Loading...
HomeMy WebLinkAboutPermit PG13-100 - BOEING #9-53 - ALTERATIONBOEING #9-53 9725 EAST MARGINAL wYs PG13-100 Parcel No.: Address: City of Ikkwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT 0003400018 9725 EAST MARGINAL WY S TUKW Project Name: BOEING #9-53 Permit Number: Issue Date: Permit Expires On: PG13-100 08/02/2013 01/29/2014 Owner: Name: Address: Contact Person: Name: Address: Email: BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 98124 MARGIE DE LEON PO BOX 249 , AUBURN WA 98071 MARGIEDELEON@AUBURNMECHANICAL. C OM Contractor: Name: AUBURN MECHANICAL INC Address: PO BOX 249 , AUBURN, WA 98071 Contractor License No: AUBURMI163BA Phone: 253 838-9780 Phone: (253)838-9780 Expiration Date: 09/12/2014 DESCRIPTION OF WORK: (3) WATER CONNECTIONS FOR HUMIDIFIERS AND (3) CONDENSATE DRAINS FOR CRAC UNITS (SEE M13-131) Value of Plumbing/Gas Piping: Fees Collected: Electrical Service Provided by: $325,562.00 $145.63 Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie exami: with, Uniform Plumbing Code Edition: 2009 International Fuel Gas Code Edition: 2009 Date: ied this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not press a to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this plumbing/gas piping permit and agree to the conditions on the back of this permit. Signature: Print Name: !J&/ 5b1 fry This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: -Z.-- 1013 ..S,.. 1 Iter A/1n or-i•ti nn Printerl• OR -09-7013 • PERMIT CONDITIONS Permit No. PG 13-100 1: ***PLUMBING AND GAS PIPING*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. doc: UPC -4/10 PG13-100 Printed: 08-02-2013 CITY OF TUK Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://vvww.TukwilaWA.gov • Plumbing/Gas Permit No. p(,-irb-`00 Project No. Date Application Accepted: Date Application Expires: (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 1-S3 King Co Assessor's Tax No.: 56242009900 Site Address: 9725 East Marginal Way S.,Tukwila,WA 98108 Suite Number: Floor: 1 Tenant Name: Boeing Commercial Airplane Group PROPERTY OWNER Name: Margie De Leon Name: The Boeing Company Address: P.O. Box 249 Address: 9905 E Marginal Way S City: Auburn State: WA City: Tukwila State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Margie De Leon Address: P.O> Box 249 Address: P.O. Box 249 Phone: (253) 838-9780 Fax: (253) 833-1384 City: Auburn State: WA Zip: 98071 Phone: (253) 838-9780 Fax: (253) 833-1384 Email: margiedeleon@auburnmechanical.com New Tenant: ❑ Yes 11..No PLUMBING CONTRACTOR INFORMATION Company Name: Auburn Mechanical Address: P.O> Box 249 City: Auburn State: WA Zip: 98071 Phone: (253) 838-9780 Fax: (253) 833-1384 Contr Reg No.: AU -BU -RM -I163 Exp Date: 09/12/2014 Tukwila Business License No.: BUS -0100148 Valuation of Project (contractor's bid price): $ 325,562 Scope of Work (please provide detailed information): (3) Water connections for humidifiers and (3) condensate drains for CRAC units. Building Use (per Int'l Building Code). Occupancy (per Int'1 Building Code): Group BI Business Utility Purveyor: Water- Not listed on Parcel Viewer H:\Applications\Fomu-Applications On Line \20I I Applications \Plumbing Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Sewer. Not listed on Parcel Viewer Page 1 of 2 Indicate type of plumbing fixtures and/o as piping outlets being installed and the quantit poelow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) 3 Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment 3 Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping 3 Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature: R OR AUTHO'k ED GENT: Date: 7/97//, Print Name: Mar e De Leon Day Telephone: (253) 838-9780 Mailing Address: P.O. Box 249 H:\ Applications\ Forms -Applications On Lme\2011 Applications \Plumbing Permit Application Revised 8-9-11.docx Revised: August 2011 bh Auburn WA 98071 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 0003400018 Permit Number: PG13-100 Address: 9725 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 07/15/2013 Applicant: BOEING #9-53 Issue Date: Receipt No.: R13-02278 Initials: User ID: JEM 1165 Payment Amount: $116.50 Payment Date: 08/02/2013 10:31 AM Balance: $0.00 Payee: AUBURN MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0011735 116.50 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLUMBING - NONRES 000.322.103.00.00 116.50 Total: $116.50 Printed• 08-02-2013 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 0003400018 Permit Number: PG13-100 Address: 9725 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 07/15/2013 Applicant: BOEING #9-53 Issue Date: Receipt No.: R13-02130 Initials: JEM User ID: 1165 Payment Amount: $29.13 Payment Date: 07/15/2013 12:40 PM Balance: $116.50 Payee: AUBURN MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0011721 29.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 29.13 Total: $29.13 Drinrcrd• f17_1 c_9n1 INSPECTION RECORD Retain a copy with permit PG 13 -1 �o INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proj `o���� g—�3 Type_oInspectio '��v�� A(Li,�13r Address: `r 7 7S E„M AJ6,:A 4 Date Called: (___ ---, Special Instructions: j Date Wanted: 10 -23 -i `ate p.. Requester: Phon _36 — 0, 5 61 Approvedper applicable codes. ElCorrections required prior to approval. COMMENTS: por; i c MP Inspqttor: Date: /) t,�23't REINSPECTION FEE REQUIior to next inspection, fee must be paid at 6300 Southcenter Bl d.. Suite 100. Call to schedule reinspection. INSPEC ISN NO. INSPECTION RECORD Retain a copy with permit p�i$-io0 PERMIT. NO. CITY OF TUKWILA BUILDING DIVISION G 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ULA . (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: f .-e_,Ac9 c" -S; Type of Inspection: 83060- .A n1t (J P �, Address:- 9'1 ; , ANc,.Ail 25 Date Called: rio 4toi„5-1e _, Special Instructions:. • Date Wanted: q.._ 'n W 7 13 CMM p.m. Requester: _ \) Phone No: Q U Q [Approvedper applicable codes. Ij Corrections required prior to approval. COMMENTS: - rio 4toi„5-1e v 1 t f /<0 J ,� _ \) �,� U _ t - • Inspector: Date nI REINSPECTION FEE'REQUIR D. Prior to next inspection. fee must be 4paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. THE AFWEZNC COMPANY SUPPORT SERVICES GROUP . 3 BUILDING - INTEGRATED TECHNICAL Permit o. DEVELOPMENT LAB BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH _ _ _•. TUKWILA, WASHINGTON 98 Plh rry►L,nr approval is subject to errors and omissions. Of construction documents does not authorize t 1.•q of fwpi,/rov B Date: ir3 A¢ r City Of Tkikwila BUILDING 0 SEVARATE PERMIT FROM DOWNTO N sN-EQU I RET-/ FOR: echanical Iectrical ❑umbing r jssPiping FlTukwila DIVISION CODE SUMMARY TYPE OF APPLICATION: NEW 0 ALTERATION ❑ ADDITION❑ TENANT IMPROVEMENT • PROJECT DESCRIPTION: UPGRADES OF EXISTING HVAC, POWER, AND FIRE PROTECTION FOR THE INTEGRATED TECHNICAL DEVELOPMENT LAB AREA 1) PROVISION OF TWO COMPUTER ROOM UNITS WITH DIRECT EXPANSION COOLING COIL, ELECTRIC OWNER PROVIDED IT UPGRADES. 4) UPGRADES OF THE FIRE DETECTION AND FIRE SUPPRESSION SYSTEMS SERVING THE SPACE. 5) PROVISION OF AN AIR DAM IN UNDERFLOOR SPACE. 6) PROVISION OF CONCRETE PAD FOR OUTDOOR MECHANICAL EQUIPMENT . CODES: 2009 INTERNATIONAL BUILDING CODE & WAC 51-50 2009 INTERNATIONAL MECHANICAL CODE & WAC 51-52 2009 INTERNATIONAL FlRE CODE & WAC 51-54 CURRENT WASHINGTON STATE ENERGY CODE WAC 51-11 CURRENT CITY OF TUKWILA ZONING ORDINANCES CONTRACTOR & STATE NUMBER: THE BOEING CO. BOEINC * 294ML(0V2009) BOEING PROJECT ENGINEER- THOMAS HANSON, AIA AT 206-947-4880 BOEING CONTACT: JOHNMURDOCH PHONE. 253-773-0444 FAX NUMBER- 253-773-0119 E-MAIL (ohn.s.murdochOboeinq.com ZONING: OCCUPANCY GROUP: GROUP BI BUSINESS CONSTRUCTION TYPE. TYPE II -B ALLOWABLE AREA INCREASE- SPRINKLERED & 60' SFT -BACK (NO CHANGES) OCCUPANT LOAD: (ALLOWABLE) NO CHANGE FLOOR AREA (ACTUAL) NO CHANGE 99 \ice WAY 599 TUKWILA FROM KENT & AUBURN REVISIONS No ehismgescahSgbe made to the scope of t"itha:: prior approval of i_ ii'• 1 i " ..... A51�Eiii.° se tvi ER 1 + a(new pan submittal n-/ �in..•ude additional plan review fees sw RENSIN SCALE SYN REVSEN (TABLE 10-A) OFFICES OCC BLDG GROSS 97.901 SF so ET STORAGE OCC TUNNEL SD FT LABORATORY OCC FIRST FLOOR 54.821 SF SO FT CANOPY OCC 1ST FLR MEZZ 50 11 OTHER OCC 2ND FLOOR 43,080 SF so FT 2ND FLOOR ME77 - SO FT PROJECT AREA 151 FLR 1454 SF SO FT BUILDING HEIGHT: (ACTUAL) 44 FT STORIES: 2 MEZZANINE 7 0 (YES) • (NO) FIRE PROTECTION: SPRINKLERED THROUGHOUT PER NFPA 13 SO FT II (YES) 0 (NO) SEPARATION EXTERIOR WALL (NON-BEARING) HOUR RATING EXTTERIOR WALL (BEARING) HOUR RATING INTERIOR WALL (NON-BEARING) HOUR RATING INTERIOR WALL (BEARING) HOUR RATING DEMOUNTABLE PARTMONS HOUR RATING STRUCTURAL FRAME HOUR RATING FLOOR/CEIUNGS HOUR RATING ROOF CONSTRUCTION HOUR RATING SEISMIC DESIGN: ZONE b' DESIGN LOADS: (CHAPTER 16) ROOF: LIVE (SNOW) (PSF) FLOOR : OFFICE (PSF) MECH/STOR (PSF) STAIRS (PSF) CONCENTRATED: VEND: EXPOSURE 80 MPH. EXPOSURE C A B C D •ASF VIRTUAL REAL TRNNING AREA D1S - INSTALL WALLS FOR UCAV NEW WARFARE OFFICE 4784654-00 4523331-08 4120573-00 6101 GMM 1149 10.06.98 09.10.02 1.7.03 K WALL REMOVAL MOOS INSTALL SUSPENDED CEILINGS F-22/CTM ROOM MODS NCO LAB TO 9-53 4120110-00 1149 08.12.03 M DEVELOPMENT LAB - IFC 149-12058 9-53.2 F-22 TRNNING AREA 5118 1149 10.07.09 DRAWING INDEX ARCHITECTURAL DRAWING NUMBER REV DRAWING TITLE 09-53-G1 N TITLE SHEET •9-53-1A01 N FLOOR PLAN 09 • -1A13R G REMOVAL FLOOR PLAN 09-53- 4R H REMOVAL FLOOR PLAN 09-53-1A1 J FLOOR PLAN 09-53-1M4 H FLOOR PLAN 09-53-1A283 G REFLECTED CEILING 'o• 09-53-A506 F DETAILS 09-53-A507 DETAILS S 'QCT' L DRAWING NUMBER REV D'• .G TITLE 09-53.1-1563 C FIRST FLOOR SLAB PLAN 09-53.1-1 C FIRST FLOOR SLAB PLAN 09-53 520 C SECTIONS AND DETAILS MECHANICAL DRAWING NUMBER REV DRAWING TITLE 09-53.1-1M13R L FIRST FLOOR HVAC PLAN - NORTH 09-53.1-1M14R F FIRST FLOOR HVAC PLAN - SOUTH 09-53.1-M1 