Loading...
HomeMy WebLinkAboutPermit D17-0170 - T-MOBILE - BOW LAKE RADIO REPLACEMENTST -MOBILE 1800 ORILLIA RD S D17-0170 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov DEVELOPMENT PERMIT Parcel No: 3523049037 Permit Number: D17-0170 Address: 18800 ORILLIA RD S Issue Date: 12/7/2017 Permit Expires On: 6/5/2018 Project Name: T -MOBILE Owner: Name: KING COUNTY -SOLID WASTE Address: 201 S JACKSON ST #701 , SEATTLE, ID, 98104 Contact Person: Name: ERIC SHAW Phone: (208) 963-4014 Address: 219 S WOODDALE AVE , EAGLE, ID, 83616 Contractor: Name: SAC WIRELESS LLC Phone: (847) 944-1600 Address: 540 MADISON ST 16th FLOOR, CHICAGO, IL, 60661 License No: SACWIWL852J2 Expiration Date: 7/1/2019 Lender: Name: T -MOBILE Address: 3625 132 AVE SE , BELLEVUE, WA, 98006 DESCRIPTION OF WORK: AT ANTENNA LEVEL, REMOVE (2) FXFB UNITS AND (4) TMA UNITS, INSTALL (2) FHFB UNITS AND (4) NEW TMA UNITS AND (4) DIPLEXERS. AT GROUND LEVEL, REMOVE (2) FSME AND INSTALL (2) FSMF AND (1) FXFB. THERE WILL BE NO INCREASE TO THE EXISTING TOWER HEIGHT AND THERE WILL BE NO EXPASION TO THE EXISTING COMPOUND SQUARE FOOTAGE, AND THERE WILL NOT BE A "SUBSTANTIAL CHANGE" Project Valuation: $20,000.00 Type of Fire Protection: Sprinklers: Fire Alarm: Type of Construction: VB Electrical Service Provided by: TUKWILA Fees Collected: $850.34 Occupancy per IBC: U Water District: HIGHLINE Sewer District: NONE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Volumes: Cut: 0 Fill: 0 Number: 0 No Permit Center Authorized Signature: Date: lc) (7 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: eh", S r/4e, Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 1 ( `O i 7 tJ Project No. Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 3523049037 Site Address: 18800 Orillia Road South, Tukwila WA 98188 Suite Number: Floor: Tenant Name: T-Mobile/American Towers PROPERTY OWNER Name: Eric Shaw/Powder River Development LLC Name: American Tower Corporation City: Eagle State: ID Zip: 83616 Address: 10 Presidential Way Email: eric.shaw@powderriverdev.com City: Woburn State: MA Zip: 01801 CONTACT PERSON — person receiving all project communication Name: Eric Shaw/Powder River Development LLC Address: 219 S Wooddale Ave City: Eagle State: ID Zip: 83616 Phone: (208) 963-4014 Fax: (208) 938-8855 Email: eric.shaw@powderriverdev.com GENERAL CONTRACTOR INFORMATION Company Name: TBD Address: Company Name: "2 r• t City: 4 17 t City: State: Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H \Applicafions\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11. docx Revised_ August 2011 bh New Tenant: ❑ Yes Q] ..No ARCHITECT OF RECORD Name: + t'l,`(LC 1,vC Sk L,LC. Address: Company Name: "2 r• t City: 4 17 t Architect Name: State: i, Zipil 1 rk... k., t Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: + t'l,`(LC 1,vC Sk L,LC. Address: Company Name: "2 r• t City: 4 17 t Engineer Name: State: i, Zipil 1 rk... k., t Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095),, Name: + t'l,`(LC 1,vC Sk L,LC. Address: , "2 r• t City: 4 17 t t State: i, Zipil 1 rk... k., t Page I