Permit EL16-1105 - CITY OF TUKWILA - MIDBLOCK CROSSING
CITY OF TUKWILA MIDBLOCK CROSSING 14400 TUKWILA INTERNATIONAL BLVD EL16-1105 City of Tukwila • Department of Community Development + 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov ELECTRICAL PERMIT Parcel No: 0040000180 Permit Number: EL16-1105 Address: 14400 TUKWILA INTERNATIONAL Issue Date: 12/9/2016 BLVD Permit Expires On: 6/7/2017 Project Name: CITY OF TUKWILA - MIDBLOCK CROSSING Owner: Name: TUKWILA CITY OF Address: 6200 SOUTHCENTER BLVD, TUKWILA, WA, 98188 Contact Person: Name: JON MOGENSEN Phone: (206) 595-6656 Address: 20111208TH AVE SE, RENTON, WA, 98058 Contractor: Name: WEST COAST SIGNAL INC Phone: (206) 595-6656 Address: 20111208TH AVE SE, RENTON, WA, 98058 License No: WESTCCS8928G Expiration Date: 11/21/2017 Lender: Name: Address: DESCRIPTION OF WORK: INSTALL NEW RAPID RESPONSE FLASHING BEACON AT THE EXISTING CROSSWALK APPROXIMATELY 500 FEET NORTH OF S 144TH STREET. SERVICE TO BE PROVIDED FROM EXISTING SERVICE AT THE NORTHWEST CORNER OF S 144TH ST TRAFFIC SIGNAL. Valuation of single family: $0.00 Fees Collected: $514.42 Valuation of mf/comm: $16,950.00 Type of Work: NEW Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer District: VALLEY VIEW Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-4613: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: G/i/ Date: l �� I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local,l�ws regulating construction or the performance of work. I am authorized to sign and obtain this development p mit and 4ree to the conditions attached to this permit. Signature:_ Print Name: Date: % 22— 5 -14 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: <NONE> PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2100 ELECTRICAL FINAL 7003 ROUGH -IN ELECTRICAL 7002 SERVICE 7001 UNDERGROUND/SLAB CITY OF TUKR7LA Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tukv.ilaWAgov SITE LOCATION Electrical Permit No. 9 L l � — l 10 Proj ect No. n n Date Application Accepted:! Date Application Expires: —_ use ELECTRICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" King Co Assessor's Tax No.: Site Address: 14400 Tukwila International Blvd, Tukwila Suite Number: Floor: Tenant Name: Tukwila Inter Blvd and S. 144th St Midblock Crossing New Tenant: ❑ .....Yes O .. No PROPERTY OWNER Name: City of Tukwila Address: 6300 Southcenter Blvd. City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: Jon Mogensen Address: 20111 208th Ave SE City: Renton State: WA Zip: 98058 Phone: (206) 595-6656 Fax: Email.. moge@westcoastsignal.com Valuation of Project (contractor's bid price): $ 16,950 ELECTRICAL CONTRACTOR INFORMATION Company Name: West Coast Signal, Inc. Address: 20111 208th Ave SE City: Renton State: WA Zip: 98058 Phone: (206) 595-6656 Fax: Contr Reg No.: WESTCCS8928C Exp Date: 11/21/2017 Tukwila Business License No.; BUS -0997246 Scope of Work (please provide detailed information): Install new Rapid Response Flashing Beacon at the existing crosswalk approximately 500 feet north of S . 