B HVAC LEGEND 09-53.1-M1A B PIPING LEGEND 09-53.1-M2 B MECHANICAL GENERAL NOTES 09-53.1-1M13 L FIRST FLOOR HVAC PLAN - NORTH 0•- 31-1 .4 Iitil FR F OIR • •1.1 G P - SI H 19- - 1 1'S •0' •L : - 1' 09-53.1-1M114 H FIRST FLOOR PLUMBING PLAN - SOUTH 09-53.1-M311 C DETAILS - MECHANICAL 09-53.1-M360 F SCHEDULES 09-53.1-M361 G SCHEDULES 09-53.1-M450 E ENLARGED PLAN 09-53.1-M451 C MECHANICAL SECTION 09-53.1-M506 D .. E5 rEVICw FOR - CODE COMPLIANCE APPROVED JUL 2013 29 n/City 0- Cityof Tukwila BUILDING DIVISION 41067207 112125341 #12337259 TWH 1149 1WH 06.24.10 09.08.11 DEVELOPMENT LAB - ECN-OI WH_12058 9-12061 07.24.12 OLATAFEFAVG ° ACCEPTAB UTY 1Na 060x! N°/OR SPEGf1CA110N 6 APV0.0+ID 0 0 CODES AND PERMITS PROJECE TIRE F-22/CRUS ROOM MODS JOB NUMBER: /12337259 QUANTITY SUBMITTED - O 5 SETS: GENERAL PERMD (SHELL & CORE) OR STRUCTURAL TENANT IMPROVEMENT II 4 SETS TENANT IMPROVEMENT (NON-STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION/SPRINKLERS ❑ 2 SETS: TENANT IMPROVEMENT (RMSION) SUBMITTED FOR PERMIT & REVIEW PORING ❑ GRADING PLUMBING TIF 0 LANDSCAPE ❑ MECHANICAL * 0 001401DON ❑ STRUCTURAL ❑ - ❑ ELECTRICAL •IE ❑ FIRE PROTECTION * ❑ CANTILEVER RACKS ❑ - TIF TO BE REVIEWED UNDER SEPARATE PERMB WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE -APPROACHES COMPLIANCE OPTION • PRESCRIPTIVE 0 LPA 0 ANALYSIS SPECIAL INSPECTIONS REQUIRED: ❑ WELD ❑ REBAR ❑ STRUCTURAL BOLTING ❑ OTHER CALCULATIONS N/A TYPE: 0 N/A ❑ CONCRETE ❑ ANCHOR BOLTS ❑ STRUCTURAL OBSERVATION ATTACHED -(YES) -040) DRAWING INDEX ELECTRICAL DRA G NUMBER DRAWING TITLE 09-D 3-1 9- 09-053-1E11 09-053-1E2 09-053-1E514 F E B E G N LAN S L•1. 4:0 PARTIAL 1ST FLOOR 480Y/27 1ST FLOOR 480/270 POWE DEV LAB ENLARGED 480V o A� REMOVAL PLAN PLAN OWER PLAN 0 -1 3-E 1 w l N;,. CD 21 -I FS.; ' C E •t*�r•.i9a•t�trrr oi•sa ry»ms•nra,mp-a,,t..0 1.a. 0 -1 3-E 5:1L,Jve!liler P & 8 F• 7.1 DRAWING NUMBER 9-53.1-1E263 9-53.1-E531 9-53.1 -E532 9-53.1-E533 9-53.1-E534 9-53.1-E535 9-53.1-E536 9-53.1-E537 9-53.1-E538 FIRE OTECTION 0S REV DRAWING TITLE SMOKE DET TION SYSTEM BILL OF MATE • & NOTES EQUIPMENT LO ON PLAN & DETAILS AIR SAMPLING N • RK VESDA SYSTEM PIPI DETAILS CO2 PIPING DETAILS & OTES SYSTEM WIRING DETAILS SYSTEM WIRING DETAILS SYSTEM SIGNAGE CITY OF TUKWILPNCEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER P613-IoO FOR CONSTRUCTION PROJECT TraE: INTEGRATED TECHNICAL DEVELOPMENT LAB z COVER SHEET . -2 WWW REMON 9-12061 06.20.13 INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53 06.20.13 ARCHITECTURAL MASTER COL. D.C. 12125341 9-53-A1 230 CF TYP (8'NECK) 700 CFM T 1) 15 250 CFM TTP 4 (8"NECK) 750 CFM TYP 1) 1M1311,14451 13 M500 FD 1 [1.1111i I 1112/ =TIM 'ff"11110011,rii: 48/20 la I � 26/12 28/2411 26/16 UP 36/24 UP 26/4 af 16 40/28 (126 141 (1 28/24 270 CFM TYP 16/14 ." • 0/24 FD (CC 400 CFM 180 CFM 700 CFM (TYP 2) ATCHLINE - SEE SHEET 1M14R 150 CF (TYP 10X10 600 CFM 00 CFM 1- 725 CFM TYP H a5 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 .(AA.5 City of Tukwila BUILDING DIVISION (AA RECEIVED (A) 700 CFM 100CFM (TYP 10X8 150 CFM (TYP FIRST FLOOR PLAN — NORTH CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER LEGEND CRAC COMPUTER ROOM AIR CONDITIONING UNIT CW DOMESTIC COLD WATER GENERAL NOTES 1. SOUND -LINE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON SHEET M3. SECURE PENETRATION. SEE DETAIL [i SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. I5> SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. TYP M501 TYP I M501 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 7. GENERAL NOTES ON SHEET 142 SHALL APPLY. REFERENCE DRAWINGS CIN TR C ON NeTE 12> REMOVE EXISTING DIFFUSERS, GRILLES, AND TERMINAL UNIT, CONTROLS AND ASSOCIATED DUCTWORK. CAP DUCTWORK AT THE BRANCH TAKE -OFF. PROVIDE NEW CEILING TILES 10 MATCH THE EXISTING AT LOCATIONS WHERE DIFFUSERS AND GRILLES ARE REMOVED. REMOVAL FOR CONSTRUCTION m j 00615002040 CP •nu••u•uirm MUMMILVIKINE mliounnwinimmmm NOM L!11....�11�r .,.____ .... KEY PLAN NOT TO SUE 8 4 0 2 4 16 _ I SCALE: 1/8' = 1'-0' 4 5YM REN50N BY APPROVED DA1E sYM 05 APPROVED K DEVELOPOENT LAB - IFC WH_12058 WH GV 04 01 13 F ADD DETAIL 1/10451 9686868 HARR L DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WH CEL 06 70 13 C MODIFY BR&T COMPUTING LAB 10697207 O.WONC RWS C RECORD DRAWING MJC KMR/RB 8 3091 H INSTL DROPPED CEIUNCS RMS 12883 & 11144 10428-10 HARR D REFEED 4 EXIST. DIFF. 0 CC -5.5 E RELOC NCO LAB 170051 RAD 12011000 RWS RWS 1 DEVELOPMENT LAB - 501 IFR W11_12058 WH GV RWS 08.27.03 J DEVELOPMENT LAB - 901 IFR WH_12058 WH CV DATE 01/27/10 06.1710 09/07/11 06.22.12 07.12.12 gLinswzAvce ACCEPTABILITY L DEWALT THIS DESIGN AND/OR CHLCKED SPECIF1CADON IS APPROVED D. MEYER 'LNLWLfN APPROVED BY DEPT. DATE D. MEYER NECKED K RAMSSEY APPROVED K. RAMSEY LAP ##WovED SUBTITLE FIRST FLOOR HVAC PLAN - NORTH INTEGRATED TECHNICAL DEVELOPMENT LAB 5.17.90 MECHANICAL MASTER BUILDING 9-53.1 COL. A-CC/1-6 CURRENT REM50N SMBOL 9-12061 s0EET 1M13R DATE 06.20.13 JOB N0. DEV. CENTER, WA mvs No. 89065 NNP NO. 9-53 1-1M13R Co 03 iG 26/14 UP 36/24 UP 14/8 14/12 1211 14/12 150 CFM (TYP 40/24 124/24 VO 14 14 SEE DUCT TRANSFER 12/16 DETAIL 1M14 M501 18/14 UP 11251 12C LAB 22/18 UP 290 CFM TYP 1 ` 26 CONFEREN CFM /RG (CC EVIEVVED FOR • DEq� PLIANCE APPROVED LEGEND GENERAL NOTES 1. SOUND -LINE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON SHEET M3. Li SECURE PENETRATION. SEE DETAIL [i SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. M> SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. 501 TYP,M501 TYPO M501 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS 850 CFM (2 TYP) 230 CFM TYP 9 12/16 'JUL 2 9 2013 OFFICE 305 CFM (TYP UT1 CFFI(FS OFFICLN City otTukwila ItDINtblVISION 180 CFM 1 /16" -L 2/i' 3 224P0 CFM TY 11 11 11 11 li II II II 111 1 I I 1I 11 I J = JL- - FIRST FLOOR PLAN - SOUTH CONSTRUCTION NOTES REMOVE EXISTING DIFFUSERS, GRILLES, AND TERMINAL UNIT, CONTROLS AND ASSOCIATED DUCTWORK. CAP DUCTWORK AT THE BRANCH TAKE -OFF. PROVIDE NEW CEIIJNG TILES TO MATCH THE EXISTING AT LOCATIONS WHERE DIFFUSERS AND GRILLES ARE REMOVED. RECEIVED CITY OF TUKW1LA JUL 1 5 2013 PERMIT CENTER REMOVAL FOR CONSTRUCTION STM 87 AFPROYED DALE SYM BY APPROrID DATE A RECORD DRAWING MOVE THERMOSTAT D1321848 MJC SLB KMR/RB MKS 8.30.91 F DEVELOPMENT LAB - IFC WH_12058 811 07.24.12 RELOCATE NCO LAB 12011000 RWS RWS 0828.03 DEVELOPMENT LAB - 50% IFR WH_12058 WH GY 06.22.12 E DEVELOPMENT LAB - 90% IFR W9_12058 WH GV 07.12.12 ce;LAM7E7AW ACCEPTABILITY THIS DESIGN IN0/08 SPECIFICATION IS APPROVED SUBTITLE L. DEWALT CHECKED D. MEYER FIRST FLOOR HVAC PLAN - SOUTH 8 T 000©00 0j KEY PLAN OPT TO SONE 8 4 0 2 4 16 'SCALE: 1/8' = 1'-0" CURRENT REVISION 9-12061 SYMBOL F DME 07.24.12 APPROVED BY DEPT. DATE ENGINLLN W. HENCKEL CHECKED K. RAASEY APPROVED K. RAMSEY APPROVED L LAW 5.17.90 TI1LE INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 COL. A-CC/6-11 DEV. CENTER, WA MECHANICAL MASTER SHEET 1 M 14 R JOB NO. D1321848 COMP NO. DWG N0. 9-53-1M14 VECHA\ICAL HVAC LEGE\3 GENERAL GENERAL ABBREVIATIONS ABBREVIATIONS ABBREVIATIONS GENERAL DESCRIPTION SYMBOL - DESCRIPTION SYMBOL - DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION ABBREVIATION DESCRIPTION SYMBOL ANCHOR HC HEATING COIL TDH TOTAL DYNAMIC HEAD (FEET OF WATER) A TEMP TEMPERATURE 5` 2412 1' RECTANGULAR DUCT, FIRST NUMBER y SUPPLY AIR FLOW DIRECTION, Q TEMPERATURE SENSOR, WALL ?IAV AUTOMATIC AIR VENT HD HEAD - FEET OF WATER TH TOTAL HEAD (FEET OF WATER) 24x12-_ INDICATES SIZE FOR SIDE SHOWN POSITIVE PRESSURE AD ACCESS DOOR ADD ANGULAR DOWN DISCHARGE HORIZ HORIZONTAL HP HORSEPOWER THC TOTAL HEAT CAPICFTY 24113 DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST �� RETURN, OUTSIDE OR EXHAUST AIR FLOW DIRECTION, NEGATIVE PRESSURE THERMOSTAT, WALL AF AIR FOIL WHEEL AFF ABOVE FINISHED FLOOR AMS AIR MEASURING STATION AP ACCESS PANEL HPC HIGH PRESSURE CONDENSATE HR HOUR HVAC HEATING, VENTILATING AND AIR CONDITIONING HPU HEAT PUMP UNIT THD TOP HORIZONTAL DISCHARGE THRD THREADED TOD TOP OF DUCT TOS TOP OF STEEL APPROX APPROXIMATELY HTG HEATING TOP TOP OF PIPE 240 i ROUND DUCT, NUMBER INDICATES Q HUMIDITY SENSOR ARCH ARCHITECTURAL HW DOMESTIC HOT WATER TP TOTAL PRESSURE, TRAP PRIMER Y40DIAMETER AUD ANGULAR UP DISCHARGE Hz HERTZ TS TEMPERATURE SWITCH TOTAL STATIC PRESSURE AVG AVERAGE D NSIDE DIMENSIONS TSP TV TURNING VANE 24120 4 OVAL DUCT, FIRST NUMBER INDICATES © CARBON DIOXIDE SENSOR, WALL BI BACKWARD INCLINED WHEEL GV NLET GUIDE VANE TYP TYPICAL 24x120 2 MAJOR DIAMETER, SECOND NUMBER INDICATES MINOR DIAMETER BDD BACK DRAFT DAMPER NSUL NSULATION i BFP BACKFLOW PREVENTER BHD BOTTOM HORIZONTAL DISCHARGE N NSTAN NCHES NSTANTANEOUSTERMEDIATE V VENT VAV VARIABLE AIR VOLUME SUPPLY AR DUCT, SQUARE OR RECTANGULAR ELBOW FACING TOWARDS OCCUPANCY SENSOR BHP BRAKE HORSE POWER BLDG BUILDING NT NTERMEDIATE VD VOLUME DAMPER VP VELOCITY PRESSURE BOD BOTTOM OF DUCTVERT BOTTOM OF PIPE KW KILOWATT KVA KILOVOLT -AMPERE VERTICAL VTA VENT TO ATMOSPHERE -111113 SUPPLY AR DUCT, SQUARE OR RECTANGULAR ELBOW FACING AWAY s 4° DUCT TYPE SMOKE DETECTOR BOP BOS BOTTOM OF STEEL LAT LEAVING AIR TEMPERATURE ('F) LBS, i POUNDS VTR VENT THROUGH ROOF BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR LVG LEAVING ID INSIDE DIAMETER =ITh, EXHAUST, RETURN OR SUPPLY AIR DUCT © PRESSURE SENSOR BW BUTIWELD LWT LEAVING WATER TEMPERATURE ('F) IE INVERT ELEVATION �L�;'/j ROUND, ELBOW FACING TOWARDS C COMMON MA MIXED AIR . Cv FLOW COEFFICIENT MAX MAXIMUM - • - W WASTE 'C TEMPERATURE - DEGREES CELSIUS _ . MBH BTU PER HOUR X 7000 WET BULB TEMPERATURE WBWG EXHAUST, RETURN OR SUPPLY AIR DUCT © PRESSURE SENSOR HIGH/LOW LIMIT CAP CAPACITY MCC MOTOR CONTROL CENTER WAROUND, ELBOW FACING AWAY w CC COOLING COIL MECH MECHANICAL WCO WATERLL CGAUGE OW MIN MINIMUM WS WET STAND PIPE CCW COUNTER CLOCKWISE ROTATION WSEC WASHINGTON STATE ENERGY CODE 2009 ( XI I / V EXHAUST AR OR RETURN AIR DUCT, SQUARE OR