of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 20,000 Describe the scope of work (please provide detailed information): Existing Building Valuation: $ The scope of work of this project consists of the following: AT ANTENNA LEVEL, REMOVE (2) FXFB UNITS AND (4) TMA UNITS. INSTALL (2) FHFB UNITS AND (4) NEW TMA UNITS AND (4) DIPLEXERS. AT GROUND LEVEL, REMOVE (2) FSME AND INSTALL (2) FSMF AND (1) FXFB. There will be no increase to the existing tower height and there will be no expansion to the existing compound square footage, and therefore will not be a `substantial change' Will there be new rack storage? ❑ Yes Z.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq 11): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes". explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2- x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system. provide 2 copies of a current septic design approved by King County Health Department. H. \Applica0ons\Forms-Applications On lane \2011 Applications\Permit Application Revised - 8-9-11. does Revised_ August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC la Floor 2nd Floor 3`d Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq 11): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes". explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2- x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system. provide 2 copies of a current septic design approved by King County Health Department. H. \Applica0ons\Forms-Applications On lane \2011 Applications\Permit Application Revised - 8-9-11. does Revised_ August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): The scope of work of this project consists of the following: AT ANTENNA LEVEL, REMOVE (2) FXFB UNITS AND (4) TMA UNITS. INSTALL (2) FHFB UNITS AND (4) NEW TMA UNITS AND (4) DIPLEXERS. AT GROUND LEVEL, REMOVE (2) FSME AND INSTALL (2) FSMF AND (1) FXFB. There will be no increase to the existing tower height and there will be no expansion to the existing compound square footage, and therefore will not be a `substantial change' Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ ...Tukwila ❑... Water District 4125 9 ...Water Availability Provided Sewer District ❑ ...Tukwila ❑ ...Sewer Use Certificate 0 .. Highline ❑...Valley View ❑ .. Renton 9... Sewer Availability Provided ❑ .. Renton 0 .. Seattle Septic System: 9 On-site Septic System — For on-site septic system. provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ ...Civil Plans (Maximum Paper Size — 22" x 34") 9 ...Technical Information Report (Storm Drainage) 9 .. Geotechnical Report ❑ ...Traffic Impact Analysis ❑ ...Bond 9 .. Insurance 9 .. Easement(s) 9 .. Maintenance Agreement(s) ❑...Hold Harmless — (SAO) ❑...Hold Harmless — (ROW) Proposed Activities (mark boxes that apply): 9 ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 0 ...Total Cut 0 ...Total Fill cubic yards cubic yards 9 ...Sanitary Side Sewer 0 ...Cap or Remove Utilities ❑ ...Frontage Improvements ❑ ...Traffic Control ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ .. Right-of-way Use - Profit for less than 72 hours 0 .. Right-of-way Use — Potential Disturbance 0 .. Work in Flood Zone ❑ .. Storm Drainage 9 .. Abandon Septic Tank ❑ .. Curb Cut 9 .. Pavement Cut 0 .. Looped Fire Line ❑ ...Permanent Water Meter Size... WO # ❑ ...Temporary Water Meter Size .. WO # ❑ ...Water Only' Meter Size WO # ❑ ...Sewer Main Extension Public 9 Private ❑ CI ...Water Main Extension Public 9 Private 0 ❑ .. Grease Interceptor ❑ .. Channelization 9 .. Trench Excavation ❑ .. Utility Undergrounding 9 ... Deduct Water Meter Size FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 9 ...Water ❑ ...Sewer 9 ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H. \Applications\Forms-Applications On Line \2011 Applications \Permit Application Revised - 8-9-11. docx Revised_ August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE REAL) AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY TH LA S OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR LITHO ►IZ D 1 AGENT: Signature: Print Name: Eric Shaw Mailing Address: 219 S Wooddale Ave H.\Applications\Forms-Apphcations On Line \2011 Applications\Permit Application Revised - 8-0-1 I doca Revised. August 2011 bh Date: 06/13/2017 Day Telephone: (208) 963-4010 Eagle ID 83616 City Stale Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PermitTRAK PAID $521.01 D17-0170 Address: 18800 ORILLIA RD S Apn: 3523049037 $521.01 DEVELOPMENT $496.41 PERMIT FEE R000.322.100.00.00 0.00 $491.91 WASHINGTON STATE SURCHARGE B640.237.114 0.00 $4.50 TECHNOLOGY FEE $24.60 TECHNOLOGY FEE R000.322.900.04.00 0.00 TOTAL FEES PAID BY RECEIPT: R11963 $24.60 $521.01 Date Paid: Thursday, July 20, 2017 Paid By: POWDER RVIER DEVELOPMENT Pay Method: CHECK 029782 Printed: Thursday, July 20, 2017 1:01 PM 1 of 1 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $329.33 D17-0170 Address: 18800 ORILLIA RD S Apn: 3523049037 $329.33 Credit Card Fee $9.59 Credit Card Fee R000.369.908.00.00 0.00 $9.59 DEVELOPMENT $319.74 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R11790 R000.345.830.00.00 0.00 $319.74 $329.33 Date Paid: Thursday, June 22, 2017 Paid By: SCOTT ALPHA Pay Method: CREDIT CARD 612202 Printed: Thursday, June 22, 2017 2:20 PM 1 of 1 SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 'I 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Dri-0/7 Project:o Ii - 1./1,Db i Le Type of Inspection: �,t, i(-1,- vt,L Address: - MOO On LLIA gj CI Date Called: 3-1z-Z1>i �-, Special Instructions: CI e,1 L 1 e....., ----Requester: Date Wanted: - f3 - 2 J a.m./ �m. Enc., Phone No: 1 -208 -?,3 -- 96(9 50 Approved per applicable codes. Corrections required prior to approval. COMMENTS: ...L/Vs .11 (Two, ,Jc..A) gI`o OA) t.c 7 i4 -I--, /i e),D) l3Li fill.1-z--�1'2f Inspector: Eco Date: 3, Iv_10/cf,, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FILE COPY T Mobi1e• ATC ASSET #: 414339 SITE NAME: BOW LAKE TRANSFER USWES L.A7,,HyINK as\ APPROVED changes can be made. to these 8 r pians without approval from the Planning Division of DCD approved By: r -a to: -77— ti SITE INFORMATION TOWER OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 SITE ADDRESS: 18800 