HomeMy WebLinkAboutPermit M14-0219 - RPI - ROOFTOP UNITRPI
3325 S 116 ST
M14-0219
Parcel No:
Address:
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206:431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
0923049068 Permit Number:
3325 S 116TH ST 101 Issue Date:
Permit Expires On:
Project Name: RPI
M 14-0219
12/24/2014
6/22/2015
Owner:
Name:
Address:
Contact Person:
Name:
Address:
EPROPERTY TAX INC DEPT 207
PO BOX 4900 , SCOTTSDALE, WA,
85261
JESSE CHUTICH
3202 C STREET NE , AUBURN, WA,
98002
Contractor:
Name: COMFORT MECHANICAL INC
Address: 3202 C ST NE , AUBURN, WA, 98002
License No: COMFOM1015LA
Lender:
Name:
Address:
Phone: (425) 251-9840
Phone: (425) 251-9840
Expiration Date:
DESCRIPTION OF WORK:
REPLACE (1) 6-TON GAS PACKAGED ROOFTOP UNIT WITH NEW 6-TON TO ROOFTOP UNIT
Valuation of Work: $6,673.00
Type of Work: REPLACEMENT
Fuel type: GAS
Fees Collected: $285.10
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer District: VALLEY VIEW SEWER SERVICE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
International Fuel Gas Code:
2012
2012
2012
2012
2012
National Electrical Code:
WA Cities Electrical Code:
WAC 296-46B:
WA State Energy Code:
2014
2014
2014
2012
Permit Center Authorized ._,AAMAAcjAW. UV \cjA Date: l2-
z
(4
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name: V.-SS / c,
Date: / 24/
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***MECHANICAL PERMIT CONDITIONS***
2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
3: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
4: Manufacturers installation instructions shall be available on the job site at the time of inspection.
5: Equipment and appliances having an ignition source and located in hazardous locations and public garages,
PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be
elevated such that the source of ignition is not less than 18 inches above the floor surface on which the
equipment or appliance rests.
6: Readily accessible access to roof mounted equipment is required.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
11: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance
#2437)
12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings
shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the
power source of the air -moving equipment upon detection of smoke in the main return -air duct served by
such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall
be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1)
13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437)
14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City
Ordinance #2437)
15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437)
16: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2437) (IFC 901.2)
17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances
#2436 and #2437)
19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400 FIRE FINAL
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
0702 SMOKE DETECTOR TEST
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA,gov
Mechanical Permit No. '- -4;)0
Project No.
Date Application Accepted: 12 t
14
Date Application Expires: (0
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
Site Address:
King Co Assessor's Tax No.: 0 `f 2 30 q -'to c g
Tenant Name: R FL
Suite Number: 'o 1 Floor: re'
PROPERTY OWNER .
Name: L- 1 ro0er f7
Address: 3 3•1r S "4 +A
S �g7�
City: �,,,,,.1 11 State: a Zip: 47/8/
CONTACT PERSON - person receiving all project:
communication
Name: VCo.SSe. G4 .4. ; cx
Address: 3 2 o. c .4.. T_ Jo
City: Arot ern State:j _ w,,4
Zip: e(3002
Phone: q Zs. - z St - d QyoFax:
Email: `(e cSe (f GOtwrori'nle
•Ger'+
New Tenant: D Yes 12r..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: / �
�'J O f oinPr✓A do i,Gaei
Address: 's'LG Z C S- N p
City: /"'�'1 r krR State:'„ /'/1 Zip4d0O1
`� v J 1' O
Phone: ft Z.. S' 2 S—( "t f (�QFax:
Contr Reg No.: / ,*., t A j�T-01� pate: cvz4.- ( G
A, Y
Tukwila Business(LicenseicNo.o.:QGr G
3 S`
Valuation of project (contractor's bid price): $ 6,6 73
Describe the scope of work in detail:
Re'l die, 0) -
s,_S r6G/Ca fn l roof4 r 4tr1; f w►�4 new
Use: Residential: New ❑
Commercial: New
CI
Fuel Type: Electric ❑ Gas
Replacement
Replacement
❑
Other:
H:\Applications\}onns-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-I l.docx
Revised: August 2011
bh
�i-fo,, of4-413
Page I of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
f
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfin
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
tr•S ?gag le.
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR AUTHORIZED AGENT:
Signature:
Print Name:
Mailing Address: 3 Z 0 Z G$ A/ F
H:'Appl icat ions\Forms-AppRom ions On Line1201 I Applications \Mechanical Permit Application Revised 8-9-I I.docx
Revised: August 201 I
Rh
Day Telephone:
A
City
Date: )
to .5- -Zs - €?'$ro
VA agooZ
State Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK ��
ACCOUNT QUANTITY
r �:�
PAID
vz
$285i10
M14-0219 Address: 3325 S 116TH ST
Apn: 0923049068
` $285 10
MECHANICAL
$274.13 ;.
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$186.80
PLAN CHECK FEE
R000.322.102.00.00
0.00
$54.83
TECHNOLOGY FEE
$10.97
TECHNOLOGY FEE
TOTAL FEES PAID BY RECEIPT: R3735
R000.322.900.04.00
0.00
$10.97
$2.85.10
Date Paid: Wednesday, December 10, 2014
Paid By: JESSE CHUTICH COMFORT MECHANIC
Pay Method: CREDIT CARD 010182
Printed: Wednesday, December 10, 2014 8:28 AM 1 of 1
CRSYSTEMS
INSPECTION RECORD
Retain a copy with permit
ICON- 60/1
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 /'LGya20ZN31-3670
+
Permit Inspection Request Line (206) 438-9350 .I..�I`' a._
Project
K T 1
Type of Inspect oit`�`''"`' �'`
/11.Reh Ati4.
-----
Address:
5 z< 5 kilAA co
/o/
Date Called:
Special Instructions:
Date Wanted:
7 —2Z -1
a.m.
p.m.
Requester:
Phone No:
xiApproved per applicable codes. Corrections required prior to approval.
COMMENTS:
c-o"
AO- r
Nip
Inspector:
Date:
�z•(—/-
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit.
INSPECTION NO. PERMIT NO.
q-oz-fcr
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350 Ptak p(rfticv„, ttzt
Projtettox
Type of Inspection:
rtf-ectt. PrkCqi
Address:
31/ 7.5 $0 t ( fC fillff° (
Date Called:
Special Instructions:
Ai
'
-
Date yed.5a.m.
Want
.7 _ a_
p.m.
Requester:
7eS-SI.C., e6)) (Pktorit, I A
Phone No:
7O6 7S6- 75" 7- 43
I.:Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
crt,telleei
inspectoKe
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 438-9350
Project:1Q p.
Type of In=
--
...--
Addmss: 2 _
3 3-1--.