144th St. Service to be provide from existing service at the northwest comer of S. 144th St traffic signal. Will service be altered? [Z] Yes ❑ No Type of Use: New RRFB Crosswalk service Tyne of work: 0 New ❑ Addition ❑ Service Change ❑ Low Voltage ❑ Generator ❑ Fire Alarm Property Served by: Puget Sound Energy ❑ Seattle City Light H:\4pplicationslForms-Applications On Line\2014 Applicatiom\Electrical Pennit _4pplication Revised 1-1-14.docx Revised: Jmnury 2014 bh Adding more than 50 amps? ❑ Remodel ❑ Telecommunication ❑ Yes m No ❑ Tenant Improvement ❑ Temporary Service Page 1 of 2 RESIDENTIAL NEW RESIDENTIAL SERVICE ❑ New single family dwellings ................................... $152.85 (including an attached garage) ❑ Garages, pools, spas and outbuildings ........................$81.90 ea ❑ Low voltage systems (alarm, furnace thermostat) ................................ $59.85 ea RESIDENTIAL REMODEL AND SERVICE CHANGES ❑ Service change or alteration ...................................... $81.90 (no added/altered circuits) ❑ Service change with addedlaltered circuits ................. $81.90 number of added circuits ....................... $11.55 ea ❑ Circuits added/altered without service change ........... $54.60 (up to 5 circuits) ❑ Circuits added/altered without service change ........... $54.60 (6 or more circuits) ............................................... $7.65 ea ❑ Meter/mast repair ....................................................... $68.25 ❑ Low voltage systems ................................................. $59.85 (alarm, furnace thermostat) PERMIT APPLICATION NOTES - MULTI -FAMILY AND COMMERCIAL Fees are based on the valuation of the electrical contract. MISCELLANEOUS FEES ❑ Temporary service (residential) ................................. $65.00 ❑ Temporary service (generator) ................................... $80.90 ❑ Manufacturedimobile home service ........................... $86.25 (excluding garage or outbuilding) ❑ Carnivals..................................................................-$80.60 Number of concessions ......................... $10.80 ea Each ride and generator truck ............... $10.80 ea ***EFFECTIVE JANUARY 1, 2014 EACH PERMIT WILL BE ASSESSED A 5% TECHNOLOGY FEE*** Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation The Building Official may grant one extension of time for an additional period not to exceed 90 days. The extension shall be requested in writing and justifiable cause demonstrated. I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Mailing Address: 20111 208tH Ave SE H_A4pplicatio=Tor Applications On Line\2014 Applicationc\Elearical Permit Application Revised 1-1-14.d— newsea: Tdna * DVI. bh Renton City Date: 12/02/2016 1e: (206) 595-6656 WA 98058 State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY ' $514.42 EL16-1105 Address: 14400 TUKWILA INTERNATIONAL BLVD Apn: 0040000180 $514.42 ELECTRICAL $494.63 PERMIT FEE MULTI-FAM/COMM R000.322.101.00.00 0.00 $395.70 PLAN CHECK FEE 11000.345.832.00.00 0.00 $98.93 TECHNOLOGY FEE $19.79 TECHNOLOGY FEE TOTAL111 R000.322.900.04.00 0.00 $19.79 Date Paid: Friday, December 09, 2016 Paid By: WEST COAST SIGNAL INC Pay Method: CHECK 6512 Printed: Friday, December 09, 2016 10:24 AM 1 of 1 CV SYSTEMS 5f Z INSPECTION RECORD rr� Retain a copy with permit �1�''��� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 DIVISION (206) 431-3670 Project: u Type of Inspection: Address: j Date Called: Special Instructions: Date Wanted: a.m. P.M. Requester: Phone No: 9 Approved per applicable codes. 