Loading...
HomeMy WebLinkAboutPermit M14-0033 - LIFESTYLE LANDSCAPING - ROOFTOP HEAT PUMP REPLACEMENTUFESTYLE LANDSCAPING 11234 TUKWILA INTERNATIONAL BLVD M14-0033 City of Tukwila Department of Community Development O 6300 Southcenter Boulevard, Suite #100 �`n 2 Tukwila, Washington 98188 190E Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: Project Name: MECHANICAL PERMIT 0923049411 Permit Number: M14-0033 11234 TUKWILA INTERNATIONAL BLVD 1 LIFESTYLE LANDSCAPING Issue Date: 2/20/2014 Permit Expires On: 8/19/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: RAMSDEN KENTA PO BOX 1766 , EDMONDS, WA, 98020 JOFFRE SECHIER 3202 C ST NE , AUBURN, WA, 98002 COMFORT MECHANICAL INC 6617 S 193 PL, #P-105 , KENT, WA, 98032 COMFOM1015LA Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2014 DESCRIPTION OF WORK: REPLACE 1 2.5 TON ROOFTOP HEAT PUMP WITH LIKE UNIT. Valuation of Work: $6,000.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $272.02 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: eac C C _' 144 r C-/) Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. ifii)l «-0o33 Date Application Accepted: Date Application Expires: Oq 07/ y (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION I u (r King Co Assessor's Tax No.: O _I L „ ot4 - Z '! I Site Address: 11 2. 3 l lh43rr14 T; oha l 6LVD Suite Number: Tenant Name: L I -FLS4-y fe L it As ' p; j PROPERTY OWNER Name: ? 4iiiS en Address: rl Z3 if _Ln fernC1Ironail $I V61 City: T `t` kw r 1 `Li State: {, J A.Zip: if eg S CONTACT PERSON — person receiving all project communication Name: JofFrg 5 e (A T e.r Address: Q 2 C s 1 A'V► �' City: 4�rt.,� �rState: WA. Zip: •18 002. Phone: q, Ls- _i f( _d2yOFax: .3- Email: j o-f f•Fre G co rhfor 1 1'he c/ . co I Floor: New Tenant: ❑ Yes E..No MECHANICAL CONTRACTOR INFORMATION Company Name: i L0kurfor`, �- ACc4ein<<al Address: 32.02 o2 C. L A j E G4, City: /► r r n State:rW A ZiP:tfgOo2 Phone: 4 e 'r 2J I " tte: 2s3.. 736. 651i Contr Reg Noo.:L 0/id Ch �/{roIF,, Date: y�/ 111 ` Tukwila Business License No.: OKi3 3 6 s Valuation of project (contractor's bid price): $ 6/ D OQ Describe the scope of work in detail: iRePlaC,6 t Ton Roo-f--/9e heat p Use: Residential: New Commercial: New • Fuel Type: Electric Gas Replacement Replacement Other: -A L;I�e cAni II: \Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit ( <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: Print Name: ¢R AUTHORIZED AGENT: -&tii-tte Se: c..t.rtt Mailing Address: 32.Z C." Si AI Date: Day TelephoneF2' (- 9 4c Au akaki V/4 60Z City State Zip H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS I ACCOUNT PermitTRAK QUANTITY PAID $272.02 M14-0033 Address: 11234 TUKWILA INTERNATIONAL BLVD 1 Apn: 0923049411 $272.02 MECHANICAL $261.56 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $176.75 PLAN CHECK FEE R000.322.102.00.00 $52.31 TECHNOLOGY FEE $10.46 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R984 R000.322.900.04.00 $10.46 $272.02 Date Paid: Wednesday, January 29, 2014 Paid By: COMFORT MECHANICAL Pay Method: CREDIT CARD 319262 Printed: Wednesday, January 29, 2014 11:26 AM 1 of 1 INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: Address: Date.Called: Special Instructions: Date Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: REINSPECTION FEE next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2.5T PHP-Horiz Project: Lifestyle Landscapes Prepared By: 01/22/2014 10:52AM FILE COPY Permit No. 2.5T PHP-Horiz Tag Cover Sheet Unit Report Certified Drawing Performance Report REVIEWED FOR CODE COMPLIANCE APPROVED FEB 13 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 2 9 2014 PERMIT CENTER Packaged Rooftop Builder 1.39e loll tool 4.01. 