Loading...
HomeMy WebLinkAboutPermit M14-0148 - BOEING #9-101 - OFFICE AHU UPG - CHILLED WATER SYSTEMBOEING #9-1O1 9725 E MARGINAL WAY S EXPIRED 02/01/2015 M14-0148 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003400018 Permit Number: M14-0148 9725 E MARGINAL WAY S BLDG 9-101 Issue Date: 8/5/2014 Permit Expires On: 2/1/2015 Project Name: BOEING 9-101 OFFICE Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 CONNIE HARDIN 4600 S 134TH PL , SEATTLE, WA, 98168 HOLADAY PARKS, INC. PO BOX 69208 , SEATTLE, WA, 98188 HOLADPI379NO III Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2015 DESCRIPTION OF WORK: REPLACE (5) EXISTING CHILLED WATER AHU'S, DEMO (2) EXISTING AHUS, PROVIDE DUCTWORK & DIFFUSERS. Valuation of Work: $0.00 Type of Work: Fuel type: Fees Collected: $1,987.06 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE,VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: o1 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this developmen '. ; nd agreerto he condii' ns attached to this permit. Signature: Print Name: �) (� A e is Date: 0 —�� ( Y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Readily accessible access to roof mounted equipment is required. 2: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 3: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 17: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 11: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 15: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 16: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 10: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST • CITY OF KWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov S f� Mechanical Permit Na . ... Project No: Date Application Accepted { 7h .V Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION ' Site Addres . Tenant Name (AC' — 3 c e4 A40 ! �,QS PROPERTY OWNER Na 1 h..� i:50e.t •Clipact.....4.6. ess: t M' City: e. state!Z,yp� Z� �3 CONTACT PERSON —;person receiving all project communication ng Co Assessor's Tax No.:00 gCbD / a Floor: Suite Number: New Tenant: ❑ Yes EinCio MECHANICAL=CONTRACTOR INFORMATION Company Name d � h T i�� pa4n Addres,�: / (ono s 4..,,, pit A City' 1 n Q State �_ Zipas/ (ins Phon�:��G�0t `�? Fax:2a,z 1g g 70 L•r x,�J.-xi Contr Reg NQ�: _ IlJ(j yer Date: ci_an!� Tukwila Business License No.: Valuation of project (contractor's bid price): $ I IP 000(9•12...•"%-ito CZ R-Os Describe the sco s of work in detail: i Use: Fuel Type: Residential: New ❑ Replacement Commercial: New ❑ Replacement Electric ❑ Gas ❑ Other: dittilktO -c-1-1 H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty :. Furnace <100k btu Furnace >l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unitLi <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler ` Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN ENT: Signature: Print Name: 0,A At C [l-rA l� Mailing Address: