Loading...
HomeMy WebLinkAboutPermit D14-0089 - REGENCY LIGHTING - STORAGE RACKSREGENCY LIGHTING 4477 S 134 PL D14-0089 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov 2613200084 4477 S 134 PL BLDG B Project Name: REGENCY LIGHTING DEVELOPMENT PERMIT Permit Number: D14-0089 Issue Date: 4/8/2014 Permit Expires On: 10/5/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: NORTH STREAM DEVELOPMENT 720 4TH AVE STE 102 , KIRKLAND, WA, 98033 JACK SLABODEN 101 23 AVE , MILTON, WA, 98345 PACIFIC CONSTRUCTION MILTON IN PO BOX 1139 , MILTON, WA, 98354 License No: PACIFCM012RH Lender: Name: Address: Phone: (206) 595-6921 Phone: (206) 870-1176 Expiration Date: 11/17/2015 DESCRIPTION OF WORK: STORAGE RACK INSTALLATION Project Valuation: $18,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Fees Collected: $757.78 Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: 125 Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Volumes: Cut: 0 Fill: 0 Number: 0 Water Meter: No Permit Center Authorized Signature: Date: L` `9"1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: J Date: "\—g— \ Print Name: —Serf. css-'oes This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. .. r 16: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 12: The total number of fire extinguishers required for an extra hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (4A 40 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 8: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be Tess than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 9: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 10: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 11: Maintain fire extinguisher coverage throughout. 15: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 17: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 18: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one -hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 20: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 13: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances#2327 and #2328) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 4046 SI-EPDXY/EXP CONC CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: -o �(4 � 'Q1It1 or o j:ce use on! CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 4477 South 134th Place Tenant Name: Regency Lighting PROPERTY OWNER Name: Northstream Properties Address: 720 4th Avenue #102 City: Kirkland State: WA zip: 98033 CONTACT PERSON — person receiving all project communication Name: John Martinez Address: 1800 East McFadden Ave #200A City: Sana Ana state: Ca Zip: 92705 Phone: (714) 269-8693 Fax: (877) 269-8657 Email: john@warehousepermits.com GENERAL CONTRACTOR INFORMATION Company Name: Pacific Construction Address: 101 23rd Avenue City: Milton State: Wa Zip: 98354 Phone: (206) 595-6921 Fax: (206) 926-1904 Contr Reg No.: PacificM012RH Exp Date: Tukwila Business License No.: 0995301 Ji4 Q�N lte 6 Ggzl King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: 0 Yes ❑ ..No )-(¢I32ro-or�j ARCHII ECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Structural Concepts Engineering Engineer Name: Ali Abolhassani Address: 1200 North Jefferson Street Unit F City: Anaheim State: Ca Zip: 93065 Phone: (714) 632-7730 Fax: (714) 632-7763 Email: mail@sceinc.net LENDER/BOND ISSUED (required for projects $5,000 or greater per ROW 19.27.095) Name: Address: City: State: Zip: H:Wpplications\Forms-Applications On Lme\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 18,000 Describe the scope of work (please provide detailed information): Storage Rack Installation Will there be new rack storage? Yes Existing Building Valuation: $ ❑.. No If yes, a separate permit and plan submittal will be required. vide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 14 Floor 241 Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes J No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinlders 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applcations\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING t 'r ER OR A ". ' ; AGENT Signature: Print Na Mailing Addr ss: 1800 East McFadden Ave #200A Date: - (- I Day Telephone: (714) 269-8693 Santa Ana Ca 92705 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID .78 D14 0088 Address: 4477 S 134 PL BLDG B Apn: 2613200084 $757.78 DEVELOPMENT $735.62 PERMIT FEE PLAN CHECK FEE WASHINGTON STATE SURCHARGE R000.322.100.00.00 R000.345.830.00.00 B640.237.114 $443.10 $288.02 $4.50 TECHNOLOGY FEE $22.16 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1536 R000.322.900.04.00 $22.16 $757.78 Date Paid: Thursday, March 20, 2014 Paid By: PACIFIC CONSTRUCTION Pay Method: CHECK 27738 Printed: Thursday, March 20, 2014 8:18 AM 1 of 1 II'ISYSTEMS INSPECTION RECORD Retain a copy with permit P CT • N.. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100,:Tukwila. WA 98188 (206) 431-3670' Permit Inspection Request Line (206) 431-2451 614 4061 Pr t: 2Cv 4- 'Type of Inspection: r6 J i to . (i, r. 4t _ �-`. G '` ` i Address-' -0'77 . 3 -I' 1.-'13t... Date Called: Special Instructions: Date Wanted:—'7 I 1 y Requester:am►, T Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: �1ernt��MptQ'rQ Date 1 Q REINSPECTION FEE WRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. e 0 F' va INSPECt'10N INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 .; Permit Inspection Request Line (206) 431-2451 Prof l eare Address: 1411/ f31 PL.5instruction ps ; i f 4 c9 ' �.. i `t "� �%'L• . Phone No: ocs_ Tvoe inspection: Aco Requester: roved per applicable codes. Corrections required prior to approval. COMMENTS: 0). 'H: ewe. MAX (ApAer P� 7 (t'" Acir L� /JAL.< 6.4 Date1 14 REINSPECTION FEE RE + ' ED. Prior to next inspection, fee must be. paid at 6300 Southcenter bid., Suite 100. Call to schedule reinspection INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Pr9ject: t ek Typ f I spection: Address: Suite #: yy77 ! S J3Ll 12. h� Contact Pe n: Special Instructions: Phone No.: ' Approved per applicable codes. COMMENTS: PA-aes - nCorrections required prior to approval Needs Shift Inspection: ? Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector6(.1SC-- Date: 9�1//// %r Hrs.: n $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing Piling S t e e I Soils Wood r April 10, 2014 File No. 14-190 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit: Regency Lighting 4477 S. 134th Place D14 0089 A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND MATERIAL TESTING NATIONALLY ACCEPTED LABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. A4A4At44 Kimberle Anderson President CC: Pacific Construction -Jay Farber Regency Lighting -Joe Daley Tel: (425) 881-5812 Fax (425) 881-5441 • 7126 180th Ave. NE • P.O. Box 2523 • Redmond, WA 98073 Field Report Report #: 058933 Client: Pacific Construction P.O. Box 1139 Milton, WA 98354 Contact: Jay Farber Project Number: Permit #: Project Name: Address: 14190 D14-0089 Regency Lighting 4477 S. 134th Place Inspection Performed: Proprietary Anchors Date: 2/26/2014 Time: Temperature: Anchor bolts for pallet racks per drawing Al. Verified installation of Powers SD wedge anchors 1/2 x 4 1/2 with 3 1/4" embed torqued to 50 ft./lbs. All placed per plan. Distribution: t i Distribute Client ❑ Distribute Engineer Distribute Municipality ri Distribute Architect ❑ Distribute Contractor ❑ Distribute Owner ❑ Distribute Other i—I Distribute Other Inspector: Trow, Michael Reviewed by: Michele Guerrini All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden St ctural nceptsngine 1200 N. Jefferson St, Suite F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 e-mail: mail@sceinc.net Project Name : REGENCY LIGHTING Project Number : 0-022114-5 Date : Street Address : City/State : Scope of Work : 02/20/14 4477 SOUTH 134TH PLAGE TUKWILLA, WA 98108 SELECTIVE RACK li5OL EXPIRE • trielop REVIEWED FOR CODE COMPLIANCE APPROVED APR 04 2014 City of Tukwila ING DIVISION 0 Z. TONAL RECEIVED CITY OF TUKWILA MAR 2 0 2014 PERMIT CENTER Str tural oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA_92807 Tel: 714132.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 TABLE OF CONTENTS Title Page 1 Table of Contents 2 Design Data and Definition of Components 3 Critical Configuration 4 Seismic Loads 5 to 6 Column 7 Beam and Connector 8 to 9 Bracing 10 Anchors 11 Base Plate 12 Slab on Grade 13 Other Configurations 14 to 15 TYPE 1 SELECT-REGENCY.xis Page 2 of 2/26/2014 Strturai oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA92607 Tel:714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Design Data Project #: 0-022114-5 1) The analyses herein conforms to the requirements of the: 2012 IBC Section 2209 2013 CBC Section 2209A ANSI MH 16.1-2012 Specifications for the Design of Industrial Steel Storage Racks "2012 RMI Rack Design Manual" ASCE7-10, section 15.5.3 2) Transverse braced frame steel conforms to ASTM A570, Gr.55, with minimum strength, Fy=55 ksi Longitudinal frame beam and connector steel conforms to ASTM A570, Gr.55, with minimum yield, Fy=55 ksi All other steel conforms to ASTM A36, Gr. 36 with minimum yield, Fy= 36 ksi 3) Anchor bolts shall be provided by installer per ICC reference on plans and calculations herein. 4) All welds shall conform to AWS procedures, utilizing E70xx electrodes or similar. All such welds shall be performed in shop, with no field welding allowed other than those supervised by a licensed deputy inspector. 5) The existing slab on grade is 5" thick with minimum 2500 psi compressive strength. Allowable Soil bearing capacity is 1000 psf. The design of the existing slab is by others. 6) Load combinations for rack components correspond to 2012 RMI Section 2.1 for ASD level Toad criteria Definition of Components Frame Height A Beam 1 Beam Length Beam Spadng Front View: Down Aisle (Longitudinal) Frame Column Beam to Column Connector Base Plate and Anchors Panel Height Frame Death Section A: Cross Aisle (Transverse) Frame Horizontal Brace Diagonal Brace TYPE I SELECT-REGENCY.xis Page 3 of 2/26/20 14 Strtural concepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 1 x 7 4.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Configuration & Summary: TYPE 1 SELECTIVE RACK 216" 44" 4- 58" 96" 24" 74" 216 f 52" 52" 42" --I- 42" **RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 200 /b AXIAL LL= 3,000 /b SEISMIC AXIAL Ps=+/- 3,074 /b BASE MOMENT= 8,000 in lb Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.494, Fa=1 4 42 in 216.0 in 4 96 in Single Row Component Description STRESS Column Fy=55 ksi INTLK LU72/3x3x14ga P=3200 Ib, M=14688 in-Ib 0.57-0K Column & Backer None None None N/A Beam Fy=55 ksi Intlk 282/3.04"deepx2"x0.07" Lu=96 in Capacity: 2496 Ib/pr 0.6-0K Beam Connector Fy=55 ksi Lvl 1: 2 pin OK I Mconn=8997 in-Ib Mcap=9726 in-Ib 0.93-0K Brace -Horizontal Fy=55 ksi Intlk 1-1/2x1-1/2x14ga 0.13-0K Brace -Diagonal Fy=55 ksi Intik 1-1/2x1-1/2x14ga 0.24-OK Base Plate Fy=36 ksi 8x5x3/8 I Fixity= 8000 in-Ib 0.63-0K Anchor 2 per Base 0.5" x 3.25" Embed POWERS SD2 ESR 2502 Inspection Reqd (Net Seismic Uplift=2056 Ib) 0.808-OK Slab & Soil 5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure 0.4-0K Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 1,500 Ib 58.0 in 52.0 in 129 Ib 97 Ib 3,200 Ib 14,688 "# 8,997 "# 2 pin OK 2 1,500 Ib 3 1,500 Ib 4 1,500 Ib 44.0 in 44.0 in 44.0 in 52.0 in 74.0 in 24.0 in 226 Ib 324 Ib 422 Ib 170 Ib 243 Ib 316 Ib 2,400 Ib 1,600 Ib 800 Ib 8,014 "# 6,147 "# 3,476 "# 6,008 "# 4,420 "# 2,269 "# 2 pin OK 2 pin OK 2 pin OK ** Load defined as product weight per pair of beams Notes Total: 1,101 Ib 825 Ib TYPE I SELECT-REGENCY.xIs Page "of / J 2/2G/2014 Sttural rIsoncepts .,,„.1/41r/ -f-,7• Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Seismic Forces Configuration: TYPE 1 SELECTIVE RACK Lateral analysis is performed with regard to the requirements of the 2012 RMI ANSI MN 16.1-2012 Sec 2.6 & ASCE 7-10 sec 15.5.3 Transverse (Cross Aisle) Seismic Load V= Cs*Ip*Ws=Cs*Ip*(0. Cs1= Sds/R = 0.2490 Cs2= 0.044*Sds = 0.0438 Cs3= 0.5*S1/R = 0.0700 Cs -max= 0.2490 Base Shear Coeff=Cs= 0.2490 67*P*Prf+D) Cs -max * Ip= 0.2490 Vmin= 0.015 Eff Base Shear=Cs= 0.2490 Transverse Elevation Ws= (0.67*PLRF1 * PL)+DL (RMI 2.6.2) = 4,420 Ib vt Level PRODUCT LOAD P P*0.67*Pal 1 1,500 Ib 1,005 Ib 2 1,500 Ib 1,005 Ib 3 1,500 Ib 1,005 Ib 4 1,500 Ib 1,005 Ib Vtransv=Vt= 0.249 * (400 Ib + 4020 Ib) Etransverse= 1,101 Ib limit Stales Levert Transverse seismic shear per upright DL 100 Ib 100 Ib 100 Ib 100 Ib hi 58 in 102 in 146 in 190 in wi*hi 64,090 112,710 161,330 209,950 Ss= 1.494 S1= 0.560 Fa= 1.000 Fv= 1.500 Sds=2/3*Ss*Fa= 0.996 Sd1=2/3*S1*Fv= 0.560 Ca=0.4*2/3*Ss*Fa= 0.3984 (Transverse, Braced Frame Dir.) R= 4.0 Ip= 1.0 PRF1= 1.0 Pallet Height=hp= 48.0 in DL per Beam Lvl= 100 lb Fi Fi*(hi+hp/2) 128.7 Ib 10,553-# 226.4 Ib 28,526-# 324.1 Ib 55,097-# 421.8 Ib 90,265-# sum: P=6000 Ib 4,020 Ib Longitudinal (Downaisle) Seismic Load 400 Ib W=4420 Ib 548,080 1,101 lb 1=184,442 Similarly for longitudinal seismic loads, using R=6.0 Cs1=Sd1/(T*R)= 0.1867 Cs2= 0.0438 Cs3= 0.0467 Cs -max= 0.1867 Level 1 2 3 4 PRODUC LOAD P 1,500 Ib 1,500 Ib 1,500 Ib 1,500 Ib Ws= (0.67 * PLC * = 4,420 Ib Cs=Cs-max*Ip= 0.1867 P) + DL PRF2= 1.0 (Longitudinal, Unbraced Dir.) R= 6.0 T= 0.50 sec Vlong= Elongitudlnal= 0.1867 * (400 Ib + 4020 Ib) 825 Ib Limit States Lend Longh: sehmkshear per upright P*0.67*P 1,005 Ib 1,005 Ib 1,005 