001 Unit Report For 2.5T PHP-Horiz Project: Lifestyle Landscapes Prepared By: 01/22/2014 10:52AM Unit Parameters Unit Model. 50EZ-A30---3 Unit Size. 30 (2.5 Tons) Volts -Phase -Hertz. 208-1-60 Heating Type. Heat Pump Duct Cfg Horizontal Supply / Horizontal Return Warranty Information 1 year warranty on parts 5 year warranty on compressor Dimensions (ft. in.) & Weight (Ib.) """` Unit Length. 4' 0.1875" Unit Width. 2' 8.625" Unit Height. 3' 5.9375" Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Total Operating Weight -340 Ib tc�No Ads, (S li 40-C No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50EZ-A30---3 Rooftop Unit 1 Base Unit Accessories CPHEATER070A00 5.4/7.2 kW, 208/230-1-60 volt, Electric Heater 1 CPECOMZR010A00 Horizontal Economizer 1 CPRLYKIT001A00 Economizer relay kit for heat pumps 1 Packaged Rooftop Builder 1.39e Page 2 of 6 Certified Drawing for 2.5T PHP-Horiz Project: Lifestyle Landscapes Prepared By: 01/22/2014 10:52AM E URN 3-15/16 1252.41 SUPPLY 15-15/16 1/04.8. OUTDOOR COIL 3" 981 7 / 155 3-5/8 192.11 `PAIN OUT_:7--1 T5(13.31N 'T. x L56122 ,I' F LEFT SIDE VIEW 12-13 'E 1325.4: 02TI0NAL OPTIONAL RETURN A:R j j\\; SUPPLY AIR OPENENG INDOOR COIL TOP VIEW -ELECTR:CAL ACCESS PANEL COH'RESSOR'- PANE- /16 '1224 0. -6_/WER P/Ail FRONT VIEW UNITED AT. NCA 43:e T/CH`0-OGEES uu:431. NI CARRIER 14221 TNf DJCINEN7 :.F -AF PI 'Y J CARR:IF 3 'Ti tN IS 1F(IV:F F: JREV T-F.IF•F [ES LSD r.9S TNli CJY 0A'S 31, .NOT71 RE CCONSENI. OP LSD •:1tJ_ CA [JTIOFA I:JV'i ARI'iFY CONi[tll. EL-CTRICAL 1:14EACTER:S-ICS 1A1T WT. /N1T HEIGHT :N/MN ^.EATER OF GPAV:T/ IN/YM 53E2-4,24---3C 208/233-1-69 406.4 5DEZ-535---13/510 208/230--. 200/233-3-60 332 150.7 42-1/8 1373 '9-3/4 531.7 "4-3/4 314.' 16 406.4 1.0E3-436---13/0)0 208,230-1. 236/230-3-60 336 ,152.3 42-1/8 107D "9-3/4 SO1.1 14-3/4 374.' 16 406.4 55E2-05---6C 463-3-60 350 '158.6 42-1/8 1670 '9.3/4, 501.7 14-3/4 314.' 16 406.4 50E2-124---30 1208/230,64. 0.29.0 51.2:23.2 76.7 34.81127.9 58 1 50E0-A39---13/510 1208/230165.5139.2 53.2124.1 79.7 36.2,132.9 60.3 56E2-A36---13/5'3 1208/230167.2 130. 5 53.-124.4 83.5 36.61134.3 61.0 50E2-A36---60 , 460 167.2:30.5 53.1124.4 89.6 49.7:139.3 63.2 NOTE: ALL TABLE DATA RELEVANT FOR AL' FACTORY INSTALLED OPTIONS EXCEPT ECONOMIZER yl 1.3/4 '44.51 :IA. K.C. POWER. CATTY 12 • 3/1- 1325.41 7-'/4 [184.21 i/16 :4.81 T-7/16 197•3' w -4-13/16 C01T7:1 E2f-R ['22 21 RIGHT SIDE VIEW REQUIRED CLEARANCES TO CONSUST®L.E WAIL INCHES [NMI TOP OF UNIT 14 1355.61 DUCT SIDE OF UNIT 2 [SD.B] SIDE OPPOSITE DUCTS 14 [355.61 BOTTOM OF UNIT 0 [O.L1 ELECTRICAL PANEL 36 [914.41 AEC. REMISED CLEARANCES BETWEEN UNITS. POWER ENTRY SIDE UNIT AND UNGROUNDED SURFACES. POWER ENTRY SIDE UNIT AND BLOCK OR CONCRETE WALLS AND OTHER GROUNDED SJ4'ACES. POWER ENTRY SIDE ITC -ES -1411 42 1066.81 36 314.01 42 11066.81 REWIRED CLEARANCE FOR OPERATION AND SERVCNO INCHES NMI EVAP. COIL ACCESS SIDE 36 [914.31 ' POWER ENTRY SIDE 42 