tko O( S Day Telephone: .An City Date: 20 2.gr6 o?' State Zip H:Wpplications'Forns-Application 0n Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 DESCRIPTIONS PermitTRAK�' Cash Register Receipt City of Tukwila ACCOUNT QUANTITY PAID 4 01r ressi'9725 E MARGINA S: BLDG 9 m 00034000 l7 MECHANICAL $1,91063 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $1,496.00 PLAN CHECK FEE R000.322.102.00.00 0.00 $382.13 TECHNOLOGY _ 7643 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R2645 R000.322.900.04.00 0.00 $76.43 $1,987.06 Date Paid: Tuesday, July 22, 2014 Paid By: HOLADAY PARKS FAB INC Pay Method: CREDIT CARD 07623G Printed: Tuesday, July 22, 2014 10:53 AM 1 of 1 CRWYSTEMS INSPECTION RECORD Retain acopy with permit INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT- 206-575-4407 Project: v Co . Type of Inspection: LAA.co,ti . Address: 5- 5'' .yy Suite#: 9—io1 S Contact Person: Special Instructions: Phone No.: L71,Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: , Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /A.\ --a-- Date: . /ay/l S Hrs.: <9....__ $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Address: Company Name: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 FILE COPY KIA CO 163'01 N.E. 6th St:, Ste 251 Bellevue, WA 96606 Phone 425.644.6,400 Ceti 425.351.5g99 BOEING 9-101 9725 EAST MARGINAL WAY SOUTH SEATTLE, WASHINGTON 98108 AHU-57, AHU-58, AH-61, AH-62 & AH-2-F16A ATTACHMENT SUPPORT FOR HOLADAY-PARKS, INC. STRUCTURAL CALCULATIONS J U LY 20, 2014 JOB NO: 124-1407 CODE FOR ODE COMPLIANCE APPROVED AUG 05 2014 City of Tu BUILDING Dlkwila VISION RECEIVED CITY OF TUKWILA JUL 2 2 2014 PER ITC N NOTES' PARTIAL: FLOOR PLAN 1) CONTRACTOR TO VERIFY ALL SIZES, DIMENSIO.NS,,AND LOCK -IONS MELD. a CONTRACTOR.TO. VERIFY :MECHANICAL .UNIT SIZE, WEIGHT AND LOCATION. Froiecusubiec t .4= Shea( No/4-- Date Job rrN��o, 0 u Pr jecVSub ea 9y Sheet No. L 1 Date s Job No. Wir ProtecVSubleci • By ,Sheet N�o. j Date :Job No: .... ... ...... . . . . . . c^f • J. eitt:7 .•••••••• Projact/Subiect By Stteet Nt),42 Date (13 4-77, 1 o . 4- .4-> y ,-t // Project/Subject By Sheet No, Date Job No. 1 ... PrqactiStappact 47- By Date S4teet INV4te:5 Job No. Z. ,9G . . .... .... • 0 Project/Subject • ) By Sheet N4</..i.c:5, 9 7 * - Lj .1 Date Job No ) MCE Ground Motion - Conterminous 48 States Zip Code - 98108 Central Latitude = 47.54683 Central Longitude =-122.308312 Period MCE Sa (sec) (%g) 0.2 151.3 MCE Value of Ss, Site Class B 1.0 052.4 MCE Value of S1, Site Class B Spectral Parameters for Site Class D 0.2 151.3 Sa =FaSs, Fa = 1.00 Fv = 1.50 1.0 Spectrum Period (sec) 0.000 0.104 0.200 0.519 0.600 0.700 0.800 0.900 1.000 1.100 1.200 1.300 1.400 1.500 1.600 1.700 1.800 1.900 2.000 078.6 . Sa = FvS1, for Site Class D MCE Sa (%g) 060.5 151.3 151.3 151.3 131.0 112.3 098.2 087.3 078.6 071.4 065.5 060.5 056.1 052.4 049.1 046.2 043.7 041.4 039.3 T = 0.0, Sa = 0.4FaSs T = To, Sa = FaSs T = 0.2, Sa = FaSs T = Ts, Sa = FaSs T = 1.0, Sa = FvS1 SEISMIC (2012IBC � (AHU-57) ZIF CODE 98108 LATITUDE. 