Loading...
HomeMy WebLinkAboutPermit M14-0082 - WASHINGTON CENTER FOR PAIN MAN - FAN, DUCTWORK AND GRILLES/DIFFUSERSWASHINGTON CENTER FO 2 PAIN MANAGEMENT 7200 S 180 ST M14-0082 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 3623049013 Permit Number: M14-0082 Address: 7200 S 180 ST 102 Issue Date: 4/22/2014 Permit Expires On: 10/19/2014 Project Name: WASHINGTON CENTER FOR PAIN MAN Owner: Name: KHK INVESTMENT LLC Address: 26329 8TH AVE S , DES MOINES, WA, 98198 Contact Person: Name: ALEX BURKHART Phone: (206) 763-1744 Address: 727 S KENYON ST, SEATTLE, WA, 98108 Contractor: Name: EVERGREEN REFRIGERATION LLC Phone: (206) 763-1744 Address: 727 S KENYON ST, SEATTLE, WA, 98108 License No: EVERGRL954R2 Expiration Date: 1/6/2016 Lender: Name: Address: DESCRIPTION OF WORK: INSTALLATION OF (1) EXHAUST FAN, DUCTWORK, AND GRILLES/DIFFUSERS Valuation of Work: $4,284.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $126.76 Electrical Service Provided by: PUGET SOUND ENERGY Water District: RENTON Sewer Distric: RENTON SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: Date: v ZZH I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: iV1 J Print Name: /'1 13.0-1 h AS This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW Community Developmejnt Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Perrnit No. dU 1I 1+ 001/, Project No. Date Application Accepted: Date Application Expires: 041 N ItH (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION < King Co Assessor's Tax No.: 3(230'f'f013 Site Address: 7260 5 1 $6- S� = Suite Number: l n Floor: Tenant Name: W6k;neyhivl av ` / r Chw New Tenant: ❑ Yes ..No PROPERTY OWNER Name: V t-t k vad-,•,h. ,i__ LLL , Address: 2..G-3 g At,c... S City: boQ AApLoi State: Zip: tigt,t g CONTACT PERSON - person receiving all project communication Name: ►f ,, Address:: -/2-7 5vvA"i1 I yj0-e , City: 5.64, - State: 1„ / Zip: 411,4 Phone: ,-24)& 1(.3_ (- 4 q Fax:.Ibnk,----K.-3- 2-3 Email: a( b & e ,„,,ham.,, ,, MECHANICAL CONTRACTOR INFORMATION Company Name: Y`eLh r1' �lLit tbh Address: -72-7 5 ,, 54_ ' City:0- State: Zip: 4 oxig Phone: -zc 6-`%%3 - 1 r4'4 Fax: v6 -73-- 2.3 8 ci Contr Reg No.: i-av42,612,05q 2ZExp Date: 1 ( G l 14 Tukwila Business License No.: 13US - MZott911 Valuation of project (contractor's bid price): $ 1 Describe the scope of work in detail: ..I-r'$ . -ib" e (�� eadA- -f d,.v-tt-wk-( cam, Use: Residential: New Commercial: New Fuel Type: Electric ❑ Replacement Replacement lekfuse-i5 Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications\ Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being 'installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: (4 ((L! (Li Print Name: A"(-4- 130' Day Telephone: SO ' ' 1C 3 14 Mailing Address: i' 7 50101 ke"`1/`-, St 5 City State Zip H:\Applications\Fortes-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $195.01 EL14-0339 Address: 7200 S 180 ST 102 Apn: 3623049013 $68.25 ELECTRICAL $65.00 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 $65.00 TECHNOLOGY FEE $3.25 TECHNOLOGY FEE R000.322.900.04.00 $3.25 M14-0082 Address: 7200 5180 ST 102 Apn: 3623049013 $126.76 MECHANICAL $121.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $65.00 PLAN CHECK FEE R000.322.102.00.00 $24.38 TECHNOLOGY FEE $4.88 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1789 R000.322.900.04.00 $4.88 $195.01 Date Paid: Monday, April 14, 2014 Paid By: EVERGREEN REFRIGERATION, LLC Pay Method: CHECK 006435 Printed: Monday, April 14, 2014 10:40 AM 1 of 1 11 SYSTEMS INSPECTION RECORD Retain a copy with permit /111 -6O- INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 5outhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: IA .1 • c.< 13 44 - Type of Inspection: ,-. AiMQ cY-i • -1-- ,k) AL, Address: ri-- ..-79.40 4 I Ain - sr - Date Called: Special Instructions: / .) /0, M / Y/ -, Date Wanted: Q `"/4. Requester: -- Phone No: i r7F /10lli .- C07/i-3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: -'rM _ z Q 1 c .to 1 a inspector: Date:jo-i4-14 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION CI 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 iY � f21-v 0 (206) 431-3670 Project: i r� Type of Inspe�C�. v Address; n '72-0 0t , % , �,J ` Date Called: .�. Special Instructions: (0 2._ j Date Wanted: 2 3 ' C---i ` , � .m—. , p.m. Requester: I Phone No: -2 / 1 Approved per applicable codes. Corrections required prior to approval. COMMENTS: V , 1 lam_ o 1,v r • Inspector: A, Date.. - REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MECH-SUM r. