Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D17-0083 - BOEING #2-81.2 - 2ND FLOOR TENANT IMPROVEMENT
BOEING #2-81.2 8123 E MARGINAL WAY S D17-0083 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT 0001600020 8123 EAST MARGINAL WAY S Project Name: BOEING #2-81.2 Permit Number: Issue Date: Permit Expires On: D 17-0083 5/15/2017 11/11/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 JOHN S MURDOCH PO BOX 3707 MC 46-88 , SEATTLE, WA, 98124 BOEING COMPANY, THE 100 N RIVERSIDE, M/C 5003-4027 , CHICAGO, IL, 60606-1596 BOEINC*294ML Lender: Name: BOEING COMPANY THE Address: PO BOX 3707 M/C 46-88 PROPERTY TAX DEPT, SEATTLE, WA, 98124 Phone: (253) 740-0214 Phone: (312) 544-2535 Expiration Date: 1/18/2019 DESCRIPTION OF WORK: TENANT IMPROVEMENT OF 42,915 INTERIOR ONLY ON 2ND FLOOR OF THE 2-81 BUILDING. DEMO OF REMOVAL OF FLOOR/CEILING FINISH MAERIALS. REMOVAL OF NON LOAD BEARING WALLS. PLUMBING/SPRINKLERS/ELECTRICAL/MECHANICAL UNDER SEPARATE PERMITS. TENANT IMPROVEMENT WILL INCLUDE NEW WALLS, CEILING TILES AND FLOOR COVERINGS. Project Valuation: $1,251,000.00 Type of Fire Protection: Sprinklers: YES Fire Alarm: NO Type of Construction: IIB Electrical Service Provided by: TUKWILA Fees Collected: $17,189.67 Occupancy per IBC: B Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015. 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Number: 0 No Fill: 0 Permit Center Authorized Signature: 11/d,' /� Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or loc. s re lating construction or the performance of work. I am authorized to sign and obtain this developme .Ir i a d agree to the conditions attached to this permit. Signatur Print Na Date: & / -V " This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: New suspended ceiling grid and light fixture installations shall meet the seismic design requirements for nonstructural components. ASCE 7, Chapter 13. 5: Partition walls shall not be tied to a suspended ceiling grid. All partitions greater than 6 feet in height shall be laterially braced to the building structure. Such bracing shall be independent of any ceiling splay bracing. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 13: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (3A, 40B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 5.4) 9: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand- held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 10: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 11: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 7.2, 7.3) 14: Maintain fire extinguisher coverage throughout. 15: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 16: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the' door handle is engaged from inside the tenant space. (IFC Chapter 10) 17: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 18: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.9.1) 19: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) C 20: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.6) 21: Aisles and aisle access ways serving as a portion of the exit access in the means of egress system shall comply with the requirements of this section. Aisles or aisle access ways shall be provided from all occupied portions of the exit access which contain seats, tables, furnishings, displays and similar fixtures or equipment. The required width of aisles shall be unobstructed. (IFC 1017.1) 22: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1011.6.3) 23: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.3.1) 27: Fire protection systems shall be maintained in accordance with the original installation standards for that system. Required systems shall be extended, altered or augmented as necessary to maintain and continue protection whenever the building is altered, remodeled or added to. Alterations to fire protection systems shall be done in accordance with applicable standards. (IFC 901.4) 25: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide. (NFPA 13-8.6.5.3.3) 24: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2436). 29: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2437) 28: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 30: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 31: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 32: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.9 of the International Building Code. 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 33: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 34: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 0611 EMERGENCY LIGHTING 1400 FIRE FINAL 0 0409 FRAMING 0606 GLAZING 4034 SI -METAL PLATE CONN 4026 SI-STRUCT STEEL 4004 SI -WELDING 0601 WALL INSULATION C CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Building Permit No. 11— COU Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION -0 I pE-j /✓C. f' ry '%r/(AaboeRggrs King Co Assessor's Tax No.: 000160-0020 Site Address: 7755 East Marginal Way So Tenant Name: The Boeing Company Suite Number: New Tenant: PROPERTY OWNER Name: The Boeing Company - John S. Murdoch Address: P.O. Box 3707 M/C 46-88 City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: John S. Murdoch - The Boeing Company Address: P.O. Box 3707 M/C 46-88 City: Seattle State: WA Zip: 98124 Phone: (253) 740-0214 Fax: Email: john.s.murdoch@boeing.com GENERAL CONTRACTOR INFORMATION Company Name: The Boeing Company Address: P.O. Box 3707 M/C 46-88 City: Seattle State: WA zip: 98124 Phone: (253) 740-0214 Fax: Contr Reg No.: BOEINC*294ML Exp Date: 01/18/2019 Tukwila Business License No.: H:\Applicntions\Fonns-Apphentions On Line12011 Applicntions\Pemit Application Revised - 8-9-11.doex Revised: August 2011 bh 2-91 Floor: ❑ Yes ..No 2 ARCHITECT OF RECORD Name: The Boeing Company Company Name: Buffalo Design Company Name: Architect Name: Chris E. Carlson Address: 1520 4th Ave Suite 400 City: Seattle State: WA zip: 98101 Phone: (206) 467-6306 Fax: Email: lroberts@buffalodesign.com State: ENGINEER OF RECORD Name: The Boeing Company Address: P.O. Box 3707 M/C 46-88 Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: The Boeing Company Address: P.O. Box 3707 M/C 46-88 City: Seattle State: WA Zip: 98124 Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 1,251,000 Existing Building Valuation: $ 25,000,000 Describe the scope of work (please provide detailed information): Tenant Improvement of 42,915 Interior only on 2nd floor of the 2-81 Building. Demo of Removal of Floor/Ceiling Finish Materials. Removal of Non Load Bearing Walls. Plumbing/Sprinklers/Electrical/Mechanical under Separate Permits. T.I. will include New Walls, Ceiling Tiles and Floor Coverings. Will there be new rack storage? ❑ Yes Z.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq fl): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ® No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Z No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. _ SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonts-Applications On Line \2011 Applicatiors\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s` Floor 62,828 2'd Floor 62,828 42,915 II -B B 3'd Floor M€ 1,265 Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq fl): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes ® No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes Z No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. _ SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fonts-Applications On Line \2011 Applicatiors\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 C PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): D.N.A. Call before you Dig:, 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet Water District ❑ ...Tukwila ❑ ...Water District #125 ❑ ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate ❑ .. Highline ❑ ... Valley View 0 .. Renton 0...Sewer Availability Provided ❑ .. Renton ❑ .. Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) 0 ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): 0 ...Right-of-way Use - Nonprofit for less than 72 hours 0 ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ...Total Cut cubic yards ❑ ...Total Fill cubic yards ❑ ...Sanitary Side Sewer 0 ...Cap or Remove Utilities 0 ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑. ❑. ❑. 0 0 .. Geotechnical Report ❑ .. Maintenance Agreement(s) ❑ ...Traffic Impact Analysis ❑ ...Hold Harmless — (SAO) ❑ ... Hold Harmless — (ROW) 0 .. Right-of-way Use - Profit for less than 72 hours 0 Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage . Abandon Septic Tank . Curb Cut . Pavement Cut . Looped Fire Line ❑ ...Permanent Water Meter Size... ❑ ...Temporary Water Meter Size .. ❑ ...Water Only Meter Size ❑ ...Sewer Main Extension Public 0 ❑ ...Water Main Extension Public 0 31 ❑ .. Grease Interceptor ❑ .. Channelization 0 .. Trench Excavation ❑ .. Utility Undergrounding WO # WO # WO # ❑...Deduct Water Meter Size Private 0 Private 0 FINANCE INFORMATION Fire Line Size at PropertyyLine Number of Public Fire Hydrant(s) 0 ...Water 0 ...Sewer 0 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: Water Meter Refund/Billing: Name: Mailing Address: City State Zip Day Telephone: City State Zip H:\Applications\Fors-Applications On Linc\2011 Applicatiotu\Penuit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). - I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF 'E' RY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING Signature: 7.-W° Atv bran I Date: 04/10/2017 Mailing Address: P.O. Box 3707 M/C 46-88 H:\ApplicationsWorms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docc Revised: August 2011 bh Day Telephone: (253) 740-0214 Seattle WA 98124 • City State Zip Page 4 of 4 DESCRIPTIONS ACCOUNT PermitTRAK QUANTITY PAID $17,189.67 D17-0083 Address: 7755 EAST MARGINAL WAY S Apn: 0001600020 $17,189.67 Credit Card Fee $500.67 Credit Card Fee R000.369.908.00.00 0.00 $500.67 DEVELOPMENT $16,198.28 PERMIT FEE R000.322.100.00.00 0.00 $9,814.41 PLAN CHECK FEE R000.345.830.00.00 0.00 $6,379.37 WASHINGTON STATE SURCHARGE 8640.237.114 0.00 $4.50 TECHNOLOGY FEE $490.72 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11239 R000.322.900.04.00 0.00 $490.72 $17,189.67 Date Paid: Monday, April 10, 2017 Paid By: JOHN MURDOCH THE BOEING COMPAN Pay Method: CREDIT CARD 079546 Printed: Monday, April 10, 2017 11:01 AM 1 of 1 CPPSYSTEMS INSPECTION RECORD D)7 -meq Retain a copy with permit INSPECTION NO. PERMIT NO.' t CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: la`1.& a-8) a2 Type of Inspection: <Nil.1)IN6 F1 W - Address: 6123 , . W - all Date Called: Special Instructions: 'Date Wanted:.ii. 1-2/0 `gyp p.m. Requester: f C l G' 431 NG b/ f 77Z M Phone No: 253 ,'f S'5 !2 bcApproved per applicable codes. 0 Corrections required prior to approval. COMMENTS: caC- I3U;LDI C- Ni Inspector: Date: /2(,a REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection, INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 b17-64063 Project: B'l Type of Inspection: &ILDBNCs .em -L. Address: 8123 .a- n ix-r..lir-r.. Date Called: Special Instructions: c ' I, ._ Date Wanted: /0-17-7 a.m. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: PC, eV"18/* - Inspector: sc Date: / % /7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 TD/7-m63 Projecl,4, 1016.6. NG- Type of Inspection: .5145PEAJDab C. l LJ7U- Address: g/23.', ,',%4"4-L Date Called: 5, Special Instructions: -63.1,2, <41-6-L- eV ftt Date Wanted: a.m. /o-/2.17 Requester: i-Rl.c Phone No: � 7-63-3n- /Re,°,a ❑ Approved per applicable codes. El Corrections required prior to approval. COMMENTS: p/jt. -.511.5- to/ 727 c_'/z/ Inspector: Date: /0 7/2 •// REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION N0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 D!7- 0063 Prot: 4 E/.s& 2601.2 Type of pection: mArc- ,1 -# i ro* (WOR'T`a Ca,ofrRaler, 6 K - X/ SiDi ' e SUdc.Df'ts(c Address: 8/03 C rWeeri i ii)') S Dat Called: Special Instructions: •Date Wan„ 2,1;7 ;; Requeste . t A`/d JC Phone No: We Liz.':. 0/416 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ®" j e244(...- ei6 / L/ NG- FRA-evo NG ecvo 'l jal W N /. of» ,1 -# i ro* (WOR'T`a Ca,ofrRaler, 6 K - X/ SiDi ' e SUdc.Df'ts(c Inspector: -2/ Date: � 7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 (206) 431-3670 Project: ....4*- )3 5 f 2- 61 2 Type Inspection: -f-m Pt) i Nty, A dress: 6123 C illAVidATAZ,w) S Date Called: Special Instructions: `�1=� Date d: e3 /7` a.m. RequeW ess r: '-J lltl%t 1%1✓e- Phone No: _ ZO6 423 .0/11 Approved per applicable codes. COMMENTSC- - ['Corrections required prior to approval. Inspector: Date: 1,-21-17 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 0 INSPECTION NO. CITY OF TUKWILA BUILDING 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 INSPECTION RECORD Retain a copy with permit PERMIT NO. DIVISION (206) 431-3670 Pro'e-6,Act: U ;! )J i Z -" 2 Type of Inspection:(1't`�.{'�t ^ �,j L //vS77 Address: 9/238 /44. tjV� Date Called: Special Instructions: Date Wante d: .� f i "7 p.m. Requester: Phone No: - Approved per applicable codes. Corrections required prior to approval. COMMENTS: /01,4_4770/1/ Inspector: Date: 23-) 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit D, 7 - 00E0 3 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Projer i�f�6/Av6- 2 -09/r Z Typspection: �//�. 141' .- Address: 123 r if/ARO/1L- (i. Date Called: Special Instructions: Date Waannte{�: l 1p 2.®/ / 7i rr p.m. Request : Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: c7K- v, f NG -- Inspector: G— Inspector: 7i? Date: REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 1)l? -,OD d3 PERMIT NUMBERS CITY OF TUKWILA.FIRE DEPARTMENT 206-575-4407 Project: gz01,-) '61 - / Type of Inspection: tz....t,„ k_,1E....R____ Address: Q (,Z „` Suite #: t EM Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: O 64 O(, %1!i2 -n4 r?_ -rN 4, ✓L r� lc -C �-YL I 1' r 7 5/6/•76.--D 5 ^v4 / ,4$ Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:,. �i4--- Date: (,1/q / 9 Hrs.: r 1 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 Lighting Summary LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Info Compliance forms do not require a password to use. Instructional and calculating cells are write - protected. Project Title: 2.81 & Density Improvements Date 9/6/2017 Applicant Information. Provide contact information for individual who can respond to inquiries about compliance form information provided. For Building Department Use FILE Company Name: SAZAN Group Company Address: 600 Stewart St., Suite 1400 Applicant Name: Sazan Group, Attention: Elmo Acacio, PE/Loreli Floresca Applicant Phone: (206) 267-1700 Applicant Email: eacacio@sazan.com Project Description with ■ New Building ■ Addition El Alteration ■ Plans Included Include PROJ-SUM form (included in envelope forms workbook) lighting compiliance forms. Building Additions Refer to Section C502.2.6 for additional requirements. Compliance Method Interior lighting Exterior lighting Lighting systems in addition area comply with all applicable provisions as a stand alone new construction project ■ ■ Lighting systems in addition are combined with existing building lighting systems to demonstrate compliance L 19 ■ Addition is combined with existing: For interior lighting projects, include new + existing interior lighting fixture wattage in Proposed Lighting Wattage table in LTG -INT -BLD or LTG -INT -SPACE form. For exterior lighting projects, include new + existing exterior lighting fixture wattage in Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG -EXT form. Interior and Exterior Lighting Alterations Select all Lighting Power Control elements that of the retrofit project. If combination of spaces 50% of the existing fixtures in some spaces, and fixtures are replaced in provide separate lighting compliance forms for conditions. Spaces undergoing type of retrofit maybe lighting power compliance to S:; "4' _ • requir- qi. 'sp. �•0 B.AC40,/,., All =rata i ., •littoli m - missio'r ± .er -4 1 Rr ICity ✓�, r44" 1ST' S 1 t I. and Lighting apply to the scope project includes a where less than are replaced 50% or more of the others, then power the two retrofit the same combined into one form. . � . ditional -- j slid!! b . 0New © " 5O r5. "' ," „ , .�. '" ' ' • eing made to lighting space are not Lighting Power Interior lighting Parking garage Exterior lighting 50% or more of existing are replaced i ■ ■ Less than 50% of existing are replaced ■ ■ ■ Lamp and/or ballast replacement only — existing total wattage not increased ■ ■ ■ 50% or more replaced - Total lighting power of new + existing -to -remain LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to Lighting Wattage table in LTG-iNT-BLD, LTG -INT -SPACE or LTG -EXT Less than 50% replaced - Total lighting power of new + existing -to -remain total lighting power prior to alteration. Include new + existing -to -remain Wattage table in LTG -INT -BLD, LTG -INT -SPACE or LTG -EXT form. 50% threshold applies to number of luminaires for interior spaces .3 installed wattage for exterior luminaires. fixtures shall comply with total -remain fixtures in Proposed form. fixtures shall not exceed the fixtures in the Proposed. Lighting - I j� �n - `i' es, 7fd totttll'.i�Refer • INMPLIANCE Lighting Controls Interior lighting P_ king gar gam' P Yg4iting wiring installed to serve added ! ,(til 1l •y fixtures and/or fixtures relocated to new ■ ■ MAY : circuit(s) of Tul6ila It N ■ lighting li New or movedgng panelii+ Interior space is reconfigured - • ■ luminaires unchanged or relocated only New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7. New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic time switch controls per C405.2.2. Reconfigured interior space - Provide all required lighting controls that apply to a new interior space. Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces. ■ No changes are the interior or exterior systems and existing uses and configuration changed. Change of S VED CIrlf OF TUKWIL.4 APR 10 2017 change in space use are upgraded to or C405.4.2(2). Code in Proposed Lighting Wattage table a Existing interior lighting systems in areas under -going a comply with LPAs for the new space types per Tables C405.4.2(1) Identify interior spaces requiring LPD upgrade to the current in LTG -INT -BLD or LTG -INT -SPACE form. PERMIT CENTER DrFoot5 Lighting Summary, cont. LGT-SUM 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: 2.81 & Density Improvements Date 4/6/2017 Interior Lighting System Description Interior Lighting Power Allowance Method ■ Building Area Method 19 Space -by -space Method Select method used in project. Interior Lighting Controls El All C405.2.1 - C405.2.8 Controls • C405.2 Exception 5 Luminaire Level Lighting Control (LLLC) • Additional Efficiency Package Option C406.4 Enhanced digital lighting controls To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the required controls per C406.4. Dwelling Unit Interior Lighting Permanently installed interior lighting fixtures in dwelling units comply with: Q 0 C405.2 thru C405.5 Commercial Lighting Controls and LPA © C406.3 High Efficacy Lighting 0 Exterior Lighting System Description Interior Lighting - Space -By -Space Method LTG -INT -SPACE 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: 2.81 & Density Improvements Date 4/6/2017 Calculation Area NOTE 9 0 O Addition - O Addition stand alone + existing O Spaces where < 50% of O Spaces where >_50% of o luminaires are replaced luminaires are replaced For Building Department Use LPA Calculation Type Q Standard 0 Additional Efficiency Package Option 0 C406.3 Reduced Interior Lighting Power To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA. Refer to C406.3 for additional requirements. Maximum Allowed Lighting Wattage NOTE1 Location (plan #, room #) Space Type Ceiling Height NOTE 2 Gross Interior Area in ft2 Allowed Watts per ft2 Watts Allowed (watts/ft2 x area) 2nd floor Office: Open plan 10 34572 0.796 27505 2nd floor Corridor: all other 10 1399 0.530 739 2nd floor - multi- spaces Conference/meeting/multipurpose 10 4535 0.980 4494 plot room Copy/print room 10 112 0.580 65 Lobby Art/Exhibit Display Allowance from LTG -INT -DISPLAY NOTE 8 Total Area Retail Display 40613 LTG -INT -DISPLAY Allowed Watts Allowance from 32754 Proposed Lighting Wattage "OTE3 Location (plan #, room #) open office corridor&collaborati on area corridor Fixture Description NOTE 4, 5, 6 RL1 - 2x4 LED recessed fixtures Number of Fixtures 516 Watts/ Fixture NOTE 7 27 RL3 - 4" LED recessed downlight RL1 - 2x4 LED recessed fixtures 29 collaboration area collaboration area collaboration area conference rms conference rms conference rms conference mis plot room UL1 - LED Undercabinet fixture HL2 - LED pendant mounted fixture RL5 - 3" LED Aperture Linear recessed luminaire RL1-2x4 LED recessed fixtures RL3 - 4" LED recessed downlight HL1 - LED pendant fixture RL2 - Recessed linear LED wall wash RL1 - 2x4 LED recessed fixtures 10 3 5 1 6 8 93 108 1 10 27 7 15 130 27 10 38 9 27 Watts Proposed 13932 290 270 21 75 130 162 80 1634 972 27 Proposed Retail Disp ay Lighting from LTG -INT -DISPLAY Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 17593 Interior Lighting Power Allowance COMPLIES Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category per from drop down menu. Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f. Note 3 List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures. Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank. Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing in fixture description. Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For luminaires with screw-in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50 watts/lineal foot, or enter the wattage limit of permanent current limiting device. Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Note 9 - Calculation Area Details: a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building lighting systems to demonstrate compliance. Refer to C502.1. b. For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types and gross interior areas. c. If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided Lighting, Motor, and Electrical Permit Checklist, Pg. 1 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: 2.81 & Density Improvements Date 4/6/2017 The following information is necessary to check a permit application for compliance with the lighting, motor; and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes LIGHTING CONTROLS Yes C405.2 Lighting controls, general For all lighting fixtures, indicate lighting control method on plans for spaces and lighting zone(s) served, or exception taken see plan drawings NA C405.2 Luminaire level lighting controls (LLLC) Indicate on plans all fixtures provided with LLLC in lieu of C405.2 lighting controls; provide description of control capabilities and performance parameters NA C405.1 Lighting in dwelling units For permanently installed lighting fixtures in dwelling units, indicate lighting control method on plans for spaces and lighting zone(s) served, or demonstrate compliance with high efficacy exception Yes C405.2.3 C405.2.1.1 C405 2 2 2 Manual controls Indicate on plans the method of manual lighting control (whether combined with occupancy sensor, automatic light reduction, daylight responsive or specific application controls), location of manual control device and area or specifice application it serves see plan drawings C405.2.4 C405.2.5 Yes C405.2.2.1 C405 2 2 2 Manual interior lighting controls Indicate on plans which method of manual 50% lighting load reduction is provided, or whether lighting load is reduced via occupancy sensors or daylight responsive controls see plan drawings C405.2.3 Yes C405.2.2 Method of automatic shut-off control Indicate on plans the method of automatic shut-off control during unoccupied periods (occupancy sensor or time switch) for all lighting zones; see plan drawings Indicate locations where automatic shutoff is provided by other methods (occupancy sensor or digital timer switch) or which time switch control exception applies see plan drawings Yes C405.2.1 C405.2.1.1 Occupancy sensor controls Indicate on plans the spaces served by occupancy sensors; Indicate whether occupancy sensor controls are configured to be manual -on, automatic 50% -on, or serve a space eligible for automatic 100% -on per exception see plan drawings NA C405.2.1.2 Occupancy sensor controls - warehouses Indicate aisleways and open areas in warehouse spaces provided with occupancy sensor controls that reduce lighting power by 50% NA C405.2.6 Digital timer switch Indicate required digital timer switch control function when control is used Yes C405.2.2.1 Automatic time switch controls Indicate locations of override switches on plans and the lighting zone(s) served, include area sq. ft. see plan drawings NA C405.2.4.2 C405.2.4.3 Daylight zones - Sidelight and toplight Indicate primary and secondary sidelight daylight zone areas on plans, include sq. ft.; Indicate toplight daylight zone areas on plans, include sq. ft; For small vertical fenestration assemblies (rough opening less than 10 percent of primary daylight zone) where daylight responsive controls are not required, provide fenestration area to daylight zone calculation(s) NA C405.2.4 Daylight responsive controls Indicate on plans lighting zone(s) served by daylight responsive controls; Identify sidelight and toplight daylight zones that are not provided with daylight sensing controls and the exception(s) that apply; Indicate on plans the lighting load reduction method - continuous dimming, or stepped dimming that provides at least two even steps between 0%-100% of rated power; Indicate that daylight sensing controls are configured to completely shut off all controlled lights in the lighting zone NA C405.2.5 Additional controls Specific application lighting controls Identify spaces and lighting fixtures on plans that require specific application lighting controls per this section NA C405.2.5 - Items 1&2 Display and accent lighting Indicate on plans that display and accent lighting, and display case lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate manual and automatic lighting control method Lighting, Motor, and Electrical Permit Checklist, Pg. 2 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: 2.81 & Density Improvements Date 4/6/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents - Location in Documents Building Department Notes NA C405.2.5 - Item 3 Hotel/motel guest rooms Indicate method of automatic control - vacancy or captive key control of all installed luminaires and switched receptacles in guest room NAcontrol C405.2.5 - Item 4 Supplemental task lighting Indicate method and location of automatic shut-off vacancy for supplemental task lighting, including under -shelf or under -cabinet lighting NA C405.2.5 - Item 5 Lighting for non- visual applications Indicate on plans eligible non -visual lighting applications, include sq. ft. area of each lighting control zone; Indicate on plans that non -visual lighting are controlled independently from both general area lighting and other lighting applications within the same space; Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 6 Lighting equipment for sale or demonstration Indicate on plans that lighting equipment for sale or demonstration are controlled independently from both general area lighting and other lighting applications within the same space; _. Indicate method of manual lighting control and applicable automatic lighting control NA C405.2.5 - Item 7 Means of egress lighting Identify on plans egress fixtures that function as both normal and emergency means of egress illumination; Provide calculation of lighting power density of total egress lighting; If total egress lighting power density is greater than 0.02 W/sq. ft., indicate on plans egress fixtures requiring automatic shut-off during unoccupied periods; Indicate method of automatic shut-off control NA C405.2.7 Exterior lighting controls Indicate on exterior lighting plans and fixture schedules the automatic lighting control method, control sequence, and locations served; For building fat;ade and landscape lighting, indicate automatic controls shut off lighting as a function of dawn/dusk and fixed opening/closing time; For all other exierior lighting, indicate automatic controls shut off lighting as a function of available daylight; include control sequence that also reduces lighting power by at least 30% between 12am-6am, or from 1 hour after closing to 1 hour before opening, or based upon motion sensor NA C405.5.1 Exterior building grounds lighting controls For building grounds fixtures greater than 100 watts, indicate on plans whether fixtures have efficacy greater than 80 lumens or; are controlled by motion sensor, or are exempt lighting per C405.5.2 NA C405.2.5 Area controls - Master control switches and circuit power limit Indicate location(s) of master control switch(es) intended to control multiple independent switches; circuit breaker may not be used as a master control switch; Verify that no 20 amp circuit controlled by a single switch or automatic control is loaded beyond 80% NA C406.4 Enhanced digital lighting controls To comply with additional efficiency package option, indicate on plans all interior lighting fixtures that are individually addressed and provided with continuous dimming, or exception taken; Include calculation of percent total installed interior lighting power that is configured with required enhanced lighting control functions (min 90% to comply with additional efficiency package option) NA C405.13 C408.3 Lighting system functional testing If claiming lighting system commissioning exemption provide supporting calculation; Identify applicable commissioning documentation requirements per Section C408 or eligibility for exception; Provide written procedures for functional testing of all automatic controls and describe the expected system response Lighting, Motor, and Electrical Permit Checklist, Pg. 3 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all R1 Revised July 2016 Project Title: 2.81 & Density Improvements Date 9/6/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes INTERIOR LIGHTING POWER & EFFICACY Yes C405.4.1 C405.4.1 C405.4.2 Total connected interior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; see plan drawings Identify spaces eligible for lighting power exemption on plans and in compliance forms; indicate the exception applied; Identify lighting equipment eligible for lighting power exemption in fixture schedule and in compliance forms; indicate the exception applied; Indicate that exempt lighting equipment is in addition to general area lighting and is controlled independently Yes C405.3 Exit signs Indicate location of exit signs on plans and rated watts per fixture in lighting fixture schedule (maximum 5 watts per fixture) see plan drawings NA C405.1 Lighting in dwelling units - lamp efficacy If high efficacy exception is applied to permanently installed lighting fixtures in dwelling units, indicate in lighting fixture schedule if lamps in fixtures are high efficacy per R404.1. Calculate percentage of fixtures with high efficacy lamps in project (min 75% to comply with exception). NA C406.3 Reduced lighting power density - dwelling unit lamp efficacy For project with dwelling units, to comply with additional efficiency package option indicate in lighting fixture schedule if lamps in fixtures have efficacy rating of 60 lumens per watt or more. Calculate percentage of fixtures with lamps that have this o efficacy rating (min 95% to comply with option). Lighting Power Calculation - Indicate compliance path taken No C405.4.2.1 Building Area Method Complete required compliance forms — proposed wattage per building area does not exceed maximum allowed wattage per building area. Identify locations of building areas on plans Yes C405.4.2.2 Space -By -Space Method Complete required compliance forms — total proposed wattage does not exceed maximum allowed wattage. Identify locations of space types on plans, including retail display areas, lobby art & exhibit display areas, and ceiling heights as applicable see plan drawings C406.3 Reduced lighting power density To comply with additional efficiency package option, demonstrate in compliance forms that total connected interior lighting wattage is 75% less than the total maximum allowed lighting wattage via Building Area Method or Space -By -Space Method EXTERIOR LIGHTING POWER & EFFICACY NA C405.5.2 Total connected exterior lighting power Include all luminaires in lighting fixture schedule; indicate fixture types, lamps, ballasts, and manufacturer's rated watts per fixture; Identify exterior applications eligible for lighting power exemption on plans and in compliance forms; indicate exception applied; Indicate that exempt exterior lighting is controlled independently from non-exempt exterior lighting; include exception claimed for each fixture or group of fixtures under exception category NA Table C405.5.2(1) Exterior lighting zone Indicate building exterior lighting zone as defined by the AHJ NA C405.5.1 Exterior building grounds lighting For building grounds fixtures rated at greater than 100 watts that are complying based on efficacy, indicate rated lamp efficacy (in lumens per watt) in fixture schedule NA C405.5.2 Exterior lighting power calculations Complete required compliance form — proposed wattage for exterior lighting plus base site allowed does not exceed maximum allowed Lighting, Motor, and Electrical Permit Checklist, Pg. 4 LTG -CHK 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2, R3, R4 over 3 stories and all Ri Revised July 2016 Project Title: 2.81 & Density Improvements Date 4/6/2017 The following information is necessary to check a permit application for compliance with the lighting, motor, and electrical requirements in the Washington State Energy Code, Commercial Provisions. Applicability (yes,no,na) Code Section Component Compliance information required in permit documents Location in Documents Building Department Notes MOTORS & TRANSFORMERS C405.6 Electrical tranformers Include electrical transformer schedule on electrical plans; indicate transformer size, efficiency, or exception taken C405.7 Dwelling unit electrical energy consumption Indicate on electrical plans that each dwelling unit in Group R-2 has a separate electrical energy meter C405.8 Electric motor efficiency Include all motors, including fractional hp motors, in electric motor schedule on electrical plans; indicate hp, rpm, rated efficiency, or exception applied C405.9.1 Elevator cabs For luminaires in each elevator cab, provide calculated average efficacy of combined fixtures that indicates efficacy is not less than 35 lumens per watt; Indicate rated watts per cfm for elevator cab ventilation fans do not exceed 0.33 watts per cfm; Indicate automatic controls that de -energize lighting and ventilation fans when elevator is stopped and unoocupied for a period of 15 minutes or more C405.9.2 Escalators and moving walks Indicate escalators comply with ASME A17.1/CSA B44; automatic controls are configured to reduce operational speed to the minimum permitted when not in use C405.9.3 Regenerative drive Indicate all one-way down or reversible escalators are provided with a variable frequency regenerative drive C405.10 Controlled receptacles Identify all controlled and uncontrolled receptables on electrical plans in each space in which they are required; include receptacle configuration such as spacing between controlled and uncontrolled, duplex devices, etc; Indicate on plans whether the method of automatic control for each controlled receptable zone is by occupant sensor or programmable time -of -day control If "no" is selected for any question, provide explanation: End of Lighting, Motor & Transformer Permit Documents Checklist April 25, 2017 City of Tukwila Department of Community Development JOHN S MURDOCH PO BOX 3707 MC 46-88 SEATTLE, WA 98124 RE: Correction Letter # 1 DEVELOPMENT Permit Application Number D17-0083 BOEING #2-81.2 - 8123 EAST MARGINAL WAY S Dear JOHN S MURDOCH, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: KC ELLIS at (206)-431-3677 if you have questions regarding these comments. Provide sheet 2A283R and sheet 2A283. Also include a framing detail for the support of the operable wall partitions. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. . In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 433-7165. Sincerely, ( Pfi Rochelle Ripley Permit Technician File No. D17-0083 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 J °'ERMIT COORD COPY d PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0083 DATE: 05/03/17 PROJECT NAME: BOEING #2-81.2 SITE ADDRESS: 8123 E MARGINAL WAY S Original Plan Submittal X Response to Correction Letter # 1 Revision # before Permit Issued Revision # l after Permit Issued DEPARTMENTS: wilding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/04/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) Notation: (.I6..f. _� 5 DUE DATE: 06/01/17 Approved with Conditions Denied (ie: Zoning Issues) REVIEWER'S INITIALS: DATE: 'Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 PLANPli d 1/RCaTTING SLIF PERMIT NUMBER: D17-0083 DATE: 04/10/17 PROJECT NAME: BOEING #2-81.2 SITE ADDRESS: 7755 EAST MARGINAL WAY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: VE Cov 1- Lk -Q-17 Building Division Pe. q4 ) u ltc orks PI -M Ka 44111 Fire Prevention Structural L'J N`A- -p-13- t Planning Division Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) REVIEWER'S INITIALS: DATE: 04/11/17 Structural Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/09/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: 1Pernut Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ►':/ Fire 0 Ping 0 PW 0 Staff Initials: 12/18/2013 Date: q9) )1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Plan Check/Permit Number: D17-0083 ❑ Response to Incomplete Letter # ® Response to Correction Letter # _1_ ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner ❑ Deferred Submittal # Project Name: BOEING #2-81.2 Project Address: 8123 E MARGINAL WAY S Contact Person: 1/061V MANCH Phone Number: Summary of Revision: 1111)-6z/Li Sheet Number(s): "Cloud" or highlight all areas of revision includi g, ' t - of . gvisiop . Received at the City of Tukwila Permit Center by: 14 Entered in TRAKiT C:\Users\Rachelle-R\Desktop\Revision Submittal Form - 0160305.doc Revised: August 2015 BOEING COMPANY, THE 0 Washington State Department of Labor & Industries 0 Home rspaiiol Contact Safety & Health Claims & Insurance Search L&I Page 1 of 8 A -Z index Help My Lw Workplace Rights Trades & Licensing BOEING COMPANY, THE Owner or tradesperson LOHR, MICHAEL Principals LOHR, MICHAEL, SECRETARY MCNERNEY, W (JAMES), PRESIDENT (End: 01/13/2017) WOLTER, CHRISTOPHER, TREASURER (End: 01/16/2015) READ, PAUL, SECRETARY (End: 02/07/2013) SHRONTZ, F A, SECRETARY (End: 02/07/2013) GIVAN, B E, SECRETARY (End: 02/07/2013) KING, C G, SECRETARY (End: 02/07/2013) BEIGHLE, D P, TREASURER (End: 02/07/2013) COLLINS, T J, TREASURER (End: 02/07/2013) BUDINICH, T M, TREASURER (End: 02/07/2013) WOODARD, R B, TREASURER (End: 02/07/2013) CRUZE, D D, TREASURER (End: 02/07/2013) CONDIT, P M, TREASURER (End: 02/07/2013) WA UBI No. 178 005 030 100 N RIVERSIDE M/C 5003-4027 CHICAGO, IL 60606-1596 312-544-2535 Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. BOEINC*294ML Effective — expiration 07/13/1971— 01/18/2019 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 5/15/2017 BOEING COMPANY, THE Bond FEDERAL INS CO Bond account no. 81312466 $12,000.00 Received by L&I Effective date 01/14/2002 01/01/2002 Expiration date Until Canceled Insurance ..... ....................... Ace American Insurance Company Policy no. HDOG27854990 $1,000,000.00 Received by L&I Effective date 10/05/2016 10/01/2016 Expiration date 10/01/2017 Insurance history Savings ...................... No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No Ltd tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by, other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&i Account ID 700,216-00 Doing business as BOEING COMPANY THE Estimated workers reported N/A L&I account representative (360)902-4817 Track this contractor Self Insured. This business is certified to cover its own workers' comp costs. No premiums due. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 03/14/2017 Inspection no. 317943931 Location 3003 W Casino Rd Everett, WA 98203 Inspection results date 10/13/2016 Inspection no. 317940860 Location 7755,E. Marginal Way Seattle, WA 98108 Violations No violations Page 2 of 8 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=178005030&LIC=BOEINC*294ML&SAW= 5/15/2017 SYM THE COMPANY B UILDING 2-81 DENSITY IMPROVEMENTS 7775 E MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98'108 B UILDING 2-81 PROJECT # 4833402 LOCAT 0\ \ RFC3 O\ REVISION BY APPROVED DATE SYM v C T VA DUWAMISH WATERWAY 2-41 2-40 2-44 2-49 2-51 12-64 2-65 2-63 u Ii I 2-45 GATE B-18 SITE ACCESS 2-55 0. • I I 2 l I 2-66 2-5 a 0 3 2-81 r-12-6s�� 1 2-80 2-110 0 0 PROJECT SITE SCALE: NONE 2-84 2-117 2-116 • a -u \` 2-109 0 SEPARATE PERMIT REQUIRED FOR: 1l echanicEJ latticed P}umbtng as Piping City of Tukwila BUILDING DIVISION REVISION BY APPROVED DATE ORIG CDC RELOCATION - WIRE SHOP RELOCATION J#19670 DLR GROUP ECA 11.11.13 RECORD DRAWING J#19670 DLR GROUP ECA 04.07.14 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 CODES AND PERMITS PERMITS REQUIRED & FOR REVIEW: BUILDING PLUMBING MECHANICAL* ELECTRICAL FIRE PROTECTION ❑ GRADING ❑ LANDSCAPE ❑ DEMOLITION ❑ CIVIL (l STRUCTURAL *TO BE REVIEWED UNDER SEPARATE PERMIT WASHINGTON STATE NON—RESIDENTIAL ENERGY CODE COMPLIANCE OPTION PRESCRIPTIVE e LPA ❑ ANALYSIS ❑ N/A SPECIAL INSPECTIONS REQUIRED: ❑ WELD ❑ CONCRETE ❑ REBAR ❑ ANCHOR BOLTS. ❑ STRUCTURAL BOLTING ❑ STRUCTURAL OBSERVATION ❑ OTHER CALCULATIONS TYPE: ATTACHED (YES) (NO) TAX PARCEL NUMBER: 3324049002 LFGAL D1 -SCR DT 0 APN: 000160-0020 A TRACT OF LAND BETWEEN THE DUWAMISH WATERWAY AS ESTABLISHED BY COMMERCIAL WATERWAY DISTRICT #1 OF KING COUNTY, WASHINGTON AND EAST MARGINAL WAY IN SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M., AND IN THE JOHN BUCKLEY DONATION CLAIM NO. 42; SAID TRACT ALSO BEING THE SOUTHERLY PORTION OF A LARGER TRACT COMMONLY CALLED THE BOEING COMPANY'S PLANT NUMBER TWO SITE, DESCRIBED AS FOLLOWS: BEGINNING AT THE SECTION CORNER COMMON TO SECTIONS 28, 29, 32, AND 33; THENCE SOUTH 88°08'07" EAST ALONG THE NORTH LINE OF SAID SECTION 33, A DISTANCE OF 982.00 FEET TO AN INTERSECTION WITH THE SOUTHWESTERLY MARGIN OF EAST MARGINAL WAY;. THENCE SOUTH 47°51'53" EAST ALONG SOUTHWESTERLY MARGIN 684.62 FEET TO THE TRUE POINT OF BEGINNING OF THE TRACT HEREIN DESCRIBED; THENCE SOUTH 42'25'24" WEST 1215.02 FEET MORE OR LESS TO A POINT ON THE NORTHEASTERLY MARGIN OF SAID DUWAMISH WATERWAY, SAID POINT BEING ON A CURVE FROM WHENCE THE CENTER BEARS SOUTH 42' 16'23" WEST 1969.12 FEET; THENCE SOUTH- EASTERLY ALONG SAID CURVE, A DISTANCE OF 397.99 FEET TO THE POINT OF INTERSECTION WITH A LINE LYING 825.00 FEET SOUTH, AS MEASURED AT RIGHT ANGLES, OF THE NORTH LINE OF THE JOHN BUCKLEY DONATION LAND CLAIM NO. 42. THENCE SOUTH 89'09'36" EAST ALONG SAID LINE, PARALLEL WITH THE NORTH LINE OF SAID DONATION LAND CLAIM NO. 42, A DISTANCE OF 1387.45 FEET TO THE WESTERLY MARGIN OF EAST MARGINAL WAY; THENCE NORTH 22'32'15" WEST 160.30 FEET, FOLLOWING SAID WESTERLY MARGIN TO THE POINT OF CURVATURE OF A CURVE HAVING A RADIUS 2828.00 FEET; THENCE NORTHWESTERLY ALONG SAID CURVE, A DISTANCE OF 1250.10 FEET TO THE POINT OF TANGENCY OF SAID CURVE; THENCE NORTH 47°51'53" WEST 76.82. FEET TO THE TRUE POINT OF BEGINNING: THIS TRACT CONTAINING AN AREA OF 2,897,955 SQUARE FEET, MORE OR LESS. P>rmit Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of nv a .. ted code or ordinance. Receipt of approved Fi l id t• r . 1 nd conditi r ns is acknowledged: By Date: City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees: REGISTERED AHITECT CHRIS ED D CARLSON STATE OF WASHINGTON tel ittb 2015 IBC SECTION 1008 MEANS OF EGRESS ILLUMINATION REQUIRED The means of egress serving a room or space shall bE illuminated at all times that the room or space is occupied: illumination level shall be not less than 1 footcandle at the walking surface. The power supply for means of egress illumination shal normally be provided by the premises' electrical supply. In the event of power supply failure in rooms and spaces thai require two or more means of egress, an emergency electrica system shall automatically illuminate all of the following areas: 1. Aisles, 2. Corridors, 3. Exit access stairways and ramps. In the event of power supply failure in buildings that require two or more means of egress, an emergency electrical system shall automatically illuminate all of the following areas: 1,. Interior exit access stairways and ramps. 