Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D16-0038 - FOSTER HIGH SCHOOL - FIRE DOOR AND PANEL
FOSTER HIGH SCHOOL 4242 S 144TH ST D16-0038 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 1523049108 4242 S 144TH ST Project Name: FOSTER HIGH SCHOOL DEVELOPMENT PERMIT Permit Number: Issue Date: Permit Expires On: D16-0038 6/28/2016 12/25/2016 Owner: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 Contact Person: Name: JAMES HILL Address: Contractor: Name: Address: License No: Lender: Name: Address: 828 7TH AVE SE , OLYMPIA, WA, 98501 FORMA CONSTRUCTION COMPANY PO BOX 11489, OLYMPIA, WA, 98508- 1489 FORMACC878OR TUKWILA SCHOOL DISTRICT 4640 S 144TH ST, TUKWILA, WA, 98168 Phone: (360) 352-8883 Phone: (360) 754-5788 Expiration Date: 9/19/2017 DESCRIPTION OF WORK: REPLACE EXISTING DROP DOWN FIRE DOOR AND CONNECT TO FIRE PANEL Project Valuation: $26,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $1,051.20 Occupancy per IBC: E Water District: 125 Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: .�� 1 Date: t, 0-1 co I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. le,, �'/ Signature: Print Name: LiCatzdeiJil Date: 6` Zg l 1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: Fire door to close upon activation of any fire alarm. Ensure a smoke detector installed within 5 ft. of opening on both sides. 8: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 9: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 7: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL 0502 LATH & GYPSUM CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.TukwilaWA.00v Building Permit No. MO.00 7-1(3 Project No. Date Application Accepted: 'v ! I (l Date Application Expires: 01 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 1523049108 Site Address: 4242 S 144th Street, Tukwila, WA 98168 Suite Number: Floor: Tenant Name: Foster High School PROPERTY OWNER Name: James Hill Name: Tukwila School District Address: 828 7th Ave SE Address: 4640 S 144th Street --,.,. City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: James Hill Address: 6006 3rd Ave S Address: 828 7th Ave SE Phone: (206) 832-8181 Fax: City: Olympia State: WA Zip: 98501 Phone: (360) 352-8883 Fax: Phone: (360) 352-8883 Fax: Email: jameshill@kmbdesign.com Email: jameshill@kmbdesign.com GENERAL CONTRACTOR INFORMATION Company Name: MCKinstry Address: 6006 3rd Ave S City: Seattle State: WA Zip: 98134 Phone: (206) 832-8181 Fax: Contr Reg No.: MCKINEL974CL Exp Date: 02/13/2017 Tukwila Business License No.: BUS -0994786 H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised- 8-9-I l.docx Revised: August 2011 bh New Tenant: El Yes LZ ..No ARCHITECT OF RECORD Company Name: KMB Design Groups, Inc Architect Name: James Hill Company Name: NA Address: 828 7th Ave SE City: City: ..1.vaw I' City: Olympia State: WA Zip: 98501 Phone: (360) 352-8883 Fax: Address: Email: jameshill@kmbdesign.com ENGINEER OF RECORD Name: Li It of Cix064%.4q, law TIG-. S . Y Address: t.0,40 Company Name: NA 1 --- City: City: ..1.vaw I' Engineer Name: - Zip: Gl 21(,,,g Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Li It of Cix064%.4q, law TIG-. S . Y Address: t.0,40 5 t4 4_4, 1 --- City: City: ..1.vaw I' State: - Zip: Gl 21(,,,g Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 26,000 Existing Building Valuation: $ Describe the scope of work (please provide detai led information): K ( 3C d to o OLOultl.) LK£ ctQO✓L . tC CO . Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes Z No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes Z No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised- 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l' Floor 65,677 0 0 0 II A's and E-1 2"d Floor 695 0 0 0 II A-2 3rd Floor Floors thni Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes Z No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: Sprinklers Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes Z No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11 "paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised- 8-9-1 I.docx Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Replace the existing fire door between the corridor and cafeteria. Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ..• .Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ..• .Tukwila ❑ ...Sewer Use Certificate El ...Valley View ❑ ...Sewer Availability Provided ❑ .. Highline ❑ .. Renton ❑ .. Renton ❑ .. Seattle Septic System: ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) ❑ .. Maintenance Agreement(s) ❑ ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way ❑ ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage ❑ ...Sanitary Side Sewer ❑ .. Abandon Septic Tank ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ ...Frontage Improvements ❑ .. Pavement Cut ❑ ...Traffic Control ❑ .. Looped Fire Line ❑ ...Backflow Prevention - Fire Protection " Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public ❑ Private ❑ ❑ ...Water Main Extension Public ❑ Private ❑ ❑ .. Grease Interceptor ❑ .. Channelization ❑ .. Trench Excavation ❑ .. Utility Undergrounding WO # ❑ ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name- Day Telephone: Mailing Address: Water Meter Refund/Billinc: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: R OR AUTHORIZED AGENT: Print N."e --14,,,-ti 5 t• -Fc Mailing Address: gig 71 SF H:\Applications\Forna-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Date: I ! / l 0/15— Day /15— Day Telephone: 36 0. 