Ib 1,005 Ib DL 100 Ib 100 Ib 100 Ib 100 Ib hi 58 in 102 in 146 in 190 in wi*hi 64,090 112,710 161,330 209,950 F 96.5 Ib 169.7 Ib 242.8 Ib 316.0 Ib Front View 1 sum: 4,020 lb 400 Ib W=4420 Ib 548,080 825 Ib TYPE I SELECT-REGENCY.xls Page 5 of 2/26/20 14 Str tural oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Downaisle Seismic Loads Configuration: TYPE 1 SELECTIVE RACK Determine the story moments by applying portal analysis. The base plate is assumed to provide partial fixity. Seismic Story Forces Vlong= 825 Ib Vcol=Vlong/2= 413 Ib F1= 97 Ib F2= 170 Ib F3= 243 Ib Seismic Story Moments - - Typical frame made Tributary area oftwocolumns of rock frame \- 4— Front View Conceptual System Side View Typical Frame made _ of two columns 41 Top View Mbase-max= 8,000 in-Ib <=== Default capacity Mbase-v= (Vcol*hleff)/2 = 11,344 in-Ib <=== Moment going to base Mbase-eff= Minimum of Mbase-max and Mbase-v = 8,000 in-Ib M 1-1= [Vcol * hleff]-Mbase-eff = (413 Ib * 55 in)-8000 in-Ib = 14,688 in-Ib Mseis= (Mupper+Mlower)/2 hl-eff= hl - beam dip height/2 = 55 in Vcol M 2-2= [Vcol-(F1)/2] * h2 [413 Ib - 84.9 Ib]*44 in/2 = 8,014 in-Ib Mseis(1-1)= (14688 in-Ib + 8014 in-Ib)/2 Mseis(2-2)= (8014 in-Ib + 6147 in-lb)/2 = 11,351 in-Ib = 7,080 in-Ib Beam to Column Elevation rho= 1.0000 COL Summary of Forces LEVEL 1 2 3 4 hi Axial Load 58 in 3,200 Ib 44 in 2,400 Ib 44 in 1,600 Ib 44 in 800 Ib Column Moment** 14,688 in-Ib 8,014 in-Ib 6,147 in-Ib 3,476 in-Ib Mseismic** 11,351 in-Ib 7,080 in-Ib 4,811 in-Ib 1,738 in-Ib Mend -fixity 1,503 in-Ib 1,503 in-Ib 1,503 in-Ib 1,503 in-Ib Mconn** 8,997 in-Ib 6,008 in-Ib 4,420 in-Ib 2,269 in-Ib Beam Connector 2 pin OK 2 pin OK 2 pin OK 2 pin OK Mconn= (Mseismic + Mend-fixity)*0.70*rho Mconn-allow(2 Pin)= 9,726 in-Ib **all moments based on limit states level loading TYPE I SELECT-REGENCY.xIs Page 4,9 of 2/26/20 14 Str tural L oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tell714.632.7330 Fax:_714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Column (Longitudinal Loads) Configuration: TYPE 1 SELECTIVE RACK Section Properties Section: INTLK LU72/3x3x14ga Aeff = 0.643 inA2 Ix = 1.130 in^4 Sx = 0.753 in^3 rx = 1.326 in Of= 1.67 E= 29,500 ksi Loads Considers loads at level 1 Iy = 0.749 in^4 Sy = 0.493 in^3 ry = 1.080 in Fy= 55 ksi Cmx= 0.85 Kx = 1.7 Lx = 56.5 in Ky = 1.0 Ly = 52.0 in Cb= 1.0 3.000 in x II i I 1 _ 1o.o75 in x 1.0.75 in 3.000 in COLUMN DL= 200 Ib COLUMN PL= 3,000 Ib Mcol= 14,687 in-Ib Sds= 0.9960 1+0.105*Sds= 1.1046 1.4+0.14Sds= 1.5394 1+0.14Sds= 1.1394 0.85+0.14*Sds= 0.9894 B= 0.7000 rho= 1.0000 Axial Analysis C itical load cases are: RMI Sec 2.1 Load Case 5: : (1 +0.105*Sds)D + 0.75*(1.4+0.14Sds)*B*P + 0.75*(0.7*rho*E)<=1.0, ASD Method axial load coeff.• 0.808206 * P seismic moment coef• 0.5625 * Mcol Load Case 6: : (1+0.104*Sds)D + (0.85+0.14Sds)*B*P + (0.7*rbo*E)<= 1.0, ASD Method axial load coef 0.69261 seismic moment coeff.• 0.7 * Mcol By analysis, Load case 6 govems utilizing loads as such Axial Load=Pax= 1.13944*200 Ib + 0.98944*0.7*3000 Ib = 2,3061b Moment=Mx= 0.7*rho*Mcol = 0.7 * 14687 in-Ib = 10,281 in -lb KxLx/rx = 1.7*56.48"/1.326" KyLy/ry = 1*5271.08" = 72.4 = 48.1 Fe= n^2E/(KI./r)max^2 = 55.5ksi Pn= Aeff*Fn = 26,608 Ib P/Pa= 0.17 > 0.15 Bending Analysis Fy/2= 27.5 ksi Qc= 1.92 Fe > Fy/2 Fn= Fy(1-Fy/4Fe) = 55 ksi*[1-55 ksi/(4*55.5 ksi)] = 41.4 ksi Pa= Pn/Qc = 26608 Ib/1.92 = 13,858 Ib Check: Pax/Pa + (Cmx*Mx)/(Max*px) <_ 1.0 P/Pao + Mx/Max 5 1.0 Pno= Ae*Fy = 0.643 in^2 *55000 psi = 35,365 Ib Max= My/Qf = 41415 in-Ib/1.67 = 24,799 in-Ib I x= {1/[1-(Qc*P/Pcr)]}^-1 = {1/[1-(1.92*2306 Ib/35687 lb)]}^-1 = 0.88 Combined Stresses Pao= Pno/Qc = 353651b/1.92 = 18,419 Ib Myield=My= Sx*Fy = 0.753 in^3 * 55000 psi = 41,415 in-Ib Pcr= n^2EI/(KL)max^2 = nA2*29500 ksi/(1.7*56.48 in)^2 = 35,687 Ib (2306 lb/13858 Ib) + (0.85*10281 in-lb)/(24799 in-Ib*0.88) = (2306 Ib/18419 lb) + (10281 in-lb/24799 in-Ib) = 0.57 < 1.0, OK (EQ C5-1) 0.54 < 1.0, OK (EQ C5-2) ** For comparison, total column sb ess computed for load case 5 is: 50.0% //zing loads 2645.534 /b Axial and M= 7710 in -lb TYPE I SELECT-REGENCY.xis Page of l� 2/26/20 14 Str tural on is ire ; ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 BEAM Configuration: TYPE 1 SELECTIVE RACK DETERMINE ALLOWABLE MOMENT CAPACITY A) Check compression flange for local buckling (B2.1) w= c - 2*t -2*r = 1.75 in - 2*0.07 in - 2*0.07 in = 1.470 in w/t= 21 1=lambda= [1.052/(k)A0.5] * (w/t) * (Fy/E)^0.5 = [1.052/(4)A0.5] * 21 * (55/29500)^0.5 = 0.477 < 0.673, Flange is fully effective Eq. B2.1-4 Eq. B2.1-1 B) check web for local buckling per section b2.3 fl(comp)= Fy*(y3/y2)= 47.55 ksi f2(tension)= Fy*(y1/y2)= 99.32 ksi Y= f2/f1 Eq. B2.3-5 = -2.089 k= 4 + 2*(1-Y)^3 + 2*(1-Y) Eq. B2.3-4 = 69.13 flat depth=w= y1+y3 = 2.760 in w/t= 39.42857143 OK 1=lambda= [1.052/(k)^0.5] * (w/t) * (fl/E)^0.5 = [1.052/(69.13)1\0.5] * 2.76 * (47.55/29500)A0.5 = 0.2 < 0.673 be=w= 2.760 in b2= be/2 Eq 82.3-2 b1= be(3-Y) = 1.38 in = 0.542 b1+b2= 1.922 in > 0.8936 in, Web is fully effective Determine effect of cold working on steel yield point (Fya) per section A7.2 Fya= C*Fyc + (1 C)*Fy (EQ A7.2-1) Lcomer=lc= (p/2) * (r + t/2) 0.165 in C= 2*Lc/(Lf+2*Lc) Lflange-top=Lf= 1.470 in = 0.183 in m= 0.192*(Fu/Fy) - 0.068 (EQ A7.2-4) = 0.1590 Bc= 3.69*(Fu/Fy) - 0.819*(Fu/Fy)^2 - 1.79 (EQ A7.2-3) = 1.427 since fu/Fv= 1.18 < 1.2 and r/t= 1 < 7 OK then Fyc= Bc * Fy/(R/t)^m (EQ A7.2-2) = 78.485 ksi Thus, Fya-top= 59.31 ksi (tension stress at top) Fya-bottom= Fya*Ycg/(depth -Ycg) = 115.12 ksi (tension stress at bottom) Check allowable tension stress for bottom flange Lflange-bot=Lfb= Lbottom - 2*r*-2*t = 1.720 in Cbottom=Cb= 2*Lc/(Lfb+2*Lc) = 0.161 Fy-bottom=Fyb= Cb*Fyc + (1-Cb)*Fyf = 58.78 ksi Fya= (Fya-top)*(Fyb/Fya-bottom) = 30.28 ksi if F= 0.95 Then F*Mn=F*Fya*Sx= 2.00 in 1.75 In 3.040 in Beam= Intik 282/3.04"deeux2"x0.07" Ix= Sx= Ycg= t= Bend Radius=r= Fy=Fyv= Fu=Fuv= E= top flange=b= bottom flange= Web depth= DIAFY' t -� n y3 depth 1 12.48 in-k Ycg 11 0.731 in^4 0.434 in^3 2.006 in 0.070 in 0.070 in 55.00 ksi 65.00 ksi 29500 ksi 1.750 in 2.000 in fl (comp) f2(tension) y1= Ycg-t-r= 1.866 in y2= depth-Ycg= 1.034 in y3= y2-t-r= 0.894 in Str tural on is ngineering 1200 N. Jefferson Ste, Ste F Anaheim, CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 BEAM Contiguration: TYPE 1 SELECTIVE RACK RMI Section 5.2, PT II Section Beam= Intik 282/3.04"deepx2"x0.07" Ix=Ib= 0.731 in^4 Sx= 0.434 in^3 t= 0.070 in Fy=Fyv= 55 ksi Fu=Fuv= 65 ksi Fya= 59.3 ksi E= 29500 ksi F= 150.0 L= 96 in Beam Level= 1 P=Product Load= 1,500 lb/pair D=Dead Load= 100 Ib/pair 1. Check Bending Stress Allowable Loads Mcenter=F*Mn= W*L*W*Rm/8 W=LRFD Load Factor= 1.2*D + 1.4*P+1.4*(0.125)*P