11066.81 'EXCEPT FOR NEC REDU':REMENTS/ JNIT TOP ' 48 11219.21 '. SIDE OPPOSITE DUCTS 36 (914.01 DUCT PANEL 12 (304.81A • 4MINIYUM DESTA.9CES:12 UNIT IS PLACED LESS THAN 12 1304.81 FROM WALL • SYSTEM.THEN SISTER PERFORMANCE MAYBE COMPROMISED. DIMENSIONS III f'. ARE IN MM RIPPLY CE/I CPE IIING REAR VIEW RE CCCT CPC NING SIEEFLE4E3 5IV'3LF ZONE EL-i'iFl: ;,'ol_tdG A FEAT .S1.i] 3.0 Packaged Rooftop Builder 1.39e Page 3 of 6 1 FORM NO. 8586-1P SUBMITTED TO. COMPANY - DRAWN BY- T. HUBBARD JOB NAME: EQUIPMENT: NOTES: Econo. Part No. ECH-SDSML-ADB-CD ECH-SDSML-ENT-CD ECH-SDSML-NC-CD Controls Dry Bulb Enthalpy No Controls Horizontal Discharge Economizer with Filter Rack for Carrier 48/50ES,EZ,VL 024-036,A24-A36; 48/50VT 024-030,A24-A30; 50GL,JZ 024-036,A24-A36 Units Part Number: ECH-SDSML ** Features: • Economizer for horizontal application only. • Fully assembled, easy to install. • 2" Filter rack and 1" TAW filters provided. • Rainhood ships assembled, includes a water entrainment filter and is constructed of prepaint steel. • Low leak outside air damper. Economizer Optional 0876-0300 Relief Damper Filter Access Door Coil Replacement panel shipped with economizer (some newer units will include this panel) Rainhood with water entrainment filter Carrier Equivalent: CPECOMZR010A00 FILTER RACK SIZE 1" Filters (2) 12" x 20" x 1" 2" Filters (1) (1) 10"x20"x2" 12"x 20" x 2" NOTES: 1. Relays required for heat pump units can be field supplied or order Carrier Kit CPRLYKIT001A00. 2. Economizer should not be used on XL,XT INFINITY units. 3. The "NC" economizer models do not include actuator, controller, sensors, or wiring harness. 00 00 00 00 00 00 00 00 00 00 00 00 00 00 Filters provided SIDE VIEW Aluminum water entrainment filter Horizontal Duct Opning THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED VMTHOUT MICROMETL'S WRITTEN CONSENT MICROMETL CORP. - 3035 NORTH SHADELAND AVENUE. SUITE 300 - INDIANAPOLIS, IN 46225 - 1-800-652-4822 - MICROMETL SPARKS - 905 SOUTHERN WAY - SPARKS. NV 89431 - 1-800-884-4662 Performance Summary For 2.5T PHP-Horiz Project: Lifestyle Landscapes Prepared By: 01/22/2014 10:52AM Part Number:50EZ-A30---3 ARI SEER 13.50 Base Unit Dimensions Unit Length. 48.2 in Unit Width:. 32.6 in Unit Height 41.9 in Total Operating Weight 340 lb Unit Unit Voltage -Phase -Hertz. 208-1-60 Air Discharge- Horizontal Fan Drive Type. Direct Actual Airflow. 954 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB' 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy. 31.44 BTU/lb Evaporator Leaving Air DB. 59.2 F Evaporator Leaving Air WB• 57.5 F Evaporator Leaving Air Enthalpy' 24.74 BTU/lb Net Cooling Capacity. 28.75 MBH Net Sensible Capacity. 21.41 MBH Total Unit Power Input 2.51 kW Coil Bypass Factor 0.155 Heating Performance Outdoor Ambient Temperature. 47.0 F Entering Air Indoor Coil DB. 70.0 F Leaving Air Indoor Coil DB 98.3 F Total Heating Capacity. 29.10 MBH Integrated Heating Capacity. 29.10 MBH Heating Power Input 2.42 kW High Temperature COP. 3.5 Low Temperature COP. 2.2 HSPF. . 7.7 Electric Heating Capacity. 5.40 kW Unit Leaving Air Temp- 116.1 F Supply Fan External Static Pressure. 0.30 in wg Options / Accessories Static Pressure Economiser 0.15 in wg Wet Coil* 0.06 in wg Total External Static. 