,1.11 A -I1 11.<LAN:D1-174) A-1,41,11,13 T a Affe5 '„ff TIW „di" • ,t•• J • .1' 1111.• • • • kl 2111 . • 15" AFF ,wJwW7MfJWZ 11 11 II 1I-8" - A -I o A-3 f 1,11 40", .0 7777 77 7/777 7.7.7 .74/7 7777 7.77.7 7.71.77 " ArIZAFAr 7777 .777/7 AoV7777.7777 .7 777 .777 Jler4rArAir 4r wr#W "Ara, 4,r4r A -I4 ..ht r 101" AFF 1(1 20'-4" A -I6 Z ' ./Z ./ZZ, zffr,c7"17 Alf" aNd tau du, a',1E . , P1.4 4 - I' 107" Ha I it AFF1l AFFlii • J11-" ,„11„„ „A, TYP. FOR 4 161-0" 0 14'-10 1/2" A-15 MS 5 I ri \ 11 . • 111 Ha N:DIP2,03 VI ADJACENT TENANT "1116-ri ...-17 • --LI I h 1-4 101 h Oi 1 I 1 11 1 18" !I, AFF • I-;1 ifi •II, Ai ,, . • • • ,,,„,,,,,.,,,,,, I PIIII fiAll 1:1.111 H. 0 ' TN -WI I.. 1.v.1 1...4 lvir m n.. , , . .., . . 1 AFF • h h , ,----i..-- ...........,,...„,..,,,41,, it, . Ig.1 I AFF ic, • 01 .." .." . ArAgr" .r ,...eri• .0r.#// 4,.." ../ //./..-aof .e. _I/4r /../.0. / ./..///r //51 ler#. .".././ar..." " 0 I' 2' 4' 8' EXIT/EMERGENCY LIGHTING NOTE: THE GENERAL CONTRACTOR SHALL TEST AND VERIFY IN FIELD IF THE EXISTING EXIT AND EMERGENCY LIGHTING GAN BE REUSED. IF NOT, CONTACT YANKEE CANDLE COMPANY PROJECT MANAGER. FIRE ALARM NOTE: GENERAL CONTRACTOR MUST USE L/L'S APPROVED CONTRACTOR FOR THE FIRE ALARM DESIGN, PERMITTING, AND INSTALLATION. DEMOLITION NOTE THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR THE REMOVAL OF ALL ELECTRICAL DEVICES, EQUIPMENT, ASSOCIATED CONDUIT/PIIRE, ETG. NOT BEING REUSED. DO NOT ABANDON IN PLACE. REFER TO ARCHITECTURAL ni DEMOLITION PLAN. ADJACENT TENANT LOW VOLTAGE NOTES: I. THE GENERAL CONTRACTOR SHALL PROVIDE APPROPRIATE CONDUIT FOR ALL LOIN VOLTAGE WIRING AS REQUIRED BY ALL LOCAL GOVERNING CODES. IT 15 THE SOLE RESPONSIBILITY OF THE G.C. TO VERIFY LOCAL CODE REQUIREMENTS AND COMPLY AS REQUIRED. 2. THE GENERAL CON -TRACTOR 15 RESPONSIBLE FOR ACQUIRING LOIN VOLTAGE PERMIT AS REQUIRED BY APPLICABLE LOCAL GOVERNING MUNICIPAL AGENCIES. 3. ALL. LOW VOLTAGE WIRE RUNS TO BE CONTINUOUS, NO SPLICING ALLOWED. IMPORTANT NOTE: REFER TO ARCHITECTURAL A.4 REFLECTED CEILING PLAN FOR DIMENSIONS A-8 -et -r,"" 41 1.. A-2 RI /i EXIT CORRIDOR IE1 RI Lighting Plan SCALE: 1/4" =11-0" nay INTERIORS LTD 4"..f w#,rizoty ...f." .reer,edezrz. ADJACENT TENANT 0 I' 2' 4' 8' Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860- 678 • 1946 F. 860 • 678 • 7111 nidesign@nidesign.net 2013 CONSULTANTS Project Management * Design 12035 COLWICK SAN ANTONIO, TX 78216 (::::HRIONOLOGY: lindex: date: descdplion: 5. 6 ISSUED TO CLIENT FOR FINAL REVIEW 5 . 1 . 13 ISSUED TO LANDLORD FOR FINAL REVIEW 5 . 10 . 13 ISSUED FOR BID 4 PERMIT SEP, 1\140 •1740\IN1 O"fe: 5 . 10 . 13 drawn by: cig Electrical Plans SCONCE LIGHT FIXTURE, CENTER SCONCE AT 1'-6" A.F.F. ON FACE OF MILLWORK COLUMN (TYP. OF 2) SCO le: AS NOTED 0 SHEET NOTES I. HE SALES AREA TRACK LIGHTING SI -FALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E.2. 2. NEIN SALES AREA LIGHTING SHALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E.2. 3. STOREFRONT LIGHTING FIXTURES SHALL BE ROUTED 'THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E.2. 4. STOREFRONT SIGN GIRCUIT(5) SHALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E.2. 5. POWER FOR SIGN TO BE, LOCATED ABOVE CEILING, COORDINATE FEED TO STOREFRONT WITH'SIGN CONTRACTOR ELECTRICAL CONTRACTOR TO MAKE FINAL CONNECTION TO SIGN. 6. PROVIDE NEW WALL MOUNTED OCCUPANCY SENSOR SWITCH MODEL MN5D IN/ MANUAL OVERRIDE SWITCH FOR STOCKROOM LIGHTING. REFER TO MANUFACTURER'S SPECIFICATIONS FOR FURTHER INFORMATION. 1. REMOVE EXISTING, PROVIDE NEW WALL MOUNTED OCCUPANCY SENSOR SWITCH MODEL 4* VW FOR TOILET LIGHT/FAN FIXTURE. REFER TO MANUFACTURER'S SPECIFICATIONS FOR FURTHER INFORMATION. REFER TO DETAIL 8. NIGHT LIGHTING, EXIT SIGNS AND EMERGENCY EGRESS LIGHT FIXTURES SHALL. SE CONNECTED TO CIRCUIT BREAKER(S) WITH LOCK -0N DEVICES, LOCKED IN THE "ON" POSITION. WIRE NEIN 1"in EXISTING. cf. TRACK LIGHTING SHALL BE PROVIDED 4ITH CURRENT LIMITING DEVICES IN THE WATTAGES A5 INDIGAIEI.) ON THE DRAWINGS TO MEET IEGG REQUIREMENTS FOR ENERGY CONSUMPTION ASSOCIATED WITH LIGHTING. HIRE THROUGH LIGHTING CONTROL PANEL "EMS", REFER TO DETAIL I/E.2 10. SPEAKERS AND SPEAKER WIRE SHALL BE PROVIDED AND INSTALLED BY YCG VENDOR. 11. PROVIDE QUAD OUTLET, STORE PHONE (VI) AND LAN DI TO SERVER. TELEPHONE AND DATA SHALL BE IN A COMMON DEVICE BOX. SEE DETAIL 6/A.5. 12. ELECTRICAL CONTRACTOR SHALL INSTALL (2) DUPLEX RECEPTACLES AND TELEPHONE/DATA JACKS MOUNTED 0 A.F.F. TO SERVE CASHIAIRAP EQUIPMENT. TELEPHONE/DATA SHALL BE COMBINED IN THE SAME BOX. MILLWORK TO BE MODIFIED FOR ACCESS IN THE SIDE FOR CONNECTION OF EQUIPMENT TO RECEPTACLES AND TELEPHONE/DATA JACKS. PROVIDE '(2) 3/4" CONDUITS TO PHONEBOARD FOR TELEPHONE/DATA CABLING. ELECTRICAL CONTRACTOR TO RUN (3) GAT 5 LINES WITHIN CONDUIT'S BACK TO SECURITY CLOSET AND TERMINATE IN LINKSYS ROUTER. 13. ELECTRICAL DISTRIBUTION EQUIPMENT 15 EXISTING AND SHALL BE REUSED / RELOCATED. TO REMAIN. MODIFY A5 REQ'D. 14. LIGHTING CONTROL PANEL "EMS" 15 NEW, FURNISHED BY YGC VENDOR, INSTALLED BY TENANT'S ELECTRICAL CONTRACTOR. SEE DETAIL I ON SHEET E.2 FOR ADDITIONAL INFORMATION ASSOCIATED WITH THE LIGHTING CONTROL PANEL. 15. SECURITY SHELVING INSTALLED BY GENERAL CONTRACTOR. DEVICES INCLUDING POWER OUTLETS, LAN DI -124 QUAD DATA JACK lEiMINAL, AND A DUPLEX TELEPHONE JACK (VI AND V3) PER DETAIL 2 ON e--ACET E.2. PROVIDE FIRE RATED BACKBOARD FOR MOUNTING OF SECURITY, LAN, SPEAKER, AND POWER EQUIPMENT. 16. MOUNT RECEPTACLES LOCATED Af3OVE HUTCHES HORIZONTALLY AT 8'-8" AFF 50 THAT k1‘5 NOT VISIBLE FROM THE SALES FLOOR. SHALL BE ROUTED THROUGH LIGHTING CONTROL PANEL "EMS", SEE DETAIL I ON SHEET E.2. 11. SECURITY SYSTEM DEVICES, CAMERAS, AND MONITORS ARE SUPPLIED BY TENANT. ELECTRICAL CONTRACTOR SHALL INSTALL I" CONDUIT TO SECURITY SHELVING FOR EACH DEVICE. COORDINATE EXACT LOCATION WITH YGG 'PROJECT MANAGER PRIOR TO INSTALLATION. 18. PROVIDE POWERFOR NEW UNDER -COUNTER INSTANTEOUS ELECTRIC INA1-ER HEA 1 B.4. Iq. PROVIDE NEW ELECTRICAL CONNECTION AND CIRCUITRY FOR ROOF TOP UNIT - 208 VOLT,,3 PHASE, ????A. ELECTRICAL CIRCUITRY SHALL CONSIST OF (3) #??? GU. 20. PROVIDE NEW CIRCUITRY FOR DUPLEX RECEPTACLE AT ROOF TOP UNIT FOR SERVICING OF EQUIPMENT. 21. CEILING SMOKE DETECTOR 15 NEIN AND SHALL BEWIRED WITH AND COMPATIBLE WITH FIRE ALARM SYSTEM. 22. FIRE ALARM NOTIFICATION DEVICE 15 NEN AND SHALL BE WIRED WITH AND COMPATIBLE WITH MALL FIRE ALARM SYSTEM BY MALL REQUIRED MALL FIRE ALARM CONTRACTOR. Mk3,078 CURRENT LIMITER SPECIFICATIONS NUMBER OF TRACK HEADS PER CIRCUIT DETERMINES SIZE OF CURRENT LIMITER. GALGS BASED ON 161N PER 'TRACK HEAD. EQUATION: CLD SIZE = # TRACK * TRACK HEAPS 1-5 6-14 I5 -2q 30-44 45-5q 60-11 HEADS x FIXTURE WATTS x 1.25 C1.17 PART MAX WATTS MAX AMPS RE61-11 RE65-1N RE66-1N REGq-1N RE610-11 REG12-1N 120 1 300 600 q00 1200 1440 2.5 5 1.5 10 12 1:::"ROJECT: #644 RECEIVED CITY OF TUKWILA MAY 3 0 2 013 PERMIT CENTER 1 E.1 CONTRACTOR TO REMOVE SWITCH COVER AND REPLACE AFTER ADJUSTING SENSOR SETTINGS TO CENTER POSITION AS SHOWN. OCCUPANCY SENSOR SCALE: NO SCALE Westfield South Center Seattle, WA ri 1,647 ph #: 13064 51:101]::1Ce #: #204 • STAj7I}EMIC'R‘F( t\i.,s.1,1:1:5,111i/iEsiGRTF.30N Ao" 11 k ommumm!,,,,...:m,d,,Hmmmullmmaand,inonummoolord.m.monnqvmdlmonc:', E.1 GENERAL POWER & LIGHTING NOTES A. UNLESS NOTED OTHERWISE, ALL LIGHT SWITCHES ARE 48" AFF. B. UNLESS NOTED OTHERWISE, ALL HEIGHTS ARE TO CENTER OF DEVICE. C. ALL STEREO EQUIPMENT FURNISHED BY THE TENANT AND INSTALLED BYTENANT'S CONTRACTOR IN SECURITY SHELVING AND IN THE CEILING. D. PROVIDE 3/4" CONDUIT 01111-i PULL WIRE FROM EACH THERMOSTAT, TELEPHONE, LAN OR SECURITY DEVICE BACK TO THE SECURITY SHELVING. PROVIDE BUSHING ON THE END OF ALL CONDUIT. E. ALL LAN (DATA) OUTLETS AND TELEPHONE OUTLETS SHALL BE CLEARLY IDENTIFIED AS SUCH, I.E. "VI", "DI", ETC. F. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL CONDUIT AND INIRE REQUIRED TO MAINTAIN CONNECTIONS TO THE MALL MANAGEMENT CONTROL SYSTEM(5). FIELD VERIFY REQUIREMENTS WITH TENANT COORDINATOR PRIOR TO CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL RUN ALL TENANT PROVIDE LAN CATEGORY 5E COMPUTER INIRING, JACKS AND PROVIDE FINAL CONNECTIONS. THE ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR CONDUIT AND JJNCTION 130XES AS REQUIRED. H. ALL UNUSED ELECTRICAL CONDUIT AND WIRING SHALL BE REMOVED AND DISPOSED OF. THIS SHALL INCLUDE ALL HANGING AND SUPPORT MATERIAL A5 WELL. I. ELECTRICAL CONTRACTOR 15 RESPONSIBLE FOR ALL ELECTRICAL AND LOH VOLTAGE PERMITS. EMS PANEL L5X 12 -------RE1712 WHT 12 GHD 12 POWER CONNECTIONS 120V POWER 120V POWER 120V POWER EARTH GROUND NOTE: FOR REFERENCE ONLY. THE EG SHALL COORDINATE WITH THE AUTOMATED LOGIC EMS PANEL SHOP DIRAWINGS. TO LOADS I Ho LATCH LIF -0 UNLATCH 1.2 SALES MONOPOINTS AND RECESSED LIGHTING 1 0-A:6 J. ALL LIGHTING FIXTURES AND OCCUPANCY SENSOR SWITCHES ARE FURNISHED By TENANT THRU CAPITOL LIGHT. K. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL REQUIRED EQUIPMENT DISCONNECT SWITCHES FOR. HVAC., PLUMBING, ETC. EQUIPMENT. L. SALES FLOOR LIGHTING, STOREFRONT LIGHTING AND SIGN LIGHTING SHALL BE CONTROLLED BY LIGHTING CONTROL PANEL "EMS". SEE DETAIL 1 ON SHEET E.2. M. LIGHT FIXTURES LABELED "NITE" SHALL BE NIGHT LIGHTS. N. LIGHT FIXTURES, DEVICES, ETC. LABELED "EX" ARE EXISTING TO REMAIN. 0. LIGHT FIXTURES, DEVICES, ETC. LABELED "EX/R" ARE EXISTING TO BE RELOCATED AS INDICATED. P. ALL EXIT, EMERGENCY, AND NIGHT LIGHT FIXTURES SHALL BE GONNEC 1E) AHEAD OF ANY SNITCHING OR CONTROLS. 0. THE TENANT'S ELECTRICAL CON -TRACTOR SHALL INCLUDE ALL GO5T5 ASSOCIATED WITH THE LANDLORD'S FIRE ALARM SYSTEM A5 REQUIRED. THE TENANT'S ELECTRICAL CONTRACTOR SHALL INCLUDE ALL COSTS ASSOCIATED WITH FIRE ALARM DRAWINGS, PERMITS, EQUIPMENT PURCHASE AND SYSTEM PROGRAMMING/INSTALLATION. NOTE: FIRE ALARM PANEL TO BE UPGRADED TO SIMPLEX # 4001. 2444 stim-i '.611VONINIM -V01,14AVeig. Lt'IMIMPIOPM:00 :104,_410.0010.W.4401PROM4F.M94VAPAVAPPRORWAW110 IONMaggPiNIMMiER-:' #0.14:144fiVA,244,1,1',40,1,01110 ...,k0,449414061, AMC!' 414 torNtkifie.,=,..NP *=. 11111.M. 1.141:W.,==.1.0 TO LOADS I Ho LATCH LI Ho UNLATCH 0 6 TO LOADS 1 tNk,(KMAIN.CAVAVeli4114404 _210_01' LATCH IHo Li UNLATCH 1.3 1.4 STOREFRONT SIGNS SHOW WINDOW LIGHTING AUTOMATED LOGIC CONTROLS EMS E.2 SCALE: NO SCALE Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 • 1946 F. 860 • 678 • 7111 nidesign@nidesign.net © 2013 SECURITY SHELVING NOTES: 1. G.G. TO PROVIDE 1" CONDUIT FROM EXISTING TELEPHONE SERVICE MAIN TO SECURITY SHELVING UNIT LOCATION 2. G.C. TO PROVIDE POWER AT THIS LOCATION A5 SPECIFIED AND POWER MUST BE ACTIVE PRIOR TO SECURITY EQUIPMENT CONTRACTOR'S INSTALLATION. 