1-1Corrections required prior to approval. IInspector: / 6 / A IDate: o I?,3 0 I F] REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with perm t 1 / INSPE ION N0. PERMIT No. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 U paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. f�Rf�Ei COORD COPY' PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: EL16-1105 DATE: 12/02/16 PROJECT NAME: CITY OF TUKWILA - MIDBLOCK CROSSING SITE ADDRESS: 14400 TUKWILA INTERNATIONAL BLVD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # DEPARTMENTS: �z PMC Building Division Fire Prevention Public Works ❑ Structural PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) Revision # after Permit Issued ❑ Planning Division ❑ ❑ Permit Coordinator to DATE: 12/06/16 Structural Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/03/17 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 V9 a x MAYOR ALLAN EKBERG DIRECTOR OF PUBLIC WORKS BOB GIBERSON, P.E. CITY ENGINEER ROBIN TISCHMAK, PE SCHEDULE OF DRAWINGS SHEET NO. SHEET TITLE 1 COVER SHEET 2 LEGEND, ABBREVIATIONS & DETAILS 3 ALIGNMENT AND CHANNELIZATION PLAN 4 RRFB SIGNAL PLAN 5 RRFB SIGNAL DETAILS ;'QUI � 01 FOR: t�Mect>;anicaf ❑ Electrical L�Plumbing MoGas Piping City of Tukwila P11 -D!, IG DIVISII CITY COUNCIL JOE DUFFIE, PRESIDENT KATHY HOUGARDY KATE KRULLER THOMAS McLEOD DE'SEAN QUINN DENNIS ROBERTSON VERNA SEAL REVISIONS No changes shall hn made to the Scope of work wltho14' prior approval of Ti:': "i'1 Eutding division. RQTC: i , s will reytaire a reiv plan submittal and may include additional plan review fees. HIELD COPT;: P*m" lin s This sOoloa nhudondors qqiflllww tkept at the site of wolk and shall be open to insW ion by the Btu OfIW j oradillyatdht dudreps�eser +e. City Of TuWla BUILDING DIVISION b } +ENGINEERING •STREETS *WATER*SEWER*BUU DING * date wt83KIPCv' IM InterdisciplinaryDesign Mo 3131Dc+lke 42lesfna.A is %aws T,mMWANO -W- selw.wkw2l Rom ---- OMAN ow.41M REVIEWED FUH COMPLIANCE WITH NFPA 70 b NEC I10 DEC 02 2016 PERMIT CENTER TUKWILA INTERNATIONAL BLVD & BID S 144TH ST MIDBLOCK CROSSING DOCUMENT COVER SHEET W LJ } F v 1 5 no 160MV.Dwe EXISTING LEGEND t N;, GUARD POST D CATCH BASIN 0 SEWER MANHOLE -0- UTIUTY POLE r?. - o STREET LIGHT (LUMINAIRE) JUNCTION BOX m GAS VALVE ® WATER VALVE Q WATER MANHOLE A FIRE HYDRANT A SIGN ca SHRUB r9 MONUMENT IN CASE P-------_ POWER so- - STORM SEWER r. GAS w WATER �--- RAILING - — A • GUARDRAIL i * CONCRETE ROCKERY CONCRETE RETAINING WALL PROPOSED LEGEND t- CONCRETE ti= CSTC ASPHALT CONCRETE DETECTABLE WARNING SURFACE MANHOLE ACP ASPHALT CONCRETE PAVEMENT HMA MONUMENT IN CASE STORM DRAIN INLET PROTECTION —o-- SILT FENCE ABBREVIATIONS AC ASPHALT CONCRETE MH MANHOLE ACP ASPHALT CONCRETE PAVEMENT MIC MONUMENT IN CASE ADA AMERICANS HATH DISABILITIES ACT MON MONUMENT APPROX APPROXIMATE N NORTH OR