Loading...
HomeMy WebLinkAboutPermit D16-0073 - DIECUT PRINTERS - TENANT IMPROVEMENTDIECUT PRINTERS 345 ANDOVER PARK E SUITE 100 D16-0073 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Of (40— 0073 Project No. Date Application Accepted: Date Application Expires: 0r -)-1 -( f (For o,i lce use oil CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 345 Andover Park East, Tukwila, WA 022340-0040 King Co Assessor's Tax No.: Tenant Name: Diecut Printers Suite Number: all Floor: PROPERTY OWNER Name: Alene Torossian - Broderick Architects Name: Daniel Diederichs City: Seattle State: WA Zip: 98134 Address: 503 S. Michigan Street Email: alene@broderickarchitects.com City: Seattle State: WA Zip: 98108 CONTACT PERSON — person receiving all project communication Name: Alene Torossian - Broderick Architects Address: 55 S. Atlantic Street, Suite 301 City: Seattle State: WA Zip: 98134 Phone: 206.682.7525 Fax: Email: alene@broderickarchitects.com GENERAL CONTRACTOR INFORMATION Company Name: Not Yet Selected Address: Company Name: Architect Name: Kevin Broderick City: Q „cam( L,Qa City: State: City: Seattle State: WA Zip: Phone: Fax: Email: kevin@broderickarchitects.com State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: HAApplications\Fornu-Applications On Line '2011 Applications\Pennit Application Revised - 8.9.11.docx New Tenant: 0 Yes ..No ARCHITECT OF RECORD Name: 6 o_ae1 i G kis Company Name: Broderick Architects Company Name: Architect Name: Kevin Broderick City: Q „cam( L,Qa Address: 55 S. Atlantic Street, Suite 301 City: Seattle State: WA Zip: 98134 Phone: 206.682.7525 Fax: Email: kevin@broderickarchitects.com State: ENGINEER OF RECORD Name: 6 o_ae1 i G kis Address: , Company Name: S.) . City: Q „cam( L,Qa Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19..n27.095) Name: 6 o_ae1 i G kis Address: , 5. N.1 S.) . City: Q „cam( L,Qa State: Rip J Zip:,/ -10 DvrLvll`tls`r'GKPTI 111`IL110'401.0o IV Valuation of Project (contractor's bid price): $5 Y CO Describe the scope of work (please provide detailed information): Existing office / warehouse space. All existing interior walls to be demo and provided with new GWB partitions, new plumbing, new ceiling, new power/data, new lighting/switching, and interior finishes. (No exterior Work) Existing Building Valuation: $ `, 33$ t 400. OcD Will there be new rack storage? ❑ Yes 0.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: O Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes g No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:VApplications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Existing Interior Remodel Addition to Existing Structure New Type of Construction per . IBC Type of Occupancy per IBC 1'` Floor 8,243 8,243 VB 0 & F 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: O Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes g No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:VApplications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx u Li wurtuii5rL Ltivit- 111 V AJAIYINTIAJII._ zvo=4J3-carry — — Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ... Valley View ❑ .. Renton ❑ ...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond ❑ .. Insurance ❑ .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way ❑ Non Right-of-way 0 0 ...Total Cut 0 ...Total Fill cubic yards cubic yards 0 .. Geotechnical Report 0 .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) 0 ...Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone 0 .. Storm Drainage 0 ...Sanitary Side Sewer ❑ .. Abandon Septic Tank 0 .. Grease Interceptor ❑ ...Cap or Remove Utilities ❑ .. Curb Cut ❑ .. Channelization ❑ ...Frontage Improvements ❑ .. Pavement Cut 0 .. Trench Excavation ❑ ...Traffic Control ❑ .. Looped Fire Line 0 .. Utility Undergrounding 0 ...Backflow Prevention - Fire Protection " Irrigation " Domestic Water " 0 ...Permanent Water Meter Size... " 0 ...Temporary Water Meter Size .. 0 ...Water Only Meter Size ❑ ...Sewer Main Extension Public 0 ❑ ...Water Main Extension Public 0 WO # WO# WO # Private ❑ Private 0 0 ...Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx PERMIT A?PLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Date: ` J . 1.•• t( Print Name:le a N 6Ne Day Telephone: r.-476" ' 65Z.' 7'77 Mailing Address: . 4*"3e9t H:\ApplicationsWorms-Applications On Line \2011 Applications'Pern it Application Revised - 8-9-1I.docx 5 :157k 1. -E 14/s. 'CO 134 - City State Zip DESCRIPTIONS ( ACCOUNT I QUANTITY PermitTRAK 1 PAID $3,822.93 D16-0073 Address: 345 ANDOVER PARK E Unit100 Apn: 0223400040 $3,822.93 DEVELOPMENT $3,641.10 PERMIT FEE R000.322.100.00.00 0.00 $3,636.60 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.S0 TECHNOLOGY FEE $181.83 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R8443 R000.322.900.04.00 0.00 $181.83 $3,822.93 Date Paid: Wednesday, May 11, 2016 Paid By: BRODERICK ARCHITECTS Pay Method: CHECK 17969 Printed: Wednesday, May 11, 2016 9:04 AM 1 of 1 r! IISYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID PermitTRAK $2,363.79 D16-0073 Address: 345 ANDOVER PARK E 120 Apn: 0223400040 $2,363.79 DEVELOPMENT $2,363.79 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R7973 R000.345.830.00.00 0.00 $2,363.79 $2,363.79 Date Paid: Monday, March 21, 2016 Paid By: BRODERICK ARCHITECTS Pay Method: CHECK 17631 Printed: Monday, March 21, 2016 10:56 AM 1 of 1 CPSYSTEMS Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0223400040 Permit Number: D16-0073 345 ANDOVER PARK E Unit100 Issue Date: 5/11/2016 Permit Expires On: 11/7/2016 Project Name: DIECUT PRINTERS Owner: Name: Address: Contact Person: Name: Address: SRO PROPERTIES INC 1411 4TH AVE #1315 , SEATTLE, WA, 98101 ALENE TOROSSIAN 55 S ATLANTIC ST SUITE 301, SEATTLE, WA, 98134 Contractor: Narye; n 4ATTLE CONST RESOURCES INC Addreess: 414 ELLIOTT AV W , SEATTLE, WA, Phone: (206) 682-7525 Phone: (206) 282-7500 98119 •W '.} -_ 14 n(Qj License No: SEATTCR101BZ Expiration Date: 2/5/2018 Lender: Name: DANIEL DIEDERICHS Address: 503 S MICHIGAN ST, SEATTLE, WA, 98108 DESCRIPTION OF WORK: EXISTING OFFICE/WAREHOUSE SPACE. ALL EXISTING INTERIOR WALLS TO BE DEMOLISHED AND REPLACED WITH NEW GWB PARTITIONS, NEW PLUMBING, NEW CEILING, NEW POWER/DATA, NEW LIGHTING/SWITCHING AND INTERIOR FINISHES. NO EXTERIOR WORK Project Valuation: $350,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: YES Type of Construction: VB Electrical Service Provided by: TUKWILA FIRE SERVICE Fees Collected: $6,186.72 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2012 2012 2012 2012 2012 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: (A)fi \Zg Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:_ Print Name: --_J2 c't#4 Date: .1 tt This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: Notify the City of Tukwila Building Division prior to placing any concrete. This procedure is in addition to any requirements for_special inspection. 8: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8-feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. Periodic special inspection is required during anchorage of storage racks 8 feet or greater in height. 9: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 14: Preparation before concrete placement: Water shall be removed from place of deposit before concrete is placed unless a tremie is to be used or unless otherwise permitted by the building official. All debris and ice shall be removed from spaces to be occupied by concrete. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 21: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 20: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 17: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 18: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 19: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 22: Maintain fire extinguisher coverage throughout. 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 25: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 26: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 27: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 31: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 28: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 33: An approved manual fire alarm system including audible/visual devices and manual pull stations is required for this project. The fire alarm system shall meet the requirements of Americans With Disabilities' Act (I.B.C.), N.F.P.A. 72 and the City of Tukwila Ordinance #2437. 34: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 35: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 37: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. 30: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 38: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 39: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 40: ***PUBLIC WORKS PERMIT CONDITIONS*** 41: Prior to final of D16-0073 permit the applicant shall apply for a separate PUBLIC WORKS TYPE C permit for: a) installation of a Reduced Pressure Principle Assembly (RPPA) on domestic water for premise isolation; b) installation of a DDCVA on fire prevention line; c) sediment removal/vacuum cleaning of the four existing catch basins in the parking lot; one of them needs to be sealed and re -grouted. 42: A separate electrical permit may be required if the licensed electrician hired by the property owner determines that the existing sump pump inside the catch basin in front of the loading dock needs electrical work to bring wiring up to code. 43: Items a, b and c shall be installed or bonded before D16-0073 Public Works final can be given. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0301 CONCRETE SLAB 1400 FIRE FINAL 0409 FRAMING 0606 GLAZING 0502 LATH & GYPSUM 1600 PUBLIC WORKS FINAL 0603 ROOF/CEILING INSUL 0406 SUSPENDED CEILING 0601 WALL INSULATION 0413 WALL SHEATHING/SHEAR INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro'ect:Ty D ieCu� R_ l�rrgs a of Inspection: K. 1L1)! f6 KA/AL Address: 34S—./4Alb012 03‘ c Date Called: Special Instructions: Date Wante >/ a.m. Pall - Request Phone No: rii Approved per applicable codes. L__J Corrections required prior to approval. COMMENTS: OK 7-6 „rA714//___ Date: H n, 6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. bt0-0073 �z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projec . i.ec03 �rh�4,e•rS Type of Inspection: — k— 1 M A?); s I � *�akk. r Date Called: SpecialDpeIns'tr'uc� cti`ons:DO 111-- 1.. Date Wanted: I v (� .m. Requester: Phone No: Approved per applicable codes. l__J Corrections required prior to approval. COMMENTS: Inspector/V-- : D70 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Prot: ,.