Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit EL14-0139 - COSTCO - ELECTRICAL FOR FUEL FACILITY
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. EL14-0139 COSTCO –GASOLINE 451 Costco Drive DIGITAL RECORDS (DR)EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDESTHE FOLLOWING REDACTED INFORMATION Page #CodeExemptionBrief Explanatory DescriptionStatute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern.As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers individuals’ privacy pursuant to 5 U.S.C.sec. 5 U.S.C. sec. 552(a), and are also exempt from disclosure 552(a); RCW DR1Generally –5 U.S.C. sec. under section 42.56.070(1) of the Washington 42.56.070(1) 552(a); RCW State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW account numbers, which are exempt from 19DR2Financial Information – 42.56.230(5) disclosurepursuant to RCW 42.56.230(5), RCW 42.56.230(45) except when disclosure is expressly required by or governed by other law. Personal Information – Redactions contain information used to prove RCW Driver’s License. –RCW identity, age, residential address, social security 42.56.230 (7a DR3 number or other personal information required to 42.56.230 & c) apply for a driver’s license or identicard. (7a & c) Redacted content contains a communication between client and attorney for the purpose of obtaining or providing legal advice exempt from RCW Attorney-Client Privilege –disclosure pursuant to RCW 5.60.060(2)(a), 5.60.060(2)(a); RCW 5.60.060(2)(a); RCW which protects attorney-client privileged DR4 RCW 42.56.070(1)communications, and RCW 42.56.070(1), which 42.56.070(1) protects, under the PRA, information exempt or prohibited from disclosure under another statute. COSTCO GASOLINE 451 COSTCO DR EL14-0139 City of Tukwila Department of Community Development O 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 1908 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov ELECTRICAL PERMIT Parcel No: 3623049107 Permit Number: EL14-0139 Address: 451 COSTCO DR Issue Date: 4/4/2014 Permit Expires On: 10/1/2014 Project Name: COSTCO GASOLINE Owner: Name: COSTCO WHOLESALE CORP Address: 999 LAKE DR PROPERTY TAX DEPT 190, ISSAQUAH, WA, 98027 Contact Person: Name: KENDALL WILLIAMS Phone: (425) 463-1252 Address: 1110 12 AVE NE, STE 500 ; SEATTLE, WA, 98004 Contractor: Name: INTERIOR ELECTRIC INC Phone: (360) 863-8678 Address: 21428 167 AV SE , MONROE, WA, 98272 License No: INTEREI003CP Expiration Date: 2/17/2016 Lender: Name: Address: DESCRIPTION OF WORK: ELECTRICAL WORK FOR FUEL FACILITY EXPANTION WHICH INCLUDES POWER TO THREE DISPENSERS, RELOCATION OF SITE LIGHTING, AND UPGRADING OF UNDERGROUND STORAGE TANK TURBINES. Valuation of single family: $0.00 Valuation of mf/comm: $87,000.00 Type of Work: ADDITION Fees Collected: $1,893.38 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: itir4,c. /,T/wLr Date: 0 401//Y I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to theemconditionscoattached to this permit. Signature: 1 ChL�,t,IX / V J Date: J% 11/.20/ Print Name: P /.P ('a/v m, �h i m This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Electrical Permit No. Project No. Date Application Accepted: Date Application Expires: LLc— OI�PI 0� �4�II4 (For office use only) ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 451 Costco Drive Tenant Name: Costco Wholesale Corporation PROPERTY OWNER Name: Costco Wholesale Corporation Address: 999 Lake Drive City: Issaquah State: WA Zip: 98027 CONTACT PERSON — person receiving all project communication Name: Kendall Williams Address: 1110 12th Avenue NE, Suite 500 City: Bellevue State: WA Zip: 98004 Phone: (425) 463-1252 Fax: (425) 463-1725 Email: kendall.williams@mulvannyg2.com King Co Assessor's Tax No.: 3623049107 Suite Number: Floor: New Tenant: ❑ Yes ❑ .. No ELECTRICAL CONTRACTOR INFORMATION Company Name: Interior Electric Address: 21428 167th Avenue SE City: Monroe State: WA Zip: 98272 Phone: (360) 863-8678 Fax: Contr Reg No.: INTERE 1003CP Exp Date: 02/2016 Tukwila Business License No.; B-0995264 Valuation of Project (contractor's bid price): $ 87,000 Scope of Work (please provide detailed information): Electrical work for the fuel facility includes the addtion of three dispeensers, relocating existing site lighting, and upgrading existing underground storage tank turbines. Will service be altered? ❑ Yes EJ No Adding more than 50 amps? Yes ❑ No Type of Use: Type of work: ❑ New ® Addition ❑ Service Change ❑ Remodel ❑ Tenant Improvement 0 Low Voltage ❑ Generator ❑ Fire Alarm ❑ Telecommunication ❑ Temporary Service Property Served by: ET Puget Sound Energy ❑ Seattle City Light H:Wpplications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings $81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration $81.90 (no added/altered circuits) ❑ Service change with added/altered circuits $81.90 number of added circuits $11.55 ea ❑ Circuits added/altered without service change $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change $54.60 (6 or more circuits) $7.65 ea ❑ Meter/mast repair $68.25 ❑ Low voltage systems $59.85 (alarm, furnace thermostat) MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) $65.00 ❑ Temporary service (generator) $80.90 ❑ Manufactured/mobile home service $86.25 (excluding garage or outbuilding) ❑ Carnivals $80.60 Number of concessions $10.80 ea Each ride and generator truck $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR ELECTRICAL CONTRACTOR: Signature: � VGA �►...�—_.