Loading...
HomeMy WebLinkAboutPermit M14-0219 - RPI - ROOFTOP UNITRPI 3325 S 116 ST M14-0219 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206:431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0923049068 Permit Number: 3325 S 116TH ST 101 Issue Date: Permit Expires On: Project Name: RPI M 14-0219 12/24/2014 6/22/2015 Owner: Name: Address: Contact Person: Name: Address: EPROPERTY TAX INC DEPT 207 PO BOX 4900 , SCOTTSDALE, WA, 85261 JESSE CHUTICH 3202 C STREET NE , AUBURN, WA, 98002 Contractor: Name: COMFORT MECHANICAL INC Address: 3202 C ST NE , AUBURN, WA, 98002 License No: COMFOM1015LA Lender: Name: Address: Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: DESCRIPTION OF WORK: REPLACE (1) 6-TON GAS PACKAGED ROOFTOP UNIT WITH NEW 6-TON TO ROOFTOP UNIT Valuation of Work: $6,673.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $285.10 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized ._,AAMAAcjAW. UV \cjA Date: l2- z (4 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: V.-SS / c, Date: / 24/ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 6: Readily accessible access to roof mounted equipment is required. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 17: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 18: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 19: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 20: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA,gov Mechanical Permit No. '- -4;)0 Project No. Date Application Accepted: 12 t 14 Date Application Expires: (0 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: King Co Assessor's Tax No.: 0 `f 2 30 q -'to c g Tenant Name: R FL Suite Number: 'o 1 Floor: re' PROPERTY OWNER . Name: L- 1 ro0er f7 Address: 3 3•1r S "4 +A S �g7� City: �,,,,,.1 11 State: a Zip: 47/8/ CONTACT PERSON - person receiving all project: communication Name: VCo.SSe. G4 .4. ; cx Address: 3 2 o. c .4.. T_ Jo City: Arot ern State:j _ w,,4 Zip: e(3002 Phone: q Zs. - z St - d QyoFax: Email: `(e cSe (f GOtwrori'nle •Ger'+ New Tenant: D Yes 12r..No MECHANICAL CONTRACTOR INFORMATION Company Name: / � �'J O f oinPr✓A do i,Gaei Address: 's'LG Z C S- N p City: /"'�'1 r krR State:'„ /'/1 Zip4d0O1 `� v J 1' O Phone: ft Z.. S' 2 S—( "t f (�QFax: Contr Reg No.: / ,*., t A j�T-01� pate: cvz4.- ( G A, Y Tukwila Business(LicenseicNo.o.:QGr G 3 S` Valuation of project (contractor's bid price): $ 6,6 73 Describe the scope of work in detail: Re'l die, 0) - s,_S r6G/Ca fn l roof4 r 4tr1; f w►�4 new Use: Residential: New ❑ Commercial: New CI Fuel Type: Electric ❑ Gas Replacement Replacement ❑ Other: H:\Applications\}onns-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-I l.docx Revised: August 2011 bh �i-fo,, of4-413 Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu f Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment tr•S ?gag le. Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: 3 Z 0 Z G$ A/ F H:'Appl icat ions\Forms-AppRom ions On Line1201 I Applications \Mechanical Permit Application Revised 8-9-I I.docx Revised: August 201 I Rh Day Telephone: A City Date: ) to .5- -Zs - €?'$ro VA agooZ State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK �� ACCOUNT QUANTITY r �:� PAID vz $285i10 M14-0219 Address: 3325 S 116TH ST Apn: 0923049068 ` $285 10 MECHANICAL $274.13 ;. PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $186.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $54.83 TECHNOLOGY FEE $10.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R3735 R000.322.900.04.00 0.00 $10.97 $2.85.10 Date Paid: Wednesday, December 10, 2014 Paid By: JESSE CHUTICH COMFORT MECHANIC Pay Method: CREDIT CARD 010182 Printed: Wednesday, December 10, 2014 8:28 AM 1 of 1 CRSYSTEMS INSPECTION RECORD Retain a copy with permit ICON- 60/1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 /'LGya20ZN31-3670 + Permit Inspection Request Line (206) 438-9350 .I..�I`' a._ Project K T 1 Type of Inspect oit`�`''"`' �'` /11.Reh Ati4. ----- Address: 5 z< 5 kilAA co /o/ Date Called: Special Instructions: Date Wanted: 7 —2Z -1 a.m. p.m. Requester: Phone No: xiApproved per applicable codes. Corrections required prior to approval. COMMENTS: c-o" AO- r Nip Inspector: Date: �z•(—/- REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit. INSPECTION NO. PERMIT NO. q-oz-fcr CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Ptak p(rfticv„, ttzt Projtettox Type of Inspection: rtf-ectt. PrkCqi Address: 31/ 7.5 $0 t ( fC fillff° ( Date Called: Special Instructions: Ai ' - Date yed.5a.m. Want .7 _ a_ p.m. Requester: 7eS-SI.C., e6)) (Pktorit, I A Phone No: 7O6 7S6- 75" 7- 43 I.:Approved per applicable codes. Corrections required prior to approval. COMMENTS: crt,telleei inspectoKe Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:1Q p. Type of In= -- ...