3 88 $ T OLTr'1? IA QIpSC) City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $1,051.20 D16-0038 Address: 4242 S 144TH ST Apn: 1523049108 $1,051.20 DEVELOPMENT $1,020.41 PERMIT FEE R000.322.100.00.00 0.00 $615.70 PLAN CHECK FEE R000.345.830.00.00 0.00 $400.21 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $30.79 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R7670 R000.322.900.04.00 0.00 $30.79 $1,051.20 Date Paid: Thursday, February 11, 2016 Paid By: LILIANA CARDENAS Pay Method: CREDIT CARD 031174 Printed: Thursday, February 11, 2016 10:34 AM 1 of 1 CPSYSTEMS INSPECTION RECORD Retain a copy with permit NS' CTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Net-©oZ Proje frOS7E-4.2 1-1I6I4 gHCOL. Type of Inspection: ISO ic.b, AIS- Yrs/ L Address: 421425 )44L/PI C Date Called: Special Instructions: Date Want�l: I �� aCio .f 0 : Requester. Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: ,,////6 /6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Inspector: INSCTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr do r62 6i4 Sc&VL Type Type of Inspe n• G Iio64 Rvxvt Address: g2Q2 S figin4 S7- Date Called: Instructions: 2)b 2.-A-msfe Date Wanted: 7Special � �� Requester: Phone No: Approved per applicable codes. Ll Corrections required prior to approval. COMMENTS: Date:? z0)/, n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. kAN INSPECTION NO. 1 INSPECTION RECORD Retain a copy with permit U4 R °° 1° PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila, WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje r� -6ee /4/644S(M6 1-- Type of Inspection: Mn+ 61PS w Address: 412,112 ilign't Sr - Date Called: Special Instructions: Date Wante :j 72o//‘ a.m. Requeste : j Phone No: J Approved per applicable codes. D Corrections required prior to approval. COMMENTS: LN‘N Inspector:A Date: AM REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FORMA CONSTRUCTION SEATTLE & OLYMPIA WASHINGTON P 206.6260256 WWW.FORMACC.COM TO Janna Peters/Jeff Feeney KMB Architects 906 Columbia St., Suite 400 Olympia, WA 98501 WE ARE SENDING YOU : Attached ❑ Shop Drawings LI Copy of letter ❑ Under separate cover via ❑ Prints `-I Change order LETTER OF SUBMITTAL TRANSMITTAL & RESPONSE ST. CONT. REG. N0. FORMACCBTBOR DATE 5131/2016 FORMA JOB NO. 16853 CONTRACT NAME TRANSMITTALB !ARCH JOB NO. Foster High School Fire Door Replacement the following items: [I] Plans [-] Samples LRJ Shop Drawings, Brochure & Color Page nSpecifications Item # SPEC RESPONSE 1 N/A 08 3513.23 Accordian Folder Fire Doors - S :,p Dr "A c• . o. EIVED TUKWILA 08 2016 N/A CODE N/A NIA i R 2 4F N/A 134-2 -CITY NIA NIA -AU • fele NIA DIVISION IT CENTER N/A BUILDING ` _ THESE ARE TRANSMITTED as checked below: Dfli For approval Bethany Carter pRINTEONAM6 ^ For your use '"As requested Project Manager TIT -LE - --- '.1 For review & comment 206-437-6649 PHONEA The Engineer has reviewed the above noted documents and responded as noted above, under 'Response." Key: NE = NO EXCEPTIONS TAKEN MC = MAKE CORRECTIONS NOTED' No resubmittal feeg sired, but correttlons noted are required' SI = SUBMIT SPECIFIED ITEM: Resubmittal required - rejected, see comments below RR = REVISE AND RESUBMIT: Resubmittal required - rejected, see comments below RJ = REJECTED - see comments below COMMENTS AND SIGN•OFF: # (Key to above) COMMENT NOTES: 1. IN EMERGENCY MODE, ACCORDIAN DOOR OPENING TO • BE PROGRAMMED TO A MINIMUM OF 44" CLEAR WIDTH OR. - FULL OPEN. 2. DOOR CLEAR OPENING TO BE 8'-6" WIDE X 9'-0" HIGH. HEIGHT TO MATCH EXISTING OPENING. COPY TO Janna Peters 06.01.2016 PRINTED NAME TITLE See Attached Comments See Mark-Up of Submittal Documents N enclosures are not as noted, kindly notify us at once. CORREC.TION LTR# ■ ▪ i■..u■ ■!■E■■■ ■ 11■111111111■ MOM design groups SUBMITTAL REVIEW O NO EXCEPTIONS TAKEN ACCEPTED AS NOTED ❑ REJECTED / RESUBMIT PHONE 4 u See Other Attachments D14 - 0o3$ Submittal Transmittal Form.xlsx To: FORMA Construction Company P.O. Box 11489 Olympia, WA 98508 USA Attn: Bethany Carter bethanvc@formacc.com a\ insTF AO, o' 7-37 SUBMITTAL PACKAGE Project Name & Scope of Work Project Name: Foster High School Specification Number: 08 35 13.23 Specification Type: " Accordion Folding Fire Doors Won -Door Corporation's Project #: 98185 • !Enclosed is th Quantity 1 1 1 e Following information Description Product Brochure Shop Drawings Color Chart Remarks Please return all reviewed/approved submittal documents to the following address: Won Door Corporation 1865 South 3480 West Salt Lake City, UT 84104 NOTES LOCATION FOLDING PARTITION SCHEDULE I. UNITIZED TRACK BY WON -DOOR 3 NOTE: 4. IN EMERGENCY MODE, ACCORDIAN DOOR 5. OPENING TO BE PROGRAMMED TO A MINIMUM 6. OF 44" CLEAR WIDTH OR FULL OPEN. 7. ,. ;v DOOR NUMBER -csev Op —DOOR CC 1865 SOUTH 3 SALT LAKE CIT TELEPHONE: (81 < cl DOOR MODEL WIDTH AT�HEIGHT TO ii`4/�jb • �' TOP OF TRACK I PLAN DIMENSIONS see mark - following l c `o a . r r • tr.: < UNLESS AN AIR PRESSURE LEVEL IS SPECIFIED, IT IS ASSUMED THAT ANY AIR PRESSURE PLACED ON THESE DOORS WILL NOT EXCEED 0.05" W.C. 11 WEEK LEAD TIME AFTER RECEIPT OF APPROVED COLOR AND GUA t WON -DOOR MINIMUM ' STACK DATE SINGLE W PARTING DESCRIPTION REVISIONS BI PARTING S. + FIRE EXIT HARDWARE `0 Y SWITCH NOTE # FIREGUARD & MOVEABLE FIRE WALL n MOTOR 1:. TYPE —.c �» COLOR A: CLEAR WIDTH FROM FACE OF POCKET TO STRIKER WALL B: POCKET DEPTH C: SUBFLOOR TO TOP OF TRACK D: SUBFLOOR TO BOTTOM OF SOFFIT WALL E: FINISHED FLOOR THICKNESS F: BOTTOM OF SOFFIT WALL TO BOTTOM OF STRUCTURAL ATTACHMENT f,) PAGE 3 Dz z I PLAN VIEW DIMENSION „B., - PAGE C E ria z HEAD DETAIL E3Y: '-2 z C i Cel -5 z 7. 