HomeMy WebLinkAboutPermit PL10-034 - KING COUNTY / VERIZON WIRELESS - TYPE 1 CELL TOWER WIRELESS TELECOMMUNICATIONSVERIZON WIRELESS 18800 ORILLIA RD PL1 0-034 L10-040 WIRELESS TELECOMMUNICATIONS FACILITY City of Tukwila Jinn Haggerton, Meryor Department of Community_Development NOTICE OF DECISION Jack Pace, Director August 16, 2010 TO: Sarah Telschow of RealCom Associates, Applicant King County, Owner This letter serves as a notice of decision and is issued pursuant to TMC 18.104.170 on the following project and permit approval. Project File Number: Applicant: Type of Permit Applied for: Project Description: Location: Associated Files: Zoning: . PROJECT INFORMATION L10-040 Sarah Telschow of RealCom Associates on behalf of Verizon Wireless Type 1 Wireless Communications Facility Permit The applicant is requesting approval of a Type 1 Wireless Facilities Permit to install one (1) two -foot diameter microwave dish on an existing 60 -foot tower andadd one (1) new equipment cabinet within the existing equipment enclosure. The proposal does not increase the height of the existing tower or the size of the enclosure area. 18800 Orillia Road L99-0062, Permit for existing 60' monopole and two (2) antennas. L2000-012, Permit for four (4) additional antennas on existing monopole. D07-023, Relocation of antennas from middle platform to top platform was approved, but file was closed due to inactivity. L09-058, Installation of four (4) new panel antennas on existing pole and to move six (6) existing antennas to the vacant platform at the top of pole. Tukwila Valley South (TVS) II. DECISION SEPA Determination: The City SEPA Responsible Official has previously determined that this application does not require a SEPA threshold determination because it is categorically exempt. Decision on Substantive Permit: The Community Development Director has determined that the application for a Type 1 Wireless Communications Facility Permit complies with applicable City and state code requirements and has approved that application, subject to any conditions which are set forth in the Decision based on the findings and conclusions contained in the staff report. CT Page 1 of 2 W:\Users\Courtney\L Files \L10-040 WCF Type 1\2010_08_16_NOD.doc 08/12/2010 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 III. YOUR APPEAL RIGHTS The Decision on this Permit Application is a Type 1 decision pursuant to Tukwila Municipal Code §18.104.010. Other land use applications related to this project may still be pending. One administrative appeal to the Hearing Examiner of the Decision on the Permit itself is permitted. A party who is not satisfied with the outcome of the administrative appeal process may file an appeal in King County Superior Court from the Hearing Examiner decision. IV. PROCEDURES AND TIME FOR APPEALING In order to appeal the Community Development Director's decision on the Permit Application, a written notice of appeal must be filed with the Department of Community Development within 14 days of the issuance of this Decision, which is by August 30, 2010. The requirements for such appeals are set forth in Tukwila Municipal Code 18.116. All appeal materials shall be submitted to the Department of Community Development. Appeal materials MUST include: 1. The name of the appealing party. 2. The address and phone number of the appealing party; and if the appealing party is a corporation, association or other group, the address and phone number of a contact person authorized to receive notices on the appealing party's behalf 3. A statement identifying the decision being appealed and the alleged errors in the decision, including any specific challenge to an MDNS. 4. The Notice of Appeal shall identify (a) the specific errors of fact or errors in application of the law in the decision being appealed; (b) the harm suffered or anticipated by the appellant, and (c) the relief sought. The scope of an appeal shall be Limited to matters or issues raised in the Notice of Appeal. 5. Appeal fee of $515 plus additional fees if review time exceeds 5 hours. V. APPEAL HEARINGS PROCESS Any administrative appeal regarding the Permit shall be conducted as an open record hearing before the Hearing Examiner based on the testimony and documentary evidence presented at the open record hearing. The Hearing Examiner's decision on the appeal is the City's final decision. Any party wishing to challenge the Hearing Examiner decision on this application must file an appeal pursuant to the procedures and time limitations set forth in RCW 36.70C. If no appeal of the Hearing Examiner decision is properly filed in Superior Court within such time limit, the Decision on this permit will be final. VI. INSPECTION OF INFORMATION ON THE APPLICATION Project materials including the application, any staff reports, and other studies related to the permits are available for inspection at the Tukwila Department of Community Development, 6300 Southcenter Blvd., Suite 100, Tukwila, Washington 98188 from Monday through Friday between 8:30 a.m. and 5:00 p.m. The project planner is Courtney Thomson, who may be contacted at (206) 431-2164 for further information. Property owners affected by this decision may request a change in valuation for their property tax purposes. Contact the King County Assessor's Office for further information regarding property tax valuation changes. The notice board must be removed at the expiration of the appeal period if no appeal is filed. Department of Community Development City of Tukwila CT Page 2 of 2 W:\Users\Courtney\L Files \L10-040 WCF Type 1\2010_08_16_NOD.doc 08/12/2010 STAFF REPORT TO THE DIRECTOR PREPARED August 12, 2010 NOTIFICATION: Public Notice is not required for a Type 1 application. FILE NUMBER: L10-040 APPLICANT: Sarah Telschow of RealCom Associates on behalf of Verizon Wireless PROPERTY OWNER: King County REQUEST: Approval of a Type 1 Wireless Communications Facility Permit to install one (1) new two -foot diameter microwave dish on existing pole and to add one (1) new equipment cabinet within the existing equipment enclosure. LOCATION: 18800 Orillia Road, APN: 3523049037 ASSOCIATED PERMITS: L99-0062, Permit for existing 60' monopole and two (2) antennas. L2000-012, Permit for four (4) additional antennas on existing monopole. D07-023, Relocation of antennas from middle platform to top platform was approved, but file was closed due to inactivity. L09-058, Installation of four (4) new panel antennas on existing pole and to move six (6) existing antennas to the vacant platform at the top of pole.. SEPA DETERMINATION: Exempt COMPREHENSIVE PLAN DESIGNATION: Tukwila Valley South (TVS) ZONE DESIGNATION: Tukwila Valley South (TVS) STAFF: Courtney Thomson, Planning Intern ATTACHMENTS: Construction Plans dated May 19, 2010 FINDINGS Vicinity/Site Information Project Description: The applicant is requesting approval of a Type 1 Wireless Facilities Permit to install one (1) two -foot diameter microwave dish on an existing 60 -foot tower and add one (1) new equipment cabinet within the existing equipment enclosure. The proposal does not increase the height of the existing tower or the size of the enclosure area. Existing Development: The Bow Lake Transfer Station is located on this site. An existing 60 -foot tall wireless communication monopole is located in the southwest corner of the site. The wireless communication facility contains ten (10) antennas, multiple equipment cabinets, and other ground equipment. Surrounding Land Uses: The property and all immediately surrounding properties are zoned Tukwila Valley South. The Bow Lake Transfer Station is located on this parcel and the parcel to the north. Other surrounding land uses in the area are primarily industrial lots with the exception of a golf facility. I-5 forms the western border of the site. Location Selection Tukwila Municipal Code (TMC) provides a hierarchy of appropriate locations within the City. Generally, co - locations and utilizing existing structures are favored over the development of new standalone WCF within the City. The applicant is proposing to attach additional antennas on an existing structure in a non-residential zone. General Requirements (TMC 18.58.070) The City provides general design standards for the placement of WCF within the City of Tukwila. The following are the general design standards for all WCF within the City: Table 1 General Design Project Project does Not Applicable Notes: Standards does comply not compl 1. Generators must comply with TMC 8.22 regarding noise. X The applicant has not proposed a generator. 2.Business License Requirement X Verizon already has a business license for this location. 3. Only safety signage must be placed on the WCF X No signs will be on site unless required by either the FCC or the FAA. 4. Accommodations for parking for maintenance personnel must be provided. X Existing on-site parking provides adequate parking for the existing facility. 5. Towers shall maintain a galvanized steel finish. X No changes have been proposed to the finish of the tower. CT Page 2 of 4 W:\Users\Courtney\L Files\L10-040 WCF Type 1\2010_08_12_staffreport.doc 08/12/2010 6. The design of all buildings and ancillary structures shall use materials, colors, textures, screening, and landscaping that will blend the tower facilities to the natural setting and built environment. Project Project does X No new buildings or ancillary structures have been proposed and no changes have been proposed for the existing buildings or ancillary structures. 7. Antennas shall have the same color scheme as the structure they are located on. X not comply Antennas and associated mounting hardware will be painted to match the monopole. 8. WCF poles and towers shall only have safety lights if required• by a government agency. X No tower lighting will be on site unless required by either the FCC or the FAA. 9. No advertising is permitted on WCF X No advertising is or will be on site. 10. Each service provider shall be limited to an equipment enclosure of 360 square feet. X The existing enclosure area will not be increased. Adding Antennas to Existing WCF Tower -Specific Development Standards (18.58.090) Table 2 Design Standards Project Project does Not Applicable Notes: does comply not comply 1. The height must not exceed what was approved under the original application to construct the tower, or it will be considered a Type 2 decision. X The applicant is not proposing to add height to the tower. 2. Antennas shall be painted to match the color scheme of the tower. X The antennas will be painted to match the monopole. 3. There is no limit on the number of antennas that may be located on an existing tower. X 4. Feed lines and cables shall be located within the tower, or shall be painted to match the tower. X The feed lines, coaxial cable, and associated mounting hardware will be painted to match the monopole. CT Page 3 of 4 W:\Users\Courtney\L Files\L10-040 WCF Type 1\2010_08_12_staffreport.doc 08/12/2010 5. A new cabinet shall be located within the equipment enclosure X One additional equipment cabinet will be installed within the existing equipment enclosure. that was approved as part of the original application, or it will require a Type 2 decision. 6. Setbacks shall not apply when an applicant installs new antennas on an existing X No new equipment is proposed and no changes to the existing equipment enclosure have been proposed. tower and uses an existing equipment enclosure. If the equipment enclosure is increased, it must meet setbacks. CONCLUSIONS 1. As demonstrated in Tables 1 and 2 the project meets all applicable development standards for the proposed type of WCF. 2. No noise will be generated from the new antennas, and the applicant is not proposing to install a generator. 