-- Addmss: 2 _ 3 3-1--. (2.....-, cl--- I II,, -)t Date Called: ,---, Special Instructions: / tO f eTt) Date Wanted: ...s...... Ci '.. f •S tr i ...a.,11S. p.m. 'Requester: Phone No: .f) 1 b/k Approved per applicable codes. Corrections required prior to approval. COMMENTS: 4, Nje_e_. smoice S 1T ) a/Li A a, t-r Mai/ 5c.V\e4 u1.() I. Instor- ° Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER /5-F--1/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT ma Ggi-( 206-575-4407 Project: cvtf-? Type of Inspection: A Address: Suite #: 337 S S . 11tp,"` . to i Contac Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Add /-a4c,f Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: i "Ay i `� Date: 7/at 1t r Hrs.: / 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 FILE COPY P?rmit No. Carrier United Technologies SUBMITTAL Project Gateway North Date Tuesday, November 25, 2014 MI'*O'9 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 12 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 0 2014 PERMIT CENTER 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM 6T GasEle-460v Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.39m Page 2 of 10 Unit Report For 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM Unit Parameters Unit Model* 48TCDA07A2A6-0A0A0 Unit Size. 07 (6 Tons) Volts -Phase -Hertz* 460-3-60 Heating Type. Gas Duct Cfg• Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size. 1/2 Condensate Drain Line Size. 3/4 Return Air Filter Type* Throwaway Return Air Filter Quantity. 4 Return Air Filter Size. 16 x 16 x 2 Unit Configuration Medium Static Option Al/Cu - Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) *** Unit Length* 6' 2.375" Unit Width. 3' 8" Unit Height* 3' 5.375" *** Total Operating Weight* 712 lb *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA07A2A6-0A0A0 Rooftop Unit 1 Base Unit Medium Static Option None None Accessories CRECOMZR020A02 Standard Leak Vertical EconoMi$er IV with solid-state controller 1 Packaged Rooftop Builder 1.39m Page 3 of 10 Certified Drawing for 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM NOTESI 1. DIMENSIONS ARE IN INCHES DINENSIONS IN I 1 ARE IN NILLINETEGS. 2. CENTER OF GRAVITY 3. DIRECTION OF AIR FLOW FILTER ACCESS PANEL (TOOL -LESS) • INDOOR COIL ACCESS PANEL 3-3/4 (951 46 3/4 11181) COMP. ACCESS PANEL BACK OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET LEFT UNIT 48TC-A04 33 3/8 [8411 18 5/8 [4121 48TC-A05 33 3/8 [841] 14 7/8 [3711 48TC-A06 33 3/8 [8471 14 7/8 [311) 48TC-A07 41 3/8 [10511 14 7/8 [3771 CONDENSER COIL 2-5/8 [671 TIP CURB WIDTH 44 4-5/8 1118) LECTR(CAL DISCONNECT LOCATION 19.1/2 14941 32 1/4 —' 1818] 18-1/0 1 i } [4591 16-1/8 14-1/4 12-114 [all) [363] 13121 1 + I I OPTIONAL FACTORY INSTALLED DISCONNECT SEE TNRU THE BASE CHART 33 3/8 (8481 C UNITED P.o. 003 au TECHNOLOGIES S1PN0NSF. NT CARRIER ISRn ANDS 00[DM[NT IS TNC IIOIE31l 01 CAPNIFE [M100)TNT AND IS CFSINF[NO UNB T0F n0000 C0ID1 TI1N LINT THE ioi101AT ❑[L NOT 6[ DISCLOSED M WIN NITIIOuI CAINI [1 Wouna'3 wm[N coNs[rt. 500NISSOT IX TPEN[ OPINIEOS I 0AEUEEONS DD[s NDl ainlUTE PART PErtuN 2 a I11ANE( IX CpINAtI. ECONOMIZER HOOD (OPTIONAL) 16 [4061 �T 2S-S/8 [6521 RETURN AIR 10-T/8 12171 E ALT. CONDENSATE DRAIN OPENING IN BASEPAN 17-3/4 [4511 SUPPLY AIR 6-1/4 1571 25 16361 HANDLE 30 1/8 [7641 4 [100] 14 3/8 118881 ---- 31 1/A 17931 i LUE HOOD TOP 8-3/13 [2131 1 3-3/8 12-1/5 [851 13071 18-1/2 —� [4101 RETURN AIR 11-3/8 CONNECTION SIZES A 1 3/8' (351 DIA FIELD POWER SUPPLY HOLE B 2' 150) DIA POWER SUPPLY KNOCKOUT C 1 3/4' 151) DIA GAUGE ACCESS PLUG D 1/8' 1221 DIA FIELD CONTROL WIRING HOLE L 3/4'-14 NPT CONDENSATE DRAIN F 1/2.-14 NPT GAS CONNECTION 6 2 1/2 ' C641 DIA POWER SUPPLY KNOCK -OUT TNRU-THE-BA E CHART THESE HOLES REOUIRED FOR USE CRBTNPWROO1A01, 003A01 THREADED WIRE REO'D HOLE CONDUIT SIZE USE SIZES INAE.) W 1/Z' ACC. 7/8' 122.2] A 1/2' 24V 7/8' 122.2] Y . 