�� Type of Inspectioon: /R Adddreess: l klbOte'r PA -0414 Da e Called: Special Instructions: Date Wan t�,d: / �3'� �o a.m� p.m. Requester: Phone No: Approved per applicable codes. I I Corrections required prior to approval. COMMENTS: -e F GO.i4fe- A1919001/41:4Z- Inspector: Date: e /C i REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. imINSPECTION RECORD Retain a copy with permit ' I1J3' ION NO. PERMIT NO. 067? CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pro'jeecct: �� b/CCor� Pe/i6768 Type of Inspection: 6 t ziftr6- Address:_ s � Ai Ate C Date Called: Special Instructions: Date Wanted: a.m. Requester: Phone No: ,Approved per applicable codes. D Corrections required prior to approval. COMMENTS: Inspector: Date: �} v/ 23 16 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit .1)/6 -oU1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: 'N P A r 12S T e of Inspection: i y ��1nr6- i L Address: 3ysA„ke,,� ave 4— Date Called: Special Instructions: .r I/evi Date Wantem • Requester: -426 K Phone No: 23 -]/14-33ZS- ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: ii))13120-abe Appi imL Peov me --e �,�-T/Jc� 2t/i4f _ Pecf v Inspector: /171,4 Date: 9 3 /6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Cl INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 /c -a73 vd Project: Type of Inspection: Address: 3--1S Axitx. (%,dC c Date Called: Special Instructions: Date Want ti76/16 Requester: Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: APPPAAAL (9e7A)77-1-- -OPJ rl;e6 & 7 aK To atc---tz Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSP CTION NO. INSPECTION RECORD Retain a copy with permit i -an 3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: i&&irr (IJf S Type of Inspection: - frbt2'imf Ad ress: tom- 4110/6f PAIVZ 6' Date Called: Special Instructions: (/A,, r.. /60 Date Wan006 �'^�' . Requester: Phone No: Imo' Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 41)A744 Date /61 J /' n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. )0\ () INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: T i 661r. Plzwreas Type of Inspection: m. 410b. 6YKvni Address: '1r//AeN PA -Kt e Date Called: Special Instructions: Utir,r /00 Date Wanted/a.m., VS//6 p.m. RequesteVV 1)0Z6 --g Phone No: 206-7/ - 32-C" Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: 4) Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit 1' -ao73 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Pr ect: Dlaur A/ Setl Ty a of Inspection: _____ a t/6- I /VS (4-4771A Address: Zxr✓te PAi X E Date Iled: Special Instructions: Date Want 2 A 6, .,1.......,n: Requester. Phone No: Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Inspector: Date: e/21/0 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 11j& -0073 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Prpiect: ���c �� Type of Inspection: W tL lvsvL'd Address: ?CAT/WW1/1V 9ArtK. E Date Called: Special Instructions: Date Wanted: g/Z//(s p.m. Requester: ` Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: Inspector: Date: 0/2M REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 4 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION b16-60-73 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Pr`oiect: Jim p%tl `Is Tye of Inspection: adoaZ % ' SLA. Address: _ O f^ jlam.o w'L P-gil_ r Date Called: Special Instructions: ' Ai r.iere, Date Wantd:: , a.m. Requester:/ Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: Af Inspector:,4 Date 2 /6 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 ot173 Project: bICCtir P,t /Jm eS Type of spection: liw1,j6- Address: 34/& /-4 knote P Date Called: Special Instructions: LM. it i°0 Ti ft Lt�o7 (4J�yS CAJC( 7 Date Wanted: %a.r g ////G p.m. / Requester: Phone No: EiApproved per applicable codes. Corrections required prior to approval. COMMENTS: n/a /406/vroti_ Cel tJ �i/(L Date / / 6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit b/6 _pO'13 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: Type of inspection: Address: 3zis—Autieviv PA>2K G Date Called: Special Instructions: INA-1.1 UNir /� 7 Date Wanted: u�l� a..m p Requester: bOtek Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 2 fiZ , may AerA iw c_ Pay r�2 Inspector: Date: 7/26//‘ 6 /‘ REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. idIIRetain a copy with permit INSPECTION RECORD " PECTION NO. PERMIT NO. Pi!- Q)73 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 rc Proi ( Pil TyQe of Inspection: Acdress: 3L itilaOieir 'ar r-- E c ate Called: • to 0 Special Instructions: �` I tiA-c, LUA-(f ,1 ��s Date Wanted:+ 6 --z--1 - /,6 a.m. p.m. R.134 g i c Ph � 7 ( q , 354 pproved per applicable codes. Corrections required prior to approval. OMMENTS: P// Inspector: Dater n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit ( - Y) PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:Type Sprinklers: of Inspection: Address: /-PC Contact "Person: Suite #: 5 ys Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: — , e 'ten-- 7-s, 1 ''-- Abe-, 72 -- tir5n Occupancy Type: - //1/5.7// il// (/`-1 5-77/4 /'AJo- .'),) ,-- /Pl/�t ."t./, Ceiv e r ar C �, STS, -/T -fret � (- ,„/a�+/ ,moi ,--r i ,470,,,,,,f -c. # K3 7 / _TfG 9D/. V -- .411 ,..7/6 ,va„-. f ei�-t-{4,/g 7Z//4 --t �vd/S 1/�✓ .s7�i'.7,_ -t yr -i( / fre7/1 / Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector`: TA- '(, 5 Date: 5y -z J, co Hrs.: /. U $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D) 7 - O 73 /L-- /L/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project: .e Cc{* 0,"10-t-ei S Type.,.of Inspection: 5() /-f (ko f CCu-er- Address: 3 c/S— Suite #: /4 p g- Contact Person: Special Instructions: Occupancy Type: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: / 4b -D %.c11/4c-. —to /4 f i,1} //,.-' a ,4 04 0 V -Q L --_--i-4,12 0.0� /1i & (.Uf -P� 3 . , ) 7 ----;(D �( / v r 6( nJ {1 C- !c -G. /1 - Cr to D. e__ A, i r 0 51AQ/4- c,,o,5L oloo 9a5--- IA» d -_S'--- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: iik/.\ c C Z Date: 94 a/4, Hrs.: a $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Interior Lighting Summary LGT-SUM 2C42 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Dec 2013 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write- protected. Project Address 345 Andover Park East Date 1/1/14 Tukwila, WA For DPD Use __ ": LH Applicant Name: Alene Torossian - Broderick Architects 1 G. ('`j VJ Applicant Address: 55 South Atlantic Street, Suite 301, Seattle, WA Applicant Phone: 206.682.7525 Project Description ['New Building ❑Addition ®Alteration Plans Included Lighting Compliance Path Oighting Power Density Calculations Orotal Building Performance (If Total Building Performance then only LGT-CHK is required.) Lighting Power Allowance Method Selection required to enable LPA forms C Building Area Method pace -By -Space Method — Interior Lighting System Description Briefly describe lighting system type and features. _ _ !-!t• —, CODE COMPLIANCE . APPROVED =; I MAY 0 5 2016 Cit! Oft Tukwila BUILDING DIVISION Additions and Change of Space Use (C101.4.3 & C101.4.4) Addition area or Change of Space Use area complies with all applicable provisions as stand alone project is combined with existing building lighting systems to demonstrate compliance with all applicable C101.4.3 Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and existing if applicable) lighting wattage of Addition or Change of Use space. Provide applicable lighting controls per C405.2 and of lighting controls per C405.13. ddition area rovisions per Provide Building proposed (including commissioning Alterations, Renovations and Repairs (C101.4.3.1) 1,0% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed wattage within the lighting retrofit space in Maximum Allowed Wattage table and proposed (including existing) lighting wattage in Proposed Wattage table. Retrofit and non -retrofit spaces shall be documented separately using multiple forms. Less than 20% of luminaires in space replaced Provide a separate Space -By -Space Method (LTG -INT -SPACE) Compliance Form for this retrofit area. Document existing total wattage within the lighting retrofit space in cell provided in the Maximum Allowed Wattage table. Document proposed (including existing) lighting wattage in the Proposed Wattage table. Damp and/or ballast replacement within existing luminaires only — existing total interior building wattage not increased Dew wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone controls (C405.2.2.3), specific application controls (C405.2.3), and commissioning of lighting controls per C405.13 Dew or moved lighting panel Provide all applicable lighting controls as noted for New Wring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. pace is reconfigured - luminaires unchanged or moved only Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. p P c F iv F n Do changes are being made to the interior lighting and space use not changed. CITY OF TU KSI N(OO73 MAR 212016 A PERMIT CENTER Interior Lighting Summary - Space -By -Space LTG -INT -SPACE 201'2 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Dec 2013 Project Address 345 Andover Park East Date 1/1/14 Lighting Alterations, Renovations & Building Additions CLess than 20% of C 20% or more of C Stand alone C Addition combined fixtures replaced fixtures replaced bldg. addition w/exist Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Space Types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 20% of existing fixtures will be replaced, provide total existing lighting wattage (prior to retrofit) in the space provided in the Maximum Allowed Lighting table. For DPD Use Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) 100 LOBBY Lobby 0.90 706 635 101 ADMIN Office - Open plan 0.98 101 99 102 STORAGE Storage 0.63 36 23 103 RESTROOM Restroom 0.98 68 67 104STOREGE Storage 0.63 26 16 105 RESTROOM Restroom 0.98 80 78 106 RESTROOM Restroom 0.98 47 46 107 CONFERENCE ROOM Conference/meeting/multipurpose 1.23 232 285 108 BREAK Dining area: Family dining area 0.89 241 214 109 OFFICE Office - Enclosed 1.11 427 474 110 OFFICE Office - Enclosed 1.11 189 210 111 OFFICE Office - Enclosed 1.11 122 135 112 STORAGE Storage 0.63 42 26 113 OFFICE Office - Enclosed 1.11 255 283 114 OFFICE Office - Enclosed 1.11 174 193 115 OFFICE Office - Enclosed 1.11 124 138 116 EQUIPMENT ROOM Manufacturing: Equipment room 0.95 496 471 117 OFFICE Office - Enclosed 1.11 185 205 118 OPEN Workshop 1.59 1411 2243 119 OPEN Workshop 1.59 262 417 120 OPEN Workshop 1.59 1450 2306 121 OPEN Workshop 1.59 323 514 122 STORAGE Storage 0.63 190 120 123 OPEN Workshop 1.59 690 1097 A num"* Entter Heights rExisting LTightir ter x'istttitts: #Retail #splay Aliowance from GTrI— N' TSN -SPLAY * Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height. Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Provosed Lightin>r Wattat=_e Total Area Allowed Watts 7877 10296 Location (plan #, room #, or ALL) Fixture Description*** Number of Fixtures Watts/ Fixture Watts Proposed 101 Pendant indirect / direct 4 120 480 102 Pendant indirect / direct 1 120 120 103 Recessed Can 2 120 240 104 Pendant indirect / direct 1 120 120 105 Recessed Can 2 120 240 106 Recessed Can 1 120 120 1072 x 4 recessed troffer 4 69 276 1082 x 4 recessed troffer 4 69 276 • 1092 x 4 recessed troffer 8 69 552 110 2 x 4 recessed troffer 4 69 276 111 2 x 4 recessed troffer 2 69 138 1122 x 4 recessed troffer 1 69 69 1132 x 4 recessed troffer 6 69 414 114 2 x 4 recessed troffer 3 69 207 115 2 x 4 recessed troffer 2 69 138 1162 x 4 recessed troffer 6 69 414 1172 x 4 recessed troffer 4 69 276 118 Pendant indirect/direct 17 120 2040 119 Pendant indirect / direct 5 120 600 120 Pendant indirect / direct 7 120 840 121 Pendant indirect / direct 7 120 840 122 Pendant indirect/direct 4 120 480 123 Pendant indirect/direct 7 120 840 123 Wall Valence 2 120 240 Retail Display Lighting from LGT-INT DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 10236 *** Include existing to remain lighting fixtures and exempt lighting equipment per notes below. Notes: 1. Include ALL proposed lighting fixtures. 2. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 3. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices of the transformer. For low voltage track lighting list the transformer rated wattage. 4. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 5. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. 