0.51 in wg Fan RPM. 0 Fan Motor Size, hp. 1/2 NOTE. High Motor Speed, Horz Electrical Data Minimum Voltage. 197 Maximum Voltage. 253 Compressor RLA. 16 Compressor LRA. 73 Actual Electric Heater kW 5.4 Electric Heater FLA. 25.9 Packaged Rooftop Builder 1.39e Page 4 of 6 Performance Summary For 2.5T PHP-Horiz Project: Lifestyle Landscapes Prepared By: 01/22/2014 10:52AM Outdoor Fan FLA (ea). 1.2 Indoor Fan Motor FLA. 4.1 Power Supply MCA- 57.7 Power Supply MOCP (Fuse or HACR). 60 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating. 76.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 60.5 250 Hz NA NA 67.5 500 Hz NA NA 72.0 1000 Hz NA NA 70.0 2000 Hz NA NA 67.0 4000 Hz NA NA 61.0 8000 Hz NA NA 51.5 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground- 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1 k 2k 4k 8k Overall A 0.0 60.5 67.5 72.0 70.0 67.0 61.0 51.5 75.9 Lw B - 26.2 44.4 58.9 68.8 70.0 68.2 62.0 50.4 74.3 LwA C 0.0 28.1 35.1 39.6 37.6 34.6 28.6 19.1 43.5 Lp D - 26.2 12.0 26.5 36.4 37.6 35.8 29.6 18.0 41.9 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA Packaged Rooftop Builder 1.39e Page 5 of 6 Performance Summary For 2.5T PHP-Horiz Project: Lifestyle Landscapes Prepared By: 01/22/2014 10:52AM C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.39e Page 6 of 6 FILE COPY REVIEWED FOR CODE COMPLIANCE APPROVED FEB132014 City of Tukwila BUILDING DIVISION Q* w- 61,„ z'#i 8959 V OVAL EXPIRES STRUCTURAL CALCULATIONS t114( Life Style Landscape RTU 11234 International Boulevard Tukwila, Washington JANUARY 23, 2014 PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington Moore Engineering Group RECEIVED CITY OF TUKWILA JAN 2 9 2014 PERMIT CENTER lei- 00;3 GENERAL STRUCTURAL NOTES: I . ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2012 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT 405 POUNDS EARTHQUAKE Sps = 0.962 SI ib CLASS D to E WIND 85 MPH, EXPOSURE B 3. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 4. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND • STRUCTURAL COMPONENTS UNI1L ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METIIODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 6. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL 1NSTITU FE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 7. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B18.6.1. 8. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 9. CONNECT THE UNIT TO THE EXISTING PRESSURE TREATED WOOD SLEEPERS WITH ONE 1-1/2" WIDE GALVANIZED, BENT SHEET METAL STRAP IN EACH CORNER. CONNECT THE STRAP TO THE UNIT WITH ONE #10 GALVANIZED SHEET METAL SCREW AND TO THE WOOD SLEEPER WITH ONE #10 x 2" LONG GALVANIZED WOOD SCREW. PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop mechanical unit with a new unit. LOADS: LIVE 25 PSF DEAD Roofing and re -roof 4.0 Plywood sheathing 1.5 2.x10 @ 24" o.c. 1.9 4x14 @ 13' o.c. 1.0 Insulation 1.0 MEP 2.0 Ceiling & Lights 2.0 Total Dead 13.4 DEAD + LIVE WIND 85 mph, Exposure B SEISMIC 38.4 PSF Latitude 47.502 Longitude -122.293 Site Class D to E WA DNR SOS (D) = 1.013 SDs. (E) = 0.911 SDS 0.962 EQUIPMENT Existmg New Unit 306 340 Economizer 65 Total 306 405 Dimensions 48"x33"x42" high oore Engineering Group PROJECT: LIFE STYLE LANDSCAPE RTU ENGR: KWM DATE: 1/2311 4 SCALE: SHEET Design Maps Summary Report Page 1 of 2 Design