7.n z - ADDRESS LINE/ID K PROJECT NAME: FOSTER HIGH SCHOOL DRAWN BY: JJG • SHEET: I OF: 7 DATE: 5/25/20I6 CHK'DBY: ' 0 O 0 Q1 0 m C O 0 a Oo 0 m `ten gleV1 NOISN1110 ft4 2t° to Qe O X t7 g N z iWEII 5 7/8" t „t/E „0—`I z > a JIQVIH NIV'Id WON -DOOR CORPORATION i FIREGUARD CS PLAN VIEW Z O%) �[ Z:n V CH �C inc›-2 0 v 0 0 0 to 0 0 r u 3._OK FABRICATION HEIGHT FROM TOP OF FIN. FLOOR TO TOP OF TRA 0 C' o' Cl WON-DOOR CORPORATION FIREGUARD CS ELEVATION LI f E m Z T inv irt PRE -FINISHED WHITE TRACK ASSEMBLY BY WON -DOOR 1§ (BOTTOM OF SOFF! f TO BO` I OMS (0F ATTACHMENT (MIN 511, MAX 5-01 <magi mm ,? J r cq mQ c WON -DOOR CORPORATION 10C1Z ITU ')Aon In1cCT FIREGUARD CS 90 HEAD DETAIL F!I gi EPr rE &N = J -4Z�.. kr ON 01/14 20; _so CCo� Z SZl3H4.0 .l@ ONI'7107121 Sr1011NINNO0 Orse p mmwa -"J o �O -c - Z OQ 30 imU-fus N m b li mZ (1)E z0 Al X5 E I> r r 0 0 oZ FLOATING JAMB STOPS BY WON -DOOR. SbISH10 AG VNI b'A Sf1Of1NILNO0 'HOOQ-NOM AH HMI' DNIGfT DNJNadO 2Ida'IO WON -DOOR CORPORATION FIREGUARD CS 90 DETAIL WON -DOOR CORPORATION 40CC CflI ITIJ 1A0n InfCCT FIREGUARD PERSPECTIVE DETAIL 4 fl NI wZ►b"1b' X 8 L \ AC. WIRING TO CONTROL BOX 5.-o" F-1 LJ 'OBIOPI 332I 111 XOR 702LLN00 'oDa,n au rn d.INn Rata MOW '0'a WHITE I YELLOW RED h0 r C m I GREEN BROWN GREY I I I I I I I I I I I COLOR BLACK 10 CONDUCTOR CABLE IN POWER LIMITED JUNCTION BOX. 20 TO 14 GA ACCEPTABLE 1+ WIPER + J Z o N.O. WIPER I WIPER WIPER N.O. n riD D r a m x N d TROUBLE d FUNCTION I 1 g I i ! 3'—O" / F-1 LJ 'OBIOPI 332I 111 XOR 702LLN00 'oDa,n au rn d.INn Rata MOW '0'a WHITE I YELLOW RED h0 r C m I GREEN BROWN GREY PURPLE ORANGE I COLOR BLACK 10 CONDUCTOR CABLE IN POWER LIMITED JUNCTION BOX. 20 TO 14 GA ACCEPTABLE 1+ WIPER + J Z o N.O. WIPER I WIPER WIPER N.O. n riD ALARM INPUT r a m x DOOR STATUS TROUBLE SUPERVISORY FUNCTION I 01-3e1..iz®01z 000 7.0 2o4 M zVy C]C» �yti .. Catsjel (1" o tm2an 3.(14 to ao ij **a CORPORATION 'FIREGUARD ELECTRICAL DIAGRAMI — , 0 _ , } 08 11 73/WON BuyLine 3726 WON -DOOR FireGuard*M The ORIGINAL horizontal sliding accordion fire door. Fire Safety by Design Setting the standard 2 Typical applications 3 Egress applications 4 Non egress applications 5 Listings and approvals 6 Standard features 7 How to specify 8 WON -DOOR CORPORATION Salt Lake City, UT 84104 Phone: 800-453-8494 www.wondoor.com Founded in 1962, the Won -Door Corporation introduced the world's most durable acoustically rated folding partition. In 1977 the company pioneered the development of the first-ever accordion type, fire rated horizontal sliding door. Today, more than 40 years later, Won -Door remains the industry leader in the manufacture of fire doors and moveable firewalls. Technology developed by Won -Door engineers continues to influence the building products and fire protection industries. Setting the standard The first to gain universal acceptance The development of the accordion type, horizontally sliding fire door — as manufactured by the Won -Door Corporation — has had a profound influence on the model code requirements that regulate their use, leading to its universal acceptance for use in virtually any means of egress application. The first to be UL listed The Won -Door FireGuard was the first accordion type fire door to successfully pass nationally recognized tests to withstand the passage of fire. Won -Door FireGuard products are listed by Underwriters Laboratories Inc. (UL) for up to 3 hours as a rated door assembly and 2 hours as a moveable fire wall. Opening protective for a non -rated glass entrance to a tenant suite. Still on the cutting-edge Only the Won -Door FireGuard uses a state-of-the-art microprocessor activated control system to guarantee reliability and enhance door function. This technology provides almost limitless opportunities for electronic communication, supervision, alarm activation and more. Engineered to fit YOUR needs Building codes encourage larger openings so why be limited by traditional forms of opening protectives like roll -down shutters or swing -type doors? The custom-made Won -Door FireGuard fire door can accommodate virtually any opening. Capable of spanning wide openings and heights up to 28 feet* — even radial configurations are possible. Best of all, the single- or bi-parting doors are installed in the open position and fold to just inches per foot behind pocket doors that you can design to blend with the surrounding architecture. Area separation between the old and new BWI Airport terminal. Superior performance, superior service More than twenty branch sales offices and two Regional Sales Offices, plus a highly skilled team of designers, engineers and field technicians, provide product service and support across the'United States. Thoroughly knowledgeable about building code as well as construction, our sales force can be relied upon to guide you every step of the way so you can get your ideas off the drawing board and into existence. Typical applications