3. The proposed project is in keeping with the goals and policies of the Comprehensive Land Use Policy Plan. 4. Verizon has a business license for this specific location as required by TMC 18.58.070 (2). The purpose of the business license requirement is so that City staff has contact information for the actual entity utilizing the WCF. DECISION The application for a Type 1 WCF is approved with no conditions. CT Page 4 of 4 08/12/2010 W:\Users\Courtney\L Files\L10-040 WCF Type 1\2010_08_12_staffreport.doc rage 1 of 2 • • DCD-Intern Intern - FW: Verizon Wireless SEA Orilla Road MW Addition From: "Sarah Telschow" <stelschow@realcomassoc.com> To: "DCD-Intern Intern" <cthomson@ci.tukwila.wa.us> Date: 08/12/2010 2:12 PM Subject: FW: Verizon Wireless_SEA Orilla Road_MW Addition August 12, 2010 Courtney: Please find the below e-mail from King County which acknowledges that they arc aware of Verizon Wireless's proposed construction activities at. this site location. Thanks Sarah Telschow Planner RealCom Associates LLC Office: (425) 274-4444 x114 Mobile: (206) 979-6268 Fax: (425) 274-4449 stelschow@realcomassoc.com VISIT OUR NEW WEBSITE: www.realcomassoc.com From: Paine, Tom [mailto:Tom.Paine@kingcounty.gov] Sent: Wednesday, August 11, 2010 11:17 AM To: Olivia Bazylewicz Cc: Fujii, Neil; Creegan, Tom Subject: RE: Verizon Wireless_SEA Orilla Road_MW Addition Hi Olivia, Yes King County is aware of the proposed equipment modification on the tower and does not believe there will be any conflicts with the ongoing construction project. Thanks, Tom Paine, S/WA Property Manager King C'ounty Real -state Services 500th,4venue, (&)om 500 Seattle, TO 98104 email tom.paine@kingcounty.gov P}'h: 206-296-0628 From: Olivia Bazylewicz [mailto:obaz@realcomassoc.com] Sent: Wednesday, August 11, 2010 10:34 AM To: Paine, Tom Subject: Verizon Wireless_SEA Orilla Road_MW Addition file://C:\temp\XPgrpwise\4C64014Btuk-mail6300-po 1001376F7617B391 \GW} 00002.H... 08/12/2010 • • Hello Tom, The Public Works Department at the City of Tukwila has requested you provide an e-mail assuring that there are no conflicts with the VZW modification and the now active Bow Lake TS construction project. As you know, VZW has its own driveway to access the site. We do not believe there will be any issues while constructing the upgrade. Can you please respond to this e-mail with your comments and outlook. Thank you, Olivia Bazylewicz RealCom Associates, LLC 14432 SE Eastgate Way, Suite 260 Bellevue, WA 98007 Desk: 425-274-4444 Ext: 118 Mobile: 253-653-9787 Fax: 425-274-4449 VISIT OUR NEW WEBSITE: www.realcomassoc.com file://C:\temp\XPgrpwise\4C64014Btuk-mail6300-po 10013 76F7617B391 \G W } 00002.H... 08/12/2010 City of Tukwila Department of Community Development File Number L10-040 LAND USE PERMIT ROUTING FORM TO: IQ Building Planning Public Works FireC'" F e�'� pt's Police Dept. Parks/Rec Project: Verizon Wireless - SEA Brisco/Orillia Rd Address: 18800 Orillia Rd S Parcel #3523049037 Date transmitted: 7-16-2010 Response requested by: 8-2-2010 Staff coordinator: Courtney Thomson Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60 -day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) Wireless Communications Faciliy Permit Installation of one two -foot microwave dish on an existing tower and installation of one new equipment cabinet. Plan check �o���j date 25\ Comments prepared by: V ^-\S \ 1 Update date: TO: City of Tukwila Department of Community Development RECEIVED JUL .19 YUtU TUKWILA PUBLIC WORKS File Number L10-040 LAND USE PERMIT ROUTING FORM Building . 01 Planning VIPubl c lNorks n Fire Dept. 101Police Dept. Parks/Rec Project: Verizon Wireless - SEA Brisco/Orillia Rd Address: 18800 Orillia Rd S Parcel #3523049037 Date transmitted: 7-16-2010 Response requested by: 8-2-2010 Staff coordinator: Courtney Thomson Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60 -day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) Wireless Communications Faciliy Permit Installation of one two -foot microwave dish on an existing tower and installation of one new equipment cabinet. 91,(3' lutn ma Cmms Plan check date: Comments 1 Update date: prepared by: JQ (o,4 ya. TO: City of Tukwila Department of Community Development File Number L10-040 LAND USE PERMIT ROUTING FORM r�B�ui►ding_ Planning fl Public Works 1❑1 Fire Dept. Police Dept. U Parks/Rec Project: Verizon Wireless - SEA Brisco/Orillia Rd Address: 18800 Orillia Rd S Parcel #3523049037 -Date transmitted: 7-16-2010 Response requested by: 8-2-2010 Staff coordinator: Courtney Thomson Date response received: REVIEWERS: Please specify how the attached plans conflict with your ADOPTED development regulations, including citations. Be specific in describing the types of changes you want made to the plans. When referencing codes, please identify the actual requirement and plan change needed. The Planning Division review does not supplant each department's ability to administer its own regulations and permits. However, project consistency at the Planning review stage is important to minimize significant later design changes. More than minimal design changes require further Planning Commission review, even if alteration is required to satisfy a City requirement. This further review is typically a minimum 60 -day process. Requirements based on SEPA (e.g., not required by an adopted development regulation) MUST identify the impact being mitigated, the policy basis for requiring mitigation, and the method used to calculate the mitigation required. Calculations of project impacts and the mitigation required (e.g., water capacity, road level of service analyses, or turning analyses) may be required of the applicant. COMMENTS (Attach additional comment sheets and/or support materials as needed.) Wireless Communications Faciliy Permit Installation of one two -foot microwave dish on an existing tower and installation of one new equipment cabinet. Plan check date: .7 �0-/a Comments Update date: prepared by: City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director NOTICE OF COMPLETE APPLICATION July 16, 2010 Ms. Sarah Telschow RealCom Associates 14432 SE Eastgate Way Suite #260 Bellevue, WA 98007 Subject: Wireless Tele-Communications Facility Permit (L10-040), 18800 Orillia Road Verizon Wireless - SEA Brisco / Orillia Road Dear Ms. Telschow: Your application for a Wireless Tele-Communications Facility Permit is considered complete on July 16, 2010 for the purposes of meeting state mandated time requirements. This determination of complete application does not preclude the ability of the City to require that you submit additional plans or information, if in our estimation such information is necessary to ensure the project meets the substantive requirements of the City or to complete the review process. This notice of complete application applies only to the permits identified above. It is your responsibility to apply for and obtain all necessary permits issued by other agencies. Please feel free to contact me with any questions at (206) 431-2164. Sincerely, -h,om ori Courtney Thomson Planning Intern cc. L10-040 CT Page 1 of 1 W:\Users\Courtney\L Files\L10-040 WCF Type 1\2010_07_16_complete.doc 07/16/2010 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax: 206-431-3665 CITY OF TUKWILA Department of Community Development WIRELESS TELE - 6300 Southcenter Boulevard, Tukwila, WA 98188 COMMUNICATION Telephone: (206) 431-3670 FAX (206) 431-3665 FACILITIES E-mail: tukplan@ci.tukwila.wa.us APPLICATION FOR STAFF USE ONLY Permits Plus Type P-WCF Planner: CA/Cr-1116c) 1.drrldon File Number: � 6q0 Application Complete (Date: -1-1 (0—)0 ) Project File Number: Application Incomplete (Date: Other File Numbers: NAME OF PROJECT/DEVELOPMENT: Verizon Wireless - SEA Brisco / Orilla Road LOCATION OF PROJECT/DEVELOPMENT: Give street address or, if vacant, indicate lot(s), block and subdivision, access street, and nearest intersection. 1.170 Orillia Road LIST ALL TAX LOT NUMBERS (this information may be found on your tax statement). 3523049037 DEVELOPMENT COORDINATOR : The individual who: • has decision making authority on behalf of the owner/applicant in meetings with City staff, • has full responsibility for identifying and satisfying all relevant and sometimes overlapping development standards, and • is the primary contact with the City, to whom all notices and reports will be sent. Name: RealCom Associates - Sarah Telschow Address: 14432 SE Eastgate Way, Suite 260 Phone: (425) 274-4444 ext. 114 FAX: (425) 274-4449 Date: 0 (p - 2 Z -(O RELCOM»uoo�a DOCUMENTATION TRANSMITTAL DATE: June 24, 2010 TO: City of Tukwila FROM: Sarah Telschow Planner RE: Verizon Wireless - SEA Brisco / Orilla Road Type I \VCF Permit. Application THE FOLLOWING DOCUMENTS HAVE BEEN ENCLOSED: One (1) Application Checklist. ENT (.5) WCF Application Form One (1) Project. Description One (1) Acoustical Report. Two (2) Structural Calculations One (1) 11" x 17" CD's Five (.5) Full Size CD's PURPOSE: If you have any questions and/or concerns about. the enclosed materials, please feel free to contact me at work (425)274-4444, by cellular (206) 979-6268, or via e-mail stelschow@realconlassoc.com. Thank you. RealCom Associates, LLC 14432 SE Eastgate Way, Suite 260 St Bellevue, Washington 98007St Phone (425) 274-4444 Fax (425) 274-4449 www.realcomassoc.com COMPLETE APPLICATION CHECKLIST The materials listed below must be submitted with your application unless specifically waived in writing the Department of Community Development. Please contact each Department if you feel that certain items are not applicable to your project and should be waived. Application review will not begin until it is determined to be complete. ADDITIONAL MATERIALS MAY BE REQUIRED. The initial application materials allow project review to begin and vest the applicant's rights. However, the City may require additional information as needed to establish consistency with development standards. City staff are available to answer questions about application materials at 206-431-3670 (Department of Community Development) and 206-433-0179 (Department of Public Works). Check items submitted with application Information Required. May be waived in unusual cases, upon approval of both Public Works and Planning APPLICATION MATERIALS: Items 1-9 are required for ALL Wireless Telecommunication Facilities. x 1. Application Checklist (1 copy) indicating items submitted with application. x 2. Completed Application Form and drawings (5 copies). X 3. Four sets of plans prepared by a design professional. The plans shall include a vicinity map, site map, architectural elevations, method of attachment, proposed screening, location of proposed antennas, and all other information which accurately depicts the proposed project. Minimum size is 8.5" by 11". Plans shall be no greater than 24" x 36". x 4. Application Fee: See attached Land Use Fee Schedule. X 5. Completed and notarized Affidavit of Ownership and Hold Harmless Permission to Enter Property (1 copy attached). N/A 6. SEPA Environmental Checklist. SEPA is not required when the facility: i) Is a microshell and is to be attached to an exiting structure that is not a residence or school and does not contain a residence or a school; ii) Includes personal wireless antennas, other than a microcell, and is to be attached to an existing structure (that may be an existing tower) that is not a residence or school and does not contain a residence or school, and the existing structure to which it is to be attached is located in a commercial, industrial, manufacturing, forest or agriculture zone; or iii) Involves constructing a personal wireless tower less than sixty feet in height that is located in a commercial, industrial, manufacturing, forest, or agricultural zone. X 7. A letter from the applicant describing the proposed project and describing compliance with the City's Code requirements. N/A 8. Sensitive Area studies and proposed mitigation (if required). X 9. If an outdoor generator is proposed, a report prepared by an acoustical engineer demonstrating compliance with TMC Chapter 8.22, "Noise". If the application requires a Type II review these additional items are needed: 10. Four sets of photo simulations that depict the existing and proposed view of the proposed facility; 11. Materials board for the screening material; 12. Landscaping plan; 13. Letter from a radio frequency engineer that demonstrates that the facility meets Federal requirements for allowed emissions; 14. If the facility is located within a residential zone, a report from a radio frequency engineer explaining the need for the proposed wireless communication facility at that location. Additionally, the applicant shall provide detailed discussion on why the wireless communication facility cannot be located within a commercial or industrial zone. If the application requires a Type IV review these additional items are needed: 15. A narrative responding to the criteria at TMC Section 18.58.060. 16. The radio frequency engineer report shall include a discussion of the information required under TMC Section 18.58.070. The report shall also explain why a tower must be used instead of any of the other location options outlined in Table A. 17. Engineering Plans for the proposed tower. 18. A vicinity map depicting the proposed extent of the service area. 19. A graphic simulation showing the appearance of the proposed tower and ancillary structures and ancillary facilities from five points within the impacted vicinity. Such points are to be mutually agreed upon by the Director of DCD and applicant. All plans and photo simulations shall include the maximum build -out of the proposed facility. 20. Evidence of compliance with Federal Aviation Administration (FAA) standards for height and lighting and certificates of compliance from all affected agencies. 21. Evidence that the tower has been designed to meet the minimum structural standards for wireless communication facilities for a minimum of three providers of voice, video or data transmission services, including the applicant, and including a description of the number and types of antennas the tower can accommodate. PUBLIC NOTICE MATERIALS: 22. Payment of a $365 notice board fee to FastSigns Tukwila or Provide a 4' x 4' public notice board on site within 14 days of the Department determining that a complete application has been received (see Public Notice Sign Specifications Handout). 