Loading...
HomeMy WebLinkAboutPermit M15-0068 - RIVERTON APARTMENTS - BUILDING C - DUCTLESS HEAT PUMPRIVERTON APARTMENTS - BLDG C 14448 41$1 AVE S M15-0068 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 0040000240 14448 41ST AVE S MECHANICAL PERMIT Project Name: RIVERTON APARTMENTS - BLDG C Permit Number: M15-0068 Issue Date: 6/15/2015 Permit Expires On: 12/12/2015 Owner: Name: Address: KC HOUSING AUTHORITY 600 ANDOVER PARK W , TUKWILA, WA, 98188 Contact Person: Name: VIELKA ANSARI Phone: (253) 629-7952 Address: 2820 A ST, TACOMA, WA, 98402 RESICON LLC Phone: (253) 355-5565 19817 SUNNYSIDE DR N #J304 , SHORELINE, WA, 98133 License No: RESICL*8740F Expiration Date: 9/6/2015 Contractor: Name: Address: Lender: Name: Address: DESCRIPTION OF WORK: INSTALL DUCTLESS HEAT PUMP MINI SPLIT IN EACH UNIT (6) UNITS Valuation of Work: $7,000.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $285.10 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: Date: iow I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development perm;and agree titions attached to this permit. Signature: / ,� . / Print Name: LniM(4 6Z/S7-6I(fiA/ Date: / 7C- This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUK Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. lY .\ / 0" p V Project No. Date Application Accepted: Date Application Expires: Co-6-16r (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION ' j I' ( l(� (/ King Co Assessor's Tax No.: ZcOCTa4O Site Address: 1 `41U1U 4k1- 1 v Soutn ( C' Suite Number: N/A Floor: N/A Tenant Name: Riverton Terrace - King County Housing uthority New Tenant: ❑ Yes 0 ..No PROPERTY OWNER Name: King County Housing Authority Address: 600 Andover Park West City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Vielka Ansari Address: 2820 A Street City: Tacoma State: WA Zip: 98402 Phone: (253) 625-7952 Fax: Email: Vielka@Resiconllc.com MECHANICAL CONTRACTOR INFORMATION Company Name: Resicon LLC Address: 2820 A Street City: Tacoma State: WA Zip: 98402 Phone: (253) 625-7952 Fax: Contr Reg No.: RESICL*919N7 Exp Date: 08/19/2015 Tukwila Business License No.: BUS-0996147 Valuation of project (contractor's bid price): $ i 0 Describe the scope of work in detail: Install Ductless Heat Pump mini Split in each unit Use: Residential: Commercial: V�x.0 ld i� G i1C1-S (p U1uli-/- New ❑ Replacement ❑ New ❑ Replacement ❑ Fuel Type: Electric 0 Gas ❑ Other: H:\Applications\Forms-Applications 0n Line \201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWY Ii° A))ORIZE t A ENT: _ Signature: Print Name: Vielka Ansari Mailing Address: 2820 A Street Date: 06/03/2015 Day Telephone: (253) 625-7952 Tacoma WA 98402 City State Zip H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 201 I bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID $285.10 M15-0068 Address: 14448 41ST AVE S Apn: 0040000240 $285.10 MECHANICAL $274.13 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $186.80 PLAN CHECK FEE R000.322.102.00.00 0.00 $54.83 TECHNOLOGY FEE $10.97 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R5467 R000.322.900.04.00 0.00 $10.97 $285.10 Date Paid: Friday, June 05, 2015 Paid By: RESICON Pay Method: CHECK 1662 Printed: Friday, June 05, 2015 10:25 AM 1 of 1 rPWSYSTEMS roi INSPECTION RECORD Retain a copy with permit IN 'CT 0 0.PERMIT Nfl.