Loading...
HomeMy WebLinkAboutPermit D14-0215 - ANDOVER EXECUTIVE PARK - BUILDING 4 REROOFANDOVER EXECTJTIVE PARK BLDG 4 530 INDUSTRY DR D14-0215 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT 0223400010 530 INDUSTRY DR BLDG 4 Project Name: ANDOVER EXECUTIVE PARK BLDG 4 Permit Number: D14-0215 Issue Date: 7/23/2014 Permit Expires On: 1/19/2015 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BLUE DOG PROPERTIES TRUST PO BOX 847 C/O THOMSON REUTERS PTS, CARLSBAD, WA, 92018 STEVE STONE 9500 AURORA AVE N , SEATTLE, WA, 98103 TECTA AMERICA SEATTLE LLC 9500 AURORA AVE N , SEATTLE, WA, 98103 TECTAAS905DH NCWP ANDOVER PARK LLC 810 NW MARSHALL ST #300 , PORTLAND, OR, 97209 Phone: (206) 522-5436 Phone: (425) 881-9190 Expiration Date: DESCRIPTION OF WORK: REROOF BUILDING. TPO SINGLE PLY FULLY ADHERED. EXISTING ROOF 1 LAYER BUR CAPSHEET Project Valuation: $91,500.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $2,432.86 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: I hearby certify that I have read and : • d this permit and know the same to be true and correct. All provisions of law and ordinances gov his work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: :S Z frk W irriYIl Date: D 7 11( This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0612 EXT ROOFING INSUL 0103 PRE-REROOF CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. t 4t-- ems - Project No. Date Application Accepted: 7"t i--14 Date Application Expires: `Y%•S (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 530 Industry Dr. Tukwila WA 98188 Suite Number: roof Floor: Tenant Name: 4►, einv c./ T e+cty [ (fA LA New Tenant: ❑ Yes ❑ ..No PROPERTY OWNER Name: ncwp Andover execitive park LLC Address: 810 NW Marshall St #300 City: Portland State: OR Zip: 97209 CONTACT PERSON — person receiving all project communication Name: Steve Stone Address: 9500 Aurora Ave N City: Seattle State: wa Zip: 98103 Phone: (206) 522-5436 Fax: (206) 522-5472 Email: sstone@tectaamerica.com GENERAL CONTRACTOR INFORMATION Company Name: Tecta America Seattle LLC Address: 9500 aurora ave N City: Seattle State: wa Zip: 98103 Y Phone: (206) 522-5436 Fax: (206) 522-5472 Contr Reg No.: TECTAAS905DH Exp Date: 07/01/2Q15 Tukwila Business License No.: 0994534 H:\Applicrtions\Forms-Applications On Line \2011 Applicatioos\Pamit Application Revised - 11-9-11.docc Revised: August 2011 bh ARCHITECT OF RECORD Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: N cLi ,() U /�� (d le— 1- L Address: `.C� itilki ' —/5 1-_, 4\ d i 3 City: () km State: 0 -{ Zip:e l 12C Page 1 of 4 BUILDING PERMIT INFORMATIO. - 206-431-3670 Valuation of Project (contractor's bid price): $ 91,500 Describe the scope of work (please provide detailed information): Reroof building. See attached. TPO single ply fully adhered. ex 5 Existing Building Valuation: $ \ \ ey..t.r (9151-ie-dC_ Will there be new rack storage? ❑ Yes m.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC Ist Floor 2nd Floor X q / / 0 o. 1 '"� 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: Floor area of accessory dwelling: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm 0 None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ® No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 1 • PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Stephen Forbes Mailing Address: 9500 Aurora Date: 07/11/2014 Day Telephone: (206) 793-3438 seattle WA 98103 City State ZIP H:\Applications\Forms-Applications On L ne12011 Applcations\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 4 of 4 DESCRIPTIONS PermitTRAK Cash