Loading...
HomeMy WebLinkAboutPermit D17-0250 - AT&T - AWNINGAT&T 16415 SOUTHCENTER PKWY Dl 7-0250 Parcel No: Address: 0 City of Tukwila 0 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov 5379200290 DEVELOPMENT PERMIT 16415 SOUTHCENTER PKWY Project Name: AT&T Permit Number: D17-0250 Issue Date: 10/11/2017 Permit Expires On: 4/9/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: ARGUS GROUP/BDS SARM 10500 NE 8TH ST STE 1930 , BELLEVUE, WA, 98004 LUKE WALKER 18375 OLYMPIC AVE S TUKWILA, WA, 98188 RAINIER INDUSTRIES LTD 18375 OLYMPIC AVS , TUKWILA, WA, 98188 RAINI IL066QP SUE BUXBAUM 10500 NE 8TH ST, STE 850 , BELLEVUE, WA, 98004 Phone: (425) 981-1214 Phone: (425) 251-1800 Expiration Date: 1/11/2019 DESCRIPTION OF WORK: 1 WEDGE AWNING @ 84 LINEAL FEET X 36" TALL X 24" DEEP Project Valuation: $17,050.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: Electrical Service Provided by: TUKWILA Fees Collected: $795.96 Occupancy per IBC: Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 Permit Center Authorized Signature: It/ A I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development peymit and agree to theonditions attached to this permit. Signature: Print Name: Date: /04/777 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center, 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 8: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 9: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 10: Truss shop drawings shall be provided with the shipment of trusses delivered to the job site. Truss shop drawings shall bear the seal and signature of a Washington State Professional Engineer. Shop drawings shall be maintained on the site and available to the building inspector for inspection purposes. 11: Structural Observations in accordance with I.B.C. Section 1709 is required. At the conclusion of the work included in the permit, the structural observer shall submit to the Building Official a written statement that the site visits have been made and identify any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 4046 SI-EPDXY/EXP CONC 4004 SI -WELDING CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 11 7 cT),12j0 Project No. Date Application Accepted: Ott (1 Date Application Expires: 9211\ (For office se only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 16415 Southcenter Parkway Tenant Name: AT&T PROPERTY OWNER Name: Luke Walker Name: SARM Enterprises City: Tukwila State: WA Zip: 98188 Address: 10500 NE 8th St Suite 1930 Email: lukew@rainier.com City: Bellevue State: WA Zip: 98004 CONTACT PERSON — person receiving all project communication Name: Luke Walker Address: 18375 Olympic Ave S City: Tukwila State: WA Zip: 98188 Phone: (425) 981-1214 Fax: Email: lukew@rainier.com GENERAL CONTRACTOR INFORMATION Company Name: Rainier Industries Address: 18375 Olympic Ave S City: Tukwila State: WA Zip: 98188 Phone: (42 5) 251-1800 Fax: Contr Reg No.: RAINIIL066QP Exp Date: 10/01/2017 Tukwila Business License No.: BUS -0100320 H:1Applicatiose\Fours-Applications On Line1201 1 ApplicatiotsTermit Application Revised . 8.9-I I.docs Revised: August 2011 bh King Co Assessor's Tax No.: 5379200290 Suite Number: Floor: New Tenant: ❑ Yes J „No ARCHITECT OF RECORD Name: Sue Buxbaum Company Name: Rainier Industries Company Name: Engineer Name: Thomas Swanson Architect Name: City: Tukwila State: WA Address: Phone: (425) 981-1214 Fax: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Sue Buxbaum Company Name: Rainier Industries City: Bellevue State: WA Zip: 98004 Engineer Name: Thomas Swanson Address: 18375 Olympic Ave S City: Tukwila State: WA Zip: 98188 Phone: (425) 981-1214 Fax: Email: thomass@rainier.com LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Sue Buxbaum Address: 10500 NE 8th St Suite 850 City: Bellevue State: WA Zip: 98004 Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 17,050 Describe the scope of work (please provide detailed information): 1 wedge awning @ 84 lineal feet x 36" tall x 24" deep Will there be new rack storage? ❑ Yes Existing Building Valuation: $ 1,191,300 Z.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fomes-Applications On Line1201 I Applications\Permit Application Revised - 8-9-I I.doea Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per . IBC Type of Occupancy per IBC 1st Floor 4,636 2"d Floor 3'd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport • Detached Carport Covered Deck .. Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If `yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fomes-Applications On Line1201 I Applications\Permit Application Revised - 8-9-I I.doea Revised: August 2011 bh Page 2 of 4 Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O)'NER.OR AUTHORIZED AGENT: Signature: 27iti4en„ Print Name: 1_ L4, Kt Wit ( Ker Mailing Address: I g 37 S 61y ""� r Avt 5 H:\Applications\Fours-Applications On Line\201 I Applications\Permit Application Revised - 8-9-I I.does Revised: August 2011 bh Date: Day Telephone:t1LS q1'/ —/2 T '1t Wig lig)d City State Zip Page 4 of 4 Cash Register Receipt City of Tukwila Receipt Number R12546 DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $493.40 D17-0250. Address: 16415 SOUTHCENTER PKWY . App: 9379200290 ' $493.40''. Credit Card Fee $14.37 Credit Card Fee R000.369.908.00.00 0.00 $14.37 DEVELOPMENT $456.43: PERMIT FEE R000.322.100.00.00 0.00 $451.93 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $22.60'. TECHNOLOGY FEE R000.322.900.04.00 0.00 $22.60 TOTAL FEES PAID BY RECEIPT: R12546 $493.40 Date Paid: Wednesday, October 11, 2017 Paid By: TONY D JACKSON Pay Method: CREDIT CARD 033787 Printed: Wednesday, October 11, 2017 2:18 PM 1 of 1 ifeWSYSTEMS DESCRIPTIONS .PermitTRAK ACCOUNT QUANTITY PAID $302.56 .;. D17-0250 Address: 16415 SOUTHCENTER PKWY Apn: 5379200290 $302;96,.; Credit- Card Fee Credit Card Fee PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R12325 R000.369.908.00.00 R000.345.830.00.00 0.00 0.00 $8.81 $293.75 $302.56 Date Paid: Friday, September 15, 2017 Paid By: TONY JACKSON Pay Method: CREDIT CARD 016987 Printed: Friday, September 15, 2017 8:38 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD 50 1\V Retain a copy with permit �f7-�� INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 Project: ��- r(pr•VE / 4) Type of Inspection: Bo/LP/AG Fan -4_ Address: /4,y/5 awn-ear/ER %wY Date Called: Special Instructions: Date Wanted:a.m: /1-717 Requester: Phone No: y23- 970 --/2O7 Approved per applicable codes. O Corrections required prior to approval. COMMENTS: 2}K - BO/ L -D) N - fThf Inspector: Date: ll -717 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 M7-1)296 Project: Ar .t 7— Type of Inspection: /901-P /G /2 Nmi--- Address: /1905 Savrikkivi '/ Date Called: Special Instructions: m// Date Wanted: //`6 /7 a.m. p.m. Requester: Phone No: 52/C yZ5---?'-t267 ElApproved per applicable codes. OCorrections required prior to approval. COMMENTS: / I. k /A/S" e' 'c.77CY Inspector: Date: `/-4 ` / REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 2 3 4 P:\D REVI`~.