include: Area Separation Atrium Separation Corridor Separation Elevator Lobby Separation Horizontal Exits Occupancy Separation Safe Areas of Refuge Smoke Barrier Smoke and Draft Control Vertical Exit Enclosure Separation Smoke Compartmentation Stage Proscenium Protective Vertical Opening Protective The same Won -Door FireGuard fire doors are used in this elevator lobby/stairwell to satisfy two code enclosure requirements — protection of a vertical opening as well as elevator lobby separation. APPLICATION Elevator Lobby Separation in Type R Occupancy PROJECT Gold Country Hotel & Casino LOCATION Oroville, California PROJECT ARCHITECT Varond Design Group Won -Door FireGuard fire doors are used to create unobtrusive, yet code -compliant, elevator lobbies that are compatible with the decor of this high-rise hotel and casino in Northern California. T., i Use Won -Door FireGuard in lieu of swing doors APPLICATION Vertical Opening Protective PROJECT Arizona State University Athletics Facility LOCATION Tempe, Arizona PROJECT ARCHITECT OWL Architects The architect wanted the natural light from the skylight of this three-story athletic building to filter through colorful banners and illuminate a display of athletic trophies and awards on the first floor. Using Won -Door FireGuard fire doors made this possible. "Fire doors" are not limited to just hollow metal swings. Won -Door FireGuard fire doors are code recognized and accepted anywhere an opening protective is required. Use Won -Door FireGuard in lieu of reducing the size of rated openings Rated openings in fire walls and fire barriers are permitted to be as large as 156 square feet, even in unsprinkled environments. The Won -Door FireGuard provides maximum design flexibility — beyond that of any other fire door or shutter. LA\ppAgaSatnz 08 7/WO Use Won -Door FireGuard in lieu of shutters By redefining what is typically described as an "atrium" Won -Door FireGuard fire doors meet the required fire separation between adjacent spaces while eliminating costly atrium requirements such as sprinklers and smoke evacuation systems. Use Won -Door FireGuard in lieu of fire -rated glass Won -Door FireGuard, the only microprocessor controlled fire door on the market, is the preferred solution for lower cost and clear openings. Some models are approved for use as an ASTM E-119 compliant moveable fire wall in non -egress openings in fire barriers. APPLICATION Area Separation PROJECT Provo City Library LOCATION Provo, Utah PROJECT ARCHITECT MJSA Architects A non -rated clerestory joins the renovated historic 1892 building with a large modern library addition. Combining the old and the new presented a code compliance challenge. Since the aggregate square footage exceeded the allowable area defined in the current code, a 2 -hour fire barrier - the Won -Door FireGuard - was used to separate a large portion of the historic renovation. By taking advantage of the approved wide span opening protective capabilities, historic ambiance and code compliance were easily accommodated. Listings & Approvals APPLICATION Elevator Lobby Separation/Access Control PROJECT San Diego International Airport LOCATION San Diego, California PROJECT ARCHITECT SPGA The Won -Door FireGuard fire door can be used to isolate and control a security breach as well as stop the spread of fire and toxic fumes. Means of Egress Applications APPLICATIONS 2003 IBC1 Building Code Reference 1008.1.2 exc #5 2006 IBC1 1008.1.2 exc #6 2006 NFPA 101 7.2.1.14 Performance Criteria 1008.1.3.3 1008.1.3.3 1Any application without occupant load limitation except H occupancies. Product Information MODEL NUMBER Door Assembly FireGuard FG20 HOURLY RATING 20 minutes TEST CRITERIA U.L 10B (ASTM E-2074)6 U.L. FILE NUMBER R6799 SINGLE OR BI -PARTING Both Available 7.2.1.14 MAX. OVERSIZE LABEL SIZE 28'0" (h) Unrestricted (w) Door Assembly FireGuard FG603 1 hour U.L. 10B (ASTM E-2074)6 R6799 Both Available 28'0" (h) Unrestricted (w) Door Assembly FireGuard FG903 1 1/2 hours U.L. 10B (ASTM E-2074)6 R6799 Both Available 28'0" (h) Unrestricted (w) Door Assembly FireGuard FG1803 3 hours U.L 10B (ASTM E-2074)6 R6799 Both Available 28'0" (h) Unrestricted (w) Wall Assembly FireGuard MFW14 1 hour U.L. 263 (ASTM E-119) R12272 Single Parting Only N.A. Wall Assembly FireGuard MFW24 2 hour U.L. 263 (ASTM E-119) R12272 Single Parting Only N.A. Automatic Closing Systems Can be used on dl Wn Door FireGuard models listed up la 3 boors U.L. 864 E92690 Can be used for both 3 Each door assembly, when required, complies with UL1784; and with the'exception of FG20, can be labeled as Temperature Rise (TR). See ESR1394. 4 MFW - Movable Fire Wall 5 This listing applies for use on all Won -Door FireGuard models. 6 Excluding cotton pad test. Other Won -Door FireGuard Listings and Reports ICC State of California Door Assemblies MFW San Francisco Dept. of Public Works City & County of Denver State of Wisconsin City of New York Listed Assemblies Oversized Assemblies Research Rep. ESR -1394 3261-357:001; 1080-357:100 387W18.2 M-8275 811003 N.A. MEA -127-79-M; MEA -124-79M; MEA -383-85-M M EA -377-86-M ; M EA -70-87-M ; M EA -69-87-M Them Standard features of the Won -Door FireGuard: 1. Exiting hardware Exiting hardware can be configured and placed where appropriate, including to accommodate persons with disabilities. 