NORTHING co CATCH BASIN NAVD NORTH AMERICAN VERTICAL DATUM CCP CEMENT CONCRETE PAVEMENT NO NUMBER CDF CONTROLLED DENSITY FILL NTS NOT TO SCALE CHIJc CHAINUNK PVC POLYVINYL CHLORIDE OR q CENTERLINE ROW RIGHT OF WAY CL CLASS RT RIGHT CO CLEANOUT OR COUNTY S SLOPE OR SOUTH COL COLUMN SD STORM DRAIN CONC CONCRETE SDMH STORM DRAIN MANHOLE CSBC CRUSHED SURFACING BASE COURSE SE SOUTHEAST (STC CRUSHED SURFACING TOP COURSE SS SANITARY SEWER DI DUCTILE IRON SSMH SANITARY SEWER MANHOLE DIA DIAMETER ST STREET E EAST OR EASING STA STATION EA EACH STD STANDARD ELEV ELEVATION SW SOUTHWEST EDP EDGE OF PAVEMENT TYP TYPICAL EW EACH WAY VERT VERTICAL EXIST EXISTING W WEST FO FIBER OPTIC YD YARD DRAIN FOC FACE OF CURB HMA HOT MIX ASPHALT HORIZ HORIZONTAL ID INSIDE DIAMETER IE INVERT ELEVATION IN INCH/INCHES JB JUNCTION BOX L LENGTH LT LEFT IF LINEAR FEET LP LOW POINT MAX MASIUM MIN MINIMUM t 3 1' SEE PLAN DIM OR MATCH DOSING IMSTING PAVEJAENT Ij `�MAX - ` d 1 ;ih t i .sox n" rrl MT 4" CEMENT CONCIffTE SDEWALK SAWCUT PER PLAN, SHEET 3 NOTES - 1. WHERE INDICATED ON PLANS, SIDEWALK RAMPS SHALL MEET ADA STANDARDS 4' CSTC WSDOT STD PLAN F-30.10-03 '�-IPROPOSiD CDAENT CONCRETE TRAFFIC CURB & GUTTER PER WSDOT STD v� PLAN F-10.11-03 -2" CSTC —COMPACTED SUBGRADE HMA CLASS 1/Y PG 64-22 MATCH DOSING PAVEMENT THICKNESS TYPICAL CONCRETE SIDEWALK SECTION NTS REVIEWED 1 -UH COMPLIANCE WITH NFPA 70 - NEC DEC 0 6 2016 RECEIVED CITY OF TUKWILA DEC 02 2016 City of Tukwila PERNiff CENTER BUILDING DIVISION L �4 d! of mii F u a Do IM TUKWILA INTERNATIONAL BLVD & I 9118 InwdIWpIIrwyD"lp BID S 144TH ST MIDBLOCK CROSSING -"` s ;ENGINEERING*STREETS*WATER*SEWER*BUILDING* ItAt*fto" 9ns + 11-waso DOCUMENT , lowsNIXINK • , dEr m O LEGEND, ABBREVIATIONS & DETAILS acxle ras field bk no u; wmm no dak teviaioos IdW SlFO2011; fp TUKIIVILA INTERNATIONAL BLVD 4' ^i ;�; °5RpleAX 4• IN At.l • • � [ LEVEL LANDING DETAIL NTS Q S.s 8.2` _ 4,0', VARIES, SEE PLAN :•' -t• � SEE RI TRANSITION PANEL DETAIL NTS X12 $ f J ter° °!• �f .TN.:- ' V......_ ..a.�' 6)µl ,cj Q c� mmm t 7 f ' •:� ✓' 12 1 5.5, I4.0 0' 6.6' L1 PLAN HMA OVERLAY TO BE 0 5 10 20 " FLUSH WITH PAVEMENT, SCALE IN !FEET � � , [ L" ' ,- SEAL JOINT WITH AR4000 l C 2056 ASPHALT PATCH DETAIL NTS GENERAL NOTES 1. CONTRACTOR TO VERIFY ALL U71UTY LOCATIONS 2 PRESERVE AND PROTECT EXISTING CATCH BASINS CONSTRUCTION NOTES O1 SAWCUT AND REMOVE EXISTING CURB, GUTTER, AKD SIDEWALK AS NECESSARY TO INSTALL NEW CONCRETE CURB, GUTTER AND SIDEWALK, SEE TYPICAL CONCRETE SIDEWALK SECTION. SHEET 2 OINSTALL NEW CEMENT CONCRETE CURB RAMP PER WSDOT STANDARD PLAN F-40.15-02 QINSTALL DETECTABLE WARNING SURFACE PER WSDOT STANDARD PLAN F-45.10-01. REPLACE JUNCTION BOX PER SIGNAL PLAN AND DETAILS, SHEETS 4 AND 5. ©INSTALL PEDESTRIAN SIGNAL POLE PER SIGNAL PLAN AND DETAILS, SHEETS 4 AND 5. ©REMOVE IN ROAD FLASHERS. PATCH HOLE PER ASPHALT PATCH DETAIL. THIS SHEET. REMOVE EXISTING TREE. rJ8 PROTECT ElOS11NG TREE. O9 INSTALL TEMPORARY SILT FENCE PER WSDOT STD PLAN 1-30.15-02 10 INSTALL STORM DRAIN INLET PROTECTION PER WSDOT STD PLAN I--40.2()-DO 11 PROVIDE 4 -FT BY 44T LEVEL LANDING IN AT THE PEDESTRIAN SIGNAL POLE, SEE DETAIL, THIS SHEET. 