47.54 LONGGTUDE -.1122.31 1. 513 9 S1 = 0. 524 9 SITE CLASS "D' SDC= D Fa = 1 Fv = 1.5 ms= FaxSs= 1.. 13 -g Sm1 =FvxS1 = 0.79 Sds = 2/3 Sms 1 .01 g Sd1 = 2/3 Sm1 = 0.52 _g Fp = (0.4 Ap.Sds.Wp/(Rp/ip)) / (1 + 2 ZJH) (EQ. 13.3-1) Ap = 2:5 Ip Rp= Sds 6 Project/Subject By , • } c1 Date ZJH =- 0.67 (17.7/26.7 Wp = 4735 Ibs Fp 1,863 Fbs Fp (MAX) 16 Sds..lp Wp =. • 7;642 lbs > Fp 0 Fp (MIN) = 0.3 Sds.lp.Wp = 1,433 lbs < Fp 0 K. K. • • ......... (SEISM C GOVERNS IN BOTH DIRECTIONS) CHECK UNiT STABILITY: SHORT DIRECTION: F(Seis.) = 1,863. lbs M (O. .) = 3 25 lbs-ft M(R) = 10251 lbs-ft 0 9 M R)= 9226 lbs-ft M 0.T.) NO UPLIFT ... ......... iect/Subiect By t'R Sheet 11 y,./.ey i Date Job No ),04*'7) SEISMIC 20 2 IBC) (AHU-58) ZIP CODE: 9 108 LAT TUDE = 47.54 LONGITUDE = 122.31 Ss 1,513 g Si = 0.524 g SITE CLASS $DC = D Fa = 1 Fv = 1 5 Sms = Fa x Ss = Sm1 = Fv S1 — 1.513 g 0 79 g Sds = 2/3 Srns = 1 01 g ......... .... .......... Sd1 = 2/3 Sm1 = 0.52 g ..... . • • .• Fp = (0.4 Ap.Sds.Wp/(Rp/Ip)) Ap = Ip — 2.5 1 (1 Z/H) (EQ. 13.3-1) Rp 6 Sds 1.01 ...... ...... Project/Subj /•;e11,-;W By Sheet N. • -t. Date ,Job 4f;'" ). •1:71 Z/H 0.67 c17.7126:7) Wp 5270 Ibs Fp.= ........2,073 lbs Fp WAX) - 1.6 Sds,lp Wp 8,505 lbs > Fp (MIN) 0.3 Sds.Ip.Wp = Fp...O 1,595 lbs < Fp 0 K. (SEISMIC GOVERNS IN BOTH DIRECTIONS) CHECK- UNIT STABILITY: SHORT DIRECTION: F(Seis.) = 2 073 y (O.T.)= 4146 lbs IbS-ft M(R) 14045 lbs-ft 0.9 M (R)= 12640 lbs ft >M (O.T.) NO UPLIFT ProjectVSubject " By /7 , Date 11, • o, ................. Oct/Subject Sheet No. Date 7 Job No. SEISMIC 2012 IBC AH=2-F16A) ZIP CODE: 98108 LATITUDE _ 47.54 LONG.ITUD.E = 122.31 Ss= 1:.51•3 9 S1 0.524 9 SITE CLASS SDC.= D Fa = 1 Fv = 1.5 Sms.= Fa is Ss = Sm1 =FVxS1 1.513 g 0:799 Sds = 2/3 Sms = 1:01 g Sd1 = 2/3 Sm1 = 0.52 g Fp = (0.4 Ap.Sds.Wp/(Rp/Ip)) / (1 + ZJH) Ap 2.5 Ip= Rp 1 (EQ. 13.3-1) 6 Sds 1.01 Project/Subject By ZJH'_ 0.67 (17:7/26.7) Wp 2047 ibs p- 805 Ibs' Fp (MAX) — 1.6 Sds.Ip:Wp = 3,304 lbs > Fp O.K. p (MIN) 0.3 Sds.ip .Wp = 619 Ibs < Fp 0 K. (SEISMIC GOVERNS IN BOTH DIRECTIONS) CHECK. UNIT STABILITY: SHORT DIRE CTION: F(Seis.) = 805 M(O.T.) 1409 Ibs • Ibs-ft M(R) 3071 Ibs-ft 0.9M(R) 2763 ibs-ft > M (O..T..). . NO UPLIFT ................... Project/Subject Sy Sheet No. © 7- Job No. SEISMIC (2012IBC) (AH-61, 62) ZIP CODE: 98105 LATITUDE 47.54 LONGITUDE _ -12 .31 Ss 1.513 .g S1 = 0 524 0 SITE CLASS SDC. =.R Fa 1 Fv = 1.5 Sms = Fa x Ss = 1.513 g m1 =FvxSi = :79.g Sds = 2/3 Srns 1.01 g Sd1 = 2/3 S m1 = 0.52 g -Fp = (0.4 Ap.Sds Wp/(Rp/Ip)) / (1 + 2 ZJH) Ap = Ip = 2.5 1 Rp= 6 Sds ........1.0.1 (EQ. 13 3-1) ect/Subj , By ShsettNo� l7 D Date Job No: Z/H 0.67 •(17.7726-7') Wp 2048 Ibs Fp 806H bs Fp (MAX) 1.6-Sds:Ip Wp 3,305 lbs > Fp O. K. Fp (MIN) = 0.3 Sds.Ip,Wp = 620 Ibs < Fp O K. (SEISMIC GOVERNS IN BOTH DIR EC IONS) CHECK UNIT -STABILITY. SHORT DIRECTION: F(Seis.) = 806 Ibs M (O.T.) _ 1611 lbs-ft M(R) _ 3072 Ibs ft 0 9M (R)= 2765 Ibs-ft M (O.T.) NO UPLIFT Project/Subject By Date , ),7 Pro,eoVSubjea Date Job No. ' fT 1"--JAY 9 APPENDIX I FRONT_ENIIVIEW Product Drawing Product: Vision Air Handler Model: CAH030GDDM 136 O.D. BASE Unit Tag: AHU-57 at 5000cfm Project Name: Boeing 9-101 Mar 26, 2014 ; Ver/Rev: PLAN VIEW ISOMETRIC VIEW ELEVATION VIEW _ _ REAR i:,ND VIEW Sheet 1 of 1 Sales Office: Sales Engineer: Scale: NTS i Tolerance: a/ 0.2S" Dwg Units: in 13600Industrial Park Blvd, Minneapolis, MN 55441 www.DaikinApplied.com Software Version: 1011 Product Drawing Product: Vision Air Handler PLAN VIEW ELEVATION VIEW Unit Tag: AHU-57 at 5000cfni Project Name: Boeing 9-101 Sales Office: Sales Engineer: Model: CAH030GDDM i Mar. 25, 2014 ! Ver/Rev: Sheet: 1 of 1 Scale: NTS Tolerance: s-/-0.2S" Dwg Units: in Component Key Vhxing Box !J ilter Type: AmAir 1300 ight Door Width: 26 ins oEWater Coil B ' oil Model: 5WH1001C otal Capacity: 224724 Btu/hr ight Door Width: 12 ins hilted Water coil , oil Model: 5WM0806B otal Capacity: 185553 Btu/hr ight Door Width: 14 ins �p) ccess5e[fion an an Type: Centrifugal - Plenum an Size (Class): 20 (2) © 4ir Flowrate: 5000 cfm .S.P: 1.69 insWg otor Power: 5 HP tight Door Width: 20 ins Base 6" deep, Cross members extend 4" on each side of the unit. iN 13600 Industrial Park Blvd, Minneapolis, MN 55441 www.DaikinApplied.com Software Version: 10.11 Unit Connections Product: Vision Air Handler Model: CAH030GDOM LEFT ELEVATION VIEW 69.35 46.57 . .....L -4 14: ,4 rc - "•--. -,.. ..---- ---' ,..----' ,-- .-- ,- -- ---., ---. ---. --. r '-''''—• ''''' .7.,,,,,iet"tiL, !t7.:17' '''''' 1-- 46 57 74 48 RIGHT Fl EVATIQN VIEW Unit Tag: AHU-57 at 5000cfm I Sales Office: Project Name: Boeing 9-101 Sales Engineer: Mar 26, 2014 Ver/Rev: Sheet: 1 of 1 Scale, NTS Tolerance:4/0,25 Dwg Units: in rafl IKIIV 13600 Industrial Park Blvd, Minneapolis, MN 55441 www.DaikinAppliettcom Software Version- 10.11 VisionTM Air Handling Unit 'AMIN Shippitfg:5e Section 1 2 3 4 Entire Unit YY Length in 42 22 30 52 146 Weight ib'' P 935 234 810 207 1497 386 461 1271 ► XX Corner:Weights (lb) P2 P3 234 234 198 363 243 984 PQ 234 198 207 363 386 272 516 1083 1398 Plan View NOTE: Special components aren't included in the corner weights and center of gravity data. Center of Gravity (in) YY 21 61 11 60 15 62 27 42 76 53 27 27 27 24 26 AffR I, ication Supply fan performance is certified in accordance with the Central Station Air -Handling Unit Certification Program, which is based on AHR1 Standard 430. Notes Standard 1. As a standalone component, unit meets or exceeds requirements of ASHRAE 90.1- 2007. The approving authority is responsible for compliance of multi -component building systems. Page 5 of 5 www.Daiki Anpiied,com woo•pagaavupt!ea•mmm :ana pandaid _ 0 RUND_VIEW Product Drawing Product: Vision Air Handler od- el CAH030GDBM PLAN VIEW 162 Dampr 26 Unit Tag: AHU-58 Sales Office: Project Name: Boeing 9-101 Sales Engtneer: Mar. 14, 2014 I Ver/Rev. Sheet. 