2. Interior and exterior exit stairways & ramps, 3. Exit passageways, 4. Vestibules at level of discharge, 5. Exterior landings and areas used for exit discharge. DATE REVIEWED FOR CODE COMPLIANCE APPROVED MAY 10 2017 City Of TukWit a BUILDING Nvit31 • N DRAWN M.CARMIER CHECKED L.ROBERTS EN INEER DATE 04.07.17 04.07.17 CODE SUMMARY TYPE OF APPLICATION: NEW ❑ ALTERATION ❑ ADDITION ❑ TENANT IMPROVEMENT NARRATIVE: 42,915 SF OF TENANT IMPROVEMENT OF THE INTERIOR ONLY ON THE SECOND FLOOR OF THE 02-81 BUILDING. DEMOLITION WILL INCLUDE THE REMOVAL OF FLOOR/CEILING FINISH MATERIALS, NON—LOAD BEARING WALLS, PLUMBING FIXTURES AND PORTIONS OF THE HVAC, ELECTRICAL AND PLUMBING SYSTEMS. TENANT IMPROVEMENT WILL INCLUDE NEW WALLS, CEILING TILES, AND FLOOR COVERINGS. ELECTRICAL POWER, LIGHTING, MECHANICAL, COMMUNICATION AND DATA SYSTEMS AND PLUMBING TO SUPPORT THE NEW LAYOUT. CODES: 2015 INTERNATIONAL BUILDING CODE (WAC 51-50) 2015 INTERNATIONAL FIRE CODE (WAC 51-54) 2015. INTERNATIONAL MECHANICAL CODE (WAC 51-52) 2015 UNIFORM PLUMBING CODE (WAC. 51-56 AND WAC 51-57) 2015 WASHINGTON STATE ENERGY CODE (WAC 51-11) 2009 ICC/ANSI A117.1 CURRENT CITY OF TUKWILA ZONING ORDINANCES /1 ORIGINAL CODE: OWNER: THE BOEING COMPANY CONTRACTOR & STATE NUMBER: THE BOEING COMPANY / BOEING*294ML EXP. 1/18/2015 BOEING PROJECT MANAGER: STACEY PARSON 206-304-0027 PROJECT DESIGN ARCHITECT / ENGINEER: LISA ROBERTS, BUFFALO DESIGN 206-467-6306 BOEING CONTACT: FAX NUMBER: E-MAIL:. JOHN.S.MURDOCHOBOEING.COM JOHN MURDOCH PHONE. 253-740-0214 ZONING: __._.:._._.__CITY OF TUKWILA _.........._..._._.. OCCUPANCY GROUP: B OFFICE CONSTRUCTION TYPE: _.II -B ALLOWABLE AREA INCREASE. - OCCUPANT LOAD: (ALLOWABLE) SEE A3 FOR FLOOR AREA: 62,828 SF/. FLOOR OCCUPANT LOAD: (ACTUAL) PROJECT__CODE_INFO (PER SECTION 502 DEFINITION OF BUILDING AREA) .00C.=- — BLDG GROSS x25.656_._._._....._ ...........: SQ FT BASEMENT SQ FT FIRST FLOOR 62,828 SQ FT SECOND FLOOR 62,828 _...._._._..._.. SQ FT THIRD FLOOR , _SQ FT FOURTH FLOOf SQ FT FIFTH FLOOR SQ FT SIXTH FLOOR SQ FT PENTHOUSE SQ FT PROJECT AREA OFFICES STORAGE ASSEMBLY • OCC. CANOPY_.. OTHER _..._._._..-.---.._._._ _--OCC .= PENTHOUSE OCC = BUILDING HEIGHT: (ACTUAL) 41'-2" STORIES: 42, 915 SQ FT 2.:._....... MEZZANINE ? ® (YES) ❑ (Nd) SQ FT 1,265 SF FIRE PROTECTION: SPRINKLERED THROUGHOUT ® (YES) ❑ (NO) NFPA 13 AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITH QUICK RESPONSE HEADS. SEPARATION 2 HOUR AT EXISTING BUILDINGS AND GRID 17 (Q2-80/02-81) EXTERIOR WALL (NON-BEARING) EXTERIOR WALL_ (BEARING) ____.._..:..._.. INTERIOR WALL (NON-BEARING)._...... INTERIOR . WALL (BEARING) DEMOUNTABLE PARTITIONS STRUCTURAL FRAME ...._:___ .---.___._._....__-.-----_--.____-... FLOOR/CEILINGS_____ _.......... ROOF CONSTRUCTION SEISMIC CATEGORY: ZONE D DESIGN LOADS: (CHAPTER 23) ROOF: LIVE (SNOW) ---._.... FLOOR: OFFICE MECH/STOR— STAIRS._ PENTHOUSE ._______...__..._....... ...._ CONCENTRATED: WIND. EXPOSIIRE HOUR RATING HOUR RATING HOUR RATING HOUR RATING HOUR RATING HOUR RATING HOUR RATING HOUR RATING NOTE: FOR. ADDITIONAL COOL INFORMATION SEE COMPOSITE CODE PLAN SERIES A3 PI1-Oof/ 3 SUBTITLE RECEIVED CITY OF TUKWILA APR 10 2017 COVER SHEET PERMIT CENTER CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 PLANT2, WA W4833402 PERMIT SUBMITTAL 04.07.17 CURRENT REVISION W4833402 SHEET SYMBOL DATE 04.07.17 GO JOB NO. 19760 COMP NO. DWG NO. 2 -81 -GO u u u C C. C • C C L LEGE D/SYV 3OLS MATERIAL SYVBOLS A]BREVATIO\S GE\RAL OTES Att\A axa SECTION/DETAIL DESIGNATION BUILDING, WALL SECTIONS AND DETAIL REFERENCES #X SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM INTERIOR ELEVATION REFERENCE SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM IREFERENCE TO DETAIL/ENLARGED PLAN l 1 DETAIL DESIGNATION SHEET NUMBER WHERE DETAILED (IF SAME AS SHEET REFERENCED FROM) SECTION/DETAIL DESIGNATION XXXXX XXXXX- SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM NORTH ARROW ELEVATION DATUM XXXXXX XXXX SYM FT (CPT -1) OR SPOT ELEVATION CEILING HEIGHT A.F.F. ROOM NAME ROOM NUMBER DOOR NUMBER GRID/GRID BUBBLE AND CENTERLINE VCT CPT FEo- FEC .1114 jatt r a,tt,tt, o� 0 1-0 ITEMS TO BE REMOVED CONSTRUCTION "FLAG" NOTE FOR SPECIFIC CONSTRUCTION DIRECTIVE GENERAL "BOAT" NOTE FOR SPECIFIC OR EXISTING HISTORICAL INFORMATION. WINDOW FRAME TYPE PARTITION/WALL TYPE END WALL GUARD CORNER GUARD FINISH DESIGNATION REVISION CLOUD WITH REVISION LETTER "BEAK" FLOOR MAT'L TRANSITION FIRE EXTINGUISHER FIRE EXTINGUISHER & CABINET SUPPLY AIR DIFFUSER RETURN AIR GRILLE FLOURESCENT LIGHT FIXTURE (PENDANT MOUNTED) FLOURESCENT LIGHT FIXTURE (PENDANT MOUNTED) FLOURESCENT LIGHT FIXTURE ON EMERGENCY NIGHT LIGHT (NL) CIRCUIT RECESSED OR PENDANT LIGHTING FIXTURE RECESSED OR PENDANT LIGHTING FIXTURE FLOURESCENT LIGHT FIXTURE ON EMERGENCY. NIGHT LIGHT (NL) CIRCUIT WALL SCONCE 1 WALL SCONCE 2 EXIT SIGN (CEILING UNIT) EXIT SIGN (WALL MOUNT) REVISION BY APPROVED DATE SYM REVISION MicM1S81c8141Z1 WRMWSM J J J EARTH, DIRT, COMPACTED STONE, GRAVEL, POROUS FILL BRICK, COMMON CERAMIC TILE CONCRETE INSULATION: BATT, LOOSE FILL, BLANKET EARTH, DIRT, UNDISTURBED INSULATION: RIGID ALUMINUM BRASS, BRONZE, COPPER METAL, STEEL, IRON PLASTER: SAND, CEMENT, GROUT PLASTER: GYPSUM WALL BOARD WOOD: FINISH WOOD: ROUGH CONTINUOUS WOOD: INTERRUPTED BLOCKING // A PLYWOOD: SMALL SCALE PLYWOOD: LARGE SCALE WALL TYPE: CONCRETE MASONRY (CMU) WALL TYPE: STEEL STUD WALL TYPE: WOOD STUD WALL TYPE: EXISTING WALL TYPE: REMOVAL WALL TYPE: PARTITION (7'-0" HIGH) WALL TYPE: GLASS BY APPROVED DATE ORIG CDC RELOCATION - RELOCATE TO 3-801 J#19670 DLR GROUP ECA 12.6.13 RECORD DRAWING J#19670 DLR GROUP ECA 04.07.14 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 Q� BOE/NG 6'- AB ACP ACT ADJ AFF AGG AL ALT ALUM ANCH APA APPD APPROX ASTM BTWN BLDG BLKG BO BOT C CB CC CEM CF CFCI CG. CJ CL CLG CLR COL COMP CONC CONN CONST CONT CONTR CT CTSK CY 0, DIA DBL DEMOL DEP DIA DIAG DIM DL DN DS DWG EA EB EF EJ EL ELEV EQ EW EX EXP EXT FAS FE FEC FF FF FF FGR FH FIN FND FOC FOF FOIC FO FRO FT FTG FUT FV GA CRFG GALV GC GI GR GT GWB HDNR HDWD HDWR HG HM HORZ HS HT IBC ID ID IF AND AT ANCHOR BOLT ACOUSTICAL CEILING PANEL ACOUSTICAL CEILING TILE ADJACENT ABOVE FINISHED FLOOR AGGREGATE ALUMINUM ALTERNATE ALUMINUM ANCHOR, ANCHORAGE AMERICAN PLYWOOD ASSOC. APPROVED APPROXIMATE AMERICAN SOCIETY OF TESTING MATERIALS BETWEEN BUILDING BLOCKING BOTTOM OF BOTTOM CHANNEL CATCH BASIN CENTER TO CENTER CEMENT CUBIC FEET CONTRACTOR FURNISHED CONTRACTOR CORNER GUARD CONTROL JOINT CENTER LINE CEILING CLEAR(ANCE) COLUMN COMPRESS(ED) (ION) CONCRETE CONNECTION CONSTRUCTION CONTINUOUS, CONTINUE CONTRACT(OR) CERAMIC TILE COUNTERSUNK CUBIC YARD(S) DIAMETER DOUBLE DEMOLISH, DEMOLITION DEPRESSED DIAMETER DIAGONAL DIMENSION DEAD LOAD DOWN DOWNSPOUT DRAWING EAST (COORDINATE) EACH EXPANSION BOLT EACH FACE EXPANSION JOINT ELEVATION ELEVATION EQUAL EACH WAY EXISTING EXPOSED EXTERIOR FASTEN(ER) FIRE EXTINGUISHER FIRE EXTINGUISHER CABINET FINISHED CEILING FACTORY FINISH FINISHED FLOOR FINISH GRADE FIRE HYDRANT FINISH(ED) FOUNDATION FACE OF CONCRETE FACE OF FINISH FURNISHED BY OWNER/ INSTALLED BY CONTRACTOR FINISHED OPENING FOR REFERENCE ONLY FOOT FOOTING FUTURE FIELD VERIFY GAGE GLASS FIBER REINFORCED GYPSUM GALVANIZED GENERAL CONTRACTOR GALVANIZED IRON GRADE GROUT GYPSUM WALL BOARD HARDENER HARDWOOD HARDWARE HIGH GRADE HOLLOW METAL HORIZONTAL HIGH STRENGTH HEIGHT INTERNATIONAL BLDG. CODE INSIDE DIAMETER INSIDE DIMENSION INSIDE FACE 39 3 REGISTERED ITECT CHRIS EDWARD CARLSON STATE OF WASHINGTON INSTALLED IN INCL JT KO LB LEN LF LL LWR MATL MAX MB MBR MTL MFR MIN MISC MO MT MTL NF NIC NO. NOM NTS OA 0/C OD OF OFCI OFOI OPG OPP PAR PCC PCF PERF PERIM PG PL PLAM PLYWD PNL PREST PRF PSF PSI PT PVC R R RB REF REINF REQ REV RH RO S SECT SF SHT SIM SQ SS SST ST STD STL STR SYM SYS T&B T&G TEMP THK TOC TOC TOL TOS TS TYP UBC UL UNO UPR VB VC VERT VIF W W W WC WD W/ W/O WWF INCH INCLUDED(D) (ING) JOINT KIP(S) KNOCK OUT LENGTH LAG BOLT LENGTH LINEAL FEET LIVE LOAD LOWER MATERIAL MAXIMUM MACHINE BOLT MEMBER METAL MANUFACTURE(R) MINIMUM MISCELLANEOUS MASONRY OPENING MOUNT(ED) (ING) METAL NORTH (COORDINATE) NEAR FACE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE OVERALL ON CENTER OUTSIDE DIAMETER OUTSIDE FACE OWNER FURNISHED CONTRACTOR INSTALLED OWNER FURNISHED OWNER INSTALLED OPENING OPPOSITE, OPPOSITE HAND PARALLEL PRECAST CONCRETE POUNDS PER CUBIC FOOT PERFORATE(D) PERIMETER PATTERN GLASS PLATE PLASTIC LAMINATE PLYWOOD PANEL PRESTRESS(ED) PREFORMED POUNDS PER SQUARE FOOT POUNDS PER SQUARE INCH POINT, PAINT POLYVINYL CHLORIDE RADIUS (CURVATURE) RISER RESILIENT BASE REFERENCE, REFER TO REINFORCE(D) (ING) REQUIRE(D) (ING) REVERSE, REVISION(S), REVISED RIGHT HAND ROUGH OPENING SOUTH (COORDINATE) SECTION SQUARE FEET SHEET SIMILAR SQUARE SOLID SURFACING STAINLESS STEEL STRUCTURAL TEE STANDARD STEEL STRUCTURAL SYMMETRY,SYM METRICAL SYSTEM TOP AND BOTTOM TONGUE AND GROOVE TEMPORARY THICK(NESS) TOP OF CURB TOP OF CONCRETE TOLERANCE TOP OF STEEL STRUCTURAL TUBE TYPICAL UNIFORM BUILDING CODE UNDERWRITERS' LABEL UNLESS NOTED OTHERWISE UPPER VAPOR BARRIER VINYL COMP. TILE VERTICAL VERIFY IN FIELD. WEST (COORDINATE) WIDE FLANGE WIDTH, WIDE WATER 'CLOSET WOOD WITH WITHOUT WELDED WIRE FABRIC NOTE: REFER TO THE COLOR AND MATERIAL SCHEDULE FOR ADDITIONAL FINISH AND DESIGNATIONS/ABBREVIATIONS DRAWN DATE M.CARMIER 03.17.17 CHECKED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED REVIEWED FOR CODE GOMPLIANCE AP PROVED MAY102017 City Of Tukwila BUILDING DIVISION SUBTITLE 1. OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY COMMENCING CONSTRUCTION. 2. VERIFY ALL EXISTING CONDITIONS AND NOTIFY THE BOEING PROJECT SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. OF TUKWILA PRIOR TO CONSTRUCTION MANAGER 3. THE SCOPE OF WORK INCLUDES ALL WORK WITHIN THE CURRENT REVISION CLOUD(S ON EACH SHEET. IF THERE IS NO CLOUD ON A SHEET THE ENTIRE SHEET IS IN THE SCOPE OF WORK. INFORMATION OR WORK (WHETHER CLOUDED OR NOT) REFERRED TO FROM WITHIN A CLOUD IS INCLUDED IN THE SCOPE OF WORK (I.E. — A SECTION OR DETAIL SYMBOL THAT LIES WITHIN A CLOUD ON A PLAN VIEW SHEET IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL SECTION OR DETAIL DRAWN ON THE DETAIL SHEET IS NOT CLOUDED.) 4. KEEP ALL AREAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT IN AREA DESIGNATED BY THE BOEING PROJECT CONSTRUCTION MANAGER. 5. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY. THE CONTRACTOR SHALL ADVISE BOEING, SUMMARIZE THE SITUATION AND PROVIDE RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR TO SUBMITTING ANY REQUESTS FOR INFORMATION (RFIs). 6. CONFORM ALL WORK TO APPLICABLE CODES, REGULATIONS AND INDUSTRY STANDARDS. 7. COMPLY WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND SECURITY REGULATIONS. 8. PROVIDE, AS IF DRAWN IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS. DIMENSIONS ON DRAWINGS ARE TAKEN TO THE FACE•OF MASONRY AND/OR CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED. 10. DOOR OPENINGS ARE 6" FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS DIMENSIONED OTHERWISE. 11. PARTITIONS SHALL RUN FULL HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED OTHERWISE. 12. PLANS WHICH APPEAR AS "BACKGROUNDS" ON CIVIL, STRUCTURAL, PLUMBING, HVAC, ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLAN CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER THAN THAT PERTAINING TO THE TITLE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. 13. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH—IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR BY OTHERS FOR THIS PROJECT. 14. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT. CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN THE CONSTRUCTION NOTES. 15. CONTRACTOR SHALL COORDINATE WITH THE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING AREAS WHERE CONTRACTOR MAY STORE SALVAGED MATERIALS TO BE REUSED IN LATER PARTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ARE TO BE LOCATED. 16. SYMBOLS SHOWN ON MATERIALS LIST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL CALLOUTS. 17. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH AND REPAIR THE EXISTING TO MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK LINES SUCH AS CORNERS, CEILING LINES, TOP OF BASE, CHANGE IN MATERIAL OR SIMILAR. 18. ALL RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN REQUIRED FIRE RATING OF THE PARTITION. 19. ARCHITECTURAL REFLECTED CEILING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL AND. ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING PLANS FOR LOCATIONS OF ITEMS IN THE CEILING; SEE DISCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE. MECHANICAL AND ELECTRICAL COMPONENTS INDICATED ON ARCHITECTURAL •REFLECTED CEILING PLANS. 20. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS. 21. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND THE LIMITS OF THE ARCHITECTURAL DRAWINGS. 22. AT METAL STUD PARTITIONS, STUDS ARE TO. EXTEND FROM FLOOR TO FLOOR U.N.O.. WHERE THEY CANNOT DO SO, DUE TO INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE ABOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PARTITION; SUBMIT EQUIVALENT SUPPORT METHOD TO ARCHITECT FOR REVIEW. ALL FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE, U.N.O. 23. PROVIDE ACCESS DOORS AS INDICATED OR AS NECESSARY AND VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER LINKAGES, CONCEALED JUNCTION BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES OF EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR TO INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT. 24. THECONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL SAFETY CODES, REGUALTIONS AND BOEING REQUIREMENTS. 25. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON TO DETERMINE/DESIGN THE MODIFIED FIRE SPRINKLER SYSTEM LAYOUT WITHIN THE AREA OF WORK.' SAID ENGINEER SHALL STAMP, SEAL AND CERTIFY THAT HIS/HER DESIGN IS IN COMPLIANCE W/ALL APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE ALL NECESSARY MODIFICATIONS AS A RESULT OF SAID ENGINEER'S DESIGN. 26. THE CONTRACTOR SHALL INSURE THAT THE ELEVATOR CAR, EQUIPMENT ROOM, EQUIPMENT LAYOUT AND HYDRAULIC/ELECTRICAL ROUTING FULLY MEETS STATE OF WASHINGTON CODES AND COMPLIANCE. FULLY COORDINATE WITH ARCHITECT PRIOR .TO FABRICATION AND INSTALLATION. 27. AT LOCATIONS WHERE STRUCTURE, . PIPING, DUCTWORK, CABLETRAY, OR CONDUIT PENETRATES WALLS AND ARE EXPOSED TO VIEW, CONTRACTOR SHALL COPE AS CLOSELY AS POSSIBLE TO THE MEMBER AND INSTALL CONTINUOUS CAULKING AROUND MEMBER AND PAINT OR PROVIDE ESCUTCHEONS MATCHING WALL COLOR AT PENETRATIONS. 28. FOR CONSISTENCY ALL CONSTRUCTION NOTES ("FLAG NOTES") FOR EACH GROUP: PLAN AND RCP'S, ARE SHOWN IN THEIR ENTIRETY. ALL CONSTRUCTION NOTES MAY NOT BE REFERENCED ON EVERY SHEET. 29. FRAME TYPES ARE TYPICALLY DRAWN LOOKING FROM THE OUTSIDE OR CORRIDOR SIDE UNO. RECEIVED CITY OF TUKWILA \ W4833402 APR 10 2017 PERMIT CENTER PERMIT SUBMITTA 04.07.17 KEY SHEET CURRENT- REVISION W4833402 SYMBOL DATE 04.07.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS BUILDING 3-801 ARCHITECTURAL MASTER NO.BOEING FIELD, WA SHEET G1 JOB NO. 19760 COMP NO. DWG NO. 3-801—G1 INDEX OF DRAWINGS INCLUDED IN SET DRAWING NO. SHEET NO. DRAWING TITLE GENERAL 2-81—GO • 2-81—G1 Co 2-81—G2 COVERSHEET KEY. SHEET DRAWING INDEX 04.07.17 04.07.17 04.07.17 CIVIL LANDSCAPE SYM REVISION BY APPROVED DATE SYM REVISION INCLUDED INSET DRAWING NO. SHEET NO. DRAWING TITLE REV DATE ARCHITECTURAL • 2-81-2A3 • 2-81-2A3a • 2-81-2A1 OR • 2-81-2A11R • 2-81-2Al2R • 2-81-2A13R • 2-81-2A80R • 2-81-2A81R • 2-81-2A82R 2A3 2A3a 2A1 OR 2A11R 2Al2R 2A13R 2A280R 2A281 R 2A282R LIFE SAFETY PLAN — SECOND FLOOR ORIG 04.07.17 COMPOSITE FURNITURE PLAN — SECOND FLOOR PARTIAL FLOOR PLAN DEMOLITION PARTIAL FLOOR PLAN DEMOLITION PARTIAL FLOOR PLAN DEMOLITION PARTIAL FLOOR PLAN DEMOLITION PARTIAL SECOND FLOOR RCP DEMOLITION PLAN ORIG 04.07.17 A 04.07.17 A 04.07.17 A 04.07.17 A 04.07.17 A 04.07.17 PARTIAL SECOND FLOOR RCP DEMOLITION PLAN PARTIAL SECOND FLOOR RCP DEMOLITION PLAN A 04.07.17 A 04.07.17 2-81-2A83R '44 2-81-2A10 2A283R ` , 2A10 PARTIAL SECOND FLOOR RCP DEMOLITION PLAN A 04.07.17 PARTIAL SECOND FLOOR PLAN A 04.07.17 2-81-2A11 PARTIAL SECOND FLOOR PLAN 04.07.17 2-81-2Al2. 2-81-2A13 • 2-81-2A280 2Al2 2A13 2A280 PARTIAL SECOND FLOOR PLAN 04.07.17 PARTIAL SECOND FLOOR PLAN 04.07.17 PARTIAL SECOND FLOOR REFLECTED CEILING PLAN A 04.07.17 INCLUDED IN SET DRAWING NO. SHEET NO. DRAWING TITLE ELECTRICAL (CON.) 208Y/120V POWER PLAN 2-81-2E61 208Y/120V POWER 208Y/120V POWER PLAN 2-81-2E63 208Y/120V POWER PLAN 2-81-2E360 2E360 TELECOMMUNICATION PLAN 2-81-2E361 2E361 TELECOMMUNICATION PLAN 2-81-2E362 2-81-2E363 2E362 TELECOMMUNICATION PLAN 2E363 TELECOMMUNICATION PLAN STRUCTURAL 2-81-2A281 2-81-2A282 2A281 PARTIAL SECOND FLOOR REFLECTED CEILING PLAN A 04.07.17 2A282 PARTIAL SECOND FLOOR REFLECTED CEILING PLAN A 04.07.17 2-81-2A283 •1 2A283�, PARTIAL SECOND FLOOR REFLECTED CEILING PLAN 04.07.17 O 2-81-2A1 OF O 2-81-2A11F O 2-81-2Al2F O 2-81-2A13F • 2-81—A362 2A1 OF 2A11F 2Al2F 2A13F A362 PARTIAL SECOND FLOOR PLAN — FURNITURE PLAN 04.07.17 PARTIAL SECOND FLOOR PLAN — FURNITURE PLAN A 04.07.17 PARTIAL SECOND FLOOR PLAN — FURNITURE PLAN A 04.07.17 PARTIAL SECOND FLOOR PLAN — FURNITURE PLAN A 04.07.17 FINISH AND DOOR SCHEDULE ORIG 04.07.17 2-81-A4XX • 2-81—A4XXa 2-81-A4XXb 2-81—A5XX A4XX A4XXa A4XXb A5XX INTERIOR ELEVATIONS— 2ND FLOOR ORIG 04.07.17 INTERIOR ELEVATIONS— 2ND FLOOR ORIG 04.07.17 INTERIOR ELEVATIONS— 2ND FLOOR ORIG 04.07.17 MISCELLANEOUS SECTIONS AND DETAILS ORIG 04.07.17 MECHANICAL O 2-81—MO O 2-81—M1A LEGEND EQUIPMENT SCHEDULE 04.07.17 04.07.17 O 2-81—M1B O 2-81-2M1OR M1B 2M1OR EQUIPMENT SCHEDULE 04.07.17 DUCTWORK PLAN DEMOLITION 04.07.17 O 2-81-2M11R 2M11R DUCTWORK PLAN DEMOLITION 04.07.17 O 2-81-2M12R O 2-81-2M13R O 2-81-2M10 2M12R 2M13R 2M10 DUCTWORK PLAN DEMOLITION E 04.07.17 DUCTWORK PLAN DEMOLITION C 04.07.17 DUCTWORK PLAN C 04.07.17 O 2-81-2M11 DUCTWORK PLAN 04.07.17 O 2-81-2M12 O 2-81-2M13 O 2-81-2M260 2M12 2M13 2M260 DUCTWORK PLAN E 04.07.17 DUCTWORK PLAN C 04.07.17 FIRE PROTECTION PLAN 04.07.17 O 2-81-2M261 O 2-81-2M262 O 2-81-2M263 O 2-81—RFM3 O 2-81—M310 O 2-81-M312 O 2-81—M320 O 2-81—M330 O 2-81—M505 O 2-81—M506 O 2-81—M508 O 2-81—M530 2M261 2M262 2M263 RFM3 M310 M312 M320 M330 M505 M506 M508 M530 FIRE PROTECTION PLAN A 04.07.17 FIRE PROTECTION PLAN A 04.07.17 FIRE PROTECTION PLAN A 04.07.17 DUCTWORK AND HVAC PIPING C 04.07.17 HVAC CONTROL SEQUENCES C 04.07.17 HVAC FLOW DIAGRAM A 04.07.17 SECOND FLOOR HEATING WATER PIPING DIAGRAM A 04.07.17 TERMINAL EQUIPMENT P&ID B 04.07.17 HVAC DETAILS A 04.07.17 HVAC DETAILS A 04.07.17 HVAC DETAILS A 04.07.17 STANDARD CONNECTION DETAILS A 04.07.17 ELECTRICAL O 2-81-2E1OR 2E1OR LIGHTING PLAN DEMOLITION 04.07.17 O 2-81-2E11R 2E11R LIGHTING PLAN DEMOLITION 04.07.17 • 2-81-2E12R •. 2-81-2E13R • 2-81-2E15R O 2-81-2E6OR O 2-81-2E61R 2E12R 2E13R 2E15R 2E6OR 2E61R LIGHTING PLAN DEMOLITION LIGHTING PLAN DEMOLITION LIGHTING PLAN DEMOLITION B 04.07.17 B 04.07.17 A 04.07.17 208Y/120V POWER PLAN DEMOLITION 208Y/120V POWER DEMOLITION O 2-81-2E63R O 2-81-2E360R 2E63R 2E360R 208Y/120V POWER DEMOLITION TELECOMMUNICATION PLAN DEMOLITION O 2-81-2E361R 2-81-2E10 2E361R 2E10 TELECOMMUNICATION PLAN DEMOLITION LIGHTING PLAN 04.07.17 O 2-81-2E11 LIGHTING PLAN 04.07.17 O 2-81-2E12 O 2-81-2E13 O 2-81-2E15 2E12 2E13 2E15 LIGHTING PLAN B 04.07.17 LIGHTING PLAN B 04.07.17 LIGHTING PLAN B 04.07.17 2-81—E500 E500 LIGHTING FIXTURE SCHEDULE 04.07.17 O 2-81—E500a E500a LIGHTING FIXTURE SCHEDULE 04.07.17 BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/JJB 11.12.99 DENSITY IMPROVEMENTS- 2ND FLOOR W4833402 BUFFALO 04.07.17 Q� BOE/NG° 973 •� 1 'RIS D ARD C LSON REGISTERED ARCHITECT STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED N C.RISKE DATE APPROVED BY DEPT. DATE CHECKED J.HILLIER ENGINEER C.RISKE SUBTITLE DRAWING INDEX ISSUE LEGEND NOT YET ISSUED 0 PREVIOUSLY ISSUED, 0 NOT IN THIS RELEASE IN THIS ISSUE NFC FRO ORIG A PREL NOT FOR CONSTRUCTION FOR REFERENCE ONLY ORIGINAL ISSUE FOR CONSTRUCTION OR FOR PERMIT DRAWING REVISION — SEE SPECIFIC DRAWING FOR NATURE OF REVISION PRELIMINARY REVIEWED FOR CODE COMPLIANCE APPROVED MAY 102017 City of Tukwila BUII DING RECEIVED CITY OF TUKWILA APR 10 2017 PERMIT CENTER W4833402 PERMIT SUBMITTAL 04.07.17 CURRENT REVISION W4833402 SYMBOL DATE 04.07.17 CHECKED J.HILLIER APPROVED J.HILLIER APPROVED M.PRITTIE 1.12.98 TITLE ARCHITECTURAL MASTER BUILDING 2-81 PLANT 2 SHEET G2 JOB NO. 972197-00 COMP NO. DWG NO. 2-81—G2 u C C Ij TIAL FLOC SCALE: 1/8" = (2) CD CD V) REVIEWED FOR CODE COMPLIANCE • APPROVED MAY 10 2017 City of Tukwila BUILDING LEGE \D 4 REMOVAL SHADED AREA NOT INCLUDED IN PROJECT SCOPE GE\ERAL DEv1OLITION \OTES • 1. NOTES ARE COMMON TO THE PROJECT; NOT ALL FLAG NOTES APPEAR ON EACH DEMOLITION PLAN. 2. QUANTITIES OF WORK, WHERE LISTED, ARE ESTIMATES ONLY.— GC TO VERIFY TOTAL AMOUNTS IN FIELD. 3. PROTECT AND MAINTAIN CONSTRUCTION NOT SCHEDULED FOR DEMOLITION. MAINTAIN ACCESS TO RESTROOMS AND MECHANICAL ROOMS SCHEDULED TO REMAIN. 4. PROTECT AND MAINTAIN FIRE PROTECTION SYSTEM: MAIN AND ALL HORIZONTAL AND VERTICAL PIPING DURING DEMOLITION. SEE— MECHANICAL. 5. WHERE ELECTRICAL FLOOR RECEPTACLES ARE CALLED OUT TO BE REMOVED ON POWER PLAN REMOVAL DRAWING. FILL PENETRATION WITH CEMENTITIOUS MATERIAL LEVEL WITH EXISTING SLAB. FrovrVe•bartr-trs te,fwee-K 4€1411)7"hlrvc-iY etc/F-IvilYe,f co/to! Roe.c'frtcl eAmli6ye=e- occ-1( cbreAs), ' DEV OLITIO\ \OTES REMOVE. CARPET + WALL BASE. FROM PROJECT AREA. REMOVE ALL CLOCKS AND WHITE BOARDS FROM PROJECT AREA AND RETURN TO PROJECT ADMINISTRATOR. REMOVE ALL SIGNAGE FROM PROJECT AREA. • A ''I \AAA A VW, REMOVAL W4833402 PERMIT SUBMITTAL 04.07.17 2-81 BUILDING KEY PLAN SCALE: NTS ECEIVED CI OF TUKVVILA APR 10 2017 PERMIT CENTER DATE 04.07.17 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 gii..._Am„Eriermr.ff® 3973 REGISTERED Ael ' CT Ri CHRIS EDWARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN B. FERGER DATE CHECKED J. HILLIER SUBTITLE PARTIAL SECOND FLOOR PLAN CURRENT REVISION W4833402 SYMBOL APPROVED BY DEPT. DATE ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS 2-81 3UILDI\G ARCHITECTURAL MASTER COL. A—F/1 3 PLANT 2 SHEET 2A1 OR JOB NO. 972197-00 COMP NO. DWG NO. 2-81-2A1OR 23E4 REPRODUCTION ROOM 21 F2 22G2 PARTIAL FL00PLA\ SCALE: 1/8" = 1'-0' 21 H2 VISIBILTY ROOM 22J2 21K4 171 REVIEWED FOR CODE COMPLIANCE APPROVED MAY 107011 City of Tukwila BUILDING DIS • LEGEND 4 REMOVAL SHADED AREA NOT INCLUDED IN PROJECT SCOPE GE\ERAL DEMOLITION NOTES 1. NOTES ARE COMMON TO THE PROJECT; NOT ALL FLAG NOTES APPEAR ON EACH DEMOLITION PLAN. QUANTITIES OF WORK, WHERE LISTED, ARE ESTIMATES ONLY - GC TO VERIFY TOTAL AMOUNTS IN FIELD. 