6. If #NA appears in Retail Display cells, information on LTG -INT -DISPLAY is incomplete. Interior Lighting Power Allowance COMPLIES Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 201 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Dec 2013 Project Info Project Address 345 Andover Park East Date 1/1/14 Tukwila, WA For DPD Use Applicant Name: Alene Torossian - Broderick Architects Maximum Allowed Display Lighting Wattage Location (plan #, room #, or ALL) Retail Display Area Type* Allowed Watts per ft2 ** Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) * Only retail sales areas that meet the requirements defined in Table C405.5.2(2) footnote A may be entered here. Select retail sales areas form drop down menu. ** Wattages per Table C405.5.2(2) footnote A. ++ Display light allowance per footnote A calculation. Total Display Lighting Base Allowance ++ Total Display Allowance Area Area Watts Proposed Display Lighting Wattage Only separately controlled display fixtures .ndependent of general area lighting per Table C405.5.2(2) footnote A may be entered here. Display Area* Location (plan #, room #, or ALL) Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed * Select retail sales display area from drop down menu. Proposed Display Lighting Totals Retail 1 Total Proposed Watts Retail 2 Retail 3 Retail 4 Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturers listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. Interior Lighting Summary - Building Area Method LTG -INT -BLD 201'2 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Dec 2013 Project Address 345 Andover Park East Date 1/1/14 Lighting Alterations, Renovations & Building Additions CLess than 20% of ai 20% or more of C Stand alone Addition combined fixtures replaced . fixtures replaced bldg. addition w/exist Notes: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing bldg lighting to demonstrate compliance. Refer to C101.4.3. b. For retrofits and building additions, provide Building Area types and gross interior areas in the Maximum Allowed Lighting table. If a builidng addition will comply as combined with the overall existing builidng, include all applicable existing Building Area types and gross interior areas. c. Document new fixtures and all existing to remain fixtures in the Proposed Lighting table. d. If less than 20% of existing fixtures will be replaced, use LTG -INT -SPACE form. For DPD Use Space -By -Space method selected. Use LTG -INT -SPACE form. Building Area* Location (plan #, room #, or ALL) Area Description Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) * Select Table C405.5.2(1) Building Area from drop down menu. Total Space -By -Space method selected. Use LTG -INT -SPACE form. Building Area* Location (plan #, room #, or ALL) Fixture Description** Number of Fixtures Watts/ Fixture Watts Proposed * Select Table C405.5.2(1) Building Area from drop down menu. ** Include existing to remain lighting and exempt lighting equipment per notes below. Comvliance by Building Area Building Area Warnings Total Allowed Watts Total Proposed Watts Interior Lighting Power Allowance Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Area type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL proposed lighting fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 6. Document existing to remain fixtures in Proposed Lighting table in the same manner as new fixtures. Identify as existing in fixture description. Exterior Lighting Summary 2012 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 LTG -EXT Revised Dec 2013 Project Info Project Address: 345 Andover Park East Date 1/1/14 Tukwila, WA For DPD Use Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) J 'B2,1- Applicant Name: Alene Torossian - Broderick Architects le Applicant Addr: 55 South Atlantic Street, Suite 301, Seattle, WA Applicant Phone: 206.682.7525 Project Description C New Building C Addition 12 Alteration Flans Included Lighting Zone As specified by jurisdiction. Zone selection required to enable LTG -EXT form C Zone 1 C Zone 2 C Zone 3 Compliance Option C Lighting Power Density Calculations C Total Building Performance Building Grounds Applies to luminaires > 100 Watts E Efficacy > 60 lumens/W E( Controlled by motion sensor C Exemption (list) Exterior Lighting Alterations No changes are being made to the existing exterior lighting CNew wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable exterior lighting controls per C405.2.4 and commissioning per C408.3 Tradable Maximum Allowed Lighting Wattage Base Site Allowance: Tradable Surfaces Surface Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x It) Total Allowed Tradable Watts: Tradable Proposed Lighting Wattage (Use mfgrlisted maximum input wattage for luminaire.) Tradable Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) REVIEWED FOR le £! mnIi�►�i[ r crriF cQWpuANCE i Total proposed tradable watts may not exceed the sum of total allowed tradable watts Total Proposed Tradable Watts: —11,............ A..... 1,........... amu.. nu.,,.,.n.,..e .,..r neollor4 r., m,Ln trrrInhln watts comply can be applied to individual non -tradable categories. Non -Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: 0 Non -Tradable Surfaces Surface Descript __ -. _ .---,_^ Allowed Watts ar zre If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) REVIEWED FOR le £! mnIi�►�i[ r crriF cQWpuANCE i I Br pt OVEt f -Tradable Proposed Lighting Wattage Non -Tradable Surface MAY 0 Fixture Descrip ion i Lumber of Fixtures Watts/ Fixture Watts Proposed City of'rc�w� le £! mnIi�►�i[ r nivrPEJICIE Non -tradable proposed watts may not exceed allowed watts for ani# - - excess Non -Tradable watts: unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Site Allowance Balance: 0 0 Exterior Lighting bwoo73 RECEIVED CITY OF TUKWILA MAR 212016 PERMIT CENTER ighting, Motor, and Transformer Permit Documents Checklist LTG -CHK 2012 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Dec 2013 Project Address 345 Andover Park East Date 1/1/14 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Seattle Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents DPD Notes LIGHTING CONTROLS (Section C405.2) C405.2.1.1 C405.2.1.2 Manual interior lighting controls Indicate on plans the manual control type & locations served; Indicate of plans the 50% lighting load reduction method provided or identify exception taken C405.2.2.1 Automatic time switch controls and override switching Indicate lighting system automatic shut-off capability - identify lighting zone areas served on plans; Indicate locations of override switches on plans and the areas served, include area sq. ft.; Note 2500 sq. ft. max area on one override switch; Indicate locations where automatic shutoff is provided by other methods (occupancy sensor, daylight controls, etc) C405.2.2.2 Occupancy sensors Indicate on plans the locations served by occupancy sensors; Note 15 -minute setting C405.2.2.3 Daylight zones - Vertical fenestration and skylights Indicate vertical fenestration primary and secondary daylight zone areas on plans, include sq. ft. & lineal feet of facade; Indicate skylight daylight zone areas on plans, include sq. ft. & lineal feet of facade C405.2.2.3.2 Daylight zone controls Indicate on plans the locations served by daylight zone controls; Indicate in plans the lighting load reduction (dimming) method - stepped or continuous dimming C405.2.3 Specific application lighting controls - General Indicate on plans the locations served by specific application lighting controls C405.2.3 - Items 1&2 Display and accent lighting Indicate lighting control method for display and accent lighting, and display case lighting; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space C405.2.3 - Item 3 Hotel/motel guest rooms Provide a lighting control device at each guest room entry for all permanently installed fixtures in guest room; Indicated whether lighting control is manual or automatic C405.2.3 - Item 4 Supplemental task lighting Provide automatic shut-off vacancy controls for supplemental task lighting, including under -shelf or under -cabinet lighting C405.2.3 - Item 5 Lighting for non -visual applications Identify eligible non -visual applications and method of lighting control; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space C405.2.3 - Item 6 Lighting equipment for sale or demonstration Indicate lighting control method for lighting equipment for sale or demonstration; Indicate these fixtures are controlled independently from both general area lighting and other lighting applications within the same space C405.2.3 - Item.7 Means of egress lighting If egress lighting power density is greater than 0.05W/ft2, indicate method of automatic shut-off during unoccupied periods; Identify on plans the egress fixtures that function as both normal and emergency means of egress illumination C405.2.3 - Item 8 Stair lighting g g Indicate occupancy sensor lighting P Y 9 9 power reduction control C405.2.3 - Item 9 Parking garage lighting Indicate occupancy sensor lighting power reduction control and size of area controlled C405.10 C405.11 Cooler and freezer lighting Provide vacancy device or timer to turn off fixtures within 15 minutes of unoccupancy for cooler and freezer lighting fixtures with lamp efficacy less than 40 lumens per watt C405.2.4 Exterior lighting controls Indicate on exterior lighting plans the automatic lighting control method and locations served. Indicate required information separately for facade lighting and other exterior lighting C405.6.1 Exterior building grounds lighting controls Provide motion sensor controls for building grounds fixtures rated at greater than 100 watts with lamp efficacy less than 60 lumens, or identify exception taken C408.3 Lighting system functional testing Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response; Identify in construction documents the party responsible for functional testing of automatic lighting controls INTERIOR LIGHTING POWER & EFFICACY (Sections C405.5, C405.10, C405.11) C405.5.1 C405.5.1.1 rnnF e ',Total connected Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; Identify spaces eligible for lighting power exemption on plans and in compliance forms; Lighting, Motor, and Transformer Permit Documents Checklist LTG-CHK 2012 Seattle Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and all R1 Revised Dec 2013 Project Address 345 Andover Park East Date 1/1/14 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the Seattle Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents DPD Notes ''''''J. I.G C405.5.1.3 C405.5.1.4 interior lighting power Identify lighting equipment eli ible for exemption in fixture schedule and in compliance forms; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently C405.4 Exit signs Provide exit sign types and rated watts per fixture in fixture schedule (maximum 5 watts per fixture) C405.10 C405.11 Cooler and freezer lighting For lighting in walk-in coolers and freezers, and refrigerated warehouse coolers and freezers, provide rated lamp efficacy (in lumens per watt) in fixture schedule Lighting Power Calculation - Indicate compliance path taken C405.5.2 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans C405.5.2 Space-By-Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas as applicable EXTERIOR LIGHTING POWER_& EFFICACY (Section C405.6) C405.6.2 Total connected exterior lighting power Provide fixture schedule with fixture types, lamps, ballasts, and rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting Table C405.6.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ C405.6.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts, provide rated lamp efficacy (in lumens per watt) in fixture schedule C405.6.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed C405.6.3 Full cutoff luminaires Indicate full cutoff luminaires for outdoor fixtures taller than 15 feet above ground MOTORS & TRANSFORMERS (Sections C405.8, C405.9) C405.8 Electric Motors For motors not part of an HVAC system, provide electric motor schedule on electrical plans with hp, rpm, and rated efficiency C405.9 Transformers Provide distribution transformer schedule on electrical plans with transformer size and efficiency C405.14 Controlled receptacles Indicate that at least 50% of office and classroom receptacles are controlled by occupancy sensor or time clock. Indicate A2olocation and area served by each override switch If "no" is selected for any question, provide explanation: April 05, 2016 City of Tukwila Department of Community Development ALENE TOROSSIAN 55 S ATLANTIC ST SUITE 301 SEATTLE, WA 98134 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D16-0073 DIECUT PRINTERS - 345 ANDOVER PARK E SUITE 120 Dear ALENE TOROSSIAN, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: PW DEPARTMENT: Joanna Spencer at 206-431-2440 if you have questions regarding these comments. • 1) Applicant shall fill out King County Non -Residential Sewer Use Certificate form and list all the new plumbing fixtures units to be installed. Please do not include any fixtures that will be replaced in kind. • 2) The building needs to have backflows on the domestic and fire prevention line installed. A separate backflow deficiency letter was mailed to SRO Properties, Inc, property owner.Backflows can be installed under a revision to Die Cut Printers TI, or under a separate Public Works permit or delayed for 90 days by posting a bond. • 3) Based on Public Works inspection of the existing 4 storm drainage catch basins it was determined that all of them had excess sediment and need sediment/gravel removal and cleaning. The CB east of the loading dock needs to be sealed and re -grouted, since gravel was accumulating on the bottom. Please show location of these CBs on your site plan. Storm drainage permit activity will be added to your permit. • 4) A licensed electrician shall inspect the existing sump pump inside the catch basin located in front of the loading dock. Inspection results shall be submitted in writing addressing if the pump is wired up to code and is in working order. Otherwise applicant shall obtain a separate Tukwila Electrical permit to rewire and/or replace the sump pump. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206)431-3655. Sincerely, Bill Rambo Permit Technician File No. D16-0073 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Joanna Spencer From: Sent: To: Subject: Joanna Spencer Wednesday, March 23, 2016 8:47 AM Todd Reedy RE: Direct Printers 11 @ 345 APE -Suite 120 D16-0073 Thank you Todd. PW will require the PIV to be relocated to the back of the sidewalk. From: Todd Reedy Sent: Wednesday, March 23, 2016 7:57 AM To: Joanna Spencer Subject: RE: Direct Printers TI @ 345 APE -Suite 120 D16-0073 Hello Joanna, This is what I reported in 2012 for 345 APE when they had applied for a permit and conditions are still the same: 345 APE 10/11/12 Here's the scoop on 345 APE: -No RPPA on 1.5" domestic service for premise isolation. - There is an 8" fireline connection that we do not have any records of a testable backflow preventer installed on. There is no vault outside the building and I cannot get access to the inside to see what type of backflow prevention is installed. Most likely it is just a single check valve. Another issue is that the PIV is in the middle of the sidewalk, creating a hazard. I'm not sure if that issue can be addressed on a 11 permit. - They need to install a Storz adapter on the FDC that is on the southeast wall of building. I recently met Mike Cusick at that property and we confirmed that the backflow preventer on the fireline is just a single check valve on the riser inside the building. Todd From: Joanna Spencer Sent: Monday, March 21, 2016 5:05 PM To: Todd Reedy <Todd.Reedy@TukwilaWA.gov> Cc: David McPherson <David.McPherson(a@TukwilaWA.gov>; Joanna Spencer <Joanna.Spencer@TukwilaWA.gov> Subject: Direct Printers TI @ 345 APE -Suite 120 D16-0073 Good Afternoon Todd, Are their backflows up to date? Joanna PERMANENT FILE COPY 016-0013 Joanna Spencer From: Kevin Broderick <kevin@broderickarchitects.com> Sent: Tuesday, March 22, 2016 2:20 PM To: Joanna Spencer Cc: Alene Torossian Subject: Re: Diecut Printers TI @ 345 APE, Tukwila D16-0073 Hi Joanne, DIECUT Printers manufactures custom vinyl stickers using ink jet and digital plotters and die cut machines. The print out designs on large sheets of material with a peel and stick backing and the diecut them to the desired shape. The ink jet plotters are similar to the ones we use here in our architectural office, it's printing but not your typical printing press with a "printing press". Here is a link to their website: http://diecutstickers.com/digitaldiecutstickers/ I hope this helps, please feel free to call if you have further questions. Thank you, Kevin Kevin J. Broderick AIA, Principal BRODERICK ARCHITECTS 55 S. Atlantic St, Suite #301 Seattle, WA 98134 206.682.7525 www.broderickarchitects.com Attached Electronic Files Disclaimer: These electronic files are intended expressly to facilitate the work of the original recipient. Broderick Architects makes no warranty as to the accuracy or validity of these drawings, which remain the copyrighted intellectual property of Broderick Architects. Under no circumstances shall these electronic files be transferred to any other party without the express written permission of Broderick Architects. Use of these drawings implies agreement to the above conditions. On Mar 22, 2016, at 2:05 PM, Joanna Spencer <Joanna.Spencer@TukwilaWA.gov> wrote: Kevin, Could you please provide us a brief description of the DIECUT Printers business. Will they do any printing at this location? Joanna Spencer Development Engineer Public Works Department 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188-2544 Phone: 206 431-2440 Fax: 206 431-3665 PERMANENT FILE COPY 1 DIG EP 0073 SRO Properties, Inc. March 24, 2016 Page 2 The Post Indicator Valve (PIV) is in the middle of the sidewalk creating a hazard, and it needs to be moved either to the back of the sidewalk or to the parking lot. Storz adapters need to be installed on the Fire Department Connection (FDC) that is mounted on the southeast wall of the building. Please note that plans for the fire protection backflow retrofit design must be stamped, signed and dated by a Level III certificate of competency holder or by a professional engineer. If you need assistance to locate these backflows in the field, please contact Mr. Todd Reedy, Tukwila Water Department, directly at (206) 571-6309. The Public Works Director will withhold issuance of the Diecut Printers Tenant Improvement permit D16-0073 until the Permit Center receives a revision to this TI permit application or a separate Public Works Type C Construction permit that includes plans for RPPA and DDCVA installation, together with a construction cost estimate for items a) and b). When submitting for a Type C permit, Public Works collects a base application fee and plan review and ($250.00 plus 2.5% of construction cost for RPPA and DDCVA installation and backflow testing). An additional 2.5% of subject construction cost will be paid at the time of permit issuance. Applicant also has an option to post a bond for these backflow installations in the amount equal to 150% of the design, installation and testing cost of the subject backflows, together with a letter confirming the installation within no more than 90 days. I have enclosed Public Works Bulletin C5 to help you. Please call Mr. Mike Cusick, P.E., Public Works Senior Water and Sewer Engineer, at (206) 431-2441 if you have any questions. Sincerely, JannaSpencer Development Engineer J S:Iw enclosures: Public Works Bulletins #A1, A2, C5 Public Works Permit Application cc: D16-0073 File Mike Cusick, Senior Water and Sewer Engineer Todd Reedy, Water Department Kevin Broderick Daniel Diederichs (W:PW Eng/Other/Joanna Spencer/Letter SRO Properties 032416) City of Tukwila Allan Ekberg, Mayor Public Works Department - Bob Giberson, Director March 24, 2016 SRO Properties, Inc. 1411 4th Avenue, #1315 Seattle, WA 98101 RE: Diecut Printers Tenant Improvement 345 Andover Park East, Tukwila Permit Number: D16-0073 To Whom It May Concern: PERMANENT FILE COPY In accordance with Washington State Department of Health guidelines for Group A Public Water Systems, Public Works has implemented a cross -connection control program to protect the public water system from contamination via cross -connection. Since the project included alterations to the existing plumbing system, the entire plumbing system must be brought up to the current standards as set forth in the Uniform Plumbing Code including installation of an approved backflow prevention on the domestic, fire prevention and irrigation water supply lines to the building. The program requires elimination or control of any cross -connection between the distribution system and a consumer's water system by the installation of an approved backflow device. The City has determined that the building at the above address has deficiencies on the domestic water and fire prevention lines. a) Domestic Water A Reduced Pressure Principle Assembly (RPPA), previously called a Reduced Pressure Backflow Assembly (RPBA), shall be installed immediately downstream of the permanent 1.5" water meter. The RPPA shall be installed in a Hot Box/Rock or equal freeze protection enclosure. On your site plan show the property lines, location of the domestic water meter and proposed RPPA location. Call out size/manufacturer/model number of the proposed RPPA and submit a backflow cut sheet. b) Fire Prevention The fire backflow prevention device located inside the building is a single check valve on the riser inside the building which is a non -testable device and doesn't meet the current code. It needs to be replaced by a WA State Department of Health approved Detector Double Check Valve Assembly (DDCVA) 6300 Building • 6300 Southcenter Boulevard Suite 100 • Tukwila, WA 98188 • 206-433-0179 Tukwila City Hall • 6200 Southcenter Boulevard • Tukwila, WA 98188 • 206-433-1800 • Website: TukwilaWA.gov PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0073 PROJECT NAME: DIECUT PRINTERS DATE: 04/19/16 SITE ADDRESS: 345 ANDOVER PARK E - SUITE 120 Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building Division Public Works Fire Prevention Structural n Planning Division Permit Coordinator m PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 04/21/16 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Approved with Conditions Denied (ie: Zoning Issues) DUE DATE: 05/19/16 cal/ n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D16-0073 DATE: 03/21/16 PROJECT NAME: DIECUT PRINTERS SITE ADDRESS: 345 ANDOVER PARK E - SUITE 120 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: PNU'G Building Division ,� Core- 3^� Public Works1111 Aux, 1--)q--tfr to Fire Prevention Structural n t/1'- ��- Planning Division Fil Permit Coordinator w PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 03/22/16 Structural Review Required REVI:EWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required DUE DATE: 04/19/16 Approved with Conditions n Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only rn CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping 0 PW Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: htip://wtvts'.ci.tulnvila.wn.us REVISION SUBMITTAL Revision submittals trust be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: April 19, 2016 Plan Check/Permit Number: D16-0073 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building inspector or Plans Examiner Project Name: Diecut Printers Project Address: 345 Andover Park E — Suite 120 Contact Person: Kevin Broderick Phone Number: 206.682.7525 Summary of Revision: Please note all the Public works will be a differed submittal to the city. Public works will be under a separate permit and not a part of the Tenant Improvement. RECEIVED CITY OF TUKWILA APR 19 2016 PERMIT CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila jPermit Center by: -Entered in "I'RAKiT on l" •-(co \applications\fornis-applications on 1ine\revision submittal Created: 8-13-2004 Revised: SEATTLE CONST RESOURCES TlTC Home Espanol Contact Safety & Health Claims & Insurance ilk Washington State Department of �.. Labor & industries Page 1 of 2 Search L&I A -Z. Index Help My I.,&I Workplace Rights Trades & Licensing SEATTLE CONST RESOURCES INC Owner or tradesperson Principals SLOATE, CORY MICHAEL, PRESIDENT HOMAN, ANTHONY D, VICE PRESIDENT SLOATE, SCOTT J, SECRETARY SOWELL, RHETT C, VICE PRESIDENT (End: 01/10/2014) SLOATE, MICHAEL J, PRESIDENT (End: 01/27/2014) Doing business as SEATTLE CONST RESOURCES INC WA UBI No. 601 187 901 1414 ELLIOTT AVE W SEATTLE, WA 98119 206-282-7500 KING County Business type Corporation Governing persons ANTHONY HOMAN CORY SLOATE; SCOTT SLOATE; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. SEATTCR101 BZ Effective — expiration 01/09/1990— 02/05/2018 Bond ................. Lexon Ins Co Bond account no. 9804860 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 03/08/2011 03/01/2011 Expiration date Until Canceled Bond history Insurance ............................ Liberty Northwest Ins Corp Policy no. 53450517 $1,000,000.00 Received by L&I Effective date r\%us-oql 7oor https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601187901&LIC=SEATTCR101BZ&SAW= 5/11/2016 ting. Copyright m Thursday, March 17, 2016 by Broderick Architects, pile ect or for completion of this project by others except by prior arrangeme This document represents a proprietary design owned by the architect and shall not be used on other projects or additions to this pr GENERAL NOTES 1. ALL GENERAL NOTES GIVEN HEREIN APPLY TO ALL ALLIED TRADES FOR THE PROJECT AMENDED ELSEWHERE TO INCLUDE ISOLATED CONDITIONS 2. THE DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN AND EXTENT OF THE WORK AND ARE PARTLY DIAGRAMMATIC THEY ARE NOT INTENDED TO BE SCALED. 