3. G.G. MUST BE ON SITE TO RECEIVE SECURITY EQUIPMENT DELIVERY. 0 0 z z 0 To 0 0 LOADS 1 WIRING BY CONTR. (TYP) LATCH I Ho Li UNLATCH 1.5 HUTCH LIGHTING °A:12 0--A:14 SURFACE MOUNTED DOUBLE DUPLEX RECEPTACLES FRT PLYWOOD BACKBOARD ALL DEVICES SHALL BE SURFACE MOUNTED CONSULTANTS 12035 COLWICK Project Management * Design SAN ANTONIO, TX 78216 YANKEE CANDLE COMPANY - SEATTLE, WA NEC LOAD ANALYSIS AT EXISTING 200 AMP 120/208V/3W/4W ELECTRICAL SERVICE ITEM CONN. LOAD (VA) DEMAND F. DEMAND LOAD (WATTS) TOTAL (AMPS) LIGHTING 2410.0 125% 3112.0 , FIRST IOKW REGEPT 6620.0 100% 6620.0 REMAINING REGEPT 0E1 50% LIGHTALARM5 HATER HEATERS 150.0 100% 150.0 MISC. LOADS 540.0 100% 1 540.0 HVAC LOADS c1000.0 I00% 1000.0 SUB -TOTAL 11400.0 2 20022.0 25% OF LARGEST MOTOR 115.0 25% 115.0 TOTAL @ 120/2013V 3PH INTERIOR MALL SCONCE FORGHUBBARTONE 20111.0 56.1 Lighting Fixture Schedule Sym. Description Mfg Model Lamp A V SALES FLOOR HEAD CONTEGH GTL603A-P-20W TGP LEDI1E26P3830KNFL LED I1W PARSE) FLOOD - 3000K D1 V SALES FLOOR MONOPONT GONTEGH CTL603A-P-2011 4 LAI8P 8FWKLOONDFL- 311170001-1K1 pTGAPR3L8EDNAI1E2RR0671 0E1 LED INHITE THERMOPLASTIC EXIT 516N LIGHTALARM5 NAGILXN500R-N 120 LED (INCLUDED) 1 COMBINATION BATHROOM EXHAUST FAN AND LIGHT BROAN 616 100100V4 CFL FL G 0 6" RFGESSED DOINNLIGHT WITH -WHITE TRIM CONTECH RL38-20W 4 CTR3001-44T TGP LEDIGIE26P31330KNFL LED I1W FAR38 FLOOD - 3000K 2 CHAIN HUNG LT.5' FIXTURE AT STOCKROOM MERCURY MM-232-OGT-G-ELBL-UNI PHILIPS F32T8/ADV1335/XLL (2) L FOR' INTERIOR MALL SCONCE FORGHUBBARTONE 20-6251 120 PHILIPS 2B10 1/2 END/CL 2100K X2 IIIF-4111 SALES FLOOR 2 -HEAD CLG. MOUNTED EM. LIGHT FIXTURE WITH INTEGRAL BATTERY GONTEGH EL2HAIOIN SELF CONTAINED HALOGEN LAMP ,..7 X1 I'l STOCKROOM 2 -HEAD EMERGENCY LIGHT PACK LIGHTALARMS LGA -250 120 5.4 WATT HALOGEN (INCLUDED) vi RJ11 V3, V1 9 0 0 RJ11 TO CASHWRAP TO MANAGER'S DESK D1, D2 D3, RJ45 ( TO CASHWRAP SECURITY MULTIPLEXER t I 11;11.11 1.1 0 SECURITY MONITOR 0 C.1 [TT/ 7""-;;;' 0 0 2 ROUTER STEREO EQUIPMENT FAX/COPY/ PRINTER 2 E.2 SECURITY SHELVING ELECTRICAL LAYOUT SCALE: NO SCALE DRAW NID CNrinik linc 5 . 6 . 13 5 . 1 . 13 5 . 10 . 13 OLOGY: clescruption: ISSUED TO CLIENT FOR FINAL REVIEW ISSUED TO LANDLORD FOR FINAL REVIEW ISSUED FOR BID 4 PERMIT EXISTING PANEL "A" PANELBOARD SCHEDULE 120/208V 3PH 4W CONNECTED VOLT -AMPS LOAD SERVED CKT * GKT BKR WHASE IRE SIZE PHASE A PHASE 5 PHASE G PHASE PHASE A PHASE 13 PHASE G IIIRE SIZE GKT BKR OKT * SERVED GASH REGISTER 1 20 #I2 300 100 #12 20 2 TRACK LTG GASH REGISTER 3 20 *t12 300 650 #12 20 4 TRACK LTG MGR'S DESK REGEPTS 5 20 #12 360 380 4t12 20 6 SALES LTG LAN REGEPTS 1 20 #I2 360 540 #I2 20 8 SIGNS/SCONCES LAN REGEPTS q 20 #12 360 210 #I2 20 10 STOREFRONT LTG LAN REGEPTS II 20 #I2 360 650 #I2 20 12 STKRM/TOILET LTG LAN REGEPTS 13 20 #12 360 100 *12 20 14 HUTCH REGEPTS SHOW ININ./SALE5 REGEPTS 15 20 itI2 120 500 itI2 20 16 HUTCH REGEPTS REFIGERATOR 11 20 #I2 200 600 4t12 20 18 SPARE SALES AREA REGEPT/BUZZER 11 20 #12 280 100 #I2 20 20 LIGHTING CONTACTOR (EMS) HVAG SERVICE REGEPT 21 20 #I2 360 100 #I2 20 22 CONTROLS GATEWAY (EMS) WATER HEATER 23 20 #I2 150 200 #12 20 24 FIRE ALARM PNL SPARE 25 20 #12 180 20 26 SPARE SPARE 21 20 #I2 180 20 28 SPARE SPARE 21 20 20 30 SPARE SPARE 31 20 20 32 SPARE SPARE 33 20 20 34 SPARE RTV-I 35 i*e) 3000 20 36 SPARE 3'7 40 it8 3000 38 SPACE 31 tte, 3000 40 SPACE SPACE 41 42 SPACE TOTAL PHASE A 4480 2040 6520 TOTAL PHASE 5 4120 1460 6380 TOTAL PHASE G 4610 1830 6500 TOTAL VOLT -AMPS 11400 DIVIDE TOTAL VA BY VOLTAGE 208 LINE TO LINE VOLT AMPS 13.26 DIVIDE TOTAL AMPS BY 3 PHASE MULTIPLIER 1.132 3 PHASE AMP 53.88 TOTAL CONNECTED LOAD 53.88 150 AMP M.L.O. PANEL FEEDER SIZE - EXISTING - SEE RISER DIAGRAM GENERAL RISER NOTES A. ELECTRICAL CONTRACTOR SHALL ENSURE COMPLIANCE WITH NEC 11026 SPACES ABOUT ELECTRICAL EQUIPMENT AND NEC 408.0 CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION. B. PROVIDE BREAKER LOCK -ON DEVICE FOR CIRCUIT BREAKERS SERVING EXIT AND EMERGENCY LIGHTING, SECURITY PANEL DEVICES AND GASH WRAP RECEPTACLES. C. PROVIDE TYPE -RI i 1EN CIRCUIT DIRECTORY FOR ALL ELECTRICAL PANELS. 17. PROVIDE PLACARD FOR EACH PIECE OF ELECTRICAL DISTRIBUTION EQUIPMENT INDICATING EQUIPMENT DESIGNATION, SYSTEM VOLTAGE AND PHASE INDICATION. E. ELECTRICAL EQUIPMENT SHALL SE FIELD MARKED TO WARN OF POTENTIAL ARG FLASH HAZARDS DURING MAINTENANCE PER NEC 110.16. LANDLORD'S ELECTRICAL ROOM YANKEE CANDLE COMPANY SPACE (4) *4/0 GU (1) #6 GROUND 2-1/2" CONDUIT (EXISTING) LANDLORD'S EXISTING DISTRIBUTION EQUIPMENT 150A SW 0 SHEET NOTES I. ELECTRICAL METERING EQUIPMENT, DISTRIBUTION EQUIPMENT AND ASSOCIATED ELECTRICAL FEEDERS ARE EXISTING TO REMAIN. ELECTRICAL CONTRACTOR SHALL PROVIDE ANY REQUIRED CIRCUIT BREAKERS PER THE PANEL SCHEDULE ON THIS SHEET. CONTRACTOR TO LABEL DISCONNECT AND METER WITH TENANT NAME AND ADDRESS (SPACE #204). 2. LIGHTING CONTROL PANEL "EMS" 15 NEW, PROVIDED BY YCC VENDOR, INSTALLED BY ELECTRICAL CONTRACTOR. 3. NEW (REMOVE EXIST) 40A/3P UNFUSED W.P. DISCONNECT AND CONDUCTORS 61 NEW RTU. CONTRACTOR TO LABEL UNIT AND DISCONNECT WITH TENANT NAME AND ADDRESS (SPACE #204). 4. NEV FIRE ALARM CONTROL. PANEL - TO BE SUPPLIED AND INSTALLED BY MALL REQUIRED FIRE ALARM CONTRACTOR. G.C. TO COORDINATE. M.S.0 120/ 208V SPH 4W 200A SIN 150A FU (EXIST) (3) #8 GU c?) (I) #10 GU GROUND I-1/4" CONDUIT (NEW) PANEL "A" 120/208V 3PH 4IN 150A MLO 42 SPACE (EXISTING) (4) #4/0 GU @(1) *6 GROUND 2-1/2" CONDUIT (EXISTING) t3-07 g NEIN LIGHTING CONTROL PANEL "EMS" LIGHTING CIRCUITRY NEIN FACP Electrical Schedules titer: 5 0. 13 and Risers drawn by: clg. sccde: AS NOTED 3 ELECTRICAL RISER DIAGRAM E.2 SCALE: NO SCALE #644 Westfield South Center Seattle, WA space #: #204 sq.ft„: 1,647 ob 13064 fi 10: RECEIVED CITY OF TUKWILA MAY 3 2013 PERMIT CENTER .0ininoott.tanumamr., 01111i1:01.. 4869 JIMMY L. PO STATE OF WA iiinummummtorummoc:nummuilmilmmwraitmotommumwmanuannwmiNi:T E.2 Design new INTERIORS LTD Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 - 1946 F. 860 • 678 • 7111 nidesign@nidesign.net © 2013 CONSULTANTS 12035 COLWICK Project Management* Design SAN ANTONIO, TX 78216 6"° G6RIPANliIRON I� ii 61�,.R u��iVtall� 5.6.13 5.1.13 5.10.13 lit„rt' �l"BB�Y iP"II�Q Ia F,HIN e II 16 �;n � i iflr ��,� ISSUED TO CLIENT FOR FINAL REVIEW ISSUED TO LANDLORD FOR FINAL REVIEW ISSUED FOR BID 8 PERMIT TENANT CRITERIA AND LANDLORD NOTES • THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO OBTAIN A COPY OF THE MALL'S TENANT CRITERIA HANDBOOK. • THE ELECTRICAL INSTALLATION MUST MEET ALL REQUIREMENTS OF THE NATIONAL ELECTRICAL GORE, LOCAL AUTHORITY HAVING JURISDICTION AND LANDLORD'S INSURANCE PROVIDER(5). • NO APPURTENANCES (INCLUDING LIGHT FIXTURES, ANTENNAS, SIGNS, ETC.) SHALL BE AFFIXED TO THE EXTERIOR WALLS OR ROOF OF LANDLORD'S BUILDING WITHOUT PRIOR APPROVAL FORM THE TENANT REVIEW COORDINATOR. • SPECIAL CARE MUST BE TAKEN TO PROTECT SHOPPING CENTER FLOORING, DOORWAYS, AND CEILINGS. ALL CARTS, DOLLIES, ETC., MUST HAVE RUBBER WHEELS. WHEELBARROWS OR OTHER WHEELED VEHICLES WITHOUT RUBBER WHEELS ARE STRICTLY PROHIBITED. ANY DAMAGE REPAIRS OR CLEANUP OF DEBRIS WHICH MUST BE HANDLED BY LANDLORD SHALL BE AT THE SOLE COST AND EXPENSE OF TENANT, PLUS A 20% ADMINISTRATIVE FEE. • LOUD NOISES WILL NOT BE TOLERATED DURING SHOPPING CENTER HOURS. • NO ONE 15 ALLOWED ON THE SHOPPING GEN i tib ROOF WITHOUT PRIOR WRITTEN APPROVAL FROM LANDLORD. • CONTRACTOR MUST RECEIVE PRIOR PERMISSION OF LANDLORD FOR WORK AFTER NORMAL WORKING HOURS. • CONTRACTOR, AND EMPLOYEES MUST PERFORM WORK IN A PROFESSIONAL MANNER. UNPROFESSIONAL BEHAVIOR, (I.E., PROFANITY, SPITTING, ETC.), WILL NOT BE TOLERATED AND WILL RESULT IN THE SHUT -DOWN OF THE JOB SITE UNTIL THE UNPROFESSIONAL GONTRAGTOR/EMPLOYEE 15 REMOVED AND NEW CONTRACTOR/EMPLOYEE 15 EMPLOYED. ALL CONSTRUCTION PERSONNEL ARE REQUIRED TO WEAR SHIRTS AND SHOES AT ALL TIMES. • LANDLORD AND LANDLORD'S AGENT RESERVES THE RIGHT TO STOP WORK IN PROGRESS FOR VIOLATIONS OF THE RULES AND REGULATIONS. • ACCESS TO LANDLORD'S SWITCHGEAR IS RESTRICTED AND MUST BE SCHEDULED WITH SHOPPING CENTER MANAGEMENT. INTERRUPTION OF POWER TO EXISTING TENANTS MUST HAVE LANDLORD'S PRIOR APPROVAL • ALL SIGN, LOGO AND SHOW WINDOW ILLUMINATION MUST BE CONTROLLED BY AN AUTOMATIC TIMEGLOGK. • NIGHT LIGHTING SHALL BE DESIGNED AND INSTALLED, RESULTING IN LOW LEVEL ILLUMINATION THROUGHOUT THE SPACE WHEN THE STORE IS CLOSED. • TENANT'S ELECTRICAL SYSTEM SHALL BE GROUNDED TO STEEL STRUCTURE PER THE NATIONAL ELECTRICAL GORE. TENANT'S CONTRACTOR SHALL REPAIR STEEL FIREPROOFING (IF APPLICABLE). • TENANT SHALL PROVIDE AND INSTALL A COMPLETE ELECTRICAL SYSTEM AND PERFORM ALL REQUIRED WORK WHICH MAY INCLUDE, BUT 15 NOT LIMITED TO, FUSED DISGONNEGT SWITCH, METER PAN AND SOCKET, METER, CONDUIT AND WIRE FROM LANDLORD'S DESIGNATED DISTRIBUTION POINT TO AND WITHIN THE PREMISES, AND ALL WIRING AND CONNECTIONS FROM THE CENTRAL DISTRIBUTION PANELS, LIGHTING PANELS, ALL FEEDER CONDUCTORS, ANY REQUIRED TRANSFORMERS, ALL CONDUIT AND WIRING FOR POWER DISTRIBUTION WITHIN THE LEASED PREMISES, LIGHTING FIXTURES, RECEPTACLES, SWITCHES AND MISCELLANEOUS DEVICES REQUIRED WITHIN THE PREMISES. • ALL ELECTRICAL WORK WILL CONFORM TO BUILDING DESIGN PARAMETERS AND ALL APPLICABLE GOVERNMENTAL REGULATIONS INCLUDING ENERGY CONSERVATION GODES. WHERE PREVIOUSLY EXISTING ELECTRICAL COMPONENTS ARE TO BE REUSED, TENANT ACCEPTS ALL EXISTING ELECTRICAL COMPONENTS IN AN "A5 -IS CONDITION AND WILL REPLACE, REPAIR OR REFURBISH THESE COMPONENTS TO A "LIKE -NEW” CONDITION ADEQUATE FOR THE OCCUPANCY OF THE PREMISES AND COMPLIANT WITH BUILDING DESIGN PARAMETERS AND ALL GOVERNMENTAL REGULATIONS. • ALL MODIFICATIONS TO THE EXISTING SYSTEM WITHIN THE DEMISED PREMISES SHALL BE BY TENANT'S CONTRACTOR. TENANT'S CONTRACTOR AGGEPTS EXISTING SYSTEM IN "AS -IS" CONDITION AND 15 RESPONSIBLE FOR DETERMINING THE ADEQUACY OF ANY EQUIPMENT OR SYSTEM WHICH TENANT'S CONTRACTOR GH005E5 TO REUSE. ANY EQUIPMENT OR SYSTEM COMPONENTS WHICH TENANT'S CONTRACTOR INTENDS TO USE OR REUSE SHALL BE CLEARLY DESIGNATED AS SUCH ON TENANT'S DRAWINGS. • INSTALLATION