Loading...
HomeMy WebLinkAboutPermit M15-0156 - TWIN PEAKS - MECHANICAL SYSTEMTWIN PEAKS 17920 SOUTHCENTER PKWY M15-0156 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 3523049123 17920 SOUTHCENTER PKWY Project Name: TWIN PEAKS Permit Number: Issue Date: Permit Expires On: M15-0156 6/1/2016 11/28/2016 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MADISON INVESTMENTS LLC P 0 BOX 1922 , BOZEMAN, CO, 59771 ALEX KANAPILLY 3333 S BANNOCK ST, STE 340, ENGLEWOOD, CO, 80110 K & D MECHANICAL INC 33530 1ST WAYS #102, FEDERAL WAY, WA, 98003 KDMECI*008CJ Phone: (303) 886-6219 Phone: (253) 945-8204 Expiration Date: DESCRIPTION OF WORK: INSTALLATION OF NEW MECHANICAL SYSTEM ASSOCIATED WITH NEW RESTAURANT Valuation of Work: $0.00 Type of Work: Fuel type: Fees Collected: $1,801.42 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: HIGHLINE Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 �g tO11 Permit Center Authorized Signature: ittt w Date: 1 I t I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws re latin ns uction or the performance of work. I am authorized to sign and obtain this development per and. r the conditions attached to this permit. /4 9 rlh /11-eS p6`i%.A✓ Signature: Print Name. Date: 6-1! LJ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 2: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 3: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 4: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 5: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437) 6: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 7: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 10: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 11: All new automatic fire -extinguishing systems and all modifications to existing automatic fire -extinguishing systems shall have fire department review and approval of drawings prior to installation or modification. 12: Local U.L. central station supervision is required. (City Ordinance #2437) 13: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 14: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 15: Portable fire extinguishers shall be provided within a 30-foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 16: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 20: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 21: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 22: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 23: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 24: Readily accessible access to roof mounted equipment is required. 25: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 26: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 27: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 28: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 29: ***MECHANICAL PERMIT CONDITIONS*** 30: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 31: Manufacturers installation instructions shall be available on the job site at the time of inspection. 32: Type 1 Hoods, the required grease duct leakage test and (light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST 0710 TYPE 1 HOOD AND DUCT Tenant Name: CITY OF TUKWW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. V S Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 352304-9123 Site Address: 17920 Southcenter Pkwy Suite Number: New Tenant: Twin Peaks - Tukwila PROPERTY OWNER Name: Stovetop Restaurant Group Address: 9327 Piperhill Drive SE City: Olympia State: WA Zip: 98513 CONTACT PERSON — person receiving all project communication Name: Alex Kanapilly Address: 3333 S. Bannock Street Suite 340 City: Englewood State: co Zip: 80110 Phone: (303) 886-6219 Fax: Email: alex@precisiondsllc.com Floor: Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 13 D Describe the scope of work in detail: Installation of new mechanical system associated with the new building. Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric VI Gas m Other: H:Wpplications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 1 Floor furnace Suspended/wall/floor mounted heater 16 Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system 1 Hood and duct 1 Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: 11/20/2015 Print Name: Brad Clawson Day Telephone: (303) 501-9272 Mailing Address: 9327 Piperhill Drive SE Olympia WA 98513 City State Zip H:\Applications\Fortes-Applications On Line\201 I Applications\Mcchanical Permit Application Revised 8-9-I l.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $1,454.99 M15-0156 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $1,454.99 MECHANICAL $1,385.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $1,353.20 TECHNOLOGY FEE $69.29 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8629 R000.322.900.04.00 0.00 $69.29 $1,454.99 Date Paid: Wednesday, June 01, 2016 Paid By: JAMES DAHLEN Pay Method: CREDIT CARD 094828 Printed: Wednesday, June 01, 2016 4:23 PM 1 of 1 LlL1 UlJ SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $8,038.96 D15-0293 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $6,957.06 DEVELOPMENT $6,707.06 PLAN CHECK FEE R000.345.830.00.00 0.00 $6,707.06 PUBLIC WORKS $250.00 BASE APPLICATION FEE R000.322.100.00.00 0.00 $250.00 EL15-1018 Address: 17920 SOUTHCENTER PKWY Apn:3523049123 $486.66 ELECTRICAL $486.66 PLAN CHECK FEE R000.345.832.00.00 0.00 $486.66 M15-0156 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $346.43 MECHANICAL $346.43 PLAN CHECK FEE R000.322.102.00.00 0.00 $346.43 PG15-0136 Address: 17920 SOUTHCENTER PKWY Apn: 3523049123 $248.81 GAS $83.88 PLAN CHECK FEE R000.322.103.00.00 0.00 $83.88 PLUMBING $164.93 PLAN CHECK FEE R000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R6698 0.00 $164.93 $8,038.96 Date Paid: Friday, November 20, 2015 Paid By: JB CLAWSON Pay Method: CREDIT CARD 04897D Printed: Friday, November 20, 2015 2:38 PM 1 of 1 INSPECTION RECORD Retain a copy with permit INSP ION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 ect: a (IL Type of Ins?dn: Idepi ic)Date 5611414—Ctr kW .e. Called: Special Instructions: / Date Wanted: -f� a.m. p.m. Requeste : Phone No: Approved per applicable codes. L� Corrections required prior to approval. COMMENTS: Inspector: Kc_,/ Date. 0 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: ( � v( / ZJi,�1 l eAKS Type of�Inspection: cmoie�i _,�.