2. Leading edge obstruction detector The door will stop upon contact with an obstacle, pause, then re -seek the closed position. 3. Leadpost Doors can be prevented from closing and caused to re -open a preset distance by applying light pressure to the leadpost. 4. Single- or bi-parting doors A single door slides across the opening into a recessed jamb located on the opposite wall. The spanning of larger openings is possible by using the bi-parting configuration. The storage space is then divided on each side of the opening. 5. Pocket cover door Pocket cover doors can be designed by you to blend with any decor. 6. Track and trolley system This system allows the door to accommodate wide span openings. Curved configurations are also possible. 7. Thermal lockout feature Ambient temperature at the door is monitored and the operating device is automatically disabled if the environment becomes untenable. 8. Microprocessor A control unit located in the door's storage pocket provides continuous monitoring of door status. 9. Electronics The Won -Door FireGuard is a completely electronically supervised system utilizing solid state circuitry as well as a backup DC power supply. 10. Floor gasket and fire liner A tight -fitting floor gasket and fiberglass liner provide an impenetrable barrier against the spread of smoke and flames. 1.1. Modular design Modular design provides for in-place reparability using basic tools. 12. Materials Door panels are constructed of 24 -gauge steel with a standard finish of platinum enamel. s. Fire Safety by Choice WON -DOOR CORPORATION Salt Lake City, UT 84104 Phone: 800-453-8494 www.wondoor.com Specifying the Won -Door FireGuard Why Without the use of floor tracks or exposed hardware of any kind, these fire doors are the most trouble free product in the fire protection industry. • Design flexibility • Custom made to fit your design without compromising code requirements • Lower maintenance costs • Modular construction means in-place reparability • No parts exposed to wear and tear • Fewer service calls • Can be reset by building management by simply pushing a button • Backup power supply so door operates even during a power outage • Increase useable space • Code compliant • Access control options available • Often cost less than other solutions How • Our Design Manual containing a complete summary of architectural details and specifications is available for free from your local Won -Door representative. Or call 800-453-8494 to order. • The Won -Door FireGuard Product Catalog prepared to standard CSI format for use with most CAD systems is also available for download from our website at www.wondoor.com • Additionally, videos, in a variety of formats, can be downloaded from our online video archive. These informative short movies cover a range of topics from typical applications and product demos to technical topics and code compliance. Learn and earn AIA members can learn more about Won -Door products and earn credits by participating in a Won -Door seminar either online or in person. Contact your local representative for more information or visit www.wondoor.com and click on Continuing Education. For more information contact your local representative. Won -Door Co s oration FIREGUARD COLOR CHART Standard Color #55 Platinum Optional colors are not available. Wnn-nnnr rnrnnratinn 1 RFS South 14RO Wed Salt 1 akc City i kali R4104 (R001451_R494 www wnnelnnr cnm Rev 7/11 March 01, 2016 City of Tukwila Department of Community Development JAMES HILL 828 7TH AVE SE OLYMPIA, WA 98501 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0038 FOSTER HIGH SCHOOL - 4242 S 144TH ST Dear JAMES HILL, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: FIRE DEPARTMENT: Al Metzler at 206-971-8718 if you have questions regarding these comments. 1) Please provide the manufacturers data sheet for the actual fire door. 2) A smoke detector is required to be within 5 ft. of the opening on each side for door activation. Are the detectors currently existing or will new detectors be installed? Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)433-7165. Sincerely, rt24 Ripley Permit Technician File No. D16-0038 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY, PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0038 PROJECT NAME: FOSTER HIGH SCHOOL DATE: 06/08/16 SITE ADDRESS: 4242 S 144TH ST Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division Public Works ❑ plc Fire Prevention Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 06/14/16 Structural Review Required REVIEWER'S .INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required ❑ Denied (ie: Zoning Issues) Approved with Conditions (corrections entered in Reviews) DUE DATE: 07/12/16 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0038 DATE: 02/12/16 PROJECT NAME: FOSTER HIGH SCHOOL SITE ADDRESS: 4242 S 144TH ST X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: fr Ac )---r7 Building Division 111 S5 Ni4- 2-� ('c 9 Public Works p�M Gbh- 4//MIt Fire Prevention Er Structural Planning Division Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 02/16/15 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/15/16 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: I I Departments issued corrections: Bldg 0 Fire g\f Ping 0 PW 0 Staff Initials: 12/18/2013 Date: 6.2.2016 City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: D16-0038 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: Foster High School Project Address: 4242 S 144th St Contact Person: Liliana Cardenas RECEIVED CITY OF TUKWILA JUN 082016 PERMIT CENTER Summary of Revision: Phone Number: 206-901-8020 In response to Fire Department comments: 1. Manufacturer's reviewed shop drawings attached for actual accordion Fire Door to be installed. 