3. PROTECT AND MAINTAIN CONSTRUCTION NOT SCHEDULED FOR DEMOLITION. MAINTAIN ACCESS TO RESTROOMS AND MECHANICAL ROOMS SCHEDULED TO REMAIN. PROTECT AND MAINTAIN FIRE PROTECTION SYSTEM: MAIN AND ALL HORIZONTAL AND VERTICAL PIPING DURING DEMOLITION. SEE- MECHANICAL. 5. WHERE ELECTRICAL FLOOR RECEPTACLES ARE CALLED OUT TO BE REMOVED ON POWER PLAN REMOVAL DRAWING. FILL PENETRATION WITH CEMENTITIOUS MATERIAL LEVEL WITH EXISTING SLAB. JEVCLITIO\ \OTES REMOVE CARPET + WALL BASE FROM PROJECT AREA. REMOVE ALL CLOCKS AND WHITE BOARDS FROM PROJECT AREA AND RETURN TO PROJECT ADMINISTRATOR. REMOVE ALL SIGNAGE FROM PROJECT AREA. REMOVE DOOR AND FRAME. RELOCATE AS NOTED. i> CUT OPENING FOR NEW DOOR. REMOVE/ RELOCATE FEC. REMOVE GWB PARTITIONS. REMOVAL W4833402 PERMIT SUBMITTAL 04.07.17 2-81 BUILDING KEY PLAN SCALE: NTS ED CITY O ' UIKWILA APR 10 2017 PERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 3973 1 REGISTERED A‚'I TELT CHRIS ElCARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN B. FERGER DATE CHECKED J. HILLIER SUBTITLE PARTIAL SECOND FLOOR PLAN CURRENT REVISION W4833402 SYMBOL A DATE. 04.07.17 APPROVED BY DEPT. DATE ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY . IMPORVEMENTS 2-81 3UILD1\G ARCHITECTURAL MASTER COL. F -L/1-3 PLANT 2 SHEET 2AIIR JOB NO. 972197-00 COMP NO. DWG NO. 2-81-2A1OR � n /1') Inn _1 n.Gc....,. C 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" MATCHLINE SEE SHEET 2A1OR 0 0 STORAGE ROOM SLOPE 0 0 CONFERENCE ROOM CONFERENCE ROOM VENDING ROOM CANOPY ROOF BELOW SLOPE CONFERENCE ROOM CONCEILING PLAN— CALL OUT FOR CEILING GRID AND TILE TO BE REMOVED IN THIS ROOM. SLOPE CRICKET SLOPE 1/4" PER FOOT MIN. OPEN OFFICE REVIEWED FOR CODE COMPLIANCE PPROVED MAY 10 2017 City of Tukwila BUILDING DIVISION LEGE \ D 4 GENE REMOVAL SHADED AREA NOT INCLUDED IN PROJECT SCOPE SAL DEMOLITIO\ NOTES '1. NOTES ARE COMMON TO THE PROJECT; NOT ALL FLAG NOTES APPEAR ON EACH DEMOLITION PLAN. 2. QUANTITIES OF WORK, WHERE LISTED, ARE ESTIMATES ONLY — GC TO VERIFY TOTAL AMOUNTS IN FIELD. PROTECT AND MAINTAIN CONSTRUCTION NOT SCHEDULED FOR DEMOLITION. MAINTAIN ACCESS TO RESTROOMS AND MECHANICAL ROOMS SCHEDULED TO REMAIN. 4. PROTECT AND MAINTAIN FIRE PROTECTION SYSTEM: MAIN AND ALL HORIZONTAL AND VERTICAL PIPING DURING DEMOLITION. SEE- MECHANICAL. 5. WHERE ELECTRICAL FLOOR RECEPTACLES ARE CALLED OUT TO BE REMOVED ON POWER PLAN REMOVAL DRAWING. FILL PENETRATION WITH CEMENTITIOUS MATERIAL LEVEL WITH EXISTING SLAB. D EIV O LITI O\ OTES REMOVE CARPET + WALL BASE FROM PROJECT AREA. REMOVE ALL CLOCKS AND WHITE BOARDS FROM PROJECT AREA AND RETURN TO PROJECT ADMINISTRATOR. REMOVE ALL SIGNAGE FROM PROJECT AREA. REMOVE EXISTING OPERABLE PARTITION AND RELATED STRUCTURE. RCMOVC DOOR AND (RAMC RC CUT OPENING FOR NEW DOOR. REMOVE/ RELOCATE FEC. REMOVAL I 2A10 2A11 2A13 2A13 2Al2 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE PARTIAL PLA\ VIEW SCALE: 1/8" = 1'-0" RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 CDC RELOCATION - WIRE SHOP RELOCATION J#19670 DLR GROUP ECA 11.11.13 RECORD DRAWING J#19670 DLR GROUP ECA 04.01.14 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 W4833402. PERMIT SUBMITTAL ,. x,4.07.17 3973 Q� BOE/NG o'- 1;! ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN B. FERGER DATE CHECKED J. HILLIER SUBTITLE PARTIAL SECOND FLOOR PLAN 2-81 BUILDING KEY PLAN SCALE: NTS CURRENT REVISION W4833402 WED CITY OF TUKWILA APR 10 2017 PERMIT CENTER SYMBOL 3 DATE 04.07.17 ENGINEER C. RISKE CHRIS EDWARD CARLSON STATE OF WASHINGTON CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. A—F/3-8 PLANT 2, WA SHEET 2Al2R JOB NO. 19670 COMP NO. DWG NO. 2-81-2Al2R u CA kir,' II A. 7 171: MAA A SYM REVISION 22 30'-0" 30'-0" 30'-0" 30'-0" 1.4'-0" i ''','!:::;„'IL''.'',''''H,1,',,,::;::.,.,,,,:::::;;' 1-''''':1:;;;:::7''''''''';';:11; 4 btoi,,r,,h,,,h,T,,,,,,,,,,,:,,,,,,,,,,,,,,, , 5,,,,,,,, , 1 ,„„.,,,,,, „,,,,,,,,,v, v '";':'z,,:7:':':':::)::''...::::;77:::' ,„,,, ,,ok.,,e427,771.:T-7,r„,, 1,,,, .. 4 f., . < : ''' ''' < I ..rm1.47„.....„„mm"13,,,,,,„:::::!!!:„„,,,,,v,,,, , , 4 6� 0 0 UILDING 2-80 INTF SEE 2-80-2A11) 1 BY APPROVED DATE SYM REVISION PARTIAL FLOO SCALE: 1/8" = BY PLA\ APPROVED DATE RECORD DRAWING J3972197-00. HGI/SDB 11.12.99 A 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 Q�BOE/NGS 13;97 CHRIS EDWARI CARLSON REGISTERED • ;- T CT STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAT B. FERGER CHECKED J. HILLIER ENGINEER C. RISKE DATE 0 0 0 N) 0 0 rp REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 0 2017 City of Tukwila BUILDING DIVISION LEGE\ ID REMOVAL NOT INCLUDED IN PROJECT SCOPE GENERAL DEMOLITION NOTES NOTES ARE COMMON TO THE PROJECT; NOT ALL FLAG NOTES APPEAR ON EACH DEMOLITION PLAN. 2. QUANTITIES OF WORK, WHERE LISTED, ARE ESTIMATES ONLY — GC TO VERIFY TOTAL AMOUNTS IN FIELD. PROTECT AND MAINTAIN CONSTRUCTION NOT SCHEDULED FOR DEMOLITION. MAINTAIN ACCESS TO RESTROOMS AND MECHANICAL ROOMS SCHEDULED TO REMAIN. 4. PROTECT AND MAINTAIN FIRE PROTECTION SYSTEM: MAIN AND ALL HORIZONTAL AND VERTICAL PIPING DURING DEMOLITION. SEE— MECHANICAL. 5. WHERE ELECTRICAL FLOOR RECEPTACLES ARE CALLED OUT TO BE REMOVED ON POWER PLAN REMOVAL DRAWING. FILL PENETRATION WITH CEMENTITIOUS MATERIAL LEVEL WITH EXISTING SLAB. DEvOLITIO\ \OTES REMOVE CARPET + WALL BASE FROM PROJECT AREA. REMOVE ALL CLOCKS AND WHITE BOARDS FROM PROJECT AREA AND RETURN TO PROJECT ADMINISTRATOR. REMOVE ALL SIGNAGE FROM. PROJECT AREA. REMOVE CASEWORK. REMOVE SINK. SEE MECHANICAL. REMOVE ALL VINYL TILE FLOORING. REMOVE DOOR AND FRAME. RELOCATE AS NOTED. CUT OPENING FOR NEW DOOR. REMOVE/ RELOCATE FEC. REMOVE PLYWOOD WALL COVERING. REMOVE GWB PARTITIONS. REMOVE COMPRESSED AIR. REMOVAL W4833402 PERMIT SUBMITTAL 04.07.17 O 2Al2 2-81 BUILDING RECEIVED KEY PLAN • WILA SCALE: NTS APR 1 0 2017 PERMIT CENTER. SUBTITLE PARTIAL SECOND FLOOR PLAN CURRENT REVISION W4833402 SYMBOL DATE 04.07.17 CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F—L/3-8 PLANT 2, WA SHEET 2A13R JOB NO. COMP NO. DWG NO. 2-81-2A13. Ir Dz77z. 0 /in /'')M n 7.1 7.1 A 011 \/ \/ /X\ /X\ OPEN OFFICE AREA - S1 DATA DATA S3 S3 OFFICE S1 OFFICE ` WORK ROOM S1 S1 VISIBILITY ROOM S2 PARTIAL SECO\D FLOO EFLECTED CEILI\G PLA SCALE: 1/8" = 1-0" b`i REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1(1 2111 City of Tukwila BUILDING DIVISION LEGE \D 4'-0"x2'-0" SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING NOT INCLUDED IN PROJECT SCOPE FLUORESCENT LIGHT FIXTURE SUPPLY AIR DIFFUSER RETURN AIR .GRILLE RECESSED DOWNLIGHT EXIT LIGHTS (WALL MOUNTED) 10 EXIT LIGHTS (CEILING MOUNTED) GE\RAL CEILI\G E VOLITIO\ NOTES 1. REFER TO THE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING. THE LIGHT FIXTURES AND OTHER ELECTRICAL DEVICES SHOWN ON THIS SHEET. 2. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING DUCT WORK AND REGISTERS. CEILI\G �E VOLITIO\ \OTES REMOVE ACOUSTIC CEILING TILES IN PROJECT AREA. GRID REMAINS, UNO. REMOVE LIGHT FIXTURES AND ELECTRIC EQUIPMENT FROM CEILING. SEE ELECTRICAL DRAWINGS. REMOVE CEILING TILE AND GRID. REMOVAL W4833402 PERMIT SUBMITTAL 04.07.17 KEY PLAN SCALE: NTS RECEIVED CITY OF TUKWIL:A N APR 10 2017 PERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 Q� BOE/NG G�- CHRIS EDWARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. WILLIAMS DATE CHECKED J. HILLIER SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL A DATE 04.07.17 ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS 2-81 BUILDING ARCHITECTURAL MASTER COL. A -F/1-3 PLANT 2 SHEET 2A280R JOB NO. 972197-00 COMP NO. DWG NO. 2-81-2A280R C C a C 0 c OPE OFFICE AREA 11111111111 x x x x x x x REPRODUCTION WORK ROOM WORK ROOM OFFICE OFFICE HALLWAY ROOM S1 S2 N36 N36 MATCHLINE SEE SHE- 2 WORK ROOM VISIBILTY ROOM N36 N36 HALLWAY PARTIAL SECO\D FL00R DEFLECTED CEILI\G PLA\ REVIEWED FOR CODE COMPLIANCE APPROVED MAY 10 2011 City of Tukwila BUILDING DIVISION LEGE\ D :................. . 4'-0"x2'-0 SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING NOT INCLUDED IN PROJECT SCOPE FLUORESCENT LIGHT FIXTURE SUPPLY AIR DIFFUSER RETURN AIR GRILLE RECESSED DOWNLIGHT EXIT LIGHTS (WALL MOUNTED) EXIT LIGHTS (CEILING MOUNTED) ■ ■ ■ ■ ■ ■ ■ CABLE TRAYS TO BE REMOVED GE\RAL C iu\c DEvourio\ � CTES 1. REFER TO THE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING THE LIGHT FIXTURES AND OTHER ELECTRICAL DEVICES SHOWN ON THIS SHEET. 2. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING DUCT WORK AND REGISTERS. C-1LI\G DEVOLITIO\ \OTES REMOVE ACOUSTIC CEILING TILES IN PROJECT AREA. GRID REMAINS, UNO REMOVE LIGHT FIXTURES AND ELECTRIC. EQUIPMENT FROM CEILING. SEE ELECTRICAL DRAWINGS. REMOVE CEILING TILE AND GRID. REMOVAL W4833402 PERMIT SUBMITTAL 04.07.17 2A280 jj ---------------------- 2A282 2A283 ED CITY OF TUKWILA PR 1 0 2017 PERMIT CENTER CURRENT REVISION SYMBOL A DATE REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS- 2ND FLOOR W4833402 BUFFALO 04.07.17 Q�BOE/NG° 3973 Rif,RED ECT CHRIS EDWARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE APPROVED BY DEPT. DATE CHECKED J. HILLIER ENGINEER C. RISKE SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN W4833402 04.07.17 CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F—L/1-3 PLANT 2 SHEET 2A281 R JOB NO. W4833402 COMP NO. DWG NO. 2-81-2A281 R 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" ;x II!III!UII!III 11 1111 11111111111111 uIuuIuuuI1uIuuuuuIuuuuuHhuuuuHuIuuuII 1111111 111 1 1■1 0 0 CD rD 0 0 r7 2 WED FOR CCOMPLIANCE APPROVED MAY 102017 City of Tukwila BUILD , t � ION PARTIAL SECO SCALE: 1/8" = 1'-0" FLOO EFLECTED CEILI\G PLA\ LEGE\D 9 ■■■■■■■ 4'-0"x2'-0" SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING NOT INCLUDED IN PROJECT SCOPE FLUORESCENT LIGHT FIXTURE SUPPLY AIR DIFFUSER RETURN AIR GRILLE RECESSED DOWNLIGHT EXIT LIGHTS (WALL MOUNTED) EXIT LIGHTS (CEILING MOUNTED) CABLE TRAYS TO BE REMOVED GE\HAL CEILI\G DEvOLIT10\ \OTES 1. REFER TO THE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING THE LIGHT FIXTURES AND OTHER ELECTRICAL DEVICES SHOWN ON THIS SHEET. 2. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING DUCT WORK AND REGISTERS. CEILI\G DEv OLITIO\ \CTES REMOVE ACOUSTIC CEILING TILES IN PROJECT AREA. GRID REMAINS, UNO. REMOVE LIGHT FIXTURES AND ELECTRIC EQUIPMENT FROM CEILING. SEE ELECTRICAL DRAWINGS. REMOVE CEILING MOUNTED PROJECTION SCREEN. REMOVE CEILING TILE AND GRID. REMOVAL W4833402 PERMIT SUBMITTAL 04.07.17 KEY PLAN SCALE: NTS ED KWILA APR 10 2017 MIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 Q� BOE/NGS G�- 3973 REGISTERED •HITECT HRIS i CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE APPROVED BY DEPT. DATE CHECKED J. HILLIER ENGINEER C. RISKE SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL A DATE 04.07.17 CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F -L/1-3 PLANT 2, WA SHEET 2A282R JOB NO. J3972197-00 COMP NO. DWG NO. 2-81-2A282R we u r C C C C 0 r r C 2A280 2A281 j 2A283 �' REChI �rry nc'ri KEY PLAN SCALE: NTS ED KWILA APR 10 2017 MIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 Q� BOE/NGS G�- 3973 REGISTERED •HITECT HRIS i CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE APPROVED BY DEPT. DATE CHECKED J. HILLIER ENGINEER C. RISKE SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL A DATE 04.07.17 CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F -L/1-3 PLANT 2, WA SHEET 2A282R JOB NO. J3972197-00 COMP NO. DWG NO. 2-81-2A282R we u r C C C C 0 r r C PARTIAL FLOOR PLA SCALE: 1/8" = 1'-0 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.28.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE CHECKED J. HILLIER SUBTITLE 6' y LEGE\D X 71 lG_�I 4'-0"x2'-0" SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING NOT INCLUDED IN PROJECT SCOPE FLUORESCENT LIGHT FIXTURE SUPPLY AIR DIFFUSER RETURN AIR GRILLE ;-1 RECESSED DOWNLIGHT EXIT LIGHTS (WALL MOUNTED) } ®} EXIT LIGHTS (CEILING MOUNTED) ®®®®®®® CABLE TRAYS TO BE REMOVED GE\PAL CEILI\ `7 DE v O LITI O \ \OTES 1. REFER TO THE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING THE LIGHT FIXTURES AND OTHER ELECTRICAL DEVICES SHOWN ON THIS SHEET. 2. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING DUCT WORK AND REGISTERS. CEILI \G DE V OLITIO\ \OTES REMOVE ACOUSTIC CEILING TILES IN PROJECT AREA. GRID REMAINS, UNO REMOVE LIGHT FIXTURES AND ELECTRIC EQUIPMENT FROM CEILING. SEE ELECTRICAL DRAWINGS. REMOVE CEILING TILE AND GRID. COMPLIANCE k 'JEi MAY 10 2017 city of Tukwila BUI? iN REMOVAL W4833402 90% RE -SUBMITTAL 04.28.17 2 PARTIAL SECOND FLOOR REFLECTED CEILING PLAN KEY PLAN SCALE: NTS E I V E D CITY O TUKWILA N MAY a3 2017 ERMIT CENTER CURRENT REVISION W4833402 SYMBOL A DATE 04.28.17 APPROVED BY DEPT. DATE ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F -L/3-8 PLANT 2, WA SHEET 2A283R JOB NO. COMP NO. DWG NO. 2-81-2A283R JDB3773: 8/11/2010 9:31:37 AM NM T-- ,,›__._ -,- 1 i ... _ _is.. >,... ro[-,_ _ __I_ 4 ± _ ..L. ____ iz -it z 1 1 \xi 1 1 , 1:•._ , , 1 2-80 F'LDG I r_ L 1 1.. R. ■ a I n] ,>--• m L I 1•:. - 2f r�5 IIIIII ■ II■ SHEER I 9=i--i`-Ji--ice �> 110111 I i MN 1 to i X X II 0 a '01 1 1 01 01 X lo I 11 X X X ill X 11 mil I 1 r IISP1/314011I IX II1 WI LI 111 IA 00 11 PARTIAL FLOOR PLA SCALE: 1/8" = 1'-0 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.28.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE CHECKED J. HILLIER SUBTITLE 6' y LEGE\D X 71 lG_�I 4'-0"x2'-0" SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING NOT INCLUDED IN PROJECT SCOPE FLUORESCENT LIGHT FIXTURE SUPPLY AIR DIFFUSER RETURN AIR GRILLE ;-1 RECESSED DOWNLIGHT EXIT LIGHTS (WALL MOUNTED) } ®} EXIT LIGHTS (CEILING MOUNTED) ®®®®®®® CABLE TRAYS TO BE REMOVED GE\PAL CEILI\ `7 DE v O LITI O \ \OTES 1. REFER TO THE ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING THE LIGHT FIXTURES AND OTHER ELECTRICAL DEVICES SHOWN ON THIS SHEET. 2. REFER TO MECHANICAL DRAWINGS AND SPECIFICATIONS FOR SPECIFIC INFORMATION REGARDING DUCT WORK AND REGISTERS. CEILI \G DE V OLITIO\ \OTES REMOVE ACOUSTIC CEILING TILES IN PROJECT AREA. GRID REMAINS, UNO REMOVE LIGHT FIXTURES AND ELECTRIC EQUIPMENT FROM CEILING. SEE ELECTRICAL DRAWINGS. REMOVE CEILING TILE AND GRID. COMPLIANCE k 'JEi MAY 10 2017 city of Tukwila BUI? iN REMOVAL W4833402 90% RE -SUBMITTAL 04.28.17 2 PARTIAL SECOND FLOOR REFLECTED CEILING PLAN KEY PLAN SCALE: NTS E I V E D CITY O TUKWILA N MAY a3 2017 ERMIT CENTER CURRENT REVISION W4833402 SYMBOL A DATE 04.28.17 APPROVED BY DEPT. DATE ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F -L/3-8 PLANT 2, WA SHEET 2A283R JOB NO. COMP NO. DWG NO. 2-81-2A283R JDB3773: 8/11/2010 9:31:37 AM LEGE \ D EXIST WALLS ALL TYPES NEW WALLS WALL TYPE: STEEL STUD SHADED AREA NOT INCLUDED IN PROJECT SCOPE OFFICE ROOM S3 GE\RAL \OTES CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB BEFORE PROCEEDING WITH THIS WORK. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE PROJECT ARCHITECT FOR CLARIFICATION. PATCH AND REPAIR HOLES AND DENTS TYPICAL THROUGHOUT; MATCH ADJACENT FINISH. SKIM COAT WALL SURFACES WHERE WALL COVERING IS REMOVED. CO\SRUCTIO\ \OTES MATCHLINE SEE SHEET 2Al2 21C2) I 22C2 )01D2 (21D2) (22D2 (23D2) ® 4 4. 17 I 04,1EA0x PRIVACY PRIVACY CONFERENCE CONFERENCE CONFERENCE CONFERENCE CONFERENCE AIL 2/A5XX. MOUNT BOTTOM OF MONITOR 42 AFr. INSTALL BACKING AOR 60" MON{TOR, SCC DCTAIL 2/A5XX MOUNT BOTTOM OF MONITOR 1.2" AFF. INSTALL BACKING FOR 80" MONITOR, SEE DETAIL 2/A5XX. MOUNT BOTTOM OF MONITOR 42" AFF. RELOCATE DOOR REMOVED FROM ROOM 23F6. SEE DETAIL 1 /A5XX PAINT HM DOOR AND FRAME BOTH SIDES. SKIM COAT WALL WHERE PLYWOOD WAS REMOVED. GENERAL NOTES: 1. N.CE55®£ PONE OF TRAWL ROPES NOT N MEID ROW= SLOPE OF 1110 661 CROSS SLOPE OF 150 WN. 2. 571660630610000641302 BY OANER PROJECT INFORMATION 79097 034 TM 0-9 MGM,. - 8 MEA OF .0063FL 31.538 SF Na OF SECOND FLOOR - NO WORN 11379 SF NUL 500019 EMIR Ma 42915 SF 01440 I4600JF16NR- 2113 FLOOR 649.33402 8163 C0090N PAIN OF MESS 11341. 160 10145) < 100 FT FLOOR OCCUPANT LOAD EMS ORO 7,911 1015.1) 2340 FlDOR 315 RID121@ 1 Ka OF NM(PROMO: 2 REVIEWED FOR ',CODE COMPLIANCE {• APPROVED ry jQY�� `1y/ 201/ 1A1 Q- j2A10 PLAN VIEW 1 16 = 1 W4833402 90% SUBMITTAL 04.07.17 W4833402 PERMIT SUBMITTAL 04.07.17 2-81 BUILDING KEY PLAN SCALE: NTS - DATE EX BUT. RECORD DRAWING .3972197-00 !971/518 11.12.99 URD 01440 I4600JF16NR- 2113 FLOOR 649.33402 BUFFALO 04.07.17APPROVED ACCEPTABILITY 738 00060 AW/tll SPFLBNAI9N 6 /P�dhD LIFE SAFETY PLAN - SECOND FLOOR MRIVAT RECEIVED ITV OF TUKWILA APR 10 2017 PERMIT CENTER 3.30.08 COL A -L/1-8 PLANT 2, WA 2-81-A4 REVISION APPROVED REVISION SUBTITLE RECORD DRAWING J#972197-00 2-81 DENSITY IMPROVEMENTS W4833402 HGI/SDB 11.12.99 BUFFALO 04.07.17 g� BOE/NG° - InIJ Ut.J1l71,1 R U/UK SPECIFICATION IS APPROVED APPROVED BY 5../ 1 ILV 11 L.1./ PARTIAL SECOND FLOOR PLAN ENGINEER TITLE 2-81 DENSITY IMPROVEMENTS CURRENT REVISION W4833402 SHEET SYMBOL 04.07.17 CHECKED CHRIS EDWARD CARLSON STATE OF WASHINGTON APPROVED 2-81 3UILD1\ JOB NO. APPROVED ARCHITECTURAL MASTER COL. A -F/1-3 PLANT 2 DWG NO. 972197-00 2-81-2A10 COMP NO. 30,-o" TYP. ALL BAYS U.N.O. 23E4 COLLABORATION 21F2 22G2 23G2 DART AL FLOOR DLA\ CONFERENCE 22H2 CONFERENCE 22H3 CONFERENCE PRIVACY 22J2 21K3 21K4 REVIEWED FOR 'CODE COMPLIANCE APPROVED MAY 10 ?im City of Tukwila BUILDING DIVISION -G \D G .Ps," \""v EXIST WALLS - ALL TYPES NEW WALLS WALL TYPE: STEEL STUD SHADED AREA NOT INCLUDED IN PROJECT SCOPE \ E RA L \OT -S CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB BEFORE PROCEEDING WITH THIS WORK. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE PROJECT ARCHITECT FOR CLARIFICATION. 2. PATCH AND REPAIR HOLES AND DENTS TYPICAL THROUGHOUT; MATCH ADJACENT FINISH. SKIM COAT WALL SURFACES WHERE WALL COVERING IS REMOVED. CO\STRCTO\ \OTES INSTALL BACKING FOR 49" MONITOR, SEE DETAIL 2/A5XX. MOUNT BOTTOM OF MONITOR 42" AFF. TAIL 2/A5XX. TAI; 2/A5XX CLEAN VCT. STRIP FINISH. REMOVE SCUFF MARKS. APPLY ARMSTRONG FLOORING S-495 STAIN RESISTANT SEALER. APPLY (3) COATS ARMSTRONG S-480 COMMERCIAL FLOOR POLISH. RELOCATE DOOR REMOVED FROM ROOM 23F6. SEE DETAIL 1 /A5XX PAINT HM DOOR AND FRAME BOTH SIDES. SKIM COAT WALL WHERE PLYWOOD WAS REMOVED. RELOCATE DOOR FROM FORMER COFFEE ROOM W4833402 PERMIT SUBMITTAL 04.07.17 2-81 BUILDING KEY PLAN RECEIVWS CITY OF TUKWILA APR 1 0 2017 PERMIT CENTER CEIVED CI F TUKWILA APR 10 2017 PERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 i.00:1117:Nr CHRIS EDWARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN B. FERGER DATE CHECKED J. HILLIER SUBTITLE PARTIAL SECOND FLOO PLAN CURRENT REVISION W4833402 SYMBOL DATE 04.07.17 ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPORVEMENTS 2-81 KILDI\G ARCHITECTURAL MASTER COL. F -L/1-3 PLANT 2 SHEET 2A11 JOB NO. 972197-00 COMP NO. 281-2A10 DWG NO. 2-81-2A10 30'-0" 30'-0" 30'-0" 30'-0" 30' ,f CONFERENCE MATCHLINE SEE SHEET 2A10 CONFERENCE SLOPE 22B4 FA1,4 I v PLOT ROOM HALLWAY CANOPY ROOF BELOW PRIVAC PRIVACY WORK ROOM SLOPE SLOPE CONFERENCE CONFERENCE CONFERENCE SLOPE 1/4" PER FOOT MIN. 0 0 0 0 0 0 0 f) LEGE\D GE\ EXIST WALLS - ALL TYPES NEW WALLS WALL TYPE: STEEL STUD SHADED AREA NOT INCLUDED IN PROJECT SCOPE EAL \OTES CHECK AND VERIFY ALL DIMENSIONS AND CONDITIONS ON THE JOB BEFORE PROCEEDING WITH THIS WORK. BRING ANY DISCREPANCIES TO THE ATTENTION OF THE PROJECT ARCHITECT FOR CLARIFICATION. PATCH AND REPAIR HOLES AND DENTS TYPICAL THROUGHOUT; MATCH ADJACENT FINISH. 3 SKIM COAT WALL SURFACES WHERE WALL COVERING IS REMOVED. CO\STUCTIO\ \OTES NEW OPERABLE PARTITION: MODERNFOLD ACOUSTI-SEAL ENCORE SERIES. 56 STC • WELDED STEEL FRAMES AND STEEL SUBSTRATES. • MODERNFOLD'S STANDARD FULL HEIGHT MARKER BOARD FINISHES. • #17 HEAVY-DUTY STEEL TRACK W/HEAVY-DUTY STEEL TROLLEYS. • VINYL (PVC) AUTOMATIC TOP SEALS W/2" MANUAL CRANK -OPERATED BOTTOM SEALS. • EXPANDABLE (CRANK DRIVEN) FINAL CLOSURE PANELS. SEE DETAIL 7/A5XX. INSTALL BACKING FOR 49" MONITOR, SEE DETAIL 2/A5XX. MOUNT BOTTOM OF MONITOR 42" AFF. INSTALL BACKING FOR 60" MONITOR, SEE DETAIL 2/A5XX. MOUNT BOTTOM OF MONITOR 42" AFF. I, C's L J C- JIJIlift/I JL-\LLIC. RELOCATE DOOR REMOVED FROM ROOM 23F6. SEE DETAIL 1 /A5XX PAINT HM DOOR AND FRAME BOTH SIDES. SKIM COAT WALL WHERE PLYWOOD WAS REMOVED. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1 0 2017 0 -411111 City of Tukwila BUILDING111140N RECEIVED CITY OF TUKWILA APR 10 2017 PERMIT CENTER W4833402 PERMIT SUBMITTAL 04.07.1.7 PARTIAL PLA\ VIEW SCALE: 1/8" = 1'-0" 0 2-81 BUILDING SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED RECORD DRAWING J3972197-00 CDC RELOCATION - WIRE SHOP RELOCATION J#19670 RECORD DRAWING J#19670 2-81 DENSITY IMPROVEMENTS W4833402 HGI/SDB DLR GROUP DLR GROUP BUFFALO 11.12.99 11.11.13 04.01.14 04.07.17 Q,�BOE/NG 39 _ REGISTERED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE CHRIS EDWARD CARLSON STATE OF WASHINGTON DRAWN B. FERGER CHECKED J. HILLIER ENCINEER C. RISKE DATE SUBTITLE FLOOR PLAN CURRENT REVISION W4833402 SYMBOL DATE 04.07.17 TITLE 2-81 DENSITY IMPROVEMENTS CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE ARCHITECTURAL MASTER BUILDING 2-81 COL. A -F/3-8 PLANT 2, WA JOB NO. DWG NO. 19670 2 COMP NO. 81-2Al2 u u C h C r. L 30'-0" 30'-0" 30'-0" 30'-0" -�» h h A h h h r • 1 X X E R0 X 4 { X� X X X X X X X X� X X X g X X X X X X � X 1 O } 0 O 0 MATCHLINE SEE SHEET 2A282 PRIVACY PRIVACY CONFERENCE PARTIAL SECO SCALE: 1/8" = 1'-0' 21 C2 21 B3 22C2 CONFERENCE CONFERENCE CONFERENCE CONFERENCE 21D2 \D FL0N EFLECTED CEILI\G PLA\ 22D2 23D2 21E2 LEGE I!I x to of ®I 4'-0"x 2'-0" SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING SHADED AREA NOT INCLUDED IN PROJECT SCOPE SUPPLY AIR DIFFUSER RETURN AIR GRILLE LINEAR LED WALL WASH FIXTURE 2X4 RECESSED LAY—IN LED FIXTURE 2X2 RECESSED LAY—IN LED FIXTURE LINEAR LED ACCENT FIXTURE PENDANT LED DIRECT/INDIRECT LIGHT FIXTURE PENDANT LED DECORATIVE FIXTURE RECESSED LED DECORATIVE FIXTURE RECESSED LED WALL WASH FIXTURE RECESSED LED WALL SCONCE RECESSED LED DOWNLIGHT WALL MOUNTED LED FIXTURE • UNDERCABINET LED FIXTURE EXIT LIGHT FIXTURE, CEILING MOUNTED DIRECTION OF EGRESS NOTED EXIT LIGHT FIXTURE, WALL MOUNTED DIRECTION OF EGRESS NOTED GE\EAL CEILI\G \ OTES 1. ALL ACOUSTIC CEILINGS AND SUSPENSION SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ISSUE INTERNATIONAL BUILDING CODE SEISMIC REQUIREMENTS, SEISMIC ZONE. SEE TYPICAL CEILING DETAILS SHEET A501. 