FOR DL=2% of PL, RMI2.2, item 8 W= 1.599 Rm= if F= Then F*Mn=F*Fya*Sx= Thus, allowable load per beam pair=W= 1 - [(2*F*L)/(6*E*Ib + 3*F*L)] 1- (2*150*96 in)/[(6*29500 ksi*0.731 in^3)+(3*150*96 in)] 0.833 0.95 24.43 in-k F*Mn*8*(# of beams)/(L*Rm*W) 24.43 in-k * 8 * 2/(96in * 0.833 * 1.599) 3,057 Ib/pair allowable load based on bending stress Mend= W*L*(1-Rm)/8 = (3057 lb/2) * 96 in * (1-0.833)/8 = 3,063 in-Ib @ 3057 Ib max allowable load = 1,503 in-Ib @ 1500 Ib imposed product load 2. Check Deflection Stress Allowable Loads 200 in 1.75 in 3.040 in 111111111111111111111111111111111111111111111 Dmax= Dss*Rd Rd= 1 - (4*F*L)/(5*F*L + 10*E*Ib) = 1 - (4*150*96 in)/[(5*150*96 in)+(10*29500 ksi*0.731 in^4)] = 0.800 in if Dmax= 1/180 Based on L/180 Deflection Criteria and Dss= 5*W*L^3/(384*E*Ib) L/180= 5*W*L^3*Rd/(384*E*Ib*# of beams) solving for W yields, W= 384*E*I*2/(180*5*L^2*Rd) = 384*0.731 in^4*2/[180*5*(96 in)^2*0.8) = 2,496 Ib/pair allowable load based on deflection limits Thus, based on the least capacity of item 1 and 2 above: Allowable Deflection= L/180 = 0.533 in Deflection at imposed Load= 0.321 in Allowable load= 2,496 Ib/pair Imposed Product Load= 1,500 Ib/pair Beam Stress= 0.6 Beam at Level 1 ngineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-0221 14-5 2 Pin Beam to Column Connection TYPE 1 SELECTIVE RACK I he beam end moments shown herein show the result ot the maximum Induced tlxed end monents torm seismic + static loads and the code mandated minimum value ot 1.5%(DL+PL) Mconn max= (Mseismic + Mend-fixity)*0.70*Rho = 8,997 in-Ib Load at level 1 Connector Type= 2 Pin Shear Capacity of Pin 0 P1 P2 4" 1/2"�C 12" rho= 1.0000 Pin Diam= 0.44 in Fy= 55,000 psi Ashear= (0.438 in)^2 * Pi/4 = 0.1507 in^2 Pshear= 0.4 * Fy * Ashear = 0.4 * 55000 psi * 0.1507in^2 = 3,315 Ib Bearing Capacity of Pin tcol= 0.075 in Fu= 65,000 psi Omega= 2.22 a= 2.22 Pbeanng= alpha * Fu * diam * tcol/Omega = 2.22 * 65000 psi * 0.438 in * 0.075 in/2.22 = 2,135 lb < 3315 Ib Moment Capacity of Bracket Edge Distance=E= 1.00 in C= P1+P2 = P1+P1*(0.5 /4.5") = 1.11 * P1 Pin Spacing= 4.0 in Fy= 55,000 psi Mcap= Sclip * Fbending =0.127in^3*0.66*Fy = 4,610 in-Ib Pclip= Mcap/(1.11 * d) = 4610.1 in-lb/(1.11 * 0.5 in) = 8,306 Ib tdip= 0.18 in Sclip= 0.127 in^3 Mconn-allow= [P1*4.5'+P1*(0.574.5")*0.59 = 2135 LB*[4.5"+(0.5"/4.5")*0.51 = 9,726 in-Ib > Mconn max, OK C*d= Mcap = 1.11 Thus, P1= 2,135 Ib d= E/2 = 0.50 in TYPE 1 SELECT-REGENCY.xle Page 'of /f 2/26/2014 Strturai oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 TeL 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Transverse Brace Configuration: TYPE 1 SELECTIVE RACK Section Properties Diagonal Member= Intik 1-1/2x1-1/2x14ga Area= 0.315 inA2 r min= 0.488 in Fy= 55,000 psi K= 1.0 Qc= 1.92 Frame Dimensions I .500 1 -0.25 Horizontal Member= Intik 1-1/2x1-1/2x14ga Area= 0.315 in^2 r min= 0.488 in Fy= 55,000 psi 1.500 K= 1.0 10- I .500 --o-I -01 0.25 I.500 Wst L( Bottom Panel Height=H= 52.0 in Frame Depth=D= 42.0 in Column Width=B= 3.0 in Diagonal Member Clear Depth=D-B*2= 36.0 in X Brace= NO rho= 1.00 0 Load Case 6: : (1 +o J4aa i 85+0.l45ds)*B*P + [0.7*rho*EJ<= 1.0, ASD Method Vtransverse= 1,101 Ib Vb=Vtransv*0.7*rho= 1101 Ib * 0.7 * 1 = 7711b Ldiag= [(D-B*2)^2 + (H-6")^2]^1/2 = 58.4 in Pmax= V*(Ldiag/D) * 0.75 = 8041b axial load on diagonal brace member Pn= AREA*Fn = 0.315 in^2 * 20320 psi = 6,401 Ib Pallow= Pn/Q = 6401 Ib /1.92 = 3,334 Ib Pn/Pallow= 0.24 <= 1.0 OK Horizontal brace (kl/r)= (k * Ldiag)/r min = (1 x 58.4 in /0.488 in ) = 119.7 in Fe= pi^2*E/(kl/r)A2 = 20,320 psi Since Fe<Fy/2, Fn= Fe = 20,320 psi Check End Weld Lweld= 2.5 in Fu= 65 ksi tmin= 0.075 in Weld Capadty= 0.75 * tmin * L * Fu/2.5 = 3,656 Ib OK Vb=Vtransv*0.7*rho= 771 Ib (kl/r)= (k * Lhoriz)/r min = (1 x 42 in) /0.488 in = 86.1 in Since Fe>Fy/2, Fn=Fy*(1-fy/4fe) = 35,745 psi Pn/Pallow= 0.13 <= 1.0 OK Fe= pi^2*E/(kl/r)^2 = 39,275 psi Pn= AREA*Fn = 0.315in^2*35745 psi = 11,2601b Fy/2= 27,500 psi Pallow= Pn/Qc = 11260 Ib /1.92 = 5,864 Ib TYPE I SELECT-REGENCY.xIs Page/ D of !' 1 2/26/20 14 Str urat Ltoncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Single Row Frame Overturning Configuration: TYPE 1 SELECTIVE RACK Loads Critical Load case(s): 1) RMI Sec 2.1, item 9: (0.6-0.14Sds)D + (0.6-0.14Sds)*B*Papp - 0.7*E*rho Vtrans=V=E=Qe= 1,101 Ib DEAD LOAD PER UPRIGHT=D= 400 lb PRODUCT LOAD PER UPRIGHT=P= 6,000 Ib Papp=P*0.67= 4,020 Ib 21=Wst1=(0.46056*D + 0.46056*Papp*1)= 2,035 Ib Product Load Top Level, Ptop= 1,500 Ib DL/LvI= 100 Ib Seismic Ovt based on E, E(Fi*hi)= 184,442 in-Ib heiaht/depth ratio= 4.5 in Sds= 0.9960 (0.6-0.14Sds)= 0.4606 (0.9-0.2Sds)= 0.7008 B= 1.0000 rho= 1.0000 Frame Depth=Df= 42.0 in Htop-Iv1=H= 190.0 in # Levels= 4 # Anchors/Base= 2 hp= 48.0 in SIDE ELEVATION A) Fully Loaded Rack h=H+hp/2= 214.0 in Load case 1: Movt= E(Fi*hi)*0.7*E*rho Mst= Wstl * Df/2 = 129,109 in-Ib = 2035 Ib * 42 in/2 = 42,735 in-Ib T= (Movt-Mst)/Df = (129109 in-Ib - 42735 in-Ib)/42 in = 2,057 Ib Net Uplift per Column Net Seismic Uplift= 2,057 Ib B) Top Level Loaded Only Load case 1: 0 V1=Vtop= Cs * Ip * Ptop >= 350 Ib for H/D >6.0 = 0.249 * 1500 Ib = 374 Ib Vleff= 374 Ib Critical Level= 4 V2=VDL= Cs*Ip*D Cs*Ip= 0.2490 = 100 Ib Mst= (0.46056*D + 0.46056*Ptop*1) * 42 in/2 = 18,376 in-Ib Movt= [V1*h + V2 * H/2]*0.7*rho = 62,574 in-Ib T= (Movt-Mst)/Df = (62574 in-Ib - 18376 in-lb)/42 in = 1,052 Ib Net Uplift per Column Net Seismic Uplift= 1,052 Ib Anchor Check (2) 0.5" x 3.25" Embed POWERS SD2 anchor(s) per base plate. Special inspection is required per ESR 2502. Pullout Capacity=Tcap= 1,250 Ib Shear Capacity=Vcap= 1,840 Ib Phi= 1 (1028 Ib/1250 Ib)^1 + (275 Ib/18401b)^1 = (526 ib/1250 Ib)^1 + (93 Ib/1840 Ib)^1 = Fully Loaded: Top Level Loaded: L.A. City Jurisdiction? NO Tcap*Phi= 1,250 Ib Vcap*Phi= 1,840 Ib 0.97 <= 1.2 OK 0.47 <= 1.2 OK TYPE I SELECT-REGENCY.xis Page /7 of 2/26/2O 14 Cross Aisle Loads $trturaI oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project#: 0-022114-5 Base Plate Configuration: TYPE 1 SELECTIVE RACK Section Baseplate= 8x5x3/8 Eff Width=W = 8.00 in a = 3.00 in Eff Depth=D = 5.00 in Anchor c.c. =2*a=d = 6.00 in Column Width=b = 3.00 in N=# Anchor/Base= 2 Column Depth=dc = 3.00 in Fy = 36,000 psi L = 2.50 in Plate Thickness=t = 0.375 in Down Aisle Loads Load Case 5: : (1 +0.105*Sds)D + 0.75*[(1.4+0.14Sds)*B*P + 0.75*[0.7*rho*Ek=1.0, ASD Method Downaisle Elevation COLUMN DL= 200 Ib Axial=P= 1.10458 * 200 Ib + 0.75 * (1.53944 * 0.7 * 3000 Ib) COLUMN PL= 3,000 Ib = 2,646 Ib Base Moment= 8,000 in-Ib 1+0.105*Sds= 1.1046 1.4+0.14Sds= 1.5394 B= 0.7000 Axial stress=fa = P/A = P/(D*W) = 66 psi Moment Stress=fb = M/S = 6*Mb/[(D*BA2] = 78.8 psi Moment Stress=fbl = fb-fb2 = 