HomeMy WebLinkAboutPermit PG16-0135 - BLAIRE RESIDENCE - WATER REPIPEB RE RESIDENCE
4424 S 156 ST
PG16-0135
City of Tukwila
• Department of Community Development
• 6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
PLUMBING/GAS PIPING PERMIT
Parcel No: 8108600060
Address: 4424 S 156TH ST
Project Name: BLAIRE RESIDENCE
Owner:
Name: WALKER ANNE & BLAIR KERRY
Address: 4424 S 156TH ST, TUKWILA, WA,
Address: 175A ROY RD SW #101, PACIFIC, WA,
98047
License No: RESCUR*007Q7
Lender:
Name:
Address: , , ,
DESCRIPTION OF WORK:
FRESH WATER RE -PIPE (1 BATH)
Permit Number: PG16-0135
Issue Date: 9/14/2016
Permit Expires On: 3/13/2017
Phone: (206) 730-0914
Phone: (253) 872-4902
Expiration Date: 1/1/2018
Valuation of Work: $15,108.00 Fees Collected: $222.29
Water District: HIGHLINE
Sewer District: NONE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
98188
Contact Person:
2014
Name:
JONATHON FARRELL
Address:
175 A ROY RD SW, PACIFIC, WA,
International Mechanical Code Edition:
98047
Contractor:
2014
Name:
RESCUE ROOTER
Address: 175A ROY RD SW #101, PACIFIC, WA,
98047
License No: RESCUR*007Q7
Lender:
Name:
Address: , , ,
DESCRIPTION OF WORK:
FRESH WATER RE -PIPE (1 BATH)
Permit Number: PG16-0135
Issue Date: 9/14/2016
Permit Expires On: 3/13/2017
Phone: (206) 730-0914
Phone: (253) 872-4902
Expiration Date: 1/1/2018
Valuation of Work: $15,108.00 Fees Collected: $222.29
Water District: HIGHLINE
Sewer District: NONE
Current Codes adopted by the City of Tukwila:
International Building Code Edition:
2015
National Electrical Code:
2014
International Residential Code Edition:
2015
WA Cities Electrical Code:
2014
International Mechanical Code Edition:
2015
WAC 296-46B:
2014
Uniform Plumbing Code Edition:
2015
WA State Energy Code:
2015
International Fuel Gas Code:
2015
Permit Center Authorized Signature: 6 114111 Date:
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:hc—
Print Name:
Date: 9 /
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS***
2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
3: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and
the Fuel Gas Code.
S: No portion of any plumbing system or gas piping shall be concealed until inspected and approved.
6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and
Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of
the holder of the permit to make sure that the work will stand the test prescribed before giving notification
that the work is ready for inspection.
7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall
unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes
installed outside the conditioned space shall be insulated to minimum R-3.
8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing
shall be protected by steel nail plates not less than 18 guage.
9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No
plumbing piping shall be directly embedded in concrete or masonry.
10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected
in accordance with the requirements of the building code.
11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin
layers to twelve inches above the top of the piping with clean earth, which shall not contain stones,
boulders, cinderfill, frozen earth, or construction debris.
12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or
an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other
ordinance of the jurisdiction.
13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit.
14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of
plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies
that use significant quantities of water shall comply with Washington States Water Efficiency ad
Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section
402 of Washington State Amendments
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
2000 GAS PIPING FINAL
8004 GROUNDWORK
1900
PLUMBING FINAL
9002
ROUGH -IN GAS PIPING
8005
ROUGH -IN PLUMBING
9001
UNDERGROUND
CITY OF TUKff 1
Community Development Department
Permit Center
• 6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
Iiitp://www.Tukwi]aWA.Q�
SITE LOCATION
Plumbing/Gas Permit No.0
Project No.
Date Application Accepted:
Date Application Expires:
For office use onl q
PLUMBING / GAS PIPING PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
"Please Print"
fA King Co Assessor's Tax No.:
Site Address: y y z y S M-& St/%i,,,,Ila 9$% BSuite Number: Floor:
Tenant Name: oiic/ / ,fit" eflr/l' New Tenant: ❑..... Yes El. -No
PROPERTY OWNER
Name: n17
y
Address: /7
e -/z
City: /, State: �v� Zipgg
w l
CONTACT PERSON - person receiving all project
communication
Name: /
Gr
Address:
City: /17 State, Zip:9ga y
7
Phone: Z6 (o 736 - b9/ Lf
Fax:
Email:
PLUMBING CONTRACTOR INFORMATION
Company Name:
P r u P
Address:
z J
City: P `/ State:
/1.1111 Zip:
04
Phone: 25-3-0-)1 L1��/
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
* oo-7 Q-1
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):,> h
Building Use (per Int'l Building Code):
Occupancy (per Int'l Building Code):
Utility Purveyor: Water:
H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Sewer:
Pagel of 2
Indicate type of plumbing fixtures and/o. s piping outlets being installed and the quantl.- ,elow:
Fixture Type
Qty
Bathtub or combination
bath/shower
Dishwasher, domestic with
independent drain
Q
Shower, single head trap
Sinks
Z
Rain water system — per
drain (inside building)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Each additional medical
gas inlets/outlets greater
than 5
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
-z
Fixture Type
Qty
Bidet
Drinking fountain or water
cooler (per head)
Lavatory
Urinal
Water heater and/or vent
Repair or alteration of
water piping and/or water
treatment equipment
Backflow protective device
other than atmospheric -
type vacuum breakers 2
inch (51 mm) diameter or
smaller
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections over 5
-z
PERMIT APPLICATION NOTES -
Fixture Type
Qty
Clothes washer,
domestic
Food -waste grinder,
commercial
Wash fountain
Water closet
Industrial waste
treatment interceptor,
including trap and vent,
except for kitchen type
grease interceptors
Repair or alteration of
drainage or vent piping
Backflow protective
device other than
atmospheric -type
vacuum breakers over 2
inch (51 mm) diameter
-z
Gas piping outlets
Fixture Type
Qty
Dental unit, cuspidor
Floor drain
Receptor, indirect waste
Building sewer and each
trailer park sewer
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity
Medical gas piping
system serving 1-5
inlets/outlets for a specific
gar
Each lawn sprinkler
system on any one meter
including backflow
protection devices
� l►os� b� bs
-z
Value of Construction — In all cases; a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing
and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR A
Print Name:iL
Mailing Address:
H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 l.docx
Revised: August 2011
bh
Date: 4
Day Telephone: ZS`3—g 7?