SHALL CONFORM TO THE FOLLOWING: A. ELEGTRIGAL PANELS SHALL HAVE COPPER BUS BARS AND BOLT -IN BREAKERS. LOAD CENTERS ARE NOT PERMITTED. THE NATIONAL ELECTRICAL CODE REQUIRES THAT LIGHTING PANELS CONTAIN CIRGUIT BREAKERS RATED FOR SWITCHING DUTY. B. PANEL BOARDS SHALL BE DESIGNED FOR A MINIMUM OF 25% EXCESS CAPACITY BASED ON CONNECTED LOAD. TENANT SHALL PROVIDE 20% SPARE BREAKER SPACE. • ENGRAVED, MECHANICALLY ATTACHED NAME PLATES SHALL BE INSTALLED ON EACH PANELBOARD, TRANSFORMER, DISGONNEGT SWITCH, MOTOR STARTER, ETC. • A CONVENIENCE RECEPTACLE AND SWITCHED LIGHT FIXTURE SHALL BE INSTALLED ADJACENT TO ALL ROOF MOUNTED MEGHANIGAL EQUIPMENT. • TENANT SHALL PROVIDE CONDUIT AND WIRING FOR THE PROVISION OF TELEPHONE AND GABLE (IF AVAILABLE) SERVICE TO THE LEASED PREMISES FROM THE LANDLORD'S DESIGNATED TELEPHONE UTILITY DISTRIBUTION PANEL TO AND WITHIN THE PREMISES. TENANT SHALL FURNISH AND INSTALL ALL TELEPHONE AND GABLE EQUIPMENT, CONDUIT AND WIRING, OUTLET BOXES AND DEVICES WITHIN THE LEASED PREMISES. TENANT SHALL MAKE ALL NECESSARY ARRANGEMENTS DIRECTLY WITH THE APPROPRIATE TELEPHONE AND GABLE SERVICE PROVIDER(S). ALL TELEPHONE WIRE AND GABLE OUTSIDE OF THE LEASED PREMISES SHALL BE ROUTED THROUGH CONDUIT FROM THE APPLICABLE UTILITY DISTRIBUTION POINT TO AND WITHIN THE PREMISES BY THE TENANT. ALL TELEPHONE AND GABLE WIRING IN THE PREMISES SHALL BE PLENUM RATED. • ALUMINUM WIRING 15 NOT PERMITTED. ALL WIRING BY TENANT SHALL BE COPPER. TENANT SHALL INSTALL ONLY TYPE R CURRENT LIMITING FUSES. ALL FEEDER CONDUCTORS SHALL BE COPPER. INSULATION SHALL BE TYPE THHN, THIN. • ALL PANELBOARDS, LIGHTING FIXTURES, RECEPTACLES, LIGHTING SWITCHES, DISCONNECT SWITCHES AND OTHER ELECTRICAL EQUIPMENT SHALL BE U.L. APPROVED. • TENANT'S ELECTRICAL CONTRACTOR'S INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, NFPA AND ALL OTHER APPLICABLE GODES. LANDLORD'S APPROVAL OF ELECTRICAL DRAWINGS 15 NOT TO BE INTERPRETED A5 STATEMENT OF COMPLIANCE WITH CODE REQUIREMENTS. NO PVC JACKETED GABLE SHALL BE PERMITTED ABOVE HUNG CEILINGS UNLESS RUN THROUGH A CONDUIT SYSTEM. ALL EXPOSED WIRING SHALL BE IN CONDUITS. • TENANT SHALL FURNISH LANDLORD WITH TWO COPIES OF AN ELECTRICAL SUMMARY, ELECTRICAL PANELBOARD SCHEDULE, ELECTRICAL EQUIPMENT SCHEDULES AND OTHER RELATED REPORTS. • ALL WIRING SHALL BE IN EMT OR RIGID CONDUIT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED GABLE, ETC ALLOWED. • WALL SWITCHES SHALL BE 20 AMP, 120/211 VOLT RATING. USE LEVI TON SERIES 1221 THROUGH 1224 OR EQUAL SERIES BY SIERRA OR HUBBELL. • THE TENANT/TENANT'S GENERAL CONTRACTOR 15 RESPONSIBLE TO ENSURE THAT THERE ARE NO UNDERGROUND UTILITIES OR OTHER SERVICES BEFORE GUTTING ANY CONCRETE, ANYWHERE ON THE PROPERTY. THE TENANT WILL BE LIABLE FOR ALL REPAIRS AND/OR LOST BUSINESS DUE TO A UTILITY OR SERVICE INTERRUPTION A5 A RESULT OF GUTTING THE SLAB. 13•0i8 RECEIVED CITY OF TUKWILA MAY 3 0 2013 PERMIT CENTER ReQuI 11°6°1'„ TAD D Electrical Legends and Notes 5.10.13 clg NN gl 6 o'„ AS NOTED #644 Westfield South Center Seattle, WA #204 1I'J, 1,647 qk u' °„ 13064 1111'^ 1111 11:1111:13,11,111 111R11111,11111.111.1.1.:1:111, 11 ...I E.3 1 LIGHTING POWER DISTRIBUTION DEVICES GENERAL WIRING DEVICES SECURITY AND COMMUNICATION GENERAL NOTES: POWER & LIGHTING A A = FIXTURE TYPE PANELBOARD - SURFACE/FLUSH MOUNTED, 12" TO TOP -------- CONDUIT SYSTEM UNDER FLOOR T.T.Q. TELEPHONE TERMINAL BOARD - 3/4" X 4' X 81 FIRE I. FIELD VERIFY ALL CONDITIONS. 2. DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING GOND ITIONS. II / a =SWITGH LEG ix \\ STEP-DOWN TRANSFORMER TREATED PLYWOOD PAINTED WHITE �� HOMERUN. CONDUIT SYSTEM TO PANEL A5 NOTED ON TELEPHONE OUTLET LOCATION, 3/4" CONDUIT WITH O SPECIAL RECEPTACLE, 18" AFF UNLESS NOTED DRAWINGS Q PULLWIRE TO ABOVE ACCESSIBLE CEILING, GAT SE GABLE EMERGENCY SELF CONTAINED DOWN LIGHT 0 0 JUNCTION BOX OTHERWISE (UNO) TO SYSTEMS BOARD EMERGENCY BATTERY UNIT, WALL MOUNTED BATTERY e-- SIMPLEX RECEPTACLE, 18" AFF UNO TELEPHONE/DATA OUTLET LOCATION, 3/4" CONDUIT WITH [t POWERED LIGHT 41O CONDUIT UP PULLWIRE TO ABOVE ACCESSIBLE CEILING, GAT 5E GABLE DUPLEX RECEPTACLE, 20A, 5262, 18" AFF UNO � TO SYSTEMS BOARD EXIT LIGHT FIXTURE -UNIVERSAL MOUNTING •- •CONDUIT DOWN tit, FOURPLEX RECEPTACLE, 20A, 3262, 18" AFF UNO DATA OUTLET LOCATION, PROVIDE 4" 5Q. BOX, 3/4" (INDICATES DIRECTION ARROWS) RECEPTACLE WITH GROUND FAULT INTERCEPT, 18" AFF CABLING: IN = GAT5e GABLE TO SYSTEMS BOARD IN 3/4"G CEILING, GAT SE GABLE TO . CONDUIT WITH PULLWIRE TO 0 UNO I' TO 6" ABOVE CEILING, WITH INSULATED EXIT LIGHT FIXTURE - WALL MOUNTING GFI SYSTEMS BOARD valPi BUSHING. 0 WEATHERPROOF RECEPTACLE, IS AFF UNO SPEAKER (INDICATES DIRECTION ARROWS) WP "151D" 4TRACK HEAD WITH MONOPOINT CANOPY IGTO =' ISOLATED GROUND RECEPTACLE, 18" AFF UNO 15 = I CABLE TO SYSTEMS BOARD IN 3/4"G 6" ABOVE CEILING, WITH INSULATED > LOW VOLTAGE TRANSFORMER FLOOR BOX - COORDINATE LOCATION WITH FIXTURE BUSHING. AND COMPONENTS == LAYOUT KP SECURITY KEYPAD TRACK HEAD WITH TRACK SYSTEM IF NO CABLING IS NOTED, PROVIDE 3/4"C TO 6" ABOVE CEILING. PROVIDE INSULATED BUSHING � CEILING MOUNTED RECEPTACLE T B\ BUZZER AND PULL STRING. SWITCHING OJ MOTOR OR EQUIPMENT CONNECTION FIRE ALARM PUSH BUTTON $ SINGLE POLE SNITCH (WITH FOLLOWING SNITCH DESIGNATIONS) WALL MOUNTED AT 42" 0 = SWITCH LEG 3 = THREE WAY 4 = FOUR WAY M = MANUAL MOTOR STARTER WITH THERMAL OVERLOADS E = EMERGENCY PULL SWITCH K = KEY OPERATED SWITCH ril 0 CLD DISCONNECT SWITCH Ex HORN/STROBE O BELL COMBINATION MOTOR STARTER g STROBE SECURITY SYSTEM CAMERA METER TRACK CURRENT LIMITING DEVICE (LIGHTOLIER GLD OR 5D SMOKE DETECTOR, CEILING MOUNTED �+ EQUAL) TAGS SHEET IDENTIFIER OS TC NOTE: D = DIMMER SWITGH® OCCUPANCY SENSOR TIME CLOCK XX SHEET NOTE NOT ALL SYMBOLS LISTED ABOVE ARE SHOWN ON PLANS. THE SYMBOL LEGEND 15 USED FOR REFERENCE OF SYMBOLS SHOWN 014 PLANS. SEE SPECIFICATIONS FOR INFORMATION RELATED TO SYMBOLS. Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 - 1946 F. 860 • 678 • 7111 nidesign@nidesign.net © 2013 CONSULTANTS 12035 COLWICK Project Management* Design SAN ANTONIO, TX 78216 6"° G6RIPANliIRON I� ii 61�,.R u��iVtall� 5.6.13 5.1.13 5.10.13 lit„rt' �l"BB�Y iP"II�Q Ia F,HIN e II 16 �;n � i iflr ��,� ISSUED TO CLIENT FOR FINAL REVIEW ISSUED TO LANDLORD FOR FINAL REVIEW ISSUED FOR BID 8 PERMIT TENANT CRITERIA AND LANDLORD NOTES • THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO OBTAIN A COPY OF THE MALL'S TENANT CRITERIA HANDBOOK. • THE ELECTRICAL INSTALLATION MUST MEET ALL REQUIREMENTS OF THE NATIONAL ELECTRICAL GORE, LOCAL AUTHORITY HAVING JURISDICTION AND LANDLORD'S INSURANCE PROVIDER(5). • NO APPURTENANCES (INCLUDING LIGHT FIXTURES, ANTENNAS, SIGNS, ETC.) SHALL BE AFFIXED TO THE EXTERIOR WALLS OR ROOF OF LANDLORD'S BUILDING WITHOUT PRIOR APPROVAL FORM THE TENANT REVIEW COORDINATOR. • SPECIAL CARE MUST BE TAKEN TO PROTECT SHOPPING CENTER FLOORING, DOORWAYS, AND CEILINGS. ALL CARTS, DOLLIES, ETC., MUST HAVE RUBBER WHEELS. WHEELBARROWS OR OTHER WHEELED VEHICLES WITHOUT RUBBER WHEELS ARE STRICTLY PROHIBITED. ANY DAMAGE REPAIRS OR CLEANUP OF DEBRIS WHICH MUST BE HANDLED BY LANDLORD SHALL BE AT THE SOLE COST AND EXPENSE OF TENANT, PLUS A 20% ADMINISTRATIVE FEE. • LOUD NOISES WILL NOT BE TOLERATED DURING SHOPPING CENTER HOURS. • NO ONE 15 ALLOWED ON THE SHOPPING GEN i tib ROOF WITHOUT PRIOR WRITTEN APPROVAL FROM LANDLORD. • CONTRACTOR MUST RECEIVE PRIOR PERMISSION OF LANDLORD FOR WORK AFTER NORMAL WORKING HOURS. • CONTRACTOR, AND EMPLOYEES MUST PERFORM WORK IN A PROFESSIONAL MANNER. UNPROFESSIONAL BEHAVIOR, (I.E., PROFANITY, SPITTING, ETC.), WILL NOT BE TOLERATED AND WILL RESULT IN THE SHUT -DOWN OF THE JOB SITE UNTIL THE UNPROFESSIONAL GONTRAGTOR/EMPLOYEE 15 REMOVED AND NEW CONTRACTOR/EMPLOYEE 15 EMPLOYED. ALL CONSTRUCTION PERSONNEL ARE REQUIRED TO WEAR SHIRTS AND SHOES AT ALL TIMES. • LANDLORD AND LANDLORD'S AGENT RESERVES THE RIGHT TO STOP WORK IN PROGRESS FOR VIOLATIONS OF THE RULES AND REGULATIONS. • ACCESS TO LANDLORD'S SWITCHGEAR IS RESTRICTED AND MUST BE SCHEDULED WITH SHOPPING CENTER MANAGEMENT. INTERRUPTION OF POWER TO EXISTING TENANTS MUST HAVE LANDLORD'S PRIOR APPROVAL • ALL SIGN, LOGO AND SHOW WINDOW ILLUMINATION MUST BE CONTROLLED BY AN AUTOMATIC TIMEGLOGK. • NIGHT LIGHTING SHALL BE DESIGNED AND INSTALLED, RESULTING IN LOW LEVEL ILLUMINATION THROUGHOUT THE SPACE WHEN THE STORE IS CLOSED. • TENANT'S ELECTRICAL SYSTEM SHALL BE GROUNDED TO STEEL STRUCTURE PER THE NATIONAL ELECTRICAL GORE. TENANT'S CONTRACTOR SHALL REPAIR STEEL FIREPROOFING (IF APPLICABLE). • TENANT SHALL PROVIDE AND INSTALL A COMPLETE ELECTRICAL SYSTEM AND PERFORM ALL REQUIRED WORK WHICH MAY INCLUDE, BUT 15 NOT LIMITED TO, FUSED DISGONNEGT SWITCH, METER PAN AND SOCKET, METER, CONDUIT AND WIRE FROM LANDLORD'S DESIGNATED DISTRIBUTION POINT TO AND WITHIN THE PREMISES, AND ALL WIRING AND CONNECTIONS FROM THE CENTRAL DISTRIBUTION PANELS, LIGHTING PANELS, ALL FEEDER CONDUCTORS, ANY REQUIRED TRANSFORMERS, ALL CONDUIT AND WIRING FOR POWER DISTRIBUTION WITHIN THE LEASED PREMISES, LIGHTING FIXTURES, RECEPTACLES, SWITCHES AND MISCELLANEOUS DEVICES REQUIRED WITHIN THE PREMISES. • ALL ELECTRICAL WORK WILL CONFORM TO BUILDING DESIGN PARAMETERS AND ALL APPLICABLE GOVERNMENTAL REGULATIONS INCLUDING ENERGY CONSERVATION GODES. WHERE PREVIOUSLY EXISTING ELECTRICAL COMPONENTS ARE TO BE REUSED, TENANT ACCEPTS ALL EXISTING ELECTRICAL COMPONENTS IN AN "A5 -IS CONDITION AND WILL REPLACE, REPAIR OR REFURBISH THESE COMPONENTS TO A "LIKE -NEW” CONDITION ADEQUATE FOR THE OCCUPANCY OF THE PREMISES AND COMPLIANT WITH BUILDING DESIGN PARAMETERS AND ALL GOVERNMENTAL REGULATIONS. • ALL MODIFICATIONS TO THE EXISTING SYSTEM WITHIN THE DEMISED PREMISES SHALL BE BY TENANT'S CONTRACTOR. TENANT'S CONTRACTOR AGGEPTS EXISTING SYSTEM IN "AS -IS" CONDITION AND 15 RESPONSIBLE FOR DETERMINING THE ADEQUACY OF ANY EQUIPMENT OR SYSTEM WHICH TENANT'S CONTRACTOR GH005E5 TO REUSE. ANY EQUIPMENT OR SYSTEM COMPONENTS WHICH TENANT'S CONTRACTOR INTENDS TO USE OR REUSE SHALL BE CLEARLY DESIGNATED AS SUCH ON TENANT'S DRAWINGS. • INSTALLATION SHALL CONFORM TO THE FOLLOWING: A. ELEGTRIGAL PANELS SHALL HAVE COPPER BUS BARS AND BOLT -IN BREAKERS. LOAD CENTERS ARE NOT PERMITTED. THE NATIONAL ELECTRICAL CODE REQUIRES THAT LIGHTING PANELS CONTAIN CIRGUIT BREAKERS RATED FOR SWITCHING DUTY. B. PANEL BOARDS SHALL BE DESIGNED FOR A MINIMUM OF 