RECTANGULAR, ELBOW DIFFUSER AND GRILLE CALLOUTS CFM CUBIC FEET PER MINUTE CI CAST IRON MOV MOTOR OPERATED VALVE MTD, MTG MOUNTED, MOUNTING WH WATER HEATER WHA WATER HAMMER ARRESTOR FACING TOWARDS CENTER LINE NC NORMALLY CLOSED EXHAUST OR RETURN AR DUCT, CO CLEANOUT NEC NATIONAL ELECTRIC CODE I� 0 SQUARE OR RECTANGULAR, ELBOW SUPPLY GRILLE, MARK SG OMBUSTI COMB COMBUSTION CONN CONNECTION NIC NOT IN CONTRACT NO NORMALLY OPEN / NUMBER FACING AWAY CONT CONTINUED/CONTINUATION NTS NOT TO SCALE TRANSITION RECTANGULAR TO RECTANGULAR SG -200 DESIGN CFM, SEE SCHEDULE FOR DIFFUSER AND GRILLE NECK SIZE,CRAG COTG CLEAN OUT TO GRADE CPLG COUPLING CRU COMPUTER ROOM UNITS NPSH NET POSITIVE SUCTION HEAD OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER TYPICAL COMPUTER ROOM AIR CONDITIONING UNITS OCC OCCUPANCY SENSOR Q HEEL TAP OR LOW LOSS TRANSITION AT TAKE OFF FROM OVAL TO ROUND OR CD -CFM = CEILING SUPPLY DIFFUSER CW DOMESTIC COLD WATER DIRECT ACTING OF OVERFLOW OS&Y OUTSIDE SCREW AND YOKE )r ROUND TO ROUND FSD-CFM = FLOOR SUPPLY DIFFUSER TEMPERATURE OUTSIDE DIAMETER p�� TRANSITION SQUARE OR RECTANGULAR SG -CFM = SUPPLY GRILLE DB DRY BULB DBD DOWN BLAST DISCHARGE OD OVHD OVERHEAD ' ; TO ROUND OR OVAL DEG ' DEGREES DI DUCTILE IRON PBD PARALLEL BLADE DAMPER a PCD PUMPED CONDENSATE DRAIN I N -IN DIA 0 DIAMETER PDI PRESSURE DIFFERENTIAL PRESSURE OE REVIESi FOR 1 W/N VOLUME DAMPER (NOT SHOWN) DLM DELUGE AINA I PDI PLBG. &DRAINAGE INSTITUTE VCD Y DN DOWN PN POST INDICATOR VALVE CODE COMPLIANCE DS DOWNSPOUT PLSPOC DUCT PRESSURE LIMIT SWITCH 1_7uP I DUCT OFFSET UP OR DOWN DW D dBG DEC BELS POINT OF POS POSITION CONNECTION - APPROVED DN DP DRY PIPE PRESS PRESSURE I� I OPPOSED BLADE DAMPER (E) EXISTING EA EXHAUST AIR / EACH PRV PRSSURE REGULATING VALVE PS PRESSURE SWITCH PSIG PRESSURE - POUNDS PER SQUARE INCH, GAUGE JUL . 2 9 2013 EAT ENTER AIR TEMPERATURE ('F) PSV PRESSURE RELIEF (SAFETY) VALVE EDC EVERETT DELIVERY CENTER / RETURN AIR • PARALLEL BLADE DAMPER EEFF LL ELBOW EFFICIENCY RECTRA REC ANGULARNG (CONTROLLER) ELEC ELECTRICAL REF REFERENCE ELEV, EL ELEVATION REV REVISED RH RELATIVE HUMIDITY �,` City of Tukwila 4=4:: VOLUME DAMPER ENT ENTERING RM ROOM BUILDING ESP ' EXTERNAL STATIC PRESSURE ROT ROTATION DIVISION ETP ELECTRONIC TRAP PRIMER EVAP EVAPORATOR RPM REVOLUTIONS PER MINUTE DUCT DAMPER, MOTOR OPERATED EWT ENTERING WATER TEMPERATURE RPBP REDUCED PRESSURE BACKFLOW PREVENTER (ELECTRIC)ROD EXH EXHAUST REOUIRED RTN RETURN EXIST EXISTING ER— BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) EXT EXTERIOR / EXTERNAL 'F FAHRENHEIT SA SUPPLY AIR S FSANARSEWER BDD TEMPERATURE - DEGREES M CUBIC FEET OFAIR, AT STANDARD CONDITIONS AD OR AP F FREEZE STAT FC FORWARD CERRVE WHEEL SG SUPPLY GRILLE ® ACCESS DOOR ACCESS PANEL((AP))OR FD FIRE DAMPER, FLOOR DRAIN FLR FOOR SHC SHF ACITY SENSIBLE HEAT FSENSIBLE HEAT ACTOR RECEIVED SOT SHEET 'i'RECTANGULAR -, DUCT SQUARE ELBOW WITH TURNING VANES FCO FLOOR CLEAOTTOM N OUT FOFOB FACE OF BELONGS SO SCREENED OPENING SOV SOLENOID OPERATED VALVE CITY OF TUKWILA FOIC FURNISHED BY OWNER, INSTALLED BY CONTRACTOR SPEC SPECIFICATION SP STATIC ERS j\ .] -1":1;.\)_ LYL RECTANGULAR DUCT, LONG RADIUS ELBOW FOT FLAT ON TOP FPM FRET PEP OO UTE FPWH FREEZE PROOF WALL HYDRANT FS FLOW SWITCH, FIRE SPRINKLER (WET PIPE) SQ SQUARE SS STAINLESS STEEL STL STEEL JUL 1 5 203 —~ GRILLEFl SIDEWALLD SUPPLY AIR OR REGISTER FEET FV FACE VELOCITY FPM STRUC STRUCTURAL SW SOCKET WELD, SITE WATER • DUCT SUCTION PERMIT CENTER FW FIRE WATER 37 CEILING DIFFUSER GAL GALLONS GPM GALLONS PER MINUTE GALL GALVANIZED GA GAGE, GAUGE B GCO GRADE CLEANOUT FLEXIBLE DUCT FOR CONSTRUCTION CURRENT BENS2 rnBa DATE W Ar9ao+m MIE SW RUMEN *0 APPNV+ED DATE ACCEPTABILITY 0�N" j6x suBrtnc HVAC LEGEND 9-12061 B 07.24.12 SW PENSION - 44 105 DE9DN AND/OR SP006CAI N 5 APPROVED sECRm I 5*001 - DEVELOPMENT LAB - 50% IFR W11_12058 WH WH GV GV 06.22.12 07.12.12 ® C)4•,, G?8• 4xPPao+En e1r om. w1c wuECKM m"INTEGRATED TECHNICAL DEVELOPMENT LABM 1 A DEVELOPMENT LAB - 902 IFR W11_12058 I c B DEVELOPMENT NAB -IFC WFi12056 00 GY 07.24.12g_i_AiPZFEZArG „PPR eoovr BUILDING 9-53.1 JOB N0. s T2osT CONP N0. ��, 1 \.5981 4 -,. I9�«0' °N` "c' .PPB o MECHANICAL' MASTER DEV. CENTER, WA 9-53.1-M1 V ECHA\ICAL PILI\G LEGE\D GENERAL SYMBOL DESCRIPTION —i T -- BREAK IN PIPE CROSSING LINES, NO CONNECTION DIRECTION OF FLOW SLOPE DIRECTION OF SLOPE, DOWN EQUIPMENT. MARK NUMBER if- EXIST EXISTING WORK EXISTING TO BE REMOVED HIDDEN OR BELOW GRADE IN -UNE RECIRCULATING PUMP INSULATED PIPE —®— INSULATED PIPE WITH ELECTRIC HEAT TRACING NEW WORK 4 -POC POINT OF CONNECTION PUMP PIPE IDENTIFICATION SYMBOL DESCRIPTION — A— COMPRESSED AR, PLANT —AR— ARGON GAS — AW— ACID WASTE — C— CONDENSATE RETURN (GRAVITY) — CD— CHEMICAL DRAIN —CF— CHEMICAL FEED —CHWR— CHILLED WATER RETURN —CHWS— CHILLED WATER SUPPLY —CLD— CLEAR WATER DRAIN —CLWR— COOLING WATER RETURN —CLWS— COOLING WATER SUPPLY — CRV— CORROSION RESISTANT VENT — CRW— CORROSION RESISTANT WASTE PIPE IDENTIFICATION SYMBOL DESCRIPTION —PW— PROCESS WATER —RD— ROOF DRAM — RDS— REFRIGERANT DISCHARGE — RHG— REFRIGERANT HOT GAS —RL— REFRIGERANT LIQUID —RS— REFRIGERANT SUCTION (GAS) —RWL— RAIN WATER LEADER —S— SPRINKLER LINE — SAN— SANITARY WASTE ABOVE GRADE OR FLOOR SANITARY WASTE BELOW GRADE OR FLOOR — PCD -- PUMPED CONDENSATE DRAIN — STM— STEAM SUPPLY — SW— SITE WATER — CTFR — COOLING TOWER. FILTER RETURN —TP— TRAP PRIMER FIXTURES SYMBOL DESCRIPTION 0 CIRCULAR WASHFOUNTAIN ❑ DF DRINKING FOUNTAIN a EWc ELECTRIC WATER COOLER EWCH ELECTRIC WATER COOLER FOR HANDICAPPED FD FLOOR DRAIN 0 LAv LAVATORY, ROUND COUNTER MOUNT ® IAV LAVATORY, RECTANGULAR COUNTER OR WALL MOUNT L.owc WATER CLOSET, FLUSH VALVE, WALL HUNG WASTE FITTINGS SYMBOL DESCRIPTION 1/4 BEND --II co CLEAN OUT, EXPOSED —co CLEAN OUT, FLOOR —� wco CLEAN OUT, WALL ❑O FFD FUNNEL FLOOR DRAIN El FUD FUNNEL DRAIN LATERAL =al TRENCH DRAIN 0 WR WASTE RECEPTOR, ROOF �Ic0 WYE AND 1/8 BEND, SHOWN WITH CLEAN OUT • FD FLOOR DRAIN LI FD FLOOR DRAIN ABOVE — CTFS — COOLING TOWER FILTER SUPPLY —V -- VENT — CDWR— CONDENSER WATER RETURN —VAC— VACUUM — CDWS— CONDENSER WATER SUPPLY —VPD— VACUUM PUMP DISCHARGE — CW— DOMESTIC COLD WATER — D— DRAIN —DI— DEIONIZED WATER — DW— DISTILLED WATER — F— FIRE LINE, AHEAD OF ALARM VALVE — FH— FIRE HOSE CABINET PIPING — FOR -- FUEL OIL RETURN — FOS— FUEL OIL SUPPLY PIPE FITTINGS SYMBOL DESCRIPTION _f SOLVENT CEMENT SPRING HANGER —0— UNION, FLANGED UNION, SCREWED WELDED FITTING HOSE KN PIPING SPECIALTIES SYMBOL DESCRIPTION 2 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR 3 WAY CONTROL VALVE W/PNEUMATIC ACTUATOR LA /A AIR DROP - HOSE, SIMPLEX / DUPLEX e/e AIR OUTLET - HARD PIPE, SIMPLEX / DUPLEX ANGLE GLOBE VALVE, ELEVATION / PLAN Io 400 AUTOMATIC FLOW CONTROL VALVE (NUMBER INDICATES GPM) -MV AUTOMATIC AIR VENT (WITH IRAN) BFP BACKFLOW PREVENTER PIPE FITTINGS BALANCE VALVE WITH METERING PORTS SYMBOL DESCRIPTION BELL & SPIGOT —v BUND FLANGE —per BALANCE VALVE W/0 METERING PORTS ef)H/-NDH BALL VALVE, OPEN / CLOSED BUTTERFLY VALVE — � BUSHING u- u EXPANSION JOINT FLANGED FITTING COOUNG COIL CHILLED WATER FLOAT VALVE FLOWMETER, VENTURI TYPE — FOV— FUEL OIL VENT — FW— FILTERED WATER FLEXIBLE PIPE CONNECTION HB HOSE BIBB —II—. FLOWMETER ORIFICE ISOLATION VALVE, OPEN / CLOSE — G— NATURAL GAS —HPC— CONDENSATE, STEAM (HIGH PRESSURE) — HPR— CONDENSATE RETURN (HIGH PRESSURE) — HPS— STEAM SUPPLY (HIGH PRESS, 125-250 PSIG) NFHB HOSE BIBB - NON FREEZE PIPE ANCHOR PIPE CAP SCREWED OR SOLDER JOINT GATE VALVE, OUTSIDE SCREW AND YOKE GATE VALVE, WRH HOSE CONNECTION Tao-/ GLOBE VALVE, OPEN / CLOSED PIPE CAP, WELDED OR GROOVED — HPWS— HEAT PUMP WATER SUPPLY PIPE CROSS —HPWR— HEAT PUMP WATER RETURN — HRS— HEAT RECOVERY SUPPLY - SR PIPE ELBOW, 90' SHORT RADIUS HEATING COIL /S -ANAV LIFT CHECK VALVE MANUAL AIR VENT (WITH IRAN) PIPE ELBOW, 90' LONG RADIUS — HRR— HEAT RECOVERY RETURN — HW— DOMESTIC HOT WATER SUPPLY — HWC— DOMESTIC HOT WATER CIRCULATING — HWR— HEATING WATER RETURN — HWS— HEATING WATER SUPPLY —IA— INSTRUMENT AR — ID— INDIRECT DRAIN —IW — INDUSTRIAL WASTE PIPE ELBOW, REDUCING oG MOTOR OPERATED VALVE NEEDLE VALVE —\ PIPE ELBOW, 45' -o PIPE ELBOW, TURNED UP OR TOWARD PIPE ELBOW, TURNED DOWN OR AWAY NITROGEN DROP NITROGEN OUTLET PETCOCK PIPE GUIDE PIPE HANGER X I Y PIPING MATERIAL CHANGE, X TO Y PIPE PLUG — LN2- LIQUID NITROGEN — LPC— CONDENSATE, STEAM (LOW PRESSURE) --- PIPE REDUCER CONCENTRIC �+L�K PETE'S PLUG, WITH BALL VALVE ---Idl— PLUG VALVE/STOP COCK ticoI PRESSURE GAUGE WITH VALVE —4;3— PRESSURE REGULATING VALVE W/EXT PRESS TAP PRESSURE REGULATING VALVE (SELF CONTAINED) �— PIPE REDUCER ECCENTRIC —LPG— LIQUID PETROLEUM GAS — LPS— STEAM SUPPLY (LOW PRESS, 0-15 PSIG) PIPE SUPPORT PRESSURE RELIEF VALVE / SAFETY VALVE -- - QUICK OPENING VALVE PIPE TEE, STRAIGHT — MPC— CONDENSATE, STEAM (MEDIUM PRESSURE) — MPS— STEAM SUPPLY (MEDIUM PRESS, 15-125 PSIG) — OFD— OVERFLOW DRAIN PIPE TEE, UP OR TOWARD r QUICK CLOSING VALVE, FUSIBLE UNK SOLENOID OPERATED VALVE PIPE TEE, DOWN OR AWAY STEAM TRAP H—�- SCREWED FITTING OR AS SPECIFIED — PCWS— PROCESS COOUNG WATER SOURCE — PCWR— PROCESS COOLING WATER RETURN SEISMIC HANGER vA� SEISMIC LOOP —PR— CONDENSATE RETURN (PUMPED) SOLDERED FITTING SWING CHECK VALVE WITH FLOW GAS PRESSURE REGULATOR PIPING SPECIALTIES SYMBOL DESCRIPTION TEST PLUG THERMOMETER, LINE MOUNT THERMOMETER, SEPARABLE WELL MOUNT rn TRAP, FLOAT TRAP SEAL PRIMER VALVE —C=:1 -- UNCLASSIFIED VALVE A VACUUM DROP (LAB VAC) 0 VACUUM OUTLET (LAB VAC) HARD PIPED VACUUM CLEANING OUTLET O VALVE BOX VALVE IN RISER (TYPE SPECIFIED) T WATER HAMMER ARRESTOR WYE STRAINER (WITH DRAIN VALVE) SY1A RENSIW4 - DEVELOPMENT LAB - 500 IFR 0_12058 A DEVELOPMENT LAB - 900 IFR WH_12058 B DEVELOPMENT LOB - IFC WH -12058 B/ APPROVED DATE 5YM BY APPROVED DATE WH GV 06.22.12 WH Gv 07.12.12 WH GV 07.24.12 �eoEs�vo® ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION 15 APPROVED APPROVED BY DEPT. DATE DRAWN CHECKED LNOINLLN CHECKED APPROVED APPROVED DATE WELDING SYMBOL DESCRIPTION ROOT OPENING DEPTH OF FILLING FOR PLUG AND SLOT WELDS EFFECTIVE THROAT CONTOUR SYMBOL FINISH SYMBOL GROOVE ANGLE, /INCLUDED ANGLE OF COUNTERSINK FOR PLUGWEID SIZE OR \ \ A STRENGTH FOR CERTAIN WELDS \ R T>S (E){gi#}L— {I tig} (N) ELEMENTS IN THIS AREA REMAIN AS SHOWN WHEN TAIL AND ARROW ARE REVERSED BAS C WELD SYMBOL OR DETAIL REFERENCE TAIL MAY BE OMMTTTED WHEN REFERENCE IS NOT USED SPECIFICATIONS, PROCESS OR OTHER REFERENCE LENGTH OF WELD PITCH (CENTER TO CENTER SPACING) OF WELDS FIELD WELD SYMBOL ARROW CONNECTING REFERENCE UNE TO ARROW SIDE OR ARROW SIDE MEMBER OF JOINT WELD ALL AROUND SYMBOL REFERENCE UNE NUMBER OF SPOT OR PROJECTION WELDS BACK WELD FILLET WELD PLUG OR SLOT WELD I I SQUARE WELD O SPOT OR PROJECTION WELD REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 2 9 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION SUBTITLE PIPING LEGEND TREE INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 CURRENT REVISION SYMBOL 9-12061 B SHEET DATE 07.24.12 JOB NO. 9-12061 COW NO. VECHA\ICAL- GE\EAL_ \ OTES 1. THE FOLLOWING NOTES APPLY TO ALL MECHANICAL DRAWINGS. ADDITIONAL NOTES MAY BE INDICATED ON INDIVIDUAL DRAWINGS. 