Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0081 - SOUND TRANSIT - AIR CONDITIONING UNIT
SOUND TRANSIT 11005 E MARGINAL WAY S M15-0081 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0323049029 Permit Number: M15-0081 11005 E MARGINAL WAY S Project Name: SOUND TRANSIT Issue Date: 12/28/2015 Permit Expires On: 6/25/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: D&C INVESTMENTS LLC 720 RAINIER AVE S , RENTON, WA, 98057 NICOLE SIEBEL 401 S JACKSON ST , SEATTLE, WA, 98104 AFFIDAVIT ON FILE 11/ Phone: (206) 370-5693 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALLATION OF AIR CONDITIONING UNIT AT EXISTING TRACTION POWERED CENTRAL LINK LIGHT RAIL SUBSTATION Valuation of Work: $11,170.00 Type of Work: Fuel type: Fees Collected: $350.42 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Permit Center Authorized Signature: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. AA Date Application Accepted: tQ91 16- 11D Application Expires: 12 1 14 (For office use only) 1Aiy- ae� MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 1 r�1 1 7 East Marginal Way South, Tukwila Suite Number: Floor: CPSRTA (Sound Transit) New Tenant: ❑ Yes m ..No PROPERTY OWNER Name: CPSRTA Address: 401 S Jackson Street City: Seattle State: WA Zip: 98104 CONTACT PERSON — person receiving all project communication Name: Nicole Siebel Address: 401 S Jackson Street City: Seattle State: WA Zip: 98104 Phone: (206) 370-5693 Fax: Email: nicole.siebel@soundtransit.org King Co Assessor's Tax No.: MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Installation of air condition unit at existing traction powered Central Link Light Rail substation. 11,170 Use: Fuel Type: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Electric Gas ❑ Other: H:1Applications \Forms -Applications On Line12011 Applications\Mechanical Permit Application Revised 8.9- I1.docs Revised: August 2011 bh Page I of 2 4 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace > l 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ONIVNRc AU Signature: I �� D AGENT: Dater 0 s i Print Name: Nicole Siebel for CPSRTA Day Telephone: (206) 370-5693 Mailing Address: 401 S Jackson Street H:\ApplicationsWorms-Applications On Line\2011 Applications \Mechanical Permit Application Revised 8.9.11.docx Revised: August 2011 bh Seattle WA 98104 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT QUANTITY PAID PermitTRAK $1,308.80 EL15-0589 Address: 11060 TUKWILA INTERNATIONAL BLVD BLDG Apn: 0323049029 $303.98 ELECTRICAL $289.50 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $289.50 TECHNOLOGY FEE $14.48 TECHNOLOGY FEE I R000.322.900.04.00 0.00 $14.48 EL15-0590 Address: 4524 S 134TH PL Apn: 2613200007 $303.98 ELECTRICAL $289.50 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $289.50 TECHNOLOGY FEE $14.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $14.48 M15-0080 Address: 4524 S 134TH PL Apn: 2613200007 $350.42 MECHANICAL $336.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $67.39 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE R000.322.900.04.00 0.00 $13.48 M15-0081 Address: 11060 TUKWILA INTERNATIONAL BLVD BLDG Apn: 0323049029 $350.42 MECHANICAL $336.94 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $237.05 PLAN CHECK FEE R000.322.102.00.00 0.00 $67.39 TECHNOLOGY FEE $13.48 TECHNOLOGY FEE R000.322.900.04.00 TOTAL FEES PAID BY RECEIPT: R5633 0.00 $13.48 $1,308.80 Date Paid: Monday, June 29, 2015 Paid By: CPSRTA (SOUND TRANSIT) Pay Method: CREDIT CARD 087034 Printed: Monday, June 29, 2015 11:17 AM 1 of 1 CSYSTEMS INSPECTION RECORD 1 00e/ Retain a copy with permit INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: tl.Uta -7'I2AeJS i- — Type of Inspection: )1,1G-c 14i9F 1(AL /' 7 4 L Address: 1 /oOS E— n9, i i /AL 09 Date Called: Special Instructions: Date W� e �� � / a r . p.m. Requeste Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: A4141 Datea/A� �O REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. GL� Non -Critical Instrument House HVAC Installation Cutsheets RECEIVED CITY OF TUKWILA JUN 2 9 2015 PERMIT CENTER Page 3 of 11 Motor BHP I 1.48 II 1.06 II 1.22 1I 0.79 Octave Center freq. 63 125 (a)Blower Operation 78 76 (b)Cooling Operation 84 78 (a)Blower Operation 77 75 (b)Cooling Operation 84 77 (a)Blower Operation 75 73 (b)Cooling Operation 83 76 (a)Blower Operation 77 73 (b)Cooling Operation 84 76 250 68 69 68 1 69 65 67 67 68 500 63 63 64 64 60 61 62 63 1000 58 58 60 60 54 55 59 59 2000 4000 8000 54 54 54 54 50 51 53 53 53 47 53 47 51 44 51 45 49 42 49 44 49 42 50 44 (a) Blower Operation = supply fan only sound power, dB re 0-12 W. (b) Cooling Operation = supply fan, compressor, and condenser fan, dB re 10 '12W. (c) Test duct dimension: 14 inches wide by 24 inches high by 6 feet long (0.36 m X 0.61 m X 1.83 m) for side ducted inlet; Tes duct termination is flush with the wall in the reverberation room; No test duct elbow (Duct end (sound reflection) correction: (9,5,2,1,0,0,0,0) dB for side ducted inlet at (63,125,250,500,1k,2k,4k,8k) Hz Base unit 4 & 5 ton Precedent direct or belt drive with Horizontal Configuration Sound component Ducted Discharge Power source 60Hz. Motor tap (high/low) High Low Supply fan speed (rpm) 1061 1124 920 1076 Supply fan S.P. (in H20) 0.55 1.18 0.42 1.17 Supply fan CFM 1728 1024 1475 890 Motor BHP 1.5 1.06 1.22 0.79 Octave Center freq. (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation 63 87 92 87 92 83 92 85 92 125 81 82 79 72 81 77 79 78 79 250 75 76 73 72 73 71 72 500 73 73 69 70 69 69 68 68 1000 69 69 66 66 65 66 65 65 2000 65 66 62 63 61 62 61 62 4000 63 63 59 60 59 60 57 59 8000 56 57 52 53 51 53 50 52 a) Blower Operation = supply fan only sound power, dB re 10-12 W. b) Cooling Operation = supply fan, compressor, and condenser fan, dB re 10-12 W. (c) Test duct dimension: 15.5 inches wide by 18 inches high by 6 feet long (0.39 m X 0.46 m X 1.83 m) for side ducted discharge Test duct termination is flush with the wall in the reverberation room; No test duct elbow (d) Duct end (sound reflection) correction: (10,6,2,1,0,0,0,0) dB for side ducted discharge at (63,125,250,500,1 k,2k, 4k,8k) Hz Base unit Sound component Power source 4 & 5 ton Precedent direct or belt drive with Downflow Configuration Ducted Discharge 60Az. II II http://tranenetclkl/common/clkpsodocs/PrecedentSoundData.htm 3/14/2006 System Lineup PRODUCT MODELS AND CONTROLLERS 'u- I ACV - 2 Indoor Unit IVodels Mitsubishi Electric indoor units are available in a wide variety of styles and capacity ranges to provide an almost unlimited number of applications. If there is a problem, we have a solution. PKA (HA/HAL, KA/KAL) WALL -MOUNTED SERIES Air -Conditioner and Heat Pumps 12,000 to 34,200 Btu/h • PKA-HAUKAL use a wireless hand-held controller • Ideal utilization in the following spaces: Churches, classrooms, day care centers, out buildings, guard houses, and more PCA CEILING -SUSPENDED SERIES Air -Conditioner and Heat Pumps 24,000 to 42,000 Btu/h • i-see Sensor optional • Knockout for ventilation air • AUTO fan speed control • Ideal for applications such as: Restaurants, classrooms, building entrances, retails stores, quick additions and renovations PLA CEILING -RECESSED SERIES Air -Conditioner and Heat Pumps 12,000 to 42,000 Btu/h • Built-in condensate lift mechanism • i-see- sensor optional • Knockouts for ventilation air and branch duct run • Ideal utilization in the following spaces: Retail stores, classrooms, office spaces, conference rooms, lobbies, and more PEA/PEAD HORIZONTAL DUCTED SERIEF Air -Conditioner and Heat Pumps 12,000 to 42,000 Btu/h • Automatic fan speed control • Built-in condensate lift mechanism • Ideal utilization in the following spaces: Retail stores, classrooms, office spaces, conference rooms, lobbies, and more 30 AMITSUBISHI ELECTRIC r Rat 1, ,, r • , The Mitsubishi Electric built INVERTER -driven compressors for models PUY/Z- A18/24/30/36 are DC twin -rotor type, and the compressor for model PUY/Z- A42 is a Frame Compliant Scroll compressor. All compressors are part of the Variable Speed Inverter Drive Technology, which varies the compressor speed dynamically to match the room load, increasing the efficiency of the system and r . resulting in significant energy savings. Electronic linear expansion valves are • used to measure precisely and provide fine controls to the refrigerant flow _ „ ; ensuring exact capacity delivery. The outdoor units employ advanced Pulse Amplitude Modulation (PAM) circuitry. PAM adjusts the form of the current output wave to emulate the form of the supply voltage wave to effectively utilize 98% of the input power supplied. • : Outdoor Unit Models The Mitsubishi Electric P-Series outdoor units, either cooling -only (PUY) or heat i:; ; pump (PUZ) models, are compatible with each of the four different style indoor . units, creating a wide range of installation possibilities. The outdoor units are completely assembled, piped, wired, and test run at the • factory. The rugged, heavy-duty cabinet is constructed from a galvanized steel plate, finished with an electrostatically applied, thermally -fused acrylic or - polyester powder coating for corrosion protection. The front fan grille is ', high -impact ABS plastic. ,4cc-I PUY/PUZ-NHA3 Cooling -only and Heat Pump 12,000 to 18,000 Btu/h Acc-2 24,000 to 36,000 Btu/h rL 42,000 Btu/h PUZ-HA**NHA2 (H2i Hyper -Heating INVERTER 30,000 to 36,000 Btu/h (See page 44 for more information) Set Temperature Timer Menu Mode Set Time WIRED REMOTE CONTROLLER • 1, . , C. *,..ti�.e...a.,,.,... CE «.w0 Wired controller for the indoor unit. (multi-lingual) On/Off Fan Speed Filter Test Run Check Airflow Up/Down Louver Ventilation J.MITSUBISHI ELECTRIC 31 IPIiA-AOCKA MUDEL SVOWN) IFYR ' PKA COOLING -ONLY i - :- -4a -I HA/KA = Wired controller HAUKAL = Wireless controller BS = Seacoast Protection W IM7RL114 i71:�. a:kitk, au:b:ai21i 17; effsfj(5° 17:4,w ;r d:1(5, 17.,ti•WIAL9. u[TJ4 t(E r ,a , r r 7e . IIYM_`CI?k'( lri !Wm. • ::atiirl�r21Trallil3` �'d k�'ilfjVEt: Rated Capacity Muni1 il'Jef:ia n00 18,000 24,000 30,000 34,200 I Capacity Range 8tu/h 6,000-12.000 8,000-18,000 12.000.24,000 12,000-30,000 12,000.34,200 '1 Total Input W 1,190 2,240 2,270 4,130 5,030 Cooling Energy Efficiency SEER 15.2 15.3 17.0 . 15.5 14.0 Moisture Removal Pints/h 2.0 5.2 5.0 8.1 9.2 Sensible Heat Factor 0.81 0.68 0.77 0.70 0.70 Power Supply Phase, Cycle, Voltage 1-phase, 60Hz, 208 / 230V'2 Indoor - outdoor Si - S2 AC 208 / 230V Indoor - Outdoor S2 - S3 DC24 Voltage Indoor - Remote Controller 0C12V: Wired Type (HA/KA) Indoor - Remote Controller Wireless Type (HAUKAL) MCA A 1 Fan Motor F.L.A. 0.33 0.36 0.57 Fan Motor Output W 30 56 56 DRY (CFM) 320-370-425 635-705-775 705-810-920 Airflow (Lo-Mid•Hi) WET (CFM) 290-335-380 570-635-700 635-730-830 Sound Pressure Level (Lo•Mid-H) dB(A) 36-40-43 39-42-45 43-46-49 Indoor Unit External Finish Color Munseii No. 1.0Y 9.2 / 0.2 W: In. 35-3/8 46-1/16 1 Dimension Unit D:In. 9-13/16 11-5/8 H: In. 11-5/8 14-3/8 Weight Unit Lbs. 29 46 Feld Drainpipe Size I.D. In. 5/8 MCA A 13 18 25 MOCP A 15 I 20 30 40 Fan Motor F.L.A. 0.35 0.75 Fan Motor Output W 40 75 Model (Type) DC INVERTER -driven Twin Rotary Compressor R.L.A. 12 L.RA. 14 I 17.5 Unit Airflow CFM 1,200 I 1,940 Outdoor Refrigerant Control Linear Expansion Valve Sound Pressure Level at Cooling '1 dB(A) 46 48 External Finish Color Munsell No. 3Y 7.8 / 1.1 W: In. 31-1/2 37.3/8 Dimensions D: In. 13 + 7/8 13 + 1-3/16 H: In. 23-5/8 37-1/8 Weight Lbs. 90 I 97 163 Remote Controller Type HA/KA: Wired Controller; HAUKAL: Wireless Controller (Packaged with Indoor Unit) Type R410A Charge Lbs. 2,14 I 3,12 6,10 Refrigerant Oil Type (fl. oz.) MEL56 (20) FVSOS (28) Gas Side Q.D. In. 1/2 5/8 • Refrigerant Pipe Liquid Side O.D. In. 1/4 3/8 Height Difference (Max.) Ft. 100 Refrigerant Pipe lengih Length (Max.) Ft. 100 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. '1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C). Indoor units receive power from outdoor units through field -supplied interconnected wiring. .ipecificatioris are subject to change wtthout notice. LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts. 34 .e.MITSUBISHIELECTRIC Job Information 3-10 Ton R-410A PKGD Unitary Cooling Rooftop r E 4Ac-i 1 Sound Transit Track Power Substation Seattle Main Office (Y31)Michael Woods Tag Quantity Unit Information AC-5T 1 Model number THC060 Tonnage 5 Ton Min. Unit Operating Weight 679.0 lb Design Airflow 2000 cfm Unit function DX cooling Max Unit Operating Weight 900.0 Ib Cooling Information Gross Total Capacity 65.86 MBh Gross Sensible Capacity 65.86 MBh Gross Latent Capacity 0.00 MBh Net Total Capacity 63.39 MBh Net Sensible Capacity 63.39 MBh Net Sensible Heat Ratio 1.00 Number Cooling Entering Dry Bulb 90.00 F Cooling Entering Wet Bulb 53.00 F Cooling Leaving Unit DB 61.08 F Cooling Leaving Unit WB 39.33 F Ambient Temp 85.00 F Heating Information Heating capacity Without electric heat Motor/Electrical Information Voltage 208-230/60/1 Design ESP 0.700 in H2O Indoor Motor Power 0.60 kW Indoor Mtr. Operating Power 0.81 bhp Compressor Power 3.20 kW System Power 4.17 kW MCA 41.40 A MOP 60.00 A Condenser Fan FLA 2.50 A Evaprator Fan FLA 7.60 A Compressor 1 RLA 25.00 A Electrical values provided are estimated only and are subject to change without notice and may differ from nameplate values. Field installed low or high static drive kits may be needed. Please check the fan performance tables in the product catalog for application ranges. 01172013 Product Version 1.0.0.0 Page 1 of 2 3-10 Ton R-410A PKGD Unitary Cooling Rooftop Job Information • TRANE' Sound Transit Track Power Substation Seattle Main Office (Y31)Michael Woods Tag AC-5T Quantity 1 Model number THC060 Information for LEED Projects ASHRAE 90.1 Yes IEER Rating 0.00 Refrig charge (HFC-410A) - ckt 1 6.1 lb Compressor Power 3.20 kW Refrig charge (HFC-410A) - ckt 2 0.0 Ib Outdoor Motor Power 0.37 kW Rated capacity (AHRI) 61.00 MBh Indoor Mtr. Operating Power 0.81 bhp EER @ AHRI Conditions 14.8 EER Exhaust fan power 0.65 kW Note: This product meets the minimum equipment efficiency requirements of ASHRAE Standard 90.1-2007 and -2010 (which are based on AHRI standard rating conditions) and, therefore, also meets the LEED *Minimum Energy Performance' prerequisite in the Energy and Atmosphere section. The power data listed above is at actual user -entered conditions. Refer to the product catalog for performance at AHRI standard rating conditions. The LEEO Green Building Rating System., developed by the U.S. Green BoMing Council, provides independent, third -party vertfrration that a ba ldug pealed meets green building end performance measures. Electrical values provided are estimated only and are subject to change without notice and may differ from nameplate values. Field installed low or high static drive kits may be needed. Please check the fan performance tables in the product catalog for application ranges. 6117/2013 Product Version 1.0.0.0 Page 2 of 2 • TRANE Sound Transit Track Power Substation EVAPORATOR SECTION ACCESS PANEL CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA. HOLE 4 1/4" 27 5/8" 47 718" 2" ELECTRICAL CONNECTION (SINGLE POINT POWER WHEN HEAT INSTALLED) THROUGH THE BASE CONDENSATE PLAN VIEW UNIT DIMENSION DRAWING RETURN 1 SUPPLY 237/8" —19 1/4" —88 5/8" CONDENSATE 7- 00 9 3/8" —18 3/4"—"'" 32 1/4" PACKAGED COOLING DIMENSION DRAWING 4 3/4" 3 7/8" TOP PANEL 3-10 Ton R410A PKGD Unitary Coding Rooftop (NC) Items: AC-5T (This item is not 'In Job') 6/17/2013 10:48:04 AM CONDENSER FAN CONDENSER COIL NIT CONTROL WIRE 7/8" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA. HOLE UNIT POWER WIRE ONTROL AND COMPRESSOR ACCESS PANEL NOTES: 1. THRU -THE -BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. HORIZONTAL AIR FLOW TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 1 MANE' Sound Transit Track Power Substation 3-10 Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not' In Job') 6/17/2013 10:48:04 AM 3/4"-14 DIA HOLE CONDENSATE DRAIN 27 5/8" ISOMETRIC -PACKAGED COOLING 4 3/4" TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 2 Sound Transit Track Power Substation 3-10 Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not' In Job') 6/17/2013 10:48:05 AM 'ELECTRICAL / GENERAL DATA GENERAL (2)(4)�) Model: THCO6OF Unit Operating Voltage: '187-253F Unit Primary Voitage: 208 Unit Secondary Voltage 230 Unit Hertz: 60 Unit Phase: 1 SEER '15.0 Standard Motor Oversized Motor Minimum Circuit Ampacity: '41.4 Minimum Circuit Ampacity. N/A Maximum Fuse Size: 60.0 Maximum Fuse Size: N/A Maximum (HACR) Circuit Breaker. 60.0 Maximum (HACR) Circuit Breaker. N/A ' Field Installed Oversized Motor Minimum Circuit Ampacity. 