HomeMy WebLinkAboutPlanning 2019-01-10 Item 4 - Staff Report - Memory Care Assisted Living Facility Design ReviewAllan Ekberg, Mayor
Department of Community Development - Jack Pace, Director
Staff Report
Board of Architectural Review for Holden of Southcenter Assisted Living
Prepared for the January 10, 2019 Meeting
FILE NUMBERS: L18-0087 Public Hearing Design Review
L18-0081 Special Permission Parking Determination
L18-0086 Shoreline Substantial Development
APPLICANT:
REQUESTS:
LOCATION:
COMPREHENSIVE
PLAN AND ZONING
DESIGNATION:
SEPA
DETERMINATION:
NOTIFICATION:
Alex Dalzell, Urbal Architecture, LLC
Design review to construct a seven -story building for a 122,918
square -foot assisted living community, to include 107 assisted living
units, 27 memory care units, and 58 parking spaces.
112 Andover Park E., Tukwila WA (parcel # 022300-0045)
Tukwila Urban Center — Transit Oriented Development (TUC-TOD)
Exempt: The City of Tukwila prepared a Supplemental
Environmental Impact Statement (SEIS) for the Southcenter
Subarea under the State Environmental Policy Act (SEPA) as set
forth in RCW 43.21C.420. Project -specific development proposals
within the Southcenter Subarea are not subject to individual SEPA
review provided they are consistent with the subarea plan,
development regulations, and the SEIS. This project is therefore
exempt from SEPA review.
A Notice of Application was issued on October 1, 2018, distributed
to owners and tenants of nearby properties and relevant agencies,
and posted on the project site. Two comments were received which
are described in this staff report. Notice of BAR public hearing was
posted on December 27, 2018, mailed to property owners and
businesses within 500 feet of the property, and posted on site.
RECOMMENDATION: Approval with conditions.
STAFF:
Lynn Miranda, AICP, Senior Planner
3
ATTACHMENTS:
A. Design Review Application, dated September 10, 2018
B. Parking Determination Staff Report, dated November 27, 2018
C. Parking Determination Notice of Decision, dated December 7, 2018
D. Shoreline Substantial Development Staff Report, dated December 3, 2018
E. Shoreline Substantial Development Permit Notice of Decision, dated December 3, 2018
F. Design Review Narrative prepared by Urbal Architecture, dated September 7, 2018
G. Tukwila Neighborhood Corridor Standards TMC Figure 18-23
H. Plan Set dated December 21, 2018
BACKGROUND
Vicinity/Site Description
Project Description
This project seeks to redevelop a 1.14-acre site with a seven -story, 122,918 square -foot assisted living building
located at 112 Andover Park E, parcel #022300-0045. The project includes 27 memory care units (Level 2), 107
assisted living apartments (Levels 3-7), 58 surface parking spaces, at -grade amenity spaces, landscaping, indoor
and outdoor open space, and frontage improvements. Amenity spaces include a ground floor cafe, outdoor garden
on Level 2, and roof deck on Level 5. The existing one-story building on the site will be demolished. One access
point (one-way, entrance only) is proposed off of Andover Park East and two access points are proposed off of
Christensen Road (one-way entrance and exit).
Zoning
The project is located within the Tukwila Urban Center -Transit Oriented Development (TUC-TOD) zoning
district, the area extending from the bus transit center on Andover Park West eastward towards the Sounder
commuter rail/Amtrak station. TMC 18.28.040 describes the TUC-TOD district as an area intended to provide a
more compact and vibrant mix of housing, office, lodging and supportive retail and service uses. Parking in the
district is intended to be accommodated by a combination of off- and on -street parking spaces. The overall
structure of the TOD Neighborhood will
be characterized by moderate
development intensities and building
heights. A fine-grained network of
streets with pedestrian amenities will
increase the walkability of the area.
The Green River is just east of
Christensen Road, which puts a portion
of the subject property within the 200-
foot shoreline overlay jurisdiction.
ix Nu„ Ir„",,iiiuYMV VVIGI
Site and vlil hity
t
r
add
4
200' from
OHWM
I'F , ,t IIIhorelllliinm;µ ingisdklion III':P m,mndar
125' from OHWM (east
side of Christensen Rd.)
Existing Development
Existing development on the project site consists of a 17,588 square -foot one-story vacant retail building,
originally constructed in 1966, which is proposed to be demolished. The building is primarily surrounded by
concrete and minimal landscaping. The 1.14-acre parcel is zoned Tukwila Urban Center -Transit Oriented
Development (TUC-TOD). Both Andover Park East (adjacent to the project sites west property line) and
Christensen Road (adjacent to the project sites east property line), are classified as Neighborhood Corridor.
11Ii 111111111111111111111111111111111111111111
y,r
I! dstiiun; sing Ill dying nurtllhm
1111111idsting st m;µ III III iiung g
Surrounding Land Use
Land uses in the nearby area are generally a mix of warehouse, retail, and office uses, with a growing residential
population. Land uses immediately adjacent to the property include:
• North: Hotel (Holiday Inn Express)
5
• West: Retail (Lowe's Home Improvement)
• South: Office (Fedex)
• East: Green River Walking/Pedestrian Trail
Topography & Vegetation
The parcel is generally flat. A grade change of approximately 5 feet exists at the east property line abutting
Christensen Road where a rock wall separates the site from the street above. The eastern portion of the site will be
partially re -graded to allow vehicular access to Christensen Road.
Access
The site currently has two vehicular access points from Andover Park E. There is currently no access off of
Christensen Road. The project proposes to keep one of these access points off Andover Park East, located at the
southwest corner of the property, and proposes to provide two new access points off of Christensen Road. All
proposed access points will be designed for one-way traffic; with an entry point off Andover Park East, and one
entry and one exit at Christensen Road.
DESIGN REVIEW FINDINGS
Design Review
This project is subject to Board of Architectural Review approval under Tukwila Municipal Code (TMC)
18.28.030.D. New residential buildings with more than 50 dwelling units are considered large-scale projects. As
a large-scale project, the proposal is subject to TMC Chapter 18.28, and the guidelines set forth in the
Southcenter Design Manual. Sections I -III below include a discussion of project consistency with the
requirements of TMC Chapter 18.28 including, District Based Standards, Corridor Based Standards, and
Supplemental Standards. Section IV is a discussion of project consistency with the Southcenter Design Manual.