Register Receipt City of Tukwila ACCOUNT ( QUANTITY PAID 18.10 D14-0214 Addre 400 INDUSTRY DR Apn: 0223400010 2,000.38 DEVELOPMENT $1,941.68 PERMIT FEE R000.322.100.00.00 0.00 $1,174.05 PLAN CHECK FEE R000.345.830.00.00 0.00 $763.13 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $58,70 TECHNOLOGY FEE R000.322.900.04.00 0.00 $58.70 D14-0215 Address: 530 INDUSTRY DR BLDG 4 Apn: 022340001 2,432.86 DEVELOPMENT $2,361.44 PERMIT FEE R000.322.100.00.00 0.00 $1,428.45 PLAN CHECK FEE R000.345.830.00.00 0.00 $928.49 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $71.42 TECHNOLOGY FEE R000.322.900.04.00 0.00 $71.42 D14-0216 Address: 596 INDUSTRY DR Apn: 0223400010 2,180.58 DEVELOPMENT $2,116.58 PERMIT FEE R000.322.100.00.00 0.00 $1,280.05 PLAN CHECK FEE R000.345.830.00.00 0.00 $832.03 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $64,00 TECHNOLOGY FEE R000.322.900.04.00 0.00 $64.00 D14-0217: Address. 698 INDUSTRY DR Apn: 2523049008 2,704.28;' DEVELOPMENT $2,624.87 PERMIT FEE R000.322.100.00.00 0.00 $1,588.10 PLAN CHECK FEE R000.345.830.00.00 0.00 $1,032.27 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $79.41 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2569 R000.322.900.04.00 0.00 $79.41 $9,318.10 Date Paid: Friday, July 11, 2014 Paid By: STEPHEN FORBES WRS SEATTLE TEC Pay Method: CREDIT CARD 09343G Printed: Friday, July 11, 2014 2:43 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit -D2t CITY OF TUKWILA BUILDING DIVISION Ott 6300 Southcenter Blvd..1I100, Tukwila. WA 98188 (206) 431-367I Permit Inspection Request Line (206) 438-9350 11 *Ow: 'Type MO t1,1 c—iCPf . l�j4r� , Inspection: t I OJ' F. #t 7 ' s 6 il-S�f. daft Spe Instn�tionss:, lief,\t Date Wanted: h{ p.rrr, Requester. Phone No: Appreeed Per applicable codes. Corrections required prior to approval. COMMENTS: p'(.7-4, ityltie Ins • Date: 0E RR P ION FEE REQUIRED. Prior to next inspection. fee must be . paid at 6300 Southcentsr Blvd.. Suite 100. CaU to schedule reinspection. INSPECTION RECORD Retain a copy with permit INS PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Port I� v c �P f �Ai Type o �pectjp`t� f Addr : @ ,i)swi Date lied: cial Instructions: ff i ( • Date Wanted p.m. /4, 'Requester: Phone No: Approved.per applicable codes. CONAMENTS: Corrections required prior to approval. 4--cvr h -Ti-A( aA ) Avg �' gykrradtry Ins Date 4 ❑ REINSPECTION PE€ REQUIRED. Prior to next inspection. fee must be paid at 6300 SouthcenterBlvd.. Suite 100. Calk to, schedule reinspection. INSPECTION RECORD Retain a copy with permit IN P T . PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431.-3670'. Permit Inspection Request Line (206) 431-2451 Project: Ptiki 0 a U el g)( rAfIC Type oUspectio . _ ,... ..-- Ikt_.,-1(-- �� Address 3 0 r.A.A9 Date (Lille Spedal Instructions: & t'j A 7 Date Wanted: Requester: Phone No: roved per applicable codes. aCorrections required prior to approval. COI 4ENTS:. Date: REINSPECTION FEE REQUIRED. Prior to next inspection, lee must be paid at 6300 Southcenter Btvd Suite .100,E CaJ1 tO schedule reinspection. VERSICO TOTAL ROOFING SYSTEM WARRANTY (With Limited Coverage For Hail) Versico, a division of Carlisle Construction Materials Incorporated (Versico), warrants to the Building Owner (Owner) of the building described below, that subject to the terms, conditions, and limitations stated in this warranty, Versico will repair any leak in the Versico Total Roofing System (1/wilco Roofing System) installed by a Versico Authorized Roofing Contractor for a period of 10 years commencing with the date of Versico's acceptance