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1_and > 3 stojr R2 and R3 Revised June 2013 Project Info FILE vdt•Applicant No.th COPY Project Address 7200 S 180th St. Suite 102 Date 4/14/2014 i Tukwila, WA 98188 For Building Dept. Use Applicant Name: Alex Burkhart Address: 727 SouKenyon St. Seattle, WA 98108 Applicant Phone: 206-763-1744 ext. 247 Project Briefly system Description describe mechanical type and features. Includes Plans Installation of one (1) exhaust fan. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Compliance Option *Simple System O Complex System O Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP/BHP Flow Controls Location of Service 8F-1 Broan QTR110 90 0.2" 0.10 CV Ceiling Service Water Heating Equipment Schedule RECEIVFD tyui ID , ,.r..-VJ �/�� D13r Name, Model No.' Input Capacity Sub- Category EF7 CITY OFIlgwci L� Location of e i CODE COMPLIAN+ APR 1 4 201E APPROVED APR 17 201k PERMIT CENTER - If available. 2 As tested accordin to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. ° COP, HSPF, Combustion Efficiency, or AFUE, as pplicalti}�,77s6li�ai^I es: v iable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer exception number per D BUILDING DIVISION k11c1 wz Mechanical Permit Plans Checklist - Page 1 of 3 MECH-CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 7200 S 180th St. Suite 102 Date 4/14/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance Yes C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 M 1 Yes C403.2.2 Equipment and system sizing Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken M 1 Yes C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical ventilation is capable of being reduced to minimum requirement per IMC M1 Yes C403.2.3 & C403.2.3.2 &efficiency C403.2.12.1 Equipment minimum Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment M1 N/A C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. N/A C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) N/A C403.2.10.3 & C403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. N/A C403.2.3 capacity Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N/A C403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions N/A C403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers N/A C403.2.3 Forced air furnace and unit heaters Indicate intermittent ignition or (ID, flue/draft damper & jacket loss N/A C403.2.3.3 heating/cooling equipment Packaged electric List equipment required to be heat pumps on schedule N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria Yes C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems M 1 Yes C403.2.4.1.1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lock -out temp M1 Yes C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling M1 Yes C403.2.4.3 Automatic setback and shutdown Indicate zone t-stat controls with required automatic setback & manual override M1 Yes C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load conditions M1 Yes C402.4.5.2 & C403.2.4.4 Dampers Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions M 1 Yes C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls M1 N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions N/A C403.2.4.6 Combustion heating equii pment Indicate modulating or staged control N/A C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum N/A C403.2.4.8 / g Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken Yes C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV M 1 Yes C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or alternate means provided to automatically reduce OSA when partially M 1 Yes C403.2.5.3 Enclosed loading dock/parking garage ventilation Indicate enclosed loading dock and enclosed parking garage ventilation system activation and control method M 1 N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method N/A C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or alternative method taken (VAV, semi -conditioned makeup, or GERM calculation) N/A C403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions N/A C403.2.6.2 Energy recovery - condensate systems Indicate on -site steam heating systems requiring energy recovery N/A C403.2.6.3 Energy recovery - condenser systems Indicate remote refrig. condensers requiring ER and use of captured