The standards can be found online at
http://www.tukwilawa. gov/wp-content/uploads/DCD-Planning-TMC-18.28-Tukwila-Urban-Center.pdf
and the Design Manual can be found at
http://www.tukwilawa. gov/wp-content/uploads/DCD-Planning-Southcenter-Design-Manual.pdf
District -Based Standards
Structure Height (TMC 18.28.070): The maximum building height in the TUC-TOD District is 45
feet, and up to 70 feet with the multi -family height incentive, and 115 feet when incentives for both
multi -family and frontal improvements are met. The proposed building is a 70-foot multi -family
structure meeting the maximum allowable height. Stair and elevator tower/overrun areas project
approximately 9 feet above the 70-foot roof height and are exempted from height limitations per TMC
18.50.080.
Portions of the building are located within the 200-foot shoreline jurisdiction ofthe Green River, which
has a height restriction of 45 feet. The building steps down toward the east; the portion within 200 feet
of the Ordinary High Water Mark (OHWM) of the Green River is 41'-6", in compliance the height
requirement in the city's shoreline regulations in TMC 18.44.
Maximum Block Face Length (TMC 18.28.080): The proposed building is in compliance as it does
not exceed the 700-foot maximum block face length.
6
Side and Rear Setbacks and Landscaping Requirements (TMC 18.28.100-.110): The proposal
meets the 5-foot side and rear yard setback as required in the TOD district. A 5-foot landscaping area
is required in side and rear yard setback areas. Both side and rear setback and landscaping requirements
may be waived as part of design review if Building and Fire Code requirements are met. The Building
Division and Fire Department have reviewed and approved design of the project per applicable
Building and Fire code requirements.
II. Corridor -Based Standards
Both Andover Park East and Christensen Road are designated as Neighborhood Corridors, according
to Figure 18-23 of the Tukwila Municipal Code. See Attachment E for Neighborhood Corridor
standards summary sheets.
a_ is I�IIIIW 44. ,.,47
�fPl"0I,14�111i
III'�ir
NIIIYiiiii1ffi 111
II rd tiiung condition of Andover IPa rllla. IIR a t, Illo ling north
rimnglll°mllluaurllhood Caurr dour standard
Public Frontage Standards (TMC 18.28.150): Proposed public frontage improvements to both
Andover Park East and Christensen Road meet the public frontage standards required for
Neighborhood Corridors. The following public frontage standards apply to this project:
• Minimum 15-foot Public Frontage: The proposal meets this standard for both the Andover Park
East and Christensen Road frontages. The 15-foot public frontage standard requires 15 feet of
public frontage in the form of sidewalks and landscaping. On Andover Park East, a combination
of sidewalk and street trees within tree wells result in up to 20 feet of frontage. On Christensen
Road, varying landscape and sidewalk widths result in the required public frontage. Portions of
the sidewalk are tapered down to match the adjoining sidewalk at the recently constructed
Holiday Inn. Christensen Road is permitted to include a landscape strip rather than tree wells,
because on -street parking is not feasible on Christensen at this time.
• Street trees, located at the back of curb face: The proposal provides street trees along both road
frontages, located at the back of curb face, which buffer pedestrians from street traffic. Street
trees located along Christensen Road generally meet the requirement to be placed at back of curb
face, with the exception of trees located at the back of sidewalk where a pedestrian plaza is
proposed. On Christensen Road, proposed trees are included in perimeter landscaped areas along
with shrubs, groundcover, lights, benches, and a pergola, which create a quality pedestrian
environment that meets the intent of the design standards and also creates a more substantial
buffer to screen the surface parking lot and project lighting from the river. Per the City's
shoreline regulations, the trees, shrubs, and ground cover along Christensen are native species.
7
• Tree spacing 20-30 feet: Proposed street trees along Andover Park East and Christensen Road
are evenly spaced at 30 feet. The proposed tree species and placement have been reviewed by
the City's Urban Environmentalist. The Fraxinus lotifolia (Oregon ash) trees proposed along
Christensen Road at 30 feet on center have a typical spread of 35 feet. The Cercirdiphyllum
japonicum (Katsura tree) trees are proposed along Andover Park East, and are spaced at 30 feet
on center and have a typical spread of 25 feet. A spacing of 30 feet on center is an appropriate
spacing for both of these large stature trees to achieve desired tree canopy cover along the
corridor. Along Christensen Road, however, a few of these street trees are located at the back of
sidewalk rather than the back of curb face, for reasons stated above.
• Pedestrian and vehicular -scale decorative street lighting: A lighting plan was submitted (see
Sheet ADR 1.10 of Attachment F). Pedestrian -scale light poles consistent in style to those being
installed as redevelopment occurs throughout the TOD district are proposed along both Andover
Park East and Christensen Road. In addition, bollard lights are proposed to be installed along
pedestrian walkways, and up -lights are proposed at various landscaped areas to highlight
vegetation. Additional pedestrian scale lighting is provided in the surface parking lot. The
lighting shall be installed along the frontage per the Department of Public Works standard. The
project's proposed lighting fixtures are Dark Sky compliant and screened to control glare.
The stated intent of the Neighborhood Corridor, per Figure 18-23, is "to provide an intimately -scaled
pedestrian environment within northern Southcenter's higher density mixed -use neighborhoods, in a
`complete streets' setting with on -street parking and bicycles sharing the roadway with vehicles." The
proposed street frontage improvements greatly enhance the streetscapes of the site and provide an
appropriately -scaled and safe pedestrian environment. The frontage design also supports the potential
for street parking if that option is pursued in the future.
Building Orientation/Placement & Landscaping (TMC 18.28.160-.190): The proposed project
meets the building and orientation standards. The Neighborhood Corridor standards require building
orientation to the street. The primary building entrance is proposed to be located on Andover Park East
and the building is oriented this direction with the building placed up to the edge of the sidewalk, with
a distinctive building entrance.
While the building is primarily oriented toward Andover Park East, elements of building orientation
are also included on the Christensen Road frontage, including a resident entrance facing the street that
is recessed and weather protected. Front yard setbacks, parking location, and landscaping are separate
requirements that are discussed in following sections.
Per Figure 18-23 of the Tukwila Municipal Code, the following building orientation standards apply to
this project.