(2.....-, cl---
I II,, -)t
Date Called:
,---,
Special Instructions:
/ tO f
eTt)
Date Wanted:
...s......
Ci '.. f •S
tr i
...a.,11S.
p.m.
'Requester:
Phone No:
.f) 1 b/k
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
4, Nje_e_. smoice S 1T ) a/Li A a, t-r Mai/
5c.V\e4 u1.()
I.
Instor-
°
Date:
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NUMBER
/5-F--1/
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT ma Ggi-(
206-575-4407
Project:
cvtf-?
Type of Inspection:
A
Address:
Suite #: 337 S
S . 11tp,"` .
to i
Contac Person:
Special Instructions:
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Add /-a4c,f
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:
i "Ay i `�
Date: 7/at 1t r
Hrs.:
/
0
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
3/14/14
T.F.D. Form F.P. 113
FILE COPY
P?rmit No.
Carrier
United Technologies
SUBMITTAL
Project
Gateway North
Date
Tuesday, November 25, 2014
MI'*O'9
REVIEWED FOR
CODE COMPLIANCE
APPROVED
DEC 12 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 1 0 2014
PERMIT CENTER
6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
6T GasEle-460v
Tag Cover Sheet
Unit Report
Certified Drawing
Performance Report
Unit Feature Sheet
Packaged Rooftop Builder 1.39m Page 2 of 10
Unit Report For 6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
Unit Parameters
Unit Model* 48TCDA07A2A6-0A0A0
Unit Size. 07 (6 Tons)
Volts -Phase -Hertz* 460-3-60
Heating Type. Gas
Duct Cfg• Vertical Supply / Vertical Return
Low Heat
Round Tube Plate Fin Coils
Lines and Filters
Gas Line Size. 1/2
Condensate Drain Line Size. 3/4
Return Air Filter Type* Throwaway
Return Air Filter Quantity. 4
Return Air Filter Size. 16 x 16 x 2
Unit Configuration
Medium Static Option
Al/Cu - Al/Cu
Base Electromechanical Controls
Standard Packaging
Warranty Information
1-Year parts(std.)
5-Year compressor parts(std.)
10-Year heat exchanger - Aluminized(std.)
No optional warranties were selected.
Dimensions (ft. in.) & Weight (Ib.) ***
Unit Length* 6' 2.375"
Unit Width. 3' 8"
Unit Height* 3' 5.375"
*** Total Operating Weight* 712 lb
*** Weights and Dimensions are approximate. Weight does
not include unit packaging. Approximate dimensions are
provided primarily for shipping purposes. For exact
dimensions and weights, refer to appropriate product
data catalog.
NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods.
Ordering Information
Part Number
Description
Quantity
48TCDA07A2A6-0A0A0
Rooftop Unit
1
Base Unit
Medium Static Option
None
None
Accessories
CRECOMZR020A02
Standard Leak Vertical EconoMi$er IV with solid-state controller
1
Packaged Rooftop Builder 1.39m
Page 3 of 10
Certified Drawing for 6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
NOTESI
1. DIMENSIONS ARE IN INCHES DINENSIONS
IN I 1 ARE IN NILLINETEGS.
2. CENTER OF GRAVITY
3.
DIRECTION OF AIR FLOW
FILTER ACCESS PANEL
(TOOL -LESS)
•
INDOOR COIL
ACCESS PANEL
3-3/4
(951 46 3/4
11181)
COMP.
ACCESS
PANEL
BACK
OPTIONAL
FACTORY
INSTALLED
CONVENIENCE
OUTLET
LEFT
UNIT
48TC-A04
33 3/8
[8411
18 5/8
[4121
48TC-A05
33 3/8
[841]
14 7/8
[3711
48TC-A06
33 3/8
[8471
14 7/8
[311)
48TC-A07
41 3/8
[10511
14 7/8
[3771
CONDENSER
COIL
2-5/8
[671
TIP
CURB
WIDTH
44
4-5/8
1118)
LECTR(CAL
DISCONNECT
LOCATION
19.1/2
14941
32 1/4 —'
1818]
18-1/0 1 i }
[4591
16-1/8 14-1/4 12-114
[all) [363] 13121
1 + I I
OPTIONAL
FACTORY
INSTALLED
DISCONNECT
SEE TNRU THE
BASE CHART
33 3/8
(8481
C
UNITED P.o. 003 au
TECHNOLOGIES S1PN0NSF. NT
CARRIER ISRn
ANDS 00[DM[NT IS TNC IIOIE31l 01 CAPNIFE [M100)TNT
AND IS CFSINF[NO UNB T0F n0000 C0ID1 TI1N LINT THE
ioi101AT ❑[L NOT 6[ DISCLOSED M WIN NITIIOuI CAINI [1
Wouna'3 wm[N coNs[rt.
500NISSOT IX TPEN[ OPINIEOS I 0AEUEEONS
DD[s NDl ainlUTE PART PErtuN 2 a
I11ANE( IX CpINAtI.
ECONOMIZER HOOD
(OPTIONAL)
16
[4061
�T
2S-S/8
[6521
RETURN AIR
10-T/8
12171
E ALT.
CONDENSATE
DRAIN OPENING
IN BASEPAN
17-3/4
[4511
SUPPLY
AIR
6-1/4
1571
25
16361
HANDLE
30 1/8
[7641
4
[100]
14 3/8
118881 ---- 31 1/A
17931
i LUE
HOOD
TOP
8-3/13
[2131
1
3-3/8
12-1/5 [851
13071
18-1/2 —�
[4101
RETURN
AIR
11-3/8
CONNECTION SIZES
A
1 3/8' (351 DIA FIELD POWER SUPPLY HOLE
B
2' 150) DIA POWER SUPPLY KNOCKOUT
C
1 3/4' 151) DIA GAUGE ACCESS PLUG
D
1/8' 1221 DIA FIELD CONTROL WIRING HOLE
L
3/4'-14 NPT CONDENSATE DRAIN
F
1/2.-14 NPT GAS CONNECTION
6
2 1/2 ' C641 DIA POWER SUPPLY KNOCK -OUT
TNRU-THE-BA E CHART
THESE HOLES REOUIRED FOR USE
CRBTNPWROO1A01, 003A01
THREADED
WIRE
REO'D HOLE
CONDUIT SIZE
USE
SIZES INAE.)
W
1/Z'
ACC.
7/8' 122.2]
A
1/2'
24V
7/8' 122.2]
Y .
3/4' 1001.001)
POWER
1 1/8' [28.4]
2..
