Loading...
HomeMy WebLinkAboutPermit M16-0007 - STARBUCKS COFFEE COMPANY - DUCTLESS MINI SPLIT, STAND-ALONE STORAGE CONTAINERSTARBUCKS COFFEE COMPANY 3301 S NORFOLK ST EXPIRED 02/12/17 M16-0007 D.-PhCity of Tukwila one: Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0003400042 Permit Number: M16-0007 Address: 3301 S NORFOLK ST Issue Date: 2/1/2016 Address: 8840 152 AVE NE, REDMOND, WA, Permit Expires On: 7/30/2016 Project Name: STARBUCKS COFFEE COMPANY Owner: 2012 Name: 3301 SOUTH NORFOLK LLC Address: 12201 TUKWILA INTERNATIONAL BL, 98073-3550 SEATTLE, WA, 98168 Contact Person: 2012 Name: MAX FRANCIS Phone: (425) 881-3247 Address: 8840 152 AVE NE, REDMOND, WA, 2012 98052 2014 Contractor: 2012 Name: T E C MECHANICAL SERVICE CO Phone: (206) 881-3247 Address: P.O. BOX 3550, REDMOND, WA, 2012 98073-3550 2012 License No: TECMESC143BA Expiration Date: 2/1/2017 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL 12,000 BTU DUCTLESS MINI -SPLIT TO COOL STAND STAND-ALONE UNOCCUPIED STORAGE CONTAINER. ALL WORK SHALL COMPLY WITH 2012 WSMC/WSEC. ALL RELATED ELECTRICAL WORK SHALL BE PERMITTED BY A SEPARATE LICENSED ELECTRICAL CONTRACTOR Valuation of Work: $14,248.00 Fees Collected: $389.62 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Fuel type: ELECT Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2012 National Electrical Code: 2014 International Residential Code Edition: 2012 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2012 WAC 296-466: 2014 Uniform Plumbing Code Edition: 2012 WA State Energy Code: 2012 International Fuel Gas Code: 2012 Permit Center Authorized Signature: f t I Date: I I I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per it nd a o the conditions attached to this permit. Signature: Date: t6 Print Na! a Ct This permit sX1I become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is s1r6spencled or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, .cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Commiwni0i'Development Department ,Petillft Center 6300 Souti$center Blvd. Suite 100 TukwilA WA 98188 ft://www.Tukwi4aWA.gqy DaRB AppT#ioa Acoelte& l e Appfl;sff ` 13 ow;6 o)5qe use on?hy MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "please print" SITE LOCATION King Co Assessor's Tax No.: 0033400046 Site Address: 3301 S Norfolk Street Suite Number: Floor: Tenant Name: Starbucks Coffee Company New Tenant: ❑ .....Yes m..No PROPERTY OWNER Name: Starbucks Coffee Company Address: 2401 Utah Avenue S City: Seattle State: WA Zip: 98134 CONTACT PERSON — person receiving all project communication Name: Max Francis Address: 8840 152nd Avenue NE City: Redmond State: WA Zip: 98052 Phone: (425) 881-3247 Fax: Email: mfrancis@tecmechanical.com MECHANICAL CONTRACTOR INFORMATION Company Name: TEC Mechanical Address: 8840 152nd Avenue NE City: Redmond State: WA Zip: 98052 Phone: (425) 881-3247 Fax: ContrRegNo.: TECMESC143BA Exp Date: 02/01/2017 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 14,248 Describe the scope of work in detail: Install 12,00013TU/h ductless mini -split to cool stand-alone, unoccupied storage container. All work shall comply N%ith 2013 WSMC1WSEC. All related electrical NNork shall be permitted by a separate licensed electrical contractor. Use: Residential: New .......... ❑ Replacement ........ ❑ Commercial: New .......... m Replacement ........ ❑ Fuel Type: Electric..... m Gas....... ❑ Other:_ i I: Applications roans -Applications On I ine'2011 Applications vItchanical Permit Application Reused 8•o-11.d— Revised: August2011 bh Pace I of 2 Indicate typ"T meclmi&al woikbi�g installed andb"1009WY%� - _Unit Type - Qty Furnace <I 00k btu Furnace >I 00k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cool ing system Air handling unit <I0,000 cfm 1 Unif Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency enerator Other mechanical equipment Boiler/compressor Qty 0-3 hp/ 100,000 btu 1 3-15 h /500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Print Nance� Francis ing PO Box 3550 AGENT: Day Telephone Redmond Date: 01/04/2016 (425) 881-3247 W A QRf171 City State Zip 11:.1pplications�FurmrApplications On Line,201 I ApphcatiumAlechani-1 Prnna Applicatiun Rn, ixd 8-4-1 I.doc\ Ret iced: Aueust 2011 Page 2 of. Z bh DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $389.62 M16-0007 Address: 3301 S NORFOLK ST Apn: 0003400042 $389.62 MECHANICAL $374.63 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $267.20 PLAN CHECK FEE R000.322.102.00.00 0.00 $74.93 TECHNOLOGY FEE $14.99 TECHNOLOGY FEE TOTAL R000.322.900.04.00 0.00 $14.99 Date Paid: Wednesday, January 13, 2016 Paid By: TEC MECHANICAL SERVICE COMPANY Pay Method: CHECK 13902 Printed: Wednesday, January 13, 2016 3:04 PM 1 of 1 RSYS7EM5 INSPECTION RECORD Retain a copy with permit�� ? PECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: (rS Type of Inspection: M )tAA11 CAL /WA L Address: S Date Called: Special Instructions: Date Wantg,�l a. yv� 41f 16 P.m. Requester: Phone No: Inspector: r_� Date_116-46 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 6 - ��D(57 NSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permi ns ec ion RegEsl Line (206) 438-9350 Proje Type of Inspection: Ad es Date Called: Special Instructions: Q Date Wante a.m. 3 - 3 p.m. Requester: Phone No: F] Approved per applicable codes. Corrections required prior to approval. COMMENTS:-, �Yl ei y 1 �v te ptr'd A rd a wre-5-s-* /,5 d S C' Ci Inspector: Date: 3 �� r REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. •a 1 PROJECT INFORMATION DPD PROJECT NUMBER: PERMIT#: TENANT NAME: STARBUCKS 15560 BUILDING ADDRESS: 3301 S NORFOLK STREET, TUKWILA WA 98168 JURISDICTION: TUKWILA, KING COUNTY PARCEL NUMBER: 003340-0046 LOT SIZE: 13162 Q GROW TIMOTHY -DC 44 8 48 BEG NXN N LN OF S 130 FT OF SD DC 8 NELY MGN OF E HEATING MARGINAL WAY S TH S 22-32-30 E 73.70 FT ALG SO MGN TH N 67-27-30 E 82.87 Fr TH N LEGAL DESCRIPTION: 0019-11 E 34.22 FT TH S 8851-59 E 11.60 FT TH N 01-44-21 E 92.23 FT TO SELY MGN OF WEIGHT: S NORFOLK ST TH SWLY ALG SD MGN 145 FT TH SELY ALG NELY MGN OF E MARGINAL ELECTRICAL: WAY S 36.30 FT TO POB CFM: INSTALL 12,000BTU/H DUCTLESS MINI -SPLIT TO COOL STAND-ALONE, SCOPE OF WORK: UNOCCUPIED STORAGE CONTAINER. ALL WORK SHALL COMPLY WITH 2012 MODEL: WSMGWSEC. ALL RELATED ELECTRICAL WORK SHALL BE PERMITTED BY A EFFICIENCY: SEPARATE LICENSED ELECTRICAL CONTRACTOR .w'D FOR: 0 P�erbanical (�:ac.rical N-Piumbing lf.l,das