�+ b- I Address:re+�`� ,�' i l-l20 scv! -3a ifl PY&'i Date Called: Special Instructions: Date Wanted / G am.. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. OMMENTS: Inspector:)(...e., Date, 2 ,6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD _ Retain a copy with permit IN..- TION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: n /,-BA/ P AKC Type of Inspection: r4r I-vourA-t_ F7Ab' L Address: lu //1X10 PVir-Al Date Called: Special Instructions: Date Wanted / //6 / Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: c� h4l f I�tc I e r t i�o u i `silo t ,c `,,, � (� .,� L, l {C .ct lw Cc..l-'Ls. �/ ,o. 1 ( °f �`a✓ c( / 4c S' fsrrt_og' Ate C.hi A do ,, tuc146, C(( r re4 s (Q ti Inspector: Date: 41`Z®/.6 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. ramINSPECTION RECORD Retain a copy with permit CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /l fj'O(J Pr 'ect:, t� �TypQpf Ins, tion;A A dyes #1y� ' litftietr D7ate Called: Special Instructions: lc.'1—c.keyi o � 0 to Wanted: s '� % / j CJ a.m. p.m. Requester: Phone No: ElApproved per applicable codes. D Corrections required prior to approval. COMMENTS: Inspector: Date: e REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. If INSPECTION RECORD etain a copy with permit ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Mir vic6 Proj�ec : IGJ/J PL4/'s Tyke of Inspection t16E4 JAI 11 cc/d Address: /7920 ..traili5orae Peiav Date Called: Special Instructions: n �4I +-Ikk-l- #Z Date Wang ./cl a.i p.m. Requester. Phone No: 0 Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: Datea( `r n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit lam. °IC-6 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 i� Project: -70/Ai PI A4X.( Type of Inspection: Pi Pg/Dt�c,r d , o. Address: /7926 IIJn ee:orae Pkwy Date Call d: Special Instructions: T� �"� 11 D-S Date Wante �� 1 'Requester. bOAJ Phone No: Zoo-- Kg-7- CY �G ❑Approved per applicable codes. Corrections required prior to approval. COMMENTS: S jr �r Peeli L - /� C _ 4 / hi Inspector: / 1 Date/ez REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit Mir— a f .r4' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: r DV( Arie �%S Type f Inspection: RO i — ,�J` Adyes ?TX Cr liiri Date Calle : Special Instructions: �� Date Wnted: b / (�b a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: /?ritH6tf Ave64 ?' )l,U/Afar U rT}-4- 50" ) Inspector: /' Date: 6/29 /l REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. // PERMIT NUMBERS FIRE" DEPARTMENT 4A-1,/ Address: Suite #: f Special Instructions: Approved per applicable codes. Ty of Inspection:,f Contact arson:. --Corrections required prior to approval. COMMENTS: (z) c -oc Needs Shift Inspection: Sprinklers: Fire Alarm; Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Date: H $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Company Name: Address: City: State:. Zip: T.F.D. Form F.P. 113 Twin Peaks 17920 Southcenter Parkway Air Balance / Commissioning Report Test Equipment Used: Dwyer VT-140 Thermo Anemometer Ft/ Min Measurement +/-(2% Accuracy) RTU-1 Serving West Seating Open Seating 10 @ 700 Ft/ Min @ 500 CFM Total 5,000 CFM Per Plan RTU-2 Serving Center Bar Food pickup 1 @ 600 Ft/ Min @ 630 CFM Bar 6 @ 700 Ft/ Min @ 330 CFM Greeting kiosk 2 @ 650 Ft/ Min @ 400 CFM Waiting 4 @ 600 Ft/ Min @ 330 CFM Entry 1 @ 450 Ft/ Min @ 330 CFM Total 5,060 CFM Per Plan RTU-3 Serving East Seating Open Seating 10 @ 700 Ft/ Min @ 500 CFM Total 5,000 CFM Per Plan RTU-4 Serving Kitchen Hood 1 Hood 2 Hood 3 Open Kitchen Video room Men's Room Women's Room 3 @ 700 Ft/ Min @ 200 CFM 5 @ 700 Ft/ Min @ 200 CFM 5 @ 700 Ft/ Min @ 200 CFM 9 @ 700 Ft/ Min @ 200 CFM 1 @ 700 Ft/ Min @ 200 CFM 1 @ 700 Ft/ Min @ 200 CFM 1 @ 700 Ft/ Min @ 200 CFM Total 5,000 CFM Per Plan Hood-1 @ 1,200 CFM, Hood-2 @ 2,750 CFM, Hood-3 @ 2,400 CFM, Hood-4 @ 900 CFM, Hood-5 @ 600 CFM for a total exhaust of 7,850 CFM Make Up Air Unit @ 4,930 CFM Economizers OSA @ 4,000 CFM Restaurant is at a 1,080 CFM positive pressure Total space supply air 20,000 CFM + or — 5% Units are new and existing and have economizers set at 20% delivery for 4,000 CFM Minimum. Total space cooling 50-Tons Field notes: HVAC systems are Gas Packs, The unit's are controlled by Honeywell programmable thermostats. K&D Mechanical, Inc. Prepared By, James Dahlen I President 18-30-2016 z';ECEIVED '!TY OF TUKVNILJ '�6l�11T CENTER K&D Mechanical, Inc. 335301n way so. Suite # 102 Federal Way, 98003 Phone: 253-945-8204 Fax: 253-945-8205 K&D Was Wil Twin Peaks 17920 Southcenter Parkway Air Balance / Commissioning Report Test Equipment Used: Dwyer VT-140 Thermo Anemometer Ft/ Min Measurement +/-(2% Accuracy) RTU-1 Serving West Seating Open Seating 10 @ 700 Ft/ Min @ 500 CFM Total 5,000 CFM Per Plan RTU-2 Serving Center Bar Food pickup 1 @ 600 Ft/ Min @ 630 CFM Bar 6 @ 700 Ft/ Min @ 330 CFM Greeting kiosk 2 @ 650 Ft/ Min @ 400 CFM Waiting 4 @ 600 Ft/ Min @ 330 CFM Entry 1 @ 450 Ft/ Min @ 330 CFM Total 5,060 CFM Per Plan RTU-3 Serving East Seating Open Seating 10 @ 700 Ft/ Min @ 500 CFM Total 5,000 CFM Per Plan RTU-4 Serving Kitchen Hood 1 Hood 2 Hood 3 Open Kitchen Video room Men's Room Women's Room 3 @ 700 Ft/ Min @ 200 CFM 5 @ 700 Ft/ Min @ 200 CFM 5 @ 700 Ft/ Min @ 200 CFM 9 @ 700 Ft/ Min @ 200 CFM 1 @ 700 Ft/ Min @ 200 CFM 1 @ 700 Ft/ Min @ 200 CFM 1 @ 700 Ft/ Min @ 200 CFM Total 5,000 CFM Per Plan Hood-1 @ 1,200 CFM, Hood-2 @ 2,750 CFM, Hood-3 @ 2,400 CFM, Hood-4 @ 900 CFM, Hood-5 @ 600 CFM for a total exhaust of 7,850 CFM Make Up Air Unit @ 4,930 CFM Economizers OSA @ 4,000 CFM Restaurant is at a 1,080 CFM positive pressure Total space supply air 20,000 CFM + or — 5% Units are new and existing and have economizers set at 20% delivery for 4,000 CFM Minimum. Total space cooling 50-Tons Field notes: HVAC systems are Gas Packs, The unit's are controlled by Honeywell programmable thermostats. K&D Mechanical, Inc. Prepared By, James Dahlen I President 18-30-2016 K&D Mechanical, Inc. 33530 1'33530 1st way so. Suite # 102 Federal Way, 98003 Phone: 253-945-8204 Fax: 253-945-8205 K&D M°' 1Was IWO City of Tukwila Department of Community Development 5/13/2016 ALEX KANAPILLY 3333 S BANNOCK ST, STE 340 ENGLEWOOD, CO 80110 RE: Permit Application No. M15-0156 TWIN PEAKS 17920 SOUTHCENTER PARKWAY Dear ALEX KANAPILLY, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 11/20/2015, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code, every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 6/30/2016. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M15-0156 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 January 25, 2016 Department of Community Development City of Tukwila 6300 Southcenter Boulevard, Suite 100 Tukwila, WA 98188 RE: Twin Peaks Tukwila WA Permit M15-0156 17920 Southcenter Parkway To whom it may concern, Below are responses to correction comments requiring a response for the above referenced project. Building Department Plumbing Comments 1. Provide completed 2012 Washington State Nonresidential Energy Code "Mechanical" compliance form in lieu of IECC. 2012 NREC Compliance Forms is available online at: http://www.neec.net/energy-codes, (scroll down to center of page). Comcheck software shall not be accepted unless it can be demonstrated it meets the intent of WSEC. Mechanical Heat Pumps appear to not meet Washington State Energy code and EER ratings. Revise equipment schedule to show complying with SECTION C403 2012 WSEC. Changed from IECC mechanical compliance check to WSEC mechanical check. 2. Provide Captive Air mechanical sheets with the mechanical plans for kitchen hood and ducts. Captive Aire plans provided with resubmitted sheets. 3. Indicate if the gas fireplace is part of this scope of work or a separate permit. Also note that construction of coolers and freezers shall be a separate mechanical permit. Compressors for the cooler and freezer shall be on that mechanical permit. Fireplace has been removed from this scope of work. Added key note 11 to mechanical plan M1.02 noting that coolers are to be handled under a deferred submittal per comment. Sincerely, John Tinsley oIs& CORRECTION RECEIVED CITY OF TUKWILA FEB 012016 PERMIT CENTER 10495 S. PROGRESS WAY, SUITE 202: PARKER, COLORADO 80134 : PHONE 303.646.4770 : FAX 303.646.5623 City of f Tukwila Department of Community Development December 14, 2015 ALEX KANAPILLY 3333 S BANNOCK ST, STE 340 ENGLEWOOD, CO 80110 RE: Correction Letter # 1 MECHANICAL Permit Application Number M15-0156 TWIN PEAKS - 17920 SOUTHCENTER PARKWAY Dear ALEX KANAPILLY, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" to be stamped and signed. [Electronic copies shall not be approved.] (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Provide completed 2012 Washington State Nonresidential Energy Code "Mechanical" compliance form in lieu of IECC. 2012 NREC Compliance Forms is available online at: http://www.neec.net/energy-codes, (scroll down to center of page). Comcheck software shall not be accepted unless it can be demonstrated it meets the intent of WSEC. Mechanical Heat Pumps appear to not meet Washington State Energy code and EER ratings. Revise equipment schedule to show complying with SECTION C403 2012 WSEC. 2. Provide Captive Air mechanical sheets with the mechanical plans for kitchen hood and ducts. 3. Indicate if the gas fireplace is part of this scope of work or a separate permit. Also note that construction of coolers and freezers shall be a separate mechanical permit. Compressors for the cooler and freezer shall be on that mechanical permit. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 In order to better expedite your resti..-..rtta1, a 'Revision Submittal Sheet' must accom , very resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made inperson and wi not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, Rachelle Ripley Permit Technician File No. M15-0156 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0156 DATE: 02/01/16 PROJECT NAME: TWIN PEAKS SITE ADDRESS: 17920 SOUTHCENTER PKWY Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ,9-s 2---8.1 Building Division 4. Public Works n Fire Prevention Structural ❑ Planning Division Permit Coordinator u PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 02/02/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/01/16 Approved Corrections Required n Approved with Conditions Denied Ps Agi n (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M15-0156 DATE: 11/24/15 PROJECT NAME: TWIN PEAKS SITE ADDRESS: 17920 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: 171 Building Division Public Works o Fire Prevention Structural n Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/24/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Denied (ie: Zoning Issues) (corrections entered in Reviews) Notation: Approved with Conditions DUE DATE: 12/22/15 REVIEWER'S INITIALS: DATE: Permit Center Use Only � CORRECTION LETTER MAILED: 1l►vll( Departments issued corrections: BldgFire ❑ Ping D PW D Staff Initials:Y �V 12/ 18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: V / AC, Plan Check/Permit Number: /V% / O/S-‘:, ❑ Response to Incomplete Letter # 1214 Response to Correction Letter # / ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: x-ni As Project Address: / '%c 2..o u rdc F1✓TE2 PK „,/ y Contact Person: IL C , Alp) ApZ LY Phone Number: -Z3 Feb- G-2It) Summary of Revision: SEE 4r1? Jle, '$Th"s; ' RECEIVED '.I1Ltt CITY OF TUKWILA FEB 0 1 2016 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in TRAKiT on c)---4`-( 6 K & D MECHANICAL INC Page 1 of 2 Washington State Department of Labor & Industries Home Espanol Contact Safety & Health Claims & Insurance Search L&I A-Z Index I Ie1p My L&I Workplace Rights Trades & Licensing K & D MECHANICAL INC Owner or tradesperson Principals DAHLEN, JIM L, PRESIDENT DAHLEN, JAMES L, PRESIDENT DAHLEN, DEBORAH C, VICE PRESIDENT DAHLEN, JIM, AGENT KACSO, OTTO, PRESIDENT (End: 10/30/2008) DAHLEN, JIM, VICE PRESIDENT (End: 10/30/2008) Doing business as K & D MECHANICAL INC WA UBI No. 601 994 103 33530 1st way south suite#102 FEDERAL WAY, WA 98003 253-945-8204 KING County Business type Corporation Governing