HomeMy WebLinkAboutPermit M14-0049 - EDGE CONNEX - HVAC UNITSEDGE CONNEX 3425 S 116 ST STE133 M14-0049 Citv of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 1023049043 Permit Number: M14-0049 Address: 3425 S 116 ST 133 Issue Date: 4/7/2014 Permit Expires On: 10/4/2014 Project Name: EDGE CONNEX Owner: Name: EPROPERTY TAX INC DEPT 207 Address: PO BOX 4900 , SCOTTSDALE, WA, 85261 Contact Person: Name: KIER VONDRUSKA Phone: (206) 654-2137 Address: 1200 SIXTH AVE #500 , SEATTLE, WA, 98101 Contractor: Name: BURR COMPUTER ENVIRONMENTS Phone: (281) 374-8644 INC Address: 10400 RODGERS ROAD , HOUSTON, TX, 77070 License No: BURRCEI005PP Expiration Date: 8/18/2015 Lender: Name: Address: 1 1 I DESCRIPTION OF WORK: INSTALLATION OF NEW HVAC UNITS Valuation of Work: $375,000.00 Type of Work: NEW Fuel type: GAS Fees Collected: $4,259.72 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: IA42Q Date: aqlDr)li� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: , n✓ � Print Name: .efeic 9,,J j4, 6c,�:�' Date: //-7 _/— This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. 18: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 15: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 21: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 14: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 12: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKW_ Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 littp://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) 0 -00 VI MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: King Co Assessor's Tax No.: / 02- — Suite Number: PROPERTY OWNER Name: Fp (lbr Ty i y I,JVL Doorzo Address: 341/5" i I (o h-t f City: U4-tL.' State: wA Zip: 1,94 CONTACT PERSON — person receiving all project communication Name: ke' fa Vc1 clLusk,4 Address: 1.� l � A. sD O City: 5 4 i State: kiin Zip: Tel©y Phone: Fax: ZOCO (p S9% Z )3') .- _ Email: kE i Iz ----. vat) lJ 0 0. ko /a a'5 4 7 New Tenant: Floor: Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company Name: -� .g ,c> Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 5-O Describe the scope of work in detail: N e +E (JAL JyJ Use: Fuel Type: Residential: Commercial: New ❑ New Electric ❑ Gas Replacement Replacement Other: H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Z. Diffuser 2 7 I Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: -K. , 1/ Print Name: 0 1/a4 .4.1 Mailing Address: 1:7-0C) ix-rw° ,1-ti . 5-� Date: Z IV Day Telephone: (e 1i S V Z/ 3 7 1 City State 9oi Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $21,017.24 D14-0059 Address: 3425 S 116 ST 133 Apn: 1023049043 $3,296.72 DEVELOPMENT $3,199.89 PERMIT FEE R000.322.100.00.00 $1,936.60 PLAN CHECK FEE R000.345.830.00.00 $1,258.79 WASHINGTON STATE SURCHARGE B640.237.114 $4.50 TECHNOLOGY FEE $96.83 TECHNOLOGY FEE R000.322.900.04.00 $96.83 EL14-0145 Address: 3425 S 116 ST 133 Apn: 1023049043 $13,261.24 ELECTRICAL $12,751.19 PLAN CHECK FEE R000.345.832.00.00 $2,550.24 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $10,200.95 TECHNOLOGY FEE $510.05 TECHNOLOGY FEE R000.322.900.04.00 $510.05 M14-0049 Address: 3425 S 116 ST 133 Apn: 1023049043 $4,259.72 MECHANICAL $4,095.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $3,244.20 PLAN CHECK FEE R000.322.102.00.00 $819.18 TECHNOLOGY FEE $163.84 TECHNOLOGY FEE R000.322.900.04.00 $163.84 PG14-0025 Address: 3425 S 116 ST 133 Apn: 1023049043 $199.56 PLUMBING $191.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $121.00 PLAN CHECK FEE R000.322.103.00.00 $38.38 TECHNOLOGY FEE $7.68 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1291 R000.322.900.04.00 $7.68 $21,017.24 Date Paid: Thursday, February 20, 2014 Paid By: BURR COMPUTER ENVIRONMENTS Pay Method: CHECK 9321 Printed: Thursday, February 20, 2014 10:45 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY I PAID $195.00 D14-0059 Address: 3425 S 116 ST 133 Apn: 1023049043 $65.00 DEVELOPMENT $65.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 $65.00 M14-0049 Address: 3425 S 116 ST 133 Apn: 1023049043 $65.00 MECHANICAL $65.00 ADDITIONAL PLAN REVIEW R000.345.830.00.00 $65.00 PG14-0025 Address: 3425 S 116 ST 133 Apn: 1023049043 $65.00 PLUMBING $65.00 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R1941 R000.345.830.00.00 $65.00 $195.00 Date Paid: Monday, April 28, 2014 Paid By: BRIAN A HARPER Pay Method: CREDIT CARD 02883B Printed: Monday, April 28, 2014 12:54 PM 1 of 1 CRWSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit Al 14 —0 t949 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670! Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: Address: 5 F Date ailed: Special Instructions: I/'r �j!'il� 7 Date Wanted:("t _ y a—efr P.m. Requester: Phone No: QApproved per applicable codes. Corrections required prior to approval. COMMENTS: Date: U ti REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Cali to schedule reinspection. INSPECTION RECORD Retain a copy with permit WI 4 o 41C1 N `E' 'ANN. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: e 1:. co 0op..)►.JEX. Type of inspection: 'tAi L-- Ad ress: Lg tl{abT Date Called: Special Instructions: (3 3 Date Wanted: a.m. Requester: Phone No: Approved per applicable codes. ECorrections required prior to approval. COMMENTS: SPECTION FEE EQUIRED. Prior io next inspection, fee must be d at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of nspectiQn: . Adjs / d Date Called: ` tD v ( (t'l7 Special Instructions: 3-d ` t[.. / 33 ��.1' e 1� t1' ti f �j Date Wanted: I�f 3.... ta,mi p.m. Requester: Phone No: /Approved per applicable codes. ['Corrections required prior to approval. COMMENTS: 1 Inspector: REINSPECTION FEE/REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: f . - INSPECTION RECORD Retain a copy with permit INS CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ',s►C.. e. G 3.1,1.-7'' Type.of Inspection: t' 1 io it Lt.- I.\ Address_; 5 Date Called: ii Special Instructions: Date Wanted: -7 3)-- lLf a.m. c'p:m. Requester: Phone No: Approved per applicable codes. DCorrections required prior to approval. COMMENTS: -P i l^ Arevt=?S lnsp ttor: I t_. REINSPECTI©N FEE SQUIRED. Prior to Text inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100/Call to schedule reinspection. V Dat7e: —3i-,� INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER Jt-air._ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: jff��n /mall-Q.. ii )1A.Y�i/ Type of Inspection: C/A2 ofti^G Address: / Suite #: `2 5 . / G sr Contact Person: Special Instructions: Phone No.: 3 k, Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: ,. ,1.4- Date: 4,/z7.j9/ Hrs.: / 42 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0049 PROJECT NAME: EDGE CONNEX DATE: 04/11/2014 SITE ADDRESS: 63425 S 116 ST, STE 113 Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued X Revision # 1 after Permit Issued DEPARTMENTS: BuilDivision ding Public Works n A'►v� N /A b [5 • I `� Fire Prevention Planning Division Structural Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/15/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 05/13/14 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0049 PROJECT NAME: EDGE CONNEX DATE: 02/20/2014 SITE ADDRESS: 3425 S 116 ST, STE 133 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: C )4 CP Building Division g. Public Works Fire Prevention Structural ■ n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 02/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/25/14 Approved Approved with Conditions Corrections Required (corrections entered in Reviews) Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED; Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PROJECT NAME: eI796 C PERMIT NO: MAW OP\ SITE ADDRESS: 1)14 ' t I l0 CDT ORIGINAL ISSUE DATE: I 01 REVISION LOG REVISION DATE RECEIVED STAFF INITIALSNIT ISSUED DATE STAFF S I UI i i W�� 0411A ..,,AA, Summary of Revision: kj:Q, (A C \v (V CU}pp-{J-0 eo AtLoW Q VVV Val fl A,l �0�-�i.�(r ci Received by:,�,2,4, 7 2�� ,fL", "" REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 04/11/2014 Plan Check/Permit Number: M14-0049 Response to Incomplete Letter # Response to Correction Letter # ,/ Revision # 1 after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: EDGE CONNEX Project Address: 3425 S 116TH ST SUITE #113 Contact Person: KEIR VONDRUSKA Phone Number: (206) 654-2137 Summary of Revision: Mechanically, the quantity and type of installed equipment to cool the Data hall did not change. The location of units was revised to match new space configurations as described above. And planning was done to allow for a higher ultimate quantity of cooling equipment to cool the larger UPS capacity. Of TUKWILA APR 112014 PEWIT CENTER Sheet Number(s): M0.1,M2.1,M2.2,M3.1,M7.1,M7.2 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: NIL ---Entered ' ntered in Permits Plus on -i 1 - (L/ H:\Applications\Forms-Applications On Linc\2010 Applications\7-2010 - Revision Submittal.doc Revised: May 2011 BURR COMPUTER ENVIRONMENTTS INC Page 1 of 2 Washington State Departinent of Labor & Industries BURR COMPUTER ENVIRONMENTS INC Owner or tradesperson BEAVER, CHARLES EMMETT III Principals BEAVER, CHARLES EMMETT III BEAVER, CHARLES EMMETT JRFRANK, TIMOTHY DAVIDBURR, RICHARD WAYNEBURR, KURT N (End: 09/06/2011)CARDER, DOUGLAS G (End: 09/06/2011) WA UBI No. 602 065 382 10400 RODGERS ROAD HOUSTON, TX77070 281-374-8644 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BURRCEI005PP Effective — expiration 11/06/2000 — 08/18/2015 Bond TRAVELERS CAS & SURETY CO Bond account no. 061S103188827BCM $12,000.00 Received by L&I Effective date 06/27/2002 05/24/2002 Insurance Hartford Fire Ins Co $1,000,000.00 Policy no. 6luengt2441 Received by L&I Effective date 06/28/2013 06/30/2011 Expiration date 06/30/2014 Savings No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602065382&LIC=BURRCEI005PP&SAW= 04/07/2014 MECHANICAL SYMBOLS MANUAL VOLUME DAMPER 0 M MOTORIZED VOLUME DAMPER OBDD E 4 BDD BACKDRAFT DAMPER i FD I.Con MIMI FD FIRE DAMPER SD mem mC4 isim SD SMOKE DAMPER i FSD ELAN M FSD COMBINATION FIRE/SMOKE DAMPER LSD SMOKE DETECTOR SD ci( CPI RISE IN DUCT ELEVATION of , o DROP IN DUCT ELEVATION RADIUS ELBOW MITERED ELBOW WITH TURNING VANES ? \- f 1 BRANCH CONNECTION TO MAIN ? ?r-11-1-1 - TRANSITION j1 ? ? DUCT WITH INTERNAL LINER j - . - n\ RETURN/EXHAUST DUCT UP, DOWN ` SUPPLY GRILLE WITH AIR QUANTITY `100 RETURN/EXHAUST GRILLE WITH AIR QUANTITY /1OOR/100E Q THERMOSTAT O HUMIDISTAT T..I TEMPERATURE/HUMIDITY SENSOR TEMPERATURE SENSOR T AIR-COOLED CONDENSING UNIT SCHEDULE (OFCI) U N ITTA CON01011 012 CON03021 CON N04022 CON05031 coNO 603 , z CON 13171 CON 4181 GON1701 MANUFACTURER. LIEBERT LIEBERT LIEBERT LIEBERT LIEBERT LIEBER. MODEL NUMBER MCL165E1A MCL165E1A • MCL165E1A MCL11:0E8A MCL11:0E8A PFH037A- 7 AREA SERVED DATA CENTER DATA CENTER DATA CENTER ! UPS ROOM UPS ROOM ISS CRAC UNIT SERVED CRA01000 CRA02000 CRA03000 CRAO:7000 CRA08000 CRA0900 AMBIENTTEMP. (°F) 10.5 105 ` 105 1.05 105 1.05 REFRIGERANTTYPE R-41OA. R-410A R-410A R-4.07C R-4O7C R-4077C: FAN QUANTITY (EACH) 3 3 3 2 2 1 FLA (EACH) 8.4 8.4 8.4 . :8.4 8.4 81 VOLTS/PHASE/HERTZ 460/3/60 460/3/60 460/3/6O: 460/3/60 460/3/6G 460/3/60 REMARKS 1,2,3,4 1,2,3,4 1,2,3,4. 2,4 2,4 2 REMARKS: 1. 18" SUPPORT LEGS. 2. FACTORY WIRED DISCONNECT SWITCH. 3. ONE(1) REFRIGERANT RECEIVER AND BRACKET ASSEM BLY FOR EACH 3-FAN CONDENSING UNIT SECTION. 4. ALARM TERMINAL CONNECTIONS. ECO NO -PHASE REFRIO.. PUMP MODULE SCHEDULE (OFCI). UNIT TAG ERRP01000 ERP02000 ERP0300.0 MANUFACTURER LIEBERT .LIEBERT • :LIEBERT MODEL NUMBER PR125AA6DD-0000 PR1.25AA6DD-0O00 PR125AA60D-0000 CRAC UNrrS:ERVED CRA01000 CRA02000 CRAO3000 PUMP TYPE REFRIGERANT REFRIGERANT REFRIGERANT QUANTITY of PUMPS 2 2 2 'HORSEPOWER 1.6 1:.:6: VOLTS/FHASE/HERTZ •48O/316U 480/3/60. 460/3/.B0 FULL LOAD: AMPS (FLA) 3:5 (EACH,) 3.5 (EACH) 3.5 (EACH) REMARKS ,23 . 1,2,3 1,2,3 NOTES: 1, DUAL PUMP CONFIGURATION WITH (1+1) REDUNDANCY. 2. 65,000 AMP SCCf 3, REFRIGERANT PUMP MODULE CONTROLLED BY ASSOCIATED CRAC ICOM CONTROL UPS ROOM VENTILATION CALCS CODE REFERENCE: 2006 IFC CHAPTER 6 SECTION 608.5 - STATIONARY LEAD -ACID BATTERY SYSTEM VENTILATION. SECTION 608.5 - LIMIT HYDROGEN TO LESS THAN 1% CONCENTRATION OF SPACE VOLUME. UPS ROOM : VOLUME: 1,270 SQ.FT. x 20' HIGH = 25,400 CU.FT. VOLUME. UPS ROOM IS DESIGNED TO CONTAIN 320 BATTERIES. HYDROGEN GASSING FROM MANUFACTURER'S DATA: - EACH BATTERY CELL HAS A HYDROGEN GASSING RATE OF 0.00134 CF/HR/CELL DURING FULL CHARGING (WORST CASE). - TOTAL GASSING RATE IS (320 CELLS) x (0.00134 CF/HR/CELL) = 0.423 CF/HR. - HYDROGEN GASSING AIR CHANGE IS (0.423 CF/HR) x (1 AC/25,400 CF) = 0.0000167 HYDROGEN AC/HR MAX. ALLOWABLE 1% HYDROGEN CONCENTRATION OF ROOM VOLUME IS (25,400 CF) x (0.01) = 254 CF. TIME TO PRODUCE 254 CF OF HYDROGEN IS (254 CF) / 0.423 CF/HR = 600.5 HRS = 25.0 DAYS. UPS RM EXHAUST SYSTEM: - UPS ROOM A EXHAUST SYSTEM EXHAUSTS (200 CF/M) x (60 M/HR) = 12,000 CF/HR » 0.423 CF/HR. - EXHAUST SYSTEM AIR CHANGE(AC) RATE IS (12,000 CF/HR) x (1 AC/25,400 CF) = 0.47 AC/HR » 0.0000167 HYDROGEN AC/HR. MARK SERVES TIP.E/DRIVE. CFM EXT. S.;P. (IN. VV. G;) HORSEPOWER -(WATTS) RPM (MAX.) SONES (MAX,.). VOLTS/PHASE/HERTZ MANUFACTURER SERIES MODEL NUMBER NOTES. FAN SCHEDULE EXF01:00:0: UIPS/ELECT RM ROOFIDIRECT .200. 