2. REFER TO CEILING PLAN FOR CEILING HEIGHTS AND ROOM FINISHES. ROOMS WITH CEILING HEIGHTS THAT VARY ARE NOTED ON THESE DWGS. CEILING HEIGHTS ARE TAKEN FROM FINISH FLOOR HEIGHTS. 3. Fro Qseraje' a -r\ (`O co.(' (e 4(0 CEILI\G \CTES leVe.l P INSTALL CEILING TILES. ARMSTRONG ULTIMA REGULAR # 1914 LAY IN PANELS, CLASS A, 24"X 48"X 3/4" " REVIEWED FOR QDE COMPLIANCE APPROVED MAY 102017 City of Tukwila 131111.0, �1 1 -4 W4833402 PERMIT SUBMITTAL 04.07.17 KEY PLAN SCALE: NTS IVED -. UKWII.A APR 1 o zmi OERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 3973 REGISTERED ECT ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE APPROVED BY DEPT. DATE CHECKED J. HILLIER ENGINEER C. RISKE SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL A DATE 04.07.17 CHRIS EDWARD CARLSON STATE OF WASHINGTON CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS 2-81 BUILDING ARCHITECTURAL MASTER COL. A—F/1-3 PLANT 2 SHEET 2A280 JOB NO. 972197-00 COMP NO. 281-2A280 DWG NO. 2-81-2A280 �c C a a C j 2A280A 2A281 2A283 IRE 2A282 KEY PLAN SCALE: NTS IVED -. UKWII.A APR 1 o zmi OERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 3973 REGISTERED ECT ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE APPROVED BY DEPT. DATE CHECKED J. HILLIER ENGINEER C. RISKE SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL A DATE 04.07.17 CHRIS EDWARD CARLSON STATE OF WASHINGTON CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS 2-81 BUILDING ARCHITECTURAL MASTER COL. A—F/1-3 PLANT 2 SHEET 2A280 JOB NO. 972197-00 COMP NO. 281-2A280 DWG NO. 2-81-2A280 �c C a a C 30'-0" 30'- „ 30'-0" 30'-0" 14'-0" 111 1 1 ii ii A III" A I 1I 111111 11 C') • 11111111 I I II 2� • MEI 4,5 A5XX EFLECTE3 CEILI\G DLA\ 3) LEGE \ 3 x -O- ° 0 r I G - ®j 4'-0"x 2'-0" SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING SHADED AREA NOT INCLUDED IN PROJECT SCOPE SUPPLY AIR DIFFUSER RETURN AIR GRILLE LINEAR LED WALL WASH FIXTURE 2X4 RECESSED LAY -IN LED FIXTURE 2X2 RECESSED LAY -IN LED FIXTURE LINEAR LED ACCENT FIXTURE PENDANT. LED DIRECT/INDIRECT LIGHT FIXTURE PENDANT LED DECORATIVE FIXTURE RECESSED LED DECORATIVE FIXTURE RECESSED LED WALL WASH FIXTURE RECESSED LED WALL SCONCE RECESSED LED DOWNLIGHT WALL MOUNTED LED FIXTURE UNDERCABINET LED FIXTURE • EXIT LIGHT FIXTURE, CEILING MOUNTED DIRECTION OF EGRESS NOTED • EXIT LIGHT FIXTURE, WALL MOUNTED DIRECTION OF EGRESS NOTED HAL CB_ N G \OTES 1. ALL ACOUSTIC CEILINGS AND SUSPENSION SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ISSUE INTERNATIONAL BUILDING CODE SEISMIC REQUIREMENTS, SEISMIC ZONE. SEE TYPICAL CEILING DETAILS SHEET A501 2.. REFER TO CEILING PLAN FOR CEILING HEIGHTS AND ROOM FINISHES. ROOMS WITH CEILING HEIGHTS THAT VARY ARE NOTED ON THESE DWGS. CEILING HEIGHTS ARE TAKEN FROM FINISH FLOOR HEIGHTS. C ILI\ G \3TES INSTALL CEILING TILES. ARMSTRONG ULTIMA REGULAR # 1914 LAY IN PANELS, CLASS A, 24"X 48"X 3/4" INSTALL CEILING TILES AND GRID. ARMSTRONG 15/16" PRELUDE TXL, WHITE. PROVIDE SEISMIC BRACING -SEE 6/A5XX PAINT GWB CEILING OR SOFFIT. PA -XX REVIEWED FOR CODE COMPLIANCE APPROVED MAY 10 201? City of Tukwila BUILDING DIVISION W4833402 PERMIT SUBMITTAL 04.07.17 WED ICWILA APR 102017 MIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 CHRIS EDWARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K. WILLIAMS DATE CHECKED J. HILLIER SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL A DATE 04.07.17 ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F -L/1-3 SITE SHEET 2A281 JOB NO. COMP NO. DWG NO. 2-81-2A281 C r C r C C C r, r C C 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" II /11 I III VA • V E I II III 1111111111 vow 0 0 1111111111,11 ENE 0 O LEGE\J 0I x 4'-0"x 2'-0" SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING SHADED AREA NOT INCLUDED IN PROJECT SCOPE SUPPLY AIR DIFFUSER RETURN AIR GRILLE LINEAR LED WALL WASH FIXTURE 2X4 RECESSED LAY—IN LED FIXTURE �-0- 2X2 RECESSED LAY—IN LED FIXTURE LINEAR LED ACCENT FIXTURE 10 0 PENDANT LED DIRECT/INDIRECT LIGHT FIXTURE 38f PENDANT LED DECORATIVE FIXTURE RECESSED LED DECORATIVE FIXTURE RECESSED LED WALL WASH FIXTURE RECESSED LED WALL SCONCE RECESSED LED DOWNLIGHT WALL MOUNTED LED FIXTURE UNDERCABINET LED FIXTURE EXIT LIGHT FIXTURE, CEILING MOUNTED DIRECTION OF EGRESS NOTED ..._ EXIT LIGHT FIXTURE, WALL MOUNTED F® DIRECTION OF EGRESS NOTED ®I GE\EAL CEILI\G \OTES 1. ALL ACOUSTIC CEILINGS AND SUSPENSION SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ISSUE INTERNATIONAL BUILDING CODE SEISMIC REQUIREMENTS, SEISMIC ZONE. SEE TYPICAL CEILING DETAILS SHEET A501. 2. REFER TO CEILING PLAN FOR CEILING HEIGHTS AND ROOM FINISHES. ROOMS WITH CEILING HEIGHTS THAT VARY ARE NOTED ON THESE DWGS. CEILING HEIGHTS ARE TAKEN FROM FINISH FLOOR HEIGHTS. CEILI\G \OTES INSTALL CEILING TILES. ARMSTRONG ULTIMA REGULAR # 1914 LAY IN PANELS, CLASS A, 24"X 48"X 3/4" INSTALL CEILING TILES AND GRID. ARMSTRONG 15/16" PRELUDE TXL, WHITE. PROVIDE SEISMIC BRACING -SEE 6/A5XX. PAINT GWB CEILING OR SOFFIT. PA—XX REVIEWED FOR CODE COMPLIANCE APPROVED MAY 107017 City of Tukwila BUM) 3 PARTIAL SECO\D 'EFLECTED SCALE: 1 /8" = 1'-0" CEILI\G PLA\ W4833402 PERMIT SUBMITTAL 04.07.17 KEY PLAN SCALE: NTS CEIVED �:t 1 Y uF TUKWIL APR 10 7017 PERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 ffa!NGm o'— 3973 REGISTERED ARCHITECT ti CHRIS EDWARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE CHECKED J. HILLIER SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL DATE 04.07.17 APPROVED BY DEPT. DATE ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F—L/1-3 PLANT 2, WA SHEET 2A282 JOB NO. J3972197-00 COMP NO. DWG NO. 2-81-2A282 c.r•z WU VPVG/ II,/0 'LLLLCIUI 2A280 2A281 17 /2>2A283 KEY PLAN SCALE: NTS CEIVED �:t 1 Y uF TUKWIL APR 10 7017 PERMIT CENTER REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J3972197-00 HGI/SDB 11.12.99 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 ffa!NGm o'— 3973 REGISTERED ARCHITECT ti CHRIS EDWARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE CHECKED J. HILLIER SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL DATE 04.07.17 APPROVED BY DEPT. DATE ENGINEER C. RISKE CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F—L/1-3 PLANT 2, WA SHEET 2A282 JOB NO. J3972197-00 COMP NO. DWG NO. 2-81-2A282 c.r•z WU VPVG/ II,/0 'LLLLCIUI 30'-0" LEGE\D i\ -0- 0 0' 4'-0"x 2'-0" SUSPENDED CEILING GRID GYPSUM WALLBOARD CEILING SHADED AREA NOT INCLUDED IN PROJECT SCOPE SUPPLY AIR DIFFUSER RETURN AIR GRILLE LINEAR LED WALL WASH FIXTURE 2X4 RECESSED LAY -IN LED FIXTURE 2X2 RECESSED LAY -IN LED FIXTURE LINEAR LED ACCENT FIXTURE PENDANT LED DIRECT/INDIRECT LIGHT FIXTURE PENDANT LED DECORATIVE FIXTURE RECESSED LED DECORATIVE FIXTURE RECESSED LED WALL WASH FIXTURE RECESSED LED WALL SCONCE RECESSED LED DOWNLIGHT WALL MOUNTED LED FIXTURE UNDERCABINET LED FIXTURE EXIT LIGHT FIXTURE, CEILING MOUNTED DIRECTION OF EGRESS NOTED EXIT LIGHT FIXTURE, WALL MOUNTED DIRECTION OF EGRESS NOTED GE\HAL CEILI\G \OTES 1. ALL ACOUSTIC CEILINGS AND SUSPENSION SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH THE CURRENT ISSUE INTERNATIONAL BUILDING CODE SEISMIC REQUIREMENTS, SEISMIC ZONE. SEE TYPICAL CEILING DETAILS SHEET A501. 2. REFER TO CEILING PLAN FOR CEILING HEIGHTS AND ROOM FINISHES. ROOMS WITH CEILING HEIGHTS THAT VARY ARE NOTED ON THESE DWGS. CEILING HEIGHTS ARE TAKEN FROM FINISH FLOOR HEIGHTS. CEILI\ G \OTES REVIEWED FOR 'CODE COMPLIANCE APPROVED MAY 102017 INSTALL CEILING TILES. ARMSTRONG ULTIMA REGULAR # 1914 LAY IN PANELS, CLASS A, 24"X 48"X 3/4" INSTALL CEILING TILES AND GRID. ARMSTRONG 15/16" PRELUDE TXL, WHITE. PROVIDE SEISMIC BRACING -SEE 6/A524 PAINT GWB CEILING OR SOFFIT - PA.1 c'i 0f Tukwila 2A280 2A281 10;'1 2A282 PARTIAL FLOO SCALE: 1/8" = 1'-0 PLA W4833402 90% RE -SUBMITTAL 04.28.17 KEY PLAN SCALE: NTS RECEIVED Y OF TUKWILA MAY 03 2017 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING A 2-81 DENSITY IMPROVEMENTS J3972197-00 W4833402 HGI/SDB BUFFALO 11.12.99 04.28.17 gi..._4ME7M”e ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K. WILLIAMS DATE APPROVED BY DEPT. DATE CHECKED J. HILLIER ENGINEER C. RISKE SUBTITLE PARTIAL SECOND FLOOR REFLECTED CEILING PLAN CURRENT REVISION W4833402 SYMBOL A DATE 04.28.17 CHECKED D. CUSTER APPROVED J. HILLIER APPROVED M. PRITTIE 3.30.98 TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-81 COL. F -L/3-8 PLANT 2, WA SHEET 2A283 JOB NO. COMP NO. DWG NO. 2-81-2A283 \T PAINT F\IS SCHEDULE PAINT MARK MFR. COLOR LOCATION/FINISH P1 GLIDDEN WEDDING WHITE A0071 GENERAL PAINT COLOR - ALL GWB WALLS, CEILING, COLUMNS UNO P2 PPG KASMIRE GRAY 18DC23• MATCH # KNT12-120 HM DOORS & HM DOOR FRAMES P3 PPG MEDITERRANEAN C2 709 MATCH # FAS14-573 ACCENT PAINT COLOR P4 GLIDDEN JASPERWARE A1278 ACCENT PAINT COLOR P5 GLIDDEN SEASIDE VILLAGE A1923 ACCENT PAINT COLOR P6 PPG APPALACHIAN BROWN MATCH # FAS 14-577 ACCENT PAINT COLOR CARPET MARK MFR. STYLE LOCATION CA1 MOHAWK GROUP EMERGING LIGHTS II GT157-898 COLOR: GALACTIC TILE INSTALLATION: MONOLITHIC OPEN OFFICE AND AS NOTED CA2 MOHAWK GROUP PIX II TILE GT158-898 COLOR: GALACTIC TILE INSTALLATION: MONOLITHIC AS NOTED RESILIENT FLOORING MARK MFR. STYLE LOCATION VT1 MANNINGTON COMMERCIAL LINEAR METALLIC STEEL AROALA21 18 xis &x48 STRAIGHT GRAIN & 3"X36" STRAIGHT GRAIN COLLABORATION ROOM & VEND ROOM VT2 MANNINGTON COMMERCIAL LINEAR CHALK AROALA11 3"X36" & X48" COLLABORATION ROOM & VEND ROOM VT2 MANNINGTON COMMERCIAL LINEAR METALLIC JET AROALA22 18"X36" & X48" STRAIGHT GRAIN & 3"X36" STRAIGHT GRAIN COLLABORATION ROOM & VEND ROOM RUBBER BASE MARK MFR. STYLE LOCATION RB1 ROPPE #193 BLACK -BROWN 4" TOPSET ALL WALLS, UNO RB2 ROPPE #193 BLACK -BROWN 4" STRAIGHT CASEWORK AS NOTED SURFACE FINISHES MARK MFR. STYLE LOCATION AP1 KNOLL TEXTILES HARD ROCK W1007/4 QUARTZ 66" WIDE, DO NOT RAILROAD AS NOTED CS1 AVONITE SILVER COMET K3-8585 1/2" THICK COLLABORATION & VEND ROOM COUNTERTOPS CS2 ALKEMI LACE 300 1/2" THICK COLLABORATION FREESTANDING BAR COUNTER PL1 FORMICA CITADEL 1097-58 AS NOTED PL2 TBD TBD TBD PROVIDE AND INSTALL FURNITURE QTY MFR. PRODUCT SPECIFICATION AP1 KENMORE MODEL #41123; 21.7 CUBIC FOOT SIDE BY SIDE REFRIGERATOR OR APPROVED EQUAL. FINISH: STAINLESS STEEL. CS1 WHIRLPOOL 1.6 CUBIC FOOT COUNTERTOP MICROWAVE 1200 WATT COOKING POWER; FINISH: MATTE STAINLESS CS2 MTN PRODUCTS MODEL C&C: RS115 WATER COOLER POINT OF USE. 1 GALLON 13"X13"X38"H. STAINLESS STEEL WITH BLACK FINISH — CONNECT TO WATER SOURCE. G=\ SAL FI \ S H \ OTES 1. NO PAINTING WORK SHALL BEGIN UNTIL AN ONSITE PAINT COORDINATION WALK WITH ARCHITECT. 2. ENSURE PLUMB, SHARP, STRAIGHT, AND CLEAN PAINT TRANSITIONS ON WALLS AND CEILINGS BETWEEN DIFFERENT COLORS OR SURFACE MATERIALS. 3. WHERE TWO DISSIMILAR HEIGHT FLOOR FINISHES MEET AT DOORWAYS LOCATE TRANSITION IN CENTER OF CLOSED DOOR UNO. PAINT ALL WALLS, GYP CEILINGS AND SOFFITS P1 UNO ONE COAT TYPICAL.. 5. ALL PAINTED DOORS AND FRAMES P11 UNO. 6. PAINT GWB COLUMNS P1 TYP 7. PAINT HANDRAILS IN STAIR TOWERS P12, UNO. 8. DO NOT PAINT COLUMNS IN MANUFACTURING AREAS, UNO. A5XX 2'-0" 1/4 TEMPERED GLASS 00 TY DES SCALE: NONE ADWAH TYPES DO, � F \1SHES REVIEWED FOR "CODE COMPLIANCE APPROVED MAY 1 0 8017 City of Tukwila EUILDI .+ SION RECEIVED CITY OF TUKWILA APR 1.0 2017 PERMIT CENTER W4833402 PERMIT SUBMITTAL 04.07.17 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 ORIG 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 ?.mff,Efirzw0 � 3973 REGISTERED TECT HRIS ED ARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN M.CARMIER DATE 03.17.17 CHECKED SUBTITLE FINISH & D00 SCHEDULES CURRENT REVISION W4833402 SYMBOL() SIG DATE 04.07.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE 2-81 DENSITY ARCHITECTURAL MASTER 2-81 3 COL IMPROVEMENTS UIL:II\G .A F/1-3 PLANT 2 SHEET A362 JOB NO. 972197-00 COMP NO. DWG NO. 2-81-2A10 300 SCHEDULE MARK SHEET NO. DOOR SIZE DOOR MAT'L DOOR FINISH FRAME MAT'L FRAME FINISH DOOR TYPE HARDWA E GROUP 1�ye. RATING DETAILS LOCATION NOTES/REMARKS HEAD JAMB SILL HM PT HM PT C HW-LeV N/R 1/A5XX 1/A5XX /L« mAX ® 2A1 1 3'-O" x 7'-0 ' x 1 3/4" HSA/- 1/A5XX 1/A5XX COLLABORATION 22G2 ® 2A11 W- HW- 1/A5XX 1/A5XX CONFERENCE 22H2 (2264 2Al2 D HW- HW- 1/A5XX 1/A5XX PRIVACY 22B4 SEE RECITE DETAIL 8/A5XX (22H6) 2A13 C HW- 1/A5XX 1/A5XX ITAR WORK ROOM 22H6 ® 2A13 Hut!- HW- 1/A5XX 1/A5XX PRIVACY 22K3 HW- 1/A5XX 1 /A5XX A5XX 2'-0" 1/4 TEMPERED GLASS 00 TY DES SCALE: NONE ADWAH TYPES DO, � F \1SHES REVIEWED FOR "CODE COMPLIANCE APPROVED MAY 1 0 8017 City of Tukwila EUILDI .+ SION RECEIVED CITY OF TUKWILA APR 1.0 2017 PERMIT CENTER W4833402 PERMIT SUBMITTAL 04.07.17 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 ORIG 2-81 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 ?.mff,Efirzw0 � 3973 REGISTERED TECT HRIS ED ARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN M.CARMIER DATE 03.17.17 CHECKED SUBTITLE FINISH & D00 SCHEDULES CURRENT REVISION W4833402 SYMBOL() SIG DATE 04.07.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE 2-81 DENSITY ARCHITECTURAL MASTER 2-81 3 COL IMPROVEMENTS UIL:II\G .A F/1-3 PLANT 2 SHEET A362 JOB NO. 972197-00 COMP NO. DWG NO. 2-81-2A10 COLLABORATION 21 F2 E\ LAKED PLA\ COLLA3NATIO\ 21F2 2A11 A4XX SCALE: 1/4" = 1'-0" PENDANT A4XXa A4XXa E\LAKED PLA\ (2� VE\DI\G 23F6 2A13 A4XX SCALE: 1/4" = 1'-0" A4XXa LIGHT FIXTURE rI--i---' 'l -_TIT_ -J' ICOF_(-CCI -I -- — 1____i— r -1 — ,--7-fr'N"--., ,.-,,,,:\ • r ,,„-- N. ._ , .--7Cc ICO�CC, r-'1 r-1 r WATER CD N -1 r -I r MICROWAVE MICROWAVE MICROWAVE CS1 BACKSPLASH CS1 BACKSPLASH ,"./ O N LANDFILL LANDFILL RECYCLE RECYCL .4- M 36/' (2) EQ 30" CLR ADJ SHELF 36" (2) EQ „A „A COLABORATION 21F2 EAST INTERIOR ELEVATION ADJ SHELF SCALE: 3/8" = 1'-0" 2A111A4XXa AND COUNTER PL1 CABINET CASEWORK AND COUNTER PL1 CABINET CASEWORK A4XXa E\ LARGED PLA\ � COLLA3CAT10\ 3A 2A11 A4XX SCALE: 1/4" = r MICR )WAVE O VEPD 1r VE 6" ADJ SHELF 4.4 COLABORATION 21F2 SOUTH INTERIOR ELEVATION EXISTING COLUMN SCALE: 3/8" = 1'-0" 21F2 2A11 A4XXa 1 A4XX 0 a COLABORATION 21F2 BAR INTERIOR ELEVATION SCALE: 3/8" = 1'-0" 2A11A4XXa A4XXa A4XXa (E) COLUMN COUNTER: CS.2 OVER SUBSTRATE STL. TUBE . SUPPORT AT 31-0 O.C. MAX., TYP. PL.4 OVER SUBSTRATE, TYP. RB.2 OVER P.LAM, TYP. VENDING 23F6 EAST INTERIOR ELEVATION SCALE: 3/8" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED 2A111A4XXa NAY 10 2017 City of Tukwila BUILDING Dd4J-ON RECEIVED CITY OF TUIKWILA APR 10 2017 PERMIT CENTER W4833402 PERMIT SUBMITTAL 04.07.17 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 2-081 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 ME'NG° o'— ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE CHECKED ENGINEER SUBTITLE INTERIOR ELEVATIONS - 2ND FLOOR CURRENT REVISION W4833402 SYMBOL() SIG DATE 04.07.17 CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-25 PLANT 2 SHEET A4XX JOB NO. W4833402 COMP NO. DWG NO. 2-25-A4XX r - 1 r 1 r -1 `- `� - VED ® VEND ®.(12144, REF ICO�CC, r-'1 r-1 '`1 - . - ---,--........ ,„..... -..------T? -- 4 ,, VENDING 23F6 EAST INTERIOR ELEVATION SCALE: 3/8" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED 2A111A4XXa NAY 10 2017 City of Tukwila BUILDING Dd4J-ON RECEIVED CITY OF TUIKWILA APR 10 2017 PERMIT CENTER W4833402 PERMIT SUBMITTAL 04.07.17 SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 2-081 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 ME'NG° o'— ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DATE CHECKED ENGINEER SUBTITLE INTERIOR ELEVATIONS - 2ND FLOOR CURRENT REVISION W4833402 SYMBOL() SIG DATE 04.07.17 CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER BUILDING 2-25 PLANT 2 SHEET A4XX JOB NO. W4833402 COMP NO. DWG NO. 2-25-A4XX L BASE PLATE DETAIL l?S CO LLA3O AT10 \ 3AB SECTIO \ 2A11 A4XXa SCALE: 1-1/2"=l'—O" COUNTER: CS.2 OVER 3/4" SUBSTRATE 2" TUBE STEEL TEE SUPPORT (AS INDICATED ON ENLARGED PLAN) AND BOLTED TO STUD FRAMING, CAP EXPOSED ENDS PL.4 OVER 1/2" SUBSTRATE 6" X 20 GA METAL STUD FRAMING COUNTER BASE CONT. STL. TRACK — FASTEN TO (E) CONC. AT 4'-0" O.C. MIN., TYP. FLOORING AS SCHEDULED rTh CAS EW0 H < SECTIO\ 2A11 2A13IA4XXaSCALE: 1-1/2"=1 —0" AT SI\ 1/2" SOLID SURFACE COUNTER OVER 1/2" SUBSTRATE SEALANT (E) GLAZING SYSTEM ADHERE P.LAM ON TOP AND FRONT FACES OF EXISTING WINDOW SILL NOTE: AT 3RD FLOOR, EXTEND P—LAM TO COUNTER 16" X 18 1/2" 18 GA STAINLESS STEEL UNDERMOUNT SINK 2" TUBE STEEL SUPPORT BOLTED TO STUD FRAMING, EXTENDED TO FLOOR LEVEL REMOVABLE P.LAM PANEL; ATTACHED W/ SCREWS AND BEAUTY WASHERS NOTES: 1. P.LAM ALL EXPOSED SURFACES AT CABINETS TYP THROUGHOUT UNO 2. P.LAM OVER 3/4" WATER RESISTANT PARTICLE BOARD AT WET LOCATIONS TYP CAS EW0 R 2A11 2A13 A4XXa SCALE: 1-1/2"=1'-0" 'K SECTIO\ SOLID SURFACE COUNTER TOP OVER 1/2" SUBSTRATE SEALANT. COLOR TO MATCH COUNTER MTL BLOCKING — SEE 9/A517 DRAWER WHERE SHOWN IN ELEVATION WIRE PULLS — AMEROCK BP29111G10 (1) ADJ SHELF OR AS SHOWN ON ELEVATIONS BLACK MELAMINE ALL INTERIOR SURFACES, TYP P.LAM OVER 3/4" SUBSTRATE AT ALL EXTERIOR AND EXPOSED SURFACES, TYP. BASE AS NOTED ON FINISH PLAN r -I MICROWAVE SHELF WHERE SHOWN IN ELEVATION SEE ELEVATIONS UNDER CABINET. LIGHTING WHERE INDICATED ON ELECTRICAL DRAWINGS MTL SHEET BLOCKING FULL HIGHT P -LAM BACKSPLASH 8"d OPENING IN COUNTER; WRAP WITH STAINLESS STEEL SOLID SURFACE COUNTER TOP OVER 1/2" SUBSTRATE SEALANT COLOR TO MATCH COUNTER TOP SEE ELEVATIONS � TYP. SECTIO\ A4XX A4XXaSCALE: 1-1 /2"=1'-0" J MTL SHEET BLOCKING BLACK MELAMINE INTERIOR OF WASTE CASEWORK CABINET WIRE PULLS — AMEROCK BP29111G10 P.LAM OVER 3/4" SUBSTRATE AT ALL EXTERIOR AND EXPOSED SURFACES, TYP CONTINUOUS STEEL Z—BAR W/0 RETURNS RUBBER BASE AT TOE KICK AND INSIDE TRASH CABINET. AS NOTED ON FINISH PLAN AT WASTE CA3I\ET W4833402 PERMIT SUBMITTAL 04.07.17 FOR `CODE COMPLIANCE APPROVED REVIEWED ‘FOR City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 10 2017 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 2-081 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 3973 REGISTERED ARCHITECT CHRIS E� 'ARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE APPROVED BY DEPT. DATE CHECKED ENCINEER SUBTITLE INTERIOR ELEVATIONS - 2ND FLOOR CURRENT REVISION W4833402 SYMBOL° sic DATE 04.07.17 CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS BUILDING 2-25. ARCHITECTURAL MASTER PLANT 2 SHEET A4XXa JOB NO. W4833402 COMP NO. DWG NO. 2-25—A4XX ADJACENT COUNTER 0 1 1 L 20" 8" CLR .._._......._ ._......_..__........... , T 4" I, — .............._._.__..._._._... — ._._.... 1 _._.._.._._.__... _.. rTh CAS EW0 H < SECTIO\ 2A11 2A13IA4XXaSCALE: 1-1/2"=1 —0" AT SI\ 1/2" SOLID SURFACE COUNTER OVER 1/2" SUBSTRATE SEALANT (E) GLAZING SYSTEM ADHERE P.LAM ON TOP AND FRONT FACES OF EXISTING WINDOW SILL NOTE: AT 3RD FLOOR, EXTEND P—LAM TO COUNTER 16" X 18 1/2" 18 GA STAINLESS STEEL UNDERMOUNT SINK 2" TUBE STEEL SUPPORT BOLTED TO STUD FRAMING, EXTENDED TO FLOOR LEVEL REMOVABLE P.LAM PANEL; ATTACHED W/ SCREWS AND BEAUTY WASHERS NOTES: 1. P.LAM ALL EXPOSED SURFACES AT CABINETS TYP THROUGHOUT UNO 2. P.LAM OVER 3/4" WATER RESISTANT PARTICLE BOARD AT WET LOCATIONS TYP CAS EW0 R 2A11 2A13 A4XXa SCALE: 1-1/2"=1'-0" 'K SECTIO\ SOLID SURFACE COUNTER TOP OVER 1/2" SUBSTRATE SEALANT. COLOR TO MATCH COUNTER MTL BLOCKING — SEE 9/A517 DRAWER WHERE SHOWN IN ELEVATION WIRE PULLS — AMEROCK BP29111G10 (1) ADJ SHELF OR AS SHOWN ON ELEVATIONS BLACK MELAMINE ALL INTERIOR SURFACES, TYP P.LAM OVER 3/4" SUBSTRATE AT ALL EXTERIOR AND EXPOSED SURFACES, TYP. BASE AS NOTED ON FINISH PLAN r -I MICROWAVE SHELF WHERE SHOWN IN ELEVATION SEE ELEVATIONS UNDER CABINET. LIGHTING WHERE INDICATED ON ELECTRICAL DRAWINGS MTL SHEET BLOCKING FULL HIGHT P -LAM BACKSPLASH 8"d OPENING IN COUNTER; WRAP WITH STAINLESS STEEL SOLID SURFACE COUNTER TOP OVER 1/2" SUBSTRATE SEALANT COLOR TO MATCH COUNTER TOP SEE ELEVATIONS � TYP. SECTIO\ A4XX A4XXaSCALE: 1-1 /2"=1'-0" J MTL SHEET BLOCKING BLACK MELAMINE INTERIOR OF WASTE CASEWORK CABINET WIRE PULLS — AMEROCK BP29111G10 P.LAM OVER 3/4" SUBSTRATE AT ALL EXTERIOR AND EXPOSED SURFACES, TYP CONTINUOUS STEEL Z—BAR W/0 RETURNS RUBBER BASE AT TOE KICK AND INSIDE TRASH CABINET. AS NOTED ON FINISH PLAN AT WASTE CA3I\ET W4833402 PERMIT SUBMITTAL 04.07.17 FOR `CODE COMPLIANCE APPROVED REVIEWED ‘FOR City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 10 2017 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 2-081 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 3973 REGISTERED ARCHITECT CHRIS E� 'ARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE APPROVED BY DEPT. DATE CHECKED ENCINEER SUBTITLE INTERIOR ELEVATIONS - 2ND FLOOR CURRENT REVISION W4833402 SYMBOL° sic DATE 04.07.17 CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS BUILDING 2-25. ARCHITECTURAL MASTER PLANT 2 SHEET A4XXa JOB NO. W4833402 COMP NO. DWG NO. 2-25—A4XX CONFERENCE 21D5, 22D5, 21E5 INTERIOR ELEVATION SCALE: 3/8" = 1'-0" f .1111111111 2Al2IA4XXb • + + + + " + + + f 1 l wo J 0 U CONFERENCE 21D5, 22D5, 21E5 TRACK LAYOUT SCALE: 3/8" = 1'-0" (31 — A4XXb 1 W4833402 PERMIT SUBMITTAL 04.07.17 REVIEWED FOR CODE COMPLIANCE APPROVED MAY .10 2017 City of Tukwila BUIi4l RECEIVED CITY OF TUKWILA APR 10 2017 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 2-081 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 Q� BOE/NG C'- 3973 REGISTERED ARCHITECT CHRIS EDWARD CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE APPROVED BY DEPT. DATE CHECKED NCINEER SUBTITLE INTERIOR ELEVATIONS - 2ND FLOOR CURRENT REVISION W4833402 SYMBOL() SIG DATE 04.07.17 CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS BUILDING 2-25 ARCHITECTURAL MASTER PLANT 2 SHEET A4XXb JOB NO. W4833402 COMP NO. DWG NO. 2-25—A4XX 2) 6" METAL STUDS 16 GAUGE) SEE PLAN FOR PARTITION TYPE AND RATING 2" DOOR OPENING 5/8" K N FRAMING ANCHORS HOLLOW METAL FRAME TYPICAL PATTITIC\ JAv3 DETAIL (HEAD SINILA� TYP 5XX SCALE: 3"=1'-0" DOOR, SIDE VARIES ,„\ c/4-/ +\` +' 20 STRUCTURE ATF 12' O.C., TYP. 20 GA. STUD BRACE AT 4'-0" O.C., AT ALTERNATE SIDES OF PPRTITION, TYP. COPE WEB AND FASTEN TO TOP TRACK OF PARTITION AND TO 20 GA. DEEP LEG TRACK AT UNDERSIDE OF (E) DECK ABOVE SEE RCP SUSPENDED ACOUSTICAL CEILING COVE LIGHT KERFORE MDF FLEXBOARD (E) 3 5/8," 20 GA. STUD AT 24 O.C., TYP. (1) LAYER OF 5/8'> GWB, TYP 8" (4 C,;\/' -D LIGHT COVE 2A281 A5XX SCALE: 3"=1 -0" (E) ICAL StALANl, IYV. FILL CAVITY WITH BATT INSUALTION STEEL BEAM 2 LAYERS OF 5/8” GWB FASTENERS BY DOOR MFR MTL. STUD FRAMING 12" +7'-9" A.F.F. SUSPENDED ACOUSTICAL CEILING OPERABLE WALL MANUAL DROP SEAL <I • V 4 ;44 OPERABLE 300SECTIC\ 4 4 2Al2 I A5XX SCALE: 3"=1 -0" n TYPICAL SU TYP A5XX SCALE: N.T.S. 16 GA TRACK - SNIP & BEND FLANGE AT EACH STUD - SPAN (2) STUDS, MIN. SECURE AT EACH STUD WITH (3) #8 SELF -TAPPING PAN HEAD SHEET METAL SCREWS STUD AS SCHEDULED DO 3AC 20 GA. STUD BRACE AT 4'-0" O.C., TYP. COPE WEB AND FASTEN TO TOP TRACK OF PARTITION AND TO 20 GA. DEEP LEG TRACK AT UNDERSIDE OF DECK ABOVE 35/8"X25GA. STUDS © 24" O.C. 5/8" GWB TYP _SOFFIT SECTIO\ 2A281I A517 SCALE: 3"=1'-0" (8� A5XX TYP SCALE: 3 5/8" X 25 GA. STUDS © 24" O.C. 5/8" GWB (2) 3 5/8" X 20 GA. STUDS CORNER BEAD ACOUSTICAL BATT INSULATION (2) 16 GA METAL STUDS 1/4" SHIM SPACE HM RELITE FRAME METAL STOP 1/4" TEMPERED GLASS METAL STOP HM RELITE FRAME (2) 16 GA METAL STUDS -LITE HEAD/SILL SET FASTENER IN SEALANT, /TY 1 •. •••• LAY ACOUSTICAL INSULATION OVER TOP OF WALL AND EXTEND 6' ON BOTH SIDES OF WALL 1 / GQ. STUD BRACE AT 4 -0 O.C. AT ALTERNATE SIDES WEBPARTITION, ANDT A STEN T O TOP TRACK OF PARTITION AND TO UNDERSIDE OF (E) DECK. 7) C 5CTIS) ) A jN�T, Yr: SUSPENDED CEILING SYSTEM (1) LAYER 5/8" TYPE 'X' GWB AT A. FACE OF WALL. FINISH ALL JOINTS, TYP. 3-5/8" 25 GA. STL. STUD AT 24" 0.C., TYP. PROVIDE CONT. BRIDGING AT 4'-0" O.C, TYP. 3 1/2" ACOUSTICAL BATT INSULATION, n a 1, PA. TTI 0 \ HEAD (3A3OVE ACOUSTICAL CEILI\G TYP A5XX SCALE: 3"= V-0 Q. VERTICAL HANGER WIRE: LATERAL BRACING: 12 GA. © 4'-0"O.C.