'N/A Maximum Fuse Size: N/A Maximum (HACR) Circuit Breaker. NIA INDOOR MOTOR Standard Motor Outsized Motor Field Installed Oversized Motor Number. '1 Number: N/A Number: 'N/A Horsepower. 1.0 Horsepower. N/A Horsepower. N/A Motor Speed (RPM): — Motor Speed (RPM): N/A Motor Speed (RPM): N/A Phase: 1 Phase: N/A Phase: N/A Full Load Amps: 7.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: — Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: '1 Number. '1 Horsepower: 4.4 Horsepower. 0.40 Phase: 1 Motor Speed (RPM): 1075 Rated Load Amps: 25.0 Phase: 1 Locked Rotor Amps: 134.0 Full Load Amps: 2.5 Locked Rotor Amps: 6.6 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT {2) (Field Installed Power Exhaust) Type 'R-410 Phase: N/A Type: Throwaway Horsepower. N/A Furnished: Yes Factory Charge Motor Speed (RPM): N/A Number 4 Circuit 81 .6.1 lb Full Load Amps: N/A Recommended 16"x25"x2' Circuit 42 N/A Locked Rotor Amps: N/A NOTES: 1. Maximum (HACR) Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions. 3. Value does not Include Power Exhaust Accessory. 4. Value includes oversized motor. 5. Value does not include Power Exhaust Accessory. 6. EER Is rated at AHRI conditions and in accordance with DOE test procedures. TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 3 Sound Transit Track Power Substation TRANE 3-10 Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not 'In Job') 6/17/2013 10:48:05 AM CORNER WEIGHT INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 36.0 Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST HEATER REHEAT THROUGHT THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD 20,0 Ib SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET UA 219.01b © 135.0Ib (E) LENGHT (F) WIDTH 774.0 Ib 679.0Ib BU 189.0 Ib O O 137.0 Ib 43" 21" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE <5 LBS. RIGGING AND CENTER OF GRAVITY TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 4 8 TRANE° Sound Transit Track Power Substation 3-10 Ton R410A PNGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not 'in Job') 6/17/2013 10:48:05 AM CLEARANCE 36" CLEARANCE 48" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED COOLING CLEARANCE ROOF OPENING — UNIT OUTLINE 46" 46" J CLEARANCE FROM TOP OF UNIT 72" 53 1/4" 88 5/8" PACKAGED COOLING DOWNFLOW TYPICAL ROOF OPENING TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 5 Sound Transit Track Power Substation rRarE° 3-10 Ton R410A PKGD Unitary Coding Rooftop (T4C) Items: AC-5T (This item is not 'In Job') 6/17/2013 10:48:05 AM . .. o T 00 ECONOMIZER HOOD 00 ACCESSORY ECONOMIZER HOOD ^_--- 16 3/4" ECONOMIZER HOOD 6 7/8" 9 TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 6 Page 3 of 11 Motor BHP 1.48 1.06 1.22 0.79 Octave Center freq. (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation 63 78 84 77 84 75 83 77 84 125 76 78 75 77 73 76 73 76 250 68 69 68 69 65 67 67 68 500 63 63 64 64 60 61 62 63 1000 58 58 60 60 54 55 59 59 2000 54 54 54 54 50 51 53 53 4000 53 53 51 51 49 49 49 50 8000 47 47 44 45 42 44 42 44 (a) Blower Operation = supply fan only sound power, dB re 1012 W. (b) Cooling Operation = supply fan, compressor, and condenser fan, dB re 10 -12W. (c) Test duct dimension: 14 inches wide by 24 inches high by 6 feet long (0.36 m X 0.61 m X 1.83 m) for side ducted inlet; Test duct termination is flush with the wall in the reverberation room; No test duct elbow (d) Duct end (sound reflection) correction: (9,5,2,1,0,0,0,0) dB for side ducted inlet at (63,125,250,500,1k,2k,4k,8k) Hz Base unit 4 & 5 ton Precedent direct or belt drive with Horizontal Configuration Sound component Ducted Discharge Power source 6011z. Motor tap (high/low) H'gh Low Supply fan speed (rpm) 1061 1124 920 1076 Supply fan S.P. (in H20) 0.55 1.18 0.42 1.17 Supply fan CFM 1728 1024 1475 890 Motor BHP 1.5 1.06 1.22 0.79 Octave Center freq. (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation (a)Blower Operation (b)Cooling Operation 63 87 92 87 92 83 92 85 92 125 81 82 79 81 77 79 78 79 250 75 76 72 73 72 73 71 72 500 73 73 69 70 69 69 68 68 1000 69 69 66 66 65 66 65 65 2000 65 66 62 63 61 62 61 62 4000 63 63 59 60 59 60 57 59 8000 56 57 52 53 51 53 50 52 (a) Blower Operation = supply fan only sound power, dB re 10'12 W. (b) Cooling Operation = supply fan, compressor, and condenser fan, dB re 10'12 W. (c) Test duct dimension: 15.5 inches wide by 18 inches high by 6 feet long (0.39 m X 0.46 m X 1.83 m) for side ducted discharge Test duct termination is flush with the wall in the reverberation room; No test duct elbow (d) Duct end (sound reflection) correction: (10,6,2,1,0,0,0,0) dB for side ducted discharge at (63,125,250,500,1k,2k, 4k,8k) Hz Base unit Sound component Power source 4 & 5 ton Precedent direct or belt drive with Downflow Configuration Ducted Discharge II 60Hz. II http://tranenetclkl/conunon/clkpsodocs/PrecedentSoundData.htm 3/14/2006 1.5-5 ton Pkgd. Cooling Rooftop Convert. R-410A Job Information TROVE' Sound Transit Track Power Substation Seattle Main Office (Y31)Michael Woods Tag Model number Quantity AC-4T 1ph 4TCY4048-1000 1 Refrigerant Cooling Capacity Electrical characteristics Unit Information AHRI Capacity Design Airflow Design net total capacity Design net latent capacity Cooling EDB Cooling EWB Design heating capacity Cooling Information R-410A Pkg cooling 14 SEER 4 Ton 14 SEER 208-230/1/60 48500.00 Btu/hr 1400 cfm 48706.00 Btu/hr 12529.00 Btu/hr 80.00 F 67.00 F SEER @ AHRI Field applied voltage Design net sensible capacity Cooling LDB Cooling LWB Electric heat capacity @ 206 volts Heating LDB Low speed cooling airflow Low speed net total capacity High speed cooling airflow High speed net total capacity Medium speed cooling airflow L Medium speed net total capacity Heating Information 14.20 btuh/watt 230 Volt 36177.00 Btu/hr 56.00 F 55.00 F 1806 cfm 1583 cfm 49617.00 Btu/hr Low speed cooling TESP Low speed net sensible capacity High speed cooling TESP High speed net sensible capacity Medium speed cooling TESP Medium speed net sensible capacity Low speed heating airflow Low speed heating leaving temperature High speed heating airflow Med / med-low speed heating Airflow Med low spd.heating leaving temperature Med-high speed heating airflow Low speed heating TESP High speed heating leaving temperature High speed heating TESP Med / med-low spd htg TESP Med-high spd heating TESP Med-high speed heating Ivg temperature 4/12/2013 Product Version 1,0 1.164 In H2O 0.895 In H2O 38673.00 Btu/hr Page 1 of 1 Page 1 of 1 13 SEER unit selection Refrigerant: Sound Transit Track Power Substation AC-4T 1ph No option selected Cooling Capacity: No option selected Electrical characteristics: No option selected 14 SF.UR Mil selectiQf Refrigerant: R-410A Pkg cooling 14 SEER Cooling capacity: 4 Ton 14 SEER Electrical characteristics: 208-230/1/60 AHRI data AHRI Capacity: 48500.00 Btu/hr SEER@ AHRI: 14.20 btuh/watt EER @ AHRI: 12.0 EER field applied voltage Field applied voltage: 230`Volt Design. system performance Design Airflow : 1400 cfm Design net total capacity: 48706.00 Btu/hr Design net sensible capacity: 36177.00 Btu/hr Design net latent capacity: 12529.00 Btu/hr Cooling LDB: 56.00 F Cooling LWB: 55.00 F IQOJ 2 Performance Medium speed cooling airflow: 1583 cfm Medium speed cooling TESP: 0.895 in H2O Medium speed net total capacity : 49617.00 Btu/hr Medium speed net sensible capacity : 38673.00 Btu/hr High speed cooling airflow: 1806 cfm High speed cooling TESP: 1.164 in H2O ikd+l tiiolaa1 Restat Inilppnation Ship Cede Ship cycle: Standard ship cycle ;accessories Roof curbs: Hinged filter access door. Thermostat: Roof curb Hinged filter access door No option selected Crankcase heater. Low ambient control: Crankcase heater Low ambient control kit Extended Warranties mpressor parts warranty: None arts only: None file://C:\Documents and Settings\jdella.CDI\Local Settings\Temp\7z0468.tmp\1.5-5 ton Pkgd. Cooling Roof... 8/29/2013 Sound Transit Track Power Substation TRANS' 4/12/2013 8:56:42 AM 1750 ■ V Cooling (Wet Coil), Horizontal Configuration AC4r 1ph r,o 333 403 45) AirflavREsistaee L l 1 _1 V 1 1 1 1 1 1 1 1 • 1 1 1 I A 1 rT T G A V I l I I 1 1 1 1 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Tatd tic RessuB(in H2C) v Q8 TOPSS Fan Curve / Acoustical Information Page: 1 Sound Transit Track Power Substation 1.5-5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1ph 4/12/2013 8:56:40 AM UNIT - TOP VIEW .71" V SECTION Y-Y TYPICAL (8) SIDES OF DOWNFLOW DUCT OPENINGS .70" 1 SECTION X-X TYPICAL (8) SIDES OF SIDEFLOW DUCT OPENINGS 14 11/16" 2 5/16" 33/8" - 1711/16" 1711/16"—j-=1215/18" UNIT - BACK AND PENETRATION VIEW 22 9/16" 37 3/8" CONDENSATE DRAIN FOR 3/4" FEMALE NPT UNIT - LEFT SIDE VIEW 24V ENTRY 14 118" 11 5118" 8 " lit, 4 5/8" 4 3/16" UNIT - BOTTOM PENETRATION VIEW NOTES: VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION 20 7/8" OWER ENTRY 1 1/8 DIA. HOLE 1 3/8" DIA. KNOCKOUT 1 5/8" DIA. KNOCKOUT OWER ENTRY 1 1/8" DIA. HOLE 1 3/8' DIA. KNOCKOUT 1 5/8" DIA. KNOCKOUT SINGLE POINT ENTRY 1 3/8" DIA. HOLE 1 5/8" DIA. KNOCKOUT 2 7/16" DIA. KNOCKOUT UNIT - RIGHT SIDE VIEW TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 1 Sound Transit Track Power Substation 1.5-5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1ph 4/12/2013 8:56:41 AM 'ELECTRICAL / GENERAL DATA POWER CONNECTION Model: 4TCY4048A1 Voltage Range: 208-230/1/60 Min. Circuit Ampacity: 33.8 Max. Circuit Breaker. 50.0 Prot. Rtg. Record: 50.0 EER/SEER 11.9/14.25 Noise Rating # : 72 COMPRESSOR Number. '1 Phase: 1 Rated Load Amps: 20.5 Locked Rotor Amps: 109.0 OUTDOOR MOTOR Number. Horsepower .25 Phase 1 Full Load Amps: 1.40 Locked Rotor Amps: 3.37 INDOOR MOTOR Number: Horsepower. Motor Speed (RPM): Phase Full Load Amps: Locked Rotor Amps: '1 .75 Variable 1 6.8 6.8 REFRIGERANT Type: Factory Charge Circuit #1: 'R-410A 8.2 HEATER Model: Voltage: Phase: Heater Capacity (Kw): Heater (Btu): # of Stages: Stage # 1: Stage # 2: MCA: MBS: SINGLE CIRCUIT POWER AMPACITY AND OVER CURRENT PROTECTION Single Power Entry Kit Minimum Circuit Ampacity Maximum Over -Current Device 1. Single Circuit Power fuses are supplied if required for unit and 1 or heater. 2. Wiring requirements if unit and electric heaters are operated from a single circuit using a single power entry kit. NOTES: UNIT ONLY 1. Rated in accordance with A.H.R.I. Standard 210/240. 2. Rated in accordance with D.O.E. test procedure. 3. Rated in accordance with A.H.R.I. Standard 270. ELECTRIC HEATER ACCESSORY ONLY 4. Any power supply and circuits must be wired and protected in accordance with local electrical codes. 5. The MCA values listed are for electric heater only. 6. The MCA values listed are for electric heater only. 7. Fieid wire must be rated at least 75t. 8. The HACR circuit breaker is for U.SA. Installations only. 9. For Canada Installations reference only. TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 2 • TRANE Sound Transit Track Power Substation 1.5-5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1 ph 4/12/2013 8:56:41 AM W1 W3 W4 CENTER OF GRAVITY UNIT WEIGHT CORNER WEIGHT CENTER OF GRAVITY SHIPPING NET W1 W2 W3 W4 A B '607.0 Ib 479.0 Ib '168.0 Ib 105.0 Ib 79.0 Ib '127.0 Ib • • '16 5116" '25"20" CLEARANCE TO COMBUSTIBLE MATERIAL RECOMMENDED SERVICE CLEARANCE BOTTOM 0 UNIT WITH O.A. DAMPER/ECON. WITH 2 POS. DAMPER BACK SIDE 1" BACK SIDE 12" 30" LEFT SIDE 6" LEFT SIDE 36" 42" RIGHT SIDE 6" RIGHT SIDE 24" FRONT SIDE 12" FRONT SIDE 30" TOP 36" LIFTING LUG KITS FOUR REUSABLE LUGS IN EACH KIT ALLOW UNITS TO BE EASILY LIFTED TO ROOFTOP INSTALLATIONS. THESE LUGS SNAP (NO SCREWS REQUIRED) INTO SLOTS IN THE UNIT DRIP LIP CHANNEL. TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 3 Sound Transit Track Power Substation TRAIN' 1.5.5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1ph 4/12/2013 8:56:41 AM 38 7/8" ISOMETRIC - ROOF CURB (UNINSULATED) ACCESSORY DRAWING 561/8 NOTES: VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION ATTENTIONII CURB DRAVNNGS ARE NOT INTENDED TO BE USED AS A BASIS TO CONSTRUCT, BUILD, MODIFY OR INSTALLATION.THE MANUFACTURER IS NOT RESPONSIBLE FOR THE UNAUTHORIZED USE OF THESE DRAWINGS AND EXPRESSLY DISCLAIMS ANY LIABILITY FOR DAMAGES RESULTING FROM SUCH UNAUTHORIZED USE SEE INSTALLER'S GUIDE 18-HE38D10-5. 14" 41 7/8" 3" 20" 19 1/2" SUPPLY 191/2" RETURN 4 3/4" b— TOP VIEW - ROOF CURB (UNINSULATED) —10 7/8"— ACCESSORY DRAWING TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 4 Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit Economizer rain hood Mist - lami- nator . Relief damper Roofcurb 000o._ o. 0 0 0 O 000 p 0100• 00000000000 00 0000 ®. *Outside air 1 dampers r Retum / air damp) ers Required filter kit, order separately Retum Duct Economizer Unit Application Models A BAYECON101A 4TC',WC',YC',DC' 20.125" '018-036 BAYECON102A 4TC',WC',YC', DC* 24.375" *042-060 BAYECON200,201A Horizontal Economizer and Rain Hood The drawings on this page are prepared by the manufacturer in order to provide detail re- garding job layout only.These drawings are not intended to be used as a basis to con- struct, build or modify the items depicted in the draw- ings. The manufacturer is not responsible for the unauthor- ized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. Economizer Duct Mixed Air Sensor Gaskets (2) �— Rain Hood Economizer A 8 C 0 E F BAYECON200AA 22" 20" 16.7/8" 15-11/16" 11-11/16" 15" BAYECON201AA 26" 22-21/32" 19" 17-11/16" 14-11/16" 21-3/8" 20 Sound Transit Track Power Substation lef TRANE 1.5.5 ton Pkgd. Cooling Rooftop Convert. R-410A Items: AC-4T 1ph Qty: 1 Tags: AC-4T 1ph 4/12/2013 8:56:41 AM PACKAGEDCOOLNOJELECTRIC HEAT UNIT r rr y —4 UNIT CONTROL BOX UMT HEATER AREA POLARZED PLUG ELECTRIC HEATER CONTROL BOX r r t- 48K) G I - - �tA> BRjy 1r — — � — —41C(BR)W2 I i i UNT LOW VOLTAGE AREAD)R 1'11 PH 1PHPH POWER POW131 GROUND WIRE 3PH 3PH POWER POWER UNIT HEATER CANNON FAN COMPRESSOR 1ST STAGE ELECTRIC HEAT 2ND STAGE ELECTRIC HEAT 24 VOLTS Ll i�OIY�IIR I=I TYPICAL THERMOSTAT NOTE 1,8 FIELD PROVIDED JUMPER NOTE6 NOTES: 1. FUSED DISCONNECT BITE, POWER WIRING AND GROUNDNG OF EQUIPMENT MUST COMPLY WITH CODES 2. BE SURE POWER SUPPLY AGREES Wmi EQUIPMENT AND HEATER NAMEPLATE. 3. LOW VOLTAGE WIRING TO BE 18 AWG MNIMUM CONDUCTOR. 4. SEE HEATER NAI,EPIATE FOR CURRENT RATING OF HEATER USED. 5. SEE UNIT AND HEATER DIAGRAM FOR ELECTRICAL CONNECTION DETALS. 6. JUMPER MOST BE CONNECTED BETWEEN 1 AND 2 FOR FAN TO OPERATE IN HEATING. 7. SOME THERMOSTATS PROVIDE THE 'G' SIGNALIN 1HE CODLING MODE ONLY. TO PROVIDE THE 'G' SGNAL IN THE HEAING MODE AN ACCESSORY RELAY IS REQUIRED, SEE FIG.3 FOR PROPER CONFECTIONS. 8. FOR COOLJNG ONLY OMIT THE ELECTRIC HEATER. ASSOCIATED POWER WIRES, A8D THE W SIGNAL THERMOSTAT WIRE. 9. FIG.4 DEMONSTRATES CONNECTION OF THE TWO STAGE ELECTRIC HEAT THERMOSTAT ACCESSORY ONLY. FOR FURTHER UNT CONNECTION DETAILS REFER TO THE OTHER FIGURES, 10. THE 41A(13R) WIRE IS FIRST STAGE ELECTRIC HEAT. IF THE ELECTRIC HEATER ACCESSORY HAS TWO HEATING STAGES THE 41 C(ER) WIRE IS SECONDSTAGE ELECTRIC HEAT. FIG. 1 SINGLE POWER ENTRY ACCESSORY CONFECTIONS TO ECONOMZER FFCTD FR0 WIRES LO YP INSTALLED (- FIG2 ECONOMIZER ACCESSORY CONFECTIONS VICED D ED (NOTAPPUCAMLE TO THETCM-F MODELS) i UNIT CONTROL BOX UNIT HEATER AF€A — TOCOMPR. —'— CONTACTOR FACTORY FRONDED FIELD CONNECTED WIRES f \� ELECTRIC HEATER CONTROL_4 ox ( _� i 36E 8 366(BL) B 44E(YL) �� I 47E(Bp 47A(3K) G r , — rMOryR '� 44A(YL) Y rr _� UFUSES HEATER 1 11 1 ~ FUSES I rr 44A(BRIWI UNIT LOW VOLTAGE AREA I I I r-- R— 4IC(BR)W2 11 I r -� 35A(RO) R 1 ACCESSORY KIT �_ �— 11 1 I 11 I T UN ILOW AREA i I I I I FIELD RED I I i I ! INSTALLEDM'E 4'1 WIRE ND IP POWERI L� 3 PH POWER SINGLEPOWER ENTRY Iv ton 4.JJ-ra-Rl 2-ST TYPICAL2STAGE THERMOSTAT FIG.3 AUTO CHANGEOVER THERMOSTAT CONNECTIONS NOTE7 i-14 FIG. 4 TWO STAGE ELECTRIC HEATCONNECTKINS 360(BL) 8 r 2� 47A(BK) G UNRLOW VOLTAGE AREA— NOTE 10 — —R 41A(8PoW1 r r— — — —R— 41C(BR) W2 J I- j 44A(YL) Y r - p 41A(BR)W1 1 — fl` JL— 41C(BR)W2 UNIT LOW VOLTAGE ALEA r— I —`� 1 I I r I I 35A(RD)R i I I III �lt I r- — — —1 — i BAY24X1342 II I s n c n vn nc FIELD 1_ -I_ _.I — — — — TYPICALTHERMOSTAT JJUEIPER D I I rI �— —J 1 I FIELD INSTALLED AN JUMPER O0©00 TYPICAL THERMOSTAT I NT ER-COMPONTENT W1RING 24V. FACTORY LINE V. WIRING 24V. FIELD LINE V. WIRING WIRE COLOR DESIGNATION ABBR COLOR ABBR COLOR 8K BLACK PR PURPLE BL BLUE RD RED 8R BROWN WH WMRE GR GREEN YL YELLOW OR ORANGE TOPSS Dimension Drawing ALL WEIGHTS AND DIMENSIONS ARE APPROXIMATE. Page: 5 Design Weather Parameters & MSHGs ST 7019 2013-018 CDi Engineers 08/29/2013 04:53PM Design Parameters: City Name __. Location Latitude .._.._ ..:.