� CITY OF TUKWILA BUILDINCN� �'f itikktf )0 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 et3v 0 MIS- 006 Project: �C�`�er i tr Type of Insp ctidwf: t A PB . (v•cd Address: I Li(gv 4(ST*ljeA Date Called: Special Instructions: _WI. 1 V Date Wanted: g .- i -/5- a.m. p.m. Requester: Phone No: Approved per applicable codes. L Corrections required prior to approval. CUM MENTS: or N/4 pip visu(�1- t"(f T 7- Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 i'1�Ilts �� Pr ect: Ki-04-0-7f—1 / rz,,� u^ Type of Inspection: I J /IeChi /4' Address: Date Called: Special Instructions: Si C, " t Date W �f-/2 /Santed:' a.m. P.m. Requester: Phone No: .Approved per applicable codes. Corrections required prior to approval. COMMENTS: inspector: .. ` Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. `.:=,!_'t i 1 k I y I, 1 ST 2 c T bUiLCA ( Si{ Okiiin ra, tJ L zf:R U.1,fh ;•A .J a. .1'1 p iiiJil.i l`NiC a • idR.�rt5 J 2 S1aF•��4 i. 0 0,73 13 73 o 011 ®02O O S n go O 13 G IS m O O ,B Om 2CL co < 2 CL � O = to po g m .. M m CA 5a: O a a CD m o =tom fr, E. 10 get RECEIVED CITY OF TUK ILA JUN052 5 PERMIT CEN R Z. 72 IN • ,I-717I I, LL I, L fl ." ••'• • f. L-- 0 • !!! O r ' I I / in k, .; 1 I • , 4 RECEIVED MTV OF TUKWILA JUN A 5 2015 PERMIT CENTER ELECTRICHI COOLING & HEATING Job Name: FILE M-SERIES SUBMITTAL DATA: MSZ-GEI2NA-8 & MUZ-GE12NA 12,000 BTU/H WALL -MOUNTED HEAT -PUMP SYSTEMS Location: Date: Purchaser: Engineer: Submitted to: For ❑Reference :Approval ❑Construction System Designation: Schedule No.: Indoor Unit MSZ-GE12NA-8 r"44 Most Efficient 2Q 13 Wireless Remote Ltd ���/// Controller ENERGY STAR www.rnnruystar.gnv GENERAL FEATURES • Wall -mounted indoor unit • Standard Hybrid Catechin Prefilter is included with indoor unit • Quiet operation • Auto fan speed control: Quiet, Low, Medium, High, and Super High; • Hand-held Wireless Remote Controller • Indoor unit powered from outdoor unit using A -Control • Auto restart following a power outage • Base heater is available as an option • Anti -allergy Enzyme Filter • Limited warranty: five years parts and seven years compressor ACCESSORIES Outdoor Unit o Base Heater (MAC-640BH-U) ❑ Drain Socket Assembly (MAC-860DS) Indoor Unit ❑ Condensate Pump (230V; SI3100-230) Controller Options ❑ Wireless Wall -mounted Remote Controller Kit (MHK1)* ❑ Portable Controller (MCCH1)* o Outdoor Air Sensor (MOS1)* *See Submittal for information on each option. o Wired Wall -mounted Controller (PAR-21MAAU requires MAC-3331F) o System Control Interface (MAC-333IF) Outdoor Unit: MUZ•GE12NA REVIEWED FOR CODE COMPLIANCE APPROVED JUN 10 2015 Ci �ofTukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 052015 PERMIT CENTER \Af* Specifications are subject to change without notice. (cl 9ni Miic ,hichi Flarfrir I IC Inr SPEMFICATIONS: MSZ-GE12NA-8 & MUZ-GE12NA Cooling* Rated Capacity 12,000 Btu/h Minimum Capacity 3,800 Btu/h SEER 20.5 Btu/hNV Total Input 960 W Heating at 47°F* ° Rated Capacity 14,400 Btu/h Minimum Capacity 5,500 Btu/h HSPF 10.0 Btu/hNV Total Input 1,170 W Heating at 17°F* Rated Capacity 8 800 Btu/h Rated Total Input 900 W Maximum Capacity** 