12 INSTALL TRANSITION PANEL FROM LEVEL LANDING TO EX GRADE, SEE DETAIL, THIS SHEET. CHANNELIZATION NOTES 24' THERMOPLASTIC CROSSWALK LINE PER CITY OF TUKWJ.A STANDARD PLAN RS -19 J12' THERMOPLASTIC CROSSWALK LINE PER CITY OF TUKWILA STANDARD PLAN RS -19 R yI"WW17LU, DEC 02 2010 HMA CI1/2• 84-22 [AlI ]EV CSTC MINN q �'� "� PZJ�LI 'ViTO .�,5 Z7►.�FT_ K •ENGINEERING*STREETS*WATER*SEWER*BUIIDING* oy Is�a •Q by I date C,� IntardlaelpllnmyDesgn 3131DWAve 2�1NaPesmAss s�1,4>� 1e�a,WA93w2 $%%WA63121 (l33►6274120 (M)al%o �"'�`�' BID DOCUMENT TUKWILA INTERNATIONAL BLVD & S 144TH ST MIDBLOCK CROSSING 4.5' VARIES, SEE PLAN :•' -t• � SEE RI TRANSITION PANEL DETAIL NTS X12 $ f J ter° °!• �f .TN.:- ' V......_ ..a.�' 6)µl ,cj Q c� mmm t 7 f ' •:� ✓' 12 1 5.5, I4.0 0' 6.6' L1 PLAN HMA OVERLAY TO BE 0 5 10 20 " FLUSH WITH PAVEMENT, SCALE IN !FEET � � , [ L" ' ,- SEAL JOINT WITH AR4000 l C 2056 ASPHALT PATCH DETAIL NTS GENERAL NOTES 1. CONTRACTOR TO VERIFY ALL U71UTY LOCATIONS 2 PRESERVE AND PROTECT EXISTING CATCH BASINS CONSTRUCTION NOTES O1 SAWCUT AND REMOVE EXISTING CURB, GUTTER, AKD SIDEWALK AS NECESSARY TO INSTALL NEW CONCRETE CURB, GUTTER AND SIDEWALK, SEE TYPICAL CONCRETE SIDEWALK SECTION. SHEET 2 OINSTALL NEW CEMENT CONCRETE CURB RAMP PER WSDOT STANDARD PLAN F-40.15-02 QINSTALL DETECTABLE WARNING SURFACE PER WSDOT STANDARD PLAN F-45.10-01. REPLACE JUNCTION BOX PER SIGNAL PLAN AND DETAILS, SHEETS 4 AND 5. ©INSTALL PEDESTRIAN SIGNAL POLE PER SIGNAL PLAN AND DETAILS, SHEETS 4 AND 5. ©REMOVE IN ROAD FLASHERS. PATCH HOLE PER ASPHALT PATCH DETAIL. THIS SHEET. REMOVE EXISTING TREE. rJ8 PROTECT ElOS11NG TREE. O9 INSTALL TEMPORARY SILT FENCE PER WSDOT STD PLAN 1-30.15-02 10 INSTALL STORM DRAIN INLET PROTECTION PER WSDOT STD PLAN I--40.2()-DO 11 PROVIDE 4 -FT BY 44T LEVEL LANDING IN AT THE PEDESTRIAN SIGNAL POLE, SEE DETAIL, THIS SHEET. 12 INSTALL TRANSITION PANEL FROM LEVEL LANDING TO EX GRADE, SEE DETAIL, THIS SHEET. CHANNELIZATION NOTES 24' THERMOPLASTIC CROSSWALK LINE PER CITY OF TUKWJ.A STANDARD PLAN RS -19 J12' THERMOPLASTIC CROSSWALK LINE PER CITY OF TUKWILA STANDARD PLAN RS -19 R yI"WW17LU, DEC 02 2010 HMA CI1/2• 84-22 [AlI ]EV CSTC MINN q �'� "� PZJ�LI 'ViTO .�,5 Z7►.�FT_ K •ENGINEERING*STREETS*WATER*SEWER*BUIIDING* oy Is�a •Q by I date C,� IntardlaelpllnmyDesgn 3131DWAve 2�1NaPesmAss s�1,4>� 1e�a,WA93w2 $%%WA63121 (l33►6274120 (M)al%o �"'�`�' BID DOCUMENT TUKWILA INTERNATIONAL BLVD & S 144TH ST MIDBLOCK CROSSING 3 filOtt01049A3C3,.DWG • V."0 ImsIMPa &wn %13 WAS drxt<d WAX116 • Nta OVn6 ALIGNMENT AND CHANNELIZATION PLAN .& fieldbkno ,s�»s' s�rF 2A1s A Y 'o' LEGEND EXISTING DESCRIPTION O ROADWAY LUMINAIRE O SIGNAL POLE WITH DUAL MAST ARMS O DECORATIVE PEDESTRIAN LUMINAIRE 3 PER WSDOT STD DET J-21.10 AC POWERED RRFB ASSEMBLY AND POLE f- POLE/MAST ARM MOUNTED SIGN JAL. POST MOUNTED SIGN IN -ROADWAY WARNING LIGHTS CONTROLLER Ct"I`- CABINET 0 IN -ROADWAY WARNING LIGHT JUNCTION BOX TYPE 1, & 2 — - - - — CONDUIT Q WARE NOTE O CONSTRUCTION NOTE O SIGN NOTE O POLE NOTE - —_—; GENERAL NOTES I. ALL WORK SHALL BE IN ACCORDANCE WTH THE WSDOT/APWA STANDARD PLANS, STANDARD SPECIFICATIONS, CITY OF TUKWILA »2i5C�'-f STANDARDS AND THESE PLANS AND SPECIAL PROVISIONS. s 2 THE CONTRACTOR SHALL CONTACT THE CITY REPRESENTATIVE TIN KIRKLAND AT (206) 433-1860 FOR ALL REQUIRED COORDINATION WITH THE CITY OF TUKWILA TRAFFIC OPERATIONS AND SIGNAL MAINTENANCE DEPARTMENT. 