3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. 4. THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY ALL GRADES, LINES, LEVELS, CONDITIONS, AND DIMENSIONS AT THE JOB SITE AND A5 SHOWN ON THE DRAWINGS. THEY SHALL REPORT ANY ERROR5 OR INCONSISTENCIES IN THE ABOVE TO THE ARCHITECT BEFORE COMMENCING WORK. 5. CONTRACTOR AND SUBCONTRACTORS SHALL OUT THEIR WORK FROM ESTABLISHED REFERENCE POINTS AND BE RESPONSIBLE FOR ALL LIINES, ELEVATIONS AND MEASUREMENTS IN CONNECTION WITH THEIR OWN. 6. PROTECTION: A. THE CONTRACTOR IS RESPONSIBLE AND SHALL COMPLY WITH THE REQUIREMENTS OF THE BUILDING CODE HAVING JURISDICTION AND ALL LOCAL,STATE, AND FEDERAL LAWS. B. PROVIDE ALL SHORING AND BRACING AS REQUIRED FOR THE PROPER EXECUTION OF THE WORK. REMOVE WHEN WORK I5 COMPLETED. C. PROVIDE AND MAINTAIN GUARD LIGHTS AND BARRICADES AT ALL AREAS OF WORK ADJACENT TO PUBLIC WAYS OR PUBLIC SPACES. D. AT ALL TIMES PROVIDE PROTECTION AGAINST WEATHER (RAIN, WIND, STORMS, OR HEAT) 50 AS TO MAINTAIN ALL WORK, MATERIALS, APPARATUS AND FIXTURES FREE FROM DAMAGE. E. THE CONTRACTOR SHALL PAY FOR ALL DAMAGES TO ADJACENT STRUCTURES, SIDEWALKS AND TO STREETS OR OTHER PUBLIC PROPERTY OR TO ANY PUBLIC UTILITIES. 7. CONTRACTOR AGREES THAT HE WILL HOLD THE OWNER, ARCHITECT AND/OR ANY OF THEIR EMPLOYEES OR AGENTS HARMLESS FROM ANY AND ALL DAMAGE CLAIMS WHICH MAY ARISE BY REASON OF ANY NEGLIGENCE ON PART OF THE CONTRACTOR, ANY OF HIS SUBCONTRACTORS AND/OR SUBCONTRACTOR'S MATERIALS AND EQUIPMENT SUPPLIERS AND/OR ANY OF THEIR EMPLOYEES OR AGENTS, IN PERFORMANCE OF THIS CONTRACT; AND IN CASE ANY ACTION IS BROUGHT BEFORE THEREOF AGAINST THE OWNER, ARCHITECT AND/ OR ANY OF THEIR EMPLOYEES OR AGENTS, CONTRACTOR SHALL ASSUME FULL RESPONSIBILITY FOR DEFENSE THEREOF, AND UPON HIS FAILURE TO DO 60 ON PROPER NOTICE, OWNER, ARCHITECT ANP/OR ANY OF THEIR EMPLOYEES OR AGENTS RESERVE THE RIGHT TO DEFEND SUCH ACTION AND CHARGE ALL COSTS THEREOF TO CONTRACTOR. 8. IF ANY ERROR5 OR OMISSIONS APPEAR IN THE DRAWINGS, SPECIFICATIONS OR OTHER DOCUMENTS, THE CONTRACTOR SHALL NOTIFY THE ARCHITECT IN WRITING OF SUCH OMISSIONS OR ERRORS PRIOR TO PROCEEDING WITH ANY WORK WHICH APPEARS IN QUESTION. IN THE EVENT OF THE CONTRACTOR'S FAILING TO GIVE SUCH NOTICE, HE SHALL BE HELD RESPONSIBLE FOR THE RESULTS OF ANY SUCH ERRORS OR OMISSIONS AND THE COST OF RECTIFYING THE SAME. THE CONTRACTOR SHALL HAVE ALL ITEMS OR DETAILS CLARIFIED WITH THE ARCHITECT PRIOR TO SUBMITTING A BID; OTHERWISE THE ARCHITECT'S INTERPRETATION SHALL BE FINAL. 9. THE CONTRACTOR SHALL USE THE STRUCTURAL DRAWINGS TOGETHER WITH THE ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAWINGS TO LOCATE DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, OPENINGS, REGLETS, BOLT SETTING, SLEEVES, DIMENSIONS, ETC. POTENTIAL CONFLICTS SHALL BE TRANSMITTED TO THE ARCHITECT BEFORE PROCEEDING WITH THE WORK. 10. ALL WOOD WALL DIMENSIONS GIVEN ARE TO EXTERIOR FACE OF FRAMING. LIGHT GA STEEL WALLS ARE DIMENSIONED TO CL OF FRAMING. 11. SOME CONNECTIONS INDICATED ON THE DRAWINGS ARE SCHEMATIC. SECURE ALL COMPONENTS RIGIDLY TO STRUCTURE AND EACH OTHER. USE FASTENERS DESIGNED FOR EACH INSERVICE CONNECTION. 12. OBTAIN CLARIFICATION AND INTERPRETATION OF DRAWINGS AND SPECIFICATIONS. INCLUDE ADDITIONAL DETAIL, DIRECTLY FROM ARCHITECT. 13. WASTE MATERIAL AND RUBBISH FROM DEMOLITION AND ALTERATION OPERATIONS SHALL BE REMOVED FROM SITE AS RAPIDLY AS POSSIBLE AND SHALL NOT BE ALLOWED TO ACCUMULATE ON PREMISES. DISPOSAL OF MATERIALS WILL BE AT THE DISCRETION OF THE CONTRACTOR. OPEN FIRES WILL NOT BE PERMITTED FOR DISPOSAL OF WASTE. CONTRACTOR SHALL PROVIDE AN EXTERIOR AREA TO COLLECT ALL DEMOLISHED NOT TO BE REUSED. THIS AREA SHALL BE SAFE AND UN -OBSTRUCTING THE BUILDING FUNCTION AND THE OWNER'S DAILY BUSINESS OPERATIONS. 14. EXISTING UTILITY LINES INDICATED OR NOTED ON THE DRAWINGS ARE SHOWN A5 OBTAINED FROM EXISTING INFORMATION AND ARE PROBABLY INCOMPLETE AND ONLY APPROXIMATE IN LOCATION. THE CONTRACTOR SHALL TAKE EXTREME CAUTION TO AVOID DAMAGE TO EXISTING UTILITY LINES AND/OR HARM TO PERSONNEL ENGAGED IN WORKING IN THE AREA. ABBREVIATIONS AT & AND 0 DEGREE O DIAMETER # POUNDS AB ANCHOR BOLT ABV ABOVE ACT ACOUSTICAL TILE A/E ARCHITECT / ENGINEER AFF ABOVE FINISH FLOOR ALUM ALUMINUM ALT ALTERNATE ANSI AMERICAN NATIONAL STANDARD INSTITUTE ARCH ARCHITECT OR ARCHITECTURAL BD BLK'G BLDG BM BTU BUR CB CJ CL CLG CLR CMU CO COL CONF CONC CONT COORD CPT CT CW DBL DEG DEMO DF DIAM DIAG DIM DN DG DTL D5 DW (E) EA EIFS ELECT EXT ELEV EQUIP EQ EW EXIST FD FDN FEC BOARD BLOCKING BUILDING BEAM BRITISH THERMAL UNIT BUILT UP ROOF CATCH BASIN CONSTRUCTION JOINT CENTER LINE CEILING CLEAR CONCRETE MASONRY UNIT CLEAN OUT COLUMN CONFERENCE CONCRETE CONTINUOUS COORDINATE CARPET CERAMIC TILE COLD WATER PENNY DOUBLR DEGREE DEMOLISH OR DEMOLITION DOUGLAS FIR DIAMETER DIAGONAL DIMENSION DOWN DOUBLE GLAZING DETAIL DOWNSPOUT DISH WASHER EXISTING EAST OR EXISTING EACH EXTERIOR INSULATION FINISH SYSTEM ELECTRICAL EXTERIOR ELEVATION EQUIPMENT EQUAL EACH WAY EXISTING FLOOR DRAIN FOUNDATION FIRE EXTINGUISHER CABINET FF FOC FOF FOS FTG FT FURN GA GALV GL GLB GLZ GYP GWB HB HC HMO HDR HOW HF HGT HM HR HW IBC ID IFC IN INSUL INT IPC IRC LAM LAV LB LF LT LWC MATL MAX MECH MFR MIN MIR MISC FINISH FLOOR FACE OF CONCRETE FACE OF FINISH FACE OF STUD FOOTING FOOT OR FEET FURNITURE GAUGE OR GAGE GALVANIZED GLASS GLUE LAMINATED BEAM GLAZING GYPSUM GYPSUM WALL BOARD HOSE 515 HOLLOW CORE HARDWOOD HEADER HARDWARE HEM -FIR HEIGHT HOLLOW METAL HOUR HOT WATER INTERNATIONAL BUILDING CODE INSIDE DIAMETER INTERNATIONAL FIRE CODE INCHES INSULATION INTERIOR INTERNATIONAL PLUMBING COPE INTERNATIONAL RESIDENTIAL CODE LAMINATE LAVATORY POUNDS LINEAR FEET LIGHT LIGHT WEIGHT CONCRETE MATERIAL MAXIMUM MECHANICAL MANUFACTURER MINIMUM MIRROR MISCELLANEOUS NEC NATIONAL ELECTRICAL CODE (N) NEW N NORTH OR NEW NIC NOT IN CONTRACT NO. NUMBER NOM NOMINAL NRC NOISE REDUCTION COEFFICIENT NTS NOT TO SCALE OC ON CENTER OPNG OPENING PL P LAM PLYWD PROPERTY LINE OR PLATE PLASTIC LAMINATE PLYWOOD PNL PROP PT FTD R RA RAP RCP REINF REQD RM RO PANEL PROPERTY PRESSURE TREATED PAINTED RISER OR RADIUS RETURN AIR RADIUS REFLECTED CEILING PLAN REINFORCING REQUIRED ROOM ROUGH OPENING 5 SOUTH SA SUPPLY AIR SC SOLID CORE SCHED SCHEDULE 5D STORM DRAIN SECT SECTION 5F SQUARE FEET SIM SIMILAR SPEC SPECIFIED OR SPECIFICATION 55T STAINLESS STEEL STC SOUND TRANSMISSION COEFFICIENT STD STANDARD STL STEEL STOR STORAGE STRUCT STRUCTURAL SUSP SUSPENDED SYS SYSTEM T T&G TB TOW TEMP TH K THRU TOPO TPD TYP UNO UTIL VCT VERT VEST VTR VTO TREAD OR TEMPERED TOUNGUE AND GROOVE TOWEL BAR TOP OF WALL TEMPERED THICK OR THICKNESS THROUGH TOPOGRAPHIC MAP TOILET PAPER DISPENSER TYPICAL UNLESS NOTED OTHERWISE UTILITY VINYL COMPOSITION TILE VERTICLE VESTIBULE VENT THROUGH ROOF VENT TO OUTSIDE W WEST W/ WITH WC WATER CLOSET WD WOOD WDW WINDOW WF WIDE FLANGE WG WIRE GLASS WH WATER HEATER W/0 WITHOUT WP WATERPROOF WSEC WASHINGTON STATE ENERGY CODE WT WEIGHT WWF WELDED WIRE FABRIC WWM WELDED WIRE MESH YD YARD PLUMBING FIXTURE CALCULATIONS PER 2012 IBC CHAPTER 29 (3 PLAN) OCCUPANCY: OCCUPANT LOAD: OCCUPANT RATIO: REQUIRED FIXTURES: (2012 IBC TABLE 2902.1) (2012 IBC 2902.5.1) PROVIDED FIXTURES: 'F' FACTORY /WAREHOUSE USE 'B' OFFICE USE 39 /2 = 19.5 EACH SEX 20 WOMEN & 20 MEN FIXTURE WATER CLOSET LAVATORY DRINKING FOUNTAIN FIXTURE WATER CLOSET URINAL LAVATORY DRINKING FOUNTAIN WOMEN / MEN 1 PER 25 FOR FIRST 50 - 40/25 = 2 1 PER 40 FOR FIRST 80 - 40/40 = 1 1 PER 150 - 141/150 = 1 DU; RY D SITE PLAN 1 1 / / / / / / r TOTAL 2 1 TOTAL 3 1 3 1 / i PLANNING NOTES PROJECT NOTES ZONING: LOT AREA: LOT COVERAGE: HEIGHT: PARKING PROPOSED USE EXISTING MINI MARKET WAREHOUSE STORAGE TOTAL PARKING: TUC -TUKWILA URBAN CENTER - WORKPLACE CORRIDOR CHANGE OF USE WAREHOUSE TO INDUSTRIAL COMMERCIAL SERVICES (PRINTING) 49,972 SF (1.15 ACRES) 16,829 SF (NO CHANGE) 21 FT (NO CHANGE) AREA (SF) 3,772 SF 8,243 SF 4,203 SF RATIO (STALL/SF) 1/300 1/1000 1/2000 40 STALLS TOTAL (NO CHANGE) EA OF WORK REQ'D STALLS 13 9 3 25 PROVIDED 18 14 8 40 REVISIONS No changes shag be made to the scope of work without prior approvwl of i zkvti!a Building Division. will quire a new pian submittal and may include additional plan review fees. PLANNING APPROVED • No changes .car' be madeto these plans without approval from the Planning Division of DCD • Approved By: :?:'ate: �`•�<<� SER''':PATE PERMIT 'E I.'PED FOR: Mechanical Eg/Stectrical Rnumbirtg ilAas Piping 11 of Tukwila et.YI r" NG DIVISION Permit LE COPY o. 1 (0 - 00`13 Plan review ap ,rovE l is subject to errors and oiimi33ions. A ;oval of cons ruc ion documents doss not ECIli tiZB tio vin(° bn cf nJ adop o d codo or ordinance::. Receipt a. a pi T :'cfi=ield Copy and conditions is acknowledged: By: 3• Date: City of Tukwila BUILDING DIVISION ANN = 20' 0 10' 20' 40' PROJECT ADDRESS: PROJECT DESCRIPTION: OWNER: ARCHITECT: LEGAL DESCRIPTION: PARCEL NUMBER: 345 ANDOVER PARK EAST TUKWILA, WA #Site Postcode DIECUT PRINTERS TENANT IMPROVEMENT DANIEL DIEDERICHS 503 S. MICHIGAN STREET SEATTLE, WA 98108 206.816.3421 BRODERICK ARCHITECTS 55 S. ATLANTIC STREET, SUITE 301 SEATTLE, WA 98134 206.682.7525 206.682.7529 CONTACT ALENETOROSSIAN info@broderickarchitects.com ANDOVER INDUSTRIAL PARK # 5 SLY 199.49 FT OF ELY 259.43 FT AS MEAS ALG N LN OF SD SLY 199.49 FT 022340-0040 BUILDING NOTES NUMBER OF STORIES: HEIGHT: GROSS SF: 1, (NO CHANGE) 21 FT (NO CHANGE) WAREHOUSE: (E) MINI MARKET: (E) STORAGE: 8,243SF 3,772 SF 4,203 SF TYPE OF CONSTRUCTION: OCCUPANCY TYPE: TI NOTES TOTAL: VB 16,2183 SF (NO CHANGE) 'F' FACTORY (WAREHOUSE) USE - (WITH SOME OFFICES IN WAREHOUSE) GROSS SF: TYPE OF CONSTRUCTION: OCCUPANCY TYPE: CHANGE OF USE: TOTAL OCCUPANT LOAD: SPRINKLERS: ALLOWABLE AREA: BLDG ARE.: SUMMARY: APPLICABLE CODES: WAREHOUSE: OFFICE: TOTAL: VB 5,592 SF 2,651 SF 8,243 SF 'F' FACTORY (WAREHOUSE) USE - (WITH SOME OFFICES IN WAREHOUSE) EXISTING S1 CHANGE TO F1 USE IBC Table 508.4: no separation required B, F1 & S1 IBC Table 1604.5 has the existing B occupancy and the proposed F1 both with a risk rating of II. The proposed project does not trigger Substantial Improvement as defined by definition in IBC 202 since the valuation is significantly less than 50% of the appraised value. 39 TOTAL WAREHOUSE AREA: 5,592 / 500 = 12 OFFICE AREA: 2,651 / 100 = 27 YES NA, NO INCREASE PROPOSED EXISTING OFFICE /WAREHOUSE SPACE . ALL EXISTING INTERIOR WALLS TO BE DEMO AND PROVIDED WITH NEW GWB PARTITIONS, NEW PLUMBING, NEW CEILING, NEW POWER AND DATA, NEW LIGHTING AND SWITCHING, AND NEW INTERIOR FINISHES. (ONLY EXTERIOR WORK TO DEMP (E) GARAGE DOOR AND REPLACE WITH NEW STORE FRONT SYSTEM & DEMO) 2012 IBC W/ CITY OF TUKWILA AMENDMENTS, 2012 WA ENERGY CODE, 2012 WAVIAQ 2012 INTERNATIONAL FIRE CODE ICC A117.1-2009 ACCESSIBLE AND USABLE BUILDING AND FACILITIES DEFERRED SUBMITTALS: FIRE SPRINKLER, FIRE ALARM, MECHANICAL, PLUMBING, ELECTRICAL RECEIVED CITY OF TUKWILA SHEET INDEX MAR 212016 PERMIT CENTER A1.0 TITLE SHEET A2.0 DEMO PLAN A2.1 FLOOR PLAN A2.2 REFLECTED CEILING PLAN A2.3 POWER/DATA PLAN A2.4 FLOOR FINISH PLAN - MAIN LEVEL A3.1 ELEVATIONS & ENLARGED PLAN A4.1 WINDOW & DOOR SCHEDULES A4.2 INTERIOR DETAILS & SCHEDULES bi 0073 Weft Fargo (Link General Tool 3 Supp,i. 7 IS Pao Painting Varna:, Teti, aki it 345 Andover Park E industly Dr REVIEWED FOR ODE COMPLIANCE ' APPROVED mg 0 5 2016 CDVICINTY MAP N.T.S. iZ- UILDING DIVISION RE614) I ED ARCHITECT DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST • TUKWILA, WA #Site Postcode 16.003 Plot Date: 3/17/16 Alene Torossian 16.003-Diecuts Printers- AC19.pin IR. RCH 0 ::-1 cn NO. DATE DESCRIPTION 3/17/16 TITLE SHEET Al .0 This document represents a proprietary design owned by the architect and shall not be used on other projects or additions to this project or for completion of this project by others except by prior arrangement in writing. Copyright 0 Thursday, March 17, 2016 by Broderick Architects, pile (A (D E F 1 4,1 2 • _ _ ' 3 ) (4 • • • • • • DEMO EXISTING INSULATION ON THE UNDERSIDE OF CEILING DECK ( 6 DEMO FOR FOOTING DEMO FOR FOOTING _FT — tc) t 13'-10 1/4" DEMO RESTROOM PARTITION. 