�� 4-#12 GA.WIRES IN PLANE IN BOTH DIRECTIONS OF EACH RUNNER 4 FULL -43111641b MIN. AND AT EACH END. TURNS AT EACH END. 4011 451 W 45° MAX, CONDUIT OR STRUT AT 12'-0" O.C. EACH WAY. START FIRST STRUT POINT WITHIN 6'-0" FROM EACH WALL. PROVIDE SIZE OF STRUT PER UBC STANDARD NO. 25-2. INSTALL SYSTEM PER UBC CHAPTER 25 AND UBC STANDARD NO. 25-2 n SUSPE J REFER TO MAIN RUNNER CROSS RUNNER ACOUSTICAL PANEL 2"MAX. FROM BRACE WIRES TO CROSS RUNNER NOTE: LIGHT FIXTURES TO BE INSTALLED PER UBC CHAPTER 25-2 10 Ate. ED CEILI\G SYSTE V ALL A5XX SCALE: SCALE: NONE GENERAL NOTES \ON-LOAD-3EARING STEEL FRAMING: FRAMING MEMBERS, GENERAL: COMPLY WITH ASTM C 754 FOR CONDITIONS INDICATED. STEEL SHEET COMPONENTS: COMPLY WITH ASTM C 645 REQUIREMENTS FOR METAL, UNLESS OTHERWISE INDICATED. PROTECTIVE COATING: ASTM A 653/A 653M, G40, UNLESS OTHERWISE INDICATED. STEEL STUDS AND RUNNERS: ASTM C 645. MINIMUM BASE -METAL THICKNESS: 0.027 INCH (0.7 MM). FLAT STRAP AND BACKING PLATE: STEEL SHEET FOR BLOCKING AND BRACING IN LENGTH AND WIDTH INDICATED. MINIMUM BASE -METAL THICKNESS: 0.0312 INCH (0.79 MM). COLD -ROLLED CHANNEL BRIDGING: 0.0538 -INCH (1.37 -MM) BARE -STEEL THICKNESS, WITH MINIMUM 1/2 -INCH (12.7 MM) WIDE FLANGES. FASTENERS FOR METAL FRAMING: OF TYPE, MATERIAL, SIZE, CORROSION RESISTANCE, HOLDING POWER, AND OTHER PROPERTIES REQUIRED TO FASTEN STEEL MEMBERS TO SUBSTRATES. EXAMINATION: EXAMINE AREAS AND SUBSTRATES, WITH INSTALLER PRESENT, AND INCLUDING WELDED HOLLOW -METAL FRAMES, CAST -IN ANCHORS, AND STRUCTURAL FRAMING, FOR COMPLIANCE WITH REQUIREMENTS AND OTHER CONDITIONS AFFECTING PERFORMANCE. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. INSTALLATION STANDARD: ASTM C 754, EXCEPT COMPLY WITH FRAMING SIZES AND SPACING INDICATED. PROVIDE ALL SPECIALTY ITEMS AND TYPICAL FRAMING DETAILS REQUIRED FOR A NORMAL AND COMPLETE INSTALLATION OF THE FRAMING SYSTEM. INSTALL SUPPLEMENTARY FRAMING, AND BLOCKING TO SUPPORT FIXTURES, EQUIPMENT SERVICES, HEAVY TRIM, GRAB BARS, TOILET ACCESSORIES, FURNISHINGS, OR SIMILAR CONSTRUCTION. INSTALL BRACING AT TERMINATIONS IN ASSEMBLIES. DO NOT BRIDGE BUILDING CONTROL AND EXPANSION JOINTS WITH NON -LOAD-BEARING STEEL FRAMING MEMBERS. FRAME BOTH SIDES OF JOINTS INDEPENDENTLY. SUSPEND HANGERS FROM BUILDING STRUCTURE AS FOLLOWS: INSTALL HANGERS PLUMB AND FREE FROM CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING PLENUM THAT ARE NOT PART OF SUPPORTING STRUCTURAL OR SUSPENSION SYSTEM. SPLAY HANGERS ONLY WHERE REQUIRED TO MISS OBSTRUCTIONS AND OFFSET RESULTING HORIZONTAL FORCES BY BRACING, COUNTERSPLAYING, OR OTHER EQUALLY EFFECTIVE MEANS. WIRE HANGERS: SECURE BY LOOPING AND WIRE TYING, EITHER DIRECTLY TO STRUCTURES OR TO INSERTS, EYE SCREWS, OR OTHER DEVICES AND FASTENERS THAT ARE SECURE AND APPROPRIATE FOR SUBSTRATE, AND IN A MANNER THAT WILL NOT CAUSE HANGERS TO DETERIORATE OR OTHERWISE FAIL. FLAT HANGERS: SECURE TO STRUCTURE, INCLUDING INTERMEDIATE FRAMING MEMBERS, BY ATTACHING TO INSERTS, EYE SCREWS, OR OTHER DEVICES AND FASTENERS THAT ARE SECURE AND APPROPRIATE FOR STRUCTURE AND HANGER, AND IN A MANNER THAT WILL. NOT CAUSE HANGERS TO DETERIORATE OR OTHERWISE FAIL. ASTM C 754 INCLUDES TABULATIONS OF MAXIMUM FRAMING SPACING BASED ON THICKNESS AND ORIENTATION OF GYPSUM BOARD PANELS AND DEFLECTION AND LATERAL LOADING. SLIP -TYPE HEAD JOINTS: WHERE FRAMING EXTENDS TO OVERHEAD STRUCTURAL SUPPORTS, INSTALL TO PRODUCE JOINTS AT TOPS OF FRAMING . SYSTEMS THAT PREVENT AXIAL LOADING OF FINISHED ASSEMBLIES. DOOR OPENINGS: SCREW VERTICAL STUDS AT JAMBS TO JAMB ANCHOR CLIPS ON DOOR FRAMES; INSTALL RUNNER TRACK SECTION (FOR CRIPPLE STUDS) AT HEAD AND SECURE TO JAMB STUDS. FIRE -RESISTANCE -RATED PARTITIONS: INSTALL FRAMING TO COMPLY WITH FIRE -RESISTANCE -RATED ASSEMBLY INDICATED AND SUPPORT CLOSURES AND TO MAKE PARTITIONS CONTINUOUS FROM FLOOR TO UNDERSIDE OF SOLID STRUCTURE. INSTALLATION TOLERANCE: INSTALL EACH FRAMING MEMBER SO FASTENING SURFACES VARY NOT MORE THAN 1/8 INCH (3 MM) FROM THE PLANE FORMED BY FACES OF ADJACENT FRAMING. RESILIENT CHANNEL INSTALLATION: INSTALL RESILIENT CHANNELS FOR ACOUSTICAL WALLS TO PROVIDE SEPARATION BETWEEN METAL FRAMING AND GYPSUM WALLBOARD. DO NOT ALLOW ANY FRAMING, BLOCKING OR MECHANICAL, PLUMBING AND ELECTRICAL WORK TO BRIDGE BETWEEN FREE RESILIENT CHANNEL FLANGE AND WALL FRAMING. REVIEWED FOR CODE COMPLIANCE APPROVED W4833402 PERMIT SUBMITTAL 04.07.17 MAY 102011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2017 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 2-081 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 3973 REGISTERED lob ARCHITECT fifIRIS I ED ' II CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN BUFFALO DATE 04.07.17 CHECKED SUBTITLE MISCELLANEOUS SECTIONS AND DETAILS CURRENT REVISION W4833402 SYMBOLC R I G DATE 04.07.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER 2-81 BUILDING SHEET A5XX JOB NO. W1854280 COMP NO. DWG NO. 2-81-A5XX �..: „ . CONT. ACOUST (E) ICAL StALANl, IYV. FILL CAVITY WITH BATT INSUALTION STEEL BEAM 2 LAYERS OF 5/8” GWB FASTENERS BY DOOR MFR MTL. STUD FRAMING 12" +7'-9" A.F.F. SUSPENDED ACOUSTICAL CEILING OPERABLE WALL MANUAL DROP SEAL <I • V 4 ;44 OPERABLE 300SECTIC\ 4 4 2Al2 I A5XX SCALE: 3"=1 -0" n TYPICAL SU TYP A5XX SCALE: N.T.S. 16 GA TRACK - SNIP & BEND FLANGE AT EACH STUD - SPAN (2) STUDS, MIN. SECURE AT EACH STUD WITH (3) #8 SELF -TAPPING PAN HEAD SHEET METAL SCREWS STUD AS SCHEDULED DO 3AC 20 GA. STUD BRACE AT 4'-0" O.C., TYP. COPE WEB AND FASTEN TO TOP TRACK OF PARTITION AND TO 20 GA. DEEP LEG TRACK AT UNDERSIDE OF DECK ABOVE 35/8"X25GA. STUDS © 24" O.C. 5/8" GWB TYP _SOFFIT SECTIO\ 2A281I A517 SCALE: 3"=1'-0" (8� A5XX TYP SCALE: 3 5/8" X 25 GA. STUDS © 24" O.C. 5/8" GWB (2) 3 5/8" X 20 GA. STUDS CORNER BEAD ACOUSTICAL BATT INSULATION (2) 16 GA METAL STUDS 1/4" SHIM SPACE HM RELITE FRAME METAL STOP 1/4" TEMPERED GLASS METAL STOP HM RELITE FRAME (2) 16 GA METAL STUDS -LITE HEAD/SILL SET FASTENER IN SEALANT, /TY 1 •. •••• LAY ACOUSTICAL INSULATION OVER TOP OF WALL AND EXTEND 6' ON BOTH SIDES OF WALL 1 / GQ. STUD BRACE AT 4 -0 O.C. AT ALTERNATE SIDES WEBPARTITION, ANDT A STEN T O TOP TRACK OF PARTITION AND TO UNDERSIDE OF (E) DECK. 7) C 5CTIS) ) A jN�T, Yr: SUSPENDED CEILING SYSTEM (1) LAYER 5/8" TYPE 'X' GWB AT A. FACE OF WALL. FINISH ALL JOINTS, TYP. 3-5/8" 25 GA. STL. STUD AT 24" 0.C., TYP. PROVIDE CONT. BRIDGING AT 4'-0" O.C, TYP. 3 1/2" ACOUSTICAL BATT INSULATION, n a 1, PA. TTI 0 \ HEAD (3A3OVE ACOUSTICAL CEILI\G TYP A5XX SCALE: 3"= V-0 Q. VERTICAL HANGER WIRE: LATERAL BRACING: 12 GA. © 4'-0"O.C.�� 4-#12 GA.WIRES IN PLANE IN BOTH DIRECTIONS OF EACH RUNNER 4 FULL -43111641b MIN. AND AT EACH END. TURNS AT EACH END. 4011 451 W 45° MAX, CONDUIT OR STRUT AT 12'-0" O.C. EACH WAY. START FIRST STRUT POINT WITHIN 6'-0" FROM EACH WALL. PROVIDE SIZE OF STRUT PER UBC STANDARD NO. 25-2. INSTALL SYSTEM PER UBC CHAPTER 25 AND UBC STANDARD NO. 25-2 n SUSPE J REFER TO MAIN RUNNER CROSS RUNNER ACOUSTICAL PANEL 2"MAX. FROM BRACE WIRES TO CROSS RUNNER NOTE: LIGHT FIXTURES TO BE INSTALLED PER UBC CHAPTER 25-2 10 Ate. ED CEILI\G SYSTE V ALL A5XX SCALE: SCALE: NONE GENERAL NOTES \ON-LOAD-3EARING STEEL FRAMING: FRAMING MEMBERS, GENERAL: COMPLY WITH ASTM C 754 FOR CONDITIONS INDICATED. STEEL SHEET COMPONENTS: COMPLY WITH ASTM C 645 REQUIREMENTS FOR METAL, UNLESS OTHERWISE INDICATED. PROTECTIVE COATING: ASTM A 653/A 653M, G40, UNLESS OTHERWISE INDICATED. STEEL STUDS AND RUNNERS: ASTM C 645. MINIMUM BASE -METAL THICKNESS: 0.027 INCH (0.7 MM). FLAT STRAP AND BACKING PLATE: STEEL SHEET FOR BLOCKING AND BRACING IN LENGTH AND WIDTH INDICATED. MINIMUM BASE -METAL THICKNESS: 0.0312 INCH (0.79 MM). COLD -ROLLED CHANNEL BRIDGING: 0.0538 -INCH (1.37 -MM) BARE -STEEL THICKNESS, WITH MINIMUM 1/2 -INCH (12.7 MM) WIDE FLANGES. FASTENERS FOR METAL FRAMING: OF TYPE, MATERIAL, SIZE, CORROSION RESISTANCE, HOLDING POWER, AND OTHER PROPERTIES REQUIRED TO FASTEN STEEL MEMBERS TO SUBSTRATES. EXAMINATION: EXAMINE AREAS AND SUBSTRATES, WITH INSTALLER PRESENT, AND INCLUDING WELDED HOLLOW -METAL FRAMES, CAST -IN ANCHORS, AND STRUCTURAL FRAMING, FOR COMPLIANCE WITH REQUIREMENTS AND OTHER CONDITIONS AFFECTING PERFORMANCE. PROCEED WITH INSTALLATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. INSTALLATION STANDARD: ASTM C 754, EXCEPT COMPLY WITH FRAMING SIZES AND SPACING INDICATED. PROVIDE ALL SPECIALTY ITEMS AND TYPICAL FRAMING DETAILS REQUIRED FOR A NORMAL AND COMPLETE INSTALLATION OF THE FRAMING SYSTEM. INSTALL SUPPLEMENTARY FRAMING, AND BLOCKING TO SUPPORT FIXTURES, EQUIPMENT SERVICES, HEAVY TRIM, GRAB BARS, TOILET ACCESSORIES, FURNISHINGS, OR SIMILAR CONSTRUCTION. INSTALL BRACING AT TERMINATIONS IN ASSEMBLIES. DO NOT BRIDGE BUILDING CONTROL AND EXPANSION JOINTS WITH NON -LOAD-BEARING STEEL FRAMING MEMBERS. FRAME BOTH SIDES OF JOINTS INDEPENDENTLY. SUSPEND HANGERS FROM BUILDING STRUCTURE AS FOLLOWS: INSTALL HANGERS PLUMB AND FREE FROM CONTACT WITH INSULATION OR OTHER OBJECTS WITHIN CEILING PLENUM THAT ARE NOT PART OF SUPPORTING STRUCTURAL OR SUSPENSION SYSTEM. SPLAY HANGERS ONLY WHERE REQUIRED TO MISS OBSTRUCTIONS AND OFFSET RESULTING HORIZONTAL FORCES BY BRACING, COUNTERSPLAYING, OR OTHER EQUALLY EFFECTIVE MEANS. WIRE HANGERS: SECURE BY LOOPING AND WIRE TYING, EITHER DIRECTLY TO STRUCTURES OR TO INSERTS, EYE SCREWS, OR OTHER DEVICES AND FASTENERS THAT ARE SECURE AND APPROPRIATE FOR SUBSTRATE, AND IN A MANNER THAT WILL NOT CAUSE HANGERS TO DETERIORATE OR OTHERWISE FAIL. FLAT HANGERS: SECURE TO STRUCTURE, INCLUDING INTERMEDIATE FRAMING MEMBERS, BY ATTACHING TO INSERTS, EYE SCREWS, OR OTHER DEVICES AND FASTENERS THAT ARE SECURE AND APPROPRIATE FOR STRUCTURE AND HANGER, AND IN A MANNER THAT WILL. NOT CAUSE HANGERS TO DETERIORATE OR OTHERWISE FAIL. ASTM C 754 INCLUDES TABULATIONS OF MAXIMUM FRAMING SPACING BASED ON THICKNESS AND ORIENTATION OF GYPSUM BOARD PANELS AND DEFLECTION AND LATERAL LOADING. SLIP -TYPE HEAD JOINTS: WHERE FRAMING EXTENDS TO OVERHEAD STRUCTURAL SUPPORTS, INSTALL TO PRODUCE JOINTS AT TOPS OF FRAMING . SYSTEMS THAT PREVENT AXIAL LOADING OF FINISHED ASSEMBLIES. DOOR OPENINGS: SCREW VERTICAL STUDS AT JAMBS TO JAMB ANCHOR CLIPS ON DOOR FRAMES; INSTALL RUNNER TRACK SECTION (FOR CRIPPLE STUDS) AT HEAD AND SECURE TO JAMB STUDS. FIRE -RESISTANCE -RATED PARTITIONS: INSTALL FRAMING TO COMPLY WITH FIRE -RESISTANCE -RATED ASSEMBLY INDICATED AND SUPPORT CLOSURES AND TO MAKE PARTITIONS CONTINUOUS FROM FLOOR TO UNDERSIDE OF SOLID STRUCTURE. INSTALLATION TOLERANCE: INSTALL EACH FRAMING MEMBER SO FASTENING SURFACES VARY NOT MORE THAN 1/8 INCH (3 MM) FROM THE PLANE FORMED BY FACES OF ADJACENT FRAMING. RESILIENT CHANNEL INSTALLATION: INSTALL RESILIENT CHANNELS FOR ACOUSTICAL WALLS TO PROVIDE SEPARATION BETWEEN METAL FRAMING AND GYPSUM WALLBOARD. DO NOT ALLOW ANY FRAMING, BLOCKING OR MECHANICAL, PLUMBING AND ELECTRICAL WORK TO BRIDGE BETWEEN FREE RESILIENT CHANNEL FLANGE AND WALL FRAMING. REVIEWED FOR CODE COMPLIANCE APPROVED W4833402 PERMIT SUBMITTAL 04.07.17 MAY 102011 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 0 2017 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 2-081 DENSITY IMPROVEMENTS W4833402 BUFFALO 04.07.17 3973 REGISTERED lob ARCHITECT fifIRIS I ED ' II CARLSON STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN BUFFALO DATE 04.07.17 CHECKED SUBTITLE MISCELLANEOUS SECTIONS AND DETAILS CURRENT REVISION W4833402 SYMBOLC R I G DATE 04.07.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE 2-81 DENSITY IMPROVEMENTS ARCHITECTURAL MASTER 2-81 BUILDING SHEET A5XX JOB NO. W1854280 COMP NO. DWG NO. 2-81-A5XX REVISION LIGHTS ON PHOTOELECTRIC CONTROL WITH MANUAL SWITCH OVERIDE, VIA TLC (EXEPT EMERGENCY FIXTURES) Nur 1111111..,111/..1011111.:111I./111111.,111r..111•10. i v Cf) w w LLT EX BY MATCHLINE, SEE SHEET 2E12 APPROVED DATE SYM REVISION r�► ! �l W,fr* ee A• �= itatlair111111 •iR12I 04 R12 3C 20 •� � © 43C aillizo210 k,lorpm-o; gairATFA 111 of A almOrri , fi�ll��� ► 3/9 89,a� R14 ► 89 ���11�1i0�f�' • IR. R �� �� Arta. d��►i���� Imo' WWI ►�■ re r rrm M✓I IVI, .nP LCP 2E3-2/R4,R5,R6,R7,R8,R9,R10 1"C, 7-3/C#20 BY APPROVED DATE RECORD DRAWING J#972197-00 2-81 & DENSITY IMPROVEMENTS W4833402 HGI/SDB SAZAN/EA 11.12.99 04.06.17 11' 2E3-2/11(R11,R12,R13,R14,R15) VIA LCP 2E3-2 LCP 2E3-2/R1.1,R12,R13,R14,R15 3/4"C, 5-3/C#20 M.E1 tff ® P •16 2E3 -2/11(R16) VIA LCP 2E3-2 REMOVAL VJARz�. O ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PP ROVED BY DEPT. DATE DRAWN B. BRITTAIN X1E3/9 LV LEGE \ D (SEE DRAWING 2 -81 -EO FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS) 3/C#20 LOW VOLTAGE WIRE IN CONDUIT, UNLESS OTHERWISE NOTED. INDOOR PHOTOCELL FOR DAYLIGHT CONTROL. USE G.E. RPSEN-IN. GE\E AL \OTES 1. UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THHN/THWN INSULATION, #12 AWG FOR POWER & #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 208/120V 48O/277V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASECENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL GRN/YEL (GREEN W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION/OUTLET BOXESS, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 7. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. EFE E\CE PAW! \GS 2-81-E505 "LIGHTING CONTROLS", LOW VOLTAGE WIRING DETAILS 2-81-2E10 LIGHTING CO\STRUCTIO\ \OTES DISCONNECT AND REMOVE 2x4, TYPE H, LIGHTING FIXTURES. LIGHTING FIXTURES SHALL BE REPLACED BY LED LIGHTING FIXTURES. RETAIN CIRCUITS, RELAYS, WIRING AND CONDUITS FOR THE NEW LIGHTING FIXTURE REPLACEMENTS. REFER -TO SHEET 2E10 FOR NEW LAYOUT. DISCONNECT AND REMOVE 2x4, TYPE A, HD LIGHTING FIXTURES. RETAIN CIRCUITS, RELAYS, WIRING AND CONDUITS FOR THE NEW LIGHTING FIXTURE REPLACEMENTS. REFER TO SHEET 2E10 FOR NEW LAYOUT. DISCONNECT AND REMOVE LOW VOLTAGE LIGHTING SWITCH, DIMMING SWITCH, OCCUPANCY SENSOR AND ASSOCIATED CONDUIT AND WIRING BACK TO NEAREST J -BOX. SAZAN GROUP 600 Stewart St., Ste 1400 W4833402 Seattle, Washington 98101 PERMIT SUBMITTAL 04.06.17 DATE SUBTITLE 10.30.97 CHECKED S. BERGSTROM 04.07.98 LIGHTING PLAN 0 Tel 206.267.1700 Fax 206.267.1701 SAZAN # 206-1777 ENGINEER B. BRITTAIN CHECKED S. BERGSTROM APPROVED L. COSTELLO APPROVED R. McNIESH TITLE 04.07.98 06.03.98 06.03.98 06.03.98 ELECTRICAL MASTER 2-81 & DENSITY IMPROVEMENTS BUILDING 02-081 COL. A -F/1-3 PLANT 2, WA. 2-81 BUILDING KEY PLAN SCALE: NIS 4 2 0 RECEIVED . C11irr OFl tUKINLA SCALE: (FEET) 1 /8"=1'-O" PERMIT CENTER CURRENT REVISION W4833402 SHEET SYMBOL A DATE 04.06.17 2EIOR JOB NO. J#972197-00 COMP NO. DWG NO. 2-81-2E1 OR r i%//if- 2E11 1 2E12 2E13 2-81 BUILDING KEY PLAN SCALE: NIS 4 2 0 RECEIVED . C11irr OFl tUKINLA SCALE: (FEET) 1 /8"=1'-O" PERMIT CENTER CURRENT REVISION W4833402 SHEET SYMBOL A DATE 04.06.17 2EIOR JOB NO. J#972197-00 COMP NO. DWG NO. 2-81-2E1 OR LIGHTS ON PHOTOELECTRIC CONTROL WITH MANUAL SWITCH OVERIDE, VIA 11LC (EXEPT EMERGENCY LIGHTS) A A h A A Apt 604.40, Ato. rirk Ammo nror .° A r Amplirdwar AMP' •47KY lgoo ji 441•04.410mtg Ad A Adlimo! :.61 Af',7 / re& ' • ifideir-AahAvarAm* Aar; "ligfercier "I'IgrurAPTV A Pr A177.. • .01:r Ire ifr://jfAr . e., 0 r 401r • • A "ir �p 4,000, i /1 �► J� j ��Y�Sierk. AiA0me4F-4. /% X1E3/9 1 A 10 .r ..v .r 10,R10 X1E3/9 6,R8 LCP 2E3-2/R17,R18,R19,R20,R27 3/4"C, (4)3/C#20 • A I.AirAA, 4,4 A , A/ A do ME-- 'Ar AP AIVAIMINVAIIIIIV at 10 AMP AffilIAMPAIEVer f/fi r' / �G/ Tow r:l rp V �' �' i ice, Oi . i 4 VA I A MIAMI Id, 4/ .4 i g'- n•rw, 2E3-2/12(R17,R18,R19,R20,R27) VIA LCP 2E3 2 1a1111 for,/t7404.367.227�,%■I�;' { ■vir►��A... di mr `wia MATCHLINE, SEE SHEET 2E13 (AD 100) w_ / ((2 LCP 2E3-2//R21,R22,R23,R24 A LCP 12E3�R22,R23,R24) -� 1 /2"C, (4)3/C#20 V PARTIAL PLA\ SCALE: 1 /8"=1'-0" VIEW O,R10 X1E3/9 REMOVAL REVISION APPROVED REVISION APPROVED RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 INSTALL DIMMERS 5259049 B 2-81 & DENSITY IMPROVEMENTS W4833402 SSH SAZAN/EA 7/19/07 04.06.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN B. BRITTAIN ,4734447, A I AN AQs4NOvs4L wire) LV LEGE\D (SEE DRAWING 2-81-E0 FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS) 3/C#20 LOW VOLTAGE WIRE IN CONDUIT, UNLESS OTHERWISE NOTED. GE\RAL \CTES 1. UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THHN/THWN INSULATION, #12 AWG FOR POWER & #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 208/120V 480/277V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASECENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL GRN/YEL (GREEN W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION/OUTLET BOXESS, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. ;EFERE\CE D AWI\GS 2-81-E505 "LIGHTING CONTROLS", LOW VOLTAGE W NG a ET S 2-81-2E11 LIGHTING CC\STUCTIO\ \CTES DISCONNECT AND REMOVE 2x4, TYPE H, LIGHTING FIXTURES. LIGHTING FIXTURES SHALL BE REPLACED BY LED LIGHTING FIXTURES. RETAIN CIRCUITS, RELAYS, WIRING AND CONDUITS FOR THE NEW LIGHTING FIXTURE REPLACEMENTS. REFER TO SHEET 2E11 FOR NEW LAYOUT. DISCONNECT AND REMOVE 2x4, TYPE AD, A, AND HD LIGHTING FIXTURES IN ENCLOSED OFFICES AS SHOWN. RETAIN CIRCUITS, RELAYS, WIRING AND CONDUITS FOR THE NEW LIGHTING FIXTURE REPLACEMENTS. REFER TO 2E11 FOR NEW LAYOUT. DISCONNECT AND REMOVE LOW VOLTAGE LIGHTING SWITCH, DIMMING SWITCH AND ASSOCIATED CONDUIT AND WIRING BACK TO NEAREST J -BOX. . RECEIVED CITY OF TUKWILA APR 1 0 2017 PERMIT CENTER AZAN GROUP 600 Stewart St., Ste 1400 W4833402 Seattle, Washington 98101 PERMIT SUBMITTAL 04.06.17 DATE 10.30.97 CHECKED S. BERGSTROM 04.07.98 SUBTITLE LIGHTING PLAN 9 Tel 206.267.1700 Fax 206.267.1701 SAZAN # 206-1777 2-81 BUILDING 4 2 0 8 12 16 20 IN IN SCALE: (FEET) 1/8". '-o" CURRENT REVISION W4833402 SYMBOL 3 DATE 04.06.17 ENGINEER B. BRITTAIN CHECKED S. BERGSTROM APPROVED L. COSTELL APPROVED R. McNIESH 04.07.98 06.03.98 06.03.98 06.03.98 TITLE ELECTRICAL MASTER 2-81 & DENSITY IMPROVEMENTS BUILDING 02-081 COL. F -L/1-3 PLANT 2, WA. SHEET 2E11R JOB NO. 5259049 COMP NO. DWG NO. 2-81-2E11R w LIGHTS ON PHOTOELECTRIC CONTROL VIA TLC (EXEPT EMERGENCY LIGHTS) W/ MANUAL SWITCH OVERIDE 6 LCP 2E3-3/R11,R12,R13,R14, R18 3/4"C, (5) 3/C#20 2E3-2/15(R11,R12,R13,R14,R18) VIA LCP 2E3-3 4,R7 AA ►''ii► iri`�lii//�"/L! Ag �`rlra_�T%%"� : ALM Mil �■ �► i � r�� ::I : . !WOW Imum I,//��fli////�%I/.%/� �/',.Ifs/�/ : �/// I throgr:417.17.1., 4 -7 ��' �'%•���stett_ _�.�.C�=����//,�.�.��/i://%►. 5,R g ��� �`'I ' = ',%FA �la riAprar 1%�a ����i�TYP ��t>,�n,�as�„�13�_0' 107Orre! NIE,_rr� rrri���tc�z,c / / '' U, ;« I/'I% lh '\ li17Iaus4 ?' li= ►�I�� [►i' -- --- op pr falW'il rip= WWI IN lier I am au iya um 1 Irdolirreirver.#2,„4:76frAnoir IrfiNvirrev#31 1111111/11.111111 rill -FATIOFfilli 1111,4ri�.� ar fel, Mid �iiiiar,.r�Mir iii�'r ►/ /, viiii�> ���i1 °, ' r jI�[�, � � ���� !Er- aii roarifOr,illigiiiiinilk, , , , . T ► I ' /► % I1 ��� • . 'n l���■moi r Sirii�,° ., �''� %� / / ��� 17,R15 ��1ill LCP 2E3 -2/R1 I / A AA afrir - pe leg Ilii i►� �-�m 17,R17 _� 17 ALM no .,15,R16,R17jiV•A� ' 'Apr • I , , AI 11 /' 1► ''. 'r1' 1. / �,R17 �`•a---��•� VII. imp ; & 2E3-31.— le. si NM 1) r roar pporoppini iiii hmealid in AaLTO AisaimdagrdiAdd Illintallirrall i'l EMU. 111111MIE I t p '�r pi �,•�/) j . 5R13'- 15R1 _17R17 —•• RA. ► / X1E3/13 X1E3/13 own I�� X1 E3/13 W i2i`!i► mr, ism LCP 2E3-2 74.11ERI.04/ ��� I �►�•�ussr • R37 20 . !41tW11••IA� �� E X1E3/13 7R17 17R17 Prd'�r 0r P I P ■ri 1_ ' • 4 m_ _ 117 R17 159 om=Ili►� vAlmiirs vr,l PAMPA ■ri/ZROM" CAIN �IMISr�� 4) r X 59 ► �l rfilEMMIIIMWMICIrr• MU al 1prvityprOprdpii A A A114 �1WIA Lar_ maim ,R1_EN � 7,R PO Ait/N A Alit //A/4t/ 3/I .�TE�� ri�I11 I►��RE 1 _—�"',�'�,.I,matILKI. mignizams am NC Ilereanal j�+ 2E 4 1 ■ 41 °rrAErall SIN ■�fiif�' 1 i�.ii/����.��'�_�—► � .� �h� t..x, f■� ��_ / / � AbliT ParritatirtSOM 0 I 1501 � � ► - / ► I � , / � , � .• . , . �� >�fl�����flIAl11!! ���■l1�1l�a1l�l�� �'� 1 114111rOgr ��/ ��I �� /►�� h� . r Ql' �t"�� 1 "Fr �► liiii / �• r ► r I • ► / ' Art. "1” fi►fi.� ra .1 / I ► IAh mirdirirmharawraerAdotioN4h;notawmtnag mottet4114 I: 4: Sp 4%1 grePrierjrrjoraPBPAPPAPPAPPI riFiriPOPPOPPrRIPPPrrforeriPIPPIr `/moilb° ForiamedmAmmd_rai.wlilorriooropiimorrli I . / . r r►! ,/INMI 111110/11111 I l���I.�.��1/f%�llr/ice./.1�1.,/I.1...�/1.��J� . � / � ► � WIAMEKINEWErapgrprakk �� .r.,'���� , ,-� I , j� i ; 'l:7► �.// /.��lr'I''C'``I�� . �1'I�.1%!' ,'` .J1il' I,� ,w-�; .y�S/ l/ .i//d1I<id� 3t� y� > %.1 A ii►/I rO i/fJ�i tli,1 /�V` ' ��,.. '' r t, �' 1, '`�V��r ` I' �r�� ' 1 / •' i oio /rW -Li '''''''' A4"' ' ' Adr- ■���-={f'��tr1 irF➢.13iil1... 1.�.�■ r atm I Agi) 3 C0 0 001 .411.1°' .141111Iiir I 11il / '00"141144om, 47;1010414440) II fr4r0.1,10,1°10111 00P401;1101 . 111010400 /0404 4 a ii r�/ /f i �� /lei � i ./► /r /I / / r100 10 , . , . 494';71:1 I / , Io' , r , I , .►,, , /P / P:FI AI r%/./r%`�%/%/r%/`�/.,� %/%e�%%/rtau/ /0110 � � / r / � iT r/1 °I4P* dp4411A igiedrSO" P' 1P110,00'/ 11 , 1 n'104d01( - 01 bot 440. 