City
State Zip
Page 2 of 2
DESCRIPTIONS
PermitTRAK
PAID
$442.27
PG16-0135 Address: 4424 S 156TH ST
Apn: 8108600060
$222.29
PLUMBING
$211.70
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$179.20
TECHNOLOGY FEE
$10.59
TECHNOLOGY FEE
R000.322.900.04.00
0.00
$10.59
PG16-0136 Address: 16203 45TH AVE S
Apn: 9314900150
$219.98
PLUMBING
$209.50
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
0.00
$32.50
PERMIT FEE
R000.322.100.00.00
0.00
$177.00
TECHNOLOGY FEE
$10.48
TECHNOLOGY FEE
RECEIPT:TOTAL FEES PAID BY • i$442.27
R000.322.900.04.00
0.00
$10.48
Date Paid: Wednesday, September 14, 2016
Paid By: RESCUE ROOTER
Pay Method: CHECK 9226008385
Printed: Wednesday, September 14, 2016 12:30 1 of 1 07
SYSTEMS
PM
INSPEI
Retain a
INSPECTION NO.
:TION RECORD
13
copy with permit a
PERMITT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd.., #100, Tukwila. WA 981 (206) 431-3670
Permit Inspection Request Line (206) 438-9350 _ /1f
Pr ect:
TypHf Inspection: ,�
,�fC
P1g i- A, T"lAAL
Address:
Date Called:
1-141 0'/-N Si'
Special Instructions:
/m.
Date Wantevlq//0"p.m.
Requester:
�U /J
Phone No:
-V2-l73q
rA Approved per applicable codes. a Corrections required prior to approval.
COMMENTS:
Inspector: Date:
1/j 9 j9
REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
RESCUE ROOTER
Home Espafiol Contact
Safety & Health Claims & Insurance
Washington State Department of
Labor & Industries
RESCUE ROOTER
Owner or tradesperson
965 RIDGE LAKE BLVD.
SUITE 201
Principals
MEMPHIS, TN 38120
SUGGS, DONALD
253-872-4902
KEITH, PARTNER/MEMBER
KARNES, DONALD K, PARTNER/MEMBER
SLOTT, DAVID M, MANAGER
MCMAHON, JAMES T, MANAGER
LEBARON, WILLIAM E, PARTNER/MEMBER
(End: 01/21/2003)
BECKMANN,ROBERT
F, PARTNER/MEMBER
(End: 02/11/2002)
HARDING, BRIAN, PARTNER/MEMBER
(End: 04/10/2009)
DUPLESSIS, CARL, PARTNER/MEMBER
(End: 04/10/2009)
BOREN, HOWARD, PARTNER/MEMBER
(End: 10/09/2006)
ZALIK, STAN, PARTNER/MEMBER
(End: 10/09/2006)
BUREL, MARK T, PARTNER/MEMBER.
(End: 10/09/2006)
MEYERS, GARY, PARTNER/MEMBER
(End: 10/09/2006)
HANKS, JOSEPH B, PARTNER/MEMBER
(End: 10/29/2003)
PETERSON, CHRIS, PARTNER/MEMBER
(End: 10/29/2003)
FAZIO, FRED JR, PARTNER/MEMBER
(End: 10/29/2003)
MARIANO, LAWRENCE L
III, PARTNER/MEMBER
(End: 12/27/2001)
BATES, BRUCE A, PARTNER/MEMBER
(End: 12/27/2001)
Doing business as
RESCUE ROOTER
WA UBI No. Business type
601 837 949 Limited Liability Company
Parent company Governing persons
AMERICAN RESIDENTIAL SRVC LLC BILL
as]I1.Lr
Page 1 of 4
Search L&I ``�j rf
A -L Index I telp My L1;:I
Workplace Rights Trades & Licensing
Help us improve
https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601837949&LIC=RESCUR*007Q7&SAW= 9/14/2016