`ONS No chances shl h m;,d, to the scope of work withot.t prior approval of Tukwila Bui;;ging Division. ' r" flTE: Revisions will require a new Wan submittal c i 7.clrlr+onal plan review fees. 5 Ski-r P ATE ,�E;-,�. FT ,-�s•`t"-� 1 � �:: -1:"hl SfFA fes:', f�,�•. l Mechanical el Electrical Plumbing Gas Piping City of Tukwila 7 8 REVISION HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 09/06/2017 FUNCTION: PROVIDE SHELTER NOTES: ORIGINAL DESIGN CONCEPTS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAWS AND ARE THE PROPERTY OF RAINIER INDUSTRIES, LTD. ANY REPRODUCTION OF THIS DESIGN CONCEPT WITHOUT WRITTEN CONSENT IS EXPRESSLY FORBIDDEN. DELIVERABLES DESCRIPTION QTY NEW AWNING (5 FRAMES) 1 Plot Plan O East and South Side Awning Scale: 1/16" = 1'-0" S\DEVELOPMENT\Sher Partners\392029 - One Wedge Awning\392029-1-1 - one wedge corner awning\Drawing\plot plan.dwg, 9/8/2017 2:22:15 PM, DWG To PDF.pc3 FILE COPY Permit No. pli-O'tD I review approval is subject to errors and omissions, :rarer of construction documents does not authorize Motion of any adopted code or ordnance. Receipt proved Field Copy and conditions admowledget BY: /— Date: WM/ /7 City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2017 1FP- C�1 of Tukwila a BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 1 5 2017 PERMIT CENTER 11- OW SHEET INDEX PAGE SHEET DESCRIPTION DEPARTMENT P1 PLOT PLAN P2 ELEVATION VIEW NEW AWNING P3 ATTACHMENT VIEW NEW AWNING IM EAST AND SOUTH SIDE WEDGE AWNING .X=±1/4" XX = ± 1/16" ANGLES = ± 1° SHER PARTNERS PLOT PIAN RAINfER EPP N/A RAINIER INDUSTRIES LTD. 392029-1-1 P1 P:\D REVISION HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 07/07/2017 ELEVATION VIEW - FRONT EAST AND SOUTH SIDE WEDGE AWNING Scale: 1/4" =1'-0" S\DEVELOPMENT\Sher Partners\392029 - One Wedge Awning\392029-1-1 - one wedge corner awning\Drawing\plot plan.dwg, 9/8/2017 2:22:18 PM, DWG To PDF.pc3 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA SEP 152017 PERMIT CENTER EAST AND SOUTH SIDE WEDGE AWNING .X=±114" .XX =±1116" ANGLES = ± 1° SHER PARTNERS ELEVATION VIEW NEW AWNING RAINIER INDUSTRIES LTD N/A 392029-1.1 P2 2 3 B -•••— 5" TOP 4 I 5 6 7 REVISION HISTORY DESCRIPTION 8 A PRELIMINARY DWG TCS 07/07/2017 EXISTING WALL (BY OTHERS) CAULK-GEOCEL 2300 AWNING TOP BAR FABRIC I- N C 7/ 3/16" THICK x 1" WIDE Z -BRACKET (1 EVERY 37 O.C. - TOP BAR) #14 HEX HD. TEK SCREW 5/16"x3" LAG BOLTS OR RATED ANCHOR 2'-0" PROJECTION 2015 IBC 3105.4 Awnings and canopy materials. Awnings and canopies shall be provided with an approved covering that meets the fire propagation performance criteria of, Test Method 1 or Test Method 2, .as appropriate, of NFPA 701 or has al flame spread index not greater than 25 when tested in accordance with ASTM E 84 or UL 723. Wall Lag Bolt Upper Attachment Scale. istin Wall 5/16"x3" LAG BOLTS OR RATED ANCHOR 3/16" THICK x 1" WIDE Z -BRACKET (1 EVERY 64" O.C. - BOTTOM BAR) #14 HEX HD. TEK SCREW • ELEVATION VIEW - SIDE A EAST AND SOUTH SIDE WEDGE AWNING TYP FOR ALL FRAMES Scale: 1/2" =1'-0" P:\D S\DEVELOPMENT\Sher Partners\392029 - One Wedge Awning\392029-1-1 - one wedge corner awning\Drawing\plot plan.dwg, 9/8/2017 2:22:24 PM, DWG To PDF.pc3 RECEIVED CITY OF TUKWILA AWNING BOTTOM BACK BAR SEP 1 5 2017 Wall Lag Bolt Lower Attachment Scale: 6" = 1'-0" RIEWED FOR OD COMPLIANCE OPPROVED OCT 0 6 2017 City of Tukwila BUILDING DIVISION oFf"ES(ARM EAST AND SOUTH SIDE WEDGE AWNING .X = ± 1/4" 61iER PARTNERS .XX = ± 1/16" ANGLES = ± 1° ATTACHMENT METHOD RAINIER INDUSTRIES LTD WA CRAWING 392029-1-1 P3 GENERAL NOTES 1. These drawings have been prepared primarily to safeguard against major structural damage and loss of life, not to limit damage or maintain function -as per requirements of the current accepted building code as listed in the Basis for Design. 2. An experienced licensed contractor with a working knowledge of applicable codes and industry accepted standard practices shall perform the work depicted in these drawings. 3. All work shall conform to the minimum standards of the current governing building code and industry specific specifications and standards. The contractor shall comply with requirements of all regulatory agencies with authority over any portion of the work. Work not explicitly shown on these drawings shall conform to all applicable codes and accepted standard practices. 4. The contractor shall verify all dimensions, elevations and conditions on these drawings with the architectural and all other discipline drawings prior to start of construction. Notify architect or EOR in writing before the start of construction regarding discrepancies, omissions or variations, or they shall become the sole responsibility of the contractor. Notes and the specific details on these drawings take precedence over general structural notes and typical details. 5. Construction methods are not indicated on these drawings. The contractor shall be solely responsible for all methods, sequences and procedures of construction. The contractor shall provide adequate shoring, bracing, formwork, etc. as required for the protection of life and property during construction. 6. Openings, pockets, etc. larger than 6 inches shall not be placed in structural members unless specifically detailed on these drawings. When drawings by others show items in structural members not shown on the structural drawings, notify the engineer in writing to determine correct disposition. 7. Site visits by the EOR are a resource for the contractor and shall not be considered as special inspections. 8. General inspection and special inspection shall be performed during construction as required by the local goveming municipality. BASIS FOR DESIGN 1. Governing Building Code: 2015 International Building Code 2. Risk Category: II 3. Roof Loads: Dead Load = self weight + 0.25 psf misc. dead load Live Load = 5 psf (non-reducible) Snow Load = 25 psf (minimum required snow load) 4. Wind Design: Basic Wind Speed = 110 mph Wind Exposure = C Mean Roof Height = less than 15'-0" 5. Seismic Design: Wind loads govern lateral structural design. FILE NAME: P:\DTS\DEVELOPMENT\SHER PARTNERS1392029 - ONE WEDGE AWNING \392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ 10.03.2017 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/28/2017 APR STRUCTURAL ALUMINUM 1. All aluminum alloys shall be minimum 6061-T6 with minimum tensile yield stress 35 ksi, U.N.O. 2. All aluminum welds shall conform to current aluminum specifications. 3. Aluminum parts shall be welded with an inert gas shielded arc or resistance welding process. No welding process that requires a welding flux shall be used. Only filler alloys complying with the governing code and specifications requirements shall be used. 4. All welds of structural members shall be performed by welders qualified in accordance with the governing code procedures. 5. Welding of aluminum shall be in accordance with nationally recognized standards. 6. Oxygen cutting of aluminum alloys shall not be permitted. 7. Where aluminum alloy parts are in contact with dissimilar metals (other than stainless, aluminized or galvanized steel) or absorbent building materials likely to be continuously or intermittently wet, the faying surfaces shall be painted or otherwise separated in accordance with the current aluminum specifications. 8. During erection, structural aluminum shall be adequately braced and fastened to resist dead, wind and erection loads. FASTENERS 1. Screws shall be self -tapping hex head sheet metal screws with current ICBO/ICC rating for material into which installation occurs. 2. Screws which are removed shall be replaced with a larger diameter screw where replacement is made into an existing hole. Replace all screws which strip out material. 3. Screws shall be spaced no closer than 5/8" o.c. and maintain a minimum free edge distance of 1/2", U.N.O. 4. Clip angles or flat clips used for attachment shall be a minimum of 33 mils, U.N.O. Size all clip angles and flat clips to maintain minimum screw spacing and edge distances as noted above. 