Maps Summary Report User -Specified Input Report Title Life Style Landscape Fri January 24, 2014 00:14:49 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.502°N, 122.293°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III 15009m QG81ewood Go*ley 0 oVashon mapquest USGS-Provided Output Ss = 1.519 g Sl = 0.571 g S„s = 1.519 g SMl = 0.857 g oNewcast.le Curl:J• ,•;.ti FLrt Xir ti N0Rfi-i� S06 = 1.013 g S°1 = 0.571 g AMERICA East MapQutst For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.76 1.60 1.44 1.29 1.12 CT 0.96 0.30 0.64 0.48 0.32 0.16 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.80 1.09 1.20 1.40 1.60 Period, T (sec) 1.90 2.00 1.10 0.99 0.99 0.77 1 0.66 H OM 0.44 0.23 0.22 0.11 0.00 0.00 Design Response Spectrum 0.20 0.40 0.60 0.90 1.00 1.20 1.40 1.60 1.80 Period, T (sec) 2.00 http://geohazards.usgs.gov/designmaps/us/summary php?template--minimal&latitude=47.5... 1/23/2014 Design Maps Summary Report Page 1 of 2 usGs Design Maps Summary Report User -Specified Input Report Title Life Style Landscape Fri January 24, 2014 00:15:10 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.502°N, 122.293°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/II/III 1 500000ns BGaleweod a C°wlny oVashon • mapquest USGS-Provided Output Ss = 1.519 g Si = 0.571 g 0rgel0Mjl S„s = 1.367 g S„1 = 1.371 g QNewcastle East AM ERICA ®20 m MapQuest Sos = 0.911 g Sol = 0.914 g For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. a R N 1.40 1.26 1.12 0.99 0.24 0.70 0.56 0.42 0.29 0.14 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.20 Period T (sec) 2.00 Design Response Spectrum 1.10 - 1.00 0.90 - 0.20 - 0.70 - a 0.60 w a 0.50 0.40 0.20 - 0.20 - 0.10 - 0.00 i ! ► ! i 1 1 I 1 1 0.00 0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.90 2.00 Period, T (sec) http://geoha7ards.usgs.gov/designmaps/us/summary.php?template-minimal&latitude=47.5... 1/23/2014 drawing frame wall bearing General Information This manual covers the installation. operation and maintenance of Model BWCO24C. 030C & 036C single package heat pumps. Unit Inspection Check the unit carefully for any shipping damage. Report any damage immediately to and Se aclaim with the delivering carrier: Replace damaged parts with authorized parts an Power Supply The power supply must be adequate for the unit and any supple- mentary electric heaters, if added. Make certain that the power supply to the unit agrees with the pow requirements specxfled on the unit nameplate. Separate branch circuits are required for supplementary electric heaters. Filters These units require filters with adequate fitter area provided in the return air duct. Table 1 lists filter data. The specific location of the filters depends on the type of installation and the layout of the duct system. Be sure the owner is aware of the location of the ftlter and the need to change them as required. If face velocity exceeds 300 fpm, hi -velocity filters ate required. Table 1 - Filter Data Installation Location and Recommendations For proper installation, the following recommendations must be considered: 1. There must be sufficient clearance around the unit to provide easy and unrestricted access to service punnets. Figure 1 pro- vides unit dimensions and recommended clearances. 2. The unit should not be subjected to direct roof water runoff. 