14'-9 3/4" DEMO FOR FOOTING DEMO EXISTING DOOR AND WALL DEMO GARAGE DOOR 1 PEMO PLAN 3(') (4; LDEMO EXTERIOR AWNING DEMO FOR FOOTIFIG L 3'-4" ( 7 3Z-6 3/4" 110 DEMO FLOOR PLAN LEGEND: A DEMO PORTION OF WALL FOR NEW EXTERICR OPENIN3 DEMO FOR FOOTING DEMO INTERIOR PARITONS AND DOORS (7) Id Ij ( 7 ) 9 ) E) F A2.O 1/8" = 0 4' 8' 16' REVIEWED FOR CODE COMPLIANCE '• APP'OVED MAY 0 5 2016 City of 'Tukwila BUILDING DIVISION RECEWED CITY OF TUKWILA MAR 2 1 2016 PERMIT CENTER 7 3 45n RARCHITECT EXISTING EXTERIOR WALL TO REMAIN I I I DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST * TUKWILA, WA #Site Postcode - • ' EXISTING WALL TO BE DEMOLISHED EXISTING ITEM TO BE DEMOLISHED (CASEWORK, EQ(JIPMENT, DOOR, ETC) .. , . I NO WORK IN SHADED AREA A DEMO PORTION OF WALL FOR NEW EXTERICR OPENIN3 DEMO FOR FOOTING DEMO INTERIOR PARITONS AND DOORS (7) Id Ij ( 7 ) 9 ) E) F A2.O 1/8" = 0 4' 8' 16' REVIEWED FOR CODE COMPLIANCE '• APP'OVED MAY 0 5 2016 City of 'Tukwila BUILDING DIVISION RECEWED CITY OF TUKWILA MAR 2 1 2016 PERMIT CENTER 7 3 45n RARCHITECT I 0 I DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST * TUKWILA, WA #Site Postcode I I 16.003 Plot Date: 3/17/16 Alene Torossian 16.003 -Diecuts Printers- AC19.pin KARCI I NO. DATE DESCRIPTION I 3/17/16 I•I DEMO PLAN A 2 0 on of this project by others except by prior arrangement in writing. Copyright 0 Thursday, March 17, 2016 by Broderick Architects, pile ons to this project or for compl tary design owned by the architect and shall not be used on other projects or addit This document represents a p B Cr ( F _;\ 3 c'1_ ti) 0 0 WALL ASSEMBLIES: DETAIL 1/A4.2 EXISTING WALL TO REMAIN INTERIOR WALL Q ,. il -5/8" GYPSUM BOARD W1 (WITH 1" TYPE S DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C. AT FLOOR AND CEILING RUNNERS AND INTERMEDIATE STUDS. TYP.) NEW INTERIOR WALL -3 1/2" METAL STUDS @ 16" O.C. - SOUND BATT INSULATION -5/8" GYPSUM BOARD DETAIL 2/A4.2 PLUMBING WALL NEW PLUMBING WALL ) i 5/8" GREENBOARD (INTERIOR FACE) W2 (WITH 1"TYPE S DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C. AT FLOOR AND CEILING RUNNERS AND INTERMEDIATE STUDS. TYP.) -5 1/2" METAL STUDS @ 16" O.C. NEW INSTALLATION ON EXISTING WALL } 5/8" GWB PONY WALL @ 4'-0" A.F.F. PERIMETER WALL ° " -5/8" GYPSUM BOARD W3 (WITH 1" TYPE S DRYWALL SCREWS 8" O.C. AT VERTICAL JOINTS AND 12" O.C. AT FLOOR 7 7 "I r T "'t"" A. A A A. A A A, A AND CEILING RUNNERS AND INTERMEDIATE STUDS. TYP.) -5 1/2" METAL STUDS @ 16" O.C. - R-21 SOUND BATT INSULATION GYPSUM BOARD -5/8" -EXISTING CONCRETE WALL NOTE: GWB TO 10'-0" A.F.F (INSULATION EXPOSED ABOVE) NOTE: ALL WALL HEIGHTS AT 10'-0" A.F.F., U.O.N. 81' 13'-3" 18'-31/2" 13'-11/2" 8'-1/2" 17-9 1/2" 10'-6" W3 PRESIDENT OFFICE 113 sr W1 5`) T-6 1 /2" 5'-10 1/2" 12'-5" 6 ) 5'-7" DAD'S OFFICE 114 174 SF SALES ADVISORS 13'4 109 427 5F W3 PROVIDE NEW 3' X 3' FOOTINGS In N PROVIDE BACKING IN WALL TO MIRROR EXISTING PLUMBING FIXTURES TO REMAIN W2 jRR 2 103 °6;68 5F . ROOM 112 _ 42 SF i VP OFFICE 115 124 SF PROVr1 EA5'X5'PAD FOR NEW EXTERIOR DOOR 18 PROVIDE NEW 3' X f. 3 FOOTINGS NI P • ATIONS MANAG -11r- 122 SF MARKETING DEPT 110 189 SF W1 PROVIDE NEW 3'X3' ' FOOTINGS i I LPROVIDE NEW 3' X 3' FOOTINGS 19 Er) —4 \--d) 4'-0" HIGH WALL AREHOUSE SUPERVISOR BREAK ROOM 108 241 SF II t. L-_ 11 ' `k KITCHEN SINK TO HAVE A DISPOSA WI STANDARD 9'-6" WALLS ADMIN 101 67 5F 5'-10 1 /2" . #4 - FUT(JRE WORK III PRTVIDE A LOW HE GHT ' DR NKING FOUNTAIN WAITING / L01313 100 70b bF- 10'-9 1/2" Y W3 — 119 262 SF PROVIDE NEW 3' X 3' FOOTINGS CONFERENCE R00 115 232 5F �5 f EMPLOYEE SIGN IN COMPUTER CUSTOMER& VENDOR PICK UP / DROP OFF AREA S STAFF E ELEC. ALREPAINT HM DOOR L TO MATCH EXTERIOR 1 OF BUILDING 4'-3" 13'-T' 0) W3 PRINTERS & EQUIPMENT 116 496 5F PRE -PRESS ART DEPT. 117 185 61 - WI DIGITAL DEPARTMENT 0 DIECUT DEPARTMENT QUALITY • NTROL 121 323 5F I CV I) SHIPPING ARER 1 123 690 SF 20'-6 1/2" 120 1,450 5F W3 8'-0" HIGH CHAIN LINK FENCE 4'-0" HIGH WALL ADD ALT. #1 - GARAGE DOOR W3 STORAGE 122 N N / N / /N / N 190 SF FLOOR PLAN -MAIN LEVEL 0'` �B. E F G A2.1 1/8" = 1'-0" 0 4' 8' 16' 1111111111 FLOOR PLAN LEGEND: NOTES: 1) CONTRACTOR SHALL DIVERT AS MUCH OF THE DEMOLISHED MATERIALS FROM THE LANDFILL AS POSSIBLE BY MEANS OF RECYCLING, DONATION, ETC. 2) SEE SHEET A3.1 FOR ADDITIONAL DIMENSIONS. 3) SEMI -HEATED AT ALL OPEN AREA 4) HEATING / COOLING SPLIT UNIT IN OFFICES ONLY ADD ALTERNATE: 1. NEW GARAGE DOOR- (SEE SHEET A2.1) 2. FULL HEIGHT INTERIOR WINDOWS - (SEE WINDOW SCHEDULE ON A4.1). PROVIDE FULL HEIGHT WINDOWS WITH NO SILL. 3. DOOR GLAZING INSERT (SEE DOOR SCHEDULE A4.1) PROVIDE A WOOD DOOR WITH NO GLAZING INSERT. 4. FUTURE RESTROOM 106 AND ALL RESTROOM ASSESORIES & PLUMBING FIXTURES - (SEE SHEETA2.1) REVIEWED FOR CODE COMPLIANCE ',. APP OVER MAY 0 5 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 212016 PERMIT CENTER EXISTING WALL TO REMAIN 1 t7 1ff"~ I NEW INTERIOR WALL DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST • TUKWILA, WA #Site Postcode I I NEW PLUMBING WALL f L UJ <. E Ln W NEW INSTALLATION ON EXISTING WALL ",1)YM` '"'SAA6 PONY WALL @ 4'-0" A.F.F. NO. DATE DESCRIPTION FIRE EXTINGUISHER FEC ODOOR TAG OWINDOW TAG F�= NO WORK IN SHADED AREA -�-0" FLOOR ELEVATION MARKER eELEVATION I SECTION MARKER 3/17/16 I gai ENLARGED PLAN MARKER FLOOR PLAN # CONSTRUCTION ASSEMBLY TYPE - NOTES: 1) CONTRACTOR SHALL DIVERT AS MUCH OF THE DEMOLISHED MATERIALS FROM THE LANDFILL AS POSSIBLE BY MEANS OF RECYCLING, DONATION, ETC. 2) SEE SHEET A3.1 FOR ADDITIONAL DIMENSIONS. 3) SEMI -HEATED AT ALL OPEN AREA 4) HEATING / COOLING SPLIT UNIT IN OFFICES ONLY ADD ALTERNATE: 1. NEW GARAGE DOOR- (SEE SHEET A2.1) 2. FULL HEIGHT INTERIOR WINDOWS - (SEE WINDOW SCHEDULE ON A4.1). PROVIDE FULL HEIGHT WINDOWS WITH NO SILL. 3. DOOR GLAZING INSERT (SEE DOOR SCHEDULE A4.1) PROVIDE A WOOD DOOR WITH NO GLAZING INSERT. 4. FUTURE RESTROOM 106 AND ALL RESTROOM ASSESORIES & PLUMBING FIXTURES - (SEE SHEETA2.1) REVIEWED FOR CODE COMPLIANCE ',. APP OVER MAY 0 5 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 212016 PERMIT CENTER ..........„ t7 1ff"~ I I DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST • TUKWILA, WA #Site Postcode I I 16.003 Plot Date: 3/17/16 Alene Torossian 16.003 -Diecuts Printers- AC19.pin f L UJ <. E Ln W DERICK ARCI CD Ce NO. DATE DESCRIPTION I 3/17/16 I I FLOOR PLAN ing. Copyright m Thursday, March 17, 2016 by Broderick Architects, pile This document represents a proprietary design owned by the architect and shall not be used on other pr 1 A RCP - MAIN FLOOR LIGHTING FIXTURE SCHEDULE: ID STYLE MANUFACTURER ITEM NUMBER FINISH LAMPING VOLTAGE WATTS PER FIXTURE QUANTITY TOTAL WATTAGE NOTES A PENDANT INDIRECT/DIECT - 59M -P LIGHTCONTROL 59M -P -ID -04 -13W -CX -2T5 WHITE (2) T5 120 26 91 2366 1, 3 B 2 X 4 RECESSED TROFFER FOCAL POINT LED 2 X 4 LUNA RECESSED LUMINAIRE WITH CENTER BASKET WHITE LED 120 26 46 1196 1 C RECESSED CAN LIGHTOLIER # 1104F2632ES FRAME -IN KIT w/ #1171 TRIM WHITE (1) 26W TRIPLE TUBE 4 -PIN CFL 120 26 4 104 1 9 EXIT SIGN HUBBELL LIGHTING DUAL LITE - HCX SERIES HCXUGW-03L WHITE FACE w/ GREEN LETTERS (1) 1W LED 120 10 3 30 2 E EXIT SIGN DIRECTIONAL HUBBELL LIGHTING DUAL LITE - EVC SERIES EVCUGWD WHITE FACE w/ GREEN LETTERS (1) 1W LED 120 1.65 2 3.3 1 F WALL VALENCE LITE CONTROL V3 ADJUSTABLE WALL VALENCE 34-W WHITE (1) 2T5 120 26 3 78 1 G EMERGENCY LIGHTING LITHONIA LIGHTING THERMOPLASTIC EMERGENCY RG LIGHTING ELM2 WHITE (1) 2T5 120 1.44 5 7.2 1 NOTES: 1. VERIFY WITH OWNER PRIOR TO ORDERING. 2. MOUNT ABOVE DOOR 3. SUSPEND 11'-0" FROM FLOOR. ,3. 1 TOTAL INTERIOR WATTAGE: 'MIMI= III MIMI III `® 111 1 �■ ■�� �: 'IP SOF1 ' � 1111 GU BO 5 LES A 1►VISOR • do ;Ern _- • Bf 1 111 1 � MA ' KFTI bF' IEEE wou manAloses i4P. g' 1111 1111 1E11 IRE I 11111 �B B — 1 A A c A 5 O RAG Rem 1 r ADM' 1 A • • J 1--` / \ 'ARE IIOD TU 1 119 r- 262 262 SF I RZVISaR elm A C WP.ELNC R i1'J' 232 SF OK/ OPEN CEILIN WAITING LOBBY PzonoE VAPOR v, WAREHOUSE PROVIDE NEW R-49 BATT POLY FACE BARRIER ON UNDERSIDE OF ROOF DECK THROUGHT-OUT WAREHOUSE A I A EX 19 ELEC. v 1 ♦ N A 1 OPEN CEILING 1 IF A 0 EXIT A INNIMP A A A A 3706.5 PROVIDE NEW R-49 BATT PO_Y FACE VAPOR BARRIER ON UNDERSIDE OF ROOF DECK 7HROUGHT-OUT WAREHOUSE tRINTF \B RS & FlIJIP T B CEILING ASSEMBLIES: C-1 GWB CEILING -TRUSS PER STRUCTURAL -R49 BLOWN INSULATION - AIR BARRIER -1/2" GYPSUM CEILING BOARD SUSPENDED CEILING C-2 -SUSPENDED ACOUSTIC TILE CEILING SYSTEM PER MANUFACUTERS SPEC. - ACOUSTIC CEILING TILE DIGITAL DEPARTMENT 115 1,41'Ts'-- PROVIDE NEW R-49 BATT FOLY FACE VAPOR BARRIER ON UNDERSIDE OF ROOF DECO THROUGHT-OUT WAREHOUSE - A — DIECUT RI+PARTME A / A A aim QUALITY CONTROL 121 323 SF SHIPPING AREA —'23 69pF— A A Met A 0 rt F A A A A Amman Oro 1 r A • A A OPEN CEILIN A A ORAGE 1 A i 9`; REFLECTED CEILING PLAN LEGEND: NOTES: 1) INSTALL MOTION DETECTION LIGHT SWITCHES IN OFFICE AS REQUIRED BY CODE. 2) INSTALL DIMMER SWITCH FOR RECEPTION AREA LIGHTING. 3) NEW LIGHTINGTHROUGHTOUT. ENERGY CODE NOTES 1) ALL WORK SHALL COMPLY WITH THE 2012 WA ENERGY CODE PRESCRIPTIVE REQUIREMENTS OPTION 2. BELOW ARE THE REQUIREMENTS. (SEE A3.0 FOR DOOR & WINDOW SCHEDULES). 2) INSULATION (MIN. R -VALUE): ABOVE GRADE WALLS - R-21 (HEADERS INSULATED WITH R-10) 3) EXTERIOR DOORS (MAX. U -FACTOR): 0.40 D ., rE': A2.2 1/8" = 1'-0" 0 4' 8' 16' 0 EXCEPTION 1: GLAZED DOORS WHOSE AREA AND U -FACTOR ARE INCLUDED IN THE CALCULATIONS FOR COMPLIANCE WITH THE REQUIREMENTS FOR GLAZING SHALL BE EXEMPT FROM THE DOOR U -FACTOR REQUIREMENTS. EXCEPTION 2: ONE UNLABELED, UNTESTED SWINGING DOOR WITH A MAXIMUM AREA OF 24 SF MAY BE INSTALLED. REVIEWED FOR CODE COMPLIANCE n .. APPPOVEb ci A MAY 0 5 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF o UKWILA MAR 212016 PERMIT CENTER 7 0 0 • 206.682.7525 F— z LLJ DESCRIPTION 0 z 1 ■ 3/17/16 REFLECTED CEILING PLAN A2.2 2 x 4 RECESSED FLUORESCENT FIXTURE - NEW 1 x 4 SUSPENDED FLUORESCENT FIXTURE NEW - 0 RECESSED CAN - NEW S LIGHT SWITCH (ALL LOCATIONS SHOWN ARE NEW) B FAN - NEW <EXIT EXIT SIGN W/ DIRECTIONAL ARROWS - NEW 0. ExIT .4 EXIT SIGN WITH EMERGENCY LIGHTING - NEW t>04 EMERGENCY LIGHTING - NEW New 2 x 4 CEILING GRID - ARMSTRONG - DUNE 12 X 24 TILE; TEGULAR WITH SILHONETTE XL 9/16" SUSPENDED SYSTEM WITH 1/4" REVEAL NEW GWD CEILING NOTES: 1) INSTALL MOTION DETECTION LIGHT SWITCHES IN OFFICE AS REQUIRED BY CODE. 2) INSTALL DIMMER SWITCH FOR RECEPTION AREA LIGHTING. 3) NEW LIGHTINGTHROUGHTOUT. ENERGY CODE NOTES 1) ALL WORK SHALL COMPLY WITH THE 2012 WA ENERGY CODE PRESCRIPTIVE REQUIREMENTS OPTION 2. BELOW ARE THE REQUIREMENTS. (SEE A3.0 FOR DOOR & WINDOW SCHEDULES). 2) INSULATION (MIN. R -VALUE): ABOVE GRADE WALLS - R-21 (HEADERS INSULATED WITH R-10) 3) EXTERIOR DOORS (MAX. U -FACTOR): 0.40 D ., rE': A2.2 1/8" = 1'-0" 0 4' 8' 16' 0 EXCEPTION 1: GLAZED DOORS WHOSE AREA AND U -FACTOR ARE INCLUDED IN THE CALCULATIONS FOR COMPLIANCE WITH THE REQUIREMENTS FOR GLAZING SHALL BE EXEMPT FROM THE DOOR U -FACTOR REQUIREMENTS. EXCEPTION 2: ONE UNLABELED, UNTESTED SWINGING DOOR WITH A MAXIMUM AREA OF 24 SF MAY BE INSTALLED. REVIEWED FOR CODE COMPLIANCE n .. APPPOVEb ci A MAY 0 5 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF o UKWILA MAR 212016 PERMIT CENTER 7 0 0 • 206.682.7525 F— z LLJ DESCRIPTION 0 z 1 ■ 3/17/16 REFLECTED CEILING PLAN A2.2 I. A C G • • • • . . . i • • • • • • 1 • • 9 (4'. (5) ( 6 MRAMIMITOS^,WitANWINV=VMANWAT ••••• (I) DAD'S OFFICE ".....=SEA14.11.1W91=77.VZSIMINVIRM WE* - (7) (8) 9 174 SF PRINTERS & EQUIPMENT 496 SF PRESIDENT OFFICE 255 SF eA ES ADVISORS V (A- DEPT. I. . ROOM 112 42 SF 427 5F ATIONS MANAG 111 122 SF MARKETING DEP 159 SF DIGHT L DEPARTMENT 115 1,411 SF POWER AND DATA DROPS FOR SYSTEMS FURNITURE -1 3- .4)- AREHOUSE SUPERVISOR BREAK ROOM 119 262 5F 241 SF DIECUT DEPARTMENT 120 1,450 5F aiZAFF •42&F kFF CONFERENCE ROM/ -VT ADMIN 101 starawre" 115 .232 SF QUALITY CONTZOL 67 SF 121 323 5F vclP STORAGE 5 ORAG WAITING / LOBBY 100 SHIPPING AREA 706 SF 3 POWER / DATA PLAN - MAIN FLOOR ( 4 ') ( 5 ) 123 690 SF ELEC. db i go 190 5F H N1 NV zN. it- I z 7) (9) (1O' (A') C E F " G ) 1/8" = 16' POWER & DATA PLAN LEGEND: (0) DUPLEX RECEPTACLE DATA/ PHONE (2 CAT 6 PLENUM RATED CABLES) GENERAL NOTES: 1) ALL RECEPTACLES ARE NEW. 2) CONTRACTOR SHALL COORDINATE WITH TENANT'S LOW - VOLTAGE / IT VENDOR. 