persons JAMIE BROCKAMP JIM L DAHLEN; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. KDMECI*008CJ Effective — expiration 02/11/2000— 02/21/2018 Bond ................. CBIC Bond account no. SJ4600 $6, 000.00 Received by L&I Effective date 01/10/2012 02/01/2012 Expiration date Until Canceled Bond history Insurance .............................. Contractors Bonding & Insuranc Policy no. $1,000,000.00 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601994103 &LIC=KDMECI * 008CJ&SAW= 6/1/2016 MECHANICAL SPECIFICATIONS H.V.A.C. LEGEND 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Cooling & Heating Equipment Schedule, Page 1 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 MECH-EQ Revised Aug 2015 Project Info The following information shall be . included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. Project Address: 17920 Southcenter Parkway Date 1/18/2016 Tukwila, WA 98188 For Building Dept. Use Applicant Name: John Tinsley Applicant Address: 38140 Fawn Meadows Trailer, Elizabeth CO 80107 Applicant Phone: 303.646.1860 Heating and/or Cooling Systems (Note 1) Cooling System Equip. ID Make & Model Area(s) Served WSEC Efficiency Table Equipment Type Condenser or Sub- Type Cooling Capacity, Btu/h (Note 2) Rated Efficiency (Note 3) Rated Part Load Efficiency (Note 4) Economizer exception - required % higher efficiency RTU-1 Carrier 50TCQD14 Dining C403.2.3(2) Unitary & Applied Heat Pumps Heat pump Air-cooled, Elec. . Res. or No Heat 136,000 12.00 10.60 RTU-2 Carrier 50TCQD14 Dining C403.2.3(2) Unitary & Applied Heat Pumps Heat pump Air-cooled, Elec. Res. or No Heat 136,000 12.00 10.60 RTU-3 Carrier 50TCQD14 Dining C403.2.3(2) Unitary & Applied Heat Pumps Heat pump Air-cooled, Elec. Res. or No Heat 136,000 12.00 10.60 RTU-4 Carrier 50TCQD14 Kitchen C403.2.3(2) Unitary & Applied Heat Pumps Heat pump Air-cooled, Elec. Res. or No Heat 136,000 12.00 10.60 MUA-1 Captive Aire A3-D.750-G18 Hoods None IRH-1-7 Schwank 2313 Exterior Patio None • EUH-1 Qmark MUH03-41 Water Entry Room None Note 1 - Enter Equip ID, Make & Model, and Location of Service in this section for all heating & cooling, cooling only and heating only equipment. Note 2 - Provide listed rated cooling capacity for rated equipment or design cooling capacity for unrated equipment. Note 3 - For rated equipment, provide listed rated efficiency in the units defined for the equipment in the WSEC efficiency table - SEER, EER, SCOP, COP 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and _> 3 story R2 and R3 Cooling & Heating Equipment Schedule, Page 2 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 MECH=EQ' Revised Aug 2015 Project Info The following information shall be included in the mechanical equipment schedules in the permit documents. For projects without plans, provide the required information below. Project Address: 17920 Southcenter Parkway Date 1/18/2016 Tukwila, WA 98188 For Building Dept. Use Applicant Name: John Tinsley Applicant Address: 38140 Fawn Meadows Trailer, Elizabeth CO 80107 Applicant Phone: 303.646.1860 Heating System Air System Equip. ID WSEC Efficiency Table Equipment Type Sub -type or Fuel Capacity, Btu/h (Note 5) Rated Efficiency (Note 6) Supply CFM Ventilation CFM Zone DCV or Occ. Sensors (Indicate type & zones(s) if required) Ventilation Energy Recovery (Yes or Not required) RTU-1 C403.2.3(2) Unitary & Applied Heat Pumps Heat pump Air-cooled, Elec. Res. or No Heat 96,000 100.00 5,000 1,500 RTU-2 C403.2.3(2) Unitary & Applied Heat Pumps Heat pump Air-cooled, Elec. Res. or No Heat 96,000 100.00 5,000 1,500 RTU-3 C403.2.3(2) Unitary & Applied Heat Pumps Heat pump Air-cooled, Elec. Res. or No Heat 96,000 100.00 5,000 1,500 RTU-4 C403.2.3(2) Unitary & Applied Heat Pumps Heat pump Air-cooled, Elec. Res. or No Heat 96,000 100.00 5,000 1,500 MUA-1 C403.2.3(4) Furnaces and Unit Heaters Warm air furnace Gas 313,000 80.00 4,930 4,930 IRH-1-7 Unrated Gas -fired Radiant Gas 50,000 80.00 - - EUH-1 Unrated Electric Strip Heat electric 10,239 100.00 - - Note 4 - For rated equipment, provide listed rated part load efficiency IEER if required by code. Provide the rated low temperature EER for water source water -to -water heat pumps. Note 5 - Enter the rated cooling capacity for heat pumps, the listed rated heating capacity for all other rated equipment, or the design heating capacity for unrated equipment. Note 6 - For rated equipment, provide listed rated efficiency and, if applicable, the low temperature rated efficiency in the units defined for the heating equipment in the WSEC efficiency table - HSPF, COP, AFUE, E-t, E-c 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MECH-SUM 2012 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Aug 2015 Project Info Project Address: 17920 Southcenter Parkway Date 1/18/2016 Tukwila, WA 98188 For Building Dept. Use Applicant Name: John Tinsley Applicant Address: 38140 Fawn Meadows Trailer, Elizabeth CO 80107 Applicant Phone: 303.646.1860 Project Briefly describe the text box Description mechanical systems in provided Bldg Performance Performance compliance all mandatory provisions per Option 2. MECH-SUM, and C407 Energy Summary forms required. Addition ❑Tenant Improvement ❑System Retrofit No System Changes powered heat pumps. ✓ New Building i Building New building with electrically El Total Total Bldg includes C401.2 MECH-CHK, Analysis Mechanical Systems Summary Equip ID Type of System (Note 1) Space(s) Served ; Compliance Path Heating and Cooling Fan Flow Controls , Air Economizer (Note 2) Ventilation' (Note 3) : Energy Recovery RTU-1 Electric Heat Pump Dining Simple single zone system Heating and cooling Two speed (TS) Yes Minimum per IMC Not Required RTU-2 Electric Heat Pump Dining Simple single zone system Heating and cooling Two speed (TS) Yes Minimum per IMC Not Required RTU-3 Electric Heat Pump Dining Simple single zone system Heating and cooling Two speed (TS) Yes Minimum per IMC Not Required RTU-4 Electric Heat Pump Kitchen Simple single zone system Heating and cooling Two speed (TS) Yes Minimum per IMC Not Required MUA 1 Make -Up Air Unit Hoods Simple single zone system Heating only Constant volume (CV) No cooling, NA Not