11,200 Btu/h Maximum Total Input 1,200 W * Rating Conditions per AHRI Standard Cooling I Indoor: 80° F (27° C) DB / 67° F (19° C) WB Cooling I Outdoor: 95° F (35° C) DB / 75° F (24° C) WB Heating at 47°F I Indoor: 70° F (21° C) DB / 60° F (16° C) WB Heating at 47°F I Outdoor: 47° F (8° C) DB / 43° F (6° C) WB Heating at 17° F I Indoor: 70° F (21° C) DB / 60° F (16° C) WB Heating at 17° F l Outdoor: 17° F (-8° C) DB / 15° F (-9° C) WB ** Maximum Capacity is at full speed and performance for INVERTER -driven System. Electrical Requirements Power Supply 208 / 230V, 1-Phase, 60 Hz Breaker Size 15 A OPERATING RANGE Indoor Intake Air Temp. Outdoor Intake Air Temp. Cooling Maximum 90° F (32° C) DB 73° F (23° C) WB67° 115° F (46° C) DB Minimum 67° F (19° C) DB 57° F (14° C) WB 14° F (-10° C) DB Heating Maximum 80° F (27° C) DB 67° F (19° C) WB 75° F (24° C) DB 65° F (18° C) WB Minimum 70° F (21° C) DB 60° F (16° C) WB -4° F (-20° C) DB -5° F (-21° C) WB Voltage Indoor - Outdoor S1-S2 AC 208 / 230V Indoor - Outdoor S2-S3 DC ±24V Indoor - Remote Controller MHK1 DC 3V PAR-21 MAAU DC 12V PAR-FL32MA DC 3V Indoor Unit MCA 1A Blower Motor (ECM) 0.76 F.L.A. Airflow (Quiet - Lo - Med - Hi - Super Hi) Cooling 145 - 170 - 237 - 321 - 399 Dry CFM 109 - 134 - 201 - 286 - 364 Wet CFM Heating 145 - 170 - 237 - 321 - 406 Dry CFM Sound Pressure Level (Quiet - Lo - Med - Hi - Super Hi) Cooling 19 - 22 - 30 - 37 - 45 dB(A) Heating 19 - 22 - 30 - 37 - 43 dB(A) DIMENSIONS UNIT INCHES / MM W 31-7/16 / 799 D 9-1/8 / 232 H 11-5/8 / 295 Weight 22 lbs. / 10 kg External Finish Munsell No. 1.0Y 9.2 / 0.2 Field Drainpipe Size O.D. 5/8" / 15.88 mm Outdoor Unit Compressor DC Inverter -driven MCA 12A Fan Motor (ECM) 0.50 F.L.A. Sound Pressure Level Cooling 49 dB(A) Heating 51 dB(A) DIMENSIONS INCHES / MM W 31-1/2/800 D 11-1/4/286 H 21-5/8 / 549 Weight 77 lbs. / 35 kg External Finish Munsell No. 3Y 7.8 / 1.1 Refrigerant Type R410A Refrigerant Pipe Size O.D. Gas Side 3/8" / 9.52 mm Liquid Side 1/4" / 6.35 mm Max. Refrigerant Pipe Length 65 ft. / 20 m Max. Refrigerant Pipe Height Difference 40 ft. / 12 m Connection Method Flared Notes: Specifications are subject to change without notice. © 2013 Mitsubishi Electric US, Inc. DIMENSIONS: MSZ-GE12NA-8 & MUZ-GE12NA MSZ-GEI 2NA-8 9-1/8 3/16 N 1-3/4 1- 7116■1 Oblong hole Installation plate 31-7/16 30-15/16 1/4 Indoor unit 3-1/8 8-7/8 8-7/8 CO t u 'n 15/16_I I 24-3/8 15-1l81 fl I 12-3/16 co fl 1.15/16_1 1 mt 2-3/ to rTS 0 • Unit: inch 7/16x13/16 Oblong hole 3-1/8 co n ro 0S 0, m 6-1/8 6-1/8 13-5/16 Air in 13-9/16 Installation ate CO . 1- "2 �- 2-1/8 Wall hole e2-9/16 Pi in Air out 1-5/8 /3/1 4-3/8 \Drain hose cn n a Insulation 01 - 3/8 0.D - Liquid line e1/4 19 -11/16 (Flared connection 01/4) Gas line 03/8 16 - 15/16 (Flared connection: 03/8 (GE06109/12NA), e112 (GE15118NA)) Drain hose Insulation e1-1/8 0.D Connected part 05/8 0.D MUZ-GE1 2NA 15-3/4 Air in Drain hole 01-5/8 Air in b ‘5 Air out 7/8 co rn r, A 1-9/16 2- 3/8 x13/16 Oval hole ins handle IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII II1IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII1I IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1111111111111111111111111111111111111111 