2. Noted on A0.1 and stated herein: Smoke detectors at Foster High School revised 2014-2015. Smoke detectors passed inspection at High School and at existing Fire Door to be replaced's location. A smoke beam detector is also located in the area of the fire door. Drawing Revisions: 1. Width and height of Accordion Fire Door revised to 8'-6" wide x 9'-0" high. Details are revised to reflect this. 2. Remaining clouded changes on the drawings are clarifying detail bug locations, exit door locations, added note to state no change in occupant load. Sheet Number(s): A0.1, A2.1, A9.1. Revision date noted under Revisions in Titleblock "Cloud" or highlight all areas of revision includin date of revision Received at the City of Tukwila Permit Center by: ri Entered in TRAKiT on ly - f 0 " 1(/ W:\Permit Center \Templates\Forms\Revision Submittal Form.doc Revised: August 2015 Ju) FORMA CONSTRUCTION COMP " NY Home Espanol Contact. Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I .A -Z Index Help My LET Workplace Rights Trades & Licensing FORMA CONSTRUCTION COMPANY Owner or tradesperson Principals PHILLIPS, JAMES EDWARD, PRESIDENT PHILLIPS, ANDREW JAMES, VICE PRESIDENT MUNSON, JACE KELLER, SECRETARY AB SERVICE COMPANY LLC, AGENT Doing business as FORMA CONSTRUCTION COMPANY WA UBI No. 600 604 496 PO BOX 11489 OLYMPIA, WA 98508-1489 360-754-5788 THURSTON County Business type Corporation Governing persons ANDREW PHILLIPS JACE K MUNSON; JAMES A PHILLIPS; License Verify the contractor's active registration / license I certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. FORMACC878OR Effective — expiration 09/19/2013— 09/19/2017 Bond ............... Safeco Ins Co of America Bond account no. 69S010324 $12,000.00 Received by L&I Effective date 09/19/2013 09/18/2013 Expiration date Until Canceled Insurance Wausau Underwriters Ins Co $1,000,000.00 Policy no. TB2-Z91-459645-035 Received by L&I Effective date 07/08/2015 07/09/2015 Expiration date 07/09/2016 Wausau Underwriters Ins Co $1,000,000.00 Policy no. TB2-Z91-459645-034 Received by L&I Effective date 06/17/2015 07/09/2014 Expiration date 07/09/2016 Page 1 of 3 uS-09r ((32-f( https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600604496&LIC=FORMACC878OR&SAW= 6/28/2016 FOSTER HIGH SCHOOL FIRE DOOR TUKWILA SCHOOL DISTRICT 4242 SOUTH 144TH STREET TUKWILA, WA 98168 LE COPY Permit No. V , 00% Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation Q any adopted coda or ordinance. Receipt of approvod Field Copy and conditions is acknowlodyod: By:_ Date: City of Tukwila BUILDING DIVISION PROJECT INFORMATION DESIGN TEAM OWNER ARCHITECT Tukwila School District 4242 South 144th Street Tukwila, Washington 98168 206.242.9097 PROJECT LOCATION Foster High School 4242 South 144th Street Tukwila, Washington 98188 206.901.7600 TAX PARCEL No: 1523049108 AUTHORITIES HAVING JURISDICTION City of Tukwila Department of Community Development 6300 Southcenter Blvd., #100 Tukwila, Washington 98188 building@tukwilawa.gov 206.431.3670 Fax:206.431.3665 KMB design groups, inc. p.s. 828 -7th Avenue S.E. Olympia, Washington 98501 Jeff Feeney jefffeeney@kmbdesign.com James Hill jameshill@kmbdesign.com DRAWING ABBREVIATIONS L 0 d. R AB NC ACOUS ACT ACC ADD ADJ AFF ALUM ALT APPROX ARCH BD BLDG BLK BLKG BM BRG BTM AND ANGLE AT CENTER LINE DIAMETER FOOT (FEET) INCH PENNY (NAILS) POUNDS PLATE or PROPERTY LINE ANCHOR BOLT AIR CONDITIONING ACOUSTIC(AL) ACOUSTICAL CEILING TILE ACCESSIBLE ADDITIONAL ADJACENT/ADJUSTABLE ABOVE FINISH FLOOR ALUMINUM ALTERNATE APPROXIMATE ARCHITECT(URAL) BOARD BUILDING BLOCK BLOCKING BEAM BEARING BOTTOM BTWN BUR CAB CFCI CJ CL OR ti CLG CLR CMU COL CONC CONN CONST CONT CORR CTSK CTR DBL DEPT DF DIA OR O DIAG DN DO DR DHM DWG BETWEEN BUILT-UP ROOF CABINET CONTRACTOR FURNISHED/ CONTRACTOR INSTALLED CONSTRUCTION JOINT CENTER LINE CEILING CLEAR CONCRETE MASONRY UNIT COLUMN CONCRETE CONNECTION CONSTRUCTION CONTINUOUS CORRIDOR COUNTERSINK CENTER DOUBLE DEPARTMENT DOUGLAS FIR/ DRINKING FOUNTAIN DIAMETER DIAGONAL DOWN DITTO (REPEAT) DOOR DETENTION HOLLOW METAL DRAWING (E) EA EF EIFS EJ EL ELEC ELEV EN ENG EQ EQUIP ES EXP EXIST, EXG EXT FA FAB FIN FDN FE FEC FF FHWS FLG FLR FOC FOM DRAWING INDEX ARCHITECTURAL A0.1 COVER SHEET A2.1 REFERENCE FLOOR PLAN A2.2 REFERENCE ACTIVITIES WING PARTIAL FLOOR PLAN A9.1 SECTION AND DETAILS EXISTING EACH EXHAUST FAN EXTERIOR INSULATION AND FINISHING SYSTEM EXPANSION JOINT ELEVATION ELECTRICAL ELEVATION EDGE NAIL ENGINEER EQUAL EQUIPMENT EACH SIDE EXPANSION EXISTING EXTERIOR FIRE ALARM FABRICATE(ION) FINISH FOUNDATION FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISH FLOOR FLAT HEAD WOOD SCREW FLASHING FLOOR FACE OF CONCRETE FACE OF MASONRY FOS FOW FP FR FRMG FRT FS FT FTG GA GALV GB GLB GWB HB HC HD HDW HDR HGR FACE OF STUD FACE OF WALL FIREPROOF FIRE RESISTANT FRAMING FIRE -RETARDANT -TREATED FAR SIDE FOOT(FEET) FOOTING GAUGE GALVANIZED GRAB BAR GLUE LAMINATED BEAM GYPSUM WALLBOARD HOSE