Applicable Not Required IRH-1-7 Radiant Unit Heater Exterior Patio Simple single zone system Heating only Not applicable No cooling, NA Not Applicable Not Required EUH-1 Electric Unit Heater Water Entry Room Simple single zone system Heating only Not applicable No cooling, NA Not Applicable Not Required Note 1- Provide basic description of system type, for example: unitary rooftop air handler, built-up central air handler, single -packaged, split terminal air conditioner or heat pump; unit heater, warm -air fumace. electric resistance heater, 4-pipe fan coil, VRF system, energy make-up air system, ground or water -source heat pump, etc. Note 2 - If taking an exception to air economizer, select exception taken from drop down menu and complete MECH-ECONO form. Summary exception are listed in MECH-ECONO. Note 3 - If ventilation "Not applicable" is selected, provide explanation in Project Description box above. system or packaged recovery air handler, definitions of each HVAC Hydronic Systems ❑ Hydronic chilled water ❑ Water -loop heat pump ❑ Geothermal systems ✓ No hydronic Ill Hydronic heating Service Water Heating Systems Equipment Type (s) ❑ Hot water heating tank(s) ❑ Dedicated boiler Distribution Type (s) ❑ No service water systems a from space heat boiler or ✓ Instantaneous g ❑ exchange central hot water/steam ❑ On -demand ✓ Circulation System 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Schedules ❑ Mechanical Plans ✓ MECH-EQ Fomi Indicate location of equipment compliance information. If provided on plans then MECH-EQ forms are not required, however, include on plans all applicable compliance information listed in MECH-EQ tables. Design Load Calculations ✓ Load calculation summary ❑ MECH-LOAD-CALC Form Provide design load calculations for all mechanical systems and equipment serving the building heating, cooling or ventilating needs. If a load calculation summary is provided with the permit documents that includes all applicable compliance information then the MECH-LOAD-CALC form is not required. THE DRAWINGS INDICATE DIAGRAMMATICALLY THE EXTENT, GENERAL CHARACTER, AND LOCATION OF THE WORK INCLUDED. OFFSETS AND/OR CHANGES IN ELEVATION OF PIPING AND DUCTWORK DUE TO STRUCTURAL OR OTHER INTERFERENCES SHALL BE PROVIDED WITHOUT EXTRA COST. VERIFY AND EVALUATE ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. PROVIDE ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE AND OPERATING SYSTEM. PROVIDE CONTROL WIRING NECESSARY FOR THE OPERATION OF THE MECHANICAL SYSTEMS INDICATED ON THE MECHANICAL DRAWINGS. THiS SHALL INCLUDE, BUT NOT BE LIMITED TO, THERMOSTATS. ENTIRE NEW WORK INSTALLATION SHALL CONFORM WITH ALL APPLICABLE LAWS, CODES AND REGULATIONS OF MUNICIPAL, STATE AND FEDERAL AUTHORITIES INCLUDING: THE 2009 INTERNATIONAL BUILDING, MECHANICAL, AND ENERGY CONSERVATION CODES; ANY AND ALL LOCAL AMENDMENTS ADOPTED AND ENFORCED BY THE CITY OF PARKER, COLORADO; ASME; ASTM; ASHRAE; SMACNA; AND NFPA. WHERE REQUIRED BY CODE, ALL WORK MUST BE INSPECTED AND APPROVED BY LOCAL AUTHORITIES. PRIOR TO FINAL ACCEPTANCE, FURNISH THE ARCHITECT/OWNER WITH CERTIFICATES OF INSPECTION AND APPROVALS BY LOCAL AUTHORITIES. PROVIDE ALL DAMPER CONTROL HANDLES, ELECTRIC CONTROLS, AIR CONTROLS, MECHANICAL EQUIPMENT, AND OTHER APPARATUS THAT MUST BE PROVIDED IN AN INACCESSIBLE LOCATION WITH SUITABLE ACCESS DOORS OR COVERS IN A FRAMED OPENING, WHICH WILL PERMIT PROPER OPERATION AND SERVICING. BEFORE ACCEPTANCE AND FINAL PAYMENT, DEMONSTRATE THAT ALL APPARATUS ARE FUNCTIONING PROPERLY AND EFFICIENTLY. STARTUPS AND ADJUSTMENTS FOR THE FIRST HEATING AND THE FIRST COOLING SEASON SHALL BE INCLUDED IN THE BID. SYSTEM, MATERIAL, AND WORKMANSHIP SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR AFTER THE COMPLETION AND ACCEPTANCE. REPLACE ALL DEFECTIVE WORKMANSHIP, EQUIPMENT AND MATERIALS WITHOUT ADDITIONAL CHARGES, INCLUDING REFRIGERANT THAT IS LOST DURING RELATED REPAIRS. TESTING, ADJUSTING, AND BALANCING SHALL BE PERFORMED IN ACCORDANCE WITH THE MOST CURRENT ASHRAE HANDBOOK OF HVAC APPLICATIONS, CHAPTER 36. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO: * BALANCING AIR DISTRIBUTION SYSTEMS * ADJUSTING THE TOTAL SYSTEM TO PROVIDE DESIGN QUANTITIES * ELECTRICAL MEASUREMENT * ESTABLISHING QUANTITATIVE PERFORMANCE OF ALL HVAC EQUIPMENT * VERIFYING AUTOMATIC CONTROLS ADJUST AIR FLOWS FOR TERMINALS TO WITHIN +/- 10%. ADJUST AIR FLOWS IN DUCT MANS TO WITHIN +/- 5%, USING THE PITOT-TUBE TRANSVERSE METHOD. FURNISH TO THE ARCHITECT, FIVE (5) COPIES OF THE TESTING AND BALANCING REPORT. DUCTWORK SHALL BE GALVANIZED STEEL, CONSTRUCTED, INSTALLED, AND SUPPORTED IN ACCORDANCE WITH THE "SMACNA" APPLICABLE MANUALS. ALL DUCTWORK SHALL BE THE LOW VELOCITY TYPE, UNLESS OTHERWISE SPECIFIED. WHERE DUCTWORK IS EXPOSED TO VIEW, SUPPORT WITH THREADED ROD HANGER AND UNISTRUT. UNISTRUT SHALL HAVE (HOT -DIPPED GALVANIZED, GREEN) FACTORY FINISH. ALL DUCT TAKE -OFFS SHALL BE PROVIDED WITH A MANUAL DAMPER. SUFFICIENT MANUAL DAMPERS SHALL BE PROVIDED AND INSTALLED FOR BALANCING OF THE SUPPLY AIR SYSTEM AND THE OUTSIDE AIR/ RETURN AIR SYSTEMS. ALL EQUIPMENT SHALL BE INSTALLED IN STRICT COMPLIANCE WITH THE MANUFACTURER'S PUBLISHED INSTRUCTIONS AND SHALL PROVIDE EXTRA MATERIALS REQUIRED FOR A PROPER INSTALLATION. DUCT JOINTS FOR LOW PRESSURE DUCTWORK SHALL BE SEALED TO MEET THE SMACNA 1" W.C. PRESSURE CLASSIFICATION. SEAL ALL TRANSVERSE JOINTS WITH IRON -GRIP 601 AS MANUFACTURED BY HARDCAST. APPLY PER MANUFACTURER'S INSTRUCTIONS. DUCT TAPE IS NOT AN ACCEPTABLE MEANS OF SEALING DUCTS. EXCEPTION: DO NOT SEAL EXPOSED DUCTWORK. DUCT DIMENSIONS SHOWN ARE SHEET METAL OR WHERE LINED INTERNAL DIMENSIONS (UNLESS OTHERWISE NOTED). DUCT DIMENSIONS MAY BE CHANGED IF THE NET FREE FACE AREA IS MAINTAINED. ALL DUCT CONNECTIONS TO FAN DRIVEN UNITS SHALL BE MADE WITH 4-IN. LONG FIREPROOF FLEXIBLE DUCT CONNECTOR FOR VIBRATION SOUND ISOLATION. CONDENSATE PIPING ABOVE THE ROOF SHALL BE PVC PIPE, ASTM D 2665, SOLID -WALL DRAIN, WASTE AND VENT PIPING WITH PVC SOCKET FITTINGS COMPLYING WITH ASTM D 2665, SOCKET TYPE, MADE TO ASTM D 3311, DRAIN, WASTE, AND VENT PATTERNS. FOR EACH ROOFTOP UNIT, PROVIDE TRAP AT CONDENSATE CONNECTION AND PIPE TO NEAREST ROOF DRAIN OR SCUPPER INLET. THIS WORK SHALL BE PERFORMED IN A CLEAN AND PROFESSIONAL MANNER. CARE SHALL BE EXERCISED TO MINIMIZE INCONVENIENCE OR DISTURBANCE TO OTHER TRADES DURING CONSTRUCTION. ISOLATE WORK AREAS BY MEANS OF TEMPORARY PARTITIONS AND/OR TARPS TO KEEP DUST AND DEBRIS WITHIN THE CONSTRUCTION AREA. CLEAN THE JOB SITE DAILY AND REMOVE FROM THE PREMISES ANY DIRT AND DEBRIS CAUSED BY THE PERFORMANCE OF THE WORK INCLUDED IN THIS CONTRACT. FIELD VERIFY ALL DIMENSIONS, EXISTING CONDITIONS, AND BUILDING POWER, VOLTAGE, AND PHASE PRIOR TO ORDERING EQUIPMENT AND PROCEEDING WITH ANY WORK. WHERE DISCREPANCIES OCCUR BETWEEN THESE DOCUMENTS AND EXISTING CONDITIONS, THE DISCREPANCY SHALL BE REPORTED TO THE OWNER AND MECHANICAL ENGINEER IMMEDIATELY FOR RESOLUTION. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFEKEEPING OF HIS/HER OWN PROPERTY ON THE JOB SITE. THE OWNER OR TENANT ASSUMES NO RESPONSIBILITY FOR PROTECTION OF THIS CONTRACTOR'S PROPERTY AGAINST FIRE, THEFT, OR ENVIRONMENTAL CONDITIONS. WHERE CONDUIT, CABLES, DUCTWORK OR PIPING PASSES THROUGH FIRE RATED FLOORS, WALLS, OR PARTITIONS, THE SLEEVES SHALL BE COMPLETELY SEALED WITH A FIRE STOP MATERIAL THAT IS U.L. LISTED (EQUAL TO DOW CORNING) AND ACCEPTED BY THE BUILDING DEPARTMENT AND FIRE DEPARTMENT AS BEING SUITABLE FOR THE SERVICE. THIS MATERIAL SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S PUBLISHED INSTRUCTIONS IN ORDER TO MAINTAIN THE FIRE RATING OF THE PENETRATED WALL, FLOOR, OR PARTITION. INSTALLATION SHALL BE A THROUGH -PENETRATION FIRESTOP SYSTEM INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E 814 AND UL 1479. THE FIRE RATING SHALL MATCH THE RATING OF THE BARRIER BEING PENETRATED. SUBMIT (1) PDF FILE OR SIX (6) SETS OF SHOP DRAWINGS, CONTROL DIAGRAMS, AND EQUIPMENT CUTS TO THE MECHANICAL ENGINEER FOR APPROVAL PRIOR TO STARTING RELATED WORK. UPON COMPLETION OF CONSTRUCTION, SUPPLY THE MECHANICAL ENGINEER WITH ONE COMPLETE SET OF FULL SIZE AS -BUILT DRAWINGS AND ONE FULL SIZED PDF FILE. PROVIDE THE OWNER WITH (1) PDF AND THREE (3) SETS OF OPERATION AND MAINTENANCE MANUALS FOR EACH TYPE OF EQUIPMENT INSTALLED. SUBMISSION OF PROPOSAL IN CONNECTION WITH THIS WORK SHALL IMPLY THAT THE BIDDER HAS EXAMINED THE JOB SITE. NO EXTRA CHARGE WILL BE ALLOWED FOR CHANGES AS A RESULT FROM FAILURE TO EXAMINE THE JOB SITE. THIS CONTRACTOR SHALL SECURE AND PAY ALL FEES AND PERMITS PERTAINING TO THIS CONTRACT, SHALL BE RESPONSIBLE FOR WORKER'S IDENTIFICATION AND BADGING, SAFETY, AND LIABILITY INSURANCE. PROVIDE BARRICADES, WARNING SIGNS, AND TRASH REMOVAL FOR THE SAFETY OF THE WORKERS UNDER THIS CONTRACTOR'S EMPLOY. THIS CONTRACTOR SHALL ASSUME ALL ADDED EXPENSES TO ALL TRADES ASSOCIATED WITH THE INSTALLATION OF SUBMITTED AND APPROVED ALTERNATE EQUIPMENT. DUCT INSULATION: RECTANGULAR SUPPLY AND RETURN DUCTWORK CONCEALED ABOVE CEILINGS SHALL BE, INSULATED WITH A MINIMUM INSTALLED R-VALUE OF 6, INTERNALLY LINED WITH ACOUSTICAL LINER EQUAL TO JOHNS MANVILLE LINACOUSTIC RC FIBERGLASS DUCT LINER WITH REINFORCED COATING SYSTEM 1-1/2 INCHES THICK, R-6.3, NFPA 90A AND 90B COMPLIANT. ROUND SUPPLY AND RETURN AIR DUCTWORK CONCEALED ABOVE CEILINGS SHALL BE INSULATED WITH FIBERGLASS DUCT INSULATION WITH FSK FACING EQUAL TO JOHNS MANVILLE MICROLITE, 100# DENSITY, 2 INCHES THICK. WITH A MINIMUM INSTALLED R-VALUE OF 6. INSTALL PER MANUFACTURER'S PUBLISHED INSTRUCTIONS. DUCTWORK THAT IS ACOUSTICALLY LINED DOES NOT REQUIRE EXTERIOR INSULATION. EXTERIOR DUCTWORK SHALL BE INSULATED WITH A MINIMUM INSTALLED R-VALUE OF 8. EXPOSED DUCTWORK WITHIN CONDITIONED SPACE SHALL NOT BE EXTERNALLY INSULATED. CLEAN AND PREP FOR PAINTING (PAINT BY OTHERS). WHERE DUCTWORK IS NOTED TO BE INSULATED DIFFERENTLY ON THE DRAWINGS (i.e. EXTERNAL INSULATION ON RECTANGULAR DUCTWORK), THE CORRESPONDING INSULATION SPECIFICATIONS ABOVE SHALL APPLY. GREASE EXHAUST DUCT SHALL BE CONSTRUCTED OF 16 GAGE WELDED BLACK IRON AND SHALL BE EXTERNALLY WRAPPED IN 2 LAYERS OF U.L. LISTED GREASE DUCT WRAP UP TOP ROOF PENETRATION. HORIZONTAL GREASE EXHAUST DUCT SHALL BE PROVIDED WITH RATED CLEANOUTS PER MECHANICAL CODE. SYMBOL (E) DESCRIPTION SUPPLY DUCT UP SUPPLY DUCT DN RETURN OR EXHAUST DUCT UP RETURN OR EXHAUST DUCT DN EXISTING INSUL FLEX ROUND DUCT TRUNK DUCT ELBOW (TURNING VANES REQ'D) SYMBOL was • 12x12 DESCRIPTION SIDE CONNECTION OF ROUND DUCT TOP (OR BOTTOM) CONN OF ROUND DUCT VOLUME DAMPER (TYP) SIDE CONNECTION OF RECTANGULAR DUCT FIRE DAMPER INSIDE CLEAR INSULATION DIMENSION EQUIPMENT MARK (SEE SCHEDULES) CONNECT NEW TO EXISITNG SEPARATE PERMIT 1 �• ~QUIRRD FOR: . haniCat ltrctrjcal gliumbirtg as Piping City of Tukwila U!LP!VO DIVISION REVISIONS No changes shall e to the S of work without prior approval f o Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit N0. M 101sip. Plan review approval is sub' Approval of consiructio the violation of any a of approved Fiel to errors and omissions. ents does not authorize or ordinance. Reoe pt ditions " c cnorrtrledged: City of Tukwila BUILDING DIVISION CORRE LTR# TION RE WED FOR CODE CQMPLtANCE APPROVED FEB 18 2016 -45 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA i;jr , DESIGNPARAMI QRS, LLC 6373 SILVER STREAM LN . RISCO. TX 75034 PI -I: 214.784.5014 1=X: 303.223.9104 DESIGNPARAMI QRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80107 Phone: 303.646.1860 Fax: 303.646.5623 UTHCENTER PKWY coco START DATE • 06252015 PROJECT NO • TWP01 DRAWN BY • CHECKED BY• ISSUED/REVISED • • DATE PERMIT 11.13.2315 OVER REVSfBI.DG COMMENTS 01202018 EXPIRES: 11/15/2017 01/25J2016 MECHANICAL SPECIFICATIONS FEB 012016 PERMIT CENTER COPYRIGHT2*9 t-121i , DESIGNPARAMI QRS, LLC 6373 SILVER STREAM LN . RISCO. TX 75034 PI -I: 214.784.5014 1=X: 303.223.9104 DESIGNPARAMI QRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80107 Phone: 303.646.1860 Fax: 303.646.5623 UTHCENTER PKWY coco START DATE • 06252015 PROJECT NO • TWP01 DRAWN BY • CHECKED BY• ISSUED/REVISED • • DATE PERMIT 11.13.2315 OVER REVSfBI.DG COMMENTS 01202018 EXPIRES: 11/15/2017 01/25J2016 MECHANICAL SPECIFICATIONS FEB 012016 PERMIT CENTER COPYRIGHT2*9 t-121i ROOF MECHANICAL PLAN M1.1 SCALE: 1 /4" = 1'-0" MECHANICAL SHEET NOTES Project North 1. FIELD VERIFY FINAL PLACEMENT OF ALL ROOFTOP EQUIPMENT WITH STRUCTURAL PRIOR TO ANY WORK. MAINTAIN WORKING CLEARANCES. 