• Building orientation to streets/ open space: The building is primarily oriented toward
Andover Park East and is designed to create an urban edge along this street. The primary
entrance is located at the southwest corner of the building and connects directly to Andover
Park East. A secondary entrance is provided facing Christensen Road underneath a
cantilevered portion of the building. Per 18.28.160, "where building orientation to streets is
required for the applicable Corridor Type, weather protection at least 6 feet in width along
at least 75 percent of the face must be provided. The applicant has provided weather
protection with steel and glass canopies, located near main entries. The canopies along
Andover Park East amount to approximately 217 feet of protection, greater than the required
75 percent. Less than 75 percent is proposed on the eastern facade, although this requirement
8
is waived as this is not the primary building entrance. This entrance is primarily designed
for use by residents.
• 15-foot front yard setback minimum: The project meets the requirement. Within the Tukwila
Urban Center, setbacks are measured from the existing curb face, as right-of-way varies
from parcel to parcel. Along Andover Park East, the building is setback 18 feet from the
existing curb face. A portion of the sidewalk and street trees required to meet the public
frontage requirement are located within right-of-way. On Christensen Road, the building is
setback approximately 67 feet from the curb line.
• On -site surface parking located in side or rear of building: The proposal meets this
requirement for the Andover Park East frontage, but modifications were required for the
Christensen Road frontage.
Per TMC 18.28.190.B.3, for a street to be designated as a Neighborhood Corridor, parking
between the building and the back of sidewalk is limited to a maximum depth of 63 feet, the
width needed for a double -loaded aisle of parking. The building is setback further than 63
feet from Christensen Road. The width of the site is narrow, and is further constrained by
the shoreline jurisdiction which covers the eastern half of the site, which requires a
maximum height of 45 feet. These constraints make it difficult to locate a building on -site
that is consistent with the underlying zoning's maximum parking depth requirements and
the shoreline height regulations while furthering the goals of the Southcenter Plan's TOD
District for increasing the amount of higher density redevelopment. Consequently, the
project exceeds the maximum 63-foot depth limitation for surface parking of the underlying
zoning but mitigates the impact by constructing a wider sidewalk and landscape area on
Christensen to screen the shoreline from the parking area and create a more continuous and
improved sidewalk amenity.
Overall, the proposed building location and parking location provides a balance between the
zoning requirements on the site and protection of the adjacent shoreline.
• 15-foot front yard landscaping minimum: Along, Andover Park East, the applicant is
providing 18 feet of public frontage inclusive of sidewalk area and street trees. Along
Christensen Road, some landscaped areas are up to 13 feet in width and the combined
sidewalk/landscape frontage areas are 22 to 28 feet. Per 18.28.160, the requirement for 15
feet of streetscape landscaping has been waived because the public frontage has been built
to the corridor standard.
Architectural Design Standards (TMC 18.28.200
Neighborhood Corridor
Architectural Design Standards
Design Response
Acceptable
Partial
Not Applicable
Facade Articulation Increment
Residential maximum — 30 ft.
X
Major vertical modulation maximum — 120
X
Ground Level Transparency
Neighborhood Corridor
Commercial -use minimum — 50%
X
"'t"'TIbllm;» :.: AurcIh tec tuuralll IIDesilguin Standards four the IIrtt gllhbaurlhood Carnldaur
9
III. Supplemental Standards
Special Corner Feature (TMC 18.28.220): The building has two frontages; Andover Park East and
Christensen Road. The site is located midblock on both streets between Tukwila Parkway and Baker
Blvd. As such, the building is not required to incorporate a special corner feature to emphasize the
building at an intersection.
Landscaping Types and General Landscaping Requirements (TMC 18.28.230-.240): Front yard
landscaping requirements along Andover Park East and Christensen Road include 15 feet of
streetscape. Public frontage improvements are proposed to be constructed along both Andover Park
East and Christensen Road, to consist of a combination of landscaping and sidewalk areas. Parking lot
perimeter and internal landscaping is proposed.
Along Andover Park East, the proposed configuration and width of the public frontage meets the
Neighborhood Corridor Standard (see Attachment E). Proposed planting species and spacing have been
reviewed by the City's Urban Environmentalist. The Neighborhood Corridor Standard requires tree
spacing of 20 to 30 feet depending on species. Sheet ADR L1.00 of Attachment F shows trees and
groundcover at 30 feet on center. The Cercirdiphyllum japonicum (Katsura tree) trees proposed at 30
feet on center on Sheet ADR L1.00 of Attachment F have a typical spread of 25 feet. A spacing of 30
feet on center is an appropriate spacing for this large stature tree to achieve desired tree canopy cover
along the corridor. The Fraxinus lotifolia (Oregon ash) have a typical spread of 35 feet and are also a
large stature tree where a spacing of 30-feet on center is appropriate.
Plantings along Christensen Road include Fraxinus lotifolia (Oregon ash) trees, Acer circinatum (Vine
maple) trees, and Tsuga mertensiana (Mountain Hemlock) trees. The total tree coverage exceeds that
which would otherwise have been planted at the Neighborhood Corridor Standard, and provides
additional buffering of the shoreline from the proposed development. A modification is proposed to
place street trees behind the sidewalk rather than
at curb face. This modification meets the intent of
the Neighborhood Corridor in providing an
"intimately -scaled pedestrian environment", due
to the provision of pedestrian amenities designed
to create a pedestrian plaza area, as shown on
Sheet ADR L1.00 of Attachment F. These
amenities include benches, a bike rack, and a
pergola, as well as the creative landscape features
including landscape block walls, raised planters,
and planting areas with additional native shrubs
and groundcover. Staff recommends approving
the modifications to the frontage requirement to
allow for the provision of additional landscaping
to serve as a buffer to the shoreline and to
compensate for the modification to the internal
parking lot landscaping requirements discussed
below.
Proposed I°lan caIlpiing liiuna::lllam ilung a::Oamu
curd area
The proposed parking lot includes space for 58 vehicles. A minimum of 20 square feet of internal
parking lot landscaping is required for each parking stall. A five foot perimeter landscape setback is to
be provided from the Corridor back of sidewalk. A total of 2,670 square feet of parking lot landscape
area is provided. Surface parking lots are required to be set back a minimum of five feet from the
Corridor back of sidewalk. In order to allow the building to be setback as far as possible from the
10
shoreline 200' buffer, the parking area, which otherwise would have to have been constructed as one
double loaded drive aisle between the building and street, was reconfigured to accommodate pushing
the building away from the shoreline and towards Andover Park East (which also serves to create an
"intimately -scaled pedestrian environment").