0,30 1 /8 (53): 1., 213- 4.3 12011 /60 COOK ACE- 90C15DM 1.2 EXF02000 TOILET RMS ROOF/DIRECT 200 0.30 1 /8 (53): t,21:3 4.3 120/1160 - COOK ACE-D 90C15DM '1;3 • yNO V 2 1. PROVIDECONTROL. BIRDSCREEN, GRAVITY BACKDRAFT DAMPER, 12 HIGH ROOF CURB, AND FAN SPEED 2, FAN SHALL RUN CONTINUOUSLY. 3. FAN CONTROLLED THRU RESTROOM LIGHT SWITCH. REFER TO ELECT. MECHANICAL SYMBOLS PUMPED CONDENSATE DRAIN ?-- PCD-? REFRIGERANT HOT GAS -RHG? REFRIGERANT LIQUID ? RL -? PIPE UP 01 ? (w I d PIPE DOWN cam--? (' 1 ci CAP C ? I d T 90' ELBOW ? 1 d RISE OR DROP IN ELEVATION c4C-C+-? h I( IC 11 d I TEE OR BRANCH CONNECTION ? ,T, CONNECT TO EXISTING ABBREVIATIONS E - EXISTING TO REMAIN PCD - PUMPED CONDENSATE DRAIN R - RELOCATE OA - OUTSIDE AIR D - DEMOLISH EA - EXHAUST AIR AFF - ABOVE FINISHED FLOOR RA - RETURN AIR OBD - OPPOSED BLADE DAMPER SA - SUPPLY AIR BDD - BACKDRAFT DAMPER SWR - SIDEWALL REGISTER CRAC - COMP. RM. A/C UNIT UNO - UNLESS NOTED OTHERWISE RHG - REFRIGERANT HOT GAS CFM - CUBIC FEET PER MINUTE RL - REFRIGERANT LIQUID OFCI - OWNER FURNISHED, CONTRACTOR INSTALLED. OWNER FURNISHED ITEMS ARE PURCHASED AND WARRANTED AS STATED IN THESE DOCUMENTS BY BURR COMPUTER ENVIRONMENTS, INC. REVIEWED FOR CODE COMPLIANCE APPROVED APR 16 201k City of u ila BUILDING VISION MECHANICAL GENERAL NOTES 1. REFER TO THE SPECIFICATIONS FOR ALL MATERIALS, MANUFACTURERS, METHODS OF CONSTRUCTION AND INSTALLATION PROCEDURES UNLESS NOTED OTHERWISE IN THIS SET OF PLANS. 2. THE CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE AND BECOMING FAMILIAR WITH THE EXISTING BUILDING AND CONDITIONS WITHIN THE SCOPE OF THIS PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH OTHER TRADES PRIOR TO FABRICATING AND INSTALLING THE MECHANICAL SYSTEMS. 3. THE APPROXIMATE LOCATIONS OF MECHANICAL ITEMS ARE SHOWN ON THE PLANS. THESE PLANS ARE NOT INTENDED TO GIVE COMPLETE AND ACCURATE DETAILS IN REGARD TO LOCATION OF DEVICES, EQUIPMENT, ETC.. EXACT LOCATIONS SHALL. BE DETERMINED BY ACTUAL MEASUREMENTS TAKEN AT THE BUILDING AND IN COORDINATION WITH EXISTING CONDITIONS AND ALL OTHER TRADES. 4. ALL WORK SHALL COMPLY WITH PERTINENT STATE AND LOCAL CODES. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS, FEES, AND INSPECTIONS. 5. WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER AND SHALL INCLUDE ALL LABOR AND MATERIALS ESSENTIAL TO PROVIDE COMPLETE FUNCTIONING SYSTEMS AS DESCRIBED IN THE CONTRACT DOCUMENTS. IN CASES OF DOUBT AS TO THE WORK INTENDED, OR IN THE EVENT OF NEED FOR EXPLANATION, THE CONTRACTOR SHALL REQUEST ADDITIONAL INFORMATION FROM THE ARCHITECT/ENGINEER. WORK SHALL NOT PROCEED WITHOUT CONFIRMATION BY THE ARCHITECT/ENGINEER. 6. THE CONTRACTOR IS REQUIRED TO PROVIDE SUBMITTALS FOR ALL MATERIALS AND EQUIPMENT TO BE INSTALLED WITHIN THE SCOPE OF THIS PROJECT. 7. THE CONTRACTOR SHALL WARRANT THE INSTALLATION OF THE EQUIPMENT PURCHASED BY THE OWNER FOR ONE YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION AS DETERMINED BY THE OWNER. 8. THE CONTRACTOR SHALL WARRANT THE EQUIPMENT AND INSTALLATION OF THE EQUIPMENT PURCHASED BY THE CONTRACTOR FOR ONE YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION AS DETERMINED BY THE OWNER. 9. DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 10. GRILLES, REGISTERS, AND DIFFUSERS SHALL BE AS PER THE SCHEDULE. FRAME TYPE OF EACH DEVICE SHALL BE DESIGNED FOR THE CEILING TYPE IN WHICH IT IS INSTALLED. 11. COORDINATE THE LOCATION OF ALL AIR DISTRIBUTION DEVICES WITH THE ARCHITECTURAL REFLECTED CEILING PLAN, INCLUDING LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS, AND SMOKE DETECTORS. 12. MECHANICAL EQUIPMENT AND DEVICES (VALVES, DAMPERS, TERMINAL UNITS, ETC.) INSTALLED ABOVE INACCESSIBLE CEILINGS SHALL HAVE ACCESS DOORS INSTALLED IN THE CEILING TO ALLOW FOR SERVICE. THE MECHANICAL CONTRACTOR SHALL FURNISH THESE ACCESS DOORS FOR THE GENERAL CONTRACTOR TO INSTALL THE MECHANICAL CONTRACTOR SHALL COORDINATE THE LOCATION OF THESE DOORS WITH THE ARCHITECT TO BEST ALLOW FOR SERVICE AND ARCHITECTURAL APPEARANCE. 13. THE CONTRACTOR SHALL PROVIDE TEMPORARY FILTER MEDIA AS REQUIRED FOR THE OPERATION OF CRAC'S, RTU'S DURING CONSTRUCTION. THESE FILTERS ARE TO BE CHANGED AS NEEDED THROUGHOUT THE CONSTRUCTION PROCESS. THE UNITS SHALL NOT RUN WITHOUT THESE FILTERS INSTALLED. THE CONTRACTOR SHALL INSTALL THE FILTERS PROVIDED WITH THE UNIT PRIOR TO THE AIR BALANCE OF EACH UNIT. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 14. VERIFY LOCATION OF THERMOSTATS AND SPACE TEMPERATURE SENSORS WITH THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. INSTALL THERMOSTATS AND SENSORS AT THE SAME CENTERLINE ELEVATION AS LIGHT SWITCHES. 15. ALL MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME -SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE -DEVELOPED RATING OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH THE TEST FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, ASTM E-84-91A AND ANSI/UL 723-86. 16. MECHANICAL CONTRACTOR TO PROVIDE AIRSIDE TEST AND BALANCE (NEBB OR AABC) FOR ALL AFFECTED HVAC SYSTEMS, INCLUDING ALL AIR DEVICES, AIR TERMINAL UNITS AND ROOFTOP AIR CONDITIONING UNITS WITHIN THE SCOPE OF WORK. REFER TO SHEET M2.1 FOR AIR QUANTITIES. CRAC UNIT SCHEDULE (OFCI) UNIT NIT TAG CRA01O00 CRA02000 CRA0300D CRA08000 CRA09000 LIEBERT MODEL NUMBER DAI5ODP1A VS042ADA000 MM036E7A00D AREA SERVED DATA CENTER UPS RM ISS .............. . TYPE AIR-COOLED AIR-COOLED AIR-COOLED UNIT CONFIGURATION! DOWNFLOW U P FLOW DOWNFLOW SUPPLY FAN SUPPLY AIR (CFM) 18,000 6,300 1,250 MOTOR �UANTITY Q. 3 EC 1` 1 EXT. SP(IN. W.G.) 0.2 0.2 0.3 HP (EACH) 3.7 7.5 0.5 COOLING COIL EAT DBJW B CF) 75/61 75/61 75/61 LAT DBIWB (°F) 55/54 55/54 55/54 SENSIBLE COOLING CAPACITY - KW (MBH) 134 (457) 36.4 124.2- TOTAL COOLING CAPACITY - KW (MBH) 134 (457) 42 (143.3) 955 (32.5) FACE VELOCITY (FPM) 320 368 394 HUMIDIFIER. TYPE NFRARED NA NA CAPACITY ;(LBS/H R) 22.0 NA NA ELECTRIC REHEAT kW `300 NA NA STEPS 3 NA NA ELECTRICAL FLA (F LA W/ HUM & `REHEAT L:O.CKE D OUT) 102.7 (91.1) 39.2 (NA) 1.4 (NA) V/PH/HZ: 460/3/60 460/3/60 460/3/60 REMARKS3,5,10,12,17,18, 1,2,3,4,5,6,7,8,9,10,1 2,13,14,15,16 ;3,45,69,10,11,12,14, -15,16,17 9 REMARKS: 1:;. ELECTRICALLY COMMUTATED FAN MOTORS: 2.R-410A REFRIGERANT. 3. 4" .FILTERS, MERE-8 RATING. 4: LT460-Z25 LEAK SENSOR WITH 25 FT LEAK DETECTION CABLE. FIELD INSTALLED. 5. FACTORY INSTALLED DUAL FLOAT CONDENSATE PUMP, 6. ADVANCED MICROPROCESSOR -BASED TEMPERATURE AND HUMIDITY CONTROLS. 7. ACCOMPANIED BY RESPECTIVE MICRO -CHANNEL AIR-COOLED CONDENSER AND ECONOPHASE REFRIGERANT PUMP PACKAGE. REFER TOACCU'SCHEDULE. 8. 30" HIGH FLOOR STAND. 9. 65,000 AMPS SHORT CIRCUIT CURRENT RATING. 10. NON -LOCKING DISCONNECT SWITCH. 11,ACC.OMPANIED: BY RESPECTIVE MICRO -CHANNEL AIR-COOLED CONDENSER REF ERTOACCU SCHEDULE. 12. LOW VOLTAGE TERMINAL PACKAGE. 13. REHEAT AND HUMIDIFIER LOCKOUT. 14. UNITY COMMUNICATION NE11NORKING' CARD. 15. SMOKE SENSOR WITH UNIT ALARM AND SHUTDOWN, INCLUDING SUPERVISION CONTACTS. 16. iCOM CONTROL WITH LARGE DISPLAY: 17. R-407C REF RIGE RANT. 18. AIR DISTRIBUTION PLENUM 19. WALL MOUNTED UNIT CONTROLLER SEPARATE PERMIT REQUIRED FOR: ❑ Mechanical Electrical D Plumbing Gas Piping City of Tukwila BUILDING DIVISION MECH MATERIAL SPECIFICATIONS . REFRIGERANT PIPING UP THROUGH 2": DRAWN TEMPER COPPER TUBING ASTM B 88 TYPE "L" WITH WROUGHT COPPER FITTINGS (ASTM B16.22). SILVER SOLDER ALL JOINTS WITH AWS A5.8 CLASSIFICATION B AG-1 SILVER SOLDER. UTILIZE NITROGEN PURGE WHILE BRAZING. 2. REFRIGERANT VALVES: A) SHUT OFF VALVE UP THROUGH 2": 1) STRAIGHT THROUGH BALL VALVES: VALVE RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. FULL PORT, FORGED BRASS OR BRONZE BODY AND BONNET COVER, CHROME PLATED BRONZE BALL PTFE, OR TFE SEATS, AND WITH SOLDER END CONNECTIONS. 2) PACED -ANGLE VALVES: RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. FORGED BRASS OR BRONZE BODY, FORGED BRASS SEAL CAPS .WITH COPPER GASKET, BACK SEATING, RISING STEM AND SEAT, MOLDED STEM PACKING, AND WITH SOLDER END CONNECTIONS. B) SERVICE VALVES: RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. FORGED BRASS BODY WITH COPPER STUBS, BRASS CAPS, REMOVABLE VALVE CORE AND WITH SOLDER END CONNECTIONS. 3. REFRIGERANT SPECIALTIES: A) MOISTURE/LIQUID INDICATORS: RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. ALL BRASS BODY WITH REPLACEABLE, POLISHED, OPTICAL VIEWING WINDOW WITH COLOR CODED MOISTURE INDICATOR AND WITH SOLDER END CONNECTIONS. B) STRAIGHT THROUGH OR ANGLE TYPE STRAINERS: RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. FORGED BRASS OR STEEL BODY WITH STAINLESS STEEL WIRE OR BRASS REINFORCED MONEL SCREEN. 80 TO 100 MESH IN LIQUID LINES UP TO 1Y$" IN SIZE, 60 MESH FOR LARGER LIQUID LINES, AND 40 MESH IN SUCTION LINES. PROVIDE SCREWED CLEAN OUT PLUG AND SOLDER END CONNECTIONS. C) PERMANENT FILTER DRIERS: RATED FOR 350 PSIG WORKING PRESSURE AND 225'F WORKING TEMPERATURE. STEEL SHELL AND WROUGHT COPPER FITTINGS FOR SOLDER END CONNECTIONS. MOLDED FELT CORE SURROUNDED BY DESSICANT. 4. PIPING INSULATION: A) REFRIGERANT PIPING (HOT GAS AND LIQUID FOR DATA CENTER DSE SYSTEMS): 1/2" THICK CLOSED -CELL FLEXIBLE ELASTOMERIC. ALUMINUM JACKET WITH PRE -MOLDED FITTINGS (OUTDOOR ONLY). B) REFRIGERANT PIPING (HOT GAS FOR UPS RM DS SYSTEMS): 1/2" THICK CLOSED -CELL FLEXIBLE ELASTOMERIC. ALUMINUM JACKET WITH PRE -MOLDED FITTINGS (OUTDOOR ONLY). C) CONDENSATE DRAIN: Y" THICK FIBERGLASS WITH ASJ. SEAL VAPOR BARRIER. PROVIDE PRE -MOLDED FITTINGS. 5. ALL DUCTWORK SHALL BE CONSTRUCTED OF NEW LOCK FORMING QUALITY GALVANIZED SHEET METAL IN ACCORDANCE WITH THE LATEST SMACNA STANDARDS TO THE 2 W.G. PRESSURE CLASSIFICATION. ALL LONGITUDINAL SEAMS AND TRANSVERSE JOINTS SHALL BE SEALED PER SMACNA DUCT SEALING REQUIREMENTS SEAL CLASS "B". SEAL WITH A WATER BASED ADHESIVE SEALER DESIGNED FOR MEDIUM VELOCITY DUCT SYSTEMS. SEALER SHALL BE HARDCAST, INC., "IRON GRIP WATER BASE DUCT SEALANT #601." DUCTWORK SHALL BE ?DUNG AS HIGH AS POSSIBLE FROM THE BUILDING STRUCTURE WITH HANGER ASSEMBLIES IN ACCORDANCE WITH "SMACNA" REQUIREMENTS. THE CONTRACTOR SHALL PROVIDE ADDITIONAL RISES, DROPS, AND OFFSETS IN -DUCTWORK AS REQUIRED. 6. ALL INSULATION SHALL HAVE A COMPOSITE (INSULATION, JACKET OR FACING, AND ADHESIVE USED TO ADHERE FACING OR JACKET TO INSULATION) FIRE AMD SMOKE HAZARD RATING (AS TESTED BY PROCEDURE ASTM E84, NFPA 225, AND UL 273) NOT EXCEEDING A FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. 7. ALL EXPOSED SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL NOT BE INSULATED. ALL CONCEALED SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH 1 1/2" THICK DUCT WRAP, 3/4 LB/CU.FT. INSULATION. INSULATION SHALL HAVE A FACTORY APPLIED FOIL-SKRIM-KRAFT FACING CONSISTING OF 0.35 MIL. ALUMINUM FOIL REINFORCED WITH GLASS YARN MESH AND LAMINATED TO 40 POUND CHEMICAL TREATED, FIRE RESISTANT KRAFT. OVERLAP ALL SEAMS, STAGGER LONGITUDINAL SEAMS. SEAL SEAMS WITH 4" WIDE PRESSURE SENSITIVE TAPE AND OUTWARD CLINCHING STAPLES. USE SPEED CUP PINS ADHERED TO DUCT SURFACES OVER 18" IN WIDTH ON 16" CENTERS AND MAX. 3" FROM INSULATION SEAMS. APPLY BRUSH ON VAPOR RETARDANT MASTIC OVER TAPE EDGES, PINS, AND TEARS IN VAPI: BA" k ... ON T M C 8. MECHANICAL CONTRACTOR SHALL PROVIDE 5 DAYS OF ASSISTANCE FROM STARTUP TECHNICIAN OR QUAIJFIED PERSONNEL TO ASSIST COMMISSIONING AGENT DURING COMMISSIONING PERIOD. AIR DEVICE:7SCHEaULE, MARK MFR. & MODEL TYPE REMARKS. TITUS TMSA-AA LOUVERED SUPPLY AIR GRILLE -ALUMINUM:CONSTRUCTION LAY IN FRAME, FULL FACE, WHITE FINISH,- REFER Tt NLET SIZING CHART FOR NECK SIZE. 1 1 TITUS PAR PERFORATED RETURN AIR GRILLE ALUMINUM CONSTRUCTION, TYPE-3 LAY -IN 'FRAME., WHITE FINISH, 22x22 NECK. TITUS 301 FL 'SIDEWALL SUPPLY AIR GRILLE ALUMINUM CONSTRUCTION,.3/4" BLADE SPACING, ALUMINUM FINISH., DOUBLE DEFLECTION WITH FRONT BLADES: PARALLEL TO LONG DIMENSION.: 1 TITUS 350 FL. SIDEWALL EXHAUST AIR GRILLE ALUMINUM CONSTRUCTION, 3/4" BLADE SPACING, ALUMINUM .FINISH, DOUBLE DEFLECTION WITH FRONT BLADES PARALLEL TO LONG DIMENSION. NOTES: 1. STANDARD WHITE FINISH 2. ,PROVIDE.SQUA.RE TO ROUND NECK TRANSni N FOR CON:NECTiON TO:FLEXDUCT FAN COIL UNIT - CONDENSING UNIT SCHEDULE FURNACE MARK MFG. MODEL # OA CFM BLOWER HEATER KW/STEPS ELECTRICAL ACC CFM *E.S.P. HP VOLT/PH MCA MOCP FCU01000 TRANE BCHC036B2 130 1200 0.5 1/2 8/2 208/1 53.4 60 T FCU02000 TRANE BCHC036B2 150 1160. 0.75 1/2 8/2 208/1 53.4 60 T FCU03000 TRANE BCHC036B2 50 1350 0.5 1/2 8/2 208/1 53.4 60 T FCU04000 TRANE BCHC054B2 50 2000 0.5. 1/2 8/2 208/1 53.4 60 T EVAPORATOR -CONDENSING UNIT MARK MFG. CLG. CAPACITY EVAPORATOR CONDENSING UNIT LBS AMB TEMP SENS TOTAL CFM EDB EWB APD MODEL # V/PH MCA MOCP CON 161 10 TRANE 27.2 31.7 1200 76.6 62.9 - 4TTA3042 208/3 18 30 200 95 CON17120 TRANE 29.8 39.0 1160 77.8 64.8 - 4TTA3048 208/3 18 30 210 95 CON 18130 TRANE 29.8 39.0 1350 77.8 64.8 - 4TTA3048 208/3 18 30 210 95 CON19140 TRANE 43.5 55.5 2000 75.0 63.0 - 4TTA3060 208/3 21 35 230 95 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division_ NOTE Revisions will require a new plan submittal 1 and may include additional plan review fees. MECHANICAL DRAWING INDEX NUMBER DRAWING TITLE MO.1 MECHANICAL SYMBOLS, NOTES, SPECIFICATIONS, & SCHEDULES M1.1 MECHANICAL DEMOLITION PLAN M2.1 MECHANICAL PIPING PLAN - LEVEL 1 :.