2. MAINTAIN 10'-0" HORIZONTAL CLEARANCE TO ALL FRESH AIR INTAKES FROM ALL EXHAUSTS. 7 O 00 z I>< 0 00 L I>< 0 00 L I>< 1• • REVIEWED FOR CODE COMPLIANCE APPROVED FEB 18 2016 City of Tultviila BUILDING DIVISION RECEIVED CITY OF TUKWILA DCSIGNPARAMETQRS, LLC 6373 SILVER STREAM LN RISCO, TX 75034 PI-1: 214.784.5014 303.223.9104 DESIGNPARAMI QRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80107 Phone: 303.646. 7 860 Fax: 303.646.5623 CO W L1.tu) Z 's O N 1- START DATE • 08.252015 PROJECT N0• TWP01 DRAWN BY • CHECKED BY. ISSUED/REVISED • • DATE PERINT 11.182015 OMR RhVSfBLDG COAi1ENtTS 01202010 EXPIRES: 11/15/2017 01/25/2016 MECHANICAL ROOF PLAN 1 FEB 012016 a comma Zoo-ro1. 2012 IMC 507.2.1.1 OPERATION. Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. 508.1 MAKEUP AIR. For mechanical makeup air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided whenever the exhaust system is in operation. Makeup air intake opening locations shall comply with Section 401.4. Type I Hood Special Inspections Type I hoods and ducts shall be inspected by approved inspection agencies that satisfy the requirements as to qualifications and reliability. Final inspection reports from such approved agencies of the Type I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (2012 IMC 107.2.4 & IMC 506.3.2.5) ELECTRIC UNIT HEATER Mark(s) Manufacturer / Model No. DESCRIPTION ELECTRICAL Control REMARKS KW VOLT & PHASE BTU EUH-1 QMARK MUH03-41 Fan -forced wall heater 3 208/3 10,239 Intergral T-Stat, set at 50°F High limit safety, surface mount on wall RADIANT HEATER SCHEDULE HEATING ELECTRIC Mark(s) Manufacturer / Model AREA SERVED VENT INPUT OUTPUT VOLT & WATTS Control CONNECTION (MBH) (MBH) PHASE IRH-1-7 SCHWANK 2313 OR EQUAL Warehouse VERIFY 50 50 115v / 1 ph 40 2-stage Thermostat NOTES: 1. Support Units from structure with threaded rod hangers and painted unitstrut. Units shall have thermal overload protection, finger proof fan guard. 2. Units shall have single -stage gas control, with intermittent pilot ignition. 3. Thermostat shall be installed on insulated sub -base. HOOD SCHEDULE Mark(s) Manufacturer / Model No. TYPE LENGTH CFM FIRE SYS H-1 CAPTIVE AIRE 6030 ND-2-ACPSP-F I 6'-0" 1200 ANSUL R102 H-2 CAPTIVE AIRE 5430 ND-2-ACPSP-F I 10'-0" 2750 ANSUL R102 H-3 CAPTIVE AIRE 5430 ND-2-ACPSP-F I 12'-0" 2400 ANSUL R102 H-4 CAPTIVE AIRE 4230 VHB-G II 6'-0" 900 H-5 CAPTIVE AIRE 4230 VHB-G II 4'-0" 600 NOTES: MAKE-UP AIR UNIT SCHEDULE Mark(s) Manufacturer / Model No. DIRECT FIRED HEATING SUPPLY FAN ELECTRICAL VOLTAGE & PHASE SIZE Input MBH (SL) Output MBH (SL) CFM ESP FAN (HP) LENGTH (IN) WIDTH (IN) HEIGHT (IN) WEIGHT (LBS) MUA-1 CaptiveAireA3-D.750-G18 313 288 4,930 0.85 5.00 208/3 138.875 41.375 43.375 1,029 NOTES: 1. Install Evaporative Cooler Section and provide automatic drain and fill system. 2. Interlock KEF-1 to MUA-1 3. Make-up Air unit shall be provided with factory supplied unit disconnect with unit. 4. Verify all information and requiremetns with the CaptiveAire Drawigns. DIFFUSER, REGISTER & GRILLE SCHEDULE Mark(s) Manufacturer / Model No. DESCRIPTION CONSTRUCTION NOM. CFM SIZE MOUNTING REMARKS EC Titus 3FL CEILING EXHAUST REGISTER ALUMINUM SEE PLANS SEE PLANS SURFACE ES Titus 3FL WALL EXHAUST REGISTER ALUMINUM SEE PLANS SEE PLANS SURFACE RC Titus 50F EGGCRATE CEILING RETURN ALUMINUM SEE PLANS SEE PLANS T-BAR/SURFACE RS Titus 50F EGGCRATE SIDEWALL RETURN ALUMINUM SEE PLANS SEE PLANS SURFACE SC Titus TDC-AA CEILING SUPPLY ALUMINUM SEE PLANS SEE PLANS SURFACE SCL Titus PAS -AA PERFORATED SUPPLY ALUMINUM SEE PLANS SEE PLANS T-BAR/SURFACE SR Titus TMR-AA ROUND DIFFUSER ALUMINUM SEE PLANS SEE PLANS SURFACE EXHAUST FAN SCHEDULE MARK(S) MANUFACTURER/MODEL LOCATION SERVING CFM ESP in MOTOR Damper Type Fan Control ROOF OPENING in x in WEIGHT lbs. NOTES lbs. Watts or HP Voltage & Phase RPM KEF-1 Captive Aire DU5OHFA Roof Cook Line 1,200 0.8 0.5 208/3 1221 Backdraft Interlock w/ MUA 17.5X1.5 64 1, 2, 4, 6 KEF-2 Captive Aire CASRE18DD Roof Cook Line 2,750 1 2 208/3 972 Backdraft Interlock w/ MUA 24X24 228 1, 2, 4, 6 KEF-3 Captive Aire DU180HFA Roof Cook Line 2,400 1.3 1.5 208/3 1278 Backdraft Interlock w/ MUA 24X24 107 1, 2, 4, 6 KEF-4 Captive Aire DU33HFA Roof Dish Machine 900 0.5 1/3 115/1 1490 Backdraft A 17.5X17.5 51 1, 2, 4, 6 KEF-5 Captive Aire DU33HFA Roof Dish Machine 600 0.5 1/3 115/1 1222 Backdraft A 17.5X17.5 51 1, 2, 4, 6 EF-6 Captive Aire DR3OHFA Roof Restroom 750 0.5 1/4 115/1 1425 Backdraft C Verify Verify 1, 2, 4, 6 EF-7 Greenheck - SPA-100 Mop Sink Mop Sink 100 0.25 48 115/1 900 Backdraft A 8"dia thru roof 24 1 NOTES: 1. Intergral gravity backdraft damper 2. Ducted from fan outlet to roof 3. SMACNA approved roof cap 4. Ducted from fan outlet to wall 5. Wall exhaust louver, see plans for size 6. 1/4" galv. mesh birdscreen 6. 12" Manufacturer's roof curb 7. 18" Manufacturer's ventilated roof curb FAN CONTROL: A. Separate wall switch B. Switch on with lights C. 24/7 time clock to operate during occupied times D. Continuous operation E. Interlock with equipment (Marks shown) ROOFTOP HEAT PUMP SCHEDULE NOM. COOLING AMB. EAT HEATING SUPPLY FAN ELECTRICAL SIZE Mark(s) Manufacturer/Model No. TONS EER AIR DB WB HEAT ADD. ELEC. SUPPLY VOLTAGE LENGTH WIDTH HEIGHT WEIGHT Sens Total TEMP °F °F BTU KW CFM ESP FAN (HP) & PHASE MCA MOCP (IN) (IN) (IN) (LBS) RTU-1 Carrier 50TCQD14A1A5-6W0G0 12.5 10.6 119.47 136.3 95 77.8 62.5 96 31 5000 0.5 1.9 208/3 194 200 115.875 63.375 57.375 1793 RTU-2 Carrier 50TCQD14A1A5-6W0G1 12.5 10.6 119.47 136.3 95 77.8 62.5 96 31 5000 0.5 1.9 208/4 194 200 115.875 63.375 57.375 1794 RTU-3 Carrier 50TCQD14A1A5-6W0G2 12.5 10.6 119.47 136.3 95 77.8 62.5 96 31 5000 0.5 1.9 208/5 194 200 115.875 63.375 57.375 1795 RTU-4 Carrier 50TCQD14A1A5-6W0G3 12.5 10.6 119.47 136.3 95 77.8 62.5 96 31 5000 0.5 1.9 208/6 194 200 115.875 63.375 57.375 1796 NOTES: 1. Provide Duct mounted smoke detectors in return duct per code, when unit supplies equal or greater than 2000 CFM. REVIEWED FOR ODE COMPLIANCE 2. Provide 14" in. high manufacturer's roof curb, flash and seal to roof. •' •� RECEIVED ` APPROVED CITY OF TUKWILA 3. Provide 100% enthalpy controlled economizer, with integral barometric relief set to minimum outside air requirements as shown on Ventilation Schedule. 