23. Provide two (2) sets of mailing labels for all property owners and tenants (residents or businesses) within 500 feet of the subject property. Note: Each unit in multiple -family buildings—e.g. apartments, condos, trailer parks—must be included (see Public Notice Mailing Label Handout). Or See attached Land Use Fee Schedule for City of Tukwila to provide labels 24. If providing own labels King County Assessor's map(s) which shows the location of each property within 500 ft. of the subject lot. RECEIVED PROJECT DESCRIPTION JUN 2 4 2010 COMMUNITY DEVELOPMENT INTRODUCTION Verizon Wireless (here alter referred to as "Verizon") is a wireless telephone company operating throughout the United States of America. Verizon is licensed to operate in the United States by the Federal Communications Commission (FCC). This proposal describes the scope of the proposed project by providing specific information regarding the project: location, zoning, specifications, and required services. It is Verizon's desire to work with the City of Tukwila to ensure that. this project is consistent: with local ordinances and zoning regulations while providing wireless coverage to Verizon's customers and provide critical communication services for emergency, business, and personal use. Project Goals \The goal of the Verizon SEA Brisco / Orilla Road Site is to upgrade Verizon's existing network to provide better telephone service. Verizon intends to achieve these network goals consistent with all policies and ordinances of the City of Tukwila. Application Request Plan The applicant is requesting the following: ■ Type 1 Land Use Review TVcnizotn Wireless SEA Misty / Ori!!a Road Page 1 GENERAL PROJECT DESCRIPTION Project Overview The applicant, Verizon, proposes to modify an existing approved telecommunication facility at. 18700 Orillia Road Tukwila, Washington (Parcel Number 3.523049037). The proposed modification consists of the following: Add one (1) two foot (2') microwave dish and one (1) new equipment. cabinet. Facility Specifications ■ Facility Maintenance - The facility is generally serviced once a month. One (1) to two (2) employees are on site for an average of lour (4) hours of maintenance checks. This check is typically for preventive maintenance purposes. In the event of a problem, a crew is dispatched to the site immediately. ■ Microwave Dish - Verizon is proposing to add one (1) new two foot (2') microwave dish. GENERAL SITE ANALYSIS Zoning General Plan Designation The site is zoned Tukwila Valley South (TVS). Verizon's proposed telecommunication Iacility modifications require a "hype 1 Land Use Review according to Tukwila Municipal Code (TMC) 18.58.050: A. Applications will be reviewed based on the type of wireless communication facilities requested to be permitted. Each wireless communication facility requires the appropriate type of project permit review, as shomi in "liable A: Verizon Wireless EA Biisco / Ori/la Road Paget TABLE A Type of Permit Required, Based on Type of Wireless Communication Facility Zoning(1) Type of Facility Residential Commercial industrial Transmission tower co -location Type 1 Type 1 Type 1 Adding antennas to an existing tower Type 1(2) Type 1(Z Type 1(2) Utility pole co -location Type 2 Type 2 Type 2 Concealed building attached Type 2) Type 2() Type 1 Non -concealed building attached Type 2 Type 2 Type 1 New tower or waiver request Type 4 Type 4 Type 4 (1) Zoning for any private/ public property or right- of-way: ightofway: Residential — LDR, MDR, or HDR. Commercial — O, MUO, RCC, NCC, RC, RC14 TUC, C1 LI or TVS. Industrial LI, HI, MIC/L, or MIC/H. (2) Provided the height of the tower does not increase and the square footage of the enclosure area does not increase. (3) An applicant may request to install a non - concealed building attached facility, under TMC Section 18.58.150. Verizon is not proposing to add height to the dower and there is no proposed increase in size of the enclosure area. Accordingly, Verizon is requesting the review and approval of a Type 1 Land Use Review and Commercial Building Permit approval. Noise According to TMC 18.58.070: 1. Noise - Any facility that requires a generator or other device which will create noise must demonstrate compliance with TMC Chapter 8.22, "Noise". A noise report, prepared by an acoustical engineer, shall be submitted with any application to construct and operate a wireless communication facility that will have a generator or similar device. The City may require that the report be reviewed by a third party expert at the expense of the applicant. I/ei izoil Wireless SEA 13n'sco / Onl/ 1 Road Page 3 Verzion's equipment will meet all applicable noise standards. Please sec the enclosed Acoustical Report. Business License Requirement According to TMC 18.58.070: 2. Business license requirement - Any person, corporation or entity that operates a wireless communication facility avithin the City shall have a valid business license issued annually by the City. Any person, corporation or other business entity which owns a lower also is required to obtain a business license on an annual basis. Verizon has Idled for a business license for this site location. Signage According to TMC 18.58.070: 3. Signage - Only safety signs or those mandated by other government entities may be located on wireless communication facilities. No other types of sighs arc permitted on wireless communication facilities. No signs will be on-site unless required by either the FCC and/or FAA. Parking According to TMC 18.58.070: 4. Parking - Any application must demonstrate that there is sufficient space for temporal), parking for regulhu• maintenance of the proposed facility. Existing on-site parking provides adequate parking for the existing facility. Finish According to TMC 18.58.070: .5. Finish - A tower shall either maintain a galvanized steel finish or, subject to any applicable standards of the FAA or FCC, be painted a neutral color so as to reduce its visual obtrusiveness. The feed lines, coaxial cables, and associated mounting hardware will be painted to match the monopole to blend with the surrounding environment. Verizon Wireless SEA 13risco /Oiill a Road Page 4 Design According to TMC 18.58.070: 6. Design - The design of all buildings and ancillary structures shall use materials, colors, textures, screening and landscaping that will blend the tower facilities with the natural setting and built environment. The feed lines, coaxial cables, and associated mounting hardware will be painted to match the monopole to blend with the surrounding environment. Color According to TMC 18.58.070: 7. Color - A11 antennas and ancillary facilities located on building's or structures other than towers shall be of a neutral color that is identical to or closely compatible with the color of the supporting structure so as to make the antenna and ancillary facilities as visually unobtrusive as possible. The associated mounting hardware will be painted to match the monopole to blend with the surrounding environment. Lighting According to TMC 18.58.070: 8. Lig/sting. - Towers shall not be artificially lighted unless required by the FAA, FCC or other applicable authority. If lighting is required, the reviewing authority shall review the lighting alternatives and approve the design that would cause the least disturbance to the surrounding ;ureas. No strobe lighting of any type is permitted on any tower. No tower lighting will be on-site unless required by either the FCC and/or FAA. Advertising According to TMC 18.58.070: 9. Advertising- - No advertising is permitted at wireless communication facility sites or on any auncillary structure or facilities equipment compound. No advertising is or will be on-site. Vernon Wireless SEA Brice° / Olill r Road Page 5 Equipment Enclosure According to TMC 18.58.070: 10. Lquipmenl Linc%sure - Each applicant shall be limited to an equipment enclosure of 360 square Leet at each site. However, ibis restriction shall not apply to enclosures located within an existing commercial, industrial, residential or institutional building. No additional equipment area is needed. The additional equipment cabinet will be located within the existing equipment area. There are no proposed changes to the existing equipment enclosure size. Height According to TMC 18.58.090: 1. Heigbl - The height must not exceed what was approved under the original application to construct the tower. If the height shall exceed what was originally approved, approval as a 'Type 2 decision is required for any height which will be less than the maximum height of the zone. Verizon is not proposing to add height to the tower. Antenna Aesthetics According to TMC 18.58.090: 2. Antenna aesthetics - Antennas shall be painted to match the color scheme of the tower. The feed lines, coaxial cables, and associated mounting hardware will be painted to match the monopole to blend with the surrounding environment. Feed Lines and Coaxial Cables According to TMC 18.58.090: 3. Feed Kites and' coa.v.a/ cables - Feed lines and coaxial cables shall be located within the lower. Any exposed feed lines or coaxial cables (such as when extended out of the tower to connect to the antennas) must be painted to match the tower. The teed lines, coaxial cables, and associated mounting hardware will be painted to match the monopole to blend with the surrounding environment. lemon W0'eless SEA I3risco / Oii//a Road Page 6 • Cabinet Equipment According to TMC 18.58.090: 4. Cabinet equipment - A new cabinet shall be located within the equipment enclosure that was approved as pari of the original application. If the applicant wishes to expand the equipment enclosure from what was approved by the City or County under the previous application, the applicant shall seek a wireless communication facility (Type 2) application for only the equipment enclosure increase. No additional equipment arca is needed. The additional equipment cabinet will be located within the existing equipment arca. "There arc no proposed changes to the existing equipnhent enclosure size. Setbacks According to TMC 18.58.090: .5. Setbacks - Setbacks shall not apply when an applicant installs new antennas on an existing tower and uses an existing equipment enclosure. If the equipment enclosure is increased, it must meet setbacks. No additional equipment area is needed. The additional equipment cabinet will be located within the existing equipment arca. There arc no proposed changes to the existing equipment enclosure size. Existing Use The subject. area accommodates an existing telecommunication facility. Access/Circulation The site will be accessed by the existing right of entry. There are no traffic impacts associated with these types of facilities as they arc unmanned and require infrequent maintenance. Federal Requirements Vc- rizon's proposed telecommunication facility modification will meet or exceed current standards and regulations of the FAA, the FCC, and any other agency of tie Federal government with the authority to regulate towers and antennas. Verizon's site will conform to all FAA/FCC regulations, and because the maximum ERP is less than two thousand (2,000) watts and/or the height of the facility is greater than ten meters (10m), an environmental evaluation of radio frequency missions is exempted per CFR Title 47 Part 24, Subpart E. Verizon has a license from the FCC to provide wireless services in throughout. Washington State. i"erizon Wireless SLA BMisco / Oii// a Road Ewe 7 SSA' Stewart • Alt AOaoua June 14, 2010 Mr. Bert White LDC, Inc. 14201 NE 200th St, Suite 100 Woodinville, WA 98072 Re: Acoustical Report — Verizon SEA Orillia Rd S Site: 18700 Orillia Road S, Tukwila, WA 98188 Dear Bert, agnusylco This report presents a noise survey performed in the immediate vicinity of the proposed Verizon telecommunications facility at 18700 Orillia Road S in Tukwila, Washington. This noise survey extends from the proposed equipment to the nearest properties. The purpose of this report is to document the existing conditions and the impacts of the acoustical changes due to the proposed equipment. This report contains data on the existing and predicted noise environments, impact criteria and an evaluation of the predicted sound levels as they relate to the criteria. Ambient Conditions Existing ambient sound levels of the site were measured on June 8, 2010 with a Larson - Davis 2800B real-time spectrum analyzer sound level meter. Measurements were conducted as close to the proposed location as possible and the property lines in accordance with the State of Washington code for Maximum Environmental Noise Levels WAC 173-60- 020. The average ambient noise level was 71 dB(A), and the primary noise source was vehicle traffic on Interstate 5. The weather during the measurements was partly cloudy and the roads were dry. Code Requirements The site is located within the City of Tukwila Zoning jurisdiction on property with a TVS zoning designation. The receiving properties are all zoned TVS. Tukwila Municipal Code 8.22.020 defines TVS as being within an Industrial district. The proposed new equipment consists of equipment support cabinets, which are expected to run 24 hours a day. Under Tukwila Municipal Code 8.22.040 noise from equipment on a within an Industrial district is limited as follows: Industrial District Receiver: Noise is limited to 70 dB(A) 24 hours a day. SSA Acoustics, LLP 222 Etruria Street, Ste 100 Seattle, Washington 98109 t. 206.839.0819 f. 206.839.0824 Verizon Wireless SEA Orillia Rd S Predicted Equipment Sound Levels 24 -Hour Operation Equipment The proposed equipment includes one Purcell SFX42BAX Microwave cabinet. According to manufacturer data, the produces a sound pressure level of 73 dB(A) at 5 feet. The nearest receiving property is 200 feet southeast of the equipment location. The predicted sound level at the nearest property is shown below in Table 1 below. Table 1 Application Factors and Predicted Noise Levels Proposed Equipment Line Application Factor Southeast 1 Combined Sound Pressure Level at 5 ft. (dB(A)), Lp1 73 2 Distance Factor (DF) Inverse -Square Law (Free Field): DF = 20Iog (d1/d2) -32 (200 ft) 3 New Equipment Sound Pressure Level at Receiver, Lpr (Add lines 1 and 2) 41 As shown in Table 1, the sound pressure level from the proposed cabinet at the nearest receiving property is 41 dB(A), which meets the 70 dB(A) code limit. Please contact us if you have any questions or require further information. Sincerely, SSA Acoustics, LLP Erik Miller -Klein Acoustical Consultant Page 2 wq� City of Tukwila 5 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us RECEIPT Parcel No.: 3523049037 Address: 18800 ORILLIA RD S TUKW Suite No: Applicant: VERIZON WIRELESS -SEA BRISCO/ORILLIA RD Permit Number: L10-040 Status: PENDING Applied Date: 06/24/2010 Issue Date: Receipt No.: R10-01152 Initials: TLS User ID: 1670 Payment Amount: $265.00 Payment Date: 06/24/2010 02:58 PM Balance: $0.00 Payee: SARAH TELSCHOW TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1857 265.