�� Date: /s't' 14 Print Name: Mostafa Ah chi Authorized Agent for Costco Wholesale Day Telephone: (425) 463-2000 Mailing Address: 1110 12th Ave NE, Suite 500 Bellevue WA 98004 City H:\Applications\Forms-Applications On Line\2014 Applications\Electrical Permit Application Revised 1-1-14.docx Revised: January 2014 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY PAID $1,529.27 EL14-0139 Address: 451 COSTCO DR Apn: 3623049107 $1,529.27 ELECTRICAL - $1,456.45 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $1,456.45 TECHNOLOGY FEE $72.82 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1703 R000.322 900 04.00 $72.82 $1,529.2.7 Date Paid: Friday, April 04, 2014 Paid By: MICHELLE MARVIN Pay Method: CREDIT CARD 03123C Printed: Friday, April 04, 2014 11:41 AM 1 of 1 SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID $364.11; $364.11 $364.11 $364.11 $364.11 PermitTRAK EL14-0139 Address: 451 COSTCO DR Apn: 3623049107 ELECTRICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R1271 R000.345.832.00.00 Date Paid: Tuesday, February 18, 2014 Paid By: COSTCO WHOLESALE Pay Method: CHECK 5765876 Printed: Tuesday, February 18, 2014 9:36 AM 1 of 1 SYSTEMS Inspector: INSPECTION RECORD Retain a copy with permit 0 INSPECTION N0. PERMIT NO. 1 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 tULfOI 3y Permit Inspection Request Line (206) 431-2451 Project: 1 i!o5�� C 5 Type of Inspection: -74/A.-- Address: tic, /J _ s r - , Dt• Date Called: Special Instructions: Date Wanted: 6 // I a.m.. p.m. Requester: Phone No: NApproved per applicable codes. OCorrections required prior to approval. I COMMENTS: ' I! ( ` _ - //I Y 51964JSt- -5 # 7 �.►o aV 0 r3 4110 7411 r7hik1v — Date: il 04 / )1'"4114\ r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: sr� 61, Type of Inspection: 'v Address: / 5/ 657� Date Called: Special Instructions: Date Wanted: 6 b(0 Requester: I Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: ) Il i Li -h- - 15136/5t-2-,5 a I ArlD g 2,- %}}L r\t-e,�-k(11€ Pr6ti D -0 CArdalki LAt(i TIrJ l Inspector: � h1h/f-lc REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: 012j/6/j (j 1 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670fINSPECTION RECORD 6400 Retain a copy with permit INSPECTION NO. PERMIT NO.' CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ( 5rc064'5 Type of Inspection: V� Address: /,_ Z��! (75i CO ( • Date Called: t �.- Special Instructions: Date Wanted: ' ! © a.m p.m. Requester: i 1 Phone No: ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: ) V0oVc0Jt i C , 001-5 f s c,--.J I D 3 Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RtCORD Retain a copy with permit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ^ c/-• � S 17..o f� C'-+,�'�1���G Type of Inspectio _ tr /U y `U,lp Icy Address: Date Called: Special Instructions: Date Wanted: t (.7 D m. p�rtf� Requester: ���� Phone No: Ii'i 7 3831- Approved per applicable codes. Corrections required prior to approval. COMMENTS: ik dIJ82.(A ad.)4 r ,41 J r fsLA-41)41 Iiipsowiff rf Inspector: iJ' Date: o(!03 �I REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTIONkRECORD Retain a copy with permit INSPECT ION NO. PERMIT NO. ! CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 tfro Project: 4 .0 57 LAD 6405 Type of lnspectiont 041)t4--(4.d th'ib Address: fi/ r. (05ft...-0 Date Called: Special Instructions: Date Wanted: m Requester: I Phone No: ElApproved per applicable codes. IJ Corrections required prior to approval. COMMENTS: r/ Iii fij��c�JiJD (vAIDJ1 r5 /5111AJD 4 1 inspector: 11 Date: I ' REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION_ RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 cad Project: /. 645 Type of Inspection:. ! Q /� J /6 Address: , 'i* (, SiC.olk- Date Called: Special Instructions: Date Wanted: cf 37 a.m: Requester: Phone No: DApproved per applicable codes. Corrections required prior to approval. COMMENTS: ?A 0 r -6,,,,Je6JJam$ Inspector: 5107/iti I i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit O[' 01 31 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection+ Address: Gf61,z51 co k` Date Called: Special Instructions: Date Wanted: q /a.m�, Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: <2 1/ F`o LA'S( &AID + i Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit TION NO. PERMIT. NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 api'v(39 Project: Ad '"s' ?�� Type of Mspection tea pk f V� Address: j�r��'" %� �/ 1 ) 1 t.; SICA) ice s Date Called: Special instructions: Date Wanted: am. y zZ Requester: (� &I Phone No: Kzg till 5s 2.._ QApproved per applicable codes.Corrections required prior to approval. COMMENTS: 1 a� s! 1. - - /Pcdk rifscat Ak 611.10Vir vt 5 c .,149 (Jtklitz te r Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite`100. Call to schedule reinspection. WHOLESALE January 2014 Re: Authorized Agent of Costco Wholesale To Whom It May Concern: This letter hereby authorizes Mostafa Ahanchi to act on behalf of the Construction Department of Costco Wholesale as Authorized Agent in regard to any Costco construction project in North America. He is authorized to sign all jurisdictional, service and utility related documents having to do with any Costco building or site under construction. Should you need any further information, please contact me at 425.313.8100. Sincerely,_ / Ali Mo Sen. eri Vice President of Construction 999 Lake Drive • Issaquah, WA 98027 • 425/313-8100 • www.costco.com PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL14-0139 DATE: 02/18/2014 PROJECT NAME: COSTCO GASOLINE SITE ADDRESS: 451 COSTCO DR X Original Plan Submittal Response to Correction Letter # Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: s92 Atti 345-‘14 Building Division Public Works Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 02/20/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 03/20/14 Approved with Conditions Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 