1 8 2016 , . FEB© tU 4. Provide Honeywell T-7300 programmable thermostat with locking cover. FEB 012016 5. Provide louvered hail guards on all units. C[fy of PERMIT CENTER `i AM VENTILATION SCHEDULE (PER IMC, TABLE 403.3) ROOM Rp Ra OUTSIDE AIR OUTSIDE AIR %OSA OF MIN SUPPLY OCCUPANCY AREA PEOPLE ZONE PERSONS TOTAL ZONE PER SQ. FT. REQUIRED SUPPLYING RTU REQUIRED SUPPLY ROOM NAME(S) CLASSIFICATION (SF) AIRFLOW AIRFLOW PER 1000 SF PERSONS Ez PER 2012 IMC* (CFM) (CFM) (CFM) PROVIDED OFFICE AREA OFFICE 57 5 0.06 5 1 0.8 0.11 6 30.0% 20 VESTIBULE CORRIDOR 108 0 0.06 0 0 0.8 0.08 8 30.0% 27 RESTROOM CORRIDOR CORRIDOR 119 0 0.06 0 0 0.8 0.08 9 30.0% 30 DINING ROOMS DINING 4190 7.5 0.18 70 294 0.8 0.88 3,692 30.0% 12308 14670 KITCHEN WARE WASH/COOK 1547 0 0 0 0 0.8 0.00 0 30.0% . N/A fl I A ,. DQSIONP,AR,AML I QRS. LLC 6373 SILVER STREAM LN fRISCO. TX 75034 P1-I: 214.784.5014 Pk 303.223.9104 DESIGNP,ARAMQTQRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80107 Phone: 303.646.1860 Fax: 303.646.5623 START DATE • 17920 SOUTHCENTER PKWY CO co T I- 08252015 PROJECT NO • DRAWN BY • CHECKED BY• ISSUED/REVISED • • DATE P6STT 11.182015 QWNER REVS/BLDG COSSOBVT8 01202018 EXPIRES: 11/15/2017 01/25J2016 MECHANICAL SCHEDULES * OUTSIDE AIR PER SQ. FT. CALCULATED BY THE USE OF EQUATION 4-1 AND EQUATION 4-2 OF IMC. NOTES: GOPYRIoin -nts SHEET METAL STRAPS EQUALLY SPACED PER ARCHITECTURAL DRAWINGS ROUND SPIRAL DUCT SEE PLAN 1 GRINNEL #290 GALV. EYELET NUT & 3/8" 0 ALL THREAD MOUNTED WITH EYELET & BOLT ATTACHED TO PURLINS ABOVE WITH GALV. SIDE BEAM BRACKETS. CONTRACTOR SHALL PROVIDE DUCT HANGERS AND CONNECTION TO STRUCTURE AS PART OF MECHANICAL SUBMITTAL. 23° SPIRAL DUCT SUPPLY REGISTER WITH SCOOP DAMPER SPIRAL DUCT DETAIL MO.1 SCALE: NTS NOTE: INSTALLATION SHALL CONFORM TO U.L. 762. GREASE TROUGH ANCHOR FAN TO CURB WITH CADMIUM PLATED LAG SCREWS (MIN. 2 PER SIDE) ROOF CURB TO BE SELECTED TO MATCH FAN ROOF 1 1/2" 1 3 IN. (76 MM) MIN. PERIMETER OVERLAP ON OUTSIDE LAYER © 0 WANZIONJfIJrlWAVI 0 BUTT-JOINT/3"OVERLAP 0 0 \ \\ \\ / /././,/i/% /./, /i/i ',\\.,\\,\\,"\\ .\ 21" TYP. 1 1/2" 0 2 x 2 x 1/8 IN. MIN. ANGLE 0 1/2 IN. (13 MM) MIN. CARBON OR STAINLESS STEEL BANDING - 0.015 IN. MIN. THICKNESS TYPICAL - PLACED AT 10-1/2 IN. SPACING AND CENTERED OVER OVERLAPS 1 1/2" 0 /,1/(/i'//'//'/i'/i i(/,,(/,� 12" 24" BUTT-JOINT/COLLAR 0 1 1/2" 1 I 1 1/2" \\ ,\ 0 TELESCOPE WRAP OPTION BUTT JOINT OPTION L 0 0 \ 3" t 111/2" ,\\\ 21" TYP. CHECKERBOARD WRAP OPTION SINGLE LAYER OR OUTSIDE LAYER INSTALLATION OPTIONS 2 GREASE DUCT INSULATION DETAIL MO.1 ROOF MOUNTED UPBLAST CENTRIFUGAL EXHAUST FAN HINGED ACCESS WITH SAFETY CABLE VENTED CURB EXTENSION 40" MIN Lk— GREASE DUCT ENCLOSURE SEE ARCH'L DWGS. OR U.L. LISTED FIREWALL INSULATION (SEE PLANS). EXHAUST DUCT ROOF MOUNTED GREASE EXHAUST FAN DETAIL SCALE: NTS CONDENSER FAN DISCHARGE DISCONNECT SWITCH (SEE ELECTRICAL DWGS. UNLESS FACTORY MOUNTED.) PREFABRICATED ROOF CURB POWER WIRING (SEE ELECTRICAL) 5 OUTDOOR AIR INTAKE HOOD 0 BAROMETRIC RELIEF HOOD RETURN AIR DUET SMOKE DETECTOR WIRED INTO F/A SYSTEM AS REQUIRED. THERMOSTAT WIRING SUPPLY AIR DUCT ROOF DECK SCALE: NTS TERMINATE CONDENSATE DRAIN AS NOTED ON PLANS. DIAGRAMMATIC ROOFTOP AIR UNIT MOUNTING MO.1 SCALE: NTS CONNECT FLEX DUCT ENDS TO SHEET METAL DUCT AND DIFFUSER NECK WITH NYLON TIES AND MASTIC OR UL APPROVED PRESSURE TAPE. INTERIOR LINER AND EXTERIOR INSULATION OF FLEX DUCT TO BE TIED INDIVIDUALLY. INSTALL USING TENSIONING TOOL AS PER MANUFACTURER'S RECOMMENDATIONS. ROUND SHEET METAL DUCT DIAMETER AS INDICATED ON PLANS. BRANCH DUCT J NOTES: DUCT WRAP MUST HAVE A LISTED ICC-ES-REPORT. REFER TO http://www.icc-es.org/reports/index.cfm?list=list FOR A COMPLETE LIST OF ICC-ES-REPORTS. IF THERMAL CERAMICS, INC. FIREMASTER FASTWRAP XL IS USED THE PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH ESR-2213 WHICH IS AVAILABLE FOR DOWNLOAD AT THE LINK LISTED ABOVE. SPECIAL INSPECTION REQUIRED FOR FIRE WRAP ON TYPE I EXHAUST HOOD DUCT. INSTALLATION MUST BE OBSERVED BY CERTIFIED INSPECTOR FOR TYPE OF FIRE WRAP BEING USED. INSTALLATION INSTRUCTION NOTES: TWO LAYERS OF FIREMASTER FASTWRAP XL BLANKET FOR O GREASE DUCT ENCLOSURES ONE LAYER OF FIREMASTER FASTWRAP XL BLANKET FOR AIR VENTILATION DUCT ENCLOSURES. O STEEL BANDING MINIMUM 1/2" WIDE BY 0.015" THICK. 0 TIGHT BUTT JOINTS ON INNER LAYER. OMIN. 3" OVERLAP ON PERIMETER AND BETWEEN ADJACENT BLANKET ON OUTSIDE LAYER. 50 MIN. 3/8" DIAMETER HANGER ROD. 6 MIN. 2" X 2" X 1/8" ANGLE FOR GREASE DUCT ENCLOSURES. 6 MIN. 1-1/2" X 1-1/2" X 1/8" ANGLE OR SMACNA EQUIVALENT FOR AIR VENTILATION DUCT ENCLOSURES. O7 OPTIONAL 6" FIREMASTER FASTWRAP XL COLLAR A NYLON TIES INTERIOR LINER PREINSULATED FLEXIBLE DUCTWORK. SEE SPECIFICATIONS. FLEX DUCT. PROVIDE SUPPORT PER SMACNA STANDARDS. INSTALL FREE OF KINKS & SAGS. CONICAL SPIN -IN TYPE FITTING WITH DAMPER & SCOOP SUPPLY GRILLE SEE ARCH. PLANS FOR TYPE FLEXIBLE DUCT TAKE -OFF DETAIL SCALE: NTS ROOF GREASE DUCT TO FULL FAN INLET SIZE MAKE-UP AIR ROUTED TO MUA FAN MUA DUCT (MVD1 CEILING JUNCTION BOX FOR LIGHTS HOOD MOUNTED CONTROLS BY HOOD VENDOR TYPE 1 HOOD SHALL AUTOMATICALLY ACTIVATE WHEN COOKING OPERATIONS OCCURS. GREASE DUCT SHALL HAVE A SMOOTH TRANSITION WITH CLEANOUTS PER NFPA 96. 1ST FLOOR MIN. 48" ABOVE COOKING SURFACE IF HOOD SECTION DETAIL GREASE EXHAUST FAN UL. LISTED MANUFACTURER'S GREASE DUCT KITCHEN HOOD (BY OTHERS) MO.1 SCALE: NTS REAVdED FOR CODE COMPLIANCE APPROVED FEB 18 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 012016 DESIGNPARAMU I Q2S, LLC 6373 SILVER STRQAM LN �RISCO. TX 75034 PI-1: 214.784.5014 pX: 303.223.9104 DESIGNPARAMQTTRS.COM John Tinsley, P.E. 38140 Fawn Meadows Tr. Elizabeth, Colorado 80107 Phone: 303.646.1860 Fax: 303.646.5623 W z 17920 SOUTHCENTER PKWY TUKWILA, WA 98188 START DATE • OB252015 PROJECT NO • TwP01 DRAWN BY • CHECKED BY• ISSUED/REVISED • • DATE PERI I 11.132015 CYWER REVSfBLDO COMMIS 01202016 EXPIRES: 11/15/2017 01/25r2016 MECHANICAL DETAILS RMIT CENTER cornuairronottne