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts ZONING/SUBDIVISION 000.345.810 Total: $265.00 265.00 AE�'F QED doc: Receir -06 Printed: 06-24-2010 May 17, 2010 RealCom Associates, LLC Attn: Olivia Bazylewicz 14432 SE Eastgate Way, Suite 260 Bellevue, WA 98007 RE: Verizon Wireless. SEA Orillia Road 60' Monopole 18700 Orillia Rd S. Tukwila, WA 98188 Dear Olivia: RECEIVED JUL 19 'lU1U TUKWILA PUBLIC WORKS THE CIYILENGINEERING GROUP Cbill in'erti;al i I'ufra3't'ri : li:es d`e.n'ti'al; We are pleased to submit our report for the structural analysis of the monopole at SEA Orillia Road in Tukwila with the addition of the proposed microwave antenna as aper your request. The 60' monopole with the proposed antenna loading will conform to the requirements of TIA-222-Gfor 85 mph'basic wind speed and 30 mph wind speed in; combination with 1/4" radial ice. The strength based review of the tower resulted in a maximum stress level of 25 percent of the members design capacity. The foundation was reviewed and found to be adequate with the proposed antenna loading. Should you have any questions or wish to discuss any aspect of this report, please do not hesitate to contact us. Sincerely, LDC, Inc. Ryan Anderson, P.E. Project Engineer .inae.r.ing._,Aj3'1 the_..Sa_a_n_da_r:d___._ o' 0 u u: J • R1 030 CV N CO w co 0 co fV 0 O co 01 3 T4201.,NE.200th Street, #TOO May 17, 2010 Structural Analysis Verizon Wireless 60' Monopole 18700 OriIlia Rd S. Tukwila, WA 98188 I. Introduction LD THE,CIYIC ENGINEERING.GROUP Co m nserci a,i, I 'I.nfrast'rudu-re'. Resi`de:nti_aI. At the request of RealCom Associates, we have performed:a structural feasibility review for the addition of.a microwave antenna to an existing Verizon. Wireless 60' monopole located in Tukwila, Washington. A finite element analysis was completed' in conformance with,the current design standard, TIA-222-G, "Structurat•Standard for Antenna Supporting Structures and Antennas" with the following site specific design conditions: Basic Wind Speed: 85 mph Radial Ice: 1/4" w/ 30 mph Wind Speed Tower Structural Class: II Topographic Category: 1 'Exposure Category: C The monopole was designed ;by Paul J. Ford and :Company and fabricated. by Summit Manufacturing, iLLC in 1999. The design drawings detail the 18 -sided, 60' tall monopole with a 28.1" base diameter and i/a" thick walls tapering to a 21.1" diameter at 32'. The lower section is slip jointed with a 3' splice 'to the upper section. The upper section has 3/16" thick walls and tapers to a top diameter of 16.5''. Based on a visual inspection performed by LDC on May 12, 2010, the monopole appears free of visible structural damage and corrosion. Geometry, .member sizes and additional proposed antennas were obtained from the structural calculations by Chi.S. Lee, P.E., S.E. dated June 21, 2007. The existing antenna layout was confirmed by LDC in the field prior to completion of this report. The proposed microwave addition is detailed in the Site Modification Request dated April 15, 2010. This analysis evaluated the adequacy of the monopole based on length, cross sectional properties and steel grade. Antenna mount attachment details and installation recommendations are to be'provided.by the manufacturer. II. Antenna and Transmission Line Loading Elev Appurtenance Projected Area Dead Load Status 58' (8) Panel Antennas 56.8 sq ft 127 lbs Existing 53' (1) 2' MW Antenna 3.2 sq ,ft 27 lbs Proposed 48' (6) Panel Antennas 38.6 sq ft 185 lbs Existing 38' 1 -Empty Platform 25.0 sq ft 1,000 lbs Existing E 0 u 0. 0 0 .J CO N COvt N a: CO 0 CO fV ry. 0 CO III. Results Tower Member Stress Levels Elevation Pole 60' to 32' 0.43 32' to 0' 0.66 -Stress levels below 1.00 are within the acceptable limit. Foundation Loads Base Reactions Original Design Loading Proposed Loading Overturning Moment 494 kip -ft 480 kip -ft Shear 10.6 kips 10.2 kips IV. Conclusions and Recommendations 1. The 60'-0" monopole with the proposed antenna loading conforms to the requirements of TIA-222-G for 85 mph basic wind speed and 30 mph wind speed with 1/4" radial ice. The monopole is structurally adequate with the existing and proposed antenna loading as previously listed in this report. This conclusion is based on the information provided by RealCom Associates. If discrepancies exist between the report loading and the actual existing or proposed loading, LDC should be notified immediately. 2. The existing foundation is structurally adequate under the existing and proposed loading as listed in this report. Foundation information was derived from the original foundation design by Paul J. Ford and Company dated November 3, 1999. The original design base reactions exceed the proposed base reactions as calculated with the additional antenna loading. The foundation embedment depth was also reviewed in conformance with the 2006 IBC for a nonconstrained condition and determined adequate. Please contact the undersigned if there are any questions. Ryan Anderson, P.E. Project Engineer Engineering ABOVE the Standard LDC, Inc. • Commercial • Infrastructure • Residential • N o N / 8. 2 til 18 o o S o.. N A572-65 2302.3 1086.6 0 Y N G 47.5 N N o N 0 Length (6) Number of Sides Thickness On) 2 cod. 3 O 1-- o s Ql o (0 cu R a 6 3 60.0 ft 32.0 ft 0.0 11 n 4-1 DESIGNED APPURTENANCE LOADING TYPE ELEVATION TYPE ELEVATION Valmont 13' Platform wlRails 57.5 HP2-18 52 7131.20.33.05 57.5 ALP 9212 wlMount Pipe 47.5 7131.20.33.05 57.5 ALP 9212 w/MouM Pipe 47.5 7131.20.33.05 57.5 RR65-19 47.5 7131.20.33.05 57.5 RR65-19 47.5 7131.20.33.05 57.5 RR65-19 47.5 .7131.20.33.05 57.5 RR65-19 47.5 7131.20.33.05 57.5 Valmont 13' Platform wlRails 47.5 7131.20.33.05 57.5 Valmont 13' Platform w/Rails 38 MATERIAL STRENGTH GRADE Fy Fu GRADE 1 Fy Fu A572-85 65 ksl 80 681 O SHEAR 1097 lb TOWER DESIGN NOTES 1. Tower is located in King County, Washington. 2. Tower designed for Exposure C to the TIA-222-G Standard. 3. Tower designed for a 85 mph basic wind in accordance with the TIA-222-G Standard. 4. Tower is also designed for a 30 mph basic wind with 0.25 in ice. Ice is considered to increase jn thickness with height. 5. Deflections are based upon a 60 mph wind. 6. Weld together tower sections have flange connections. 7. Connections use galvanized A325 bolts, nuts and locking devices. Installation per TIA/EIA-222 and AISC Specifications. '8. Tower members are "hot dipped" galvanized in accordance with ASTM A123 and ASTM A153 Standards. 9. Welds are fabricated with ER -70S-6 electrodes. 10. TOWER RATING: 75.6% AXIAL 16374 lb MOMENT 50 kip -ft TORQUE 0 kip -ft 30 mph WIND - 0.25 in ICE AXIAL 121281b SHEAR 10267 /b MOMENT 480 kip -ft TORQUE 2 kip -ft REACTIONS - 85 mph WIND LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 '°b SEA Orillia Road Pr°lace 60' Monopole client Verizon Wireless Drawn by: randerson Code: TIA-222-G Date: 05/14/10 Path: Pi101A T 10402 Vwfm- SEA Q,Ah RaeaAt,EmMMSEA Orilla REM -0.n App'd: Scale: NTS Dwg No. E-1 .-r 0 es i w TIA-222-G - 85 mph/30 mph 0.25 in Ice Exposure C Vx Vz Global Mast Shear (Ib) 5000 5000 Job' SEA Orillia Road Project 60' monopole Client Verizon Wireless 32.00 "m'd: Code: TIA-222-G 13ete:05/14/10 ale NTS Ppb'vv0t0T.iemmomivertm.sEAaaemaamomefmheanSFaonm.aana...DWONo.E-4 -1 0.09 10000 Maximum Values Mx Mz Global Mast Moment (kip -ft) 00 0 500 60 00 32.00 0.00 500 LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 808-1869 FAX: (425) 482-2893 Job' SEA Orillia Road Project 60' monopole Client Verizon Wireless Drawn by: randerson "m'd: Code: TIA-222-G 13ete:05/14/10 ale NTS Ppb'vv0t0T.iemmomivertm.sEAaaemaamomefmheanSFaonm.aana...DWONo.E-4 Deflection (in) 5 10 0 10 TIA-222-G - Service - 60 mph Maximum Values 0 Tilt (deg) 05 1 I I I I I I I I I I I I I I I I I I I I I 1 I I I I I I I I I I I I I I I I I I I I I I I I I I 1__L__I_ I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 1__L I 1 1 I I 1 1 I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 0 05 0 Twist (deg) 0.05 01 50 00 I I I I I I I I I I I I I I I I I I 1 L I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I 32.00 0 .00 0 0.05 01 LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 bb: SEA Orillia Road Project: 60' Monopole Client Verizon Wireless Drawn by: randerson code: TIA-222-G Date: 05/14/10 Path: P1701111, Tebmn110E112 Veton • SEA Orel%Ro.C9eUFnoh.el4F.A Q1114 ee 11A -GSL App'd: Scale: NTS, Dwg No. E-5', �7� RISATower LDC, Inc. 14201 NE200thStSuite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 1 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Tower input Data There is a pole section. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in King County, Washington. Basic wind speed of 85 mph. Structure Class II. Exposure Category C. Topographic Category 1. Crest Height 0.00 ft. Nominal ice thickness of 0.25 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 30 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 60 mph. Weld together tower sections have flange connections.. Connections use galvanized A325 bolts, nuts and locking devices. Installation per TIA/EIA-222 and AISC Specifications.. Tower members are "hot dipped" galvanized in accordance with ASTM A123 and ASTM A153 Standards.. Welds are fabricated with ER -70S-6 electrodes.. A non-linear (P -delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feedline supports, and appurtenance mounts are not considered. Options Consider Moments - Legs I/ Consider Moments - Horizontals 11 Consider Moments - Diagonals Use Moment Magnification Use Code Stress Ratios Use Code Safety Factors - Guys Escalate Ice Always Use Max Kz Use Special Wind Profile Include Bolts In Member Capacity Leg Bolts Are At Top Of Section Secondary Horizontal Braces Leg Use Diamond Inner Bracing (4 Sided) Add IBC .6D+W Combination J J Distribute Leg Loads As Uniform Assume Legs Pinned Assume Rigid Index Plate Use Clear Spans For Wind Area Use Clear Spans For KL/r Retension Guys To Initial Tension Bypass Mast Stability Checks Use Azimuth Dish Coefficients Project Wind Area of Appurt. Autocalc Torque Arm Areas SR Members Have Cut Ends Sort Capacity Reports By Component Triangulate Diamond Inner Bracing Treat Feedline Bundles As Cylinder Use ASCE 10 X -Brace Ly Rules Calculate Redundant Bracing Forces Ignore Redundant Members in FEA SR Leg Bolts Resist Compression All Leg Panels Have Same Allowable Offset Girt At Foundation Consider Feedline Torque Include Angle Block Shear Check L Poles . J Include Shear -Torsion Interaction Always Use Sub -Critical Flow Use Top Mounted Sockets Tapered Pole Section Geometry RISATower ower LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 2 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Section Elevation Section Splice Number Top Bottom Wall Bend Pole Grade Length Length of Diameter Diameter Thickness Radius ft ft ft Sides in in in in Ll 60.00-32.00 28.00 3.00 18 16.50 22.10 0.19 0.75 A572-65 (65 ksi) L2 32.00-0.00 35.00 18 21.12 28.10 0.25 1.00 A572-65 (65 ksi) Tapered Pole Properties Section Tip Dia. Area rn tn2 1 in' r C 1/C J It/Q rn to 1n3 inr ,n in w/t LI 16.75 9.73 327.21 22.44 13.08 793.14 L2 22.06 16.56 911.80 28.53 22.10 2165.51 5.79 8.38 39.04 654.85 4.87 2.57 13.687 7.78 11.23 70.65 1587.32 6.54 3.56 18.929 7.41 10.73 84.97 1824.81 8.28 3.28 13.111 9.89 14.27 151.70 4333.87 11.05 4.51 18.022 Tower Gusset Gusset Gusset Grade Adjust. Factor Adjust. Weight Mult. Double Angle Double Angle Elevation Area Thickness Al Factor • Stitch Bolt Stitch Bolt (per face) A, Spacing Spacing Diagonals Horizontals ft ft' in in in LI 60.00-32.00 L2 32.00-0.00 Monopole Base Plate Data Base Plate Data Base plate is square Base plate is grouted Anchor bolt grade Anchor bolt size Number of bolts Embedment length 1', Grout space Base plate grade Base plate thickness Bolt circle diameter Outer diameter Inner diameter Comer clippled Base plate type J A615-75 2.25 in 4 120.00 in 3 ksi 3.00 in A633-60 2.50 in 33.42 in 32.00 in 18.00 in 2.50 in Plain Plate Feed Line/Linear Appurtenances - Entered As Area Description Face Allow Component or Shield Type Leg Placement ft Total Number CAAA ft'/ft Weight klf LDF5-50A (7/8 FOAM) C No Inside Pole 58.00 - 0.00 8 No Ice 0.00 0.00 1/2" Ice 0.00 0.00 LDF5-50A (7/8 FOAM) C No Inside Pole 48.00 - 0.00 12 No Ice 0.00 0.00 RISATower LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 3 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Description Face Allow Component or Shield Type Leg Placement ft Total Number CAAA jt'/fl Weight 1/2" Ice 0.00 LDF5-50A (7/8 FOAM) C No Inside Pole 53.00 - 0.00 2 No Ice 0.00 1/2" Ice 0.00 klf 0.00 0.00 0.00 Feed Line/Linear Appurtenances Section Areas Tower Tower Section Elevation ft Face AR AF CAAA CAAA In Face Out Face fr2 f12 f12 It2 Weight Ib L I 60.00-32.