INTERIOR ELECTRIC INC Page 1 of 2 .4 Washington State Department of Labor & industries INTERIOR ELECTRIC INC Owner or tradesperson MARVIN, WAYNE S Principals MARVIN, WAYNE S MARVIN, MICHELLE RMarvin, Michelle Doing business as INTERIOR ELECTRIC INC WA UBI No. 601 999 759 21428 167TH AVE SE MONROE, WA98272 360-863-8678 SNOHOMISH County Business type Corporation Governing persons MICHELLE RENE MARVIN WAYNE STEWARD MARVIN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. Meets current requirements. License specialties GENERAL License no. INTEREI003CP Effective — expiration 02/17/2000 — 02/17/2016 Designated administrator MARVIN, WAYNE S License type Electrical Administrator Bond No bonds during the previous 6 year period. Insurance No insurance accounts during the previous 6 year period. Savings (in lieu of bond) Savings account ID License Violations No license violations during the previous 6 year period. Active. Meets current requirements. License no. MARVIWS136RE $4,000.00 Effective date 02/15/2000 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601999759&LIC=INTEREI003CP&SAW= 04/04/2014 GILBARCO DISPENSER WIRE COLOR REFERENCE 1. BLACK #12: HOT TO A-2 (CD MODULE) & VARISTOR 2. GREEN #12: TO A-10 (GROUND) 3. WHITE #12: NEUTRAL TO A-13 (CD MODULE) & VARISTOR 4. RED #12: TO STP1/MTR1 5. BLUE #12: TO STP2/MTR2 6. YELLOW #12: STP3/MTR3 7. YELLOW #14: not used 8. PURPLE #14: not used 9. PINK #14: not used 10. BROWN #14: not used 11. #14: TO B-9 (CRIND TWO WIRE OUT (-)) BLACK >TWISTED PAIR NON SHIELDED 12. #14: TO B-19 (CRIND TWO WIRE IN (+)) WHITE NOTE: ALL WIRE TO BE THWN, OIL AND GAS RESISTANT NO EXCEPTIONS 13. #14: TO A-9 (PUMP TWO WIRE OUT (-)) 14. #14: TO A-19 (PUMP TWO WIRE IN (+)) BLACK TWISTED PAIR >NON SHIELDED RED PER CIVIL DRAWINGS COMPACTION PER CIVIL PLANS POWER AND CONTROL CONDUITS PER PLAN El 12" MIN NOTE: 1. PROVIDE PULL BOXES (SIZE PER CODE) FOR CONDUITS AS REQUIRED FOR EVERY 250' OR AFTER TOTAL OF 270 DEGREES OF BENDS. 2. PROVIDE SUFFICIENT ADDITIONAL LENGTH OF CONDUCTORS AT THE TERMINATION POINTS OF ALL CONDUITS FOR FINAL EQUIPMENT HOOKUP. 3. SUPPLY AND INSTALL ALL CONDUITS/CONDUCTORS AND A 25 LB. PULL CORD IN EACH SPARE/FUTURE CONDUIT. s� s� Trench Trench Detail NOT TO SCALE • 1 i LL RELOCATED VENT STACK AND PERMEATOR EXTERIOR CONDUIT SCHEDULE CONDUIT # SIZE CONDUIT PURPOSE CONDUIT FILL COMMENTS T 11 DISPENSER POWER 41112 THWN; (2) 1114 TWISTED PAIR & 11112 GND. (NEW) FROM DISPENSER 9/10 TO CONTROLLER ENCLOSURE 1" DISPENSER POWER 41112 THWN; (2) 1114 TWISTED PAIR & 11112 CND. (NEW) FROM DISPENSER 15/16 TO CONTROLLER ENCLOSURE 3/4" DISPENSER SENSOR (3) BELDEN CABLE #88760 (1) #12 GND (NEW) FROM DISPENSER 9/10 TO CONTROLLER ENCLOSURE 3/4" DISPENSER SENSOR (3) BELDEN CABLE #88760 (1) #12 GND (NEW) FROM DISPENSER 15/16 TO CONTROLLER ENCLOSURE 13 3/4" (E) TURBINE POWER 3#10 THWN & 1#10 GND (NEW) FROM TURBINE SUMP TO CONTROLLER ENCLOSURE (E) 3/4" ARID PERMEATOR POWER 3#12 THWN & 1#12 GND (NEW) FROM TURBINE SUMP TO CONTROLLER ENCLOSURE (E) 1" ARID PERMEATOR COMMUNICATION 25# PULL CORD FROM TURBINE SUMP TO CONTROLLER ENCLOSURE (E) RELOCATE VENT STACK AND PERMEATOR \\ EXIST NG f EXISTING TANK #3 UNLEADED PREMIUM LOCATE AND INTERCEPT EXISTING CONDUITS. PULL NEW WIRING PERMEATOR POWER PERMEATOR COMMUNICATION EXISTIN VEEDER RO T ALARM MONITO SYSTEM CONTROLLER ENCLOSURE 0 EXISTING ESO SEE T-5 FOR MATERIAL LIST EE- SCALE 1 "= 10'-0" O. i� Electrical Site Plan EXISTING TANK #2 UNLEADED REGULAR EXISTING TANK #1 UNLEADED REGULAR DISPENSER POWER. DISPENSER26 SENSOR DISPENSER POWER DISPENSER26 SENSOR DISPENSER POWER DISPENSER26 SENSOR 2 2 2 2 2 2 CANOPY ABOVE 3 i 3 NEW CANOPY EXPANSION n l� NEW DISPE \ )NEW ti3 3 EXISTING TANK #4 DITIVE 0 CaII Toll Free 1 (800) 922-1987 TWO WORKING DAYS BEFORE YOU DIG ■ 3 Q c Q EXISTING CANOPY ❑ EXISTING DISPENSER (-8) ❑ NiER I ri ❑ ❑ ❑ ❑ N PWW REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. OT4: Rsvisions will require a new plan submittal and may include additional plan review fees. FUEL POSITION NUMBERING: NOTE FUEL POSITION DECAL NUMBERS ARE PROVIDED BY OWNER AND INSTALLED BY START UP TECHNICIAN. START UP TECHNICIAN SHALL FOLLOW DISPENSER NUMBERING AS SHOWN ON PLANS. TANK FILLS CLASS 1, DIV 2 SEE NOTE #7 TANK TURBINES C A SS 1, DIV 2 EE NOTE #7 II ° )ISPENSER AREA CLASS 1, DIV 2 SEE NOTE #7 VENT AREA CLASS 1, DIV 2 SEE NOTE C 2 UNDERGROUND i �♦��♦1♦♦1♦�0♦•1 •'�♦�♦�704.' 4:14 .�♦i♦♦♦Ii �i1�♦♦i1♦i♦♦i'i11i1♦i Ii11♦♦i ,•1♦ ♦1,,4♦♦4 : ♦1♦♦1♦♦♦47... ♦440...= i♦�i♦.f4741 �♦0 Ili♦��♦i♦.i♦�i♦%� i A i'�i`•� • "♦♦i♦♦♦♦♦♦i! ►�►♦1♦♦1♦ ♦1 �♦�♦i♦�♦�1��� �1 ���►♦♦ 1. .♦♦�♦♦♦1 i ��.�♦1♦.*.♦�1♦♦♦•♦4•♦♦♦.40141� �♦o �1 �♦♦ .-,, 1♦♦♦♦♦ ;1 ♦♦♦♦♦♦♦'��i1 "" ►�1♦♦♦' ♦ ♦♦ 1► ♦1♦♦ ♦1♦1♦1 ♦1.1•♦1 �►�►4p.44 ♦ ♦• '♦♦♦♦it �►♦♦111.1♦Ii♦1♦i1♦Ii1 ►♦Ii�1i► ►-� ..- ♦ ♦1i ►� Ii1 ♦1♦Ii1 ♦Ii♦1♦♦l►��♦♦1♦ ►. sr� 4PI* .. • -•.*'. • �>• •♦♦ •11♦♦♦ •♦♦1 ♦, ♦ • :�►♦♦♦ ♦Ii1♦1 ♦ N '♦ ♦i1♦♦♦♦♦Ii1♦1♦1♦1♦1♦4*• ♦♦ 1♦b11♦♦1♦••#4".7. ♦►♦♦♦♦111 ♦♦♦♦1 ♦�► ;♦♦Il ♦•♦�I.•.*",4*-4 ♦ -• -- _ 4***•11♦♦1 ♦11♦i♦Ii♦1♦♦i♦lift" �1 i♦♦♦♦fir. • �♦1�1.1•QI4r♦1110 ► ►♦1♦♦1111♦1�111�♦���1♦ 1���1 r* ♦�♦I�•• • i ►� %:!���1♦ •♦1♦♦i:!i� ''1♦�i♦!i:!%!:♦i:!iSli9:♦i=!► ♦�I�V�I� ♦I 1♦ 1► � � I '►�In11♦ _ 1�.1►•_• _ C - ►7 •4•4 0 .. ♦1111 ♦►1♦ ►� I',Ite:.♦4�: J�♦`•r♦♦♦� --ic I4♦i•►I1♦.!•�/`♦%tett�1.�►♦►Ij:i , 4 INN VI, �/♦♦i�1 �1 7.4, ♦♦111 ``♦♦1♦♦1♦♦4' 0tp1♦11 ♦♦.,1♦11♦♦11♦1 ♦i1�i ► 4*4*1 •1j�1j' 1�' j r4.47 g.ik•ip%. ♦��.",e4♦i'�sp..�1i'�.0 �'%i'.1♦♦♦ .♦ N ♦ ♦111 ♦ �1 1, -t.•♦1 ••♦•♦ ♦11♦IIi♦1 �♦'► 400.. •..• . ► ''►11♦♦1♦1♦♦♦♦♦11♦♦ 40. ♦I, ♦1♦♦ •k•e.•... ♦♦♦ ♦♦♦��1♦. 0 i111► 4 4 .♦♦♦♦♦♦♦♦1♦♦♦♦1•♦!'♦♦♦14!1'i♦1♦1♦♦1•♦1♦♦1♦♦i♦♦i11♦Ii11♦•4!iO4 •• 1r�:74-T1r04 ����♦�♦4►-t-jA1=�4•-.w♦1�1,�l��0�•-♦•-♦•♦!•A%�AP;Vo1��PI!t�ti10�1i��' lti,kt�'" ..