Loading...
HomeMy WebLinkAboutPermit PG14-0035 - BOEING #7-31 - RESTROOMS AND UTILITY ROOMBOEING #7-31 12779 GATEWAY DR PG1 4-0035 City of Tukwila Department of Community Development �2� 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: PLUMBING/GAS PIPING PERMIT 2716000060 Permit Number: PG14-0035 12779 GATEWAY DR S BLDG 6 Issue Date: 4/1/2014 Permit Expires On: 9/28/2014 Project Name: BOEING #7-31 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: EPROPERTY TAX INC DEPT #207 PO BOX 4900 , SCOTTSDALE, WA, 85261 VERNON R HUBER 3702 W VALLEY HWY N, STE 200 , AUBURN, WA, 98001 HUBER'S PLUMBING CO Phone: (206) 510-3069 Phone: (253) 839-7876 3702 WEST VALLEY HWY #2 , AUBURN, WA, 98001 HUBERP*042M2 Expiration Date: 7/17/2014 / 1 / DESCRIPTION OF WORK: DEMO EXISTING PHOTO LAB. IN THE VACANT SPACE ADD NEW MENS RESTROOM & UTILITY ROOM. DEMO EXISTING UTILITY ROOM AND ADD NEW WOMES RESTROOM. Valuation of Work: $21,000.00 Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $363.36 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature wwACJI4A Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name:1�./1 ,7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. 5: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 8004 GROUNDWORK 1900 PLUMBING FINAL 8005 ROUGH -IN PLUMBING CITY OF TUKWL Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hftp://www.TukwilaWA.gov Plumbing/Gas Permit No. & lL-V l.O3S Project No. Date Application Accepted: 3" t O - 19 Date Application Expires: ''' () — (For office use only) PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION lzi77 King Co Assessor's Tax No.: 271600-0050-00 Site Address: 12446. Gateway drive. Suite Number: 7-34 Floor: 1 Tenant Name: Boeing PROPERTY OWNER Name: CBRE Address: 20415 72nd Ave S., Suite 210 City: Tukwila State: wa Zip: CONTACT PERSON — person receiving all project communication Name: Vernon R Huber Address: 3702 West Valley HWY. North #200 City: Auburn State: wa Zip: 98001 Phone: (206) 510-3069 Fax: Email: vrhuber@gmail.com New Tenant: ❑ Yes ..No PLUMBING CONTRACTOR INFORMATION Company Name: Hubers Plumbing Co. Address: 3702 West Valley HWY. North #200 City: Auburn State: wa Zip: 98001 Phone: (206) 510-3069 Fax: Contr Reg No.: HuberP *042M2 Exp Date: 07/14/2014 Tukwila Business License No.: 0993217 Valuation of Project (contractor's bid price): $ 21,000 Scope of Work (please provide detailed information): Demo existing Photo lab . In the vacant space add new Men's restroom& Utility room. Demo existing Utility room and add new Women's restroom. Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water City of tukwila Sewer: Metro H:Wpplications\Form-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 l.docx Revised: August 2011 bb Page 1 of 2 Indicate type of plumbing fixtures and/or gu6 piping outlets being installed and the quantity uelow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Shower, single head trap Sinks f Rain water system - per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory 5 Urinal 1 Water heater and/or vent 1 Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backtlow protections over 5 Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet 4 Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping dr Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain 2 Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each lawn sprinkler system on