1 of 1 HiS I Tolerance: +/-0 25" 0,,Aeg Up11s: 411 ISOMETRIC VIEW REA&NDY1E,W._.... VPDASIelltit 13600 Industrial Park Blvd, Minneapolis, MN 55441 www.DaiivnApplied.com Software Version: 10.11 ss-nEiv .101 2ulmegi :duaeN qOr LUVb du!dua :.aguanN gar X z :a;ed paaedaJd Product Drawing Product: Vision Air Handler Model: CAH030GOBM rAl s lit 46 PLAN VIEW (6) Qc stilt 22 split 30 38 64 6 �. 20 LE AILON1.}LtEW Unit Tag: AHU-58 Project Name: Boeing 9-101 Mar 1472014 1 Ver/Rev .i Sheet: 1 of 1 Sales Office: Sales Engineer: Scale. NTS [elerance.</-0.25" Dwg Units: in Component Key txrng Box (A) ilterType: AmAir 1300 eft Door Width:- 26ins of ater (oil B oil Model: 5WH1001C Total Capacity: 633897 Btu/hr eft Door Width: 12 ins ilia Water coif) oil Model: SWM0806B otal Capacity: 545410 Btu/hr eft Door Width: 14 ins -an an Type: Centrifugal - Twin an Size (Class): 15 (1} ar it Flowrate: 17000 cfm .S.P: 3.87 insWg otor Power: 30 HP eft Door Width: 30 ins Base 6" deep, Cross members extend 4" on each side of the unit. 13600 Industrial Park Blvd, Minneapolis, MN 55441 www.DaikinApplied.com Software Version: 10.11 SS-f1Hd aoj 2u!Meaa O X 23 ) Z '--I D :alea paiedaid 3 5 3 • oj 3• NJ S '0 3 Is. ill 13 85.65 ,-- '&!---,/*,•!=.5 ......_ ,--,----- ..., ...-":„." -„----iii--- -- .,:.: '--, .. ' -,--,--, ,•,--•,:',W,1 • ,,, , ir,,,,..,_.iti ,__ .S3.51 111.43 Unit Connections Product: Vision Air Handler LEFT ELEVATION VIEW RIGHT FLEVATION3LIEW Unit Tag: AHU-58 Project Name: Boeing 9-101 Model CA1-4030GDBM Sales Office: Sales Engineer: Mar. 14,2014 I Ver/Rev. [Sheet. loll kale: NTS : Tolerance: 4-/-0.25" Dwg Units. in 13600 Industrial Park Blvd, Minneapolis, MN 55441 www.DaikmApplied.com Software Version 10.11 iis-nHv Joj. 2uInxeJa VisionTM Air Handling Unit AMIN t Type Radiated: Unit Discharge: Unit Return: 3 ippin.€ 63 Hz 83 91 89 length in 44 2 22 3 30 4 58 Entire Unit 154 YY 125Hz 85 93 91 Weight lb 992 810 1415 2053 250 Hz 81 93 90 P1 248 207 365 522. 1249 XX 500 Hz 74 91 87 Corner Weights (II)) "P2 rP3 248 248 198 342 465 1164 198 342 502 1378 Plan View NOTE: Special components aren't included in the corner weights and center of gravity data. 1000 Hz 2000 Hz 69 89 84 P4 248 207 365 564 1478 62 85 80 xx• 22 11 15 30 83 4000 Hz 8000 Hz 50 44 85 80 78 79 Center of Gravity (in) 61 27 60 59 57 59 27 27 24 26 Page 4 of 4 ww w.DaikinAoolind.com Product Drawing Product: Vision Air Handler PLAN VIEW Unit Tag: AH-2 -F16A Sales Office: Project Name: Boeing 9-101 Sales Engineer: 13600 Industrial Park 81vd, Minneapolis, MN 55441 Mar 14. 