29.5 psi M3 = (1/2)*fb2*L*(2/3)*L = (1/3)*fb2*L^2 = 103 in-Ib S-plate = (1)(tA2)/6 = 0.023 in^3/iri fb/Fb = Mtotal/[(S-plate)(Fb)] 0.63 OK Tanchor = (Mb-(PLapp*0.75*0.46)(a))/[(d)*N/2] = -318 Ib No Tension Critical badarse RMISec 2.1, Item 4: (1+0.115dr)At + (1+0.14SOS)Pt'0.75+E2•0.75 <= 1.0, ASD Method Mb= Base Moment*0.75*0.7*rho = 8000 in-Ib * 0.75*0.7*rho = 4,200 in-Ib Axial Load P = 2,646 Ib Mbase=Mb = 4,200 in-Ib M1= Moment Stress=fb2 = M2= Mtotal = Fb = Pp= Tallow= wLA2/2= fa*L^2/2 207 in-Ib 2*Po*1/W 49.2 psi fb1*L^2)/2 92 in-Ib M1+M2+M3 402 in-Ib/in 0.75*Fy 27,000 psi 0.7*Pc 1,750 psi OK 1,250 Ib OK Check uplift Toad on Baseplate Effec. Effec. E Pstatic= 2,646 Ib Movt*0.75*0.7*rho= 96,832 in-Ib Frame Depth= 42.0 in P=Pstatic+Pseismic= 4,951 Ib b =Column Depth= 3.00 in L =Base Plate Depth -Col Depth= 2.50 in fa = P/A = P/(D*W) = 124 psi Sbase/in = (1)(t^2)/6 = 0.023 in^3/in fb/Fb = M/[(S-plate)(Fb)] = 0.61 OK Pseismic= Movt/Frame Depth = 2,306 Ib M= wL^2/2= fa*L^2/2 = 387 in-Ib/in Fbase = 0.75*Fy = 27,000 psi Check uplift forces on baseplate with 2 or more anchors per RMI 7.2.2. the base plate configuration consists of two anchor bolts bated an either side the column and a net uplift force exists, the minimum base plate thickness all be determined based on a design bending moment in the plate equal o the uplift force on one anchor times 1/2 the distance from e centerline of the anchor to the nearest edge of the rack column" Ta I4— c* Mu .gallll T I b I Uplift per Column= 2,056 Ib Qty Anchor per BP= 2 Net Tension per anchor=Ta= 1,028 Ib c= 2.50 in Mu=Moment on Baseplate due to uplift= Ta*c/2 = 1,285 in-Ib Splate= 0.117 in^3 fb Fb *0.75= 0.305 OK TYPE I SELECT-REGENCY.xIs Page / f 2/26/2O 14 $trturaI L,oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Slab on Grade Configuration: TYPE 1 SELECTIVE RACK IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIiiIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII SLAB ELEVATION Base Plate Effec. Baseplate width=B= 8.00 in Effec. Baseplate Depth=D= 5.00 in Column Loads width=a= 3.00 in depth=b= 3.00 in • [13 c e Cross Aisle Down Aisle FF .... . Baseolate Plan View Concrete Pc= 2,500 psi tslab=t= 5.0 in teff= 5.0 in phi=0= 0.6 Soil (soil= 1,000 psf Movt= 129,109 in-Ib Frame depth= 42.0 in Sds= 0.996 0.2*Sds= 0.199 midway dist face of column to edge of plate=c= 5.50 in midway dist face of column to edge of plate=e= 4.00 in DEAD LOAD=D= 200 Ib per column unfactored ASD /oad PRODUCT LOAD=P= 3,000 Ib per column unfactored ASD /oad Papp= 2,010 Ib per column P-seismic=E= (Movt/Frame depth) = 3,074 Ib per column unfactored Limit State /oad B= 0.7000 rho= 1.0000 Sds= 0.9960 1.2 + 0.2*Sds= 1.3992 0. 9 - 0.20Sds= 0.7008 Puncture Load Case 1) (1.2+0.2Sds)D + (1.2+0.2Sds)*B*P+ rho*E = 1.3992 * 200 Ib + 1.3992 * 0.7 * 3000 Ib + 1 = 6,292 Ib Load Case 2) (0.9-0.2Sds)D + (0.9-0.2Sds)*B*Papp + rho*E = 0.7008 * 200 Ib + 0.7008 * 0.7 * 2010 Ib + 1 * = 4,200 Ib Load Case 3) 1.2*D + 1.4*P = 1.2*200 Ib + 1.4*3000 Ib = 4,440 Ib Effective Column Load=Pu= 6,292 Ib per column RMISEC2.2EQTN5 3074 Ib RMI SEC 2.2 EQTN 7 3074 Ib RMI SEC 2.2 EQTN 1,2 Apunct= [(c+t)+(e+t)]*2*t = 195.0 in^2 Slab Bending Fpunct= 2.66*phi*sgrt(Pc) = 79.8 psi fv/Fv= Pu/(Apunct*Fpunct) = 0.404 < 1 OK Pse=DL+PL+E= 6,292 lb Asoil= (Pse*144)/(fsoil) = 906 in^2 x= (L-y)/2 = 7.7 in Fb= 5*(phi)*(Pc)^0.5 = 150. psi L= (Asoil)^0.5 = 30.10 in M= w*x^2/2 = (fsoil*x^2)/(144*2) = 206.1 in-Ib y= (c*e)^0.5 + 2*t = 14.7 in S-slab= 1*teff^2/6 = 4.17 in^3 fb/Fb= M/(S-slab*Fb) = 0.330 <1,OK TYPE I SELECT-REGENCY.xIs Page/3 of Li 2/26/20I4 Strpturai oncepts Engineering 1200 N. Jefferson Ste. Ste F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632_7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Configuration & Summary: TYPE 1A SELECTIVE RACK 44" —t- 216" 44" 4 58" 60" 24" 74" 216" -IF 52" f 52" 42" 4 +— 42" 4 **RACK COLUMN REACTIONS ASD LOADS AXIAL DL= 2001b AXIAL LL= 2,000lb SEISMICAXIAL Ps=+/- 2,141 lb BASE MOMENT= 8,000 in -lb Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.494, Fa=1 4 42 in 216.0 in 4 60 in Single Row Component Description STRESS Column Fy=55 ksi INTLK LU72/3x3x14ga P=2200 Ib, M=7907 in-Ib 0.31-0K Column & Backer None None None N/A Beam Fy=55 ksi Intik 485/4.04"deepx2.75"x0.07" Lu=60 in Capacity: 8485 Ib/pr 0.12-0K Beam Connector Fy=55 ksi Lvi 1: 2 pin OK I Mconn=4856 in-Ib Mcap=9726 in-Ib 0.5-0K Brace -Horizontal Fy=55 ksi Intik 1-1/2x1-1/2x14ga 0.09-OK Brace -Diagonal Fy=55 ksi Intik 1-1/2x1-1/2x14ga 0.17-OK Base Plate Fy=36 ksi 8x5x3/8 I Fixity= 7906 in-Ib 0.53-OK Anchor 2 per Base 0.5" x 3.25" Embed POWERS SD2 ESR 2502 Inspection Reqd (Net Seismic Uplift=1432 Ib) 0.567-OK Slab & Soil 5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure 0.28-0K Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 1,000 Ib 58.0 in 52.0 in 90 Ib 67 Ib 2,200 Ib 7,907 "# 4,856 "# 2 pin OK 3 1,000 Ib 4 1,000 Ib 44.0 in 44.0 in 44.0 in 52.0 in 74.0 in 24.0 in 158 Ib 226 Ib 294 Ib 118 Ib 169 Ib 220 Ib 1,650 Ib 1,100 Ib 550 Ib 5,586 "# 3,589 "# 4,286 "# 2,482 "# 2,423 "# 982 "# 2 pin OK 2 pin OK 2 pin OK ** Load defined as product weight per pair of beams Total: 767 Ib 575 Ib TYPE I A SELECT-REGENCY.xl5 Page / Yof l j 2/26/2O 14 $tituraI oncepts Engineering 1200 N. Jefferson Ste. Ste_F Anaheim. CA 92807 Tel: 714.632.7330 Fax: 714.632.7763 By: BOB Project: REGENCY LIGHTING Project #: 0-022114-5 Configuration & Summary: TYPE 2 SELECTIVE RACK 216" 34" 34" 34" 34" 34" 96 216" 24" 74" 52" 52" -I" 42" 1" 42" **RACK COLUMN REAC770NS ASD LOADS AXL4L DL= 250 /b AXIAL LL= 4,000lb SEISMIC AXIAL Ps=+/- 3,6151b BASE MOMENT= 8,000 in -lb Seismic Criteria # Bm Lvls Frame Depth Frame Height # Diagonals Beam Length Frame Type Ss=1.494, Fa=1 5 42 in 216.0 in 4 96 in Single Row Component Description STRESS Column Fy=55 ksi INTLK LU72/3x3x14ga P=4250 Ib, M=8957 in-Ib 0.42-0K Column & Backer None None None N/A Beam Fy=55 ksi Intik 282/3.04"deepx2"x0.07" Lu=96 in Capacity: 2496 ib/pr 0.64-OK Beam Connector Fy=55 ksi LvI 1: 2 pin OK 1 Mconn=7295 in-Ib Mcap=9726 in-Ib 0.75-OK Brace -Horizontal Fy=55 ksi _ Intlk 1-1/2x1-1/2x14ga 0.17-OK Brace -Diagonal Fy=55 ksi Intik 1-1/2x1-1/2x14ga 0.32-0K Base Plate Fy=36 ksi 8x5x3/8 I Fixity= 8000 in-Ib 0.77-0K Anchor 2 per Base 0.5" x 3.25" Embed POWERS SD2 ESR 2502 Inspection Reqd (Net Seismic Uplift=2266 Ib) 0.917-OK Slab & Soil 5" thk x 2500 psi slab on grade. 