3/4' 1001.001) POWER 1 1/8' [28.4] 2.. (0031 1/2' OPT GAS 1 3/16' [30.01 FOR 'TNRU-THE-BASEPAN' FACTORY OPTION, FITTINGS FOR ONLY N,Y. 8 2 ARE PROVIDED SELECT EITHER 3/4' OR 1/2' FOR POWER. DEPENDING ON WIRE SIZE A (001) PROVIDES 3/4' OPT TNRU CURB FLANGE 6 FITTING. FRONT SUPPLY AIR RETURN RIGHT AIR 1-1(4 OUTSIDE AIR 441. 21-1/4 15391 BAROMETRIC RELIEF FLOW SHEET 1 OF DAn 11-24-08 0U1RCEDt3 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 NET 5.0 Packaged Rooftop Builder 1.39m Page 4 of 10 DATE: 1 / 07 SUBMITTED TO COMPANY: DRAWN BY. JOB NAME EQUIPMENT: NOTES' FEATURES: • Gear driven dampers eliminate slippage associated with stan- dard linkage. • Designed specifically for down discharge applications. Easy to install. Easy to service. • Lower static pressure loss through economizer dampers. • Greater barometric relief capabilities. • Factory assembled rainhood with aluminum filters in both out- side air and relief hoods. • Uses filter access door shipped with HVAC unit. • Rainhoods are sloped for water run-off. • Hardware loth over relief damper. Down Discharge Economizer with 100% Relief Capability for Carrier 48/50TC A/B04-A/B07; 50TCQ A04-A07; 48/50HC A04-A06; 48/50TF,TM,HJ,TFQ 004-007; 48/50HE 003-006 Units 025 0.2 0.15 O.1 0➢5 0 0688-0101 Static Pressure Loss Through Economizer Return Alr Outll de Alr 0 S00 tom 1500 2000 Airflow (cfrry 2500 3000 ECONOMIZER PART NO.S 0688-0101-00920 Economizer w/ no controls 0688-0101-9J920 Economizerw/fixed dry bulb controls ----f— 0688-0101-54920 Economizer WI modulating enthalpy controls 0688-0101-9A920 Economizer w/ modulating adjustable dry bulb controls Economizer motor and harness Gear driven dampers 19 1/4" Weight = 631bs Sloped Economizer includes Honeywell W7212 controller capable of CO2, JJ Outside demand control and power air exhaust control. Rainhood ships fully assembled Part Number: 0688-0101 3om 2503 31 v20m 3 :E 1503 tom SIB 0 0688-0101 Barometric Relief O 0.05 Access door shipped with HVAC unit Aluminum water en- trainment filters Relief air 0.1 0.15 0.2 0.25 Static Pressure (inw.g.J Drive gear attached to the motor Side View 03 THIS DOCUMENT IS THE PROPERTY OF MICRO METL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICRO METL'S WRITTEN CONSENT. MICROMETL CORPORATION • 3035 N. SHADELAND AVENUE, SUITE 300 • INDIANAPOLIS. IN. 46226 • 1-800-662-4822 ••• MICROMETL WEST • 202 SOUTH 18TH ST. - SPARKS, NV 89431 • 1-800-884-4662 Certified Drawing for 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM / B G\\ Service Clearance ,• toss, LOCATION DIMENSION CONDITION A 48-In (1219 mm) • Unit disconnect is mounted en panel 18-in (457 mm) • No disconnect, convenience outlet option • Recommended service clearance 12-in (305 mmj • Minimum clearance 8 42-in (1067 mm) •Surface behind servicer is grounded (e.g.. metal, masonry wall) 36-in (914 mm) •Surface behind servicer is electrically non-conductive (e.g., wood, fiberglass) Special •Check for sources of flue products within 10- ft. of unit fresh air intake hood C 36-in (914 mm) • Side condensate drain is used 18-in (457 mm) • Minimum clearance D 43-in (1219 mm) • No flue discharge accessory installed, surface Is combustible material 42-in (1067 mm) • Surface behind servicer is grounded (e.g., metal, masonry wall, another unit) 36-in (914 mm) • Surface behind servicer Is electrically non-conductive (e.g., wood, fiberglass) Special • Check for adjacent units or building fresh air intakes within 10- ft. of this unit's flue outlet NOTE: Unit not designed to have overhead obstruction. Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Packaged Rooftop Builder 1.39m Page 6 of 10 Certified Drawing for 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM 0117 STD. UNIT WEIGHT CORNER WEIGHT IA) CORNER WEIGHT 181 CORNER WEIGHT IC) CORNER WEIGHT (0) C.G. NEI6HT LBS. KG. LBS. KG. LBS. KG. LBS. KG. LBS. KG. K T Z /81C-404 483 219 111 50 125 57 131 59 116 53 39 19911 23 [5841 16 3/8 14161 481C-805 537 244 124 56 139 63 145 66 129 59 39 19911 23 [5841 17 14321 481C-806 569 258 131 59 1/1 61 154 70 131 62 39 19911 23 [5841 17 1/4 14381 /87C-407 652 296 150 68 169 16 176 80 157 71 39 19911 23 15841 20 1/8 [5111 CORNER A TOP OO I 1 : 00 FRONT UNITED P.O. POI TWOS TECHNOLOGIES ...HE. 1I CARRIER 13111 THIS MOMENT IS Inc PIUPE1lY Or CAIIIEI C6R101AT101 C0t3 1O3 EW)[1t0 O3(EPHEO3 colrounaa 'HITTER 80x3(1r. roBS[100 10W)I 0i1XOTUHT ACT A111PEI [1 S 0CN 01 T1[SE OPA1116S 10 18CUEE1S 0oca iroluiiiieici aPra�anP�wxAxcE oN CORNER B CORNER C SNIFF 2 OF 2 OAR 11-24-08 VIERCHES 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 5.0 Packaged Rooftop Builder 1.39m Page 5 of 10 Performance Summary For 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM Part Number:48TCDA07A2A6-0A0A0 ARI EER. 11.00 IEER. 11.2 Base Unit Dimensions Unit Length* 74.4 in Unit Width. 