2014 1 Ver'Rev • — 1 Sheet 1 of 1 Scale: NTS Tolerance:+/,0 25" f Din Units: in , • www DaikinApplied cam Software Version: 1011 ISOMETRIC VIEW ww,affkia ELEVATIONSIEW ____REAR_ENDAdEW DAIKIN Z-HV Jol 2u!nne.ig :a;ea paaedaad w N B N ,-1 106 PLAN VIEW 106 Product Drawing Product: Vision Air Handler Model: CAH012G©AC .._EtEVATIQN VIEW Unit Tag: AH-2 -F16A Component Key hung Box �ilter Type: AmAir 1300 ight Door Width: 20 ins ott a ter Coil ® iCoil Model: SWHO702B Total Capacity: 201069 Btu/hr :hille. Water coil Coil Model: SWHO906B Total Capacity: 190135 Btu/hr -an 'an Type: an Size (Class): it Flowrate: ,S.P: otor Power: ight Door Width: Centrifugal DWDI 16 (2) 5000 cfm 3.34 insWg 5 HP 30 ins Base 6" deep, Cross members extend 4" on each side of the unit. Project Name: Boeing 9-101 Mar. 14, 2014 yen/Rev: j Sheet: Y of 1 Sales Office: Sales Engineer: Scale: NfS 1'tolerance: 4/-0.2S" Dwg Units: in www.DaikinApplied.com Software Version: 1011 drIAIKIN 13600 industrial Park Blvd, Minneapolis, MN 55441 V9tJ- Z-HV ao} 5uimeaa :a4ea paaedaid Unit Connections Product: Vision Air Handler Model: CAHO12GDAC Unit Tag: AH-2 -F16A [Project Name: Boeing 9-101 Mar. 14, 2014 Ver/Rev: LEFT ELEVATION VIEW RIGHTELEVAT14P1 VIEW Sales Office: Sales Engineer Sheet: 1 of 1 Scale. NTS Tolerance: +;-0.25" LDwg Units. in DAA1( IN 13600 lndustria! Park Blvd, Minneapolis, MN 55441 www Daik nApplied corn Software Version: 1011 V9ZU- Z-HV 2u!Meaa Technical Data Sheet for AH-2 -F16A ect rti-Det Section Length in. 24 2 36 3 46 Entire Unit 106 YY Weight lb 376 879 792 P1 94 211 220 546 XX Corner Weights (lb) P2 P3 94 94 189 227 172 176 474 477 Plan View NOTE: Special components aren't included in the corner weights and center of gravity data. Notes Center of Gravity (in) P4 XX VY ZZ 94 12 33 24 253 20 31 24 225 23 29 21 550 53 31 23 Supply fan performance is certified in accordance with the Central Station Air -Handling Unit Certification Program, which is based on AHRI Standard 430. Standard 1. As a standalone component, unit meets or exceeds requirements of ASHRAE 90.1- 2007. The approving authority is responsible for compliance of multi -component building systems. Job Number: XNR774 Page Prepared Date: 3/14/2014 Job Name: Boeing 9-101 30 of 59 www.DaikinApplied.com :alea panciam FRoNT END VIEW _ Product Drawing Product: Visign Air Handler Model. CAHM.1GDAC 74 O.D. BASE PLAN VIEW EJ.EVATIO VIEW Unit Tag: AH-61 Safes Office: _ . Project Name: Boeing 9-101 Sales Engineer: Mar 14 2014 VerRev- Stieet1 of 1 Scale: WS Tolerance: 4/-0 25" Dwg Units: in ISOMETRIC VIEW _REAB. DNIEW . VI' IKIIV 13600 Industrial Park Blvd, Minneapolis, MN 55441 www DaikinApplied.com Software Version- 1011 I 9-HV 2upvteJ0 7 O S O' Z Z U c 3 3 v t] • re -s x z J LUL-b auivua u 0 3 v .n :a4ea paiedaLd ci 0 Product Drawing Prcu uct: Vision Air Handler Model CAH012GDAC 24 36 PLAN VIEW 38 6 46 ELEY_ATL9fLVtEW. Unit Tag: AH-61 1 Project Name: Boeing 9-101 Mar. 14, 2014 VerJP.ev l Sheet 1 of ] Sales Office: Sales