any one meter including backflow protection devices PERMIT APPLICATION NOTES - Value of Construction - In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review - Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER �TH ��ENT: Signature: Date: 03/10/2014 Print Name: Vernon R Huber Day Telephone: (206) 510-3069 Mailing Address: 3702 west valley hwy. #200 Auburn wa 98001 City State Zip H:Wpplications\Forms-Applications On Line \2011 Applications\Plumbing Permit Application Revised 8.9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ( ACCOUNT QUANTITY I PAID $363.36 PG14-0035 Address: 12779 GATEWAY DR S BLDG 6 Apn: 2716000060 $363.36 PLUMBING $349.38 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $247.00 PLAN CHECK FEE R000.322.103.00.00 $69.88 TECHNOLOGY FEE $13.98 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R1421 R000.322.900.04.00 $13.98 $363.36 Date Paid: Monday, March 10, 2014 Paid By: VERNON R HUBER HUBERS PLUMBING Pay Method: CREDIT CARD 202340 Printed: Monday, March 10, 2014 10:27 AM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 P6 LI- Proje - ` Type of Inspection: Address: V 1 cD C_ _ �� �� Date Called: SEiecial Instructions: ►- Date -W-�a7nted: c 1 — Z f — I a>+m (P.m. Requester: Phone No: SQpproved per applicable codes., Corrections required prior to approval. COMMENTS: 1 sp r:AAALA lib/ E REINSPECTI©N FEE REQUI ED. Prior tdinext inspection, fee mst be d at 6300 Southcenter Blv ., Suite 10d. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Projec t Type of Inspection: L I �13G Q c tali ,iv� Address: 1, 7 7 1 k, Date Called: Special Instructions: / Date Wanted: 5- LD-'IL/ 1.n.. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: / (n IA J Kc i tp*, r 1 , 1 his Prt,'I/G��j p/tErNSPECTION FEE REQUIRED. Prior to (paid at 6300 Southcenter Blvd., Suite 100. Date: next inspection, fee must be Call to schedule reinspection. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 Pro' t: t / 1c6QEtt� 6'4% Type of Jnspection: Rt ci ti -- ii J Address: 1 2--i79 6.) A ►:; aiti'l lYZ. Date Called: Special Instructions: Date Wanted: .- i f .—,— Iq /-a:rn.. ('"m. Requester: Phone No: ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: p Cl l i G 4- i Z6V✓) 8'uct ()DtCl✓e 1 Incpect : Date: EINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paidCat 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 PGi Project: .it Type of Inspection Address- _ Date Called: Special Instructions: Date Wra�ted: / ,aim. Requester. Dduc, Phone No: QApproved per applicable codes. EJ Corrections required prior to approval. COMMENTS: A (G.s'3fj1J1 tJY 1-1L1'T Date: CI— lrs5pettor- jRENS'PECTION FEE REQUI ED. Prior to next inspection, fee must be td/at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. City of Tukwila Department of Community Development March 12, 2014 VERNON R HUBER 3702 WEST VALLEY HWY N, SUITE AUBURN, WA 98001 RE: Correction Letter # 1 PLUMBING/GAS PIPING Permit Application Number PG14-0035 BOEING #7-31 - 12779 GATEWAY DR S Dear VERNON R HUBER, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (BUILDING REVIEW NOTES) 1. Toilet rooms containing two or more water closets or a combination of one water closet and one urinal shall be provided with floor drains. Floor drain trap shall be protected with a trap seal primer. Trap seal primers shall be accessible for maintenance. Show trap primers on the plans for the