25% EXCESS CAPACITY BASED ON CONNECTED LOAD. TENANT SHALL PROVIDE 20% SPARE BREAKER SPACE. • ENGRAVED, MECHANICALLY ATTACHED NAME PLATES SHALL BE INSTALLED ON EACH PANELBOARD, TRANSFORMER, DISGONNEGT SWITCH, MOTOR STARTER, ETC. • A CONVENIENCE RECEPTACLE AND SWITCHED LIGHT FIXTURE SHALL BE INSTALLED ADJACENT TO ALL ROOF MOUNTED MEGHANIGAL EQUIPMENT. • TENANT SHALL PROVIDE CONDUIT AND WIRING FOR THE PROVISION OF TELEPHONE AND GABLE (IF AVAILABLE) SERVICE TO THE LEASED PREMISES FROM THE LANDLORD'S DESIGNATED TELEPHONE UTILITY DISTRIBUTION PANEL TO AND WITHIN THE PREMISES. TENANT SHALL FURNISH AND INSTALL ALL TELEPHONE AND GABLE EQUIPMENT, CONDUIT AND WIRING, OUTLET BOXES AND DEVICES WITHIN THE LEASED PREMISES. TENANT SHALL MAKE ALL NECESSARY ARRANGEMENTS DIRECTLY WITH THE APPROPRIATE TELEPHONE AND GABLE SERVICE PROVIDER(S). ALL TELEPHONE WIRE AND GABLE OUTSIDE OF THE LEASED PREMISES SHALL BE ROUTED THROUGH CONDUIT FROM THE APPLICABLE UTILITY DISTRIBUTION POINT TO AND WITHIN THE PREMISES BY THE TENANT. ALL TELEPHONE AND GABLE WIRING IN THE PREMISES SHALL BE PLENUM RATED. • ALUMINUM WIRING 15 NOT PERMITTED. ALL WIRING BY TENANT SHALL BE COPPER. TENANT SHALL INSTALL ONLY TYPE R CURRENT LIMITING FUSES. ALL FEEDER CONDUCTORS SHALL BE COPPER. INSULATION SHALL BE TYPE THHN, THIN. • ALL PANELBOARDS, LIGHTING FIXTURES, RECEPTACLES, LIGHTING SWITCHES, DISCONNECT SWITCHES AND OTHER ELECTRICAL EQUIPMENT SHALL BE U.L. APPROVED. • TENANT'S ELECTRICAL CONTRACTOR'S INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, NFPA AND ALL OTHER APPLICABLE GODES. LANDLORD'S APPROVAL OF ELECTRICAL DRAWINGS 15 NOT TO BE INTERPRETED A5 STATEMENT OF COMPLIANCE WITH CODE REQUIREMENTS. NO PVC JACKETED GABLE SHALL BE PERMITTED ABOVE HUNG CEILINGS UNLESS RUN THROUGH A CONDUIT SYSTEM. ALL EXPOSED WIRING SHALL BE IN CONDUITS. • TENANT SHALL FURNISH LANDLORD WITH TWO COPIES OF AN ELECTRICAL SUMMARY, ELECTRICAL PANELBOARD SCHEDULE, ELECTRICAL EQUIPMENT SCHEDULES AND OTHER RELATED REPORTS. • ALL WIRING SHALL BE IN EMT OR RIGID CONDUIT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED GABLE, ETC ALLOWED. • WALL SWITCHES SHALL BE 20 AMP, 120/211 VOLT RATING. USE LEVI TON SERIES 1221 THROUGH 1224 OR EQUAL SERIES BY SIERRA OR HUBBELL. • THE TENANT/TENANT'S GENERAL CONTRACTOR 15 RESPONSIBLE TO ENSURE THAT THERE ARE NO UNDERGROUND UTILITIES OR OTHER SERVICES BEFORE GUTTING ANY CONCRETE, ANYWHERE ON THE PROPERTY. THE TENANT WILL BE LIABLE FOR ALL REPAIRS AND/OR LOST BUSINESS DUE TO A UTILITY OR SERVICE INTERRUPTION A5 A RESULT OF GUTTING THE SLAB. 13•0i8 RECEIVED CITY OF TUKWILA MAY 3 0 2013 PERMIT CENTER ReQuI 11°6°1'„ TAD D Electrical Legends and Notes 5.10.13 clg NN gl 6 o'„ AS NOTED #644 Westfield South Center Seattle, WA #204 1I'J, 1,647 qk u' °„ 13064 1111'^ 1111 11:1111:13,11,111 111R11111,11111.111.1.1.:1:111, 11 ...I E.3 1 GENERAL NOTES: POWER & LIGHTING 15. ALL 20A BRANCH GIRGUITS BETWEEN 100' AND 150' IN LENGTH, #10 AWG WIRE SHALL BE USED. FOR ALL 20A BRANCH GIRGUITS OVER ISO' IN LENGTH, *8 AWG WIRE SHALL BE USED. 16. ALL 20A BRANCH GIRGUITS LESS THAN 100' IN LENGTH, SHALL BE #12 CONDUCTORS, #12 CND., 3/4" UNLESS NOTED OTHERWISE. 11. CIRGUITING INDICATED ON PLAN 15 PARTIALLY DIAGRAMMATIC FOR CLARITY. CIRCUITING SHALL BE "THRU-WIRING" WHERE/WHEN POSSIBLE. MULTI -CONNECTIONS TO A SINGLE LIGHT FIXTURE FOR FIELD CONDITIONS OR VOLTAGE DROP FACTORS MAY BE REQUIRED (FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU-WIRING"), AND RELATED COSTS SHALL BE INCLUDED IN ELECTRICAL CONTRACTORS BID. 18. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT QUANTITY AND LOCATION OF LIGHT FIXTURES. ISI. EMERGENCY LIGHTS SHALL BE INSTALLED AND GIRGUITED PER N.E.G. AND ALL LOCAL GORES. ALL EMERGENCY FIXTURES SHALL BE DUAL VOLTAGE (120/211 AUTO XFMR) BATTERY BACK-UP UNITS. INSTALL CENTRAL BATTERY BACK-UP ONLY IF INDIVIDUAL UNITS ARE PROHIBITED BY LOCAL GODES, CLOSELY COORDINATE WITH TENANT CONSTRUCTION MANAGER. 20. ELECTRICAL GONTRAGTOR SHALL MAKE ALL FINAL ELECTRICAL CONNECTIONS AS REQUIRED FOR A COMPLETE AND OPERATING SYSTEM. 21. WHERE DRYWALL GEILINGS ARE USED, ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITING 50 THAT JUNCTION BOXES ACCESS PANELS ARE NOT REQUIRED IN THESE DRYWALL CEILING AREAS. (THE USE OF JUNCTION BOXES IN THESE DRYWALL CEILINGS 15 NOT PERMITTED, ARRANGE CIRCUITS TO AVOID THIS SITUATION). FIELD COORDINATE WITH TENANTS CONSTRUCTION MANAGER PRIOR TO ROUGH -IN TO AVOID CONFLICTS. JUNCTION BOXES MAY BE PLACED ABOVE LAY -IN CEILINGS. 22. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MEGHANIGAL CONTRACTOR, PRIOR TO ORDERING RELATED ELECTRICAL EQUIPMENT. 23. PLACEMENT OF ALL RECEPTACLES SHALL BE INTENTIONAL (I .E. CENTERED ON COLUMNS OR WALL FEATURES, OR TIGHT TO CORNER). IF RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANT'S CONSTRUCTION MANAGER PRIOR TO RECEPTACLE BOX ROUGH -IN. 24. INSTALLATION OF LIGHTING FIXTURES SHALL BE ACCORDING TO MANUFACTURER'S RECOMMENDATIONS AND ACCORDING TO CODE REQUIREMENTS. 25. ALL FIXTURES SCHEDULED MAY NOT NECESSARILY BE USED ON THIS PROJECT. REFER TO LI GHTI NG PLAN. 26. PROVIDE ALL NECESSARY COMPONENTS TO MAKE A COMPLETE WORKING SYSTEM. VERIFY ROW LENGTHS, FEED POINT AND MOUNTING REQUIREMENTS PRIOR TO ORDERING. 21. TAKE ADEQUATE CARE TO CORRECTLY LOCATE ALL ELECTRICAL STUBOUTS, FLOOR BOXES, .1 -BOXES, TRACK, ETG. PRECISE LOCATIONS OF FLOOR OUTLETS AND J -BOXES 15 VERY IMPORTANT. ALL GAT -5 WIRE TO BE PROVIDED BY OWNER'S VENDOR. I. FIELD VERIFY ALL CONDITIONS. 2. DESIGN DRAWINGS ARE SCHEMATIC. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING OR AWARD OF CONTRACT TO INSPECT EXISTING FIELD CONDITIONS. THIS CONTRACT SHALL INCLUDE ALL LABOR AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING GOND ITIONS. 3. THE CONTRACTOR SHALL CONTACT THE OWNER PRIOR TO BIDDING FOR IN I L PRETATIONS AND CLARIFICATIONS OF THE DESIGN AND INCLUDE IN 1415 BID ALL COSTS TO MEET THE DESIGN INTENT. CLARIFICATIONS MADE BY THE ARCHITECT, ENGINEER OR OWNER AFTER BIDDING WILL BE FINAL AND SHALL BE IMPLEMENTED AT CONTRACTORS COST. 4. BIDDING CONTRACTORS SHALL HAVE A WORKING KNOWLEDGE OF LOCAL CODES AND ORDINANCES AND SHALL INCLUDE IN THEIR BIDS THE COSTS FOR ALL WORK INSTALLED IN STRICT ACCORDANCE WITH GOVERNING CODES, THE PLANS AND SPECIFICATIONS NOT WITHSTANDING. THE CONTRACTOR SHALL ALERT ARCHITECT, ENGINEER OR. OWNER OF ANY APPARENT DISGREPANGIES BETWEEN GOVERNING GORES AND DESIGN INTENT. S. MINOR VARIATIONS DUE TO UNFORESEEN CONDITIONS THAT MAY EFFECT THE CONTRACTOR'S SCOPE OF WORK, REQUIRED FOR ACCOMPLISHING THE INTENT OF THIS DESIGN SHALL BE INCLUDED 1N CONTRACTOR'S PRIDING. 6. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL REQUIRED PERMITS. CONTRACTOR'S INSTALLATION SHALL CONFORM TO ALL LOCAL CODE REQUIREMENTS. 1. ELECTRICAL CONTRACTOR SHALL VERIFY EXACT PLACEMENT OF ALL DEVICES SHOWN OF THE ELECTRICAL CONSTRUCTION DOCUMENTS WITH ARCHITECTURAL, MEGHANIGAL AND PLUMBING DRAWINGS PRIOR TO FINAL PLACEMENT. 8. CONTRACTOR SHALL BECOME FAMILIAR WITH REQUIRED DEMOLITION WORK PRIOR TO BIDDING AND START OF WORK. CONTRACTOR SHALL BE RESPONSIBLE TO PROVIDE ALL DEMOLITION AS REQUIRED FOR INSTALLATION OF NEV WORK. q. CONTRACTOR SHALL COORDINATE INSTALLATION OF ELECTRICAL WORK ABOVE THE CEILING TO PROVIDE THE GREATEST POSSIBLE CLEARANCE FOR INSTALLATION OF PLUMBING AND MEGHANIGAL INSTALLATION. CONDUIT RUNS TO BE RUN THROUGH TRUSSES WHERE POSSIBLE. ORDINATE EXACT LOCATION OF DEVICES SERVING CASEWORK WITH CASEWORK 10. COE GOORDINAT R. II. COORDINATE ALL LOW VOLTAGE CONDUIT AND ROUGH -IN REQUIREMENTS WITH LOW VOLTAGE CONTRACTORS. 12. SWITCHBOARDS, PANELBOARDS, DISCONNECT SWITCHES, TRANSFORMER AND CONTACTORS SHALL BE "LISTED" AND "IDENTIFIED" AS RATED FOR A MINIMUM.OF 15I6C CONDUCTOR TERMINATION. 13. ELECTRICAL CONTRACTOR SHALL INCLUDE EQUIPMENT GROUND CONDUCTOR IN ALL RACEWAYS. SIZE RACEWAYS AS NECESSARY TO COMPLY WITH N.E.G. 14. ALL EMPTY CONDUITS SHALL BE PROVIDED WITH A PULL WIRE. Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 - 1946 F. 860 • 678 • 7111 nidesign@nidesign.net © 2013 CONSULTANTS 12035 COLWICK Project Management* Design SAN ANTONIO, TX 78216 6"° G6RIPANliIRON I� ii 61�,.R u��iVtall� 5.6.13 5.1.13 5.10.13 lit„rt' �l"BB�Y iP"II�Q Ia F,HIN e II 16 �;n � i iflr ��,� ISSUED TO CLIENT FOR FINAL REVIEW ISSUED TO LANDLORD FOR FINAL REVIEW ISSUED FOR BID 8 PERMIT TENANT CRITERIA AND LANDLORD NOTES • THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO OBTAIN A COPY OF THE MALL'S TENANT CRITERIA HANDBOOK. • THE ELECTRICAL INSTALLATION MUST MEET ALL REQUIREMENTS OF THE NATIONAL ELECTRICAL GORE, LOCAL AUTHORITY HAVING JURISDICTION AND LANDLORD'S INSURANCE PROVIDER(5). • NO APPURTENANCES (INCLUDING LIGHT FIXTURES, ANTENNAS, SIGNS, ETC.) SHALL BE AFFIXED TO THE EXTERIOR WALLS OR ROOF OF LANDLORD'S BUILDING WITHOUT PRIOR APPROVAL FORM THE TENANT REVIEW COORDINATOR. • SPECIAL CARE MUST BE TAKEN TO PROTECT SHOPPING CENTER FLOORING, DOORWAYS, AND CEILINGS. ALL CARTS, DOLLIES, ETC., MUST HAVE RUBBER WHEELS. WHEELBARROWS OR OTHER WHEELED VEHICLES WITHOUT RUBBER WHEELS ARE STRICTLY PROHIBITED. ANY DAMAGE REPAIRS OR CLEANUP OF DEBRIS WHICH MUST BE HANDLED BY LANDLORD SHALL BE AT THE SOLE COST AND EXPENSE OF TENANT, PLUS A 20% ADMINISTRATIVE FEE. • LOUD NOISES WILL NOT BE TOLERATED DURING SHOPPING CENTER HOURS. • NO ONE 15 ALLOWED ON THE SHOPPING GEN i tib ROOF WITHOUT PRIOR WRITTEN APPROVAL FROM LANDLORD. • CONTRACTOR MUST RECEIVE PRIOR PERMISSION OF LANDLORD FOR WORK AFTER NORMAL WORKING HOURS. • CONTRACTOR, AND EMPLOYEES MUST PERFORM WORK IN A PROFESSIONAL MANNER. UNPROFESSIONAL BEHAVIOR, (I.E., PROFANITY, SPITTING, ETC.), WILL NOT BE TOLERATED AND WILL RESULT IN THE SHUT -DOWN OF THE JOB SITE UNTIL THE UNPROFESSIONAL GONTRAGTOR/EMPLOYEE 15 REMOVED AND NEW CONTRACTOR/EMPLOYEE 15 EMPLOYED. ALL CONSTRUCTION PERSONNEL ARE REQUIRED TO WEAR SHIRTS AND SHOES AT ALL TIMES. • LANDLORD AND LANDLORD'S AGENT RESERVES THE RIGHT TO STOP WORK IN PROGRESS FOR VIOLATIONS OF THE RULES AND REGULATIONS. • ACCESS TO LANDLORD'S SWITCHGEAR IS RESTRICTED AND MUST BE SCHEDULED WITH SHOPPING CENTER MANAGEMENT. INTERRUPTION OF POWER TO EXISTING TENANTS MUST HAVE LANDLORD'S PRIOR APPROVAL • ALL SIGN, LOGO AND SHOW WINDOW ILLUMINATION MUST BE CONTROLLED BY AN AUTOMATIC TIMEGLOGK. • NIGHT LIGHTING SHALL BE DESIGNED AND INSTALLED, RESULTING IN LOW LEVEL ILLUMINATION