44.0 in Unit Height 41.4 in Operating Weight Base Unit Weight 652 lb Medium Static Option. 10 lb Accessories Standard Leak Vertical EconoMi$er IV with solid-state controller 50 lb Total Operating Weight 712 lb Unit Unit Voltage -Phase -Hertz* 460-3-60 Air Discharge' Vertical Fan Drive Type. Belt Actual Airflow. 2400 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy• 31.44 BTU/lb Evaporator Leaving Air DB. 57.6 F Evaporator Leaving Air WB. 57.1 F Evaporator Leaving Air Enthalpy• 24.47 BTU/Ib Gross Cooling Capacity' 75.21 MBH Gross Sensible Capacity' 58.11 MBH Compressor Power Input' 5.11 kW Coil Bypass Factor. 0.084 Heating Performance Heating Airflow. 2400 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 92.8 F Gas Input Capacity* 72.0 MBH Gas Heating Capacity' 59.00 MBH Temperature Rise. 22.8 F Supply Fan External Static Pressure' 0.60 in wg Options / Accessories Static Pressure Economizer 0.17 in wg Total External Static' 0.77 in wg Fan RPM' 1453 Fan Power 1.97 BHP NOTE' Selected IFM RPM Range: 1173 - 1518 Electrical Data Voltage Range' 414 - 506 Compressor #1 RLA. 9.7 Compressor #1 LRA- 62 Indoor Fan Motor Type. MED Indoor Fan Motor FLA. 4.2 Packaged Rooftop Builder 1.39m Page 7 of 10 Performance Summary For 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM Combustion Fan Motor FLA (ea) 0.25 Power Supply MCA. 18 Power Supply MOCP (Fuse or HACR). 25 Min. Unit Disconnect FLA. 17 Min. Unit Disconnect LRA. 100 Electrical Convenience Outlet None Outdoor Fan [Qty / FLA (ea)]. 1 / 0.8 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 89.8 88.6 88.8 125 Hz 85.6 82.5 81.8 250 Hz 80.1 70.7 76.9 500 Hz 75.5 66.8 74.4 1000 Hz 71.9 66.0 73.3 2000 Hz 66.4 60.6 69.8 4000 Hz 68.2 56.7 66.3 8000 Hz 64.3 50.0 62.7 A -Weighted 78.7 72.1 78.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 88.8 81.8 76.9 74.4 73.3 69.8 66.3 62.7 90.1 Lw B 62.6 65.7 68.3 71.2 73.3 71.0 67.3 61.6 78.2 LwA C 56.4 49.4 44.5 42.0 40.9 37.4 33.9 30.3 57.7 Lp D 30.2 33.3 35.9 38.8 40.9 38.6 34.9 29.2 45.8 LpA Legend Packaged Rooftop Builder 1.39m Page 8 of 10 Performance Summary For 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM A Sound Power Levels at Unit's Acoustic Center, Lw B A -Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve 18 16 04 02 L300RPM 1.008FP • co 07 03 06 09 12 15 18 21 Articw(CFM-thousands) RPM=1453 BHP=1.97 MaximumRPM=1585 MaximumBHP=3.70 Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion, SC -System Curve RP -Rated Point \,1900RPM .y150BHP.`.. 24 27 210204v1 - 30 5.00B• - 3.70BHP\, 3.00BHP I 1. 33 Packaged Rooftop Builder 1.39m Page 9 of 10 Unit Feature Sheet for 6T GasEle-460v Project: Gateway North Prepared By: 11/25/2014 09:47AM WeatherMaker` — 48TC PACKAGED ROOFTOP GAS HEATIN&ELECTRIC COOLING UNITS 3. 4, 5, 6, 7.5, 8.5, 10,12.5.15 TON S Optional Louvered Hail Guard She ,ri ISHRA.E [ V1.1w;; COMPLIANT WEATHERMAKER SERIES Veatherl'A alter (48TC) units are one-piece gas heating. electric cooling units that are pre -wired and charged with Puron 'P.-41u': refrigerant. They are factory tested in both heating and cooling modes. and rated in accordance with AHP.I Standards 210..24cI O4-06 sizes) and 340i360 (07-16 sizes). •.h'eatherMaker units are designed in accordance Mth UL Standard 1995, and listed by the Underwriters' Laboratories. Approved and certifiedby, US Certified to ISO 9001 STANDARD FEATURE S INCLUDE: • P''JOn n-:1051.rc refr.ggr3'1i • S1-R4E 93.1 enen]y conDlent • Scrod T•oresoora wan 'ntem9'i-ne ovarood o'otecton • S.na,ealo e,0olina oa0a,'ry,ontro' on 04-12 modese • ',.a-siege,]ot:ng CSDaaty,oniro, on 05-15 mods a • SEEFra LID to 13:3. EER a J0 to 11.1 and IEER'a u0 to 11.o • .4,u1'oin, refr;gerantrneier;ng .;stem • ExoitlEVE non-,Drrosive',omoasit=_ 0:09:ien33le Den accordance Wan 51-1005 Standard 52, s.oana des:211. s:5e orcenlero ror • Stand5'd soo'ng 005r3t.,3n J0 to 115'; ;GS'O; and1y.