floor drains with the pipe and sizes specified, typically 1/2" supply line. (UPC 418.3 & 1007.0) Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, -1:0 Bill Rambo Permit Technician File No. PG14-0035 6300 Southcenter Boulevard Suite #100 • Tukwila Washin2ton 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT CCORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0035 DATE: 03/24/14 PROJECT NAME: BOEING #7-34 SITE ADDRESS: 12779 GATEWAY DR S Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: S uilding Division Public Works Fire Prevention Structural n n Planning Division Permit Coordinator n m PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/25/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 04/22/14 Approved with Conditions T Corrections Required Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: PG14-0035 PROJECT NAME: BOEING #7-34 SITE ADDRESS: 12779 GATEWAY DR S X Original Plan Submittal Response to Correction Letter # DATE: 03/10/14 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Cov�rZ Lk Building Division "is N Pub tc Wor s Fire Prevention Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) REVIEWER'S INITIALS: DATE: 03/11/14 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: DUE DATE: 04/08/14 REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire ❑ Ping ❑ PW ❑ Staff Initials: 144 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 03/24/2014 Plan Check/Permit Number: Rat -O&M -- Response to Incomplete Letter # ✓ Response to Correction Letter # 1 Revision # after Permit is Issued ✓ Revision requested by a City Building Inspector or Plans Examiner Project Name: BOEING #7-31 Project Address: 12779 GATEWAY DR S Contact Person: Vern Huber Phone Number: (206) 510-3069 Summary of Revision: Show on floor plan location of existing floor drain and access panel in the photo lab (which will be the new Mens room). Show on floor plan location of existing floor drain and access panel in the Janitor's Closet. (which will be the new womens room). r�r MAR 2 4 aUi . nalltattallft Sheet Number(s): #1 "Cloud" or highlight all areas of revision including date of revis n Received at the City of Tukwila Permit Centerpby: Entered in Permits Plus on 15 Jr""4 t`1 H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 - Revision SubmittaLdoc Revised: May 2011 La King County Department of Natural Resources and Parks Wastewater Treatment Division Non -Residential Sewer Use Certification • To be completed for all new sewer connections, reconnections or change of use of existing connections. • This form does not apply to repairs or replacements of existing sewer connections within five years of disconnect. Please Print or Type Property Street Addre s City State Owner's Name Subdivision Name Lot # Subdiv. # Block # Building Name (if applicable) A)'61)- 00351 For King County Use Only Account # No.,of RCEs Monthly Rate Property Tax ID # Party to be Billed (if different from owner) City or Sewer District Date of Connection Side Sewer Permit # Please report any demolitions of pre-existing building on this property. ( ) Credit for a demolition may be given under some circumstances. Owner's Phone Number (with Area Code) Demolition of pre-existing building? ❑ Yes ❑ No Was building on Sanitary Sewer? ❑ Yes ❑ No Property Contact Phone Number (with Area Code) Owner's Mailing Address Was Sewer connected before 2/1/90? ❑ Yes ❑ No Sewer disconnect date: Type of building demolished? Request to apply demolition credit to multiple buildings? 