2. DRAWINGS INDICATE CONNECTIONS FOR EQUIPMENT TO BE FURNISHED BY THE OWNER OR AS THE WORK OF OTHER TRADES. VERIFY LOCATION OF EQUIPMENT, ROUGH -IN LOCATIONS, AND TYPE OF CONNECTIONS PRIOR TO PREPARATION OF SHOP DRAWINGS OR SUBMITTALS, AND PRIOR TO INSTALLATION OF SERVICE CONNECTIONS. DO NOT INTERFERE WITH ACCESS FOR MAINTENANCE AND REMOVAL OR REPLACEMENT OF EQUIPMENT. 3. COORDINATE THE PHASING AND INSTALLATION OF NEW WORK WITH THE WORK OF ALL OTHER TRADES. BEAR THE TOTAL EXPENSE FOR ANY ADDITIONAL WORK WHICH MAY BE CAUSED BY THE IMPROPER SEQUENCING OF CONSTRUCTION ACTIVITIES. 4. LOCATE MECHANICAL DEVICES (E.G. TEMPERATURE AND HUMIDITY SENSORS. PANELS, SWITHCHES), SO THAT THEY DO NOT CONFLICT WITH GENERAL CONSTRUCTION (E.G. WAINSCOT, DOOR HARDWARE), ELECTRICAL SYSTEM(E.G. LIGHT SWITCHES, SPEAKERS, OUTLETS), AND THE WORK OF OTHER TRADES. 5. REFER TO ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR GENERAL CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, EQUIPMENT HOUSEKEEPING PADS, PENETRATION DETAILS, FLASHING AND SEALING DETAILS, AND OTHER ELEMENTS OF GENERAL CONSTRUCTION. COORDINATE THE SIZE AND LOCATION OF EQUIPMENT HOUSEKEEPING PADS WITH APPROVED EQUIPMENT SO THAT HOUSEKEEPING PADS ARE NOMINALLY 4" HIGH UNLESS INDICATED OTHERWISE, AND EXTEND 6" MINIMUM IN ALL DIRECTIONS FROM THE HORIZONTAL LIMITS OF THE EQUIPMENT WHICH THEY SUPPORT. 6. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF CEILING MOUNTED ITEMS. INSTALL CEILING MOUNTED ITEMS IN THE CENTER OF CEIUNG TILES, IN THE CENTER OF ROOMS, OR WHERE INDICATED ON ARCHITECTURAL DRAWINGS. WHERE LOCATION OF ITEMS ARE NOT INDICATED ON ARCHITECTURAL DRAWINGS, OBTAIN DIRECTION FROM ARCHITECT PRIOR TO ROUGH -IN AND INSTALLATION. 7. COORDINATE EQUIPMENT POWER CONNECTION REQUIREMENTS AND ELECTRICAL CHARACTERISTICS WITH ELECTRICAL DRAWINGS AND CONNECTION REQUIREMENTS. COORDINATE VARIATION IN ELECTRICAL CHARACTERISTICS FROM SCHEDULED VALUES. CHANGES TO ELECTRICAL CHARACTERISTICS (E.G. VOLTAGE, AMPS, HORSEPOWER, ETC.) SHALL BE SUBJECT TO APPROVAL. BEAR THE COST FOR REQUIRED REVISION TO THE ELECTRICAL SCOPE OF WORK CAUSED BY VARIATION FROM THE SCHEDULED REQUIREMENTS. 8. COORDINATE THE LOCATION OF WORK TO PROVIDE CLEARANCES OVER UGHTING FIXTURES AND OTHER CEILING MOUNTED DEVICES AS REQUIRED TO ALLOW FOR REMOVAL AND MAINTENANCE ACCESS. 9. DO NOT RESTRICT ACCESS TO ELECTRICAL CABLE TRAYS. AT A MINIMUM, ALLOW 18" CLEAR ON ONE SIDE OF CABLE TRAYS UP TO AN ELEVATION OF 6" ABOVE THE TOP OF THE CABLE TRAY. MAINTAIN 12" MINIMUM CLEARANCE OVER TOP OF CABLE TRAYS EXCEPT WHERE DUCT, PIPING, OR CONDUIT CROSS PERPENDICULAR TO CABLE TRAY, THIS CLEARANCE MAY BE REDUCED TO 6" OVER A DISTANCE OF NO MORE THAN 36" ALONG THE CABLE TRAY. PROVIDE NO LESS THAN 36" BETWEEN AREAS OF REDUCED CLEARANCE AND MAINTAIN INDICATED ACCESS ON THE SAME SIDE OF THE CABLE TRAY EXCEPT WHERE OTHERWISE APPROVED. DO NOT CONNECT TO CABLE TRAYS, CABLE TRAY SUPPORTS OR CABLE TRAY SEISMIC RESTRAINTS. 10. PROVIDE SUPPORTS AND SEISMIC RESTRAINTS FOR PIPES, DUCTS, AND EQUIPMENT AS SPECIFIED, AS REQUIRED. AND AS SHOWN ON THE DRAWINGS. IF REQUIRED FOR INSTALLATION OF PIPES, DUCTS, AND EQUIPMENT, DESIGN AND PROVIDE ADDITIONAL STRUCTURAL MEMBERS BETWEEN COLUMNS, JOISTS, AND STRUCTURAL FRAME TO MEET SUPPORT AND SEISMIC RESTRAINT REACTIONS (FORCES, MOMENTS, DEFLECTIONS). STRUCTURAL MEMBERS AND ANCHORAGES SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED. SUBMIT STRUCTURAL MEMBER SHOP DRAWINGS AND CALCULATIONS FOR REVIEW. STRUCTURAL MEMBERS, BOLTS, AND WELDS SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS SHOWN ON THE STRUCTURAL DRAWINGS AND INDICATED IN THE SPECIFICATIONS. NO WELDING, BOLTING, OR OTHER MEANS OF ATTACHMENT TO THE STRUCTURAL MEMBERS SHALL BE MADE ON PORTIONS OF STRUCTURAL MEMBERS AT OR NEAR CONNECTIONS BETWEEN STRUCTURAL MEMBERS ON ANY ELEMENTS DESIGNATED IN THE SEISMIC LOAD RESISTING SYSTEMS UNLESS APPROVED BY THE STRUCTURAL ENGINEER. 11. 12. 13. DO NOT CORE DRILL OR DRILL THROUGH BEAMS, COLUMNS OR SHEAR WALLS UNLESS INDICATED ON STRUCTURAL DRAWINGS OR AS APPROVED BY THE STRUCTURAL ENGINEER. PROVIDE PIPE SLEEVES AND PENETRATION SEALS AS REQUIRED FOR THE INSTALLATION OF PIPING SYSTEMS. REFER TO SPECIFICATIONS FOR REQUIREMENTS. COORDINATE THE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES SO THAT IT FITS INTO THE SPACE ALLOTTED. PROVIDE SERVICE ACCESS AND CLEARANCES AS INDICATED ON DRAWINGS, AS REQUIRED BY CODES, AND AS RECOMMENDED BY THE MANUFACTURER FOR THE INSTALLATION, REMOVAL, ENTRY, SERVICING, AND MAINTENANCE OF EQUIPMENT. PRIOR TO INSTALLATION, COORDINATE LAYOUT OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES WITH ALL OTHER TRADES TO AVOID BLOCKING SERVICE OR REPLACEMENT ACCESS FOR NEW AND EXISTING EQUIPMENT AND EQUIPMENT INSTALLED BY OTHERS. 14. DRAWINGS ARE DIAGRAMMATIC AND SHOW APPROXIMATE LOCATIONS OF EQUIPMENT, DUCTWORK, PIPING, AND APPURTENANCES. DRAWINGS DO NOT SHOW REQUIRED TRANSITIONS, OFFSETS, FITTINGS, AND DEVICES. REFER TO DETAILS, DIAGRAMS, AND SPECIFICATIONS FOR REQUIRED SYSTEM APPURTENANCES, CONTROL DEVICES, ETC. INSTALL DEVICES IN ACCORDANCE WITH DEVICE MANUFACTURER RECOMMENDATIONS. CAREFULLY INVESTIGATE ELEMENTS OF CONSTRUCTION THAT COULD AFFECT THE WORK TO BE PERFORMED AND ARRANGE NEW WORK ACCORDINGLY. PREPARE COORDINATION DRAWINGS FOR NEW WORK, WHICH ARE COORDINATED WITH THE APPROVED AND INSTALLED WORK OF OTHER TRADES. PROVIDE REQUIRED OFFSETS, FITTINGS, TRANSITIONS, SUPPORTS AND OTHER APPURTENANCES AS REQUIRED. BEAR THE COST OF RE -WORK THAT IS CAUSED BY FAILURE TO COORDINATE. 15. PROVIDE MAXIMUM HEADROOM AND CLEARANCE BELOW DUCTWORK, PIPING AND EQUIPMENT AND ASSOCIATED SUPPORTS AND RESTRAINTS. UNLESS OTHERWISE INDICATED, INSTALL TIGHT TO STRUCTURAL SYSTEMS ABOVE. WHERE WALL MOUNTED, INSTALL AS CLOSE TO WALL AS POSSIBLE. PROVIDE ADDITIONAL FRTINGS AND OFFSETS AS REQUIRED. 16. REFER TO EQUIPMENT SCHEDULES FOR DESIGN CAPACITIES. SCHEDULED VALUES SHALL BE CONSIDERED DESIGN CAPACITIES. PROVIDE EQUIPMENT WHICH MEETS OR EXCEEDS THE SCHEDULED VALUES. MARK THE CONTRACT DRAWING EQUIPMENT SCHEDULES 'TO INDICATE THE CAPACITY OF THE ACTUAL APPROVED EQUIPMENT PROVIDED AND SUBMIT THIS INFORMATION WITH RECORD DRAWINGS AS PART OF PROJECT CLOSEOUT. 17. TO ENHANCE THE CLARITY OF PLAN DRAWINGS, AND WHERE NOT NECESSARY TO DESCRIBE THE REQUIRED SIZE, INDMDUAL SEGMENTS OF DUCT AND PIPE BETWEEN CONNECTIONS MAY BE SHOWN WITHOUT A SIZE INDICATED. WHERE SIZE IS NOT SHOWN ON PLANS, THAT SEGMENT SHALL BE THE SAME SIZE AS THE NEXT UPSTREAM SEGMENT WITH A SIZE INDICATED. 18. DUCTWORK SERVING INDMDUAL DIFFUSERS AND GRILLES IS GENERALLY NOT SIZED. WHERE NOT INDICATED ON PLAN DRAWINGS, REFER TO SCHEDULES AND DETAILS FOR NECK AND BRANCH DUCT SIZES BASED ON INDICATED AIRFLOW RATE OR NECK SIZE. 19. PROVIDE A MANUAL VOLUME DAMPER FOR EACH SUPPLY GRILLE, IN ALL BRANCH DUCTS WHERE THREE OR MORE OPENINGS ARE ASSOCIATED WITH BRANCH, AND ELSEWHERE AS NOTED ON DRAWINGS OR IN SPECIFICATIONS. LOCATE VOLUME DAMPERS AS FAR AS POSSIBLE FROM OPENINGS. FOR THE PURPOSE OF THIS REQUIREMENT, TERMINAL UNIT PRIMARY AIR DAMPERS ARE CONSIDERED A VOLUME DAMPER. VOLUME DAMPERS ARE NOT REQUIRED FOR CEILING RETURN GRILLES THAT TRANSFER AIR TO A RETURN AIR PLENUM UNLESS OTHERWISE INDICATED. 20. PROVIDE CONICAL TAPS FOR 90 DEGREE ROUND DUCT BRANCHES FROM RECTANGULAR SUPPLY DUCTWORK. DO NOT USE STRAIGHT TEE FITTINGS. 21. DUCTWORK STATIC PRESSURE AND SEAL CLASS, BASED ON SMACNA HDCS: DUCT SYSTEM STATIC PRESSURE A. DOWNSTREAM OF TERMINAL UNITS +1 INCHES WG B. UPSTREAM OF TERMINAL UNITS +10 INCHES WG C. DOWNSTREAM OF COMPUTER ROOM UNITS +1 INCHES WG SEAL CLASS C A C REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER s KITS ON Br APPROVED DATE SYM REVISION B1 APPROVED - DEVELOPMENT LAB - 50% IFR W11_12058 WH CV 06.22.12 A DEVELOPMENT LAB - 90% IFR WH_12058 WH cv 07.12.12 B DEVELOPMENT LAB - IFC WH_12058 WH CY 07.24.12 gi___Arzr,dvc® DRAWN ACCEPTABILITY 1X15 DESIGN MID/OR 401ECRED SPEOOCATON 6 APPROVED SUBTITLE MECHANICAL GENERAL NOTES cuRREM REVISION SYMBOL. 9-12061 B DATE 07.24.12 APPROVED BY DEPT. DATE 000010 D APPROVLD APPROVtD 11RF INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 SKEET JOB NO. M2 9-12061 COMP NO. DEV. CENTER, WA MG0 9-53.1-M2 O 100 CFM (8'NECK) 1M13 1M451 200 CFM FOR ENLARGED PLAN OF THE AREA BELOW LAY -IN CEILING, SEE 350 CFM 26/16 UP 36/24 UP 18113 1M13 M450 26/12 n 6Z!