Per TMC 18.28.240.4, all required plantings are shown as served by a permanent automatic irrigation
system, except for the proposed parking lot landscape island. As a condition of approval, irrigation
must be added to this area. Per TMC 18.28.240.B.3, the project must meet the requirement to provide
"CU" soils for trees and plants planted in sidewalks and parking lots.
Landscape Modifications
A modification is requested for complying with the parking lot landscaping. The proposal does not
provide landscape islands that meet the minimum 100 square -foot requirement, including the
requirement for one large or two medium canopy trees per every 100 square feet of landscape island.
However, this is offset by enhancing the parking lot perimeter with additional landscaping and
receiving credit for retaining significant trees (see Sheet ADR L1.06 and ADR 3.00).
The perimeter modification request meets the following criteria contained in TMC 18.52.100.B and
may be approved, as:
i. The modification does not reduce landscaping to the point that activities on the site become
a nuisance to neighbors; and
ii. The modification does not diminish the quality of the site landscape as a whole; and
iii. The modification more effectively screens parking areas. In this case, the parking lot is more
effectively screened from the Green River Trail and pedestrian area.
Using the criteria in TMC 18.52.100.F, credit for retained significant trees may be counted towards
the project's required landscaping as:
i. A certified arborist has assessed the three large Leyland cypress trees in the southeast corner
of the site as in "good" health and structural condition; and
ii. Retention of the trees support the Tukwila Urban Center Comprehensive Plan urban tree
canopy goals and policies; and
iii. A financial assurance will be posted based on 50% ofthe value ofthe retained trees to ensure
tree replacement should the retained trees be damaged or die as a result of construction
impacts. The financial assurance shall be retained for three years; and
iv. The value of the trees to be retained, as determined by the certified arborist, shall be posted
on the tree prior to site preparation and retained throughout the construction of the project.
Open Space Regulations (TMC Table 18-4, TMC 18.28.250): The project exceeds the required
amount of open space, and generally meets or exceeds the requirements of this section of the code. The
required amount of open space for residential projects is equal to 10% of the residential unit floor area,
and may be any combination of common or private open space. The gross floor area of residential
unit floor area is 83,800 square feet. Based on this square footage, 8,380 square feet of open space is
required. The open space provided on site is a combination of outdoor and indoor common Outdoor
open space includes a 3,065 square foot memory care garden on Level 2 and a 1,945 square foot
landscaped patio on Level 5. Indoor amenity spaces are proposed on Levels 1, 2 and 5, and include a
living area, wellness center, discovery room, , and a multipurpose space, totaling approximately 5,900
square feet. The overall combination of outdoor and indoor spaces is approximately 8,900 square feet,
which exceeds the minimum open space requirement.
General Parking Requirements and Guidelines (TMC 18.28.260-.270): The proposed project
provides 58 total parking stalls. Table 18-5 of the TMC lists parking requirements for several common
11
land uses. However, the required number of parking stalls for assisted living and memory care units
are not specified by the City's parking regulations. For uses not specifically mentioned in Table 18-5,
the parking requirements are to be determined by the Department of Community Development Director
as a Type 2 Special Permission decision (City file number L18-0081). Based on the analysis within the
Special Permission Parking Determination, it was determined that 0.43 parking spaces per dwelling
unit are required. With 134 total units, 58 parking stalls would be required. The proposed project meets
this requirement. A complete discussion of the applicant's Special Permission request, project
consistency with decision criteria, and staff recommendations are included within the Special
Permission Parking Determination in Attachment B.
A total of 6 covered, ground -level bicycle parking spaces are required per code. Bike storage for six
bicycles is provided under the covered portion of the parking lot on the east side of the building, as
depicted on Sheet ADR 1.00 in Attachment F.
A maximum of two one -lane curb cuts are permitted for each 500 linear feet of street frontage. Two
one -lane curb cuts are proposed on Christensen Road to provide entrance and exit to the site. On
Andover Park East, a single, one -lane driveway is proposed to provide entrance to the site. All vehicles
exiting the site would exit onto Christensen Road. The sidewalk detail for driveway areas conforms to
TMC 18.28.260.C.1.c, which requires the curb cut design for driveways on Neighborhood Corridors
to match the height of the sidewalk to ensure that the sidewalk stays at a consistent grade for
pedestrians.
A minimum 6-foot hard -surfaced walkway is provided through the parking lot to the main entrance
and connecting Andover Park East and Christensen Road, in accordance with TMC 18.28.260.D.5.
The trash and recycling area for the project is proposed within the first level of the building, where it
will not be visible from the public realm.
Site Requirements (TMC 18.28.280): Pedestrian access points to the building are provided at the
main entrance to the building at Andover Park East, and via a pedestrian walkway through the parking
lot to the main entrance from Christensen Road, meeting the intent of TMC 18.28.280.A.2. The
pedestrian walkway is distinguished from the parking area it crosses through the use of decorative
scored concrete. This walkway provides a connection from Andover Park East to the Green River
which previously did not exist. A recommended condition of approval has been included in this staff
report that signage is provided indicating the public nature of the walkway and its connection to the
river.
Lighting is provided in accordance with TMC 18.28.280.B at the building entrances (with decorative
sconces), recessed lights spaced approximately every 12 feet within the covered parking area, wall
sconces along the perimeter of the building, pedestrian bollard lights within the pedestrian walkway
and seating areas, and pedestrian light poles within the parking lot and along Andover Park East and
Christensen Road. Mounting height does not exceed 14 feet for building mounted lights and 20 feet
for pole mounted lights as is prescribed within the TOD District.
A 24-inch tall landscape block wall is proposed along the east boundary of the parking area to resolve
an existing topographic change of approximately 5 feet between the sites eastern and western
boundaries. The garbage and recycling facilities are proposed inside the ground floor of the building,
screened from the public realm. Mechanical equipment such as a transformer and emergency generator
are proposed to be screened by landscaping and a wooden screening fence.
12
IV. Southcenter Design Manual
The Southcenter Design Manual guidelines support and complement the community vision described
in the Southcenter Subarea Plan, supplement and expand upon the design requirements in Chapter
18.28, and provide a flexible tool for quality and innovation. The Design Manual is organized into two
main sections: Site Design Elements and Building Design.
Site Design Elements covers a number of design topic areas, including Site Design, Service Areas and
Mechanical Equipment, Lighting, Walls and Fences, and Open Spaces. The section on Building Design
covers Architectural Concept, Entrances and Doors, Building Facade — Base and Top, Corner
Treatments, Building Massing, Building Details and Elements, Building Materials and Colors,
Windows, Weather Protection, Blank Walls, and Parking Structures.