ORILLIA RD S. TUKWILA, WA 98188 COUNTY: KING LATITUDE: LONGITUDE: GROUND ELEVATION: 47.43322' —122.26966' 277' AMSL POWER PROVIDER: PUGET SOUND ENERGY TELCO PROVIDER: CENTURYLINK OCCUPANCY TYPE: UNMANNED ZONING JURISDICTION: CITY OF TUKWILA ZONING CODE: C PARCEL NUMBER: 3523049037 CONTACT INFORMATION A&E SERVICES: POWDER RIVER ENGINEERING SERVICES, LLC. 219 S. WOODDALE AVE. EAGLE, ID 83616 CONTACT: JASON BROWN PHONE: 208.938.8844 EMAIL: jason.brown@powderriverdev.com ENGINEERING: POWDER RIVER ENGINEERING SERVICES, LLC. 219 S. WOODDALE AVE. EAGLE, ID 83616 CONTACT: DONALD W. GEORGE, PE, SE, MLSE PHONE: 208.9 38.8844 EMAIL: don.georgeOpowderriverdev.com APPLICANT: T—MOBILE WEST LLC 3625 132ND AVE SE BELLEVUE, WA 98006 CONTACT: PHONE: EMAIL: APPLICANT: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 CONTACT: JENNIFER EVENSON PHONE: 206.427.6880 EMAIL: jennifer.evenson®americantower.com F 1 c h?r , the 'I of a;_ SITE NUMBER: SE03858A FILE NAME: 8A BOW LAKE TRANSFER USWES CAPACITY L1900 FCD CENT 170501 LOCATION: 18800 ORILLIA RD S., TUKWILA, WA 98188 60' MONOPOLE CAPACITY L1900 No. b 11- 0317 0 err rs and REVIEWED FOR CODE COMPLIANCE APPROVED JUL l7 2011 �rT VICINITY MAP SITE PHOT '11-41vv 5_N,arn Sremenon Port OrcM1rd _as: nod 0c at wyvt sou,d Ba.nbr,dge Island BPo Harbor Lox ..red VaLLor lash 'not Tacoma Unlversay Place v " s:eearoom ' M,dland LakewoodParkland"„ MCCMrd A.+ ror<e Base Beaat W dl",Me. .vr9wa« Seattle v all Kirkland Redmond Bellevue Samna -nun Mercer Mand Ne«cas le Cast ar„n nemnts Penwn ,vo,ard, City of TukvMil till GING MVI le cdgmood; er Puyallup'-Bmr DRIVING DIRECTIONS DIRECTIONS FROM SEATTLE/TACOMA INTERNATIONAL AIRPORT: SECA7ATE PERMIT DEPART AIRPORT (SOUTH). TAKE RAMP RIGHT FOR WA -518 EAST TOWARD, SEATTLfOl} TEcAjP PORTLAND / TACOMA. 1-5 SOUTH TAKE THE S. 188TH ST EXIT (EXIT 15). STAY IC l9NN �fl —5 LEFT AFTER 1-5 OVER PASS. DRIVE NORTH INTO TRANSFER STATION COMPLEX. SITE I LOCATED ON LEFT E CODE 0715. THIS SITE IS EQUIPPED WITH THE CYBERLOCK SO ACCESS TfJ EQUI T eiffiES_ESCORT I REVlSiONS 1ICC��11 rh1 ' '',r r,do, to the clog p r ?";prov;-11 f .; 111 liThAsion ie1 Al ^' SLbr`.11tfal reA,t—i foci; £ iectnca) Plumbing Li/Gas Piping ,;;yam Tukwila RIGHT FOR 1-5 SOUTH TOWARD PROCEEDING EAST. TAKE 2ND AND SIDE. LOCK COMBO r PERSONNEL DOES NOT HAVE DO NOT SCALE`E? T.s a aiviblUN CONTRACTOR SHALL VERIFY ALL PLANS & EXISTING DIMENSIONS & CONDITIONS ON THE JOB SITE & SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME City of Tukwila BUILDING DIVISION JC)N A DRAWING INDEX DESCRIPTION REV SHE NO. T-1 TITLE SHEET 0 GN -1 GENERAL NOTES 0 GN -2 GENERAL NOTES 0 C-1 SITE PLAN 0 C-2 ELEVATIONS 0 C-3 ANTENNA PLANS 0 C-3.1 RFDS & CABLE SPECIFICATIONS 0 C-4 EQUIPMENT DETAILS 0 E-1 ELECTRICAL DETAILS 0 E-2 GROUNDING PLANS 0 RECEIVED CITY OF TUKWILA 0 05/01/17 100% CONSTRUCTION JMB JUN 22 2017 04/13/17 ISSUED FOR REVIEW 90% CDE h k� 49 71��N� PERMIT CENTER THESE PLANS AND SPECIFICATIONS. AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTITY ON OTHER PROJECTS WRHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: %.