3. THE LOCATION OF ALL FEATURES TO BE INSTALLED BY THE CONTRACTOR SHALL BE VMFIED IN FIELD BY THE ENGINEER PRIOR TO INSTALLATION. 4. CONDUIT LOCATION IS SHOWN FOR REFERENCE ONLY. CONDUIT SHALL BE PLACED UNDER NEW SIDEWALK WHERE PRACTICABLE 6. ALL NEW JUNCTION BOXES INSTALLED IN SIDEWALKS SHALL HAVE LOCKING, NON-SKID UDS. 7. ALL HOLES FOR EXISTING OR NEW POLES SHALL BE COLD GALVANIZED. CONSTRUCTION NOTES O CONSTRUCT ONE FOUNDATION, AND INSTALL ONE RRFB POLE AND BASE ASSEMBLY. INSTALL ONE RRFB APS STYLE PEDESTRIAN PUSH BUTTON, ONE RRFB LIGHT BAR. ONE CONTROLLER CABINET AND SIGNS ON THE POLE PER RRFB SCHEDULE, THIS SHEET, AND SIGNALJZATION DETAILS, SHEET 5. COORDINATE ORIENTATION OF RRFB APS STYLE PEDESTRIAN PUSH BUTTON WITH THE ENGINEER PRIOR TO INSTALLATION. SEE SPECIAL PROVISIONS. CONSTRUCT ONE FOUNDATION. AND INSTALL ONE RRFB POLE AND BASE ASSEMBLY. INSTALL ONE RRFB APS STYLE PEDESTRIAN PUSH BUTTON, ONE RRFB LIGHT BAR, AND SIGNS ON THE POLE PER RRFB SCHEDULE, THIS SHEET, AND SIGNALZATION DETAILS, SHEET 5. COORDINATE ORIENTATION OF RRFB APS STYLE PEDESTRIAN PUSH BUTTON WITH THE ENGINEER PRIOR TO INSTALLATION. SEE SPECIAL PROVISIONS. O EXISTING SIGNAL POLE WITH DUAL MAST ARM TO REMAIN. REMOVE ALL EXISTING SIGNS FROM POLE AND MAST ARM, PUSH BUTTON, CABINET, SOLAR PANEL, AND UNUSED EXISTING WHIG. PLUG UNUSED HOLES AND COLD GALVANIZE INSTAL. TWO RRFB LIGHT BARS, ONE RRFB APS STYLE PEDESTRIAN PUSH BUTTON WITH 12' EXTENSION, AND SIGNS ON THE POLE AND INSTALL ONE SIGN ON EACH MAST ARIA PER RRFB SCHEDULE. THIS SHEET, AND SIGNAUZAIION DETAILS, SHEET 5. O REMOVE EXISTING SIGN AND REPLACE PER THE SIGN SCHEDULE, THIS SHEET. INSTALL THREE SIDED RETROREFLECTIVE POST STRIPPING. SEE SPECIAL PROVISIONS. O REMOVE EXISTING IN -ROADWAY WARNING LIGHT AND ASSOCIATED CONDUIT AND WIRING. SEE ALIGNMENT AND CHANNEUZATION PLAN FOR PAVDHENT RESTORA710K © REMOVE EXISTING TYPE PPB SIGNAL POLE AND ALL ASSOCIATED EQUIPMENT, CONDUIT, AND WIRING. SALVAGE PER SPECIAL PROVISIONS —_ O REMOVE AND REPLAN EXISTING JUNCTION BOX WITH NEW JUNCTION BOX WITH NON -SUP LOCKING UD. PROTECT EXISTING MIRING AND CONDUIT TO REMAIN. t�8 INSTALL NEW CONDUIT AND COMPLETE WIRING PER N1RE NOTES PROTECT EXISTING WRING AND CONDUIT TO REMAIN. Og EXISTING ELECTRICAL SERVICE CABINET LOCATED ON THE NW CORNER OF TUKWILA INTERNATIONAL BLVD ! S 1447H ST, APPROXIMATELY 300' SOUTH. CONTRACTOR SHALL INSTALL WRING TO EXISTING ELECTRICAL SERVICE. CITY OF TUKWILA SHALL COMPLETE TERMINATIONS FOR 120V CIRCUIT IN EXISTING ELECTRICAL SERVICE CABINET. - RRFB SCHEDULE PLAN SIGN SCHEDULE 0 5 10 20 30 SCALE IN FEET KUL FON RRFB DETAILS SEE SHEET 5. • REVIEWED .FOR H COMPLIAN WITH ��PA %� - NEC AHEAD DEC 0 6 2016 00 o© W11-2 (38' x 361, W11-2 (36' x 36') W16 -9P (24' x 12') City of Tukw-lla T GNS ARE NOT TO SCALE. Q DSNSAFLUORESCENT NEEEN _AG DIVISI-. GN DIMENSIONS SHALL BE VERIFIED THE ENGINEER AND MANUFACTURER PRIOR CALL TO