5. All screws #8 and larger shall have a minimum head size of 5/16". All screws shall have sufficient length to ensure penetration into aluminum/steel by at least (2) full diameter threads. 6. All screws shall be a minimum of #8 self -tapping screws, U.N.O. 7. All anchors installed into concrete shall be Hilti KB TZ expansion anchors (ESR -1917) or Hilti HIT -RE 500 -SD adhesive anchors (ESR -2322). All anchors installed into CMU shall be Hilti KB III expansion anchors (ESR - 1385) or Hilti HIT-HY 70 adhesive anchors (ESR -2682). Approved equivalent anchors with curr reports may be used at the contractor's discretion. 8. All bolts shall be installed as bearing -type connections with threads excluded from shear plan connection), U.N.O. High-strength bolts shall be snug tightened using any AISC approved meth require special inspections unless noted otherwise. All bolts in slotted or oversize holes and all bolts shall be installed with washers. SPECIAL INSPECTION 1. All required special inspections shall be performed in accordance with the current accepted b Check with the local building department for required special inspections. 2. The special inspector shall be a qualified person who shall demonstrate competence, to the s local building department, for the inspection of the particular type of construction or operation re inspection. ,t IC►EWED FOR CD'E COMPLIANCE d and d*PPROVED gh-strength OCT 0 6 2017 ilding code. CIt c ai of Tukwila G DIVISION 3. The special inspector shall inspect the work assigned for conformance with the approved contract drawings and specifications. The special inspector shall fumish inspection reports to the local building department, pei EOR and other designated persons required by the governing building official. All discrepancies shall be (+l brought to the immediate attention of the contractor for correction, and then if uncorrected in a reasonable period of time, the EOR and the building official shall be notified. The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspectors knowledg constructed in conformance with the approved plans and specifications and the applicable building code provisions 4. Inspectors shall inspect from an approved set of contract drawings, shop drawings shall not be used in lieu RECEIVED TY OF TUKWILA the approved contract drawings for inspection purposes. 5. Certificate of approval regarding materials and inspection of prefabricated items shall be provided in accordance with the current accepted building code. CORRE TION LTR#� e, OCT 04 2017 IMIT CENTER .XX = ± 1/16" ANGLES = ± 1° EAST AND SOUTH SIDE WEDGE AWNING SHER PARTNERS RAINIER INDUSTRIES LTD ENGINEERING NOTES vg N/A 392029-1-1 AGE PO.5 FRAME 1 FRAMEBREAK 3 FRAMEBREAK 4 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR FUNCTION: TO PROVIDE COVER NOTES: ORIGINAL DESIGN CONCEPTS ARE PROTECTED UNDER FEDERAL COPYRIGHT LAWS AND ARE THE PROPERTY OF RAINIER INDUSTRIES, LTD. ANY REPRODUCTION OF THIS DESIGN CONCEPT WITHOUT WRITTEN CONSENT IS EXPRESSLY FORBIDDEN. FRAMEBREAK 1 FRAMEBREAK 2 FRAME4 10.03.2017 PAGE SHEET DESCRIPTION P0.5 ENGINEERING NOTES DEPARTMENT SCOPE OF WORK PLOT PLAN FRAME2 FRAME 3 RECEIVED CITY OF TUKWILA OCT 04 2011 ISOMETRIC VIEW OF EAST AND SOUTH SIDE WEDGE AWNING QTY (1) DELIVERABLES DESCRIPTION QTY WEDGE AWNING 94' WIDE, 36" TALL, 24" PROJECTION (5 FRAMES) 1 ILE NAME: P:\DTS\DEVELOPMENT\SHER PARTNERS\392029 - ONE WEDGE AWNING\392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO1 PERMIT CENTER P3 ELEVATION VIEW P4 ISOMETRIC CUT LIST FRAME 1 P5 P6 WEDGE DETAIL FRAME 1 M ISOMETRIC CUT LIST FRAME 2 P7 WEDGE DETAIL FRAME 2 P8 ISOMETRIC CUTLIST FRAME 3 P9 WEDGE DETAIL FRAME 3 P10 ISOMETRIC CUT LIST FRAME 4 .X = ± 1/4" .XX =±1/16" ANGLES = ± 1° WEDGE DETAIL FRAME 4 P12 ISOMETRIC CUT LIST FRAME 5 P13 WEDGE DETAIL FRAME 5 AN 1n.oEscnunon EAST D SOUTH SIDE WEDGE AWNING SHER PARTNERS RAINIER INDUSTRIES LTD M M M M M M M SCOPE OF WORK Pta N/A 392029-1-1 P1 1 2 3 4 5 6 7 8 PAD' REVISION HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 09/06/2017 Plot Plan A East and South Side Awning Scale: 1/16" =1'-0" S\DEVELOPMENT\Sher Partners\392029 - One Wedge Awning\392029-1-1 - one wedge corner awning\Drawing\plot plan.dwg, 9/7/2017 9:02:49 AM, Adobe PDF REVIEWED FOR CODE COMPLIANCE APPROVED OCT 062017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 04 2017 PERMIT CENTER 10.03.2017 EAST AND SOUTH SIDE WEDGE AWNING .X = ± 1/4" SHTR PARTNERS .XX =±1/16" ANGLES = ± 1° PLOT PLAN 411110 RAINIER INDUSTRIES LTD N/A 392029-1-1 P2 1 2 3 4 5 6 7 8 660" EAST VIEW OF EAST AND SOUTH SIDE AWNING ASSEMBLY SOUTH VIEW OF EAST AND SOUTH SIDE AWNING ASSEMBLY TYP 1/8V 10.03.2017 24" projectio TYP n SECTION A -A REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR 0.25-14 x lin Tek Screw RAFTER 11 EXISTING WOOD STUD (BY OTHERS) II P!'4g 1 FOR 'y F LIANCE " - ROVED 3-8x3 Lag Bolt Or Rated Anchor Single Hole Z bracket AWNING BACK BAR 0.25-14 x 1 in Tek Screw Single Hole Z bracket OCT 06• 7 REAR B UPPER A IACHMENT DETAIL E IVERY3eity of Tukwila BUILDING DIVISION �1%O0DN'STUD (BY OTHERS) R 3-8x3 Lag Bolt . Or Rated Anchor ECEIVED OF TUKWILA OCT 04 2017 PERMIT CENTER LOWER ATTACHMENT DETAIL F EVERY 64" EAST AND SOUTH SIDE WEDGE AWNING .X =± 1/4' .XX = ± 1/16" ANGLES = ± 1° SHER PARTNERS ELEVATION VIEW aaccx RAINIER INDUSTRIES LTD N/A 392029-1-1 P3 FILE NAME: P:\DTS\DEVELOPMENT\ SHER PARTNERS\392029 - ONE WEDGE AWNING \392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ — 401" I E _� A� I Z ao SOUTH VIEW OF EAST AND SOUTH SIDE AWNING ASSEMBLY TYP 1/8V 10.03.2017 24" projectio TYP n SECTION A -A REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR 0.25-14 x lin Tek Screw RAFTER 11 EXISTING WOOD STUD (BY OTHERS) II P!'4g 1 FOR 'y F LIANCE " - ROVED 3-8x3 Lag Bolt Or Rated Anchor Single Hole Z bracket AWNING BACK BAR 0.25-14 x 1 in Tek Screw Single Hole Z bracket OCT 06• 7 REAR B UPPER A IACHMENT DETAIL E IVERY3eity of Tukwila BUILDING DIVISION �1%O0DN'STUD (BY OTHERS) R 3-8x3 Lag Bolt . Or Rated Anchor ECEIVED OF TUKWILA OCT 04 2017 PERMIT CENTER LOWER ATTACHMENT DETAIL F EVERY 64" EAST AND SOUTH SIDE WEDGE AWNING .X =± 1/4' .XX = ± 1/16" ANGLES = ± 1° SHER PARTNERS ELEVATION VIEW aaccx RAINIER INDUSTRIES LTD N/A 392029-1-1 P3 FILE NAME: P:\DTS\DEVELOPMENT\ SHER PARTNERS\392029 - ONE WEDGE AWNING \392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ 1 2 3 4 5 6 7 8 QTY. DESCRIPTION Part 1 1 lin x lin x 0.125in Staple Tube 1210-0006 Direction Up LENGTH ANGLE1 ANGLE2 3913/16" 14.25 61.50 2 1 lin x lin x 0.110in Alum. Tube 1210-0011 35" 0.00 45.00 3 1 lin x lin x 0.125in Staple Tube 1210-0006 Up 5" 0.00 0.00 4 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 1" 0.00 0.00 5 1 lin x lin x 0.110in Alum. Tube 1210-0011 196" 0.00 0.00 6 1 lin x lin x 0.110in Alum. Tube 1210-0011 197" 0.00 0.00 7 7 lin x lin x 0.110in Alum. Tube 1210-0011 3913/16" 61.58 28.42 8 3 lin x lin x 0.110in Alum. Tube 1210-0011 22 3/8" 0.00 0.00 9 3 lin x lin x 0.110in Alum. Tube 1210-0011 34" 0.00 0.00 10 1 lin x lin x 0.110in Alum. Tube 1210-0011 23" 45.00 0.00 11 lin x lin x 0.125in Staple Tube 1210-0006 Down 196" 0.00 0.00 12 1 lin x lin x 0.125in Staple Tube 1210-0006 Out • 5" 45.00 0.00 13 1 lin x lin x 0.125in Staple Tube 1210-0006 Forward 39 13/16" 14.25 0.00 14 1 lin x lin x 0.125in Staple Tube 1210-0006 Forward 1" 45.00 14.25 15 1 lin x lin x 0.125in Staple Tube 1210-0006 Down 24" 45.00 45.00 16 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 36" 0.00 45.00 17 