• 0170 SHEET NUMBER: T-1 SCOPE OF WORK AT ANTENNA LEVEL, REMOVE (2) FXFB UNITS AND (4) TMA UNITS AND INSTALL (2) FHFB UNITS, (4) NEW TMA UNITS AND (4) DIPLEXERS. AT GROUND LEVEL, REMOVE (2) FSME AND INSTALL (2) FSMF AND (1) FXFB. APPLICABLE CODES BUILDING CODE 2015 IBC ELECTRICAL CODE 2014 NEC T • •Mobile• A AMERICAN TOWER' 41104 POWDER RIVER Engineering Services, LLC www.pewderriverdev oom LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE h k� 49 71��N� SI�Ilk SIONAL 1 THESE PLANS AND SPECIFICATIONS. AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTITY ON OTHER PROJECTS WRHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: TITLE SHEET SHEET NUMBER: T-1 GENERAL NOTES 1. THE CONTRACTOR'S SCOPE OF WORK SHALL INCLUDE ALL ITEMS DEFINED IN THE CONTRACT DOCUMENTS. THE CONTRACT DOCUMENTS INCLUDE, BUT ARE NOT LIMITED T0, THE FOLLOWING: THE CONTRACT, SPECIFICATIONS AND CONSTRUCTION DRAWINGS. 2. ALL EQUIPMENT SUPPLIED BY THE OWNER SHALL BE PICKED UP BY THE CONTRACTOR AT THE APPROPRIATE WAREHOUSE. 3. THE CONTRACTOR I5 RESPONSIBLE FOR COORDINATING ALL WORK. 4. THE CONTRACTOR SHALL PROVIDE ON-SITE SUPERVISION AT ALL TIMES WHILE THE WORK IS BEING PERFORMED AND SHALL DIRECT ALL WORK, USING HIS BEST SKILL AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES AND SEQUENCES FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. 5. THE CONTRACTOR SHALL VISIT THE JOB SITE TO REVIEW THE SCOPE OF WORK AND EXISTING JOB SITE CONDITIONS INCLUDING, BUT NOT LIMITED T0, MECHANICAL, ELECTRICAL SERVICE AND OVERALL COORDINATION. THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO SUBMITTING HIS BID. ANY DISCREPANCIES, CONFLICTS OR OMISSIONS, ETC., SHALL BE REPORTED TO THE T -MOBILE CONSTRUCTION SUPERVISOR BEFORE PROCEEDING WITH THE WORK. 6. THE CONTRACTOR SHALL PROTECT ALL AREAS FROM DAMAGE WHICH MAY OCCUR DURING CONSTRUCTION. ANY DAMAGE TO NEW AND EXISTING CONSTRUCTION, STRUCTURE, LANDSCAPING OR EQUIPMENT SHALL BE IMMEDIATELY REPAIRED OR REPLACED TO THE SATISFACTION OF THE TENANT, BUILDING OWNER OR OWNER'S REPRESENTATIVE AT THE EXPENSE OF THE CONTRACTOR. 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES, WHETHER SHOWN HEREON OR NOT, AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSES FOR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED IN CONJUNCTION WITH THE EXECUTION OF WORK. 8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE THE JOB I5 IN PROGRESS AND UNTIL THE JOB IS COMPLETED. 9. THE CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER AND TOILET FACILITIES AS REQUIRED BY THE CITY OR GOVERNING AGENCY. 10. THE CONTRACTOR AND ALL SUBORDINATE CONTRACTORS SHALL COMPLY WITH ALL LOCAL AND STATE REGULATIONS. 11. THE CONTRACTOR SHALL OBTAIN AND PAY FOR PERMITS, LICENSES AND INSPECTIONS NECESSARY FOR PERFORMANCE OF THE WORK AND INCLUDE THOSE IN THE COST OF THE WORK TO T -MOBILE. 12. FIGURED DIMENSIONS HAVE PRECEDENCE OVER DRAWING SCALE, AND DETAIL DRAWINGS HAVE PRECEDENCE OVER SMALL DRAWINGS. CHECK ACCURACY OF ALL DIMENSIONS IN THE FIELD. UNLESS SPECIFICALLY NOTED, DO NOT FABRICATE ANY MATERIALS OFF SITE, NOR DO ANY CONSTRUCTION UNTIL THE ACCURACY OF DRAWING DIMENSIONS HAVE BEEN VERIFIED AGAINST ACTUAL FIELD DIMENSIONS. 