(0031 1/2' OPT
GAS
1 3/16' [30.01
FOR 'TNRU-THE-BASEPAN' FACTORY OPTION,
FITTINGS FOR ONLY N,Y. 8 2 ARE PROVIDED
SELECT EITHER 3/4' OR 1/2'
FOR POWER. DEPENDING ON WIRE SIZE
A
(001) PROVIDES 3/4' OPT TNRU CURB
FLANGE 6 FITTING.
FRONT
SUPPLY
AIR RETURN
RIGHT AIR
1-1(4
OUTSIDE
AIR
441.
21-1/4
15391
BAROMETRIC
RELIEF
FLOW
SHEET
1 OF
DAn
11-24-08
0U1RCEDt3
09-29-08
48TC 04-07 SINGLE ZONE ELECTRICAL
COOLING WITH GAS HEAT
48TM500993
NET
5.0
Packaged Rooftop Builder 1.39m
Page 4 of 10
DATE: 1 / 07
SUBMITTED TO
COMPANY:
DRAWN BY.
JOB NAME
EQUIPMENT:
NOTES'
FEATURES:
• Gear driven dampers eliminate slippage associated with stan-
dard linkage.
• Designed specifically for down discharge applications. Easy to
install. Easy to service.
• Lower static pressure loss through economizer dampers.
• Greater barometric relief capabilities.
• Factory assembled rainhood with aluminum filters in both out-
side air and relief hoods.
• Uses filter access door shipped with HVAC unit.
• Rainhoods are sloped for
water run-off.
• Hardware loth over
relief damper.
Down Discharge Economizer with 100% Relief
Capability for Carrier 48/50TC A/B04-A/B07;
50TCQ A04-A07; 48/50HC A04-A06;
48/50TF,TM,HJ,TFQ 004-007; 48/50HE 003-006 Units
025
0.2
0.15
O.1
0➢5
0
0688-0101 Static Pressure Loss
Through Economizer
Return Alr
Outll de Alr
0 S00 tom 1500 2000
Airflow (cfrry
2500
3000
ECONOMIZER
PART NO.S
0688-0101-00920
Economizer w/ no controls
0688-0101-9J920
Economizerw/fixed
dry bulb controls
----f—
0688-0101-54920
Economizer WI modulating
enthalpy controls
0688-0101-9A920
Economizer w/ modulating
adjustable dry bulb controls
Economizer motor
and harness
Gear driven
dampers
19 1/4"
Weight = 631bs
Sloped
Economizer includes
Honeywell W7212
controller capable of CO2, JJ Outside
demand control and power air
exhaust control.
Rainhood ships
fully assembled
Part Number:
0688-0101
3om
2503
31
v20m
3
:E 1503
tom
SIB
0
0688-0101 Barometric Relief
O
0.05
Access door
shipped with
HVAC unit
Aluminum water en-
trainment filters
Relief air
0.1 0.15 0.2 0.25
Static Pressure (inw.g.J
Drive gear
attached to
the motor
Side View
03
THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT.
MICROMETL CORPORATION • 3035 N. SHADELAND AVENUE, SUITE 300 • INDIANAPOLIS. IN. 46226 • 1-800-662-4822 ••• MICROMETL WEST • 202 SOUTH 18TH ST. - SPARKS, NV 89431 • 1-800-884-4662
Certified Drawing for 6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
/ B
G\\
Service
Clearance
,•
toss,
LOCATION
DIMENSION
CONDITION
A
48-In (1219 mm)
• Unit disconnect is mounted en panel
18-in (457 mm)
• No disconnect, convenience outlet option
• Recommended service clearance
12-in (305 mmj
• Minimum clearance
8
42-in (1067 mm)
•Surface behind servicer is grounded (e.g.. metal, masonry wall)
36-in (914 mm)
•Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass)
Special
•Check for sources of flue products within 10- ft. of unit fresh air intake hood
C
36-in (914 mm)
• Side condensate drain is used
18-in (457 mm)
• Minimum clearance
D
43-in (1219 mm)
• No flue discharge accessory installed, surface Is combustible material
42-in (1067 mm)
• Surface behind servicer is grounded (e.g., metal, masonry wall, another unit)
36-in (914 mm)
• Surface behind servicer Is electrically non-conductive (e.g., wood, fiberglass)
Special
• Check for adjacent units or building fresh air intakes within 10- ft. of this unit's
flue outlet
NOTE: Unit not designed to have overhead obstruction. Contact Application Engineering for guidance on any
application planning overhead obstruction or vertical clearances.
Packaged Rooftop Builder 1.39m Page 6 of 10
Certified Drawing for 6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
0117
STD. UNIT
WEIGHT
CORNER
WEIGHT IA)
CORNER
WEIGHT 181
CORNER
WEIGHT IC)
CORNER
WEIGHT (0)
C.G.
NEI6HT
LBS.
KG.
LBS.
KG.
LBS.
KG.
LBS.
KG.
LBS.
KG.