■ n n FOR TERMI INSTALLATIO SEE UNIT DETAIL, 4 26/12 K1 28/24 n 26 14 n 28/24 26/4 270 CFM =i' 10 10 � 40/28 UP 51 1M13 M50 FOR DIFFUSER INSTALLATION 0 SEE • 1 /14 UP 100 CFM 16/20 48/20 400 CFM (B5.5 26/14 150 CF ( TYP 10 600 CFM TCHLINE -.SEE SH 30/14 REVIEWED FOR cppF COMPLIANCE APPROVED JUL 2 9 2013 180 CFM (TYP 5) 700 CFM (TYP 725 CFM Pity of Tukwila DING DIVISION 700 CFM 100CFM (TYP 1088 150 CFM (TYP FIRST FLOOR PLAN - NORTH SW 6EVLSON BY APPR8ED DATE SYE1 6EV6pN 6Y APPROVED 611E K DEVELOPMENT EAB - IFC WH_12058 WH GV 0401.13 F ADD DETAIL 1/16451 9686868 HARR 01/27/10 L DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WH CEL 06.20.13 G MODIFY BR&T COMPUTING LAB 10697207 M.WONG RWS 06.17.10 C RECORD DRAWING 6JC KMR/R8 8.30.91 H IN5TL DROPPED CEIUNGS RMS 12883 & 11904 10428-10 HMR 09/07/11 D REFEED 4 EXIST. DIFF. 0 CC -5.5 170051 RAD NWS I DEVELOPMENT IAB - 500 IFR W11_12058 WH GV , 06.22.12 E RELOC NCO LAB 12011000 RWS RWS 08.27.03 J DEVELOPMENT EAB - 909 IFR W41_12058 WH GV 07.12.12 g)LATAFE,AW ACCEPTABILITY 190 DESIGN AND/OR SPECIFIWKIN IS 90980 ED MANN L DEWALT RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER LEGEND GENERAL NOTES 1. SOUND -UNE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON SHEET M3. SECURE PENETRATION. SEE DETAIL TYPM501 ® SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON. SECURE SIDE OF WALL. I] SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL. TYP I M501 TYP I M501 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. ® FOR TERMINAL UNIT DIAGRAM, SEE 1M13 M311 REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE LOW LEAKAGE CONTROL DAMPER. THE DAMPER SHALL BE CONTROLLED BY THE DDC SYSTEM. CAP EXISTING COLD AND HOT AIR DUCTS. RE -CALIBRATE EXISTING TERMINAL UNIT AND ADJUS AIRFLOW SETPOINT TO 200 CFM. RE -BALANCE EXISTING DIFFUSER AND GRILLES TO INDICATED AIRFLOW. a1 DO 0 0 0 54 0 0 0 00 0 1 11111111 11111111 uII■■■yci,■ MI■IIIIINIMI•I■■°Mall= •iiu•u•uuur� .uI-----..-E Einvirassu FOR CONSTRUCTION CHECKED D. MEYER SUBDRE FIRST FLOOR HVAC PLAN - NORTH APPROVED 6Y DEPT. DATE ENLWEEH D. MEYER KED KK.RRAMSEY K RAMSEY OVED LAPPPROW ED 5.17 90 T'"E INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 COL. A-CC/1-6 DEV. CENTER, WA KEY PLAN NOT 10 SW 8 4 0 2 4 61 16 SCALE: 1/8' = 1'-0" CURRENT 6EMSKl6 9-12061 SHEET JOB N0. ONG NO. SYMBOL L 1M13 DATE 06.20.13 9-53.1-18113 0.3 26/14 UP 36/24 UP 22 14/8 14 12 14 10 12 36/24 4 20 E7 24/14 C)118L14 RL -1- 14/12 230 CFM (TYP 3) 10x8 0 150 CFM ©(TW SEE TRANSFER DUCT DETAIL 1M14 12/16 M501 18/14 UP 14/14 40/24 FOR ENLARGED PLAN OF THE7AREA BELOWLAY—IN CEILING, SEE 1M14 M450 2C LAB 22/18 UP 18/8 290 CFM 200 CFM 600 CFM (6 TYP) YP 600 CFM (BL.5 230 CFM (TYP 9 OFFICE 10/10 305 CFM (TYP 195 CFM UT1 OFFI ES OFFICL ' '`6 II TYP A k 305 CFM p 180 CFM TYP CFM FIRST FLOOR PLAN - SOUTH 11 11 11 II II I1 II II __—JI IL JI 11. (BB (AA (A) LEGEND GENERAL NOTES 1. SOUND—UNE ALL RECTANGULAR DUCTWORK. DUCT DIMENSIONS SHOWN ARE NET INSIDE DIMENSIONS. 2. DISCHARGE DUCTS FROM VAV TERMINAL UNITS TO BE SIZED PER SCHEDULE ON SHEET M3. SECURE PENETRATION. SEE DETAIL [i SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE SIDE OF WALL SECURE PENETRATION. SEE DETAIL FLAG NOTE SYMBOL SHOWN ON SECURE OF .•LL TYP M501 TYPM501 TYP I M501 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION KEY PLAN NOT 10 Scor 8 4 0 2 4 16 SCALE 1/8" = 1'-0" A RECORD DRAWING BY MJC APPROVED 001E 1000 REVISER BY uwawm DATE KMR/RB 8.30.91 F DEVELOPMENT LAB — IFC WH_12058 WH GV 07.24.12 MOVE THERMOSTAT D1321848 SLB RWS RELOCATE NCO LAB 12011000 RWS RWS 08.28.03 D DEVELOPMENT LAB — 50% IFR W9_12058 WH GV 06.22.12 E DEVELOPMENT LAB — 90R IFR WH_12058 W11 GV 07.12.12 BOE/AW ACCEPTABILITY 100 DESIGN AND/OR SPECIFICATION 6 APPROVED WN L. DEWALT CHECKED D. MEYER SUBRRE FIRST FLOOR HVAC PLAN - SOUTH CURRENT REVISION 9-12061 SYMBOL F OTE 07.24.12 APPROVED 8Y DEPT. DATE 00.WEEH W. HENCKEL CHECKED K. RAMSEY APPROVED K. RAMSEY APPROVLD L LAW 5.17.90 PILE INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 COL. A—CC/6-11 DEV. CENTER, WA 1M14 JOB N0. D1321848 COMP NO. DWG NO. 9-53-1M14 cnmorcc. m/ro/m 1073 1121 EXIT VESTIBI{LE I I I 0 0 0 0 00 ( MHO Int X 6"CHWS UP 2° 11 4" H 2" SIT T, F1 1 125 1 UT2C LAB EARTHQUAKE BRACING (TYP) )( 4" CHWSR 2 1/2" __ 11261 CONFERENCE 3' 1 I UT1H MIC ROOM UT9 CONFERENCE ROOM L LAB J LAB I II II II 11 11 11 11 11 11 1JI 11 JL_ .. 8"CHWS EXISTING FIRST FLOOR PLAN — SOUTH 1/8"=1'-0" CC (BB GENERAL NOTES [> CONNECT TO EXISTING 8"CHWS AT FLANGE W.> PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION. FOR SHIELDING SEE SHEET A517. 14 > CR1BB6, 30 TON CHILLED WATER COMPUTER ROOM AIR CONDITIONER, DOWNFLOW, 2 -WAY MODULATING CONTROL VALVE, VARIABLE DRIVE, ICOM CONTROL, 15HP MOTOR, 0.5" SP, ELECTRIC REHEAT, INFRARED HUMIDIFIER. 5 > SEE SHEET M450 FOR CR2BB6 REFRIGERANT PIPING. CONSTRUCTION NOTES REMOVE EXISTING 30 -TON UPFLOW CRU, PACKAGE FOR SHIPMENT, AND DELIVER TO BOEING. CONTACT BOEING CONSTRUCTION MANAGER FOR LOCATION. INSTALL REPLACEMENT DOWN -FLOW CRU FURNISHED BY BOEING REMOVE AND RE -CONNECT EXISTING CHILLED WATER SUPPLY AND RETURN PIPING TO NEW CR1BB6. SEE 1M506 FOR PIPING DETAIL. INSULATE THE CHILLED WATER PIPING WITH 1" THICK FIBERGLASS PIPE INSULATION. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER 0 9) 0000000 Co ,673%%x%/.1"11,■ oteessisrom ■II.■■..■■Iii o MIM11311123EISEIEEMII N O ■■■..■■■■■■MI rL1111==7�7�7!•�a� 7�Oi© I !iIUa�•■■l■r ,. _IL____■■■__ 0 FOR CONSTRUCTION KEY PLAN To SLNE SVM A RELOCATE NCO LAB Br IPPROvED DATE STY 9r APPROVED 120110-00 RWS RYAS 09.02.03 8 DESIGN ACQUIRE/INSTALL 30TON UEBERT 11181858 M.WONC RWS 10.26.10 C DEVELOPMENT LAB - ECN-01 - WH 12058 9-12061 WH ca 06.20.13 prArkwzArc° MEYERDRA CCEPTABILITY L�DDflV� THIS DESON AND/OR D. SPECIFICATION IS APPROVED 2 M wraN APPROVED BY DEPT. DATE W. HENCKEL CHECKED W. HENCKEL APPROVED K. RAMSEY SUBTITLE FIRST FLOOR HVAC PIPING PLAN - SOUTH L LAW TIME INTEGRATED TECHNICAL DEVELOPMENT LAB ' MECHANICAL MASTER BUILDING 9-53.1 COL A-CC/6-11 DEV. CENTER, CURRENT REVISION SYMBOL 9-12061 • IC SHEET1M64 ,roe N0. WA Ow0 N0. 120110-00 9-53-1M64 DATE COMP N0. 06.20.13 0 0 1/2"CW DN THROUGH RAISED FLOOR TILE, SEAL PIPE PENETRATION° AIR TIGHT 1/2"CW TO CR2BB6 CR2BB6, FOR PIPING DIAGRAM, SEE 1M113 M504 C) (1) A 1M11 M500 Y 3/4"CD FROM CR3BB6, FOR CONTINUATION SEE 1M114 1 2"CW TO CR3BB6, FOR CONTINUATION SEE 1M114----'1 3/4"CD FROM COMPUTER ROOM AIR CONDITIONING UNITS 2 -SAN UP TO FD -2 2"ID UP TO FD -2 CC 6 -STS DOWN - SEE DETAIL 1M113M5026"OFD UP I\ 3 > 6"STS UP 3"V UP 3" VENT UNDER RAISED FLOOR 1/2CW" 4 CAP 1"AIR & 2"CW FOR FUTURE PHASES/ 1/2"CW FROM CR1BB6, FOR CONTINUATION SEE 1M114---'""-4 (E)3//4 onr 1-1/2"CD 1"AIR UP 6' DIRT LEI AT BOTTOM 3"CW UP 3/4" CW FD -2A FD -2A 2"V,'-2"SAN UP �? TO FD -2 A C. O. 01FD-2 2'V UP .,"18/4- y'-' JPS 1/2' 2' UP TO FD -2 2"V UP 2"SAN ON 3"2 ID ATCHLINE 2"ID LP TO FD -2 2" SAN 2'SAN UP TO P-6 FOR CONTINUATION SEE SHEET M103 EXPANSION JOINT I - N EARTHOUA�tE BRACING (TVP) 5 X / FIRST FLOOR PLAN - NORTH H IHJ BB.5 3"V DOWN, FOR CONTINUATION SEE SHEET UGM111 (BB REMSIEN A REVISED ID AND SAN SYSTEMS MJC /DM APPRO n KMR /11 SEM APPROVED 6.25.90 DEVELOPMENT LAB — 50% IFR WH_12058 WH 0V 06.22.12 8 R1 1AB REVISION MJC KMR /LL 9.7.90 0 DEVELOPMENT LAB — 900 IFR W4_12058 WH GV 07.12.12 C REVISED FLOOR DRAIN VENTS MJC KMR /LL 9.20.90 H DEVELOPMENT LAB — IFC WH_12058 W11 GV 07.24.12 D MOVED PIPES FROM STAIRWAY MJC KMR /LL 10.25.90 E RECORD DRAWING MJC KMR /RD 8.30.91 ce;LAIWEIAIG. ACCEPTABILITY THIS DESK;N AND/0R SPECR1CA71ON 5 APPROVED APPROVED BY DEPT. DATE REVIEWED FO CODE COMPLIANCE APPROVED 'JUL 2 9 2013 City of Tukwila BUILDING DIVISION (AA (A) RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER u 15> FOR CONSTRUCTION DAN M.CAUNR6 LEGEND GENERAL NOTES PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION; 1' AIR, 3/4"CW. 1" AIR DROP. SEE DETAIL r , TYPjM501 FOR SHIELDING SEE SHEET A517 TERMINATE ROOF OVERFLOW DRAIN ABOUT 2 FT. ABOVE FINISHED GRADE WITH WELDED MITERED ELBOW. PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION. 6. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 7. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES TERMINATE 1-1/2'CD 2" ABOVE BOTTOM OF THE FLOOR SINK. 01 ,L0000 sl 4 71 : tco IIIIIIP%r /.AIME - ■11■■■■■■■i11M -1111111=-11111111..- MItltl♦IEFIEKIESQ®M= MIIIMMIN11111111•11111111111 MIN mennimommmimmon• MIN ENI■■■■■■■■MI KEY PLAN NOT 10 X. 8 4 0 2 4 61 16 SCALE 1/8" = 1.-0" CHECKED D.MEYER SUBTITLE FIRST FLOOR PLUMBING - NORTH LN CURRENT RDASION 9-12061 meal. H DATE 07 24.12 WEEN LN CHECKED K.RAMSEY APPROVED K.RAMSEY APPROVED L LAW 5.17.90 DR INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 COL. A-CC/1-6 DEV. CENTER, WA S ' E' T 1M 1 13 JOB N0. COMP N0. DWG N0. 9-53.1-1M113 1F3 10 ( J ) EXIT VESTIBLLE A FOR PLUMBING 2"SAN DN WCO UNDER OFFICE 1 3 OFFICE THIS AREA SEE SHEET 1M454 0 0 0 0 4- OFFICr ID UP T6 FD -2 UT1 OFFI*ES OFFICE 7 2. UrIILE k_ SAN L_. 2'ID UP TO FD -2 FD -2 H4 2" C.O. 2"SAN UP UT1H MIC R TO P-6 C.O. 2'ID UP TO FD -2 OG 2% ID 27. UT2C LAB 5�C C.O. CR3BB6 FOR PIPING DIAGRAM, SEE 1M114 M504 3/4"CD FROM CR3B66, FOR CONTINUATION, SEE 1M113 1/2"CW TO CR3BB6, FOR CONTINUATION, SEE 1M113 FD -2 • ID 3' 34. lr a 3/4� KA 2% 2' 2"ID UP TO FD -2 UT9 CONFERENCE ROOM C.0 OFFICE 1 JL SAN C.O. 1� ID • FD -2 2"ID UP TO FD -2 r== 1/2'0V ON 1" ID ONFERFN cw FD L LAB 2% 2"ID UP TO FD -2 ID tol z Irc.o. C.O. FIRST FLOOR PLAN — SOUTH SW REW50N BY MPROV1D DATE 5rY Rnsor Br IPPRWW DATE A REVISED ID AND SAN SYSTEMS MJC/DIA KMR/LL 6.25.90 F DEVELOPMENT LAB - 905 IFR W11_12058 WH GV 07.12.12 B RECORD DRAWING 14JC KMR/RB 8.30.91 G DEVELOPMENT LAB - IFC 91_12058 WH GV 04.01.13 C RELOCATE NCO LAB 120110-00 RWS 995 09.02.03 . H DEVELOPMENT LAB - ECN-01 911_12058 9-12061 WH CEL 06.20.13 D DESIGN ACQUIRE/INSTALL 30100 LIEBERT 11181858 9.9095 RWS 10.26.10 E DEVELOPMENT LAB - 507E IFR WH_12058 9-12061 WH GV 06.22.12 BOE//VG® J LAB SAN 2 (BB ACCEPTABILITY THG DESKXI AND/0R SPECIFICATION 15 APPROVED REVIEWED FOR CODE COMPLIANC APPROVED (1 )UL 292013 City of Tukwila BUILDING DIVISION (L" DATL L. DEWALT RECEIVED CITU OF TUKWILA JUL 1 5 2013 PERMIT CENTER LEGEND GENERAL NOTES 1 > PROVIDE ISOLATION VALVE AND CAP FOR FUTURE CONNECTION. 