Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M15-0147 - HENSEN HERBS - EXHAUST HOOD AND FAN
HENSEN HERBS 768 INDUSTRY DR M15-0147 Parcel No: Address: Project Name: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 2523049008 768 INDUSTRY DR HENSEN HERBS MECHANICAL PERMIT Permit Number: M15-0147 Issue Date: 11/17/2015 Permit Expires On: 5/15/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: NCWP ANDOVER EXECUTIVE PARK 810 NW MARSHALLS ST #300 , PORTLAND, WA, 97209 STEVEN BAKER 109 WASHINGTON BLVD, STE B , ALGONA, WA, 98001 FIVE STAR MECHANICAL 109 WASHINGTON BLVD, SUITE B , ALGONA, WA, 98001 FIVESM*010JT III Phone: (253) 852-8284 Phone: (253) 852-8284 Expiration Date: 5/1/2016 DESCRIPTION OF WORK: MOVE AND REINSTALL EXHAUST HOOD AND FAN Valuation of Work: $4,913.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $258.96 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 C � f t(( Permit CenterAuthorized Signature: Date: -1''( ,S I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:(/(4,`.--- Print Name: ✓ A (_ A/1 Cj co (I Date: WI / 1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***MECHANICAL PERMIT CONDITIONS*** 9: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** ATION., Site Address: 768 Industry drive, Tukwila, WA. Tenant Name: Hensen Herbs King Co Assessor's Tax No.: 2523049008 Suite Number: 768 Floor: 1 New Tenant: ❑ Yes ..No Name: Premier renovations Address: 19419 SE 240th St. City: Covington State: wa Zip: 98042 Name: Steven Baker Address: 109 wa blvd. ste b City: algona State: wa Zip: 98001 Phone: (253) 852-8284 Fax: (253) 852-8285 Email: service@fivestarmech.com O Company Name: Five Star Mechanical Address: 109 Washington Blvd. Ste. B City: Algona State: wa Zip: 98001 Phone: (253) 852-8284 Fax: (253) 852-8285 Contr Reg No.: FIVESM*006C3 Exp Date: Tukwila Business License No.: BUS-09929977 Valuation of project (contractor's bid price): $ 4,913 Describe the scope of work in detail: kAnQ Ve AA r'' Q $ fGt H A U tioOd Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement ❑ Fuel Type: Electric m Gas ❑ Other: H:WpplicationsWorms-Applications On Line\2011 ApplicationsUvlechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: nit;'Ty t. Q.ty Furnace <100k btu Furnace >I00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Uu'it Type Qt Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct 1 Incinerator — domestic Incinerator — comm/industrial Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment /Comp 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). [ HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN OR AUTHORIZED AGENT: Signature: c2� ! E Date: 11/03/2015 Print Name: Steven Baker Day Telephone: (253) 852-8284 Mailing Address: 109 WA BLVD ST B Algona wa 98001 City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila Receipt Number R6573 DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $258.96 M15-0147 Address: 768 INDUSTRY DR Apn: 2523049008 $258.96 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $166.70 PLAN CHECK FEE R000.322.102.00.00 0.00 $49.80 TECHNOLOGY FEE $9.96 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R6573 R000.322.900.04.00 0.00 $9.96 $258.96 Date Paid: Tuesday, November 03, 2015 Paid By: STEVEN BAKER Pay Method: CREDIT CARD 392174 Printed: Tuesday, November 03, 2015 1:40 PM 1 of 1 C�SYSTEMS INSPECTION RECORD Retain a copy with permit jri1Y� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: i% ! leA 2C€4, .755 Type of Inspe tion: - ""C'. 'i'-'4 Addddress: �/ ) Date Called: ���a.rri Special Instructions: / Date Wanted: Requester: e ibiki'U., Phone No: a_S 3 4 .s' .166 Approved per applicable codes. l.