0 Yes El No A. Fixture Units Fixture Units x Number of Fixtures = Total Fixture Units Kind of Fixture Fixture Units No. of Fixtures Total Fixture Units Public Private Public Private Bathtub and Shower 4 4 Shower, per head 2 2 Dishwasher 2 2 Drinking fountain (each head) 1 .5 Hose bibb (interior) 2.5 2.5 Clotheswasher or laundry tub 4 2 Sink, bar or lavatory 2 1 `( "Sink, Clinic flushing 8 8 Sink, kitchen 3 2 Sink, other (service) 3 1.5 Sink, wash fountain, circle spray 4 3 Urinal, flush valve, 1 GPF 5 2 Urinal, flush valve, >1 GPF 6 2 Urinal, waterless 0 0 Water closet, tank or valve, 1.6 GPF 6 3 Lf Water closet, tank or valve, >1.6 GPF 8 4 Total Fxture Units Residential Customer Equivalent (RCE) 20 fixture units equal 1.0 RCE Total No. of Fixture Units = qc RCE 20 B. Other Wastewater Flow (in addition to Fixture Units identified in Section A) Type of Facility/Process: Estimated Wastewater Discharge: Gallons/days Residential Customer Equivalents (RCE): 187 gallons per day equals 1.0 RCE Total Discharge (gal/day) 187 C. Total Residential Customer Equivalents: (add A & B) A B RCE RCE ,�lirr~;rrr�l3 CITY OF TUX i>k MAR 1 0 201k PERMIT CENTER Pursuant to King County Code 28.84, all sewer customers who establish a new service which uses metropolitan sewage facilities shall be subject to a capacity charge. The amount of the charge is established annually by the King County Council at a rate per month per residential customer or residential customer equivalent for a period of fifteen years. The purpose of the charge is to recover costs of providing sewage treatment capacity for new sewer customers. All future billings can be prepaid at a discounted amount. All future billings can be prepaid at a discounted amount. Questions regarding the capacity charge or this form should be referred to King County's Wastewater Treatment Division at 206-684-1740. I certify that the information given is correct. I understand that the capacity charge levied will be based on this information and any deviation will require resubmission of corrected data for d er+fltfrIion of a revised capacity charge. Signature of Owner/Representative Date Print Name of Owner/Representative 1 r1SR IR.,, 01117\ HUBER'S PLUMBING CO Page 1 of 4 Washington State Department of Labor & Industries HUBER'S PLUMBING CO Owner or tradesperson HUBER, VERNON R JR Principals HUBER, VERNON R JR Doing business as HUBER'S PLUMBING CO WA UBI No. 601 725 669 3702 West Valley Hwy. North #2 AUBURN, WA98001 253-839-7876 KING County Business type Individual Governing persons CANDICE LEE HUBER License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties PLUMBING License no. HUBERP*042M2 Effective — expiration 07/22/1996 — 07/17/2014 Bond American Contractors Indem CO Bond account no. 100194911 Received by L&I 05/11/2012 Insurance State Farm Fire & Cas Co Policy no. 98BTJ4920 Received by L&I 02/27/2014 Savings Active. Meets current requirements. $6,000.00 Effective date 05/06/2012 $1,000,000.00 Effective date 03/30/2014 Expiration date 03/30/2015 No savings accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601725669&LIC=HUBERP* 042M2&SAW= 04/01/2014 WALL SCWEDULE: A. 3 5/8" X 20 GA STEEL STUD AT 24" O.C. (OR MATHC EXISTING ADJACENT FRAMING), TO GYP BD CEILING OR ACOUSTICAL CEILING WHICH EVER IS