___ Longitude Elevation ... Summer Design Dry -Bulb . Summer Coincident Wet -Bulb Summer Daily Range Winter Design Dry -Bulb . .. Winter Design Wet -Bulb ............... . Atmospheric Clearness Number Average Ground Reflectance ... Soil Conductivity __ .. Local Time Zone (GMT +/- N hours) Consider Daylight Savings Time Simulation Weather Data Current Data is . Design Cooling Months Design Day Maximum Solar Heat Gains (The MSHG values are expressed in BTU/(hr-ft2) ) __Seattle IAP Washington __ 47.5 Deg. .... 122.3 Deg. 449.0 ft 85.0 °F 65.0 °F 18.3 °F 23.0 °F .19.2 °F 1.05 0.20 0.800 BTU/(hr-ft-°F) 8.0 hours No noneN/A 2001 ASHRAE Handbook January to December Month N NNE NE ENE E ESE SE SSE S January 16.1 16.1 16.1 53.6 129.0 183.4 230.6 251.9 257.9 February 21.4 21.4 36.9 112.4 175.7 229.5 253.9 260.9 262.5 March 27.1 27.1 91.8 159.2 217.2 242.8 253.0 243.7 238.0 April 33.0 68.6 137.1 195.3 225.5 239.1 225.9 204.4 192.1 May 37.3 105.1 162.3 210.6 229.9 225.1 199.4 170.1 154.1 June 51.1 117.6 171.4 213.7 226.9 216.7 186.9 154.0 137.4 July 39.4 104.2 161.3 207.5 222.7 220.4 195.6 165.7 151.0 August 34.8 65.4 134.3 187.4 219.3 230.1 218.4 197.6 186.3 September 28.2 28.2 86.3 145.2 203.9 232.3 242.6 235.6 227.9 October 22.1 22.1 36.4 105.4 171.4 216.2 245.2 253.6 252.2 November 16.3 16.3 16.3 56.6 123.7 184.3 224.4 244.6 251.3 December 13.7 13.7 13.7 34.5 105.1 162.2 212.5 238.1 245.0 Month SSW SW WSW W WNW NW NNW HOR Mult January 251.9 227.1 188.2 121.9 59.5 16.1 16.1 92.5 1.00 February 262.5 255.6 227.5 179.4 105.7 40.2 21.4 147.6 1.00 March 244.1 251.9 247.4 210.6 163.3 87.7 27.1 199.6 1.00 April 204.0 224.1 238.5 228.6 194.9 132.9 70.0 238.0 1.00 May 169.6 197.8 223.8 231.1 208.5 165.6 103.6 259.3 1.00 June 152.9 185.9 214.0 228.2 209.8 175.3 113.9 265.4 1.00 July 164.4 194.2 217.4 226.5 202.6 164.4 101.1 257.6 1.00 August 197.1 216.1 229.9 220.5 187.9 129.3 68.8 234.8 1.00 September 235.7 242.6 232.9 203.5 146.7 86.2 28.2 191.4 1.00 October 252.2 242.3 219.1 167.3 108.3 30.0 22.1 144.2 1.00 November 245.2 225.7 182.6 125.7 52.6 16.3 16.3 91.1 1.00 December 235.2 212.0 163.5 105.1 33.6 13.7 13.7 69.9 1.00 ult. = User -defined solar multiplier factor. Hourly Analysis Program v4.60 Page 1 of 1 Schedule Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 24/7 Sched (Fractional) Hourly Profiles: 1:Profile One Hour 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Value 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 Assignments: Design Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 1 1 1 1 1 1 1 1 1 1 1 1 Monday 1 1 1 1 1 1 1 1 1 1 1 1 Tuesday 1 1 1 1 1 1 1 1 1 1 1 1 Wednesday 1 1 1 1 1 1 1 1 1 1 1 1 Thursday 1 1 1 1 1 1 1 1 1 1 1 1 Friday 1 1 1 1 1 1 1 1 1 1 1 1 Saturday 1 1 1 1 1 1 1 1 1 1 1 1 Sunday 1 1 1 1 1 1 1 1 1 1 1 1 Holiday 1 1 1 1 1 1 1 1 1 1 1 1 Hourly Analysis Program v4.60 Page 1 of 1 Wall Constructions ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM Signal House Wall Walt Details Outside Surface Color Absorptivity ........................ Overall U-Value Wail Layers Details (Inside to Outside Dark 0.900 0.080 BTU/(hr-ft2-°F) Layers Thickness in Density Ib/ft' Specific Ht. BTU / (lb - °F) R-Value (hr-ft2-°F)IBTU Weight Ib/ft2 Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 2" batt insulation 2.000 0.5 0.20 6.41026 0.1 1" Poly insulation 1.000 2.0 0.22 5.00000 0.2 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 3.067 - 12.42847 3.0 TPSS Wall Wall Details Outside Surface Color Absorptivity Overall U-Value Wall Layers Details (Inside to Outside Dark 0.900 0.094 BTU/(hr-ft2-°F) Layers Thickness in Density ib/ft' Specific Ht. BTU / (lb - °F) R-Value (hr-ft2 °F)/BTU Weight Ib/ft2 Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 3" batt insulation 3.000 0.5 0.20 9.61538 0.1 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 3.067 - 10.63359 2.9 Hourly Analysis Program v4.60 Page 1 of 1 Roof Constructions ST T019 2013-018 CDi Engineers 08/29/2013 04:54PM Signal House Metal Roof Roof Details Outside Surface Color Absorptivity Overall U-Value ._. Roof Lavers Details (Inside to Outside Medium 0.675 0.080 BTU/(hr-ft2 °F) Layers Thickness in Density Ib/ft' Specific Ht. BTU / (lb - °F) R-Value (hr-ft'--°F)/BTU Weight Ib/ft' Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 Poly rigid insulation 1.000 2.0 0.22 5.00000 0.2 batt insulation 2.000 0.5 0.20 6.41026 0.1 22 gage steel deck 0.034 489.0 0.12 0.00011 1.4 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 3.067 - 12.42847 3.0 TPSS Metal Roof Roof Details Outside Surface Color Absorptivity Overall U-Value Roof Layers Details (Inside to Outside) Medium 0.675 0.094 BTU/(hr-ft'-°F) Layers Thickness in Density Ib/ft3 Specific Ht. BTU / (lb - °F) R-Value (hr-ft2-°F)/BTU Weight Ib/ft' Inside surface resistance 0.000 0.0 0.00 0.68500 0.0 22 gage steel panel 0.034 489.0 0.12 0.00011 1.4 batt insulation 3.000 0.5 0.20 9.61538 0.1 22 gage steel deck 0.034 489.0 0.12 0.00011 1.4 Outside surface resistance 0.000 0.0 0.00 0.33300 0.0 Totals 3.067 - 10.63359 2.9 Hourly Analysis Program v4.60 Page 1 of 1 Door Constructions ST TO19 2013-018 CDi Engineers 08/29/2013 04:54PM Double Metal Door Door Details: Gross Area _.. ... Door U-Value 48.0 ft2 0.652 BTU/(hr-ft2-°F) Glass Details: Glass Area .., 0.0 ft2 Glass U-Value _.. ,._ . 0.580 BTU/(hr-ft2-°F) Glass Shade Coefficient 0.880 Glass Shaded All Day? ....... No Single Metal Door Door Details: Gross Area Door U-Value 24.0 ft2 0.652 BTU/(hr-ft2-°F) Glass Details: Glass Area ... .... 0.0 ft2 Glass U-Value 0.580 BTU/(hr-ft2-°F) Glass Shade Coefficient . 0.880 Glass Shaded All Day? ... .._ No Hourly Analysis Program v4.60 Page 1 of 1 Space Input Data ST T019 2013-018 CDi Engineers 08/29/2013 04:53PM Signal Hse e-w 1. General Details: Floor Area ,... .,.. . 200.0 Avg. Ceiling Height 9.5 Building Weight ..._ .. _._ ._ __ 130.0 1.1. OA Ventilation Requirements: Space Usage . User -Defined OA Requirement 1 , _ 0.0 OA Requirement 2 0.00 Space Usage Defaults .... _... ASHRAE Std 62.1-2007 ft2 ft Ib/ft2 CFM/person CFM/ft2 2. Internals: 2.1. Overhead Lighting: Fixture Type Recessed (Unvented) Wattage 1.50 W/ft2 Ballast Multiplier 1.00 Schedule 24/7 Sched 2.2. Task Lighting: Wattage Schedule 0.00 W/ftz None 2.3. Electrical Equipment: Wattage 39.50 W/ftz Schedule 3. Walls, Windows, Doors: 24/7 Sched 2.4. People: Occupancy Activity Level .,.. Sensible ..,..... Latent Schedule 2.5. Miscellaneous Loads: Sensible . Schedule Latent Schedule ... ... .... Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 145.0 0 0 0 S 72.5 0 0 0 E 145.0 0 0 1 N 72.5 0 0 0 3.1. Construction Types Wall Type 3.2. Construction Types Wall Type 3.3. Construction Types Wall Type Door Type 3.4. Construction Types Wall Type 4. Roofs, Skylights: for Exposure W Signal House Wall for Exposure S for Exposure E for Exposure N Signal House Wall Signal House Wall Single Metal Door Signal House Wall Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 2O0.0 0 1 0 4.1. Construction Types for Exposure H Roof Type Signal House Metal Roof 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 CFM 0.00 CFM _...0.0 Person User defined 250.0 BTU/hr/person 200.0 BTU/hdperson None 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v4.60 Page 1 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 2 of 10 Space Input Data ST T019 2013-018 CDi Engineers 08/29/2013 04:53PM Signal Hse n-s 1. General Details: Floor Area .... ,_. Avg. Ceiling Height Building Weight 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 .. ... ... 0.0 OA Requirement 2 ..... .._..... _.... „ 0.00 Space Usage Defaults ASHRAE Std 62.1-2007 2. Intemals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 200.0 ft2 .. . 9.5 ft 130.0 lb/ft2 CFM/person CFM/ft2 Recessed(Unvented) 1.50 W/ft2 1.00 24/7 Sched 0.00 W/ft2 None 45.05 W/ft2 24/7 Sched 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent Schedule Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 72.5 0 0 0 S 145.0 0 0 0 E 72.5 0 0 1 N 145.0 0 0 0 3.1. Construction Types Wall Type 3.2. Construction Types Wall Type 3.3. Construction Types Wall Type Door Type 3.4. Construction Types Wall Type 4. Roofs, Skylights: for Exposure W for Exposure S for Exposure E for Exposure N Signal House Wall Signal House Wall Signal House Wail Single Metal Door Signal House Wall Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 2O0.0 0 0 4.1. Construction Types for Exposure H Roof Type .. Signal House Metal Roof 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 CFM 0.00 CFM 0.0 Person User defined .250.0 BTU/hr/person .,. 200.0 BTU/hr/person None 0 BTU/hr ,.. None 0 BTU/hr None Hourly Analysis Program v4.60 Page 3 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 4 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM Small Signal House 1. General Details: Floor Area Avg. Ceiling Height .,.._ Building Weight 1.1. OA Ventilation Requirements: Space Usage .. OA Requirement 1 OA Requirement 2 Space Usage Defaults 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage .. Ballast Multiplier Schedule 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: . 36.0 7.5 130.0 ft2 ft lb/ft2 User -Defined .. 0.0 CFM/person 0.00 CFM/ft2 ASHRAE Std 62.1-2007 Recessed (Unvented) 400.0 Watts 1.00 24/7 Sched 0.00 W/ft2 None „5004.0 Watts 24/7 Sched 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent .. Schedule Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 45.0 0 0 0 S 45.0 0 0 0 E 45.0 0 0 1 N 45.0 0 0 0 3.1. Construction Types for Exposure W Wall Type 3.2. Construction Types for Exposure S Wall Type 3.3. Construction Types for Exposure E Wall Type Door Type 3.4. Construction Types for Exposure N Wall Type 4. Roofs, Skylights: Signal House Wall Signal House Wall Signal House Wall Single Metal Door Signal House Wall Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 36.0 0 0 4.1. Construction Types for Exposure H Roof Type .., Signal House Metal Roof 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. 0.00 CFM 0.00 CFM 0.00 CFM 0.0 Person User defined ....250.0 BTU/hr/person 200.0 BTU/hr/person None 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v4.60 Page 5 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 6 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM TPSS e-w 1. General Details: Floor Area . ... 790.0 ft2 Avg. Ceiling Height ... 9.6 ft Building Weight 130.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage ... ... User -Defined OA Requirement 1 0.0 CFM/person OA Requirement 2 0.00 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2007 2. Internals: 2.1. Overhead Lighting: Fixture Type Wattage Ballast Multiplier .... Schedule _. 2.2. Task Lighting: Wattage .,. Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: ... Recessed (Unvented) 1.50 W/ft2 .......: 1.00 24/7 Sched 0.00 W/ft2 None .32230.0 Watts 24/7 Sched 2.4. People: Occupancy Activity Level Sensible Latent Schedule 2.5. Miscellaneous Loads: Sensible Schedule Latent ... .,. Schedule Exp. Wail Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 470.0 0 0 0 S 138.0 0 0 1 E 470.0 0 0 0 N 138.0 0 0 2 3.1. Construction Types Wall Type 3.2. Construction Types Wall Type ,.. ... Door Type 3.3. Construction Types Wall Type 3.4. Construction Types Wall Type Door Type 4. Roofs, Skylights: for Exposure W . TPSS Wall for Exposure S _. TPSS Wall Single Metal Door for Exposure E for Exposure N TPSS Wail . ...TPSS Wall Double Metal Door Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 790.0 0 0 4.1. Construction Types for Exposure H Roof Type 5. Infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. TPSS Metal Roof 0.00 CFM/ft2 ,.,...0.00 CFM 0.00 CFM 0.0 Person User defined 250.0 BTU/hr/person 200.0 BTU/hr/person None 0 BTU/hr None 0 BTU/hr None Hourly Analysis Program v4.60 Page 7 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 8 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM TPSS n-s 1. General Details: Floor Area 790.0 ft2 Avg. Ceiling Height ._. 9.6 ft Building Weight 130.0 lb/ft2 1.1. OA Ventilation Requirements: Space Usage User -Defined OA Requirement 1 ... .. 0.0 CFM/person OA Requirement 2 0.00 CFM/ft2 Space Usage Defaults ASHRAE Std 62.1-2007 2. Internals: 2.1. Overhead Lighting: 2.4. People: Fixture Type Recessed (Unvented) Occupancy .._.._...._.... 0.0 Person Wattage __..... __ 1.50 W/ft2 Activity Level User defined Ballast Multiplier 1.00 Sensible .._.... ...._250.0 BTU/hr/person Schedule .. 24/7 Sched Latent .... ... 200.0 BTU/hr/person Schedule None 2.2. Task Lighting: Wattage Schedule 2.3. Electrical Equipment: Wattage Schedule 3. Walls, Windows, Doors: 2.5. Miscellaneous Loads: 0.00 W/ft2 Sensible 0 BTU/hr None Schedule ., None Latent ... 0 BTU/hr Schedule None 32230.0 Watts 24/7 Sched Exp. Wall Gross Area (ft2) Window 1 Qty. Window 2 Qty. Door 1 Qty. W 138.0 0 0 1 S 518.0 0 0 0 E 138.0 0 0 1 N 518.0 0 0 0 3.1. Construction Types for Exposure W Wall Type TPSS Wall Door Type Single Metal Door 3.2. Construction Types for Exposure S Wall Type 3.3. Construction Types for Exposure E Wall Type Door Type ...... TPSS WaII TPSS Wall ...Double Metal Door 3.4. Construction Types for Exposure N Wall Type 4. Roofs, Skylights: TPSS Wall Exp. Roof Gross Area (ft2) Roof Slope (deg.) Skylight Qty. H 790.0 0 0 4.1. Construction Types for Exposure H Roof Type 5. infiltration: Design Cooling Design Heating Energy Analysis Infiltration occurs at all hours. TPSS Metal Roof 0.00 CFM/ft2 0.00 CFM 0.00 CFM Hourly Analysis Program v4.60 Page 9 of 10 Space Input Data ST TO19 2013-018 CDi Engineers 08/29/2013 04:53PM 6. Floors: Type Floor Above Conditioned Space (No additional input required for this floor type). 7. Partitions: (No partition data). Hourly Analysis Program v4.60 Page 10 of 10 Signal House Split Sys e-w Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:55PM 1. General Details: Air System Name Equipment Type Air System Type Number of zones 2. System Components: Ventilation Air Data: Airflow Control .,, ..._.... , Ventilation Sizing Method Unocc. Damper Position _, Damper Leak Rate Outdoor Air CO2 Level Signal House Split Sys e-w ... Split AHU Single Zone CAV 1 Constant Ventilation Airflow Sum of Space OA Airflows 400 ppm Central Cooling Data: Supply Air Temperature . .... ... ... 58.0 °F Coil Bypass Factor ._ 0.100 Cooling Source , . Air -Cooled DX Schedule __JFMAMJJASOND Capacity Control .. Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 95.0 °F Heating Source Electric Resistance Schedule JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type .. Forward Curved Configuration ___ Draw-thru Fan Performance 0.00 in wg Overall Efficiency ... .... . . . 54 % Fan Control 1-speed fan, cooling and heating Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Return Air Via 3. Zone Components: Space Assignments: . 0 Ducted Return Zone 1: Signal House Zn Signal Hse e-w x1 Thermostats and Zone Data: Zone All Cooling T-stat: Occ. 80.0 °F Cooling T-stat: Unocc. . 80.0 °F Heating T-stat: Occ. • 70.0 °F Heating T-stat: Unocc. 65.0 °F T-stat Throttling Range 1.50 °F Diversity Factor 100 % Direct Exhaust Airflow ... 0.0 CFM Direct Exhaust Fan kW ... ... 0.0 kW Thermostat Schedule ... Sample Schedule Unoccupied Cooling is .. Available Supply Terminals Data: Zone ... All Terminal Type Diffuser Minimum Airflow 0.00 CFM/person Zone Heating Units: Zone All Zone Heating Unit Type None Hourly Analysis Program v4.60 Page 1 of 2 Signal House Split Sys e-w Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:55PM Zone Unit Heat Source Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Cooling Supply Temperature Supply Fan Airflow _. Ventilation Airflow Heating Supply Temperature Hydronic Sizing Specifications: Chilled Water Delta-T Hot Water Delta-T Safety Factors: Cooling Sensible Cooling Latent Heating Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method .... Electric Resistance JFMAMJJASOND 58.0 °F 1333.0 CFM 0.0 CFM 95.0 °F 10.0 °F 20.0 °F . 5 % 0 0 Sum of space airflow rates Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 1333.0 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load . .31.0 MBH Design OAT 95.0 °F Equipment Sizing Auto -Sized Capacity Oversizing Factor 0 % ARI Performance Rating 11.000 EER DX System Configuration 2-stage compression, separate circuits Conventional Cutoff OAT 55.0 °F Low Temperature Operation .. Used Low Temperature Cutoff OAT 0.0 °F Hourly Analysis Program v4.60 Page 2 of 2 Air System Sizing Summary for Signal House Split Sys e-w Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:57PM Air System Information Air System Name Signal House Split Sys e-w Equipment Class ... ._, .. SPLT AHU Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM ._ .......... Sum of space airflow rates Space CFM Individual peak space Toads Central Cooling Coil Sizing Data Total coil load ... Total coil load.. Sensible coil load Coil CFM at Jul 1500 _. Max block CFM .... Sum of peak zone CFM Sensible heat ratio __ ft2/Ton BTU/(hr-ft2) ... Water flow @ 10.0 °F rise 31.0 1333 1333 ,,... 