•.'r1 to :3'r, • down t]25'F,^ :::x^nv:nte"stenkti. • =re -dented exte,]'03ne. and Dnrer-::oa!d-ols-,' D3 n-;-lasted t0 500no.?s3') ;Dray oratesvon - -- - • -o1iy maxis ted,=_onat • Ex: Js =_ l C- so.d ;:ate :oniro. fo' on-o]a-11 ag•'o;. _:. *n LE" e,o-coda dos-gnot:on0J11e':]n1'Ji or: and energy� aevng' door fa_n ^1013•-zia'3'v • Lon,: i- x nodal. tnet ^,et: COO-ty L'00 )e Rnl • IndJ:ed draft -ilea nast :D,Ouivon ic3'.7'n • P.edundsnl gel•:3..:05 WOO .101131a- tsgea of .nee: no 1 • o.'. DresaJ'e 5n.d n:J5 n D'esJre _.,'Sri - MAINTENANCE FEATURES: • 03nea:.1n e35y] - 11,11,a2 • Innoyet,e n: ] - : .05 on J"1,: a .sne 5 • n n1 so,, .1 ?a•oT]]-a f3 •- --..c. • _n: ._ evadorel013n mold e 1 oJ'ev:o,dn_1o,s • te"nna' o03r1 safety:'':JR :'0J0 ea -no -ding and .morf.ed .oniro Dos a -anger -yen', • Ex:Js^:e n3 =- ao',d-state :11.1.1'0-fJ' 3n-003'1 d agn1st0 10.00 LE.. err0rg0de e;-anat'Dn. 0Jr!rer000I13 :0g , 2,13 ene'gy a3.ng:nd]r fan "V 7'].' de 3 y". INSTALLATION FEATURES: • 7nrJ-1ne-03110m00'001S0LN:s030'tly • S.na_-e oantasaand eecta:00100010na • rU' Oenme:er Dese rbd ,r.:n DJ.a.n ad=0101; and fOr.- 5 0l' • Fe:.onsen:d!s from •ve ' to n0,001t3 3"f ow for snail ^l]Unt nil. ;:1.5 s,e models reaU+'3 'read-na.5.ed 2JDOiy'1J2.1 •33,ar. STANDARD WARRANTY: • 10-yssr heal cool ros'_ 15-,,aer s1.3m'eaa ;leer ]ot:0n • 5.1e5'c0T0'eaa0• • 1-yearda^15 • 3-year Ds Dn Novafon Condenae'AS • M3nyooton3!uo}3des 5;503u5;'a01a Die OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • ?'s'0SrLin:,'° end!'L. moan lolut- Pronto DOC • SCusoly and 00IJ^1 4r• 7r,3;w; C515:10?. h:oh ;t51-': '00l0? • Lo ova ed sondenzer - .IJ3 di • E:on]m_:,d=annest sod c0nvencnie oJt51o010ns • S15 n'ese Sias' nest ex,nangaroot ]n • t-or-os on -es slant :0: ,001,ng. • !-.J m.1-1,1'ze' 3da01,.e 1enJn-,d:f:51Jn 3y3te^.3•F3 30t ]n 3- 'o.33a ..., -PF .Dn 13 l,'-,D 21e ! ." .. , ;' n:'J9e • F]'a :'J"r0'S10 'Et of 501.Jn's ends. "ea"o ea'era- 10 Ina .-D1J:1 Data Packaged Rooftop Builder 1.39m Page 10 of 10 FILE COPY P 'rr !t No. 0 WAS11 ,<Q' ZG 1 4) T18959. zcss/ONA L EN� STRUCTURAL CALCULATIONS Gateway North RTU 3225 South 116th Street Tukwila, Washington DECEMBER 1, 2014 PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington More Engineering Group REVIEWED FOR CODE COMPLIANCE APPROVED DEC 12 2014 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 10 2014 PERMIT CENTER GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2012 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT 827 POUNDS EARTHQUAKE SDS = 0.961 SITE CLASS D to E WIND 85 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 8. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 9. CONNECT THE NEW UNITS TO THE METAL CURB WITH A MINIMUM OF (2) #10 SHEET METAL SCREWS ON EACH SIDE OF THE UNIT. PLACE ONE SCREW AT 6" TO 8" FROM EACH CORNER OF THE UNIT. 10. AS AN OPTION FOR ANCHORAGE OF THE UNIT, CONNECT THE NEW UNIT TO THE METAL CURB WITH AN 18 GAGE x 2-1/2" WIDE GALVANIZED METAL STRAP WITH (2) #10 SHEET METAL SCREWS INTO BOTH THE UNIT AND CURB IN EACH CORNER OF THE UNIT AS SHOWN ON THE ATTACHED PLAN. PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop mechanical unit with a new unit. LOADS: LIVE 25 PSF DEAD Roofing and re -roof 4.0 1/2" Plywood sheathing 1.5 2x6 @ 24" o.c. 1.1 4x14 @ 8' o.c. 1.5 Insulation 1.0 MEP 2.0 Ceiling & Lights 2.9 Total Dead 14 DEAD + LIVE WIND 85 mph, Exposure B SEISMIC 39 PSF Latitude 47.498 Longitude -122.291 Site Class D to E WA DNR SDs (D) = 1.011 SDs (E) = 0.910 SDs = 0.961 EQUIPMENT Existing New Unit 649 712 Existing Curb 115 115 Total 764 827 Dimensions 74"x44"x53" high Moore Engineering Group PROJECT: GATEWAY NORTH RTU ENGR: KWM DATE: 12/ 1 / 14 SCALE: SHEET ' Design Maps Summary Report Page 1 of 2 MUSES Design Maps Summary Report User -Specified Input Report Title Gateway North RTU Thu November 27. 2014 17:17:45 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 200B) Site Coordinates 47.498°N, 122.291°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III Vashon il r'1 allquest 15mi 5000in USGS-Provided Output Ss = 1.517 g = 0.570 g is �. White; cERter '+;' A a TFawcastle Tukwila ,BUtiert_ 1 o r� \ 4 SeaTac SMs= 1.517 g SMy = 0.854 g @2( 4f Sos = 1.011 g SDI = 0.570 g 0 'l `j" : MERICA East it( _ (#ighiar MapQuest For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. NICER Response Spectrum 1.7e 1.20 1.44 1.2£ 1.12 • 0. 