FABRICATION. BEFORE YOU DIG 4. EACH NEW SIGN ASSEMBLY SHALL INCLUDE 12' x 12' ORANGE FLAG (RETROREFLECTIVE -80 1 424.5555 SHEETING). LOCATED AT THE TOP OF THE ASSEMBLY AND ORIENTED AT 45' TO FLAG AS NEW SIGN. RRFB f LOCATION PEDESTRIAN VERIFICATION LIGHTS *FOUNDATION TYPE 1 FIELD LOCATE WITH ENGINEER ONE SIDED, FACE CROSSWALK 3 PER WSDOT STD DET J-21.10 2 EX TWO SIDED 8 EXISTING 3 FIELD LOCATE WTH ENGINEER I ONE SIDED, FACE CROSSWALK 3 PER WSDOT SID DET J-21.10 +INCLUDES PEDESTRIAN VERIFICATION LIGHTS A Cf3il®rI• MAINKul OK���d 1..4 iALL NEW CONDUIT SHAH BE PVC SCH 80. 2. ALL CONDUITS CONTAINING CONDUCTORS SHALL INCLUDE GROUND WIRE. GROUND WIRE SIZE SHALL MATCH THE LARGEST CONDUCTOR (MIN /8 AWG OR AS NOTED OTHERWISE IN THE WIRE NOTES). CONDUITS THAT DO NOT CONTAIN ELECTRICAL CONDUCTORS SHALL INCLUDE A DETECTABLE PULL TAPE AND SHALL BE LABELED 'CITY OF TUKWILA'. RECEIVED CITY OF TUKWILA DEC 02 2016 PERMIT CENTER of i F } F I by I date TUKWILA INTERNATIONAL BLVD & P U.B.LIC WQRKS DEPT _ � BAc osne Kh'G 4 BID S 144TH ST MIDBLOCK CROSSING q � 08116 Interti�cipllnary Design 5 n *ENGINEERING *STREETS *WATER*SEWER*BUILDING* cbecked JC WAs 3191Eke6Are &Hie<ro JT'-Z_Asi� DOCUMENT file n01600SG01,DWG o�n6 sawkwA95121 Rs3)6nm26 RRFB SIGNAL PLAN a* I, -2t 190 w dir (206)2661610 wtw#gaxl - - - - field bk no no date reyWolx 1 date S9''TEIBER 2016, W11-2 AND W16 -7P SIGNS SHALL BE FLORESCENT YFILOW—GREEN TYPE IX RETROREFLECTIVE SURFACE ONE RRFB CONTROLLER CABINET (RRFB /1 HEIGHT SHE ONLY). MOUNTING ALL 8DETERMINED IN THE FIELD WITH THE ENGINEER PRIOR TO DRILLING HOLES ONE W11-2 SIGN 36'x38'. MOUNT AS DIRECTED BY THE ENGINEER IN THE t=. ---- ONE RECTANGULAR RAPID FLASHING BEACON (RRFB) LIGHT BAR WITH PEDESTRIAN VERFICAMON LIGHT. MOUNT AS DIRECTED BY THE ENGINEER IN THE FRD. SEE SPECIAL ONE W16 -7P SIGN 2412", MOUNT AS DIRECTED BY THE ENGINEER IN THE FIELD. 1'' ONE PEDESTRIAN WARNING SIGN 12-x12'. MOUNT AS DIRECTED BY THE ENGINEER N THE FIELD. FOR SIGN DETAILS, SEE THIS SHEET.-- RRFB APS STYLE PEDESTRIAN PUSH BUTTON WITH PEDESTRIAN SIGN, MOUNT AS DIRECTED BY ENGINEER IN THE FIELD. SEE SPECIAL PROVISIONS. FOR SIGN DETAILS, SEE THIS SH#:Ei:--- 4 - 8 NPT METAL PGE WITH THREADED BOTTOM. SNE SPECIAL PROVISIONS. MATCH BOX -TYPE SUP FIT BREAKAWAY METAL BASE NTH HANDHOIE. THREADED TO ACCEPT 4' - B NPT METAL POLE. FOR BOLT CIRCLE, SEE THIS SHEET. SEE SPECIAL PROVISIONS TOP OF FOR FOUNDATION DETAILS SEE WSDOT STD PLAN J-21.10.— 0 "N' o' o of 1h .o fi BACK TO BAC( W11-2 SO WK36'. MOUNT AS DIRECTED BY THE ENGINEER IN THE FIELD. - RECTANGULAR RAPID FLASHING BEACON (RRFB) LIGHT BAR WITH PEDESTRIAN VERIFICATION LIGHT. MOUNT AS DIRECTED BY THE ENGINEER IN THE FIELD. SEE SPECIAL PROVISIONS, - W16 -7P SIGN 2402', MOUNT AS DIRECTED BY THE ENGINEER IN THE FIELD. ---- PEDESTRIAN WARNING SIGN lfx12'. MOUNT AS DIRECTED BY THE ENGILEER N THE FIELD, FOR SIGN DETAILS, SEE THIS SHEET. - MATCH z" -F ------- T, (4) 3Ni' ANCHOR BOLTS, SEE SPECIAL PROVISIONS. FOR REINFORCING SEE WSDOT STI) PLAN J-21.10 AC POWERED RRFS ASSEMBLY DETAIL NTS 12' SO CROSS TRAFFIC MAY NOT STOP USE CAUTION WHEN CROSSING PEDESTRIAN WARNING SIGN DETAILS NTS NOTE SIN SHALL HAVE BLACK LEGEND NTH YELLOW SIGN WINDBAR AND BACKGROUND. POLE BANDING (TYP) ' PUSH BUTTON TO 2v TURN ON WARNING UGHTS PEDESTRIAN PUSH BUTTON SIGN DETAILS NTS NOTE: SIGN SHALL HAVE BLACK LEGEND WITH WHITE BACKGROUND. TWO, BACK TO BACK, WI1-2 SIGN 36'x36'. MOUNT AS DIRECTED BY THE ENGINEER IN THE FIELD.