For each topic area, there are one or more Design Criteria, which can be general in nature. The Design
Criteria explain the requirements for development proposals. They are the decision criteria by which
the Director or Board of Architectural Review will decide whether to approve, approve with conditions
or deny a project. The examples and explanations which augment each Design Criteria provide
guidance to the project applicant, to City Staff in reviewing a project proposal, and to the decision
maker in determining whether the project meets the Design Criteria.
A. Site Design /Elements
1. Site Design
The intent of the site design/elements criteria is to encourage site design which is easily
understood, appropriate to the area, takes advantage of unique opportunities, and is a
positive element in the architectural character of the District within which it is located.
The design criteria address various elements including: facilitation of traffic circulation
by connecting through -streets; provision of safe, convenient, and connected pedestrian
access; encouragement of harmonious visual character (where desirable); arrangement
of buildings to enhance street frontages and the pedestrian environment; incorporation of
open space and landscaping as a unfing feature; incorporation of screening,
environmental mitigation, utilities and drainage as positive design elements;
incorporation of opportunities for joint development of sites; and the use of site design to
take advantage of and/or enhance views of and access to natural amenities such as the
Green River.
The project meets the design criteria. The design of the site is sensitive to the context of the
site, including orientation to both streets, connection to the Green River, compatibility with
surrounding developments, and pedestrian -friendly perimeter landscaping.
The site must comply with both the Tukwila Urban Center and the Shoreline design criteria,
and the applicant had to strike a balance between the two codes, with priority given to
meeting the requirements of the Shoreline Jurisdiction, which is state mandated. The eastern
portion of the site is within the 200-foot shoreline jurisdiction, and as such the building was
located at the western portion of the site to ensure it would comply with the 45-foot building
height maximum in the area between 150 and 200-feet of the OHWM.
13
r /WrlyCM /6; FAMOdr ' "
Proposed e site design
Although an increased setback from Christensen Road was necessary, the site design still
provides orientation toward the Green River in accordance with shoreline design
requirements. The east side of the building enhances views to the river with windows and
patios. The site also provides enhanced pedestrian access from Andover Park East to the
riverfront park area.
Other project features that meet the design criteria include:
• Street trees located on both site frontages, spaced at 30 feet on center, and located in tree
pits to provide potential for street parking in the future.
• A landscaped pedestrian connection proposed along the southern side of the lot, linking
Andover Park East to the Green River Trial and riverfront.
• Densely vegetated landscaping along Christensen Road that creates a buffer and provides
an amenity to the community as well as the riverfront ecosystem.
• A "step-down" tiered massing of the building facing the Green River.
• Similarity in scale and building materials with recent redevelopment projects in the
vicinity.
2. Service Areas and Mechanical Equipment
The intent of the service areas and mechanical equipment design criteria is to minimize
the potential negative impacts of service elements through thoughtful siting and
screening while meeting functional needs. Design criteria include: service element
location and design; minimizing public visibility of loading docks and service bays,
location and/or design of utility meters; electrical conduit and other service utility
apparatus; rooftop equipment screening; and concealment and design incorporation of
downspouts.
14
The project meets the design criteria. The trash and recycling facilities are fully located
within the building and all mechanical equipment is housed internally. Large rooftop
mechanical units will be screened in accordance with the design guidelines. The utility areas,
loading zones and trash pickup have been consolidated in one area on the east end of the
building to be as discrete as possible. Vehicular access will be a one-way entrance off of the
Andover Park East, and will exit onto Christensen Road in the east, which is a dead-end
street.
3. Lighting
Site lighting should be designed to promote safety as well as enhance the nighttime
appearance of buildings and landscaping.
The project meets the design criteria. The applicant submitted a lighting plan that includes
seven different types of exterior lights and pedestrian -oriented street light poles. The light
fixtures are modern, appropriately spaced (per public works criteria), and complement the
building as well as improve the street level pedestrian -experience. The project's proposed
lighting fixtures are Dark Sky compliant and screened to control glare.
ProPased IlboIIIlIIIa rm Illil 111°mm' IPa;»mom; st nlen Dent IpoIllle„ and scone Illilglll°mt
Other project features that meet the design criteria include:
• Exterior can light fixtures located at entry canopies.
• Bollard fixtures to illuminate designated pedestrian paths.
• Pedestrian -scaled lighting in the surface parking lot.
• Pedestrian -oriented street light poles on Andover Park East and Christensen Road
frontages.
• Exterior wall sconce lights along building base to illuminate ground -level brick portions
of facade.
• Lighting placed in landscape strips to illuminate sidewalks. Some uplights will be placed
in areas that highlight vegetation.
4. Walls and Fences
Walls and fences shall be designed to be compatible with the building, improve the
appearance of the site, and improve safety.
The project meets the design criteria. To soften the appearance of walls, a variety of materials
are used, such as masonry. The use of varying materials also creates a clear cap and base
treatment to the walls. The transformer/generator in the north of the site will be screened by a
vegetated hedge and a slatted wood fence. The site does not include any security fencing, and
refuse and mechanical areas are either enclosed in the building or located out of sight.
15
5. Open Space
Provide safe, attractive, and usable open spaces that promote pedestrian activity and
enhance the setting and character of the development.
The project meets the design criteria. The proposal includes common open space via a 5tn
floor deck and an internal courtyard area located on Level 2, which can be used by residents
for outdoor seating, relaxation and community gatherings. The Level 2 courtyard is intended
for memory care residents. At the perimeter of the site, landscaped pedestrian paths use an
attractive stamped concrete pattern, and include amenities such as street trees, pedestrian
scale lighting, benches, bike racks, and a pergola. The Christiansen Road frontage provides
more pedestrian space than the Andover Park East frontage, and transitions well to the Green
River Trail to the east.
11 Stu titi !„�0
f
Examplkes of amenities tor use ilui IlfpullbIlliic and private open space areas
B.
Building Design
1. Architectural Concept
The architectural design criteria encourages building design with easily understood
organization, an appropriate relationship to the site, and with a positive impact on the
architectural character of the District within which it is located. Architectural design
should unf the massing and components of a structure or structures on a site into a
cohesive and consistent thematic or stylistic architectural character or style that is
responsive to the functional requirements of the development.