1000 psf Soil Bearing Pressure 0.51-OK Level Load** Per Level Beam Spcg Brace Story Force Transv Story Force Longit. Column Axial Column Moment Conn. Moment Beam Connector 1 1,600 Ib 34.0 in 52.0 in 97 Ib 73 Ib 4,250 Ib 8,957 "# 7,295 "# 2 pin OK 3 1,600 Ib 4 1,600 Ib 5 1,600 Ib 34.0 in 34.0 in 34.0 in 34.0 in 52.0 in 74.0 in 24.0 in 195 Ib 292 Ib 389 Ib 486 Ib 146 Ib 219 Ib 292 Ib 365 Ib 3,400 lb 2,550 Ib 1,700 Ib 850 Ib 8,679 "# 7,439 "# 5,579 "# 3,100 "# 6,764 "# 5,679 "# 4,160 "# 2,207 "# 2 pin OK 2 pin OK 2 pin OK 2 pin OK ** Load defined as product weight per pair of beams Total: 1,459 Ib 1,094 Ib TYPE 2 SELECT-REGENCY.xIs Pagel) of /1 2/26/20 14 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0089 PROJECT NAME: REGENCY LIGHTING DATE: 03/20/2014 SITE ADDRESS: 4477 S 134 PL X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 4Td4ion Public Works Fire Prevention Structural A1M 6 04' 02- ■ Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 03/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: a APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 04/22/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PACIFIC CONSTRUCTION MLTN INC Page 1 of 6 0 Washington State Department of Labor & Industries PACIFIC CONSTRUCTION MLTN INC Owner or tradesperson SLOBODEN, JACK RANDALL Principals SLOBODEN, JACK RANDALL Doing business as PACIFIC CONSTRUCTION MLTN INC WA UBI No. 601 957 855 PO BOX 1139 MILTON, WA98354 206-870-1776 PIERCE County Business type Corporation Governing persons JACK R SLOBODEN License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. PACIFCM012RH Effective — expiration 01/10/2000 —11 /17/2015 Bond CBIC Bond account no. SC4887 $12,000.00 Received by L&I Effective date 11/16/2001 11/09/2001 Insurance Catlin Specialty Insurance Co $500,000.00 Policy no. GLS-93049-1114 Received by L&I Effective date 11/14/2013 11/15/2013 Expiration date 11/15/2014 Savings No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601957855&LIC=PACIFCM012RH&SAW= 04/08/2014 THIS PERMIT /////NOT PART OF Lc„,„ NOT PART OF THIS PERMIT SITE FILE COPY Permit No. l 14 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any aged code or ordnance. Receipt of approve eondidbnsbadtnowledged: City Ofkvalla BUILDING DIVISION ROLL UP DOORS OFFICE ARE SCOPE OF WORK ACCESS DOOR e 1 e NOT PART OF THIS PERMIT MACADAM RD S t41 4 ueoll VICINITY MAP REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION e FIRE DEPARTMENT HIGH PILE STORAGE NOTES: SCOPE OF WORK: THIS PLAN IS INTENDED FOR CONSTRUCTION IT IS A HIGH PILED STORAGE DESIGN AND REPORT IN CONJUCTION WITH BUILDING STRUCTURAL PLANS. IT'S PURPOSE IT TO ESTABLISH THE STORAGE REQUIREMENTS FOR THE TENANT AND BUILDING WHICH COMPLIES WITH THE APPLICABLE 2013 INTERNATIONAL FIRE CODE, NFPA 13 2013, EDITION AND 2013 INTERNATION BUILDING CODE REQUIREMENTS. ANY AND ALL MODIFICATIONS TO THE BUILDING ARE THE SOLE RESPONSIBILITY OF THE OWNER/TENANT. THE OWNER/TENANT SHALL OBTAIN A LICENSED CONTRACTOR TO PERFORM SUCH WORK. ALONG WITH THE NECESSARY PERMIT FOR SUCH WORK. PROPOSED HIGH PILE STORAGE COMMODITIES: CLASS II COMMODITIES: PER IFC 3203.3 ALL COMMODITIES LISTED BELOW ARE CARTONED AND STORED ON WOOD PALLETS - INCANDESCENT OR FLORESCENT LIGHT BULBS IN CARTONS COMMODITY: INCANDESCENT OR FLORESCENT LIGHT BULBS IN CARTONS ALL COMMODITIES IN PARTITIONED CARDBOARD BOXES, PLACED ON WOOD PALLETS, SHRINK WRAPPED FOUR SIDES (NON -ENCAPSULATED) PLACED ON RACKS TO A HEIGHT OF 20'-0" TOP OF STORAGE CORRUGATED BOXES TO CONTAIN LESS THAN 5% OF EXPANDED GROUP A PLASTICS BY VOLU ME AND CORRUGATED BOXES TO CONTAIN LESS THAN 5% UNEXPANDED GROUP A PLASTIC BY WEIGHT. FIRE SPRINKLER DESIGN: T E CALCULATED SYSTEM HAS A MIN. DENSITY OF .34 GPM OVER THE REMOTE 2,700 SQ. FT. WITH SPRINKLER EADS W TH A TEMPERATURE RATING OF 286°F. HIG- TEMPERATURE SPRINKLER EADS WITH A 8.OK FACTOR DESIGN CRITERIA FOR RACK STORAGE: NFPA 13 (2010) REFERENCES TO TABLE 16.2.1.3.2(B) CURVE-E CLASS 11 COMMODITIES FOR STORAGE UP TO 20'-0" . THIS DESIGN REQUIRES A CEILING SPRINKLER DENSITY OF .295 GPM/3,000 SQ. FT. WIT 286°F EADS WITH MI\IMUv AISLES OF 8' 0" THIS SPRI\ KLER SYSTEV ALLOWS FOR STORAGE UP TO 20'-0" FEET OR WITHIN 18" OF SPRINKLER HEADS, WHICHEVER IS LESS FOR THE FOLLOWING CON IVODITIES: -CLASS III COMMODITIES -CONVENTIONAL PALLETS -CARTONED OR EXPOSED WAREHOUSE INFORMATION: OCCUPANCY TYPE: B (OFFICE), S-1 (WAREHOUSE / STORAGE) CONSTRUCTION TYPE: TYPE 111-B FIRE SPRINKLERS: FULLY SPRINKLED BUILDING CLEAR HEIGHT: 30'-0" FROM SLAB TO ROOF SHEATHING FIRE EXTINGUISHERS: PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN ACCORDANCE WITH 2013 CFC SECTION 906 AND TUKWILA FIRE DEPARTMENT STANDARDS FOR EXTRA HAZARD STORAGE INFORMATION + MAXIMUM STORAGE HEIGHT: STORAGE METHOD: RACK STORAGE NUMBER OF TIERS: VAX' MUM STORAGE HEIGHT: -DEPTH OF RACKS: -LONGITUDINAL FLUE SPACE: -AISLE WIDTHS BETWEEN RACKS: -WIDTH OF INDIVIDUAL BAYS: -SHELF TYPE: -WAREHOUSE AREA: -WAREHOUSE HIGH -PILE AREA: 4 & 5 BEAM LEVELS 20'-0" I- I . RACK STORAGE 3'-6" FEET 12 INCHES 9' FT - 2" INCHES MINIMU vl 96" WIDE BAYS BEAM LOADED OR WIRE MESH DECKS 4,515 SQ. FT, OF WAREHOUSE AREA 4,278 SQ. FT. OF IGH-PILE STORAGE SMOKE VENT INFORMATION + CALCULATION: PER TABLE 3206.2 OF IFC (2,501 - 12,000 SQ. FT) ALL SMOKE AND HEAT VENTS ARE NOT REQUIRED FOR HIGH PILE STORAGE WHEN HIGH PILE STORAGE AREA DOES NOT EXCEED 12,000 SQUARE FEET IN STORAGE AREA. STORAGE AREA WAS CALCULATED USING 15'-O" BEYOND THE STORAGE RACKS. COLUMN FIRE SPRINKLER PROTECTION: PER 2013 IFC 3208.4 REFERS T0: NFPA 13 TABLE (2010) TABLE 16.1.4.1 REQUIRED: BASED ON EXISTING OVERHEARD CEILING SPRINKLERS HAVING A DENSITY LESS THAN ..37 GPM (CLASS II COMMODITY) EXISTING SPRINKLER DENSITY: .34/3,000 EXISTING FIRE HYDRANTS: ACCESSIBLE HYDRANT(S) SHALL BE PROVIDED AND LOCATED WITHIN 150 FEET OF ALL PORTIONS OF EXTERIOR WALL ON THE FIRST FLOOR AS MEASURED IN AN APPROVED ROUTE AROUND THE BUILDING IN CONFORMANCE WITH CITY STANDARDS. ALL DRIVATE FIRE HYDRANT CAPS MUST BE PAINTED IN ACCORDANCE WITH TUKWILA FIRE DEPARTMENT STANDARDS IDLE PALLET STORAGE: THERE WILL BE NO DLE PALLET STORAGE IN THIS WARE OUSE AT T IS TN REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. E BUILDING ACCESS: PER TABLE 3206.2 OF IFC (2,501 - 12,000 SQ. I- I ) BUILDING ACCESS IS NOT REQUIRED (SEE PLAN FOR ACCESS ROAD AND DOORS) CURTAIN BOARD INFORMATION: PER TABLE 3206.2 OF IFC (2,501 - 12,000 SQ. I- I ) DRAFT CURTAINS ARE NOT REQUIRED REQUIRED FLUE SPACES: IFC TABLE 3208.3 LONGITUDINAL: MINIMUM 6 INCHES TRANSVERSE: MINIMUM 3 INCHES, VERTICALLY ALIGNED FIRE DETECTION SYSTEM: PER TABLE 3206.2 OF IFC (2,501 - 12,000 SQ. I- I ) A FIRE DETECTION SYSTEM IS NOT REQUIRED NOTE: FIRE DEDARTMENT FINAL INSPECTION REQUIRED. SCHEDULE ALL IN MINIMUM 48 HOURS IN ADVANCE BY CALLING (206) 575-4404 NOTE: FIRE APPARATUS ACCESS ROADS S-ALL BE UNOBSTRUCTED, ACCESS GATES S ALL BE APPROVED PRIOR TO INSTALLATION AND SHALL BE IN COMPLIANCE WITH IFC 504 AND TUKWILA FIRE DEPARTMENT STANDARDS NOTE: AUTOMATIC FIRE SPRINKLER