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 0.000 145.86 D 0.000 0.000 0.000 0.000 0.00 L2 32.00-0.00 A 0.000 0.000 0.000 0.000 0.00 B 0.000 0.000 0.000 0.000 0.00 C 0.000 0.000 0.000 0.000 232.32 D 0.000 0.000 0.000 0.000 0.00 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Section Tower Elevation ft Face Ice or Thickness Leg in AR AF Its ft' CAAA CAAA In Face Out Face It' f2 L1 60.00-32.00 A 0.516 0.000 B 0.000 C 0.000 D 0.000 L2 32.00-0.00 A 0.464 0.000 B 0.000 C 0.000 D 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 Weight lb 0.00 0.00 145.86 0.00 0.00 0.00 232.32 0.00 Shielding Factor Ka Tower Section Feed Line Record No. Description Feed Line Segment Elev. K No Ice K Ice Discrete Tower Loads Description Face Offset Offsets: Azimuth Placement or Type Horz Adjustment Leg Lateral Vert ft ft ft ft CAAA CAAA Weight Front Side f1 It' lb Valmont 13' Platform w/Rails C None 0.0000 38.00 No Ice 53.00 53.00 2000.00 1/2" Ice 68.00 68.00 3000.00 RISA 'ower LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 4 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Description Face Offset Offsets: Azimuth Placement or Type Horz Adjustment Leg Lateral Vert ft ft ft ft CAAA CAAA Weight Front Side ft2 ftp lb Valmont 13' Platform w/Rails C None 0.0000 47.50 No Ice 53.00 53.00 2000.00 1/2" Ice 68.00 68.00 3000.00 Valmont 13' Platform w/Rails C None 0.0000 57.50 No Ice 53.00 53.00 2000.00 1/2" Ice 68.00 68.00 3000.00 7131 20 33 05 A From Leg 4 00 0 0000 57 50 No Ice 7.11 4.23 15.90 -6.00 1/2" Ice 7.46 4.52 66.30 1.00 7131.20 33 05 A From Leg 4.00 0.0000 57 50 No Ice 7.11 4.23 15.90 -2.00 1/2" Ice 7.46 4.52 66.30 1.00 7131 20 33.05 A From Leg 4 00 0 0000 57 50 No Ice 7.11 4.23 15.90 2.00 1/2" Ice 7.46 4.52 66.30 1.00 7131 20 33 05 A From Leg 4.00 0.0000 57.50 No Ice 7 11 4 23 15.90 6.00 1/2" Ice 7.46 4.52 66.30 1.00 7131 20 33 05 C From Leg 4 00 0.0000 57 50 No Ice 7 11 4 23 15.90 -6.00 1/2" Ice 7.46 4.52 66.30 1.00 7131.20.33.05 C From Leg 4.00 0.0000 57.50 No Ice 7.11 4.23 15.90 -2.00 1/2" Ice 7.46 4.52 66.30 1.00 7131.20.33.05 C From Leg 4.00 0.0000 57.50 No Ice 7.11 4.23 15.90 2.00 1/2" Ice 7.46 4.52 66.30 1.00 7131.20.33.05 C From Leg 4.00 0.0000 57.50 No Ice 7.11 4.23 15.90 6.00 1/2" Ice 7.46 4.52 66.30 1.00 ALP 9212 w/Mount Pipe A From Leg 4.00 0.0000 47.50 No Ice 6.68 7.71 46.50 -6.00 1/2" Ice 7.48 8.96 109.88 1.00 ALP 9212 w/Mount Pipe A From Leg 4.00 0.0000 47.50 No Ice 6.68 7.71 46.50 6.00 1/2" Ice 7.48 8.96 109.88 1.00 RR65-19 B From Leg 4.00 0 0000 47 50 No Ice 5 87 2 75 23.00 -6.00 1/2" Ice 6.32 3.23 51.51 1.00 RR65-19 B From Leg 4.00 0 0000 47 50 No Ice 5 87 2 75 23.00 6.00 1/2" Ice 6.32 3.23 51.51 1.00 RR65-19 C From Leg 4.00 0 0000 47 50 No Ice 5 87 2 75 23.00 -6.00 1/2" Ice 6 32 3 23 51 51 1.00 RR65-19 C From Leg 4.00 0.0000 47.50 No Ice 5.87 2.75 23.00 6.00 1.00 1/2" Ice 6.32 3.23 51.51 Dishes RISATovell° LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 5 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Description Face Dish Offset Offsets: Azimuth 3 dB Elevation Outside or Type Type Horz Adjustment Beam Diameter Leg Lateral Width Vert ft ft ft Aperture Weight Area ft' lb HP2-18 A Paraboloid From 2.00 0.0000 52.00 2.00 w/Shroud (HP) Leg 0.00 0.00 No Ice 1/2" Ice 3.14 27.00 3.41 44.49 Tower Pressures - No Ice Gy = 1.100 Section Elevation ft z .ft Kz 4, psf AG fta F a c e AF ft2 AR ft2 Arg ft2 Leg % CAAA In Face ft: CAAA Out Face ft2 LI 60.00-32.00 45.32 1.071 19 45.728 A 0.000 45.728 45.728 100.00 0.000 0.000 0.000 0.000 B 0.000 45.728 B 100.00 0.000 0.000 100.00 0.000 0.000 C 0.000 45.728 100.00 0.000 0.000 100.00 0.000 0.000 D 0.000 45.728 100.00 0.000 0.000 L2 32.00-0.00 15.70 0.857 16 67.454 A 0.000 67.454 67.454 100.00 0.000 0.000 0 000 70 207 70 207 100 00 0.000 13 0.000 67.454 100.00 0.000 0.000 B 0.000 70.207 100.00 C 0.000 67.454 100.00 0.000 0.000 C 0.000 70.207 D 0.000 67.454 100.00 0.000 0.000 Tower Pressure - With Ice Gy = 1.100 Section Elevation ft z ft Kz qs psf tz in AG ft' F a c e AF ft' AR ft' Akg ft' Leg % CAAA In Face ft' CAAA Out , Face ft' L 160.00-32.00 45.32 1.071 2 0.52 48.137 A 0.000 48.137 48.137 100.00 0.000 0.000 B 0.000 48.137 100.00 0.000 0.000 C 0.000 48.137 100.00 0.000 0.000 D 0.000 48.137 100.00 0.000 0.000 L2 32 00-0 00 15 70 0 857 2 0 46 70.207 A 0 000 70 207 70 207 100 00 0.000 0.000 B 0.000 70.207 100.00 0.000 0.000 C 0.000 70.207 100.00 0.000 0.000 D 0.000 70.207 100.00 0.000 0.000 Tower Pressure - Service Gy =1.100 Section Elevation ft z ft Kz qt psf AG f? F a c e AF f1 AR ft2 Aig f2 Leg % CAAA In Face f12 CAAA Out Face ft: LI 60.00-32.00 45.32 1.071 8 45.728 A 0.000 45.728 45.728 100.00 0.000 0.000 SA Towe%" LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 6 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Section Elevation ft z ft Kz qz psf AG ft2 F a c e AF f12 AR ft2 Al„ ft2 Leg % CAAA In Face ft2 CAAA Out Face ft-- Ctrl. Face L 1 145.86 1086.59 A B 0.000 45.728 1 100.00 0.000 0.000 0.02 D 60.00-32.00 C 0.000 45.728 100.00 0.000 0.000 D 0.000 45.728 0.65 100.00 0.000 0.000 L2 32.00-0.00 15-70 0.857 7 67.454 A 0 000 67.454 67 454 100.00 0.000 0.000 1 45.728 B 0.000 67.454 A 100.00 0.000 0.000 1 1 67.454 754.31 0.02 C 0.000 67.454 100.00 0.000 0.000 1 1 67.454 D 0.000 67.454 100.00 0.000 0.000. Tower Forces - No Ice - Wind Normal To Face Section Elevation ft Add Weight lb Self Weight Ib F a c e e CF q: psf DF DR AE fl2 F lb w kif Ctrl. Face L 1 145.86 1086.59 A 1 0.65 19 1 1 45.728 615.52 0.02 D 60.00-32.00 B 1 0.65 1 1 45.728 C 1 0.65 1 1 45.728 D 1 0.65 1 1 45.728 L2 32.00-0.00 232.32 2302.31 A 1 0.65 16 1 1 67.454 754.31 0.02 D B 1 0.65 1 1 67.454 C 1 0.65 1 1 67.454 D 1 0.65 1 1 67.454 Sum Weight: 378.18 3388.89 OTM 39.74 1369.83 kip -ft Tower Forces - No Ice - Wind 45 To Face Section Elevation ft Add Weight Ib Self Weight Ib F a c e e CF q: psf DF DR AE ft2 F lb w klf Ctrl. Face L1 145.86 1086.59 A 1 0.65 19 1 1 45.728 615.52 0.02 D 60.00-32.00 B 1 0.65 1 1 45.728 C 1 0.65 1 1 45.728 D 1 0.65 1 1 45.728 L2 32.00-0.00 232.32 2302.31 A 1 0.65 16 1 1 67.454 754.31 0.02 D B 1 0.65 1 1 67.454 C I 0.65 1 1 67.454 D 1 0.65 1 1 67.454 Sum Weight: 378.18 3388.89 OTM 39.74 1369.83 kip -ft Tower Forces With Ice Wind Normal To Face RISATower LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 7 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Section Elevation ft Add Weight Ib Self Weight ib F a c e e CF q: psf DF DR AE ft' F lb w klf Ctrl. Face LI 145.86 1255.51 A 1 1.2 2 1 1 48.137 149.01 0.01 D 60.00-32.00 B 1 1.2 1 1 48.137 C 1 1.2 1 1 48.137 D 1 1.2 1 1 48.137 L2 32.00-0.00 232.32 2550.76 A 1 1.2 2 1 1 70.207 180.55 0.01 D B 1 1.2 1 1 70.207 C 1 1.2 1 1 70.207 D 1 1.2 1 1 70.207 Sum Weight: 378.18 3806.27 OTM 9.59 kip -ft 329.55 Tower Forces - With Ice - Wind 45 To Face Section Elevation ft Add Weight 1b Self Weight 1b F a c e e ' CF q: psf DF DR AE ft' F lb w klf Ctrl. Face L I 145.86 1255.51 A 1 1.2 2 1 1 48.137 149.01 0.01 D 60.00-32.00 B 1 1.2 1 1 48.137 C 1 1.2 1 1 48.137 D 1 1.2 1 1 48.137 L2 32.00-0.00 232.32 2550.76 A 1 1.2 2 1 1 70.207 180.55 0.01 D B 1 1.2 1 1 70.207 C 1 1.2 1 1 70.207 D 1 1.2 1 1 70.207 Sum Weight: 378.18 3806.27 OTM 9.59 kip -ft 329.55 Tower Forces - Service - Wind Normal To Face Section Elevation ft Add Weight ib Self Weight ib F a c e e CF q: psf DF DR AE ft' F lb w klf Girl. Face L 1 145.86 1086.59 A 1 0.65 8 1 1 45:728 274.41 0.01 D 60.00-32.00 B 1 0.65 1 1 45.728 C 1 0.65 1 1 45.728 D 1 0.65 1 1 45.728 L2 32.00-0.00 232.32 2302.31 A 1 0.65 7 1 1 67.454 336.29 0.01 D B 1 0.65 1 1 67.454 C 1 0.65 1 1 67.454 D 1 0.65 1 1 67.454 Sum Weight: 378.18 3388.89 OTM 17.72 610.70 kip -ft Tower Forces - Service - Wind 45 To Face RISATower LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 8 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Section Elevation ft Add Weight 1b Self Weight lb F a c e e CF q= psf DF DR AR ft' F lb w klf Ctrl. Face LI 145.86 1086.59 A 1 0.65 8 1 1 45.728 274.41 0.01 D 60.00-32.00 Total Weight B 1 0.65 -0.37 1 I 45.728 -259.56 -6399.70 -292.33 15.26 -0.37 C 1 0.65 -4358.32 1 I 45.728 Wind 90 deg - No Ice 6411.35 269.18 15.34 -292.51 D 1 0.65 1 1 45.728 Total Weight Ice 14329.24 L2 32.00-0-00 232-32 2302.31 A 1 0 65 7 1 1 67.454 33629 0.01 D 753.33 -754.73 B 1 0.65 Wind 90 deg - Ice 1 1 67.454 1.11 -47.78 -0.17 Total Weight 10106.27 C 1 0.65 1 1 67.454 -2853.12 -130.53 6.84 -0.16 Wind 45 deg - Service D 1 0.65 -87.33 I 1 67.454 2858.31 120.00 6.64 Sum Weight: 378.18 3388.89 OTM 17.72 610.70 kip -ft Force Totals Load Case Vertical Forces Ib Sum of Forces X lb Sum of Forces Z Ib Sum of Overturning Moments, M kip -ft Sum of Overturning Moments, Al, kip ft Sum of Torques lop -ft Leg Weight 3388.89 Bracing Weight 0.00 Total Member Self -Weight 3388.89 -0.37 0.06 Total Weight 10106.27 -0.37 0.06 ' Wind 0 deg - No Ice -259.56 -6399.70 -292.33 15.26 -0.37 Wind 45 deg - No Ice 4347.97 -4358.32 -196.92 -195.96 -1.11 Wind 90 deg - No Ice 6411.35 269.18 15.34 -292.51 -1.15 Member Ice 417.37 Total Weight Ice 14329.24 -0.85 0.13 Wind 0 deg - Ice -32.14 -1096.32 -48.68 2.03 -0.05 Wind 45 deg - Ice 753.33 -754.73 -33.45 -32.39 -0.16 Wind 90 deg - Ice 1097.90 33.45 1.11 -47.78 -0.17 Total Weight 10106.27 -0.37 0.06 Wind 0 deg - Service -115.72 -2853.12 -130.53 6.84 -0.16 Wind 45 deg - Service 1938.41 -1943.03 -88.00 -87.33 -0.50 Wind 90 deg - Service 2858.31 120.00 6.64 -130.38 -0.51 Load Combinations Comb. No. Description 1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg - No Ice 3 0.9 Dead+1.6 Wind 0 deg - No Ice 4 1.2 Dead+1.6 Wind 45 deg - No Ice 5 0.9 Dead+1.6 Wind 45 deg - No Ice 6 1.2 Dead+1.6 Wind 90 deg - No Ice 7 0.9 Dead+1.6 Wind 90 deg - No Ice 8 1.2 Dead+1.0 Ice+1.0 Temp 9 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 10 1.2 Dead+1.0 Wind 45 deg+1.0 Ice+1.0 Temp 11 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp RI" �.f>� Tower LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 9 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Comb. No. Description 12 Dead+Wind 0 deg - Service 13 Dead+Wind 45 deg - Service 14 Dead+Wind 90 deg - Service Maximum Member Forces Section No. Elevation ft Component Type Condition Gov. Load Comb. ib Axial Major Axis Minor Axis Moment Moment kip ft kip -%t L 1 60 - 32 Pole Max Tension 9 0.02 Max. Compression 8 -12865.65 Max. Mx 6 -8593.95 Max. My 2 -8594.73 Max. Vy 6 9235.09 Max. Vx 2 -9216.18 Max. Torque 7 L2 32 - 0 Pole Max Tension Max. Compression Max. Mx Max. My Max. Vy Max. Vx Max. Torque -0.00 -0.00 0.15 0.95 -136.89 -9.92 10.13 137.09 -136.89 -9.92 10.13 137.09 1.83 1 0.00 0.00 0.00 8 -16373.79 0.15 0.94 6 -12117.96 -478.85 -25.33 2 -12117.99 25.03 478.38 6 10269.35 -478.85 -25.33 2 -10250.70 25.03 478.38 7 1.83 Maximum Reactions Location Condition Gov. Load Comb. Vertical 1b Horizontal, X Horizontal, Z lb ib Pole Max. Vert 8 16373.79 -0.04 -0.25 Max. H■ 3 9095.65 415.30 10239.46 Max. Hz 3 9095.65 415.30 10239.46 Max Mx 2 478 38 415.29 10239.43 Max. M, 6 478.85 -10258.07 -430.67 Max. Torsion 7 1.82 -10258.10 -430.68 Min. Vert 7 9095.65 -10258.10 -430.68 Min. Hz 7 9095.65 -10258.10 -430.68 Min. H, 7 9095.65 -10258.10 -430.68 Min. M, 6 -25.33 -10258.07 -430.67 Min. Mz 2 -25.03 415.29 10239.43 Min. Torsion 1 0.00 0.00 0.00 Tower Mast Reaction Summary. Load Combination Vertical lb Dead Only 10106.27 1.2 Dead+1.6 Wind O deg - No 12127.53 Ice Shear, ib -0.00 -415.29 Shear, ib -0.00 -10239.43 Overturning Overturning Torque Moment, M Moment, M kip ft kip ft kip ft -0.37 0.06 0.00 -478.38 25.03 -0.59 0.9 Dead+1.6 Wind 0 deg - No 9095.65 -415.30 -10239.46 -475.47 24.85 -0.59 RISA JE` owe LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 10 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Load Combination Vertical Shear Shear Overturning Overturning Torque Moment, M Moment, M Ib lb lb kip ft kip ft kip ft Ice 1.2 Dead+1.6 Wind 45 deg - No 12127.53 6956.74 -6973.30 -322.18 -320.77 -1.78 Ice 0.9 Dead+1.6 Wind 45 deg - No 9095.65 6956.71 -6973.27 -320.19 -318.92 -1.78 Ice 1.2 Dead+1.6 Wind 90 deg - No 12127.53 10258.07 430 67 25.33 -478.85 -1.82 Ice 0.9 Dead+1.6 Wind 90 deg - No 9095.65 10258.10 430.68 25.28 -476.06 -1.82 Ice 1.2 Dead+1-0 Ice+1-0 Temp 16373.79 0 04 025 -0.94 0.15 1.2 Dead+1.0 Wind 0 deg+1.0 16373-77 -32.10 -1095 36 -50.36 2 12 Ice+1.0 Temp 1.2 Dead+1.0 Wind 45 deg+1.0 16373-77 752.71 -754 08 -34.63 Ice+1.0 Temp 1.2 Dead+1.0 Wind 90 deg+1.0 16373.77 1096.98 33.44 1.06 Ice+1.0 Temp Dead+Wind 0 deg - Service 10106.27 -115.69 -2852.70 Dead+Wind 45 deg - Service 10106.27 1938.14 -1942.75 Dead+Wind 90 deg - Service 10106.27 2857.90 119.98 -133.05 -89.69 6.78 -33.43 -49.32 6.99 -89.01 -132.89 -0.00 -0.05 -0.16 -0.17 -0.16 -0.50 -0.51 Solution Summary Load Comb. Sum of Applied Forces PX PY PZ Ib Ib Ib PX Ib Sum of Reactions PY PZ Ib lb % Error 1 0.00 -10106.27 0.00 0.00 10106.27 2 -415.30 -12127.53 -10239.52 41529 12127.53 3 -415.30 -9095.65 -10239.52 415.30 9095.65 4 6956.75 -12127.53 -6973.31 -6956.74 12127.53 5 6956.75 -9095.65 -6973.31 -6956.71 9095.65 6 10258.16 -12127.53 430.68 -10258.07 12127.53 7 10258.16 -9095.65 430.68 -10258.10 9095.65 8 0.00 -16373.79 0.00 -0.04 16373.79 9 -32.14 -16373.79 -1096.32 32.10 16373.77 10 753.33 -16373.79 -754.73 -752.71 16373.77 11 1097.90 -16373.79 33.45 -1096.98 16373.77 12 -115.72 -10106.27 -2853.12 115.69 10106.27 13 1938.41 -10106.27 -1943.03 -1938.14 10106.27 14 2858.31 -10106.27 120.00 -2857.90 10106.27 0.00 10239.43 10239.46 6973.30 6973.27 -430.67 -430.68 -0.25 1095.36 754.08 -33.44 2852.70 1942.75 -119.98 0.000% 0.001% 0.000% 0.000% 0.000% 0.001% 0.000% 0.002% 0.006% 0.006% 0.006% 0.004% 0.004% 0.004% Non -Linear Convergence Results Load Combination 1 2 3 4 5 6 7 8 9 Converged? Yes Yes Yes Yes Yes Yes Yes Yes Yes Number of Cycles 6 11 11 12 11 11 11 6 8 Displacement Tolerance 0.00000001 0.00000001 0.00000001 0.00000001 0.00000001 0.00000001 0.00000001 0.00000001 0.00000001 Force Tolerance 0.00000001 0.00005357 0.00004298 0.00004055 0.00012831 0.00007402 0.00005988 0.00002563 0.00012950 RISATower LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX• (425) 482-2893 Job SEA Orillia Road Page 11 of 13 Protect 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson 10 11 12 13 14 Yes Yes Yes Yes Yes 8 8 9 9 9 0.00000001 0.00000001 0.00000001 0.00000001 0.00000001 0.00012773 0.00012611 0.00012835 0.00012835 0.00014873 Maximum Tower Deflections - Service Wind Section No. Elevation fi Horz. Deflection in Gov. Load Comb. Tilt Twist LI 60 - 32 5.633 12 0.7184 0.0000 L2 35-0 2.155 12 0.5429 0.0000 Critical Deflections and Radius of Curvature - Service Wind Elevation fi Appurtenance Gov. Load Comb. Deflection Tilt in Twist Radius of Curvature ft 57.50 Valmont 13' Platform w/Rails 12 5.245 0.6972 0.0081 15479 52.00 HP2-18 12 4.404 0.6517 0.0072 9674 47.50 Valmont 13' Platform w/Rails 12 3.742 0.6169 0.0064 6191 38.00 Valmont 13' Platform w/Rails 12 2.492 0.5567 0.0049 3532 Maximum Tower Deflections - Design Wind Section No. Elevation fi Horz. Gov. Deflection Load in Comb. Tilt Twist LI 60 - 32 20.228 6 2.5782 0.0000 L2 35-0 7.751 6 1.9517 0.0000 Critical Deflections and Radius of Curvature - Design Wind Elevation fi Appurtenance Gov. Load Comb. Deflection Tilt in Twist Radius of Curvature ft 57.50 Valmont 13' Platform w/Rails 6 18.837 2.5233 0.0295 4331 52.00 11P2-18 6 15.820 2.4002 0.0261 2706 47.50 Valmont 13' Platform w/Rails 6 13.447 2.2942 0.0233 1732 38.00 Valmont 13' Platform w/Rails 6 8.961 2.0424 0.0178 987 Base Plate Design Data RISATower LDC, Inc. 14201 NE 200th St Suite #100 Woodinville, WA 98072 Phone: (425) 806-1869 FAX• (425) 482-2893 Job SEA Orillia Road Page 12 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Plate Number Anchor Bolt Actual Actual Actual Actual Controlling Ratio Thickness of Anchor Size Allowable Allowable Allowable Allowable Condition Bolts Ratio Ratio Ratio Ratio Bolt Bolt Plate Stiffener Tension Compression Stress Stress in in ib Ib ksi ksi 2.50 4 2.25 169149.41 175208.39 13.515 223654.40 371266.30 54.000 0.76 0.47 0.25 Bolt T 0.76 Compression Checks Pole Design Data Section Elevation No. ft Size L fi fi Lu KI/r A int P. OP„ ib Ib Ratio 411„ LI 60 - 32 (1) TP22.1x16.5x0.19 28.00 0.00 0.0 12.72 -8594.73 743952.00 0.012 L2 32 - 0 (2) TP28.1x21.12x0.25 35.00 0.00 0.0 22.10 -12118.00 1292790.00 0.009 Pole Bending Design Data Section Elevation No. ft Size M Ratio M , M rDM,� kip ft kip -ft 4M, kip -ft kip ft Ratio Mme, LI 60 - 32 (1) TP22.1x16.5x0.19 137.46 325.72 L2 32 - 0 (2) TP28.1x21.12x0.25 479.52 739.54 0.422 0.00 0.648 0.00 325.72 739.54 0.000 0.000 Pole Shear Design Data Section Elevation No. n Size Actual OV„ V Ib lb Ratio Actual V T 0V kip-fi 4T Ratio T kip ft 4T LI 60 - 32 (1) TP22.1x16.5x0.19 9226.40 223228.00 0.041 0.59 L2 32 - 0 (2) TP28.1x21.12x0.25 10278.40 387911.00 0.026 1.82 668.14 0.001 1517.24 0.001 Pole Interaction Design Data Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. No. P„ M x Mme, V T Stress Stress ft 4)P„ 4M (1)M„,, (I)V„ 4T Ratio Ratio Criteria R ,[ FSA Tower jl[ LDC, Inc. 14201 NE 200th St Suite #/00 Woodinville, WA 98072 Phone: (425) 806-1869 FAX: (425) 482-2893 Job SEA Orillia Road Page 13 of 13 Project 60' Monopole Date 14:20:08 05/14/10 Client Verizon Wireless Designed by randerson Section Elevation Ratio Ratio Ratio Ratio Ratio Comb. Allow. No. P M Ay V T Stress Stress ft +P„ ¢M 4)M 4)V 4)T Ratio Ratio �r Criteria LI 60 - 32 (1) 0.012 0 422 0 000 0 041 0 001 0 435 1 000 1' L2 32 - 0 (2) 0.009 0.648 0.000 0.026 0.001 0.659 1.000 4.10 -la ✓ 4.10 -la V Section Capacity Table Section No. Elevation ft Component Type Size Critical Pass Element ib lb Capacity Fail LI 60 - 32 Pole TP22.1x16 5x0 19 1 -8594 73 743952 00 43 5 Pass L2 32 - 0 Pole TP28.1x21.12x0.25 2 -12118.00 1292790.00 65.9 Pass Summary Pole (L2) 65.9 Pass Base Plate 75.6 Pass RATING = 75.6 Pass Program Version 5.3.1.0 - 10/3/2008 File:P:/2010%Telecom/10-802 Verizon - SEA Oreillia Road/Data-Engineer/SEA Onllia Rd TIA-G.en LDC, Inc. 14201 NE 200th St Suite 100 Woodinville, WA 98072 2006 IBC Pole Foundation Design Project SEA Oriilia Road sheet F1 date 5/17/10 prj. no. 10-802 Input Data: b= 5.0ft d = 12.00 ft M = 494 k -ft V = 10.60 k S = 467 lbs/ft`/ft h= 46.6 ft P = 10600 lbs Si = 1868 lbs/ft` Diameter of footing or diagonal dimension of square footing Depth of embedment (< 12' for lateral pressure calculation) Design moment from tower analysis Design shear from tower analysis Allowable lateral soil bearing (IBC table 1804.2 or geotech) Distance from ground to point of application of "P" (MN from tower analysis) Applied lateral force (V from tower analysis) Allowable lateral soil bearing at one-third depth of embedment Nonconstrained Lateral Bearing Review: A = 2.66 d = 14.27 Actual Embedment Depth = 2.34P/(S1 b) A/2(1 +(1 +(4.36h/A))v2) 17.5 ft > Required Depth (d) = 14.27 ft -> OK Date: 4-15-2010 To: Property Management SITE MODIFICATION REQUEST From: Arman Kolukcija Site: SEA Orillia Road Associated Project (i.e. 4th Carrier, Change out, WA4CDMA): LTE Phase 2 Microwave Requested Modification: Install (1) new 2' microwave antenna at 52 feet, with 80 feet of EWP90 Waveguide, To SEA Cascade. Please Note that this site will need a microwave cabinet Will this require EME mitigation?: Yes _x_ No Maximum Horizontal ERP for new configuration: Watts Will this require re -filing with the FAA/FCC group? _x_Yes No Requested In -Service Date: Current Configuration (include model, number and location of all existing antennas): Current Total Structure Ht: 60 feet (including lightning rod) Sector Quantity CL height Tip height Antenna length Tilt Azimuth Model # SEA Cascade 1 52' 53' 2' .31 75.51 HP2-1011 Description: Desired Configuration (include model, number and location of all proposed antennas) Proposed Total Structure Ht: 60 feet (including lightning rod) Sector Quantity CL height iP h ght Antenna length Tilt Azimuth Model # SEA Cascade 1 52' 53' 2' .31 75.51 HP2-1011 Description: Install (1) new 2' microwave antenna at 52 feet, with 80 feet of EWP90 Waveguide, To SEA Cascade. Please Note that this site will need a microwave cabinet SMR.doc 05/14/2010 J ID:3a rmumcira: Tnulci unrur cue-acts-uoia 1-ur.u4icu r-313 /(Pole (tm) - Monopole Design Program Windows Version 1.28.0100 Wed Nov 3, 1999 - 9:22:36 am (c) 1993 to 1998 PAUL J. FORD AND COMPANY, Columbus, Ohio Job No • Description : Design • Ownor : Statue • 29299-682 Design No: Summit Job #5558 Engineer : RET 60 -Ft Monopole - S 270 Row Lake Transfer Station: Tukwila, WA 90 mph/78 mph + 1/2' Radial Ice U. S. West Client: Summit manufacturing, LLC Engineering Final Design Revision: Rev. Date : SUMMARY OF ANALYSIS RESULTS Polo Height Top Diameter Bottom Diameter Pole Shape Splits., Joint Type...: Shaft Taper Shaft Steel Weight..: 60.00 ft 16.500 in 28.130 in 18 -Sided Polygon Taper shaft - Slip Joints Splice 0.200083 (in/ft) 3.376 kips POLE SHAFT PROPERTIES: shaft Section )l'am'er Section Length (ft) Wall Thickness (t] (in) steel Timid (FO (kai) Top Diameter Mt] (in) Bottom Diameter [Db] (in) Slip Joint Overlap (in) 2. 27.750 35.000 0.18750 65 0.25000 65 16.500 21.127 22.052 28.130 33.00 POLE SHAFT SECTION MAXIMUM FORCES AND MOMENTS: Shaft Section Number' Wind Load No. Wind Speed (mph) Radial Sect. Ice Elev. (in) (ft) At Dasa of auction Axial Horiz. Load Shear (kips) (kips) Bending Moment (ft -kips) Max. Ratio Actual/ Allowable (Vtot/Fb] 90.0 0.00 35.00 5.074 8.964 90.0 0.00 0.00 7.321 10.560 150.062 494.356 0.5329 0.7578 » MAXIMUM BASK REACTIONS : 7.321 10.560 494.356 « POLE DEFLECTION AND ROTATION AT TOP AND AT =REST MICROWAVE DISE ELEVATION: Wind Load No. Wind Radial Speed Ice (mph) (in) Location Elev (ft) Max. Allowable Deflection Rotation Rotation Limit (in) (deg) (deg) 1- 2. .2. 3 - 90.0 77.9 50.0 0.00 0.50 0.00 Top Top Top 60.00 60.00 60.00 21.448 17.746 6.617 2.740 2.272 0.846 DEC 13 '99 16:50 206 328 0815 PAGE..04 39 15:59 FROM:THE WALTER GROUP AT MANUFACTURING, LLC SKIWANIS BOULEVARD, WESTHAZLETON, PA 182111 MHONO:1E1681847 6527 EMAIL' SUMMITCA@EPOT.NET FAX: .maw 060'6885 WWW.SIJMMITMFGLLC.CDM c,POLE & FOUNDATION POLE SHAFT & BASE PL. DOUBLE HEAVY HEX NUT W/ WASHER 3" GAP (NO GROUT) -ANCHOR - BOLTS . HEAVY HEX cra LEVEUNG NUT a - W/ WASHER 206-328-0815 T-033 P.03/20 F-519 alPAUL J. FORD AND COMPANY STRUCTURAL ENGINEERS 250 East Broad Street, Suite 500, Columbus, Ohio 43215 (614) 2216679 Fax: (614) 221-0166 www.PJFweb.com FIN GRADE z REM 15 TIES 18" C/C CAISSON DEC 13 '99 16:50 2'-0• MIN LAP (16)-j9 VERT RE NF FULL HEIGHT i age o o- •o. RKT Design No. Chk•d By Del. KJS Rev. No. Pale 60 -FT MONOPOLE Site SEA170 BOW LAKE TRANSFER STA'tION: TUKWILA, WA Owner U. S. WEST ' "' " Ref. No. Design 90 MPH/78 MPH + 1/2- RADIAL•1Cc • ACCORDING TO TIA EIA -222-F 1996 292.9-::2 suuurr Joei nt Rev. Dote THERE ARE TWO NOTCHES ON THE ANCHOR BOLT TEUPLATES LOCATED 180' APART. THE CONTRACTOR SHALL POSITION THE ANCHOR BOLTS AND TEMPLATES IN THE FOUNDATION PER THE SUMMIT MANUFACTURING ANCHOR BOLT TEMPLATE DRAWING. NOTES: 1. ALL CONCRETE SHALL. HAVE A MIUUIMI COMPRESSIVE STRENGTH OF 3000 PSI Al 28 Wilt. CONCRETE SHALL BE NR ENTRAINS° (661.576). CONCRETE SHALT. HAVE + MAXIMUM WA1'ER/Ct11FM RAM OF 0.4. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH INE 8Uq.O O GIDE REOUAREMENTS FOR REVIFORCED CONCRETE". Alp 318, LATEST ONION. FOUNDATION INSTALLATION SHALL 9E DM ACCORDANCE EDI AC1336. STAXDARD OK SPECIFICATIONS SCATIONS FOR THE CONSTRUCTION DRILLED PIERS•. LATE 2. REINFORCING STEEL MALL CONFORM TO THE REOIAREMENTS OF PSTN 4-613 WADE Co) EXCEPT THAT CASSON TIES VAT 9E AWN A-615 (GRADE 40). ALL REINFORCING DETAILS SHAIL CONFORM TO 'MANUAL OF STANDARD PRACTICE FOR OETAIUNG REINFORCED CONCRETE STRUCTURES: ACI 31S. LATEST EOITIWO, UNLESS DETAILED OTHERWISE ON THIS DRAWING. 3. SEE PAGE 1 FOR ANCHOR BOLT MARTIN. SIZE, LENGTH, AND BOLT CIRCLE 4. TOTAL CONCRETE s 12.7 CUBIC VARDS. 5. FOUNDATION OE ON IS MED UPON CE01ICH LAICAL EXPLORATION REPORT PREPARED BYI ZIPPER ZEMAN ASSOCIATES. INC REPORT NO.: J-477 NEO: 09-15-1999 6` CONTRACTOR SMALL READ INC GEOID:MOM REPORT AND CONSULT THE GEOTECHNICAL ENGINEER AS NECESSARY PRIOR TO CONSTRUCTION, 7. GEOTECHNICAL REPORT AIDICATES GROW0)WAIER WAS ENCOUNTERED AT 13'-6' BELOW GRADE, & THE FOUNDATION ARCS DESIGNED USING uouEN : S75 rT-KIPS SHEAR 12 MPS AXIAL: • 8 RPS 9. GEOTECHNICAL REPORT PREPARED TO CASE INC HOLE IF NE NOTE OEOTECHN1CAL REPORt' INDICATES THAT UNDERGROUND UTBJRES ARE LOCATED 01 TFlE V1COtttY. OF THE PROPOSED MONOPOLE LOCATION. DRILLED PIER) FOUNDATION 206 328 0815 PAGE.03 . r c 4 15:50 FROM:THE WALTER GROUP .4111 MANUFAU 1 UKINGI LLU .'K$wANIS BOULEVARD. WEST HAZLITON, PA 15201 :HONE: 1888) 547.6537 E-MAIL: SUMMITCA@EPIX.NET • FAX: 1858) 4646585 WWW.SUMMITMFGLLC.COM 18.500' At710SS FATS {EST 16WT .0 3• MPS) (Fr�) T/TN SPUC.E LENGTH WN a 29.70' DESIGN = 33.00' MAX IS 36.30' 4114; •cst T� (Fr s)% 206-328-0815 7-033 P.02/20 alri-ILJL. J. 1 V I\U A-11 r LJ STRUCTURAL EN 250 East Broad Street, Suite 500, Col (614) 2214679 Fax: (614) 2210166 F-519 L.VIVIrhIN T. GINEERS umbus, Ohio 43215 www.PJFweb.com a O r Tqee �2 ogA Job No. 2999-2-7a2 Design No. SUMMIT JOB OMB Date 11-03-1999 8y RKT Chk'd BY KJS Rev. No. Rev. Dote 'ole 60- 7, • • ' • >f i e S 70 BO TRAN ' - ' A • N: KWILA. WA "Owner. 5. WES Ref No. Design 90 MPH/75 MPH + l/'2- ACCORDING TO TIA/EIA-222-F RADIAL. ICE 1996 LOAD C 5 CASE 1 CASE 2 CASE 3 90 MPH wn1'F1 NO ICE 78 MPH WITH 1/2' RADIAL ICE 50 MPH WITH NO ICE DESIGN W NI D REDUCED WINO WITH ICE OPERATIONAL. WINO PO S • EC c TIOFIS ole A ape yin : - ' • ' • Yes 1 No. Ta • er. 0.200083 IN - Qf Steak ASTM • • ►T • Base PL Sleek ASTM A572 ' 13 50 50 K1 Ancor:• 21 40x8-. •N _118J ASTit1 A615 GRADE 75 ANTENNA LIST 5o MPH - No. Elev. " Descript;on - TOP 5/8' IMMIX ROO 21.4 2,740 6.6 0.846 1-2 57.50 57.50 2 ELLS R1433 -20 -ELY- 3 12 -FT Y ARMS 3-5 56.00 3 US WEST1tEI10TE UNIT + ', 1p P. 6-8 53.00 3 EMS RR33-20-X)L.P y .c, 40 ‘VAS - 53.00 TRI -ARM SUPPORT ASSEMBLY . 