BIBB HOLLOW CORE! HANDICAP HOLD DOWN HARDWARE HEADER HANGER HORIZ OR H HORIZONTAL HM HOLLOW METAL HR HOUR HTG HEATING HTR HEATER HOT WATER HEATER HEIGHT INSIDE DIAMETER INSIDE FACE HWH HT ID IF DRAWING SYMBOLS ac0 DETAIL NUMBER SHEET NUMBER WHERE DETAIL APPEARS WALL SECTION DESIGNATION SHEET NUMBER WHERE SECTION APPEARS 011GBUILDING SECTION DESIGNATION SHEET NUMBER WHERE SECTION APPEARS 1 (xx,Noc ) ELEVATION NUMBER DESIGNATION — DIRECTION IN ROOM SHEET NUMBER WHERE ELEVATION APPEARS ROOM NUMBER FOR FINISH SCHEDULE DOOR NUMBER FOR DOOR SCHEDULE WINDOW TYPE WINDOW NUMBER CEILING DESIGNATION CEILING HEIGHT IN INCH NO INSUL INSULATION NS INT INTERIOR NTS INT INTERIOR OC JAN JANITOR OD JST JOIST OF JT JOINT OFCI KIT KITCHEN LAT LATERAL OFOI LB POUNDS LF LINEAL FEET OH L LENGTH/LONG OPNG LOC LOCATION OPP LT LIGHT ORNT M.C. METAL CHANNEL PAR MR MOISTURE RESISTANT P/C MATL MATERIAL PERP MAX MAXIMUM PLAM MB MACHINE BOLT PL MECH MECHANICAL PSF MEZZ MEZZANINE PWD MFR MANUFACTURER PSI MIN MINIMUM PT MISC MISCELLANEOUS QTY MR MOISTURE RESISTANT RAD OR R MTD MOUNTED REF MTL METAL REFL (N) NEW REFR. NIC NOT IN CONTRACT REINF NUMBER NEAR SIDE NOT TO SCALE ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OWNER FURNISHED/ CONTRACTOR INSTALLED OWNER FURNISHED/ OWNER INSTALLED OVERHANG OR OVERHEAD OPENING OPPOSITE ORIENTATE(ION) PARALLEL PRECAST CONCRETE PERPENDICULAR PLASTIC LAMINATE PLATE OR PROPERTY LINE POUNDS PER SQUARE FOOT PLYWOOD POUNDS PER SQUARE INCH PRESSURE TREATED QUANTITY RADIUS REFERENCE REFLECTED REFRIGERATOR REINFORCED REQD RHWS RM RO SC SCH SF SHT SHTG SIM SP SPS SPEC SQ SS SSK STD STGR STL STR SUSP SV SYM T T&B T&G TB THK TN PROJECT DESCRIPTION FOSTER HIGH SCHOOL IS A 9TH THROUGH 12TH GRADE SCHOOL WITH 845 STUDENTS. THIS PROJECT INVOLVES REPLACING THE EXISTING FIRE DOOR IN THE ACTIVITIES WING. BUILDING OCCUPANCY CLASSIFICATION - EDUCATIONAL (GROUP E) BUILDING CODE SUMMARY APPLICABLE CODES: INTERNATIONAL & NATIONAL CODES: 2012 INTERNATIONAL BUILDING CODE 2009 ICC ! ANSI A117.1 2012 INTERNATIONAL MECHANICAL CODE 2012 INTERNATIONAL FIRE CODE 2012 UNIFORM PLUMBING CODE 2008 NATIONAL ELECTRICAL CODE WASHINGTON STATE CODES: 2012 WASHINGTON STATE ENERGY CODE CHAPTER 51-11 WAC WASHINGTON STATE CODES AMENDMENTS: WA STATEAMENDMENTS TO THE 2012 IBC CHAPTER 51-50 WAC WA STATEAMENDMENTS TO THE 2012 IMC CHAPTER 51-52 WAC WA STATEAMENDMENTS TO THE 2012 IFC CHAPTER 51-54 WAC WA STATEAMENDMENTS TO THE 2012 UPC CHAPTER 51-56 AND 51-57 WAC BUILDING CODE NOTES 1. EXISTING OPENING IS IN A 2 HOUR RATED WALL. ALL OPENINGS ARE REQUIRED TO HAVE A 90 MINUTE RATING. REFERENCE FLOOR PLANSHEET A2.1 FOR ADDITIONAL INFORMATION REGARDING RATED WALL LOCATIONS. 2. SMOKE DETECTORS REVISED 2014 - 2105. SMOKE DETECTORS PASSED INSPECTION IN FOSTER HIGH SCHOOL AND AT EXISTING FIRE DOOR TO BE REPLACED'S LOCATION. A SMOKE BEAM DETECTOR IS ALSO LOCATED IN THE AREA OF THE FIRE DOOR. CONTRACTOR NOTES 1. FOR AV AS -BUILT DRWING INFORMATION, CONTACT: Liliara Cardenas Director of Maintenance and Operations TukMila School District Card.nasL@tukwila.wednet.edu 206.901.8020 2. CONTRACTOR TO VERIFY POWER AND FIRE ALARM CONNECTIONS PRIOR TO INSTALLATION. REQUIRED ROUND HEAD WOOD SCREW ROOM ROUGH OPENING SOLID CORE SCHEDULE SQUARE FOOT (FEET) SHEET SHEATHING SIMILAR SPACE(ING) SPACES SPECIFICATIONS SQUARE STAINLESS STEEL SERVICE SINK STANDARD STAGGER STEEL STRUCTURAL SUSPENDED(TION) SHEET VINYL SYMMETRICAL TOP TOP AND BOTTOM TONGUE AND GROOVE TACK BOARD THICK TOE NAIL TOC TOP TOM TOJ TOS TOW TPD TSCD TS TYP UBC UON VCT VERT OR V VIF W W/ W/0 WB WC WD WIN WP WWF YD TOP OF CONCRETE TOP OF PAVING TOP OF MASONRY TOP OF JOIST TOP OF SHEATHING TOP OF WALL TOILET PAPER DISPENSER TOILET SEAT COVER DISPENSER TUBE STEEL TYPICAL UNIFORM BUILDING CODE UNLESS OTHERWISE NOTED VINYL COMPOSITION TILE VERTICAL VERIFY IN FIELD WIDE (WIDTH) WITH WITHOUT WHITE BOARD WATER CLOSET WOOD WINDOW WATER PROOF / WORK POINT WELDED WIRE FABRIC YARD PROJECT SITE SEPARATE.: PERMIT i CUIRcD FOR: (� Mechanical Qi Electrical pa, Plumbing 074 Gas Piping City of Tukwila �Dt iNG DIVISION REVIEVVED FOR CODE COMPLNPPROVIANCE DE ,NN 232016 -L/ of YUi0Mla BUILDING DIVISION NORTH VICINITY MAP SEATTLE REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j NORTH AREA MAP RECEIVED CITY OF TUKWILA CORRE TION JUN 08 2016 LTR# PERMIT CENTER ...u.a. S...... •.SUSS. SSSS... U...... ....... design groups, inc. p.s. architecture education facilities group justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 JADES ILL STATE OF WA/MN: ON KMB Project# E1564 W LL J V O N V D cr) 0 0 cit) c/1 W Fatni tit) O � ORIGINAL SHEET SIZE = 24 x 36 HALF SIZE REDUCTIONS .11 x 17 REVISIONS: 06-02-2016 DATE: 02-10-2016 CONSTRUCTION DOCUMENTS SHEET NO. A0.1 P I V-00St2 1111111111111111111111111111111111111111111111111w. 1. ALL THE EXITS AND OCCUPANCY LOADS ARE REMAINING THE SAME. THERE IS NO CHANGE. CYR SEPARATION REQUIREMENTS REFER =TO .PIAN Si T Ai Q9i.! AMITIVE ALTERNA'i MAW, ; t 2—HR:PROSCENIUf WALL 1ORALL- ,. 