*4�i1i1' i.♦..,i►� ►►11• - • ♦♦♦♦♦�1�I ►♦ t...........*.♦1�♦♦♦1►�*.t.e •♦♦•����t•O#1♦1♦��11♦♦ ► t.4.♦♦♦♦1♦1♦♦♦1♦1.1♦l►�♦0 i�►l ►' ►♦11♦1♦11♦.4 • ♦♦1 t4♦♦ - ♦♦♦•♦♦♦♦♦1♦1*e�ll •♦� 40, �Aw•••-♦1♦1i•♦♦♦1i►N►1•♦♦1♦1♦1♦♦1♦♦♦♦♦41114114►♦♦♦:1 •♦1► 4 •• 1♦111♦••1 ♦Ai.♦♦♦ •♦1♦1♦1••1♦1♦1 •4F ♦1♦��j� ► '1•1.1♦•1♦♦i•♦♦♦♦IP �j ♦ 4.0*♦ ••♦♦ ♦Ij��♦4►♦ t ♦1 �• ��� 4 ♦♦�♦♦ •♦♦•V• ♦♦�♦4 r •• ♦1�♦♦• ♦♦ •�♦�♦•♦1•�♦ ♦1� �► '401 1•1�1144' 1► :1♦♦�11♦11♦♦I�i1♦♦1♦ 1♦1�� 1 �1♦11♦Ij11♦1♦11�Ij♦1♦11♦�♦���� 1�•111��11 !►�11 r•����ii !•:•••�i♦��♦i�i♦♦i�♦♦� i %�:,414i!♦:!i:!%lall i �i ��►;�i♦1 ►111♦♦111'1� i I . i ►1♦�'♦i e f 0 r :♦ .�i1� 1:!it4.,-r I0rod'1�!♦1♦:. ♦.�1i♦1♦4* ►� !*3 11e►l!♦i�♦iPk*,��!.%iwli'�1%%4' �4�i�1i�♦1♦ii.4, i1 • 1 I ►4 ♦i i 1'i.n•♦Q♦�1'11♦11 r1♦1♦ ►♦►\1♦♦♦1,♦444.i►a.41 ► !•♦1♦itl,14 ♦1,♦41,4 ►♦1��1♦r� 1'';1♦♦1♦1♦*♦I♦1.11♦1•1• ♦•,•♦1♦4wilp ***•♦♦11♦'I`•••♦♦1♦♦♦1�1'f♦�♦�`•�� TANKS Hzardous Location I.D. N.E.C. HAZARDOUS AREA NOTES TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK - FILL OPENING) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN A HORIZONTAL RADIUS OF 10 FEET • FROM A LOOSE FILL CONNECTION AND WITHIN A .HORIZONTAL RADIUS OF 5 FEET FROM A TIGHT FILL CONNECTION. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (UNDERGROUND TANK - VENT -DISCHARGING UPWARD) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: WITHIN 5 FEET OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: SPACE BETWEEN 5 FEET AND 10 FEET OF OPEN END OF VENT, EXTENDING IN ALL DIRECTIONS. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (REMOTE PUMP - OUTDOOR) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: ANY PIT BOX,SP ACE S ACE BELOW GRADE LEVEL IF ANY PART IS WITHIN A HORIZONTAL DISTANCE OF 10 FT. FROM ANY EDGE OF PUMP. EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: WITHIN 3 FEET OF ANY EDGE OF PUMP, EXTENDING IN ALL DIRECTIONS. ALSO UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 10 FEET HORIZONTALLY FROM ANY EDGE OF PUMP. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - PITS) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: ANY PIT, BOX, OR SPACE BELOW GRADE LEVEL, ANY PART OF WHICH IS WITHIN THE DIVISION 1 OR 2 CLASSIFIED LOCATION. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) EXTENT OF CLASS 1, GROUP D, DIVISION 1 LOCATION: SPACE CLASSIFICATION INSIDE THE DISPENSER ENCLOSURE IS COVERED IN ANSI/UL 87, "POWER OPERATED DISPENSING DEVICES FOR PETROLEUM PRODUCTS." TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - DISPENSER) EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: WITHIN 18 INCHES HORIZONTALLY IN ALL DIRECTIONS EXTENDING TO GRADE FROM (1) THE DISPENSER ENCLOSURE OR (2) THAT PORTION OF THE DISPENSER ENCLOSURE CONTAINING LIQUID HANDLING COMPONENTS. TYPICAL N.E.C. ARTICLE 514 CLASS 1 LOCATION (DISPENSING DEVICE - OUTDOOR). EXTENT OF CLASS 1, GROUP D, DIVISION 2 LOCATION: UP TO 18 INCHES ABOVE GRADE LEVEL WITHIN 20 FEET HORIZONTALLY OF ANY EDGE OF ENCLOSURE. SERVICE DATA SERVICE VOLTAGE: 3 PH 120/208V, 4W LOAD DATA: CONNECTED 44.0 KVA, ESTIMATED DEMAND 45.4 KVA SERVICE CONDUCTORS 4#3/0 THWN & 1#4 GND. METERING: PER UTILITY TYPE: UNDERGROUND BILLING INFORMATION: COSTCO WHOLESALE 999 LAKE DRIVE ISSAQUAH, WA 98027 ATTN: Deanna Hughes UTILITY CONFLICT NOTE: CAUTION: THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THE LOCATION, DIMENSION, AND DEPTH OF ALL EXISTING UTILITIES WHETHER SHOWN ON THESE PLANS OR NOT BY POT HOLING THE UTILITIES AND SURVEYING THE HORIZONTAL AND VERTICAL LOCATION PRIOR TO CONSTRUCTION. THIS SHALL INCLUDE CALLING UTILITY LOCATE ( 1 (800) 922-1987 AND THEN POT HOLING ALL OF THE EXISTING UTILITIES AT LOCATIONS OF NEW UTILITY CROSSINGS TO PHYSICALLY VERIFY WHETHER OR NOT CONFLICTS EXIST. LOCATIONS OF SAID UTILITIES AS SHOWN ON THESE PLANS ARE BASED UPON THE UNVERIFIED PUBLIC INFORMATION AND ARE SUBJECT TO VARIATION. IF CONFLICTS SHOULD OCCUR, THE CONTRACTOR SHALL CONSULT BARGHAUSEN CONSULTING ENGINEERS, INC. TO RESOLVE ALL PROBLEMS PRIOR TO PROCEEDING WITH CONSTRUCTION. GENERAL NOTES SEE MATERIALS LIST (T-5) FOR DESCRIPTION ON EQUIPMENT USED IN THIS CONSTRUCTION. 2. ROUTING SHOWN ARE SCHEMATIC, FINAL LOCATIONS SHALL BE SHOWN ON AS -BUILT DRAWINGS. 3. ALL EQUIPMENT SHALL BE INSTALLED AS PER MANUFACTURER'S AND/OR OWNERS GUIDELINES, WHICHEVER IS MORE STRINGENT. 4. FUNCTIONS OF THE CONTINUOUS MONITORING: - MONITORING OF ALL ANNULAR SPACES. - MONITORING OF ALL PRODUCT PIPING AND FILL SUMPS. - PROVIDE .1 GPH PRESSURE LINE LEAK DETECTION (PLLD) OF PRODUCT LINES. - PROVIDE CONTINUOUS TANK LEVEL MONITORING. - MONITORING OF ALL DISPENSER SUMPS. THE CONTINUOUS MONITORING DEVICE PROVIDE POSITIVE SHUTDOWN OF TURBINES AND DISPENSERS AUTOMATICALLY IN THE EVENT OF A LIQUID RELEASE AND MANUALLY THROUGH THE ESO SWITCH LOCATED ON THE CONTROLLER ENCLOSURE AND REMOTE ESO SWITCH AS INDICATED ON SITE PLAN. 5. ALL WIRES ENTERING CONTROL PANELS, MAIN PANELS, AND SUB PANELS SHALL BE MARKED WITH PHASE TAPE CODING AS FOLLOWS: "A" PHASE = BLACK "B" PHASE = RED "C" PHASE = BLUE 6. ALL CONDUCTORS SHALL BE CONTINUOUS (WITH NO SPLICES) STRANDED COPPER WITH 75°C THWN INSULATION, OIL AND GAS RESISTANT. PERMIT RELEASE CD 0 m .y Q) cc 1` Q U 0 W 0 Z Z > Q cc z0 0 c0 1= 0 u)0 J 0 o 0 W J W TUKWILA, WA 91406 t0 0 J 0 LL W Z J 0 co a 0 0) 0 0 7. A SEAL OFF MUST BE INSTALLED PRIOR TO ENTERING AND LEAVING A CLASSIFIED AREA. CONDUITS FIRST EMERGENCE FROM BELOW GRADE MUST BE CONNECTED TO A SEAL -OFF. 8. ALL CONDUITS SHALL HAVE INSULATED GROUNDING BUSHINGS INSTALLED AND TIED TOGETHER W/ #6 BARE COPPER WIRE. BOND ALL INSULATED GROUNDING BUSHINGS AND GUTTER BOX BACK TO POWER CENTER GROUND. 9. ALL INSTALLATIONS SHALL BE PER N.E.C., ARTICLE 514. 