3. Elevation minimums must be maintained for drain line traps and ventilation of the base pan. 4. Flame proof flexible duct connectors should be used on supply and return ducts mating to the unit. 0 Atnerca., SlaMar0. Tc (485 2 5. Ductwork inside the building should be adequately insulated. Ductwork outside the building must be insulated and weather- proofed in accordance with local codes. 6. Field supplied mounting pads should be used beneath the unit to prevent the transmission of vibration to the building. T. to areas where heavy snowfall is common. raise the unnit a nwtimum of twelve inches off the roof or slab to reduce the chance of the cal being blocked with snow. Also, the water from the defrost cycle will flow away from the unit better Avoid locating the unit where snow tends to drift Snow ac- cumulation ulation should be removed from the sides of the unit for best of lcienc1k B. Locate the unit so that eater vapor discharging upward during the defrost cycle does not condense on windows or cause icicles to form on overhangs. Rigging Before preparing the unit for lifting, estimate the approximate center of gravity for lifting safety. Because of placement of internal components, the unit weight may be unevenly distributed. Ap- proximate unit weights are given in Table 2. Table 2 - Unit Weights BWC-024C BwC-030C BWC-036C 321 337 371 :r 290 306 340 %1r`}C"t3L), Before hoisting the unit, be sure that the proper method of rigging is used. with straps or slings and spreader bars for protection during lifting. Always test -lift the unit to determine exact unit balance and stability before hoisting it to the installation location. WARPING: DO NOT UFT THE UNIT WITHOUT TEST-UFTING FOR BALANCE AND RIGGING.. DO NOT UFT THE UNiT IN WINDY COMMONS OR ABOVE PERSONNEL. DO NOT UFT THE UNIT BY ATTACHING A CLEVIS, HOOKS, PINS OR BOLTS TO THE UNIT CASING, CASING HARDWARE, COR- NER RIGS, ANGLES. TABS OR FLANGES. FAILURE Tb OB- SERVE THESE WARNINGS MAY RESULT IN PERSONAL INJURY OR DEATH OR EQUIPMENT DAMAGE. Unit Report For 2,6T PHP-Horiz Project: Lifestyle Landscapes Prepared By: 01/22/2014 10:52AM Unit Parameters Unit Model: . 50E24430-3 Unit Size:.. 30 (2.5 Tons} Volts -Phase -Hertz .208-1-60 Heating Type: Heat Pump Duct Cfg:_._ __Horizontal Supply i Horizontal Return Warranty Information 1 year warranty on parts 5 year warranty on compressor No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) *** Unit Length: 4' 0.1875" Unit Width' , 8.625" Unit Height.. ,.3' 8.9375" *** Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarfiy for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Total Operating Weight 340 Ib &Ott 400 (17,,S hp) 0•40s, NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description +Quantity 50EZ-A30--3 Rooftop Unit 1 Base Unit Accessories CPHEATER070A00 5.4/7.2 kW, 208/230-1-60 volt, Electric Heater 1 CPCD-OMZR010A00 Hortzontal Economizer 1 CPRLYKIT001A00 Economizer retay kit for heat pumps 1 Packaged Rooftop Builder 1 39e Page 2 of 6 Certified Drawing for 2.5T PHP-Horiz Project: Lifestyle Landscapes Prepared By: 01/22/2014 10:52AM 30 01-.1 .31 00/340R COI/ ••---- 3" /$16 ../2111 SI 4-14411 1-10370 +- .252,41 :341.11 12/2,41 PE70447 1 0/174634 RETURV dIR 083447100, TOP VIEW It 43 „4; at —1 CAS . t ' 1sAtA senas cAtt sr :51“1-,ille'a CStt 3III 1 11WI161. illtzvvgifv. i $.11I^ L /141210110:5'200 • /3 ' te ± A . Sll; _F-1, LS17 SSIGII7 :NM CEST/12 02 (ISAY:7711;SAI 1 I 2 . I 12a 1447rdr-T:16-7-TCY6-":4;:/771•70177:1 71:371:7 7577— -71:6671:: 1/21 -131.1:2; 2064236 265423)-1-44 1 112 150,1 41116 445 56E2-434---211310 260,261'1, 2/01210-3-00 134 .152,4 42-116 . 