of the Versico Roofing System installation. However, in no event shall Versico's obligations extend beyond 10.5 years subsequent to the date of substantial completion of the Versico Roofing System. See below for exact date of warranty expiration. The Versico Roofing System is defined as the following Versico Materials: Membrane, Fleshings, Adhesives and Sealants, Fastener Assemblies, Metal Edging, Insulation, Cover Boards, Metal Work, Insulation Adhesives and any other Versico brand products utilized in this installation. TERMS, CONDITIONS, LMRATIONS 1. Owner shall provide Versico with written notice via letter, fax or email to the address printed below within thirty (30) days of the discovery of any leaks in the Versico Roofing System. Owner should send written notice of a leak to Versico's Warranty Services Department at the address set forth at the bottom of this warranty. By so notifying Versico, the Owner authorizes Versico or its designee to investigate the cause of the leak. Should the investigation reveal the cause of the leak to be outside the scope of this warranty, investigation and repair costs for this service shall be paid by the Owner. 2. If, upon inspection, Versico determines that the leak is caused by a defect in the Versico Roofing System's materials, or workmanship of the Versico Authorized Roofing Contractor in installing the same, Owner's remedies and Versico's liability shall be limited to Versico's repair of the leak. 3. This Warranty shall not be applicable 11 Versico determines that any of the following has occurred: (a) The Versico Roofing System is damaged by natural disasters, including, but not limited to, lightning, fire, insect infestation, earthquake, tornado, hurricanes, or winds of (3 second) peak gust speeds of fifty-five mph or higher measured at 10 meters above ground, and hail greater than 1 inches in diameter (as reported by the National Climatic Data Center). Versico shall not be responsible for any changes in appearance of surface imperfections caused by hail incidents. (b) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other envelope components or from roof damage by wind-blown objects, or: (c) The Versico Roofing System is damaged by any act of negligence, accidents, or misuse, including but not limited to excessive traffic, recreational activities, storage of materials on the roof, vandalism, or civil disobedience; or (d) The Versico Roofing System is damaged by infiltration of moisture in, through, or around walls, skylights, vents, copings, HVAC units, building structures, or underlying or surrounding areas; or (e) The Versico Roofing System is damaged by the building structure failing to have adequate strength to support all live and dead loads, including water and snow loads, or by any other structural defects or failures; or (f) The Versico Roofing System is damaged by settlement, distortion, cracking, movement or failure of the roof substrate, coping, walls, structural members or components adjacent to the roof or foundation of said building; or (g) The Versico Roofing System is damaged as a result of attack by roof top contaminants such as solvents, petroleum, oil products, OWNER: SKB PROPERTIES BUILDING: ANDOVER BUSINESS PARK 530 INDUSTRY DRIVE, TUKWILA, WA ROOFER: TECTA AMERICA SEATTLE, LLC 9600 AURORA AVENUE N, SEATTLE, WA 98103 DATE INSTALLATION COMPLETED: 10/07/2014 DATE OF ACCEPTANCE BY VERSICO: 10/08/2014 WARRANTY EXPIRATION DATE: 10/07/2024 `/0 VERSICO ROOFING SYSTEMS P.O. Box 1289 Carlisle, PA 17013 (800) 992-7663 (717) 960,403.5 FAX VSW4 Rev 8/13 acids or other harmful chemicals; or (h) The Versico Roofing System encounters a leak or is otherwise damaged by condensation resulting from any condition within the building that may generate moisture. 