10. ALL EQUIPMENT SHALL BE U.L. APPROVED AND LISTED BY A NATIONALLY RECOGNIZED TESTING LABORATORY. 11. ALL EQUIPMENT EXPOSED TO WEATHER SHALL BE LISTED FOR EXTERIOR USE. 12. USE RIGID SCHEDULE 40 PVC CONDUIT BELOW GRADE BETWEEN PLASTI-BOND ROBROY PVC COATED RIGID METALLIC TRANSITION. PLASTI-BOND ROBROY PVC COATED RIGID METALLIC SHALL BE USED FOR TURBINE POWER ENTIRE RUN (NO EXCEPTIONS). KEYNOTES 1 2 3 4 PROVIDE 90 DEGREE FITTINGS (SUCH AS CROUSE HINDS "LB") FOR PENETRATION INTO CONTROLLER ENCLOSURE. ALL ELECTRICAL JUNCTION BOXES IN TANK SUMPS AND UNDER DISPENSER CONTAINMENT AREA SHALL BE EXPLOSION PROOF WITH SEAL -OFF ENTERING AND LEAVING. SEAL -OFFS TO BE A MINIMUM OF 6" ABOVE THE HIGHEST PENETRATION FOR TESTING PURPOSES. ALL CONDUIT RUN ENTERING OR LEAVING A TANK AND VENT SUMPS AND DISPENSER TRANSITIONS SHALL BE ROBROY PVC COATED RIGID METAL CONDUIT NO EXCEPTIONS. EXTEND EXISTING HEAT TAPE SYSTEM TO NEW CANOPY DOWNSPOUTS AND GUTTERS. CONTACT MANUFACTURE AT (778) 837-4542 FOR INSTALLATION GUIDELINES. PROVIDE NEW PLLD ON TURBINE #2. AS -BUILT SHOW AN ADDITIONAL BELDEN CABLE, HOWEVER CONTRACTOR SHALL" VERIFY IF ONE EXIST. IF NO CABLE EXIST CONTRACTOR SHALL PULL ALL NEW CABLES. A L" COPY Re1i'mit®.SW ° 13? Plan review approval is subject to errors and omissions. «1,a;., ';;;'a of construction documents does not authorize F,o ation of any adopted code or ordinance. Receipt of approved Field Copy and ' • wledged: By Data SEPARATE PERMIT REQUIRED FOR: Mechanical [I Electrical entumbing [was Piping City of Tukwila BUILDING DIVISION P HV LV VR E.S.O. E.D.P. C F.F. LEGEND Al/q/26 City Of Ibkwila BUILDING DIVISION EXISTING UNDERGROUND CONDUIT UNDERGROUND ELECTRICAL SERVICE CONDUIT UNDERGROUND TELEPHONE SERVICE CONDUIT EXPOSED CONDUIT UNDERGROUND CONDUIT CLASS I HAZARDOUS AREA (PER NEC) EXPLOSION PROOF SEAL REVIEWED FOR ,F-PLIANCE WITH NFPA 70 - NEC FEB 19 2014 City of Tukwila BUILDING DIVISION INDICATES DISPENSER NUMBERING AND POSITION HIGH VOLTAGE LOW VOLTAGE VEEDER- ROOT EMERGENCY SHUT-OFF ELECTRICAL DISTRIBUTION PANEL CONDUIT � I FINISHED FLOOR COSTCO SITE �. ANDOVER PARK EAST �- CO SOUTHCENTER PKWY NOT TO SCALE ALLEY HIGHWAY Irll IXISTNG REGIONAL OPNCAL FACILITY NI COSTCO DRIVE L RECEIVED CITY OF TUKWILA FEB 18 2014 PERMIT CENTER 0 1, poirlprprrricittn i I I I I IH6d�' 0111 1111111V 4K c--IIII9 IXIS IN0 SUITE 150 SITE MASTER RELEASE 0 0 0 0 0 00 0 NI 00 0 co 00 00 • • (1) LLI Luz o Date/Time:2/3/20 0 00 CO 0 0 ro CT 0 ITD 0 00 co cn 0 E-1 S LE SC LE „ -0 ' 2020�-0" VICINITY MAP LOCATOR MAP NOT TO SCALE CONTRACTOR SHALL VERIFY THERE IS ROOM AVAILABLE IN THE EXISTING CONTROLLER ENCLOSURE FOR NEW ADDITIVE EQUIPMENT. ALERT ARCHITECT IMMEDIATELY IF THERE IS NO ROOM. LEFT WALL ELEVATION SCALE: NTS REAR WALL ELEVATION SCALE: NTS C RIGHT WALL ELEVATION E-Z SCALE: NTS (D FRONT WALL ELEVATION SCALE: NTS FIBER/PHONE TERMINATION BOX O 0 • 0 EXISTING GILBARCO D-BOX SEE NOTE #7' (E) MAG VFC UNL B EXISTING WIREWAY 2� MAG 71 PREM C (E) STP DH I A26( E) 0 T EXISTING ALLIED ANDI BOX (E) GSM 0 000 EXISTING 26 21 23 WIREWAY (E) GSM 00 00 ( E) NEW GILBARCO D-BOX 67 66 A26 (E) UPS EXISTING PANEL SEE NOTE #7 23 (E) TIMER (E) CBS STP ADD EXISTING PANEL "1 A" n P IA V T EXISTING ADDITIVE CONTROLLER PANEL EXISTING VEEDER ROOT 23 40) 00 00 (E) EXISTING ARID PERMEATOR PANEL EXISTING LOW VOLTAGE WIRING DISCONNECT (E) HV 23 I.S. HV EXISTING WIREWAY EXISTING WIREWAY 0 O 0 O 0 (E) EXISTING WIREWAY FINISHED FLOOR 1/- / / / / EXISTING A/C UNIT (E) (E) INTERIOR ROUTING IN CONTROLLER --- ENCLOSURE PER ELEVATION EXISTING WIREWAY (I.S. OR 120V) FINISHED FLOOR EXTERIOR -SEAL AROUND CONDUIT PENETRATIONS PROVIDE 90 DEGREE FITTINGS (SUCH AS CROUSE HINDS "LB") FOR PENETRATION INTO CONTROLLER ENCLOSURE. HEIGHT TO BE FIELD DETERMINED CONDUIT SIZE AS NOTED PVC COATED RGS TRANSITION PENETRATION DETAIL SCALE: NTS FINISHED GRADE L• CONDUIT RUN SCHEMATIC WITHIN CONTROLLER ENCLOSURE SCALE: NTS SIDE WALL ELEVATION SCALE: NTS NOTE: ENCLOSURE LAYOUT SHOWN IS TYPICAL. SEE SHEET El FOR ACTUAL CONTROLLER ENCLOSURE ORIENTATION. SEE NOTE #8 © O 44 44 00 J SEALOF (T(P.) EXTERIOR ELEVATION SCALE: NTS SEE NOTE # RELOCATE INTERCEPT EXISTING ARID CONDUITS (SEE E-1 FOR RMEATOR ESTIMATED LOCATION. PULL NEW WIRING AND PULL CORD VENT STACK TURBINE END 13 WIRING LEGEND RELOCATE VENT STACK SEALOFF (TYP.) RELOCATED VENT STACK POWER CONDUIT POWER & DATA CONDUIT CAMERA/COMM. CONDUIT INTRINSICALLY SAFE CONDUIT INDICATES ITEM ON MATERIALS LIST SEE DWG. T-5 EXTERIOR CONDUIT SCHEDULE CONDUIT CONDUIT PURPOSE CONDUIT FILL COMMENTS # SIZE 01 1" DISPENSER POWER 41112 THWN; (2) #14 TWISTED PAIR & 1#12 GND. (NEW) FROM DISPENSER 9/10 TO CONTROLLER ENCLOSURE 20 1" DISPENSER POWER 41112 THWN; (2) 1114 TWISTED PAIR & 1#12 GND. (NEW) FROM DISPENSER 15/16 TO CONTROLLER ENCLOSURE 3/4" DISPENSER SENSOR (3) BELDEN CABLE #88760 (1) #12 GND (NEW) FROM DISPENSER 9/10 TO CONTROLLER ENCLOSURE © 3/4" DISPENSER SENSOR (3) BELDEN CABLE #88760 (1) #12 GND (NEW) FROM DISPENSER 15/16 TO CONTROLLER ENCLOSURE 13 3/4" (E) TURBINE POWER 3#10 THWN & 1#10 GND (NEW) FROM TURBINE SUMP TO CONTROLLER ENCLOSURE (E) 14 3/4" ARID PERMEATOR POWER 3#12 THWN & 1#12 GND (NEW) FROM TURBINE SUMP TO CONTROLLER ENCLOSURE (E) 15 1" ARID PERMEATOR COMMUNICATION 25# PULL CORD FROM TURBINE SUMP TO CONTROLLER ENCLOSURE (E) INTERIOR CONDUIT SCHEDULE CONDUIT CONDUIT PURPOSE CONDUIT FILL COMMENTS # SIZE ® 1" DISPENSER CONTROL 41112 THWN & 11112 GND. (NEW) FROM WIREWAY TO TURBINE CONTROLLERS (UNL & PREM) ® 1" DISPENSER POWER 41112 THWN & 2112 GND (NEW) FROM WIREWAY TO PANEL "C" © 1" DISPENSER CRIND AND DATA (4) 21114 TWISTED PAIR & 1112 GND. (NEW) FROM WIREWAY TO D-BOX THRU DATA DISCONNECT ® 1" DISPENSER MONITORING (6) BELDEN CABLES 188760 & 11112 GND (NEW) FROM WIREWAY TO I.S. SIDE OF VEEDER-ROOT 8 1" DISPENSER DATA DISCONNECT POWER 2112 & 1#12 GND (NEW) FROM ELECTRICAL PANEL TO DATA DISCONNECT RECEPTACLE SHEET NOTES 1 ROUTE CONDUIT TO EQUIPMENT AS INDICATED ON SHEET E-1 AND E-2. 