3) NEW SWITCHES SHALL BE LEVITON DECORA IN WHITE. 4) PROVIDE DEDICATED DUPLEX FOR COPIER'S AND MICROWAVE THROUGHOUT OFFICE AS NEEDED. COORDINATE WITH OWNER REVIEWED FOR !CODE COMPLIANCE r'e•' APPROVED ,A1 :'- MAY 0 5 2016 1 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 21 2016 PERMIT CENTER 4532 F ERGel Ti TE.EFicEria V,:sTSCA!: WrIaNctTAIAsn' 002.0701,CK I m 1 • DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST 0 TUKWILA, WA #Site Postcode ID 16.003 Plot Date: 3/17/16 Alene Torossian 16.003 -Diecuts Printers- AC19.pin , :.5--1 1..... Lu --i • KICK ARCI 0 Ce 01 . ID NO. DATE DESCRIPTION 3/17/16 POWER/DATA PLAN A2 3 This document represents a proprietary design owned by the architect and shall not be used on other projects or additions to this project or for completion of this project by others except by prior arrangement in writing. Copyright m Thursday, March 17, 2016 by Broderick Architects, pile FINISH FLOOR -MAIN FLOOR 3 FINISH FLOOR PLAN LEGEND: G1 1 COMMERCIAL GRADE CARPETING CON -1 45n ARCHITECT EXISTING CONCRETE FLOORING NOTES: 1) ALL FLOORING IN OFFICE'S ARE NEW. 2) NEW RUBBER BASE IS TYPICAL THROUGHOUT 3) THE COLUMNS AT GRIDLINE A SHALL BE PAINTED FIELD COLOR. 4) FLOORS SHALL SLOPE TO FLOOR DRAINS IN THE RESTROOMS 5) ALL COUNTERTOPS TO BE P -LAM; COLOR TBD. 6)ALL CABINETS TO BE P -LAM; COLOR TBD. 7) PAINT THROUGHOUT, ALL WALLS TO BE EGGSHELL FINISH; ALL HARDLID CEILINGS TO BE FLAT FINISH. 8)ALL RESTROOM TO HAVE P -LAM WAINSCOT; SEE ELEVATIONS. MANUFACTORTBD 9) ALL FINISHES TO BE COORDINATE WITH OWNER. FINISH SPECIFICATIONS: CARPET TILE C-1 MATERIAL: COMMERCIAL GRADE CARPETING MANUFACTURER: PATCRAFT 24 X 24 TILE SERIES: TBD COLOR: TBD LOCATION: THROUGHOUT IN CLOSED OFFICE'S U.O.N. - SEE PLAN EXISTING CONCRETE FLOORING CON -1 EXISTING TO REMAIN. PATCH, REPAIR, & SEAL. WALL BASE VB -1 MATERIAL: 4" VINYL WALL BASE MANUFACTURER: ROPPE COLOR: 193 BLACK BROWN LOCATION: TYPICAL NEW ACOUSTICAL CEILING TILE ACT -1 MATERIAL: ACOUSTICAL CEILING TILE MANUFACTURER: ARMSTRONG STYLE: 2'-0" x 4'-0" x 5/8" DUNN (OR APPROVED EQUAL) MATCH EXISITNG LOCATION: THROUGHTOUT SUITE AS NOTES SEE RCP PLAN A2.3 MAPLE CAP MC MATERIAL: lx NATURAL MAPLE TRIM FINISH: TBD LOCATION: TOP OF ALL 4'-0" PONY WALLS GENERAL NOTES: 1. ACCENT PAINT WALLS TBD 2. CEILING HARDLID PAINT TO BE PAINT 1 3. ALL WALL PAINT TO BE EGGSHELL FINISH; ALL CEILING PAINT TO BE A FLAT FINISH; 4. ALL FURNITURE PROVIDED BY OWNER ( 7 8 `) MILLWORK PL -1 PL -2 PAINT PT -1 PT -2 MATERIAL: PLASTIC LAMININATE MANUFACTURER: WILSONART STYLE: TBD LOCATIONS: ALL FACE OF CABINETS - UPPERS AND LOWERS. MATERIAL: PLASTIC LAMININATE MANUFACTURER: WILSONART STYLE: TBD LOCATIONS: ALL COUNTERTOPS. MATERIAL: MAIN PAINT MANUFACTURER: SHERWIN-WILLIAMS STYLE: TBD LOCATIONS: THROUGH -OUT U.O.N. - SEE PLAN MATERIAL: PAINT - ACCENT MANUFACTURER: SHERWIN-WILLIAMS STYLE: TBD LOCATIONS: SEE PLAN (10) 5I3EE 1T OFFICE 113 255 5F 124 5sooffF i" SALES ADVISORS DEPT. 1 • 109 4275F DEMI'_' EXISTING WALL AND FLOOR TILE., 1 1 1 I 1 1 1 I 1 BREAK ROOM 108 241 5F IMONORIMMIMAS MQ LT. ROOM 112- 42 5F PHOTO 1 PERATIONS MANAG:' MARKETING DEPT; • RR 1- tOR AGF TU1�E1 >1 • v mFrr ADMIN` 101 675F . DIGITAL SUPERVISER AREH . SE SU ERVISOR 4 DIECUT SUPERVISER CO Otv 0-U A I U -(J WORKTABLE 4'-0' X 8'-0" WORKTABLE X 8'-O" WORKTABLE 4'-O' X B' -O" WORKTABLE 1 AIR 1 RGERPRINTER StRUBBFL 1 1 1 L PRINTERS & EQUIPMENT 116 LARGER PRINTER. 1 LARGER PRINTER DEPARTMENT - X •- WORKTABLE 5'-O" X 10'-0" WORKTABLE ROLLING' STANDS 4'-0' X B' -O" WORKTABLE 4'-0" X S' -0 - WORKTABLE VI=CUT 4'-0" X 8'-O" WORKTABLE 4'-0' X 8'-0' WORKTABLE WAITING / LOBBY •100. 70.65F `5) ELEC. 1L_sE 4'-0' X 8'-O" WORK TAU. 4'-O' X 8' -0 - WORKTABLE X 8'-O" WORK TAB 4'-0' X 8'-O" WORKTABLE 4'-0" X 8'-O" WORKTABLE - -2 CONTROL 121 '-O"X6'-O" SHIPPIN WORKTABLE O X fC O F 323 SF SHIPPING AREA 123 1 2'-6 X7-6"SHRINK 1 IWRAPPING MACHINE - 1 X 6'-0" TABLE 4'-O' X 8'-O" WORKTABLE 2OLLING STANDS ("EALEIL MiLtWIE (10 E _REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 5 2016 Cif' of ilkwyta BUILDING DIVISION re--, RECEIVED, CITY OF TUKWILA MAR 212016 PERMIT CENTER A2.4 1/8" = 1'-0u 1 45n ARCHITECT 1 1 DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST • TUKWILA, WA #Site Postcode 1 1 16.003 Plot Date: 3/17/16 Alene Torossian 16.003 -Diecuts Printers- AC19.pin DERICK ARCI I NO. DATE DESCRIPTION I 3/1 7/1 6 1 ___ FLOOR FINISH PLAN - MAIN LEVEL This document represents a proprietary design owned by the architect and shall not be used on other projects or additions to this project or for completion of this project by others except by prior arrangement in writing. Copyright m Thursday, March 17, 2016 by Broderick Architects, pile (V LA COFFEE MAKER REF 3'-4' ), 2' COFFEE BAR 0 CV A3.1 1/2" = 1'-0" ...-1X1 WOOD TRIM P -LAM WAINSCOT TUBBER 6A I '-11" RESTRO5OM 1 1/2" = 1'-O" 2'-9 1/2" I, 3'-4 1/2" 1'-&" KITCHEN 1/2" = 1'-0" 2'-T' 3'-3 1 /2" RESTROOM ACCESSORIES SCHEDULE: 1' MIRROR - PROVIDE BACKING TO FLUSH OUT WITH P -LAM PAPER TOWEL DISPENSER SOAP DISPENSER MIRROR - PROVIDE BACKING TO FLUSH 0 WITH P -LAM FUTURE RESTROOM 2 1/2" = 1'-0" REF. COFFEE MAKER 2' 5'-1" 5'-1" CONFERENCE ROOM 1/2" = 1'-0" ACCESSORY ROOM LOCATION MANUFACTURER ITEM NUMBER DESCRIPTION COLOR / FINISH QUANTITY NOTES GRAB BAR RESTROOMS BOBRICK 5-6806 x 18 18" VERTICAL GRAB BAR STAINLESS STEEL 2 1 GRAB BAR RESTROOMS BOBRICK 5-6806 x 24 24" HORIZONTAL GRAB BAR STAINLESS STEEL 2 GRAB BAR RESTROOMS BOBRICK 5-6806 x 42 42" HORIZONTAL GRAB BAR STAINLESS STEEL 2 1 TOILET PAPER DISPENSER RESTROOMS BOBRICK 5-4288 CONTURA SERIES SURFACE -MOUNTED MULTI -ROLL TOILET TISSUE DISPENSER STAINLESS STEEL 2 1 PAPER TOWEL DISPENSER RESTROOMS & KITCHEN BOBRICK B-4262 CONTURA SERIES SURFACE -MOUNTED PAPER TOWEL DISPENSER STAINLESS STEEL 4 1 SOAP DISPENSER RESTROOMS & KITCHEN BOBRICK 8-2111 CLASSIC SERIES - SURFACE -MOUNTED SOAP DISPENSER STAINLESS STEEL 4 1, 2 MIRROR RESTROOMS BOBRICK 13-293 2436 24" x 36" TILT MIRROR WITH STAINLESS STEEL FRAME STAINLESS STEEL 3 1 NOTE: COORDINATE ACCESSORIES WITH OWNER PRIOR TO ORDERING. PLUMBING FIXTURE SCHEDULE: FIXTURE ROOM LOCATION MANUFACTURER ITEM NUMBER DESCRIPTION COLOR / FINISH QUANTITY NOTES ADA TOILET RESTROOMS (#105& 106) KOHLER K-4405 HIGHLINE ELONGATED TOILET BOWL WHITE 2 1 TOILET SEAT RESTROOMS (#105& 106) KOHLER K -4731-C STRONGHOLD COMMERCIAL HEAVY-DUTY TOILET SEAT WHITE 2 ADA FLUSHOMETER RESTROOMS (#105& 106) KOHLER K-10673 BATTERY POWERED FLUSHOMETER (LOW CONSUMPTION, 1.6 GPF) CHROME 2 1 URINAL RESTROOM (#105) KHOLER K -5452 -ET DEXTER 0.125 GPT. 1 -PINT URINAL WHITE 1 1 ADA LAVATORY RESTROOMS (#105& 106) KOHLER K-2210 CAXTON BATHROOM SINK WHITE 2 1 ADA FAUCET RESTROOMS (#105& 106) SLOAN EBF-187-4-BDM OPTIMA PLUS BATTERY POWERED HAND WASHING FAUCET POLISHED CHROME 2 1, 2 ADA SINK BREAK ROOM (#108) STERLING 11402 SOUTHHAVEN TOP -MOUNT KITCHEN SINK STAINLESS STEEL 1 1 ADA FAUCET BREAK ROOM (#108) KOHLER K -10433 -CP FORTE KITCHEN SINK FAUCET POLISHED CHROME 1 1, 2 DRINKING FOUNTAIN HALLWAY HAWS 1001 BARRIER -FREE WALL MOUNT FOUNTIAN (ADULT ADA / ADULT) STAINLESS STEEL 1 1 NOTES: 1. PLUMBING FIXTURES MUST COMPLY WITH ANSI A117.1-2003. 2. ADA FAUCET 15 REQUIRED TO HAVE A MIXING VALVE TO LIMIT WATER TEMPERATURE T0110 DEGREES FARENHEIT. 1' PAPER TOWEL DISPE 50AP DISPENSER 0 4 KITCHEN 2'-6" 2'-8" SOAP DISPENSER II 1' 2' 2' 2'-4" 1'-7 1/2" 1, A3.1 1/2" = 1'-0" PROVIDE BACKING IN WALL TO FOR TV BREAK ROOM 108 LL II II Li F-1 T-91 /2" L L 11 SOAP DISPENSER KITCHEN SINK TO - HAVE A DISPOSAL WATER 4 COOLER LOCATION PROVIDED BY OWNER PROVIDE A 36" X 36" PAD FOR FUTURE MEZZANINE SUPPORT M4 r- ��� r� _ L. , I r PAPER TOWEL OAP DISPENSER MIRROR PROVIDE BACKING IN WALL TO MIRROR URINAL RR 1 105 P -LAM PARTITION 6'-7 1 /2" SOAP DISPENSER O) PAPER TOWEL ADD ALT. FUTURE WORK J MIRROR , FUTURE.RR f' 106 PROVIDE BACKING IN WALL TO MIRROR 6'-T, • • I v PROVO HEIGH' DRINKII FOUNT ENLARGED RESTROOMS AND KITCHEN 3.1 1/2" = 1'-0" REVIEWED FOR 'CODE COMPLIANCE APPOVEDI MAY 052016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 212016 PERMIT CENTER 7 HqI* I , DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST 0 TUKWILA, WA #Site Postcode I I 16.003 Plot Date: 3/17/16 Alene Torossian 16.003 -Diecuts Printers- AC19.pin BRODERICK ARCI r• 1 n ♦ T■ ♦\ t 'r i t r- i- n r r- n, t r -r- r- 1[ •-1 n w I NO. DATE DESCRIPTION I 3/17/16 I D I ELEVATIONS & ENLARGED PLAN ht m Thursday, March 17, 2016 by Broderick Architects, pllc cts or additions to this project or for completion of this project by others except by prior arrangement in writing. Co tory design owned by the architect and shall not be used on other pr This document represents a prop Diecut Printers TI Tukwila, WA HARDWARE SCHEDULE HW SET: 01 FOR USE ON DOOR # 01 EACH TO HAVE: QTY 2 EA 2 EA 1 EA 1 EA 2 EA 1 EA 1 EA 2 SET 2 EA 2 EA 2 EA 2 EA 1 EA 1 EA HW SET: 02 DESCRIPTION PIVOT SET INTERMEDIATE PIVOT HEADER BOLT 3 POINT LOCK MORTISE CYLINDER EXIT INDICATOR TRIM STRIKE PUSH/PULL BAR SURFACE CLOSER CUSH SHOE SUPPORT BLADE STOP SPACER DOOR SWEEP THRESHOLD FOR USE ON DOOR # 02 04 EACH TO HAVE: QTY 3 EA 1 EA 1 EA 1 EA 1 EA 3 EA HW SET: 03 DESCRIPTION HINGE STOREROOM LOCK SURFACE CLOSER KICK PLATE WALL STOP SILENCER FOR USE ON DOOR # 03 07 EACH TO HAVE: QTY DESCRIPTION 3 EA HINGE 1 EA PRIVACY LOCK 1 EA 1 EA HW SET: 04 WALL STOP GASKETING FOR USE ON DOOR # 05 EACH TO HAVE: QTY DESCRIPTION 3 EA HINGE 1 EA PASSAGE SET EA EA EA EA HW SET: 05 SURFACE CLOSER KICK PLATE WALL STOP GASKETING FOR USE ON DOOR # 06 09 22 EACH TO HAVE: QTY DESCRIPTION 3 EA 1 EA 1 EA 1 EA HW SET: 06 HINGE PASSAGE SET WALL STOP GASKETING FOR USE ON DOOR # 13 14 EACH TO HAVE: QTY DESCRIPTION 3 EA HINGE 1 EA ENTRY / OFFICE LOCK 1 EA WALL STOP 1 EA GASKETING HW SET: 07 FOR USE ON DOOR # 19 EACH TO HAVE: QTY 3 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA 1 EA HW SET: 08 DESCRIPTION HINGE STOREROOM LOCK SURFACE CLOSER KICK PLATE RAIN DRIP GASKETING DOOR SWEEP THRESHOLD FOR USE ON DOOR # 20 EACH TO HAVE: QTY 6 EA 2 EA 1 EA 1 EA 2 EA 2 EA HW SET: 09 DESCRIPTION HINGE MANUAL FLUSH BOLT DUST PROOF STRIKE CLASSROOM LOCK OH STOP SILENCER FOR USE ON DOOR # 23 EACH TO HAVE: QTY 6 EA 2 EA 1 EA 1 EA 1 EA 1 EA 2 EA 1 EA 2 EA HW SET: 10 DESCRIPTION HINGE MANUAL FLUSH BOLT DUST PROOF STRIKE STOREROOM LOCK OH STOP SURFACE CLOSER KICK PLATE ASTRAGAL SILENCER FOR USE ON DOOR # 24 EACH TO HAVE: QTY DESCRIPTION 15 08 11 16 CATALOG NUMBER 7226 SET 7226 INT 4085 MS1850 X 4015 X 4016 20-013 114 4089 MS4000 9190HD-10"-NO SC81 SS SC80-30 SC80-61 8192AA 545A-MSLA-10 WEATHERSTRIP BY DOOR/FRAME MANUFACTURER CATALOG NUMBER 5BB1 4.5 X 4.5 W581P6 DANE SC81 REG 8400 10" X 2" LDW B -CS WS406/407CVX SR64 CATALOG NUMBER 5661 4.5 X 4.5 W301S DANE WS406/407CCV 188S -BK CATALOG NUMBER 5BB1 4.5 X 4.5 W101S DANE SC81 HDPA 8400 10" X 2" LDW B -CS WS406/407CVX 188S -BK 12 CATALOG NUMBER 5BB1 4.5 X 4.5 W101S DANE WS406/407CVX 1885 -BK 17B CATALOG NUMBER 5681 4.5 X 4.5 W51 1 P6 DANE WS406/407CCV 188S -BK CATALOG NUMBER 5BB1 4.5 X 4.5 NRP W581P6 DANE SC81 SS 8400 10" X 2" LDW B -CS 142A 188S -BK 8198AA 655A-MSLA-10 CATALOG NUMBER 5BB1 4.5 X 4.5 FB458 DP2 W561 P6 DANE 90S SR64 CATALOG NUMBER 5661 4.5 X 4.5 NRP FB458 DP2 W581P6 DANE 90S SC81 SS 8400 10" X 1" LDW B -CS 43SP SR64 17A 18 FINISH 626 626 628 628 626 626 630 689 689 689 AA A FINISH 652 626 689 630 630 GRY FINISH 652 626 630 S -BK FINISH 652 626 689 630 630 S -B K 21 FINISH 652 626 630 S -BK FINISH 652 626 630 S -B K FINISH 630 626 689 630 AL S -B K AA A FINISH 652 626 626 626 630 GRY FINISH 652 626 626 626 630 689 630 SP GRY 3/17/2016 MFR IVE IVE ADA ADA SCH ADA ADA IVE FAL FAL FAL ZER ZER MFR IVE FAL FAL IVE IVE IVE MFR IVE FAL IVE ZER MFR IVE FAL FAL IVE IVE ZER MFR IVE FAL IVE ZER MFR IVE FAL IVE ZER MFR IVE FAL FAL IVE ZER ZER ZER ZER MFR IVE IVE IVE FAL GLY IVE MFR IVE IVE IVE FAL GLY FAL IVE ZER IVE CATALOG NUMBER FINISH MFR HARDWARE BY DOOR / FRAME MANUFACTURER NEW DOOR TYPES TYPE: AA BB CC DD EE FF GG HH SIZE (W x H): 6'-0"x8'-0" 3'-0"x6'-8" 3'-0"x6'-8" 3'-O"x6'-8" 3'-0"x6'-8" 5'-0"x6'-8" 10'-0'x8'-0" 51-0"x6'-8" MAIN FLOOR , 3'-101/4" 6'-4" , 3'-101/4" 8'-O" AA STORE FRONT GLAZING ADD ALT. #3 -NO GLAZING -WOOD DOOR TEMP AL PAINTED HW -1 1 02 0 3'-O" 6'-8" d- .