Piping CW of Tukwila 5� SU11- IN G DIVISION EQUIPMENT SCHEDULE NOTES: ALL WORK SHALL COMPLY WITH 2012 WSEC / WSMC FILE COPY P,mrm1+ No _0007 2 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any =opteddordinance. Receipt of approvad i fieldns is acknowledged: UNIT 2 21 -9/32"x30 -23/32"x 11-13/32" ON VIBRATION—ISOLATION PADS AND SECURED TO THE CONCRETE WITH FOUR 6"CONCRETE ANCHORS (1 PER CORNER). NORTHEAST ELEVATION NORTHWEST ELEVATION SCALE: NONE [A— DOORS City of Tukwila BUILDING DIVISION Q COOLING HEATING HEAT COOLING NOISE: WEIGHT: DIMENSIONS: ELECTRICAL: MCA/ CFM: UNIT# SECTION: MAKE: MODEL: TYPE EFFICIENCY: EFFICIENCY: CAPACITY: CAPACITY will require a new plan sN 1 (H,W,D) �arj may inc3ude additional plan review fees. 1 MOCP: O 1 INDOOR PANASONIC CS-E12NKUAW HEAT PUMP 21 SEER 10.5 HSPF 14,100 BTU/H 10,200 BTU/H 40 dB(A) 20 lbs 11-7/16" x 34-9/32"x 208/230/60hz/1 ph 15/15 AMPS 1095 8-1/16" 2 OUTDOOR PANASONIC CU-E12NKUA HEAT PUMP 21 SEER 10.5 HSPF 14,100 BTU/H 10,200 BTU/H 46 dB(A) 82 lbs 21-9/32" x 30-23/32" 208/230/60hz/1 ph 15/15 AMPS N/A 11-13/32" NOTES: ALL WORK SHALL COMPLY WITH 2012 WSEC / WSMC FILE COPY P,mrm1+ No _0007 2 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any =opteddordinance. Receipt of approvad i fieldns is acknowledged: UNIT 2 21 -9/32"x30 -23/32"x 11-13/32" ON VIBRATION—ISOLATION PADS AND SECURED TO THE CONCRETE WITH FOUR 6"CONCRETE ANCHORS (1 PER CORNER). NORTHEAST ELEVATION NORTHWEST ELEVATION SCALE: NONE [A— DOORS --WOOD DECKING 0 GZ GZ � O ALL—INSULATED REFRIGERANT LINE SET OR PLAN NONE SCALE: NONE RECEIVED CITY OF TUKWILA DOORS rA— JAN 13 2016 N ROOF SCALE NONE 6111111111111. 07 PERMIT CENTER CORRUGATED METAL TOP REVIEWED FOR CODE COMPLIANG APPROVED JAN 2 1 2016 AT V4 City of Tukwila BUILDING DIVISIOt Co City of Tukwila BUILDING DIVISION Q DOOR LOCATIONS UNIT 1 1 I UNIT 2 I 1 1 I CONTAINER 2 AREA OF WORK STARBUCKS 9N REVISIONS a No changes shall by made to the scope ♦ ♦ Q of work without prior approval of SITE PLAN D �`t '4vtr fila Building Division. s will require a new plan sN 1 �arj may inc3ude additional plan review fees. 1 --WOOD DECKING 0 GZ GZ � O ALL—INSULATED REFRIGERANT LINE SET OR PLAN NONE SCALE: NONE RECEIVED CITY OF TUKWILA DOORS rA— JAN 13 2016 N ROOF SCALE NONE 6111111111111. 07 PERMIT CENTER CORRUGATED METAL TOP REVIEWED FOR CODE COMPLIANG APPROVED JAN 2 1 2016 AT V4 City of Tukwila BUILDING DIVISIOt Co Q N 00 0 4 C4 ,0 a CNI ♦ ♦ Q L / ,`1//\ U. ti M ti O O E00 M W o C4 SHEET TITLE: Project Information Site Plan Floor plan Equipment specifications M1/1 Panasonic ideas for life Split System Submittal Data Indoor: CS-E12NKUAW Outdoor. CU-E12NKUA Wall Mounted Heat Pump Job Name: Location: (BTU/H) Fan type Engineer: No. Speeds 5 Submitted to: 1300 Motor Output (W) Submitted by: CFM (Olo,Lo,Me,Hi,Shi) 187/246/335/425/472 Reference: 40 Coil Type Aluminum Power VIPH/Hz 2301208/1/60 Circuit Ampacity (A) 15 Fuse Size, Max. (A) 15 Compressor DC Rotary Inverter No. used Wired Remote Controller ( CZ-RD516C ) Optional 1 Output Power (W) 700 Outdoor Unit IC Thermostat Air Louver (Horizontal) Fan type (Vertical) Propeller Motor Type Built -In OC Motor ( 8 poles) Output Power (W) 40 AIrnOW CFM 1095 Coll Type lit