HIGHER, WITH 5/8" GYP BD EACH SIDE (WATERPROOF INSIDE RESTROOM), SOUND INSULATE B. FUME OUT WITH STEEL STUD X 20 GA AT 24"O.C. TO ACCOMODATE PLUMBING (REMOVE EX. GYP BD BEHIND), 5/8" GWATERPROOF GYP. BD. FURR OUT WALL WITH STEEL STUD TO ACCOMODATE PLUMBING, 5/8" WATER PROOF GYP BD 1 D. PLUMBING WALL- 6" STEEL STUD X 20 GA AT 24" OL., 5/8" GYP BD EACH SIDE "(WATERPROOF IN RESTROOM), SOUND INSULATE pS.AoR sJCWEDULE;MATCH EXISTING DOORS AND FRAMES, NEW DOORS WITH LEVER HANDLES 13C5 ETC. EXISTING DOORS NO CHANGES 1,2 NEW 3'-0" X T-0" SC WOOD (STAINED), METAL JAMB (PAINTED), I I/2 PAIR BUTTS, CLOSER, PUSH/PULL, KICKPLATES EACH SIDE, SILENCER, THRESHOLD (MAX 1/2" 3. NEW 3'-0" X T-0" SC WOOD )STAINED), METAL JAMB (PAINTED), 1 1/2 BUTTS, LATCHSET, SILENCER, WALL STOP ROOM SCI4E1DULE: 12 FLOOR: NEW SHEET VINYL WITH WELDED SEAMS BASE: NEW SHEET VINYL COVED 6" BASE FILE COPY WALL: WAINSCOT 4' PLASTIC LAMINATE GYP SD PAINT SGE GY BD PAINT, SGE l8' NOW o 1 1611 "CIO 3. FLOOR: SHEET VINYL WITH WELDED SEAMS BASE: SHEET VINY COVED . WALLS: WAINSCOT, 4!CV OROS GYP BD. PAIN SGE construction authorize CEILING: GYP BD P Y' E." of doornails � not authorize FULL W MI 0 MEN EL® tL ,: atton of any adopMd code or ordinsnce. Receipt is approved FiddCopysil . Isadmioai sdged: BY REVISIONS ges shall be made to t ATIOi 't work without prior appro Tu'swila Building Divisio -.)\.7s:ons will require • new p VED SWEET VINYL B ApA TOILET ELEVATION TYF' SCALE:IR" = SCALE:Ur = 1'-0 a MEN ELEVATION 0 0 0 © 0 0 14 U c1 9 . IP 11 II' I e e e a - o At 4oFo Mr - _ �_ i i _I . - _ a I f 1_ 1 Ih I` I > Iii � I SEE ADA RESTROOM ELEV. BELOW kEPARATE PER ErIiRochanical etlectrical ❑ Plumbing (,6as Piping fkwilaE . ao coER t1 I�it1!iA AT =40" 2. WATER UNDER SINKS 3. TOILET FLUSH VALVE ON THE WIDE SIDE OF ROOM 4. SHEET VINTL FLOORING WIN SEAM SEALER AND COVED 6" SHEET VINTL BASE. NORTH LOW UP SCALE: 1/8" = OS-30-13 NORTH SCALE: I/16" = 1'-0" 05-30-13 8 0 0 0 00 z 0x au_ RE IVE I ITY OF UK ILA CAN C:\Documente and SettingsAll Ueere\Dowments\CAD \1987-1989\8704-4\cd's reetmom 11-26-13530EING RESTR A 0 to (n = 0 �V) —< ZLi 3� CO (COH� mW •-U)0, 013 4:35:47 PM (3) Rae-. 6 3F-u l4V S190,h43 ys 6T� PPP r EVIEWED FOR C?DE COMPLIANCE 11 APPROVED MAR 2 6 2014 201/ RECEIVED CITY OF TUKWIL City of Tukwila MAR 1 0 2014 BUILDING DIVISION PERMIT CENTER HWSa c Y s 1 03S REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 6 2014 Oily of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 1 0 2014 PERMIT CENTER el) () 7 NEW BD S"X2Q.'GA JOISTS O.G. 5/S' G;YP CEILING ON STEEL AT 24" WITH SOUND ;gig r; / � / i@ �§ r INSULATION 1II .7. .�.'�tM,., � ti tHFlit$n NEW WOMEN RRID �,, . NEW 5/5' GYP BD CEILING ON 8'X2pCA STEEL JOISTS AT 24" O.G. WITH SOUND INSULATION , �l E " �aA t^krs ya. -•mp.. ' `'; � 'R= .. !:eu ^' • •• a: ': Wyj NEW JAN • DARK ROCK/fili U 17 I 011J UP AA: NEUJ NORTH SCALE: I/8" 1'-Q" LIGHTING CLACS.: BOTH RESTROOMS AND JAN = 342 SF X 0.S1W/SF = 311 WATTS INSTALLED 12 e 25 WATTS = 300, WATTS !IV NEW LIGHT SWITCH WITH DELAY FOR EXHAUST FAN NEW RECESSED COMPACT 1-1ALO4ENS,25 W A. NEW EXHAUST FAN TIED TO LIGHT SWITCH WITH DELAY, EXHAUST FAN TO OUTSIDE OF BUILDIN4- IOLL RAMP ATTACH BOTTOM TRACK TO CGRC. FLOOR V POWER OR AN ANCHOR& WILT( CR APPROVED I. EI1EgD1'ENT AT 34, DC. Y u r t lini REMOVE EX. WALLS AND DOORS, CAP ANY UNUSEDliffi 7 I MO t 3 f PLUMBING / o Q 4. 