-- _. WOOD STAIN -- HM PAINTED HW -2 / \ / \ /// \\\ / \ / \ / \ I 1 \ /// 0 3'-O" 6'-8" BB WOOD STAIN -- HM PAINTED \ //i / / ,\ / \\\\ \ \ \ //// / / 0 3'-O" 6'-8" BB WOOD STAIN / \\\ \ HM % TEMP. HW -2 \ i�/ • / TEMP. 1 05 / \\\ \ \ 3'-O" \ �// / /TEMP. CC WOOD / GLAZING -- TEMP HM PAINTED n 1 O/ 0 TEMP. // \ \ \ \ DD \\ / / / % TEMP HM PAINTED HW -5 1 07 0 3'-O" 6'-8" BB WOOD STAIN -- 2'-1" PAINTED HW -3 1 08 0 3'-O" 6'-8" BB WOOD STAIN -- HM PAINTED HW -3 1 PANEL MAT'L STORE FRONT GLAZING WOOD WOOD / GLAZING WOOD / GLAZING PAINTED HM PAINTED HM GARAGE DOOR WOOD / GLAZING PANEL FINISH GLAZING PAINTED GLAZING GLAZING PAINTED PAINTED PAINTED GLAZING FRAME MATT A HM HM HM HM HM HM HM FRAME FINISH PAINTED PAINTED HM PAINTED HM PAINTED HM PAINTED HM PAINTED HM PAINTED HM PAINTED HM HARDWARE PAINTED HW -5 1 13 m 3'-O" QTY: 1 7 8 4 1 1 1 1 NEW DOOR SCHEDULE " • DOOR ID I SIZE TYPE MATT FINISH GLAZING FRAME HARDWARE NOTES QTY W HT MAIL FINISH SET NO KEYSIDE RM MAIN FLOOR 01 1.1 111 6'-O" 8'-O" AA STORE FRONT GLAZING -- TEMP AL PAINTED HW -1 1 02 0 3'-O" 6'-8" BB WOOD STAIN -- HM PAINTED HW -2 3/1 7/1 6 I 1 03 0 3'-O" 6'-8" BB WOOD STAIN -- HM PAINTED HW -3 1 04 0 3'-O" 6'-8" BB WOOD STAIN -- HM PAINTED HW -2 1 05 m 3'-O" 6-8" CC WOOD / GLAZING -- TEMP HM PAINTED HW -4 1 06 0 3'-0" 6'-8" DD WOOD / GLAZING -- TEMP HM PAINTED HW -5 1 07 0 3'-O" 6'-8" BB WOOD STAIN -- HM PAINTED HW -3 1 08 0 3'-O" 6'-8" BB WOOD STAIN -- HM PAINTED HW -3 1 09 m 3'-0" 6'-8" CC WOOD / GLAZING -- TEMP HM PAINTED HW -5 1 11 m 3'-0" 6'-8" CC WOOD / GLAZING -- TEMP HM PAINTED HW -5 1 12 0 3'-O" 6'-8" BB WOOD STAIN -- HM PAINTED HW -5 1 13 m 3'-O" 6'-8" CC WOOD / GLAZING -- TEMP HM PAINTED HW -6 1 14 0 3'-O" 6'-8" DD WOOD I GLAZING -- TEMP HM PAINTED HW -6 1 15 0 3'-O" 6'-8" 135 WOOD STAIN -- HM PAINTED HW -2 1 16 0 3'-0" 6'-8" CC WOOD / GLAZING -- 1 EMP HM PAINT ED—HW-6 1 17 m 3'-O" 6'-8" CC WOOD / GLAZING -- TEMP HM PAINTED HW -6 1 17A 0 3'-0" 6'-8" DD WOOD / GLAZING -- TEMP HM PAINTED HW -5 1 18 ID 3'-0" 6'-8" CC WOOD / GLAZING -- TEMP HM PAINTED HW -6 1 19 0 3'-O" 6'-8" EE PAINTED •M PAINTED -- HM PAINTED HW -7 1 20 m 5'-O" 6'-8" HH WOOD / GLAZING -- TEMP HM PAINTED HW -8 1 21 m 3'-O" 6'-8" CC WOOD / GLAZING -- TEMP HM PAINTED HW -5 1 22 0 3'-O" 6'-8" DP WOOD / GLAZING -- TEMP HM PAINTED HW -5 1 23 m 5'-0" 6'-8" FF PAINTED HM PAINTED -- HM PAINTED HW -9 1 24 /\1 10'-O" 8'-O" GG GARAGE DOOR PAINTED -- HM PAINTED HW -10 -1— NEW WINDOW TYPES NOTES: 1) PER ANSI A117.1-2009, ALL DOOR HARDWARE SHALL HAVE A SHAPE THAT I5 EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34 INCHES MINIMUM AND 48 INCHES MAXIMUM ABOVE THE FLOOR. 2) THE WOOD DOORS SHALL BE: VT INDUSTRIES "HERITAGE COLLECTION, PLAIN SLICED MAPLE WITH A CLEAR FINISH, BOOK MATCH [VENEER MATCH], RUNNING MATCH [ASSEMBLY MATCH]. 3) ALL GLAZING IN DOORS & WINDOWS SHALL BE TEMPERED. 4) ALL DOOR HARDWARE SPECIFICATIONS TO BE PEMKO - ALL DOORS TO BE ON A MASTER LOCK; COOR. WITH OWNER. Marker Text A B C D E SIZE (W x H): 2'-6"x6'-8" 13'x3'-8" 7'-6"x3'-8" 7'-6"x3'-8" 7'-6"x3'-8" 1/4" -1'-0" Sill Height 0' 3' 3' 3' 3' FRAME MAT'L HM HM HM HM HM FRAME FINISH PAINTED PAINTED PAINTED PAINTED PAINTED QTY: 1 1 1 1 1 it SEALANT, TYP EA SIDE WOOD DOOR, PER DOOR SCHEDULE INTERIOR HM DOOR JAMB DETAIL NOTE: ADC INTERIOR V\ A I) TO -2 FULL HEIGHT OWS. NO SILL HEIGHT BOXED OR BACK TO BACK HEADER W/ MIN (2) 6005200-33 JOISTS W/ WEB STIFFENERS @ EA SUPPORT SEALANT, TYP EA SIDE DOOR, PER DOOR SCHEDULE INTERIOR HM DOOR HEAD DETAIL Marker Text F G H J SIZE (W x H): 7'-6"x3'-8" 13'x3'-8" T -6"x3'-8" 71-6"x3'-8" 13'x3'-8" 1/4" - 1'-O" Sill Height 3' 3' 3' 3' 3' FRAME MAIL HM HM HM HM HM FRAME FINISH PAINTED PAINTED PAINTED PAINTED PAINTED QTY: 1 1 1 1 1 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 0 5 2016 ci City of Tukwila BUILDING DIVISION 10 RECEIVED CITY OF TU LA MAR 212016 PERMIT CENTER 4522 REGISTERED ARCHITECT \..„..1 . IN J. % THIS DOCUMENT REPRESENTS A PROPRIETARY DESIGN OWNED BY THE ARCHITECT AND SHALL NOT BE USED ON OTHER PROJECTS OR ADDITIONS TO THIS PROJECT OR FOR COMPLETION OF THIS PROJECT BY OTHERS EXCEPT BY PRIOR ARRANGEMENT IN WIRTING COPYRIGHT 0 10/13/10 BY BRODERICK ARCHITECTS, PLLC 1" X 4" BACK5PLASH WHERE I OCCURS SEE It IT. ELEVATIONS ' - -- - - ---• - LOCKING , - —rt.-- STAINLESS STEEL BACKPLATE I 1x MAPLE CAP 7,- I 16.003 PLOT DATE: 3/17/16 Alene Torossian 16.003 -Diecuts Printers- AC19.pin iNIERWAINE 3RODERICK ARCI I a NO. DATE DESCRIPTION i Ai CONTINUOUS 31/2" METAL STUD TRACK 1 ,r, -SINK AS 51--'ECIFIE-.:1? MAX a 1/2" /. STING STRUCTURE (NO CHANGE) EXISTING STRUCTURE w/ SCREWS @ 24" 0.C. (NO CHANGE) ILI .."•'' - * HI-LOW DRINKING FOUNTAIN 3/1 7/1 6 I I INTERIOR PARTITION: INTERIOR DETAILS & SCHEDULES A42 . 7/ Pre SiK1 COMPLYING WITH ANSI 602 ig VIF, I 2 x 4 STEEL STUDS 24" 0.C. WITH 5/8" TYPE X GWD EACH SIDE. I ..4. r — - lr .f---- KNEE SPACE REPUCEP TO 24" AT N. .r. J MOLD. ATTACH GWB PANELS TO TOP TRACK w/ SCREWS @ 12" 0.C. ;.-- 1;1 '-• ) - Ev - 30" COUNTER HEIGHTS PER ANSI 902.4.1.EXC 0 /7 - I -1 ---.‘ . :. ;:I- -, I I I I - 4g/ ./7 ..." Z.9 .er .7•-•." //7" 70/ .. f. //./.. ~W., / I, A 30" WIDE X 48" DEEP CLEAR ,-- .• SUSPENDED GRID CEILING 5 .• .. • .• • 8 1/2" SPOUT HT. .• . .• .• .. • GWB CEILING II s • , if & u r ›: Ili MOLDED VINYL TRAP COVER 30., SPACE SHALL BE MAINTAINED IN FRONT OF AND CENTERED ON THE LOW FOUNTAIN ,--__: ,---„,_ ' - • ' .• • .• .• .• BASE AS NOTED ON FINISH I I il : zI - PLAM OVER 1/4" PLYWOOD BACK BASE SEE FINISH SCHEDULE _ FF • . .• . •• • . . .. .: CONTINUOUS 3 112 METAL STUD TRACK -,-'-`, ---: CONTINUOUS 3 I/2" METAL STUD TRACK • . PLAN LEGEND .: .• ‘ ,--=--\ -„ _.,-, < „..---, ;-----:„ w/ SCREWS @ 24" O.C. MOLD. ATTACH GWE3 PANELS TO TOP TRACK :•• .-• .• • .• • • • : • :: :: ••• w/ SCREWS @ 24" 0.C. :. • MOLD. ATTACH GW B PANELS TO TOP TRACK .4. i z BARRIER. FREE KNEE SPACE -.--, ).-<'' >-<,--- J w/ SCREWS @ le O.C. - ....: . •• .:, .• —FLOORING AS NOTED ON FINISH FLOOR PLAN : .• .• • • • .• . .. •• .• .• • • :' J O.C. .• • .. •. • . • • .• •• INTERIOR PLUMBING PARTITION: • Il = SHOWN SHADED 1 1w/SCREWS12' >--c p----, il>-‹ 1 . t. 1 ..... _..... I ------ ' TYPICAL INTERIOR PARTITION: , n" ' . •-- / * • I ------1 ‘ :.--•-• _>--N :. ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED PARALLEL TO EACH SIDE OF 3 lie -- (Thi CAE3INET E5ASE WITH SINK 2 DRINKING FOUNTAIN .• .. • .• :• ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD .•.: APPLIED PARALLEL OR AT RIGHT ANGLES TO .• EACH SIDE OF 2 x 6 STEEL STUDS 24" D.C. WITH . ::>-<-- .• STEEL STUDS 24" 0.C. WITH 1" TYPS 5 DRYWALL SCREWS 8" O.C. AT EDGES AND 12" O.C. AT 5 PONY WALL DETAIL „..---K •:., ":---,-' .- --, :: :: .: INTERMEDIATE STUDS. JOINTS STAGGERED .. • 24" ON OPPOSITE SIDES. 4.2 -1,k.-14,/,.,.2.ffi=241,, '-0" '4 j•.2 1" = t-ou 4.2 1" = 1i-o" • .. 1" TYPS 5 DRYWALL SCREWS 8" O.C.T EDGES :. • • AND 12" 0.C. AT INTERMEDIATE STUDS. JOINTS ..• STAGGERED 24" ON OPPOSITE SIDES. .• :: :: - .. • .- .: --. •• OR - - -' -.`-' - II. :: - -2,-; .: :. I POP ATTACHMENT RIVET APPROVED METHOD .,- . - ' ... _. -- sil.'-' , „., n., 1 • ,.- , MAX > , t, , 1.,' , ''''''' „, ,- ' * , ,-, . 2" PERIMETER WALL --‹ . -- 1/2" SOLID SURFACE COUNTERTOP BASE AS NOTED ON FINISH PLAN LEGEND -- :: „---,„ "-----, • --- .. .:. _ ---- , ' - - SOUND BATT INSULATION LINE OF COUNTER BEYOND -• >--, ,,,,-----K :. --.. 1- ----1- - .,.--...,,,,:..,,-, ,..“..w ;- r ..,- -:,.I•I', , MOLDING TYP. ,,, - i' • ..3. /4'1•*'s ' ,-\ I ',,../- ".>„,...: 4 c- ,, '-',.%-.' STABILIZER BAR 1' ,),),.( . .. ,•=-I-‹ ( I UNDERMOUNT LAVATORY BEYOND ->---; ,,,,, u' •- t-----t , REDUCED KNEE SPACE AT ---- :. -.. .:'• I - • ., GRID ,'''''''' .. . " .,,,,/' , .., 4' 4'411% @ ATTACHED ,-- 2" `'.,., '''S. -,, *4 , • . s ••',. ' - WALL GRID 0 UNATTACHED WALL , . r -- -„ - 3 lir METAL STUD TRACK, ANCHORED TO FLOOR - • „,e i. ,-- ---..,1 !;_s____:,1 't-, U fi a, CHILDREN'S LAVATORY PER ANSI 902.4.1.EXC. 21.7" x 14.2" STEEL BRACKET -_, , , -. -, 4" RUBBER BASE _ • \ -7 -(11 A CV Z'7?KNAPE .e.: & VOGT KV20,5 OR EQUAL SEE ELEVATION FOR LOCATIONS > MOLDED VINYL TRAP COVER - • -,-.., > ' , - . • • —FLOORING AS NOTED ON FINISH FLOOR PLAN s't t •Zn ' ' • • • FLOORING A5 NOTED ON FINISH FLOOR PLAN GRID @ WALL NOTES: i . ..... __, • -i • NJ --; --_iv .... 1. GRID TO DE ATTACHED TO WALL ANGLE ON TWO ADJACENT WALLS i I PERIMETER SUPPORT 2. WALLS WITH UNATTACHED GRID TO HAVE 3/4" CLEARANCE BETWEEN RUNNER END AND PARTITION 1 WIRE @ EA. RUNNER ' 12 GAUGE HANGERS @ . INTERIOR WALL DETAIL 6 LAV DETAIL 3 PLUME5ING WALL DETAIL WALL ANGLE ,- , • ' "' •- - I 41-0" 0.C. EACH WAY ATTACH HANGERS TO STRUCTURAL FRAMING MEMBERS WITH 1/4"0 EYEBOLTS PENETRATING 11/4" I INTO STRUCTURE. 4.2 1 1/2= 1'-O"4.2 cD 1" = t-o" 4.2 1 1 /2"= 1'-O" PLASTIC LAMINATEOCCURS 1" X 4" BACKSPLASH WHERE - . .. .. ... 71-0" AFF . 24" SEE INT. ELEVATIONS FRT WOOD BACKING SYSEM OR 16 GA. SHEET STEEL BACKING, TYP. EASED EDGE - . •-- ,---,•„. r,,, • ''-`•-‘`-,-,-, •-- z- i 1/2"0 EMT A, , . - . - + FRT WOOD BACKING SYSEM OR - • 3/4" PLYWOOD 1 , 16 GA. SHEET STEEL BACKING, COUNTERTOP '• SEE , -- ..041%,„ , `<•-•```. ,COMPRESSION .:1:4';- ''' '' STRUT - - TYP. re ADV . '''..,'=" .4.;:::' ..1. • , 1 , ' . , . -, • .* '''' ,' , , ' -14arbs% ' - ' , . 2 ' r • , `-'• 1 „,,---.-',- I, 4'N's ) 1 • TYP. @ DIAGONAL i • BRACE: MAXI" SHORTER THAN WIRE STRUTS @ 121-0" 0.C. 1 - HEAVY DUTY .- 1x STAINED HARDWOOD - 1 ADJUSTABLE SHELVES ' .----- / Layl , ED9EBAND 7 34" UNLESS OTHERWISE NOTED EASED EDGE ON INTERIOR ELEVATIONS . . . . 44 , ' . • • r ..., „ UM ... DRAWER (WHERE OCCURS) CABINET PULL - VERIFY STYLE/ LOCATION ' :. Et!) . : n . ..._ - . . . ADJUSTABLE SHELF i i ' RECESSED SHELF STANDARDS - • PLAM OVER 1/4" PLYWOOD BACK ) 8 GANNET COUNTER DETAIL ,,;- s ,,--,,, '!„-; ..,7'•.„ 1 GENERAL CEILING ,',.. ` •I':,-,,.„ -,--,,,,,, ``‘,> -.- , ",, NOTES: •`,-- COMMERCIAL MAIN •••=---.-•,...-- : ' AND INTERMEDIATE , TEES ,•"' ''. 4 ' ,„:: :', - Ii•-•-•''-:' ''''---1--, `: , ' -'--- -• '','',,, , • 4 4 1-4---....J .. • ' 1 2x BASE FRAME 1 • . . 10 CABINET PULL - VERIFY STYLE/ ' ' _ RECESSED SHELF STANDARDS • [ 1 LOCATION . 4" BASE SEE FINISH SCHEDULE - A,- ,, - 4 - t -4111111111111111111111. 9 CASEWORK UPPER 35" 10 CASEWORK DASE CADINETS 4.2 1" = 1'—O" 4.3)1" = 11..O" 4.2 6" = 1'—O" 1. SUSPENDED CEILING 2. CEILINGS SHALL BE THROUGHOUT. : 1 3. HORIZONTAL SUPPORT THE MAIN RUNNER CEILING. THESE LATERAL I 4. VERTICAL SUPPORTS RUNNERS. DISCONTINUOUS DISCONTINUITIES, INCLUDING 5. CEILING AREAS OVER I 6. CEILINGS WITHOUT 7. CHANGES IN CEILING' 8. CABLE TRAYS AND 9. CONTRACTOR 15 RESPONSIBLE TO BE INSTALLED TO CISCA RECOMMENDATIONS FOR AREAS SUBJECT TO SEVERE SEISMIC ACTIVITY HORIZONTAL TO A TOLERANCE OF 1/8" IN 10'-O" MEASURED EACH WAY. GRID TO REMAIN A CONTINUOUS PATTERN I i SHALL BE PROVIDED BY FOUR WIRES MIN. NO.12 U.S. GAGE SPLAYED IN FOUR DIRECTIONS, 90° APART AND CONNECTED TO WITHIN 2" OF THE CROSS TEE AND TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45° FROM THE PLANE OF THE SUPPORTS SHALL BE PLACED 12'-O" 0.C. IN EACH DIRECTION, WITH THE FIRST POINT WITHIN 6'-O" FROM EACH WALL. I SHALL BE NO. 12 U.S. GAGE WIRE TO SUPPORT A MAXIMUM OF 16 SQUARE FEET OF CEILING AND SADDLE-TIED AROUND MAIN ENDS OF CROSS-RUNNERS AND MAIN RUNNERS TO DE VERTICALLY SUPPORTED WITHIN 8" OF CEILING• WALLS. i 2,500 SF MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITIONS RIGID BRACING MUST HAVE 2" OVERSIZED TRIM RINGS FOR SPRINKLERS AND OTHER PARTITIONS PLANE MUST HAVE POSITIVE BRACING 1 ELECTRICAL CONDUITS MUST BE INDEPENDENTLY SUPPORTED AND BRACED FOR COST AND COORDINATION OF SPECIAL INSPECTION IF REQUIRED BY LOCAL JURISTICTION REViEWED FOR CODE COMPLIANCE • - AN' PROVED . MAY 0 5 2016 . City of Tukwila BUILDING DIVISION I RECEIVED CITY OF TUI(W/LA MAR 2 1 2016 PERMIT CENTER 7 SUSPENDED CEILING 4.2 1" = 1 '-0" TYPICAL I DIECUT PRINTERS TENANT IMPROVEMENT 345 ANDOVER PARK EAST TUKWILA, WA #Site Postcode I I 16.003 PLOT DATE: 3/17/16 Alene Torossian 16.003 -Diecuts Printers- AC19.pin 3RODERICK ARCI I a NO. DATE DESCRIPTION I 3/1 7/1 6 I I INTERIOR DETAILS & SCHEDULES A42