2. ROUTE CONDUIT AND CONDUCTORS TO EXTERIOR OF CONTROLLER ENCLOSURE WALL AS INDICATED ON THIS SHEET. PAINT TO MATCH CONTROLLER ENCLOSURE. 3 FUNCTIONS OF THE CONTINUOUS MONITORING: - MONITORING OF ALL ANNULAR SPACES. - MONITORING OF ALL PRODUCT PIPING SUMPS. - PROVIDE .1 GPH PRESSURE LINE LEAK DETECTION (PLLD) OF GASOLINE PRODUCT LINES. - PROVIDE CONTINUOUS TANK LEVEL MONITORING. -DISPENSER SUMP MONITORING. THE CONTINUOUS MONITORING DEVICE SHALL PROVIDE POSITIVE SHUTDOWN OF TURBINES AND DISPENSERS AUTOMATICALLY IN THE EVENT OF A LIQUID RELEASE AND MANUALLY THROUGH I HE ESO SWITCH LOCATED ON THE CONTROLLER ENCLOSURE AND REMOTE ESO SWITCH AS INDICATED ON SITE PLAN. 4. ALL WIRES ENTERING CONTROL PANELS, MAIN PANELS, AND SUB PANELS SHALL BE MARKED WITH PHASE TAPE CODING AS FOLLOWS: "A" PHASE = BLACK "B" PHASE = RED "C" PHASE = BLUE 5. WALL MOUNTED EQUIPMENT LOCATIONS ARE FIXED AS SHOWN REGARDLESS OF CONTROLLER ORIENTATION. G.C. SHALL NOT MOUNT EQUIPMENT OTHER THAT WHAT IS SHOWN. 6. ALL CONDUIT BETWEEN WIREWAYS AND ELECTRICAL DEVICES SHALL BE EMT OR RIGID GALVANIZED STEEL. NO EXCEPTIONS. 7. CONTRACTOR SHALL REMOVE EXISTING DISPENSER SURGE PROTECTION PANEL AND INSTALL NEW SURGE PROTECTION AND DISPENSER DATA DISCONNECT PANEL IN THE SAME LOCATION. 8. PROVIDE 90 DEGREE FITTINGS (SUCH AS CROUSE HINDS "LB") FOR PENETRATION INTO CONTROLLER ENCLOSURE. 9. PROVIDE NEW PLLD ON TURBINE #2. AS -BUILT SHOW AN ADDITIONAL BELDEN CABLE, HOWEVER CONTRACTOR SHALL VERIFY IF ONE EXIST. IF NO CABLE EXIST CONTRACTOR SHALL PULL ALL NEW CABLES. ALL WIRE PULLS BY G.C. UNLESS OTHERWISE NOTED CONDUIT LEGEND Is WHERE ALLOWED PER JURISDICTION, USE RIGID SCHEDULE 40 PVC CONDUIT BETWEEN PLASTI-BOND ROBROY PVC COATED RIGID METALLIC CONDUIT AND THE PLASTI-BOND ROBROY PVC COATED RIGID METALLIC TRANSITION. PERMIT RELEASE 0 CO 0 N 0. Y U a. 0 0 0 ELECTRICAL CONNECTION DIAGRAM 400 COSTCO DRIVE 0 I— c0 0 —J V LL W J 0 co 0 0 U co 0 0 REVIEWED .FOR CO PLIANCE WITH NFPA 70 - NEC FEB 19 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 18 2014 PERMIT CENTER W FN CV CO> oo0 J Cr 0 Q O__I3 w g O w U O LL MASTER RELEASE 0 0 c 0 N 00 0 > Designed OV/RGF 0 X 0 0 0 co 0 a> 0 18215 72ND AVENUE SOUTH N p N CO 0 I N N X CO N CO Job Number 000 00 N CV w O 0 00 0 0 4) U PANEL 1 MAIN/GENERAL VOLTAGE: 120/208 VOLT-30, 4-WIRE BUSS: 225A BREAKER RATED: 10,000 A.I.C. MAIN BRKR: M.L.O. SPACES: 42 * LISTED FOR SERIES COMBINATION WITH CURRENT LIMITING MAIN FUSE. DESCRIPTION LOAD BREAKER PHASE A B C NOTES LCL TO UTILITY SERVICE BY POWER COMPANY CIRCUIT # LEFT SIDE (ODD CIRCUITS) 1 3 5 7 9 11 13 15 17 19 SUB FEED TO PANEL 1A SUB FEED TO PANEL 1A CANOPY LIGHTS SPACE CANOPY LIGHTS CANOPY LIGHTS UPS RECEPTACLE CANOPY LIGHTS CCTV SPACE 11760 0 930 0 930 930 1440 620 360 0 100-2 100-2 20-1 FILLER 20-1 20-1 20-1 20-1 20-1 FILLER 11760 0 1440 0 0 930 620 930 930 360 Y Y Y Y 21 FASCIA LIGHT 240 20-1 240 Y 23 25 FASCIA LIGHT 120 20-1 120 EXISTING UTILITY VAULT OR POLE BY POWER COMPANY -\ Y EXISTING 3/4" x 10' COPPER CLAD STEEL 27 ADDITIVE TURBINE 960 20-2 960 29 ADDITIVE TURBINE 960 20-2 960 31 FE PETRO IST UNL 1 FE PETRO IST UNL 1 2400 30-3 2400 33 35 FE PETRO IST UNL 1 FE PETRO IST UNL 1 FE PETRO IST UNL 1 2400 2400 30-3 30-3 2400 2400 37 39 FE PETRO IST SUP #3 FE PETRO IST SUP #3 FE PETRO IST SUP #3 RIGHT SIDE (EVEN CIRCUITS) 41 2 SPACE 960 960 960 0 20-3 20-3 20-3 FILLER 960 0 960 960 4 CONTROLLER ENCLOSURE LIGHTS 720 20-1 720 6 8 CONTROLLER ENCLOSURE AC/HEAT SPACE 2500 0 20-2 FILLER 0 1500 10 12 QUAD RECEPT. - GENERAL USE TIME CLOCK POWER 864 180 20-1 15-1 864 180 14 SPACE 0 FILLER 0 16 CAMERA RADIO BOX 180 20-1 180 18 CANOPY CONTACTOR 180 20-1 180 20 SPACE 0 FILLER 0 22 SPACE 0 FILLER 0 24 SPACE 0 FILLER 0 26 DATA DISCONNECT RECEPTACLE 960 20-1 960 28 SPARE 960 20-1 960 30 SPACE 0 FILLER 0 32 FE PETRO IST UNL 2 FE PETRO IST UNL 2 2400 30-3 2400 34 36 FE PETRO IST UNL 2 FE PETRO IST UNL 2 FE PETRO IST UNL 2 2400 2400 30-3 30-3 2400 2400 38 ARID PERMEATOR 960 20-3 960 40 ARID PERMEATOR 960 20-3 960 42 ARID PERMEATOR 960 20-3 960 NOTE: ALL LOADS ARE EXISTING WITH THE EXCEPTION OF CIRCUITS A26 AND A28. BOTH ADDITIVE LOADS SHALL BE WIRED THRU NEW ESO CONTACTORS. CONTRACTOR TO FIELD DETERMINE WIRING SUCH THAT ADDITIVE LOADS ARE TIED INTO EXSITING EMERGENCY STOP SYSTEM TOTAL VA 20800 12194 11880 LCL 0 1790 4744 PLUS 25% 0 448 1186 TOTAL VA 20800 12642 13066 AMP PER P 174.0 105.4 108.9 PANEL LOAD 126.0 PANEL 1-A DISPENSERS/ELECTRONICS VOLTAGE: 120/208 VOLT-10, 3-WIRE BUSS: 100A MAIN BRKR FEED FROM -A- BREAKER RATED: 10,000 A.I.C. SPACES: 30 ACTUAL A.IC. BELOW 4,000 CIRCUIT # DESCRIPTION LOAD BREAKER PHASE A B NOTES LCL LEFT SIDE (ODD CIRCUITS) 1 IG RECEPTACLE 360 20-1 360 3 SPACE 0 FILLER 5 DISPENSER #1/2 960 20-1 960 GROUND ROD. EXISTING 2" C, (4) #3/O THWN C.U. + (1) #4 C.U. E.G. EXISTING NEMA 3R, 200A, METER SOCKET MOUNT ON EXTERIOR WALL OF CONTROLLER ENCLOSURE EUSERC COMPLIANCE 65,000 AIC SQ D CAT NO. UTH7213T P 2" C, (4) #3/0 THWN <5' B E-3 (4) #4 GND. EXISTING (1)-3" UNDERGROUND PVC CONDUIT (SCHEDULE 80) EXISTING UTILITY PAD MOUNT TRANSFORMER WITH CONCRETE PAD EXISTING (1) - #4 COPPER GROUND WIRE. 2" C, (4) #3EXISTING /0 THWN C.U. + (1) #4 E.G. EXISTING NEMA 3R, 200A, 200A FUSE (TYPE KTN-R-200) SERVICE DISCONNECT SWITCH MOUNTED ON WALL OF CONTROLLER ENCLOSURE SQ D CAT NO. D324- NR- B EXISTING CONCRETE ENCASED \ GROUNDING ELECTRODE. NEUT -1- 42 SPC 120/208 LUGS ONLY 0 SYSTEM GND. SURGE GND. ISOLATED GND. CONNECTED LOAD = 46.5 KVA -1.A- 30 SPC 120/208 SUB FEED / EXISTING �% CONTROLLER