The project meets the design criteria. The building has a clear and prominent front entrance
facing Andover Park East, with a recessed front entrance that connects to the public sidewalk,
and canopies, brick columns, and a sculpture feature. The building is located and oriented
toward Andover Park East to create a clear urban edge. Facing Christensen Road, the
building is setback with tiered modulation, and "steps down" toward the Green River. On this
side, greater perimeter landscaping is provided, which creates a softer edge along the more
natural environment. The scale of the building is appropriate given the surrounding urban
context and similar buildings in the area.
2. Entrances and Doors
The primary entrance should be located and designed to represent the overall style and
architectural character of the building and ensure a welcoming public face to the
building.
16
The project meets the design criteria. The building is oriented toward Andover Park East,
where there is a prominent entrance that is clearly discernable to the public. The entranced is
recessed with a porte cochere that connects directly to the street. The entrance is highlighted
by a large canopy and at ground level uses different, lighter materials and special paving that
welcome pedestrians from the street. On the Christiansen Road side, similar features are
used, such as wrapped canopy with signage and brick columns, however the design is more
subtle and promotes use by residents rather than the public.
Plenary m;cht rance on Southwest corner er of Il amillll ilui�
3. Building Facade — Base & Top
Create a building base where the horizontal articulation of the lower part of a building
facade's design establishes a human scale for pedestrian users and passers-by, and
aesthetically "ties" a building to the ground. Create a "top" on buildings through a
substantial horizontal articulation of the facade at the uppermost floor of the building to
provide an attractive facade skyline and complete the upper facade composition.
Rooflines should reflect the architectural style of the building and be a distinctive design
element. Roof surfaces should be punctuated with varying roof forms to break up large
massing of roof surfaces and/or to provide opportunities to daylight interior spaces. Roof
overhangs for both flat and sloping roofs are encouraged to add depth, shadow and
visual interest.
The project meets the design criteria. At the base, distinct brick materials are used at the first
two floors to "anchor" the building. Although the base level is not commercial in nature,
certain design features mimic a commercial environment that is distinct from the residential
look of higher floors. High levels of transparency are used at the ground level for a more
pedestrian -scaled environment. The southwest corner is chamfered to allow for a pedestrian
loading area and entry at ground level. Above the first two floors, a cornice with a wood
soffit is used to transition to the next levels of the building, where fiber cement panels and
cedar materials are divergent from the ground -level brick cladding. The building provides a
high amount of modulation, cornices, and a 5t' floor deck to add variety to the appearance of
these levels. A similar wood soffit and architectural concept is present at the top of the
building.
17
4. Corner Treatments
The design criteria serve to emphasize building corners at important intersections with a
distinctive building element.
The building has two frontages on opposite sides, and is not located at an intersection, so the
corner treatments as defined in the design guidelines are not applicable to this building. Still,
some corner features are present. The main entrance located at the southwest corner of the
building is chamfered and adjacent to a vehicular drive-thru and a pedestrian walkway
through the site. Windows at the corner of the building have a slightly different pattern and
trim.
5. Building Massing
The use of horizontal and vertical modulation is required to maintain the desired human
scale and character for the Southcenter area. The requirements encourage the design of
building facades which incorporate interesting architectural details that add variety to
the facade, animate the street presence, and are attractive at a pedestrian scale.
The project meets the design criteria. Both Andover Park East and Christensen Road are
Neighborhood Corridors, which require at least three design features spaced at a 30-foot
interval. The applicant has provided the following:
• Fenestration patterns: The largest windows are located at the base of the building to
increase transparency to the street front providing sightlines into and out of the building.
On residential floors, repeating windows are used that balance daylight with energy
efficiency. The appearance of the repeating windows is improved through the use of fiber
cement panel window trim, and 3-foot vertical modulation.
• Vertical modulation: The building facade utilizes multiple 3-foot insets which are
discernable by a change in material from white fiber cement panel to wood at the reveal
walls.
• Change in roofline form: On the facade facing Christensen Road, a "stepping skyline"
concept is used. Overall, a change in parapet is used to create a distinct roofline.
• Change in building material: In coordination with the creation of a "top" and "base",
varying building material and siding is used. The changes in materials also correspond
with vertical and horizontal building modulation.
411
l
MNYNwoWW :u
0
SourChwe m IIN'eursllp'ernive from Andover III'maurllIk. III'' fIst
111111111aIIIII mh1111UYrVIkIRd Yildp�������I�Ill1111111111
q"'
NNNN��NN�
Northeast t Ilfm'er llfm'm;µclilve from (°:IIIHril teun euim Illy m
18
The project complies with major vertical modulation design guidelines and requirements. On
the east side, the building stepbacks and projections are at least 10-feet deep and 20-feet
wide. On the west side, a contrasting vertical design is created by a 3-foot modulation and a
change in material. This element extends from the ground floor to roofline, at which point the
modulation incorporates a change in the cornice and roofline treatment.
6. Building Details and Elements
Detail elements are required to encourage the incorporation of design details and small-
scale elements into building facades that are attractive at a pedestrian scale.
The project meets the design criteria. Because the proposal is for a residential building, 6
(two details from each category) listed details and elements at a 30-foot articulation
increment must be present along any street -facing facade. The applicant has provided the
following:
• Window and/or entry treatment: The proposal provides elements (a) and (e).
o (a) Display windows divided into a grid of multiple panes: The largest windows
are located at the storefront level to provide transparency
o (e) Recessed Entry: The main entry to the building is recessed
• Building elements and facade details: The proposal provides elements (a) and (c).
o (a) Custom -designed weather protection element: Steel and glass canopies are
present at the main entries.
o (c) Decorative building -mounted light fixtures: Decorative wall sconce light
fixtures are provided across the streetscape to provide accent lighting at brick
portions of the building. A different sconce fixture is used at the building entries
for wayfinding purposes.
• Building materials and facade elements: The proposal provides elements (a) and (c).
o (a) Use of decorative, high quality building materials: A materials board was
submitted showing the use of high quality brick, concrete, and wood.
o (c) Decorative kick -plate, pier, beltcourse, or other similar features: Brick is used
at the building base which is broken up by storefront glass that sits on a concrete
curb. Wood is used for soffiting and building modulation to create a tactile and
natural material palette.
7. Building Materials and Colors
The use of natural materials that reflect our Northwest setting such as stone, local woods
like cedar and fir, and functional materials like concrete, brick, and metal are
encouraged. Wall cladding materials appropriate to the architectural style and building
type shall be used. Authentic materials and methods of construction should be used to the
degree possible. More than two colors and materials should be incorporated into each
building's design. Monochromatic schemes are discouraged. Color choices should
include warm rich colors that reflect and complement the woodlands, water and open sky
of the region; weathered wood and oxidized metal colors relate to industrial and
agricultural influences.