0-11 62.00 US WEST REMOTE UNIT' ' r.. �- .: 12-19 47.50 47.50 8 =ON 7131.20 SECTORh 1331 12 -FT T ARMS .. SHAFT MPH WIND 5o MPH vivo Elevation Lateral Deflection (Inches) Rotation (sway) (degrees) Lateral Deflection (Inches) Rotation (sway) (degrees) Toe 21.4 2,740 6.6 0.846 22.052 25.130 NOTE DIMENSIONS SHOWN DO NOT INCLUDE GALVANIZING TOLERANCES SHAFT SECTION DATA Diameter Across (inches) Flats o Bottom Shaft Scalae Section Length (feet) . Plate Thickness on.) Lop Slice (in.) 0 Tap 1 2 27.75 35.00 , 0.1875 0.2500 33.00 16.500 21.127 22.052 25.130 NOTE DIMENSIONS SHOWN DO NOT INCLUDE GALVANIZING TOLERANCES FOR IN FOUNDATION REACTIONS USE It 2.226 0 13 MOOR BOLTS 011 34.000' B.C. .WITH IaM. Y -D" OVERT INTO PIER (VI/NUTS & TQIPIATE PATE 0 BOY.) 28.130' ACROSS FIATS DEC 13 '99 16:49 206 328 0815 MOMZNT = 575 ft -kips SHEAR = 12 kips AXIAL = 8 kips PAGE.82 4. E 1/e1Ymp wireless GENERAL LOCATION MAP NOT TO SCALE DRIVING DIRECTIONS FROM VERIZON WIRELESS OFFICE: • HEAD SOUTH ON 161ST AVE SE TOWARD SE EASTGATE WAY • TAKE THE RAMP TO I-90 W • FOLLOW SIGNS FOR 1-90 W/SEATTLE AND MERGE ONTO 1-90 W • TAKE EXIT 10 TO MERGE ONTO 1-405 S TOWARD RENTON • TAKE THE EXIT ONTO 1-5 S TOWARD RENTON • TAKE THE EXIT 152 FOR ORILLIA RD • TURN LEFT AT ORILLIA RD S • DESTINATION WILL BE ON THE LEFT NEXT TO THE TRANSFER STATION APPROVAL / SIGN OFF APPROVED BY DATE SIGNATURE SITE ACQUISITION ZONING RF CONSTRUCTION MANAGER PROJECT MANAGER REVIEWERS SHALL CLEARLY PLACE INITIALS ADJACENT TO EACH REDLINE NOTE AS DRAWINGS ARE BEING REVIEWED -PG RE*LCOM I SEA ORILLIA RD S (aka SEA BOISCO) 18700 ORILLIA ,RD S TUKWILA, WA 98188 VICINITY MAP NOT TO SCALE LEGAL DESCRIPTION COMMENCING AT THE WEST QUARTER OF SAID SECTION 35, THENCE SOUTH 87°56'21" EAST ALONG THE EAST -WEST CENTERLINE OF SAID SECTION 35 A DISTANCE OF 960.00 FEET; THENCE LEAVING SAID SECTION CENTERLINE SOUTH 53°24'38" WEST, 727.57 FEET; THENCE SOUTH 38°42'29" EAST, SAID COURSE HEREAFTER BEING REFERRED TO AS COURSE "A", 1,144.92 FEET TO A POINT ON THE NORTH LINE OF THE SOUTHWEST QUARTER OF THE SOUTH WEST QUARTER OF SAID SECTION 35, 100 FEET WEST FROM THE NORTHEAST CORNER THEREOF AND THE TRUE POINT OF BEGINNING; THENCE SOUTH 04°04'10" WEST PARALLEL TO THE EAST LINE THEREOF, 490 FEET; THENCE NORTH 87°57'23" WEST PARALLEL TO THE NORTH LINE THEREOF, 920.96 FEET MORE OF LESS TO THE EASTERLY MARGIN OF WASHINGTON STATE PRIMARY HIGHWAY NO.5; ACCORDING TO THE SURVEY LINE OF SR 5 SOUTH 188TH ST. INTERCHANGE; THENCE NORTHERLY ALONG SAID EASTERLY MARGIN OF WASHINGTON STATE PRIMARY HIGHWAY NO.5 TO A POINT INTERSECTING WITH THE SOUTH RIGHT-OF-WAY MARGIN OF ORILLIA ROAD EXT. N.; THENCE SOUTH 65°13'16" EAST, 502.58 FEET TO A POINT ON A LING 700 FEET EAST OF AND PARALLEL WITH SURVEY LIN Lw OF SR 5 SOUTH 188TH ST. INTERCHANGE; THENCE SOUTH 09°34'47" WEST PARALLEL WITH WASHINGTON STATE PRIMARY HIGHWAY NO.5 LINE Lw A DISTANCE OF 292.56 FEET MORE OR LESS TO A POINT INTERSECTING WITH COURSE "A"; THENCE SOUTH 38°42'29" EAST ALONG COURSE "A", 486.85 FEET MORE OR LESS TO THE TRUE POINT OF BEGINNING. CONTAINING 873,082 SQUARE FEET OR 20.04 ACRES, MORE OR LESS. PROJECT CONTACT LIST APPLICANT: VERIZON WIRELESS 3350 161ST AVE SE BELLEVUE, WA 98008 PROJECT ENGINEER: LDC, INC. 14201 NE 200TH ST, SUITE 100 WOODINVILLE, WA 98072 CONTACT BERT WHITE PHONE (425) 806-1869 FAX: (425) 482-2893 EMAIL, bwhite@Idccorp.com STRUCTURAL ENGINEER: LDC, INC. 14201 NE 200TH ST, SUITE 100 WOODINVILLE, WA98072 CONTACT MARK VILLWOCI P.E. PHONE (425) 806-1869 FAX: (425) 482-2893 EMAIL: mvdlwock@Idccorp.com PROJECT SURVEYOR: LDC, INC. 14201 NE 200TH ST, SUITE 100 WOODINVILLE, WA 98072 CONTACT DARREN RIDDLE, PLS PHONE: (425) 806-1869 FAX: (425) 482-2893 EMAIL: driddle@Idccorp.com PROPERTY OWNER: KING COUNTY CONTACT: TBD PHONE: TBD PROJECT CONSULTANT: REALCOM ASSOCIATES LLC. 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007 CONTACT: OLIVIA BAZYLEWICZ PHONE (425) 274.4444 EX. 118 FAX (425) 274-4449 EMAIL obaz@realcomassoc.com PROJECT MANAGER: REALCOM ASSOCIATES LLC. 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA98007 CONTACT JULEI HINTY PHONE (425) 274-4444 EX. 128 FAX (425) 274-4449 EMAIL: ihinty@realcomassoc.com PERMITTING: REALCOM ASSOCIATES LLC. 14432 SE EASTGATE WAY, SUITE 260 BELLEVUE, WA 98007 CONTACT SARAH TELSCHOW PHONE (425) 274-4444 EX. 114 FAX (425) 274-4449 EMAIL stelschow@realcomassoc.com PROJECT INFORMATION CODE INFORMATION: ZONING CLASSIFICATION: BUILDING CODE: CONSTRUCTION TYPE: OCCUPANCY: JURISDICTION: PROPOSED BUILDING USE: TVS - TUKWILA VALLEY SOUTH IBC 2006 TELECOMMUNICATIONS GROUP "U" CITY OF TUKWILA UNMANNED TELECOM SITE LOCATION (NAD83): LATITUDE 47°26'00.10' N LONGITUDE: 122°16'10.50' W TOP OF STRUCTURE: 337.0' AMSL BASE OF STRUCTURE: 277.0' AMSL (47.433361° N) (122.269583° W) 60'-O AGL 0'-0" AGL PROJECT LEASE AREA: PARCEL NUMBER: 300 SF 3523049037 NEW IMPERVIOUS AREA: AREA OF PARCEL: 0 SF 20.04 AC GENERAL INFORMATION: 1. PARKING REQUIREMENTS ARE UNCHANGED 2. TRAFFIC IS UNAFFECTED. 3. SIGNAGE IS PROPOSED. PROJECT DESCRIPTION: VERIZON WIRELESS PROPOSES TO INSTALL A 2'0 MICROWAVE ON AN EXISTING 60' MONOPOLE AND A MICROWAVE SUPPORT CABINET ON AN EXISTING EQUIPMENT PLATFORM, WHICH IS LOCATED WITHIN AN EXISTING WIRELESS COMPOUND. DRAWING INDEX DWG NO. ,, DESCRIPTION T-1 TITLE SHEET G-1GENERAL NOTES A-1 I OVERALL SITE PLAN A-1.1 ' EXISTING SITE PLAN A-1.2 PROPOSED SITE PLAN A-2 , EXISTING ELEVATION A-2.1 I PROPOSED ELEVATION A-3 I ANTENNA DETAILS A-3.1 rCABINET DETAILS UTILITY COMPANIES POWER: ON SITE: PSE (888) 225-5773 SCALE DISCLAIMER TELEPHONE: ON SITE: QWEST (800) 475-7526 DO NOT SCALE DRAWINGS. CONTRACTOR MUST VERIFY ALL DIMENSIONS AND ADVISE CONSULTANTS OF ANY ERRORS AND OMISSIONS. ALL PREVIOUS ISSUES OF THIS DRAWINGS ARE SUPERSEDED BY THE LATEST REVISION. PROPRIETARY INFORMATION THE INFORMATION CONTAINED IN THIS SET OF CONSTRUCTION DOCUMENTS IS PROPRIETARY BY NATURE. ANY USE OR DISCLOSURE OTHER THAN THAT WHICH RELATES TO VERIZON WIRELESS SERVICES IS STRICTLY PROHIBITED. PREVIOUS PERMIT APPROVALS MI99-022 MI99-0203 007-235 L09-058 Cd 2 Business Days Before You Db 1-800-424-5555 =es Underground Loeatlon Center (13. dt)D,ORWA) 0 V W LDC Ahitectural E ngineering Structural 111E CMI. ENCINEFIUNC CROUP Survey 14201 NE 200th St.. 0100 P5 425808.1889 Wood4NWe. WA 98072 Fc. 425.482.2893 www.LOCcorp 80m DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV GATE DESCRIPTION BY 5-11410 PRELIMINARY CONSTRUCTION BEW 2 &15-10 REVISE0 COS BEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA 98188 SHEET TITLE TITLE SHEET SHEET NUMBER T-1 GENERAL NOTES: 1 THE PROPOSED INSTALLATION WLL BE UNMANNED AND DOES NOT REQUIRE POTABLE WATER OR SEWER SERVICE. 2. THE PROPOSED INSTALLATION IS UNMANNED AND IS NOT FOR HUMAN HABITATION (NO HANDICAP ACCESS IS REQUIRED) 3. OCCUPANCY IS UMITED TO PERIODIC MAINTENANCE AND INSPECTION, APPROXIMATELY 2 TIMES PER MONTH, BY VERIZON WIRELESS TECHNICIANS. 4 NO NOISE, SMOKE, DUST OR ODOR WLL RESULT FROM THIS PROPOSAL. 5 OUTDOOR STORAGE AND SCUD WASTE CONTAINERS ARE NOT PROPOSED. 6 ALL REFERENCES TO SPECIFIC STANDARDS FOR THIS PROPOSAL ARE UNDERSTOOD TO BE THE LATEST VERSION. 7 THE TENDERED MUST UNDERGO A SITE VISIT TO CAREFULLY EXAMINE AND UNDERSTAND THE SCOPE OF THE WORK REQUIRED BEFORE BID SUBMISSION. NO COMPENSATION IN ANY FORM WILL BE PAID FOR EXPENSES RESULTING FROM FAILURE TO DO SO. 8 IF THE SPECIFIED EQUIPMENT CAN NOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, THE CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL BY THE CONSTRUCTION MANAGER. 9 CONTRACTOR IS RESPONSIBLE FOR FIELD MEASUREMENTS TO CONFIRM LENGTHS OF CABLE TRAYS, ELECTRICAL LINES, AND ANTENNA CABLES. 10. ROUTING OF ALL CONDUITS, CABLES, CABLE TRAYS, ETC. IS INDICATED AS PROPOSED LOCATIONS ONLY. CONFIRM THE EXACT ROUTING WITH THE ON-SITE CONSTRUCTION MANAGER PRIOR TO THE START OF WORK. 11 ALL DAMAGE OR OPENING UP OF THE EXISTING STRUCTURE MUST BE MADE GOOD TO THE PRECONSTRUCHON CONDITION OR BETTER. 12 INSPECTION OF COMPLETED WORK IS REQUIRED BEFORE COVERING UP. PROVIDE A MINIMUM OF 72 HOURS NOTICE TO CONSULTANT. 13 REMOVE AND CLEAN UP ANY DEBRIS OR MATERIAL FROM THE SITE THROUGHOUT THE DURATION OF THE CONTRACT ON A DAILY BASIS AND UPON COMPLETION OF THE WORK AS DIRECTED BY THE CONSTRUCTION MANAGER. 14 OBTAIN AND PAY FOR ALL ELECTRICAL PERMITS AND INSPECTIONS REQUIRED FOR COMPLETION OF WORK AND ACCEPTANCE. PROVIDED CERTIFICATES TO THE CONSTRUCTION MANAGER VERIFYING THAT THE WORK CONFORMS TO THE REQUIREMENTS OF ALL CODES AND AUTHORITIES HAVING JURISDICTION. 15 PROVIDE VERIZON WIRELESS WITH A WRITTEN WARRANTY, EFFECTIVE FOR ONE YEAR AFTER DATE OF ACCEPTANCE. FOR THE COMPLETE INSTALLATION REPAIR OR REPLACE ANY DEFECTS ARISING DURING THIS PERIOD AT NO EXTRA COST TO VERIZON WRELESS. 16 NO DEVIATIONS FROM DESIGN SHOWN ON THESE DRAWINGS IS ALLOWED WITHOUT WRITTEN APPROVAL FROM THE CONSULTANT. FAILURE TO OBSERVE THIS RULE MAY RESULT IN CONTRACTOR CORRECTING THE INSTALLATION AT THEIR EXPENSE. ABBREVIATIONS: AFF AFG AFS ALUM AB ARCH BTS BLDG BM BOT B 0. BOC BOS CJ CLG CLR CMU COL CONC CONST CONT CTR DIA /0 DTL (E) EA EJ ELEC EL EQ EW EXP EXT FD FIN FIN FLR FLR FTG GA GALV GYP GB HM HOR HR HT HVAC INSUL INT ABOVE FINISHED FLOOR ABOVE FINISHED GRADE ABOVE FINISHED SLAB ALUMINUM ANCHOR BOLT ANGLE ARCHITECTURAL BASE TRANSMISSION SYSTEM BUILDING BEAM BOTTOM BOTTOM OF BOTTOM OF CONCRETE BOTTOM OF STEEL CONTROL JOINT CENTER UNE CEIUNG CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONSTRUCTION CONTINUOUS CENTER DIAMETER DETAIL EXISTING EACH EXPANSION JOINT ELECTRIC/ELECTRICAL ELEVATION EQUAL EACH WAY EXPANSION EXTERIOR FLOOR DRAIN FINISH FINISH FLOOR FLOOR FOOTING GAUGE GALVANIZED GYPSUM GYPSUM BOARD HOLLOW METAL HORIZONTAL HOUR HEIGHT HEATING VENTILATION AIR CONDITIONING INSULATION INTERIOR Ji LAM LF MANUF MAX MECH MH MM MIN MISC MPH MTL NIC NOM NTS OC OD 01-1 OPNG OPP PCS PR PSI PSF PT RAD RD REINF REOD RM RNV SCHED SECT SF SIM SO FT SS STD STL STRUC TEMP THK T.O. TOS TOC TYP UNO VERT W/ WVMA JOINT LAMINATED LINEAL FOOT MANUFACTURER MAXIMUM MECHANICAL MANHOLE MILUMETER MINIMUM MISCELLANEOUS MILES PER HOUR METAL NOT IN CONTRACT NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER OVERHEAD OPENING OPPOSITE PERSONAL COMMUNICATION SYSTEM PLATE PAIR POUNDS PER SQUARE INCH POUNDS PER SQUARE FOOT PRESSURE TREATED RADIUS ROOF DRAIN REINFORCED/REINFORCING REQUIRED ROOM RIGHT OF WAY SCHEDULE SECTION SQUARE FOOT SIMILAR SQUARE FOOT STAINLESS STEEL STANDARD STEEL STRUCTURAL TEMPORARY THICK TOP OF TOP OF STEEL TOP OF CONCRETE TYPICAL UNLESS NOTED OTHERWISE VERTICAL WITH WELDED WIRE MESH CONCRETE NOTES: 1 ALL CONCRETE CONSTRUCTION SHALL BE IN ACCORDANCE WITH ACI -318. 2. CONCRETE SHALL BE MIXED, PROPORTIONED, CONVEYED AND PLACED IN ACCORDANCE WITH IBC 2006 SECTION 1905 AND ACI 301. STRENGTHS AT 28 DAYS AND MIX CRITERIA SHALL BE AS FOLLOWS TYPE OF CONSTRUCTION 28 DAY STRENGTHS (fc) A. SLABS ON GRADE TOPPING SLABS CONCRETE PIERS 3000 PSI B. ALL STRUCTURAL CONCRETE 3000 PSI C. CONCRETE FOUNDATIONS 3000 PSI CEMENT SHALL BE ASTM C150, PORTLAND CEMENT TYPE II UNLESS NOTED OTHERW SE. 3. THE CONSTRUCTION MANAGER SHALL SUPERVISE AND BE RESPONSIBLE FOR THE METHODS AND PROCEDURES OF CONCRETE PLACEMENT. 4. ALL CONCRETE VNTH SURFACES EXPOSED TO STANDING WATER SHALL BE AIR -ENTRAINED WITH AN AIR -ENTRAINED AGENT CONFORMING TO ASTM C260, C494, C618, C989 AND C1017. TOTAL AIR CONTENT SHALL BE IN ACCORDANCE WTH TABLES 1904 OF THE IBC 2008. 5. REINFORCING STEEL SHALL CONFORM TO ASTM A615 (INCLUDING SUPPLEMENT S1), GRADE 60, fy=60,000 PSI. EXCEPTIONS: ANY BARS SPECIFICALLY SO NOTED ON THE DRAWINGS SHALL BE GRADE 40, fy-40,000 PSI. GRADE 60 REINFORCING BARS INDICATED ON DRAWINGS TO BE WELDED SHALL CONFORM TO ASTM A706. REINFORCING COMPLYING WITH ASTM A615(S1) MAY BE WELDED ONLY IF MATERIAL PROPERTY REPORTS INDICATING CONFORMANCE WITH WELDING PROCEDURES SPECIFIED IN AWS D14 ARE SUBMITTED. 6. REINFORCING STEEL SHALL BE DETAILED (INCLUDING HOOKS AND BENDS) IN ACCORDANCE WTH ACI 315 AND 318. LAPP ALL CONTINUOUS REINFORCEMENT AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF Z-0". PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP CORNER BARS AT LEAST 30 BAR DIAMETERS OR A MINIMUM OF 2'-0". LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 8" AT SIDES AND ENDS 7. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185. 8. SPIRAL REINFORCEMENT SHALL BE PLAIN WIRE CONFORMING TO ASTM A615, GRADE 60, fy�0,000 PSI 9. NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS SPECIFICALLY SO DETAILED OR APPROVED BY THE ENGINEER OF RECORD. 10. CONCRETE PROTECTION (COVER) FOR REINFORCING STEEL SHALL BE AS FOLLOWS: A. FOOTINGS AND OTHER UNFORMED 3" SURFACES, EARTH FACE B. FORMED SURFACES EXPOSED (#6 BARS OR LARGER) 2" TO EARTH OR WEATHER (#5 BARS OR SMALLER) 1 VY C. SLABS AND WALLS (INTERIOR FACE) 3/4" 11. BARS SHALL BE SUPPORTED ON CHAIRS OR DOBIE BRICKS 12. ANCHORS BOLTS TO CONFORM TO ASTM A307 13. NON -SHRINK GROUT SHALL BE FURNISHED BY AN APPROVED MANUFACTURER AND SHALL BE MIXED AND PLACED IN STRICT ACCORDANCE WTH THE MANUFACTURE'S PUBUSHED RECOMMENDATIONS. GROUT STRENGTH SHALL BE AT LEAST EQUAL TO THE MATERIAL ON - WHICH IT IS PLACED (3,000 PSI MINIMUM) LEGEND AND SYMBOLS: CHAIN LINK FENCE CEDAR FENCE ❑ POWER UNDERGROUND POWER TELCO UNDERGROUND TELCO OVERHEAD POWER BOUNDARY CENTERLINE REVISION BUG ELEVATION DETAIL NUMBER SHEET NUMBER SECTION BUG ucP UGT 011 ob,PROPOSED ELEVATION 0'-0" AGL AT- -1A ST N TES: -la 1. SHOP DRAWINGS FOR STRUCTURAL STEEL SHALL BE SUBMITTED TO THE CONSULTANT FOR REVIEW PRIOR TO FABRICATION. 