- RECEIVED .,. M2.2 MECHANICAL PIPING PLAN - ROOF CITY OF TUKWILA M3.1 APR 1 1 201If MECHANICAL DUCTWORK PLAN M7.1 MECHANICAL DETAILS PERMIT CENTER M7.2 MECHANICAL SECTIONS AND DETAILS 1 00 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 CD CS) LLI 0 0 w 0 ISSUES & REVISIONS Date Description 02/17/2014 ISSUE FOR PERMIT 03/28/2014 oftIta 1c0 PY Perninto, Mit-cO Li cl_ Plan review wad is subjedto wore and omissions. the violation of any Worded code oT Tame. Receipt Dar City OrItda BUILDING DIVISION REVISION NOJ - - SHEET NILE MECHANICAL SYMBOLS, NOTES, SPECS, & SCH. DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEET NO. MO.1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. EXISTING ON GRADE EXISTING DOCK HIGH (-48") WAREHOUSE OFFICE ❑FFICE ❑FFICE ❑FFICE EQUIP. DGP. I L - I - --II la �5 =LI PRINT/C❑PY RECEPTI❑N MECHANICAL DEMOLITION PLAN SCALE' 1/8•-1-0• MECHANICAL LEGEND GEN. ❑FFICE TO BE REMOVED TO REMAIN ❑FFICE GENERAL NOTES 1. REFER TO SHEET MO.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REMOVE ALL DUCTWORK, TERMINAL BOXES, AND DIFFUSERS WITHIN SCOPE OF WORK. KEYED NOTES 01 DEMO ALL EXISTING DUCTWORK IN THIS AREA. 0DEMO DUCTWORK THRU ROOF TO EXISTING ROOF TOP UNIT ABOVE. DEMO ROOF 0 TOP UNIT. CAP AND SEAL CURB. 03 DEMO EXHAUST FAN ON ROOF AND ALL CORRESPONDING DUCTWORK. CAP AND SEAL CURB. KEYPLAN AREA OF WORK REVIEWED FOR CODE COMPLIANCE APPROVED APR 16 2014 City of Tukwila BUILDING DIVISION Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 >.< CD O a w U 0 w 0 LLJ 1 oo c 65 T C F- f ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT A03/28/2014 ADDENDUM 1 SHEET TITLE MECHANICAL DEMOLITION PLAN DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEET NO. M1.1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 13 LOADING DOCK L115 J 630 SF FCU03000 14 PRE -AC: II I ON L116J GEN01000 (600KW) COLD AISLE. I--1--J--I--I--I--I--I 202. 200. 200. z00. 200. 2^0. ,00. I I I I d I 17 1 1 I_-1--1--J_ 1--1-_1-- HOT AISLE 1--I--I- 1--I--I--I--1 100. 100. 110. 130. 100. 100. 100. 1 = -g_ 1 7 1 6 1 5 1 4 1` I 21 11--,z I_-1--J--J_ _1_-J_-1--1 HOT AISLE Cole AIS_E SHELL I--177 119-I--1--1--I 200. 200-1 ___. 200. 200. .,00. 200. I N 7 1 3283 SF 4 1 - 1 2 1 1 - o I I 1 I J I I - o HOT AISLE MO. 100. 100. 130. 100. 1 71 6 1 1 41 I--1- HOT AISLE ,-�-- 11111 11111 11111 GEN020C0 (600KW LikPIDIPJC / 1J pg ATS ATS 30 0 2000 MMR2 L1o1 J 234 SF C0N15091 FU :•_ MECHANICAL YARD L122J 2784 SF CON14081 CON13071 UPSB1000 BATT. BATT. BATT. i BATT. i BATT. BATT. UFSA1000 PDUD1000 PDUC1000 PDUB1000 PDUA1000 CD CL CD 1-1/2'PCD T I 400.1400 11,2 L J 1- T 1500.1500.1- 1121 L-L r-T 1700.1700.1 11121 L� I I 800.1800.1: 1 1 2 1 , L� 1 200 200 00 200 200 200 52oo. 62oo. 7200. 8200. 920c . -Rio 6 7 8 9 10 11 MECHANICAL PIPING PLAN SCALE. 1/8•-1-O' T 7 �.1500.1 T 0.1700 T 0.1800.1 16 I *07000 3/4"PCD MMR1 L 109 194 SF LEVEL 1 MECHANICAL LEGEND H HOT GAS REFRIG. PIPING LIQUID LINE REFRIG. PIPING PUMPED CONDENSATE PIPING ---- HUMIDIFIER WATER PIPING - 18 18 REVIEWED FOR CODE COMPLIANCE APPROVED APR 16 20i4 City of Tukwila BUILDING DIVISION COR" IDOR 8 102 SF LANDING II I1 11 II ESTIBULE L 111 J 62 SF 19 GENERAL NOTES 1. REFER TO SHEET MO.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS M7.1 AND M7.2 FOR INSTALLATION DETAILS AND SECTIONS. 3. ALL EQUIPMENT AND PIPING SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH LOCAL CODES. KEYED NOTES 01 06 07 ROUTE 3/4"PCD AND (2) SETS OF REFRIG HOT GAS AND LIQUID LINES DOWN WALL TO CONNECT TO CRAC CONNECTIONS. REFER TO SECTION ON M7.2. ROUTE REFRIG HOT GAS AND LIQUID LINES UP THROUGH ROOF PENETRATION AND ROOF HOOD TO CONDENSING UNITS ON ROOF. COORDINATE ROUTING WITH ELECT CONTRACTOR FOR CONTROL AND POWER CONDUITS., REFER TO M2.2 FOR CONTINUATION. REFER TO M7.1 FOR ROOF HOOD DETAIL. PROVIDE 3/4"PCD VALVED AND CAPPED FOR INSTALLATION OF FUTURE CRACS. CONNECT 3/4"PCD, AND REFRIG HOT GAS AND LIQUID LINES TO CRAC UNIT CONNECTIONS. CONNECT REFRIG HOT GAS AND LIQUID LINES TO ECONOPHASE REFRIG PUMP UNIT. REFER TO SECTION ON M7.2. CONNECT REFRIG HOT GAS AND LIQUID LINE AND CONDENSATE TO FAN COIL UNIT ABOVE CEILING. ROUTE 2"PCD DOWN TO FLOOR DRAIN. 08 SLOPE PCD 1/8 PER FOOT TOWARDS FLOOR DRAIN. 09 ROUTE (2) SETS OF REFRIG HOT GAS AND LIQUID LINES DOWN ALONG EXTERIOR WALL TO CONDENSING UNIT. ooq AREA OF WORK RECEIVED OF TUKWILA R i 1 2014 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 C LLJ 0) J ISSUES &REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT 03/28/2014 ADDENDUM 1 C SHEETTITLE MECHANICAL PIPING PLAN - LEVEL 1 DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEETNO. KEYPLAN PERMIT CENTER PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. J r---� (FUT.)CON15141 j i --, 1 1 i- 1 - A f( s~ I I SiiC:� I 1 J (FUT.)CON 16142 f 1(;iii llll\ (f 11111 J (FUT.)CON17131 FUT.)C0N20122 r ‘,7"-:-c I IN+ - fr tii;�1 fr J (FUT)CON21111 1i111 I (d6 ti FUT. CON22 2 CON30®31 CON31041 EXF01000 CON01011 CON02012 CON03021 CON04022 CON05031 CON06032 (FUT)CON 13101 (FUT.)CON 14102 MECHANICAL PIPING PLAN - ROOF SCALE. 1/89■1'-0• (FUT.)CON07041 (r ;c \ (r ;;►;l n fr „►;1 I I L — — J (FUT)CON08042 II (1 )11 II (FUT.)CON 11061 rir ` I(l ; \1 I I L J (FUT)CON12062 —Ta fir ;' f �r 1' ` MECHANICAL LEGEND H HOT GAS REFRIG. PIPING LIQUID LINE REFRIG. PIPING ---- PUMPED CONDENSATE PIPING HUMIDIFIER WATER PIPING — EXFO2C00 CON28021 CON27C11 CON26151 GENERAL NOTES 1111111111/ 1. REFER TO MO.1 FOR SPECIFICATIONS, SYMBOLS, AND LEGENDS. 2. COORDINATE ALL ROOF PENETRATIONS WITH STRUCTURAL ENGINEER AND BASE BUILDING WARRANTIED ROOFING SUBCONTRACTOR. 3. ALL REFRIGERANT PIPING SHALL BE INSULATED AND WITH ALUMINUM JACKET. KEYED NOTES 01 02 03 04 05 06 L KEYPLAN MECH CONT TO PROVIDE AND GEN CONT TO INSTALL PIPING ROOF HOOD. COORDINATE SIZE OF ROOF PENETRATION AND ROOF HOOD WITH ELECT CONTRACTOR. REFER TO DETAIL ON M7.1. ROUTE INSULATED REFRIGERANT HOT GAS AND LIQUID PIPING DOWN THROUGH ROOF PENETRATION AND ROOF HOOD. REFER TO M2.1 FOR CONTINUATION. CONNECT REFRIGERANT HOT GAS AND LIQUID PIPING TO NEW CONDENSING UNIT AND REFRIGERANT RECEIVER CONNECTIONS. REFER TO MANUFACTURER PIPING SCHEMATIC AND INSTALLATION INSTRUCTIONS. CONNECT REFRIGERANT HOT GAS AND LIQUID PIPING TO NEW CONDENSING UNIT. REFER TO MANUFACTURER PIPING, SCHEMATIC AND INSTALLATION INSTRUCTIONS. ROUTE REFRIGERANT PIPING ON DURA—BLOK MODEL DB630 ROOFTOP PIPE SUPPORT. REFER TO SPECIFICATIONS FOR SPACING. 8"0 OUTSIDE AIR DUCT UP THROUGH ROOF TO ROOF CAP WITH BIRDSCREEN AND 12" PREFAB INSULATED ROOF CURB. COORDINATE WITH GEN. CONT. AND WARRANTIED ROOFING SUBCONTRACTOR. 10x10 EXHAUST AIR DUCT UP THROUGH ROOF TO ROOF MOUNTED EXHAUST FAN. MECH CONT TO PROVIDE AND GEN CONT TO INSTALL ROOF CURB. GEN CONT TO PROVIDE AND INSTALL EQUIPMENT ROOF CURBS. AREA OF WORK REVIEWED FOR CODE COMPLIANCE APPROVED APR 16 2014 City of Tukwila BUILDING DIVISION R : CEI D CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER LCD CD c D: EDCSEA01 W H U) r ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT A03/28/2014 ADDENDUM 1 SHEETTITLE MECHANICAL PIPING PLAN - ROOF DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEETNO 2.2 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. (13 0 12x8 LOAD G 300 O DO (TYP.2) FCU03000 II II II II II II II II II • 5 --J • dll III III L III III III III III III III z-zi-__J -1 II II II II LU 0 FCU03000 BFP 116 89 SF 14 14 15 16 17 GEN01000 (600KW) GEN020 0 (600KW1 LaI® AMIE MBCC1000 I UPSC1000 1 BATT. I L —1- — — rr LL O w 0 0 CO 111 CRA08000 111 MMR2 L101 234 SF 15) Fr CO MECHANICAL YARD L122 C0N15091 (FUTURE) 2784 SF EXF01000 ON ROOF LL 0 0 0 w CD CON14081 CO CON13071 rr=- LI- 0 0 c0 w CD 0 c0 n I — -TDSC 1 MDPCI IIATSC 1M1000 I 10001 111000 L_—J MDPDI 1 [MDSD1 ATSD I 1000 u L1000 1000 FRONT FKUNI 1J 100. 100. 1 D0. 100. 100. 100. 100. 100. 100. 100. 100. 101 1 2 3 4 5 6 7 8 9 10 11 12 ( HOT AISLE COLD AISLE 800. 800. 800. 8 9 10 HOT AISLE — 700. 1700. 11 1 12 700. 13 700. 14 700. 15 (17 MECHANICAL DUCTWORK PLAN SCALE' 1/8•-1'-0• MMR1 L109 194 SF 18. RR 113 58 SF RR 14x14 iiiiiiii I I niimum ■L o��Ei���� 11110 8"OA DUCT `lli 16x12 OA FCU10se 150 258 SF %tii 66' 18) STORAGE L110.2 47 SF VEST =ULE 1nIP 62 SF REVIE FOR CODE COMPLIANCE APPROVED APR 16 2014 City of Tukwila BUILDING DIVISIO 19 1 2 INLET SIZING CHART ROUND NECK SIZE CFM RANGE 6"0 0 - 120 8"0 121 - 220 10"0 221 - 360 12"0 361 - 560 14"0 561 - 800 GENERAL NOTES 1 REFER TO SHEET MO.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEET M7.2 FOR DETAILS AND SECTIONS. 3. ALL ROOF PENETRATIONS SHALL BE COORDINATED WITH STRUCT. ENG. ALL ROOF WORK TO BE DONE BY GC WITH WARRANTIED ROOFING SUBCONTRACTOR. Y-DJOTES 01 ROUTE 10x10 EXHAUST DUCT UP THROUGH ROOF TO ROOF MOUNTED EXHAUST FAN. MC TO PROVIDE ROOF CURB. GC TO INSTALL ROOF CURB. 05 06 07 ROUTE 8" DIA. OUTSIDE AIR DUCT UP THROUGH ROOF TO MUSHROOM CAP OUTSIDE AIR INTAKE WITH 12" INSULATED ROOF CURB AND BIRDSCREEN. PROVIDE MOTORIZED DAMPER TO OPEN WHEN UNIT IS 'ON' AND CLOSED WHEN UNIT IS 'OFF'. TWO(2) 56x36 FRAMED RETURN AIR OPENINGS BY OTHERS. PROVIDE AND INSTALL 1-1/2" ANGLE IRON FRAME WITH 3/4" EXPANDED METAL TYPE GRATE MOUNTED ABOVE. DATA CENTER CEILING IN FRAMED OPENINGS FOR ALL NEW AND FUTURE CRACS. COORDINATE LOCATIONS OF NEW AND FUTURE CRAC RETURN AIR OPENINGS WITH GEN CONT. REFER TO DETAIL 03/M7.2. TWO(2) 56x24 FRAMED SUPPLY AIR OPENINGS BY OTHERS. PROVIDE. AND INSTALL SHEET METAL BLANK OFF PANEL AT ALL FUTURE CRAC OPENINGS. COORDINATE LOCATIONS OF NEW AND FUTURE CRAC SUPPLY AIR OPENINGS WITH GEN. CONT. REFER TO DETAIL 03/M7.2. PROVIDE AND INSTALL 12x8 SUPPLY AIR OPENING WITH GRILLE AND FIRE DAMPER ABOVE DATA CENTER CEILING. PROVIDE AND INSTALL 12x8 PRESSURE RELIEF RETURN AIR OPENING WITH GRILLE AND FIRE DAMPER ABOVE DATA CENTER CEILING. GENERAL CONTRACTOR .TO PROVIDE FLOOR SUPPLY GRILLES AND CEILINGRETURN GRILLES IN DATA CENTER AREA. KEYPLAN AREA OF WORK = EIVED CITY OF TUKWILA Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 U 5 W cn 0 0 LLJ LLI ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT 03/28/2014 ADDENDUM 1 MECHANICAL DUCTWORK PLAN sHEETTITLE DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEET NQ M3.1 APR 1 1 2014 PERMIT CENTER PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. ROOF CLAMP SHOULDER BOLT DURA-BLOK MODEL DB6 ROOF PIPE SUPPORT WITH RUBBER BASE. NO ROOF PENETRATION REQUIRED. COORDINATE LENGTH OF SUPPORT WITH REFRIG PIPING AND ELECT CONDUIT REQUIREMENTS. REFRIGERANT PIPE PIPE INSULATION CUSHION NOTES: 1) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. 2) SPACING OF SUPPORTS PER SPECIFICATIONS. SUPPORT SPACING SHALL BE BASED ON THE SMALLEST DIAMETER PIPE SUPPORTED BY THE RACK. ROOF PIPE SUPPORT NOT TO SCALE. MIN. 4" CLEARANCE FROM PIPE TO TOP OF CURB; MIN. 2" BETWEEN PIPES SHEET -METAL FLASHING RECEIVER 2x6 MIN. WOOD NAILER ATTACHED TO SUBSTRATE; OVERALL THICKNESS TO MATCH INSULATION SINGLE -PLY ROOF MEMBRANE ROOF PENETRATION NOT TO SCALE UNISTRUT STAINLESS STEEL ENCLOSURE WITH REMOVABLE TOP. CROSSBREAK OR SLOPE FOR DRAINAGE. INSTALL 1" FOAM BOARD INSULATION TIGHT TO INSIDE WALLS OF ROOF PENETRATION STAINLESS STEEL COLLAR SLOPE PIPES DOWN AND AWAY FROM HOOD REMOVABLE STAINLESS STEEL COUNTER -FLASHING ADHERED MEMBRANE FLASHING SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM) GASKETED FASTENERS (MINIMUM 2 PER SIDE) BONDING ADHESIVE SEAM PLATES AND FASTENERS COVER BOARD AND, THERMAL INSULATION ROOF DECK DEMISING WALL OR RATED PARTITION SHEETMETAL SLEEVE ESCUTCHEON PLATE ON PIPES EXPOSED WITHIN ROOMS FILL VOID WITH APPROVED NON-COMBUSTIBLE MATERIAL (ROCK WOOL INSULATION). AT RATED PARTITIONS, SEAL BOTH ENDS OF OPENING WITH APPROVED FIRE -CAULK PIPING PIPING AT INTERIOR NOT TO SCALE NOTE: ELEVATE A/C UNIT SUFFICIENT DISTANCE ABOVE FINISHED FLOOR OR ROOF TO ALLOW FOR INSTALLATION OF TRAP WITH ADEQUATE DIMENSIONS TO WITHSTAND SYSTEM OPERATING PRESSURE. COORDINATE WITH DETAIL FOR A/C UNIT MOUNTING. VENT TEE CLEAN OUT PLUG UNION WALL H x TEE ELBOW BOTTOM ROUTE PIPE TO NEAREST FLOOR DRAIN AS SHOWN ON PLANS SEE SPECIFICATIONS FOR PIPING MATERIAL DRAIN PAN CONNECTION FULL CONNECTION PIPE SIZE MIN. 1-1/4" FLOOR TOTAL HEIGHT OF TRAP= X+H+ ( 1 1/2 FOR DRAW THRU UNITS X= MIN. 1/2 H (PREFERRED X=H) H= NEGATIVE STATIC PRESSURE +1' x PIPE DIAMETER ) FOR BLOW THRU UNITS X= FAN STATIC PRESSURE +1" H= MIN. 1" CONDENSATE DRAIN PIPING NOT TO SCALE CLAMP UNISTRUT SHOULDER BOLT BOLT UNISTRUT TO FLOOR. SHIM UNDERSIDE AS REQUIRED TO KEEP LEVEL REFRIGERANT PIPE PIPE INSULATION CUSHION I NOTES: 1) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. 2) SPACING OF SUPPORTS PER SPECIFICATIONS. SUPPORT SPACING SHALL BE BASED ON THE SMALLEST DIAMETER PIPE SUPPORTED BY THE RACK. REFRIGERANT PIPE SUPPORT NOT TO SCALE SUPPLY AIR DUCT SPIN —IN TAP WITH VOLUME DAMPER. 11111 II IIILIIIIII STAINLESS STEEL DRAWBAND WITH WORM GEAR TIGHTENING SCREW. CLAMP INNER LINER TO GRILLE COLLAR. SEAL OUTER VAPOR BARRIER TO. BACK OF GRILLE/DUCT. ,I 1 SEE SPECIFICATIONS FOR TYPE OF TAPE, FLEX DUCT. INSULATED FLEX DUCT. MAX. 8 FT. LENGTH CEILING SCHEDULED AIR DEVICE NOTE: SUPPORT FLEX DUCT FROM STRUCTURE SO THAT IT DOES NOT KINK, SAG OR REST ON LIGHT FIXTURES, CEILING SUPPORT TEES OR TILE. SA GRILLE.. CONNECTION NOT TO SCALE TYPICAL MANUAL VOLUME DAMPER 1 W 1 MAIN SUPPLY RETURN OR EXHAUST DUCT 45' n III L LJ TYP. RECTANGULAR TAKE -OFF. USE SMACNA 45' ENTRY FITTING L = 1/4W (4" MIN. ti 2 SPIN —IN FITTING WITH MAN UAL VOLUME DAMPER DUCT BRANCH TAKE NOT TO SCALE THREADED ROD UNISTRUT CUT HANGER ROD FLUSH WITH BOTTOM NUT. IYP. ROUND TAKE -OFF OFF PREFORMED THERMOPLASTIC PIPE SADDLE WITH GALVANIZED CLAMP SIZED TO MATCH PIPE SIZE. CUSH-A-CLAMP, VIBRACLAMP, OR EQUAL. NOTES: 1) THIS DETAIL APPLIES TO INSULATED AND UNINSULATED COPPER PIPING. REFER TO SPECIFICATIONS FOR INSULATION REQUIREMENTS. 2) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. 3) MAXIMUM ALLOWABLE SPACING OF HANGERS (HANGER SPACING SHALL BE BASED ON THE SMALLEST DIAMETER PIPE SUPPORTED BY THE RACK): COPPER PIPE: ) " TO 1Y" - 5'-0" O.C. 2" TO 2Y" - 8'-0" O.C. 4) PROVIDE HANGER AT ALL CHANGES OF DIRECTION. MULTIPLE PIPE HANGER NOT TO SCALE RATED WALL OR PARTITION DAMPER BLADE ASSEMBLY WITH UL LISTED FUSIBLE LINK AIR FLOW SIDEWALL SUPPLY AIR GRILLE OPENING IN STUD WALL FOR DUCT PENETRATION SHALL HAVE A STUD FRAME ON ALL SIDES. RETAINING ANGLE SHALL BEAR ON STUD FRAME. CONNECT SLEEVE TO DUCT WITH SLIP JOINT DUCT TRANSITION DUCT ACCESS DOOR IN DUCT. REFER TO SPECIFICATIONS FOR DOOR TYPE AND SIZE. 1-1/2"x1-1/2"x1/8" RETAINING ANGLE. SEE NOTE. NOTES: 1. PROVIDE UL LISTED DAMPER AND SLEEVE IN ACCORDANCE WITH UL 555. 2. INSTALL DAMPER AND SLEEVE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS NOT TO VOID UL LISTING. 3. EXTEND SLEEVE BEYOND WALL MAX. 6 INCHES. 4. PROVIDE EXPANSION SPACE PER MANUFACTURER'S INSTRUCTION, BUT NOT LESS THAN 1/8" PER LINEAL FOOT IN BOTH DIRECTIONS. 5. PROVIDE MINIMUM 1-1/2" x 1-1/2" x 1/8" RETAINING ANGLE ON TOP, BOTTOM AND SIDES. ATTACH ANGLES TO SLEEVE IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ANGLES SHALL OVERLAP WALL A MINIMUM OF 1". DUCT FIRE DAMPER NOT TO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED APR 16 2014 City of Tukwila BUILDING DIVISION tH Ooq'l SPLIT RING TYPE HANGER HANGER ROD AS REQUIRED SPACING OF HANGERS PER SPECIFICATIONS TURNBUCKLE AS REQ' 18 GA. GALV. SHEETMETAL SADDLE MINIMUM 8" LONG PROVIDE FULL CIRCUMFERENCE 12" LONG SECTION OF HIGH COMPRESSION STRENGTH CLOSED -CELL INSULATION AT EACH HANGER POINT NOTES: 1) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. 2) MAXIMUM ALLOWABLE SPACING OF HANGERS: STEEL PIPE: Y2" TO 1Y" - 7'-0" O.C. 2" TO 23/2" - 10'-0" O.C. COPPER PIPE: Y" TO 1Y" - 5'-O" O.C. 2" TO 2Y" - 8'-0" O.C. CAST IRON PIPE: ALL - 10'-0" O.C. 3) PROVIDE HANGER AT ALL CHANGES OF DIRECTION. CLEVIS TYPE HANGER SINGLE PIPE HANGER NOT TO SCALE REC EIVED CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 D: EDCSEA01 W co crj a N ISSUES & REVISIONS Na Date Description 1 02/17/2014 ISSUE FOR PERMIT 03/28/2014 ADDENDUM 1 SHEETTITLE MECHANICAL DETAILS DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEET NO. M7.1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. TWO —TIERED UNISTRUT PIPING SUPPORT OFCI ECONO—PHASE REFRIGERANT PUMP MODULE. INSULATE ALL REFRIGERANT PIPING AND FITTINGS INSIDE ERP MODULE. (2)56"Wx36"H RETURN AIR OPENINGS FOR EACH CRAC UNIT. 1-1/2" ANGLE IRON FRAME AND 3/4" EXPANDED METAL WELDED TO INSIDE. OFCI LEAK DETECTION CABLE. SECURE TO FLOOR. FRONT ELEVATION FIELD WELD UNIT TO FLOOR STAND, IF REQUIRED. REFER TO STRUCT. (2)24"Hx56"W SUPPLY AIR OPENINGS BELOW RAISED FLOOR. 2x2x1/8 GALV ANGLE IRON; SECURE TO FLOOR AND CAULKi.I OFCI SEISMIC ANCHORING, IF REQUIRED. REFER TO STRUCT. 2 \ / AV/ NVAVAVA Rom; ` TWO —TIERED UNISTRUT PIPING SUPPORT REFRIGERANT PIPING m 0 a a m m m m m m a m x36"H RETURN AIR ;S WITH EXPANDED METAL Y GRATES FOR EACH UNIT. — '—IN CEILING 11-1/8" HOT GAS, (2)7/8" !UID, AND 3/4" PCD DATA CENTER ------------------ REFRIGERANT PIPING =1 � m_ 0 0 0 0 m m HUM PIPING PCD PIPING LIGHT FIXTURE OFCI FILTER ASSEMBLY. FILTERS REMOVED THROUGH IFRONT OF PLENUM. MECHANICAL CORRIDOR 1Hx56"W SUPPLY AIR VGS BELOW RAISED FLOOR. AISED FLOOR CRAG EC FANS TO REMAIN IN THEIR ��SHIPPED POSITION INSIDE UNIT. PROGRAM FANS TO ROTATE UPON SHUTDOWN TO PREVENT BACKDRAFT. INSULATED SHEET METAL PLENUM WRAPPED AROUND FLOOR STAND. Amir mr_ �� CONT TO LOWER OFCI EC 4H— . OFCI LEAK DETECTION OFCI LEAK DETECTION MODULE CABLE BELOW UNIT AS DIRECTED NUFACTURER. ESA -- — llr/�:7/�ir FI (SHED FLOOR SHEET METAL BLANK OFF PANEL SECURED TO FRAME FOR ALL SIDE ELEVATION FUTURE CRACS. DOWNFLOW CRAC UNIT WITH ECONO-PHASE REFRIGERANT PUMP NOT TO SCALE 2x2x1/8 GALV ANGLE IRON; SECURE TO FLOOR AND CAULK. PRE —FABRICATED SEISMIC FLOOR STAND, IF REQUIRED. REFER TO CRAC SCHEDULE ON SHEET M0.1. ROOF UNISTRUT MOUNTED TO WALL 7/8" HOT GAS LINE 5/8" LIQUID LINE SUPPLY AIR GRILLE OFCI LEAK DETECTION CABLE. SCREWED TO FLOOR. —\\, FINISHED FLOOR "-3/4" PUMPED CONDENSATE LINE CRAC I NEOPRENE VIBRATION ISOLATION PADS UPFLOW CRAC UNIT NOT TO SCALE LEAK DETECTION MODULE 2x2x1/8 GALV ANGLE IRON; SECURE TO FLOOR AND CAULK. ROOF 7/8" HOT GAS, 5/8" LIQUID, AND 3/4" PCD PRE —ACTION RM CRAC FULL SIZE SUPPLY AIR HEADER BY MECH CONT Ste-- -"—SUPPLY AIR GRILLE RA UPS ELECT. RM FINISHED FLOOR SEISMIC ANCHORING. REFER TO STRUCT. ROOF 0 PROVIDE REFRIGERANT SHUT OFF VALVES. 0 5 a AIR—COOLED CONDENSER (OUTDOORS) 0 0 a+ ox AIR—COOLED CONDENSER (OUTDOORS) A OFCI LIEBERT DSE RECEIVER PIPING SUPPORTS (TYP.) ,-- HOT GAS LINE (2)\ PROVIDE REFRIGERANT SHUT OFF VALVES —' COOLING COIL ECONOMIZER REFRIGERANT PUMP A V V a --J rJ I LIQUID LINE (2) TT 1 F 7X x x77VA X X X X X �K�xxxxxxxxxxxxx �( L CRAC UNIT (INDOOR) 1 .cmxc=. c=, \cd\ /cn/ \ cm\ I \cm\ I L/c=/ \cm\ c=. . I 'i./' I I jv --1--� COMP. COMP. (2) (2) Ho , Ho /. i ROOF PIPING PENETRATION. CURB AND HOOD PROVIDED BY MECH CONT AND INSTALLED BY GEN CONT. TWO(2) SETS OF REFRIG PIPING CIRCUITS. REFER TO MANUFACTURER AND DRAWINGS FOR QUANTITIES, SIZES, APPURTENANCES, AND ROUTING DETAILS. CONTROL WIRING IN CONDUIT BY ELECT CONT. REFER TO ELECT DWGS. RETURN AIR FILTERS r�,,,,,,—CONTROL PANEL Lr SMOKE DETECTOR TIED INTO EXISTING BUILDING FIRE ALARM CONDENSATE DRAIN PAN CONDENSATE PUMP — MOUNT CRAC UNIT ON SUPPORT STAND. STAND FURNISHED WITH UNIT RUN HOT GAS PIPING LEVEL OR SLOPE AWAY FROM THE COMPRESSOR (IN DIRECTION OF FLOW). REVIEWED FOR CODE COMPLIANCE APPROVED APR 16 2014 City of Tukwila BUILDING DIVISION RAISED FLOOR FLOOR SLAB CONDENSATE PIPING ROUTE TO EXISTING LINE AND TIE IN MOUNT MOISTURE DETECTION MODULE. —DETECTOR FURNISHED WITH UNIT. Factory provided internal controls shall control the CRAC and ACC functions to maintain space humidity and temperature set —points and cycle econo-phase refrigerant pumping sequence. 1) The internal fan operates continuously. The compressor unloads and cycles on/off as needed to maintain the set —point. The condensing unit fans speed up/down and cycle on/off as controlled by the CRAC control panel. 2) The unit mounted smoke detector shall, upon sensing smoke, shut down the unit and notify the building fire alarm system. The CRAC will restart after the smoke detector has been manually reset. 3) The leak detection system shall, upon sensing moisture, alarm at the unit control panel but will not shut the unit off. DX SYSTEMS - CRAC SEQUENCE OF OPERATION AND REFRIGERANT PIPING DETAIL NOT TO SCALE RECEIVED CITY OF TUKWILA APR 1 1 2014 PERMIT CENTER Gens Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 er x CD c CD CD LLJ Cn 0 0 LLJ 0 Ul 0) 1 / ISSUES & REVISIONS Na 1 Date Description 02/17/2014 ISSUE FOR PERMIT 03/28/2014 ADDENDUM 1 C J SHEET WILE MECHANICAL DETAILS DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEET NO. M7.2 J PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. MECHANICAL SYMBOLS E, MANUAL VOLUME DAMPER :> M MOTORIZED VOLUME DAMPER BDD BDD BACKDRAFT DAMPER FD OM miClim Meal FD FIRE DAMPER SD MIN SD SMOKE DAMPER FSD OWN 111:' EMU FSD COMBINATION FIRE/SMOKE DAMPER ---SD Nv SMOKE DETECTOR ce TM RISE IN DUCT ELEVATION o © DROP IN DUCT ELEVATION RADIUS ELBOW / j MITERED ELBOW WITH TURNING VANES j } CONNECTION TO MAIN IBRANCH j - - TRANSITION DUCT WITH INTERNAL LINER j-8� - �x\ SUPPLY DUCT UP, DOWN I\ ' j RETURN/EXHAUST DUCT UP, DOWN \ SUPPLY GRILLE WITH AIR QUANTITY 1 100 RETURN/EXHAUST GRILLE WITH AIR QUANTITY /100R/1OOE TQ THERMOSTAT 0 HUMIDISTAT %H TEMPERATURE/HUMIDITY SENSOR TEMPERATURE SENSOR T AIR-COOLED CONDENSING. UNIT SCHEDULE (OFCI) UNIT TAG CON0101'I CON02012 CON0:3021 CON04.022 CON05031 CON06032 CON13171 .CON14:181 CON 17010 CON18091 MANUFACTURER LIEBERT LIEBERT LIE:BERT LIEBERT LIEBERT LIEBERT LIEBERT MODEL NUMBER M:CL165.E1A MCL1 65E1A IVICL165ElA MOM 10E8A MCLII•OE8A PFH037A-AH7 PFHO37A-AH7 AREA SERVED DATA CENTER DATA CENTER DATA=CENTER. UPS ROOM UPS ROOM ISS MMR2 CRAC UNIT SERVED CRA01000 CRA02000 CRA03000 CRA07000 CRA08000 CRA09000 CRA10000 AM BIENT TE MP. ('F) 105 105 105 105 105 1055 105 REFRIGERANTTYPE R-41.0A R 10A R-410A R-407C R-407C. R-407C R-407C FAN QUANTITY (EACH) 3 3 :3 2 2 1 1 FLA (EACH) 8.4 8,4 8 4 8.4 - 8:4 8.1 8..1 VOLTS/PHASE/HERTZ 460/3/60 460/3/60 46.0/3/60 460/3/60 460/3160 460/3/60 460/3/60 REMARKS 1,2,3,4 1,2,3,4 1,2,3,4 2,4 2,4 2 2 REMARKS: 1. 18" SUPPORT LEGS.. 2, FACTORY WIRED DISCONNECT SWITCH: 3, ONE(1) REFRIGERANT RECEIVER AND BRACKET ASS EMBLY FOR EACH 3-FAN CONDENSNGUNIT SECTION. 4. A.LARIUI TERMINAL CONNECTIONS. ECONO- UNIT TAG ERP01000 E RP02000 E RP03000 MANUFACTURER LIE.BE.RT LIEBE RT LIEBERT MODEL NUMBER P R125AA6DD-0000 PR:125AA6DD-0000 P R125AA6DD-0000 CRAC UNIT SERVED CRA01000 CRAO2000 CRA03000 PUMP TYPE RE FRIG'E RANT 'REFRIGERANT REFRIGERANT QUANTITY OF PUMPS 2 2 2 HORSEPOWER 1.6 1.6. 1.6 VOLTS/PHAS EIH E RTU. 480/3/60 480/3/60 480/3/60 FULL LOAD AMPS (FLA) 3.5 (EACH) 3.5. (EACH) 3.5 (EACH) REMARKS. NOTES: 1, DUAL PUMP CONFIGURATION WITH:(1+1;) REDUNDANCY.' 2. 65,000.AMP SOCK. 3.. REFRIGERANT PUMP MODULE CONTROLLED BY ASSOCIATED ORAC ICOM CONTROL 1,2,3: 1,23 UPS ROOM VENTILATION CALCS CODE REFERENCE: 2006 IFC CHAPTER 6 SECTION 608.5 - STATIONARY LEAD -ACID BATTERY SYSTEM VENTILATION. SECTION 608.5 - LIMIT HYDROGEN TO LESS THAN 1 % CONCENTRATION OF SPACE VOLUME. UPS ROOM : VOLUME: 1,270. SQ.FT. x 20' HIGH = 25,400 CU.FT. VOLUME. UPS ROOM IS DESIGNED TO CONTAIN 320 BATTERIES. HYDROGEN .GASSING FROM MANUFACTURER'S DATA: - EACH BATTERY CELL HAS A HYDROGEN GASSING RATE OF 0.00134 CF/HR/CELL DURING FULL CHARGING (WORST CASE). - TOTAL GASSING RATE IS (320 CELLS) x (0.00134 CF/HR/CELL) = 0.423 CF/HR. - HYDROGEN GASSING AIR CHANGE IS (0.423 CF/HR) x (1 AC/25,400 CF) = 0.0000167 HYDROGEN AC/HR - MAX. ALLOWABLE 1% HYDROGEN CONCENTRATION OF ROOM VOLUME IS (25,400 CF) x (0.01) = 254 CF. - TIME TO PRODUCE 254 CF OF HYDROGEN IS (254 CF) / 0.423 CF/HR = 600.5 HRS = 25.0 DAYS. UPS RM EXHAUST SYSTEM: - UPS ROOM A EXHAUST SYSTEM EXHAUSTS (200 CF/M) x (60 M/HR) = 12,000 CF/HR » 0.423 CF/HR. - EXHAUST SYSTEM AIR CHANGE(AC) RATE IS (12,000 CF/HR) x (1 AC/25,400 CF) = 0.47 AC/HR » 0.0000167 HYDROGEN AC/HR. 1,2,3 FAN SCHEDULE MARK EXF01000 EXF02000 SERVES UPS/ELECT RM TOILET RMS TYPE/DRIVE CENT/D:IRECT CENT/DIRECT C.FM 200 200 EXT. S.P..(IN. W.G) 0.30 0.30 HORSEPOWER (WATTS) -(170) (170) RPM (MAX) 1,145 1,145 SONES (MAX). 2.9 29 VOLTS/PHASE/HERTZ. 12011/600 1.20/1/60 MAN:UFACTIJRER COOK COOK MODEL NUMBER_ GC-420 'GC-420 NOTES 1;2 1,3 NOTES: 1: PROVIDE BACKDRAFT DAMPER, 8" ROUND DUCT WALL CAP, AND FAN SPEED CONTROL. 2. FAN SHALL RUN CONTINUOUSLY. 3. FAN CONTROLLED THRU RESTROOM LIGHT SWITCFL REFER TO. ELECT. MECHANICAL SYMBOLS PCD-j PUMPED CONDENSATE DRAIN - REFRIGERANT HOT GAS -----RHG--? REFRIGERANT LIQUID j-RL -- PIPE UP o1 j C) I d PIPE DOWN oj ( 1 I d CAP [ j i d I 90° ELBOW j 1 A RISE OR DROP IN ELEVATION t C-c-►--j h I( IC )i d TEE OR BRANCH CONNECTION CONNECT TO EXISTING ABBREVIATIONS E - EXISTING TO REMAIN PC PUMPEDCONDENSATE D - 0 DENSATE DRAIN R - RELOCATE OA - OUTSIDE AIR D - DEMOLISH EA - EXHAUST AIR AFF - ABOVE FINISHED FLOOR RA - RETURN AIR OBD - OPPOSED BLADE DAMPER SA - SUPPLY AIR BDD - BACKDRAFT DAMPER SWR - SIDEWALL REGISTER CRAC - COMP. RM. A/C UNIT UNO - UNLESS NOTED OTHERWISE RHG - REFRIGERANT HOT GAS CFM - CUBIC FEET PER MINUTE RL - REFRIGERANT LIQUID OFCI - OWNER FURNISHED, CONTRACTOR INSTALLED. OWNER FURNISHED ITEMS ARE PURCHASED AND WARRANTED AS STATED IN THESE DOCUMENTS BY BURR COMPUTER ENVIRONMENTS, INC. MECHANICAL GENERAL NOTES 1. REFER TO THE SPECIFICATIONS FOR ALL MATERIALS, MANUFACTURERS, METHODS OF CONSTRUCTION AND INSTALLATION PROCEDURES UNLESS NOTED OTHERWISE IN THIS SET OF PLANS. 2. THE CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE AND BECOMING FAMILIAR WITH THE EXISTING BUILDING AND CONDITIONS WITHIN THE SCOPE OF THIS PROJECT. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING WITH OTHER TRADES PRIOR TO FABRICATING AND INSTALLING THE MECHANICAL SYSTEMS. 3. THE APPROXIMATE LOCATIONS OF MECHANICAL ITEMS ARE SHOWN ON THE PLANS. THESE PLANS ARE NOT INTENDED TO GIVE COMPLETE AND ACCURATE DETAILS IN REGARD TO LOCATION OF DEVICES, EQUIPMENT, ETC.. EXACT LOCATIONS SHALL BE DETERMINED BY ACTUAL MEASUREMENTS TAKEN AT THE BUILDING AND IN COORDINATION WITH EXISTING CONDITIONS AND ALL OTHER TRADES. 4. ALL WORK SHALL COMPLY WITH PERTINENT STATE AND LOCAL CODES. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL NECESSARY PERMITS, FEES, AND INSPECTIONS. 5. WORK SHALL BE EXECUTED IN A WORKMANLIKE MANNER AND SHALL INCLUDE ALL LABOR AND MATERIALS ESSENTIAL TO PROVIDE COMPLETE FUNCTIONING SYSTEMS AS DESCRIBED IN THE CONTRACT DOCUMENTS. IN CASES OF DOUBT AS TO THE WORK INTENDED, OR IN THE EVENT OF NEED FOR EXPLANATION, THE CONTRACTOR SHALL REQUEST ADDITIONAL INFORMATION FROM THE ARCHITECT/ENGINEER. WORK SHALL NOT PROCEED WITHOUT CONFIRMATION BY THE ARCHITECT/ENGINEER. 