1" AIR, 3 4"CW. 2. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 3. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES DISCONNECT 1/2" DOMESTIC WATER AND 3/4" CONDENSATE DRAIN FROM EXISTING CR1BB6. REMOVE EXISTING PIPING AND ACCESSORIES AND PROVIDE NEW 1/2" DOMESTIC WATER AND 3/4" CONDENSATE DRAIN PIPING AND ACCESSORIES AS REQUIRED FOR CONNECTION TO NEW COMPUTER ROOM UNIT CR1BB6. PROVIDE NEW 1/2" DOMESTIC WATER AND 3/4" CONDENSATE DRAIN PIPING AND ACCESSORIES FOR CR3BB6. 11 0 it O 8 0 0 0© 040 • FOR CONSTRUCTION CHECKED D. MEYER SUBTIRE FIRST FLOOR PLUMBING PLAN - SOUTH N1E1111111 .■■�....■"rte— 3 ■11■■■■■■■rte .■■1•_■..■■._ .■■MM=MMC i7.l• .■■-..__.._ 1' ■ILME.L■■■■Ill 0 KEY PLAN NOT 1R ECU 8 4 0 2 4 16 SCALE: 1/8" = 1'-0" CURRENT REMSION 9-12061 SYMBOL DATE 06.20.13 APPROIE0 BY DEPT. DATE !AWINLTA W. HENCKEL 2HECKED W. HENCKEL K. RAMSEY APPROVED L LAW 5.17.90 DDE INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 MECHANICAL MASTER COL. A-CC/6-11 DEV. CENTER, WA SHEET 1M114 JOS N0. 89065 COMP NO. DWG NO. 9-53.1-1M114 TO DDC COLD AISLE CONTAINMENT CURTAIN, SEE ARCHITECTURAL DRAWINGS RACK INLET AIR TEMPERATURE SENSOR, SEE PLANS FOR QUANTITY AND LOCATION, TYP 1 1 DDC CONTROL PANEL 1 SITELINK Ir NETWORK SWITCH CONTROL WIRING FROM SERVER RACK TEMPERATURE SENSORS, TYPICAL L ICM CONTROL PANEL W INTELLISLOT C MMUNICATION CARD r -J r J r r FILTER EVAPORATOR COILS 00 FFF 1111 e, 49, e, T T T T SEQUENCE OF OPERATION ROOM TEMPERATURE AND HUMIDITY IS CONTROLLED BY COMPUTER ROOM UNITS WITH STAND ALONE CONTROLS, THAT MAINTAIN PROPER OPERATION •OF THE ASSOCIATED EQUIPMENT AND SENDS A SUMMARY ALARM AND A UNIT FAILURE STATUS TO THE DDC DEFINED BY THE USER. THE DDC SYSTEM WILL MONITOR TEMPERATURE, RELATIVE HUMIDITY, AND A CRU CRITICAL ALARM (UNIT FAILURE) AND A COMMON SUMMARY ALARM POINT. WHERE A COMMON POINT IS NOT AVAILABLE THE DDC SHALL COMBINE THE USER DEFINED POINTS INTO A COMMON POINT CRU CONTROL (CR2BB6 & CR3BB6) THE CRU LOCAL CONTROL PANEL SHALL BE SET TO OPERATE CRU FAN SPEED TO MAINTAIN THE WORST CASE AISLE INLET TEMPERATURE BETWEEN 68 AND 72 DEG F. THE CRU LOCAL CONTROL SHALL CYCLE THE HUMIDIFIER AND THE ELECTRIC REHEAT COIL TO MAINTAIN RETURN AIR HUMIDITY BETWEEN 25 TO 50% RH (CORRESPONDING TO 35 ANI) 65% RH AT THE RACK INLET). IF ONE UNIT HAS FAILED THEN THE HUMIDITY CONTROL FUNCTIONS SHALL BE DISABLED. THE CRU LOCAL CONTROL PANEL SHALL CYCLE THE COMPRESSOR AND THE ECONOMIZER CYCLE TO PROVIDE THE SUPPLY AIR SETPONT AS DETERMINED WITHIN THE CRU CONTROL PANEL THE CRU LOCAL CONTROL PANEL SHALL CYCLE THE COMPRESSOR, THE ECONOMIZER CYCLE AND THE LEE TEMPERATURE CONTROL CIRCUIT AS REQUIRED FOR ENERGY CODE COMPLIANCE AND PROPER EQUIPMENT PROTECTION BY MEASURING THE AMBIENT TEMPERATURE AT THE CONDENSER. CRU CONTROL (CR1BB6) THE CRU LOCAL CONTROL PANEL SHALL BE SET TO OPERATE CRU FAN SPEED AND THE CHILLED WATER CONTROL VALVE TO MAINTAIN THE RETURN AIR TEMPERATURE BETWEEN 80 AND 84 DEG F. THE CRU LOCAL CONTROL SHALL CYCLE THE HUMIDIFIER AND THE ELECTRIC REHEAT COIL TO MAINTAIN RETURN AIR HUMIDITY BETWEEN 25 TO 50% RH (CORRESPONDING TO 35 AND 65% RH AT THE RACK INLET). IF ONE UNIT HAS FAILED THEN THE HUMIDITY CONTROL FUNCTIONS SHALL BE DISABLED. TEAMWORK MODE, ALL UNITS SHALL OPERATE IN TEAMWORK MODE SO DEHUMIDIFICATION AND HUMIDIFICATION DOES NOT OCCUR SIMULTANEOUSLY. ALL UNITS SHALL OPERATE IN TEAMWORK MODE SO COOLING AND HEATING DOES NOT OCCUR SIMULTANEOUSLY. COMPUTER ROOM UNIT CONTROL DIAGRAM (Th SCALE: NTS M4501911 SUPPLY/ AIR \ TO DDC --- :� r --J CONTROL MODULE UNIT r( PRIMARY AIR TERMINAL UNIT SHALL OPERATE CONTINUOUSLY. SEQUENCE OF OPERATIO TERMINAL UNIT PROVIDES VENTILATION AIR AND PO ITIVE PRESSURIZATION OF THE LAB AT ALL TIMES, PRIMARY AIR IS SUPPUED FROM CENTRAL SYSTEM, WHICH OPERATES CONTINUOUSLY. INTERFACE CONTROL DAMPER TO FIRE ALARM SYSTEM TO CLOSE DAMPER WHENEVER THE FIRE SUPPRESSION SYSTEM FOR THE INTEGRATED DEVELOPMENT LAB IS ACTIVATED. TERMINAL UNIT P&ID n SCALE: NTS 11..11.,31/.911 - FROM DDC 81 APPROICD DATE ST8 Err APPROVED DATE DEVELOPMENT LAB - 50% IFR WH_12058 WH GV 06.22.12 DEVELOPMENT LAB - 900 IFR W11_12058 DEVELOPMENT LAB - IFC WH_12058 DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WH WH WH 1V GV CEL 07.12.12 04.01.13 06.20.13 BOE/A/G® ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED ., iNttN LEGEND GENERAL NOTES 1. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. ATE ON HEI M S : L :'PLY. REFRIGERANT PIPING, FOR PIPING DIAGRAM, SEE 0 DRAWN (DATE APPROVED BT DEPT. DATE CHECKED M3111M504 REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 2 9 2013 City of Tukwila BUILDING DIVISION REFERENCE DRAWINGS CONSTRUCTION NOTES SIGNAL TO/FROM OTHER TWO CRUS SERVING THE LAB. PROVIDE ICOM PANEL AND INTELLISLOT COMMUNICATION CARD FOR THE EXISTING COMPUTER ROOM AIR CONDITIONING UNIT. FANS ON NEW UNITS. SHALL BE INSTALLED LOWERED IN THE UNDERFLOOR SPACE. RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION SUBTRE DETAILS - MECHANICAL CURRENT 8845 IN 9-12061 SYMBOL C DATE 06.20.13 CHECKED APPROVED APPROVED DRE INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53.1 DEV. CENTER, WA SHEET M31 1 JOB N0. 9-12061 CO. N0. DWG NO. 9-53.1-M311 12> COMPUTER ROOM COOLING UNIT (CRU) SCHEDULE MARK NUMBER MARK N LOCATION '• • .B TYPE NOMINAL CAPACITY • FAX COIL COOLING CAPACITY CHILLED WATER FILTER DATA HUMIDIFIER ELECTRIC REHEAT COIL AIR FILTER REMARKS ., CAPACITY ESP „ CAPACITY MBH RM TEMP 'F FLOW EWT LWT MAX PD ® A ,O H2 CAP EAT F TYPE & R A EFFICIENCY 52 MAX F P .. • �: FINAL FILTER CR1BB6 H3 LAB (ITDL) WB SELF CONTAINED 30 15 17,100 0.2 352. 331 75 61 72 45 55 62.7 25 22.1 9.6 102,390 5-24x31 45 (MERV 11) 0 3 UEBERT CW1060C, FLOOR MOUNTED CR2BB11 HI LAB --- SELF CONTAINED 12 2.0 5250 0.3 94.5 109.8 75 62.5 22 45 55 30 9.4 11.0 4.89" 77.1 61.5 30 O6 LIEBERT, FLOOR MOUNTED,DOWN-FLOW CR2CC8 K4 LAB 10 SELF CONTAINED 25 5.0 9300 0.3 188.8 225.1 75 62.5 45 45 55 FC2CC2 7.5 17.4 6.4 --- 6-18x24 30 06 LIEBERT, FLOOR MOUNTED,DOWN-FLOW CR2CC7 K3 LAB I SELF CONTAINED 25 5.0 9300 0.3 188.8 225.1 75 62.5 45 45 55 FARR 30/30 7.5 17.4 6.4 --- 6-18x24 LIEBERT, 30 06 FLOOR MOUNTED,DOWN-FLOW CR2CC4 15 1750 SELF CONTAINED _ 25 5.0 9300 0.3 188.8 225.1 75 62.5 45 45 55 109 7.5 17.4 6.4 1.0 6-18x24 30 O 6 LIEBERT, FLOOR MOUNTED,DOWN-FLOW CR2BB6 (' H3 LAB (ITDL) SELF CONTAINED 30 30 18,000 • 0.2 434.5 434.5 70 57 - - - - 22 9.6 107,000 10-18X24 45 0 3 LIEBERT DSE DA125A, FLOOR MOUNTED, DOWN -FLOW CR3BB6 H3 LAB(ITDL)SELF CONTAINED 30 30 18,000 0.2 434.5 434.5 72 57 - - - - 22 9.6 107,000 10-18X24 45 0 3 LIEBERT DSE DA125A, FLOOR MOUNTED, DOWN -FLOW L v FAN COIL UNIT (FC) SCHEDULE MARK NUMBER LOCATION SERVED TYPE TOTAL STAT.PR. IN y� CFM MOTOR COOLING DATA HEATING DATA FILTER DATA MANU./MODEL REMARKS HP* RPM MBH TOTAL MAX FACE VELOCITY FAT F ATF MAX PD H20 EWT 'F LWT 'F GPM MAX PD FT WATER MBH TOTAL EAT F LAT F EWT T LWT 'F GPM MAX PD _LT WATER PREFILTER FINAL FILTER FACE VEL FPM DB WB DB W8 FC2CC1 FIRST FLOOR COOLING 5.0 23,500 30 1750 598 580 77.0 62.7 56.7 54.2 45 55 120 10 --- --- --- --- --- --- --- FARR 30/30 FARR 12' RIGAFLOW 500 TRANE/41H 30' AIR FOIL WHEEL FC2BB1 SECOND FLOOR COOLING 5.0 19,000 30 1750 610 540 77.1 61.5 52.7 50.7 45 55 122 10 --- FARR 30/30 (ARM; RIGAFLOW 500 TRANS/35K 24.5' AIR FOIL WHEEL FC2CC2 FIRST FLOOR HEATING 4.0 11,750 15 1750 --- --- --- --- --- --- --- --- --- --- 366.5 . 75 101 170 140 25 1.0 FARR 30/30 BIGAF 12* Y 500 TRANE/218 22' FC WHEEL FC2BB2 SECOND FLOOR HEATING 4.0 9,500 15 1750 - -- -- 397.0 75 109 170 140 27 1.0 FARR 30 30 / FARR 1Y RICO 500 TRANS 218 / 22" FC WHEEL • 460V/30/60HZ CHILLE' - - .- 1 LE MARK NUMBER TYPE CAPACITY TONS MAXI KW EVAPORATOR CONDENSER FAN MOTORS FLOW GPM EW1 'F LWT 'F ' i PASS MAX PD FT H2O FOULING REFRIG FLOW GPM EWT 'F NO•„ '' - •FT MAX PD H20 IIA NG FACTOR REMARKS CH1B-2 SCREW 280 208 750 53 44 3 24.43 ARI - '-22 900_ CAST IRON BRONZE 20.52 .00025 TRANE RTHA 300, LONG SHELL OR APPROVED 15 1750 END SUCTION PACO, 4095-7 BRG FRAME 62 PU1B-1B CONDENSER WATER 85' 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095-7 BRG FRAME 62 COOLING TOWER (CT) SCHEDULE MARK NUMBER GPM EWT 'F LWT 'F AMBIENT AIR FANS FAN MOTORS SUMP HEATER REMARKS F DB F WB N0. TYPE CFM N0. HP• NO. KW CTRB-2 900 94 85 85 68 3 CENTRIF. 49770 1 01.5 0 1 5 BALTIMORE AIR COIL VXTN215 OR APPROVED (SPECIAL ORDER) CAST IRON BRONZE 75 8 DIRECT 15 1750 END SUCTION PACO, 4095-7 BRG FRAME 62 PU1B-1B CONDENSER WATER 85' 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095-7 BRG FRAME 62 460V/30/60HZ PUMP (PMP) SCHEDULE NUMBER SERVICE FLUID 'F TEMP CAPACITY SIZE (N) CONSTRUCTION PERFORMANCE MOTORMARK PUMP TYPE MANUFACTURER AND MODEL REMARK GPM TDH SUCT DISCH BODY FITTINGS EFF N FT R DRIVE TYPE HP' RPM PU1B-1A CHW WATER 53' 750 40 5 4 CAST IRON BRONZE 75 8 DIRECT 15 1750 END SUCTION PACO, 4095-7 BRG FRAME 62 PU1B-1B CONDENSER WATER 85' 900 50 6 5 CAST IRON BRONZE 77 9 DIRECT 20 1750 END SUCTION PACO, 5095-7 BRG FRAME 62 460V/30/60HZ NOT INCLUDED IN PHASE 3 CONTRACT (WILL BE REQUIRED FOR FUTURE PHASE 4 ADDITION) REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 City of Tukwila BUILDING DIVISION CONSTRUCTION NOTES PROVIDE NEW EQUIPMENT REMOVE EXISTING COMPUTER ROOM UNIT AND INSTALL NEW COMPUTER ROOM UNIT FURNISHED BY BOEING. PROTECT EXISTING COMPUTER ROOM FROM DAMAGE AND DEUVER TO LOCATION AT DEVELOPMENTAL CENTER AS DIRECTED BY. BOEING CONSTRUCTION MANAGER. RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER FOR CONSTRUCTION STM 8 REASON 6* APPROVED DATE STM REASON R1 LAB REVISION MJC KMR /LL 9.7.90 DEVELOPMENT LAB - ECN-01 WH_12058 BY WH APPROVED DATE CEL 06.20.13 RECORD DRAWING DEVELOPMENT LAB - 508 IFR WH_12058 DEVELOPMENT LAB - 90% IFR WH_12058 MJC WH KMR /6B CV 8.30.91 06.22.12 DEVELOPMENT LAB - IFC W11_12058 WM WH GO GO 07.12.12 04.01.13 glAriirkw,fsec. DRAWN LDE WALT ACCEPTABILITY THIS DESIGN MND/0R CHECKLO SPECIFICATION IS APPROVED W..HEANCKEL DATE D.MEYER APPROVED Br CHECKED W.AENC .HENC APPRENID KSET DEPT. DATE SUBrtRE SCHEDULES COMM REMSIOH 9-12061 SYMBOL F DATE 06.20.13 APPPROVED L LAW 5.17.90 INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 MECHANICAL MASTER DEV. CENTER, WA SNEET M360 .108 N0. DNS N0. 