K
T
Z
/81C-404
483
219
111
50
125
57
131
59
116
53
39 19911
23 [5841
16 3/8 14161
481C-805
537
244
124
56
139
63
145
66
129
59
39 19911
23 [5841
17 14321
481C-806
569
258
131
59
1/1
61
154
70
131
62
39 19911
23 [5841
17 1/4 14381
/87C-407
652
296
150
68
169
16
176
80
157
71
39 19911
23 15841
20 1/8 [5111
CORNER A
TOP
OO I 1 : 00
FRONT
UNITED P.O. POI TWOS
TECHNOLOGIES ...HE. 1I
CARRIER 13111
THIS MOMENT IS Inc PIUPE1lY Or CAIIIEI C6R101AT101
C0t3 1O3 EW)[1t0 O3(EPHEO3
colrounaa 'HITTER 80x3(1r. roBS[100 10W)I 0i1XOTUHT ACT A111PEI [1
S 0CN 01 T1[SE OPA1116S 10 18CUEE1S
0oca iroluiiiieici aPra�anP�wxAxcE oN
CORNER B
CORNER C
SNIFF
2 OF 2
OAR
11-24-08
VIERCHES
09-29-08
48TC 04-07 SINGLE ZONE ELECTRICAL
COOLING WITH GAS HEAT
48TM500993
5.0
Packaged Rooftop Builder 1.39m Page 5 of 10
Performance Summary For 6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
Part Number:48TCDA07A2A6-0A0A0
ARI EER. 11.00
IEER. 11.2
Base Unit Dimensions
Unit Length* 74.4 in
Unit Width. 44.0 in
Unit Height 41.4 in
Operating Weight
Base Unit Weight 652 lb
Medium Static Option. 10 lb
Accessories
Standard Leak Vertical EconoMi$er IV with solid-state controller 50 lb
Total Operating Weight 712 lb
Unit
Unit Voltage -Phase -Hertz* 460-3-60
Air Discharge' Vertical
Fan Drive Type. Belt
Actual Airflow. 2400 CFM
Site Altitude. 0 ft
Cooling Performance
Condenser Entering Air DB. 95.0 F
Evaporator Entering Air DB. 80.0 F
Evaporator Entering Air WB. 67.0 F
Entering Air Enthalpy• 31.44 BTU/lb
Evaporator Leaving Air DB. 57.6 F
Evaporator Leaving Air WB. 57.1 F
Evaporator Leaving Air Enthalpy• 24.47 BTU/Ib
Gross Cooling Capacity' 75.21 MBH
Gross Sensible Capacity' 58.11 MBH
Compressor Power Input' 5.11 kW
Coil Bypass Factor. 0.084
Heating Performance
Heating Airflow. 2400 CFM
Entering Air Temp. 70.0 F
Leaving Air Temp. 92.8 F
Gas Input Capacity* 72.0 MBH
Gas Heating Capacity' 59.00 MBH
Temperature Rise. 22.8 F
Supply Fan
External Static Pressure' 0.60 in wg
Options / Accessories Static Pressure
Economizer 0.17 in wg
Total External Static' 0.77 in wg
Fan RPM' 1453
Fan Power 1.97 BHP
NOTE' Selected IFM RPM Range: 1173 - 1518
Electrical Data
Voltage Range' 414 - 506
Compressor #1 RLA. 9.7
Compressor #1 LRA- 62
Indoor Fan Motor Type. MED
Indoor Fan Motor FLA. 4.2
Packaged Rooftop Builder 1.39m Page 7 of 10
Performance Summary For 6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
Combustion Fan Motor FLA (ea) 0.25
Power Supply MCA. 18
Power Supply MOCP (Fuse or HACR). 25
Min. Unit Disconnect FLA. 17
Min. Unit Disconnect LRA. 100
Electrical Convenience Outlet None
Outdoor Fan [Qty / FLA (ea)]. 1 / 0.8
Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage
Acoustics
Sound Power Levels, db re 10E-12 Watts
Discharge Inlet Outdoor
63 Hz 89.8 88.6 88.8
125 Hz 85.6 82.5 81.8
250 Hz 80.1 70.7 76.9
500 Hz 75.5 66.8 74.4
1000 Hz 71.9 66.0 73.3
2000 Hz 66.4 60.6 69.8
4000 Hz 68.2 56.7 66.3
8000 Hz 64.3 50.0 62.7
A -Weighted 78.7 72.1 78.0
Advanced Acoustics
Advanced Accoustics Parameters
1. Unit height above ground. 30.0 ft
2. Horizontal distance from unit to receiver 50.0 ft
3. Receiver height above ground. 5.7 ft
4. Height of obstruction. 0.0 ft
5. Horizontal distance from obstruction to receiver 0.0 ft
6. Horizontal distance from unit to obstruction. 0.0 ft
Detailed Acoustics Information
Octave Band Center Freq. Hz
63
125
250
500
1k
2k
4k
8k
Overall
A
88.8
81.8
76.9
74.4
73.3
69.8
66.3
62.7
90.1 Lw
B
62.6
65.7
68.3
71.2
73.3
71.0
67.3
61.6
78.2 LwA
C
56.4
49.4
44.5
42.0
40.9
37.4
33.9
30.3
57.7 Lp
D
30.2
33.3
35.9
38.8
40.9
38.6
34.9
29.2
45.8 LpA
Legend
Packaged Rooftop Builder 1.39m Page 8 of 10
Performance Summary For 6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
A Sound Power Levels at Unit's Acoustic Center, Lw
B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA
C Sound Pressure Levels at Specific Distance from Unit, Lp
D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA
Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI
Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed
that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical
estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be
appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate
an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an
Acoustical Engineer or a person with sound prediction expertise should be consulted.
FanCurve
18
16
04
02
L300RPM
1.008FP
•
co
07
03
06 09 12 15 18 21
Articw(CFM-thousands)
RPM=1453 BHP=1.97 MaximumRPM=1585 MaximumBHP=3.70
Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion,
SC -System Curve RP -Rated Point
\,1900RPM
.y150BHP.`..
24
27
210204v1 -
30
5.00B• -
3.70BHP\,
3.00BHP
I 1.
33
Packaged Rooftop Builder 1.39m Page 9 of 10
Unit Feature Sheet for 6T GasEle-460v
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
WeatherMaker` — 48TC
PACKAGED ROOFTOP GAS HEATIN&ELECTRIC COOLING UNITS
3. 4, 5, 6, 7.5, 8.5, 10,12.5.15 TON S
Optional Louvered Hail Guard She ,ri
ISHRA.E
[ V1.1w;;
COMPLIANT
WEATHERMAKER SERIES
Veatherl'A alter (48TC) units are one-piece gas heating. electric
cooling units that are pre -wired and charged with Puron
'P.-41u': refrigerant. They are factory tested in both heating
and cooling modes. and rated in accordance with AHP.I
Standards 210..24cI O4-06 sizes) and 340i360 (07-16 sizes).
•.h'eatherMaker units are designed in accordance Mth UL
Standard 1995, and listed by the Underwriters' Laboratories.
Approved and certifiedby,
US
Certified to ISO 9001
STANDARD FEATURE S INCLUDE:
• P''JOn n-:1051.rc refr.ggr3'1i
• S1-R4E 93.1 enen]y conDlent
• Scrod T•oresoora wan 'ntem9'i-ne ovarood o'otecton
• S.na,ealo e,0olina oa0a,'ry,ontro' on 04-12 modese
• ',.a-siege,]ot:ng CSDaaty,oniro, on 05-15 mods a
• SEEFra LID to 13:3. EER a J0 to 11.1 and IEER'a u0 to 11.o
• .4,u1'oin, refr;gerantrneier;ng .;stem
• ExoitlEVE non-,Drrosive',omoasit=_ 0:09:ien33le Den accordance Wan
51-1005 Standard 52, s.oana des:211. s:5e orcenlero ror
• Stand5'd soo'ng 005r3t.,3n J0 to 115'; ;GS'O; and1y.•.'r1 to :3'r,
• down t]25'F,^ :::x^nv:nte"stenkti.
• =re -dented exte,]'03ne. and Dnrer-::oa!d-ols-,' D3 n-;-lasted t0
500no.?s3') ;Dray oratesvon - -- -
• -o1iy maxis ted,=_onat
• Ex: Js =_ l C- so.d ;:ate :oniro. fo' on-o]a-11 ag•'o;. _:. *n LE"
e,o-coda dos-gnot:on0J11e':]n1'Ji or: and energy� aevng' door
fa_n ^1013•-zia'3'v
• Lon,: i- x nodal. tnet ^,et: COO-ty L'00 )e Rnl
• IndJ:ed draft -ilea nast :D,Ouivon ic3'.7'n
• P.edundsnl gel•:3..:05 WOO .101131a- tsgea of .nee: no
1
• o.'. DresaJ'e 5n.d n:J5 n D'esJre _.,'Sri -
MAINTENANCE FEATURES:
• 03nea:.1n e35y] - 11,11,a2
• Innoyet,e n: ] - : .05 on J"1,: a .sne 5
• n n1 so,, .1 ?a•oT]]-a f3 •- --..c.