6. THE CONTRACTOR IS REQUIRED TO PROVIDE SUBMITTALS FOR ALL MATERIALS AND EQUIPMENT TO BE INSTALLED WITHIN THE SCOPE OF THIS PROJECT. 7. THE CONTRACTOR SHALL WARRANT THE INSTALLATION OF THE EQUIPMENT PURCHASED BY THE OWNER FOR ONE YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION AS DETERMINED BY THE OWNER. 8. THE CONTRACTOR SHALL WARRANT THE EQUIPMENT AND INSTALLATION OF THE EQUIPMENT PURCHASED BY THE CONTRACTOR FOR ONE YEAR AFTER THE DATE OF SUBSTANTIAL COMPLETION AS DETERMINED BY THE OWNER. 9. DUCT DIMENSIONS SHOWN ON THE DRAWINGS ARE CLEAR INSIDE DIMENSIONS. 10. GRILLES, REGISTERS, AND DIFFUSERS SHALL BE AS PER THE SCHEDULE. FRAME TYPE OF EACH DEVICE SHALL BE DESIGNED FOR THE CEILING TYPE IN WHICH IT IS INSTALLED. 11. COORDINATE THE LOCATION OF ALL AIR DISTRIBUTION DEVICES WITH THE ARCHITECTURAL REFLECTED CEILING PLAN, INCLUDING LIGHT FIXTURES, SPRINKLER HEADS, SPEAKERS, AND SMOKE DETECTORS. 12. MECHANICAL EQUIPMENT AND DEVICES (VALVES, DAMPERS, TERMINAL UNITS, ETC.) INSTALLED ABOVE INACCESSIBLE CEILINGS SHALL HAVE ACCESS DOORS INSTALLED IN THE CEILING TO ALLOW FOR SERVICE. THE MECHANICAL CONTRACTOR SHALL FURNISH THESE ACCESS DOORS FOR THE GENERAL CONTRACTOR TO INSTALL THE MECHANICAL CONTRACTOR SHALL COORDINATE THE LOCATION OF THESE DOORS WITH THE ARCHITECT TO BEST ALLOW FOR SERVICE AND ARCHITECTURAL APPEARANCE. 13. THE CONTRACTOR SHALL PROVIDE TEMPORARY FILTER MEDIA AS REQUIRED FOR THE OPERATION OF CRAC'S, RTU'S DURING CONSTRUCTION. THESE FILTERS ARE TO BE CHANGED AS NEEDED THROUGHOUT THE CONSTRUCTION PROCESS. THE UNITS SHALL NOT RUN WITHOUT THESE FILTERS INSTALLED. THE CONTRACTOR SHALL INSTALL THE FILTERS PROVIDED WITH THE UNIT PRIOR TO THE AIR BALANCE OF EACH UNIT. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 14. VERIFY LOCATION OF THERMOSTATS AND SPACE TEMPERATURE SENSORS WITH THE ARCHITECT/ENGINEER PRIOR TO INSTALLATION. INSTALL THERMOSTATS AND SENSORS AT THE SAME CENTERLINE ELEVATION AS LIGHT SWITCHES. 15. ALL MATERIALS EXPOSED WITHIN DUCTS OR PLENUMS SHALL HAVE. A FLAME -SPREAD INDEX OF NOT 'MORE THAN 25 AND A SMOKE -DEVELOPED RATING OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE WITH THE TEST FOR SURFACE BURNING CHARACTERISTICS OF BUILDING MATERIALS, ASTM E-84-91A AND ANSI/UL 723-86. 16. MECHANICAL CONTRACTOR TO PROVIDE AIRSIDE TEST AND BALANCE (NEBB OR AABC) FOR ALL AFFECTED HVAC SYSTEMS, INCLUDING ALL AIR DEVICES, AIR TERMINAL UNITS AND ROOFTOP AIR CONDITIONING UNITS WITHIN THE SCOPE OF WORK. REFER TO SHEET M2.1 FOR AIR QUANTITIES. CRAC UNIT SCHEDULE (OFCI) UNIT TAG CRA01000 CRA02000 CRA03000 CRA07000 CRA08000 CRA09000 CRA10000 LIEBERT MODEL NUMBER DA150DP1A VSO42ADA000 MMD36E7AOODO MMD36E7AOODO AREA SERVED DATA CENTER UPS RIVI ISS MMR2 TYPE AIR-COOLED AIR-COOLED AIR-COOLED AIR-COOLED UNIT CONFIGURATION DOWNFLOW UPFLOW DOWNFLOW DOWNFLOW SUPPLY FAN SUPPLY AIR (CFM) 18,000 6,300 1,250 1,250 MOTOR QUANTITY 3 EC 1 1 1 EXT. SP (IN. W.G.) 0.2 0.2 0.3 0.3 HP (EACH) 3.7 7.5 0.5 0.5 z J 8 U EAT DB/WB (°F) 75/61 75/61 75/61 75/61 LAT DB/WB CF)55/54 55/54 55/54 55/54 SENSIBLE COOLING CAPACITY - KW (MBH) 134 (457) 36.4 (124.2) 8.3 . (28 4) 8 3 (28.A) TOTAL COOLING CAPACITY - KW (MBH) 134 (457) 42 (143.3) 9.55 (32.5) . 9.55 (32,5) FACE VELOCITY (FPM) 320 368 .. 394 '394.. HUMIDIFIER TYPE INFRARED NA NA. NA CAPACITY (LBSIHR) 22.0 NA NA NA ELECTRIC REHEAT kW 30.0 NA NA NA STEPS 3 NA NA NA ELECTRICAL FLA (FLA. W/ HUM & REHEAT LOCKED OUT) 102.7 (91.1) 39.2 (NA) 1.4 (NA) 1.4 (NA) V/PH/HZ 460/3/60 460/3/60 460/3/60 460/3/60 REMARKS 1,2,3,4,5,6,7,8 9,10,1 2,13,14,15,16 3,4 5,6,9,10,11,12 14, 15,16,17 3,5,10,12,17,18,19 3,5,10,12,17,18,19 REMARKS: 1. ELECTRICALLY COMMUTATED FAN MOTORS. 2. R-410A REFRIGERANT. 3. 4" FILTERS, ME.RV-8,RATING. 4. LT460-Z25 LEAK SENSOR WITH 25 FT LEAK DETECTION CABLE. FIELD INSTALLED. 5. FACTORY. INSTALLED DUAL FLOAT CONDENSATE PUMP. 6. ADVANCED MICROPROCESSOR -BASED TEMPERATURE AND HUMIDITY CONTROLS. 7. ACCOMPANIED BY RESPECTIVE MICRO -CHANNEL AIR-COOLED CONDENSER AND ECONOPHASE REFRIGERANT PUMP PACKAGE. REFER TO ACLU SCHEDULE. 8. 30" HIGH FLOOR STAND. 9. 65,000 AMPS SHORT CIRCUIT CURRENT RATING. 10. NON -LOCKING DISCONNECT SWITCH. 11. ACCOMPANIED BY RESPECTIVE MICRO -CHANNEL AIR-COOLED CONDENSER. REFER TO ACCU SCHEDULE. 12. LOW VOLTAGE TERMINAL PACKAGE. 13. REHEAT AND HUMIDIFIER LOCKOUT. 14. UNITY COMMUNICATION NETWORKING CARD.. 15. SMOKE SENSOR WI11-I UNIT ALARM AND SHUTDOWN, INCLUDING SUPERVISION CONTACTS. 16. iCOM CONTROL WITH LARGE DISPLAY. 17. R-407C REFRIGERANT. 18. AIR DISTRIBUTION PLENUM 19. WALL MOUNTED UNIT CONTROLLER SEPARATE PERMIT REQUIRED FOR; ❑ Mechanical i3'Ptu mbing t G`as Piping at,,, j, of Tukwila BI P! ` ,,X:; DIVISION REVISIONS r i+^ 7p ma's shall be mace to tom* -rope c.f 1"ork without prior approvs Building Division_ will require a new rz. mittat r j , :ude additional plan ret7' MECH MATERIAL SPECIFICATIONS 1. REFRIGERANT PIPING UP THROUGH 2": DRAWN TEMPER COPPER TUBING ASTM B 88 TYPE "L" WITH WROUGHT COPPER FITTINGS (ASTM B16.22). SILVER SOLDER ALL JOINTS WITH AWS A5.8 CLASSIFICATION B AG-1 SILVER SOLDER. UTILIZE NITROGEN PURGE WHILE BRAZING. 2. REFRIGERANT VALVES: A) SHUT OFF VALVE UP THROUGH 2": 1) STRAIGHT THROUGH BALL VALVES: VALVE RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. FULL PORT, FORGED BRASS OR BRONZE BODY AND BONNET COVER, CHROME PLATED BRONZE BALL PTFE, OR TFE SEATS, AND WITH SOLDER END CONNECTIONS. 2) PACED -ANGLE VALVES: RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. FORGED BRASS OR BRONZE BODY, FORGED BRASS SEAL CAPS WITH COPPER GASKET, .BACK SEATING, RISING STEM AND SEAT, MOLDED STEM PACKING, AND WITH SOLDER END CONNECTIONS. B) SERVICE VALVES: RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. FORGED BRASS BODY WITH COPPER STUBS, BRASS CAPS, REMOVABLE VALVE CORE AND WITH SOLDER END CONNECTIONS. 3. REFRIGERANT SPECIALTIES: A) MOISTURE/LIQUID INDICATORS: RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE. ALL BRASS BODY WITH REPLACEABLE, POLISHED, OPTICAL VIEWING WINDOW WITH COLOR CODED MOISTURE INDICATOR AND WITH SOLDER END CONNECTIONS. B) STRAIGHT THROUGH OR ANGLE TYPE STRAINERS: RATED FOR 500 PSIG WORKING PRESSURE AND 275'F WORKING TEMPERATURE FORGED BRASS OR STEEL BODY WITH STAINLESS STEEL WIRE OR BRASS REINFORCED MONEL SCREEN. 80 TO 100 MESH IN LIQUID LINES UP TO 1)6" IN SIZE, 60 MESH FOR LARGER LIQUID LINES, AND 40 MESH IN SUCTION LINES. PROVIDE SCREWED CLEAN OUT PLUG AND SOLDER END CONNECTIONS. C) PERMANENT FILTER DRIERS: RATED FOR 350 PSIG WORKING PRESSURE AND 225'F WORKING TEMPERATURE. STEEL SHELL AND WROUGHT COPPER FITTINGS FOR SOLDER END CONNECTIONS. MOLDED FELT CORE SURROUNDED BY DESSICANT. 4. PIPING INSULATION: A) REFRIGERANT PIPING (HOT GAS AND LIQUID FOR DATA CENTER DSE SYSTEMS): 1/2" THICK CLOSED -CELL FLEXIBLE ELASTOMERIC. ALUMINUM JACKET WITH PRE -MOLDED FITTINGS (OUTDOOR ONLY). B) REFRIGERANT PIPING (HUT GAS FOR UPS RM DS SYSTEMS): 1/2" THICK CLOSED -CELL FLEXIBLE ELASTOMERIC. ALUMINUM JACKET WITH PRE -MOLDED FITTINGS (OUTDOOR ONLY). C) CONDENSATE DRAIN: ) " THICK FIBERGLASS WITH ASJ. SEAL VAPOR BARRIER. PROVIDE PRE -MOLDED FITTINGS.; 5. ALL DUCTWORK SHALL BE CONSTRUCTED OF NEW LOCK FORMING QUALITY GALVANIZED SHEET METAL IN ACCORDANCE WITH THE LATEST SMACNA STANDARDS TO THE 2" W.G. PRESSURE CLASSIFICATION. ALL LONGITUDINAL SEAMS AND TR SVERSE JOINTS SHALL BE SEALED PER SMACNA DUCT SEALING REQUIREMENTS SEAL CLASS "B". SEAL WITH A WATER BASED ADHESIVE SEALER DESIGNED FOR MEDIUM VELOCITY DUCT SYSTEMS. SEALER SHALL BE HARDCAST, INC., "IRON GRIP WATER BASE DUCT SEALANT #601." DUCTWORK SHALL BE HUNG AS HIGH AS POSSIBLE FROM THE BUILDING STRUCTURE WITH HANGER ASSEMBLIES IN. ACCORDANCE WITH "SMACNA" REQUIREMENTS. THE CONTRACTOR SHALL PROVIDE ADDITIONAL RISES, DROPS, AND OFFSETS IN DUCTWORK AS REQUIRED. 6. ALL INSULATION SHALL HAVE A COMPOSITE ' (INSULATION, JACKET OR FACING, AND ADHESIVE USED TO ADHERE FACING OR JACKET TO INSULATION) FIRE AMD SMOKE HAZARD RATING (AS TESTED BY PROCEDURE ASTM E84, NFPA 225, AND UL 273) NOT EXCEEDING A FLAME SPREAD RATING OF 25 AND A SMOKE DEVELOPED RATING OF 50. 7. ALL EXPOSED SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL NOT BE INSULATED. ALL CONCEALED SUPPLY, RETURN, AND EXHAUST AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH 1 1/2" THICK DUCT WRAP, 3/4 LB/CU.FT. INSULATION. INSULATION SHALL HAVE A FACTORY APPLIED FOIL-SKRIM-KRAFT FACING CONSISTING OF 0.35 MIL ALUMINUM FOIL REINFORCED WITH GLASS YARN MESH AND LAMINATED TO 40 POUND CHEMICAL TREATED, FIRE RESISTANT KRAFT. OVERLAP ALL SEAMS, STAGGER LONGITUDINAL SEAMS. SEAL SEAMS WITH 4" WIDE PRESSURE SENSITIVE TAPE AND OUTWARD CLINCHING STAPLES. USE SPEED CLIP PINS ADHERED TO DUCT SURFACES OVER 18" IN WIDTH ON 16" CENTERS AND MAX. 3" FROM INSULATION SEAMS. APPLY BRUSH ON VAPOR RETARDANT MASTIC OVER TAPE EDGES, PINS, AND TEARS IN THE FOIL VAPOR BARRIER. MINIMUM INSULATION MUST MEET IEC (R-3.3). AIR DEVICE SCEDULE MARK MFR. & MODEL TYPE REMARKS 10 TITUS TMSA AA LOUVERED SUPPLY AIR GRILLE ALUMINUM CONSTRUCTION, LAY! IN FRAME, FULL FACE, WHITE `FINISH, REFER TO INLET SIZING CHART FOR NECK SIZE. _/ TI11JS PAR PERFORATED RETURN AIR GRILLE ALUMINUM CONSTRUCTION, TYPE-3 LAY -IN FRAME, WHITE FINISH 22x22 NECK• ' 0 TITUS 301 FL S.IDEVVALL SUPPLY AIR GRILLE . ALUMINUM CONSTRUCTION, 3/4" BLADE SPACING, ALUMINUM FINISH, DOUBLE DEFLECTION WITH FRONT BLADES PARALLEL TO LONG DIMENSION_ 3500 FL F SIDEWALL EXHAUST AIR: GRILLE . ALUMINUM CONSTRUCTION, 3/4" BLADE SPACING, ALUM:INUM-FINISH„ DOUBLE DEFLECTION WITH FRONT BLADES PARALLEL TO LONG DIMENSION. ts: 1. STANDARD WHITE FINISH. 2. PROVIDE SQUARE TO ROUND NECK TRANSITION FOR CONNECTION TO FLEX DUCT. FILE COPY Permit No.tAl14-0CAll Plszi review approval is subject to errors and omissions. E of construction documents does not authorize DCI of any adopted code or ordinance. Receipt riF approved Field Copy and conditions is acknowledged By Date;/7 i City Of Tukwila BUILDING DIVISION FAN COIL UNIT - CONDENSING UNIT SCHEDULE FURNACE MARK MFG. MODEL # O M BLOWER HEATER KW/STEPS ELECTRICAL ACC CFM *E.S.P. HP VOLT/PH MCA MOCP FCU01000 TRANE BCHC036B2 130 1200 0.5 1/2 8/2 208/1 53.4 60 T FCU02000 TRANE BCHC036B2 150 1160 0.75 1/2 8/2 208/1 53.4 60 T FCU03000 TRANE BCHC036B2 50 1350 0.5 1/2 8/2 208/1 53.4 60 T FCU04000 TRANE BCHC054B2 50 2000 0.5 1/2 8/2 208/1 53.4 60 T EVAPORATOR -CONDENSING UNIT MARK MFG. CLG. CAPACITY EVAPORATOR CONDENSING UNIT LBS AMB TEMP SENS TOTAL CFM EDB EWB APD MODEL # V/PH MCA MOCP CON 161 10 TRANE 27.2 31.7 1200 76.6 62.9 - 4TTA3042 208/3 18 30 200 95 CON17120 TRANE 29.8 39.0 1160 77.8 64.8 - 4TTA3048 208/3 18 30 210 95 CON 18130 TRANE 29.8 39.0 1350 77.8 64.8 - 4TTA3048 208/3 18 30 210 95 CON 19140 TRANE 43.5 55.5 2000 75.0 63.0 - 4TTA3060 208/3 21 35 230 95 REVIEWED FOR 7DE COMPLIANCE APPROVED FEB 2 7 2014 VY t City of Tukwila BUILDING DIVISION MECHANICAL DRAWING INDEX NUMBER DRAWING .TITLE MO.1 MECHANICAL SYMBOLS, NOTES, SPECIFICATIONS, & SCHEDULES M1.1 MECHANICAL DEMOLITION PLAN M2.1 MECHANICAL PIPING PLAN - LEVEL 1 M2.2 MECHANICAL PIPING PLAN - ROOF M3.1 MECHANICAL DUCTWORK PLAN M7.1 MECHANICAL DETAILS M7.2 MECHANICAL SECTIONS AND DETAILS 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 r ISSUES &REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT RECEIVED CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER ExPIFIES SEAL Oil .14 SHEET WILE MECHANICAL. SYMBOLS, NOTES, SPECS, & SCH. DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00. SHEET NO. M0.1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. PHASE -PHASE REFRIG. PUMP .MODULE SCHEDULE (OFCI). i n EXISTING ON GRADE EXISTING DOCK HIGH C-48°) r---1 J---- L r -r L DOCK ELEVATI❑N AT - 30" BEL❑W FIN, 1EXIT f r, 7 LJ MECHANICAL LEGEND TO BE REMOVED TO REMAIN EQUIP. DGP, /mot --1 / / L— ■ if- , r\ 1 1 I \ I \ - �7.1.... . - __ fp ■_T r �-. �-. �.-. e1i ■-- f— - \ I I (v) I(�) I 1 / T \�J I I I Lam/ . 1 WOMEN I I.-. I MEN ------ I( 1 I( 11----- -sr 01 ❑FFICE 1 I ---.-1 1---- I //- I ' -if I1 ) \ --1- - / I1 ( ) ( 1 L.-L_------.1-1--__.-L-.--zILI_I� hi --1-rr--- 1 ❑FFICE❑FFICE `iIl !I I ❑FFICE ❑FFICE -T-r�-• i-1111F-IMINIMM rr 11I PHONE 11 I 01 it—r In I-- Ll--Lii I r II II II _ OFFICE y GEN. ❑FFICE J13 ici L — ❑FFICE II I'1L /I / I -- 11=-d 4 i L -II II �J r PRINT/C❑PY r RECEPTI❑N EXIT .o. MECHANICAL DEMOLITION PLAN SCALE. 1/8'-1-0' J r I ■ ❑FFICE 18 II / J L---� ❑FFICE i GENERAL NOTES 1. REFER TO SHEET MO.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REMOVE ALL DUCTWORK, TERMINAL BOXES, AND DIFFUSERS WITHIN SCOPE OF WORK. KEYED NOTES 01 DEMO ALL EXISTING DUCTWORK IN THIS AREA. 02 DEMO DUCTWORK THRU ROOF TO EXISTING ROOF TOP UNIT ABOVE. DEMO ROOF TOP UNIT. CAP AND SEAL CURB. 03 DEMO EXHAUST FAN ON ROOF AND ALL CORRESPONDING DUCTWORK. CAP AND SEAL CURB. 0 0 141 AREA OF WORK REVIEWED FOR ODE COMPLIANCE APPROVED FEB 2 7 2014 City of Tukwila BUILDING DIVISION Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 Na 1 ISSUES & REVISIONS Date 02/17/2014 Description ISSUE FOR PERMIT RECEIVED• CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER SHERTTITLE MECHANICAL DEMOLITION PLAN DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SFIDETNQ 1.1 KEYPLAN PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. FCU03000 FCU04000 PA-2 PA-1 I C0N14181 co Cq CD 1 v CD CEN02000 (600KW) MESA On() 1-RON I EXF01000 AlSA1MLsBlAr b 0001 nnn o00 oC 0> oc oO FRONT FRdNT MBCA1000 LJPSAj1 0 00 CL ao 1-1/2"PCD FRONT G1B01030 FRONT FRONT FRONT 1- D LL 0 0 0 0 z w C0N13171 GSB02000I FRONT FRONT FRONT BCC100dJPSC100d BATT. BATT.1 II ABCD100i FRONT FRONT ! I' 1000MOPC I,000 1000 I FRONT 11 JPSD100 FRONT FRONT FRONT HOT AISLE PDUG'?1000 100. 