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 198" 45.00 0.00 18 7 lin x lin x 0.110in Alum. Tube 1210-0011 3" 0.00 0.00 REVISIONS HISTORY REV DESCRIPTION A PRELIMINARY DWG BY TCS DATE 9/06/2017 APPR APR ISOMETRIC VIEW OF SOUTH SIDE FRAME 1 RECEIVED CITY OF TUKWILA OCT 0 4 2011 PERMIT CENTER 10.03.2017 PAW OESCRIPPOA EAST AND SOUTH SIDE WEDGE AWNING = ± 1/4" .XX =±1/16" ANGLES = ± 1° SHER PARTNERS ISOMETRIC CUT LIST FRAME 1 RAINIER INDUSTRIES LTD RAINIER PAW" A 392029-1-1 PAGE P4 FILE NAME: P:\DTS\DEVELOPMENT\ SHER PARTNERS1392029 - ONE WEDGE AWNING1392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ 2 3 4 5 6 7 8 O CN 00 O, Cl) 00 N N O' TOP VIEW OF FRAME 1 198" FRONT VIEW OF FRAME 1 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR RECEIVED CITY OF TUKWILA OCT 042017 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2017 City of Tukwila 1NG DIVISION CO 24" RIGHT VIEW OF FRAME 1 10.03.2017 EAST AND SOUTH SIDE WEDGE AWNING .X=± 1/4' .XX =±1/16" ANGLES = ± 1° SHER PARTNERS WEDGE FRAME 1 RAINIER INDUSTRIES LTD N/A Pte. 39202971.1 PAG P5 FILE NAME: P:\DTS\DEVELOPMENT\SHER PARTNERS\392029 - ONE WEDGE AWNING\392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ 1 2 3 4 5 6 7 8 QTY. DESCRIPTION Part 1 1 lin x lin x 0.125in Staple Tube 1210-0006 2 1 lin x lin x 0.125in Staple Tube 1210-0006 Direction Up Out LENGTH ANGLE1 ANGLE2 5" 0.00 0.00 3913/16" 14.25 61.50 3 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 1" 0.00 0.00 4 1 1M x 1M x 0.110in Alum. Tube 1210-0011 220" 0.00 0.00 5 1 lin x lin x 0.110in Alum. Tube 1210-0011 203" 45.00 0.00 6 8 lin x lin x 0.110in Alum. Tube 1210-0011 3913/16" 61.58 28.42 7 4 lin x lin x 0.110in Alum. Tube 1210-0011 22 3/8" 0.00 0.00 8 4 lin x lin x 0.110in Alum. Tube 1210-0011 34" 0.00 0.00 9 1 lin x 1in x 0.110in Alum. Tube 1210-0011 23" 0.00 45.00 10 1 lin x lin x 0.125in Staple Tube 1210-0006 Down 221" 45.00 0.00 11 1 1in x lin x 0.110in Alum. Tube 1210-0011 4" 45.00 0.00 12 1 lin x lin x 0.110in Alum. Tube 1210-0011 36" 45.00 0.00 13 1 lin x lin x 0.125in Staple Tube 1210-0006 Down 24" 45,00 0.00 14 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 3913/16" 0.00 30.75 15 1 lin x lin x 0.110in Alum. Tube 1210-0011 44 3/8" 37.51 16 8 lin x lin x 0.110in Alum. Tube 1210-0011 3" 0.00 0.00 17 lin x lin x 0.125in Staple Tube 1210-0006 Back 173 5/16" 0.00 0.00 18 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 5 1/16" 30.75 0.00 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR ISOMETRIC VIEW OF SOUTH SIDE FRAME 2 RECEIVED CITY OF TUKWILA OCT 042011 PERMIT CENTER 1.0.03.2017 EAST AND SOUTH SIDE WEDGE AWNING .XX =±1/16" ANGLES = ± 1° SHER PARTNERS ISOMETRIC CUT LIST FRAME 2 RAINIER INDUSTRIES LTD F.'s N/A 392029-1.1 PAGE P6 FILE NAME: P:\DTS\DEVELOPMENT\SHER PARTNERS \392029- ONE WEDGE AWNING\392029-1-1 - ONE WEDGE CORNER AWNING \ DRAWING \PACK AND GO\ 6 7 8 O co —100 co N CON' MI00 I� N N. N N N TOP VIEW OF FRAME 2 222" N FRONT VIEW OF FRAME 2 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2017 City of Tukwila DIVISIONBUILDING RECEIVED CITY OF TUKWILA OCT 04 2017 PERMIT CENTER 24" RIGHT VIEW OF FRAME 2 10.03.2017 EAST AND SOUTH SIDE WEDGE AWNING .X = ± 1/4" .XX = ± 1/16" ANGLES = ± 1° SHER PARTNERS WEDGE DETAIL FRAME 2 RAINIER RAINIER INDUSTRIES LTD N/A 392029-1-1 P7 FILE NAME: P:\DTS\DEVELOPMENT\ SHER PARTNERS \392029 - ONE WEDGE AWNING\392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ A 1 2 3 4 5 6 7 8 QTY. DESCRIPTION Part Direction LENGTH ANGLE1 ANGLE2 1 1 lin x lin x 0.125in Staple Tube 1210-0006 Down 218" 0.00 0.00 2 3 lin x lin x 0.110in Alum. Tube 1210-0011 34" 0.00 0.00 3 3 lin x lin x 0.110in Alum. Tube 1210-0011 22 3/8" 0.00 0.00 4 2 lin x lin x 0.125in Staple Tube 1210-0006 Forward 1 0.00 0.00 5 1 3/4in x 3/4in x 0.110in Alum. Tube 1210-0010 220" 0.00 0.00 6 lin x f in x 0.110in Alum. Tube 1210-0011 218" 0.00 0.00 7 7 lin x lin x 0.110in Alum. Tube 1210-0011 3911/16" 61.50 28.50 8 1 lin x lin x 0.110in Alum. Tube 1210-0011 220" 0.00 0.00 9 7 lin x lin x 0.110in Alum. Tube 1210-0011 3" 0.00 0.00 10 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 220" 0.00 0.00 11 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 3913/16" 14.25 61.50 12 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 39 13/16" 14.25 61.50 13 2 lin x lin x 0.110in Alum. Tube 1210-0011 36" 45.00 0.00 14. 2 lin x lin x 0.110in Alum. Tube 1210-0011 23" 0.00 45.00 15 2 lin x lin x 0.125in Staple Tube 1210-0006 Out 5" 0.00 0.00 C - D E REVISIONS HISTORY REV A DESCRIPTION PRELIMINARY DWG BY DATE TCS 9/06/2017 APPR APR ISOMETRIC VIEW OF EAST SIDE FRAMES 3 RECEIVED CITY OF TUKWILA OCT 042011 PERMIT CENTER 1.0.03.2017 EAST AND SOUTH SIDE WEDGE AWNING .X=±1/4" .XX =±1/16" ANGLES =± 1° SHER PARTNERS ISOMETRIC CUT LIST FRAME 3 RAINIER INDUSTRIES LTD RAINIER N/A P,A 392029-1.1 P8 FILE NAME: P:\DTS\DEVELOPMENT\SHER PARTNERS \392029- ONE WEDGE AWNING\392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ 8 O c,ICO cr)1-:i' —ICO ^�N FICO O• •O I� CV O c') N • LO CO • Lola) O N N N TOP VIEW OF FRAME 4 220" FRONT VIEW OF FRAME 4 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR 24" RIGHT VIEW OF FRAME 4 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 042017 PERMIT CENTER 10.03.2017 EAST AND SOUTH SIDE WEDGE AWNING .X = ± 1/4" SHER PARTNERS .XX =±1/16" ANGLES = ±'1° WEDGE DETAIL FRAME 3 A�\ p RAINIER INDUSTRIES LTD N/A 392029-1-1 PAGE P9 FILE NAME: P:\DTS\DEVELOPMENT\ SHER PARTNERS\392029 - ONE WEDGE AWNING\392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING \PACK AND GO\ 1 2 3 4 5 6 7 8 QTY. DESCRIPTION Part Direction LENGTH ANGLE1 ANGLE2 1 1 lin x lin x 0.125in Staple Tube 1210-0006 Down 218" 0.00 0.00 2 3 lin x lin x 0.110in Alum. Tube 1210-0011 34" 0.00 0.00 3 3 lin x lin x 0.110in Alum. Tube 1210-0011 22 3/8" 0.00 0.00 4 2 lin x lin x 0.125in Staple Tube 1210-0006 Forward 1' 0.00 0.00 5 1 3/4in x 3/4in x 0.110in Alum. Tube 1210-0010 220" 0.00 0.00 6 1 lin x lin x 0.110in Alum. Tube 1210-0011 218" 0.00 0.00 7 7 1 in x 1 in x 0.110in Alum. Tube 1210-0011 3911/16" 61.50 28.50 8 1 lin x lin x 0.110in Alum. Tube 1210-0011 220" 0.00 0.00 9 7 lin x lin x 0.110in Alum. Tube 1210-0011 3" 0.00 0.00 10 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 39 13/16" 14.25 61.50 11 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 39 13/16" 14.25 61.50 12 2 lin x lin x 0.110in Alum. Tube 1210-0011 36" 45.00 0.00 13 2 lin x lin x 0.110in Alum. Tube 1210-0011 23" 0.00 45.00 14 2 1 in x 1 in x 0.125in Staple Tube 1210-0006 Out 5" 0.00 0.00 15 lin x lin x 0.125in Staple Tube 1210-0006 Back 137 7/8" 0.00 0.00 16 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 55 3/4" 0.00 0.00 REVISIONS HISTORY REV DESCRIPTION A PRELIMINARY DWG BY TCS DATE 9/06/2017 APPR APR REVIEWED FOR CODE COMPLIANCE APPROVED ISOMETRIC VIEW OF EAST SIDE FRAME 4 10.03.2017 .X=± 1/4" .XX =±1/16" ANGLES = ± 1° RECEIVED CITY OF TUKWILA OCT 042011 PERMIT CENTER EAST AND SOUTH SIDE WEDGE AWNING SHER PARTNERS ISOMETRIC CUT LIST FRAME 4 RAINIER INDUSTRIES LTD RAINIER PAW 392029-1-1 PAU P 1 0 FILE NAME: P:\DTS\DEVELOPMENT\SHER PARTNERS\392029 - ONE WEDGE AWNING \392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ 1 2 3 4 5 6 7 8 O CV CO ^�CV 1�ICO -1-s O, �O O CO ,O O (N CV CV TOP VIEW OF FRAME 4 220" FRONT VIEW OF FRAME 4 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR 24" RIGHT VIEW OF FRAME 4 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 042011 PERMIT CENTER 10.03.2017 EAST AND SOUTH SIDE WEDGE AWNING .X=±1/4" .XX = ± 1/16" ANGLES =± 1° SHER PARTNERS WEDGEpDETAIL FRAME 