• _n: ._ evadorel013n mold e 1 oJ'ev:o,dn_1o,s
• te"nna' o03r1 safety:'':JR :'0J0 ea -no -ding and
.morf.ed .oniro Dos a -anger -yen',
• Ex:Js^:e n3 =- ao',d-state :11.1.1'0-fJ' 3n-003'1 d agn1st0 10.00 LE..
err0rg0de e;-anat'Dn. 0Jr!rer000I13 :0g , 2,13 ene'gy a3.ng:nd]r
fan "V 7'].' de 3 y".
INSTALLATION FEATURES:
• 7nrJ-1ne-03110m00'001S0LN:s030'tly
• S.na_-e oantasaand eecta:00100010na
• rU' Oenme:er Dese rbd ,r.:n DJ.a.n ad=0101; and fOr.- 5 0l'
• Fe:.onsen:d!s from •ve ' to n0,001t3 3"f ow for snail ^l]Unt nil.
;:1.5 s,e models reaU+'3 'read-na.5.ed 2JDOiy'1J2.1 •33,ar.
STANDARD WARRANTY:
• 10-yssr heal cool ros'_ 15-,,aer s1.3m'eaa ;leer ]ot:0n
• 5.1e5'c0T0'eaa0•
• 1-yearda^15
• 3-year Ds Dn Novafon Condenae'AS
• M3nyooton3!uo}3des 5;503u5;'a01a
Die
OPTIONS INCLUDE BUT ARE NOT LIMITED TO:
• ?'s'0SrLin:,'° end!'L. moan lolut- Pronto DOC
• SCusoly and 00IJ^1 4r• 7r,3;w; C515:10?. h:oh ;t51-': '00l0?
• Lo ova ed sondenzer - .IJ3 di
• E:on]m_:,d=annest sod c0nvencnie oJt51o010ns
• S15 n'ese Sias' nest ex,nangaroot ]n
• t-or-os on -es slant :0: ,001,ng.
• !-.J m.1-1,1'ze' 3da01,.e 1enJn-,d:f:51Jn 3y3te^.3•F3 30t ]n 3-
'o.33a ..., -PF .Dn 13 l,'-,D 21e ! ." .. , ;' n:'J9e
•
F]'a :'J"r0'S10 'Et of 501.Jn's ends. "ea"o ea'era- 10 Ina .-D1J:1 Data
Packaged Rooftop Builder 1.39m Page 10 of 10
FILE COPY
P 'rr !t No.
0 WAS11
,<Q' ZG
1
4) T18959.
zcss/ONA L EN�
STRUCTURAL
CALCULATIONS
Gateway North RTU
3225 South 116th Street
Tukwila, Washington
DECEMBER 1, 2014
PREPARED FOR:
Comfort Mechanical
3202 C Street NE
Auburn, Washington 98002
PREPARED BY:
Moore Engineering Group
21902 96th Avenue SE
Snohomish, Washington
More
Engineering
Group
REVIEWED FOR
CODE COMPLIANCE
APPROVED
DEC 12 2014
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
DEC 10 2014
PERMIT CENTER
GENERAL STRUCTURAL NOTES:
1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO
THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2012 EDITION.
2. DESIGN LOADING CRITERIA:
ROOF LIVE LOAD 25 PSF
MECHANICAL UNIT 827 POUNDS
EARTHQUAKE SDS = 0.961
SITE CLASS D to E
WIND 85 MPH, EXPOSURE B
3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION
WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR
SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL
NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION.
4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND
CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING
CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE
VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED
EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON
EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH
THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE
OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO
COMMENCING ANY WORK.
5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND
STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN
COMPLETED IN ACCORDANCE WITH THE DRAWINGS.
6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE
METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE
COMPLETION OF THE WORK.
7. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL
INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL
STRUCTURAL MEMBERS".
8. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM
A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH.
9. CONNECT THE NEW UNITS TO THE METAL CURB WITH A MINIMUM OF (2) #10 SHEET
METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM
EACH CORNER OF THE UNIT.
10. AS AN OPTION FOR ANCHORAGE OF THE UNIT, CONNECT THE NEW UNIT TO THE
METAL CURB WITH AN 18 GAGE x 2-1/2" WIDE GALVANIZED METAL STRAP WITH (2)
#10 SHEET METAL SCREWS INTO BOTH THE UNIT AND CURB IN EACH CORNER OF THE
UNIT AS SHOWN ON THE ATTACHED PLAN.
PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop
mechanical unit with a new unit.
LOADS: LIVE 25 PSF
DEAD
Roofing and re -roof 4.0
1/2" Plywood sheathing 1.5
2x6 @ 24" o.c. 1.1
4x14 @ 8' o.c. 1.5
Insulation 1.0
MEP 2.0
Ceiling & Lights 2.9
Total Dead 14
DEAD + LIVE
WIND 85 mph, Exposure B
SEISMIC
39 PSF
Latitude 47.498
Longitude -122.291
Site Class D to E WA DNR
SDs (D) = 1.011
SDs (E) = 0.910
SDs = 0.961
EQUIPMENT
Existing New
Unit 649 712
Existing Curb 115 115
Total 764 827
Dimensions 74"x44"x53" high
Moore
Engineering
Group
PROJECT:
GATEWAY NORTH
RTU
ENGR: KWM
DATE: 12/ 1 / 14
SCALE:
SHEET
' Design Maps Summary Report Page 1 of 2
MUSES Design Maps Summary Report
User -Specified Input
Report Title Gateway North RTU
Thu November 27. 2014 17:17:45 UTC
Building Code Reference Document 2012 International Building Code
(which utilizes USGS hazard data available in 200B)
Site Coordinates 47.498°N, 122.291°W
Site Soil Classification Site Class D - "Stiff Soil"
Risk Category I/II/III
Vashon
il
r'1 allquest
15mi
5000in
USGS-Provided Output
Ss = 1.517 g
= 0.570 g
is �.