The project meets the design criteria. The applicant submitted a materials board showing
high -quality wood, brick and cement paneling. The color pallet uses dark earth tones and was
chosen to give the materials a natural look. The colors are warm and subtle, which allows the
19
building compatibility with both the urban and natural surroundings.
Other project features that meet the design criteria include:
• Ivory -colored fiber cement paneling that is modest in appearance and provides a
backdrop to building accents and building features.
• Brick material at the base of the building to provide a distinct, textured look at the
pedestrian level.
• Vertical and horizontal modulation made of cedar wood.
• Metal wall paneling to provide additional contrast.
• Fiber cement panel window trim.
8. Windows
Ornamental framing and hardware should be used to provide a utilitarian opportunity
for craftsmanship and decoration. Window frames and sills should be designed to be
prominent and substantial in order to enhance openings and add additional relief.
The project meets the design criteria. The architectural concept includes varying window
patterns and types of vinyl and trim depending on location. At the ground floor level, the
project utilizes large aluminum storefront windows. These windows provide over 50 percent
transparency from the street, as well as trespass of natural light. The ground floor windows
are more prominent than the residential windows on higher floors, and provide a "base" that
is distinct from the rest of the building.
Other project features that meet the design criteria include:
• Use of second floor black vinyl windows that complement the storefront windows below.
• Use of brick window base trim on the second floor.
• Use of fiber cement panel window trim along repeating residential windows and 3-foot
vertical modulation.
• Window placing designed to break up blank walls and provide natural daylight to rooms.
9. Weather Protection
Design buildings with non-residential ground floor uses to provide pedestrian weather
protection along adjacent street front sidewalks and open spaces using awnings,
canopies, or building overhangs such as porticos, covered porches and arcades. Where
building orientation to streets/open spaces is required for the applicable Corridor Type,
weather protection at least 6 feet in width along at least 75 percent of the facade must be
provided.
Weather protection features are designed as an architectural element and are provided at all
major entrances. The primary building orientation is located at the southwest corner facing
Andover Park East where steel and glass canopies are provided along approximately 217
linear feet, greater than the required 75 percent. Both the primary and secondary entrances
are located underneath cantilevered portions of the building. The canopy design includes
black metal that complements the black vinyl storefront windows.
20
Andover IPaurllla. street front desilgn
10. Blank Walls
Blank walls are not permitted facing streets, sidewalks, open spaces, or pedestrian
pathways and instead shall be designed to provide visual interest and human scale.
All four facades incorporate architectural features to soften the appearance of and add variety
to walls. The west and east street -facing facades include doors, windows, canopy elements,
and vertical modulation. On the north side of the building, large expanses of blank walls are
treated using vertical trellises with climbing vines and additional landscaping to in a 5-foot
wide planting strip. Along the south side, a pedestrian path passes by a chamfered corner
with windows and southwest facing main entrance.
11. Parking Structures
Design parking structures which are part of a new development to be architecturally
consistent with exterior elements of the primary structure, including roof lines, facade
design and finish materials. Design ground floors of parking structures that front on
Tukwila Pond or public streets in the TOD and Pond Districts to accommodate future
office, retail, or residential uses.
Not applicable; no parking structures are proposed.
V. Public Comments
A Notice of Application was distributed by mail on October 1, 2018 to owners and tenants of properties
within 500 feet of the project site, as well as agencies that may have an interest in the project. The
Notice of Application was also posted on the project site. Public comments were received during the
Notice of Application period from Karen Walter of the Muckleshoot Indian Tribe Fisheries Division
and Stephanie Jolivette of the Washington Department of Archaeology and Historic Preservation (DAHP).
These are included in the Shoreline Substantial Development Permit Staff Report found in Attachment C.
Comments and the applicant's responses are summarized below:
1. Ms. Walter commented that the non-native trees and shrubs within the regulated shoreline area
should be replaced with native species. The applicant has revised the landscape plan to include
native species in planting areas within the shoreline jurisdiction.
21
2. Ms. Walter was concerned that lighting on the eastern project site avoid indirect lighting to the
Green River and reduce contributions to nighttime sky lighting conditions. She commented that
the lighting plan, in combination with the replacement trees, should ideally reduce current
artificial lighting effects over existing conditions and, at a minimum, not make them worse. She
also suggested that native conifer trees, such as Western Hemlock, Douglas Fir, or Western Red
Cedar be substituted in the landscaping on Christensen Road to help with lighting screening.
The applicant responded that site lighting has been designed to meet the requirements of section
18.44.070.C.4 of the Tukwila Municipal Code. The design has considered both the requirement
to reduce the light spillover off the site and to meet the minimum lighting requirement for the
parking lot and public right of way. The proposed lighting is Dark Sky Compliant and screened
to control glare. The landscape plan has been revised to include Western Hemlocks, as
suggested, to screen project lighting.
3. Ms. Jolivette notified staff that according to the DAHP predictive model, the project is located in
an area determined to be of very high risk of containing archaeological resources. She requested
professional archaeological monitoring of all ground disturbing activities on the site. Prior to
ground disturbance, a professional archaeologist should develop a monitoring plan which
includes an Inadvertent Discovery Plan. She also recommends consultation with the concerned
Tribes' cultural committees and staff regarding cultural resource issues.
The applicant has engaged an archaeologist to prepare the on -site monitoring plan and inadvertent
discovery plan. As a condition of approval of the shoreline substantial development permit, before the
building permit is issued, the applicant will provide both the site monitoring plan and the inadvertent
discovery plan as a formal memo to city staff. The monitoring plan must also be delivered to DAHP
and shared with any concerned tribes.
CONCLUSIONS
District -Based Standards
Proposed use, structure height, maximum block face length, and setback requirements are in
compliance with the Tukwila Urban Center -Transit Oriented Development standards.
II. Corridor -Based Standards
Both Andover Park East and Christensen Road are designated as Neighborhood Corridors. The project
was reviewed for consistency with Neighborhood Corridor Standards in Tukwila Municipal Code
Figure 18.23. The proposed project meets the requirements for public frontage standards along
Andover Park East and Christensen Road, including configuration, width, landscaping, and street
lights.