__J Corrections required prior to approval. COMMENTS: 4r67)7 �c> Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD /�l� �� Retain a copy with permit INSP CTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Vc Project: P �, �? � Type of Inspe lion: — 4— Ad Address:. Z h/ DR. Date Called: // Special Instructions: i A.A..1 Date Wanted: ! . Requester: Phone No: Approved per applicable codes. D Corrections required prior to approval. COMMENTS: /1/0t pro vk Q R# , - For- fDS' q- C h/. l gc9 p pr©Uf0 i 1 c id, f I ns pecto enzeiv%w=7 - Date: /f /Os REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1 2 3 4 5 6 7 8 9 10 A I '3 v $eaTac 1 ©4j I 16:-¢s 'SIN IIi11 Bellevue Menu, 1, and Renton, kwila 768 Industry Dr Newcastle Cascade- Fanwood JOB LOCATION VICINITY MAP a NTS NORTH SITE PLAN NTS O D NORTH M R Wdd East Pe Utopia Her WORK LOCATION J MECHANICAL LEGEND SYMBOL DESCRIPTION ABBREV. DESCRIPTION ABBREV. DESCRIPTION - c - CONDENSATE LINE (C) AHJ ABBREV APPROX ARCH BTU BTUH BLDG CAP CKT COP COMP CONN CONT CFM DEF, F DIA 0 DN DWG DB EA ECON ELEC ELEV EAT EWB EDB EXIST. (E) ESP FLA HP AUTHORITY HAVING JURISDICTION ABBREVIATION APPROXIMATELY ARCHITECTURAL BRITISH THERMAL UNIT BRITISH THERMAL UNIT/HOUR BUILDING CAPACITY CIRCUIT COEFFICIENT OF PERFORMANCE COMPRESSOR CONNECTION CONTINUE, CONTINUATION CUBIC FEET PER MINUTE DEGREE FAHRENHEIT DIAMETER DOWN DRAWING DRY BULB EACH ECONOMIZER ELECTRICAL ELECTRIC ELEVATION ENTERING AIR TEMPERATURE ENTERING WET BULB ENTERING DRY BULB EXISTING EXTERNAL STATIC PRESSURE KW LAT LDB MT LWB MAX MFR MBH MCA MECH MIN MOCP NTS OSA PH PD POC RLA REF REQD RA RPM RM SA TEMP TYP V W/ KILOWATT LEAVING AIR TEMPERATURE LEAVING DRY BULB LEAVING WATER TEMPERATURE LEAVING WET BULB MAXIMUM MANUFACTURER THOUSAND BTUH MINIMUM CIRCUIT AMPS MECHANICAL MINIMUM MAXIMUM OVER CURRENT PROTECTION NOT TO SCALE OUTSIDE AIR PHASE PRESSURE DROP POINT OF CONNECTION RATED LOAD AMPS REFERENCE REQUIRED RETURN AIR REVOLUTIONS PER MINUTE ROOM SUPPLY AIR TEMPERATURE TYPICAL VOLTS, VOLTAGE, VENT WITH rut rlirl FLEXIBLE CONNECTION _ DUCT SECTION (SUPPLY) ht.,'DUCT SECTION (EXHAUST OR RETURN) O THERMOSTAT dam— DETAIL IDENTIFICATION NUMBER SHEET ON WHICH DETAIL IS SHOWN SHEET WHERE DETAIL CALLOUT IS LOCATED taut at SECTION IDENTIFICATION LETTER SHEET ON WHICH SECTION IS SHOWN �_- FULL LOAD AMPS HORSE POWER ROOFTOP EXHAUST FAN SCHEDULE MECHANICAL DEBIGNER8. LLC li ALTE (253) 228JJ91 _wad- -*AA** eegiyofir C0Q1/$BICML HVAC • EN�iE��•` '! REVIEWED FO CODE COMPLIAt 3APPROVED _NO\ 0 6 2015 tVJ R JCE City of Tukwila BUDDING DIVISION SYMBOL SPECIFIED MANUFACTURER AND SERIES NO. TYPE AREA SERVED CFM ESP RPM ELECTRICAL HP VOLTS/PH DRIVE CONTROL. MAX WEIGHT IN LBS REMARKS EF-1 ILC # CROA-15 EXHAUST CENTRIFUGAL • ROOFTOP LOCATION FOR EXHAUST BELOW 100 .260• 1160 O 120/1 DIRECT 125 SONES 12.2 - SPEED CONTROL FOR BALANCING INSIDE WAREHOUSE EF-2 ILC # CRDA-15 EXHAUST CENTRIFUGAL • ROOFTOP LOCATION FOR EXHAUST BELOW • WAREHOUSE VENTILATION - FAN EX11AUST REPLACEMENT - UKE FOR UKE I VITIS I No changes 3ha`I be made to the scope of r srk withol;t prior approval of FILE COPY Permit Na (‘AI�J • ��� Plan review approval is subject to errors and orn Approval r ti ¶;onstruction documents does not a the violation of any adopted code or ordinance. of approved Field popy and conditions is acknowiedgod: By: Data: 11/i BUILDING- DI iSION 125 SONES 12.2 - SPEED CONTROL FOR BALANCING INSIDE WAREHOUSE SCOPE OF WORK -1. LLREMOVE EXISTING EXHAUST FANS ON ROOF. 2. 