ENCLOSURE NOTE: CONTRACTOR FIELD VERIFY INCOMING CONDUCTOR SIZE IS 4#3/0 THWN CU & 1#4 GROUND AND FUSE SIZE IS 200AMP IN THE EXISTING DISCONNECT SWITCH iF NOT THE CONTRACTOR SHALL PROVIDE: (1)FUSE SIZE OF 200AMP (BUSSMANN LIMITRON KTN-R) INCOMING WIRE FROM TRANSFORMER TO PANEL IN EXISTING CONDUIT SHALL BE 4#3/0 THWN CU & 1#4 GROUND (3) #3 THWN C.U. (1) #8 GND C.U. Existing Single Line Diagram NOT TO SCALE 7 SWT NEUTRAL 9 11 13 DISPENSER #5/6 SWT NEUTRAL DISPENSER #9/10 960 20-1 960 960 20-1 960 15 SWT NEUTRAL 17 DISPENSER # 13/ 14 960 20-1 960 19 SWT NEUTRAL 21 23 DISPENSER #19/20 SWT NEUTRAL 960 20-1 960 25 DISP. DATA DISCONNECTS 360 20-1 360 27 SPACE 0 FILLER 29 GENERAL RECEPT 360 20-1 360 RIGHT SIDE (EVEN CIRCUITS) 2 4 VEEDER ROOT SPACE 360 0 20-1 FILLER 360 6 DISPENSER #3/4 960 20-1 960 8 SWT NEUTRAL 10 DISPENSER #7/8 960 20-1 960 12 SWT NEUTRAL 14 16 DISPENSER # 1 1 /12 SWT NEUTRAL 960 20-1 960 18 20 DISPENSER #15/16 SWT NEUTRAL 960 20-1 960 22 PLLD 360 20-1 360 24 SPACE 0 FILLER 26 28 DISPENSER #17/18 SWT NEUTRAL 960 20-1 960 30 IG RECEPTACLE 0 20-1 360 NOTE: TOTAL VA 11760 0 LCL 0 0 PLUS 25% 0 0 TOTAL VA 11760 0 AMP PER P 98.0 0 PANEL LOAD 56.5 A E-3 Existing Panel Schedule NOT TO SCALE A-23 NEW FASCIA SIGN LIGHT.(70) EXTEND CONDUIT AND WIRES TO NEW LOCATION CANOPY LIGHT FIXTURE(2) 6-NEW FIXTURES NOTES: (3) NEW CAMERAS SHALL BE INSTALLED USING EXISTING INFRASTRUCTURE BY OTHERS. CONDUITS BY CONTRACTOR. INSTALL NEW CANOPY LIGHTING USING EXISTING CIRCUITS AT THE CANOPY. WIRE LIGHTING WITH CIRCUITS AS SHOWN CANOPY LIGHT FIXTURE 16-REPLACED FIXTURES 62 NEW CANOPY AND® LIGHTS A-21 70 NEW FASCIA SIGN LIGHT. REPLACE EXISTING LIGHT A-15 /// /// A-15 A-15 A-11 x A-11 /// /1/ EXISTING ► CANOPY AND NEW LIGHTS A-11 /// NEW CAMERA A-15 A-11 ❑ n REMOVE EXISTING CANOPY FASCIA SIGN LIGHT A-9 x A-11 -9 X A-9 A-5 A-5 0 /1/ /// /// /// /// 63 (NEW CAMERA A-11 A-9 A-9 -5 3>NEW CAMERA A-9 A 5 A-5 /// /// A-5 A-21 70 NEW FASCIA SIGN LIGHT. EXTEND CONDUIT AND WIRES TO NEW LOCATION LUMINAIRE SCHEDULE SYMBOL QTY ARRANGEMENT LUMENS LLF DESCRIPTION INPUT WATTS 16 SINGLE 13594 1.000 MODEL NO. CRSK-SC-LED-64-HO-CW-UE 155 Canopy Lighting Plan REVIEWED FOR PLIANCE WITH NFPA 70 - NEC Citlf of Tukwila BUILDING DIV'S!, PERMIT RELEASE CD CD CO RECEIVED CITY OF TUKWILA CO CC 0 igt 0 >- 0 0 0 0 cn 0 0 _I pit 0 0 0) 0 0 gi MASTER RELEASE 0 0 0 Designed OV RGF CD 0 0 cia 0 2 18215 72ND AVENUE SOUTH N CO CO LLI 00 CO cc FEB 1 8 2014 PERMIT CENTER Job Number co oo AC LINE AC NEUTRAL CHASSIS GROUND BARRIER GROUND DOW AREA \TR \ S I CALLY SAFF A EA O �� ® II 35ni 16 SPARE 8 SPARE 15 SPARE 7 SPARE SPARE 14 PRESSURE I1 PLLD SUMPS MODULE T2 3T4T5 6-1 + I T I T I T I T I T MAXIMUM SENSOR OUTPUT RATING 15 VOC 15 AMP XMIT 6 I°J°I°1°I°I°I°1°I°I°I°I° 000000000000 TURBINE PRESSURE LINE LEAK INTERFACE 13 SPARE 5 SPARE SPARE 12 I + 1-I +2 -I + 3_ + 4 -I +5 -I +6 -1 +7 -1 +8 -I TANK & SENSORS MAXIMUM SENSOR OUTPUT RATING 15 VOC 15 AMP SENSOR 4 (. • • • • • • • • • • • • • • • 0000 000 0 0000 0000 SUMPS DISPENSER INTERSTITIAL SENSOR INTERFACE MODULE 0 SPARE(4. 11 TANK & SENSORS MAXIMUM SENSOR OUTPUT RATING 15 VOC 15 AMP FE1 -r+2-F+3-FE4 T+5F+6--+77-+8- SENSOR 3 • • • • • • • • • • • • • • •) 0000 000 0 0000 0000 SUMPS DISPENSER INTERSTITIAL SENSOR INTERFACE MODULE 10 1- UNL. #1 2 UNL.i 2 3- PREM. PI - PUMP PR -PUMP LI - LINE PO -PUMP INPUT SIGNAL RETURN (NEUTRAL) POWER INPUT OUTPUT CONTROL SENSOR 1 2 3 4 5 6 7 8 1 + -1 + -I -I { -1 + -I + -1 -1 + -I TANK & SENSORS PI PR LI POI PI PR LI PO I PI PR LI POI MAXIMUM SENSOR OUTPUT RATING 15 VOC 15 AMP 1. 1 • • • • • I • • 1 • • • • 1 • • • • 2 (• • • • • • • • • • • • • • • •) 0000eeeoe000eeeoO FRGAYCRANcS 120 VAC 24 MAX. 00 (2)0 0 0(2) 0 0000 00(2)0 SUMPS ANNULAR PRESSURE LINE LEAK CONTROLLER MODULE INTERSTITIAL SENSOR INTERFACE MODULE 9 4-RELAY OUTPUT MODULE 4�, c Nc No c I RELAY TO EXTERNAL DEVICE PROBE TANK GAUGES MODULE PROBE 1 - 1 1 2 3 4 OUTPUT MAXIMUMSENSOR RATING 15 VOC 15 AMP 1 Nc1 No c Nc No 2 c I N NC o T-F -��- -� -� RELAY RATINGS FROM C CONTACTS 120 VAC, 2A MAX OR 24 VOC, 2A MAX • • • I • 1 • • • • I • I • 1 • I • (• I • • • • • • • 0 0 0 0 0 0 0 0 0 0 0 0 LEVEL PROBE INTERFACE NOTE: THE SCOPE OF WORK ON THE VEEDER ROOT SYSTEM IS TO ADD TWO DISPENSER SENSORS. Veeder Root Console DOW-R AREA GROUND 0 �j. 16 MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 4 8 15 MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 4 8 1A MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 4 8 13 MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 4 8 12 MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 8 11 MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 4 8 ,- 1 U MODULE TYPE: PLLD CONTROLLER MODULE POSITION RECORD: 1 REG. UNLEADED #1 5 2 REG. UNLEADED # 3 PREM. UNLEADED #1 7 NEW 4 8 9 MODULE TYPE: 4-RELAY OUTPUT MODULE POSITION RECORD: 1 CONT. ENCLSR. VR REMOTE ALARM 5 SPARE 2 ADDITIVE TURBINE 6 SPARE 3 SPARE 7 SPARE 4 SPARE 8 SPARE GROUND 0 0 VEEDER-ROOT NOTE: CONTRACTOR TO DOWNLOAD AND PRINT EXISTING ALARM HISTORY & SENSOR SETUP PRIOR TO STARTING ANY WORK ON THE EXISTING VEEDER-ROOT PANEL. PLACE PRINTOUT INTO EXISTING "DESIGNATED OPERATOR" BINDER IN THE CONTROLLER ENCLOSURE. (\ Existing Veeder Root Console Module Configuration NOT TO SCALE: \TR I\ S I CAS Y-SAFF AR I- A GOU\D 0 0 8 MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 4 8 I MODULE TYPE: NOT USED POSITION RECORD: 1 5 2 6 3 7 4 8 6 MODULE TYPE: PLLD INTERFACE MODULE POSITION RECORD: TURBINE PLLD 1 REG. UNLEADED #1 5 SPARE 2 REG. UNLEADED #2-,_6 SPARE 3 PREM. UNLEADED #1 NEW 4 SPARE 5 MODULE TYPE: NOT USED POSITION RECORD: 1 56 2 3 7 4 8 �i MODULE TYPE: INTERSTITIAL SENSOR INTERFACE POSITION RECORD: ADDITIVE TANK SENSORS 