Aluminum ( Blue Coated) Fin Type - Pipe Type Indoor Corrugated Fin Rows- F.P.I (Ibs.) 2-17 Face Area (sq.ft) 2.8 Indoor Unit (BTU/H) Fan type Cross Flow No. Speeds 5 RPM (High) 1300 Motor Output (W) 40 CFM (Olo,Lo,Me,Hi,Shi) 187/246/335/425/472 Indoor Sound Rating (Hi) (dB -A) 40 Coil Type Aluminum Fin & Copper Tube Fin Type - Pipe Type Slit Plate - Inner Rifled Rows - F.P.I 2.19 Face Area (sq.ft) 2 Drain Connection Size (in.) 518' Features Wireless Remote Controller Standard Line Size (in. O.D. Suction) Wired Remote Controller ( CZ-RD516C ) Optional 112" Controls Microprocessor Remote Controller LCD Wireless Type, Temp, Sensor Built In Temperature Control IC Thermostat Air Louver (Horizontal) Manual (Vertical) Automatic Power Failure Automatic Restart Built -In Self -Diagnosis Built -In Air Filter Washable, Anti -Mold Approval: Date: Construction: Unit #: Drawing #: Refrigerant (BTU/H) 10200 R410A Lbs. - R41 Oa (outdoor unit) 21 Dehumidification 2.16 Control Amps Electronic Expansion Valve Connection Power inputs (W) Flare Line Length, Max (ft.) (dB -A) 47 66 Lin Difference, Max (ft.) Indoor Dimensions Total Capacity 49 Line Size (in. O.D. Discharge) 1/4" Line Size (in. O.D. Suction) (A) 112" Dimensions (in.) Height Width Depth Indoor Unit (Unrated) 11-7/16" 349/32" 8.1/16" (Crated) o o Outdoor Unit (Unrated) 21-9/32" 30.23/32" 11-13/32" (Crated) lit Weight Indoor Outdoor Net (Ibs.) 20 82 Shipping (lbs.) Performance Data @ ARI Standard Conditions (230/208V) Cooling Total Capacity (BTU/H) 10200 SEER r, 00 0) 21 Dehumidification (Pints/H) 2.5 Amps (A) 3.5 Power inputs (W) 650 Outdoor Sound Rating (dB -A) 47 Heating Indoor Dimensions Total Capacity (BTU/H) 14100 HSPF 10.5 Amps (A) 6.1 Power inputs (W) 1150 Outdoor Sound Rating (dB -A) 46 Operating Range Indoor Air Intake Temp. Outdoor Air Intake Temp. Cooling Maximum 90F DB/74F WB 115F DB Minimum 6OF OB152F WS OF DB Heating Maximum 86F OB/ -F WB 75F DB/ 64F WB Minimum 60F OB/ -F WS 5F DB/ -F WB .ear•e w.. n 7-1 -> � t trs _ rre tit I. O ♦V .. uaw ve. U-5 ^ M Outdoor Dimensions LO W C spnaceccary wr <Top Vi ace r iR11 tabor, I I: 00 ..,a,_! 22A1..,ctrl S •� CU If acre U Ancnar Soft Pimh w /� 12518 x 22-112 9.way valve d Gu oaa \ V r i (t.ow Weaaxe) M cSgo VW— ■fin/• O - VJ O I� INITIALS It DRAFTED: CADDNW "Ix I DESIGNED: MF _ CHECKEG:I MF FVIEWED FOR R ITLE N C TITLEE COMPLIANCE RE EIVED APPROVED CITY 0 TUKWILA JAN 2 1 2016 JAN 13 2016 City of Tukwila PERMIT CENTER BUILDING DIVISION M 112 CU c.i • CU C) r, 00 0) ro Cl 4 C140 C4 X ♦ ♦ Ll / v 3: LOIT Indoor Dimensions � CY) .6 \ ,. -- - o o M V lit a. SHEET TITLE: +� j i I, S• Project Information - LM pYpMp MallN 34A Ripnt PpNp .ear•e w.. n 7-1 -> � t trs _ rre tit I. O ♦V .. uaw ve. U-5 ^ M Outdoor Dimensions LO W C spnaceccary wr <Top Vi ace r iR11 tabor, I I: 00 ..,a,_! 