1 i�S II ii EIIIS\ I� e` 1,15 11# ttt � " x" S mgs*' ""T3i �i=Ny RR NEW MEN REMOVE EX. WALLS AND DOORS, CAP ANY UNUSED PLUMBING REMOVE GLG-. IN ARK ROOM AS , ROW _ - - f _ __ _ = MI ocw QARK%. 5/8• GYP. BD. ALGI TICAL ELAJ4'3T east, WAIL CONG :LAB ON WADE 111111Walt WAX. GYP. SD- TO FLOOR 4L &OM AV RN - WALLS LAW UP NORTH SCALE: I/8" = I'-m" NOTE. L %EMOVE EXISTING WALLS, DOORS, FLOORING, BASE AND FINISHES AS REQUIRED FOR NEW WORK- ?. PATCH FLOORS,LUALLS AND CEILING$ AT DEM'D AREAS 3. CAP ANY UNUSED PLUMBIN, PATCH WALLS AND FLOORS 4. PULL OUT ANY UNUSED LABELING AND PHONE 5. PULL OUT ANY UNSED ELECTRICAL, PUT IN J-BOX ABOVE CEILING IN AN ACCESSIBLE AREA, LABEL WITH PANEL NUMBER AND CIRCUIT NUMBER. REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 6 2014 ila BUILDING CDIVISION of T RECEIVED CITY OF TUKWILA MAR 1 0 22014 PERMIT CENTER 0 w a CHECKED BY DAVID 0 a c NO rn co on r1 KO KO I I r1 co N O N w 0x ¢ a EP:4 T=2 OI INTERIOR DOOR JAMB 5C4 I -VC • I'-0° 6EQICYI OPPEEERIMETER OF ICE TO WAREHOUSE WALL TO SLAB 0:4F-142.•I'-0' C:\Documerds and Satdngs MI Users\Documents\CAD\1987-198918704-01cd's reaWam 11-26-13180E1NG RESTR601715-91-28-13:dwg, 12, 11R1 t013 4:34:35 PM ffi Yu (I II � N NEW GYP BD CEILING ON 8"X20GA STEEL JOISTS AT 24" O.G. WITH SOUND r• !p I ITEM) T1 & . IKB a t20 INSULATION 131/ - o Q O "::114�^ ' gf:" Tj!�:i ::� C /j am e O � II'' u ''II u ..i, T2 crt NEW WOMEN RR NEW MEN V NEW 5/5' GYP BD CEILING ON .5"X20GA STEEL JOISTS AT 24" O.G. WITH SOUND INSULATION' ;3►. 4 » �%s•.. •'s;e;La,ss; :�•� a+,. r• • � �_"•""�•`'•��"%" s t tt �.: :%.� . :-';";;•- '- .. : . i^, -`-,:`y. C1yl NEW JAN • DARK ROM 17 f • Ii ) SLOW UP AREA: NEW CEIL1NC NORTH SCALE: I/S" = I'-0" LIGHTING CLACS� BOTH RESTROOMS AND JAN = 342 SF X 0.91W/SF = 311 WATTS INSTALLED 12 B 25 WATTS = 300 WATTS 0 NEW LIGHT SWITCH WITH DELAY FOR EXHAUST FAN • NEW RECESSED COMPACT HALOGENS, 25 W ® NEW EXHAUST FAN TIED TO LIGHT SWITCH WITH DELAY, EXHAUST FAN TO OUTSIbE OF BUILDING TYPIC4L WALL FRAM % ATTACH BOTTQ1 TRACK TO CCNC. FLOOR UY POLDER DRIVEN ANCHORS, HILTI OR APPROVED P EtEEDMEIT AT 24. OG 4-1- 1 116 FLoo fill to IJYu • Pplait in ftgli Fr REMOVE EX WALLS .f..\ AND DOORS, CAP t�ID �- 12Q \ ANY UNUSED a PL' =1TSG • I: LI• AA I III 0 1-t _ r r Q1 Ir,.• S\ e NEW WOMEN : . L. RR REMOVE EX. WALLS# s t t t AND DOORS, CAP ANY UNUSED PLUMBING _• - _ --- REMOVE CLG IN • ARK ROOM AS —G .T'... II GM . 1 /� RI 1457 5/S. GYP. Q. ACOUSTICAL BLANCET • WIND WALL CONC. SLAB ON GRADE CAULK GYP. BD. TO FLOOR • ALL SAND AND PRUL WALLS • BLOW UP AREA: DEMO WOTI4 SCALE: 1/8" = 1'-0" NOTE: 1. REMOVE EXISTING- WALLS, DOORS, FLOORING, BASE AND FINISHES AS REQUIRED FOR NEW WORK 2. PATCH FLOORS,WALLS AND CEILINGS AT DEM'D AREAS 3. CAP ANY UNUSED PLUMBING, PATCH WALLS AND FLOORS 4. PULL OUT ANY UNUSED CABELING AND PHONE 5. PULL OUT ANY UNSED ELECTRICAL, PUT IN J-BOX ABOVE CEILING IN AN ACCESSIBLE AREA, LABEL WITH PANEL NUMBER AND CIRCUIT NUMBER - REVIEWED FOR CODE COMPLIANCE APPROVED MAR 26 2014 City of Tukwila BUILDING DIVISION CORRECTION Ps& 11-1-003s RECEIVED CITY OF TUKWILA MAR 2 4 2014 PERMIT CENTER CHECKED BY DAVID 0 NO m(0 ID II K3 CD 00 N 03 Q x w i¢L �(/)rn ncm 0 ra • T-2 OINTERIOR DOOR JAMS SCALE I -VP • 1'.0' SECT1CNOPRIMETER OFFICE TO WAREHOUSE WAL SECTION O SC yZ• lecnaN C:1DocumenlR and SetHngs5il Users \ Documents \CAD\1987-19891670441cd's iestoom 1146-13\BOEING RESTROOMS 11-26.13.dw9, T-2, 11/25/2913 4:34:35 PM