02 N 0.00 0.64 0.4£ 0.32 0.15 0.00 0.00 0.20 0.40 0.20 0.00 1.00 1.20 1.40 1.60 1.00 Period, T (sec) 2.00 1.10 0.99 0.22 0.77 Ci 0.66 • 0.55 cn 0.44 0.33 0.22 0.11 0.00 0.00 Design Response Spectrum 0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.80 Period, T (sec) 2.00 http://ehp 1-earthquake.cr.usgs.gov/desigmnaps/us/summary.php?template=minimal&latit... 11 /27/2014 .Design Maps Summary Report Page 1 of 2 USGS Design Maps Summary Report User -Specified Input Report Title Gateway North RTU Thu November 37, 2014 17:18:30 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.498°N, 122.291°W Site Soil Classification Site Class E - "Soft Clay Soil" Vachon mapquest Risk Category I/II/III s000m smi USGS-Provided Output Ss = 1.517 g Si = 0.570 g Sms = 1.365 g SM1 = 1.367 g t99 Newcastle 0 rirf4 Y-90r3. East R( . , Highlac Tukwila 0 I I-1 'It A fv1 E Pi 1 C if €.20,4r @ftlatauest S., = 0.910 g 501 = 0.911 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. MCER Response Spectrum 1.10 - 1. 40 - 1.00 - 11 VI ttl 0.84 0.70 T:11 O.C.0 - o to o.so - \\N.,..............„.............. 1.12 0.O0 - 0.99 0.70 0..5r.; 0.40 0.42 0.20 - 0.14. 0.10 - O. 00 i I I 1 1 1 I i i I 0.00 0.00 0.20 0.40 ace O. SO 1.00 1.20 1.40 1.60 1.00 2.00 0.00 0.20 0.40 0.0 ci.eo 1.00 1.20 1.40 1.60 1. SO 2.00 Period, T (sec) Period, T (sec) Design Response Spectrum http://ehp4-earthquake.cr.usgs.govidesignmaps/us/summary.php?template=minimal&latit... 11/27/2014 ) 1'2! ' / t I 0 s)cfCir e-' -I! C- , t . Pe. 17Y---,1 l<- F:-1Ffl ')K1I-T• r-t Moore Engineering Group ) PROJECT: . - A ENGR: DATE: /1 /1,4 SCALE: 1 SHEET (Ni C rss (in ••• ..4.-.., P N-4•4 - - 0 '\...1 vs ,, XI- ,_ "#`1' \ / , • tk •0 — .1. X 'co [ f• . x 1 '1'4 ''' 3 \+s ° •4 '.- N M i , , • a- 1 vA. Physical data BASE UNIT 48 DJE004 DJD/DJE005 DJD/DJE006 DJD/DJE007 NOMINAL CAPACITY 3 4 5 6 OPERATING WEIGHT (Ib) Unit 530 540 560 615 With Economizer 564 574 594 649 Roof Curb 115 115 115 115 COMPRESSOR Hermetic Quantity 1 1 1 1 Oil (oz) 55 55 70 70 REFRIGERANT TYPE R-22 Operating Charge (Ib-oz) 3-13 5-8 6-11 9-0 CONDENSER FAN Propeller Quantity...Diameter (In.) 1..26 1 .26 1.. 26 1 . 26 Nominal Cfm 3500 4100 4100 3800 Motor Hp...Rpm 'S. 850 Vs 850 1 850 1 850 CONDENSER COIL Enhanced Copper Tubes, Aluminum Lanced Fin Rows...Fins/In. 1...17 1.17 1...17 2.. 17 Total Face, Area (sq ft) 7.78 12 25 12.25 12 25 EVAPORATOR FAN Centrifugal Size(In.) 10x10 10x10 10x10 10x10 Type Drive Std Direct Direct Direct Belt Alt Direct Bell Bell Belt Nominal Cfm 1200 1600 2000 2400 Horsepower per National Std 1 v2 % 1 0 Electrical Code (NEC)' Aft +h =ya 1.0 1.6 Maximum Continuous bhp Std 38 87 1 29 1 70 Alt 78 1.30 1.70 2.40 Motor Frame Std 48 48 48 56 Alt 48 56 56 56 Nominal Rpm High/Low SW 860/845 1080/970 1080/1040 — Alt 1080/970 — — — Fan Rpm Range Std — — 875-1190 Alt — 800-1130 875-1190 1070-1460 Motor Bearing Type Ball Ball Ball Ball Maximum Fan Rpm 2100 2100 2100 2100 Motor Pulley Pitch Diameter Std — 2.8-3.8 A/B (In.) Alt — 2 4.3 4 2 8-3 8 2.8-3.8 Fan Pulley Pitch Diameter (in.) Std — — 5 2 — 5 5 Belt — Type...Length (In.) Std — — ° 5 A4 40 Alt — A 40 A 40 A..39 Pulley Center Line Distance (In.) Std — 14 7-15.5 Alt — 14 7.15.5 147-15.5 14 7-15 5 Speed Change Per Full Turn of Std — — — 63 Movable Pulley Flange (rpm) Alt Movable Pulley Maximum Full SW — — 66 63 79 5 Turns from Closed Position Alt — 5 5 5 Factory Setting — Full Turns Open Std Alt — — — 3 — 3 3 Factory Speed Setting (rpm) Std — 1000 All — 930 1000 1230 Fan Shaft Diameter at Pulley (In.) — % % s EVAPORATOR COIL Enhanced Copper Tubes, Aluminum Double WavyFin Rows...Fins/in. 2. 15 2...15 3.. 15 4.. 15 Total Face Area (sq ft) 4 17 5.5 5 5 5 5 FURNACE SECTION Burner Orifice Diameter (In. _.drill size)t Natural Gas — Std 113...33 .113 33 113...33 113.. 33 Liquid Propane — Alt 089..43 080 43 089,. 