energy Mechanical Permit Plans Checklist - Page 2 of 3 MECH-CHK 2012 Washington State Energy Code Comp fiance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 7200 S 180th St. Suite 102 Date 4/14/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued N/A C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) N/A C403.2.12.1 oo clfcontrol - ling towweers oonq Indicate cooling tower fans requiring variable flow control and method N/A C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and cooling demand; or exception taken N/A C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh N/A C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trendina and demand response setooint adiustment Ducting Systems Yes C403.2.7.1 &Duct C403.2.7.3 construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements M 1 N/A �403.2.7.3.1 ; Duct pressurecation classifications Identify location of low, medium and high pressure ductwork on plans N/A C403.2.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed Yes C403.2.7.1 / 2 Duct insulation Indicate R-value of insulation on ductwork Mi Piping Systems N/A C403.2.8 Piping insulation Indicate R-value of insulation on piping N/A C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SIMPLE SYSTEMS Qualifying Systems Yes C403.3 Qualifying single zone systems Verify unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling M1 N/A C403.3 systems Qualifying 2-pipe heating syst Verify 2-pipe heating -only system does not exceed capacity limits N/A C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 Simple System Economizers Yes C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M 1 Yes C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception M 1 Yes C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table C403.3.1.1.3(2) M 1 Yes C403.1.1.2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh M 1 Yes C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) M 1 COMPLEX SYSTEMS Complex System Economizers Yes C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. M 1 Yes C403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation M 1 Yes C403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems M 1 N/A Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA N/A C403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) Mechanical Permit Plans Checklist - Page 3 of 3 MECH-CHK Group R1, and > 3 story R2 and R3 Revised June 2013 2012 Washington State Energy Code Compliance Forms for Commercial, Project Address 7200 S 180th St. Suite 102 Date 4/14/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS, CONTINUED Specific System Requirements N/A C403.4.2 & C403.2.12 Variable flow control - fans Indicate fans requiring variable flow control and method N/A C403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch N/A C403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure N/A C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken N A / C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A C403.4 Large capacity cooling systems Indicate method of multi -stage or variable control for building cooling system capacity > 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A C403.4.3 systems Large capacity boiler Indicate multi -stage or modulating burner for single boilers > 500,000 btuh N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A C403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use N/A C403.4.2 & C403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control & method N/A C404.2.12.103.4.4 & C403.4.4 control - Varcooling towers flow cooling Indicate cooling tower fans requiring variable flow control and method N/A C403.4.3.4 Hydronic system part load controls Indicate heating & chilled water systems have the capability to automatically reset supply water temp AND reduce flow by >_ 50% for systems > 300,000 N/A C403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range N/A C403.4.3.3.1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat rejection and heat addition modes N/A C403.4.3.3 Water loop heat pump - heat rejection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 N/A C403.4.3.3.3 Water loop heat pump - isolation Indicate 2-way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp N/A C403.4.6 recovery Condenser water heat Indicate system provided to pre -heat service water and efficiency N/A C403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters N/A C403.5 / 6 Cooler / freezer -evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Water Systems N/A C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) N/A C404.3 Temperature controls Indicate temperature controls have required setpoint capability N/A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge N/A C404.5 water Insuheater Indicateunder Indicate R-10 insulation under tank N/A C404.6 Service water piping insulation Indicate R-value of insulation on piping; note exceptions taken N/A C404.7 / g Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand N/A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas N/A C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters >_ 4 COP N/A C404.10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F N/A C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use City of Tukwila Department of Community Development 10/1/2014 Jim Haggerton, Mayor Jack Pace, Director ALEX BURKHART 727 S KENYON ST SEATTLE, WA 98108 RE: Permit No. M14-0082 WASHINGTON CENTER FOR PAIN MAN 7200 S 180 ST Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/19/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/19/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Tha Bill Rambo Permit Technician File No: M14-0082 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 AdO0 ati0O0 11Wa3d PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0082 DATE: 04/14/2014 PROJECT NAME: WA CENTER FOR PAIN MANAGEMENT SITE ADDRESS: 7200 S 180 ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division II Public Works Al4 01;\ Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/15/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 05/13/14 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 EVERGREEN REFRIGERATION T T C Page 1 of 3 411114 Washington State Department of Labor & industries EVERGREEN REFRIGERATION LLC Owner or tradesperson PATTON, RODGER Principals PATTON, RODGER PATTON, MATTHEW Patton, Adam Patton, Douglas EVERGREEN REFRIGERATION LLC PATTON, DAVID (End: 01/21/2014) Doing business as EVERGREEN REFRIGERATION LLC WA UBI No. 602 512 953 727 S KENYON ST SEATTLE, WA98108 206-763-1744 KING County Business type Limited Liability Company Governing persons DAVID A PATTON MATTHEW PATTON; RODGER PATTON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. EVERGRL954R2 Effective — expiration 01/06/2006 — 01/06/2016 Bond Active. Meets current requirements. Merchants Bonding Co (Mutual) $12,000.00 Bond account no. WA15097 Received by L&I Effective date 12/15/2011 01 /01 /2012 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602512953&LIC=EVERGRL954R2&SAW= 04/22/2014 180ih EXHAUST FAN SCHEDULE MARK MANF. MODEL CFM S.P. VOLTS PHASE Hp/A NOTES EF 1 BROAN QTR110 90 0.2" 115 1 71 W LOCATED ON CEILING RESTROOM 128 SF 113 NEW -REST-RO6M 112 60 S NEW STAFF 206 SF 111 250 CFM EXIST JANITOR 48 SF 105 NEW OFFICE 150 SF 124 HVAC FLOOR PLAN SCALE : 1/4" = 1'-0" NEW4 NJECTION 00 109 253 SF COMMISSIONING PLAN ALL COMMISSIONING S ONING OF HEATING VENTILATION AND AIR T CONDITIONING SYSTEMS AS REQUIRED BY N I SECTION C408 'SYSTEM COMMISSIONING' OF THE 2012 WASHINGTON STATE ENERGY CODE (WSEC) SHALL BE PERFORMED BY EVERGREEN REFRIGERATI❑N, LLC. THE ACTIVITIES TO BE ACCOMPLISHED ARE PER THE SECTIONS LISTED IN THE 'C❑MMISSI❑NING COMPLIANCE CHECKLIST' SHOWN BELOW. AT THE COMPLETION OF THE ACTIVITIES REQUIRED FOR COMMISSI❑NING AS DEFINED BY SECTION C408 OF WSEC THE 'COMMISSIONING COMPLIANCE CHECKLIST' WILL BE REVIEWED WITH THE BUILDING OWNER OR THE OWNER'S E S REPRESENTATIVE AND THIS CERTIFICATION WILL BE SIGNED AND DATED. THIS WILL SATISFY TO THE CODE OFFICIAL THAT THE REPORT HAS BEEN ACCEPTED AS REQUIRED BY SECTI❑N C408.1,2.1 OF WSEC, Project Information COMMISSIONING COMPLIANCE CHECKLIST Project Name: Project Address: Commissioning Authority: Commissioning Plan <Section C408,1.1) Commissioning Plan was used during construction and Included Items below • A narrative description of activities and the personnel intended to accomplish each one • Measurable criteria for performance • Functions to be tested Systems Balancing (Section C408,2.2) Systems Balancing has been completed • Air and Hydronlc systems are proportionately balanced ki a manner to first minimize throttling losses • Test ports are provided on each pump for measuring pressure across the pump Functional Testing (Sections C408.2.3) • HVAC Equipment Functional Testing