1010 4-274 .11, 435— 44 , 41.2.-3-65 I 330 116,3/ 42-110 107C '4-113.S31.7 ; COWS fellir AIMS UNITS ;SOAISS1.1- ,. qa --I —30 i264+236l62.0,24.0 5: .2'23.2214.1 14.6022,31525 11 .„....1 5021-1121---II701 1240/23/$50,S,33.2 51.2;24.1119:1 35.21132,4M.) 301:1-136-.;:a4)0 1246/23/42:2:31.6 43,1:1:1474140,6116,11134,3161.0 3/22-1111-••60 ; 433 :8/.2333 43.2i24.039,1144./I134.3013•2 ".,E! hamtp gomv4.04 " ,""" lor,"" ,:won OOZE IIiUIHIIIIIIIIII 11111111111111111 0 0' •-, • ;TM, 70 7-174 '44 51 Ils. f: P70411 2.1.411 "••. •i' I4 315,4)1.;;4 tla4.81 NOM 401'7I IS01- L LEFT SIDE VIEW Packaged Rooftop Budder 1.39e .-NT -4 FRONT VIEW 1L1 \ 1•1fit 1353 f0r11‘.- MIME) 0(EARA11666 TO 00616/162161E 7.4;;Si0)11., 14-014I 114. ' 14-314; 374.7 1 e It It 06 4 OSA 406 4 • ISCReS Mel /OP Of 1111- 14 td36,41 DIV SIDE Of ORM 2 MAI $102 OPPOSITE ROCS Id 435531 OTROS Or VW .,0 NA) itiCialtAl. PAK& IS 4811,41 IAA AD71,19 ADM= LEts 0,40 SEtlf Ett 13 i TS , POPO ESTE' SIRE ... : ....... ,... ,„„,„.42 2346,81 AU IND 111011011600 3124710E3. MIER 21$164 SIDE SS 7044.47 Alf OD 6,0C41 OR C0101121f 114.1.4 ASO OfIRS 4.1011210E0 41 ACES, 83300 08167. 42 •I-0663, maxim amass Mt Mititaii NA moo IIIESED 9014 2241, COM 4CC603 MX 36 2414./1 42 2106e .6I Ilit,l'ig lif,,,,,,,"-Apekls, • 4/12/ TOP 46 1121611 I SIDE 07705203 344'5. 36 4614,41 i 012e 7 1061. IS I334.111. ; •6141444 OISTARCES:If 017 IS Alltil :SSS "VS It 4314,3I /SOS VALI_ 3207214,11111 STS/214 2211201061662 44212 t3440444(3E). •i 1).1iS 110).n [V.1 111 r 1:410SIt151 IS (I An 03 AS; 1111111011111111111 11111111111111NI 2.11/P1/ 9E1/11 r 5168 cAtiiIAS eFtsISI 601061111111011 1- t$18--1 1./43 2i-5.8 ) )81 PS; 8; '51).81 ;81).17 RIGHT SIDE VIEW REAR VIEW (4707 1ION 11 SM) 5,Y:7SC',;357 Page 3 of 6 77 (el ci Moore Engineering Group C De .i3 8 ENGR: DATE: I 7--4 SCALE: SHEET PERMIT COORD curt PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0033 DATE: 01/29/2014 PROJECT NAME: LIFESTYLE LANDSCAPING SITE ADDRESS: 11234 INTERNATIONAL BLVD X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A-s !Mc Building Division Public Works n F°697"1 ire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 01/30/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Corrections Required (corrections entered in Reviews) DUE DATE: 02/27/14 Approved with Conditions Ni Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 COMFORT MECHANICAL INC Page 1 of 2 Washington State Department ©f Labor & industries COMFORT MECHANICAL INC Owner or tradesperson JACKSON, SHIRLEY A Principals JACKSON, SHIRLEY A JACKSON, HERB J Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA98002 425-251-9840 KING County Business type Corporation Governing persons HERBJJACKSON License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective — expiration 06/01/1999 — 04/25/2014 Bond Lexon Ins Co Bond account no. 9815017 Active. Meets current requirements. $6,000.00 Received by L&I Effective date 06/04/2012 06/01/2012 Insurance Federated Mutual Ins