9-12061 PMP No. 9-53.1-M360 AIR DIFFUSER/REGISTER/GRILLE SCHEDULE MARKNECK NUMBERINCHES TYPE MATERIAL FINISH FACE SIZE INLET/ SIZE INCHES MAXIMUM NOISE COEFFICIENT MAXIMUM TP INCH WG MAXIMUM SET CFM REMARKS CD -1 SQUARE CEILING DIFFUSER STEEL WHITE 12x12 60 20 .060 140 CARNES SJTA CD -2 SQUARE CEILING DIFFUSER STEEL WHITE 24x24 80 21 .110 275 CARNES SJTA CD -3 SQUARE CEILING DIFFUSFR STEEL WHITE 24x24 100 . 24 .130 425 CARNES SJTA CD -4 CEILING DIFFUSR STEEL STEEL WHITE 24x24 120 23 .127 550 CARNES SJTA CD -5 CEILING DIFFUSER STEEL STEEL WHITE 24x24 140 29 .240 950 CARNES SJTA CD -6 CEILING DIFFU1FR STEEL STEEL WHITE 240 80 26 .08 260 CARNES SSAA CD -7 ROUND CEILING DIFFUSFR STEEL WHITE 300 100 26 .07 315 CARNES SSAA CD -8 - STEEL WHITE 400 140 24 .03 750 CARNES SSAA RG -1 RROUND�RCEILING rEE771�� "ACcTED �CEEILING STEEL WHITE 24x24 80 21 .04 550 CARNES SPRB222 RG -2 PE?RT�UFORA��7,ERRD`` EILING STEEL WHITE 24x24 120 20 .03 800 CARNES SPRB222 RG -3 PRFORATEDLIDNG R RNV E_ STEEL WHITE 12x24 --- 20 .02 300 CARNES SPRB222 EY -1 _ EXHAUST GRILLE aSTE ~WHIT IES V � a a4 ,4 _ a .7 VANES CVESRAM� FSD 1 FLOOR SUPPLY DIFFUSER STEEL WHITE 24x24 03 1500 TATE DIRECT AIR, SEE M450 FOR DAMPER QTY ) EXHAUST FAN (EF) SCHEDULE MARK NUMBER LOCATION AREA SERVED (ROOM N0.) EXHAUST FAN SECTION REMARKS FAN SIZE MFG. SIZE NO. ARRNGMT. NUMBER CFM (' MAX) TOTAL STATIC PRESS. INCHES WG MAX. OUTLET VELOCITY FPM APPROX. RPM DRIVE SIDE INLET GUIDE VANES MOTOR HP EFRCCIO ROOF TOILET ROOM(S) 18' CRE -18F - 2650 3/4 1400 510 - - 1 GREENHECK LB -18-10 W/ BIRD SCREEN AND B.D. EFRCC3 ROOF STORAGE 9' CRE -9F - 875 3/4 1550 1029 - - 1/2 GREENHECK LB -10-5 W/ BIRD SCREEN AND B.D. EF2CC2 FAN ROOM FIRST FLOOR 44' 44 1 20,000* 1.5 1620 771 - - 10 TRANE MODEL 0, AXIAL FLOW 112882 FAN ROOM SECOND FLOOR 40' 40 1 16,200' 1.5 1480 852 - - 7.5 TRANE MODEL 0, AXIAL FLOW FD -1 FLOOR DRAIN 2 2 - - - FD -2 FLOOR DRAIN 2 - - - W/ FUNNEL F5-1 FLOOR SINK 6 3 - - FLOOR SINK \ ) PLUMBING FIXTURE CONNECTION SCHEDULE MARK NUMBER DESCRIPTION CONNECTION (INCHES) REMARKS SAN VENT HW CW P-1 WATER CLOSET 4 2 - 1 WALL -HUNG FLUSH VALVE P -1A WATER CLOSET 4 2 - 1 WALL -HUNG FLUSH VALVE (HANDICAP) P-2 URINAL 2 1 1/2 - 3/4 WALL -HUNG FLUSH VALVE P-3 LAVATORY 1 1/4 1 1/4 1/2 1/2 OVAL COUNTER RECESSED P -3A LAVATORY 1 1/4 1 1/4 1/2 1/2 OVAL COUNTER RECESSED (HANDICAP) P-4 SERVICE SINK 3 2 1/2 1/2 FLOOR TYPE P-5 ELECTRIC WATER COOLER 1 1/4 1 1/4 - 1/2 WALL MOUNTED (HANDICAP) P-6 SINK 2 11/2 1/2 1/2 - P-7 EMERG EYE WASH 1 1/4 1 1/4 - 1/2 - FD -1 FLOOR DRAIN 2 2 - - - FD -2 FLOOR DRAIN 2 - - - W/ FUNNEL F5-1 FLOOR SINK 6 3 - - FLOOR SINK \ DOMESTIC HOT WATER HEATER (HWH) SCHEDULE MARK NUMBER KW INPUT TANK STORAGE GALLONS STAMP RECOVERY ELECTRICAL REMARKS GPM d VOLTS/PH/HZ HW -1 9 65 ASME 37 100 480/3/60 A.O.SMITH MOD. DSE-65 HW -2 1.5 6 — 6 100 120/1/60 A.O.SMITH MOD. DEL -6 100-300 0.30 35 6 300 4 150 10x8 5 TITUS EDV -3100 W-3 200-600 0.30 35 8 600 VARIABLE AIR VOLUME TERMINAL UNIT (VAV) SCHEDULE MARK NUMBER AIR QUANT. RANGE CFM PRIMARY AIR PRESSURE DROP AT MAXIMUM INCH WG MAX. NC LEVEL 0 1.5' WG INLET COOING HEATING DISCHARGE DUCT REMARKS SIZE (INCH) CFM INLET SIZE CFM SIZE SOUND UNE LENGTH FEET W-1 0-150 0.30 35 4 150 4 100 8x6 4 TITUS EDV -3100 W-2 100-300 0.30 35 6 300 4 150 10x8 5 TITUS EDV -3100 W-3 200-600 0.30 35 8 600 6 300 12x10 6 TITUS EDV -3100 W-4 300-900 0.30 35 10 900 8 450 14x12 7 TITUS EDV -3100 4110 W-6 0-150 0.30 35 4 100 4 100 8x6 4 TITUS DESV CONDENSING UNIT SCHEDULE MARK NUMBER INDOOR UNIT LOCATION TYPE SERVICE CONDITIONS FANS ELECTRICAL REMARKS THR MBH AMBIENT DB TEMP DEG F REFRIGERANT TYPE TYPE NUMBER OF FANS AIRFLOWVOLTS CFMKw REMARKS PRE -1 PHASE HZ ACCU-1 CR2B86 OUTDOOR AIR COOLED CONDENSER 360 95 R410A PROP 4 37730 2 460 3 60 LIEBERT MCL220 ACCU-2 CR2BB6 OUTDOOR AIR COOLED CONDENSER 360 95 R410A PROP 4 37730 2 460 3 60 LIEBERT MCL220 PUMPED REFRIGERANT ECONOMIZER MARK NUMBER INDOOR UNIT OUTDOOR UNIT LOCATION SERVICE CONDITIONS ELECTRICAL THR MBH AMBIENT DB TEMP DEG F REFRIGERANT TYPE KW VOLTS PRASE HZ REMARKS PRE -1 CR2BB6 ACU -1 OUTDOOR XXX XXX R410A 3.2 460 3 60 LIEBERT PRE PRE -2 CR3BB6 ACU -2 OUTDOOR XXX XXX R410A 3.2 460 3 60 LIEBERT PRE SVM RE\15AN Tn APFROIFD 841E SYM REV610N A RECORD DRAWING MJC KMR /RB 8.30.91 F DEVELOPMENT LAB - ADDENDUM 3 WH_12058 B DROPPED CLGS RMS 12883 & 11884 HARR 09/07/11 G DEVELOPMENT LAB - ECN-01 WH_12058 C DEVELOPMENT LAB - 500 TER WH_12058 WH GV 06.22.12 D DEVELOPMENT LAB - 900 W6 V61_12058 WH GV 07.12.12 E DEVELOPMENT LA8 - IFC WH -12058 WH GV 04.01.13 01 APPRENED 841E WH WH GV 04.12.13 DMD 06.20.13 g;LAsArAsw. CONSTRUCTION NOTES PROVIDE NEW EQUIPMENT REVIEWED FOR CODE COMPLIANCE APPROVED 'JUL 2 9 2013 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION ACCEPTABILITY LDE WALT 1810 SUBTITLE TRIS OE9GN AND/OR CHLCEW W ENCKEi SP 9104Tx1N IS MED PROV APPROVED 00 DEPT. DATE 0.0EYER CHECKED W.HENCKEL APPROVED K.RAMSEY APPROVED L LAW RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER SCHEDULES CURRENT REVISION SYMBOL DATE 9-12061 G 06.20.13 T'T'E INTEGRATED TECHNICAL DEVELOPMENT LAB 5.17.90 MECHANICAL MASTER BUILDING 9-53.1 SHEET M361 .rob N0. COMP N0. DEV. CENTER, WA D'''Gf 0. 9-53.1-88361 a MAINTAIN ALL REQUIRED ACCESS AREAS, TYP 1-3/8'RL 7/8 RL 7/8"RL 7/8"RL 1-3/8"RL 1-3 8"RL 0 0 ACCO 1 � 0 0 1-3/8"RS 1 -3/8"RL CONCRETE HOUSEKEEPING PAD, SEE STRUCTURAL 1 -3/8 -RS 1 -3/8"RS 1 -3/8"RS 1-3/8"RS 1 -3/8"RL 1 -3/8"RL 1-3/8"RL 1 -3/8"RL 1-3/8"RL 7/8 RL 8"RL PIPE SUPPORT ACCO M450 DDC PANEL NETWORK SWITCH AND SITEUNK 7/8"RL 1 -3/8"RL 1-3/8"RL --1 r--1 r -- _-J L__J L__ M450 M451 RACK -MOUNTED SENSOR, TYPICAL 1- I DDC SENSOR IN I I COLD AISLE I- ----- 4 (CEILING MOUNTED)I IL I I I�-72" (MIN)—I I -1 BETWEEN RACKS L _ _ _ -HI ® FSD-1, TYP OF 24 �-Q I TO VAV TERMINAL UNIT, SEE 1M13 ■ ■ ■ ■ ©(T �P) ■ DDC SENSOR IN COLD AISLE (CEILING MOUNTED) TO DDC SYS IEM FOR MONITORING REVIEWED FOR CODE COMPLIANCE APPROVED JUL 79 2013 1 126 1 City of Tukwila BUILDING DIVISION ENLARGED PLAN SCALE 1/4" = 1'-0" 1M13,1M14 M450 (& RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER LEGEND GENERAL NOTES 1. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND M1-1. 2. GENERAL NOTES ON SHEET M2 SHALL APPLY. 3. FOR SYSTEM PIPING DIAGRAM, SEE M450 M504 4. FOR CONTROL DIAGRAM, SEE M450 M311 REFERENCE DRAWINGS CONSTRUCTION NOTES I> TEMPERATURE SENSORS AT EACH RACK. CONNECT TO COMPUTER ROOM UNIT ICOM CR2BB6 CONTROL SYSTEM. LOCATE TEMPERATURE SENSOR AND LEAK SENSOR BELOW THE RAISED FLOOR. SAVE FLOOR TILES REMOVED FOR PLACEMENT OF THE FLOOR SUPPLY DIFFUSERS. INSPECT ALL FLOOR TILES FOR CRACKS, DAMAGE, CABLE AND PIPE PENETRATIONS. REPLACE DAMAGED TILES, AND SEAL ALL PIPE, CABLE AND CONDUIT PENETRATIONS AIRTIGHT. START/STOP AND SMOKE DETECTORS ON NEW UNITS, BY DDC. ® NEW COMPUTER ROOM AIR CONDITIONING UNITS. SPACE SENSORS MONITORED BY DDC SYSTEM. REMOVE EXISTING UPFLOW CRU AND INSTALL NEW DOWN -FLOW CRU CR1B66, FURNISHED BY BOEING. TURN EXISTING CRU OVER TO BOEING. MINIMUM CLEARANCE AREA IN FRONT OF COMPUTER ROOM UNITS. ® TAB CONTRACTOR SHALL PROPORTIONALLY CLOSE DAMPERS WHERE RACKS ARE NOT FULL AND COMPLETELY CLOSE DAMPERS WHERE FLOOR SUPPLY DIFFUSERS ARE IN FRONT OF FUTURE RACKS. CONTINUE TO CLOSE ALL DAMPERS WHILE ALL COMPUTER ROOM SUPPLY FANS 'ARE IN 100% OPERATION UNTIL 0.3 INCH W.C. OR 45,000 CFM IS MEASURED. MEASURE UNDER FLOOR PRESSURE AT THE LOCATION OF THIS NOTE. PROVIDE FIRST FOUR FLOOR SUPPLY DIFFUSERS IN EACH ROW WITHOUT OPPOSED BLADE DAMPERS. ® TEMPERATURE SENSORS AT EACH RACK. CONNECT TO COMPUTER ROOM UNIT iCOM CR3BB6 CONTROL SYSTEM. PROVIDE ADDITIONAL CABLE TYPE LIQUID SENSOR CONNECT TO CR1BB6. 35 FT IN LENGTH. 11 ,g0 CMS) C 0 OO ®1 1' 0 EXISTING B _DG 9- 53 LED 0 4 KEY PLAN NOT TO WALE FOR CONSTRUCTION 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" SYM A BY APPROVED DATE 5YM REVISER BY APPROVED DEVELOPMENT LAB - 50% 1FR W1_12058 DEVELOPMENT LAB - 905 IFR W1_12058 WH WH GV OV 06 22.12 DEVELOPMENT LAB - ECN-01 WH_12058 9-12061 WH DOD 06.20.13 07 12 12 DEVELOPMENT LAB - IFC W11_12058 WH GV 04 01.13 C DEVELOPMENT LAD - ADDENDUM 3 WH_12058 WH GV 04 12.13 0 DEVELOPMENT LAB - RF1-08 WH_12058 9-12061 WH CEL 06.11.13 e;LAiousrEzisfc. • wN ACCEPTABILITY 1H15 DESIGN AND/OR SPEGIFlCATKIN 6 APPROVED iNDINEW APPROVED BY DEPT. DATE CHECKED DATE SUBORE ENLARGED PLAN CURRENT REMSKDN 9-12061 S111B0E E DATE 06.20.13 'NECKED APPROVED APPROVED T"`E INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 MECHANICAL MASTER COL. BB-CC/6-5 DEV. CENTER, WA SNEET M450 A08 NO. 9-12061 CHIP N0. ONG N0. 9-53.1-M450 • SEAL AROUND THE UNIT, USE ASTM 84 COMPLIANT FOAM OR NEOPRENE 16 GA SHEET METAL . WIDTH OF UNIT, COO SEISMIC SUPPORTS T 7/8"RL t 1-3/8"RS %J7/8RL i I [ I CR 88 . 21_1E19 . SEAL AROUND THE UNIT, USE ASTM 84 COMPLIANT FOAM OR NEOPRENE CR 7889 DDC PANEL It 1 1 I I I I I 5-1 Ifh'"""I11:114* I '.•.il IL 14 ILIEJIlt!! I I I MINIM la Ce CWO T ULTAI C(Yl(1D HAI F \ --SEISMIC SUPPORT PROVIDED SCOOP, HALF RDINATE WITH YPICAL WITH THE UNIT SECTION SCALE: 1/4" = 1'-0" 1 1 M450 M451 WIDTH OF UNIT, COORDINATE WITH SEISMIC SUPPORTS TYPICAL SEISMIC SUPPORT PROVIDED WITH THE UNIT SECTION SCALE: • 1/4" = 1-OJD RJ� 7/8"RL FANS IN UNDERFLOOR PLENUM' M450 M451 LEGEND GENERAL NOTES 1. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND -M1-1. 2. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES INSTALL AND COMMISSION 30—TON DOWN—FLOW CHILLED WATER COMPUTER ROOM UNIT, FURNISHED BY BOEING. PROVIDE AIR SCOOP AND SUPPORT FRAME. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION - DEVELOPMENT LAB - 50% IFR WH_12058 A DEVELOPMENT IAB - 90R IFR WH_12058 B DEVELOPMENT lAB - IFC WH_12058 C DEVELOPMENT LAB - ECN-01 901-12058 9-12061 06.22.12 07.12. 12 04.01.13 06.20.13 g)LA APPROVED BY DEPT. MECHANICAL SECTION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" CURRENT REASON 9-12061 DATE 06.20.13 TD'E INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 MECHANICAL MASTER COL. BB—CC 6-5 DEV. CENTER, WA 9-12061 9-53.1—M451 + t I [ I CR 88 . 21_1E19 . SEAL AROUND THE UNIT, USE ASTM 84 COMPLIANT FOAM OR NEOPRENE It 1 1 I I I I I 5-1 Ifh'"""I11:114* I '.•.il IL 14 ILIEJIlt!! I I I MINIM la Ce CWO T ULTAI C(Yl(1D HAI F WIDTH OF UNIT, COORDINATE WITH SEISMIC SUPPORTS TYPICAL SEISMIC SUPPORT PROVIDED WITH THE UNIT SECTION SCALE: • 1/4" = 1-OJD RJ� 7/8"RL FANS IN UNDERFLOOR PLENUM' M450 M451 LEGEND GENERAL NOTES 1. FOR SYMBOLS AND ABBREVIATIONS, REFER TO SHEETS M1 AND -M1-1. 2. GENERAL NOTES ON SHEET M2 SHALL APPLY. REFERENCE DRAWINGS CONSTRUCTION NOTES INSTALL AND COMMISSION 30—TON DOWN—FLOW CHILLED WATER COMPUTER ROOM UNIT, FURNISHED BY BOEING. PROVIDE AIR SCOOP AND SUPPORT FRAME. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION - DEVELOPMENT LAB - 50% IFR WH_12058 A DEVELOPMENT IAB - 90R IFR WH_12058 B DEVELOPMENT lAB - IFC WH_12058 C DEVELOPMENT LAB - ECN-01 901-12058 9-12061 06.22.12 07.12. 12 04.01.13 06.20.13 g)LA APPROVED BY DEPT. MECHANICAL SECTION RECEIVED CITY OF TUKWILA JUL 1 5 2013 PERMIT CENTER 4 2 0 2 4 8 SCALE: 1/4" = 1'-0" CURRENT REASON 9-12061 DATE 06.20.13 TD'E INTEGRATED TECHNICAL DEVELOPMENT LAB BUILDING 9-53.1 MECHANICAL MASTER COL. BB—CC 6-5 DEV. CENTER, WA 9-12061 9-53.1—M451 1/2" CW 3/4" CD #77—BUILDING EXTERIOR WALL RL RL EVAPORATOR COILS CONDENSATE PUMP -- 1] SLOPE 1/8'/FT PCD TERMINATE 2" ABOVE THE BOTTOM OF THE FLOOR SINK I \ SYM (E)FLOOR SINK 1/2" FULL PORT BALL VALVE, WITH CAPPED HOSE CONNECTION UNDERFLOOR PLENUM SUPPORT CHANNELS, SPACED AT 3 FEET Xt 11__ 49. 43 d RS RS ALL PIPE PENETRATIONS SHALL BE SEALED AIRTIGHT FULL PORT BALL VALVE MI/ v 04 04 ACCO GI 1-3/8"RL '_—PN— 1-3/8"RL 7/8"RL 1-3/8"RS COMPUTER ROOM UNIT PIPING DIAGRAM SCALE: NTS 1M113, 1M114, M311, M450 M504 1-3/8"RL� 1-3/8"RL 4- 8'-0" 1-3/8"RL „,....„7P -- RL EXIST. FLOOR REF. ELEV. 0'-0" 7/8 -RL 7/8"RL 7/8"RL 7/8'RL 2 1 1 5/8" x 4' x 4" 1/4 A36 STEEL PLATE PIPE INSULATION (TYP) PIPE CLAMP (WP) / 1-3/8 RL r 1-3/8"RL 1-3/8"RL 1-3/8"RL 1 ) 1-3/8"RS el 1/2"0 HILTI KWIK BOLT II MIN EMBED 3 1/2' (INTO EXIST CONCRETE), TYP FOR BASE PLATE DETAIL, SEE DEVELOPMENT LAB - 50% IFR W11_12058 3 1-3/8"RS Rl 1-3/8"RS 1-3/8'RS 777 CONCRETE PAD NON -SHRINK GROUT 1-3/8"RS' TS 4 X 4 X 1/4 1 1/4" TYP. CONCRETE PAD, SEE STRUCTURAL O DRILL FOR 1/2"0 HILTI KWIK BOLT TTP. 5/8' x 8' x 8" A36 STEEL PLATE BASE PLATES SHALL BE POSITIONED ON THE NEW EQUIPMENT PAD. POSITION THE PLATES SUCH THAT THE CENTER OF THE PLATES IS AT LEAST 9 INCH FROM THE EDGE OF THE PAD. BASE P_ATE SCALE: NTS M504 M504 M504 1504 WTI GV PIPE SUPPORT SCALE: NTS DATE 06.22.12 SYN M450 M504 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 City of Tukwila IJ ATTACH TO STRUCTURE (TTP 22 GAUGE GALVANIZED STEEL HARD DUCT LONG RADIUS ELBOW, SEGMENTED ELBOWS ARE NOT PERMITTED INSULATION EQUALIZING GRID SUPPORT AT MIDPOINT OF FLEX HANGER STRAP FLEX DUCT -SAME SIZE AS DIFFUSER INLET OR AS INDICATED ON FLOOR PLANS (5' MAX LENGTH AND 45' TURN ANGLE) SUPPLY DUCT OUND DIFFUSER NECK LAY -IN CEILING CEILING DIFFUSER, CD1 CELING DIFFUSER CD1 SCALE: NONE J PROVIDE FLEX DUCT WITH ROLL BACK AND CLAMP ALL CONNECTIONS SO THAT NO FIBERGLASS IS EXPOSED FOR CONSTRUCTION DA A DEVELOPMENT LAB - 90% IFR W1_12058 WH GV 07.12.12 DEVELOPMENT LAB -IFC W11_12058 WH GV 04.01.13 DEVELOPMENT LAB - ADDENDUM 3 W11_12058 W11 GV 04.12.13 D DEVELOPMENT LAB - ECN-01 W11_12068 CEL 06.20.13 g)LAFIEZEZAW ACCEPTABILITY T165 DESIGN 005/0R u¢GK4u SPEGflCA1 N 0 APPROVED APPROVED BY DEPT. DATE SDE RRE DETAILS - MECHANICAL RECEIVED CITY OF TUKWILA 1(4-4 1 5 2013 PERMIT CENTER CORRENT REVISION 9-12061 504604 DA 06.20.13 CNECKED INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53 DEV. CENTER, WA SHEET M504 MO H0. 9-12061 506? H0. DWG 9-53.1-M504 DA A DEVELOPMENT LAB - 90% IFR W1_12058 WH GV 07.12.12 DEVELOPMENT LAB -IFC W11_12058 WH GV 04.01.13 DEVELOPMENT LAB - ADDENDUM 3 W11_12058 W11 GV 04.12.13 D DEVELOPMENT LAB - ECN-01 W11_12068 CEL 06.20.13 g)LAFIEZEZAW ACCEPTABILITY T165 DESIGN 005/0R u¢GK4u SPEGflCA1 N 0 APPROVED APPROVED BY DEPT. DATE SDE RRE DETAILS - MECHANICAL RECEIVED CITY OF TUKWILA 1(4-4 1 5 2013 PERMIT CENTER CORRENT REVISION 9-12061 504604 DA 06.20.13 CNECKED INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53 DEV. CENTER, WA SHEET M504 MO H0. 9-12061 506? H0. DWG 9-53.1-M504 EXISTING 3' BUTTERFLY (2). 3' x 2' RED. EL (2) 3' 4 BOLT FLANGE (2) 2' BLK RAISED FLOOR LEVEL 1 1/2' OUICK DISCONNECT PETE'S PLUGS (TIP. 4) 1 1/Y STRAINER (TYP OF 2) CONNECT TO A/C W/ 1 1/2' FEMALE COPPER SWEAT x 1 1/2' FPT - BRONZE ADAPTER. ISOLATION VALVE 1 1/2' SUPPLY & RETURN DETAIL SCALE: NTS 1M50.612,14 61 1' ISOLATION VALVE CHWS & MYR 1' STRAINER W/20 MESH SCREEN AND DRAIN VALVE W/ GARDEN HOSE CONNECTION & CAP 1' UNION 1' x 3/4' REDUCER 2 - TON 1' ISOLATION - - SPOT COOLER VALVE , 'UEBERT', 208 V, 1 0, 60 N C145- SEE DWG. 109-053-4033 M-1 FOR COMPLETE DESCRIPTION r HOSE BIBB WITH .,,YR• CONHOSE G" CONNECTION TIONON BOTH SUPPLY & RETURN (TYP1C0L) P- TRAP ROUTE TO EXIST. FLOOR SINK (SEE PLAN) SPOT COOLER ISOMETRIC SCALE:. NTS 5EE ARCHITECTURAL TWYG. A-504 FOR STRUCTURAL SUPPORT v cHWS LI¢'CI4WR RAISED FLOOR LEVEL DETAIL 3L' PUMPED COND. DRAIN 3 SCALE: NTS 1M6411_11506 114114 O LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES 1I. REMOVE EXISTING A/C UNIT CR18B6 AND DISCONNECT ALL ASSOCIATED PIPING. RECONFIGURE EXISTING PIPING AND RE -CONNECT TO NEW CR1BB6. INSTALL AND COMMISSION NEW CR1BB6, FURNISHED BY BOEING. RE -USE EXISTING PIPING AND DEVICES AND RECONFIGURE FOR INSTALLATION AT NEW CR18B6. INSTALL ALL DEVICES (VALVES, STRAINERS, PETE'S PLUGS, BALANCING VALVE) IN AN ACCESSIBLE LOCATION. BALANCE VALVE SETTING SHALL REMAIN UNCHANGED, REPORT SETTING AND PRESSURE DROP. REVIEWED FOR CODE COMPLIANCE APPROVED JUL 9 9 2013 City of Tukwila BUILDING DIVISION FOR CONSTRUCTION RECEIVED CITY OF TUKWILA JUL 1 5 2613 PERMIT CENTER SIM REVISON BY 1PPRDIm MR SYM REVISOR 88 usaam DAR CONVERSION FROM MYLAR TO CAD RELOCATE NOD LAD 120110-00 B C D DESIGN ACQUIRE/INSTALL 30T0N UEBERT Y1 AND UT17 LAD UPGRADES DEVELOPMENT LAB - ECN-01 WH_12058 11181858 9-12061 CCSI RWS M.WONG WH WH 12.10.00 RWS RWS GV CEL 09.02.03 10.26.10 09.07.12 06.20.13 BOE/A/G® ACCEPTABILITY 146 DESIGN 4010 /04 SPECIFICATION IS APPROYED APPROIED BY DEPT. DAR S EEYYNOLDS 5.19.88 CHECKED SUBTITLE PIPING DETAILS CURRENT REVISION 9-12061 SIMBOL D DATE 06.20.13 NIINLEN S.ROSSE 5.19.88 CHECKED D.E.L APPROVED APPROVED E.CARRIG N 5.20.88 5.20.88 T"r INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53 DEV. CENTER, WA SHEET 1M506 JOB N0. 11181858 COMP NO. MONO. 9-53-1M506 RECEIVED CITY OF TUKWILA JUL 1 5 2613 PERMIT CENTER SIM REVISON BY 1PPRDIm MR SYM REVISOR 88 usaam DAR CONVERSION FROM MYLAR TO CAD RELOCATE NOD LAD 120110-00 B C D DESIGN ACQUIRE/INSTALL 30T0N UEBERT Y1 AND UT17 LAD UPGRADES DEVELOPMENT LAB - ECN-01 WH_12058 11181858 9-12061 CCSI RWS M.WONG WH WH 12.10.00 RWS RWS GV CEL 09.02.03 10.26.10 09.07.12 06.20.13 BOE/A/G® ACCEPTABILITY 146 DESIGN 4010 /04 SPECIFICATION IS APPROYED APPROIED BY DEPT. DAR S EEYYNOLDS 5.19.88 CHECKED SUBTITLE PIPING DETAILS CURRENT REVISION 9-12061 SIMBOL D DATE 06.20.13 NIINLEN S.ROSSE 5.19.88 CHECKED D.E.L APPROVED APPROVED E.CARRIG N 5.20.88 5.20.88 T"r INTEGRATED TECHNICAL DEVELOPMENT LAB MECHANICAL MASTER BUILDING 9-53 DEV. CENTER, WA SHEET 1M506 JOB N0. 11181858 COMP NO. MONO. 9-53-1M506 :016DERMIT COORS, O rt•C r'! ,4. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: PG13-100 DATE: 07/15/13 PROJECT NAME: BOEING #9-53 SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division ❑ u lic Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 07/16/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route N Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 08/13/13 Approved ❑ Approved with Conditions 't Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or TradespeopleA''Friendly Page General/Specialty Contractor A business registered as a construction contractor with LW to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name AUBURN MECHANICAL INC UBI No. 600074968 Phone 2538389780 Status Active Address Po Box 249 License No. AUBURMI163BA Suite/Apt. License Type Construction Contractor City Auburn Effective Date 1/1/1984 State WA Expiration Date 9/12/2014 Zip 98071 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUBURMI184LAAUBURN MECHANICAL INC Construction Contractor Plumbing Unused 6/1/1982 1/1/1984 Archived Business Owner Information Name Role Effective Date Expiration Date THODAY, DAVID V President 01/01/1980 Amount JOHNSON, STACY ANNE President 01/01/1980 DTC08057R723PHX12 JOHNSON, KIM PAUL Secretary 02/06/2009 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 FIDELITY Et DEPOSIT CO OF MD LPM8047218 09/01/2001 Until Cancelled $12,000.00 09/12/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 29 Phoenix Insurance Company, The DTC08057R723PHX12 10/01/2012 10/01/2013 $1,000,000.00 09/25/2012 28 Phoenix Insurance Company, The DTC08057R723PHX11 10/01/2011 10/01/2012 $1,000,000.0009/20/2011 27 PHOENIX INS CO DTC08057R723PHX10 10/01 /2010 Until Cancelled $1,000,000.00 09/27/2010 26 Continental Western Ins Co CWP258632926 10/01/2009 10/01/2010 $1,000,000.00 10/05/2009 25 CONTINENTAL WESTERN INS CO CWP258632923 09/01/2008 09/01/2009 $1,000,000.00 08/28/2008 24 CONTINENTAL WESTERN CWP2586329 09/01/2005 09/01/2008 $1,000,000.0008/13/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httns://fortress.wa. aov/1ni/bbin/Print.asnx 08/02/2013