White; cERter
'+;' A
a
TFawcastle
Tukwila
,BUtiert_ 1 o r�
\
4 SeaTac
SMs= 1.517 g
SMy = 0.854 g
@2( 4f
Sos = 1.011 g
SDI = 0.570 g
0 'l `j" :
MERICA
East it(
_ (#ighiar
MapQuest
For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
NICER Response Spectrum
1.7e
1.20
1.44
1.2£
1.12
• 0. 02
N 0.00
0.64
0.4£
0.32
0.15
0.00
0.00 0.20 0.40 0.20 0.00 1.00 1.20 1.40 1.60 1.00
Period, T (sec)
2.00
1.10
0.99
0.22
0.77
Ci 0.66
• 0.55
cn
0.44
0.33
0.22
0.11
0.00
0.00
Design Response Spectrum
0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.80
Period, T (sec)
2.00
http://ehp 1-earthquake.cr.usgs.gov/desigmnaps/us/summary.php?template=minimal&latit... 11 /27/2014
.Design Maps Summary Report Page 1 of 2
USGS Design Maps Summary Report
User -Specified Input
Report Title Gateway North RTU
Thu November 37, 2014 17:18:30 UTC
Building Code Reference Document 2012 International Building Code
(which utilizes USGS hazard data available in 2008)
Site Coordinates 47.498°N, 122.291°W
Site Soil Classification Site Class E - "Soft Clay Soil"
Vachon
mapquest
Risk Category I/II/III
s000m
smi
USGS-Provided Output
Ss = 1.517 g
Si = 0.570 g
Sms = 1.365 g
SM1 = 1.367 g
t99
Newcastle
0
rirf4 Y-90r3. East R(
. ,
Highlac
Tukwila 0 I I-1
'It A fv1 E Pi 1 C
if
€.20,4r @ftlatauest
S., = 0.910 g
501 = 0.911 g
For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the "2009 NEHRP" building code reference document.
MCER Response Spectrum
1.10 -
1. 40 - 1.00 -
11
VI
ttl 0.84
0.70 T:11 O.C.0 -
o
to o.so - \\N.,..............„..............
1.12 0.O0 -
0.99 0.70 0..5r.; 0.40
0.42
0.20 -
0.14. 0.10 -
O. 00 i I I
1
1 1 I i i I 0.00
0.00 0.20 0.40 ace O. SO 1.00 1.20 1.40 1.60 1.00 2.00 0.00 0.20 0.40 0.0 ci.eo 1.00 1.20 1.40 1.60 1. SO 2.00
Period, T (sec) Period, T (sec)
Design Response Spectrum
http://ehp4-earthquake.cr.usgs.govidesignmaps/us/summary.php?template=minimal&latit... 11/27/2014
)
1'2!
'
/
t I
0
s)cfCir
e-' -I!
C-
, t .
Pe.
17Y---,1 l<-
F:-1Ffl
')K1I-T•
r-t
Moore
Engineering
Group
) PROJECT:
. - A
ENGR:
DATE: /1 /1,4
SCALE:
1
SHEET
(Ni
C
rss (in
•••
..4.-..,
P
N-4•4
- -
0
'\...1 vs
,, XI-
,_ "#`1'
\ /
,
• tk
•0 —
.1.
X
'co [
f•
.
x 1
'1'4 '''
3
\+s
° •4
'.- N
M
i , , •
a-
1 vA.
Physical data
BASE UNIT 48
DJE004
DJD/DJE005
DJD/DJE006
DJD/DJE007
NOMINAL CAPACITY
3
4
5
6
OPERATING WEIGHT (Ib)
Unit
530
540
560
615
With Economizer
564
574
594
649
Roof Curb
115
115
115
115
COMPRESSOR
Hermetic
Quantity
1
1
1
1
Oil (oz)
55
55
70
70
REFRIGERANT TYPE
R-22
Operating Charge (Ib-oz)
3-13 5-8 6-11 9-0
CONDENSER FAN
Propeller
Quantity...Diameter (In.)
1..26
1 .26
1.. 26
1 . 26
Nominal Cfm
3500
4100
4100
3800
Motor Hp...Rpm
'S. 850
Vs 850
1 850
1 850
CONDENSER COIL
Enhanced Copper Tubes,
Aluminum Lanced Fin
Rows...Fins/In.
1...17
1.17
1...17
2.. 17
Total Face, Area (sq ft)
7.78
12 25
12.25
12 25
EVAPORATOR FAN
Centrifugal
Size(In.)
10x10
10x10
10x10
10x10
Type Drive Std
Direct
Direct
Direct
Belt
Alt
Direct
Bell
Bell
Belt
Nominal Cfm
1200
1600
2000
2400
Horsepower per National Std
1
v2
%
1 0
Electrical Code (NEC)' Aft
+h
=ya
1.0
1.6
Maximum Continuous bhp Std
38
87
1 29
1 70
Alt
78
1.30
1.70
2.40
Motor Frame Std
48
48
48
56
Alt
48
56
56
56
Nominal Rpm High/Low SW
860/845
1080/970
1080/1040
—
Alt
1080/970
—
—
—
Fan Rpm Range Std
—
—
875-1190
Alt
—
800-1130
875-1190
1070-1460
Motor Bearing Type
Ball
Ball
Ball
Ball
Maximum Fan Rpm
2100
2100
2100
2100
Motor Pulley Pitch Diameter Std
—
2.8-3.8
A/B (In.) Alt
—
2 4.3 4
2 8-3 8
2.8-3.8
Fan Pulley Pitch Diameter (in.) Std
—
—
5 2
—
5 5
Belt — Type...Length (In.) Std
—
—
° 5
A4 40
Alt
—
A 40
A 40
A..39
Pulley Center Line Distance (In.) Std
—
14 7-15.5
Alt
—
14 7.15.5
147-15.5
14 7-15 5
Speed Change Per Full Turn of Std
—
—
—
63
Movable Pulley Flange (rpm) Alt
Movable Pulley Maximum Full SW
—
—
66
63
79
5
Turns from Closed Position Alt
—
5
5
5
Factory Setting — Full Turns Open Std
Alt
—
—
—
3
—
3
3
Factory Speed Setting (rpm) Std
—
1000
All
—
930
1000
1230
Fan Shaft Diameter at Pulley (In.)
—
%
%
s
EVAPORATOR COIL
Enhanced Copper Tubes,
Aluminum Double WavyFin
Rows...Fins/in.
2. 15
2...15
3.. 15
4.. 15
Total Face Area (sq ft)
4 17
5.5
5 5
5 5
FURNACE SECTION
Burner Orifice Diameter (In. _.drill size)t
Natural Gas — Std
113...33
.113 33
113...33
113.. 33
Liquid Propane — Alt
089..43
080 43
089,. 43
089 43
Thermostat Heat Anticipator Setting (amps)
208/230/460 v
1.0
1 0
1 0
1 0
Gas Input
74,000
74,000/115,00
74,000/115,000
74,000/115,000
Efficiency (Steady State) (%)
80
80
80
80
Temperature Rise Range
Manifold Pressure (in. wg)
25-55
25-55/35-65
25-55/35-65
25-55/35-85
Natural Gas — Std
3 5
3 5
3.5
3 5
Liquid Propane — Alt
3.5
3.5
3.5
3.5
Maximum Static Pressure (In. wg)
75
75
75
75
Field Gas Connection Size (In.)
