Loading...
HomeMy WebLinkAboutPermit PG16-0135 - BLAIRE RESIDENCE - WATER REPIPEB RE RESIDENCE 4424 S 156 ST PG16-0135 City of Tukwila • Department of Community Development • 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov PLUMBING/GAS PIPING PERMIT Parcel No: 8108600060 Address: 4424 S 156TH ST Project Name: BLAIRE RESIDENCE Owner: Name: WALKER ANNE & BLAIR KERRY Address: 4424 S 156TH ST, TUKWILA, WA, Address: 175A ROY RD SW #101, PACIFIC, WA, 98047 License No: RESCUR*007Q7 Lender: Name: Address: , , , DESCRIPTION OF WORK: FRESH WATER RE -PIPE (1 BATH) Permit Number: PG16-0135 Issue Date: 9/14/2016 Permit Expires On: 3/13/2017 Phone: (206) 730-0914 Phone: (253) 872-4902 Expiration Date: 1/1/2018 Valuation of Work: $15,108.00 Fees Collected: $222.29 Water District: HIGHLINE Sewer District: NONE Current Codes adopted by the City of Tukwila: International Building Code Edition: 98188 Contact Person: 2014 Name: JONATHON FARRELL Address: 175 A ROY RD SW, PACIFIC, WA, International Mechanical Code Edition: 98047 Contractor: 2014 Name: RESCUE ROOTER Address: 175A ROY RD SW #101, PACIFIC, WA, 98047 License No: RESCUR*007Q7 Lender: Name: Address: , , , DESCRIPTION OF WORK: FRESH WATER RE -PIPE (1 BATH) Permit Number: PG16-0135 Issue Date: 9/14/2016 Permit Expires On: 3/13/2017 Phone: (206) 730-0914 Phone: (253) 872-4902 Expiration Date: 1/1/2018 Valuation of Work: $15,108.00 Fees Collected: $222.29 Water District: HIGHLINE Sewer District: NONE Current Codes adopted by the City of Tukwila: International Building Code Edition: 2015 National Electrical Code: 2014 International Residential Code Edition: 2015 WA Cities Electrical Code: 2014 International Mechanical Code Edition: 2015 WAC 296-46B: 2014 Uniform Plumbing Code Edition: 2015 WA State Energy Code: 2015 International Fuel Gas Code: 2015 Permit Center Authorized Signature: 6 114111 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature:hc— Print Name: Date: 9 / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***PLUMBING/GAS PIPING PERMIT CONDITIONS*** 2: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 3: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 4: All plumbing and gas piping systems shall be installed in compliance with the Uniform Plumbing Code and the Fuel Gas Code. S: No portion of any plumbing system or gas piping shall be concealed until inspected and approved. 6: All plumbing and gas piping systems shall be tested and approved as required by the Plumbing Code and Fuel Gas Code. Tests shall be conducted in the presence of the Plumbing Inspector. It shall be the duty of the holder of the permit to make sure that the work will stand the test prescribed before giving notification that the work is ready for inspection. 7: No water, soil, or waste pipe shall be installed or permitted outside of a building or in an exterior wall unless, adequate provision is made to protect such pipe from freezing. All hot and cold water pipes installed outside the conditioned space shall be insulated to minimum R-3. 8: Plastic and copper piping running through framing members to within one (1) inch of the exposed framing shall be protected by steel nail plates not less than 18 guage. 9: Piping through concrete or masonry walls shall not be subject to any load from building construction. No plumbing piping shall be directly embedded in concrete or masonry. 10: All pipes penetrating floor/ceiling assemblies and fire -resistance rated walls or partitions shall be protected in accordance with the requirements of the building code. 11: Piping in the ground shall be laid on a firm bed for its entire length. Trenches shall be backfilled in thin layers to twelve inches above the top of the piping with clean earth, which shall not contain stones, boulders, cinderfill, frozen earth, or construction debris. 12: The issuance of a permit or approval of plans and specifications shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the Plumbing Code or Fuel Gas Code or any other ordinance of the jurisdiction. 13: The applicant agrees that he or she will hire a licensed plumber to perform the work outlined in this permit. 14: All new plumbing fixtures installed in new construction and all remodeling involving replacement of plumbing fixtures in all residential, hotel, motel, school, industrial, commercial use or other occupancies that use significant quantities of water shall comply with Washington States Water Efficiency ad Conservation Standards in accordance with RCW 19.27.170 and the 2006 Uniform Plumbing Code Section 402 of Washington State Amendments PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 2000 GAS PIPING FINAL 8004 GROUNDWORK 1900 PLUMBING FINAL 9002 ROUGH -IN GAS PIPING 8005 ROUGH -IN PLUMBING 9001 UNDERGROUND CITY OF TUKff 1 Community Development Department Permit Center • 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 Iiitp://www.Tukwi]aWA.Q� SITE LOCATION Plumbing/Gas Permit No.0 Project No. Date Application Accepted: Date Application Expires: For office use onl q PLUMBING / GAS PIPING PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. "Please Print" fA King Co Assessor's Tax No.: Site Address: y y z y S M-& St/%i,,,,Ila 9$% BSuite Number: Floor: Tenant Name: oiic/ / ,fit" eflr/l' New Tenant: ❑..... Yes El. -No PROPERTY OWNER Name: n17 y Address: /7 e -/z City: /, State: �v� Zipgg w l CONTACT PERSON - person receiving all project communication Name: / Gr Address: City: /17 State, Zip:9ga y 7 Phone: Z6 (o 736 - b9/ Lf Fax: Email: PLUMBING CONTRACTOR INFORMATION Company Name: P r u P Address: z J City: P `/ State: /1.1111 Zip: 04 Phone: 25-3-0-)1 L1��/ Contr Reg No.: Exp Date: Tukwila Business License No.: * oo-7 Q-1 Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information):,> h Building Use (per Int'l Building Code): Occupancy (per Int'l Building Code): Utility Purveyor: Water: H:\Applications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Sewer: Pagel of 2 Indicate type of plumbing fixtures and/o. s piping outlets being installed and the quantl.