THROUGHOUT THE SPACE WHEN THE STORE IS CLOSED. • TENANT'S ELECTRICAL SYSTEM SHALL BE GROUNDED TO STEEL STRUCTURE PER THE NATIONAL ELECTRICAL GORE. TENANT'S CONTRACTOR SHALL REPAIR STEEL FIREPROOFING (IF APPLICABLE). • TENANT SHALL PROVIDE AND INSTALL A COMPLETE ELECTRICAL SYSTEM AND PERFORM ALL REQUIRED WORK WHICH MAY INCLUDE, BUT 15 NOT LIMITED TO, FUSED DISGONNEGT SWITCH, METER PAN AND SOCKET, METER, CONDUIT AND WIRE FROM LANDLORD'S DESIGNATED DISTRIBUTION POINT TO AND WITHIN THE PREMISES, AND ALL WIRING AND CONNECTIONS FROM THE CENTRAL DISTRIBUTION PANELS, LIGHTING PANELS, ALL FEEDER CONDUCTORS, ANY REQUIRED TRANSFORMERS, ALL CONDUIT AND WIRING FOR POWER DISTRIBUTION WITHIN THE LEASED PREMISES, LIGHTING FIXTURES, RECEPTACLES, SWITCHES AND MISCELLANEOUS DEVICES REQUIRED WITHIN THE PREMISES. • ALL ELECTRICAL WORK WILL CONFORM TO BUILDING DESIGN PARAMETERS AND ALL APPLICABLE GOVERNMENTAL REGULATIONS INCLUDING ENERGY CONSERVATION GODES. WHERE PREVIOUSLY EXISTING ELECTRICAL COMPONENTS ARE TO BE REUSED, TENANT ACCEPTS ALL EXISTING ELECTRICAL COMPONENTS IN AN "A5 -IS CONDITION AND WILL REPLACE, REPAIR OR REFURBISH THESE COMPONENTS TO A "LIKE -NEW” CONDITION ADEQUATE FOR THE OCCUPANCY OF THE PREMISES AND COMPLIANT WITH BUILDING DESIGN PARAMETERS AND ALL GOVERNMENTAL REGULATIONS. • ALL MODIFICATIONS TO THE EXISTING SYSTEM WITHIN THE DEMISED PREMISES SHALL BE BY TENANT'S CONTRACTOR. TENANT'S CONTRACTOR AGGEPTS EXISTING SYSTEM IN "AS -IS" CONDITION AND 15 RESPONSIBLE FOR DETERMINING THE ADEQUACY OF ANY EQUIPMENT OR SYSTEM WHICH TENANT'S CONTRACTOR GH005E5 TO REUSE. ANY EQUIPMENT OR SYSTEM COMPONENTS WHICH TENANT'S CONTRACTOR INTENDS TO USE OR REUSE SHALL BE CLEARLY DESIGNATED AS SUCH ON TENANT'S DRAWINGS. • INSTALLATION SHALL CONFORM TO THE FOLLOWING: A. ELEGTRIGAL PANELS SHALL HAVE COPPER BUS BARS AND BOLT -IN BREAKERS. LOAD CENTERS ARE NOT PERMITTED. THE NATIONAL ELECTRICAL CODE REQUIRES THAT LIGHTING PANELS CONTAIN CIRGUIT BREAKERS RATED FOR SWITCHING DUTY. B. PANEL BOARDS SHALL BE DESIGNED FOR A MINIMUM OF 25% EXCESS CAPACITY BASED ON CONNECTED LOAD. TENANT SHALL PROVIDE 20% SPARE BREAKER SPACE. • ENGRAVED, MECHANICALLY ATTACHED NAME PLATES SHALL BE INSTALLED ON EACH PANELBOARD, TRANSFORMER, DISGONNEGT SWITCH, MOTOR STARTER, ETC. • A CONVENIENCE RECEPTACLE AND SWITCHED LIGHT FIXTURE SHALL BE INSTALLED ADJACENT TO ALL ROOF MOUNTED MEGHANIGAL EQUIPMENT. • TENANT SHALL PROVIDE CONDUIT AND WIRING FOR THE PROVISION OF TELEPHONE AND GABLE (IF AVAILABLE) SERVICE TO THE LEASED PREMISES FROM THE LANDLORD'S DESIGNATED TELEPHONE UTILITY DISTRIBUTION PANEL TO AND WITHIN THE PREMISES. TENANT SHALL FURNISH AND INSTALL ALL TELEPHONE AND GABLE EQUIPMENT, CONDUIT AND WIRING, OUTLET BOXES AND DEVICES WITHIN THE LEASED PREMISES. TENANT SHALL MAKE ALL NECESSARY ARRANGEMENTS DIRECTLY WITH THE APPROPRIATE TELEPHONE AND GABLE SERVICE PROVIDER(S). ALL TELEPHONE WIRE AND GABLE OUTSIDE OF THE LEASED PREMISES SHALL BE ROUTED THROUGH CONDUIT FROM THE APPLICABLE UTILITY DISTRIBUTION POINT TO AND WITHIN THE PREMISES BY THE TENANT. ALL TELEPHONE AND GABLE WIRING IN THE PREMISES SHALL BE PLENUM RATED. • ALUMINUM WIRING 15 NOT PERMITTED. ALL WIRING BY TENANT SHALL BE COPPER. TENANT SHALL INSTALL ONLY TYPE R CURRENT LIMITING FUSES. ALL FEEDER CONDUCTORS SHALL BE COPPER. INSULATION SHALL BE TYPE THHN, THIN. • ALL PANELBOARDS, LIGHTING FIXTURES, RECEPTACLES, LIGHTING SWITCHES, DISCONNECT SWITCHES AND OTHER ELECTRICAL EQUIPMENT SHALL BE U.L. APPROVED. • TENANT'S ELECTRICAL CONTRACTOR'S INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE, NFPA AND ALL OTHER APPLICABLE GODES. LANDLORD'S APPROVAL OF ELECTRICAL DRAWINGS 15 NOT TO BE INTERPRETED A5 STATEMENT OF COMPLIANCE WITH CODE REQUIREMENTS. NO PVC JACKETED GABLE SHALL BE PERMITTED ABOVE HUNG CEILINGS UNLESS RUN THROUGH A CONDUIT SYSTEM. ALL EXPOSED WIRING SHALL BE IN CONDUITS. • TENANT SHALL FURNISH LANDLORD WITH TWO COPIES OF AN ELECTRICAL SUMMARY, ELECTRICAL PANELBOARD SCHEDULE, ELECTRICAL EQUIPMENT SCHEDULES AND OTHER RELATED REPORTS. • ALL WIRING SHALL BE IN EMT OR RIGID CONDUIT. FLEXIBLE CONDUIT MAY ONLY BE USED FOR FINAL CONNECTIONS FROM OUTLET BOXES TO LIGHT FIXTURES, MOTORS, APPLIANCES, ETC, MAX LENGTH 6 FEET. NO BX, ROMEX, ARMORED GABLE, ETC ALLOWED. • WALL SWITCHES SHALL BE 20 AMP, 120/211 VOLT RATING. USE LEVI TON SERIES 1221 THROUGH 1224 OR EQUAL SERIES BY SIERRA OR HUBBELL. • THE TENANT/TENANT'S GENERAL CONTRACTOR 15 RESPONSIBLE TO ENSURE THAT THERE ARE NO UNDERGROUND UTILITIES OR OTHER SERVICES BEFORE GUTTING ANY CONCRETE, ANYWHERE ON THE PROPERTY. THE TENANT WILL BE LIABLE FOR ALL REPAIRS AND/OR LOST BUSINESS DUE TO A UTILITY OR SERVICE INTERRUPTION A5 A RESULT OF GUTTING THE SLAB. 13•0i8 RECEIVED CITY OF TUKWILA MAY 3 0 2013 PERMIT CENTER ReQuI 11°6°1'„ TAD D Electrical Legends and Notes 5.10.13 clg NN gl 6 o'„ AS NOTED #644 Westfield South Center Seattle, WA #204 1I'J, 1,647 qk u' °„ 13064 1111'^ 1111 11:1111:13,11,111 111R11111,11111.111.1.1.:1:111, 11 ...I E.3 1 DIVISION 16: ELECTRICAL SPECIFICATIONS I6AI GENERAL INSTRUCTIONS ISA I-1 GENERAL REQUIREMENTS. ALL REQUIREMENTS UNDER DIVISION ONE AND THE GENERAL AND SUPPLEMENTARY CONDITIONS OF THESE SPECIFICATIONS SHALL BEA PART OF T14I5 SECTION. EACH CONTRACTOR SHALL BE RESPONSIBLE TO BECOME THOROUGHLY FAMILIAR'WITH ALL ITS CONTENTS AS TO REQUIREMENTS WHICH AFFECT THIS DIVISION OR SECTION. THE WORK REQUIRED UNDER THIS SECTION INCLUDES ALL MATERIAL, EQUIPMENT, APPLIANCES, AND LABOR REQUIRED TO COMPLETE THE ENTIRE SYSTEM A5 REQUIRED BY THE DRAWINGS AND; SPECIFICATIONS, OR REASONABLY INFERRED TO BE NECESSARY TO FACILITATE EACH SYSTEMS FUNCTIONING AS INDICATED BY THE DESIGN AND THE EQUIPMENT SPECIFIED. 16A 1-2 DEFINITIONS. FURNISH= THE TERM "FURNISH" 15 USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SIGN, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION AND SIMILAR OPERATIONS." INSTALL: THE TERM "INSTALL" 15 USED TO DESCRIBE OPERATIONS AT THE PROJECT SITE INCLUDING THE ACTUAL 'UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING, WORKING TO DIMENSION, FINISHING, DURING, PROTEGTING, GLEANING, AND SIMILAR OPERATIONS." PROVIDE: TFE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR. INTENDED USE." FURNISHED BY OWNER OR FURNISHED BY OTHERS: THE ITEM WILL BE FURNISHED BY THE OWNER OR OTHERS. IT 15 TO BE INSTALLED AND CONNECTED UNDER THE REQUIREMENTS OF TH15 DIVISION, COMPLETE AND READY FOR OPERATION, INCLUDING ITEMS INCIDENTAL TO THE WORK, INCLUDING SERVICES NECESSARY FOR PROPER INSTALLATION AND OPERATION. THE INSTALLATION SHALL BE INCLUDED UNDER THE GUARANTEE: REQUIRED BY THIS DIVISION. ENGINEER: WHERE REFERENCED IN THIS DIVISION, "ENGINEER" 15 THE ENGINEER OF RECORD AND THE DESIGN PROFESSIONAL FOR THE WORK UNDER T14I5 DIVISION, AND 15 A CONSULTANT TO, AND AND AUTHORIZED REPRESENTATIVE OF, THE ARCHITECT, AS DEFINED IN THE GENERAL AND/OR SUPPLEMENTARY CONDITIONS. WHEN USED IN THIS DIVISION, IT MEANS INCREASED INVOLVEMENT BY, AND OBLIGATIONS TO, THE ENGINEER, IN ADDITION TO THE INVOLVEMENT BY, AND OBLIGATIONS TO, THE "ARCHITECT". AHJ: THE LOCAL CODE AND/OR INSPECTION AGENCY (AUTHORITY) HAVING JURISDICTION OVER THE WORK. THE TERMS "APPROVED EQUAL", "EQUIVALENT", OR "EQUAL" ARE USED SYNONYMOUSLY AND SHALL MEAN "ACCEPTED BY OR ACCEPTABLE TO THE ENGINEER AS EQUIVALENT TO THE ITEM OR MANUFACTURER SPECIFIED". THE TERM "APPROVED" SHALL MEAN LABELED, LISTED, OR BOTH, BY A NATIONALLY RECOGNIZED TESTING LABORATORY (E.G. UL, ETL, GSA), AND ACCEPTABLE TO THE AHJ OVER THIS PROJECT. 16A 1-3 INSPECTION OF SITE. THE CONTRACTOR SHALL PERSONALLY INSPECT THE SITE OF THE PROPOSED WORK AND BECOME FULLY INFORMED AS TO THE CONDITIONS UNDER WHICH THE WORK 15 TO BE DONE. FAILURE TO DO 50 WILL NOT BE CONSIDERED SUFFICIENT JUSTIFICATION TO REQUEST OR OBTAIN EXTRA COMPENSATION OVER AND ABOVE THE CONTRACT PRICE. ISA 1-4 MATERIAL AND WORKMANSHIP. ALL MATERIAL AND APPARATUS SHALL BE NEW AND IN FIRST GLASS CONDITION. ALL MATERIAL AND APPARATUS SHALL HAVE MARKINGS OR A NAMEPLATE IDENTIFYING THE MANUFACTURER AND PROVIDING SUFFICIENT REFERENCE TO ESTABLISH QUALITY, SIZE AND CAPACITY. ALL WORKMANSHIP SHALL BE OF THE FINEST POSSIBLE BY EXPERIENCED MECHANICS OF THE PROPER TRADE. IN GENERAL, ALL MATERIALS AND EQUIPMENT SHALL BE OF COMMERCIAL SPECIFICATION GRADE IN QUALITY. LIGHT DUTY AND RESIDENTIAL TYPE EQUIPMENT WILL NOT BE AGGEPTABLE. ALL HOISTS, SCAFFOLDS, STAGING, RUNWAYS, TOOLS, MACHINERY AND EQUIPMENT REQUIRED FOR THE PERFORMANCE OF THE ELECTRICAL WORK SHALL BE FURNISHED BY THI5 CONTRACTOR. MATERIAL AND EQUIPMENT SHALL BE STORED AND MAINTAINED IN CLEAN CONDITION, AND PROTECTED FROM WEATHER, MOISTURE, AND PHYSICAL DAMAGE. )6A 1-5 COORDINATION. THE CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER CONTRACTORS AND SUBCONTRACTORS 50 THAT VARIOUS COMPONENTS OF THE ELECTRICAL SYSTEMS WILL BE INSTALLED AT THE PROPER TIME, WILL FIT THE AVAILABLE SPACE, AND WILL ALLOW PROPER SERVICE ACCESS TO ALL EQUIPMENT. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL, STRUCTURAL AND MECHANICAL DRAWINGS AND TO RELEVANT EQUIPMENT DRAWINGS TO DETERMINE THE EXTENT OF CLEAR SPACES. THE CONTRACTOR SHALL MAKE ALL OFFSETS REQUIRED TO CLEAR EQUIPMENT, BEAMS AND OTHER STRUCTURAL MEMBERS, AND TO FACILITATE CONGEALING CONDUIT IN THE MANNER ANTICIPATED IN THE DESIGN. THE CONTRACTOR SHALL PROVIDE MATERIALS WITH TRIM WHICH WILL FIT PROPERLY THE TYPES OF CEILING, WALL, OR FLOOR FINISHES ACTUALLY INSTALLED ISA 1-6 DIMENSIONS AND LAYOUTS. THE DRAWINGS ARE SCHEMATIC IN NATURE, BUT SHOW THE VARIOUS COMPONENTS OF THE SYSTEMS APPROXIMATELY TO SCALE AND ATTEMPT TO INDICATE HOW THEY ARE TO BE INTEGRATED WITH OTHER PARTS OF THE BUILDING. FIGURED DIMENSIONS SHALL BE TAKEN IN PREFERENCE TO SCALE DIMENSIONS. DETERMINE EXACT LOCATIONS BY JOB MEASUREMENTS, BY CHECKING THE REQUIREMENTS OF O1HER TRADES, AND BY REVIEWING ALL CONTRACT DOCUMENTS. THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ERRORS WHICH COULD HAVE BEEN AVOIDED BY PROPER CHECKING AND INSPECTION. J6A 1-7 ORDINANCES AND CODES. CONTRACTORS PERFORMANCE, WORKMANSHIP AND MATERIALS SHALL COMPLY WITH NATIONAL FIRE PROTECTION ASSOCIATION CODES, STATE AND LOCAL BUILDING CODES, AND/OR ALL OTHER APPLICABLE CODES AND ORDINANCES. CONTRACTOR SHALL COMPLY WITH RULES AND REGULATIONS OF PUBLIC UTILITIES AND MUNICIPAL DEPARTMENTS AFFECTED BY CONNECTION OF SERVICES. OBTAIN AND PAY FOR ALL PERMITS. CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ANY VIOLATION OF THE LAW. CONTRACTOR SHALL MAINTAIN ALL NECESSARY SIGNAL LIGHTS AND GUARDS FOR THE SAFETY OF THE PUBLIC. I6A 1-S SUBSTITUTIONS. THIS SPECIFICATION PROVIDES THAT THE BASE BID OF ALL CONTRACTORS SHALL INCLUDE THE PRODUCTS SPECIFICALLY NAMED, THE CONTRAGTOR BEING PERMITTED TO SUBMIT IN THE FORM OF ALTERNATES, WITH HI5 PROPOSAL, PRODUCTS OF ANY OTHER MANUFACTURERS FOR SIMILAR USE, PROVIDED THE DITTLRLNGE IN COST, IF ANY, 15 SPECIFIED IN EACH CASE. THE TERMS "APPROVED", "APPROVED EQUAL", OR "EQUAL" SHALL MEAN APPROVED BY THE ENGINEER A5 AN ACCEPTABLE ALTERNATE BID. NO SUBSTITUTIONS WILL BE CONSIDERED THAT ARE NOT BID AS AN ALTERNATE. )6A 1-4 SHOP DRAWINGS. SUBMIT FOR APPROVAL TWO SETS OF MANUFACTURERS SHOP DRAWINGS OF ALL MAJOR ITEMS OF EQUIPMENT AND ALL ITEMS REQUIRING COORDINATION BETWEEN CONTRACTORS. BEFORE SUBMITTING SHOP DRAWINGS AND MATERIAL LISTS, THE CONTRACTOR SHALL VERIFY THAT ALL EQUIPMENT SUBMITTED 15 MUTUALLY COMPATIBLE AND SUITABLE FOR THE INTENDED USE, AND SHALL FIT THE AVAILABLE SPACE AND ALLOW AMPLE ROOM FOR MAINTENANCE. THE ENGINEER'S CHECKING AND SUBSEQUENT APPROVAL OF SUCH SHOP DRAWINGS SHALL NOT RELIEVE THE CONTRACTOR FROM RESPONSIBILITY FOR ERRORS IN DIMENSIONS, DETAILS, SIZE OF MEMBERS, OR QUANTITIES; OR OMISSIONS OF COMPONENTS OR FITTINGS; OR FOR COORDINATING ITEMS WITH ACTUAL BUILDING CONDITIONS. J6A 1-10 ADJUSTING. ALIGNING AND TESTING. ALL ELECTRICAL EQUIPMENT ON THIS PROJECT FURNISHED UNDER THI5 DIVISION AND ALL ELECTRICAL EQUIPMENT FURNISHED BY OTHERS SHALL BE ADJUSTED, ALIGNED AND TESTED FOR PROPER OPERATION BY THE ELECTRICAL CONTRACTOR. COMPLETE WIRING SYSTEMS SHALL BE FREE FROM SHORT CIRCUITS. ALL MOTORS SHALL BE VERIFIED FOR PROPER ROTATION. THE CONTRACTOR SHALL MAINTAIN ON THE PROJECT PREMISES THE FOLLOWING AT ALL TIMES: A TRUE RMS READING VOLTMETER, A TRUE RMS READING AMMETER, AND A MEGGER INSULATION RESISTANCE TESTER. THE CONTRACTOR SHALL PROVIDE TEST DATA READINGS AS REQUESTED OR A5 REQUIRED. 16A I-11 OPERATION ANp MAINTENANCE INSTRUCTIONS. SUBMIT TO THE OWNER (2) COPIES, (I) LEFT AT STORE, (I) SUBMITTED TO YGG PROJECT MANAGER, EACH OF MATERIAL FOR MAINTENANCE AND OPERATION INSTRUCTION MANUALS, APPROPRIATELY BOUND INTO MANUAL FORM INCLUDING APPROVED COPIES OF THE FOLLOWING, REVISED IF NECESSARY TO SHOW SYSTEM AND EQUIPMENT AS ACTUALLY INSTAI I PT). MANUFACTURERS CATALOG SHEETS WIRING DIAGRAMS MAINTENANCE INSTRUCTIONS OPERATING INSTRUCTIONS PARTS LISTS CONTRACTOR SHALL ALSO PROVIDE ADEQUATE VERBAL INSTRUCTIONS OF SYSTEM OPERATION TO OWNER'S REPRESENTATIVE AT THE TERMINATION OF THE WORK. ICA 1-12 START UP OF SYSTEMS. PRIOR TO STARTUP OF THE ELECTRICAL SYSTEMS, THE CONTRACTOR SHALL GHEGK ALL COMPONENTS AND DEVICES, LUBRICATE ITEMS ACCORDINGLY, AND TIGHTEN ALL SCREWED AND BOLTED CONNECTIONS. ADJUST TAPS ON EACH TRANSFORMER FOR RATED SECONDARY VOLTAGE. GHEGK AND RECORD BUILDING'S SERVICE ENTRANCE VOLTAGE, GROUNDING CONDITIONS, GROUNDING RESISTANCE AND PROPER PHASING. BALANCE ALL SINGLE PHASE LOADS AT EACH PANELBOARD, REDISTRIBUTING BRANCH CIRCUIT CONNECTIONS UNTIL BALANCE 15 ACHIEVED. Design new INTERIORS LTo Ni Design 11 Talcott Notch Road Farmington, CT 06032 T. 860 • 678 • 1946 F. 860 • 678 • 7111 nidesign@nidesign.net © 2013 ISA I-13 GUARANTEE. GUARANTEE AGAINST DEFECTIVE WORKMANSHIP AND MATERIAL FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL PAYMENT. GUARANTEE SHALL INCLUDE MATERIAL TO BE REPLACED AND ALL LABOR REQUIRED. ISA 1-14 MISCELLANEOUS REMODELING WORK. PROVIDE ALL ITEMS OF ELECTRICAL SYSTEMS MODIFICATION REQUIRED BECAUSE OF BUILDING REMODELING, AS NOTED ON THE DRAWINGS, OR NECESSARY FOR PROPER OPERATION. 16A2 ELECTRICAL- INSTALLATION. ISA 2-1 EXCAVATION AND BACKFILLING. DO ALL EXCAVATION OF ALL MATERIALS ENCOUNTERED INCLUDING ROCK REQUIRED FOR WORK UNDER THIS SECTION. BACKFILL ALL TRENCHES, TAMPING WELL IN 6" LAYERS. SYSTEM SHALL BE TESTED, MADE TIGHT AND ACCEPTED BEFORE BACKFILL. REMOVE FROM PREMISES ALL EXCESS MATERIAL NOT USED IN BACKFILLING. REPAIR ALL STREETS, SIDEWALKS, DRIVES, PAVING, ETC. DAMAGED. REPAIR MATERIALS SHALL GENERALLY MATCH EXISTING CONSTRUCTION. ALL BACKFILLING AND REPAIRING SHALL MEET ALL REQUIREMENTS OF THE CITY AND OTHERS HAVING JURISDICTION. REPAIR WORK SHALL BE THOROUGHLY FIRST GLASS. CONFORM TO ALL REQUIREMENTS OF DIVISION TWO OF THIS SPECIFICATION. ISA 2-2 GLEANING. DIRT AND REFUSE RESULTING FROM THE PERFORMANCE OF THE WORK SHALL BE REMOVED FROM THE PREMISES AS REQUIRED TO PREVENT ACCUMULATION. THE CONTRACTOR SHALL COOPERATE IN MAINTAINING REASONABLY CLEAN PREMISES AT ALL TIMES. IMMEDIATELY PRIOR TO FINAL INSPECTION, THE CONTRACTOR SHALL MAKE A FINAL CLEANUP OF DIRT AND REFUSE RESULTING FROM 1415 WORK. THE CONTRACTOR SHALL GLEAN ALL MATERIAL AND EQUIPMENT INSTALLED UNDER THE ELECTRICAL CONTRACT. DIRT, DUST, PLASTER, STAINS AND FOREIGN MATTER SHALL BE REMOVED' FROM ALL SURFACES. DAMAGED FINECI I , SHALL BE TOUGHED UP AND RESTORED TO THEIR ORIGINAL CONDITION. ISA 2-3 GUTTING AND PATCHING. THIS CONTRACTOR SHALL DO ALL GUTTING OF WALLS, FLOORS, CEILINGS, ETC. AS REQUIRED TO INSTALL WORK UNDER 11415 SECTION. CONTRACTOR SHALL OBTAIN PERMISSION OF THE ARCHITECT BEFORE DOING ANY GUTTING. ALL HOLES SHALL BE GUT A5 SMALL AS POSSIBLE. CONTRACTOR SHALL PATCH WALLS, FLOORS, ETC. AS REQUIRED BY WORK UNDER THIS SECTION. ALL PATCHING SHALL BE THOROUGHLY FIRST GLASS AND SHALL MATCH THE ORIGINAL MATERIAL AND CONSTRUCTION. ISA 2-4. ROUGH -IN. COORDINATE WITHOUT DELAY ALL ROUGHING -IN WITH GENERAL CONSTRUCTION. ALL CONDUIT ROUGH -IN SHALL BE CONGEALED EXCEPT IN UNFINISHED AREAS AND WHERE OTHERWISE SHOWN. ISA 2-5 CONDUIT. ALL GONDUIT SHALL BE RUN CONGEALED EXCEPT WHERE OTHERWISE NOTED. ALL CONDUIT RUN UNDERGROUND, EXPOSED TO WEATHER, OR OTHER HAZARDOUS CONDITIONS SHALL BE RIGID. ALL OTHER CONDUIT MAY BE THIN-WALL WHERE APPROVED BY LOCAL CODE. AT CONTRACTOR'S OPTION, PVC: CONDUIT (WITH GROUND WIRE) MAY BE USED WHERE PERMITTED BY CODE. FINAL CONNECTION' TO EACH MOTOR AND TRANSFORMER AND TO ANY DEVICE WHICH WOULD OTHERWISE TRANSMIT MOTION, VIBRATION OR NOISE, SHALL BE IN FLEXIBLE METAL CONDUIT. WHERE FLEXIBLE METAL CONDUIT 15 EXPOSED TO LIQUIDS, VAPORS OR SUNLIGHT, LIQUID -TIGHT FLEXIBLE METAL CONDUIT SHALL BE USED. ALL FLEXIBLE METAL CONDUIT SHALL BE PROVIDED WITH AN INSULATED GROUND WIRE. ISA 2-6 CONDUIT INSTALLATION. A. ALL WIRING SHALL BE RUN IN CONDUIT OR BE TYPE MG CABLE WHERE SPECIFIED A5 ACCEPTABLE. MAXIMUM LENGTH OF RUN FOR MG GABLE 15 6'-O". B. CONDUIT SHALL BE INSTALLED CONGEALED ABOVE SUSPENDED CEILINGS OR CONCEALED IN WALLS OR FLOORS WHEREVER POSSIBLE. FOR MULTISTORY BUILDINGS, CONDUIT SHALL BE INSTALLED CONCEALED IN CEILING PLENUM OF SPACE BELOW AND SHALL NOT INTERFERE WITH EXISTING TENANT PLENUM MECHANICAL, ELECTRICAL AND PLUMBING SYSTEMS. RUN PARALLEL TO BUILDING LINE -5. G. CONDUIT SHALL BE INSTALLED TO REQUIREMENTS OF STRUCTURE AND TO REQUIREMENTS OF ALL OTHER WORK ON THE PROJECT. CONDUIT SHALL BE INSTALLED TO CLEAR ALL OPENINGS, DEPRESSIONS, PIPES, DUCTS, REINFORCING STEEL, ETG. CONDUIT SET IN FORMS FOR CONCRETE STRUCTURE SHALL BE INSTALLED IN. SUCH A MANNER THAT INSTALLATION WILL NOT AFFECT THE STRENGTH OF THE STRUCTURE. EXCEPT WHERE APPROVED IN WRITING BY THE ARCHITECT, NO CONDUIT SHALL BE RUN IN A CONCRETE SLAB. CONDUIT SHALL BE LOCATED IN GRANULAR FILL BELOW SLABS ON GRADE OR IN PLENUM SPACE. D. CONDUITS SHALL BE INSTALLED CONTINUOUS BETWEEN CONNECTIONS TO OUTLETS, BOXES AND CABINETS WITH A MINIMUM POSSIBLE NUMBER OF BENDS AND NOT MORE THAN THE EQUIVALENT OF FOUR 40 DEGREE BENDS BETWEEN CONNECTIONS. BENDS SHALL BE SMOOTH AND EVEN AND SHALL BE MADE WITHOUT FLATTENING CONDUIT OR FLAKING ENAMEL. RADIUS OF BENDS SHALL BE AS LONG AS POSSIBLE AND NEVER SHORTER THAN THE CORRESPONDING TRADE ELBOW. LONG RADIUS ELBOWS SHALL BE USED WHERE NECESSARY. E. CONDUITS SHALL BE SECURELY FASTENED IN PLACE WITH APPROVED STRAPS, HANGERS AND STEEL SUPPORTS AS REQUIRED. SINGLE CONDUITS FOR FEEDERS SHALL BE HUNG WITH MALLEABLE SPLIT RING HANGERS WITH ROD AND TURNBUCKLE SUSPENSION FROM INSERTS SPADED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE. GROUPS OF HORIZONTAL FEEDER CONDUITS SHALL BE CLAMPED TO UNISTRUT STEEL CHANNELS AND SUSPENDED FROM INSERTS SPACED NOT OVER 10 FEET APART IN CONSTRUCTION ABOVE._ VERTICAL FEEDER CONDUITS SHALL BE SECURELY CLAMPED TO STRUCTURAL STEEL MEMBERS ATTACHED TO STRUCTURE. CABLE CLAMPS SHALL BE INSTAI 1 FD FOR SUPPORT OF VERTICAL FEEDERS WHERE REQUIRED. CONDUIT SUPPORTS SHALL BE ADDED WITHIN 12" AT ONE END OF ALL BENDS. CONDUIT SHALL NOT BE SUPPORTED FROM SUSPENDED CEILING COMPONENTS, DUCT WORK OR PIPING. F. CONDUIT ENDS SHALL BE REAMED BEFORE INSTALLATION AND ALL CONDUIT SHALL BE THOROUGHLY GLEANED, BEFORE INSTALLATION AND KEPT GLEAN AFTER INSTALLATION. OPENINGS AND BOXES SHALL BE PLUGGED OR COVERED AS REQUIRED TO KEEP CONDUIT CLEAN DURING CONSTRUCTION AND ALL CONDUIT SHALL BE FISHED CLEAR OF OBSTRUCTIONS BEFORE THE PULLING OF WIRES. ALL CONDUIT SHALL BE OF AMPLE SIZE FOR PULLING OF WIRE AND SHALL NOT BE SMALLER THAN CODE REQUIREMENTS AND NOT LESS THAN 1/2" 114 SIZE. G. ALL ELECTRICAL WORK SHALL BE PROTECTED AGAINST DAMAGE DURING CONSTRUCTION. ANY WORK DAMAGED OR MOVED OUT OF LINE AFTER ROUGHING -IN SHALL BE REPAIRED TO MEET ENGINEER'S APPROVAL WITHOUT ADDITIONAL COST TO THE OWNER. 