5 :
5
5
5
HIGH-PRESSURE SWITCH (psig)
Cutout
428
Reset (Auto.)
320
LOSS-OF-CHARGE/LOW-PRESSURE SWITCH
(Liquid Line) (psig)
Cutout
7 ± 3
Reset (Auto.)
22 ± 5
OUTSIDE -AIR INLET SCREENS
Quantity...Size (In.)
Cleanable
1..20x24x1
RETURN -AIR FILTERS
Disposable
Ouantlty...Size (in.)
2 16 x 25 x 2
LEGEND
Bhp — Brake Horsepower
'Used to determine wire sizing per NEC
t48DJD005-07 and 48DJE004 (74,000 Btuh) units have 2 burners
481:JE005-007 (115.000 Biuh) units have 3 burners.
•
•
Base unit dimensions — 48DJ004-007
I440)
0,117
19021
0'-7 1/4'
[1841
0'-10 13/1.'
[2751
RETURN -
AIR
OPENING
HORI-
ZONTAL
7'
[1781
0'-4 1/16'
[103)
FILTER ACCES5 PANEL
(DISPOSABLE FILTERS)
2'-1 I1/16'
C653)
ACCESSORY
HOOD FILTER
1' 11 1/4'
OUTSIDE AIR
0'-5 3/4'� '-1 1S/1•' 0'-5 11/16'
(146) . . C659) [1441
SUPPLY AIR RETURN AIR
E STD CONDENSATE DRAIN (INTERNALLY
NOTES: R I GHT SIDE TRAPPED)
1 Dimensions in j I are in millimeters,
2‘13 Center of Gravity.
3 'V///j Direction of airflow
4 Ductwork to be attached to accessory roof
curb only
5 Minimum clearance (local codes orjuris-
diction may prevail):
a
Between unit, flue side and combus-
tible surfaces, 36 inches
b Bottom to combustible surfaces (when
not using curb), 14 Inches
c Condenser coil, for proper airflow, 36-
in. one side, 12 In the other The
side getting the greater clearance Is
optional
d Overhead, 60 In. to assure proper con-
denser Ian operation
e Between units, control box side, 42
inches
f Between unit and ungrounded sur-
faces, control box side, 36 inches
g Between unit and block or concrete
walls and other grounded surfaces,
control box side, 42 Inches
h Horizontal supply and return end, 0
inches
8 With the exception of the clearance for
the condenser cog and combustion side,
as stated in notes 5a, b and c, a remov
able fence or barricade requires no
clearance
Connection Sixes
A
13s" Die 1351 Field Power Supply Hole
a
2" Be 1511 Power Supply Knockout
C
134" Dia 144) Charging -Pon Hole
D
Y6' Dia 122j Field Control Wiring Hole
E
34'•14 !VT Condensate Drain
F
WI4 NPT Gas Connection
G
2 W' Dia 1641 Power Supply Knockout
ELECTRICAL t 0'-7 3/8
DISCONNECT I1e71 —
LOCATION
2'-9 5/16'
[8 7)
807TLRi
OF UNIT
0'-4 9/16".1 I TYP 3' S 3/16'
I1161 ej tF (10461
0'-2 9/16'
[657 LEFT SIDE
CORNER 'A'�
UNIT
STD
UNIT
WEIGHT
ECONOMIZER
WEIGHT
CORNER
WE GHT
(A)
CORNER
WE GHT
(B)
Lb
Kg
Lb
Kg
Lb
Kg
Lb
Kg
48DJE004
630
240
34
15 4
104
47.2
97
44 0
48DJE/DJ0006
540
245
34
15.4
106
48 1
98
44 5
48DJE/DJ0006
560
254
34
15 4
110
48 9
102
46 3
48DJE/DJDO07
615
279
34
15 4
120
54 4
112
50 8
UNIT
CORNER
WEIGHT
(C)
CORNER
WE GRIT
(D)
"H"
Lb
Kg
Lb
Kg
Ft•In.
mm
48DJE004
159
72 1
171
77.6
3.11/4
947
48DJE/DJDO05
162
73 5
174
78 9
1.21/4
362
48DJE/OJDO08
168
76 2
180
81 6
1.21/4
362
480JE/DJ0007
185
83 9
198
89.8
1.21/4
362
T-015116'
tIDell -
FILTER/ECONOMIZER ACCESS PANEL
rCONDENSER COIL
OUTSIDE AIR
,__ 2' -0 15/16".____.
[633)
0'-4 1/2'
OPTIONAL
ECONDMI7ER HOOD
1'-4 3/B'
[416)
Imo --CORNER '8'
3 -9'
(11443
I' 5'
[43?)
CORNER 'D'--"r"."
1/
0'-2 15/16'-"
175
0'-4 5/0'-
(I18)
EVAPORATOR
COIL
rI (652)
RETURNS IRCOPENING
L
ALT. CONDENSATE
)RAIN OPENING
IN BASEPAN
TM0'-3 3/16'
• [81)
1 RETURN AIR
0'-10 15/16' ' 05lO
[2781 rr
I � (13773/8'
(
SUPPLY -AIR
OPEN IN6
VERTICAL
I `0'-? 9/16'
C651
I'-5 3/4'
(4511
j
0'-5 7/16'
C136)
-4 9/16' [725 5)-0 0'-3 1/16' 6'-I I1/16' fie)7B)
[1972)
•0'-(973
3 13/16'
B FLUE HOOD
5/16'
[4151
0'-6 5/8'
(1691
2'-11 I/T i
[9G2)
FRONT
I3067
SUPPLY AIR
0'0'-3CORNER'C'
�CO1)
1'-5
CONTROL 60X/
CORPRE550R/
BURNER ACCESS
PANEL
0'-4 3/16'
[IO 71
1
7/16".