00 ' 4.04 4 r 00 111 1 44.4 44440100/AA442.14.4, . P4/0 AA00040r*rril OF rYAOIrlrA4 Od01 0000 rPI° .400 000 100 °Of, lei! 0 1411,1411161.114141 i I 1 / OVAir, .0. r AeT14 �Old"r �/ 1 44dB Ittvik_ 2E3 -2/13(R31 VIA LCP 2E3 MATCHLINE, SEE SHEET 2E10 2E3 -2/20(R37) VIA LCP 2E3 -2/R37 TYP. 2E12 E507 E3 11 (1ST FLOOR) LCP 2E3-3 LCP 2E3-2/R31,R32 1 /2"C,(2)3/C#20 AipgR37 2E12 E505 LI�I-TING CONTACTOR PANEL TO LV SWITCH ON WALL NEAR COL. E/6 (3 -WAY) 13(R25,R26,R28,R29) 2E3-2 LCP 2E3-2/R25,R26,R28,R29 1 "C, (4)3/C#20, (2)4/C#20 (O.S.) LC 2E3-2/R2,R3,R27,R37,R38,R39 1" , 6-3/C#20 W4833402 PERMIT SUBMITTAL 04.06.17 LEGE\J (SEE DRAWING 2 -81 -EO FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS) LV 3/C#20 LOW VOLTAGE WIRE IN CONDUIT, UNLESS OTHERWISE NOTED GE\ PAL \OTES 1. UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THHN/THWN INSULATION, #12 AWG FOR POWER & #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS "A" PHASE (LEFT BUS IN PANEL) "B" PHASE CENTER BUS IN PANEL) "C" PHASE (RIGHT BUS IN PANEL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND (GREEN 208/120V 480/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN GREEN GRN/YEL GRN/YEL W/ YELLOW TRACER) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION/OUTLET BOXESS, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 7. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. EFRE\ CE DAWI\GS 2-81-E505 "LIGHTING CONTROLS' , LOW VOLTAGE WIRING DETAILS 2-81-2E12 LIGHTING CO\STUCTO\ OTES DISCONNECT AND REMOVE 2x4, TYPE H, LIGHTING FIXTURES. LIGHTING FIXTURES SHALL BE REPLACED BY LED LIGHTING FIXTURES. RETAIN CIRCUITS, RELAYS, WIRING AND CONDUITS FOR THE NEW LIGHTING FIXTURE REPLACEMENTS. REFER TO SHEET 2E12 FOR NEW LAYOUT. DISCONNECT AND REMOVE 2x4, TYPE HD AND A LIGHTING FIXTURES IN ENCLOSED OFFICES AS SHOWN. RETAIN CIRCUITS, RELAYS, WIRING AND CONDUITS FOR THE NEW LIGHTING FIXTURE REPLACEMENTS. REFER TO 2E12 FOR NEW SPACE LAYOUT. DISCONNECT AND REMOVE LOW VOLTAGE LIGHTING SWITCH, DIMMING SWITCH AND ASSOCIATED CONDUIT AND WIRING BACK TO NEAREST J -BOX. RECEIVED CITY OF TUKWILA APR 10 2017 PERMIT CENT AZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN # 206-1777 2-81 BUILDING KEY PLAN SCALE: NTS 3- 3(R , 5 VIA LCP 2E3-2/R2,R3 PARTIAL PLA SCALE: 1 /8"= 1 '-0" \ VIEW APplir 104 �TA1�° QUIR�o REMOVAL REVISION APPROVED REVISION APPROVED RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 A BTS RELOCATION 1001594739 STEWART 3.18.05 B 2-81 & DENSITY IMPROVEMENTS W4833402 SAZAN/EA 04.06.17 gLBOE/NG ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PPROVED BY DEPT. DATE DRAWN B. BRITTAIN CHECKED S. BERGSTROM ENGINEER B. BRITTAIN CHECKED S. BERGSTROM DATE 10.30.97 04.07.98 SUBTITLE LIGHTING PLAN 4 2 0 4 8 12 16 20 SCALE: (FEET) 1 /8"=1'-0" CURRENT REVISION W4833402 SHEET APPROVED L. COSTELLO APPROVED R. McNIESH 04.07.98 06.03.98 06.03.98 TITLE 2-81 & DENSITY IMPROVEMENTS 06.03.98 ELECTRICAL MASTER. BUILDING 02-081 COL. A -F/3-8 SYMBOL 2E12R JOB NO. PLANT 2, WA DWG NO. 1001594739 DATE 04.06.17 COMP NO. 2-81-2E12R 2E10 2E11 / / / 2E12 2E13 HI 2-81 BUILDING KEY PLAN SCALE: NTS 3- 3(R , 5 VIA LCP 2E3-2/R2,R3 PARTIAL PLA SCALE: 1 /8"= 1 '-0" \ VIEW APplir 104 �TA1�° QUIR�o REMOVAL REVISION APPROVED REVISION APPROVED RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 A BTS RELOCATION 1001594739 STEWART 3.18.05 B 2-81 & DENSITY IMPROVEMENTS W4833402 SAZAN/EA 04.06.17 gLBOE/NG ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PPROVED BY DEPT. DATE DRAWN B. BRITTAIN CHECKED S. BERGSTROM ENGINEER B. BRITTAIN CHECKED S. BERGSTROM DATE 10.30.97 04.07.98 SUBTITLE LIGHTING PLAN 4 2 0 4 8 12 16 20 SCALE: (FEET) 1 /8"=1'-0" CURRENT REVISION W4833402 SHEET APPROVED L. COSTELLO APPROVED R. McNIESH 04.07.98 06.03.98 06.03.98 TITLE 2-81 & DENSITY IMPROVEMENTS 06.03.98 ELECTRICAL MASTER. BUILDING 02-081 COL. A -F/3-8 SYMBOL 2E12R JOB NO. PLANT 2, WA DWG NO. 1001594739 DATE 04.06.17 COMP NO. 2-81-2E12R 23.1 18.8 '7. SWITCHED TOGETHER )(In/124R' ,TRICA 21 DA22 2E3—•/25(R5,R6) 27(R7 R8) X1E3/12 21DA20 X1E3/12 X1E3/1 LCP 2 1/2"C E3-3/R6,R7,R8 (3) 3/C#20 w X1E3/12 LVR1d XkE3/12 gii E X1E3/12 VAU T 50 22119 EQUIPMENT RC OM 25,R5 29,R10 21 A19 2E— 9 '-,•1 VIA3LCR — LCP 2E3-3/R5,R9,R1 1/2"C, (3) 3/C#20 X1E3/12 STAI R 21DB1S X1E3/12 X1 E3/12— (2) 3/C#20 7-8.0 R1 Dr (WTF) SEE 2E11 PARTIAL PLA\ VIEW SCALE: 1/8"=1'-0" DA.L DB.9 REMOVAL SYM REVISION BY APPROVED DATE SYM REVISION APPROVED RECORD DRAWING J#972197-00 HGI/SDB 7.28.00 2-81 & DENSITY IMPROVEMENTS W4833402 04.06.17 M.E7:M"® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN B. BRITTAIN CHECKED S. BERGSTROM ENGINEER B. BRITTAIN CHECKED S. BERGSTROM DATE 10.30.97 04.07.98 04.07.98 06.03.98 APPROVED L. COSTELLO 06.03.98 APPROVED R. McNIESH 06.03.98 LV LEGE\D (SEE DRAWING 2-80—E1 FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS) 3/C#20 LOW VOLTAGE WIRE IN CONDUIT, UNLESS OTHERWISE NOTED GE\FAL \OTES 1 UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THHN/THWN INSULATION, #12 AWG FOR POWER & #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 208/120V 480/277V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL GRN/YEL (GREEN W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG—ON CIRCUIT BREAKERS ON BUSWAYS. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION/OUTLET BOXESS, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 7. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. EFE�E\CE DAWI\GS 2-81—E505 "LIGHTING CONTROLS", LOW VOLTAGE IN D ILS 2-80-2E15 LIGHTING CO\S-RUCTIO\ \OTES DISCONNECT AND REMOVE 2x4, TYPE H, LIGHTING FIXTURES. LIGHTING FIXTURES SHALL BE REPLACED BY LED LIGHTING FIXTURES. RETAIN CIRCUITS, RELAYS, WIRING AND CONDUITS FOR THE NEW LIGHTING FIXTURE REPLACEMENTS. REFER TO SHEET 2E15 FOR NEW LAYOUT. RECEIVED CITY OF TUKWILA APR 10 2017 PERMIT CENTER :;A7A,N 17 9O 0 2E15 A 2E11 GROUP 2-81 BLDG. 600 Stewart St., Ste 1400 W4833402 Seattle, Washington 98101 PERMIT SUBMITTAL 04.06.17 SUBTITLE TITLE ELECTRICAL MASTER Tel 206267.1700 Fax 206.267.1701 SAZAN # 206-1777 LIGHTING PLAN Ap 2-81 & DENSITY IMPROVEMENT BUILDING 02-080 COL. K—P/1-3 PLANT 2, WA. 2 80 BLDG. KEY PLAN scALE: NTS. 4 2 0 4 (2) 8 12 16 20 SCALE: (FEET) 1 /8"= CURRENT REVISION W4833402A SHEET SYMBOL 2E15R DATE 04.06.17 JOB NO. J#972197-00 COMP NO. DWG NO. 2-80-2E15R LIGHTS ON PHOTOELECTRIC CONTROL WITH MANUAL SWITCH OVERIDE, VIA TLC (EXEPT EMERGENCY FIXTURES) ------------------------------------------- � � "' r ''� I% 111 � 01111'21"i'llliK1111111141Fm"W-101 1_..,=.r..•...,___ ,.,—.�..,,.r_I:;---,:--+►► �, 1� � ,_� F a_I/' �1����9■ ■Llr��/' �� '��91111 �"-'�'� 11, ���Irai�u►;� �1. ;Lvlii �ir���l� ( ���i�i��1����' �� L1 �a�� • �+ `/1 4 1►�•►'\• /'�a, / � /1 n:� )ut+.r��� �� • P91• 0 •► I �I I 1 ,� r '' 1. h■:,1 `�. � ; �,11■1■II111 1 \h �.�►JIIIII�III,/� _ 1'�` 1 ����Jl nial,11-,�illl��■I�\�� � 1 � l!�.r`�i�� II,111 � l�ll �f111 Fir �l�l!1 I ■1!1 I■� 'SI 111 1�111�1 �I "l•el1�G" i�l�il`'� 11 X111\t 1 �.�v�//1 ■IU�r.. `.`r'�1/ 1 _ III�..i■1�I-' +•� I INIONNielli _Fill �■■i rI 1I i l i�lilii■�i■1■■i lil iii ��l�■�Iill �� 1��� �.� ����i�ubuii i 11111• . 2,R• • • �/.���• I ,--�II I�� II��1�'�I I�� �1� ,1;: ��� 4, �... njIon 1. :,��I ■�� ., • : •,_ �� .� I■1■I [:�►'�.! _�•�ia IIIIIIII��! ! Iro!�a, ii11■ ,�• �l �1!ro■I C// . i1gj1 I!!!iiiIRCIIII1C,. Jr all 11-701,* 1 11 'MIIF. ; • 1 ' f Lilo iii r srt�� 1 •�� �, �rt �111 �I� -.I11 IIII / -Ii 1I■ MIIit N i ��►,�111111;16.1141FE: 1 I:�eai 1111 i r�I.l,►11■1il��IIII■�.111■■■II�•a��a�-(I 11�- �!�'r% ii�:/�1�1��✓�ILN�111_!!!�✓ 11■i� IligmiliMilli.111.961 ■�i�■■� ■■■��� ' ������I�� •�■■��■ ' I.��I�l■■■il I■.i.1�/��■I ■ I...I.il1.'s II■.■�Il���..I 14 �._ �. �. •�n..��_i�erurj�...1e__W j:�n �.�.iY�!t T.1�.�i-Y1:J:�1�--WN ■. l�/U.,•�.1�--I1•:G71.��--/1la-i��-l.��,i�tI-�W V ��If7:7:1•Ilial•t\�11��--1!!1i[i�.�.I��•11►N��' ► Irl,IrI!�iIIiIN1 III II R6 ira. ■111A Il .l 01111 ■ ■Ilidi\ �► i��ll■ ali►� �i v 111 fTi /r f �+II�i:��,:.��..>~•,l. � ) I r•�-Lw_!° •1■ ■1 `���,.� ��.+i�•1p.�' 11■ ■II �f��.�1...��� 1■ ■11 b=w' •���• 11■ilii ►�!►;�i:;', •; �1�'�' ��JP' ��. I�► si , ; i) ���•1�;�11 ��.��, psi �I':���.I.I��:-r�I ailliMEI '1• ii�licl.���yl'� CF�>✓��I�i l� I�ii���ii%��` o■ ■�� �11I �I� ill 1/�I�"_•J)�•• �o! _ ••JI I • • ���1 � I '�n��iiuuiiir;i■�■ !u!1uruIIuNi' .' la■ II �� I:;;lilill j I:�i1111110 imm • o _r '�4^" .� w�. �� , '�.� �- ww _w. A��.Ir� qs ■_� �■ �, .��-� I NoutemimEtriviettile-mmuillinin4 _ �il.L m111.4■1111mi i.e iI■I lir■flies■�1111a�a�i�l■■wiral%Illilli� II11; 1[�i■;�i��ll■.IIIl11u1/.■�I111i.�i�lllvfw,. ■ .��,�. ( Ir■il►�I■■■L91;i!?' ` II!P o1■ Mil' 1111111110011112=11 I'i�. g ' § Immo • ' r■■■L'ist'diII • t iI;�■■h�di■■i ��i■■I►::■lI■■ 1111E7111111111Miniiiinnit r z 31 �1J1■111r `IU! n 1i 11i ■■`iiUII Ili IiVliiiIilhilIIiiE! ® IKI !il r !!!J!!!!!i EfiiiiiiiiiiIIIIIII! -/—,,----����.� l T ------■- 1� ��■ 1I )u..I "■.r1MP I-1 �' n,.r_i� �,•:.w■ ■I �'!.,�\ 'I �1 1 ��_�1 -■1 1 1 .■ • = C r .1► �; .1/ � t!Ia III hitt :l!1 il‘fid111141,41111 E1,) ill _ .�I I■/ .,.��, I� • -.► I.I.I.• 1.1►_.._ II'...J 1//./�:�.�/ 1./l ilk ■���11�1M�i`I Illr/ux11.1r/�i�iiseamomlonkiihnhamilmit-Aik! ,mi Il.•■II 1 • Ir—�_ iI I■ .�.tLV�,• r A % j� r �: ,. 1 r ,� 111111111;11111111111111111inimg; �ww_w"...... ..... i 1 a4mil,� ,� ,.� ■■■II'o�rs•�.��/� �� I�,�� 1_-�_� &����l1 �►� ��� hs�Q��fi'i/� �•%::!A� 1;���rsr,-711��'��/��r17 1 �./ r rAli �II �1i�Eltilfii l �'llrlrl ��'ri�1'(1■l�r� !! [��si�i simplailli►�a11� {1 18. ,� ,;�� — -;;•iri,..•1°-mimi.. �'�11 �� � � Ili i �I• IM�'!� I� ffr�rl_Iisnewe111 eiRro� � ri AirillSirc !: R IIIIM7��reFl `� ����.' �� 1 ....� l�1 .... SII MINK I....' ��►�,IR , �.�� •���II II li MATCHLINE, SEE SHEET 2E12 2E3-2/2(R6),18(R36) VIA LCP 2E3-2/R6,R36 LCP 2E3-2/R4,R5,R6,R7,R8,R9,R10 1 "C, 7-3/C#20 PARTIAL PLA\ VI SCALE: 1/8"=1'-0" REVISION APPROVED REVISION APPROVED - RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 2-81 Sc DENSITY IMPROVEMENTS W4833402 04.06.17 Q� BOE/NGS p-- ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE 1E3/9 DRAWN B. BRITTAIN W4833402 PERMIT SUBMITTAL 04.06.17 LEGE\D (SEE DRAWING 2-81—E0 FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS) LV 3/C#20 LOW VOLTAGE WIRE IN CONDUIT, UNLESS OTHERWISE NOTED. $Dim INDOOR PHOTOCELL FOR DAYLIGHT CONTROL. USE G.E. RPSEN—IN. WALL DIMMING SWITCH WITH INTEGRAL OCCUPANCY SENSOR GE \RAL \OTES 1. UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THHN/THWN INSULATION, #12 AWG FOR POWER & #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 208/120V 480/277V "A" PHASE LEFT BUS IN PANEL) BLACK BROWN "B" PHASE CENTER BUS IN PANEL) RED ORANGE "C" PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL GRN/YEL (GREEN W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG—ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION/OUTLET BOXESS, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 7. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. 'EFHE\C IAWI\GS 2-81—E505 "LIGHTING CONTROLS", LOW VOLTAGE WIRING DETAILS 2-81—E500 2-81—E500a LIGHTING FIXTURE SCHEDULE LIGHTING FIXTURE SCHEDULE CO\STUCTIC \ \OTES PROVIDE LED LIGHTING FIXTURES. REFER TO LIGHTING FIXTURE SCHEDULE ON E500 AND E500a. UTILIZE EXISTING CONDUITS AND CONDUCTORS FOR LED LIGHTING FIXTURES. REUSE EXISTING LIGHTING CIRCUITS, RELAYS, AND CONTROLS. PROVIDE WALL MOUNTED DIMMING SWITCH WITH INTEGRAL OCCUPANCY SENSOR AND ASSOCIATED WIRING AND CONDUITS. MANUFACTURER: LUTRON—MS—Z101—WH RECEIVED CITY OF TUKWILA APR 10 2017 PERMIT CENTER AZAN GROUP \ 600 Stewart St., Ste 1400 Seattle, Washington 98101 DATE 10.30.97 SUBTITLE CHECKED S. BERGSTROM ENGINEER B. BRITTAIN CHECKED S. BERGSTROM APPROVED L. COSTELLO APPROVED R. McNIESH 04.07.98 04.07.98 TITLE Tel 206.267.1700 Fax 206.267.1701 SAZAN # 206-1777 LIGHTING PLAN 4Roile 2-81 & DENSITY IMPROVEMENTS A 2-81 BUILDING KEY PLAN SCALE: NTS 4 2 0 8 12 16 20 III 11111111111111111 ■ ■;{� SCALE: (FEET) 1 /8"=1'— CURRENT REVISION W4833402 SYMBOL A DATE ,, 04.06.17 06.03.98 06.03.98 BUILDING 02-081 COMP NO. 06.03.98 ELECTRICAL MASTER COL. A—F/1-3 PLANT 2, WA DWG NO. /�/�%%iii &/2E11 2E13 2E12 2-81 BUILDING KEY PLAN SCALE: NTS 4 2 0 8 12 16 20 III 11111111111111111 ■ ■;{� SCALE: (FEET) 1 /8"=1'— CURRENT REVISION W4833402 SYMBOL A DATE ,, 04.06.17 06.03.98 06.03.98 BUILDING 02-081 COMP NO. 06.03.98 ELECTRICAL MASTER COL. A—F/1-3 PLANT 2, WA DWG NO. X1 E3 6 LCP 2E3-2/R17,R18,R19,R20, 3/4"C, (4)3/C#20 2E3-2/12(R17,R18,R19,R20,R VIA LCP 2E3 2 LIGHTS ON PHOTOELECTRIC CONTROL WITH MANUAL SWITCH OVERIDE, VIA 11LC (EXEPT EMERGENCY LIGHTS) 0./���� 1/�I ��V 1/11■ ■V �� 1/111 %V Vh� ■1/11 �� Vh�V�� V�� X01:211:101 ■■111kil Le kibgbilLII SMI SLI gh�■■ligh■■1r111■■W hE■ilhil iklill■■t EI � ll■I1_IM NsOmn 1 V • PMEMUMBlegiiMunairgiuminti •_ v • S £_ r •b1. —•—�_ ��.■�■_�_Il�i� _I���1 _�1 �,� eiiiiiillialkillilliqi /I_ _--�� _1I #�`��� � 1 � P' h �� t ,''" II � ,��i/ ��r II � 1Ii1ONill __� __-a��n£,�f�p c� ���ilpigt� pry W, rN� �e�..�-�i A Rl 061 11.�►0 1111.I�•`'� � Ii f '►d ( f'' ;" � L. ��-,�... I � 1 . • j , .� .�;�... i-�! �- , I, I d1�, EW 91■l AA ,1l.4� �IIm CIP EmOrmil■11m ■oth r itmaa111 �, I i�:...,._ I1 , - , ► ►1i 1 INICV 1111■ '11�11��r.1-03111`1111�1.���r � c OdgEl r.ira,,�lll�� I� I �I� 1����:_ :�u��� Ip4tml,1/Fiil ��oil���� 1/' `�i��;.i� 1►`viiiiii 1/' `�L��6- ili�� 1/`�/���ii--ii�� 1�1 OPIAMU. .�11��• .1,. Orr, JI.,IIS. ,ll ,�, 11111 .:.Jlllii ,� . �, III .sig. l� III ■I �`� �s�t t■ SII '��;,;. � �� "�,! :►�- ��±.� 1 � -�', ��IIS .`�'1 � N`�'I! °,� ;'r i i .�l'►�i'II°�1, �.:► "' -,���' � �4�� � v���t& `' 1 II ■u ■itl I■�■ib �1 111■I■ idai 1 i ■u% I ��r1iim.UI■ I II ■11■isiI IMM■ 1 ■rl 1���11NE 11111111211_511.111 - ■���1� I�� =I��■�r� lr■ �� ��(I tiollialoll . _ , � • I �I �" '• i � '�� � "' II I�� 1: � : � , 1��11 � - �l i�;��� j it � �Atli,► �i`I� ., ..� E�I�i� A�v1ril -�!�i- i � II■ ,�11 1111 �P , `to I�� li ---�I 1` , I 1111 lit...�i■Ir�. ";•��1 i1�1�,.�1,�� �� .�`. ,� , � ��, ..�,. � ■i �� . �,,,ll III ��, • I/!��•�i1111i ��,..�, . , I��► i 1 16 IL`i� ilib.;a�1� I■a�lgaillll► Alilii��n►��Cl6 ,r>•.�iul���'lll gl\�i I■I�r� ►��/J �� I � ►iJl.l 111 i/nl•rI��1■� �Itl►wi�aa� a o 1tv�t�>w.. klilli0 _��1��1��■� w ��aif_nwll wll�w►1 i 1/��IN•us���ll ,]�e�', �i�1C� �L�i� 1 ���i��■�n�'.,,, .. �i� I�.l�i,�:��il l `ll��, '��a 44��1!�4., gillIl�u' ��1�111 �GIII11■� .:.111,t�1�s1■� ,.;�► H 11� !�_ R. I�.�� - , ;x011 ��� 111 cf =v��� 111 �,..'�_li1 �r:.�il `lu I �� _1111 ii°4- IL►t 111.. . • 1 I �•.,,�� �J I ►��/�`►.� L.���Iw I" ,,' ���J■I =' .''J ■■■!it��• I�1h��l� /�rlr`'T �Ik •� lI„I • I�a`•� ara! �• �' 1 �`�JIiiiiiiiaii z ■i�Mi��■I■��■ w.,r� 11111■ Il11ili1 ■•..• �;— . ,.�• —;--1 w� I, :� 1-O � • .•_ __ ��—� • .• • • ' . 1 1 .fI, • ' w ' ,,''I. 111.��.«� �� il,/�, .�,1 -� (� .■ 1/, �:,�•.III Iii +�• /r Il1111 � +11► .I1 I\ ��II1�11���� �� I ��► �'-1- ��.I_I-_ � i� -■��::� � � � I I � `` ��' •'�tllllt..II�i,lr.1, ,_:ji■INI till t■ it I �ilI I_III_� �I11111111` !Il�1'�I,I.r• ; '� Q4� ■`�Ir% ,I h�1�j� / , aIG1�.ir , \.JI���1`n�•�.•ll �• ..�� •� , .• � 1111 � ,\• ■• �• • / �t • / �1. / - �i �F♦ �+� �� � / • •• r • NI � �ea! 1�"Ii. • \. ► 1 '�/n�• 8 `� •��II I,i • � �I � ✓i � 1.1 � �1 �!! II Igminvmem 111 �M,,.. � SII■I � �, !!, I:11,- � .l11 � I��11 i�,.. . � i�l X11 �'rg ••• ��`�•��� ` �F��`�•�� !J/�1!��. 1��_., II■�t>_w I 1�+1rr/II ari ill • • �► • • �� • - �J� ■ �� ..�_� 1�=���liii �� ��.�liiiii 11 !��■ 111 ��d (iii■I ,:���i'��'`i� lii911■IPP! 1 ' ■Y����ifi ��, .�i1 lige'_., „�`�;�I _ �;lii�i't_vv11!,1 I . ` lr alli�� �,£I , ar 111 _ ._ rhos" 1�''�I��4/�II_� ■� �■�! _!!V.► 11 _. k�i/AII� �It�!lhi�7-� 4,1�►ill■ I ,u• .�`u �I �.�� � I tell�r>'.,I_. ..r► --/I I". ,`' '' I ■�. I� ��` �+,rn.:�� ■■ ''I _-. �s� I� +� �.r,. -.cw�� 1'N�I■11 i R�iimiliE_� 1 Jffilmil fill �1►mnimil �A 1�«i�i � �7•__— ---��'___ _ ��%.— �.r►�` •iII t/ __. ��° `�' 6 ' : i _NAL_Eilifiallr: 11 visiom li•� _ i ,■lII•� : 1: ilii le�•�■S■ � yrUlii!1rii!iIi1IliiIIiimiiiiiiiiiit---0" igo,R NINo,^ammoic.;la. =-11 d a i®6 /■i_��.w qtr—�:. wilmEnnifil • /`��d■I R — ;�11 ■ r-_, k MiS 7 ,R , 19 v. 41110 iECE:�� ' ��7.�1 l ! I, iI /iT:� iii 11ik1�■■ - ; - �. A � � �£ ,.,:. }F � �� :r � �� �---�.i, .�, } rales �.� 23 �: R18 E � f , � E 11/Mill 38 !1iJI9hIh&iILTI IIIIIMIIIIIII4 4 i,�, ; ., I I ��r _:•� �,�!!'� mmo i i 1 II �o :�■�:� 4,1 2 1} ,; ,a , ; �' v�I%\,' x I�■�1�, :� �R1',1� 38 M tln ��� �� �� %!�. ■ITH/Ir I�l;.�h��■ , /:■�,:;�,.r.r,■iIO►� l %r „ : 5j �� i �I •�' 4 �, �,� .i'..3 . •sl 011111:' II, IIIII1!� , 'Niru' lii//I■ nSx,1 ►'1� .I �'� � � � £ :. t£4 1 /� '� ►�.�WM-- --w r I� • ' � _:2.^�.'ll/���� /►�����4R1.VA!k r mi®�3 ( I��1 � �� a► �, � , ,� ice• �� 1- �'% __ - �� AMa Wml\ MY /AD �100\ � 2E3-2/14(1R21,R22,R23,R24) VIA LCP 2E3-2 HIrR'"I X1E3/9 10,R10 ATCHLINE, SEE SHEET 2E13 LCP 1/2"CE (4)3/C#2022,R23,R24 .SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 A INSTALL DIMMERS 5259049 SSH CAS 7/19/07 B 2-81 & DENSITY IMPROVEMENTS W4833402 SAZAN/EA 04.06.17 ?1,BOE/A/P — B. Ar LV LEGE \D (SEE DRAWING 2 -81 -EO FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS) 3/C#20 LOW VOLTAGE WIRE IN CONDUIT, UNLESS OTHERWISE NOTED. $Dlm WALL DIMMING SWITCH WITH INTEGRAL OS OCCUPANCY SENSOR GE\E�AL \OTES 1. UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THHN/THWN INSULATION, #12 AWG FOR POWER & #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 208/120V 480/277V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL GRN/YEL (GREEN W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG -ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION/OUTLET BOXESS, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 7. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. EFE�E\CE liRAWI\GS 2-81-E505 "LIGHTING CONTROLS", LOW VOLTAGE W: G 1 2-81-E500 LIGHTING FIXTURE SCHEDULE 2-81-E500a LIGHTING FIXTURE SCHEDULE CO\STUCTI O\ OYES PROVIDE LED LIGHTING FIXTURES. REFER TO LIGHTING FIXTURE SCHEDULE ON E500 AND E500a. UTILIZE EXISTING CONDUITS AND CONDUCTORS FOR LED LIGHTING FIXTURES. REUSE EXISTING LIGHTING CIRCUITS, RELAYS, AND CONTROLS. PROVIDE WALL MOUNTED DIMMING SWITCH WITH INTEGRAL OCCUPANCY SENSOR AND ASSOCIATED WIRING AND CONDUITS. MANUFACTURER: LUTRON-MS-Z101-WH PROVIDE 3 -WAY WIRELESS LIGHTING CONTROL. MANUFACTURER: LUTRON-PJ2-3BRL-GWH-L01 RECEIVED CITY OF TUKWILA APR 10 2017 SA/AN .. MIT.ICENTER GROUP 600 Stewart St., Ste 1400 W4833402 Seattle, Washington 98101 PERMIT SUBMITTAL 04.06.17 Tel 206.267.1700 Fax 206.267.1701 AZAN # 206-1777 �ET.M+KRge. "'a ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN B. BRITTAIN CHECKED S. BERGSTROM ENGINEER B. BRITTAIN CHECKED S. BERGSTROM APPROVED DATE 10.30.97 04.07.98 04.07.98 06.03.98 L. COSTELL 06.03.98 APPROVED R. McNIESH 06.03.98 SUBTITLE TITLE ELECTRICAL MASTER LIGHTING PLAN 2-81 & DENSITY IMPROVEMENTS BUILDING 02-081 COL. F -L/1-3 2-81 BUILDING KEY PLAN Scat m 4 2 0 4 8 12. 16 20 SCALE: (FEET) 1 /8"=1 '-0" PLANT 2, WA CURRENT REVISION W4833402 SYMBOL 3 DATE 04.06.17 SHEET 2E11 JOB NO. 5259049 COMP NO. DWG NO. 2-81-2E11 LIGHTS ON PHOTOELECTRIC CONTROL VIA TLC (EXEPT EMERGENCY LIGHTS) W MANUAL SWITCH OVERIDE 2,R• & LCP 2E3-3/R11,R12,R13,R14, R18 3/4"C, (5) 3/C#20 2E3-2/15(R11,R12,R13,R14,R18) VIA LCP 2E3-3 4, R7 � zLL, 2 V) I���IS�111� I/■■11 7 �!� ' E. "'I 1) Iha t 111111191‘111 Emu i'zip2=0)fframmil 1110111111211 MI aummymo r Lai 0 I MISFILIPMENIEREN miciiikai—iiniiii 1e �I-.glegme.10- ■..illo �m1i► �i 'm tall= IIIIM 11111F.I‘T-6.6 11121fillt ritillIFILIIII MIN 11111 11111 raILI.■ 17,R17 ►��,�,R17 ‘�YMVP'aa IA 1MI 111111Nr13111 tK 1� iim 111111:11111111111111111in_.Y�� .aY it Mlll�i"17,R17 .7,R17 —M' 17,R171le 1111111111111111 €f {m gm YPIINI; gamma VAIN El i rigratak",1111wAhms ,---.. .....m... 111111111111111 lrullIllEEMIMI AEI ,..R17 ���� 1.:51.1...igialimi sg. ism kgii Am"„ • , um ENE �17 Want" R17 II MI LIM Di /ojipawasiongiAa►old . i►. T�ii mi ial NI __, illip:411111!_■:111,1 1�M!MIN , 11 ►'�jli�l��� �1!' 1 fir` ? ► .�Ill�.��.11.��iummi I> lilr�.e nsidag �t.�REP �u�� 1111 ■�1L'u�l�.i:�tIt�l.���ra�•�_{x 1 1111 1 11 111.��1►711���a1�1��■��������i�� u n 1/_�F'�il��i�� IIIA ■II■ MATCHLINE, SEE SHEET 2E10 �1l11►�1111 �� ,�'. ‘..111. ria urAMMi ----.#1110111110. 2E3 -2/R1 �J -��'mi .CP 2E3 I, ,' I • • • • 20. • 111111 11111111RUE- - 2E3 -2/20(R37) VIA LCP 2E3 -2/R37 X1E3/13 LCP 2E3-2 b TYP. 2E12 E507 X1 E3 11 (1ST FLOOR) (A\ LCP 2E3-3 LCP 2E3-2/R31,R32 1 /2"C,(2)3/C#20 2E12 E505 LIG ING CONTACTOR PANEL TO LV SWITCH ON WALL NEAR COL. E/6 (3—WAY) 13 . ,-•--,... �.._:�•.----. �,--, �I ■iii•a•(iuuii �:�.1r�Il�Iu11ii.i ill�ii u � z ta„ 1 E3��' iil ii7 i`7�� � 1 �ji� �� i II �� �;� �I G 13 ii �© ii �► m ii � .1 ilAi1 u != is. tp • iC•�� 111 ■u■ 1,11111111111111111111 1��1 '�1� ._: �1� 1/j r��., 6 •� n n n } 3 Amer" e ' •IiIliJi'i!!IIiL1ii() i�� •�' '�• •�' I+s4e} JJif• �,�, �hill !UllPhIIlhlllI4lU 04 IL -.4,w gismo- •fiwo. 'moor' 'mow 'moor” "N•www- 11,00"' .ammem Irma mom is • mammin Ellie 18'mui ..► il,�..IIi41IiIhiIi.'.� . a E44�.;.. �,�1��::�_ Altal11111.tribillarbilar% ����1® ���11�11� !a1..���►I�i ��n► � _ ��.� ►moi%SLI 11� ISI I Al im' 'ri ug!.i' I.�I/►11�—•�--�--� 1:,R3;,IF ,��-'�i�l'ill! � 18,R + • 111111111�,.. 2 ► . f � I �' •tr00-.4" � ���,,�, It III !�_ _ _ /11111111141111° 1r SII ��.®�('�1 '■'_' ~�• . 1$ R3 t�l�:"-..r 3,R (;,� �� 20 R37 �i►_�:�!� • 01� �.� R;7 i■ .� ip,iel � — \/I�� 11 _-- .1 �ie�lh, E !put .1II 111/!�,� : ' i i 18 R 6 `� �,I •' 0 R 7 I io i . ��i, ISI IIi iiiiiiiii dit 17IIIl�J�21i �� Ir1 anim '' "Ainn112 il tilt%M'�!'—�■• •/�:�!/`-rhIllbii. 1311111.1 I 3. 2E3-2/R2,R3,R27,R37,R38,R39 -3/C#20 PARTIAL PLA\ SCALE: 1 /8"=1'-0" VIEW REVISION RECORD DRAWING J#972197-00 BY HGI/SDB APPROVED DATE 11.12.99 SYM REVISION BY APPROVED 2E3 -2/3(R2), 5(R3) VIA LCP 2E3-2/R2,R3 DATE BTS RELOCATION 1001594739 STEWART 3.18.05 2-81 & DENSITY IMPROVEMENTS W4833402 SAZAN/EA 04.06.17 BOE/NC° 6'— ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN B. BRITTAIN DATE 10.30.97 CHECKED S. BERGSTROM ENGINEER B. BRITTAIN CHECKED S. BERGSTROM APPROVED L. COSTELLO APPROVED R. McNIESH 04.07.98 04.07.98 06.03.98 06.03.98 06.03.98 833402 PERMIT SUBMITTAL 04.06.17 LV LEGE \J (SEE DRAWING 2-81—E0 FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS) 3/C#20 LOW VOLTAGE WIRE IN CONDUIT, UNLESS 0-IER►ISE OT os OCCUPANCY SENSOR $Dim WALL DIMMING SWITCH WITH INTEGRAL OS OCCUPANCY SENSOR $ M 5—BUTTON MASTER SWITCH WALL STATION GRAFIK EYE LIGHTING CONTROL UNIT IR INFRARED TRANSMITTER/RECEIVER PAIR — PARTITION SENSOR 'E\E SAL \OTES 1. UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THHN/THWN INSULATION, #12 AWG FOR POWER & #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS "A" PHASE LEFT BUS IN PANEL) "B" PHASE CENTER BUS IN PANEL) "C" PHASE RIGHT BUS IN PANEL) NEUTRAL EQUIPMENT GROUND ISOLATED GROUND (GREEN 208/120V 480/277V BLACK BROWN RED ORANGE BLUE YELLOW WHITE GRAY GREEN GREEN GRN/YEL GRN/YEL W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG—ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION/OUTLET BOXESS, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 7. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON. COMPLETION OF JOB. —EFE�E\CE DAWI\GS 2-81—E505 'LIGHTING CONTROLS', LOW VOLTAGE WIRING DETAILS 2-81—E500 LIGHTING FIXTURE SCHEDULE 2-81—E500a LIGHTING FIXTURE SCHEDULE CO\STRUCTIO \ \ OTES PROVIDE LED LIGHTING FIXTURES. REFER TO LIGHTING FIXTURE SCHEDULE ON E500 AND E500a. UTILIZE EXISTING CONDUITS AND CONDUCTORS FOR LED LIGHTING FIXTURES. REUSE EXISTING LIGHTING CIRCUITS, RELAYS, AND CONTROLS. PROVIDE WALL MOUNTED DIMMING SWITCH WITH INTEGRAL OCCUPANCY SENSOR AND ASSOCIATED WIRING AND CONDUITS. MANUFACTURER: LUTRON—MS—Z101—WH PROVIDE 5—BUTTON WALL STATION. MANUFACTURER: LUTRON—QSWS2-5BRLI—WH PROVIDE GRAFIK EYE LIGHTING CONTROL UNIT MANUFACTURER: LUTRON—QSGRJ-3P—WH PROVIDE INFRARED TRANSMITTER/RECEIVER PAIR MANUFACTURER: LUTRON—GRX—TRPS—WH. PROVIDE GENERATOR TRANSFER DEVICE INTEGRATED TO LIGHTING FIXTURE. RECEIVED CITY OF TUKWILA APR 10 2017 QERMIT CENTER AZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN # 206-1777 2-81 BUILDING KEY PLAN SCALE: WS 4 2 0 8 12 16 20 II SCALE: SCALE: (FEET) 1/8"=1'-0" SUBTITLE TITLE re LIGHTING PLAN PfiPpRovAii �' 2-81 & DENSITY IMPROVEMENOPQUIR BUILDING 02081 ELECTRICAL MASTER COL. A—F/3-8 PLANT 2, WA. CURRENT REVISION W4833402 SYMBOL 3 DATE 04.06.17 SHEET 2E12 JOB NO. 1001594739 COMP NO. DWG NO. 2-81-2E12 7 _ _ ____ _ _ _ 2E10 2E11 % / / 2E12 2E13 / A , 2-81 BUILDING KEY PLAN SCALE: WS 4 2 0 8 12 16 20 II SCALE: SCALE: (FEET) 1/8"=1'-0" SUBTITLE TITLE re LIGHTING PLAN PfiPpRovAii �' 2-81 & DENSITY IMPROVEMENOPQUIR BUILDING 02081 ELECTRICAL MASTER COL. A—F/3-8 PLANT 2, WA. CURRENT REVISION W4833402 SYMBOL 3 DATE 04.06.17 SHEET 2E12 JOB NO. 1001594739 COMP NO. DWG NO. 2-81-2E12 SWITCHED TOGETHER 2E3—•/25(R5,R6) 27(R7 R8) LCP 2 1 /2"C E3-3/R6,R7,R8 (3) 3/C#20 2E3-2/29 SNA- LC -P LCP 2E3-3/R5,R9,R1 1/2"C, (3) 3/C#20 (2) 3/C#20 -RQ BI Dr (u IIF) SEE 2E11 PARTIAL PLA\ V SCALE: 1/8"=1'-0" �.1 DA. D3.9 REVISION RECORD DRAWING J#972197-00 2-81 & DENSITY IMPROVEMENTS W4833402 BY APPROVED HGI/SDB SAZAN/EA SYM REVISION BY APPROVED DATE 7.28.00 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED 04.06.17 APPROVED BY DRAWN B. BRITTAIN CHECKED S. BERGSTROM ENGINEER B. BRITTAIN CHECKED S. BERGSTROM APPROVED L. COSTELLO APPROVED R. McNIESH LV LECE\D (SEE DRAWING 2-80—E1 FOR LEGEND, GENERAL NOTES AND ABBREVIATIONS) 3/C#20 LOW VOLTAGE WIRE IN CONDUIT, UNLESS OTHERWISE NOTED G E\ PAL \OYES UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THHN/THWN INSULATION, #12 AWG FOR POWER & #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS 208/120V 480/277V "A" PHASE LEFT BUS IN PANEL) BLACK BROWN "B" PHASE CENTER BUS IN PANEL) RED ORANGE "C" PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL GRN/YEL (GREEN W/ YELLOW TRACER) 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG—ON CIRCUIT BREAKERS ON BUSWAYS. 6. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION/OUTLET BOXESS, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. 7. POST NEW OR REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. HFRE\CE DAWI\GS 2-81—E505 "LIGHTING CONTROLS", LOW VOLTAGE 1 S 2-81—E500 LIGHTING FIXTURE SCHEDULE CO\ST�UCTIO\ NOTES PROVIDE LED LIGHTING FIXTURES. REFER TO LIGHTING FIXTURE SCHEDULE ON E500 AND E500a. UTILIZED EXISTING CONDUITS AND CONDUCTORS FOR LED LIGHTING FIXTURES. REUSE EXISTING LIGHTING CIRCUITS, RELAYS, AND CONTROLS. RECEIVED . CITY OF TUKWILA APR 10 2017 PERMIT CENTER A?AN 0 17 O9 2E15 A 2E11 GROUP 2-81 BLDG. 600 Stewart St., Ste 1400 W4833402 Seattle, Washington 98101 PERMIT SUBMITTAL 04.06.17 DATE SUBTITLE 10.30.97 04.07.98 04.07.98 06.03.98 06.03.98 TITLE Tel 206.267.1700 Fax 206.267.1701 SAZAN # 206-1777 LIGHTING PLAN PERmn- 2-81 & DENSITY IMPROVEMENTS 40.z..,! BUILDING 02080 06.03.98 ELECTRICAL MASTER COL. K—P/1-3 PLANT 2, WA. 2 80 BLDG. KEY PLAN SCALE: NTS 4 2 0 4 8 12 16 20 III III SCALE: (FEET) 1 /8"=1 '-0" CURRENT REVISION W4833402 SHEET JOB NO. DWG NO. SYMBOL DATE A 04.06.17 2E15 J#972197-00 COMP NO. 2-80-2E15 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING FIXTURE VOLTAGE FIXTURE INPUT WATTAGE LAMPS BALLAST MANUFACTURERS CATALOG SERIES NUMBER REMARKS SYMBOL TYPE QN, 2'x4', 6" DEEP PARABOLIC TROFFER LAYIN FLUORESCENT FIXTURE, WITH SPECIAL VDT GLARE CONTROL PARABOLIC 27 CELL LOUVER, SECURED BY T-HINGES AND SPRING LOADED CAM LATCHES, ACCESS FROM BOTH SIDES GRID LAYIN W/ CLIPS 277 89 F32T8/735 3500K 3 277V ELECTRONIC LESS THAN 10% THD COLUMBIA HIGH COMFORT HC24-332G-LD39-S-3EB8LH277-GMF A 0 89 2'x4', 6" DEEP PARABOLIC TROFFER LAY-IN FLUORESCENT FIXTURE, WITH SPECIAL VDT GLARE CONTROL PARABOLIC 27 CELL LOUVER, DIMMABLE BALLAST, LOUVER SECURED BY T-HINGES AND SPRING LOADED CAM LATCHES, ACCESS FROM BOTH SIDES GRID LAYIN W/ CLIPS 277 100 F32T8/735 (DIMMABLE LAMPS) 35001< 3 277V LESS THAN 10% THD DIMMABLE BALLAST COLUMBIA HIGH COMFORT HC24-332G-LD39-S-EC010-C388-F0735 VERIFY DIMMABLE AD BALLAST + LAMP - 0 100 COMBINATION COMPATIBLE <7B9> 2'x2' 6" DEEP PARABOLIC TROFFER LAY-IN, SPECIAL VDT LOW GLARE PARABOLIC GRID LAYIN W/ CLIPS 277 79 3500K 3 277V ELECTRONIC LESS THAN 10% THD COLUMBIA HIGH COMFORT HC22-331 U1 G-LD34-S-3EB8LH277-GMF KV 1'x4' 8" DEEP PARABOLIC TROFFER LAYI-N, SPECIAL VDT LOW GLARE PARABOLIC GRID LAYIN W/ CLIPS 277 61 FB31 /31 K 3500K 2 277V ELECTRONIC LESS THAN 10% THD COLUMBIA HIGH COMFORT HC14-232G-LD-112-S-EB8LH277-GMF B2 =we= C PARABOLIC STACK LIGHT FIXTURE 1'x4' LAY-IN, GRID LAPS W/. CLIPS 277 38 F32T8/735 3500K 1 277V ELECTRONIC LESS THAN 10% THD COLUMBIA LSL14-132G-LD18-S-EBHLH277-C388-F0735GMF DATA VAULT RM. 22DB22 o38 DWG. 2-81-2E15 AREA FLOOD LIGHT, AKTRA II CUTOFF TYPE MH FIXTURE, WALL MOUNTED, ALUMINUM CORROSION RESISTANT WITH DARK BRONZE FINISH. SEALED GASKETED LENS. SURFACE 38' A.G. 277 455 400W MH 1 INTEGRAL CWA WIDELITE AKTRA II A2M-400-A-QVC-SW-GR WITH F1-A2-KIT (277V) 38' ABOVE GRADE MOUNT. HT. BUILDING PERIMETER DWG. 2-81-E8, DETAIL "2" SHEET E507 FOR MOUNTING D (455)CAST AREA FLOOD LIGHT, AKTRA II CUTOFF TYPE HPS FIXTURE, POLE MOUNTED,WIDELITE CAST ALUMINUM CORROSION RESISTANT WITH DARK BRONZE FINISH. SEALED GASKETED LENS. POLE 39-40' A.G. 480 465' 400W HPS 1 INTEGRAL CWA AKTRA H A2S-400-E-QVC-M-DB W/ "M" MASTFITTER AND F2-A2-KIT (480V) FUSE KIT MOUNTED ON POLE IN PARKING LOT, SEE DWG E506 DETAIL "2" FOR INSTALLATION DP 465 RECESSED BATTERY BACK-UP GIMBAL LIGHT WITH TEST SWITCH AND INDICATED LIGHT RECESSED 277 8.8 (ON BATTERY ONLY) 8W GIMBAL PRESCOLITE EG1 E0 G K 4' OR 8' INDUSTRIAL PARABOLIC FLUORESCENT, WITH 20% UPLIGHT, PER SECTION, PENDANT 277 75 (4 FT.) 150 (8 FT.) F32T8/735 3500K 2 PER 4' 277V ELECTRONIC LESS THAN 10% THD LITHONIA PARABOLIC INDUSTRIAL, RAPID START PV 232 277 GEB10 GMF (4FT LONG) TPV 232 277 GEB10 GMF TILW (8FT LONG, TANDEM) THUN HANGER MTD TO STRUT "1" _ —•— _ ®4FT. SEE DETAIL ON 75 or 150 SHEET E507 FOR MTG. DETAILS I--() 4' OR 8' INDUSTRIAL FLUORESCENT, WITH 20% UPLIGHT, PER 4FT. SECTION, CLIPPED TO STRUT 277 75 (4 FT.) 150 (8 FT.) F32T8/735 3500K 2 PER 4' 277V ELECTRONIC LESS THAN 10% THD COLUMBIA, DYMO INDUSTRIAL, RAPID START KL4-232-EB8LH 277-GMF (2 TANDEM FOR 8') KTH HANGER MTD TO STRUT —•_ Q SEE DETAIL "1" ON 75 OR 150 ) SHEET E507 FOR MTG. DETAILS—( STACK LIGHT STRIP, WITH PARABOLIC DIFFUSER CLIPPED TO STRUT 277 116 (8 FT.) F32T8/735 3500K 4 277V ELECTRONIC LESS THAN 10% THD COLUMBIA LSLA2D-CM-LD-EB8LH277-MW-8SGL-GMF 116 ) 2'x4', 7" DEEP PARABOLIC TROFFER LAYIN FLUORESCENT FIXTURE, SPECIAL VDT GLARE CONTROL PARABOLIC 27 CELL LOUVER, GRID LAYIN W/ CLIPS 277 59 F32T8/735 3500K 2 277V ELECTRONIC LESS THAN 10% THD COLUMBIA HIGH COMFORT HC24-232G-LD39-S-EB8LH277-GMF H H59 2'x4', 7" DEEP PARABOLIC TROFFER LAY-IN FLUORESCENT FIXTURE, SPECIAL VDT GLARE CONTROL PARABOLIC 27 CELL LOUVER, GRID LAYIN W/ CLIPS 277 75 F32T8/735 (DIMMABLE LAMPS) 3500K 2 277V LESS THAN 10% THD DIMMABLE BALLAST COLUMBIA HIGH COMFORT HC24-232G-LD39-S-DIMMABLE BALLAST VERIFY DIMMABLE BALLAST + LAMP HD COMBINATION COMPATIBLE 75 EXIT SIGN LIGHT LED TYPE, UNIVERSAL MOUNTING, GREEN LETTERS ON WHITE BACKGROUND WITH REMOVABLE DIRECTIONAL ARROWS, WHITE ALUMINUM HOUSING, DBL FACED PENDANT/WALL 277 4 LED PRESCOLITE PRSC EDC2GACW SEE DETAIL "3" ON SHEET E507 FOR MTG. DETAILS®� I-04 (WALL (CLC MTD) MTD) 4 RECESSED INCANDESCENT, CUT INTO CEILING PANEL RECESSED 120 200 200W A-23 1 PRESCOLITE, 6" APERTURE 1058-736 CLEAR ALZAK CONE SOUND DEMO FACILITY RM 14G4 3 K20) INCANDSCENT CYLINDER DOWNLIGHT CYLINDER SURFACE & PENDANT 120 200 200W A-23 1 PRESCOLITE, 8" CYLINDER 1146-462 BL CLEAR REFLECTOR/MATTE BLACK FINISH CRITICAL LISTENING ROOM RM 11H4 & RM 12G5 K 200 COMPACT RECESSED FLUORESCENT, FUSED WBALLASTITH CLEAR ALZAK CONE, INTELECT ELECTRONIC RECESSED 277 60 26W/3500K COMP. FLOUR. QUAD 4-PIN 2 277V ELECTRONIC INTELECT PRESCOLITE #CFR626EB-ST372A-FSDFA 277V (B-24 OPTION WHEN PLACED IN T-BAR CEILING) 0 K 61-0) COMPACT RECESSED WALL WASH FLUORESCENT, FUSED WITH CLEAR ALZAK CONE, INTELECT ELECTRONIC BALLAST RECESSED 277 40 13W/3500K TWIN COMP. FLOUR. 4-PIN 2 277V ELECTRONIC INTELECT PRESCOLITE #CFW813EB-ST812-FSDFA 277V OPEN HALF INDICATES DIRECTION OF LIGHT CASTED FROM FIXTURE LW 40 LOW BAY T5-HO FLUORESCENT WITH OCCUPANCY SENSOR PENDANT 277 117 F54T5/841/HO 4100K 2 120-277V ELECTRONIC PROGRAMMED START 1ST SOURCE LIGHTING, ULB SERIES, WITH UPLIGHT, WIRE GUARD, MIRO4 REFLECTOR, AND SOCKETED 360 DEGREE WATT-STOPPER OCCUPANCY SENSOR REPLACEMENT FOR HID, ®REPLACEMENT _ =•— ® ABOVE BRIDGE CRANE MTG. SURFACE MOUNT FLUORESCENT, FOR STAIRWELL WRAP AROUND ACRYLIC LENS SURFACE 277 84 F32T8/735 3500K 2 PER 4' 277V ELECTRONIC LESS THAN 10% THD COLUMBIA W4-232-EB8LH 277-GMF (WALL MOUNT) AD4-232-EB8LH 277-GMF (CEILING MOUNT) CONNECTED TO EMERGENCY N CIRCUIT, SEE PLANS `' 4) 84 1'x4' DIRECT/INDIRECT WALL MTD. RESTROOM WALL LIGHT, PARABOLIC DOWNLIGHT ENAMEL FINISH COLOR TO MATCH WALL SURFACE 8' A.F.F. 277 75 F32T8/735 3500K 2 PSR 277V ELECTRONIC LESS THAN 10% THD COLUMBIA MS6A3-42-411-1-277 FINISH TO MATCH WALL COLOR RESTROOM WALL LIGHT 0 -•- 75 2'x4' SPECIFICATION GRADE NON-AIR TROFFER WITH ACRYLIC A54 SMOOTH LENS, 3-LAMP GRID LAYIN W/ CLIPS 277 86 F32T8/735 3500K 3 277V ELECTRONIC LESS THAN 10% THD COLUMBIA 4PS24-332G-FSA55-3EB8LH277-GMF P 86 1'x4' SPECIFICATION GRADE NON-AIR TROFFER WITH ACRYLIC A54 SMOOTH LENS, 2-LAMP GRID LAYIN W/ CLIPS 277 56 F32T8/735 3500K 2 277V ELECTRONIC LESS THAN 1O% THD COLUMBIA 4PS14-232G-FSA55-3EB8LH277-GMF Q _ _ —�— 56 PORCELAIN BASE KEYLESS INCANDESCENT SURFACE 120 60 A19/ 60W 1 PASS & SEYMOUR 44 ELEVATOR SHAFT R 60 AREA FLOOD FOR BUILDING ENTRANCES, TOTALLY ENCLOSED, WEATHER RESISTANT SURFACE 277 115 100W M.H. 1 INTEGRAL CWA G.E. WALLIGHTER 175 LUMINAIRE W1 LR1 OM 4 A 1 A MN2 DB F DOOR ENTRANCES, SEE DETAIL "4" SHEET E507 FOR MTG. DETAILS S 115 4' LONG SRIPLIGHT, STEEL HOUSING WITH BAKED ENAMEL FINISH SURFACE IN COVE 277 62 F32T8/735 3500K 2 277V ELECTRONIC LESS THAN 10% THD COLUMBIA STRAIGHTLINER CS4-232-4EB8LH277-GMF BATHROOM, ABOVE MIRROR KT =0= 62 COVE 12' OF TRACK LIGHTS, SINGLE CIRCUIT, WHITE FINISH - SURFACE OF SUSPENDED CEILING 120 (6) 75W = 450 75W PAR-30 NFL (NARROW) 6 PRESCOLITE TS12 (12' TRACK) W/ (6) TV113 ROUND BACK CYLINDERS TL 450 U (115)NORTH ENTRANCES (2) PENDANT HID CYLINDER PENDANT 8'-0" MIN. 277 115 100W MH 1 INTEGRAL CWA PRESCOLITE HID CYLINDER, HD10P13 Z 277V GMF (SHORTEN PENDANT IF NECESSARY) (2) NORTH SIDE SIDE BUILDING ENTRANCE CANOPIES 0 MAIN ENTRANCE RECESSED ELLIPSOIDAL H.I.D RECESSED 10'-8" 277 115 100W MH 1 INTEGRAL CWA PRESCOLITE HID RECESSED DOWNLIGHT 90M5-100MHFE-M8-GMF SOUTH SIDE MAIN BUILDING ENTRANCE CANOPY p Alik ® LED HIGH BAY RECTANGULAR, 4 FT LONG, CLEAR ACRYLIC LENS, NO BAFFLE CABLE 277 110 LED - INTEGRAL ELECTRONIC LW-LUSIO-ES2-2M-50-CA-BAFN 19 FEET 1 1 1W110 LED HIGH BAY RECTANGULAR, 2 FT LONG, CLEAR ACRYLIC LENS WITH BAFFLE CABLE 277 59 LED - ELECTRONIC LW-LUSIO-ES2-2MS-50-CA-BAFY WINTEGRAL 2 10 FEET 59 _1 "" P•, - .\ .• PI _0, , 4. k 4 'aF A: _0 � -. W3INTEGRAL - 1.""mr 2'x4', LED TYPE FIXTURE, HIGH PERFORMANCE RECESSED, DIFFUSE CENTER OPTIC, RECESSED 277 27 HPR LED 3500K - INTEGRAL ELECTRONIC FINELITE SERIES HPR LED HPRLED-2X4-A-DCO-S-835-277V RL1 10 FEET 27 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE RECORD DRAWING J#972197-00 HGI/SDB 11.12.99 REPLACE HID FIXTURES J#535314-00 KNOX CAS 10.03.13 CDC RELOCATION — WIRE SHOP RELOCATION J#19760 CASNE CEC 11.11.13 RECORD DRAWING J#19760 11.17.14 2-81 & DENSITY IMPROVEMENTS W4833402 SAZAN/EA 04.06.17 BOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN B. BRITTAIN CHECKED S. BERGSTROM ENGINEER B. BRITTAIN CHECKED S. BERGSTROM APPROVED L. COSTELLO APPROVED R. McNIESH DATE 01.25.98 04.08.98 04.08.98 06.03.98 06.03.98 06.03.98 SUBTITLE TITLE LEGE\D FIXTURES SHOWN SOLID WITH "E" DESIGNATION IN CENTER ARE THE SAME FIXTURE ONLY CONNECTED TO EMERGENCY POWER CIRCUIT, SEE PLAN DWG'S GE\PAL \CTES 1. FOR LIGHTING INSTALLATION DETAILS SEE DWG. 2-081-E507 EFRE\ CE DAWI\GS CO ST�UCTIO\ \OTES RECEIVED CITY OF TUICWILA APR 1 X017 PERMIT CENTER W4833402 PERMIT SUBMITTAL 04.06.17 • LIGHTING FIXTURE SCHEDULE ELECTRICAL MASTER 2-81 & DENSITY IMPROVEMENTS BUILDING 02-081 CURRENT REVISION W4833402 PLANT 2. WA AZAN GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 Tel 206.267.1700 Fax 206.267.1701 SAZAN # 206-1777 SYMBOL E500 DATE 04.06.17 JOB NO. COMP NO. DWG NO. 2-81-E500 LIGHT FIXTURE SCHEDULE TYPE DESCRIPTION MOUNTING FIXTURE VOLTAGE FIXTURE INPUT WATTAGE LAMPS BALLAST MANUFACTURERS CATALOG SERIES NUMBER REMARKS SYMBOL TYPE QTY. KR2) 9 RECESSED LINEAR LED WALL WASH FIXTURE, NARROW APERTURE, EXTRUDED ALUMINUM HOUSING, ASYMMETRIC 20 DEG SHIELDING, RECESSED 277 9W/FT LED 3500K - INTEGRAL ELECTRONIC SELUX M36 LED RECESSED A2 WALL WASH L36 -1A25 -35-A2 - 4" LED RECESSED DOWNLIGHT, SQUARE TRIM, GALVANIZED STEEL HOUSING, SEMI -SPECULAR REFLECTOR, 0-10V DIMMING RECESSED 277 10 LED 3500K _ INTEGRAL ELECTRONIC GOTHAM 4" INCITO SQUARE ICOSQ-35-10-4WR-LSS-60D - 0 /RL3\ 10 /RL4\4" 14 LED RECESSED DOWNLIGHT, SQUARE TRIM, POWDER COATED STANDARD ACCENT TRIM, RECESSED 14 LED 3000K - INTEGRAL ELECTRONIC ZANEEN 4D1 LED L37943 - 0 3" APERTURE LINEAR RECESSED LED FIXTURE, EXTRUDED ALUMINUM TRIM, ACRYLIC MATTE FINISH LENS, RECESSED 277 5W/FT LED 3000K - INTEGRAL ELECTRONIC PINNACLE EV3A W/ SATINE LENS EV3A-30-XX-FL-UNV - _ _ _ KRL5) 5 LED PENDANT MOUNTED LUMINAIRE, AIR CRAFT CABLE SUSPENDED, 0-10V DIMMING, EXTRUDED ANODIZED ALUMINUM BODY, CLEAR ACRYLIC LENS SUSPENDED +8'-6" AFF 277 38 LED 3500K - INTEGRAL ELECTRONIC FLUXWERX VIEW -RADIUS VU1-R-B-D-35-A - HL1 38 LED PENDANT MOUNTED LUMINAIRE, SINGLE MOUNTED HEAD W/ REMOTEUUMEQ DRIVER, EXTRUDED ALUMINUM HOUSING, -IS-8 _P DAN 277 15 LED 3000K • - INTEGRAL ELECTRONIC ALW LIGHTPLANE 9 MONO UNIT LP9SM1-CZEN1200-0/10V-AL - a ® W LED PENDANT MOUNTED LUMINAIRE, AIR CRAFT CABLE SUSPENDED, 0-10V DIMMING, EXTRUDED ACRYLIC LENSED BODY SUSPENDED +8'-6" AFF 277 24 LED 3500K - INTEGRAL ELECTRONIC ALW CLARA CLEAR LENS BODY CLA-4'-LED/3500K-0/10V-CLR - HL3 24 LED UNDERCABINET LUMINAIRE, 1' DEEP PROFILE, EXTRUDED ALUMINUM HOUSING, ACRYLIC TEXTURED LENS, UNDERCABINET 277 7 LED 3000K _ INTEGRAL ELECTRONIC PHILIPS DAY-BRITE LINCS LED UNDERCABINET LINCS100E-L28-930-277-WHG-DIM - ® I I W LEGEND FIXTURES SHOWN SOLID WITH "E" DESIGNATION IN CENTER ARE THE SAME FIXTURE ONLY CONNECTED TO EMERGENCY POWER CIRCUIT, SEE PLAN DWG'S PAL \OTES 1. FOR LIGHTING INSTALLATION DETAILS SEE DWG. 2-081-E507 EFERE\CE NAWI\GS CO\ST�UCTIO\ \OTES W4833402 PERMIT SUBMITTAL 04.06.17 REVISION 2-81 & DENSITY IMPROVEMENTS APPROVED REVISION APPROVED W4833402 04.06.17 g� OE/NG° — ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY SUBTITLE CHECKED LIGHTING FIXTURE SCHEDULE TITLE 2-81 & DENSITY IMPROVEMENTS CURRENT REVISION W4833402 GROUP 600 Stewart St., Ste 1400 Seattle, Washington 98101 � Tel 206.267.1700 Fax 206.267.1701 SAZAN # 206-1777 SYMBOL 04.06.17 CHECKED APPROVED BUILDING 02081 E500a COMP NO. APPROVED ELECTRICAL MASTER PLANT 2, WA DWG N0. 2-81-E500a SYM 2'-0%" 8 W1 x26 7 S413 S414 TYP S413 S413 E\LAGGED RAN SCALE: 3/4'=1'-0" I\G PLA\ HGR SEE PLAN BM SEE PLAN L4x4xY4 BRACE [TOS=32'-8"] --S VERT BRACE TYP (71- S162 S413 L4x4xY4 BRACE [TOS=32'-8"] E\LAKEI S413 W16x45 [TOS=33'-4 HGR SEE PLAN FAVI\G PLA VERT BRACE TYP 2 SCALE: 3/4'=1'-0 REVISION BY APPROVED DATE S1621S413 TYP EA END 5413 11 HGR SEE PLAN, TYP PA SYM S413 S414 HGR SEE PLAN S414 L5x5x5/16 BRACE BM SEE PLAN, TYP PATITIO\ SUPPORT SECTIO\ SCALE: 3/4'=1'-0" HGR SEE PLAN BM SEE PLAN, TYP S413 S414 TYP PATITIO\ SUPPORT SECTIO\ SCALE: 3/4'=1'-0" BM SEE PLAN, TYP pan Agili, S413 S414 L5x5x 16 / BRACE S413 TYP EA HGR UON S413 S414 OPH �TITIO SCALE: 3/4'=1'-0" BM SEE PLAN, TYP SUPPORT SECTIO\ (16‘ S413 BRACE SEE C/5162 (E) BM SEE PLAN, TYP GUSSET PL FOR LATERAL BRACE EA HGR S414 S413 T e SEE PLAN REVISION BY APPROVED DATE 2-81 DENSITY IMPROVEMENTS W4866402 CEI EO 04.28.17 S162 S413 EZ V ® HGR SEE PLAN -/ HGR SEE PLAN BM SEE PLAN, TYP PATITIO\ SUPPORT SECTIO\ SCALE: 3/4'=1'-0" S. BRACE SEE C/S162 BM SEE PLAN, tt• TYP S413 S414 TYP (E) BM SEE PLAN, TYP HGR SEE PLAN PATITI O \ SU SCALE: 3/4'=1' -0" 90% RE -SUBMITTAL 04.28.2017 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE ONAL DRAWN R. REEVES CHECKED H. O'BRIEN ENGINEER H. O'BRIEN CHE KED E. OJALA APPROVED APPROV D DATE 04.28.17 04.28.17 04.28.17 04.28.17 SUBTITLE TITLE L5x5x546 BRACE TYP © EA HGR P S413 S414 BM SEE PLAN, TYP OT SECTIO\ S413 S414 TYP AFOFFMAN I N E E R S 1601 Fifth Avenue, Suite 9001 Seattle, WA 98101 ph 206.623.07171 fax 206.624.3775 coffman.com LASTING creativity results !relationships MISCELLANEOUS SECTIONS & DETAILS STRUCTURAL MASTER 2-81 DENSITY IMPROVEMENTS 02-81 BUILDING PLANT 2, WA CURRENT REVISION W4833402 S413 REVIEWED FOR CODE COMPLIANCE APPROVED MAY102017 C6ty Of Tukwila BU1 !:� .flIvJ a40%! SYMBOL RECEIVED CITY OF TUKWILA MAY 0 3 2017 PERMIT CENTER DATE 04.28.17 SHEET S413 JOB NO. W4833402 COMP NO. DWG NO. 02-81-S413 S';v1 BM SEE PLAN, TYP PLY2x5x0'-9" W/ (4) /"O BOLTS HGR SEE PLAN HA\GES CO\\ ECTI O \ DETAIL SECTION A -A 1 SCALE: 1'=l' -O" HGR SEE PLAN GUSSET PL, SEE 4/S414, SIM Y4VE PLY2x8xAS REQD W/ (4) /4"0 BOLTS 3Y" 3Y2" )" 2 1Y" 2 BM SEE PLAN, TYP NOTE: 1. SEE 4/S414 FOR ALL INFO NOT SHOWN. 3ACE CO\\ECTIO\ AT HA\GES SCALE: 1'=1'-0" S413I S414 S413 15414 BRACE SEE EL GUSSET PL546 w/ (2) 3/" O BOLTS BM SEE PLAN, TYP 3ACE C3\ \ ECTI O \ BRACE SEE EL DETAIL 2 SCALE: 1'=1'-O" LY2" MIN, 7/"0 BOLTS L BM 3" 2" SEE SCHED FOR CONN -PL & BOLTS BEAM -BEAM CONNECTION SEE SCHED S413IS414 5 TYPICAL SI\GLE OW CO\\ECTIO\ DETAIL SCALE: NTS BM SEE PLAN 11 I> L3Yx3Yx5/16x0'-6" TYP W/ (2) BOLTS GUSSET PL 516" [TOS=32'-734"] BRACE SEE PLAN - W/ (2) BOLTS HOIZ 3ACE CO\ r. r. \ ECTIO\ DETAIL WP BM SEE PLAN SCALE: 1'=1'-0" REVISION BY APPROVED DATE SYM S413 S414 REVISION (E) BM SEE PLAN, TYP TYP 3EAv FLAN I \G CO\\ECTIO\ AT EXIST SEAM SCALE: 1'=1'-0" (3� S413I S414 SINGLE ROW BOLTED CONNECTION SCHEDULE PER AISC, LRFD - LOAD AND RESISTANCE FACTOR DESIGN, 14TH EDITION BEAM SIZE VERTICAL CAPACITY (KIPS) NO. OF BOLTS (INCHES) CONN -PL THK (INCHES) WELD SIZE (INCHES) H -PL THK (INCHES) MIN SU ORT THK (INCHES) C 15 3 7.8 (3) 7/8"0 3/8 5/16 — 0.217 W8, C8 19.0 (2) 7/8"0 3/8 5/6 Y2 0.210 W1 0 19.0 (2) 7/8"0 3/8 5/6 Y2 0.210 W1 2, C 12 23.0 (3) 7/8"0 3/8 5/16 Y2 0.217 W1 4 36.9 (3) 7/8"0 3/8 5/6 Y2 0.217 W1 6 5 6.2 (4) 7/8"6 3/8 5/ 6 Y2 0.233 W18 84.4 (5) 7/8"0 Y2 3/8 Y2 0.270 GUSSET PL546 W/ (2) /"O BOLTS Y (E) BM CONT WHERE OCCURS 3ACE CO\\ECTIO\ DETAIL SCALE: 1'=1'-0" GUSSET PL PLY W/ (4) %4" O BOLTS (4) BM GA SECTION A -A S413 S414 CONNECTION NOTES: 1. BEAM DESIGN VERTICAL REACTIONS SHOWN ON PLAN (EX 14k = 14 KIPS) ARE FACTORED LOADS. MINIMUM CONNECTION CAPACITY SHALL BE 9 KIPS, FACTORED LOAD, (2) BOLT SINGLE ROW CONNECTIONS. 2. ALTERNATE CONNECTIONS MAY BE SUBSTITUTED FOR SINGLE TAB CONNECTION PLATES, PROVIDED THEY MEET OR EXCEED THE REQUIREMENTS OF THE AISC AND THE REACTIONS SHOWN ON PLAN. ALTERNATE CONNECTIONS MUST BE SUBMITTED FOR REVIEW PRIOR TO SHOP DRAWING REVIEW. USE THE MINIMUM NUMBER OF BOLTS REQUIRED FOR THE BEAM SIZE PER THE TABLE ABOVE. 3. WHERE A LARGER BEAM FRAMES INTO A SMALLER BEAM, USE THE MINIMUM NUMBER OF BOLTS REQUIRED FOR THE SMALLER BEAM SIZE PROVIDED THAT THE BEAM REACTION IS MET. USE DOUBLE ROW CONNECTIONS WHERE SINGLE ROW CONNECTION CAPACITIES ARE INSUFFICIENT. 4. BEAMS SHALL HAVE STANDARD ROUND HOLES AND CONNECTION PLATES MAY HAVE HORIZONTAL SHORT SLOTTED HOLES. 5. USE TYPICAL SCHEDULE NOTES "BOLTS ARE A325 -N, BOLTS MAY BE SNUG TIGHT, UNLESS SPECIFICALLY CALLED OUT AS SLIP CRITICAL" 6. CONNECTIONS MARKED SLIP CRITICAL OR DOUBLE ROW ON THE PLAN CONTAIN HORIZONTAL REACTIONS. USE CONNECTIONS FOR THE BEAM SIZE. PROVIDE STANDARD ROUND HOLES IN BOTH 7. THE BEAM AND SHEAR TAB AND SLIP -CRITICAL BOLTS. THE CONNECTION PLATE BOLTS HAVE A MINIMUM EDGE DISTANCE OF 1-1/2" VERTICAL AND HORIZONTAL (EXAMPLE SINGLE ROW CONNECTION WITH (4) BOLTS, PLATE LENGTH = 12" MIN). THE 8. BEAM WEB BOLTS HAVE A MINIMUM EDGE DISTANCE OF 1-1/2" VERTICAL AND HORIZONTAL (EXAMPLE SINGLE ROW CONNECTION WITH (4) BOLTS, WEB LENGTH = 12" MIN). A BEAM COPE THAT DECREASES THE BEAM WEB BEYOND THIS MINIMUM MUST BE SUBMITTED FOR REVIEW PRIOR TO SHOP DRAWING REVIEW. THE SUPPORTING BEAM OR COLUMN, WEB OR FLANGE THICKNESS, THAT THE CONNECTION PLATE IS WELDED TO, SHALL MEET THE MINIMUM SUPPORT THICKNESS LISTED IN SCHEDULE. 9. W8x15 MINIMUM FOR W8 LISTED IN SCHEDULE. BM SEE PLAN OPERABLE PARTITION. CONNECTION PER MFR INSTRUCTIONS. TYPICAL OPHA3LE PATITIC\ WALL CON \ECTIO\ DETAIL SCALE: 1'=1'-O" BY APPROVED DATE 2-81 DENSITY IMPROVEMENTS W4866402 CEI E0 04.28.17 (8 S414 90% RE -SUBMITTAL 04.28.2017 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN R. REEVES DATE SUBTITLE 04.28.17 CHECKED H. O'BRIEN 04.28.17 AFOFFMAN NGIREERS 1601 Fifth Avenue, Suite 900 I Seattle, ph 206.623.07171 fax 206.624.3775 coffman.com LASTING creativity l results 1 relationships REVIEVVED FOR CODE COMPLIANCE APPROVED MAY 10 2017 City of Tukwila BUILDING DIVISION re," S414 CORRE�TiON LTR# RECEIVED CITY OF TUKWILA MAY 0.3 2017 PERMIT CENTER MISCELLANEOUS SECTIONS & DETAIL miote T REVISI W4833402 04.28.17 APPROVED BY DEPT. DATE ENGINEER H. O'BRIEN 04.28.17 CHECKED E. OJALA 04.28.17 APPROVED APPROVED TITLE STRUCTURAL MASTER 2-81 DENSITY IMPROVEMENTS 02-81 BUILDING SHEET S414 JOB NO. W4833402 COMP NO. PLANT 2, WA DWG NO. 02-81-S414