SYSTEMS AND ALL CONTROL VALVES SHALL BE vONITORED BYA U.L. LISTED CENTRAL ALARM STATION OR BE SUPERVISED PER 2013 IFC CHAPERT 9. A SEPARATE PLAN SUBMITTAL IS REQUIRED FOR THE INSTALLATION OF THE MONITORING SYSTEM. NOTE: EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITH OUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. DOORS SHALL NOT BE PROVIDED WITH THUMB -TURN LOCKS OR DEADBOLTS THAT DO NOT UNLATCH IN TANDEM WITH THE NORMAL OPERATING LEVEL. THE OPENING FORCE FOR INTERIOR DOORS WITHOUT CLOSER SHALL NOT EXCEED 5 POUNDS THE UNLATCHING AND OPENING FORCE FOR OTHER DOORS SHALL NOT ;EXCEED 15 POUNDS I.B.C. 1008. APR 0 4 2014 City o BULLDIN ✓✓1/J kwila IVISION NOT REQUIRED REVIEWED FOR CODE COMPLIANCE APPROVED IMO SPECTIONS A NOTE: ALL EXTERIOR ACCESS DOORS SHALL BE 6'-8" X 3'—O" MAN DOORS WIT ONE MOTION HARDWARE ACG.ESSIBLE FROM INSIDE AND OUTSIDE. ALL ACCESS DOORS TO HAVE EXTERIOR LEVER HARDWARE AND ABLE TO OPEN FROM OUTSIDE. NOTE: A CFC PERMIT IS REQUIRED FOR HIGH PILE STORAGE. T-IS PERMIT WILL BE ISSUED BY AN TUKWILA FIRE DEPARTMENT FIRS INSPECTOR. NOTE: 5 YEAR SPRINKLER CERTIFICATION S REQUIRED TO BE CURRENT NOTE: PROPERTY EQUIPPED WITH FIRE DEPARTMEN NOTE: IF ANY OSE RAC CEILING T CONNECTIONS KS EXIST, THEY MUST BE REMOVED AND CAPPED OFF AT T NOTE: STORAGE, DISPENSING OR USE OF ANY FLA FLAMMABLE AND COMPRESSED GASES, A\D COMPLY WITH IFC REGULATIONS, E MMABLE AND COMBUSTIBLE LIQUIDS, OT ER HAZARDOUS MATERIALS SHALL NOTE: KNOX BOXES SHALL BE PROVIDED IN ACCORDANCE WIT TUKWILA FIRE DEPARTMENT STANDARDS, LOCATIONS SHALL BE PROVIDED BY PROPERTY OWNER KNOX BOX LOCATION LOCATED IN FRONT ENTRANCE OF OFFICE NOTE: THERE WILL NOT BE ANY FIRE SPRINKLER ALTERATIONS TO THE EXISTING SPRI\KLER SYSTEM AT THIS TIVE, IF ANY ALTERNATIONS ARE TO BE PEREQ,FI,iEIVED A SEPARATE PERMIT WILL NEEDED TO PERFORM SUC WORK CI YOFTUKWIL A NOTE: MAR 2 0 2014 THIS REVIEW DID NOT INCLUDE ANALYSIS OF ANY FLAMMABLE LIQUIDS OPERANT CENTER HAZARDOUS MATERIALS TO BE PRESENT. IF T ERE ARE TO BE ANY HAZARDOUS MATERIALS PRESENT IN EXCESS OF EXEMPT AMOUNTS, THE APPLICANT MUST PROVIDE A LETTER IDENTIFYING THE vATERIALS TO BE STORED AND/OR USED AND RETURN IT TO THE FIRE DEPARTMENT FOR REVIEW AND APPROVAL DRIOR TO INTRODUCTION OF SUCH MATERIALS INTO T E BUILDING. CODE REFERENCES: 2013 INTERNATIONAL FIRE CODE 2013 INTERNATIONAL BUILDING CODE NFPA 13 2013 EDITION The RE t : TUKWILA FIRE DEPARTMENT STAN 3 S .E. storage rant_ ..,<i..i:x'-,.Eent5; other components are. scone ,:f `dii ' e tific ;K, :. CS L or0 idcd { C7 otvAL EXPIRES 1 2§1 REVISIONS w zCL =cD r = CO CO C') J � O w ,r;:, iL damD ' I-- 0 0 r z H 00 0 IZE D N w 0 N oo • 0 ro oo 0 co N w 0 W Q 0 APPROVALS PROJECT# PWPOO75 SCALE 1"=30t-0" SHEET 1 OF 2 20' 20' 20' L)ACCE. SS DOOR FIRE DEPARTMENT HIGH PILE STORAGE NOTES: SCOPE OF WORK: THIS PLAN IS INTENDED FOR CONSTRUCTION IT IS A HIGH PILED STORAGE DESIGN AND REPORT IN CONJUCTION WITH BUILDING STRUCTURAL PLANS. IT'S PURPOSE IT TO ESTABLISH THE STORAGE REQUIREMENTS FOR THE TENANT AND BUILDING WHICH COMPLIES WITH THE APPLICABLE 2013 INTERNATIONAL FIRE CODE, NFPA 13 2013, EDITION AND 2013 INTERNATION BUILDING CODE REQUIREMENTS. ANY AND ALL MODIFICATIONS TO THE BUILDING ARE THE SOLE RESPONSIBILITY OF THE OWNER/TENANT. THE OWNER/TENANT SHALL OBTAIN A LICENSED CONTRACTOR TO PERFORM SUCH WORK. ALONG WITH THE NECESSARY PERMIT FOR SUCH WORK. PROPOSED HIGH PILE STORAGE COMMODITIES: CLASS II COMMODITIES: PER IFC 3203.3 ALL COMMODITIES LISTED BELOW ARE CARTONED AND STORED ON WOOD PALLETS - INCANDESCENT OR FLORESCENT LG-T BULBS N CARTONS COMMODITY: INCANDESCENT OR FLORESCENT LIGHT BULBS IN CARTONS ALL COMMODITIES IN PARTITIONED CARDBOARD BOXES, PLACED ON WOOD PALLETS, SHRINK WRAPPED FOUR SIDES (NON -ENCAPSULATED) PLACED ON RACKS TO A HEIGHT OF 20'-0" TOP OF STORAGE CORRUGATED BOXES TO CONTAIN LESS THAN 5% OF EXPANDED GROUP A PLASTICS BY VOLUME AND CORRUGATED BOXES TO CONTAIN LESS THAN 5% UNEXPANDED GROUP A PLASTIC BY WEIGHT. FIRE SPRINKLER DESIGN: THE CALCULATED SYSTEM HAS A MIN. DENSITY OF .34 GPM OVER THE REMOTE 2,700 SQ. FT. WITH SPR NKLER HEADS WITH A TEMPERATURE RATING OF 286°F. HIGH TEMPERATURE SPRINKLER READS WITH A 8.0K FACTOR DESIGN CRITER A FOR RACK STORAGE: NEPA 13 (2010) REFERENCES TO TABLE 1 6.2.1 ,3.2(B) CURVE-E CLASS II COMMODITIES FOR STORAGE UP TO 20'-0" . THIS DES GN REQUIRES A CEILING SPRINKLER DENSITY OF .295 GPM/3,000 SQ. FT. WITH 286°F HEADS WITH MINIMUM AISLES OF 8'-0" THIS SPRINKLER SYSTEM ALLOWS r-OR STORAGE UP TO 20'-0" FEET OR WITHIN 18" OF SPRINKLER HEADS, WHICHEVER IS LESS FOR THE FOLLOWING COMMODITIES: -CLASS III COMMODITIES -CONVENTIONAL PALLETS -CARTONED OR EXPOSED WAREHOUSE INFORMATION: OCCUPANCY TYPE: B (OFFICE), S-1 (WAREHOUSE / STORAGE) CONSTRUCTION.. TYPE: TYPE. FIRE SPRINKLERS: FULLY SPRINKLED BUILDING CLEAR HEIGHT: 30'-0" FROM SLAB TO ROOF SHEATHING FIRE EXTINGUISHERS: PORTABLE FIRE EXTINGUISHERS SHALL BE PROVIDED IN ACCORDANCE WITH 2013 CFC SECTION 906 AND TUKWILA FIRE DEPARTMENT STANDARDS FOR EXTRA HAZARD STORAGE INFORMATION ± MAXIMUM STORAGE HEIGHT: STORAGE METHOD: NUMBER OF TIERS: -MAXIMU V STORAGE HEIGHT: -DEPTH OF RACKS: -LONGITUDINAL FLUE SPACE: -AISLE WIDTHS BETWEEN RACKS: -WIDTH OF INDIVIDUAL BAYS: -SHELF TYPE: -WAREHOUSE AREA: -WAREHOUSE HIGH -PILE AREA: RACK STORAGE 4 8c 5 BEAM LEVELS 20'-0" FT. RACK STORAGE 3'-6" FEET 12 INCHES 9' ET - 2" INCHES MINIMUM 96" WIDE BAYS BEAM LOADED OR WIRE MESH DECKS 4,515 SQ. FT: OF WAREHOUSE AREA 4,278 SQ. FT. OF HIGH -PILE STORAGE SMOKE VENT INFORMATION + CALCULATION: PER TABLE 3206.2 OF IFC (2,501 - 12,000 SQ. FT) ALL SMOKE AND HEAT VENTS ARE NOT REQUIRED FOR HIGH PILE STORAGE WHEN HIGH PILE STORAGE AREA DOES NOT EXCEED 12,000 SQUARE FEET IN STORAGE AREA. STORAGE AREA WAS CALCULATED USING 15'-0" BEYOND THE STORAGE RACKS. COLUMN FIRE SPRINKLER PROTECTION: PER 2013 IFC 3208.4 REFERS TO: NFPA 13 TABLE (2010) TABLE 1 6.1 .4,1 REQUIRED: BASED ON EXISTING OVERHEARD CEILING SPRINKLERS HAVING A DENSITY LESS THAN :.37 GPM (CLASS II COMMODITY) EXISTING SPRINKLER DENSITY: .34/3,000 EXISTING FIRE HYDRANTS: ACCESSIBLE HYDRANT(S) SHALL BE PROVIDED AND LOCATED WITHIN 150 FEET OF ALL PORTIONS OF EXTERIOR WALL ON THE FIRST FLOOR AS MEASURED IN AN APPROVED ROUTE AROUND THE BUILDING IN CONFORMANCE WITH CITY STANDARDS. ALL PRIVATE FIRE HYDRANT CAPS vUST BE PAINTED IN ACCORDANCE WITH TUKWILA FIRE DEPARTMENT STANDARDS IDLE PALLET STORAGE: THERE WILL BE NO IDLE PALLET STORAGE IN THIS WAREHOUSE AT T- S TIME BUILDING ACCESS: PER TABLE 3206.2 OF IFC (2,501 - 12,000 SQ. FT) BUILDING ACCESS IS NOT ,REQUIRED (SEE PLAN FOR ACCESS ROAD AND DOORS) 2 1 6 99 TOP OH PR Q Pr' - 4497 cn •� - REVIEWED FOR E COMPLIANCE APPROVED APR 0 4 21114 CURTAIN BOARD INFORMATION: PER TABLE 3206.2 