10( 1 10. 100. 1100. 1 100. 1100. i 100. 1100. 1100. 1 1 211 3; 4( 5 6 1 7 8 I 9 10 ! 1 I 1 1 1 ? I I I 1 1 COLD AISLE MSBO11000 200. 204 200. 200. 200. 200. 200. 200. 200. 200. 200.1 200. 1 21 3 4 5 6 7 8 9 10 11 I 12 SCALE. 1/8'-1'-0' COLD AISLE T T--r-- -r--TT7--7" 400.1400.1 00.1400. 1 400. 1400. 1400.1400.1400. 1 400. 1 400. 400.1400. 1400.14 .1400.1 1 1 1 2 1 13 1 4 1 5 1 6 1 7 1 8 19 1 10 1 11 1 12 1 13 1 14 l 1 1 16 1 L__L 1 1 1J_ J_J_ J_J_J-J_J_J-J-J_J-J HOT AISLE -r- TTTTTTT�T-I TTTTT 1500.1500.1j 00.1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.1500.15 0.1500.1 1 1 1 2 I I3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 13 1 14 1 1 16 1 L_LJ J-J.._J-J__L J-_L_J_J--L-L.__L_J i TT 600.1600.1 00. 1600. 121I34 COLD AISLE T T T T T T T 1600.1600.1600.1600.1600.1600.1600.1600. I 5 1 6 1 7. 1 8 1 9 1 10 1 11 1 12 L L J- _L_ I _i- J- J_ HOT AISLE i-T TTTTT-TTTT 1700.1700.17?00.1700. 1 700. 1700.1700.1700.1700.1700.1700. 1700. 1 1 1 2 1 13 1 4 1 5 1 6 1 7 1 8 1 9 1 10 1 11 1 12 1 LJ_J+J- 1 J-J-J-! J-J_J- 1 COLD AISLE m -T- -T- T T I T T T T T TIT -1 800.1800.1800.1800. 800. 18,00.1800. 1800.1800. 1800.1800. 1800.1800. 1800.1800. 1800.i 1 1 1 2 1 I3 1 4 1 5 1 6 1 7 1 8 1 9 1 10 111 1 12 1 13 114 1 1 16 1 LJ__I_i.J-J-J_._L_L_L_J__I_JJ-J-J_IJ_.__J MECHANICAL LEGEND H HOT GAS REFRIG. PIPING LIQUID LINE REFRIG. PIPING PUMPED CONDENSATE PIPING ---- HUMIDIFIER WATER PIPING ter---= WH-1 JB-1 1-1/2"PCD WC-1FD-1 /1 LAV-1 CRA10000 GENERAL NOTES 1. REFER TO SHEET MO.1 FOR ALL SYMBOLS ON THIS SHEET. 2. REFER TO SHEETS M7.1 AND M7.2 FOR INSTALLATION DETAILS AND SECTIONS. 3. ALL EQUIPMENT AND PIPING SHALL BE SEISMICALLY BRACED IN ACCORDANCE WITH LOCAL CODES. 05. 06 07 08 09 KEYED NOTES ROUTE 3/4"PCD AND REFRIG HOT GAS AND LIQUID LINE DOWN WALL TO CONNECT TO CRAC CONNECTIONS. REFER TO SECTION ON M7.2. ROUTE REFRIG HOT GAS AND LIQUID LINES UP THROUGH ROOF PENETRATION AND ROOF HOOD TO CONDENSING UNITS ON ROOF. COORDINATE ROUTING WITH ELECT CONTRACTOR FOR CONTROL AND POWER CONDUITS. REFER TO M2.2 FOR CONTINUATION. REFER TO M7.1 FOR ROOF HOOD DETAIL PROVIDE 3/4"PCD VALVED AND CAPPED FOR INSTALLATION OF FUTURE CRACS. CONNECT 3/4-"PCD, AND REFRIG HOT GAS AND LIQUID LINES TO CRAC UNIT CONNECTIONS. CONNECT REFRIG HOT GAS AND LIQUID LINES TO ECONOPHASE REFRIG PUMP UNIT. REFER TO SECTION ON M7.2. CONNECT REFRIG HOT GAS AND LIQUID LINE AND CONDENSATE TO FAN COIL UNIT ABOVE CEILING. ROUTE 2"PCD DOWN TO FLOOR DRAIN. SLOPE PCD 1/8" PER FOOT TOWARDS FLOOR DRAIN. ROUTE REFRIG HOT GAS AND LIQUID LINES DOWN ALONG EXTERIOR WALL TO CONDENSING UNIT. KEYPLAN AREA OF WORK REVIEWED FOR CODE COMPLIANCE APPROVED City of Tukwila BUILDING DIVISION Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 No. c V, ISSUES & REVISIONS Date 02/17/2014 Description ISSUE FOR PERMIT RECEIVED CITY OF TUKWILA FEB 2 0 2014 NTER f ExPIRES SHBETTTTLE MECHANICAL PIPING PLAN - LEVEL 1 f DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHSETNO M2.i PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN - CONSENT OF BURR COMPUTER ENVIRONMENTS, -INC. MECHANICAL LEGEND. H HOT GAS REFRIG. PIPING LIQUID LINE REFRIG. PIPING PUMPED CONDENSATE PIPING --- HUMIDIFIER WATER PIPING — ON20130 ■ CON19140 CON01011 CON02012 CON03021 CON04022 CON05031 CON06032 1 1 J 1 CON07041 1 , I L `:0 i J r CON08042 ( 11 (,( \1 G Y*i\l j J 1 I I( ,11111 to li L } r---� 5.11 ((( .all\ (y(ttilll L!'r��i 11111 CON09041 CON10042 7 CON11061 CON12062 ((11 ((( ,11111 J CON15120 1 CON17010 1 1 J CON18091 1 MECHANICAL PIPING PLAN -ROOF SCALE' 1/8'-1-0' 06 GENERAL NOTES 1. REFER TO MO.1 FOR SPECIFICATIONS, SYMBOLS, AND LEGENDS. 2. COORDINATE ALL ROOF PENETRATIONS WITH STRUCTURAL ENGINEER AND BASE BUILDING WARRANTIED ROOFING SUBCONTRACTOR. 3. ALL REFRIGERANT PIPING SHALL BE INSULATED AND WITH ALUMINUM JACKET. KEYED NOTES 01 02 03 04 05; PROVIDE AND INSTALL PIPING ROOF HOOD. COORDINATE SIZE OF ROOF PENETRATION AND ROOF HOOD WITH ELECT CONTRACTOR. REFER TO DETAIL ON M7.1. ROUTE INSULATED REFRIGERANT HOT GAS AND LIQUID PIPING DOWN THROUGH ROOF PENETRATION AND ROOF HOOD. REFER TO M2.1 FOR CONTINUATION. CONNECT REFRIGERANT HOT GAS AND LIQUID PIPING TO NEW CONDENSING UNIT AND REFRIGERANT RECEIVER CONNECTIONS. REFER TO MANUFACTURER PIPING SCHEMATIC AND INSTALLATION INSTRUCTIONS. CONNECT REFRIGERANT HOT GAS AND LIQUID PIPING TO NEW CONDENSING UNIT. REFER TO MANUFACTURER PIPING SCHEMATIC AND INSTALLATION INSTRUCTIONS. ROUTE REFRIGERANT PIPING ON DURA-BLOK MODEL DB630 ROOFTOP PIPE SUPPORT. REFER TO SPECIFICATIONS FOR SPACING. 06 8"0 OUTSIDE AIR DUCT UP THROUGH ROOF TO ROOF CAP WITH BIRDSCREEN AND 12" PREFAB INSULATED ROOF CURB. COORDINATE WITH GEN. CONT. AND WARRANTIED ROOFING SUBCONTRACTOR. REVIEWED FOR CODE COMPLIANCE APPROVED FEB 27 2014 City of Tukwila BUILDING DIVISION Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 G.� W U) ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT RECEIVED CITY OF TUKWILA FEB 202014 PERMIT CENTER onti* SHEETTITLE MECHANICAL PIPING PLAN ROOF DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SEIEETNQ M2.2 KEYPLAN PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. fff- 12x8 2500 12x8 300 0 X CD 12x8 3000 FCU04000 8"OA DUCT FCU03000 &"OA DUCT TO FCU04000 L) 112x8 300 0 Y 12x8 300 (TYP.2) I GENO1000 GEN02000 (600KW) (600KVV) 0 00 00 N 0 z w CON 14181 0 200E O LO U 0 EXF01000 28X26 32X20 2100 (TYP.3) HOT AISLE D 0� 0 0 0 0 • 0 z w CON1.3171 1 100. 100. i 100. 1 100. 100. 100. 100. 100. 100. 100. 10D. 100. 1 1 2 13 4 I 5 6 7 8 9 10 11 1f COLD AISLE 200. 200. 200. 200. 200. 1200. 200. 200. 200. 200. 1200. 200. 1 2 1 13 1 4 5 6 7' , 8 9 10 11 12 300. 1 300. 300. 300. 300. 1300. 300. 300. 1 300. 300. 300. 300. 1 2 1 13 1 4 1 3 1 6 I% 1 8 1 9 I 10 1 11 A HOT AISLE I ' CGLD AISLE ' a • of 1 1 --i------- n-1 • 0 400. 400.1400.1 00.'400.1400. 400. 400. 400. 400. 400.'400.1400.1400. 400. 400.1 1 2 3 11 4 5 16 7 8 9 10 11 12 13 1 14 15 16 i L _L_ l� -f 1 L - L_ - L L L_ L _ L HOT AISLE • o 500. 5001500. 1'�00_ 1500. 500. 1500. 500. 500. j500. 1500. 500. 500. 1500. 500. 5 0. I 1 2 1 3 114 1 5 6 7 8 9 110 111 12 13 14 15 116 1 I � !! L L L ! L L f COLD AISLE f I I f f I o7 111 f f I I(De )1 COLD AISLE 0 0 --I-1-1 /1 O o CC 800. 800. 800. 1800. 800. 800.'800. 800. II800. 1800. 800. 800. 800. �( 00. 800. 8 0. 1 1 2 3 1 4 5 6 7 8 9 10 11 12 13 L14 15 116 1 � I •' m t.0 0_ o 0 CD 600. 600. 600. 1600. 600. 600. 600. 600. 600. 600. 1600. 600. 600. 600. 600. 600. 1 2 3 114 5 6 7 8 9 10 111 12 13 14 15 16 ---i1 700. 700. 5 6 HOT AISLE 32X20 2100 (TYP.3) \TO `FC FCU200 8"OA DUCT C I I I L��, FULL SIZE INTERNALLY LINED 'RETURN AIR BOOT (TYP.) w i 1 m L _ MECHANICAL DUCTWORK PLAN SCALE' 1/8•-1'-0• 10x141 EXFO2000' 14x12 Cli A09000 12x12 580 FCU2000 12x 12 12x12 14x14 110 INLET SIZING CHART ROUND NECK SIZE CFM RANGE 6°0 0 - 120 8"4 121 - 220 10"0 221 - 360 12"0 361 - 560 14"0 561 - 800 GENERAL NOTES 1. REFER TO SHEET MO..1 FOR ALL SYMBOLS .ON THIS SHEET. 2. REFER TO SHEET M7.2 FOR DETAILS AND SECTIONS: 3. ALL ROOF PENETRATIONS SHALL BE COORDINATED WITH STRUCT. ENG. ALL ROOF WORK TO BE DONE BY GC WITH WARRANTIED ROOFING SUBCONTRACTOR. KEYED NOTES 01 PROVIDE AND- INSTALL BUSKIN ELF375D EXHAUST AIR LOUVER WITH MINIMUM 1.0 SF FREE AREA. COORDINATE LOCATION WITH LANDLORD AND STRUCT ENG. 02 ROUTE 8" DIA. OUTSIDE AIR DUCT UP THROUGH ROOF TO MUSHROOM CAP OUTSIDE AIR. INTAKE WITH 12" INSULATED ROOF CURB AND BIRDSCREEN. PROVIDE MOTORIZED DAMPER TO OPEN WHEN UNIT IS 'ON' AND CLOSED WHEN UNIT IS 'OFF'. 03 TWO(2) 56x36 FRAMED RETURN AIR OPENINGS BY OTHERS. PROVIDE AND INSTALL 1-1/2" ANGLE IRON FRAME WITH .3/4" EXPANDED METAL TYPE GRATE MOUNTED ABOVE DATA CENTER CEILING IN FRAMED OPENINGS FOR- ALL NEW AND FUTURE CRACS. COORDINATE LOCATIONS OF NEW AND FUTURE CRAC RETURN AIR OPENINGS WITH GEN CONT. REFER TO DETAIL 03/M7.2. 04 TWO(2) 56x24 FRAMED SUPPLY AIR OPENINGS BY OTHERS. PROVIDE AND INSTALL SHEET METAL BLANK OFF PANEL AT ALL FUTURE CRAC OPENINGS. COORDINATE LOCATIONS OF NEW AND FUTURE CRAC SUPPLY AIR OPENINGS WITH GEN. CONT. REFER TO DETAIL 03/M7.2. 05 PROVIDE AND INSTALL 12x8 SUPPLY AIR OPENING WITH GRILLE AND FIRE DAMPER. ABOVE DATA CENTER CEILING. 06 PROVIDE AND INSTALL 12x8 PRESSURE RELIEF RETURN AIR OPENING WITH GRILLE AND FIRE DAMPER ABOVE DATA CENTER CEILING. 07 GENERAL CONTRACTOR TO PROVIDE FLOOR SUPPLY GRILLES AND CEILING RETURN GRILLES IN DATA CENTER AREA. KEYPLAN REVIEWED FOR :CODE COMPLIANCE APPROVED - FEB 2 7 2014 City of Tukwila BUILDING DIVISION Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 U 3 W co U ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT RECEIVED FEB 2 0 2014 PERMIT CENTER 1• kiPsts SHEETITILE MECHANICAL DUCTWORK PLAN DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SEIEErNO M3.1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. J SUPPLY AIR DUCT SPIN -IN TAP WITH VOLUME DAMPER OPENING IN STUD WALL FOR DUCT PENETRATION SHALL HAVE A STUD FRAME ON ALL SIDES. RETAINING ANGLE SHALL BEAR ON STUD FRAME. ! }�r►���1 RATED WALL OR PARTITION I � CONNECT. SLEEVE TO DUCT WITH SLIP JOINT N \ INSULATED FLEX DUCT.��� MAX. 8 FT. LENGTH DAMPER BLADE ASSEMBLY WITH��� DUCT TRANSITION DEMISING WALL OR RATED PARTITION SHEETMETAL SLEEVE FILL VOID WITH APPROVED NON-COMBUSTIBLE MATERIAL (ROCK WOOL INSULATION). AT RATED PARTITIONS, SEAL BOTH ENDS OF• OPENING WITH APPROVED FIRE -CAULK ”r J UL LISTED FUSIBLE LINK - J AL; / i (AIR FLOW %i \r----- :!:l:•! Nam:1111111111111101111111111) STAINLESS STEEL DRAWBAND WITH WORM GEAR TIGHTENING SCREW. CLAMP INNER r — — —, SIDEWALL SUPPLY AIR GRILLE \, 1 DUCT LINER TO GRILLE COLLAR. SEAL. OUTER 1 1 VAPOR BARRIER TO BACK OF GRILLE/DUCT. SEE SPECIFICATIONS FOR TYPE OF TAPE, FLEX DUCT. , ACCESS DOOR SPECIFICATIONS AND SIZE. IN DUCT. REFER TO FOR DOOR TYPE -..64.- - '•" ESCUTCHEON PLATE ON PIPES PIPING CEILING SCHEDULED AIR DEVICE NOTES: 1-1/2"x1-1/2"x1/8" SEE NOTE. RETAINING ANGLE. EXPOSED WITHIN ROOMS li 0: PIPING AT INTERIOR WALL NOTE: SUPPORT THAT LIGHT TILE. 0 : SA .GRILLE FLEX IT DOES FIXTURES, DUCT NOT KINK, CEILING CONNECTION FROM STRUCTURE SAG OR SUPPORT REST TEES SO ON OR 1. PROVIDE UL 2. INSTALL DAMPER LISTING. 3. EXTEND SLEEVE 4. PROVIDE EXPANSION FOOT IN BOTH DIRECTIONS. 5. PROVIDE MINIMUM ANGLES TO SLEEVE MINIMUM OF 1". 0 DUCT LISTED DAMPER AND SLEEVE BEYOND SPACE 1-1/2" IN ACCORDANCE AND SLEEVE IN ACCORDANCE WALL MAX. PER MANUFACTURER'S x 1-1/2" WITH FIRE IN ACCORDANCE 6 INCHES. x 1/8" RETAINING MANUFACTURER'S WITH UL 555. WITH MANUFACTURER'S INSTRUCTIONS INSTRUCTION, BUT NOT ANGLE ON TOP, INSTRUCTIONS. DAMPER LESS THAN BOTTOM ANGLES SHALL NOT TO VOID UL 1/8" PER LINEAL AND SIDES. ATTACH OVERLAP WALL A NOT TO SCALE NOT TO SCALE NOT TO SCALE SHOULDER BOLT NOTE: TYPICAL MANUAL MAIN SUPPLY RETURN EXHAUST OR DUCT = ELEVATE A/C UNIT SUFFICIENT DISTANCE ABOVE FINISHED FLOOR OR ROOF TO ALLOW FOR INSTALLATION OF TRAP WITH ADEQUATE DIMENSIONS TO WITHSTAND SYSTEM OPERATING PRESSURE. COORDINATE WITH DETAIL FOR A/C UNIT MOUNTING. VENT SEE SPECIFICATIONS FOR PIPING MATERIAL �• CLEAN OUT PLUG UNION TEE DRAIN PAN CONNECTION VOLUME DAMPER 45' SPIN -IN FITTING WITH MANUAL VOLUME DAMPER SUSPEND (MIN) LOADS GRAVITY UNIT FROM WITH 4 RODS RATED FOR POINT OF FAN. BACKDRAFT DAMPER CLAMP /0 *ill..., V. .♦ `♦�!• .i- ''Ip,. •STRUCTURE +ii•�•!, •-,, +i• +��.�y • �� ►♦♦♦, •: 4 �•. ,����:!�� ti44���•�••�;.!+' REFRIGERANT PIPE PIPE INSULATION CUSHION / / `' /-, I n '; I NEOPRENE VIBRATION ISOLATORS H TEE S I W III L U I I �,I;� i FULL SIZE EXHAUST AIR -FLEXIBLE DUCT CONNECTOR �- FULL CONNECTION PIPE II UNISTRUT �, SIZE - MIN. 1-1/4" GRILLE. COORDINATE WITH I/ o o ELBOW - EXHAUST FAN PHYSICAL ROOF DIMENSIONS. REFER TO AIR DEVICE SCHEDULE. E , \ \ TYP. ROUND I I / TAKE -OFF AIR I 1 \ BOTTOM ROUTE PIPE TO NEAREST FLOOR DRAIN AS SHOWN ON PLANS FLOW I NOTES: 1) 2) ON \--I DURA BLOK RUBBER COORDINATE AND ELECT ALL UNISTRUT AND HARDWARE SPACING OF SUPPORTS THE SMALLEST DIAMETER ROOF PIPE MODEL DB6 ROOF BASE. NO ROOF LENGTH OF SUPPORT CONDUIT REQUIREMENTS. SHALL BE PER SPECIFICATIONS. PIPE SUPPORTED SUPPORT PENETRATION GALVANIZED. BY PIPE THE WITH SUPPORT SUPPORT REQUIRED. REFRIG SPACING RACK. WITH PIPING SHALL BE BASED TYP. RECTANGULAR TAKE -OFF. USE SMACNA 45' ENTRY FITTING t/, - \ 0 DUCT L = 1/4W (4 MIN. BRANCH TAKE OFF HINGED 02 INLINE FAN ACCESS CABINET PANEL FAN DIRECT DRIVE MOTOR REFER TO FLOOR PLAN FOR DUCT SIZE. PROVIDE TRANSITION AS NECESSARY. TOTAL HEIGHT OF TRAP= X+H+ ( 1 1/2 x PIPE DIAMETER ) FOR DRAW THRU UNITS FOR BLOW THRU UNITS X= MIN. 1/2 H= NEGATIVE 0 CONDENSATE H (PREFERRED STATIC PRESSURE X=H) X= FAN +1" H= MIN. DRAIN STATIC PRESSURE 1" PIPING +1 " NOT TO SCALE NOT TO SCALE FAN_INLINE.DWG NOT TO SCALE NOT TO SCALE m MIN. FROM OF BETWEEN CD ,-, z N CURB; \ ............. �\ 41, 4" CLEARANCE PIPE MIN. PIPES I • . TO ' .TOP " 2 - -- ,; I , ° ...,�•�•0" , �- S�DAF + l �, � �� , �� ��' , ';. :.: ` �` / '_+:4 `'' ''���.. �� _�� . =` .