1333 __ 1.000 77.3 155.2 N/A Tons MBH MBH CFM CFM CFM Central Heating Coil Sizing Data Max coil load... 3.2 MBH Coil CFM at Des Htg 1333 CFM Max coil CFM . 1333 CFM Water flow @ 20.0 °F drop .. N/A Supply Fan Sizing Data Actual max CFM Standard CFM Actual max CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM CFM/ft2... ,...... 1333 CFM 1312 CFM _ 6.66 CFM/ft2 0 CFM ,, 0.00 CFM/ft2 Number of zones Floor Area Location Calculation Months .. Sizing Data 200.0 ft2 . Seattle IAP, Washington Load occurs at _ OADB/WB ...... Entering DB / WB Leaving DB / WB Coil ADP . _.. _. Bypass Factor Resulting RH _. _. Design supply temp. Zone T-stat Check Max zone temperature deviation Load occurs at BTU/(hr-fta) Ent. DB / Lvg DB Fan motor BHP Fan motor kW Fan static _... ...... CFM/person ... .,...Jan to Dec ...Calculated Jul 1500 85.0/65.0 81.6 / 48.7 ,.. 59.7 / 37.9 .,, 57.2 0.100 0 ,. 58.0 0 of 1 0.1 °F °F °F °F ok °F OK °F Des Htg 15.9 70.4/72.7 °F 0.00 BHP 0.00 kW 0.00 in wg 0.00 CFM/person Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Signal House Split Sys e-w Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:57PM Air System Information Air System Name ._ .. Signal House Split Sys e-w Equipment Class ... SPLT AHU Air System Type .,. ,. SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM.._.._......_.__. ....: Sum of space airflow rates Space CFM .....__ ..Individual peak space loads Zone Sizing Data Number of zones Floor Area ._. __ .. 200.0 ft2 Location .... Seattle IAP, Washington Calculation Months ... Sizing Data 1 .Jan to Dec ,..... Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (W) Zone CFM/ft2 Signal House Zn 31.2 1333 1333 Jul 1500 3.0 200.0 6.66 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Signal House Zn Signal Hse e-w 1 31.2 Jul 1500 1333 3.0 200.0 6.66 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Signal House Split Sys e-w Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:57PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 411.ft2 1055 - 411 ft2 1554 - Roof Transmission 200 ft2 621 - 200 ft2 756 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft2 25 - 24 ft2 735 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 300 W 1023 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 7900 W 26952 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 1484 0 0% 0 0 » Total Zone Loads - 31161 0 - 3046 0 Zone Conditioning - 31031 0 - 3184 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 1333 CFM 0 - 1333 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 1333 CFM 0 - 1333 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 31031 0 - 3184 0 Central Cooling Coil - 31031 0 - 0 0 Central Heating Coil - 0 - - 3184 - » Total Conditioning - 31031 0 - 3184 0 Key: Positive values are clg loads Negative values are htg Toads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Signal House Split Sys e-w Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:57PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE " Signal Hse a-w' IN ZONE " Signal House Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F OCCUPIED T-STAT 80.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft' - - Wall Transmission 411 ft' 1055 - 411 ft' 1554 - Roof Transmission 200 ft' 621 - 200 ft' 756 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft' 25 - 24 ft' 735 - Floor Transmission 0 ft' 0 - 0 ft' 0 - Partitions 0 ft2 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 300 W 1023 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 7900 W 26952 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 1484 0 0% 0 0 » Total Zone Loads - 31161 0 - 3046 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " Signal Hse a-w " IN ZONE " Signal House Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft') (BTU/(hr-ft' °F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 145 0.080 - 637 - 548 S EXPOSURE WALL 73 0.080 - 183 - 274 E EXPOSURE WALL 121 0.080 - 164 - 458 DOOR 24 0.652 - 25 - 735 N EXPOSURE WALL 73 0.080 - 71 - 274 H EXPOSURE ROOF 200 0,080 - 621 - 756 Hourly Analysis Program v4.60 Page 4 of 4 Signal House Split Sys n-s Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM 1. General Details: Air System Name Equipment Type Air System Type Number of zones Signal House Split Sys n-s Split AHU Single Zone CAV 1 2. System Components; Ventilation Air Data: Airflow Control ...__ .. __. . ..__ Constant Ventilation Airflow Ventilation Sizing Method .._Sum of Space OA Airflows Unocc. Damper Position Closed Damper Leak Rate _.. 0 % Outdoor Air CO2 Level 400 ppm Central Cooling Data: Supply Air Temperature 58.0 °F Coil Bypass Factor .. 0.100 Cooling Source Air -Cooled DX Schedule JFMAMJJASOND Capacity Control . Cycled or Staged Capacity - Fan On Central Heating Data: Supply Temperature 95.0 °F Heating Source Electric Resistance Schedule ... JFMAMJJASOND Capacity Control Cycled or Staged Capacity - Fan On Supply Fan Data: Fan Type Forward Curved Configuration Draw-thru Fan Performance . __. 0.00 in wg Overall Efficiency 54 % Fan Control ... 1-speed fan, cooling and heating Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Return Air Via 3. Zone Components: Space Assignments: 0 % 0 % .._.._ . . Ducted Return Zone 1: Signal House Zn Signal Hse n-s x1 Thermostats and Zone Data: Zone All Cooling T-stat: Occ. ,.. 80.0 °F Cooling T-stat: Unocc. 80.0 °F Heating T-stat: Occ. 70.0 °F Heating T-stat: Unocc. 65.0 °F T-stat Throttling Range 1.50 °F Diversity Factor 100 % Direct Exhaust Airflow _.. 0.0 CFM Direct Exhaust Fan kW . . 0.0 kW Thermostat Schedule ... ... Sample Schedule Unoccupied Cooling is Available Supply Terminals Data: Zone All Terminal Type Diffuser Minimum Airflow _. 0.00 CFM/person Zone Heating Units: Zone ... All Zone Heating Unit Type None Hourly Analysis Program v4.60 Page 1 of 2 Signal House Split Sys n-s Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Zone Unit Heat Source ... Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Cooling Supply Temperature Supply Fan Airflow Ventilation Airflow ... Heating Supply Temperature Hydronic Sizing Specifications: Chilled Water Delta-T _. Hot Water Delta-T ..... Safety Factors: Cooling Sensible Cooling Latent Heating .._,. Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method Electric Resistance JFMAMJJASOND 58.0 °F 1499.5 CFM 0.0 CFM 95.0 °F 10.0 °F .., 20.0 °F 5 % 0 % Sum of space airflow rates Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 1499.5 - - 5. Equipment Data Central Cooling Unit - Air -Cooled DX Estimated Maximum Load Design OAT. Equipment Sizing .. Capacity Oversizing Factor ARI Performance Rating DX System Configuration 2-stage compression, separate circuits Conventional Cutoff OAT Low Temperature Operation Low Temperature Cutoff OAT 34.9 MBH 95.0 °F Auto -Sized 0 11.000 EER °F Used 0.0 °F Hourly Analysis Program v4.60 Page 2 of 2 Air System Sizing Summary for Signal House Split Sys n-s Project Name: ST TO19 2013-018 08/29/2013 Prepared by: CDi Engineers 04:59PM Air System Information Air System Name .__ Signal House Split Sys n-s Equipment Class ..... _ SPLT AHU Air System Type _. SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM. ... ,_ Sum of space airflow rates Space CFM Individual peak space loads Number of zones _... Floor Area Location 1 200.0 ft2 Seattle IAP, Washington Calculation Months .... Jan to Dec Sizing Data ...... Calculated Central Cooling Coil Sizing Data Total coil load .,, ... 2.9 Tons Load occurs at ., . Jul 1400 Total coil load .,. ... .,_ 34.9 MBH OA DB / WB 84.5 / 64.8 °F Sensible coil load 34.9 MBH Entering DB / WB .... .. . 81.6 / 48.8 °F Coil CFM at Jul 1400 . ... 1500 CFM Leaving DB / WB 59.7 / 38.0 °F Max block CFM. 1500 CFM Coil ADP . 57.3 °F Sum of peak zone CFM 1500 CFM Bypass Factor _. 0.100 Sensible heat ratio .___ . 1.000 Resulting RH 0 % ft2/Ton .........,. _. 68.8 Design supply temp. 58.0 °F BTU/(hr-ft2) 174.5 Zone T-stat Check 0 of 1 OK Water flow @ 10.0 °F rise . N/A Max zone temperature deviation ....... . 0.1 °F Central Heating Coil Sizing Data Max coil Toad...... .. 3.4 MBH Load occurs at Coil CFM at Des Htg .. 1500 CFM BTU/(hr-ft2) Max coil CFM .... . _.. 1500 CFM Ent. DB / Lvg DB Water flow @ 20.0 °F drop . _,. N/A Supply Fan Sizing Data Actual max CFM Standard CFM Actual max CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM CFM/ft2 _ 1500 CFM 1475 CFM 7.50 CFM/ft2 0 CFM .. ..... 0.00 CFM/ft2 Fan motor BHP Fan motor kW Fan static Des Htg 17.0 70.6 / 72.7 °F 0.00 BHP 0.00 kW 0.00 in wg CFM/person ._ _. 0.00 CFM/person Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Signal House Split Sys n-s Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Air System Information Air System Name ....Signal House Split Sys n-s Equipment Class .. SPLT AHU Air System Type ..,. S2CAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Space CFM Zone Sizing Data Number of zones Floor Area Location .............. Sum of space airflow rates Calculation Months Individual peak space Toads Sizing Data 1 200.0 ft2 Seattle IAP, Washington Jan to Dec Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft2 Signal House Zn 35.1 1500 1500 Jul 1400 3.0 200.0 7.50 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Signal House Zn Signal Hse n-s 1 35.1 Jul 1400 1500 3.0 200.0 7.50 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Signal House Split Sys n-s Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1400 COOLING OA DB / WB 84.5 °F / 64.8 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window 8 Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 411 ft2 914 - 411 ft2 1554 - Roof Transmission 200 ft2 692 - 200 ft2 756 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft2 18 - 24 ft2 735 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 300 W 1023 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 9010 W 30739 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 1669 0 0% 0 0 » Total Zone Loads - 35055 0 - 3046 0 Zone Conditioning - 34895 0 - 3400 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 1500 CFM 0 - 1500 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 1500 CFM 0 - 1500 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 34895 0 - 3400 0 Central Cooling Coil - 34895 0 - 0 0 Central Heating Coil - 0 - - 3400 - » Total Conditioning - 34895 0 - 3400 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Signal House Split Sys n-s Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE " Signal Hse n-s ' IN ZONE " Signal House Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1400 COOLING OADB/WB 84.5°F/64.8°F OCCUPIED T-STAT 80.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTUlhr) (BTU/hr) Details (BTU/hr) (BTUIhr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 411 ft2 914 - 411 ft2 1554 - Roof Transmission 200 ft2 692 - 200 ft2 756 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft2 18 - 24 ft2 735 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft' 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 300 W 1023 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 9010 W 30739 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 1669 0 0% 0 0 » Total Zone Loads - 35055 0 - 3046 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " Signal Hse n-s " IN ZONE " Signal House Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr-ft2-°F)) Coeff. (BTU/hr) (BTU/hr) (BTUIhr) W EXPOSURE WALL 73 0.080 - 255 - 274 S EXPOSURE WALL 145 0.080 - 448 - 548 E EXPOSURE WALL 49 0.080 - 67 - 183 DOOR 24 0.652 - 18 - 735 N EXPOSURE WALL 145 0.080 - 143 - 548 H EXPOSURE ROOF 200 0.080 - 692 - 756 Hourly Analysis Program v4.60 Page 4 of 4 Signal House thru wall Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM 1. General Details: Air System Name Equipment Type Air System Type ... Number of zones Signal House thru wall Undefined .. Single Zone CAV 1 2. System Components: Ventilation Air Data: Airflow Control Constant Ventilation Airflow Ventilation Sizing Method ...Sum of Space OA Airflows Unocc. Damper Position _ __ Closed Damper Leak Rate . . .. 0 % Outdoor Air CO2 Level ... ppm Supply Fan Data: Fan Type Forward Curved Configuration .. Draw-thru 0.00 in wg .. 54 % Fan Performance Overall Efficiency Duct System Data: Supply Duct Data: Duct Heat Gain .... Duct Leakage Return Duct or Plenum Data: Return Air Via 3. Zone Components: Space Assignments: .0 % 0 % Ducted Return Zone 1: Signal House Zn Small Signal House x1 Thermostats and Zone Data: Zone . ._. Cooling T-stat: Occ. Cooling T-stat: Unocc. Heating T-stat: Occ. Heating T-stat: Unocc. T-stat Throttling Range Diversity Factor Direct Exhaust Airflow.. Direct Exhaust Fan kW All 80.0 °F 80.0 °F 70.0 °F _ 65.0 °F 1.50 °F 100 % __._......0.0 CFM 0.0 kW Thermostat Schedule . Sample Schedule Unoccupied Cooling is _. ._.... Available Supply Terminals Data: Zone _ ..... All Terminal Type ,_. ,.. Diffuser Minimum Airflow 0.00 CFM/person Zone Heating Units: Zone All Zone Heating Unit Type None Zone Unit Heat Source Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Supply Fan Airflow Ventilation Airflow .. Hydronic Sizing Specifications: Chilled Water Delta-T Hot Water Delta-T .Any JFMAM.JJASOND 851.5 CFM 0.0 CFM 10.0 °F 20.0 °F Safety Factors: Cooling Sensible 5 % Hourly Analysis Program v4.60 Page 1 of 2 Signal House thru wall Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Cooling Latent ... Heating Zone Sizing Data: Zone Airflow Sizing Method . . Space Airflow Sizing Method 0 Sum of space airflow rates Individual peak space loads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 851.5 - - 5. Equipment Data No Equipment Data required for this system. Hourly Analysis Program v4.80 Page 2 of 2 Air System Sizing Summary for Signal House thru wall Project Name: ST TO19 2013-018 08/29/2013 Prepared by: CDi Engineers 04:59PM Air System Information Air System Name .. Signal House thru wall Equipment Class UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Number of zones Floor Area Location ... ..... Calculation Months Sizing Data ... 1 Seattle IAP, Washington ,,,Jan to Dec Calculated Supply Fan Sizing Data Actual max CFM 851 CFM Fan motor BHP .. 0.00 BHP Standard CFM _ 838 CFM Fan motor kW 0.00 kW Actual max CFM/ftz 23.65 CFM/ft2 Fan static . 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/person _ ... 0.00 CFM/person CFM/ft2 . 0.00 CFM/ft2 Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Signal House thru wall Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Air System Information Air System Name Signal House thru wall Equipment Class UNDEF Air System Type ....... ...... SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM ._. Space CFM Zone Sizing Data Sum of space airflow rates Individual peak space loads Number of zones .,. Floor Area ....__._ Location Calculation Months Sizing Data . . 1 36.0 ft2 Seattle IAP, Washington Jan to Dec Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft' Signal House Zn 19.9 851 851 Jul 1500 1.5 36.0 23.65 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Signal House Zn Small Signal House 1 19.9 Jul 1500 851 1.5 36.0 23.65 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Signal House thru wall Project Name: ST TO19 2013-018 Prepared by: CD Engineers 08/29/2013 04:59PM DESIGN COOLING DESIGN HEATING NO COOLING DATA NO COOLING OA DB / WB HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTUIhr) Window & Skylight Solar Loads 0 ft2 - - 0 ft2 - - Wall Transmission 156 ft2 - - 156 ft' 590 - Roof Transmission 36 ft2 - - 36 ft2 136 - Window Transmission 0 ft' - - 0 ft2 0 - Skylight Transmission 0 ft' - - 0 ft' 0 - Door Loads 24 ft' - - 24 ft' 735 - Floor Transmission 0 ft' - - 0 ft' 0 - Partitions 0 ft' - - 0 ft' 0 - Ceiling 0 ft2 - - 0 ft' 0 - Overhead Lighting - - - 0 0 - Task Lighting - - - 0 0 - Electric Equipment - - - 0 0 - People - - - 0 0 0 Infiltration - - - - 0 0 Miscellaneous - - - - 0 0 Safety Factor 5% / 0% - - 0% 0 0 » Total Zone Loads - - - - 1462 0 Zone Conditioning - - - - 45 0 Plenum Wall Load 0% - - 0 0 - Plenum Roof Load 0% - - 0 0 - Pienum Lighting Load 0% - - 0 0 Return Fan Load - - - 851 CFM 0 - Ventilation Load - - - 0 CFM 0 0 Supply Fan Load - - - 851 CFM 0 - Space Fan Coil Fans - - - - 0 - Duct Heat Gain / Loss 0% - - 0% 0 - » Total System Loads - - - - 45 0 » Total Conditioning - - - - 0 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Signal House thru wall Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE " Small Signal House " IN ZONE " Signal House Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F OCCUPIED T-STAT 80.