4. This Warranty shall be null and void if any of the following shall occur. (a) If, after installation of the Versico Roofing System by a Versico Authorized Roofing Contractor, there are any alterations or repairs made on or through the roof, or objects such as, but not limited to, structures, fixtures, solar panels, wind turbines, roof gardens or utilities are placed upon or attached to the roof without first obtaining written authorization from Versico, or (b) Failure by the Owner to use reasonable care in maintaining the roof, said maintenance to include, but not limited to, those items on Versico's Care and Maintenance information sheet which accompanies this Wananty. 5. During the term of this Warranty, Versico shall have free access to the roof during regular business hours. 6. Versico shall have no obligation under this Warranty while any bills for installation, supplies, services, and warranty charges have not been paid in full to the Versico Authorized Roofing Contractor, Versico, or material suppliers. 7. Versico's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 8. This warranty is not assignable by operation of law or otherwise. Application may be made by a new building owner for reissuance of the warranty during the original warranty period. Certain procedures, including an inspection of the Versico Roofing System by a Versico representative, and fees will apply to any reissuance. Versico reserves the right, in its sole discretion, to refuse to reissue this warranty. 9. Only Versico brand insulations are covered by this warranty. Versico specifically disclaims liability, under any theory of law for damages sustained by or caused by non-Versico brand insulation products. 10. Versico shall not be responsible for the cleanliness or discoloration of the Versico Roofing System caused by environmental conditions, including but not limited to , dirt pollutants or biological agents. 11. Versico shall have no liability under any theory of law for any claims, repairs, restoration, or other damages including, but not limited to, consequential or incidental damages, relating, directly or indirectly, to the presence of any irritants, contaminants, vapors, fumes, molds, fungi, bacteria, spores, mycotoxins, or the like in the building or in the air, land, or water serving the building. VERSICO DOES NOT WARRANT PRODUCTS UTILIZED IN THIS INSTALLATION WHICH IT HAS NOT FURNISHED; AND SPECIFICALLY DISCLAIMS LIABILITY, UNDER ANY THEORY OF LAW, ARISING OUT OF THE INSTALLATION AND PERFORMANCE OF, OR DAMAGES SUSTAINED BY OR CAUSED BY, PRODUCTS NOT FURNISHED BY VERSICO OR THE PRIOR EXISTING ROOFING MATERIAL OVER WHICH THE VERSICO ROOFING SYSTEM HAS BEEN INSTALLED. THE REMEDIES STATED HEREIN ARE THE SOLE AND EXCLUSIVE REMEDIES FOR FAILURE OF THE ROOFING SYSTEM OR ITS COMPONENTS. THERE ARE NO WARRANTIES EITHER EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY, WHICH EXTEND BEYOND THE FACE HEREOF. VERSICO SHALL NOT BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR OTHER DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR DAMAGE TO THE BUILDING OR ITS CONTENTS UNDER ANY THEORY OF LAW. (ER Warranty) PECNIMID ..r+r,.