-4t '� - > �� - 1 i I i� 4 •�:. - - z •".::: •��� STAINLESS STEEL ENCLOSURE WITH REMOVABLE TOP. CROSSBREAK OR SLOPE FOR DRAINAGE. INSTALL 1" FOAM BOARD INSULATION TIGHT TO INSIDE WALLS OF ROOF PENETRATION STAINLESS STEEL COLLAR SLOPE PIPES DOWN AND AWAY FROM HOOD REMOVABLE STAINLESS STEEL COUNTER -FLASHING ADHERED MEMBRANE FLASHING WELDED SEAM SEALANT (IF REQUIRED FOR THE SPECIFIC SYSTEM) GASKEIED FASTENERS - SHOULDER BOLT PREFORMED THERMOPLASTIC PIPE WITH GALVANIZED CLAMP SIZED PIPE SIZE. CUSH-A-CLAMP, VIBRACLAMP, SADDLE TO MATCH OR EQUAL. SPLIT RING TYPE HANGER ROD CLEVIS HANGER TYPE THREADED ROD HANGER AS SPACING OF HANGERS PER SPECIFICATIONS REQUIRED TURNBUCKLE AS REQ'l • - 1�1 • - - ,�•i•i•"I•lr . . .'i.•ii•%iii0 ''.;,p. '�•••* REFRIGERANT PIPE PIPING ��� im CLAMP m, •••,'' 0* 41 •• ►•.,...•.. • ��Q ►ii �i�i !i•i' ,... ... .+.�...���•.�!, /•�•,•'' • , ��.� }i•�� ��ii II, 1�ii ►.O'1 ,.... .�.+ •++.•ii❖ii!� PIPE INSULATION CUSHION m, i .� ,• + •. 0 i CI ii .�.�••''1+�.0 I +i. , .� .+. .�. - , `•rips .�IP ♦ 0•s .. ►+i+ �i i i ♦•+•4 •i �`Mal ���► l's.� � .•+ 4 • . II ♦+•i`,O+ . • •+•.�i�i•!/ '•-'.�O • •%i...y ; _H� -t - JE I ; --- ;�p' S �.�:❖::�.+ ,�i++ •••:* FLOOR INSULATION UNISTRUT CUT HANGER ROD FLUSH ��� ��� SHEETMETAL SADDLE i� �+ " • �• MINIMUM 8 LONG \�*s- - ./- '�� him �� �•��� }♦ ♦• •� •� •.•� !..,_.�•�!.' �, j , r UNISTRUT BOLT UNISTRUT TO FLOOR. SHIM UNDERSIDE AS WITH BOTTOM NUT. PROVIDE FULL CIRCUMFERENCE �l!.!.!• NOTES: 1) THIS DETAIL APPLIES TO INSULATED AND UNINSULATED COPPER SPECIFICATIONS FOR INSULATION REQUIREMENTS. 2) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. PIPING. REFER TONOTES: 12 LONG SECTION OF HIGH COMPRESSION STRENGTH CLOSED -CELL INSULATION AT EACH HANGER POINT 1) ALL UNISTRUT AND HARDWARE 2) MAXIMUM ALLOWABLE SPACING SHALL BE GALVANIZED. OF HANGERS: NOTES: 1) 2) ON 0 ALL UNISTRUT SPACING OF THE SMALLEST REFRIGERANT AND HARDWARE SHALL SUPPORTS PER SPECIFICATIONS. DIAMETER PIPE SUPPORTED BE REQUIRED GALVANIZED. SUPPORT BY THE RACK. PIPE TO KEEP LEVEL SPACING SHALL SUPPORT BE BASED SHEET -METAL FLASHING RECEIVER ``� �� /1''• li% •• ki •• (MINIMUM 2 PER SIDE) ADHESIVE 2x6 MIN. WOOD NAILER 4+. 11 4 BONDING PLATES AND ATTACHED TO SUBSTRATE; OVERALL THICKNESS TO MATCH INSULATION SEAM �FASTENERS BOARD 3) THE 4) 0 - MAXIMUM SMALLEST COPPER PROVIDE MULTIPLE ALLOWABLE DIAMEILR PIPE: HANGER SPACING Y" TO 2" TO AT ALL OF PIPE SUPPORTED 1Y" - 5'-0" 2)c - 8'-0" CHANGES HANGERS OF PIPE (HANGER SPACING BY THE RACK): O.C. O.C. DIRECTION. HANGER SHALL BE BASED ON 0SINGLECity 3) STEEL COPPER CAST PROVIDE PIPE: PIPE: IRON PIPE: HANGER Y" 2" Y2" 2" ALL AT TO 1Y" TO 21/2" TO 1Y4" TO - 10'-0" ALL - - - 5'-0"' 2 " - CHANGES 7'-0" 10'-0" 8'-0" O.C. OF O.C. O.C. O.C. O.C. DIRECTION. I REVIEVVED FOR CODE COMPLIANCE APPROVED FEB 2 7 2014 of Tukwila BUILDING DIVISION SINGLE -PLY ROOF MEMBRANE COVER AND THERMAL INSULATION 10 ROOF PENETRATION ROOF DECK NOT TO SCALE NOT TO SCALE NOT TO SCALE NOT TO SCALE Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 J ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT RECEIVED CITY OF I UKVVILA FEB 2 0 2014 PERMIT CENTER J o2tt�1 dt !RES SHEETTTTLE MECHANICAL DETAILS 1 DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SEFETNO PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. ROOF i • (2)1-3/8" HOT GAS (2)7/8" LIQUID LINE 3/4"PCD —� 3/4"HUM COMPRESSOR ASSEMBLY FIELD WELD UNIT TO FLOOR STAND. REFER TO STRUCT. PRE -FABRICATED SEISMIC FLOOR STAND. REFER TO STRUCT. OFCI LEAK DETECTION MODULE FINISHED FLOOR OFCI LEAK DETECTION CABLE. SECURE TO FLOOR. TWO -TIERED UNISTRUT PIPING SUPPORT CRAC (OFCI) (2)56"Wx36"H RETURN AIR OPENINGS FOR EACH CRAC UNIT. 1-1/2" ANGLE IRON FRAME AND 3/4" EXPANDED METAL WELDED TO INSIDE. FRONT ELEVATIO\ DOWNFL0IN GRAGUNIT NOT TO SCALE FILTER ASSEMBLY ELECTRIC BOX ASSEMBLY (2)24"Hx56"W SUPPLY AIR OPENINGS BELOW RAISED FLOOR. 2x2x1/8 GALV ANGLE IRON; SECURE TO FLOOR AND CAULKI .I OFCI SEISMIC ANCHORING. REFER TO STRUCT. (2)56"W OPENING SECURIT LA (2 uc FLEXI (2)2 OPEN 30" ROOF \ i//"\\ j//( \\ )//' 4"Hx56"W \ / \ if -\\ / \1/4 ,///' \ j//( \ RA I TWO -TIERED UNISTRUT PIPING SUPPORT 1 REFRIGERANT PIPING o 0 0 0 0 A o o f a m A = - x36"H RETURN AIR ✓I--■- ;S WITH EXPANDED METAL Y GRATES FOR EACH UNIT.--' (-IN CEILING ►1-1/8" HOT GAS, (2)7/8" IUID, AND 3/4" PCD DATA CENTER REFRIGERANT PIPING = I a m 0 0 0 A 0 0 0 0 HUM PIPING PCD PIPING LIGHT FIXTURE N-OFCI FILTER ASSEMBLY. FILTERS REMOVED THROUGH FRONT OF PLENUM. MECHANICAL CORRIDOR CRAC �-EC AINI TOREMIN INSIDETHEIR UNIT. SHIPPEDFANS POSITION BLE DUCT CONNECTION SUPPLY AIR INGS BELOW RAISED FLOOR. RAISED FLOOR �+ PROGRAM FANS TO ROTATE UPON SHUTDOWN TO PREVENT BACKDRAFT. INSULATED SHEET METAL PLENUM WRAPPED AROUND SEISMIC FLOOR STAND. OFCI LEAK OFCI LEAK DETECTION DETECTION MODULE CABLE I SA _ CONCRETE FLOOR SHEET METAL BLANK OFF PANEL SECURED TO FRAME FOR ALL FUTURE CRACS. SIDE ELEVATION SECURE GALV ANGLE IRON; SECURE TO FLOOR AND CAULK. ROOF UNISTRUT MOUNTED TO WALL SUPPLY AIR DUCT HEADER 7/8" HOT GAS LINE 5/8" LIQUID LINE OFCI LEAK DETECTION CABLE. SECURE TO FLOOR. - FINISHED FLOOR t UPFLOW CRAC NOT TO SCALE PIPES PENETRATE INTO LOADING DOCK AREA. FIRE CAULK PENETRATIONS. REFER TO FLOOR PLAN FOR CONTINUATION. -3/4" PUMPED CONDENSATE LINE MOTORIZED BACKDRAFT DAMPER 30/26 SUPPLY DUCT /-FLEXIBLE CONNECTION PROVIDE REFRIGERANT SHUT OFF VALVES. 0 0 AIR-COOLED CONDENSER Oi a (OUTDOORS) LEAK DETECTION MODULE /7-2x2x1/8 GALV ANGLE IRON; SECURE TO FLOOR AND CAULK. NEOPRENE VIBRATION ISOLATION PADS AIR-COOLED CONDENSER (OUTDOORS) HOT GAS LINE (2) PROVIDE REFRIGERANT SHUT OFF VALVES --r LIQUID LINE (2) V ECONOMIZER REFRIGERANT PUMP COOLING COIL -1� F- 7�-x-�,r-�c-x-x�rx�rr:�c-Ic xxxxxxxxxxxxx xxxxxxxxxnn. ennhnnnn�n��n6�� CRAC UNIT (INDOOR) L COMP. 110 (2) COMP. (2) 110 --J 1 r r 7/8" HOT GAS, 5/8" LIQUID, AND 3/4" PCD PRE -ACTION RM OFCI LIEBERT DSE RECEIVER SUPPLY AIR DUCT HEADER SUPPLY AIR GRILLE WITH MANUAL VOLUME DAMPER MOTORIZED BACKDRAFT DAMPER �FLEXIBLE CONNECTION PIPING SUPPORTS (TYP.) UPS ELECT. RM FINISHED FLOOR ROOF PIPING PENETRATION. CURB AND HOOD PROVIDED AND INSTALLED BY GC. REF DETAIL ?/M7.1. TWO(2) SETS OF REFRIG PIPING CIRCUITS. REFER TO MANUFACTURER AND DRAWINGS FOR QUANTITIES, SIZES, APPURTENANCES, AND ROUTING DETAILS. h J'I CONDENSATE PIPING ROUTE TO EXISTING LINE AND TIE IN `-CONTROL WIRING IN CONDUIT BY ELECT CONT. REFER TO ELECT DWGS. RETURN AIR FILTERS CONTROL PANEL SMOKE DETECTOR TIED INTO EXISTING BUILDING FIRE ALARM CONDENSATE DRAIN PAN CONDENSATE PUMP f-MOUNT CRAC UNIT ON SUPPORT STAND. STAND FURNISHED WITH UNIT F MOUNT MOISTURE DETECTION MODULE. -DETECTOR FURNISHED WITH UNIT. RUN HOT GAS PIPING LEVEL OR SLOPE AWAY FROM THE COMPRESSOR (IN DIRECTION OF FLOW). Factory provided internal controls shall control the CRAC and ACC functions to maintain space humidity and temperature set -points and cycle econo-phase refrigerant pumping . sequence. 1) The internal fanoperates continuously. The compressor unloads and cycles on/off as needed to maintain the set -point. The condensing unit fans speed up/down and cycle on/off as controlled by the CRAC control panel. RAISED FLOOR 2) The unit mounted smoke detector shall, upon sensing smoke, shut down the unit and notify the building fire alarm system. The CRAC will restart after the smoke detector has been manually reset. 3) The leak detection system shall, upon sensing moisture, alarm at the unit control panel but will not shut the unit off. FLOOR SLAB DX SYSTEMS -: CRAC SEQUENCE- OF OPERATION AND REFRIGERANT PIPING DETAIL NOT TO SCALE REVIEVVED FOR 1 CODE COMPLIANCE APPROVED FEB 2 7 2014 City of Tukwila UILDING DIVISION Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 X CD UJ V r • ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT RECEIVED CITY OF TUKWILA FEB 202014 PERIVIIT CENTER C r aEs '04.. s SHEET TITLE MECHANICAL DETAILS DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEET NO. 7.2 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. SPLIT RING TYPE HANGER PRINKLER PIPE SPRINKLER PIPE NOTES: 1) ALL UNISTRUT AND HARDWARE SHALL BE GALVANIZED. 2) MAXIMUM ALLOWABLE SPACING OF HANGERS: STEEL PIPE: Y" TO 1Y" - 7'-0" O.C. 2" TO 2Y" - 10'-0" O.C. COPPER PIPE: Y" TO 1Y" - 5'-0" O.C. 2" TO 2i " - 8'-0" O.C. CAST IRON PIPE: ALL - 10'-0" O.C. 3) PROVIDE HANGER AT ALL CHANGES OF DIRECTION. CLEVIS TYPE HANGER SINGLE PIPE HANGER NOT TO SCALE HANGER ROD TURNBUCKLE DEMISING WALL OR RATED PARTITION SHEETMETAL SLEEVE SPRINKLER. PIPE PROVIDE ESCUTCHEON PLATE ON PIPES EXPOSED WITHIN ROOMS. - FILL VOID WITH APPROVED NON-COMBUSTIBLE MATERIAL (ROCK WOOL INSULATION). AT RATED PARTITIONS, SEAL BOTH ENDS OF OPENING WITH APPROVED FIRE -CAULK PIPING AT INTERIOR WALL NOT TO SCALE d- PRE-ACTION ZONE PIPING BACK TO MAIN RISER LOCATION RELEASE CONTROL PANEL ROUTE 2" DRAIN PIPE TO NEAREST FLOOR DRAIN FINISHED FLOOR • ro ��CONNECT TO BUILDING FIRE ALARM OR CENTRAL STATION MONITORING PANEL O AIR SUPPLY COMPRESSOR TO PROVIDE 30 MIN FILL AS PER NFPA 13 REQUIREMENTS COMPRESSOR TO MAINTAIN r STORAGE TANK PRESSURE 2_S 1' VIKING "TOTALPAC-3" DOUBLE -INTERLOCKED PRE -ACTION SYSTEM WITH "N2-BLAST" NITROGEN CORROSION INHIBITING SYSTEM NITROGEN STORAGE TANK PRE -ACTION SYSTEM DETAIL NOT TO SCALE PREACTION FIRE PROTECTION SYSTEM SPECIFICATIONS A. CONTRACTOR SHALL PROVIDE AND INSTALL A COMPLLIL PACKAGED DOUBLE -INTERLOCK PRE -ACTION SYSTEM BY VIKING "TOTALPAC-3" WITH "N2-BLAST" NITROGEN CORROSION INHIBITING SYSTEM OPTION IN ACCORDANCE WITH NFPA 13 AND THE REQUIREMENTS OF THE LOCAL FIRE MARSHALL. B. AFTER ACTIVATION, NO PORTION OF THE FIRE PROTECTION SYSTEMS SHALL BE TURNED OFF, MODIFIED.. OR CHANGED IN ANY WAY WITHOUT THE EXPRESS KNOWLEDGE AND WRITTEN PERMISSION OF THE OWNER REPRESENTATIVE IN ORDER TO PROTECT SYSTEMS WHICH SHALL REMAIN IN SERVICE. C. THE SPRINKLER SYSTEM SHALL BE IN ACCORDANCE WITH NFPA 13. THREADED FITTINGS AND UNIONS SHALL BE USED FOR SIZES UP TO 2". THREADED FITTINGS SHALL BE CLASS 150 ' MALLEABLE IRON OR CLASS 125 CAST IRON IN ACCORDANCE WITH ANSI B13.3. FLANGES SHALL BE CLASS 150 STEEL FLANGES FOR ;THREADED CONNECTION IN ACCORDANCE WITH ANSI B16.5. A UL LISTED . GROOVED PIPING CONNECTION SYSTEM WITH "ROLLED -GROOVES" SHALL BE USED FOR PIPING 2-1/2" AND LARGER. D. ALL PIPING SYSTEM MATERIALS, COMPONENTS AND INSTALLATION SHALL BE IN ACCORDANCE WITH NFPA 13, CODE AND THE REQUIREMENTS OF FACTORY MUTUAL. ALL PREACTION PIPING SHALL BE SCHED 40 BLACK STEEL. E. ALL PIPING SHALL BE INSTALLED PARALLEL OR PERPENDICULAR TO THE BUILDING CONSTRUCTION. ALL PIPING SHALL BE INSTALLED SO AS TO ALLOW ; FOR EXPANSION: F. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE. MANNER AND WHEREVER POSSIBLE, PARALLEL RUNS OF HORIZONTAL PIPING SHALL BE GROUPED TOGETHER ON TRAPEZE TYPE HANGERS. THE USE OF WIRE OR PERFORATED METAL TO SUPPORT PIPES WILL NOT BE PERMITTED. HANGING PIPES FROM OTHER PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL BE AS REQUIRED BY NFPA 13. ALL SPRINKLER PIPING SHALL BE ADEQUATELY SUPPORTED TO AVOID EXCESS STRAIN ON FITTINGS AND JOINTS. G. ALL FIRE PROTECTION PIPING SHALL BE PITCHED TO DRAIN IN ACCORDANCE WITH NFPA 13. PROVIDE VALVES WITH HOSE CONNECTIONS AT ALL SYSTEM DRAIN POINTS. H. PIPING FABRICATION AND SPRINKLER DRAWINGS SHALL BE SUBMITTED FOR ALL SPRINKLER PIPING. PIPE FABRICATION AND SPRINKLER DRAWINGS SHALL BE TO SCALE ON 1/8" SCALE BUILDING FLOOR PLANS AND SHALL INDICATE PIPE SIZE, FITTINGS, VALVES, ACCESSORIES, CONNECTIONS, SUPPORT REQUIREMENTS, PIPE ELEVATIONS AND OTHER INFORMATION REQUIRED FOR COORDINATION WITH OTHER TRADES AND FABRICATION OF PIPING. PIPE FABRICATION AND SPRINKLER DRAWINGS SHALL BE COORDINATED WITH OTHER TRADES AND BUILDING CONSTRUCTION PRIOR TO SUBMITTAL FOR APPROVAL I. ALL FIRE PROTECTION PIPING SHALL BE THOROUGHLY FLUSHED TO REMOVE ANY SLAG OR DEBRIS PRIOR TO BEING TESTED OR PUT INTO SERVICE. SPRINKLER PIPING SHALL BE TESTED WITH AIR PRESSURE PRIOR TO WATER TEST WHICH THEN SHALL BE PRESSURE TESTED FOR 2 HOURS AT PRESSURE IN ACCORDANCE WITH NFPA 13. ADDITIONAL TESTING SHALL BE PROVIDED AS REQUIRED BY LOCAL AUTHORITIES. J. ALL COMPONENTS OF THE FIRE PROTECTION SHALL BE UL LABELED AND FM APPROVED FOR THEIR INTENDED USE. . PROVIDE A COMPLETE SPRINKLER SYSTEM FOR THE FLOOR AND ABOVE CEILING AS NECESSARY THE ENTIRE SYSTEM SHALL BE IN ACCORDANCE WITH NFPA 13 THE CITY BUILDING CODES. L. SPARE SPRINKLER HEADS SHALL BE PROVIDED AND TURNED OVER TO THE S. OWNER'S REPRESENTATIVE AT THE TIME OF SUBSTANTIAL COMPLETION. SPRINKLER HEAD QUANTITIES SHALL BE IN ACCORDANCE WITH NFPA RECOMMENDATIONS AND SHALL BE FURNISHED WITH A WALL MOUNTED METAL STORAGE CABINET WITH AN ENGRAVED NAMEPLATE AND APPROPRIATE INSTALLATION WRENCHES FOR EACH HEAD TYPE FURNISHED. AT THE TIME OF SUBSTANTIAL COMPLETION, THE SPRINKLER SUBCONTRACTOR SHALL EXECUTE AN "INSPECTION AGREEMENT" WITH THE OWNER: THIS AGREEMENT SHALL BE EXECUTED AT NO COST TO THE OWNER AND SHALL INCLUDE FOUR INSPECTIONS OF THE ENTIRE SPRINKLER SYSTEM DURING THE WARRANTY PERIOD, EACH WITH A "REPORT OF INSPECTION" FORM AS DETAILED IN NFPA-13A OR THE NATIONAL FIRE SPRINKLER ASSOCIATION TO THE OWNER. THE FINAL INSPECTION SHALL INCLUDE OPERATION AND LUBRICATION OF ALL VALVES, CLEANING OF ALL ALARM VALVES AND OPERATIONAL TESTING OF ALL SYSTEM ELECTRICAL AND ALARM COMPONENTS, N. SPRINKLER HEADS i) VIKING MODEL B1 "SEMI -CONCEALED" - COORDINATE WITH ARCH. SPRINKLER HEAD SHALL BE UL LISTED AND FM APPROVED WITH WHITE PLATE. . FINAL APPROVAL FOR THIS SPRINKLER HEAD SHALL BE BY THE OWNER'S REPRESENTATIVE. ii) SPRINKLER HEADS SHALL BE 165E RATED. 