4 AAIh91@i7 RAINIER INDUSTRIES LTD NIEN N/A P� 392029-1-1 PAGE P11 FILE NAME: P:\DTS\DEVELOPMENT\SHER PARTNERS \ 392029 - ONE WEDGE AWNING\392029-1-1 - ONE WEDGE CORNER AWNINGIDRAWING\PACK AND GO\ A 4 5 6 7 8 QTY. DESCRIPTION Part Direction LENGTH ANGLE1 ANGLE2 1 1 1 in x 1 in x 0.125in Staple Tube 1210-0006 Down 220" 0.00 0.00 2 3 lin x lin x 0.110in Alum. Tube 1210-0011 34" 0.00 0.00 3 3 lin x lin x 0.110in Alum. Tube 1210-0011 22 3/8" 0.00 0.00 4 1 lin x lin x 0.125in Staple Tube 1210-0006 Forward 1" 45.00 0.00 5 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 24" 45.00 45.00 6 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 36" 0.00 45.00 7 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 192 5/8" 0.00 0.00 8 1 lin x lin x 0.110in Alum. Tube 1210-0011 218" 0.00 0.00 9 7 lin x lin x 0.110in Alum. Tube 1210-0011 3911/16" 61.50 28.50 10 1 lin x lin x 0.125in Staple Tube 1210-0006 Back 36" 0.00 45.00 B 11 1 lin x lin x 0.125in Staple Tube 1210-0006 Forward 1" 45.00 14.25 12 7 lin x lin x 0.110in Alum. Tube 1210-0011 3" 0.00 0.00 13 2 lin x lin x 0.125in Staple Tube 1210-0006 Up 5" 0.00 0.00 14 1 lin x lin x 0.125in Staple Tube 1210-0006 Down 24" 45.00 45.00 15 1 lin x lin x 0.125in Staple Tube 1210-0006 Forward 3913/16" 14.25 61.50 16 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 3913/16" 14.25 61.50 17 1 lin x lin x 0.125in Staple Tube 1210-0006 Out 1" 45.00 0.00 18 1 3/4in x 3/4in x 0.110in Alum. Tube 1210-0010 220" 0.00 0.00 19 1 lin x lin x 0.110in Alum. Tube 1210-0011 220" 0.00 0.00 C REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2017 City of Tukwila UILDING DIVISION RECEIVED CITY OF TUKWILA OCT 0 4 2017 ISOMETRIC VIEW OF EAST SIDE FRAME 5 10.03.2017 .X=±1/4" .XX =±1/16" ANGLES = ± 1° PER T"" CENTER EAST AND SOUTH SIDE WEDGE AWNING SHER PARTNERS ISOMETRIC CUT LIST FRAME 5 RAINIER INDUSTRIES LTD N/A 392029-1.1 PAGE P12 FILE NAME: P:\DTS\DEVELOPMENT\SHER PARTNERS\392029 - ONE WEDGE AWNING Q92029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ p O LO Ioo 0, O N N TOP VIEW OF FRAME 5 FRONT VIEW OF FRAME 5 REVISIONS HISTORY REV DESCRIPTION BY DATE APPR A PRELIMINARY DWG TCS 9/06/2017 APR RIGHT VIEW OF FRAME 5 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 042017 PERMIT CENTER 10.03.2017 EAST AND SOUTH SIDE WEDGE AWNING .X=±1/4" .XX=±1/16" ANGLES = ± 1° SHER PARTNERS WEDGE DETAIL FRAME 5 RAINIER INDUSTRIES LTD PAI No". /A 392029-1-1 PAGE P13 FILE NAME: P:\DTS\DEVELOPMENT\ SHER PARTNERS\392029 - ONE WEDGE AWNING\392029-1-1 - ONE WEDGE CORNER AWNING\DRAWING\PACK AND GO\ 1hhDrNEINEERINE STRUCTURAL ENGINEERS & CONSULTANTS r"Ni STRUCTURAL CALCULATIONS PROJECT NAME: Awnings at Sher Partners PROJECT ADDRESS: 16415 Southcenter Parkway, Tukwila, WA 98188 PROJECT NO: 17206 CLIENT: Luke Walker COMPANY: Rainer Industries 18375 Olympic Ave. S Tukwila, WA 98188 DATE: Oct 03, 2017 10/03/2017 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 6 2011 City of Tukwila BUILDING DIVISION HW Engineering License and Non Disclosure and Reproduction IMPORTANT NOTICE TO BUILDING AND SAFETY PERSONNEL - The enclosed calculations and hard copy prints ("Enclosed") are copyright protected by HW Engineering. It is understood that while the Enclosed may be required for verification of structural design and approval, it is not necessary for the manufacture or construction of the structure or its components. It is the express wish of HW Engineering that these proprietary calculations not be retumed or redistributed to anyone other than the copyrighted owner as referenced in the ownership paragraph below and that any unnecessary submitted copies be retumed or destroyed. Ownership: This document and the Enclosed are copyrighted by HW Engineering, 6270 McLeod Drive, Suite 140, Las Vegas, NV 89120. All rights reserved. This is not a sale or transference; all right, title and interest in the Document (in both electronic file and hard copy) belong to HW Engineering. REV DATE BY DESCRIPTION �n�� G—e CI'8'Y OF T A D A OCT 0I. A A CORRE TION LTR# Ng- ED KKWILA 2011 PERMIT CENTER 6270 McLeod Drive, Suite 140, Las Vegas, NV 89120 Phone: 702.202.0061 hongyu@hwengineeringUSA.com www.hwengineeringUSA.com HW Engingering Job #17206 1/18 10/03/2017 Basis for Design 1.1 BUILDING CODE: 2015 International Building Code 1.2 GRAVITY DESIGN: ROOF LOADING DEAD LOAD (PSF) Frame self -weight LIVE LOAD (PSF) 5psf SNOW LOAD (PSF) 25psf(minimum required) 1.3 LATERAL DESIGN: WIND LOADING Basic Wind Speed (3s — Gust) 110 Risk Category II Exposure Category C SEISMIC LOADING Risk Category II Ss, SI 1.457, 0.543 Soil Site Class D Sds, Shc 0.971, 0.543 Seismic Design Category D ap,R, 1.0, 2.5 2.1 ALUMINUM DESIGN: Extruded 6061-T6 with minimum yield stress equal to 35 ksi. ER4043 electrodes/rods shall be used for all aluminum to aluminum welds. 3.1 INSPECTION, SPECIAL INSPECTION, AND STRUCTURAL OBSERVATION: AS REQUIRED BY THE GOVERNING MUNICIPALITY. HW Engingering Job #17206 2/18 SAP2000 10/03/2017 SAP2000 - File:Awnings at Sher Partners - 3-D View HW Engingering Job #17206. 3/18 - 10/03/2017 Design Summary The analysis and design of the awning system included herein were performed with the use of a 3D frame analysis and computer design program — SAP2000. It is a structural analysis program developed by Computers and Structures, Inc. Detailed information about the software can be found at the Computers and Structures, Inc. website. 1. FRAME GEOMETRY The geometry for the awning model was based on a centerline interpretation of a typical awning. The centerline computer model was developed from client drawings and compiled to create a simplified model for analysis. 2. EXTERNALLY APPLIED LOADS Loads for this structure have been conservatively determined by referencing the current International Building Code 2015(IBC 2015) and ASCE 7-10 Standards and Provisions. Design dead load was based on the awning self -weight plus an additional dead load of 0.25 psf to account for the weight of the cover panel. Live load was taken to be 5 psf per code requirement. Wind load was calculated based on "Components and Cladding" for enclosed buildings (see design load calculation). 3. ANALYSIS FOR MEMBER FORCES The awning frame will be constructed of lxlx.11 and 3/4x3/4x.11 aluminum tubes. Refer to structural drawings for detailed member sizes and locations. From computer structural analysis, all framing members were designed based on the above mentioned design loads. Aluminum Design ASD design specifications were used to check the structural capacities of these members based on an applicable minimum yield stress. The demand/capacity ratio of each framing member was calculated and found to be less than 1.0 for all members. All connections were checked by hand calculation based on worst case structural analysis output reactions. HW Engingering Job #17206 4/18 10/03/2017 Design Loads Design Dead Loads Framing and roof panel self weight. Framing weight will be included in to computer model automatically. Add 0.25 psf for roof panel weight. DL = 0.25psf LL = 5psf (Non_reducible per ASCE 7-10 Table 4-1) Design Live Loads Design Wind Loads Wind parameters: 110 mph wind speed, exposure C. Wind loads are based on IBC2015/ASCE 7-10 components and cladding for enclosed buildings wall zone 4 effective wind area 20sgf (Figures 30.5-1). Mean roof height is less than 15ft. V= 110 mph = 1.0 for slope over 45degree 20.8 Pnet30 = psf -22.6 Figure 26.5-1A basic wind speed for occupancy category II Section 26.8.2 Figure 30.5-1 X = 1.21 Figure 30.5-1, exposure C design