++�M� DEC 042014 N:rtMil CENTER WARRANTY NUMBER: 1164035 VERSICO, a division of Carlisle Construction Materials Incorporated BY tLt4 0245 • FILE COPY 0 0. a o "co • N N CNI re 0 rc a a ' crs 0 V 'Co 0 m 0 E 0 c 0 , 0 0 i 0 a Permit Na bl40h1Sw Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field Copy and conditions is acknowledged: By: c5igt" W(-11 1-ced Data: IP 7-7-23—/41 0 • City of Tukwila BUILDING DIVISION ® ® 0 ° 0 0 0 0 0 ❑ ❑ 0 0 0 0 PS 0 0 ❑ ❑ ❑ 00 O 0 BUILDING 530 ROOF PLAN SCALE: 1 "=20'-0" GRADE EL. APPROX. 100'-0" (ASSUMED) REVISIONS No changes shall be made to the scope of work without prior approval of T u'ciuila Building Division. NOTE: rovisions will require a new plan submittal and may include additional plan review fees. i 1 North DESIGN NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR THE VERIFICATION OF ALL DIMENSIONS, EXISTING DETAILS AND CONDITIONS PRIOR TO SUBMITTING BID AND STARTING WORK. 2. DETAILS SHOWN REPRESENT EXISTING CONDITIONS TO THE EXTENT KNOWN, WITH THE NEW MATERIALS AND/OR PROCEDURES CALLED OUT. 3. TPO UNDERLAYMENTS, WHEREVER SPECIFIED, SHALL BE BONDED AT ALL LAPS. 4. CONTRACTOR SHALL COORDINATE ALL CONDUIT/GAS UNE DISCONNECTS AND RECONNECTS WITH OWNER, AND PROVIDE AND INSTALL NEW TREATED WOOD CONDUIT/GAS LINE SUPPORTS AT A SPACING TO MEET CODE AS REQUIRED. 5. ALL MEANS OF ACCESS AND EGRESS MUST REMAIN UNOBSTRUCTED. COORDINATE STAGING AREA WITH OWNER. ALL STAGING AREAS ARE TO BE RETURNED TO ORIGINAL OR BETTER THAN ORIGINAL CONDITIONS UPON COMPLETION OF THE WORK. 6. AT DETERIORATED WOOD EQUIPMENT SUPPORTS, PROVIDE AND INSTALL NEW TREATED W000 SUPPORTS SIZED TO MATCH EXISTING. SEE SUMMARY OF WORK PARAGRAPH t. EXISTING GUTTERS TO REMAIN. PROVIDE AND INSTALL NEW TPO CLAD DRIP EDGE METAL CLERESTORY WINDOWS SEPARATE PERMIT REQUIRED FOR WMei hand tirbectrical esimbing as Pipblg City of Tukwila eSt.fi%_c iNG DIVISION GENERAL NOTES: BUILDING 530 1. EXISTING ROOF SYSTEM: • EXISTING 2—PLY MODIFIED BITUMEN MEMBRANE (MOPPED). • EXISTING 3/4" PERUTE INSULATION. • EXISTING 5/8" WOOD ROOF DECK. 2. NEW ROOF SYSTEM: • NEW 100 MIL FLEECE BACKED TPO MEMBRANE (SET IN FOAM ADHESIVE). • EXISTING 2—PLY MODIFIED BITUMEN MEMBRANE. • EXISTING 3/4" PERUTE INSULATION. • EXISTING 5/8" WOOD ROOF DECK. / / ROOF PLAN SYMBOLS: PS 0 0 • 0 NEW PRIMARY SCUPPER AT EXISTING LOCATION (SEE SUMMARY OF WORK PARAGRAPH a.) (SEE DETAIL 1/6) VENT STACK (SEE DETAIL 2/5) HEAT STACK (SEE DETAIL 2/6) PIPE PENETRATION (SEE DETAIL 2/5) UNIT CURB SLEEPER CURB SATELLITE DISH STRUCTURAL SLOPE / Copyright © SRI Consultants, Inc. 0) 1 yi i� l■ cn 4) C 0 CL 0 U 0 m 0 E 4) 0 C 0 0 V) ANDOVER EXECUTIVE PARK 2014 ROOF RECOVER b od.2. is REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2014 City of TukwiOtt la BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 112014 PERMIT CENTER To: Phone: Cell: From: Date: SRI Consulting 763-533-2727 612-310-5602 Steve Stone June 13, 2014 TECTAAMERICA Project: SKB Bldg 530 Address: 400 Industry Dr Tukwila WA Thank you for the opportunity to present a Tecta America Seattle quality proposal for your project Tecta America Seattle is a division of Tecta America, North America's tM choice for roofing. Tecta is #1 because we have the best qualify end financial strength in the industry. That is why Tecta America Seattle Is your best and safest choke. FILE COPY Pli".0.44 Mira Scope of Work 1) Remove the existing metal copings and dispose. 2) Demo off all of the base flashings from the walls, curbs and penetrations. 3) Mechanically attach tapered crickets on the high side of all units and curbs. 4) Cut out and repair all blisters and wrinkles in the roof field. 5) Clean the entire roof surface and remove all of the debris. 6) Fully adhere Versico 45 mil fleece back TPO membrane to the existing roof. 7) Fully adhere 60 mil TPO to all walls, curbs and roof top penetrations. 