has been completed <Section C408.2.3.1) HVAC equipment has been tested to demonstrate the Installation and operation of components, systems and system -by -system Interfacing relationships in accordance with approved plans and specifications HVAC Controls Functional Testing has been completed (Section C408.2.3.2) HVAC controls have been tested to ens re that control devices are. calibrated, adjusted and operate properly, Sequence of ope atlon hh ve been functionally tested to ensure they operate in act trance wit 1 approved plans and specifications • Economizers Functional Testing has been completed (Section C408.2.3.3) Economizers operate in accordance with manufacturer's specifications Supporting Documents (Section C408.1.3.2) • Manuals, record documents and training have been completed or are scheduled • System documentation has been provided to the owner or scheduled dater • Record documents have been submitted to owner or scheduled dater • Training has been completed or scheduled dater Commissioning Report (Section C408a1.2) Preliminary Commissioning Report submitted to Owner and Includes items below • Deficiencies found during testing required by this section which have not been corrected at the time of report preparation • Deferred tests, which cannot be performed at the time of report preperatlon due to climatic conditions. Certification I hereby certify that all requirements for Commissioning have been completed In accordance with the Washington State Energy Code, including all Items above, Building Owner or Owner's Representative Date 1 NEW HALL II _ 1-L1ISF NEW INJECTION ROOM 200 CFM NEW WAITING / RECOVERY__ 200 SF 300 CFM 107 OPS FROM EXISTING 3 TON FIB.: COPY Permit No, ii01- Plan review approval Is subject to errs and omissions. ,: Ye.1 of construction documents does not authorize !<<c ..nation of any adopted code or ordinance. Receipt of approved Feld Copy and ,1 "I .,r ; ',:,,,,, ed: BY (fj2.1(L City Of Tbicwila BUILDING DIVISION • REVISIONS No changes shall be made to the scope . of work without prior approval of Tukwila Building Division. r T:. •'?'•/;a orls will require a new plan submittal ' may 11,!ude additional plan review fees. i SEPARATE PERMIT REQUIRED FOR: 0 Mechanical iittectrical (Plumbing Watts Piping 'y of Tukwila .'"NtG DIVISION, REVIEWED FOR CODE COMPLIANCE APPROVED APR 17 2014 City of Tukwila BUILDING DIVISION GENERAL NOTES DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND A FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS-7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T-BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 2.2 • INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND. DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T-BAR CEILING AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TO PROVIDE 7-DAY NIGHT SETBACK, PROGRAMMABLE TYPE T-STAT WITH CAPABILITY OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 5.2 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5.3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE AIR INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMATICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC ;SEC. C402.4.5.4 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. C403.4.1 MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2012 SYMBOL LEGEND • SYMBOL , ABBV. DESCRIPTION r DUCT SECTION SUPPLY DUCT SECTION - RETURN/EXHAUST 14'x8' RECTANGULAR DUCT 14' 1 ROUND DUCT `„II ilit \ FLEXIBLE DUCT MVD MANUAL VOLUME DAMPER I I ❑ BDD BDD BACKDRAFT DAMPER T r-i3 MD MOTORIZED DAMPER FD FIRE DAMPER - FSD • FIRE/SMOKE DAMPER (120V POWER REQ.) -®- CEILING RADIATION DAMPER sD SD SMOKE DETECTOR 0 T THERMOSTAT QS S SENSOR R R REFRIGERANT LINES -R G t G NATURAL GAS LINES -G el CEILING DIFFUSER (SUPPLY) CEILING DIFFUSER (RETURN/EXHAUST) D } EXHAUST FAN (CEILING MOUNTED) . of _ INLINE FAN i PROPELLER FAN 1 i l SIDEWALL DIFFUSER DUCT FITTING if ZD ZONE DAMPER UNIT TAG DUCT RISERLA •' M I Do q 2, NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIA TE COMPEN- SATION TO EVERGREEN R EN REFRIGERATION INC. VISU L A CONTACT WITH THE ABOVE AB DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. CO N N Za N SEATTLE, WASHINGTON 98108 727 SOUTH KENYON EVERGRL954R2 DESIGN DEVELOPMENT AS BUILT DRAWINGS HVAC COVER SHEET REVISIONS NO DATE ITEM RECEIVED CiTY OF TUKWILA APR 14 2014 PERMIT CENTER DWG. BY: GN CHK. BY: DP JOB NO.: 413213 SHEET: MI