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII IIIIIIIIIIIIIIIIIIIII'IIIIIIII1111111111 IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1-29/32 ,5-1511f_ 19-11/16 31-1/2 2-23/32 REQUIRED SPACE 29/32 11-1/4 17/32 Unit: inch Basically open 4 inch or more without any obstruction in front and on both sides of the unit. Open two sides of left, right, or rear side. Liquid pipe :1/4 (flared) Gas pipe :3/8 (flared) (GE09/12) 1/2 (flared) (GE15) stimuli" iui CERTIFIED ED� . •tadu.ahrimtectu y.org ,llmtar/ Small HP .4I11RRI Standard 21100/240 E'WiGc�A�,3G .,tlYA,it3.{�`.s�c,""!• �h��', Intertek MITSUBISHI ELECTRIC COOLING & HEATING Live Better 1340 Satellite Boulevard Suwanee, GA 30024 Tele: 678-376-2900 • Fax: 800-889-9904 Tot Free: 800-433-4822 www.mehvac.com FORM# MSZ-GE12NA-8 MUZ-GE12NA- 201304 Specifications are subject to change without notice. © 2013 Mitsubishi Electric US. Inc. How does the sound decrease with distance? sound pressure distance wave drop decrease ... Page 8 of 13 1.0 0.9 N 0.8 0.6 g 0.5 O 0.4 4) f tc3 O. 71) 0.2 0.1 0 4 5 6 7 8 9 10 1/32 = 1/9 = 0.1111 1/42 = 1/16 = 0.0625 1/52 = 1/25 = 0.0400 1/62 = 1/36 = 0.0278 1/72= 1/49 = 0.0204 1/82 = 1 /64 = 0.0156 1/92 = 1/81 = 0.0123 1/102=1/100 = 0.0100 REVIEWED F CODE COMPLIi APPROVE 1 2 3 4 5 6 7 8 9 10 Relative distance ri l r2 Sound Level L and the Distance Distance -related decrease of sound level OR ONCE 1) 5 RECEIVED CITY OF TUKWILA JUN 1152015 PERMIT CENTER JUN 10 20' 19/ Ci of Tukwila C'J LCINC !DIVISION htto://www.seneoielaudio.com/calculator-SoundAndDistance.htm 6/4/2015 How does the sound decrease with distance? sound pressure distance wave drop decrease ... Page 9 of 13 Sound is here the sound level, whether it is the sound pressure level or the sound intensity level. 3 Zv fob Reference distance ri from sound source Sound level L1 at reference distance r1 too m or ft 51 dBSPL Another distance r2 from sound source Sound level L2 at another distance r2 3.2 m or ft 40.9 ;dBSPL reset calculate 1 Mix c/BSPL Measu4-eot IA +esgj ttt 1 M •6 Mvl owleICOf UAi a `i- Wew 4801- level 6t4 3fZ_M or alproXlvvicat l0 ffi Calculation of the distance r2 where we get the specific sound level L2. Sound level Li at reference distance r1 Reference distance from sound source r1 1100 dBSPL too m Sound level L2 at another distance r2 Another distance from sound source r2 94 dBSPL m reset calculate 1 Formulas to calculate the sound level L in dB (sound pressure level or sound intensity level) in dependence of the distance r from a sound source. Sound levelL and Distance r L2 = Ll 1 20 • log Q., 20 r = 2 I2 2 _Ll-11O•iog 12 J1 r1L1-L2I 10- z" f2 2 Often we talk only of sound level. However, sound pressure as a sound field size is not the same as sound intensity as a sound energy size. Levels of sound pressure and levels of sound intensity decrease equally with the distance from the sound source. Sound power or sound power level has nothing (!) to do with the distance from the sound source. Thinking helps: A 100 watt light bulb has in 1 m and in 10 m distance really always the same 100 watts, which is emitted from the Tamp all the time. Watts don't change with distance. http://www.sengpielaudio.com/calculator-SoundAndDistance.htm 6/4/2015 3-12. SOUND PRESSURE LEVELS MSZ-GE24NA OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB . 0.0002 pbar) 90 80 70 6 5 4 3 2 NOTCH SPL(dB(A)) LINE COOLING(Raled) 53 •---• HEATING(Rated) 53 o --0 1 KOMI= algalinela NC-70I Erarmi NC-60i sue_ �j �� M kV M. � NC-501 ainalallima`....wool' NC-"I Ncso APPROXIMATEeMi THRESHOLD OF HEARING FOR CONTINUOUS NOISE a NC-20I 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz (2) Outdoor Unit MUZ-GEO9NA2 OCTAVE BAND SOUND PRESSURE LEVEL, dB (0 dB. 0.0002 pbar) 90 80 70 6 5 4 2 NOTCH SPL(dB(A)) LINE COOLING 46 140 HEATING 50 O- O IN 0 11M1111.111 II LAVSNIIII II IIIIRISOMPri "MI% 11,1141.41rblia SE �� � 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz WALL UNIT 39-3/8 inch (1m) 31-1/2 inch (0.8m) MICROPHONE • NOTE:The sound level is measured in an anechoic room where echoes are few,when compressor stops.The sound may be bigger than displayed level under actual installation condition by surrounding echoes.The sound level can be higher by about 2 dB than the displayed level during cooling and heating operation. MUZ-GE12NA2 90 c 80 70 o e 60 w 5 D N K a 4 ° ° 3 U 2 1 1 apse love-1s W measured cz 1- NOTCH (SPL(dB(A)) LINE COOLING 49 • HEATING ` 51 •--0 0 0L 0 kb71111— — NC 70I `-�mimim NCbOI WW a k ill _NC-�i 1INCI �i WAWA - APPROXILI THRESHOLD OF HEARING FOR CONTINUOUS NOISE 1 Nom = NC-201 63 125 250 500 1000 2000 4000 8000 BAND CENTER FREQUENCIES, Hz ere / trc'wl i,u (r Due to continuing improvement, above specification may be subject to change without notice. tAC7-0.FNIA9_1R 11Ac7In0I 17..ncto ) LJ -,+ D,,..... C..c4r,...c /A,,,.,7M A\ IIITCI IDICUI el Cr.TDIf' rnoD/1DATIrtM PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0068 DATE: 6/5/15 PROJECT NAME: RIVERTON APARTMENTS - BLDG C SITE ADDRESS: 14448 41ST AVE S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: (-0I-1 Buil j ing Division la Public Works Fire Prevention Structural AwJ)Ci ME Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 6/9/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 7/6/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 RESICON LLC Page 1 of 2 Home 'Inicio en Espafiol Contact Search L&I A %Index Help My Secuit L&I Safety Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & !Industries RESICON LLC Owner or tradesperson Principals CHRISTENSEN, CRAIG ALLEN, PARTNER/MEMBER Doing business as RESICON LLC WA UBI No. 602 942 448 2820 A STREET TACOMA, WA98402 253-355-5565 KING County Business type Limited Liability Company Governing persons CRAIG CHRISTENSEN VIELKA ANSARI; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. RESICL*919N7 Effective — expiration 08/27/2009— 08/19/2015 Bond ................. American Contractors Indem CO Bond account no. 100229176 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/16/2013 08/19/2013 Expiration date Until Canceled Bond history Insurance ............................ Starr Surplus Lines Insurance Policy no. SLPG-GL02783-00 $1,000,000.00 Received by L&I Effective date 08/19/2014 08/19/2014 Expiration date 08/19/2015 Arch Insurance Co Policy no. ag100336800 $1,000,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602942448&LIC=RESICL*919N7&SAW= 06/15/2015