7fIeR:2::7dp ► S tltO ON p;4;, IIIII II. In iIICIIi uUNIC5Y13143 l MT381 fAt12I NEVO [Eg1� I>;551 ariliiiIi�er111111•111i 1iiirthiII _WWIBMlatiiiearakdIPLO AREA OF WORK MiiiirEk r✓�,i' 9'I�INlIlr1�1�11I�Y® _____ ___ y /% fr tl1./N/YY.1 i .. Y. Ord L331 1613+1 sna Illl111lsi®1®1111I11MINNINMIN II BII S:R; "., 1 . ew�il�ia4 , 1• � ` ::' A 10'RM „:Nr' w�MYir ' wirr- � -.rirr -•.. R .1'4411p SEE NOTE 1 I PROJECT NORTH c!) REFERENCE FLOOR PLAN - ACTIVITIES AND ACADEMIC WING SCALE: NOT TO SCALE RE CITY OF TUKWILA JUN 08 2016 PERMIT CENTER u.s.... Si..... =MENEM EMEMEME design groups, inc. p.s. architecture education facilities group Justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 JAWED HLL STATE OF WASHINGTON KMB Project# E1564 W 00 4 coitt Z Q O g cnN CN er I— ORIGINAL SHEET SIZE = 24 x 36 HALF SIZE REDUCTIONS 11 x 17 REVISIONS: 06-02-2016 DATE: 02-10-2016 CONSTRUCTION DOCUMENTS SHEET NO. A2.1 11 b . .}I cu /% fr tl1./N/YY.1 i .. Y. Ord L331 1613+1 sna Illl111lsi®1®1111I11MINNINMIN II BII S:R; "., 1 . ew�il�ia4 , 1• � ` ::' A 10'RM „:Nr' w�MYir ' wirr- � -.rirr -•.. R .1'4411p SEE NOTE 1 I PROJECT NORTH c!) REFERENCE FLOOR PLAN - ACTIVITIES AND ACADEMIC WING SCALE: NOT TO SCALE RE CITY OF TUKWILA JUN 08 2016 PERMIT CENTER u.s.... Si..... =MENEM EMEMEME design groups, inc. p.s. architecture education facilities group Justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 JAWED HLL STATE OF WASHINGTON KMB Project# E1564 W 00 4 coitt Z Q O g cnN CN er I— ORIGINAL SHEET SIZE = 24 x 36 HALF SIZE REDUCTIONS 11 x 17 REVISIONS: 06-02-2016 DATE: 02-10-2016 CONSTRUCTION DOCUMENTS SHEET NO. A2.1 • .14'=10 t/.4 9 9"..:.. 28 'O'.... 224'-01 ACADEMIC wIN�` 28:-d ,.. 10 to.1/2! PROJECT LOCATION r. �� 1•.1. W, IN"C, aan11aaaarr.osaMMnmsa;zaa4442M441.asmuws41anaai4MM44uaflnauaawnaaunann4444+ertaamca1..4nu4snx:analdawanaaar4:acarnr4aaAIaa441MIA anllnnrtu�ICNt1114M4 urraa4na9M..vn4.aaaonxa4=1444anaarvxIHaack µ, 67-11711' i"1 P� I ' t,),11.'IL O/l,�.e10. A21, I i mown,1asulw1>nlsimmummeinsiono wum:vsucez +xaxttri1uuuiaae"aaareer4unxucnax RELOCATION PAO MMODIFICAT1ON. Of EXISTING BLEACHERS NIC • jx'1 J HDCP �C�r!?i �111�i1�11'4 L®J ISI•"� j' OEt CH i i I>N[ it l �l i1 041H. ice QCOR, 141 AL(GN'RatQliS 43.1k. qte • t 1O` O" ! • 1SOSPENOED,• IRES ! t E 0 ,GYPSUM :EMEBOARD': aoq. .wa...wv.0.�lw is ran, woo AND 'MOWS V 110111.161B11.1.0# €• XQOSED ... POUR• JOINT 1 .$EE titer A243 FOR:06464/,L NOTES TO POOR PLANS' MN WE , ; i ��itrI1 r�'/f��/tri®�� ®r��s�� �rzi, W,474rrSSlttlli'%�s/��s./+' b011111F1 7.1 A RELOCATE 5aIST NETAL.CABINETS HOUSEKEEPING PAD �SEE.MECH r let 1111411 ABOVE`.oDOR aa,.. 1111..0.4 "410110k ®g �! LIE.. #11111111L11111111111111" `i1w®ice unrrntnnaanurs�ana�rrat�rgs�nlarxaenst�n�smt+ IHSMPEARIN 400, STAIR: A1# k • za NORTH REFERENCE FLOOR PLAN -PARTIAL ACTIVITIES WING SCALE: NOT TO SCALE ACTI 'ff MAIN FLOOR, :soke CITY OF TUICWIL JUN 08 2016 ERMIT CENTER ■.■■m■. ma'.... MM•MMEM =EMMEN MEEEMEM design groups, inc. p.s. architecture education facilities group justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 JAIL Fit STATE OF WASHINGTON KMB Project# E1564 4242 SOUTH 144TH STREET 00 co 00 dxx� F�— ORIGINAL SHEET SIZE= 24x 36 HALF SIZE REDUCTIONS =11 x 17 REVISIONS: 06-02-2016 DATE: 02-10-2016 CONSTRUCTION DOCUMENTS SHEET NO. A2.2 MEIGI EDGE OF NEW WALL FINISH TO ALIGN WITH EDGE OF EXISTING WALL FINISH (2) 4" x 4" "J" BOXES RECESSED MOUNTED 12" BELOW BOTTOM OF SOFFIT SLIDING JAMB BY WON -DOOR -Ararity/ Forvor,ArkerAte Aro 2 -HOUR WALL CONSTRUCTION (2) LAYERS 5/8" TYPE 'X' GWB OVER 18 GA 3-5/8" STEEL FRAMING ON -DOOR FIREGUARD CROSS CORRIDOR COMPRESSED STACK VERIFY SIZE IN FIELD S LID 0 IN •U AC IN PLACED 5" FROM THE FACE OF THE POCKET BY OTHERS FLOATING JAMBS BY WON -DOOR FLAT LEADPOST/POCKET COVER DOOR BY WON -DOOR. NO TILE, STONE, METAL FACING, BASE OR MOLDING MATERIAL ALLOWED. 2 3/8" X 1 1/2" STRIKER JAMBS BY WON -DOOR. FINISH WALL TO TOP OF FINISHED FLOOR -NO BASE OR MOLDING MATERIAL ALLOWED. CONTINUOUS BACKING 2 -HOUR WALL CONSTRUCTION (2) LAYERS 5/8" GWB OVER 3-5/8" STEEL FRAMING i 1'-6 3/8" OO 9 N PAINT AND TEXTURE TO MATCH EXISTING, TYP. ALIGN WITH OPPOSITE WALL 2 -HOUR WALL CONSTRUCTION (2) LAYERS 5/8" GWB OVER 3-5/8" STEEL FRAMING 1/2" DIA. THREADED RODS WITH NUTS & WASHERS BY WON -DOOR. 12" FROM EACH END AND SPACED 2'-0" MAX. IN THE OPENING. PRE -FINISHED WHITE TRACK ASSEMBLY BY WON -DOOR. 1'-6 3/8" 57/8"57/8" / / POCKET WALLS TO BE PLUMB TO WITHIN ±1/8" TO MAINTAIN PROPER REVEAL AND CLEARANCE AT LEADPOST. EXISTING STRUCTURE ABOVE ct co NEW DOOR HEAD SCALE: 1" =1'-0" L C =110611 CU= =I 1111111001 1'-0" MEM IMMO nuall rtml ft= —1 II r DEMO NEW 110001111 I I J DEMOLISH EXISTING JAMB REMOVE EXISTING AUTOMATIC DOOR ABOVE ENLARGED PLAN SCALE: 1/2" =1'-0" L _ EXISTING STRUCTURE ABOVE REMOVE EXISTING FIRE DOOR REMOVE EXISTING FRAMING EXISTING WALL BEYOND DEMOLITION DOOR HEAD 4 /ba -rr f,l ark. I . S'�GM U CFuI�Y4ga. 'rob), vw etam 'jjiir 4 ` Al RSI t aiepor r07; x- ,I G� TQFY i II + '44 4.11f f4rV1 , MFU kJ4 P AtagsteiliWASIi 4.2 E.:. ! �i1isew� moan a4iY:i_b. "�rawr�,cw �mtm�.w .. A ,/T'4115Da, 0.44- F.0404'?. . . 04,1 'atlut-rriri.0 PrtrAZ -*egtOK i:[ REFERENCE HALL SECTION SCALE: NOT TO SCALE RECEWED CITY OF TUKWILA JUN 08 2016 PERMIT CENTER 1111111111111111111 ■■■■■■■ U...... U...... ■■■■■■■ design groups, inc. p"s. architecture education facilities group justice facilities group security design group 906 Columbia St SW, Suite 400 Olympia, WA 98501 360.352.8883 JAMES FILL STATE OF WASHINGTON KMB Project# E1564 LLO CC, E° im= m cif) o uff) o W H inn= eco Cr, d'r' 00 = ?cc, =s N = d' ORIGINAL SHEET SIZE = 24 x 36 HALF SIZE REDUCTIONS -11 x 17 REVISIONS: 06-02-2016 DATE: 02-10-2016 CONSTRUCTION DOCUMENTS SHEET NO. A9.1