Engineer: Scale: NTS 11 Tolerance; +J-0 25" Dwg Units: a Component Key wing Sox -liter Type: AmAir 1300 eft Door Width: 20 ins 01 W terCot oil Model: SWHO702B Total Capacity: 201069 Btu/hr pilled Water coil oil Model: 5WHO906B Total Capacity: 190135 Btu/hr an an Type: Centrifugal DWDI an Size (Class): 16(2) it Flowrate: 5000 cfm .S.P: 3.34 insWg Motor Power: S HP Left Door Width: 30 ins Base 6" deep, Cross members extend 4" on each side of the unit. 13600 Industrial Park Bled, Minneapolis, MN 5S441 www.DaikinApp!iedcorn Software Version: 10.11 I9-Hd ao} SutMeaa LU L-b 43uioua _u -n u+LLI fJo1.1UUVUIPieu JVFVV X Z P :area paaedaad Unit Connections 77,43 613 I. 'A 84 66 7743 Unit Tag: AH-61 LEFT ELEVATION VIEW RIGHT El EYATION VIEW Product: Vision Air Handler Model CAH012GDAC Project Name: Boeing 9-101 Mar. 14, 2014 I Ver/Dev: Sales Office: Sales Engineer Sheet: 1 of 1 Scale: NTS Tolerance:+/-0.25" Dw6 Units: in /.IN 13600 Industrial Park Blvd, Minneapolis, MN 55441 www.vaik nAppiled.com Software Version: 10.11 Z9-HV JO SupAeaq Technical Data Sheet for AH-61 Section i'{T3tati Length in 24 2 36 3 46 7 Entire Unit 106 YY Weight Ib. 376 879 P1 94 211 220 546 XX Corner Weights (lb) P2 P3 94 94 189 227 172 176 474 477 Plan View NOTE: Special components aren't included in the corner weights and center of gravity data. Center of Gravity (in) P4 XX YY ZZ 94 12 33 24 253 20 31 24 225 23 29 21 550 53 31 23 104RJC fica'tion Supply fan performance is certified in accordance with the Central Station Air=Handli.ng.Unit Certification Program, which is based on AHRI Standard 430. Notes Standard 1. As a standalone component, unit meets or exceeds requirements of ASHRAE 90.1 - 2007. The approving authority is responsible for compliance of multi -component building systems. Job Number: XNR774 Job Name: Boeing 9-101 Page Prepared Date: 39 of 59 3/14/2014 \AMA/\AI rinilrinAnnlinr! rn.,, FRONT END VIEW Product Drawing Product: Vision Air Handler rvtoael: CAH012GDAC 74 OD, BASE 24 PLAN VIEW 36 (D) 38 46 6 ELEVATIOV /IEVV_ Unit Tag: AH-62 reduced to 5k cfm Sales Office: Project Name: Boeing 9-101 Sales Engineer: I Mar 26, 2014 I Ver) Rev 1 Sheet: 1 of 1 Scale. NTS Tolerance: 4/-0.25" ISOMETRIC VIEW 13600 Industrial Park Blvd, Minneapolis, MN S5441 Dwg Units in wvw.DaikinApplied.con, Software Version: 10.11 74 0. D. BASF 24 Product Drawing Product: Vision Air Handler Model: CAH012GDAC PLAN VIEW 106 ELEVATIOILVIEW Unit Tag: AH-62 reduced to 5k cfm , Sales ffce: Project Name: Boeing 9-101 'Sales Engineer: Scale: NTS 1 Tolerance: 4/-0.25" Mar. 26, 2014 Ver/Rev I Sheet 1 of 1 Dwg Units: in Component Key rxmg tsox liter Type: fight Door Width: of Water Coil ® toil Model: Total Capacity: ChillerTVater coil ) Coil Model: Total Capacity: "a n :an Type: fan Size (Class): Air Flowrate: T.S.P: Motor Power: fight Door Width: CD? AmAir 1300 20 ins 5WH0702B 203886 Btu/hr 5WH0906B 190293 Btu/hr Centrifugal DWOI 16 (2) 5000 cfm 3.34 insWg 5HP 30 ins Base 6" deep, Cross members extend 4" on each side of the unit. 13600 Industrial Park Blvd, Minneapolis, MN 55441 www DaikinApphedcom Software Version. 