windpressure = 25.17 g P = � kzt Pnet30 P \-27.35) Psf Design wind force shall be not less than 16psf according as section 30.2.2 of ASCE 7-10 "min = 16 psf Design Snow Load Ground snow load pg = 15 psf 1 = 1.0 Ce = 0.9 Ct=1.2 Cs=0.4 pf = 0.7 Ce Ct I pg pf = 11.34 psf ps = Cs pf Ps = 4.54 psf snow load (sloped roof snow load) Snow = max(ps,25 psf) Snow = 25 psf Design Seismic Loads larger than live load Design perASCE7-10. Ip = 1.0 SDS = 0.971 ap = 1.0 Rp = 2.5 L = 220 in B = 24 in Framing and roof panel total weight will be no more than 2 psf 0.4 ap SDS DL IP ( z1 Seismic force Fpl = 1 + 2 -z) I Rp h Fp2 = 1.6 SDS Ip DL Fp3 = 0.3 SDS Ip DL Fp = 0.7max(min(Fp1, Fp),Fp3) Total max. seismic load Seismic = F B L Minimum wind load design Windmin = 0.6 (16 psf 0.5B h) DL = 2 psf Fp1 = 0.93 psf Fp2 = 3.107 psf maximum force Fp3 = 0.58 psf minimum force Fp = 0.65 psf Seismic = 24 lbf Windmin = 29 lbf Check = if(W indmin > Seismic, "Wind controls design" , "Seismic controls design" ) Check = "Wind controls design" HW Engingering Job #17206 5/18 Design Maps Summary Report User -Specified Input Report Title Awnings at Sher Partners Tue October 3, 2017 13:20:13 UTC Building Code Reference Document ASCE 7-10 Standard (which utilizes USGS hazard data available in 2008) Site Coordinates 47.45592°N, 122.26284°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III Vashort B trier'« 11� �F{t}J14r., 1: ►1UiL i"EA'TJ' t'u'b! penton SEATTLE+ TACOVA INTL Des Moines 'lent Is aquah Maple Valley ;• USGS-Provided Output SS = 1.457 g Si = 0.543 g SMS = 1.457 g SM1 = 0.815 g +Covington SDS = 0.971 g SD1 = 0.543 g ,Hol Ce 10/03/2017 For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. DACE Response Spectrum 185 1.10 tss 1.00 1.75 aM 127 n 0 1A5 a ti coo o+ asj 1°n 0.75 ai 0-00 n$] na0 CIA5 a 70 0.30 13.20 0.15 0.10 0.013 alb 0.03 1327 131° ass neo 1.10 127 140 1si tm 2130 am OM 040 as0 CUM 1.00 127 1.4.0 1.50 1EJ 2fl1 Design Response Spectrum Perrod T (sec) For PGAM, TL, CRS, and CRl values, please view the detailed report. Period. T (sec) HW Engingering Job #17206 6/18 SA?2000 10/03/2017 SAP2000 - File:Awnings at Sher Partners - 3-D View HW Engingering Job ##17206 7/18 SAP2000 10/03/2017 SAP2000 - File:Awnings at Sher Partners - 3-D View HW Engingering Job #17206 8/18 SAP2000 10/03/2017 SAP2000 - File:Awnings at Sher Partners - 3-D View HW Engingering Job #17206 9/18 SAP2000 10/03/2017 SAP2000 - File:Awnings at Sher Partners -Aluminum P -M Interaction Ratios (AA -ASD) 1-1W Engingering Job #17206 10/18 10/03/2017 Table: Material Properties 03c - Aluminum Data Material AlumType Alloy Fcy Fty Ftu Fsu SSHysType 1 Kipfin2 Kip/in2 Kip/in2 Kip/in2 6061T6 Wrought 6061-T6 35.000 35.000 38.000 24.000 Kinematic Table: Frame Section Properties 01 - General SectionName Material Shape t3 t2 tf tw in in in in 1X1X.11 6061T6 Box/Tube 1.0000 1.0000 0.1100 0.1100 lSectionName Area TorsConst in2 in4 133 122 AS2 AS3 S33 in4 in4 in2 in2 in3 1X1X.11 6061T6 Box/Tube 1.0000 1.0000 0.1100 0.1100 1X1X.11 SectionName 1X1X.11 S22 Z33 Z22 R33 R22 ConcCol ConcBeam in3 in3 in3 in in I! 0.10 0.13 0.13 0.3661 0.3661 No No SectionName Color TotalWt TotalMass FromFile AMod A2Mod A3Mod Kip Kip-s2Tn 1X1X.11 8421631 0.073 1.904E-04 No 1.000000 1.000000 1.000000 SectionName JMod I2Mod I3Mod MMod WMod GUID 1X1X.11 1.000000 1.000000 1.000000 1.000000 1.000000 Table: Load Pattern Definitions LoadPat DesignType SelfWtMult AutoLoad GUID Notes Dead DEAD 1.000000 SN SNOW 0.000000 W16 WIND 0.000000 None WA . WIND 0.000000 None WB WIND 0.000000 None Table: Load Case Definitions Case Type InitialCond ModalCase BaseCase DesTypeOpt DesignType DesActOpt DL SN LinStatic LinStatic HW Engingering Job #17206 Zero Zero Prog Det DEAD Prog Det Prog Det SNOW Prog Det 10/03/2017 Case Type InitialCond ModalCase BaseCase DesTypeOpt DesignType DesActOpt W16 LinStatic Zero Prog Det WIND Prog Det WA LinStatic Zero Prog Det WIND Prog Det WB LinStatic Zero Prog Det WIND Prog Det Case DesignAct AutoType RunCase CaseStatus GUID Notes 1 DL Non -Composite None Yes Finished SN Short -Term Composite None Yes Finished W16 Short -Term Composite None Yes Finished WA Short -Term Composite None Yes Finished WB Short -Term Composite None Yes Finished Table: Combination Definitions ComboName ComboType , AutoDesign CaseType CaseName ScaleFactor SteelDesign DL+SN Linear Add No Linear Static DL 1.000000 Strength DL+SN Linear Static SN 1.000000 DL+0.6WA Linear Add No Linear Static DL 1.000000 Strength DL+0.6WA Linear Static WA 0.600000 DL+0.6WB Linear Add No Linear Static DL 1.000000 Strength DL+0.6WB Linear Static WB 0.600000 DL+0.6W16 Linear Add No Linear Static DL 1.000000 Strength DL+0.6W16 Linear Static W16 0.600000 0.6DL+0.6WA Linear Add No Linear Static DL 0.600000 Strength 0.6DL+0.6WA Linear Static WA 0.600000 0.6DL+0.6WB Linear Add No Linear Static DL 0.600000 Strength 0.6DL+0.6WB Linear Static WB 0.600000 DL+0.75(SN+0.6WA) Linear Add No Linear Static DL 1.000000 Strength DL+0.75(SN+0.6WA) Linear Static SN 0.750000 DL+0.75(SN+0.6WA) Linear Static WA 0.450000 DL+0.75(SN+0.6WB) Linear Add No Linear Static DL 1.000000 Strength DL+0.75(SN+0.6WB) Linear Static SN 0.750000 DL+0.75(SN+0.6WB) Linear Static WB 0.450000 DL+0.75(SN+0.6W16) Linear Add No Linear Static DL 1.000000 Strength DL+0.75(SN+0.6W16) Linear Static W16 0.450000 DL+0.75(SN+0.6W16) Linear Static SN 0.750000 Table: Frame Loads Distributed I Frame LoadPat CoordSys Type Dir DistType RelDistA ReIDistB FOverLA FOverLB Lb/ft Lb/ft 5 WB Local Force 2 RelDist 0.0000 1.0000 62.68 62.68 5 WA Local Force 2 RelDist 0.0000 1.0000 -57.68 -57.68 5 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 36.67 36.67 5 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 57.29 57.29 HW Engingering Job #17206 12/18 10/03/2017 Frame LoadPat CoordSys Type Dir DistType RelDistA RelDistB FOverLA FOverLB Lb/ft Lb/ft 5 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 0.57 0.57 1 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 0.29 0.29 1 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 28.65 28.65 1 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 18.33 18.33 1 WA Local Force 2 RelDist 0.0000 1.0000 -28.84 -28.84 1 WB Local Force 2 RelDist 0.0000 1.0000 31.34 31.34 2 WB Local Force 2 RelDist 0.0000 1.0000 62.68 62.68 2 WA Local Force 2 RelDist 0.0000 1.0000 -57.68 -57.68 2 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 36.67 36.67 2 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 57.29 57.29 2 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 0.57 0.57 3 WB Local Force 2 RelDist 0.0000 1.0000 62.68 62.68 3 WA Local Force 2 RelDist 0.0000 1.0000 -57.68 -57.68 3 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 36.67 36.67 3 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 57.29 57.29 3 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 0.57 0.57 4 WB Local Force 2 RelDist 0.0000 1.0000 62.68 62.68 4 WA Local Force 2 RelDist 0.0000 1.0000 -57.68 -57.68 4 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 36.67 36.67 4 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 57.29 57.29 4 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 0.57 0.57 7 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 0.29 0.29 7 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 28.65 28.65 7 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 18.33 18.33 7 WA Local Force 2 RelDist 0.0000 1.0000 -28.84 -28.84 7 WB Local Force 2 RelDist 0.0000 1.0000 31.34 31.34 6 WB . Local Force 2 RelDist 0.0000 1.0000 62.68 62.68 6 WA Local Force 