13. THE CONTRACTOR SHALL NOTIFY THE T -MOBILE CONSTRUCTION SUPERVISOR OF ANY CONFLICTS OR DISCREPANCIES IN THE CONTRACT DOCUMENTS OR FIELD CONDITIONS PRIOR TO EXECUTING THE WORK IN QUESTION. 14. THE CONTRACTOR SHALL NOTIFY THE T -MOBILE CONSTRUCTION SUPERVISOR IF DETAILS ARE CONSIDERED UNSOUND, UNSAFE, NOT WATERPROOF, OR NOT WITHIN CUSTOMARY TRADE PRACTICE. IF WORK IS PERFORMED, IT WILL BE ASSUMED THAT THERE IS NO OBJECTION TO THE DETAIL. DETAILS ARE INTENDED TO SHOW THE END RESULT OF THE DESIGN. MINOR MODIFICATIONS MAY BE REQUIRED TO SUIT JOB CONDITIONS, AND SHALL BE INCLUDED AS PART OF THE WORK. 15. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL BE VERIFIED BY THE CONTRACTOR BEFORE CONSTRUCTION. IF THEY DIFFER FROM THOSE SHOWN ON THE PLANS, THE CONTRACTOR SHALL NOTIFY THE T -MOBILE CONSTRUCTION SUPERVISOR 50 THAT MODIFICATIONS CAN BE MADE BEFORE PROCEEDING WITH THE WORK. 16. ALL SYMBOLS AND ABBREVIATIONS USED ON THE DRAWINGS ARE CONSIDERED CONSTRUCTION STANDARDS. IF THE CONTRACTOR HAS QUESTIONS REGARDING THEIR EXACT MEANING, THE T -MOBILE CONSTRUCTION SUPERVISOR SHALL BE NOTIFIED FOR CLARIFICATION BEFORE PROCEEDING WITH THE WORK. 17. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY BLOCKING, BACKING, FRAMING, HANGERS OR OTHER SUPPORT FOR ALL OTHER ITEMS REQUIRING THE SAME. 18. CITY APPROVED PLANS SHALL BE KEPT IN A PLAN BOX ANDSHALL 5 LL NOT BE USED BY WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT SAME INFORMATION. AT ALL TIMES THESE ARE TO BE UNDER THE CARE OF THE JOB SUPERINTENDENT. 19. DESIGN DRAWINGS ARE DIAGRAMMATIC ONLY AND SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION CONDITIONS WILL PERMIT. ANY ERROR, OMISSION, OR DESIGN DISCREPANCY SHALL BE BROUGHT TO THE ATTENTION OF THE T -MOBILE CONSTRUCTION SUPERVISOR FOR CLARIFICATION OR CORRECTION BEFORE CONSTRUCTION. 20. AS -GUILTS REQUIREMENTS: DO NOT USE RECORD DOCUMENTS FOR CONSTRUCTION PURPOSES. PROTECT RECORD DOCUMENTS FROM DETERIORATION AND LOSS IN A SECURE, FIRE-RESISTANT LOCATION. PROVIDE ACCESS TO RECORD DOCUMENTS FOR THE T -MOBILE CONSTRUCTION SUPERVISOR'S REFERENCE DURING NORMAL WORKING HOURS. MAINTAIN A CLEAN, UNDAMAGED SET OF BLUE OR BLACK LINE PRINTS OF CONTRACT DRAWINGS AND SHOP DRAWINGS. MARK THE SET TO SHOW THE ACTUAL INSTALLATION WHERE THE INSTALLATION VARIES SUBSTANTIALLY FROM THE WORK AS ORIGINALLY SHOWN. MARK WHICH DRAWINGS IS MOST CAPABLE OF SHOWING CONDITIONS FULLY AND ACCURATELY. WHERE SHOP DRAWINGS ARE USED, RECORD A CROSS-REFERENCE AT THE CORRESPONDING LOCATION ON THE CONTRACT DRAWINGS. GIVE PARTICULAR ATTENTION TO CONCEALED ELEMENTS THAT WOULD BE DIFFICULT TO MEASURE AND RECORD AT A LATER DATE. MARK RECORD SETS WITH RED ERASABLE PENCIL. USE OTHER COLORS TO DISTINGUISH BETWEEN VARIATIONS IN SEPARATE CATEGORIES OF THE WORK. MARK NEW INFORMATION THAT IS IMPORTANT TO THE OWNER BUT WAS NOT SHOWN ON THE CONTRACT DRAWINGS, DETAILS OR SHOP DRAWINGS. NOTE RELATED CHANGE ORDER NUMBERS WHERE APPLICABLE. NOTE RELATED RECORD DRAWING INFORMATION AND PRODUCT DATA. UPON COMPLETION OF THE WORK, SUBMIT ONE (1) COMPLETE SET OF RECORD DOCUMENTS TO THE T -MOBILE CONSTRUCTION SUPERVISOR FOR THE OWNER'S RECORDS. PART 1: GENERAL 1.1 SCOPE: CLEARING, GRUBBING, STRIPPING, EROSION CONTROL, SURVEY, LAYOUT, SUB GRADE PREPARATION, FINISH GRADING AND SECURITY FENCE, AS REQUIRED BY CONSTRUCTION DRAWINGS AND DETAIL DRAWINGS. 