1 DISPENSER 15/16 5 DISPENSER 19/20 2 ADDITIVE ANNULAR 6 SPARE 3 ADDITIVE TURBINE SUMP 7 S P 4 DISPENSER 17/18 i g SPARE 3 MODULE TYPE: INTERSTITIAL SENSOR INTERFACE POSITION RECORD: TURBINE/DISPENSER SENSORS 1 PREM. UNL TURB 5 DISPENSER 7/8 2 DISPENSER 1 /2 6 DISPENSER 9/10 3 DISPENSER 3/4 7 DISPENSER 11/12 4 DISPENSER 5/6 8 DISPENSER 13/14 2 MODULE TYPE: INTERSTITIAL SENSOR INTERFACE POSITION RECORD: TURBINE/FILL/ANNULAR SENSORS 1 REG. UNL A ANNULAR 5 REG. UNL B FILL 2 REG. UNL A FILL 6 REG. UNL B TURB 3 REG. UNL A TURB 7 PREM. UNL ANNULAR 4 REG. UNL B ANNULAR 8 PREM. UNL FILL 1 MODULE TYPE: PROBE INTERFACE MODULE POSITION RECORD: TANK LEVEL GAUGES 1 REG. UNLEADED A 5 SPARE 2 REG. UNLEADED B 6 SPARE 3 PREM. UNLEADED 7 SPARE 4 ADDITIVE 8 SPARE GROUND 0 0 Module Configuration NEW 0 0 m 0 y Q 0 0 0 0 z W Z 0_ I— U W z Z 0 0 0) 0 Q Q 0 Z Q 0 0 cc W 0 W r cc 0 0 J U LL w z J 0 0 0 O U r r r GILBARCO D-BOX #1 (DATA)O TYPICAL 1-8 DISPENSER SIDE TYPICAL 9-16 DISP #9 9A 9B I I I I DISPENSER SIDE I I I I TO EXISTING POWER PANEL (DISPENSER #1) GILBARCO D-BOX #2 (CRIND) 0 TYPICAL 1-8 CRIND #1 1A 1B I I 1 CRIND SIDE I 1 TYPICAL 9-16 CRIND #9 9A 9B I I I I CRIND SIDE I I I I I I 1 I I I I I O I L. L 11VI' JiVIL I L L MINIMUM #12 AWG o z DISPENSER #1 1 2 3 4 PUMPS DATA 0- 0- CARD ® - READER 9 #14 TWISTED PAIR PER MANUFACTURER'S SPECIFICATIONS TO SITE CONTROLLER DATA 1-4 (Output) 010 010 0 20 7A 5B 41 /B DATA 5-8 (Output) O O10 O10 O10 0 0* 78 QA 68 7A 7B 8A 88 00 ptional Expansion to Other Board 1A 1E1 21 TB it 78 4A 48 Q 910 010 010 I I DATA 1-4 (Input) 1 I I J 5A 6A 68 76 78 61 M O ,3)10 010 O10 0 DATA 5-8 (Input) ENLARGED VIEW (DATA) I I I 1 I I I I- L EXISTING ) POWER INTEGRITY SURGE PROTECTOR AND DATA DISCONNECT UNIT (DISPENSERS #1-8) O O 1 1 <- I I I I I I I II I #14 TWISTED PAIR PER MANUFACTURER'S SPECIFICATIONS TO SITE CONTROLLER Crind 1-4 (Output) Grind 5-8 (Output) a aIo oIo 010 1A 18 21 28 SA 58 6A 48 o1A 18 21 ffi 5A 36146 B 40 48 Q10 O10 O10 0 — 1 I Crind 1-4 (Input) I I I I I J I J TYPICAL GASOLINE DISPENSER FIELD WI 00100100100 5A 58 8068 31 78 84 88 co co 1_ Optional Expansion from Other Board 51 58 6A 88 7A 78 dA 88 O 010 010 O10 O Crind 5-8 (Input) ENLARGED VIEW (GRIND) B 0 1- SING TO EACH MODULE 0 r r r I I I 1 1 1 1 I I I I I 1 I I I I I I I I I I I I I I I I I I MINIMUM #12 AWG 6600666e DISPENSER 120V HOT o 1 2 3 4 a I' PUMPS N N 0 J 0 DISPENSER #9 0 DATA S- G- CARD - READER - TO EXISTING POWER PANEL (DISPENSER #9) 0 7 _ I I I I I I I I I I I I I I I I I I I I I I I I I I IL L - #14 TWISTED PAIR PER I I MANUFACTURER'S SPECIFICATIONS I I I I TO SITE CONTROLLER DATA 9-12 (Output) DATA 13-16 (Output) O b10 010 010 O 81 98 10A 10B 11A 118 12A 12B 1- 0 010 010 010 0 13A 156 16A 146 151 158 16A 168 QIl 1. 000 Optional Expansion to Other Board 9A 98 Otb115810 1U O11810 17A O120 4 Q10 1 1 DATA 9-12 (Input) I I ENLARGED VIEW (DATA) -J 12815B 144 148 16A 15B 164 168 O 010 O10 010 O DATA 13-16 (Input) B Dispenser Data Positive Shutdown Wiring Diagram E-4 NOT TO SCALE: co F- N m 67 NEW POWER INTEGRITY SURGE PROTECTOR AND DATA DISCONNECT UNIT (DISPENSERS #9 -16) KEY NOTES: 0 0 0 0 0 0 1 #14 TWISTED PAIR PER MANUFACTURER'S SPECIFICATIONS TO SITE CONTROLLER Crind 9-12 (Input) POWER INTEGRITY SUPPLIED TRANSFORMER. DEDICATED RECEPTACLE CONTROLLED BY THE EXISTING ESO SWITCH SYSTEM. REFER TO WIRING DIAGRAM, DETAIL-D ON SHEET E-2. EXISTING GROUNDING LUG CONNECTION POINT. POWER INTEGRITY DISPENSER DATA DISCONNECTING BOX MUST BE GROUNDED IN ORDER TO PROVIDE THE PROPER PROTECTION. REFER TO THE MANUFACTURES RECOMMENDATIONS. PROVIDE #12, GREEN INSULATED GROUND WIRE. EXISTING CONDUIT AND CABLING TO REMAIN. REMOVE EXISTING CONDUITS AND WIRES BETWEEN THE EXISTING DISTRIBUTION BOX AND DISPENSER CONTROLLER. PROVIDE NEW 3/4" CONDUIT WITH #14 TWISTED PAIR (PER MANUFACTURES RECOMMENDATION) FROM THE EXISTING DISTRIBUTION BOX AND DISPENSER CONTROLLER TO DATA DISCONNECT BOX. POWER INTEGRITY DISPENSER DATA DISCONNECT BOX. RE -WIRE EXISTING DATA AND CRIND AS SHOWN. Crind 13-16 (Output) 0 010 010 010 0 1SA 15B 16A 148 1S1 168 161 168 Optional Expansion from Other Board 'Jr) J 1 13A 16B 11A 11B 0 1S1 158 1a 168 O O10 1O10 O O Crind 13-16 (Input) — ENLARGED VIEW (CRIND) m INSTRUCTIONS: NOTE: WHEN TEMPERATURE IS BELOW 50°F (10°C), KEEP RESIN IN A WARM PLACE PRIOR TO MIXING (e.g., IN AN INSIDE POCKET NEXT TO BODY). 1. REMOVE GUARD BAG, USING CAUTION NOT TO DAMAGE INNER BAG. 2. GRIP BOTH EDGES OF BAG AT THE CENTER BARRIER, WHILE YOU FLEX AND WRINKLE THE BAG ACROSS THE BARRIER, THIS WILL WEAKEN THE BARRIER. 3. SQUEEZE THE CLEAR SIDE OF THE RESIN, FORCING THE RESIN THROUGH THE CENTER BARRIER. 4. MIX THOROUGHLY TO A UNIFORM COLOR BY SQUEEZING CONTENTS BACK AND FORTH 25-30 TIMES. 5. SQUEEZE RESIN TO ONE END OF BAG, AND CUT—OFF OTHER END. 6. SLOWLY INSERT CONNECTION INTO SEALING PACK UNTIL IT FITS SNUGLY AGAINST THE OPPOSITE END. 7. TWIST OPEN END OF BAG AND USE TIE WRAP TO CLOSE IT OFF, OR WRAP OPEN END OF BAG WITH VINYL ELECTRICAL TAPE AND POSITION THE TAPED END UP UNTIL THE RESIN JELLS. OUTER BAG TO CONSOLE TO SENSOR/PROBE ZIP TIE CABLE JACKET TO BE SEALED INSIDE THE RESIN WIRE NUTS RESIN BAG REVIEWED FOR PLIANCE WITH FPA 70 o NEC • FEB 19 2014 Cfty of BUILDING DIVISION Cc� Veeder Root Splicing Detail E—� NOT TO SCALE: RECEIVED CITY OF TUKWILA FEB 18 Z014 PERMIT CENTER W iN J Q > 0 CA 00 W cc Cn 0 LI =W� 0Ja U0)0 co O) 0 2 MASTER RELEASE a) 0 U (n 0 r-. 0 N 00 z 8 < Z Designed OV/RGF LL 0 0 0 0 (n M 0 C 0) 0 18215 72ND AVENUE SOUTH N N � N O N o I N N w x N CO CO z_ z z 0 Qz C9 z_ w w w (n w 0 w (n J z w z 0 tz z w 0^ (n Job Number 0 oo 00 O 0 0 11 0 N 0 0 (n Date/Time:2/3/2014 9:12 AM File:P:\07000s\7880\mechanical\tanks\2013 Expansion\7880 E-4.dwg