The proposal meets Building Orientation/Placement and Landscaping standards regarding building
orientation, weather protection, minimum front yard setbacks, and front yard landscaping. Due to the
constraints of a maximum building height of 45-feet within 200-feet of the OHWM of the Green River
on the eastern half of the site, a modification was made to locate the bulk and taller portions of the
building adjacent to the back of sidewalk on Andover Park East. This has resulted in the amount of
parking between Christensen Road and the building to exceed the maximum double loaded aisle of
parking permitted for development fronting a Neighborhood Corridor. To mitigate the visual impacts
of the surface parking on the shoreline, the applicant's proposal increases the amount of parking lot
22
perimeter landscaping on the east side and a small pedestrian plaza on Christensen Road. This
modification allows the type of mixed use urban development envisioned for the TOD area, provision
of adequate parking, compliance with height requirements of the shoreline jurisdiction, and creation
of an urban, pedestrian -friendly street frontage along Andover Park East and an amenity for the
residents and the public on Christensen Road.
The proposal meets Architectural Design Standards including facade articulation increment of 30 feet,
major vertical modulation maximum of 120 feet, and minimum and ground level transparency. As a
residential building, the ground level transparency minimum of 50% would not apply, however the
proposal provides significant transparency (greater than 50%) along Andover Park East. Less ground
level transparency is provided on the eastern frontage, however, the property does not directly abut
the street.
III. Supplemental Standards
The proposal meets the requirements for general landscaping, parking and site design, and open space
requirements.
The following modifications are requested to depart from the supplemental standards including:
• Internal parking lot landscape island requirements are not met. A smaller island (2-feet wide) with
less landscaping than required is provided at the end of the parking stalls. The proposed
modifications include enhancing the parking lot perimeter with additional landscaping and
receiving credit for retaining significant trees. Approval of the proposed modifications is
recommended, as they comply with the criteria in TMC 18.52.100.B and F. The applicant will
need to:
o Prior to building permit approval, provide a certified arborist's assessment of the
valuation of each tree to be retained; and
o Prior to building permit approval, post a financial assurance based on 50% of that
valuation to ensure tree replacement should they be damaged or die as a result of
construction impacts; and
o Post the valuation of the tree to be retained on the tree prior to site preparation and retain
the posting throughout the construction of the project.
All of the required plantings are shown to be served by a permanent irrigation system, except for the
proposed parking lot landscape island. A permanent irrigation system for the plantings in this island
will need to be provided.
Street trees are required to be located on the back of curb face, however a modification is requested to
place some of the required street trees at the back of sidewalk. This modification is recommended, as
it helps create an enhanced pedestrian plaza area with planter boxes, benches, and a pergola. The
proposal exceeds the minimum number of trees that would otherwise be provided through strict
adherence to this standard.
The site provides an enhanced public connection from Andover Park East to the Green River. A
recommended condition of approval has been included in this staff report that the applicant provide
signage which indicates the public nature of this connection.
IV. Southcenter Design Manual
A. Site Design Elements
23
The proposed site layout, landscaping, open space, and other design elements create a cohesive
design that meets the intent of the Design manual, which is "to encourage site design which is
easily understood, appropriate to the area, takes advantage of unique opportunities, and is a
positive element in the architectural character of the District within which it is located."
Services areas are either enclosed or screened from view. Vehicular circulation and surface
parking is located in the side and rear of the building; creating an attractive pedestrian -oriented
frontage along Andover Park E. A porte couchere is added for drop-offs by the main entrance. A
pedestrian path through the site connects Andover Park E. with the Green River Trail, and includes
design cues to avoid conflict with vehicular circulation.
The site lighting includes pedestrian -scale poles designed to promote safety. Along exterior
facades, lighting accentuates entry canopies and ground level facades. Various up -lights and
bollard lighting improve the appearance of landscaping and pedestrian areas.
The landscaping concept on the site provides screening but also acts as a unifying feature between
the site and the natural environment to the East. Public open space is provided in landscaped areas
along the site perimeter, and is enhanced through pedestrian -scale lighting, stamped concrete, and
benches. Much of the open space on the site is for common use by residents, within a 5th floor
deck and internal level-2 courtyard area, which includes areas for relaxation and gatherings.
B. Building Design
The proposed building achieves a more modern design than many of the buildings located along
Andover Park E., and provides architectural design and scale that is compatible with newly
redeveloped properties in the area.
Building details and elements, materials and colors, and window treatments used in the project
meet the design criteria. The renderings show an architectural concept that achieves variety in
form and materials that provide visual appeal, as well as design details that highlight important
design elements on the building and the site. At the base level, an attractive brick material is used
to anchor the building, along with prominent entrances and ground -floor windows. The overall
building facade includes ample vertical and horizontal modulation, and a change in materials or
features that indicate a "base" and "top". Building details such as high quality materials,
decorative kick -plate, and sconce lighting are present. At the request of the city, landscaped
trellises and window patterning was added to the north facade to screen a large expanse of blank
wall.
Overall, the proposal demonstrates an architectural theme that provides character and
compatibility with surrounding buildings in the TUC-TOD district, while meeting the functional
requirements of an assisted living facility.
RECOMMENDATIONS
Staff recommends approval of the Design Review application, including the proposed landscape
modifications meeting the criteria set forth in TMC 18.52.100, with the following conditions:
1. Prior to building permit approval:
a. A certified arborist shall determine the value of the three Leyland cypress trees to be
retained on -site.
24
b. A financial assurance will be posted based on 50% of the value of the retained trees to
ensure tree replacement should the retained trees be damaged or die as a result of
construction impacts. The financial assurance shall be retained for three years.
2. The following shall be shown on revised plans submitted and reviewed administratively as
part of the building permit application submittal:
a. A note on the Landscape Plan stating that "The value of each of the three trees to be
retained on -site shall be posted on the trees prior to site preparation and retained
throughout the construction of the project."
b. Per TMC 18.28.240.B.4, a permanent irrigation system for the parking lot landscape
island shall be provided.
c. Signage shall be provided indicating the public nature of the walkway connecting
Andover Park East to the Green River. A detail of the required signage and posting
location shall be provided.
INFORMATIONAL
1. All monument or wall signage will require a separate sign permit and will be reviewed at
that time for compliance with the Tukwila sign code (Title 19).
2. Applicant shall ensure that the project meets Fire Department requirements regarding
hydrant spacing and turning radii, and these shall be reviewed as part of the building
permit review.
25