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTUIhr) Details (BTU/hr) (BTUIhr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft2 - - Wall Transmission 156 ft' 384 - 156 ft' 590 - Roof Transmission 36 ft' 112 - 36 ft' 136 - Window Transmission 0 ft' 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 24 ft2 25 - 24 ft2 735 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft' 0 - 0 ft2 0 - Overhead Lighting 400 W 1364 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 5004 W 17072 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 5% / 0% 948 0 0% 0 0 » Total Zone Loads - 19905 0 - 1462 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " Small Signal House " IN ZONE " Signal House Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft') (BTU/(hr-ft' °F)) Coeff. (BTU/hr) (BTU/hr) (BTUIhr) W EXPOSURE WALL 45 0.080 - 198 - 170 S EXPOSURE WALL 45 0.080 - 114 - 170 E EXPOSURE WALL 21 0.080 - 29 - 79 DOOR 24 0.652 - 25 - 735 N EXPOSURE WALL 45 0.080 - 44 - 170 H EXPOSURE ROOF 36 0.080 - 112 - 136 Hourly Analysis Program v4.60 Page 4 of 4 Sub -Station Package E-W Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM 1. General Details: Air System Name Equipment Type Air System Type Number of zones 2. System Components: Ventilation Air Data: Airflow Control ___ Ventilation Sizing Method Unocc. Damper Position Damper Leak Rate ... Outdoor Air CO2 Level Central Cooling Data: Supply Air Temperature Coil Bypass Factor Cooling Source._. Schedule Capacity Control .. Central Heating Data: Supply Temperature Heating Source Schedule Capacity Control Supply Fan Data: Fan Type Configuration Fan Performance Overall Efficiency Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Retum Air Via 3. Zone Components: Space Assignments: Sub -Station Package E-W ....Undefined Single Zone CAV 1 Constant Ventilation Airflow Sum of Space OA Airflows Closed ._.__.......... 400 ppm 0.100 Any JFMAMJJASOND Cycled or Staged Capacity - Fan On ._.95.0 °F . Any JFMAMJJASOND Cycled or Staged Capacity - Fan On Forward Curved Draw-thru 0.00 in wg ..54 0 % 0 % Ducted Return Zone 1: Sub Station Zn TPSS e-w x1 Thermostats and Zone Data: Zone Cooling T-stat: Occ. Cooling T-stat: Unocc. Heating T-stat: Occ. Heating T-stat: Unocc. T-stat Throttling Range Diversity Factor Direct Exhaust Airflow Direct Exhaust Fan kW Thermostat Schedule Unoccupied Cooling is Supply Terminals Data: Zone Terminal Type Minimum Airflow Zone Heating Units: Zone Zone Heating Unit Type All 90.0 °F 90.0 °F 70.0 °F 65.0 °F 1.50 °F 100 % 0.0 CFM 0.0 kW Sample Schedule Available All Diffuser 0.00 CFM/person All None Zone Unit Heat Source .Any Hourly Analysis Program v4.60 Page 1 of 2 Sub -Station Package E-W Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Zone Heating Unit Schedule.. 4. Sizing Data (Computer -Generated): System Sizing Data: Hydronic Sizing Specifications: Chilled Water Delta-T . ... Hot Water Delta-T Safety Factors: Cooling Sensible Cooling Latent Heating _ Zone Sizing Data: Zone Airflow Sizing Method Space Airflow Sizing Method 5. Equipment Data No Equipment Data required for this system. JFMAMJJASOND 10.0 °F _ 20.0 °F 0 % 0 % .. Sum of space airflow rates Individual peak space loads Hourly Analysis Program v4.60 Page 2 of 2 Air System Sizing Summary for Sub -Station Package E-W Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Air System Information Air System Name . Sub -Station Package E-W Equipment Class UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM ,,. __.._ Sum of space airflow rates Space CFM Individual peak space loads Number of zones Floor Area ,., Location ._...... Calculation Months ... Sizing Data 1 790.0 ft2 Seattle IAP, Washington Jan to Dec Calculated Central Cooling Coil Sizing Data Total coil load ..._.. ... 9.8 Tons Load occurs at Jul 1500 Total coil load _.. ... 117.3 MBH OA DB / WB ....85.0 / 65.0 °F Sensible coil load 117.3 MBH Entering DB / WB .91.8 / 53.2 F Coil CFM at Jul 1500 3470 CFM Leaving DB / WB 60.0 / 38.1 °F Max block CFM 3470 CFM Coil ADP 56.5 °F Sum of peak zone CFM 3470 CFM Bypass Factor 0.100 Sensible heat ratio . 1.000 Resulting RH „_... .......... 0 % ft2/Ton ........ ..... 80.8 Design supply temp. .,. ... 58.0 °F BTU/(hr-ft2) 148.5 Zone T-stat Check . 0 of 1 OK Water flow @ 10.0 °F rise . .23.47 gpm Max zone temperature deviation 0.3 °F Central Heating Coil Sizing Data Max coil load 12.0 MBH Load occurs at .... Des Htg Coil CFM at Des Htg 3470 CFM BTU/(hr-ft2) 15.1 Max coil CFM . 3470 CFM Ent. DB / Lvg DB 69.8 / 73.1 °F Water flow @ 20.0 °F drop 1.20 gpm Supply Fan Sizing Data Actual max CFM Standard CFM Actual max CFM/ft' 3470 CFM 3414 CFM 4.39 CFM/ft2 Fan motor BHP Fan motor kW Fan static. 0.00 BHP 0.00 kW 0.00 in wg Outdoor Ventilation Air Data Design airflow CFM 0 CFM CFM/person 0.00 CFM/person CFM/ft2 0.00 CFM/ft2 Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Sub -Station Package E-W Project Name: ST TO19 2013-018 08/29/2013 Prepared by: CDI Engineers 04:59PM Air System Information Air System Name Sub -Station Package E-W Equipment Class ... _..,. UNDEF Air System Type .. SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM .... . Individual peak space loads Zone Sizing Data Number of zones Floor Area ..... Location Seattle IAP, Washington Calculation Months ... .,.. .Jan to Dec Sizing Data Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft2 Sub Station Zn 118.0 3470 3470 Jul 1500 12.0 790.0 4.39 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Sub Station Zn TPSS e-w 1 118.0 Jul 1500 3470 12.0 790.0 4.39 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Sub -Station Package E-W Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1600 COOLING OA DB / WB 85.0 °F / 65.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft' - - Wall Transmission 1096 ft2 2535 - 1096 ft' 4844 - Roof Transmission 790 ft' 2097 - 790 ft' 3492 - Window Transmission 0 ft' 0 - 0 ft2 0 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 120 ft2 -655 - 120 ft2 3677 - Floor Transmission 0 ft' 0 - 0 ft' 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft' 0 - 0 ft2 0 - Overhead Lighting 1185 W 4042 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 32230 W 109959 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 117978 0 - 12013 0 Zone Conditioning - 117285 0 - 11954 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 3470 CFM 0 - 3470 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 3470 CFM 0 - 3470 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 117285 0 - 11954 0 Central Cooling Coil - 117285 0 - 0 0 Central Heating Coil - 0 - - 11954 - » Total Conditioning - 117285 0 - 11954 0 Key: Positive values are clg Toads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Sub -Station Package E-W Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE "TPSS a-w " IN ZONE " Sub Station Zn " DESIGN COOUNG DESIGN HEATING COOLING DATA AT Jul 1500 COOLING OA DB / WB 85.0 °F / 65.0 °F OCCUPIED T-STAT 90.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wali Transmission 1096 ft2 2535 - 1096 ft2 4844 - Roof Transmission 790 ft2 2097 - 790 ft2 3492 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 120 ft2 -655 - 120 ft2 3677 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 IV 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1185 W 4042 - 0 0 - Task Lighting 0 W 0 - 0 0 Electric Equipment 32230 W 109959 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 117978 0 - 12013 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " TPSS a-w " IN ZONE " Sub Station Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft2) (BTU/(hr-ft2-°F)) Coeff. (BTU/hr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 470 0.094 - 2001 - 2077 S EXPOSURE WALL 114 0.094 - 224 - 504 DOOR 24 0.652 - -131 - 735 E EXPOSURE WALL 470 0.094 - 303 - 2077 N EXPOSURE WALL 42 0.094 - 8 - 186 DOOR 96 0.652 - -524 - 2942 H EXPOSURE ROOF 790 0.094 - 2097 - 3492 Hourly Analysis Program v4.60 Page 4 of 4 Sub -Station Package N-S Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM 1. General Details: Air System Name Equipment Type Air System Type Number of zones 2. System Components: Ventilation Air Data: Airflow Control Ventilation Sizing Method Unocc. Damper Position Damper Leak Rate ..... Outdoor Air CO2 Level Central Cooling Data: Supply Air Temperature Coil Bypass Factor Cooling Source .., Schedule Capacity Control Central Heating Data: Supply Temperature Heating Source Schedule . _... Capacity Control Supply Fan Data: Fan Type ........ . Configuration Fan Performance Overall Efficiency Duct System Data: Supply Duct Data: Duct Heat Gain Duct Leakage Return Duct or Plenum Data: Retum Air Via 3. Zone Components: Space Assignments: ._... ....._SubStation Package N-S .. ,Undefined Single Zone CAV 1 .. Constant Ventilation Airflow Sum of Space OA Airflows Closed ......., 400 ppm 58.0 °F . 0.100 Any JFMAMJJASOND Cycled or Staged Capacity - Fan On 95.0 °F .. Any JFMAMJJASOND Cycled or Staged Capacity - Fan On Forward Curved Draw-thru 0.00 in wg 54 % 0 % 0 % Ducted Return Zone 1: Sub Station Zn TPSS n-s x1 Thermostats and Zone Data: Zone .... Cooling T-stat: Occ. Cooling T-stat: Unocc. Heating T-stat: Occ. Heating T-stat: Unocc. T-stat Throttling Range Diversity Factor Direct Exhaust Airflow Direct Exhaust Fan kW Thermostat Schedule Unoccupied Cooling is Supply Terminals Data: Zone Terminal Type Minimum Airflow Zone Heating Units: Zone Zone Heating Unit Type All 90.0 90.0 70.0 65.0 1.50 100 0.0 0.0 Sample Schedule Available °F °F °F °F CFM kW All Diffuser 0.00 CFM/person All None Zone Unit Heat Source Any Hourly Analysis Program v4.60 Page 1 of 2 Sub -Station Package N-S Input Data Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 04:59PM Zone Heating Unit Schedule 4. Sizing Data (Computer -Generated): System Sizing Data: Cooling Supply Temperature Supply Fan Airflow Ventilation Airflow Heating Supply Temperature Hydronic Sizing Specifications: Chilled Water Delta-T Hot Water Delta-T ... Safety Factors: Cooling Sensible . . Cooling Latent Heating Zone Sizing Data: Zone Airflow Sizing Method .. Space Airflow Sizing Method JFMAMJJASOND 58.0 °F 3470.7 CFM . 0.0 CFM 95.0 °F _ 10.0 °F 20.0 °F 0 0 % 0 % Sum of space airflow rates Individual peak space Toads Zone Supply Airflow (CFM) Zone Htg Unit (MBH) Reheat Coil (MBH) - (CFM) 1 3470.7 - - 5. Equipment Data No Equipment Data required for this system. Hourly Analysis Program v4.60 Page 2 of 2 Air System Sizing Summary for Sub -Station Package N-S Project Name: ST TO19 2013-018 08/29/2013 Prepared by: CDi Engineers 05:OOPM Air System Information Air System Name Sub -Station Package N-S Equipment Class UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Space CFM Individual peak space loads Number of zones .,1 Floor Area 790.0 ft2 Location Seattle IAP, Washington Calculation Months ... Sizing Data Jan to Dec Calculated Central Cooling Coil Sizing Data Total coil load.. .,.... 9.8 Tons Load occurs at _ ... Jul 1300 Total coil load .... 117.1 MBH OA DB / WB .83.0 / 64.3 °F Sensible coil load.117.1 MBH Entering DB / WB . 91.8 / 53.1 °F Coil CFM at Jul 1300 3471 CFM Leaving DB / WB ....... 60.0 / 38.2 °F Max block CFM . ... . .. .. 3471 CFM Coil ADP ..... 56.5 °F Sum of peak zone CFM 3471 CFM Bypass Factor ... 0.100 Sensible heat ratio 1.000 Resulting RH . .. % ft2/Ton 80.9 Design supply temp. 58.0 °F BTU/(hr-ft2) _ ... . 148.3 Zone T-stat Check . .0 of 1 OK Water flow @ 10.0 *F rise 23.44 gpm Max zone temperature deviation 0.3 F Central Heating Coil Sizing Data Max coil load 10.9 MBH Load occurs at Des Htg Coil CFM at Des Htg . _. 3471 CFM BTU/(hr-ft2) ..13.8 Max coil CFM 3471 CFM Ent. DB / Lvg DB 69.7 / 72.6 °F Water flow @ 20.0 °F drop 1.09 gpm Supply Fan Sizing Data Actual max CFM. Standard CFM . Actual max CFM/ft2 Outdoor Ventilation Air Data Design airflow CFM CFM/ft2 . 3471 CFM 3415 CFM 4.39 CFM/ft2 0 CFM 0.00 CFM/ft2 Fan motor BHP Fan motor kW Fan static 0.00 BHP 0.00 kW .. 0.00 in wg CFM/person .0.00 CFM/person Hourly Analysis Program v4.60 Page 1 of 4 Zone Sizing Summary for Sub -Station Package N-S Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 05:OOPM Air System Information Air System Name ...... Sub -Station Package N-S Equipment Class ... UNDEF Air System Type SZCAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM ... Sum of space airflow rates Space CFM Individual peak space loads Zone Sizing Data Number of zones _ 1 Floor Area 790.0 ft2 Location Seattle IAP, Washington Calculation Months ...... ..... ....... ............ ....Jan to Dec Sizing Data Calculated Zone Name Maximum Cooling Sensible (MBH) Design Air Flow (CFM) Minimum Air Flow (CFM) Time of Peak Load Maximum Heating Load (MBH) Zone Floor Area (ft2) Zone CFM/ft2 Sub Station Zn 118.0 3471 3471 Jul 1300 11.2 790.0 4.39 Zone Terminal Sizing Data No Zone Terminal Sizing Data required for this system. Space Loads and Airflows Zone Name! Space Name Mult Cooling Sensible (MBH) Time of Load Air Flow (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Sub Station Zn TPSS n-s 1 118.0 Jul 1300 3471 11.2 790.0 4.39 Hourly Analysis Program v4.60 Page 2 of 4 Air System Design Load Summary for Sub -Station Package N-S Project Name: ST TO19 2013-018 Prepared by: CDi Engineers 08/29/2013 05:00PM DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1300 COOLING OA DB / WB 83.0 °F / 64.3 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTUIhr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 1240 ft2 1905 - 1240 ft2 5481 - Roof Transmission 790 ft2 2579 790 ft2 3492 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 72 ft2 -468 - 72 ft2 2206 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 1185 W 4042 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 32230 W 109958 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 118015 0 - 11179 0 Zone Conditioning - 117149 0 - 10920 0 Plenum Wall Load 0% 0 - 0 0 - Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Return Fan Load 3471 CFM 0 - 3471 CFM 0 - Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 3471 CFM 0 - 3471 CFM 0 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 0% 0 - 0% 0 - » Total System Loads - 117149 0 - 10920 0 Central Cooling Coil - 117149 0 - 0 0 Central Heating Coil - 0 - - 10920 - » Total Conditioning - 117149 0 - 10920 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads Hourly Analysis Program v4.60 Page 3 of 4 Space Design Load Summary for Sub -Station Package N-S Project Name: ST 7019 2013-018 Prepared by: CDi Engineers 08/29/2013 05:00PM TABLE 1.1.A. COMPONENT LOADS FOR SPACE " TPSS n-s " IN ZONE " Sub Station Zn " DESIGN COOLING DESIGN HEATING COOLING DATA AT Jul 1300 COOLING OA DB / WB 83.0 °F / 64.3 °F OCCUPIED T-STAT 90.0 °F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0 °F / 19.2 °F OCCUPIED T-STAT 70.0 °F Sensible Latent Sensible Latent SPACE LOADS Details (BTU/hr) (BTU/hr) Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft' - - Wall Transmission 1240 ft' 1905 - 1240 ft' 5481 - Roof Transmission 790 ft' 2579 - 790 ft2 3492 - Window Transmission 0 ft' 0 - 0 ft' 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 72 ft' -468 - 72 ft' 2206 - Floor Transmission 0 ft' 0 - 0 ft' 0 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 1185W 4042 - 0 0 - Task Lighting 0 W 0 - 0 0 - Electric Equipment 32230 W 109958 - 0 0 - People 0 0 0 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 0% / 0% 0 0 0% 0 0 » Total Zone Loads - 118015 0 - 11179 0 TABLE 1.1.B. ENVELOPE LOADS FOR SPACE " TPSS n-s " IN ZONE " Sub Station Zn " COOLING COOLING HEATING Area U-Value Shade TRANS SOLAR TRANS (ft') (BTU/(hr-ft'-°F)) Coeff. (BTUIhr) (BTU/hr) (BTU/hr) W EXPOSURE WALL 114 0.094 - 218 - 504 DOOR 24 0.652 - -156 - 735 S EXPOSURE WALL 518 0.094 - 1551 - 2290 E EXPOSURE WALL 90 0.094 - 58 - 398 DOOR 48 0.652 - -312 - 1471 N EXPOSURE WALL 516 0.094 - 78 - 2290 H EXPOSURE ROOF 790 0.094 - 2579 - 3492 Hourly Analysis Program v4.60 Page 4 of 4 POST BASE ASSEMBLY FINISHED GRADE 1/8 CONCRETE FOOTING - COMMERCIAL CONCRETE PIPE DRAIN - 3/4" I.D. 7" LONG GRANULAR, FREE DRAINING MATERIAL SECTION OA SEAL WELD DIRECTION OF PEDESTRIAN/ BICYCLE TRAFFIC 1' - 2 12101AM. ROUND FOOTING /8 /8 1/8 1/8" • 1 7/8" SQUARE PLATE 1/8" PLATE 4 3/4" 01AM. 1/0" PLATE - 3 13/18" 0IAM. 81/ " COVER PLATE TOP PLATE POST SLEEVE BASE PLATE POST SLEEVE CAP DIRECTION OF PEDESTRIAN/ BICYCLE TRAFFIC J SQUARE FOOTING PLAN VIEW 0 PAINT ASSEMBLY VATH A "HIGHLY VISIBLE" COLOR. (SAFETY YELLOW IS ACCEPTABLE) 1/4" CHAIN - GRADE 3, 6" LONG COVER PLATE TOP PLATE O. BASE ASSEMBLY STEEL PIPE - ASTM A 53, NPS 4 (4" NOM.). SCHEDULE 40 - WELD TO TOP PLATE 1/8" PLATE 12" CHAMFER (TR.) 3/4" DIAM. DRAIN HOLE BASE PLATE CAP 1/8" • 1 7/8" SQUARE PLATE ALL4 SIDES 1 1/4" • T, FULL SURFACE, HEAW DUTY, WEL0.0N NINGE 1/8" • 4 12" DIAM, STEEL PLATE CAP AND HINGE STEEL CAP PLATE 1/8 12" REFLECTIVE TAPE (TYP.) STEEL PIPE - ASTM A 53, NPS 3 (3" NOM.1, SCHEDULE 80 12" REFLECTIVE TAPE (TYP.) /a 1/4" • 1 12" • 2" STEEL PLATE WTTH ROUNDED CORNERS AND 3/4" CENTERED HOLE POST NOTE This bollard does not have an effective breakaway design feature and cannot be Installed within the Design Clear Zone. EXPIRES JUNE 19, 2010 BOLLARD TYPE 1 STANDARD PLAN H-60.10-0' SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Paseo Bakotich ❑I 07-03-08 STATE WSW/ M. wd. a„g1.3,m. 0.444.