1.2 REFERENCES A. DEPARTMENT OF TRANSPORTATION CONSTRUCTION AND MATERIAL SPECIFICATIONS FOR THE STATE IN WHICH THE PROJECT I5 LOCATED B. ASTM (AMERICAN SOCIETY FOR TESTING AND MATERIALS) C. OSHA (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION) D. AASHTO (AMERICAN ASSOCIATION OF STATE HIGHWAY TRANSPORTATION OFFICIALS) 1 3 INSPECTION AND TESTING A. FIELD TESTING OF EARTHWORK, AGGREGATE BASE COURSE, COMPACTION, AND CONCRETE TESTING SHALL BE PERFORMED BY THE CONTRACTOR'S INDEPENDENT TESTING LAB. B. ALL WORK SHALL BE INSPECTED AND RELEASED BY THE T -MOBILE CONSTRUCTION SUPERVISOR WHO SHALL CARRY OUT THE GENERAL INSPECTION OF THE WORK WITH SPECIFIC CONCERN TO PROPER PERFORMANCE OF THE WORK AS SPECIFIED AND/OR CALLED FOR ON THE DRAWINGS. IT I5 THE CONTRACTOR'S RESPONSIBILITY TO REQUEST TIMELY INSPECTIONS PRIOR TO PROCEEDING WITH FURTHER WORK THAT WOULD MAKE PARTS OF THE WORK INACCESSIBLE OR DIFFICULT TO INSPECT. 1.4 SITE MAINTENANCE AND PROTECTION A. PROVIDE ALL NECESSARY JOB SITE MAINTENANCE FROM COMMENCEMENT OF THE WORK UNTIL COMPLETION OF THE CONTRACT. B. CONTACT THE ONE -CALL UTILITY LOCATION SERVICE PRIOR TO ANY EXCAVATING ACTIVITIES TO HAVE LOCATIONS OF UNDERGROUND UTILITIES VERIFIED. C. AVOID DAMAGE TO THE SITE INCLUDING EXISTING FACILITIES, STRUCTURES, TREES AND SHRUBS DESIGNATED TO REMAIN. TAKE PROTECTIVE MEASURES TO PREVENT EXISTING FACSIMILES THAT ARE NOT DESIGNATED FOR REMOVAL FROM BEING DAMAGED BY THE WORK. D. KEEP SITE FREE OF ALL PONDING WATER. E. PROVIDE EROSION CONTROL MEASURES IN ACCORDANCE WITH THE DEPARTMENT OF TRANSPORTATION CONSTRUCTION AND MATERIAL SPECIFICATIONS FOR THE STATE IN WHICH THE PROJECT IS LOCATED. F. PROVIDE AND MAINTAIN ALL TEMPORARY FENCING, BARRICADES, WARNING SIGNALS AND SIMILAR DEVICES NECESSARY TO PROTECT LIFE AND PROPERTY DURING THE ENTIRE PERIOD OF CONSTRUCTION. REMOVE ALL SUCH DEVICES UPON COMPLETION OF THE WORK. PART II: PRODUCTS 2.1 SUITABLE BACK FILL: EXCAVATED INORGANIC MATERIAL, COHESIVE AND NON -COHESIVE MATERIALS, INCLUDING GRAVEL, SAND, INORGANIC LEAN CLAY, GRAVEL SILT, GRAVEL CLAY, SAND CLAY, SAND SILT OR SILT CLAY MATERIAL FREE FROM FROZEN LUMPS, REFUSE, STONES OR ROCKS LARGER THAN 3 -INCHES IN ANY DIMENSION OR OTHER MATERIAL THAT MAY MAKE THE INORGANIC MATERIAL UNSUITABLE FOR BACKFILL OR FILL MATERIAL AS DETERMINED BY THE T -MOBILE CONSTRUCTION SUPERVISOR AND GEOTECHNICAL ENGINEER. 