- ,elow: Fixture Type Qty Bathtub or combination bath/shower Dishwasher, domestic with independent drain Q Shower, single head trap Sinks Z Rain water system — per drain (inside building) Grease interceptor for commercial kitchen (>750 gallon capacity) Each additional medical gas inlets/outlets greater than 5 Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) -z Fixture Type Qty Bidet Drinking fountain or water cooler (per head) Lavatory Urinal Water heater and/or vent Repair or alteration of water piping and/or water treatment equipment Backflow protective device other than atmospheric - type vacuum breakers 2 inch (51 mm) diameter or smaller Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 -z PERMIT APPLICATION NOTES - Fixture Type Qty Clothes washer, domestic Food -waste grinder, commercial Wash fountain Water closet Industrial waste treatment interceptor, including trap and vent, except for kitchen type grease interceptors Repair or alteration of drainage or vent piping Backflow protective device other than atmospheric -type vacuum breakers over 2 inch (51 mm) diameter -z Gas piping outlets Fixture Type Qty Dental unit, cuspidor Floor drain Receptor, indirect waste Building sewer and each trailer park sewer Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity Medical gas piping system serving 1-5 inlets/outlets for a specific gar Each lawn sprinkler system on any one meter including backflow protection devices � l►os� b� bs -z Value of Construction — In all cases; a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one extension of time for an additional period not to exceed 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 International Plumbing Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR A Print Name:iL Mailing Address: H:Wpplications\Forms-Applications On Line\2011 Applications\Plumbing Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh Date: 4 Day Telephone: ZS`3—g 7? City State Zip Page 2 of 2 DESCRIPTIONS PermitTRAK PAID $442.27 PG16-0135 Address: 4424 S 156TH ST Apn: 8108600060 $222.29 PLUMBING $211.70 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $179.20 TECHNOLOGY FEE $10.59 TECHNOLOGY FEE R000.322.900.04.00 0.00 $10.59 PG16-0136 Address: 16203 45TH AVE S Apn: 9314900150 $219.98 PLUMBING $209.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $32.50 PERMIT FEE R000.322.100.00.00 0.00 $177.00 TECHNOLOGY FEE $10.48 TECHNOLOGY FEE RECEIPT:TOTAL FEES PAID BY • i$442.27 R000.322.900.04.00 0.00 $10.48 Date Paid: Wednesday, September 14, 2016 Paid By: RESCUE ROOTER Pay Method: CHECK 9226008385 Printed: Wednesday, September 14, 2016 12:30 1 of 1 07 SYSTEMS PM INSPEI Retain a INSPECTION NO. :TION RECORD 13 copy with permit a PERMITT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila. WA 981 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 _ /1f Pr ect: TypHf Inspection: ,� ,�fC P1g i- A, T"lAAL Address: Date Called: 1-141 0'/-N Si' Special Instructions: /m. Date Wantevlq//0"p.m. Requester: �U /J Phone No: -V2-l73q rA Approved per applicable codes. a Corrections required prior to approval. COMMENTS: Inspector: Date: 1/j 9 j9 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. RESCUE ROOTER Home Espafiol Contact Safety & Health Claims & Insurance Washington State Department of Labor & Industries RESCUE ROOTER Owner or tradesperson 965 RIDGE LAKE BLVD. SUITE 201 Principals MEMPHIS, TN 38120 SUGGS, DONALD 253-872-4902 KEITH, PARTNER/MEMBER KARNES, DONALD K, PARTNER/MEMBER SLOTT, DAVID M, MANAGER MCMAHON, JAMES T, MANAGER LEBARON, WILLIAM E, PARTNER/MEMBER (End: 01/21/2003) BECKMANN,ROBERT F, PARTNER/MEMBER (End: 02/11/2002) HARDING, BRIAN, PARTNER/MEMBER (End: 04/10/2009) DUPLESSIS, CARL, PARTNER/MEMBER (End: 04/10/2009) BOREN, HOWARD, PARTNER/MEMBER (End: 10/09/2006) ZALIK, STAN, PARTNER/MEMBER (End: 10/09/2006) BUREL, MARK T, PARTNER/MEMBER. (End: 10/09/2006) MEYERS, GARY, PARTNER/MEMBER (End: 10/09/2006) HANKS, JOSEPH B, PARTNER/MEMBER (End: 10/29/2003) PETERSON, CHRIS, PARTNER/MEMBER (End: 10/29/2003) FAZIO, FRED JR, PARTNER/MEMBER (End: 10/29/2003) MARIANO, LAWRENCE L III, PARTNER/MEMBER (End: 12/27/2001) BATES, BRUCE A, PARTNER/MEMBER (End: 12/27/2001) Doing business as RESCUE ROOTER WA UBI No. Business type 601 837 949 Limited Liability Company Parent company Governing persons AMERICAN RESIDENTIAL SRVC LLC BILL as]I1.Lr Page 1 of 4 Search L&I ``�j rf A -L Index I telp My L1;:I Workplace Rights Trades & Licensing Help us improve https:Hsecure.Ini.wa.gov/verify/Detail.aspx?UBI=601837949&LIC=RESCUR*007Q7&SAW= 9/14/2016