43 089 43 Thermostat Heat Anticipator Setting (amps) 208/230/460 v 1.0 1 0 1 0 1 0 Gas Input 74,000 74,000/115,00 74,000/115,000 74,000/115,000 Efficiency (Steady State) (%) 80 80 80 80 Temperature Rise Range Manifold Pressure (in. wg) 25-55 25-55/35-65 25-55/35-65 25-55/35-85 Natural Gas — Std 3 5 3 5 3.5 3 5 Liquid Propane — Alt 3.5 3.5 3.5 3.5 Maximum Static Pressure (In. wg) 75 75 75 75 Field Gas Connection Size (In.) 5 : 5 5 5 HIGH-PRESSURE SWITCH (psig) Cutout 428 Reset (Auto.) 320 LOSS-OF-CHARGE/LOW-PRESSURE SWITCH (Liquid Line) (psig) Cutout 7 ± 3 Reset (Auto.) 22 ± 5 OUTSIDE -AIR INLET SCREENS Quantity...Size (In.) Cleanable 1..20x24x1 RETURN -AIR FILTERS Disposable Ouantlty...Size (in.) 2 16 x 25 x 2 LEGEND Bhp — Brake Horsepower 'Used to determine wire sizing per NEC t48DJD005-07 and 48DJE004 (74,000 Btuh) units have 2 burners 481:JE005-007 (115.000 Biuh) units have 3 burners. • • Base unit dimensions — 48DJ004-007 I440) 0,117 19021 0'-7 1/4' [1841 0'-10 13/1.' [2751 RETURN - AIR OPENING HORI- ZONTAL 7' [1781 0'-4 1/16' [103) FILTER ACCES5 PANEL (DISPOSABLE FILTERS) 2'-1 I1/16' C653) ACCESSORY HOOD FILTER 1' 11 1/4' OUTSIDE AIR 0'-5 3/4'� '-1 1S/1•' 0'-5 11/16' (146) . . C659) [1441 SUPPLY AIR RETURN AIR E STD CONDENSATE DRAIN (INTERNALLY NOTES: R I GHT SIDE TRAPPED) 1 Dimensions in j I are in millimeters, 2‘13 Center of Gravity. 3 'V///j Direction of airflow 4 Ductwork to be attached to accessory roof curb only 5 Minimum clearance (local codes orjuris- diction may prevail): a Between unit, flue side and combus- tible surfaces, 36 inches b Bottom to combustible surfaces (when not using curb), 14 Inches c Condenser coil, for proper airflow, 36- in. one side, 12 In the other The side getting the greater clearance Is optional d Overhead, 60 In. to assure proper con- denser Ian operation e Between units, control box side, 42 inches f Between unit and ungrounded sur- faces, control box side, 36 inches g Between unit and block or concrete walls and other grounded surfaces, control box side, 42 Inches h Horizontal supply and return end, 0 inches 8 With the exception of the clearance for the condenser cog and combustion side, as stated in notes 5a, b and c, a remov able fence or barricade requires no clearance Connection Sixes A 13s" Die 1351 Field Power Supply Hole a 2" Be 1511 Power Supply Knockout C 134" Dia 144) Charging -Pon Hole D Y6' Dia 122j Field Control Wiring Hole E 34'•14 !VT Condensate Drain F WI4 NPT Gas Connection G 2 W' Dia 1641 Power Supply Knockout ELECTRICAL t 0'-7 3/8 DISCONNECT I1e71 — LOCATION 2'-9 5/16' [8 7) 807TLRi OF UNIT 0'-4 9/16".1 I TYP 3' S 3/16' I1161 ej tF (10461 0'-2 9/16' [657 LEFT SIDE CORNER 'A'� UNIT STD UNIT WEIGHT ECONOMIZER WEIGHT CORNER WE GHT (A) CORNER WE GHT (B) Lb Kg Lb Kg Lb Kg Lb Kg 48DJE004 630 240 34 15 4 104 47.2 97 44 0 48DJE/DJ0006 540 245 34 15.4 106 48 1 98 44 5 48DJE/DJ0006 560 254 34 15 4 110 48 9 102 46 3 48DJE/DJDO07 615 279 34 15 4 120 54 4 112 50 8 UNIT CORNER WEIGHT (C) CORNER WE GRIT (D) "H" Lb Kg Lb Kg Ft•In. mm 48DJE004 159 72 1 171 77.6 3.11/4 947 48DJE/DJDO05 162 73 5 174 78 9 1.21/4 362 48DJE/OJDO08 168 76 2 180 81 6 1.21/4 362 480JE/DJ0007 185 83 9 198 89.8 1.21/4 362 T-015116' tIDell - FILTER/ECONOMIZER ACCESS PANEL rCONDENSER COIL OUTSIDE AIR ,__ 2' -0 15/16".____. [633) 0'-4 1/2' OPTIONAL ECONDMI7ER HOOD 1'-4 3/B' [416) Imo --CORNER '8' 3 -9' (11443 I' 5' [43?) CORNER 'D'--"r"." 1/ 0'-2 15/16'-" 175 0'-4 5/0'- (I18) EVAPORATOR COIL rI (652) RETURNS IRCOPENING L ALT. CONDENSATE )RAIN OPENING IN BASEPAN TM0'-3 3/16' • [81) 1 RETURN AIR 0'-10 15/16' ' 05lO [2781 rr I � (13773/8' ( SUPPLY -AIR OPEN IN6 VERTICAL I `0'-? 9/16' C651 I'-5 3/4' (4511 j 0'-5 7/16' C136) -4 9/16' [725 5)-0 0'-3 1/16' 6'-I I1/16' fie)7B) [1972) •0'-(973 3 13/16' B FLUE HOOD 5/16' [4151 0'-6 5/8' (1691 2'-11 I/T i [9G2) FRONT I3067 SUPPLY AIR 0'0'-3CORNER'C' �CO1) 1'-5 CONTROL 60X/ CORPRE550R/ BURNER ACCESS PANEL 0'-4 3/16' [IO 71 1 7/16". (4431 IN000A-FAN MOTOR 6 BLOWER ACCESS PANEL U' f :%OO I 1 1 /4 1 QOO, 5 3/8' i CI461 7/t8' ORK TRUCK SLOTS / 0'-e [2t41 0'-2 I/4'0IA [571 (TYP 8 PLACES) FRONT 0'-0 3/6' n07 CN� Project: Gateway North Prepared By: Performance Summary For 6T GasE[e-4€Ov 11/25/2014 09:47AM Part Number:48TCDA07A2A6-0AOAO ARI EER:.. 11.00 IEER ....11.2 Base Unit Dimensions Unit Length. _ 74.4 in Unit Width: .__...._.........._........._........._ _..._..... 44.0 in UnitHeigh:.._.._._........._..._....._....----....._.._.........._........_.......__._............_.....----._.................._..............._....._..._............_......._.....4t:4 in Operating Weight Base Unit Weight._...._ ................._ 652 lb Medium Static Option. 10 lb Accessories Standard Leak Vertical EconoMi$er IV with solid-state controller_ 50 lb Total Operating Weight. 712 lb Unit UnitVoltage-Phase-Hertz:._............................._...............-....._...._................._.._......................._...-....