OF IFC (2,501 - 12,000 SQ, FT) DRAFT CURTAINS ARE NOT REQUIRED REQUIRED FLUE SPACES: IFC TABLE 3208.3 LONGITUDINAL: MINIMUM 6 INCHES TRANSVERSE: MINIMUM 3 INCHES, VERTICALLY ALIGNED NOT REQUIRED FIRE DETECTION SYSTEM: PER TABLE 3206.2 OF IFC (2,501 - 12,000 SQ. FT) A FIRE DETECTION SYSTEV1 IS NOT REQUIRED NOTE: FIRE DEPARTMENT FINAL INSPECT ON REQUIRED. SCHEDULE ALL INSPECT MINIMUM 48 HOURS IN ADVANCE BY CALLING (206) 575-4404 NOTE: City of Tuk w%Ia %LCING DIVISION ONS A FIRE APPARATUS ACCESS ROADS SHALL BE UNOBSTRUCTED. ACCESS GATES SHALL BE APPROVED PRIOR TO INSTALLATION AND SHALL BE IN COMPLIANCE WITH IFC 504 AND TUKWILA FIRE DEPARTMENT STANDARDS NOTE: AUTOMATIC FIRE SPRINKLER SYSTEMS AND ALL CONTROL VALVES SHALL BE MONITORED BYA U.L. LISTED CENTRAL ALARM STATION OR BE SUPERVISED PER 2013 IFC CHAPERT 9. A SEPARATE PLAN SUBMITTAL IS REQUIRED FOR THE INSTALLATION OF THE MONITORING SYSTEM. NOTE: EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITH OUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT, DOORS SHALL NOT BE PROVIDED WITH THUMB -TURN LOOKS OR DEADBOLTS THAT DO NOT UNLATCH IN TANDEM WITH THE NORMAL OPERATING LEVEL. THE OPENING FORCE FOR INTERIOR DOORS WITHOUT CLOSER SHALL NOT EXCEED 5 POUNDS THE UNLATCHING AND OPENING FORCE FOR OTHER DOORS SHALL NOT EXCEED 15 POUNDS I.B.C. 1008. NOTE: ALL T'- L E,�. EXTERIOR_ ACCESS DOORS SHALL BE 6 8 X 3' 0 VAN DOORS WITH ONE MOTION HARDWARE ACCESSIBLE FROM INS DE AND OUTSIDE. ALL ACCESS DOORS TO HAVE EXTER OR LEVER ARDWARE AND ABLE TO OPEN FROM OUTSIDE. NOTE: A CFC PERMIT IS REQUIRED FOR HIGH PILE STORAGE. THIS PERMIT WILL BE ISSUED BY AN TUKWILA FIRE DEPARTMENT F RE INSPECTOR. 2- 6" —OP O JPR G T a N- ;--. 44" L 4 99 58" 0 0 0 ^0 I -1277 96" —4 i42"if42". SELECTIVE RACK TYPE 1 46" 99 34 97 97 0 0 V J II 0 0 0 12" 96" ----Jr' �42„ SELECTIVE RACK TYPE 2 47" NOTE: 1)1+ 008? 5 YEAR SPRINKLER CERTIFICATION IS REQU RED TO BE CURRENT NOTE; PROPERTY EQUIPPED WITH FIRE DEPARTMENT CON NOTE IF ANY HOSE RACKS EXIST, THEY CEILING NOTE N ECTIONS VIUST BE REMOVED AND CAPPED OFF AT THE STORAGE, DISPENSING OR USE OF ANY FLAMMABLE AND COMBUSTIBLE L QUIDS, FLAMMABLE AND COVPRESSED GASES, AND OTHER HAZARDOUS MATERIALS SHALL COMPLY WITH IFC REGULATIONS. NOTE: KNOX BOXES S-ALL BE PROVIDED IN ACCORDANCE WIT TUKWILA FIRE DEPARTS STANDARDS, LOCATIONS S-ALL BE PROVIDED BY PROPERTY OWNER KNOX BOX LOCATION LOCATED IN FRONT ENTRANCE OF OFFICE NOTE: ENT z rn w 0 0 0 04) 0 0 w 1 0 0 0 0 00 0 rj Eu), r 0 1- U a T-ERE WILL NOT BE ANY FIRE SPRINKLER ALTERAT ONS TO T-E EXISTING RECEIVED SPRINKLER SYSTEM AT THIS T1VE, F ANY ALTERNATIONS ARE TO BE PER FOCIT'EOFTUKWILA A SEPARATE PERMIT W LL NEEDED TO PERFORM SUCH WORK NOT.:._: PERMIT CENTER TH S REVIEW DID NOT INCLUDE ANALYSIS OF ANY 'FLAMMABLE LIQUIDS OR HAZARDOUS MATERIALS TO BE PRESENT. IF T-ERE ARE TO BE ANY HAZARDOUS MATERIALS PRESENT IN EXCESS OF EXEMPT AMOUNTS, • THE APPLICANT MUST PROVIDE A LETTER IDENTIFYING THE VAT ERIALS TO BE STORED AND/OR USED AND RETURN IT TO THE FIRE DEPARTMENT FOR REVIEW AND APPROVAL PRIOR TO INITRODUCTION OF SUC MATERIALS INTO THE BUILD Na CODE REFERENCES: 2013 INTERNATIONAL FIRE CODEherein 2013 INTERNATIONAL BUILD NG CQ,Q, NFPA 13 2010 EDITION_ a° } TUKWILA FIRE DEPARTMENT STANDARDS _. St The P, or .fl k, JO- } MAR 2 0 2014 cf] H N CO Cs <1 N. 0 I co z 0 0 v) w 0 DISCLOSED TO 0 LJ- 0 0 r w a_ 0 cc u) 0 1- w 0 0 0 0 CC 0 V) CL 0 0 w 0 a a_ w 0 w 0 0 0 0 CC 0 0 1- Q 0 et- 0 APPROVALS w 0 W 0 w > 0 SIZE . D PROJECT#�/ P !' � P00 //�//5 J��+p/y CALE "=10'-0" SHEET 2 OF 2 41in ' 311 " COLUMN 5" NOTES: USE @ ALL INTERLAKE COLUMN/BASE LOCATIONS TYP. 3/8"- TYP. 1/2" 1 1/2" DESCRIPTION BASE PLATE: 8" x 5" DESCRIPTION COLUMN: INTLK LU72 DESCRIPTION BRACING: HORIZ. & DIAG. MATERIAL 3/8" THICK PLATE MATERIAL 14 GAGE THICK STEEL MATERIAL 14 GAGE STEEL STEEL YIELD ASTM A36, Fy=36,000 PSI 1 5/8" STEEL YIELD ASTM A570, Fy=55,000 PSI 1/8"/ " " <TYP. fL 3" TYP. > 1 /8„ / DESCRIPTION 2-PIN CONNECTOR MATERIAL 7 GAGE STEEL YIELD ASTM A570, Fy=55,000 PSI. NOTES: USE @ ALL INTERLAKE BEAM TO COLUMN CONNECTION LOCATIONS TYP. STEEL YIELD ASTM A570, Fy=55,000 PSI 216" NOTES: USE @ ALL INTERLAKE BRACE LOCATIONS TYP. TYPE 1 SELECTIVE RACK 6" 44" 44" 44" 58" FRONT VIEW TYPE 1A SELECTIVE RACK 216" 44" 44" 58" FRONT VIEW HORIZ. BRACE DIAG. BRACE GENERAL CONFIGURATION ROW SPACER OLUMN EAM CONNECTOR BASE PLATE NOT A DEPICTION OF THIS PROJECT TYPE 2 SELECTIVE RACK (DR) 216" 34" 34" 34" 34" 34" FRONT VIEW 14-42n fl2 T n 24" 74" ft SIDE VIEW n STORAGE RACK ELEVATIONS DESCRIPTION 1" / 1" / // 3.04" BEAM (INTLK 282) 3/4" 3 1 /32" 1 3/4" 1.///////// / / / / / / / / / / /// / .r / / / / / 1 5/8" 4 1/32" BASE PLATE F.F. 3 1/4" MIN. EMBED. L. MATERIAL 14 GAGE STEEL YIELD ASTM A570, Fy=55,000 PSI NOTES: USE @ TYPE 1 & 2 INTERLAKE BEAM LOCATIONS TYP. DESCRIPTION MATERIAL STEEL YIELD 4.04" BEAM (INTLK 485) 14 GAGE ASTM A570, Fy=55,000 PSI NOTES: USE @ TYPE 1A INTERLAKE BEAM LOCATIONS TYP. DESCRIPTION POWERS SD2 MATERIAL ESR# 1/2" X 3-1/4" MIN. EMIBED. 2502 NOTES: SEE NOTE #4 ABOVE FOR ANCHOR SPECS GENERAL PROJECT NOTES 1. DESIGNED PER THE REQUIREMENTS OF THE 2012 IBC, 2008 RMI RACK DESIGN MANUAL 2. SEISMIC CRITERIA Ss = 1.494, S1 = 0.560, Fa = 1.000, Fv = 1.500 Ip = 1.0 (NO PUBLIC ACCESS), SdS = 0.996, Sd1 = 0.560, OCC CATAG. II, SITE CLASS D, SEISMIC DESIGN CATAG. D 3. STORAGE CAPACITY: TYPE 1: 1500# PER LEVEL TYP. TYPE 1 A: 1000# PER LEVEL TYP. TYPE 2: 1600# PER LEVEL TYP. 4. ANCHORS : POWERS SD2 ESR #2502 1/2"0 x 3-1/4" MIN. EMBEDT. AS USED IN CALCULATIONS OR ICC & ENGINEER APPROVED EQUAL. (2) ANCHOR PER BASE PLATE 5. PERIODIC SPECIAL INSPECTION IS REQUIRED DURING ANCHOR INSTALLATION. 6. EXISTING S.O.G. CONCRETE THICKNESS & COMPRESSIVE STRENGTH, 5" x 2500 PSI OR BETTER 7. SOIL BEARING PRESSURE 1000 PSF @a GRADE OR BETTER 8. ALL RACK INSTALLATIONS AND RACKS MANUFACTURED IN CONFORMITY WITH THIS STANDARD SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT PLAQUE EACH NOT LESS THAN 50 SQUARE INCHES IN AREA AND SHOWING THE MAXIMUM PERMISSIBLE UNIT LOAD IN CLEAR, LEGIBLE PRINT. 9. ALL BOLTS GR. 5 OR BETTER. INSTALL TO SNUG TIGHT FIT WITH ALL PLYS IN FLAT CONTACT 10. ALL WELDING PERFORMED IN THE SHOP OF AN APPROVED FABRICATOR BY AWS CERTIFIED WELDERS USING E70XX ELECTRODE OR BETTER. FIELD WELDS, IF ANY, SHALL BE PROVIDED UNDER THE SUPERVISION OF A LICENSED DEPUTY INSPECTOR. 11. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE AMIN. OF 18" BETWEEN TOP OF THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. REVIEWED FOR CODE COMPLIANCE APPROVED APR 04 2014 City of Tukwila BUILDING DIVISION R I 12014 bi'+OO�'1 ��OLILt, -RECEIVED CITY OF TUKWILA MAR 2 0 2014 O y W Q G a y f JOB NO. 0-022114-5 SHEET NO. SCE IOF1 PERMIT CENTER