10.11 Unit Connections Product: Vision Air Handler Model: C.AH012GDAC LEFT ELEVATION VIEW Unit Tag: AH-62 reduced to 5k cfm Project Name: Boeing 9-101 TI0L[VIEW Sales Office: Sales Engineer: Mar 26: 2014 Vert Rev Sheet: 1 of 1 Scale. NTS I Tolerance: v/-0.25` Owe Units: in F 13600 Industrial Park Blvd, Minneapolis, MN 55441 www DaikinApplied.com Software Version. 10.11 Vision'" Air Handling Unit [ppink tioii etaiis... Entire Unit YY length in 24 36 46 106 Weight lb XX Corner Weights (lb) P2 P3 9494 189 227 172 176 474 .477 Plan View TOTE:Specidi components aren't included in the corner weights.and center' of gravity data. AHRI,Ceitirim? ion Supply fan performance' is certified in accordance with the Central Station Air -Handling Unit Certification Program, which is based on AHRi~Standard 430. Standard `s 1. As a standalone component, unit meets or exceeds requirements ofASHRAE 90.1 - 2007. The approving authority is responsible for compliance of multi -component building systems. Page 4 of 4 i'JbVb'1.13af.1nKQzThe'Q C413"s City of Tukwila Department of Community Development 1/5/2015 CONNIE HARDIN 4600 S 134TH PL SEATTLE, WA 98168 RE: Permit No. M14-0148 BOEING 9-101 OFFICE 9725 E MARGINAL WAY S Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/1/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/1/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, fermi r Marshall ermi Technician Fi1e"Ng M14-0148 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0148 DATE: 07/22/2014 PROJECT NAME: BOEING #9-101, AHU UPGRADES SITE ADDRESS: 9725 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: A-7 iltdc 01.1141 Building Division Public Works n Fire Prevention ® Planning Division Structural n Permit Coordinator n PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 07/24/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 08/21/14 Approved with Conditions �(�, Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Page 1 of 4 0 Washington Mate Deparintent of Labor & Industries HOLADAY PARKS INC Owner or tradesperson PARKS, GERALD T JR Principals PARKS, GERALD T JR, PRESIDENT NAILON, JUNE ANNETTE, VICE PRESIDENT O'CONNOR, BONNY K, SECRETARY BECK, DAVID CLARENCE, TREASURER VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. HOLADPI379NO Effective — expiration 01 /21 /1983— 09/03/2015 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452 $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance Old Republic General Insurance $1,000,000.00 Policy no. Al CG96431203 Received by L&I Effective date 10/31/2013 11 /01 /2013 Expiration date 11/01/2014 Insurance history https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 08/05/2014