14. CONDUIT TERMINATIONS AT PANELBOARDS, SWITCHBOARDS, MOTOR CONTROL EQUIPMENT AND JUNCTION BOXES SHALL BE ALIGNED AND INSTALLED TRUE AND PLUMB. I. INSTALL APPROVED EXPANSION FITTINGS WHERE CONDUIT OR EMT PASSES THROUGH EXPANSION JOINTS. J. INSTALL A PULL WIRE IN EACH EMPTY CONDUIT WHICH 15 LEFT BY THE CONTRACTOR FOR INSTALLATION OF WIRES OR GABLES BY OTHERS. K. MAKE ALL JOINTS AND CONNECTIONS IN A MANNER WHICH WILL INSURE MECHANICAL STRENGTH AND ELECTRICAL CONTINUITY. L. THRU-WIRING OF LIGHT FIXTURES 15 NOT PERMITTED. M. METALLIC CONDUIT IN DIRECT CONTACT WITH EARTH SHALL BE COATED WITH AN ASPHALT BASE PAINT UL. LISTED FOR THIS APPLICATION. ISA .2-1 BUSHINGS AND LOCKNUTS. WHERE CONDUITS ENTER BOXES, THEY SHALL BE RIGIDLY CLAMPED TO THE BOX BY A BUSHING ON THE INSIDE AND A LOCKNUT ON THE OUTSIDE, AND CONDUIT SHALL ENTER THE BOX SQUARELY. BUSHINGS AND LOCKNUTS SHALL BE MADE OF GALVANIZED MALLEABLE IRON AND SHALL HAVE SHARP, GLEAN -CUT THREADS. WHERE THIN-WALL CONDUIT ENTERS BOX, PROVIDE APPROVED E.M.T. CONNECTORS. USE INSULATED GROUNDING BUSHINGS WHEREVER CONNECTION 15 SUBJECT TO VIBRATION OR MOISTURE. ICA 2-8 WIRE. ALL WIRE SHALL HAVE COPPER CONDUCTORS, WITH UL. LABEL, AND 600 VOLT INSULATION. ALL WIRE SHALL BE RUN 114 CONDUIT, INCLUDING LOW VOLTAGE WIRING. SERVICE ENTRANCE GABLE SHALL BE TYPE USE, THWN OR XHHN WITH STRANDED CONDUCTORS. ALL FEEDER AND BRANCH CIRCUITS WIRE #8 AWG AND LARGER SHALL BE TYPE THINN OR XHHW, BOTH WITH STRANDED CONDUCTORS. ALL WIRE *10 AWG AND SMALLER SHALL BE TYPE THWN (WET OR DAMP LOCATIONS, OR IN CONDUIT BELOW GRADE OR SLAB) OR THHN (DRY LOCATIONS ONLY AND ABOVE GRADE), BOTH WITH SOLID CONDUCTORS. WIRE WITHIN FLUORESCENT FIXTURE CHANNELS SHALL BE TYPE THHN. ALL BRANCH CIRCUIT WIRING SHALL BE NOT SMALLER THAN *12 AWG WIRE. IF NO WIRE SIZE 15 INDICATED ON THE PLANS FOR A BRANCH CIRCUIT, PROVIDE 41I2AWG WIRE AND A 20A CIRCUIT BREAKER. CONTROL WIRING SHALL HAVE 600V INSULATION AND BE OF THE PROPER TYPE, SIZE AND NUMBER A5 REQUIRED TO ACCOMPLISHED SPECIFIED FUNCTION. CONSULTANTS 12035 COLWICK Project Management * Design SAN ANTONIO, TX 78216 ISA 2-4 WIRING INSTALLATION. A. ALL WIRING, INCLUDING LOW VOLTAGE, SHALL BE INSTALLED IN APPROVED RACEWAY AND ENCLOSURES. 5. SUPPORT ALL WIRE AND GABLES 114 VERTICAL INSTALLATIONS AS REQUIRED BY CODE BY INSTALLING GABLE SUPPORTERS OR PLUG -TYPE CONDUIT RISER SUPPORTS. G. ALL WIRE AND GABLE IN CONDUIT SHALL BE CONTINUOUS WITHOUT TAPS OR SPLICES. ALL SPLICES OR TAPS SHALL OCCUR IN APPROVED BOXES AND ENCLOSURES AND SHALL BE KEPT TO THE MINIMUM REQUIRED, AND SHALL BE MADE UP OF APPROVED SOLDERLESS CONNECTORS. ALL SPLICES, TAPS, AND JOINTS SHALL BE INSULATED AS REQUIRED BY CODE. D. ALL MATERIALS USED TO TERMINATE, SPLICE OR TAP CONDUCTORS SHALL BE DESIGNED FOR, PROPERLY SIZED FOR, AND U.L. LISTED FOR THE SPECIFIC APPLICATION AND CONDUCTORS INVOLVED, AND SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS, USING THE MANUFACTURER'S RECOMMENDED TOOLS. E. WHERE WIRE 15 INDICATED TO BE INSTALLED, BIT THE CONNECTION 15 INDICATED "FUTURE" OR "BY OTHERS", CONTRACTOR 5HALL LEAVE A MINIMUM OF 5 FEET OF "PIGTAIL" AT THE BOX, TAPE THE ENDS OF THE CONDUCTORS, AND COVER THE BOX. F. THE NUMBER OF CONDUCTORS IN A SPECIFIC CONDUIT RUN ARE INDICATED WITH GROSS LINES 014 EACH "CONDUIT RUN" 014 THE DRAWINGS. IN GENERAL, DIRECTION OF BRANCH CIRCUIT "HOME RUN" ROUTING 15 INDICATED ON THE DRAWINGS, COMPLETE WITH CIRCUIT NUMBERS AND PANELBOARD DESIGNATION. THIS CONTRACTOR SHALL CONTINUE ALL SUCH "HOME RUN" WIRING TO THE DESIGNATED PANELBOARD, AS THOUGH "CONDUIT RUNS" WERE INDICATED IN THEIR ENTIRETY. G. CONDUCTORS SHALL HAVE INSULATION OF THE PROPER DOLOR TO MATCH NEC COLOR CODE SYSTEM AND IN THE TABLE BELOW. IN LARGER WIRE SIZES WHERE PROPERLY COLORED INSULATION IS NOT AVAILABLE, THE CONTRACTOR SHALL USE VINYL PLASTIC ELECTRICAL TAPE OF THE APPROPRIATE COLOR AROUND EACH CABLE AT ALL TERMINATION POINTS, JUNCTION AND PULL BOXES. SYSTEM VOLTAGE 205Y/120 NEUTRAL -WHITE PHASE A OR LI -BLACK PHASE 8 OR L2 -RED PHASE C OR L3 -BLUE GROUND -GREEN 480Y/2T1 NEUTRAL - WHITE WITH TRACER OR GRAY PHASE A OR LI - BROWN PHASE B OR L2 -ORANGE PHASE C OR L3-YELLO11 GROUND -GREEN WITH TRACER H. ALL TERMINAL BLOCKS AND WIRE TERMINALS FOR CONTROL WIRING SHALL BE PROPERLY NUMBERED FOR IDENTIFICATION WITH VINYL 511GK--ON MARKERS OR EQUIVALENT. I. ALL RECEPTACLE AND NON -LIGHTING EQUIPMENT BRANCH CIRCUITS SHALL HAVE AN EQUIPMENT GROUND CONDUCTOR INSTALLED 114 THE BRANCH CIRCUIT RACEWAY, SIZED IN ACCORDANCE WITH NEG TABLE 250-q5. J. VOLTAGE DROP IN BRANCH CIRCUITS SHALL NOT EXCEED 2%. ISA 2-10 JUNCTION BOXES, PULL BOXES CABINETS AND WIREWAYS. PROVIDE JUNCTION BOXES, PULL BOXES, CABINETS AND WIREWAYS WHEREVER NECESSARY FOR PROPER INSTALLATION OF VARIOUS ELECTRICAL SYSTEMS ACCORDING TO THE NATIONAL ELECTRICAL CODE AND WHERE INDICATED ON THE DRAWINGS. SIZE A5 REQUIRED FOR THE SPECIFIC FUNCTION OR AS REQUIRED BY THE NATIONAL ELECTRICAL CODE, WHICHEVER 15 LARGEST. CONSTRUCTION SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT INSTALLED. ISA 2-11 OUTLET BOXES. ALL OUTLETS INCLUDING LIGHT, SWITCH, RECEPTACLE, AND SIMILAR OUTLETS, SHALL BE NATIONAL ELECTRICAL, APPLETON, STEEL CITY, RACO OR APPROVED EQUAL GALVANIZED STEEL KNOCKOUT BOXES, SUITABLE IN DESIGN TO THE PURPOSE THEY SERVE AND THE SPACE THEY OCCUPY. SIZE AS REQUIRED FOR THE SPECIFIC FUNCTION OR A5 REQUIRED BY THE NATIONAL ELECTRICAL CODE, WHICHEVER 15 LARGEST. ALL OUTLET BOXES SHALL BE SET IN WALLS, COLUMNS, FLOORS, OR CEILINGS 50 AS TO BE FLUSH YVITH THE FINISHED SURFACE AND BE ACCURATELY SET AND RIGIDLY SECURED IN POSITION. PROVIDE PLASTER RINGS, EXTENSION RINGS AND MASONRY RINGS AS REQUIRED FOR FLUSH MOUNTING. J6A 2-12 OUTLET LOCATIONS. OUTLETS ARE ONLY APPROXIMATELY LOCATED' ON THE SMALL SCALE PLANS, AND GREAT CARE MUST BE USED IN THE ACTUAL LOCATION BY CONSULTING THE VARIOUS LARGE SCALE DETAILED DRAWINGS USED BY OTHER CONTRACTORS, AND BY SECURING DEFINITE LOCATIONS FROM THE ARCHITECT. THE HEIGHT OF THE CENTER OF OUTLETS ABOVE THE FINISHED FLOOR, IF NOT OTHERWISE SPECIFIED OR SHOWN ON THE DRAWINGS, SHALL GENERALLY BE AS FOLLOWS: SWITCH OUTLETS 48" ABOVE FLOOR TO TOP OF OUTLET WALL RECEPTACLES 15" ABOVE FLOOR TO BOTTOM OF OUTLET DEVICES ABOVE COUNTERS 10" ABOVE COUNTER TO TOP OF OUTLET ISA 2-13 WIRING DEVICES. FURNISH AND INSTALL THE FOLLOWING OUTLETS AND SWITCHES WHERE SHOWN OR REQUIRED. MINOR CHANGES RELATIVE TO THE LOCATION OF ELECTRICAL EQUIPMENT MAY BE MADE BY THIS CONTRACTOR TO COMPLY WITH STRUCTURAL ANDD. BUILDING REQUIREMENTS A5 DETERMINED 114 THE COURSE OF CONSTRUCTION. ALL OUTLETS AND SWITCHES MUST BE OF THE SAME MANUFACTURER AND NOT MIXED 014 THE PROJECT. COLOR OF TOGGLES AND RECEPTACLES SHALL BE A5 REQUESTED BY THE ARCHITECT: DUPLEX RECEPTACLE: PASS 4 SEYMOUR #5352 SINGLE POLE SWITCH: PASS 4 SEYMOUR #20ACI THREE-WAY SWITCH: PASS 4 SEYMOUR #20AC3 OCCUPANCY SENSOR SWITCH: WATT STOPPER *15120/211 IVORY MOMENTARY SWITCH: PA55 4 SEYMOUR *1221 (CONTROLS CONTACTOR) PILOT LIGHT SWITCH: PASS 4 SEYMOUR #20ACI-RPL KEY SWITCH: PASS 4 SEYMOUR #20ACI-L ISOLATED GROUND RECEPTACLE: PASS 4 SEYMOUR #168300 GFGI DUPLEX RECEPTACLE: PASS 4 SEYMOUR #2041 WALL -BOX DIMMER SWITCH: LUTRON ARIADNI AY -IOP -IV (1000W) IVORY SAFETY RECEPTACLE: PASS 4 SEYMOUR *515-62 (NEMA 5-I5R) DUPLEX RECEPTACLE BRYANT *GBR20 MEMA5-20R) QUADPLEX RECEPTACLE BRYANT 4121254-1 (NEMAS-20R) CASHIER STATION 3 -GANG FLOORBOX: HUBBELL #84333* 3 -GANG CARPET FLANGE: HUBBELL #583085 * DUPLEX PLAP: HUBBELL #53825 * CAT 5 JACKS (4): HUBBELL 14HBL5ESK GAT 5 RECEPTACLE: HUBBELL 41DJI06BK * * NOTE: FOR USE IN SLAB CUT/TRENCHING APPLICATIONS (REQUIRES 15" MINIMUM WIDE TRENCH. ORIENT BOX PARALLEL TO TRENCH TO ALLOW FOR CONDUIT SWEEP) CASHIER STATION GORE DRILL FLOOR BOX: HUBBELL #PT4XGY2C ** GAT 5/RECEPTACLES: HUBBELL' *PT4XGAT5 ** ** NOTE: FOR USE IN CORE DRILL APPLICATIONS. (REQUIRES 3" DIAMETER GORE) IN SALES AREA, DEVICES INSTALLED IN MILLWORK SHALL BE WHITE. ALL OTHER AREAS DEVICES TO BE IVORY. VERIFY DEVICE DOLOR WITH ARCHITECT PRIOR TO INSTALLATION. ISOLATED GROUND RECEPTACLES TO BE WHITE. EQUIVALENT HUBBELL, LEVITON, AND COOPER WIRING DEVICES WILL BE ACCEPTABLE. OTHER DEVICES SHOWN 014 THE PLANS BUT NOT GALLED OUT ABOVE SHALL BE OF THE SAME CONSTRUCTION QUALITY AS DEFINED BY THE MODEL NUMBERS SHOWN. DUPLEX RECEPTACLES, INSTALLED VERTICALLY, SHALL BE INSTALLED WITH THE GROUNDING TERMINAL "UP" ISA 2-14 SWITCH AND OUTLET COVER PLATES. ALL SWITCH AND OUTLET PLATES SHALL BE P45 IVORY 114 STORAGE ROOM, TOILET AND CLOSET; IVORY WHERE INSTALLED IN SALES AREA WALLS WITH COVERINGS; WHITE WHERE INSTALLED IN SALES AREA CEILING AND IN MILLWORK. VERIFY DESIRED MATERIAL WITH ARCHITECT BEFORE INSTALLATION. SWITCH PLATES IN UNFINISHED ROOMS AND SPACES SHALL BE STAMPED STEP' PLATES, CADMIUM PLATED. GROUPS OF SWITCHES SHALL BE UNDER ONE GANG -PLATE, USUALLY .MOUNTED HORIZONTALLY; WHERE REQUIRED BY DETAILS, VERTICAL MOUNTING SHALL BE USED INSTEAD. PLATES SHALL BE SET PLUMB, PARALLEL, AND SHALL FINISH FLUSH WITH THE WALL. DRAWIhqG illtlal° Nlau4 4d1oIIi`o; description: n„ • 5 . 6 . 13 ISSUED TO CLIENT FOR FINAL REVIEW 5 . 1 . 13 ISSUED TO LANDLORD FOR FINAL REVIEW 5 . 10 . 13 ISSUED FOR BID 4 PERMIT PEPOI P1/4" Q il%WO ISA 2-15 WEATHERPROOF DOVER PLATES, WEATHERPROOF OUTLETS TO BE GROUND FAULT PROTECTED. PROVIDE INTERMATIG #WP1010 WEATHERPROOF COVER. THE COVER SHALL BE MOLDED FROM A CLEAR 141G14 IMPACT ULTRAVIOLET STABILIZED POLYCARBONATE MATERIAL FOR EASY VERIFICATION THAT CORDS ARE PLUGGED 114 AND THAT THE GFGI 15 FUNCTIONING ISA 2-16 FIRESTOPPING OF FLOOR AND WALL PENETRATIONS. THIS CONTRACTOR SHALL SEAL ALL PENETRATIONS THROUGH FIRE RATED FLOOR ANT) WALL ASSEMBLIES IN ACCORDANCE WITH NFPA CODES AND UL WALL CONSTRUCTION TYPES. THE SEALING SYSTEM MUST BE CAPABLE OF PASSING A THREE HOUR TEST, PER ASTM E-814 (UL 141q). PENETRATION SEALING SYSTEM SHALL BE, AT A MINIMUM, 3M BRAND 1404 (GP -25 CAULK, OR 303 PUTTY), OR APPROVED EQUAL, AND SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ISA 2-11 FLASHING AND PITCH POCKETS. FLASH AND GOUNTERFLASH ALL OPENINGS THROUGH ROOF; AND/OR PROVIDE PITCH POCKETS A5 REQUIRED. ALL ROOF PENETRATIONS SHALL BE LEAKTIGHT AT THE TERMINATION OF THE WORK. J6A 2-18 CONCRETE BASES. CONTRACTOR SHALL FURNISH CONCRETE BASES FOR 1415 EQUIPMENT WHERE INDICATED 014 THE DRAWINGS. ISA 2-14 ACCESS DOORS. PROVIDE ACCESS DOORS IN CEILINGS, WALLS, ETC. WHERE INDICATED OR REQUIRED FOR ACCESS OR MAINTENANCE TO WORK INSTALLED UNDER THIS SECTION, MILGOR OR EQUIVALENT. ISA 2-20 EQUIPMENT IDENTIFICATION. THIS CONTRACTOR 51-1ALL FURNISH AND INSTALL EQUIPMENT IDENTIFICATION NAMEPLATES ON ALL PANELBOARDS, SWITCHES, STARTERS, DIMMERS, ETC., INCLUDING SWITCHES IN DISTRIBUTION PANELS. NAMEPLATES SHALL BE ENGRAVED PHENOLIC PLASTIC, AND 51-1ALL BE FIRMLY ATTACHED TO THE EQUIPMENT. NAMEPLATES SHALL CLEARLY IDENTIFY EACH ITEM AND WHAT IT CONTROLS. ISA3 ELECTRICAL SERVICE AND GROUNDING ISA 3-1 ELECTRICAL SERVICE. SEE DRAWINGS FOR TYPE, SIZE, VOLTAGE, PHASE, ETC. ISA 3-2 CONNECTION TO SERVING UTILITIES. SEE DRAWINGS FOR INFORMATION REGARDING THE ELECTRICAL CONNECTION TO THE EXISTING LANDLORD'S/OWNER'S ELECTRICAL SERVICE. VERIFY THE SIZE, LOCATION, VOLTAGE, ETG., OF THE EXISTING DISTRIBUTION EQUIPMENT PRIOR TO CONSTRUCTION. PROVIDE ALL NECESSARY EQUIPMENT FOR TENANT'S CONNECTION TO THE EXISTING ELECTRICAL DISTRIBUTION