0, FIRE PROTECTION VALVES VICTAULIC SERIES 705W FIRELOCK BUTTERFLY VALVE WITH BUILT IN TAMPER SWITCH. DUCTILE IRON BODY AND. DISC WITH EPDM DISC COATING. SERIES 705W VALVE IS UL LISTED AND FM APPROVED FOR 300PSI SERVICE. VALVES SHALL BE UL LISTED AND FM APPROVED FOR FIRE PROTECTION USE. FIRE LINE CHECK .VALVE TO 150 PSI i) CHECK VALVES SHALL BE OF A TYPE HAVING IRON BODY, BRASS SEAT AND DISCS, CLEARWAY SWINGING, WITH DRIP CONNECTIONS, DESIGNED FOR 175 POUNDS WATER WORKING PRESSURE. VALVES SHALL BE UL LISTING AND FM APPROVED FOR FIRE PROTECTION USE. 2" AND LARGER GRINNELL/MUELLER NO. A-2120-6. FURNISH WITH ALL REQUIRED TRIM. Q. SPRINKLER ALARM VALVES i) VIKING, SIZE AS REQUIRED SPRINKLER ALARM VALVE WITH RETARD, VARIABLE PRESSURE WITH CLOSED RETARD DRAIN TRIM, FLOW SWITCH (ELECTRIC SPRINKLER ALARM SWITCH), MECHANICAL WATER BELL AND DRAIN AND ALL OTHER REQUIRED TRIM. R. SPRINKLER DELUGE VALVES i) VIKING, SIZE AS REQUIRED SPRINKLER DELUGE VALVE WITH OTHER REQUIRED COMPONENTS FOR A COMPLETE UL LISTED ASSEMBLY FOR PRE -ACTION SYSTEM. T. AIR COMPRESSOR i) VIKING MODEL D2 SELF-CONTAINED SUPERVISERY AIR SUPPLY WITH 120 VOLTS/1PH/1.5 AMPS CONNECTION. PRESSURE GAUGES i) FURNISH AND INSTALL POTTER-ROEMER FIG. NO. 6240 POLISHED BRASS CASE, 1/4" NPT MALE CONNECTION, GLASS ENCLOSED, 0-300 PSI DIAL PRESSURE GAUGES WITH ISOLATION VALVES, AS SHOWN ON SPRINKLER TAP DETAIL: APPROVED MANUFACTURERS ARE AS FOLLOWS: i) SPRINKLER HEADS:RELIABLE, VIKING OR GEM/GRINNELL. ii) FIRE PROTECTION SPECIALTIES: 'POTTER-ROEMER, RELIABLE, VIKING OR GEM/GRINNELL. iii) FIRE PROTECTION :VALVES'. POTTER-ROEMER, STOCKHAM, OR GRINNELL/MUELLER. iv) FIRE PROTECTION TEST/DRAIN VALVES: VICTAULIC OR AN APPROVED SUBSTITUTE. ALL VALVES WHICH EFFECT THE FLOW OF FIRE WATER SHALL BE SUPERVISED. THE SUPERVISORY SWITCHES SHALL BE FURNISHED AND INSTALLED BY THIS CONTRACTOR AND WIRED BY DIVISION 16. SUPERVISORY SWITCHES SHALL BE POTTER ELECTRIC- SIGNAL CO. MODEL OSYS-U OR AN APPROVED SUBSTITUTE. FLOW SWITCHES SHALL BE FURNISHED AND INSTALLED FOR EACH SPRINKLER ZONE BY THIS CONTRACTOR AND WIRED BY DIVISION 16. FLOW SWITCHES SHALL BE GRINNELL/POTTER SWITCH MODEL VSR-D/VSR-T OR AN APPROVED SUBSTITUTE WATER FLOW DETECTORS AND SHALL BE UL LISTED, FM APPROVED FOR PRESSURES TO 300 PSI. THE PRE -ACTION SYSTEM SHALL ALSO EQUIP WITH DRY CONTACT CIRCUIT TO BE FIELD WIRE FROM THE BUILDING FIRE ALARM SYSTEM, AUTOMATIC EMERGENCY POWER. ELECTRICAL TROUBLE AND MAIN ALARM BELLS, MANUAL PULL STATION (EMERGENCY). FIRE EXTINGUISHERS A. PROVIDE AND INSTALL THREE(3) 10 LB. HALOTRON OR FE36 FIRE EXTINGUISHERS. B. HALOTRON IS A "CLEAN AGENT" HYDROCHLOROFLUOROCARBON DISCHARGED AS A RAPIDLY EVAPORATING LIQUID WHICH LEAVES NO RESIDUE. C. ' HALOTRON IS PRESSURIZED WITH ARGON GAS AND IS AN EPA AND FAA APPROVED HCFC BLEND B AGENT APPROVED FOR USE ON CLASS A, B, AND C FIRES. D. HALOTRON IS INTENDED FOR USE IN AREAS SUCH AS COMPUTER ROOMS, TELECOMMUNICATIONS FACILITIES, CLEAN ROOMS, AND DATA STORAGE AREAS. E. COORDINATE LOCATIONS OF FIRE EXTINGUISHERS WITH ARCH. PREACTION FIRE PROTECTION SYSTEM OPERATION A. THE SYSTEM SHALL BE A DOUBLE INTERLOCKED SYSTEM, REQUIRING BOTH A CROSS -ZONE SMOKE DETECTION ALARM AND A LOSS OF AIR PRESSURE. IN THE PIPING SYSTEM BEFORE THE PREACTION VALVE RELEASES WATER TO THE SYSTEM. B. THE FOLLOWING ACTIONS SHALL ANNUNCIATE AT THE PREACTION PANEL AND THE BUILDING FIRE ALARM PANEL: 1) SMOKE DETECTION 2) PIPING SYSTEM AIR PRESSURE LOSS 3) WATER FLOW ALARM THROUGH THE DELUGE VALVE 4) WATER PRESSURE. ALARM ALL ALARM INDICATORS ADDED TO THE EXISTING BUILDING FIRE ALARM PANEL SHALL BE LABELED WITH A "DATA CENTER" PREFIX AND THE CORRESPONDING ACTION ALARM.. C. ALL OF THE PREACTION FIRE ALARM CONTROL PANEL SHALL BE ON THE LIFE SAFETY BRANCH OF EMERGENCY POWER WITH INTERNAL BATTERY BACKUP. THE REMAINING FIRE PROTECTION SYSTEM COMPONENTS SHALL BE ON THE EMERGENCY POWER EQUIPMENT BRANCH SERVED BY NEW PANEL ELA. PREACTION FIRE PROTECTION SYSTEM CRITERIA A. CONTRACTOR SHALL COORDINATE AND CONNECT FIRE ALARM SIGNAL WITH THE BUILDING FIRE ALARM SYSTEM. B. THE SPRINKLER PIPING AND HEADS SHALL BE LOCATED AS REQUIRED. SPRINKLER SYSTEM SHALL BE HYDRAULICALLY DESIGNED AND INSTALLED IN ACCORDANCE WITH LOCAL CODE AND NFPA 13. C. CALCULATIONS SHALL MEET THESE MINIMUM REQUIREMENTS: 0.15 GPM/FT-2 OVER THE MOST REMOTE 2000 FT-2. D. SPRINKLER HEADS SHALL BE RATED AT 165'F. E. SPRINKLER PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH ROLLED GROOVE OR SCREWED FITTINGS. FIRE DRAWING INDEX NUMBER DRAWING TITLE F0.1 -FIRE PROTECTION NOTES, SPECIFICATIONS, & DETAILS F2.1 FIRE PROTECTION SPRINKLER PLAN 10400 Rodgers Road HOUSTON, TEXAS 77070 Ph: 281-374-8644 Fax: 281-374-8992 Gens Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas; TX 75240 Phone: 214/273-1559 CD co F- i ISSUES & REVISIONS No. Date Description 1 02/17/2014 ISSUE FOR PERMIT RECEIVED CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER 1 ................. SHEET TITLE FIRE PROTECTION NOTES,SPECS & DET. I DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEET NO. FO.1 PERMIT AND APPROVAL REQUIRED J PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 0 0 0 GEN01000 (600KW) 11 11 11 11 11 11 1 I 11 11 GEN02000 (600KW) rr LL CD CD CD CD CD r,) co 0 LLI 1 u_ 0 0 z 0 0 0 u3 • rp rT, EXF01000 I 0 m 1 BFP 0 k -2 I PA-1 0••00 D r - L - A Fcuo3oclo * 4,4 4: I I I * * * I I I jt t t t 17- i 1 1 1 1 1 y f + ' A A I i i 1 i i 1 A A : i •i 1 1 1 4( 4( * I I I * * * 1 1 I I . 1 1 * 4' I I I 1 1 i f f f i f + + 1 A A 1 1 i A A A 1 1 i A A A 1 1 1 _ _ _ _.___4. _i_ I 4: 4: 4: 1 1 1 * * * 1 1• 1 4: 4: 1 4, tI 1 1 1 1 ¥ ¥ t 1 1 f f f1 ) 1 1 ' f f T1 1 + fl f 1 I J, A A 1 1 i A A iFCU0400in 1 1 1 i i i I I I * * * I I 1 I I< 4( I< ,LU LU 'ilk CD c) 7J 3>. CO CD cD CD CD CL CD CC 0 I / L 0 CD Lo c:) A F i/ A L./ 21 • * LIJ 04 )1( 14= 11 )1( • 1 Y 1 PRF-ACTIoN SPRINKI ER ZONE 1 - ELECTRICAL ROOM 1 0.7-3-0-017-1 3-00.T3-00.T3-00T3-00.7131 -00.T3-00.T3-00.T3-00.T3-0011-3-00.1 2 ' 3 ' 4 ' 5 ' 6 ' 1 7 ' 8 ' 9 ' 10 ' 11 I 12 ' 1 1 1 1 1 _J_ 1_L _1_ _1_ Ji _L _L _L_ J t I I 1 1 )k I ••• 0.11111•11 J. ;1 1 4- t 1 1 -X- -)( -4 -*-*+*-- If 1 -X- -Y- -X-- --X- • I (---)l- --X-1- I f 1 1 f -T- --1- -T- Tr- -7-- Ti- -T- -T- -T- -T- --1+Iti * i * ff$-r- i I --r- ad 4-00. 1 400. i 400.140at .1400.1400.1 0.1400.1400.1400.1400.1400.14 .1400.i* 11 1 2 i 13 i 4 i Wall 1 7 1 8 1 1 1 10 i 11 1 12 1 13 i 14 1 1 1 16 i 1 * _L 1 4 I t ic 1 I 1 1 I I Pr -1- 1 j -T- --1- -1- --1- -1- ry 1 --1- -I- -T- -1-- -1-1-r- -ly t0.1500., ,00. 1500. 1500. 1500. 1500.1500.1100, 1500.1500.1500. 1 500.1500.1599.1500.1 1 T1121131415161718 4911011111211311411F116 ly f Li_ _L_ _Li_L _L _L_ _L_ _L_ _Ji_ .J_ _L_ _J_ _1_ _1_ _L_1_1_ .J f f A A 1 i A A A i A A A 1 i -i- --i d] i- + 1 + 1 + 1 1 1 11 * * * -T- -T- I -T- --1-- --1-414,-T- -T- -T- TIT --1-- -T-j-T- --I I 0.1600. 1 00.1600. 1600.1600. i 600.1600.100.1600.1600. 1600. 1600.1600. 16 0.1600.1 * 1112131415161718119• 11011111211311411f11611 LT _1_ _iL_ _L_ L_ _i_ _L_ _l_ _J_L_ 1 -I PR -ACTION SPRINKLER ZO E 2 - DATA CENTER J _ dvID-T-. -T- -if --1-- --1-- -T- I -7-- -T-I Y 0.1700.100.1700. i 70 .1700.1700.1 0.17•00.1700.1700.1700. 710.1700.1I.1 I< 1 , . 1 1 1 2 113 1 4• I 5 1 6,7,8,9110,,,12,13ni1 ,, 1.4 ....4:_...L_ _1_ __L_ __L. i 1 1 1 I 1- „1 I + -T- -T- i:1-y--,- -F -AT- -T- -T- --1- -1-- -1-1-1-- 7+ 00.1800. 1800. 1800.1800. 1800. 1800. 1800. 1(4:1)0.1800. 1800.1800.1800.1800. 1800.1800. i • 1 ' 1 2 1 131415161718i, i 10 i 11 1 12 I 13 1 14 i 1p i 16 if J_ _LL ___L_ _i_ __1__ __L_ _1_ _4 __L __L_ _1_ 1 _L_ __L__I__ LU )1( LU )I( LU (1) C:) CD FCU1000 FD- 0 JB-1 WC-1 FD-1 • LAV=1 11 1 )• FD WC-1 LAV 1 rn SK-1 FCU 200 cD) cp co CD CD L° /' t 7- -71 • '//, • L _ RI CRA10000 A / // //) r///// , 14A09000 r-rr :111;1: / //'1 P FIRE SPRINKLER PLAN SCALE. 1/8•01-01 618) LU r-- 0 •GENERAL NOTES 1. REFER TO SHEET F0.1 •FOR SPRINKLER SYSTEM SPECIFICATIONS AND DETAILS. • 2. FINAL DESIGN OF PRE -ACTION SPRINKLER SYSTEM TO BE ENGINEERED BY SELECTED FIRE PROTECTION CONTRACTOR/ENGINEER AND SUBMITTED TO BCEI FOR REVIEW AND APPROVAL AND SUBSEQUENTLY ISSUED TO CITY FOR PERMITTING. 3. COORDINATE LOCATION OF SPRINKLER HEADS IN DATA CENTER WITH LIGHT FIXTURES AND RETURN AIR GRILLES. 4. REFER TO ELECTRICAL DRAWINGS FOR FIRE ALARM DESIGN AND SPECIFICATIONS. • • 5. • RAISED FLOOR HEIGHT IS 30" IN THE DATA CENTER, AND CEIUNG HEIGHT • IS 12'-0"" ABOVE RAISED FLOOR. 6. SPACE ABOVE THE CEILING IS BEING UTILIZED AS A RETURN AIR PLENUM. RETURN AIR GRILLES TO BE LOCATED OVER ALL HOT •AISLES IN DATA CENTER. 7. CRAC UNITS TO BE DE -ENERGIZED UPON ACTIVATION OF CROSS -ZONE DETECTION OR EPO EVENT.• 8. EXISTING WET SPRINKLER SYSTEM IN NEW DATA CENTER TO BE KEPT IN OPERATION UNTIL SCHEDULED TIME TO RECONNECT TO EXISTING SPRINKLER VALVE AS NOTED ON PLANS, IF REQUIRED BY LOCAL AHJ. COORDINATE SCHEDULING OF SYSTEM TRANSFER WITH BCEI/OWNER. PROVIDE TEMPORARY FIRE WATCH AS NECESSARY DURING SWITCHOVER. KEYED NOTES 0 EXISTING BASE BUILDING WET FIRE SPRINKLER PIPING BRANCH. FIELD VERIFY EXACT LOCATION. • • f-N Q0.3) DEMOLISH ALL EXISTING WET FIRE SPRINKLER MAIN, BRANCHES AND SPRINKLER HEADS BEYOND THIS POINT. CONNECT TO' EXISTING, REDISTRIBUTE TO ALL AREAS • NOTED AS WET SPRINKLER AND REROUTE 4" TO PRE -ACTION PACKAGES IN •SPRINKLER ROOM. 0 • ROUTE NEW 4" WET FIRE SPRINKLER PIPING TO NEW PRE -ACTION PACKAGES IN SPRINKLER ROOM AS SHOWN. 0 ROUTE NEW GALVANIZED PRE -ACTION PIPING TO ASSOCIATED ZONE. PROVIDE • SPRINKLER HEAD LAYOUT, LOCATION, AND TYPE IN COORDINATION WITH CEILING • (IF APPLICABLE). 0 ROUTE 2" PRE -ACTION DRAIN THROUGH EXTERIOR WALL AND TURN DOWN ONTO SPLASH BLOCK. COORDINATE WITH ELECT CONT FOR LOCATION OF CONDUITS AND JUNCTION BOXES. 0 REDISTRIBUTE WET FIRE SPRINKLER PIPING AND HEADS AS REQUIRED BY CODE IN THESE ROOMS. 0 EXTEND NEW WET SPRINKLER PIPING TO SERVE WET SPRINKLER ZONES AS INDICATED BY NOTE 6. . 0 PROVIDE AND INSTALL NITROGEN AUTO -PURGE. • MECH•AN•ICAL LEGEND ••• EXISTING TO REMAIN --x--*--x---x--x--x--x-• EXISTING TO BE DEMOLISHED NEW WET SPRINKLER PIPING NEW PRE -ACTION PIPING -- - - - SEPARATE PERMIT AND APPROVAL REQUIRED Gensler Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 J a) 0 0 0 Cf) 00 cf) 06 C•sj 0'7 1 ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT • RFCFRIFD CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER FIRE SPRINKLER PLAN DRAWN: EPS REVIEWED: GLH PROJECT NO.: C1047.00 SHEET NO. • F2.1 PROPRIETARY: NOT FOR D SCLOSURE OR USE WITHOUT THE WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC. 4, BCE/ SUB-PURLINS EXISTING PURLIN PER PLAN EXISTING BEAM PER PLAN SECURE SLEEPER 'A34' FRAMING PLATES SECURED WITH SIMPSON ik IA Ni if Jr- iiiikWiSki 1 7 Ai BY OTHERS . SECURE NEW CHANNEL TO SIDE OF EXISTING )( X REQ'D. SECTION CONDENSER SUPPORT DETAIL SUPPORT LEG OF NEW CONDENSER PER PLAN • (3) EQ. SPACES • UNIT WIDTH + 6" SLEEPER DETAIL WATERPROOF UNIT ' ANCHORAGE THROUGH CAP FLASHING BY OTHERS NEW SHEET METAL CAP FLASHING BY OTHERS NEW CANT AND ROOFING. PATCH AS REQ'D. BY OTHERS P.T. SLEEPER NEW OR EXISTING FRAMING. VERIFY UNIT ALIGNMENT TO ALLOW PLACEMENT BETWEEN SUPPORT HEADER LOCATIONS FACE MOUNT HANGERS PER PLAN SECURE EACH LEG OF UNIT TO SLEEPER LAG BOLT SECURE UNIT TO SLEEPERS WITH SCREWS EACH LEG. NOTE: VERIFY COMPATIBILITY OF CONNECTION WITH EQUIPMENT " CABINET INTERNALS. CONDENSING UNIT PER PLAN LONG P.T. SLEEPER EACH END OF UNIT SEE DETAIL • 24'-6" / co ro GENERATOR ASSEMBLY BY OTHERS SECURE GENERATOR ASSEMBLY WITH (10) 5/8" 'STRONGBOLT WEDGE ANCHORS BOLT PATTERN EXISTING ON TANK FRAME. VARIES SLAB AND REINFORCING PER PLAN ("6) NEW CONDENSER UNITS WT. = 891 LBS. EACH GENERATOR ANCHORAGE DETAIL X. • CO co EXISTING SKYLIGHT TO BE REMOVED - SEE NOTE #2 FOR INFLL • EXISTING SKYLIGHT TO BE REMOVED -. SEE NOTE #2 FOR !WSJ_ EXISTING 4 X 6 D.F. ROUGH SAWN PURLIN EXISTING EXTERIOR TILT WALL CD • TERMINATE REBAR 3" FROM EACH SIDE OF JOINT. RUN TURN DOWN FOOTING REBAR THROUGH JOINT. (6) FUTURE CONDENSER UNITS WT. = 891 LBS. EACH 6" CONCRETE fc = 2,500 PSI MIN. SLAB WITH #5 AT 24" 0.C. EACH WAY OVER 6" COMPACTED CRUSHED ROCK • co Lcio X 15.5 SECURED TO SIDE OF EXISTING 4 X 14 PURLIN - TYPICAL • • • XI EXISTING SKYLIGHT TO BE REMOVED - PROPOSED FRAMING/EQUIPMENT LAYOUT PLAN 1.) CONTRACTOR TO VERIFY EXISTING CONDITIONS. istOTIFY ENGINEER IF EXISTING CONDITIONS ARE OTHER THAN SHOWN. • • 2.) REMOVE EXISTING SKYLIGHTS S NECESSARY. INFILL HOLES WITH SHEATH WITH 1/2" APA RATED SHEATHING AND NAIL WITH 10d AT ALL PANEL EDGES AND 12" 0.C. IN FIELD. EXISTING SKYLIGHT TO BE REMOVED - • SEE ARCH. FOR FENCE SCREENING • • City of Tukwila BUILDING DIVISION OOKEYPLAN.dwg csi R COMPUTER ENVIRONMENTS, INC. PIP 281-374-8644 Fax 281-074-8992 Two Lincoln Centre 5420 LBJ Freeway, Suite 1100 Dallas, TX 75240 Phone: 214/273-1559 CONSULTING ENGINEERS 3933 SW Kelly Avenue Portland • Oregon 97239-4393 o Lai; 5 ISSUES & REVISIONS No. Date Description 02/17/2014 ISSUE FOR PERMIT RECEIVED CITY OF TUKWILA FEB 2 0 2014 PERMIT CENTER SHEET TITLE HVAC SUPPORT FRAMING PLAN & DTLS. DRAWN: KAN REVIEWED: JCS PROJECT NO.: 20140082 SHEET NO. S1 nO PROPRIETARY: NOT FOR DISCLOSURE OR USE WITHOUT THE 20140081 1—S10—HVAC—Support.dwg 13 Feb 2014 — 4: 57 pm kurtn WRITTEN CONSENT OF BURR COMPUTER ENVIRONMENTS, INC./