•I.1T44(44/ 4444 DRAWN BY: BILL BERENS FINISHED GRADE CONCRETE FOOTING - COMMERCIAL CONCRETE 6' • 1/4" OIAM. STEEL BAR POST SECTION ROUND FOOTING PLAN VIEW STEEL CAP PLATE 12. REFLECTIVE TAPE (TYP.) STEEL PIPE - ASTM A 53, NPS 3 (T NOM.), SCHEDULE 80 Ur REFLECTIVE TAPE (TYP.) FRONT VIEW SIDE VIEW 0 PAINT ASSEMBLY PATH A'HIGHLY VISIBLE" COLOR. (SAFETY YELLOW 15 ACCEPTABLE) POST 1. - 21/2- SQUARE FOOTING j NOTE This bollard does not have an effective breakaway design feature and cannot be installed within the Design Clear Zone. 511& GRILLED HOLE EXPIRES JUNE 19, 2010 BOLLARD TYPE 2 STANDARD PLAN H-60.20.01 SHEET 1 OF 1 SHEET APPROVED FOR PUBLICATION Paseo Bakotich 111 07-03-08 STATE ... w.1110 . Daft P: r.rTAn.P.rl.u.. City of Tukwila Department of Community Development 10/3/2016 NICOLE SIEBEL 401 S JACKSON ST SEATTLE, WA 98104 RE: Permit No. M15-0081 SOUND TRANSIT 11005 E MARGINAL WAY SOUTH Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 11/25/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 11/25/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0081 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director May 17, 2016 Nicole Siebel Sound Transit 401 S Jackson St Seattle, WA 98104 RE: Request for Extension #1 Permit Number M15-0081 Dear Ms. Siebel, This letter is in response to your written request for an extension to Permit M15-0081. The Building Official, Jerry Hight, has reviewed your letter and considered your request to extend the above referenced permit. It has been determined that the City of Tukwila Building Division will be granting an extension to the permit through November 25, 2016. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File: Permit No. M15-0081 W.\Permit Center"Extension Letters\Permits\2015W115-0081 Permit Extension #1.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 MEMO t'SOUNDTRANSIT May 12, 2016 TO: Bill Rambo FROM: Nicole Siebel SUBJECT: Request for Extension Electrical Permit No. M 15-0081 Dear Mr. Rambo Sound Transit respectfully requests an extension of the existing Mechanical Permit # M 15-0081 for installation of air conditioning in our Traction Powered Substation. This work has been put on hold while we await award of this project to a contractor. This extension will reduce project start up times to allow the contractor to begin work as soon as they are granted Notice to Proceed. Should you have any questions, please do not hesitate to contact me. My office number is 206 370-5693 and my email is nicole.siebel@soundtransit.org. Best Regards, Nicole Siebel Project Coordinator - Permits Request for Extension # Current Expiration Date: (Q Extension Request: Approved for D days Denied (provide explanation) Signature/Initials RECEIU`EL CITY OF TUKWI'Lp MAY 13 2tUIb PERMIT CENTER City of Tukwila Department of Community Development 5/3/2016 NICOLE SIEBEL 401 S JACKSON ST SEATTLE, WA 98104 RE: Permit No. M15-0081 SOUND TRANSIT 11005 E MARGINAL WAY SOUTH Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/25/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/25/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0081 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 City of Tukwila Department of Community Development November 4, 2015 NICOLE SIEBEL 401 S JACKSON ST SEATTLE, WA 98104 RE: Application No. M15-0081 SOUND TRANSIT 11005 E MARGINAL WAY S Dear NICOLE SIEBEL: Jim Haggerton, Mayor Jack Pace, Director Permit application M15-0081 for the work proposed at SOUND TRANSIT (11005 E MARGINAL WAY S) has not been issued by the City of Tukwila Permit Center. Per the International Building, Residential, and Mechanical Codes as well as the Uniform Plumbing Code and/or the National Electric Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire 12/29/2015. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is completed for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that your permit is not issued, we do not receive your written request for extension, or your request is denied your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0081 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0081 PROJECT NAME: SOUND TRANSIT DATE: 06/29/15 SITE ADDRESS: I I 00,5,., E MARGINAL WAY SOUTH X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works MA Fire Prevention Structural 14/0 Planning Division Permit Coordinator El PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 06/30/15 Structural Review Required DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required Approved with Conditions Denied (corrections entered in Reviews) (ie: Zoning Issues) DUE DATE: 07/28/15 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg D Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 CITY OF TUKWILA Department of Community Development 630o Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-367o FAX (206) 431-3665 Permit Center/Building Division 206 431-367o Public Works Department 206 433-0179 Planning Division 206 431-367o AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION P//5-00fr1 PERMIT NO: yyJ00 ?(-3 STATE OF WASHINGTON) ) ss. COUNTY OF KING ) �c(k) Sthe2 [please print name] , states as follows: 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requireme t of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number l , and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in any decision to engage an unregistered contractor to perform construction LAURIE A. WERLE NOTARY PUBLIC STATE OF WASHINGTON COMMISSION EXPIRES MAY 29, 2018 tliaej Owner/Owner's Agent* Signed and sworn to before me this_ day of Pre7)1 J r , 20 PUBLIC in and for the State of Washington Residing at Name as commissioned: , County My commission expires: 0 'I ? // 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.7o RCW who shall warranty service and repairs under chapter 46.7o RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; io. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; l t. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer; 18. An entity who holds a valid electrical contractor's license under chapter 19.28 RCW that employs a certified journeyman electrician, a' certified residential specialty. electrician, or an electrical. trainee meeting the requirements of chapter 19.28 RCW to perform plumbing work that is incidentally, directly, and immediately appropriate to the like -in -kind replacement of a household appliance or other small household utilization equipment that requires limited electric power and limited waste and/or water connections.An electrical trainee mustbe supervised by a certified electrician while performing plumbing work. *Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. a co 5(7/2015 2:56:29 PM 0 i ST NON -CRITICAL INSTRUMENT HOUSE HVAC INS O co U:\114351-114700\1 CENTRAL PUGET SOUND REGIONAL TRANSIT AUTHORITY P.OJECT LOCATIO\ L_OCATIO\ VAP NOT TO SCALE �y �����■ �■ nil ��; ..�111111..:■11111n. wit ■w�rrrrrrr■ •r ►�tiir'iiei ' S111 s9 `orml..r- ■ 111111111W ■ 1 111 1111I1 4MIMI! ■Iltll'H1 1111 ■1 l ld!sp. r 1■11■11161.1 I1 no IY 111iitu 11f 11111 111. !■ 1�11a: 1■11 rivrip ■■NII■ / ■■i=■ �■. IIIIIIII '■I■■■1 I ■■®■iUI!IIIN1 L rlI111. rah- DIPio pm, II ! ri !r, j I • i. ��uill i■. ;CA a■■wnmuaa a% ■L■■ ■■■■■►■■I ■'�111 artoulaii k :lam..111►�1: !' - uaruul .. 9fitgral 11lt__I 11o,. \ Ir■ii11I1MIWIL I/11111I ii� Burien Lake H uIIh 911 \ 11! s,uH s„Mn VICI\TY V A MLEV SAME W. VAWRHOWMW PROJECT\ LOCATIONS SCALE: 1" = 4000' ' slzmisT 1.„ -C' ITICAL INSTR VAC INSTALL,k,,,,TI CONTRACT CN 0056-15 0036 100% IFB DRAWINGS MAY 8, 2015 E. EPARATE Fes: EMIT OUIREU 7 CR: 0 Mechanical .12T Elcctricat plumbtfig "Gas PipinS City of Tukwila ,BLIIIS),740 DIVISION PREPARED BY: KPFF CONSULTING ENGINEERS SUBMITTED BY: DATE: REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. MOTE: Revisions will require a new plan submittal and may include additional plan review fps. itRon of tfto of any of Jo Mlq-p091 to am and ctni aulhoJza code or BUILDING �of Tukwila DIVISION SARA L. ROBERTS, S..E PRINCIPAL DESIGNER KPFF CONSULTING ENGINEERS REVIEWED BY: BRYON AGAN, P.E. CIVIL ENGINEERING SUPERVISOR DATE: �REVi�WED FOR I CODE COMPLIANCE APPROVED �)JUL 01 2015 '," 1` 2- City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 29 2015 PERMIT CENTER DRAWING No. SM0036-GZO1 LOCATION ID: SHEET No. 1 REV: 0 INDEX OF DRAWINGS PROJECT INFORMATION SHT NO. DWG NO. REV TITLE GENERAL 1 2 3 SM0036-GZO1 SM0036-GZO2 SM0036-GZO3 0 0 0 COVER SHEET DRAWING INDEX, PROJECT INFORMATION, PROJECT TEAM GENERAL NOTES, ABBREVIATIONS AND SYMBOLS, GENERAL DETAILS CIVIL 4 5 6 7 8 9 10 11 12 13 14 15 16 17 SM0036-CP01 SM0036-CP02 SM0036-CP03 SM0036-CP04 SM0036-CP05 SM0036-CP06 SM0036-CP07 SM0036-CP08 SM0036-CP09 SM0036-CP10 SM0036-TTO1 SM0036-TTO2 SM0036-TTO3 SM0036-TTO3 ARCHITECTURAL 0 0 0 0 0 0 0 0 0 0 0 0 0 0 HVAC EQUIPMENT LAYOUT - ROYAL BROUGHAM HVAC EQUIPMENT LAYOUT - STADIUM HVAC EQUIPMENT LAYOUT - SOUTH HOLGATE HVAC EQUIPMENT LAYOUT - SOUTH LANDER HVAC EQUIPMENT LAYOUT - YARD NORTH HVAC EQUIPMENT LAYOUT - YARD SOUTH HVAC EQUIPMENT LAYOUT - BOEING HVAC EQUIPMENT LAYOUT - SOUTH 133RD HVAC EQUIPMENT LAYOUT - TUKWILA HVAC EQUIPMENT LAYOUT - AIRPORT TRAFFIC CONTROL PLAN ROYAL BROUGHAM TRAFFIC CONTROL PLAN STADIUM TRAFFIC CONTROL PLAN SOUTH HOLGATE TRAFFIC CONTROL PLAN SOUTH LANDER 18 SM0036-ADO1 0 ARCHITECTURAL DETAILS MECHANICAL SM-0036\SM0036GZ02.DWG z 0 U co O cn a U ir U O av u)o J w a. c (V � e- Lo 19 20 21 22 23 24 25 26 27 28 29 30 31 SM0036-MZ01 SM0036-MZ02 SM0036-MZ03 SM0036-MH01 SM0036-MH02 SM0036-MH03 SM0036-MH04 SM0036-MH05 SM0036-MH06 SM0036-MH07 SM0036-MH08 SM0036-MH09 SM0036-MH 10 ELECTRICAL 0 0 0 0 0 0 0 0 0 0 0 0 0 MECHANICAL LEGEND AND ABBREVIATIONS GENERAL NOTES AND ENERGY CODE EQUIPMENT SCHEDULES, CONTROL SEQUENCE AND DIAGRAM SIGNAL HOUSE EQUIPMENT PLAN - ROYAL BROUGHAM SIGNAL HOUSE EQUIPMENT PLAN - STADIUM SIGNAL HOUSE EQUIPMENT PLAN - SOUTH HOLGATE SIGNAL HOUSE EQUIPMENT PLAN - SOUTH LANDER SIGNAL HOUSE EQUIPMENT PLAN - YARD NORTH SIGNAL HOUSE EQUIPMENT PLAN - YARD SOUTH SIGNAL HOUSE EQUIPMENT PLAN - BOEING SIGNAL HOUSE EQUIPMENT PLAN - SOUTH 133RD SIGNAL HOUSE EQUIPMENT PLAN - TUKWILA SIGNAL HOUSE EQUIPMENT PLAN - AIRPORT 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 SM0036-EZ01 SM0036-EP01 SM0036-EPO2 SM0036-EPO3 SM0036-EPO4 SM0036-EPO5 SM0036-EPO6 SM0036-EPO7 SM0036-EPO8 SM0036-EPO9 SM0036-EP10 0 0 0 0 0 0 0 0 0 0 0 LEGEND AND ABBREVIATIONS ELECTRICAL PLAN - ROYAL BROUGHAM ELECTRICAL PLAN - STADIUM ELECTRICAL PLAN - SOUTH HOLGATE. ELECTRICAL PLAN - SOUTH LANDER ELECTRICAL PLAN - YARD NORTH ELECTRICAL PLAN - YARD SOUTH ELECTRICAL PLAN - BOEING ELECTRICAL PLAN - SOUTH 133RD ELECTRICAL PLAN - TUKWILA ELECTRICAL PLAN - AIRPORT SM0036-ED01 SM0036-ED02 0 0 ELECTRICAL PANEL SCHEDULE - ELECTRICAL PANEL SCHEDULE - ROYAL BROUGHAM STADIUM SM0036-ED03 SM0036-ED04 SM0036-ED05 0 0 0 ELECTRICAL PANEL SCHEDULE - SOUTH HOLGATE ELECTRICAL PANEL SCHEDULE - SOUTH LANDER ELECTRICAL PANEL SCHEDULE - YARD NORTH SM0036-ED06 SM0036-ED07 SM0036-ED08 SM0036-ED09 SM0036-ED10 0 0 0 0 0 ELECTRICAL PANEL SCHEDULE - YARD SOUTH ELECTRICAL PANEL SCHEDULE - BOEING ELECTRICAL PANEL SCHEDULE - SOUTH 133RD ELECTRICAL PANEL SCHEDULE - TUKWILA ELECTRICAL PANEL SCHEDULE - AIRPORT DATE DSN CHK _ APP REVISION DESIGNED BY: D. TIMPSON DRAWN BY: W. MAIPID CHECKED BY: T. BRUCE APPROVED BY: S.ROBERTS DESCRIPTION OF WORK: THIS PROJECT INCLUDES INSTALLATION OF AIR CONDITIONING EQUIPMENT AT SOUND TRANSIT SIGNAL INSTRUMENT HOUSE FACILITIES ASSOCIATED WITH CENTRAL AND SOUTH CORRIDOR LINK LIGHT RAIL. ASSOCIATED WORK INCLUDES BUT IS NOT LIMITED TO SPLIT SYSTEM AIR CONDITIONING UNITS, CONCRETE EQUIPMENT PADS, WIRING, CONDUIT, REFRIGERANT PIPING, ELECTRICAL AND MECHANICAL ACCESSORIES, AND COMMISSIONING. PROJECT LOCATIONS: (ADDRESSES ARE APPROXIMATE) ROYAL BROUGHAM: ROYAL BROUGHAM & SODO BUSWAY SEATTLE WA 98134 STADIUM: ROYAL BROUGHAM LIGHT RAIL STATION SEATTLE WA 98134 SOUTH HOLGATE: S. HOLGATE & SODO BUSWAY SEATTLE WA 98134 SOUTH LANDER: S. LANDER & SODO BUSWAY SEATTLE WA 98134 YARD NORTH & SOUTH: ST OPERATIONS & MAINTENANCE FACILITY 3704 AIRPORT WAYS SEATTLE WA 98134 BOEING: 11037 E MARGINAL WAY S TUKWILA WA 98168 SOUTH 133RD STREET: 4562 S 133 RD TUKWILA WA 98168 TUKWILA: TUKWILA INT BOULEVARD STATION 15426 SOUTH CENTER BOULEVARD TUKWILA WA 98188 C37 AIRPORT: 17151 PACIFIC HIGHWAY S. SEATTLE WA 98158 PROJECT TEAM CLIENT: SOUND TRANSIT UNION STATION 401 JACKSON STREET SEATTLE, WA 98104 CONTACT: BARRY ALAVI 206.398.5433 STRUCTURAL ENGINEER: KPFF CONSULTING ENGINEEERS 1601 5TH AVE, SUITE 1600 SEATTLE, WA 98101 CONTACT: SARA ROBERTS 206.622.5822 206.622.8130 (FAX) PRIME CONSULTANT: KPFF CONSULTING ENGINEERS 1601 5TH AVE, SUITE 1600 SEATTLE, WA 98101 CONTACT: SARA ROBERTS 206.622.5822 206.622.8130 (FAX) ARCHITECT: TISCARENO ASSOCIATES 500 UNION ST SUITE 926 SEATTLE, WA 98101 CONTACT: CHARLES WRIGHT 206.325.3356 206.701.9769 (FAX) MECHANICAL ENGINEER: COI ENGINEERS 19203 36TH AVE W. BLDG 4 SUITE 200....... LYNNWOOD WA 98.36 CONTACT: JON DELLA 425.672.1071 425.778.8769 (FAX) ELECTRICAL ENGINEER: ELCON ASSOCIATES 16300 CHRISTENSEN ROAD SUITE 330 SEATTLE,WA 98188 CONTACT: HAROLD SMYTH 206.243.5022 206.243.5205 (FAX) REViEWED FOR CODE COMPLIANCE APPROVED JUL 01 2015 City of Tukwila BUILDING DIVISION Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED BY: D. TIMPSON DATE: 5/8/15 REVIEWED BY: B. ALAVI a co w z J FULL SCALE SOUNDTRANSIT DATE: 5/8/15 SCALE: NO SCALE FILENAME: SM0036GZ02.dwg CONTRACT No.: CN 0056-15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES SM0036-GZO2 NON -CRITICAL HOUSES RL-"-COVE D CITY OF TUKWILA JUN 29 2015 PERMIT CENTER DRAWING No.: DRAWING INDEX PROJECT INFORMATION PROJECT TEAM LOCATION ID: SHEET No.: REV: 02 0 0 0 N 0 toI 0 0 M O O cn z O g a co z co 0 O z w co z cai i= o: U U u) • 0 ▪ co wCO a o 0 N 0 GENERAL .. NOTES DESCRIPTION LINETYPES ABBREVIATIONS 1. LOCATIONS SHOWN FOR EXISTING UTILITIES ARE APPROXIMATE. FIELD -LOCATE EXISTING UTILITIES TO DETERMINE EXTENT OF PROTECTION NEEDED AND/OR CHANGES THAT MAY BE REQUIRED. USE CARE WHEN @ AT MAX MAXIMUM ABD ABANDON, ABANDONED MECH MECHANICAL EXCAVATING NEAR EXISTING UTILITIES. EXISTING RIGHT-OF-WAY LINE ABV ABOVE MH MAINTENANCE HOLE ADDL ADDITIONAL MIC(S) MONUMENT IN CASE(S) 2. UTILITY LOCATES: CALL MINIMUM 2 AND MAXIMUM 10 BUSINESS DAYS BEFORE YOU DIG. 1 (800) 424-5555. EXISTING PROPERTY/LOT LINE AHD AHEAD MIN MINIMUM ALT ALTERNATE MISC MISCELLANEOUS 3. MAINTAIN SEWER MAINTENANCE HOLES, WATER VALVES AND METERS, FIRE HYDRANTS, AND UTILITY VAULTS BLOCKAGE BY CONTRACTOR EQUIPMENT, MATERIALS, OR DEBRIS. SECTION LINE & AND MON(S) MONUMENT(S) APPROX APPROXIMATELY ACCESSIBLE AND CLEAR OF 4. ALL DRAWINGS ARE SCHEMATIC AND ARE NOT TO SCALE. GC SHALL FIELD VERIFY ALL DIMENSIONS AND CENTERLINE LINK FENCE ARCH ARCHITECT, ARCHITECTURE N NORTH ASPH ASPHALT NB NORTH BOUND AVE AVENUE NE NORTHEAST AS -BUILT CONDITIONS. CHAIN EQUIPMENT CLEARANCES >< x x x >< x >< x >< >< AVG AVERAGE NIC NOT IN CONTRACT No, # NUMBER 5. DASHED LINES AT NEW HVAC UNITS INDICATE MANUFACTURER'S RECOMMENDED CLEARANCES FOR AIR INTAKE/EXHAUST, INSTALLATION, MAINTENANCE/SERVICE ACCESS, AND ECONOMIZER AND HOOD PER BK BACK NTP NOTICE TO PROCEED SPECIFICATIONS. 6. PROPOSED UNIT LOCATIONS, UTILITY CONDUIT ROUTING AND ALL ASSOCIATED CLEARANCES SHALL BE REVIEWED AND VERIFIED IN THE FIELD BY GC AT EACH LOCATION IN COORDINATION WITH ST RE. 7. DUCTWORK, CONDUIT & PIPING SUPPORT IS THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL MEET APPLICABLE CODES AND STANDARDS FOR SUPPORT AND RESTRAINT OF ALL NEW AND RELOCATED CONTRACTOR MATCH WORKING LINE LIMITS 401111=1=000101.1 BEG BEGIN NTS NOT TO SCALE B/H BULKHEAD NW NORTHWEST BLD,BLDG BUILDING BLVD BOULEVARD OFCI OWNER FURNISHED CONTRACTOR BLW BELOW INSTALLED BMS BUILDING MANAGEMENT SYSTEM BOT BOTTOM PERP PERPENDICULAR DUCTWORK, CONDUIT AND PIPING. 