22A1..,ctrl S •� CU If acre U Ancnar Soft Pimh w /� 12518 x 22-112 9.way valve d Gu oaa \ V r i (t.ow Weaaxe) M cSgo VW— ■fin/• O - VJ O I� INITIALS It DRAFTED: CADDNW "Ix I DESIGNED: MF _ CHECKEG:I MF FVIEWED FOR R ITLE N C TITLEE COMPLIANCE RE EIVED APPROVED CITY 0 TUKWILA JAN 2 1 2016 JAN 13 2016 City of Tukwila PERMIT CENTER BUILDING DIVISION M 112 1/3/2017 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director MAX FRANCIS 8840 152 AVE NE REDMOND, WA 98052 RE: Permit No. M16-0007 STARBUCKS COFFEE COMPANY 3301 S NORFOLK ST Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 2/12/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 2/12/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r' V, Bill Rambo Permit Technician File No: M16-0007 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 0 Phone 206-431-3670 a Fax 206-431-3665 8/2/2016 City of Tukwila Allan Ekberg, Mayor Department of Community Development Jack Pace, Director MAX FRANCIS 8840 152 AVE NE REDMOND, WA 98052 RE: Permit No. M16-0007 STARBUCKS COFFEE COMPANY 3301 S NORFOLK ST Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/19/2016. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/19/2016, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley P Y Permit Technician File No: M 16-0007 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 9 Fax 206-431-3665 PERMIT COOR® COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M16-0007 DATE: 01/13/16 PROJECT NAME: STARBUCKS COFFEE COMPANY SITE ADDRESS: 3301 S NORFOLK ST X Original Plan Submittal Response to Correction Letter # DEPARTMENTS: /�T hwc, kXHO Building Division Public Works ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: APPROVALS OR CORRECTIONS: Approved ❑ Corrections Required ❑ (corrections entered in Reviews) Notation: REVIEWER'S INITIALS: Revision # before Permit Issued Revision # after Permit Issued AIA , ),)IA- H''Li-, P Fire Prevention 0 Planning Division ❑ Structural ❑ Permit Coordinator ❑ DATE: 01/14/16 Structural Review Required ❑ DATE: DUE DATE: 02/11/16 Approved with Conditions e Denied ❑ (ie: Zoning Issues) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 T E C MECHANICAL SERVICE Cq Page 1 of 2 HO]Tle Espanol Contact. Search L&I A -L Index Help My Secure L&I Safety & Health Claims & Insurance Workplace Rights Trades & Licensing Washington State Department of Labor & Industries T E C MECHANICAL SERVICE CO Owner or tradesperson Principals FRANCIS, CHARLES DOUGLAS, PRESIDENT BALDWIN, JOAN M, SECRETARY Doing business as T E C MECHANICAL SERVICE CO WA UBI No. 600 291 892 License PO BOX 3550 REDMOND, WA 98073-3550 425-881-3247 KING County Business type Corporation Governing persons C DOUGLAS FRANCIS JOAN M BALDWIN; Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ......................._............................... _............... Meets current requirements. License specialties GENERAL $1,000,000.00 License no. TECMESC143BA Effective — expiration Effective date 0110111986— 02/01/2017 03/28/2012 Bond ..._........... Expiration date AMERICAN STATES INS CO $12,000.00 Bond account no. 6350122 Received by L&I Effective date 05/23/2005 05124/2005 Expiration date Until Canceled Insurance ............................. Alaska National Insurance Co $1,000,000.00 Policy no. 12CPS08358 Received by L&I Effective date 03/19/2015 03/28/2012 Expiration date 03/28/2016 Insurance history Savings .................. No savings accounts during the previous 6 year period. Lawsuits against the bond or savings https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=600291892&LIC=TECMESC143BA&SAW= 01/26/2016