2. STRUCTURAL STEEL DESIGN, FABRICATION, PAINTING AND ERECTION (INCLUDING FIELD WELDING, HIGH STRENGTH FIELD BOLTING, EXPANSION BOLTS, AND THREADED EXPANSION ANCHORS) SHALL BE BASED ON THE AISI 'SPECIFICATIONS FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS' LATEST EDITION. SUPERVISION SHALL BE IN ACCORDANCE WITH IBC 2008 CHAPTER 17, BY A QUAUFIED TESTING AGENCY DESIGNED BY THE CONSULTANT. THE CONSULTANT SHALL BE FURNISHED WITH A COPY OF ALL INSPECTION REPORTS AND TEST RESULTS. 3. STRUCTURAL STEEL SHALL CONFORM TO THE FOLLOW NG REQUIREMENTS: TYPE OF MEMBER A. WIDE FLANGES B PLATES, SHAPES, ANGLES AND RODS C SPECIAL SHAPES AND PLATES D PIPES E STRUCTURAL TUBING F. ANCHOR BOLTS G. CONNECTION BOLTS ASTM A992, y=50 KSI ASTM A36, fy=35 KSI ASTM A572, fy=42 KSI ASTM A53, fy=35 KSI ASTM A500, fy=46 KSI ASTM A307 ASTM A325 4. ALL MATERIAL TO BE HOT DIPPED GALVANIZED AFTER FABRICATION PER ASTM A123 /A123M-0O. 5. ALL WELDING SHALL BE IN CONFORMANCE WITH AI SC AND VERIZON WIRELESS STANDARDS AND SHALL BE PERFORMED BY WABO CERTIFIED WELDERS USING E70XX ELECTRODES. ONLY PRE QUAUFIED WELDS (AS DEFINED BY VERIZON WRELESS) SHALL BE USED. WELDING OF GRADE 60 REINFORCING BARS OF REQUIRED) SHALL BE PERFORMED USING LOW HYDROGEN ELECTRODES. WELDING OF GRADE 40 REINFORCING BARS (IF REQUIRED) SHALL BE PERFORMED USING E7OXX ELECTRODES. WELDING WITHIN 4' OF COLD BENDS IN REINFORCING STEEL IS NOT PERMITTED. SEE REINFORCING NOTE FOR MATERIAL REQUIREMENTS OF WELDED BARS. 6. COLD -FORMED STEEL FRAMING MEMBERS SHALL BE OF THE SHAPE, SIZE, AND GAGE SHOWN ON THE PLANS. PROVIDED MINIMUM SECTION PROPERTIES INDICATED. ALL COLD -FORMED STEEL FRAMING SHALL CONFORM TO THE AISI "SPECIFICATION FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS.' 7. BOLTED CONNECTIONS SHALL USE BEARING TYPE ASTM A325 BOLTS (3/4"0) AND SHALL HAVE A MINIMUM OF TWO BOLTS UNLESS NOTED OTHERWISE ALL ASSEMBUES ARE TO BE TIGHTENED IN ACCORDANCE WITH 'SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR A490". JUNE 30, 2004. FOR BEARING -TYPE CONNECTIONS AS A MINIMUM. THE BOLTS SHALL BE TIGHTENED TO A "SNUG TIGHT CONDITION. A'SNUG TIGHT CONDITION IS DEFINED AS THE TIGHTNESS THAT EXISTS WHEN ALL PLIES IN A JOINT ARE IN FIRM CONTACT. THIS MAY BE ATTAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF A MAN USING AN ORDINARY SPUD WRENCH. 8. NON-STRUCTURAL CONNECTIONS FOR STEEL GRATING MAY USE 5/8"0 ASTM A307 BOLTS UNLESS NOTED OTHERWISE. 9. ALL WELDS TO BE 1/4" FILLET UNLESS NOTED OTHERWISE 10. TOUCH UP ALL FIELD DRIWNG AND WELDING WITH 2 COATS OF GALVACON (LNC RICH PAINT) OR APPROVED EQUAL SPECIAL INSPECTIONS: SPECIAL INSPECTIONS IN ACCORDANCE WITH IBC 2008 SECTION 1704 SOILS/GEOTECHNICAL: 0 SHORING INSTALLATION AND MONITORING 0 OBSERVE AND MONITOR EXCAVATION 0 VERIFY SOIL BEARING psf BEARING 0 SUBSURFACE DRAINAGE PLACEMENT D VERIFY FILL MATERIAL AND COMPACTION D VERIFY CONDITIONS AS ANTICIPATED 0 PILE PLACEMENT (AUGER CAST/DRIVEN PILE) 0 OTHER REINFORCED CONCRETE: 0 REINFORCING STEEL AND CONCRETE PLACEMENT 0 PRESTRESSED/PRECAST CONCRETE FABRICATION AND ERECTION 0 BATCH PLANT INSPECTION 0 SHOT CRETE 0 GROUTING 0 OTHER STRUCTURAL STEEL: 0 FABRICATION AND SHOP WELDS 0 ERECTION AND FIELD WELDS AND BOLTING 0 OTHER STRUCTURAL ALUMINUM: 0 FABRICATION AND SHOP WELDS 0 ERECTION AND FIELD WELDS AND BOLTING 0 OTHER STRUCTURAL MASONRY: ❑ CONTINUOUS ❑ PERIODIC D OTHER' ANCHORING TO CONCRETE: 0 BOLTS INSTALLED IN CONCRETE 0 POST -INSTALLATION ADHESIVE ANCHORS 0 POST -INSTALLATION MECHANICAL ANCHORS 0 V W Ve1`111 wireless LDC THE GN9 ENGINEERING GROUP Architectural Engineering Structural Survey 14201 NE 200111 0t_ 1100 PR 425.508.1889 W004458., WA 98072 FR. 425.482.2893 www.LOCcorpoom DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 5-1910 PRELIMINARY CONSTRUCTION BEW 2 615-10 REVISED CDS BEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA 98188 SHEET TITLE GENERAL NOTES SHEET NUMBER G-1 E P.\2010\_Telecom \10-802 Verizon - SEA Orillio Rood\Dro ings\Construction\10802CD-Al-D.dwg EXISTING PLATFORM MOUNTED EQUIPMENT EXISTING TOWER 9'-2" TOWER SETBACK N 1017'46' E 15804' EXISTING PLATFORM MOUNTED EQUIPMENT 1 I N •��c�ry4 !Y if 9 9 h 2 ' G5 Z 131'-10" TOWER SETBACK PROPERTY UNE L=181.69 R=3085.00 =3'22'28" 888'-0" TOWER SETBACK NE N 875"TY W 11920.96' OVERALL SITE PLAN 22'x34" SCALE: 1"=100' I 11'x17" SCALE: 1" = 200 1 LDC THE CIVIL ENGINEERING GROUP Architectural Engineering Stnoctural Survey 14201 NE 200th St.. 9100 Ph. 425.808.1869 Woodinville, WA 98072 PR. 425.482.2893 www.LDCcorp.com DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 5-19.10 PRELIMINARY CONSTRUCTION BEW 2 81510 REVISED COS BEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA 98188 SHEET TITLE OVERALL SITE PLAN SHEET NUMBER A-1 E Drawing: P:\2010\_Telecom\10-802 Verizon — SEA Orillia Road\ Drawings \ Construction \10802CD—At-1 EXISTING CHAIN LINK FENCE WITH PRIVACY SLATS k EXISTING VERIZON WIRELESS RAISED PLATFORM WITH EQUIPMENT CABINETS . EXISTING ELECTRICAL CABINET EXISTING VERIZON IWIRELESS SERVICE METER • EXISTING TELCO PEDESTAL 1 11/ EXiS �'AD/eQU PME/VTCONCRETF PLATFORM iiiiVeaft r� c etfts efti../fts on ai-Roft,4,47 `- �- �` EXISTING 0 WIRELESSEOUIPMENT CABINETS, TYPMileMarillerWft OA"1"V*18W. 41411 glWalallillaaNtiftilat44111/1111111/ i -- NW QOS4 EXISTING VERIZON WIRELESS ELECTRICAL H -FRAME UTILIZE EXISTING VERIZON WIRELESS WAVEGUIDE BRIDGE TO ROUTE COAX TO MONOPOLE • • EXEXISTISTINGING ANTEN60'-0'NA MONOPOLE.ARRAYS • NOT SHOWN FOR CLARITY EXISTING WOOD UTILITY POLE . 1 •• EXISTING EQUIPMENT PAD W/H EQUIPMENT • EXISTING VOICESTREAM WAVEGUIDE BRIDGE • 0•7 p 0 1�— k i . 7 w a. CC 0 -EXOUISTNDINATIG ON MONIOPOLE EXISTING RETNNING WALL - EXISTING ELECTRICAL H -FRAME WITH ICE BRIDGE• lir /21/ EXISTING VOICESTREAM EOUIPMENT PAD WITH EQUIPMENT EXISTING SITE PLAN 22"34" SCALE: 318" = 1'-0" 11"17" SCALE: 3/15' = 1'-0" 1 O V W LDC THE CIVIL ENGINEERING GROUP Architectural Engineering Structural Survey 14201 NE 20001 St., HOD WOo4IINin.. WA 98072 Ph. 425.808.1888 Fx. 425.482.2891 wAw.LDCcorp.c0m DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 5-10-10 PRELIMINARY CONBTRUCTN)N BEW 0-15-10 REVISED COS BEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA98188 SHEET TITLE EXISTING SITE PLAN SHEET NUMBER A-1.1 2010 — 2:24pm — SFA Orillia Rood\Drawings \Construction\1080200—A1 —2.dwg EXISTING CHAIN LINK FENCE WITH PRIVACY SLATS l'AD//EQ(7/pMF CO"CRE PATFORM 1 PROPOSED MICROWAVE SUPPORT CABINET. SEE DETAIL ON A-3.1 EXISTING VERIZON WIRELESS RAISED PLATFORM WITH .EQUIPMENT CABINETS EXISTING ELECTRICAL , CABINET -EXISTING ;ERIZON I8 EOUIFMENI CCABINETS, fTP33 01441 PROPOSED EWP90 WAVEGUIDE 1/7' COAX ROUTED UNDER PLATFORM EXISTING VERIZON• WIRELESS SERVICE METER • ' EXISHNC VERIZON .WIRELESS ELECTRICAL ' H - TRAMS PROPOSEDEWP90 WAVEGUIDE 1/2" COAX ': TO FOLLOW EXISTING COAX ROUTING UTILIZE EXISTING VER1ZON WIRELESS WAVEGUIDE BRIDGE TO ROUTE COAX TO MONOPOLE EXISTING 60'-0" MONOPOLE EXISTING ANTENNA ARRAYS NOT SHOWN FOR CLARITY EXISTING VOICESTREAM WAVEGUIDE BRIDGE EXISTING MONOPOLE FOUNDATION• • PROPOSED 70. MICROWAVE EXISTING RETAINING WALL - EXISTING ELECTRICAL H -FRAME WITH ICE BRIDGE EXISTING TELCO PEDESTAL EXISTING WOOD UTILITY POLE\ � J ..1 'EXISTING EQUIPMENT PAD Wf[f1 EQUIPMENT • EXISTING VOICESTREAM EQUIPMENT PAD WITH EQUIPMENT PROPOSED SITE PLAN 22"44" SCALE: 3/8" = 1'-0" I 11'x17" SCALE: 3/16" =1'-0" 1 LDC TNf CIVIL ENGINEERING GROUP Architectural Engineering Structural Survey 11311 NE 2018!, St., 8100 PN. 125.806.1869 W000lnvae, WA 98072 FO. 425.482.2091 www.LDCcorp.com DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 519-10 PRELIMINARY CONSTRUCTION BEW 2 8-154 0 REVISED C09 SEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA98188 SHEET TITLE PROPOSED SITE PLAN SHEET NUMBER A-1.2 Jun 22, 2010 — 2:24pm :\2010\_Telecom\10-802 Verizon — SEA Orillia Rood\Drawings\Construction\10802 TOP OF EXISTING MONOPOLE 60'-0" AGL —EXISTING LIGHTNING ROD _ "Cr -Cr EXISTING 60'-0'--„,. MONOPOLE DISTING VERIZON WIRELESS EQUIPMENT CABINETS EXISTING T -MOBILE EQUIPMENT TABINET� EXISTING ELECTRICAL H -FRAME WITH ICE `, BRIDGE /-EXISTING RETAINING WALL 0: 0.0.30 ❑ ❑ 0 der TIP HEIGHT OF EXISTING VERIZON ANTENNA ARRAY di 60'-0" AGL RAD CENTER OF EXISTING T -MOBILE ANTENNA ARRAY AGL RAD CENTER OF EXISTING ANTENNA MOUNT (EMPTY) 38'-0" AGL EXISTING WOOD UTILITI POLE EXISTING ELECTRICAL CABINET --EXISTING VERIZON WIRELESS ELECTRICAL H -FRAME /UNK /�WIITH PRIVACYI N SLATS FENCE EXISTING GRADEA 0'-0" AGL Y EXISTING NORTHEAST ELEVATION (LOOKING SOUTHWEST) 22"34" SCALE: 114" = 1'-0" I 11 "x17" SCALE: 1/8" = 1'-0" 1 LDC IMF CIVIL ENGINEERING GROW. Architectural Engineering Structural Survey 14201 NE 200tH St., 8100 Ph. 425.1508.1069 VWRdM®a. WA 98072 FR. 425.482.2893 W W W.LDCcorp.com DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 51410 PRELIMINARY CONSTRUCTION BEW 2 &1510 REVISED COS BEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA98188 SHEET TITLE EXISTING ELEVATION SHEET NUMBER A-2 Jun 22, 2010 — 2:25pm ,-EXISTING RETAINING WALL TOP OF EXISTING hMONOPOLE 60-0" AGL -EXISTING LIGHTNING ROD -0- RAD CENTER OF PROPOSED 2'0 �VERIZON MICROWAVE ANTENNA 52'-0" AGL - 0- v TIP HEIGHT OF EXISTING VERIZON ANTENNA ARRAY 60-0" AGL PROPOSED MICROWAVE MOUNT PROPOSED EWP90 WAVEGUIDE 1/2" COAX TO BE ROUTED THROUGH EXISTING COAX PORT 1 -Cr EXISTING EXISTING MONOPOLE EXISTING VERIZON WIRELESS-, EQUIPMENT CABINETS EXISTING T -MOBILE EQUIPMENT CABINET EXISTING ELECTRICAL-. H -FRAME WITH ICE -.N. „z ti r I/ RAD CENTER OF EXISTING T -MOBILE ANTENNA ARRAY di 7'b 4" AGL RAD CENTER OF EXISTING ANTENNA MOUNT (EMPTY) 38'-0" AGL EXISTING WOOD UTILITY POLE PROPOSED MICROWAVE SUPPORT CABINET. SEE DETAIL ON A-3.1 -EXISTING VFRIZON WIRELESS ELECTRICAL N-FFAME PROPOSED EWP90 WAVEGUIDE 1/2" COAX TO FOLLOW EXISTING COAX ROUTING 11.16- 6SL1 EXISTING CHAIN LINK FENCE WITH PRIVACY SLATS EXISTING GRADE 0'-0" AGL PROPOSED NORTHEAST ELEVATION (LOOKING SOUTHWEST) 22"x34" SCALE: 1/4" = 1'-0" I 11'517" SCALE: 1/8" = 1'-0" 1 0 V J W LDC THF GrvR ENGINEERING GRDUr Architectural Engineering Structural Survey 14201 NE 200th Si, 4100 P5. 425809.1869 WOO4AVWe, WA 98072 FR. 425.482.2899 www.LOCc0rp.ccm DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 5-19-10 PRELIMINARY CONSTRUCTION SEW 2 615-10 REVISED COS SEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA 98188 SHEET TITLE PROPOSED ELEVATION SHEET NUMBER A-2.1 E • o 0 u t 0 LDC Architectural Engineering Structural THE CIVIL ENGINEERING GROUT Survey 14201 NE 269h St.. 0100 Ph. 425808.1889 Woodinville. WA 98072 FR. 425.4822893 www.LDCcorp.com DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 5.1910 PRELIMINARY CONSTRUCTION BEW 2 &15-10 REVISED CDS BEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA 98188 SHEET TITLE ANTENNA DETAILS SHEET NUMBER A-3 V o I PROPOSED VERIZON MICROWAVE ANTENNA INFORMATION QUANTITY MODEL SIZE RAD CENTER AZIMUTH TILT 1 HP2-1011 70 52'47 AGL 75.51' 0.31° PROPOSED COAX LENGTH SCHEDULE SECTOR TYPE LENGTH # COAX DIAMETER MICROWAVE EWP90 WAVEGUIDE 80'-0" 1 1/2" NOTE 0 ry i °1L SEE MICROWAVE ANTENNA MOUNT DETAIL ON THIS SHEET MANUFACTURER: RADIO WAVES MODEL: HP2-1011 ...41% Al INC. I PROPOSED COAX ROUTING TO MATCH EXISTING COAX ROUTE. SEE MICROWAVE ANTENNA MOUNT DETAIL ON THIS SHEET PROPOSED MICROWAVE ANTENNA I NOT TO SCALE 3 PROPOSED VALMONT MONOPOLE, NOTE 15.51 MV'(H Av +- �� �� \`{ sk•� PROPOSED HP2-1011 20 ANTENNA @! AGL RAD CENTEREXISTING • UNIVERSAL RING MOUNT EQUIVALENTEXISTING !. PROPOSED VALMONT UNIVERSAL RING MOUNT EQUIVALENTI'-,,.Z.. ••� \4riIl PROPOSED 2-3/8"0tl PIPE MOUNT MONOPOLE !` IMICROWAVE , ,52-0" =`:e PROPOSED STANDOFF ANTENNA PROIPOSED 2-3/8"0 is VALMONT 8" ARM FOR SINGLE OR EQUIVALENT PIPE MOUNT ...- J _: PROPOSED ANTENNA TIE BACK IF APPLICABLE PROPOSED VALMONT 8" - STANDOFF ARM FOR SINGLE , ANTENNA OR EQUIVALENT I PROPOSED MICROWAVE ANTENNA EXISTING PANEL ANTENNAS AND MOUNT NOT SHOWN FOR CLARITY. PROPOSED ANTENNA PLAN NOT TO SCALE 2 PROPOSED MICROWAVE ANTENNA MOUNT I I NOT TO SCALE 1 0 u t 0 LDC Architectural Engineering Structural THE CIVIL ENGINEERING GROUT Survey 14201 NE 269h St.. 0100 Ph. 425808.1889 Woodinville. WA 98072 FR. 425.4822893 www.LDCcorp.com DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 5.1910 PRELIMINARY CONSTRUCTION BEW 2 &15-10 REVISED CDS BEW SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA 98188 SHEET TITLE ANTENNA DETAILS SHEET NUMBER A-3 • 2010-2:25Gm — SEA ON6a Road\Dmwmgs\Construction\10 •0 PAD LAYOUT VIEW REAR 24.67 4X 1.50 M 22.50 FRONT ### LEFT VIEW 41.1 O O O 0 O 0 O O .0 TOP VIEW (DOORS OPEN) FRONT VIEW RIGHT VIEW 0 0/ n i-rrm mlim 0 r` 30.0 8.0 • i.-1 38.1 REMOVABLE TOP CAP (ALARMED) MODULAR TOP CABLE RACEWAY (RF -TOP) 42U 23" EIA -STANDARD RACK -SPACE TOTAL 26U 23" AVAILABLE WITH TWO BATTERY BOXES REAR VIEW (DOORS REMOVED) 26.0 DOOR OPENING WIDTH \ • • QI / I 1 1: I :1 1 1: 2U BREAKER PANEL OPENING HEIGHT / • 1 u 1 • P-t„11111,1*dr FRONT DOOR WITH EMERGENCY VENT SYSTEM (EVS) BLANK COVER PLATES (4X) REAR DOOR WITH AIR CONDITIONER EXTENDED FOOTPRINT PLINTH (OPTIONAL) 2X ZONE 4 CERTIFIED BATTERY BOXES 4X 200A BETTERY BREAKERS (ALARMED) & CONNECTION CABLES (2X 24V STRINGS) MICROWAVE SUPPORT CABINET NOT TO SCALE 1 0 W LDC THE CNA ENGINEERING GROUP Architectural Engineering Structural Survey 11701 NE 200h St_ 8100 Ph. 025.008.1889 Woodinville, WA 98072 FR. 425.482.2893 www.LDCcorp.com DATE: 5-19-10 DRAWN BY: CAL CHECKED BY: BEW REVISIONS REV DATE DESCRIPTION BY 5-19-10 PRELIMINARY CONSTRUCTION BEW 2 8-1510 REVISED COS BEW i SITE SEA ORILLIA RD 18700 ORILLIA RD S TUKWILA, WA98188 SHEET TITLE CABINET DETAILS SHEET NUMBER A-3.1