Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D15-0286 - 646 BUILDING / PHAM HOA - ADD WALLS
D15-0286 City of Tukwila • r Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone:206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 0005800037 Address: 646 STRANDER BLVD Project Name: HOA PHAM Owner: Name: BC PARTNERS LLC Address: PO BOX 997 C/O MK PROPERTY SERVICES LLC, SNOQUALMIE, WA, 98065 Contact Person: Name: HOA PHAM Address: 23610 51 AVE S , KENT, WA, 98032 Contractor: Name: ALPHA CONSTRUCTION LLC Address: PO BOX 1162, WOODINVILLE, WA, 98072 License No: ALPHACL925MQ Lender: Name: HOA PHAM Address: 23610 51 AVE S , KENT, WA, 98032 DESCRIPTION OF WORK: TI Add Wall Permit Number: c D15-0286 Issue Date: IT, I t� Permit Expires 0 5/9/2016 Phone: (512) 796-4103 Phone: (425) 877-7123 Expiration Date: 9/9/2016 BUILDING WALLS TO SEPARATE ROOMS. 2 ROOMS 10 X 14,14 X 15 Project Valuation: $15,000.00 Fees Collected: $657.82 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Occupancy per IBC: B Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Volumes: Cut: 0 Fill: 0 Number: 0 Storm Drainage: Street Use: Water Main Extension: Water Meter: No Permit Center Authorized Signature: Date: f� ` ✓ I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. ;�9, U Signature: I_ P-2— Date: &;005— Print Name: (-40 11A e/4IA-W This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: 'BUILDING PERMIT CONDITIONS' 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 5: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 6: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 16: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 13: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 17: Maintain fire extinguisher coverage throughout. 18: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 19: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 20: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 22: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 26: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 24: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 23: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 27: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2437. 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 25: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 32: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 33: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL" 1400 FIRE FINAL 0409 FRAMING N CITY OF TUKPP AA Community Development Department • Public Works Department • Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 bM://www.TukwilaWA.P,ov SITE LOCATION Building Permit No. Project No. Date Application Accepted: Date Application Expires: C� 1101 f I (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" gQKing Co Assessor's Tax No.: Site Address: �klo 5�ranc/' ��yd,! �U�II1�At W� (D��� Suite Number: Floor: .1 Tenant Name: HOA WOK New Tenant: Rr—yes [I.. No PROPERTY OWNER �" Name: !J ellna A 5cviceC LA4k �(/ (� v-f'f1/Itt6 Address: [City, t mie State: Zip: AyO�5� u CONTACT PERSON — person receiving all project communication Name: 00)�" PWAW, Address: yw 0 51 s { City: otlf- State: l) 4- Zip:gp1a Phone: 6� (a - �% _ �� Fax: Email: 74 , ,41 AWk 0' OWl U GENERAL CONTRACTOR INFORMATION Company Name: Al Address: 17d - �01 T City: /J W I 10V I �� State: A Zip: fW 02 Phone: ,/8��1 _ a� Fax.. Contr Reg No.: K ( hu I p1 0 t�ut Exp Date: Tukwila Business License lNo.: ARCHITECT OF RECORD Company Name: Al r4l irusiruch'Ovi 1-LL Architect Name: Dino Address: P. oD I City: 00 ; State: wA Zivoo o� . i/ Phone: j p S 8 3 Fax: %% Email: Af ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: � Address: -No to 6-1 9''r ,e City: PAA � State: Zip: :Z- H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 1 of 4 VJ BUILDING PERMIT INFORMATIC 206-431-3670 Valuation of Project (contractor's bid price): $ dJ1!iJv(1 �UU-/ Existing Building Valuation: $ Describe the scope of work (please provide detailed information): hikild j/_�,()�j` 6 -ho :e iB0Y11 h . f0�in�j. IDXIN IgYI5`. Will there be new rack storage? ❑ .... Yes �No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC I" Floor 35C� I l S �j-$us•�e 5 2"d Floor P Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq 8): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ ....... Yes �...... No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ..... Sprinklers Automatic Fire Alarm El ....... None El ....... Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ .......Yes Ate...... No If `yes', attach list of materials and storage locations on a separate 8-112" x I " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ .......On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 11. Page 2 of 4 O PUBLIC WORKS PERMIT INFtL RATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ... Water District #125 El ... Highline El ... Renton ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ ...Valley View ❑... Renton ❑... Seattle ❑ .. Sewer Use Certificate ❑ ...Sewer Availability Provided Septic System: ❑ On -site Septic System — For on -site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which an ❑ .. Civil Plans (Maximum Paper Size — 22" x 34" ❑ .. Technical Information Report (Storm Drainage) El ... Geotechnical Report ❑ .. Traffic Impact Analysis ❑ .. Bond ❑... Insurance ❑... Easement(s) El ... Maintenance Agreement(s) ❑ .. Hold Harmless — (SAO) El.. Hold Harmless — (ROW) Proposed Activities (mark boxes that apalv): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours El ... Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑... Right-of-way Use — Potential Disturbance ❑ .. Con struction/Excavation/Fi11 - Right-of-way ❑ Non Right-of-way ❑ ❑ .. Total Cut cubic yards ❑ .. Total Fill cubic yards ❑ .. Sanitary Side Sewer ❑ .. Cap or Remove Utilities ❑ .. Frontage Improvements ❑ .. Traffic Control ❑ .. Backflow Prevention - Fire Protection Irrigation Domestic Water El ... Work in Flood Zone ❑... Storm Drainage ❑... Abandon Septic Tank ❑... Curb Cut El ... Pavement Cut ... Looped Looped Fire Line El ... Grease Interceptor ❑ ... Channelization ❑ ... Trench Excavation El ... Utility Undergrounding ❑ .. Permanent Water Meter Size (1) WO # (2) WO # (3) ❑ .. Temporary Water Meter Size (1) WO # (2) WO # (3) ❑ .. Water Only Meter Size........... WO # El.. Deduct Water Meter Size_ ❑ .. Sewer Main Extension............ Public ❑ Private ❑ ❑ .. Water Main Extension............ Public ❑ Private ❑ FINANCE INFORMATION Fire Line Size at Property Line ❑ .. Water ❑ .. Sewer Monthly Service Billing to: Mailing Water Meter Refund/Billine: Mailing Number of Public Fire Hydrant(s) ❑ .. Sewage Treatment Day Telephone: City Day Telephone: WO # WO# State Zip City State Zip H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 3 of 4 1 PERMIT APPLICATION NOTES — . Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ONNVR OR AUTHORIOD AGENT: Print Name: tw JTo A t' /f►'1K Mailing Address: O w o 571 t' Ayt 13' Date: Day Telephone: n State Zip H:Wpplications\Forms-Applications On Line\2012 ApplicationsTermit Application Revised - 2-7-12.docx Revised: February 2012 Page 4 of 4 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $408.02 D15-0286 Address: 646 STRANDER BLVD Apn: 0005800037 $408.02 DEVELOPMENT $388.80 PERMIT FEE R000.322.100.00.00 0.00 $384.30 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $19.22 TECHNOLOGY FEE • R6811 R000.322.900.04.00 0.00 $19.22 $408.02 Date Paid: Monday, December 07, 2015 Paid By: HOA PHAM Pay Method: CREDIT CARD 065454 Printed: Monday, December 07, 2015 1:46 PM 1 of 1 � SYSTEMS Date Paid: Monday, November 09, 2015 Paid By: HOA PHAM Pay Method: CREDIT CARD 087260 Printed: Monday, November 09, 2015 12:36 PM 1 of 1 ... _. SY57EM5 INSPECTION RE Retain a copy with INSPECTION NO. V" -ORD y� erm. it ���UO��� p PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: AQ-- �% / Type of Inspe 'on:. P I40 1 Addres Date Called: Special Instructions: Date Wanted: / a, p.m. Requester: Phone No: Approved per applicable codes. E Corrections required prior to approval. COMMENTS: � — Inspector: , � Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (2.06) 431-3670 Permit inspection Request Line (206) 438-9350 Project: 101 HOType of Insgction `/�A Addsess; 5/ �`� D e Called: Special Instructions: Date Wanted: Requester,J- Phon��o: Approved per applicable codes. LJ Corrections required prior to approval, u paid at 6300 Southcenter Blvd., Suite 100. Call. to schedule reinspection. INSPECTION RECORD Retain a copywith permit 196 a0� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 SotAhcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: / / Type of Inspe on: Addr s pate Called: Special Instructions: Date Wanted: m. P.m. Requester: Phone No: Approved per applicable codes. E ILorrections required prior to approval. u paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. v( INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWVILA, BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project:[ % %©� ��'tA'A Type of Inspection* De Called: Special Instructions: Est' Date Wanted: 9r�� p.m. Requester: ��`-- Phone No: .Approved per applicable codes. LJ Corrections required prior to approval. Inspector: � Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Catt to schedute reinspection. INSPECTION RECORD LLJ D2-1 Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukw Ia. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project_ Type of Insp 'on: Address: T1 z z -I- to Called: Date Wanted: Special Instructions: Requester: �rl�5 Phone_N,o: 12, -�9� - y� c�3 Approved per applicable codes. EL--yorrections required prior to approval. COMMENTS: env A� 7D�o 40 Qe-1-,Q—eFk- - L".e' F-1 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. CaR to schedule rpinsppction. INSPECTION RECORD 5- -- CO-64 Retain a copy with permit S a I o INSPECTION NUMBER PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: IJOA 10HAM Type of Inspection: 5;6D 5e (!Oj-PI � , r- C• Address: Gyb S��Fl�� sf j Suite #: Contact Persoh: Special Instructions: Phone No.. V-1-Approved per applicable codes. ❑ Corrections required prior to approval. COMMENTS: v Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: �,/�/� c-Z_ Date: //7 � Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. tsming Aaaress Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 North IpwmR Vicinity Map showing location of site ft ',E --t' - "^^"'•. � � DUiLLlIiVV uIVIJli1t } Plan review approval is cubjed to gore and omissi NOTE: Revis?�� wits require a now pin szr t Approval of construction dommants does not authorize C!r.1 rrly '�� ue t�ddi�or�t Ran rsv:4w f36S the violation of any adopted a of approved Field Fppy and conditions is acknowledged: s : 450 ft RZECE �r&c CITY OF TU"I"% N]LA Date: 1911115 SERA!IATE PERMIT RFOUIRED FOR: NOV 0 9 2015 City of Tukvjj1a BUILDING DIVISION Legal Descriptio ABBREVIATED: LOT 1, SP 84-31-SS, REC 8501020748 O chaniid 9 Electrical Plumbing ,UGas Piping PERMIT CENTER PARCEL A: C 4 c+ Tu%villa DIVISION ION LOT 10F CITY OF TUKWILA SHORT PLAT NO 84-31-SS, ACCORDING TO SHORT PLAT RECORDED JANUARY 31sT, 1985 UNDER RECORDING NO 8501030748, IN KING COUNTY, WASHINGTON Total Area Floor Plan front door Working area (Fre ipg�aevU-*qlls wx $' from corners SIMI_1►19 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 19 2915 City of Tukwila BUILDING DIVISION CE i Vz J CiT-.f OF Tt)KAILA NOV 0.9 2015 PERMIT CENTER Construction Details 1) Masking, preparation and material ordering 2) Framing up two rooms—14'x10', 14'x15' a. U-Shape 2x4s will be inserted into outside existing walls with wood studs b. New walls connection with 3 inch screws c. Base of new walls will be anchored down with strong ANCHOR BOLTS Reistance Force Plywood Shear Panel z?c woad sf�e -2 f 'o P-01, 1-or f �a l �rpt r Earthquake Horizontal Force c- Anchor Bolt compresses P,-r wood to resist sliding Vex 4s1I1 Anchor Bolt ambedded in concrete foundation d. No insulations for new interior walls 3) Drywall, mud, texture (orange peel), primer, paint (wall only) 4) New ceramic tile in the bathroom 5) New laminate flooring 6) New base trim installation 7) Installing Seismic bracing attaching new walls to existing ceiling �) W®od 14'a1- `L �Qj/- 1bG Se-r-4yat-i 2�3o5 (Details on next two pages) REVIEWED FOR CODE COMPLIANCE APPROVED NOV 19 2015 City of Tukwila BUILDING DIVISION =., - ;r!- CITY OF T!j?.WiLA NOV 0 9 2015 PERMIT CENTER Attachment of Seismic Bracing to Wooden Ceiling Beams Above Ceiling Tiles Q 511 I;" diameter lag bolt attached, to Geittng structure— -- !tingle brad 1 11r x 1 112" x 118" at 6' on center Gar" maximum -511 V diameter bo dt 511 F duameter bolt or three (1) #12 sheet Metal or wood screws Partial height partition RA2 - SEISMIC BRACING OF NON-STRUCTURAL PARTITIONS AND ROOM DIVIDERS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 19 2015 City of Tukwila BUILDING DIVISION CI'6 v OF TUKWILA NOV 0 9 2015 PERMIT CENTER HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D15-286 DATE: 11/09/15 PROJECT NAME: HOA PRAM SITE ADDRESS: 646 STRANDER BLVD 1 Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division ® Fire Prevention �j Planning Division b Vk NIA I H /(S- Public Works N Structural ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: DATE: 11/10/15 Not Applicable ❑ Structural Review Required ❑ (no approvalireview required) REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/08/15 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 ALPHA CONSTRUCTION LLC Page 1 of 2 Home lnido en Espanol Contact Safety (D Washington State Department of Labor & Industries ALPHA CONSTRUCTION LLC Owner or tradesperson Principals HASANAGIC, IZUDIN, PARTNER/MEMBER Doing business as ALPHA CONSTRUCTION LLC WA UBI No. 602 709 945 License Search L&I A-Z Index Help Dap Secure L&I Claims & Insurance Workplace Rights Trades & Licensing P.O. Box 1162 WOODINVILLE, WA 98072 425-877-7123 KING County Business type Limited Liability Company Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....................................................................... . Meets current requirements. License specialties GENERAL License no. ALPHACL925MQ Effective — expiration 07/18/2008— 09/09/2016 Bond ...............1. Wesco Insurance Co $12,000.00 Bond account no. 46wb029512 Received by L&I Effective date 06/24/2013 06121 /2013 Expiration date Until Canceled Bond history Insurance Ohio Security Ins Co $1,000,000.00 Policy no. BKS53742862 Received by L&I Effective date 05/15/2015 05/21/2011 Expiration date 05/21/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the 1.bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations ............ No license violations during the previous 6 year period. htti)s:Hsecure.lni.wa.gov/verify/Detail.aspx?UBI=602709945&LIC=ALPHACL925MQ&SAW= 12/03/2015