-..................._................460-3-60 Air Discharge:. Vertical Fan Drive Type. . .Belt Actual Airflow' 2400 CFM Site Altitude:....... ..... _______ ........... 0 ft Cooling Performance Condenser Entering Air DB• 95.0 F Evaporator Entering Air DB: 80.0 •F Evaporator Entering Air WB:.._ 67.0 F Entering Air Enthalpy:._...._......._..... ._........... .................._.._31.44 BTU/lb EvaporatorLeaving Air DB:.._......................................._................_..._................._......._..................._......................................_57.6 F EvaporatorLeaving Air WB:..... ...-.... .......__................... _........... ..........:.......... ......._.................. -............. .......... ..... ................_67.1 F Evaporator Leaving Air Enthalpy• 24.47 BTU/lb Gross Cooling Capacity 76.21 MBH Gross Sensible Capacity* 58.11 MBH Compressor Power Input:.. . 5.11 kW Coil Bypass Factor:... ....... 0.064 Heating Performance Heating Airflow. 2400 CFM Entering Air Temp:..._.. ............ _ ..... ____ LeavingAir Temp:.._-..--...__.._..._......................_.....__......._..._............_.............._ 92.8 F Gas Input Capacity:.__......._ ........... .._........... ..-....................... 72.0 MBH Gas Heating Capacity. 59.00 MBH Temperature Rise' 22.8 F Supply Fan External Static Pressure: ......... ..... ...... ........ 0.60 in wg Options / Accessories Static Pressure Economizer Total External Static. 0.77 in wg FanRPM :.. ....................._.............._....... 1453 Fan Power .................. . 1.97 BHP NOTE Selected IFM RPM Range: 1173 -1518 ........ ....................... ...._..... .0.17 in wg Electrical Data Voltage Range 414 -506 Compressor #1 RLA:..... .......................... .._ 9.7 Compressor #1 LRA:........................._........._.. .... ............_...._..62 Indoor Fan Motor Type- MEED Indoor Fan Motor FLA• ;',•cicaged Rooftop Buiroer 1.39m Pne 7 of 10 Certified Drawing for 6T GasEle-460a Project: Gateway North Prepared By: 11/25/2014 09:47AM Hill S1D. UNIT REI0H1 CORKER 11EIG111 I0) CORKER ♦E1011'101 CORNER YEI6N7 ICI CORKER WE16HT 01 C.G. HEIGR1 LOS. SG. LS1. KG. 1.61. NO. 16S. 10. E05. NG. 1 1 2 1116-644 4R3 111 111 50 125 SR 131 5R 116 53 39 111)] 23.15543 16 315 14111 4412-613 511 244 124 51 13S 13 145 00 121 51 31 11111 23 (564) 17 14321 401(.111 561 256 131 '6! 147 61 154 70 131 62 39 11111 23 15041 17 114 14361 1110•611 652 211 150 65 161 16 176 80 157 II 31 11111 23 15041 20 110 (5111 10P T[WMO(OGIES 1.1wl. 44 CARRIER 14*3 f+u 1a�.1a ss n1 ..ae.v > ua¢< 1wrm,le. '""...Isn%.81°Ii'.ttt �N04M1101'f Ht111f. IHR4tlt. CORNER 8 CORNER C 1. ri00 ! I i l a, �. : 00E LJ FRONT NMI 2 Of 0.01 11-24-08 ail<IeE. 09-29-08 481C 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48714500993 >JK.O Packaged Rooftop Builder 1.39m Page 5 of 10 I�4 \.\ I L4 , ~ (- c4 (7 57 c Lr��e'ref a 7'4 CL {i L Moore engineering roup PROJECT: _.. 6•ti� f � �i ff, ENGR` DATE: SCALE: SH City of Tukwila Department of Community Development 7/1/2015 JESSE CHUTICH 3202 C STREET NE AUBURN, WA 98002 RE: Permit No. M14-0219 RPI 3325 S 116TH ST STE 101 Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 8/26/2015. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 8/26/2015, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M14-0219 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M14-0219 DATE: 12/10/14 PROJECT NAME: RPI SITE ADDRESS: 3325 S 116 ST X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AT t ,H`1i Li 4/�ijC P---1 / Building Division Fire Prevention Public Works Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 12/11/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 01/08/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 COMFORT MECHANICAL INC Page 1 of 2 0 Washington State Department of Labor & Industries COMFORT MECHANICAL INC Owner or tradesperson JACKSON, SHIRLEY A Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA98002 425-251-9840 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective — expiration 06/01/1999— 04/25/2016 Bond Lexon Ins Co Bond account no. 9815017 $6,000.00 Received by L&I Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Bond history Insurance Continental Western Ins Co Policy no. CWP6015115 $1,000,000.00 Received by L&I Effective date 05/30/2014 06/01/2014 Expiration date https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 12/24/2014