SYSTEM. ISA 3-3 GROUNDING. THE ELECTRICAL SERVICE, ALL TRANSFORMERS, CONDUCTORS, CONDUITS, MOTOR FRAMES, ETG. IN THIS CONTRACT WHICH REQUIRE GROUNDING SHALL BE PERMANENTLY AND EFFECTIVELY GROUNDED BY THIS CONTRACTOR IN A THOROUGH AND EFFICIENT MANNER IN CONFORMANCE TO THE NATIONAL ELECTRICAL CODE. 16A4 DISTRIBUTION AND CONTROL EQUIPMENT ISA 4-1 CIRCUIT BREAKERS IN EXISTING PANELBOARDS. NEW CIRCUIT BREAKERS REQUIRED TO BE INSTALLED IN EXISTING PANELBOARDS SHALL BE OF THE SAME MANUFACTURER, TYPE AND HAVE THE SAME AIG RATINGS AS THE EXISTING PANELU3OARD CIRCUIT BREAKERS. ISA 4-2 PANELBOARDS. INSTALL PANELBOARDS FURNISHED BY OWNER A5 SCHEDULED AND LOCATED ON DRAWINGS. EACH PANEL SHALL CONTAIN A TYPEWRITTEN CARD DIRECTORY INDICATING EXACTLY WHAT EACH CIRCUIT CONTROLS. PANELBOARD SUPPLIED COMPLETE WITH BOLT ON THERMAL MAGNETIC, MOLDED CASE CIRCUIT BREAKERS ASSEMBLED 114 A DEAD FRONT FINISHED CABINET, FULLY RATED AND WITH THE INTEGRATED SHORT CIRCUIT CURRENT RATINGS INDICATED ON THE DRAWINGS. PLUG 114 TYPE BREAKERS WILL NOT BE ACCEPTABLE. ALL TWO AND THREE POLE BREAKERS: COMMON TRIP TYPE. BREAKERS USED A5 SWITCHES FOR 120V OR 211V LIGHTING CIRCUITS: APPROVED FOR THE PURPOSE AND MARKED "SW)". ISA 4-3 DISCONNECT SWITCHES. CONTRACTOR 51-hALL FURNISH AND INSTALL SQUARE D, SEIMENS, CUTLER HAMMER, OR GENERAL ELECTRIC FUSED OR NON-FUSED (AS NOTED OR REQUIRED) NEMA HEAVY DUTY EXTERNALLY OPERATED SAFETY SWITCHES AND MOTOR STARTERS WHERE NOT FURNISHED. WITH THE STARTING EQUIPMENT, AND AT ALL OTHER POINTS REQUIRED 51' CODE. FUSE HOLDERS SHALL HAVE CLASS R REJECTION FEATURE. CONSTRUCTION SHALL BE OF A NEMA DESIGN SUITABLE FOR THE ENVIRONMENT INSTALLED IN. ISA 4-4 FUSES. PROVIDE EACH CIRCUIT AND SET OF FUSE CLIPS THROUGHOUT THE WORK WITH BUSSMANN, FERRAZ SHAWMUT, OR LITTLEFUSE FUSES, SIZES AND TYPES AS REQUIRED OR INDICATED. ALL FUSES LARGER THAN 6OOA: UL GLASS L, SIMILAR TO TYPE KRP-G BUSSMANN LOW PEAK OR EQUAL. FUSES USED TO PROTECT MOTORS: UL GLASS RKS, BUSSMANN FUSETRON OR EQUAL. FUSES USED TO PROTECT ALL OTHER ELECTRICAL EQUIPMENT: UL GLASS RKI, DUAL ELEMENT, BUSSMANN LPS/LPN OR EQUAL. ALL FUSED DEVICES SHALL BE LABELED AS TO TYPE AND SIZE OF FUSE REQUIRED. ISA 4-5 SPARE FUSES. FURNISH THREE SPARE FUSES OF EACH SIZE AND TYPE USED ON THE PROJECT (EXCEPT MAIN SWITCH FUSES), NEATLY CONTAINED IN A PROPERLY LABELED CABINET. ISA 4-6 HAGR CIRCUIT BREAKERS. PROVIDE AN HAGR CIRCUIT BREAKER FOR EACH CIRCUIT CONNECTED TO HVAG OR. REFRIGERATION EQUIPMENT MOTOR LOAD. HAGR CIRCUIT BREAKERS INSTALLED IN PANEL BOARDS SHALL BE OF THE SAME MANUFACTURER, TYPE, AND AIG RATINGS AS THE EXISTING AND/OR NEW PANEL BOARD CIRCUIT BREAKERS. ISA 4-1 DRY -TYPE TRANSFORMERS. INSTALL TRANSFORMERS FURNISHED BY YGG. MOUNT ON VIBRATION ISOLATION PADS WITH A .25" STATIC DEFLECTION. CONDUIT CONNECTIONS TO TRANSFORMERS SHALL BE MADE WITH FLEXIBLE CONDUIT WITH AT LEAST 6" OF SLACK 114 ALL DIRECTIONS. 16A5 LIGHT FIXTURES. LAMPS AND BALLASTS ISA 5-1 LIGHT FIXTURE LOCATIONS. LIGHT FIXTURES SHOWN ON THE ELECTRICAL DRAWINGS REPRESENT GENERAL ARRANGEMENTS ONLY. REFER TO ARCHITECTURAL DRAWINGS FOR MORE EXACT LOCATIONS. COORDINATE LOCATION WITH ALL OTHER TRADES BEFORE INSTALLATION TO AVOID CONFLICTS. LIGHT FIXTURES LOCATIONS IN MECHANICAL ROOMS. SHALL BE COORDINATED WITH FINAL INSTALLED PIPING AND DUCTWORK LAYOUTS. 16A 5-2 LIGHT FIXTURES. PROVIDE LIGHT FIXTURE -5 NOT FURNISHED BY THE OWNER AS SCHEDULED ON DRAWINGS. THI5 SHALL INCLUDE ALL LAMPS, MATERIAL AND LABOR TO SECURELY HANG FIXTURES, CLEAN THEM AND MAKE THEM COMPLETELY READY FOR USE. ALL LIGHT FIXTURES SHALL INCLUDE ALL NECESSARY ACCESSORIES REQUIRED. LIGHT FIXTURE MODELS SCHEDULED ON THE DRAWINGS ARE TO SHOW THE MANUFACTURER, GRADE AND STYLE OF FIXTURES REQUIRED ONLY. PROVIDE ALL HANGERS, SUPPORTS, AND MISCELLANEOUS HARDWARE REQUIRED TO INSTALL LIGHT FIXTURES. PROVIDE PROPER TRIM TO FIT EACH CEILING CONDITION ENCOUNTERED. PROVIDE ADDITIONAL TIE WIRES CONNECTED TO STRUCTURE TO CONFORM TO UBC 47-18 SEISMIC REQUIREMENTS; WHERE REQUIRED. INSTALL ALL FIXTURES AND LAMPS FURNISHED BY THE OWNER. AIM ALL TRACK LIGHTING A5 DIRECTED BY THE OWNER. THE OWNER WILL PROVIDE LAMPS FOR OWNER FURNISHED FIXTURES ONLY. ISA 5-3 LAMPS. LAMPS FOR ALL LIGHTING FIXTURES NOT FURNISHED BY THE OWNER SHALL BE PROVIDED AND INSTALLED BY THIS CONTRACTOR. PROVIDE LAMPS INDICATED 014 THE DRAWINGS, OR NOT INDICATED, AS RECOMMENDED BY THE FIXTURE MANUFACTURER. 114 ALL GASES LAMPS SHALL BE COMPATIBLE WITH SPECIFIED FIXTURE. LAMPS SHALL BE MANUFACTURED BY GENERAL ELECTRIC, OSRAM/SYLVANIA, PHILLIPS, OR VENTURE. ALL FLUORESCENT LAMPS SHALL BE COOL WHITE, UNLESS NOTED OR DIRECTED OTHERWISE. ALL FLUORESCENT LAMPS IN BACKROOM AREAS SHALL BE 3500 DEGREE KELVIN AND A COLOR RENDERING INDEX OF 15. INCANDESCENT LAMPS SHALL BE TYPE AND WATTAGE A5 SHOWN ON THE DRAWINGS AND SHALL BE 130 VOLT UNLESS OTHERWISE SCHEDULED OR SPECIFIED. ICA 5-4 BALLASTS. ALL FLUORESCENT BALLASTS: SHALL BE THERMALLY PROTECTED AGAINST OVERHEATING; SHALL BE ETL-CBM, GLASS P TO MEET ALL REQUIREMENTS OF SECTION 410-13 (E) OF THE NEC A5 A MINIMUM; SHALL COMPLY WITH THE NATIONAL BALLAST ENERGY LAW; SHALL HAVE A MINIMUM 40% POWER FACTOR; SOUND LEVELS SHALL NOT EXCEED CLASS A AMBIENT NOISE LEVELS; AND SHALL BE LOW HEAT TYPE. Electrical Specifications 5. 10. 13 dra \ "1i I se clg ,19ei AS NOTED jEr INDOOR FLUORESCENT BALLASTS: SHALL BE ELECTRONIC TYPE SUITABLE FOR OPERATION OF T8 LAMPS; SHALL HAVE A TOTAL HARMONIC DISTORTION LESS THAN 20%; SHALL HAVE A FREQUENCY OF OPERATION OF 20 KHZ OR GREATER AND OPERATE WITH 140 VISIBLE FLICKER; SHALL WITHSTAND LINE TRANSIENTS AS DEFINED IN ANSI/IEEE 062.41, CATEGORY A; AND SHALL BE ADVANCE REL/VEL SERIES OR EQUAL OF MAGNETEK, MOTOROLA OR OSRAM. COMPACT FLUORESCENT BALLASTS: SHALL BE THERMALLY PROTECTED AGAINST OVERHEATING; SHALL BE GLASS P; SHALL HAVE A MINIMUM 40% POWER FACTOR; SOUND LEVELS SHALL NOT EXCEED CLASS A AMBIENT NOISE LEVELS; AND SHALL BE LOW HEAT TYPE. ALL BALLASTS SHALL BE BY ADVANCE. BALLASTS FOR 36W through 5511 LAMPS SHALL BE MARK V ELECTRONIC TYPE. I6A6 MISCELLANEOUS ELECTRICAL ISA 6-1 WIRING OF MECHANICAL EQUIPMENT. FURNISH AND INSTALL ALL POWER WIRING, AND ALL CONTROL AND INTERLOCK WIRING OF ALL UNITS, PUMPS, FANS, WATER HEATERS, DOOR OPERATORS, ETC. CONNECT PER MANUFACTURER'S WIRING DIAGRAMS. FURNISH AND INSTALL ALL DISCONNECT SWITCHES AS REQUIRED. AFTER INSTALLATION OF THE CONTROL INTERLOCK WIRING, THE CONTRACTOR SHALL VERIFY THAT EACH MOTOR LOAD HAS THE CORRECT PHASE ROTATION. THIS CONTRACTOR SHALL VERIFY THE ACTUAL WIRE SIZING AMPS FOR MECHANICAL EQUIPMENT FROM THE EQUIPMENT NAMEPLATE; ELECTRICAL INSTALLATION SHALL BE BASED ON ACTUAL REQUIRED AMPERAGES, WHICH MAY VARY SOMEWHAT FROM THE WIRE AND EQUIPMENT SIZES SHOWN 014 THE DRAWINGS. PROPERLY SIZED ELECTRICAL WIRING AND EQUIPMENT SHALL BE FURNISHED WITHOUT EXTRA COST TO THE CONTRACT. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ALL CHANGES TO BE MADE IN THE ELECTRICAL INSTALLATION DUE TO EQUIPMENT VARIANCES 50 THAT THE IMPACT ON FEEDERS, PANELS, FUSE AND BREAKER SIZES GAN BE CHECKED PRIOR TO THE INSTALLATION. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING WITH THE MECHANICAL, REFRIGERATION AND PLUMBING CONTRACTORS TO VERIFY THE ACTUAL WIRE SIZING AMPS AND CORRECT SIZES OF ALL OVERLOAD HEATERS FOR ALL EQUIPMENT. )6A 6-2 WIRING OF THERMOSTATS AND TEMPERATURE CONTROLS FURNISH AND INSTALL ALL POWER WIRING, AND ALL CONTROL AND INTERLOCK WIRING OF ALL THERMOSTATS AND TEMPERATURE CONTROL DEVICES INCLUDING NIGHTSTATS, TIME SNITCHES AND OVERRIDE TIMERS, ETC., NOT INSTALLED UNDER PREVIOUS CONTRACT AND SHOWN ON MECHANICAL DRAWINGS SUBMITTED UNDER THIS CONTRACT. SEE MECHANICAL DRAWINGS FOR LOCATIONS AND TEMPERATURE CONTROL DIAGRAMS. 16A 6-3 TELEPHONE SYSTEM PROVISIONS. PROVIDE AND INSTALL INCOMING TELEPHONE SERVICE CONDUIT AS SHOWN 014 DRAWINGS OR A5 REQUIRED BY TELEPHONE COMPANY. PROVIDE AND INSTALL PLYWOOD BOARD IN EQUIPMENT CLOSET FOR TELEPHONE, SECURITY AND AUDIO/VISUAL EQUIPMENT AT LOCATION A5 SHOWN ON DRAWINGS. PROVIDE AND INSTALL FLUSH MOUNTED TELEPHONE OUTLET BOXES WITH 3/4" CONDUIT CONGEALED ABOVE ACCESSIBLE CEILING SPACE AT LOCATIONS AS SHOWN 014 DRAWINGS. TELEPHONE COMPANY TO INSTALL TELEPHONE JACKS AND WIRING. ISA 6-4 DATA. TV AND SECURITY SYSTEM PROVISIONS. TELEPHONE, DATA AND SECURITY CONDUITS SHALL BE A MINIMUM OF TWO GANG BOX WITH SINGLE` GANG PLASTER RING. PROVIDE BUSHED HOLE OR GOVERFLATE WITH COAXIAL OPENINGS A5 DIRECTED BY OWNER. PROVIDE CONDUIT AND PULLWIRE FOR COMPUTER/DATA EQUIPMENT A5 DIRECTED ON DRAWINGS (WIRE, JACKS AND FINAL CONNECTION BY OTHERS). PROVIDE CONDUIT AND PULLWIRE FOR SECURITY EQUIPMENT (EQUIPMENT SUPPLIED AND INSTALLED BY OTHERS). ISA 6-5 CONTACTORS. INSTALL OWNER FURNISHED MECHANICALLY HELD CONTACTOR DESIGNED FOR TUNGSTEN AND BALLAST LIGHTING LOADS. 16A8 EXISTING EQUIPMENT REUSE AND REMOVAL. THIS CONTRACTOR SHALL REMOVE ALL EXISTING WIRING, FIXTURES, EXPOSED CONDUITS AND OTHER ELECTRICAL INSTALLATIONS NOT REUSED PRIOR TO TERMINATION OF THE WORK. EXISTING CONDUITS AND RACEWAYS MAY BE REUSED IF THEIR POINTS OF TERMINATIONS ARE SUITABLE; IF THEY ARE CLEAN INSIDE WITH NO EVIDENCE OF RUST OR BURRS; IF FREE FROM CRACKS, FLATTENED SECTIONS OR SHARP BENDS; AND IF SUITABLY LOCATED TO AVOID CONFLICTS WITH OTHER TRADES OR INSTALLATIONS. ALL EXISTING CONDUITS REUSED UNDER THIS CONTRACT SHALL BE CAREFULLY "P15HE17" TO REMOVE ALL DEBRIS AND OBSTRUCTIONS, AND SWABBED UNTIL ALL MOISTURE 15 REMOVED. IT SHALL BE THE RESPONSIBILITY OF THI5 CONTRACTOR TO CUT, PATCH, AND REPAIR WHERE REQUIRED FOR NEW ELECTRICAL INSTALLATIONS, AND 14E SHALL PATCH AND REPAIR ANY SURFACE DAMAGE RESULTING FROM 1415 WORK. CONDUITS STUBBED ABOVE THE FLOOR AND NOT USED AT THE TERMINATION OF THE WORK SHALL BE CUT FLUSH WITH THE FLOOR AND PLUGGED AT BOTH 514175. ALL EXISTING ELECTRICAL SYSTEMS REQUIRED TO BE IN OPERATION AT THE TERMINATION OF THE CONTRACT SHALL BE RELOCATED, IF REQUIRED, A5 A RESULT OF WORK INCLUDED UNDER THIS CONTRACT, EVEN IF NOT SPECIFICALLY INDICATED IN THE DRAWINGS OR SPECIFICATIONS. REFER TO LANDLORD'S MECHANICAL/ELECTRICAL CRITERIA FOR ADDITIONAL SCOPE OF WORK TO BE INCLUDED UNDER THIS CONTRACT. t1( 3-q)47 #644 Westfield South Center Seattle, WA #204 Th ° 'It,: 1,647 13064 1LI,,. RECEIVED CITY OF TUKWILA MAY 3 0 2013 PERMIT CENTER 1, mlnimmimmul '9869 REGI AR JIMMY L. POW' RS STATE OF WAS INGTON pl E.4