8) Install all necessary pre -molded TPO pipe flashings where required. s) Fabricate and install new 26g standing seam pre -finished metal copings with continuous metal dip and fastened on the inside of the wall. 10) Upon completion and payment received supply a 10 year warranty on materials and labor. Remove 20ft of roofing below windows and install taper iso to help move water from 11) away windows. ADD / Deduct Add: Plywood replacement if needed wiH be billed at $95.00 per sheet Exclusions/Clarificatlons Exclude ponding water, interior work, satellite or cable TV interruptions. Exclude asbestos abatement, electrical, structural and Mechanical repairs. Exclude dry time, Permit fees, and low spots cause by defections of roof decks Quotation $91,500 Not Including WSST We look forward to adding to our long list of successful projects. When you choose Tecta America Seattle you have made a quality decision. Sincerely, Steve Stone Tecta America Seattle 206-455-7459 Approved By: Tile: Date: / /2014 Please Print Name: 9500 Aurora Ave N. Seattle. WA 98103 Dir 206-455-7459 Fax 206-522-5472 www.tecfaamerica.corn WA Lic TECTAAS905DH REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 1 1 2014 PERMIT CENTER VERSICO ROOFING SYSTEMS FULLY ADHERED ROOFING SYSTEM WITH DASHTM ADHESIVE Colors: White, Gray, Tan Thicknesses (mils) TPO + Fleece: 100, 115 and 135 Standard Widths: 6' and 12' Standard Lengths: 50', 75' and 100' INSTALLATION Versico's VersiWeld VersiFleece Fully Adhered Roofing System utilizes 45-, 60- or 80-mil white, gray or tan VersiWeld thermoplastic polyolefin (TPO) membrane laminated to a non -woven polyester fleece backing. DASH Adhesive, a low-rise insulating, two -component spray - applied polyurethane adhesive, is used to adhere insulation to the substrate. DASH Adhesive is then sprayed onto the insulation and VersiWeld VersiFleece membrane is rolled into the foamed adhesive after it develops string/body. Adjoining sheets are hot-air welded to form a monolithic assembly. The above information represents a typical Versico VersiWeld Fully Adhered Roofing System application. Refer to Versico's published specifications and details for more complete Information. VERSICO ROOFING SYSTEMS TYPICAL APPLICATION VersiWeld® VersiFleece® Membrane 0 DASH' Adhesive Acceptable Insulation al Approved Roof Deck Verslco, • e :ox . , 7013 Tel: 800.992.7663 Fax: 717.960.4036 Web: www.verslco.com 4*ZgrAdo VERSIFLEEcE CERTIFIED FABRICATED ACCESSORIES Certified Fabricated Accessories (CFAs) are the only factory -fabricated TPO accessories that meet the stringent quality tolerances required to be included in a warranted Versico TPO roofing system, SYSTEM CODES • UL Class A and B ratings are available over various deck types. • FM codes are available ranging from FM 1-90 to FM 1-990 For code specifics, also refer to Versico's Code Approval Guide. QUALITY ASSURANCE Versico Authorized Contractors have been trained to install Fully Adhered Roofing Systems INSPECTION Upon installation completion, and prior to the issuance of a system warrranty, an inspection will be conducted by a Versico Field Service Representative. EXISTING OR NEW DECK TYPE INSULATION. REQUIRED RECOMMENDED INSULATIONS INSULATION ATTACHED BY MEMBRANE ATTACHED BY WARRANTY Consult your Authorized Contractor or Versico Independent Sales Representative or Distributor for associated warranty charges. Provided all materials are manufactured or marketed by Versico, this system properly installed and inspected on a commercial