(4431
IN000A-FAN MOTOR 6
BLOWER ACCESS PANEL
U'
f
:%OO I
1
1
/4
1 QOO,
5 3/8' i
CI461 7/t8'
ORK TRUCK SLOTS /
0'-e
[2t41 0'-2 I/4'0IA
[571
(TYP 8 PLACES)
FRONT
0'-0 3/6'
n07
CN�
Project: Gateway North
Prepared By:
Performance Summary For 6T GasE[e-4€Ov
11/25/2014
09:47AM
Part Number:48TCDA07A2A6-0AOAO
ARI EER:.. 11.00
IEER
....11.2
Base Unit Dimensions
Unit Length. _ 74.4 in
Unit Width: .__...._.........._........._........._ _..._..... 44.0 in
UnitHeigh:.._.._._........._..._....._....----....._.._.........._........_.......__._............_.....----._.................._..............._....._..._............_......._.....4t:4 in
Operating Weight
Base Unit Weight._...._ ................._ 652 lb
Medium Static Option. 10 lb
Accessories
Standard Leak Vertical EconoMi$er IV with solid-state controller_ 50 lb
Total Operating Weight. 712 lb
Unit
UnitVoltage-Phase-Hertz:._............................._...............-....._...._................._.._......................._...-....-..................._................460-3-60
Air Discharge:. Vertical
Fan Drive Type. . .Belt
Actual Airflow' 2400 CFM
Site Altitude:....... ..... _______ ........... 0 ft
Cooling Performance
Condenser Entering Air DB• 95.0 F
Evaporator Entering Air DB: 80.0 •F
Evaporator Entering Air WB:.._ 67.0 F
Entering Air Enthalpy:._...._......._..... ._........... .................._.._31.44 BTU/lb
EvaporatorLeaving Air DB:.._......................................._................_..._................._......._..................._......................................_57.6 F
EvaporatorLeaving Air WB:..... ...-.... .......__................... _........... ..........:.......... ......._.................. -............. .......... ..... ................_67.1 F
Evaporator Leaving Air Enthalpy• 24.47 BTU/lb
Gross Cooling Capacity 76.21 MBH
Gross Sensible Capacity* 58.11 MBH
Compressor Power Input:.. . 5.11 kW
Coil Bypass Factor:... ....... 0.064
Heating Performance
Heating Airflow. 2400 CFM
Entering Air Temp:..._.. ............ _ ..... ____
LeavingAir Temp:.._-..--...__.._..._......................_.....__......._..._............_.............._ 92.8 F
Gas Input Capacity:.__......._ ........... .._........... ..-....................... 72.0 MBH
Gas Heating Capacity. 59.00 MBH
Temperature Rise' 22.8 F
Supply Fan
External Static Pressure: ......... ..... ...... ........ 0.60 in wg
Options / Accessories Static Pressure
Economizer
Total External Static. 0.77 in wg
FanRPM :.. ....................._.............._....... 1453
Fan Power
.................. .
1.97 BHP
NOTE Selected IFM RPM Range: 1173 -1518
........ ....................... ...._..... .0.17 in wg
Electrical Data
Voltage Range 414 -506
Compressor #1 RLA:..... .......................... .._ 9.7
Compressor #1 LRA:........................._........._.. .... ............_...._..62
Indoor Fan Motor Type- MEED
Indoor Fan Motor FLA•
;',•cicaged Rooftop Buiroer 1.39m Pne 7 of 10
Certified Drawing for 6T GasEle-460a
Project: Gateway North
Prepared By:
11/25/2014
09:47AM
Hill
S1D. UNIT
REI0H1
CORKER
11EIG111 I0)
CORKER
♦E1011'101
CORNER
YEI6N7 ICI
CORKER
WE16HT 01
C.G.
HEIGR1
LOS.
SG.
LS1.
KG.
1.61.
NO.
16S.
10.
E05.
NG.
1
1
2
1116-644
4R3
111
111
50
125
SR
131
5R
116
53
39 111)]
23.15543
16 315 14111
4412-613
511
244
124
51
13S
13
145
00
121
51
31 11111
23 (564)
17 14321
401(.111
561
256
131
'6!
147
61
154
70
131
62
39 11111
23 15041
17 114 14361
1110•611
652
211
150
65
161
16
176
80
157
II
31 11111
23 15041
20 110 (5111
10P
T[WMO(OGIES 1.1wl. 44
CARRIER 14*3
f+u 1a�.1a ss n1 ..ae.v > ua¢< 1wrm,le.
'""...Isn%.81°Ii'.ttt
�N04M1101'f Ht111f. IHR4tlt.
CORNER 8
CORNER C
1.
ri00 ! I i l a, �. : 00E
LJ
FRONT
NMI
2 Of
0.01
11-24-08
ail<IeE.
09-29-08
481C 04-07 SINGLE ZONE ELECTRICAL
COOLING WITH GAS HEAT
48714500993 >JK.O
Packaged Rooftop Builder 1.39m
Page 5 of 10
I�4
\.\ I L4 , ~
(-
c4 (7
57 c
Lr��e'ref
a
7'4
CL
{i L
Moore
engineering
roup
PROJECT:
_.. 6•ti� f � �i ff,
ENGR`
DATE:
SCALE:
SH
City of Tukwila
Department of Community Development
7/1/2015
JESSE CHUTICH
3202 C STREET NE
AUBURN, WA 98002
RE: Permit No. M14-0219
RPI
3325 S 116TH ST STE 101
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric
Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null
and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if
the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180
days. Your permit will expire on 8/26/2015.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 8/26/2015, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Bill Rambo
Permit Technician
File No: M14-0219
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
PERMIT NUMBER: M14-0219 DATE: 12/10/14
PROJECT NAME: RPI
SITE ADDRESS: 3325 S 116 ST
X Original Plan Submittal
Revision #
before Permit Issued
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
AT t ,H`1i Li 4/�ijC P---1 /
Building Division Fire Prevention
Public Works
Structural
Planning Division
Permit Coordinator
n
PRELIMINARY REVIEW:
Not Applicable
(no approval/review required)
DATE: 12/11/14
Structural Review Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved
Approved with Conditions
Corrections Required Denied
(corrections entered in Reviews) (ie: Zoning Issues)
DUE DATE: 01/08/15
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
12/18/2013
COMFORT MECHANICAL INC
Page 1 of 2
0 Washington State Department of
Labor & Industries
COMFORT MECHANICAL INC
Owner or tradesperson
JACKSON, SHIRLEY A
Principals
JACKSON, SHIRLEY A, PRESIDENT
JACKSON, HERB J, VICE PRESIDENT
Doing business as
COMFORT MECHANICAL INC
WA UBI No.
601 954 041
3202 C ST NE
AUBURN, WA98002
425-251-9840
KING County
Business type
Corporation
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Construction Contractor Active.
Meets current requirements.
License specialties
Heating/Vent/Air-Conditioning and Refrig
(HVAC/R)
License no.
COMFOMI015LA
Effective — expiration
06/01/1999— 04/25/2016
Bond
Lexon Ins Co
Bond account no.
9815017
$6,000.00
Received by L&I Effective date
06/04/2012 06/01/2012
Expiration date
Until Canceled
Bond history
Insurance
Continental Western Ins Co
Policy no.
CWP6015115
$1,000,000.00
Received by L&I Effective date
05/30/2014 06/01/2014
Expiration date
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 12/24/2014