8. ALL SERVICE INTERRUPTIONS AND DISCONNECTIONS SHALL BE SCHEDULED IN ADVANCE WITH ST RE. WHERE DESCRIPTION HATCH PATTERNS BTWN BETWEEN PC PRECAST PCC POINT OF COMPOUND CURVATURE CB CATCH BASIN PROP PROPOSED REQUIRED, DISCONNECTION AND RELOCATION/RECONNECTION OF NET WORK CONTROLLER BOX TO BE COORDINATED WITH ST RE. DISCONNECTION AND RELOCATION/RECONNECTION OF ANY SIGNAL EQUIPMENT SHALL BE COORDINATED BY THE CONTRACTOR WITH KCM OPERATIONS FOR REVIEW, APPROVAL AND ALL HATCH PATTERN ORIENTATION IS BASED OFF NORTH CCTV CLOSED CIRCUIT TELEVISION . PROPERTY LINE CDF CONTROLLED DENSITY FILL PVMT PAVEMENT CIP CAST -IN -PLACE ADVANCE SCHEDULING. CONCRETE • ` ' • c. CENTERLINE RCD RECORD CTR CENTER REQD REQUIRED 9. MOUNTING DETAILS FOR NEW EQUIPMENT TO WALLS OR EQUIPMENT PADS ARE CONTRACTORS CONC CONCRETE REV REVERSIBLE RESPONSIBILITY OR PER MANUFACTURER'S INSTRUCTIONS UNO. AGGREGATE BASE COURSE o 0 0 r '� CONST CONSTRUCTION RIM RIM ELEVATION COORD COORDINATE RO ROUGH OPENING CONT CONTINUED ROW,R/W RIGHT-OF-WAY 10. NEW CONDUIT AND WIRE ROUTING, AND RELOCATION OF EXISTING CONDUIT, WIRING AND EQUIPMENT TO ACCOMMODATE NEW INSTALLATION WILL BE BY CONTRACTOR WITH FIELD VERIFICATION OF EXISTING SPACE EXISTING STRUCTURE TO BE REMOVED ////////// COS CITY OF SEATTLE RT RIGHT LIMITATIONS. CP CROSS PASSAGE S SOUTH DEPT DEPARTMENT SB SOUTH BOUND DF DIRECT FIXATION SCL SEATTLE CITY LIGHT GENERAL SYMBOLS TYPICAL EQUIPMENT PAD NTS DIA,0 DIAMETER SCH SCHEDULE DIM DIMENSION SE SOUTHEAST DIST DISTANCE SEM SEQUENTIAL EXCAVATION METHOD NOTES: DTL DETAIL SF SQUARE FEET DWG DRAWING SHT SHEET SPEC SPECIFICATION NORTH ARROW 1. ALL NOTES SHALL USE THIS FORMAT AND COORD. TOP ELEVATION PUBLIC UTILITIES E EAST EA EACH STU SEATTLE STREET J SHOULD BE LOCATED AT TOP RIGHT OF SHEET. IN FIELD W/ ST RE FOR DRAINAGE REQUIREMENTS. EG EXISTING GRADE ST RE SOUND TRANSIT RESIDENT ENGINEER EL ELEVATION STA STATION ELEC ELECTRIC, ELECTRICAL STD STANDARD ELEV ELEVATOR STL STEEL #4 @ 12 EACH WAY, MID DEPTH EOP EDGE OF PAVEMENT STRUCT STRUCTURE EQN EQUATION SW SOUTHWEST EQ EQUAL EQUIP EQUIPMENT TBD TO BE DETERMINED DESIGNATION ° EXIST EXISTING TBM TUNNEL BORING MACHINE (NUMBER FOR DETAIL) MIN 5" AT SH CONDENSER TEMP TEMPORARY DETAIL, ELEVATION OR SECTION ' X ( LETTER FOR ELEVATION OR SECTION) _ ' • • OR PER HVAC MANUFACTURER'S RECOMMENDATIONS. FA FIRE ALARM THK THICK FF FINISH FLOOR THRU THROUGH SCALE: i � III f I I III III III III ( I I II II FH FIRE HYDRANT T/LR TOP LOW RAIL )X DRAWING NUMBER OF SHEET FG FINISH GRADE TPSS TRACTION POWER SUB STATION I III III III III III III III III II WHERE THIS IS SHOWN DRAWING NUMBER OF SHEET INDICATING WHERE THIS NOTES: FO FIBER OPTIC TRK TRACK FRVVY FREEWAY FS FLOATING TYP TYPICAL NG SLAB IS REFERENCED DESIGNATION 1. CONCRETE WORK SHALL CONFORM TO CHAPTER 19 OF IBC CONCRETE MIX SHALL BE 3,000 psi fc AT 28 DAY TEST. WATER/CEMENT RATIO SHALL BE 0.45 MEASURED BY WEIGHT AIR ENTRAINMENT SHALL BE BETWEEN 4.5 AND 7.5% FT FOOT, FEET UG UNDERGROUND FUT FUTURE UNO UNLESS NOTED OTHERWISE US UNITED STATES G GAS UTIL UTILITY GPS GLOBAL POSITIONING SYSTEM DETAIL, SCALE: ELEVATION DESIGNATION DASH THE SAME OR FOR SECTION REFERENCE SHEET ONLY ON X (NUMBER FOR DETAIL) _ (LETTER FOR ELEVATION OR SECTION) ( 1 DESIGNATION REQUIREMENTS. REINFORCING STEEL SHALL BE ASTM A 615 GRADE 60 DEFORMED BARS. DIMENSIONS OF EQUIPMENT PADS SHALL BE: 2. - 30 X 46 INCHES AT SPLIT SYSTEM EXTERIOR UNIT - DIMENSION OF EQUIPMENT PLUS SIX INCHES ALL SIDES AT PACKAGE UNITS - OR PER MANUFACTURES INSTALLATION REQUIREMENTS, WHICHEVER IS GREATER. PAD SHALL BE POURED MONOLITHICALLY AND SHALL BE 3. FLUSH WHERE ADJACENT TO AN EXISTING CONCRETE PAD. GV GAS VALVE VERT VERTICAL GVL GRAVEL VIF VERIFY IN FIELD HORIZ HORIZONTAL W WEST, WATER HT HEIGHT W/ WITH HWY HIGHWAY W/O WITHOUT WPWSDOT WORKPN IBC INTERNATIONAL BUILDING CODE WASHINGTO-RTMENT IE INVERT ELEVATION OF TRANSPORTAOINTSTATE INV INVERT WY WAY IRG IRRIGATION X-ING CROSSING JOC JOB ORDER CONTRACTOR X-OVER CROSSOVER ---- IOI�DEPAEViE D FOR CODE COMPLIANCE APPROVED JUL 01 2015 (LETTER) (NUMBER) X PREPARE SUB GRADE BY REMOVING ALL DEBRIS AND ANY X-SECT CROSS SECTION KC(M) KING COUNTY (METRO) City of Tukwila m... - %ma CO° \ 4. SOFT OR ORGANIC MATERIAL. GRADE SHALL BE EVEN & LEVEL BUILDING DIVISION PRIOR TO CONCRETE PLACEMENT. LF LINEAR FEET - DRAWING NUMBER OF SHEET DRAWING NUMBER OF SHEET WHERE THIS IS SHOWN WHERE THIS IS SHOWN (DASH IF ON SAME SHEET ONLY) (DASH IF ON SAME SHEET ONLY)P* LG LENGTH LLRT LINK LIGHT LT LEFT RAIL TRANSIT A, y F�':Ci=lL�EU CITY OF T CWILA JUN 2 9 2015 PERMIT CENTER DESIGNED BY: D. TIMPSON . �v ING �0 {koff ti LINE IS 1" AT I FULL SCALE ,,,•r: SCALE: NO SCALE HVAC MODIFICATIONSINSTRUMENT HOUSES DRAWING No.. SM0036-GZO3 DRAWN BY: of WAsyl c�� Consulting Engineers FILENAME: NON -CRITICAL HOUSES 4� �w G ��,� n W. MAIPID , , � �' �` 1601 Fifth Avenue, Suite 1600 r 4 "rLOCATION SM0036GZ03.dwg ID: CHECKED BY: �, .�/.� -:� Seattle, Washington 98101-3665 9 SOUNDTRANSIT CONTRACT No.: GENERAL NOTES, ABBREVIATIONS (206) 622-5822 Fax (206) 622-8130 T. BRUCE ,�� 3g538 �,, o� �,� �s �w ,`° CN 0056-15 AND SYMBOLS, GENERAL DETAILS SHEET No.: REV: FS E� GS ,. 4,6, DATE: APPROVED BY: rnL ��' NA SUBMITTED BY: DATE: REVIEWED BY: DATE: 03 0 No. DATE DSN CHK APP REVISION S.ROBERTS D. TIMPSON 05/8/15 B. ALAVI 05/8/15 05/8/15 0 cd 0 0 0 cc ) 0 0 co ro- O O cn z 0 co 0 U U U (n O oci Lu ao N Lr) LIF) o WELD TO FLOOR GND STUD DOOR DOUBLE 36" SIDE "3" HVAC CONTROLLER WELD TO FLOOR GND STUD POWER CABLE ENTRY 0 0 0 0 0 0 0 00 0 m 30"MIN. 0 tad Li.. \---TRANSFER SWITCH GENERRATOR PLUG LOAD CENTER HOUSE POWER LOAD CENTER SIGNAL POWER UPS BYPASS SWITCH -DISCONNECT SWITCH 0 0 7 0 LJ- SIDE "C" ;ice co L 1- 0 0 0 IL 0 (TYPICAL) 30" MIN. 36" DOOR 0) S3 SIDE "A" HVAC EQUIPMENT LAYOUT: SOUTH 133RD STREET SCALE: 3/4"=1'-0" (0 0 as (TYPICAL) 27" MIN. 0 0 13- 1- 0 PANEL FIRE ALAR A m 0 • 73 0 -J 0 0.1 0 CC 0 (TYPICAL) 34" MIN. 00 1 30"MIN. FOLD —UP nr s L. DES,, NEW EVAPORATOR F:ACK C33-ACU-01 NEW CONDENSER C33-ACC-01 3'-10" NOTES: 1. SEE GENERAL NOTES SHEET SM-0037-GZ03. 2. CONTRACTOR TO PROVIDE JOC PROPOSAL FOR PROTECTION OF NEW CONDENSER UNIT AND ASSOCIATED CONDUIT FROM VANDALISM OR THEFT SUCH AS CAGE, FENCING, BURIAL OF CONDUIT OR OTHER METHOD IN COORDINATION WITH ST RE. 3. ST ROW: REVIEW CIVIL AS-BUILTS THAT LOCATE CONCRETE PAD. 4. CONTRACTOR TO COORDINATE LOCATION OF NEW CONDENSER WITH EXISTING UTILITIES INCLUDING IRRIGATION. 5. DASHED LINE INDICATES MANUFACTURER'S RECOMMENDED CLEARANCES FOR INTAKE EXHAUST OR INSTALLATION/MAINTENANCE ACCESS. VENT FAN 36" DOOR SIDE "D" TELEPHONE WALL ---MOUNTED NEW EQUIPMENT MOUNTING PAD PER GZ03, TYP NOTE 2 REVIEWED FOR - CODE COMPLIANCE APPROVED JUL 01 2015 City of Tukwila BUILDING DIVISION RECEV4ED CITY OF TUK`WILA DESIGNED BY: D. TIMPSON DRAWN BY: W. MAIPID CHECKED BY: T. BRUCE No. DATE DSN CHK APP REVISION APPROVED BY: S.ROBERTS Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED BY: D. TIMPSON DATE: 5/8/15 REVIEWED BY: B. ALAVI w z J FULL SCALE SOUNDTRANSIT DATE: 5/8/15 SCALE: NO SCALE FILENAME: SM0036_CP08.dwg CONTRACT No.: CN 0056-15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES HVAC EQUIPMENT LAYOUT SOUTH 133RD STREET JUN 2 9 2015 PERMIT CENTER DRAWING No.: SM0036-CP08 LOCATION ID: SHEET No.: REV: 11 0 CI al o O cn cn J_ LL 0 J VJ J L w 0 cn 0 d f- 0 2 0 M 2 o n. M i M _ U N- 0 o Q- o I - INTERIOR FIRE BARRIER SEAL 1/ EX. GALVANIZED STEEL EXTERIOR STRUCTURE EX. RIGID INSULATION NEW CONDUIT FOR ELECTRICAL - SEE ELECTRICAL DRAWINGS EXTERIOR SEALANT EX. PLYWOOD WITH FIRE -RATED LAMINATE TYPICAL WALL PENETRATION - ELECTRICAL CONDUIT SCALE: 3" = 1'-0" INTERIOR FIRE BARRIER SEAL NOTES: 1. SEE NOTES ON DETAIL 1 FOR NOTES IN COMMON 2. DX LINES MUST NOT CONTACT WALL INSULATED DX LINE PER MECHANICAL DRAWINGS EXTERIOR SEALANT 1/4" FIBERGLASS INSULATION TYPICAL WALL PENETRATION - DX LINE SCALE: 3" = 1'-0" NOTES: 1. CONTRACTOR TO TOUCH-UP PAINT AT AREAS OF NEW WELDING WORK. 2. PAINT TO MATCH EXISTING. DESIGNED BY: K.KARCKHECK DRAWN BY: R.TRAN CHECKED BY: D. NELSON No. DATE DSN CHK APP REVISION APPROVED BY: B. TISCARENO Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 TISCARENO ASSOCIATES ARCHITECTURE+ URBAN DESIGN LINE IS 1" AT FULL SCALE SOUNDTRANSIT SCALE: 3"= 1'-0" FILENAME: SM0036 AD01 CONTRACT No.: CN 0056-15 SUBMITTED BY: D. TIMPSON DATE: 5/8/15 REVIEWED BY: B.ALAVI DATE: 5/8/15 DATE: HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES 5/8/15 ARCHITECTURAL DETAILS REVIEWED FOR CODE COMPLIANCE TROVT J01 2 CfTukBUILG DION CITY OF TO,WiLA JUN 29 2015 PERMIT CENTER DRAWING No.: SM0036-AD01 LOCATION ID: SHEET No.: 18 REV: 0 A C • H MECHANICAL LEGEND CAD User: cschifferl. No. GENERAL SYMBOL 0 • EF-1 SECTION SCALE: SECTION SCALE: DETAIL X X SCALE: DETAIL SCALE: DATE 1 XX XX� DUCTWORK TRANSITIONS DUCT BRANCH TAKE -OFFS: d DSN 45° CHK DESCRIPTION HEAVY LINE INDICATES NEW WORK LIGHT LINE INDICATES EXISTING WORK OR BACKGROUND CENTERLINE KEY NOTE CALLOUT REVISION CALLOUT POINT OF CONNECTION EQUIPMENT CALLOUT, SEE SCHEDULE INDICATES DIAMETER OR ROUND SECTION DESIGNATION (LETTER) DRAWING NUMBER OF SHEET WHERE THE SECTION IS SHOWN DRAWING NUMBER OF SHEET WHERE THE SECTION IS CUT SECTION DESIGNATION (LETTER) SECTION CUT ON THE SAME SHEET ONLY SECTION DESIGNATION (LETTER) DRAWING NUMBER OF SHEET WHERE THE SECTION IS SHOWN (DASH IF ON THE SAME SHEET ONLY) DETAIL DESIGNATION (NUMBER) DRAWING NUMBER OF SHEET WHERE THE DETAIL IS SHOWN DRAWING NUMBER OF SHEET INDICATING WHERE THE DETAIL IS REFERENCED DETAIL DESIGNATION (NUMBER) DETAIL REFERENCED ON THE SAME SHEET ONLY DETAIL DESIGNATION (NUMBER) XX/"'�- DRAWING NUMBER OF SHEET WHERE THE DETAIL IS SHOWN (DASH IF ON SAME SHEET ONLY) h= 1 /4"w OR h= 6"MINIMUM h= 1/4"d OR h= 6"MINIMUM APP REVISION OR 45° 45° DUCT SIZE TRANSITIONS: 15° (TYP) ALL DUCT TRANSITIONS ANGLES SHALL NOT EXCEED 15° h= 1/4"d OR h= 6"MINIMUM APPROVED BY: M. STAVIG VENTILATION DOUBLE SINGLE 24x12+ �----� r I'xa x l +F+ z IIIIIIIIIIIIIIIIIIIIIII i DESCRIPTION DUCT: 1ST SIZE (IN) INDICATES SIDE SHOWN, 2ND SIZE (IN) INDICATES SIDE NOT SHOWN, INSIDE FREE AREA SUPPLY AIR DUCT - TURNING UP OR TOWARD SUPPLY AIR DUCT - TURNING DOWN OR AWAY RETURN OR EXHAUST AIR DUCT OR TOWARD RETURN OR EXHAUST AIR DUCT OR AWAY ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING DOWN OR AWAY TRANSITION TRANSITION - ROUND TO RECTANGULAR - TURNING UP - TURNING DOWN TURNING VANES IN RECTANGULAR DUCT TURN 90° ELBOW (RADIUS = 1.5 x ELBOW DIAMETER) RECTANGULAR BRANCH CONNECTION WITH 45° TAPER CONICAL BRANCH CONNECTION 45° LATERAL FITTING 45° LATERAL FITTING WITH 45° ELBOW 90° CONICAL TEE FITTING BAROMETRIC RELIEF DAMPER VOLUME DAMPER BACKDRAFT DAMPER COMBINATION FIRE/SMOKE DAMPER (PROVIDE DUCT ACCESS PANEL) INDICATES RISE OR DROP IIIIIIIIIIIIIIIIIIIIIIII FLEXIBLE DUCTWORK +lir+t III t FLEXIBLE CONNECTOR CEILING DIFFUSER (FOUR-WAY AIRFLOW) RETURN/EXHAUST GRILLE Ar EQUIPMENT SYMBOL DESCRIPTION 0 D THERMOSTAT OR TEMPERATURE SENSOR (120V, 1 PHASE) CONTROL WIRING/TUBING (BY ELECTRICAL) MOTORIZED DAMPER AND ACTUATOR (120V, 1 PHASE) PLUMBING AND PIPING SYMBOL CD DESCRIPTION CONDENSATE DRAIN Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED: D. TIMPSON DATE: 5/8/15 ABBREVIATIONS ACU AFF ARCH BDD BHP CARTRG CD CENT CFM CH CLG CONC COND CONN CONT DB DDC DIA DISCH DN EA EAT EG EF EFF ELEV ENT ESP EXIST (E) EXT F FCO FD FHR FPM FT FV GAL HP IN KW LAT LBS LF LVG MANUF MAX MBH MCA MIN MOD NC NO OFCI OSA PD POC PRESS PSI PSIG RG RH RM RPM C D i ‘-A MAZZETi'I 19203 36th Ave. W, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 www.MAZZETTI.com APPROVED: B. ALAVI AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ARCHITECTURAL BACKDRAFT DAMPER BRAKE HORSEPOWER CARTRIDGE CEILING DIFFUSER CENTRIFUGAL CUBIC FEET PER MINUTE CABINET HEATER CEILING CONCRETE CONDENSATE (INSULATED) CONNECTION CONTINUATION DRAIN DRY BULB DIRECT DIGITAL CONTROL DIAMETER DISCHARGE DOWN EXHAUST AIR ENTERING AIR TEMPERATURE EXHAUST GRILLE EXHAUST FAN EFFICIENCY ELEVATOR ENTERING EXTERNAL STATIC PRESSURE EXISTING EXTERNAL FAHRENHEIT FLOOR CLEANOUT FLOOR DRAIN/FIRE DAMPER FIRE HOSE REEL FEET PER MINUTE FEET FACE VELOCITY GALLONS HORSEPOWER INCHES KILOWATT LEAVING AIR TEMPERATURE POUNDS (WEIGHT) LINEAR FOOT LEAVING MANUFACTURER MAXIMUM BRITISH THERMAL UNIT PER HOUR (THOUSAND) MINIMUM CURRENT AMPACITY MINIMUM MOTOR OPERATED DAMPER OR MODEL NOISE CRITERIA NORMALLY OPEN OR NUMBER OWNER FURNISHED CONTRACTOR INSTALLED OUTSIDE AIR PRESSURE DROP POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAGE RETURN GRILLE RELATIVE HUMIDITY OR RELIEF HOOD ROOM REVOLUTIONS PER MINUTE SOUNDTRANSIT DATE: 5/8/15 SCALE: NO SCALE FILENAME: SM0036 MZ01 CONTRACT NO.: CN 0056-15 DATE: 5/8/15 ABBREVIATIONS (CONT) SCL SP SEC SFD SG SH SO STE TEMP TG TSP TPSS TYP V VIB VEL VERT VOL VOLT W WB WSEC SEATTLE CITY LIGHT STATIC PRESSURE SEATTLE ENERGY CODE SMOKE/FIRE DAMPER SUPPLY GRILLE SIGNAL HOUSE SCREENED OPENING SOUND TRANSIT ENGINEER TEMPERATURE TRANSFER GRILLE TOTAL STATIC PRESSURE TOTAL STATIC PRESSURE TYPICAL VENT VIBRATION VELOCITY VERTICAL VOLUME VOLTAGE WASTE/WATT WET BULB WASHINGTON STATE ENERGY CODE Is',00 DRAWING INDEX SM0036-MZ01 SM0036-MZ02 SM0036-MZ03 SM0036-MH01 SM0036-MH02 SM0036-MH03 SM0036-MH04 SM0036-MH05 SM0036-MH06 SM0036-MH07 SM0036-MH08 SM0036-MH09 SM0036-MH10 MECHANICAL LEGEND AND ABBREVIATIONS GENERAL NOTES AND ENERGY CODE MECHANICAL EQUIPMENT SCHEDULES, CONTROL SEQUENCE AN SIGNAL HOUSE EQUIPMENT PLAN - ROYAL BROUG SIGNAL HOUSE EQUIPMENT PLAN - STADIUM SIGNAL HOUSE EQUIPMENT PLAN - SOUTH HOLGA SIGNAL HOUSE EQUIPMENT PLAN - SOUTH LANDE SIGNAL HOUSE EQUIPMENT PLAN - YARD NORTH SIGNAL HOUSE EQUIPMENT PLAN - YARD SOUTH SIGNAL HOUSE EQUIPMENT PLAN - BOEING REVIEWED FOR gitQFLVVIPLIANCE M APPROVED JUL 01 2015 City of Tukwila BUILDING DIVISION ;.,,_.1 L 0 CITY OF TUKWILA SIGNAL HOUSE EQUIPMENT PLAN - SOUTH 133RD STREETJUN 2 9 2015 SIGNAL HOUSE EQUIPMENT PLAN - TUKWILA SIGNAL HOUSE EQUIPMENT PLAN - AIRPORT PERMIT CENTER HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES MECHANICAL LEGEND AND ABBREVIATIONS DRAWING NO.: SM0036-MZ01 LOCATION ID: SHEET NO.: 19 REV: 0 A 0 • Ci v • CAD User: cschifferl. GENERAL NOTES 2012 WASHINGTON STATE ENERGY CODE 2012 SEATTLE ENERGY CODE 2012 SEATTLE ENERGY CODE (CONT) 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING 1. HVAC EQUIPMENT SHALL HAVE MINIMUM PERFORMANCE AT SPECIFIED RATING 13. ALL AIR SYSTEMS SHALL BE PROVIDED WITH A 100% CAPABLE AIR ECONOMIZER DRAWINGS, DIAGRAMS, AND AS DESCRIBED IN SPECIFICATIONS. CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE C403.2.3(1)A CONDITIONS NOT LESS THAN THE VALUES INDICATED IN TABLE C403.2.3(1)A CAPABILITY AS REQUIRED BY THE SECTION C403.3.1 AND C403.4.1 OF THE 2. INSTALL ALL MECHANICAL WORK AS HIGH AS POSSIBLE, TIGHT TO THROUGH C403.2.3(1)D, C403.2.3(2), C403.2.3(3), C403.2.3(4), C403.2.3(5), C403.2.3.(7), C403.2.3(8), C403.2.3(9) AND C403.2.3 OF THE WSEC AND AS THROUGH C403.2.3(1)D, C403.2.3(2), C403.2.3(3), C403.2.3(4), C403.2.3(5), C403.2.3.(7), C403.2.3(8), C403.2.3(9) AND C403.2.3 OF THE SEC AND AS SEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. STRUCTURE ABOVE OR ADJACENT WALLS. INDICATED ON THE CONTRACT DOCUMENTS. INDICATED ON THE CONTRACT DOCUMENTS. 14. AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET 3. THE MECHANICAL PLANS ARE DIAGRAMMATIC IN NATURE AND DO NOT 2. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF 2. PROVIDE DEADBAND BETWEEN HEATING/COOLING SPACE SENSOR SETPOINTS OF THE REMAINDER OF THE COOLING LOAD AS REQUIRED IN SECTION C403.3.1.1.2 ATTEMPT TO SHOW ALL REQUIRED OFFSETS. REFER TO GENERAL, ARCH- BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK AND ALSO 5 DEGREES AS REQUIRED BY SECTION C403.2.4.2 OF THE SEC OR AS OF THE SEC. ITECTURAL AND STRUCTURAL DRAWINGS FOR CONSTRUCTION DETAILS. ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. 15. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER 4. ITEMS NOTED "TYPICAL" OR "TYP" ON ANY SHEET APPLY TO THAT REQUIRED BY SECTION C403.2.4.3 OF THE WSEC AND AS DESCRIBED IN THE 3. HVAC SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC CONTROLS CAPABLE OF C403.2.10.3 AND SECTION C403.2.13 OF THE SEC FOR FULL LOAD PARTICULAR SHEET. TEMPERATURE CONTROL SEQUENCES. BEING SET FOR SEVEN DIFFERENT DAY TYPES PER WEEK AND ALSO EFFICIENCIES. 5. COORDINATE WITH SPECIFICATIONS. IN CASE OF CONFLICT BETWEEN 3. OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING ACCOMPLISHING SETBACK OR SHUTDOWN DURING UNOCCUPIED PERIODS AS 16. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY SPECIFICATIONS AND DRAWINGS THE MORE STRINGENT SHALL APPLY. CONDITIONED SPACES SHALL BE EQUIPPED WITH MOTORIZED DAMPERS AS WITH THE REQUIRED BY SECTION C403.2.4.3 OF THE SEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. SECTION C408.1.3.1 OF THE SEC. THE DRAWINGS SHALL INDICATE THE LOCATION 6. PROVIDE NEC CODE MINIMUM HORIZONTAL AND VERTICAL WORKING REQUIRED BY SECTION C403.2.4.4 OF THE WSEC AND SHALL COMPLY DAMPER LEAKAGE REQUIREMENTS. AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF CLEARANCES FOR ALL ELECTRICAL PANELS AND EQUIPMENT. OFFSET 4. OUTSIDE AIR INTAKES, EXHAUST OUTLETS AND RELIEF OUTLETS SERVING DUCTWORK AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS MECHANICAL WORK AS REQUIRED. 4. COOLING SYSTEMS SHALL BE EQUIPPED WITH OPTIMUM START CONTROLS PER CONDITIONED SPACES SHALL BE EQUIPPED WITH MOTORIZED DAMPERS AS A MINIMUM. 7. COORDINATE ALL MECHANICAL WORK WITH THAT OF OTHER TRADES TO SECTION C403.2.4.3.3 OF THE WSEC. REQUIRED BY SECTION C403.2.4.4 OF THE SEC AND SHALL COMPLY WITH THE DAMPER LEAKAGE REQUIREMENTS PER SECTION C402.4.5 OF THE SEC• 17. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER INSURE PROPER AND ADEQUATE INTERFACE OF THEIR WORK WITH THE 5 PROVIDE BALANCING DAMPERS, TEMPERATURE AND PRESSURE TEST CONNECTIONS AS REQUIRED BY SECTION C408.1.3.2 OF THE SEC AND AS SPECIFIED. WORK OF THIS CONTRACTOR. PROVIDE COORDINATED SHOP DRAWINGS AND BALANCING VALVES IN ALL AIR SUPPLY OUTLETS, BRANCH DUCTS AND PIPE 5. HEATING AND COOLING SYSTEMS SHALL BE EQUIPPED WITH AUTOMATIC START 18. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2.1 AND PRIOR TO FABRICATION AND INSTALLATION. RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2 OF THE WSEC CONTROLS PER SECTION C403.2.4.3.3 OF THE SEC. C408.2.2.2 OF THE SEC AND AS SPECIFIED. 8. VERIFY EXISTING CONDITIONS BEFORE COMMENCING ANY WORK ON AN AND AS INDICATED ON THE CONTRACT DOCUMENTS. 6. PROVIDE BALANCING DAMPERS, TEMPERATURE AND PRESSURE TEST CONNECTIONS 19. COMMISSIONING SHALL BE PROVIDED AND REPORT OF COMMISSIONING BE SUB - EXISTING MECHANICAL SYSTEM. 9. COORDINATE EXACT LOCATIONS OF ALL ROOM THERMOSTATS AND/OR ROOM TEMPERATURE SENSORS WITH OWNER PRIOR TO INSTALLATION. 6. ALL DUCTWORK SHALL COMPLY WITH SMACNA STANDARDS FOR CONSTRUCTION OF GALVANIZED DUCTWORK. ALL DUCTWORK SHALL BE SEALED AS REQUIRED BY SECTION C403.2.7 OF THE WSEC. DUCT TAPE NOT ALLOWED. AND BALANCING VALVES IN ALL AIR SUPPLY OUTLETS, BRANCH DUCTS AND PIPE RUNS TO TERMINAL DEVICES AS REQUIRED BY SECTION C408.2.2 OF THE SEC AND AS INDICATED ON THE CONTRACT DOCUMENTS. MITTED TO THE OWNER AS REQUIRED BY SECTION C408 OF THE SEC. COMMISSIONING SHALL CONSIST OF A COMMISSIONING PLAN, BALANCING, FUNCTIONAL PERFORMANCE TESTING, POST CONSTRUCTION COMMISSIONING, 10. PROVIDE ADEQUATE CLEARANCES FOR DOWNSPOUTS AND DRAINAGE OF DUCTWORK STATIC PRESSURE AND SEAL CLASS: 7. ALL DUCTWORK SHALL BE CONSTRUCTED AND SEALED PER IMC, C402 LEAKAGE REQUIREMENTS AND IBC VAPOR RETARDER REQUIREMENTS AS REQUIRED BY TRAINING, REPORTS, ACCEPTANCE AND COMMISSIONING COMPLIANCE CHECKLIST. RAINWATER WHEN LOCATING AC UNITS. COORDINATE CONCRETE PAD WATER COLUMN SEAL CLASS SECTION C403.2.7.1 AND C403.2.7.3 OF THE SEC. LOCATIONS FOR AC MOUNTING WITH STE IN FIELD. 1/2 TO 3 INCHES SEAL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS SEAMS AND 11. ROUTE ALL DX PIPING ON WALLS OR ROOFS TO AVOID IMPACT DAMAGE FROM ABOVE 3 INCHES SEAL TRANSVERSE, JOINTS, LONGITUDINAL DUCT WALL PENETRATIONS DUCTWORK STATIC PRESSURE AND SEAL WATER COLUMN SEAL CLASS CLASS: VEHICLES AND TO AVOID ELECTRICAL, EQUIPMENT CLEARANCES AND ACCESS 7 DUCTWORK SHALL BE TESTED AS REQUIRED BY SECTION C403.2.7.3.3 OF THE 1/2 TO 2 INCHES SEAL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS REQUIREMENTS. WSEC. PROVIDE TEST REPORTS TO THE OWNER. ABOVE 2 INCHES SEAL TRANSVERSE, JOINTS, LONGITUDINAL SEAMS AND 12. ALL SPACE THERMOSTAT WIRING AND CONDUIT BY ELECTRICAL CONTRACTOR. 8. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.7 OF DUCT WALL PENETRATIONS 13. AC UNITS AND SPLIT SYSTEM UNITS TO BE STAND ALONE CONTROLS. THE WSEC AND AS DESCRIBED IN THE PROJECT MANUAL. 8. DUCTWORK SHALL BE TESTED AS REQUIRED BY SECTION C403.2.7.3.3'OF THE 14. ROUTE ALL CONDENSATE DRAINS AWAY FROM STRUCTURE AND UNIT, 9. ALL PIPING SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8 AND TABLE SEC. PROVIDE TEST REPORTS TO THE OWNER. CONCRETE PADS APPROXIMATELY 12" MINIMUM. ALL DRAINS TO BE C403.2.8 OF THE WSEC AND AS DESCRIBED IN THE PROJECT MANUAL. 9. ALL DUCTWORK SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.7 OF INSULATED, REFER TO DRAWINGS. 10. INDIVIDUAL ZONE TERMINAL UNITS AND HVAC SYSTEMS SERVING PORTIONS OF THE SEC AND AS DESCRIBED IN THE PROJECT MANUAL. 15. REPLACE ALL EXISTING MAKE-UP AIR AND VENT FAN, FILTERS WITH NEW THE BUILDING HAVING LESS THAN 24-HOUR OPERATION OR DIFFERENT USES DUCT TYPE LOCATION R-VALUE/U-FACTOR FILTERS. SHALL BE SHUT OFF OR SET BACK DURING UNOCCUPIED PERIODS AS REQUIRED BY SECTION C403.2.4 OF THE WSEC AND AS DESCRIBED IN THE TEMPERATURE DUCTS/SHAFTS/ FROM EXTERIOR OF THE U-0.055 (MEET AIR CONTROL SEQUENCES. PLENUMS BUILDING TO THE MECHANICAL SYSTEM LEAKAGE AND BUILDING ENVELOPE VAPOR CONTROL 11. SUPPLY AIR AND WATER TEMPERATURES SHALL BE AUTOMATICALLY RESET AS (CONVEYING OUTSIDE AIR) REQUIREMENTS OF IBC) REQUIRED IN SECTION C403.4.3.4 AND C403.4.5.4 OF THE WSEC OR AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. SUPPLY/RETURN/ PLENUMS UNCONDITIONED SPACES R-6 12. ALL AIR SYSTEMS SHALL BE PROVIDED WITH A 100% CAPABLE AIR ECONOMIZER SUPPLY/RETURN/ OUTSIDE OF THE BUILDING R-8 CAPABILITY AS REQUIRED BY THE SECTION C403.3.1 AND C403.4.1 OF THE PLENUMS WSEC AND AS DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES. SUPPLY WITH WITHIN CONDITIONED SPACE R-3.3 13. AIR AND WATER ECONOMIZERS SHALL BE CAPABLE OF PROVIDING PARTIAL SUPPLY TEMP COOLING EVEN WHEN ADDITIONAL MECHANICAL COOLING IS REQUIRED TO MEET < 55°F OR > 105°F THE REMAINDER OF THE COOLING LOAD AS REQUIRED IN SECTION C403.3.1.1.2 OF THE WSEC. 10. ALL PIPING SHALL BE INSULATED AS REQUIRED BY SECTION C403.2.8 AND TABLE 14. MOTOR EFFICIENCY SHALL NOT BE LESS THAN THE MINIMUM CALLOUTS PER C403.2.8 OF THE SEC AND AS DESCRIBED IN THE PROJECT MANUAL: C403.2.10.3 AND SECTION C403.2.13 OF THE WSEC FOR FULL LOAD INSULA- MEAN PIPE DIAMETER: EFFICIENCIES. TEMP (°F) TION CON- RATING <1" 1"TO<1-1/2" 1-1/2"TO<4" 4"TO<8" >8" 15. RECORD DRAWINGS SHALL BE PROVIDED TO THE OWNER AS REQUIRED BY DUCTIVITY TEMP (°F) INSULATION THICKNESS: SECTION C408.1.3.1 OF THE WSEC. THE DRAWINGS SHALL INDICATE THE LOCATION AND PERFORMANCE DATA OF EQUIPMENT, GENERAL CONFIGURATION OF DUCTWORK ABOVE 350 .32-.34 250 4.5 5.0 5.0 5.0 5.0 AND PIPING DISTRIBUTION SYSTEMS, INCLUDING FLOW RATES AS A MINIMUM. 251-350 201-250 .29-.32 .27-.30 200 150 3.0 2.5 4.0 2.5 4.5 2.5 4.5 3.0 4.5 3.0 16. OPERATION AND MAINTENANCE MANUALS SHALL BE PROVIDED TO THE OWNER 141-200 .25-.29 125 1.5 1.5 2.0 2.0 2.0 AS REQUIRED BY SECTION C408.1.3.2 OF THE WSEC AND AS SPECIFIED. 105-140 .21-.28 100 1.0 1.0 1.5 1.5 1.5 17. HVAC SYSTEMS SHALL BE BALANCED AS REQUIRED BY SECTION C408.2.2.1 AND 61-104 .21-.28 75 1.0 1.0 1.5 1.5 1.5 C408.2.2.2 OF THE WSEC AND AS SPECIFIED. 40-60 .21-.27 75 0.5 0.5 1.0 1.0 1.0 BELOW 40 .20-.26 75 0.5 1.0 1.0 1.0 1.5 18. COMMISSIONING SHALL BE PROVIDED AND REPORT OF COMMISSIONING BE SUB- MITTED TO THE OWNER AS REQUIRED BY SECTION C408 OF THE WSEC. NOTE: PIPING INSULATION MEETS OR EXCEEDS SEC. W - COMMISSIONING SHALL CONSIST OF A COMMISSIONING PLAN, BALANCING, 10a. PIPING INSULATION EXPOSED TO WEATHER SHALL BE PROTECTED FROM DAMAGE REV6EWED FOR FUNCTIONAL PERFORMANCE TESTING, POST CONSTRUCTION COMMISSIONING, AS REQUIRED BY SECTION C403.2.8.1 OF THE SEC AND AS DESCRIBED IN THE CODE COMPLIANCE TRAINING, REPORTS, ACCEPTANCE AND COMMISSIONING COMPLIANCE CHECKLIST. PROJECT MANUAL. APPROVED 19. COOLING SYSTEMS HAVE BEEN SIZED IN ACCORDANCE WITH SECTION C403.2.2 OF 11. INDIVIDUAL ZONE TERMINAL UNITS AND HVAC SYSTEMS SERVING PORTIONS OF JUL 0 1 2015 THE WSEC. THE BUILDING HAVING LESS THAN 24-HOUR OPERATION OR DIFFERENT USES SHALL BE SHUT OFF OR SET BACK DURING UNOCCUPIED PERIODS AS REQUIRED City of Tukwila BY SECTION C403.2.4 OF THE SEC AND AS DESCRIBED IN THE TEMPERATURE BUILDING DIVISION CONTROL SEQUENCES. 12. SUPPLY AIR AND WATER TEMPERATURES SHALL BE AUTOMATICALLY RESET AS F177.:3:::.r.N.10 REQUIRED IN SECTION C403.4.3.4 AND C403.4.5.4 OF THE SEC OR AS CITY OF T UkWILA DESCRIBED IN THE TEMPERATURE CONTROL SEQUENCES.( JUN 2 9 2015 3 ....... 0 PERMIT CENTER Mw+ �rv+r � d�pPo.",fu.^.ry�."V.w ".Spr. ,fi4r,.au I..I q.r,".'.,,r.,.u"d, �:r:,x,.C.,.�.7o., o,,:r:! .. 1.Je.aN.x:,..,.",:.mxw'arr+:.r.: :.r :n.�'.4mm.:. ',:,:.. ;,.9w..,r::' . . h,.w.,.mP..k:!,r:".,.,,.:R.:,,4,:.,,-:. ., , ,mmu . r N'reui'ry wJ+'d!w t .« . . .:xWd.r , :I,. ,.1 ..Is: M rI': ,.w 1,.1G .ar.»& .dv,r1, I .a:t\1,m.v „D.._M,xx.e.w..:'w,r::,:I.49a.. '.". ,:,:r1..„t�...„M:,..:.r..:,,..n..:.,., .,r:.7:,,..:.,.•...NIn:wM......i.. . ,a,: ,.r:,, 'd rvn ra.aNdd.,w1wrh r!r.:,ih u :�Ia:,, .,.a1C I,"r..x �, .I , I.....Er,d1Yn !:.„.',.,",� .1.,..... :;,,,.r.:.:G.r:.f.,f. w'...,.r,,,.,m,., ..,.,Y..:^..:.s 1.. :,..�d,....�:..,,w.,.:..nw.::. ,:. .. I a.:, t .pn +. .yrv,vC,d 1r nJxotln;.tht ...,ti.VYr.W",w .�Xkw, ai #",xaPrI'q,..P". , 1'r,1 ^. .,Ir.. .a^>., , 1.,, rvr„.Y,"j.nGra.v,.:vr.ti',....7,.4.„..I;.x..:n.,.r":.r.. Y^.�{.,,:n,",d:,,:::,ri.,:z.x.,rx.,y, , ,a,,.:. :.,„^1.k.,h, ,.d .b a !, l xd. nm.d hA,I,n.'L Av::Sr,.r.„,r.e,:x,,.„ ,C. r. ,,,: I: ,,.,.. A r. ,.a. x.,:..,V.h.,"r.:h•.r.vrv,;. .,,r x\.,.:.:,,, ..mP,,. , ' .; „ :. , ..^MY.I � :r+,, k ,qxI �v, °,„..r,u,,:i::, .,,:,r,.,, , ,...I. „..i...r.,:x:,:I,..!.,r,r:..,..,�„.x,.... x ,,.0 .z.,.. s r4rr, !<,t M ,.,: «• .,. „ "ti b h `I.,W4..kM gA,3xi"..."':vl✓ P,A!M1{,rwnx.r,wa,.:fr. ra...,^.,,.;1,.i'.:".,.:p,:.m"...M.vr,..ro..,,..,,..,,^...ro,..:..,''..m::'.d.::. r, ,d r apr l' dk.d>JG r.r,,w.:,..a.,.w.:,,.:d...,:,:,.NIi.: k,.,V . .:I �.rr. raN ✓.t.„AsC o, r1,,..,,I:.,rnrw.,„re, .. ,n,,„ ,.xd;: . ..,w.,d?, ,myy:f,...1;./Iw:o,: .',.,'f ,o�,.:.FC1o,.,.:,..npC?'::..x..„:.v,nr.,.„.r,,:.x .W1. .^ r n,I a .y M r ,rux xai'.>x. ",r� .aMqw, r.'AI:G1d,„Ind,w..�,x' .ri, .:",:,,Vv,Y,!„.,,,w,..: ....x :. .,1 cw,,a"Wa.q....aP.x~:~. .',;wn..„.nl::,:r .'Irr..,.,,:..fr:>w.:,..�, Mr.:iati.i C,x:+M .:.i cr n',r,1 ,xIa.PP:i..wa,r h\"wdd ,7aw,4rtts.r.,Wv i,,P ,s.x.�rd., .�,.P. 1r,Y:"„..t;. ,e.": r.. a ..,r... G:a,..r.:w:r.,:h.w,..,...,,.,:':,,....1:aN..:",:P..„.: ti..r,..:.,.,, : ,r aa.,r M ,:av:�r �^1`.l:t..xrr.x:,"°..,,^xIwf^.ki. n.1.,,1.d..w,.^i."nw.,.�.:. ,,r ..r..:rw:.n .{, n:.x : .,w,; .b,,rr.::).� :.R:{." ," :. :. ..^.. ..... a". .....I.ar,,91 .,P,.!:n::n..."i. :e,.,,,.,4d:.«. , fl.PA.. .6x d,. „Y. �?:�P.0:~ ammd I fm!ir..rr .�+rAu, i"Fw,,r' �,r, ,a ",. arca:a4.,�5r''.w.�a*,w,�„wr. Y .°. w u: tCe..:.,.f. .ar,,. naYfI,.„i, ,i.1r,,W:i..,r....w.^.I ,\!n^... 1...,,,:.:., :...:.:F,,:"':r .: ... .M"YMrGx.Cx ,N ^, "Iir �1 I DESIGNED BY. J. DELLA � ,., ,,. �� r...,; ., .' k®ff �DIyaA� Consulting Engineers 19203 36th Ave. W Suite 1601 Fifth Avenue, Suite 1600 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 - _Q w WQNO J , SCALE: SCALE HVAC MODIFICATIONSINSTRUMENT HOUSES .' SM0036 - MZO2FILENAE.��c1 200 1+ w �''o �f Aft' . DRAWN BY. S. WOOD M SM0036 MZ02 NON CRITICAL HOUSES LOCATION ID: pa 24672 ..410.rSTS ,, Seattle, Washington 98101-3665 www_MAZZETTI.com (206) 622-5822 Fax (206) 622-8130 Z _u_SOUNDTRAVSIT CONTRACT NO.: CN 0056-15 GENERAL NOTES AND ENERGY CODE MECHANICAL CHECKED BY: M. STAVIG SHEET NO.: REV: 20 0 APPROVED BY: SUBMITTED: DATE: APPROVED: DATE: DATE: ` 11Cs +t-3 No. DATE DSN CHK APP REVISION M. STAVIGA�� D. TIMPSON 5/8/15 B. ALAVI 5/8/15 5/8/15 A • • • H CAD User: cschifferl. Xref Filename: No. DATE DSN CHK SEQUENCE OF OPERATIONS SPLIT AIR CONDITIONING UNIT UNITS SHALL BE PROVIDED WITH REMOTE PROGRAMMABLE CONTROLS TO TURN UNIT ON AT SPACE TEMPERATURE SETPOINT OF 80°F (ADJUSTABLE). EXISTING UNIT VENTILATORS TO TURN OFF AT 75°F AND DAMPERS TO CLOSE VENT. UNITS TO TURN ON AGAIN AT 72°F (ADJUSTABLE). VENTILATION FAN AND AIR CONDITIONING UNITS TO BE INTERLOCKED TO PREVENT SIMULTANEOUS OPERATION. DX PIPING OUTDOOR CONDENSER INDOOR EVAPORATOR CONTROL N. WIRING BY CONTROLS CONTRACTOR SPACE TEMPERATURE SENSOR/CONTROLLER SPLIT SYSTEM UNIT CONTROL - CONTROL DIAGRAM SCALE: N.T.S. APP REVISION DESIGNED BY: J. DELLA DRAWN BY: S. WOOD CHECKED BY: M. STAVIG APPROVED BY: M. STAVIG EXTERIOR VENTILATION FAN INTERLOCK WIRING BY CONTROLS CONTRACTOR SPACE TEMPERATURE SENSOR/CONTROLLER Consulting Engineers 1601 Fifth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED: D. TIMPSON DATE: 5/8/15 CDI + AZZET I 19203 36th Ave. W, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425.778.8769 www. MAZZ ETT I . co m APPROVED: B. ALAVI AIR CONDITIONING UNITS - SPLIT SYSTEM MARK LOCATION ACU ACU SEE PLANS SEE PLANS CAPACITY TYPE SPLIT SPLIT NOM CLG: TONS 2.0 3.0 NET CLG: MBH 24.0 34.2 SEER 17.0 14.0 REFRIGERANT R-410 R-410 CONNECTIONS SUCTION LINE: IN 5/8 5/8 LIQUID LINE: IN 3/8 3/8 DRAIN: IN 3/4 3/4 INDOOR SECTION LOCATION SEE PLANS SEE PLANS AIRFLOW: CFM (HIGH) 775 920 ESP: IN WG 0.2 0.2 MOTOR HP - - ELEC HEAT: KW - - FILTER TYPE DISPOSABLE DISPOSABLE WEIGHT: LBS 46 46 VOLT/PHASE 208/1 208/1 FLA 0.36 0.57 MCA 1.0 1.0 OUTDOOR SECTION (ACC3 AND ACC4) LOCATION SEE PLANS SEE PLANS WEIGHT: LBS 163 163 VOLT/PHASE 208/1 208/1 MCA 18.0 25.0 ELECTRICAL SCCR: AMPS 10,000 10,000 BASIS OF DESIGN MANUFACTURER MITSUBISHI MITSUBISHI MODEL (INDOOR) PKA-A24KA PKA-A36KA MODEL (OUTDOOR) PUY-A24NHA3 PUY-A36NHA3 NOTES [1, 2, 3, 4, 5, 6] [1, 2, 3, 4, 5] NOTES: 1. REFER TO ELECTRICAL DRAWINGS FOR DISCONNECT SWITCHES. 2. OUTDOOR UNITS MOUNTED ON CONCRETE PADS WITH VIBRATION ISOLATION PADS. 3. ROUTE 3/4" CONDENSATE DRAIN TO OUTDOORS, SEE PLANS. AVOID DISCHARGE NEAR OUTDOOR UNIT. CONDENSATE DRAINS TO BE INSULATED. 4. PROVIDE WITH WIRED MICROPROCESSOR 24/7 PROGRAMMABLE THERMOSTATIC CONTROLLER. LOW VOLTAGE WIRING AND CONDUIT BY ELECTRICAL CONTRACTOR. 5. MAXIMUM DX PIPING LENGTH = 165 FT. MAXIMUM DX PIPING HEIGHT = 100 FT. 6. UNITS INSTALLED IN C12, C14 AND C16 SIGNAL HOUSES ONLY. SOUNDTRANSIT DATE: 5/8/15 SCALE: NO SCALE FILENAME: SM0036 MZ03 CONTRACT NO.: CN 0056-15 DATE: 5/8/15 isoo; 1 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES EQUIPMENT SCHEDULES, CONTROL SEQUENCE AND DIAGRAM REVIEWED FOR LTOTI ODE COMPLIANCE 1 TuDN f s::;�'li`U CITY OF TUicWILA JUN 2 9 2015 PERMIT CENTER DRAWING NO.: SM0036-MZ03 LOCATION ID: SHEET NO.: 21 REV: 0 A • • c • • CAD User: cschifferl. Path: H:\2015\156-027 — ST TO 45 Non Critical Signal Houses\Dwg\SM0036_MH08.dwg Plot date: May 07, 2015-03: 40: 49pm Xref Filename: I GZ_TB_SM0036 NEW REMOTE SENSOR THRM2 WELD TO FLQO GND STUD DOOR DOUBLE SIDE " HVAC CONTROLS ft NEI. D TO FLOOR GND STUD POWER CABLE ENTRY DE 5! tif) :\ \',...; A HTLI,„ LI- c— grAvo 3 CAL`) MIN. PANEL ALARM NEW CONDENSER C33-ACC-01 SIGNAL HOUSE EQUIPMENT PLAN: SOUTH 133RD STREET 1 SCALE: 3/4"=1'-0" SM0036-MH08 LAI t \ (TYPICAL) \J MIN. CA/ 30,1 THRM1 N. T FAN DOOR SIDE D" NEW EVAPORATOR C33-ACU-01 NOTES: O FOLD —UP n,l !T SIC NTEGRAL PLAN RACK TELEPHONE WALL —MOUNTED CONCRETE PAD, SEE GZO3 INDOOR EVAPORATOR MOUNTED ON WALL. ELECTRICAL ITEMS TO BE REMOVED AND RELOCATED BY ELECTRICAL CONTRACTOR. COORDINATE EXACT LOCATION OF UNIT IN FIELD. OUTDOOR UNIT MOUNTED ON CONCRETE PAD WITH VIBRATION ISOLATION PADS. COORDINATE EXACT LOCATION IN FIELD. ROUTE CONDENSATE DRAIN THROUGH WALL TO 6" ABOVE GRADE. EXTEND AWAY FROM BUILDING 12" AND ELBOW DOWN. VENT FAN TO SHUT-OFF AT 75°F AND 0.10" WEIGHTED DOOR VENT BACKDRAFT DAMPE TO CLOSE. ACC AND ACU TO START AT 80°F AND RUN 30 MINUTES MINIMUM PRIOR TO SHUTTING DOWN. VENT FAN AND DOOR VENT TO START AND OPEN AT 72°F. REFER TO TO CONTROLS SEQUENCE AND DIAGRAM FOR FURTHER DETAIL. 0 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 01 2015 City of Tukwila BUILDING DIVISION DX SUCTION AND LIQUID LINES UP ON WALL SUPPORT ON WALL. PENETRATE WALL AND CONNECT TO EVAPORATOR ACU. SUPPORT PIPE WITH ENRICO PYRAMID PIPE SUPPORTS FASTENED TO ROOF AND PER MANUFACTURER'S RECOMMENDATIONS. 0 18"Wx30" 0.10" WEIGHTED BACKDRAFT DAMPER. MOUNT OVER EXISTING DOOR VENT. REMOVE EXISTING DOOR COVER. ENSURE FILTER REMAINS. ® DOOR VENT DAMPER TO OPEN WITH VENT FAN OPERATION. '1I5OO8 ( R'CE1'JED CITY OF TUKWILA JUN 2 g 2015 PERMIT CENTER DESIGNED BY: J. DELLA DRAWN BY: S. WOOD CHECKED BY: M. STAVIG No. DATE DSN CHK APP REVISION APPROVED BY: M. STAVIG Consulting Engineers 1601 F7fth Avenue, Suite 1600 Seattle, Washington 98101-3665 (206) 622-5822 Fax (206) 622-8130 SUBMITTED: D. TIMPSON DATE: 5/8/15 CD I + MAZZETI" I 19203 36th Ave. W, Suite 200 Lynnwood, WA 98036 T 425.672.1071 F 425 778 8769 www. MAZZETTI . com APPROVED: B. ALAVI w FULL SCALE SOUNDTRANSIT DATE: 5/8/15 SCALE: 3/4"=1'-0" FILENAME: SM0036 MH08 CONTRACT NO.: CN 0056-15 DATE: 5/8/15 HVAC MODIFICATIONS INSTRUMENT HOUSES NON -CRITICAL HOUSES SIGNAL HOUSE EQUIPMENT PLAN SOUTH 133RD STREET DRAWING NO.: SM0036-MH08 LOCATION ID: SHEET NO.: 29 REV: 0