project may receive: Total System Warranty Options h TPO Fully Adh 5-Year l0-Year 15-Year 20-Yeor 25-Year 30-Year 100-Mil 115-Mil X X X X X X 135-Mil X X X X X X • A maximum peak gust wind speed coverage of 120 mph is available with design enhancements • 10-year Reflective Warranty (based on ENERGY STAR criteria) is available for white membrane • Hail resistance warranty may be included for up to 1" hail for 100-mil VersiFleece, up to 2" hail for 115-mil VersiFleece and up to 3" hail for 135-mil VersiFleece • Limited accidental puncture warranty is also available when using 115-mil or thicker VersiFleece For more specifics on warranty programs, contact Versico. VERSICO POLYISO, NEW CONSTRUCTION LT. WT, CONCRETE STRUCTURAL WOOD CONCRETE PLANKS GYPSUM & FIBROUS CEMENT OVERY BOARD, DENSDECK OR SECUROCK OVER ACCEPTABLE INSULATION DASH ADHESIVE SMOOTH SURFACED BUR REROOFING GRAVEL- URFACED BUR EXISTING SINGLE -PLY REFER TO NEW CONSTRUCTION EFER TO NEW CONSTRUCTION FOR TEAR -OFF OPTIONS REFER TO NEW CONSTRUCTION ABOVE. For current code approvals and warranties, visit Versico's web site or contact a design analyst. Refer to Versico's VersiWeld VersiFleece TPO current specifications. OCTRGURRO XT WEATHERING PACKAGE Certif,ed \ Fabricated Accessory APPROVED ENERGY STAR 40 2012 Version Printed in U.S A. REPRINT REQUEST CODE: CO'ilb s-"versirinece TPO RASH Adhestvi, Systrfn Sheer' • 10.1212 NER0Y STAR is 0 iegrstered trodrrnork gwn. 4Per51c0, 1dnt5iYV8ld'1•'ersi F)oece. DASH, QGtoG i nd f T Dnd the Ver51Qo logo are registered traderngrk5 of VerooCo. U.S Govetr,menl ' ENERPOY STAR qucr o)icUtioti is only vo0) m the 0.S. Go: earth feet' meters 200 900 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2014 City of Tukwila BUILDING DIVISION City of Tukwila Department of Community Development 12/1/2014 STEVE STONE 9500 AURORA AVE N SEATTLE, WA 98103 RE: Permit No. D14-0215 ANDOVER EXECUTIVE PARK BLDG 4 530 INDUSTRY DR Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/24/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/24/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, 1>tj Bill Rambo Permit Technician File No: D14-0215 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D14-0215 DATE: 07/11/14 PROJECT NAME: ANDOVER EXECUTIVE PARK - BUILDING 4 SITE ADDRESS: 530 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: G1:"(`I Build16f-in Division g Public Works ❑ iih re Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 07/15/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required E Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 08/12/14 Notation: REVIEWER'S INITIALS: DATE: CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 TECTA AMERICA SEATTLE LLC Page 1 of 3 45 Washington State Department of Labor & Industries TECTA AMERICA SEATTLE LLC Owner or tradesperson GRINAKER, STEVEN LYLE Principals GRINAKER, STEVEN LYLE, MANAGER GRINAKER-KRUSE, ERIN JANEANE, MANAGER REGINELLI, DAVID R, MANAGER SMITH, BRYNNE E, MANAGER KRACHT, TODD N, PARTNER/MEMBER (End: 06/24/2013) SONTACRONE, MARK F, PARTNER/MEMBER (End: 06/24/2013) FORBES, STEPHEN A, MANAGER (End: 06/24/2013) Doing business as TECTA AMERICA SEATTLE LLC WA UBI No. 602 730 183 9500 AURORA AVE N SEATTLE, WA 98103 425-881-9190 KING County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. TECTAAS905DH Effective — expiration 03/08/2010— 07/01 /2015 Bond American States Insurance Co $12,000.00 Bond account no. 17S003756 Received by L&I Effective date 05/07/2012 04/20/2012 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602730183&LIC=TECTAAS905DH&SAW= 07/23/2014