— TWO, BACK TO BACK, RECTANGULAR RAPID FLASHING BEACON (RRFB) LIGHT BAR WITH PEDESTRIAN VERIFICATION LIGHT. MOUNT AS DIRECTED BY THE ENGINEER IN THE FIELD. SEE SPECIAL PROVISIONS. TWO, BACK TO BACK, W16 -7P SIGN 24x12-, MOUNT AS DIRECTED BY THE ENGINEER N THE FIELD, ONE PEDESTRIAN WARNING SIGN 12'427. MOUNT AS DIRECTED BY THE ENGINEER IN THE FIELD. FOR SIGN DETAILS, SEE THIS SHEET.— RRFB APS STYLE PEDESTRIAN PUSH BUTTON WITH PEDESTRIAN SIGN, MOUNT AS DIRECTED BY ENGINEER N THE FIELD. SEE SPECIAL PROVISIONS. FOR SIGN DETAILS, SEE THIS SHEET — 1n a<4 j 13.75' SO RRFB BOLT CIRCLE NTS DIRECTION OF TRAFFIC CURB AND SIDEWALK 270'— r EGEQ. 1. HANDHOLE ACCESS DOOR SHALL BE MOUNTED AT 90' 2. SIGN ORIENTATION PER THE PLANS REVIEWED i-uh COMPLIANCE WITH NFPA 70 a NEC DEC 0 6 2016 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 02 2016 TOP OF CURB ;� PERMIT CENTER TOP OF SIDEWALK M' ca01a POLE FRONT NEW (FACING SOU� '��� AC POWERED RRFB ASSEMBLY ON EXISTING DUAL MAST ARM SIGNAL POLE DETAIL tip NTS Q F 11 k d* TUKWILA TUKWILA INTERNATIONAL BLVD & _�_�-_�_ ,� `' " P TSL. Z�i ." '+C7� 5 T�► P`T'_ 1e ml : P+Cw"k 5 9 *4" me ins IntWiscIplVagDesign BID S 144TH ST MIDBLOCK CROSSING •ENGINEERING+STREETS*WATER+SEWER*Bdxakal JG 0lrK® 3aiFaottne UILDING«1421*"A* 5 e CDRNM una &* 4m T.ua.,WAwm filen ieoaeSORDIN '• d'u ''�' DOCUMENT Mm= RRFB SIGNAL DETAILS Scale NTS field bkco (Neilesae4o xxw.I9oao 110 deie teviaiom Idate SHETiNIEtt2at6, WEST COAST SIGNAL INC Washington State Department of Labor & Industries WEST COAST SIGNAL INC Owner or tradesperson Principals SHERWOOD, ROGER P, PRESIDENT Mogensen, Becky, PRESIDENT UNITED STATES CORP AGENTS INC, AGENT MOGENSEN, JON E, PRESIDENT (End: 11/13/2015) Doing business as WEST COAST SIGNAL INC Home Espanol Contact. Safety & Health Page 1 of 2 Search L&I � — -�I ;1! A -Z Index Help My L &I Claims & Insurance Workplace Rights Trades & Licensing 20111 208TH AVE SE RENTON, WA 98058 206-595-6656 KING County WA UBI No. Business type 603 149 602 Corporation Governing persons JON ERIC MOGENSEN ROGER PAUL SHERWOOD; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor Active. ................................................. Meets current requirements. License specialties GENERAL License no. WESTCCS8928G Effective — expiration 11/2112011-11/21/2017 Designated administrator Active. REED, STEVEN J Meets current requirements. License type License no. Master Electrician REED`SJ972N5 Bond Contractors Bonding & Insurance Co $4,000.00 Bond account no. SJ4016 Received by L&I Effective date 11/07/2011 11/0712011 Expiration date Until Canceled .Savings ................ No savings accounts during the previous 6 year period. License Violations .......................................... https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=603149602&LIC=WESTCCS8928G&SAW= Help us improve 12/8/2016