25E-USE EXISTING FAN/ROOF CURBS FOR NEW FANS. NEW �0FFANS ARE SAME SIZE 8 CAPACITY OF OLO FANS. 3. RE -CONNECT EXHAUST DUCT TO EXHAUST DUCT BELOW ROOF. 4. RE -CONNECT ELECTRICAL AND FAN SPEED CONTROLLER LOCATED IN WAREHOUSE SPACE BELOW (TYPICAL BOTH EXHAUST FANS). s;onS DRAWING INDEX horn a MECHANICAL LEGEND. NOTES A SCHEDULES �M1.0 EXISTING BUILDING ROOF PLAN Receipt RECEIVED CITY OF TUKWILA NOV 0 3 2015 PERMIT CENTER 5 6 7 8 9 NI5OL'7 a PERMIT SET LEGEND, NOTES & SCHEDULES CHECKED: JE & MT FILE NO. 15-188 MO.0 r SHEET SIZE IS TRUE SCALE WHEN ABOVE UNEMEASURESAS NOTED A 1 R 1 c 1 D I F F I H A B E F 2 3 4 5 6 7 8 9 10 EXISTING BLDG AERIAL PHOTO FOR CONTRACTOR USE NTS 1013 DUCT. PENETRATE THRU ROOF, WEATHER SEAL 8'0 DUCT, PENETRATE THRU ROOF. WEATHER SEAL NORTH EXISTING ROOF O 8-0 DUCT THRU ROOF. WEATHERSEAL /p 10'0 DUCT THRU ROOF WEATHERSEAL 81 I (E) WALLS BELOW (TVP) 23 — 1 —ion-- Po:k k a1oc r he fi,LA0 Ytel.41 6otr1' to caM ��� oxini�g ;Iajci S ys4erM - 1 EXISTING ROOF DEMOLITION NOTES: ,A REMOVE (E) EXHAUST FANS FROM (E) CURB AND DETACH FROM (E) EXHAUST DUCT CONNECTION BELOW ROOF. CONSTRUCTION NOTES: 0 PREPARE (E) CURB FOR RE -USE TO INSTALL NEW EXHAUST FANS) ONTO CURB. THE SAME WAY OLD FANS WERE INSTALLED PER FIELD OBSERVATION. INSTALL NEW FANS ON CURB, RECONNECT TO EXHAUST DUCT BELOW ROOF. RE -CONNECT ELECTRICAL AND TO SPEED CONTROLLER INSIDE WAREHOUSE. 0 BUILDING CONFIGURATION IS APPROXIMATE AND PER GOGGLE EARTH AERIAL VIEW. OCLARITY. OTHER (E) ROOFTOP EQUIPMENT IS NOT SHOWN FOR PROJECT SCOPE j41o6-1_, �Oe.ING 4-e4 ,� 2A BUILD`� a N EXISTING BLDG ROOF PLA- HVAC ab SCALE: AS INDICATED NORTH RECEIVED CITY OP TUKWILA NOV 0 3 205 PERMIT CENTER 9 10 2 3 VtlT TY ;�. ( 5 6 REVIEWED FOR CODE R®VED OE PLIAN AP NOV 0 6 2015 7 City of Tukwit� DIVISION MECHANICAL DESIGNERS, LLC KENT. WA 98031 DIRECT (253) 951-1502 ALTO (263)238I391 FIVE STAR MECHANICAL COYBICMLHVAC WMENANCE-SERVICE CONSTRUCTION -CONTROLS ENERGY CONSERVATION HENSEN HERBS 0 z CHECKED: JE & MT PROJECT NO. EC-15-5STAR-002HH 1/3 C30 FILE NO. 15-188 M1.01 A 1 R 1 I I) F I F r H I PERMIT SET TRUE SCALE WHEN ..SURES AS NOTED PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0147 PROJECT NAME: HENSEN HERBS SITE ADDRESS: 768 INDUSTRY DR DATE: 11/03/15 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: -a U Building Division Public Works ❑ o�M It1� Fire Prevention Structural Isp< ort Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 11/05/15 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Corrections Required n Denied (ie: Zoning Issues) (corrections entered in Reviews) Approved with Conditions DUE DATE: 12/03/15 n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 FIVE STAR MECHANICAL Page 1 of 2 Home lrncio en Espanol Contact. Search L&I. 1 A-7 Index Help My Secure Safety Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries FIVE STAR MECHANICAL Owner or tradesperson Principals WARE, GERALD LAVON, MEMBER WARE, JOHN EDWARD, MEMBER ALLEN, ANGELA RENEE, MEMBER WARE, BETTY J, MEMBER Doing business as FIVE STAR MECHANICAL WA UBI No. 601 937 083 109 WASHINGTON BLVD STE B ALGONA, WA98001 253-852-8284 KING County Business type Corporation License Verify the contractors active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. FIVESM*010JT Effective — expiration 04/30/1999— 05/01/2016 Bond ...._.......... Western Surety Co Bond account no. 62031473 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 05/16/2014 04/27/2014 Expiration date Until Canceled Bond history Insurance ........................ AMCO Ins Co $1,000,000.00 Policy no. acp3016636020 Received by L&I Effective date 04/23/2015 04/27/2015 Expiration date 04/27/2016 Insurance history Savings ..................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings httos://secure.lni.wa.2ov/verify/Detail.aspx?UBI=601937083&LIC=FIVESM*010JT&SAW= 11/17/2015