Co $1,000,000.00 Policy no. 9849307 Received by L&I Effective date 05/20/2013 06/01/2010 Expiration date 06/01/2014 Savings No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 02/20/2014 REVISIONS P a rce Number, 1092304-9411 !Name ; RAMSDEN KENT A Site `, 11234 TIJKWILA INTERNATIONAL BLVD 9816 Address? Legal POR GL 2-BEG INTSN OF S LN OF N 435 FT OF SD GL WITH ELY LN OF STATE HWY # 1 TH NLY ALG SD HWY230FTTHE:PLWNLNOFGL110FTTHSLY PLWSDHWY230FTTHWTOBEG ASSESSOR DATA r SITE PLAN NAPA Auto Parts • Gerniine Parts Comply .l¢I fuel Espressn 11234 Tukwila International alvd VICINITY MAP AREA OF WORK PROJECT DESCRIPTION: 1. REPLACE (1) 2.5-TON ROOFTOP PACKAGED HEAT PUMP UNIT WITH NEW 2.5-TON ROOFTOP PACKAGED HEAT PUMP UNIT WITH ECONOMIZER. GENERAL NOTES: 1. ECONOMIZER TO PROVIDE 100% OUTSIDE AIR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. 2. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 3. 7-DAY PROGRAMMABLE THERMOSTAT WITH LOCKOUT. 4. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 5. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF. 6. PROVIDE AIR BALANCE AND COMMISIONING REPORT. 7. PROVIDE O&M MANUALS WITH STAFF TRAINING. 8. INSULATE ALL DUCT PER WSEC. 9. SEAL ALL DUCT PER WSEC. SCOPE OF WORK HP-1 ROOF PLAN - NO SCALE 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary` MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidsntial and Multifamily Residential Project Info Project Address LIFESTYLE LANDSCAPE Date 1/24/2014 11234 International Blvd For Building Dept. Use Tukwila, WA 98168 Applicant Name: JOFFRE SECHIER Applicant Address: 3202 C ST NE, AUBURN, WA 98002 Applicant Phone: 425-251-9840 Project Description Briefly describe mechanical system type and features. n Includes Plans REPLACE (1) EXISTING 2.5-TON ROOFTOP HEAT PUMP WITH NEW 2.5- TON ROOFTOP HEAT PUMP WITH ECONOMIZER. Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option 0 Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTU-1 HP CARRIER 50EZ-A30---3 28750 ECONO 13 ECONO N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N RTU-1 HP Carrier 50EZ-A30---3 29100 ECONO 7.7HSPF N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP/BHP Flow Controls Location of Service 'If available. 2 As tested according to Table 14-1A through I4-1G. 3 If required. 4 COP HSPF, Combustion Efficiency, or AFUE, as applicable. ' Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical eilectrical IfPlumbing [etas Piping C y of Tukwila Bt. i r'' NG DIVISION HVAC Equipment Schedule FILE C PY Permit No. t1i 11~ 003 Plan review approval is subject to errors and omissions. of construction documents does not authorize :.:, lion of any adopted code or ordinance. Receipt 1; approved Field Copy and ors is acknowledged: By Date: ZlZ City Of lbiia BUILDING DIVISION Unit # Brand Model Ton CFM OSA Econo. SF. Cap. Cool SEER Cap. Heat Strip Heat Weight Location HP-1 Carrier 50EZ-A30 2.5 1000 50 0-100 0.5 28,750 13 29,100 5kw 405 Roof /r. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. • NOTE: Revisions will require a new plan submittal and may incude additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 1 3 2014 /FY 04 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 2 9 2014 PERMIT CENTER me®.• 0 ■ F. 253.736.6598 0 00 :o In N to d- DATE : SCALE: DRAWN, 4 CHECKED: 1 00-000