2 RelDist 0.0000 1.0000 -57.68 -57.68 6 W16 GLOBAL Force Y Proj RelDist 0.0000 1.0000 36.67 36.67 6 SN GLOBAL Force Gravity RelDist 0.0000 1.0000 57.29 57.29 6 Dead GLOBAL Force Gravity RelDist 0.0000 1.0000 0.57 0.57 Table: Preferences - Aluminum Design - AA -ASD THDesign FrameType SRatioLimit Maxiter LatFact UseLatFact Bridge Envelopes Moment Frame 1.000000 1 1.230000 No No Table: Aluminum Design 1 - Summary Data - AA -ASD Frame DesignSect DesignType Ratio RatioType Combo 8 1X1X.11 Beam 0.430916 PMM DL+0.75(SN+0.6WA) 5 1X1X.11 Brace 0.337956 PMM DL+0.75(SN+0.6WA) 23 1X1X.11 Beam 0.362127 PMM DL+0.75(SN+0.6WA) 11 1X1X.11 Beam 0.429266 PMM DL+0.75(SN+0.6WA) 1 1X1X.11 Brace 0.245616 PMM DL+0.75(SN+0.6WA) 19 1X1X.11 Beam 0.185863 PMM DL+0.75(SN+0.6WA) HW EngingeringJob #17206 13/18 10/03/2017 Frame DesignSect DesignType Ratio RatioType Combo 9 1X1X.11 Beam 0.369514 PMM DL+0.75(SN+0.6WA) 14 1X1X.11 Column 0.269790 PMM DL+0.75(SN+0.6WA) 26 1X1X.11 Beam 0.010849 PMM DL+0.75(SN+0.6WA) 18 1X1X.11 Beam 0.083641 PMM DL+0.75(SN+0.6WA) 2 1X1X.11 Brace 0.358069 PMM DL+0.75(SN+0.6WA) 20 1X1X.11 Beam 0.195493 PMM DL+SN 3 1X1X.11 Brace 0.337956 PMM DL+0.75(SN+0.6WA) 21 1X1X.11 Beam 0.362127 PMM DL+0.75(SN+0.6WA) 10 1X1X.11 Beam 0.429266 PMM DL+0.75(SN+0.6WA) 4 1X1X.11 Brace 0.375020 PMM DL+0.75(SN+0.6WA) 22 1X1X.11 Beam 0.203972 PMM DL+SN 15 1X1X.11 Column 0.447020 PMM DL+0.75(SN+0.6WA) 16 1X1X.11 Column 0.447020 PMM DL+0.75(SN+0.6WA) 7 1X1X.11 Brace 0.245616 PMM DL+0.75(SN+0.6WA) 25 1X1X.11 Beam 0.185863 PMM DL+0.75(SN+0.6WA) 12 1X1X.11 Beam 0.369514 PMM DL+0.75(SN+0.6WA) 6 1X1X.11 Brace 0.358069 PMM DL+0.75(SN+0.6WA) 24 1X1X.11 Beam 0.195493 PMM DL+SN 17 1X1X.11 Column 0.269790 PMM DL+0.75(SN+0.6WA) 13 1X1X.11 Beam 0.039008 PMM DL+0.6WB Table: Joint Reactions E. Joint OutputCase CaseType F1 F2 F3 Kip Kip Kip 1 DL+SN Combination 0.000 -0.074 0.026 1 DL+0.6WA Combination 0.000 -0.072 0.020 1 DL+0.6WB Combination 0.000 0.072 -0.016 1 DL+0.6W16 Combination 0.000 -0.033 0.010 1 0.6DL+0.6WA Combination 0.000 -0.071 0.019 1 0.6DL+0.6WB Combination 0.000 0.073 -0.018 1 DL+0.75(SN+0.6WA) Combination 0.000 -0.108 0.034 1 DL+0.75(SN+0.6WB) Combination 0.000 0.000 0.006 1 DL+0.75(SN+0.6W16) Combination 0.000 -0.079 0.026 2 DL+SN Combination 0.000 -0.153 0.048 2 DL+0.6WA Combination 0.000 -0.151 0.038 2 DL+0.6WB Combination 0.000 0.154 -0.032 2 DL+0.6W16 Combination 0.000 -0.070 0.018 2 0.6DL+0.6WA Combination 0.000 -0.149 0.036 2 0.6DL+0.6WB Combination 0.000 0.156 -0.034 2 DL+0.75(SN+0.6WA) Combination 0.000 -0.226 0.062 2 DL+0.75(SN+0.6WB) Combination 0.000 0.003 0.010 2 DL+0.75(SN+0.6W16) Combination 0.000 -0.165 0.047 3 DL+SN Combination 0.000 -0.153 0.048 3 DL+0.6WA Combination 0.000 -0.151 0.038 3 DL+0.6WB Combination 0.000 0.154 -0.032 3 DL+0.6W16 Combination 0.000 -0.070 0.018 3 0.6DL+0.6WA Combination 0.000 -0.149 0.036 HW Engingering Job #17206 14/18 Joint OutputCase Casetype Fl F2 F3 Kip Kip Kip 3 0.6DL+0.6WB Combination 0.000 3 DL+0.75(SN+0.6WA) Combination 0.000 3 DL+0.75(SN+0.6WB) Combination 0.000 3 DL+0.75(SN+0.6W16) Combination 0.000 4 DL+SN Combination 0.000 4 DL+0.6WA Combination 0.000 4 DL+0.6WB Combination 0.000 4 DL+0.6W16 Combination 0.000 4 0.6DL+0.6WA Combination 0.000 4 0.6DL+0.6WB Combination 0.000 4 DL+0.75(SN+0.6WA) Combination 0.000 4 DL+0.75(SN+0.6WB) Combination 0.000. 4 DL+0.75(SN+0.6W16) Combination 0.000 5 DL+SN Combination 0.008 5 DL+0.6WA Combination 0.006 5 DL+0.6WB Combination -0.007 5 DL+0.6W16 Combination 0.003 5 0.6DL+0.6WA Combination 0.006 5 0.6DL+0.6WB Combination -0.007 5 DL+0.75(SN+0.6WA) Combination 0.011 5 DL+0.75(SN+0.6WB) Combination 0.001 5 DL+0.75(SN+0.6W16) Combination 0.008 6 DL+SN Combination -0.004 6 DL+0.6WA Combination -0.003 6 DL+0.6WB Combination 0.003 6 DL+0.6W16 Combination -0.001 6 0.6DL+0.6WA Combination -0.003 6 0.6DL+0.6WB Combination 0.003 6 DL+0.75(SN+0.6WA) Combination -0.005 6 DL+0.75(SN+0.6WB) Combination 0.000 6 DL+0.75(SN+0.6W16) Combination -0.004 7 DL+SN Combination -0.001 7 DL+0.6WA Combination -0.001 7 DL+0.6WB Combination 0.001 7 ' DL+0.6W16 Combination 0.000 7 0.6DL+0.6WA Combination -0.001 7 0.6DL+0.6WB Combination 0.001 7 DL+0.75(SN+0.6WA) Combination -0.002 7 DL+0.75(SN+0.6WB) Combination 0.000 7 DL+0.75(SN+0.6W16) Combination -0.001 8 DL+SN Combination 0.000 8 DL+0.6WA Combination 0.000 8 DL+0.6WB Combination 0.000 8 DL+0.6W16 Combination 0.000 8 0.6DL+0.6WA Combination 0.000 8 0.6DL+0.6WB Combination 0.000 8 DL+0.75(SN+0.6WA) Combination 0.000 8 DL+0.75(SN+0.6WB) Combination 0.000 8 DL+0.75(SN+0.6W16) Combination 0.000 HW Engingering Job #17206 0.156 -0.226 0.003 -0.165 -0.074 -0.072 0.072 -0.033 -0.071 0.073 -0.108 0.000 -0.079 0.055 0.000 0.004 -0.009 -0.001 0.003 0.041 0.044 0.034 0.043 -0.054 0.062 -0.042 -0.055 0.061 -0.009 0.078 0.000 0.107 0.000 0.007 -0.018 -0.001 0.006 0.079 0.084 0.065 0.044 -0.054 0.061 -0.041 -0.054 0.060 -0.008 0.078 0.001 -0.034 0.062 0.010 0.047 0.026 0.020 -0.016 0.010 0.019 -0.018 0.034 0.006 0.026 0.099 0.033 -0.025 0.005 0.031 -0.027 0.096 0.053 0.076 0.146 0.020 -0.010 -0.011 0.017 -0.012 0.121 0.099 0.098 0.208 0.074 -0.063 0.013 0.071 -0.067 0.208 0.105 0.162 0.143 0.017 -0.007 -0.012 0.015 -0.009 0.117 0.099 0.095 10/03/2017 15/18 E Joint OutputCase CaseType Fl F2 F3 E ,r, Kip Kip Kip 9 DL+SN Combination 0.001 0.107 0.208 9 DL+0.6WA Combination 0.001 0.000 0.074 9 DL+0.6WB Combination -0.001 0.007 -0.063 9 DL+0.6W16 Combination 0.000 -0.018 0.013 9 0.6DL+0.6WA Combination 0.001 -0.001 0.071 9 0.6DL+0.6WB Combination -0.001 0.006 -0.067 9 DL+0.75(SN+0.6WA) Combination 0.002 0.079 0.208 9 DL+0.75(SN+0.6WB) Combination 0.000 0.084 0.105 9 DL+0.75(SN+0.6W16) Combination 0.001 0.065 0.162 10 DL+SN Combination 0.004 0.043 0.146 10 DL+0.6WA Combination 0.003 -0.054 0.020 10 DL+0.6WB Combination -0.003 0.062 -0.010 10 DL+0.6W16 Combination 0.001 -0.042 -0.011 10 0.6DL+0.6WA Combination 0.003 -0.055 0.017 10 0.6DL+0.6WB Combination -0.003 0.061 -0.012 10 DL+0.75(SN+0.6WA) Combination 0.005 -0.009 0.121 10 DL+0.75(SN+0.6WB) Combination_ 0.000 0.078 0.099 10 DL+0.75(SN+0.6W16) Combination 0.004 0.000 0.098 11 DL+SN Combination -0.008 0.055 0.099 11 DL+0.6WA Combination -0.006 0.000 0.033 11 DL+0.6WB Combination 0.007 0.004 -0.025 11 DL+0.6W16 Combination -0.003 -0.009 0.005 11 0.6DL+0.6WA Combination -0.006 -0.001 0.031 11 0.6DL+0.6WB Combination 0.007 0.003 -0.027 11 DL+0.75(SN+0.6WA) Combination -0.011 0.041 0.096 11 DL+0.75(SN+0.6WB) Combination -0.001 0.044 0.053 11 DL+0.75(SN+0.6W16) Combination -0.008 0.034 0.076 HW Engingering Job #17206 10/03/2017 16/18 10/03/2017 Connection Check Awning top to wall attachment check (E/P3) maximum reaction from analysis VREc := 0.21 kip TREc := 0.11 kip using worst case reaction attachment horizontal spacing in model d := 27.5 in attachment horizontal trib..length D := 32 in attachment vertical spacing in model s := 35 in attachment vertical spacing S := 33 in 12 Vmax VREC d Tmax TREC d S Vmax = 244 lbf Tmax = 136 lbf Use 1/4" ITW Buildex TEK or equivalent screw for frame to Z bracket Va := min( 10631bf 35 ,990 lbf I Ta := 335lbf 35 Va = 827 lbf Ta = 261 lbf ESR -1976 45 / 45 Screw demand/capacity ratio n := 1 Ratio := max l Vmax Tmax Vmax + 0.71 Tmaxl :Va' nTa nVa :Tall check := if(Ratio <_ 1.0, "sufficient" , "NG" ) Use 3/8" lag screw for z bracket to wood block(by others) 2 2 max Tmax + Vmax Zpenp := 180 lbf max = 280 lbf Zpar := 280 lbf Ratio = 0.665 check = "sufficient" maximum force to screws W := 305 Ibf in Tmax CD := 1.6 for wind CM := 1.0 Co := 1.0 Ct := 1.0 Cg := 1.0 0 := atan(—) Vmax Z1 := Zpenp CD CM CA Ct Cg Z1 = 288 lbf Z2 := Zpar CD CM Co Ct Cg Z2 = 448 lbf Z1 Z2 Z ZI cos(0)2 + Z2 sin(0)2 WI := W T_E CD CM Ct 1W1 Z Ze :– W1 cos(0)2 + Z sin(0)2 Z = 396.1 lbf W 1 = 0.488 kip Ze = 415 lbf check := if(Pmax < Ze , "Lag screw is Ok" , "NG" Awning bottom to wall attachment check (F/P3) maximum reaction from analysis VREc := 0.1 kip TREc := 0.16 kip T_E := 1 in penetration into wood for a conservative design check = "Lag screw is Ok" using worst case reaction HW Engingering Job #17206 17/18 attachment horizontal spacing in model d := 55 in attachment horizontal trib. length D := 64 in attachment vertical spacing in model s := 35 in attachment vertical spacing S := 33 in Vmax VREc d Tmax TREC d S Vmax = 116 lbf Tmax = 197 lbf Use 1/4" ITW Buildex TEK or equivalent screw for frame to Z bracket Va:= min(10631bf 35,990 1bf I Ta:= 3351bf 35 45 j 45 Screw demand/capacity ratio n := I C Vmax Tmax Vmax Tmax\ Ratio := max ' + 0.71 nVanTa nVa nTaj check := if(Ratio <_ 1.0, "sufficient" , "NG" ) Use 3/8" laq screw for z bracket to wood block(by others) Pmax JTmax2 + Vmax2 Zpenp := 180 lbf Pmax = 229 lbf Zpar := 280 lbf Va = 827 Ibf 10/03/2017 Ta = 261 lbf ESR -1976 Ratio = 0.758 check = "sufficient" maximum force to screws W := 305 lbf in CD := 1.6 for wind CM := 1.0 Co := 1.0 Ct := 1.0 Cg := 1.0 0 := atan ZI := Zpenp CD CM CA Ct Cg Z1 = 288 lbf Z2 := Zpar CD CM CO Ct Cg Z2 = 448 lbf Z1 Z2 Z Z = 317.2 lbf T_E := 1 in penetration into wood for Z1 cos(0)2 + Z2 sin(0)2 W1:= W T_E CD CM C1 Tmax Vmax Ze IW1 Z W1 cos(0)2 + Z sin(0)2 WI = 0.488 kip Ze = 429 lbf check := if (Pmax < Zg , "Lag screw is Ok" ,"NG") Frame to frame Use typical 1/8" all around fillet shop weld, well sufficient. a conservative design check = "Lag screw is Ok" HW Engingering Job #17206 18/18 0 City of Tukwila Allan Ekberg, Mayor Department of Community Development. September 22, 2017 LUKE WALKER 18375 OLYMPIC AVE S TUKWILA, WA 98188 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0250 AT&T - 16415 SOUTHCENTER PKWY Dear LUKE WALKER, Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Allen Johannessen at 206-433-7163 if you have questions regarding these comments. • (GENERAL INFORMATION NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) "STAMP AND SIGNATURES" "Every page of a plan set must contain the seal/stamp, signature of the licensee(s) who prepared or who had direct supervision over the preparation of the work, and date of signature. Specifications that are prepared by or under the direct supervision of a licensee shall contain the seal/stamp, signature of the licensee and the date of signature. If the "specifications" prepared by a licensee are a portion of a bound specification document that contains specifications other than that of an engineering or land surveying nature, the licensee need only seal/stamp that portion or portions of the documents for which the licensee is responsible." It shall not be required to have each page of "specifications" (calculations) to be stamped and signed; Front page only will be sufficient. (WAC 196-23-010 & 196-23-020) (BUILDING REVIEW NOTES) 1. Additional information shall be required for the awning installation. A registered design professional or engineer shall provide details for the awning construction with calculations. Information shall include type of building and building exterior materialsthe awning shall be attached too and where the method of attachment meets code to withstand wind or other loads and live loads as required by Chapter 16 of the 2015 IBC. Structural members shall be protected to prevent deterioration. Awnings shall have frames of noncombustible material, fire -retardant -treated wood, wood of Type IV size, or 1 -hour construction with combustible or noncombustible covers. Awnings and canopies shall be provided with an approved covering that meets the fire propagation performance criteria of Test Method 1 or Test Method 2, as appropriate, of NFPA 701 or has a flame spread index not greater than 25 when tested in accordance with ASTM E 84 or UL 723. Provide the additional information that applies to this awning installation to show compliance with the related code information described above. (2015 IBC SECTION 3105) 2. Provide and be specific about the types of materials, fasteners, hardware, and awning covering specifications to meet code for non-combustible material. Note: Contingent on response to these corrections, further plan review may request for additional corrections. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 0 0 In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. D17-0250 REAL 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORS COPY ° PLAN REVIEW/ROUTING SLIF PERMIT NUMBER: D17-0250 PROJECT NAME: AT&T DATE: 10/04/17 SITE ADDRESS: 16415 SOUTHCENTER PKWY Original Plan Submittal X Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: roll Building Division Public Works Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 10/05/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/02/17 ~ Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: 'Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: 12/18/2013 GERMIT CORD COPY C PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0250 DATE: 09/18/17 PROJECT NAME: AT&T SITE ADDRESS: 16415 SOUTHCENTER PKWY X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: GM- utldtng Divisio tirt Public Works t 64 Fire Prevention Structural Planning Division Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 09/19/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: Approved with Conditions Denied (ie: Zoning Issues) 10/17/17 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg (N' Fire ❑ Ping ❑ PW ❑ Staff Initials: v �� 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through Phe mail, fax, etc. Date: 0 ((/ Plan ChecWPermit Number: D17-0250 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: AT&T Project Address: 16415 Southcenter Pkwy Contact Person: 1,44(' VIS q, t ia / Phone Number: - 92c— q8/ - /21V Summary of Revision: O/Rwi4,7 A./% #4 a V Sfi*Mfect by u. cedgarti yf► # v1#( 411114- eft ,ite1 {(. carAtte ckS L RECEIVED CITY OF TUKWILA OCT 0 4 i3Oi/ PERMIT CEMER Sheet Number(s): j -"--1 "Cloud" or highlight all areas of revision including date of revisio Received at the City of Tukwila Permit Center by: [Entered in TRAKiT on 1(9 —1 \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: RAINIER INDUSTRIES LTD Hoene 1"ispanol Contact Safety & Health Claims & Insurance CaWashington State Department of Labor & Industries C Page 1 of 3 A -Z Index Help My L&t Workplace Rights Trades & Licensing RAINIER INDUSTRIES LTD Owner or tradesperson Principals CAMPBELL, SCOTT CURTICE, PRESIDENT CAMPBELL, KAREN LYNN, VICE PRESIDENT SCHOONMAKER, GEORGE W (End: 01/01/1980) SCHOONMAKER, GEORGE W, AGENT (End: 01/01/1980) Doing business as RAINIER INDUSTRIES LTD WA UBI No. 600 523 816 18375 OLYMPIC AVE S TUKWILA, WA 98188 425-251-1800 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties - Awnings, Canopies, Patio Covers, Exterior Screens License no. RAINIIL066QP Effective — expiration 11/17/1994— 01/11/2019 Bond CBIC Bond account no. LB6600 $6,000.00 Received by L&I Effective date 09/16/2002 10/01/2002 Expiration date Until Canceled Insurance Phoenix Insurance Company, The $1,000,000.00 Policy no. 6300532991 Received by L&l Effective date 01/24/2017 12/31/2016 Expiration date 12/31/2017 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600523816&LIC=RAINIIL066QP&SAW= 10/9/2017