2.2 UNSUITABLE MATERIALS: TOP SOIL, HIGH AND MODERATELY PLASTIC SILTS AND CLAY, MATERIAL CONTAINING REFUSE, FROZEN LUMPS, DEMOLISHED BITUMINOUS MATERIAL, VEGETATIVE MATTER, WOOD, STONES IN EXCESS OF 3 -INCHES IN ANY DIMENSION AND DEBRIS AS DETERMINED BY THE CONSTRUCTION SUPERVISOR AND T -MOBILE GEOTECHNICAL ENGINEER. TYPICALLY, THESE WILL BE SOILS CLASSIFIED AS PT, MH, CH, OH, ML OR OL. 2.3 GEOTEXTILE FABRIC' MIRAFI 500X OR APPROVED EQUIVALENT 2.4 PLASTIC MARKING TAPE: SHALL BE ACID- AND ALKALI -RESISTANT POLYETHYLENE FILM, SPECIFICALLY MANUFACTURED FOR MARKING AND LOCATING UNDERGROUND UTILITIES, 6 -INCHES WIDE WITH A MINIMUM THICKNESS OF 0.004 -INCH. TAPE SHALL HAVE MINIMUM STRENGTH OF 1500 PSI IN BOTH DIRECTIONS AND MANUFACTURED WITH INTEGRAL WIRES,FOIL BACKING OR OTHER MEANS TO ENABLE DETECTION BY A METAL DETECTOR WHEN BURIED UP TO 3 FEET DEEP. THE METALLIC CORE OF THE TAPE SHALL BE ENCASED IN A PROTECTIVE JACKET OR PROVIDED WITH OTHER MEANS TO PROTECT IT FROM CORROSION. TAPE COLOR SHALL BE RED FOR ELECTRIC UTILITIES AND ORANGE FOR TELECOMMUNICATION UTILITIES. 2.5 SECURITY FENCE A. PROVIDE AND INSTALL THE GALVANIZED FENCE WITH ASSOCIATED POSTS, RAILS, BRACES, FABRIC, TERMINAL POST, GATES, DROP BAR AND BARBED WIRE. USE APPLICABLE PROVISIONS OF ASTM FOR MATERIALS. B. FABRIC SHALL BE HEAVY GALVANIZED CHAIN LINK FENCE, CONFORMING TO ASTM A392 2 -INCH MESH 9 GAUGE WIRE (0.148 INCHES IN DIAMETER) WITH THE TOP AND BOTTOM SELVAGES TWISTED AND BARBED. C. POSTS 1. LINE POST FOR FABRIC UP TO 8 FEET HIGH SHALL BE 2-3/8 INCH 0.0. 2. END CORNER, PULL POST AND GATE POST SHALL BE 2-7/8 INCH 0.0. ALL POSTS SHALL BE SCHEDULE 40 GALVANIZED STEEL PIPE IN ACCORDANCE WITH FOR FENCE FEET HIGH,SIZE POST ACCORDING ASTM .1 A 1 A570 AND A525 R OVER 8 2D TO MANUFACTURER'S RECOMMENDATIONS. D. TOP RAILS SHALL CONFORM TO 1-1/4 INCH (1.66 INCH 0.0.), SCHEDULE 40 GALVANIZED STEEL PIPE IN ACCORDANCE WITH ASTM4 Al2D. E. TENSION WIRE SHALL BE 7 GAUGE U.S. STEEL WIRE GALVANIZED IN ACCORDANCE WITH ASTM 5116, COATING CLASS III. F. BRACE BANDS, TENSION BANDS AND TENSION BARS SHALL BE FABRICATED OF 1/8 INCH BY 7/B INCH GALVANIZED STEEL WITH GALVANIZED STEEL CARRIAGE BOLTS AND NUTS IN ACCORDANCE WITH ASTM4 A123. TENSION BARS SHALL BE 1/4 INCH BY 3/4 INCH GALVANIZED STEEL BAR IN ACCORDANCE WITH ASTM A153. G. FABRIC TIES SHALL BE CLASS I GALVANIZED STEEL WIRE NO LESS THAN 9 GAUGE. H. POST TOPS SHALL BE PRESSED STEEL OR MALLEABLE IRON AND SHALL BE GALVANIZED PER ASTM A15J. I. BARBED WIRE SHALL CONSIST OF DOUBLE STRANDED 12 1/2 GAUGE WIRE ASTM A121, CLASS 3 WITH 4 -POINT BARBS SPACED 5 INCHES APART. THE TOP 1 FOOT OF THE FENCE SHALL CONSIST OF 3 STRANDS OF BARBED WIRE ATTACHED TO 45 DEGREE ANGLE, HEAVY -PRESSED ARMS CAPABLE OF WITHSTANDING WITHOUT FAILURE 250 POUNDS DOWNWARD PULL AT THE OUTERMOST END OF THE ARM J. GATE MATERIALS, SUCH AS FABRIC, BOLTS, NUTS, TENSION BARS AND BARBED WIRE SHALL BE CONSISTENT WITH FENCE MATERIALS. PART III: EXECUTION 3.1 GENERAL A. BEFORE STARTING GENERAL SITE PREPARATION ACTIVITIES, INSTALL EROSION AND SEDIMENT CONTROL MEASURES. THE WORK AREA SHALL BE CONSTRUCTED AND MAINTAINED IN SUCH CONDITION THAT IN THE EVENT OF RAIN THE SITE WILL BE WELL DRAINED AT ALL TIMES. 8. PERFORM ALL SURVEY, LAYOUT, STAKING AND MARKING TO ESTABLISH AND MAINTAIN ALL LINES, GRADES, ELEVATIONS AND BENCHMARKS NEEDED FOR EXECUTION OF THE WORK. C. CLEAR AND GRUB THE AREA WITHIN THE LIMITS OF THE SITE AND ONLY THE IMMEDIATE SURROUNDINGS NECESSARY TO COMPLETE THE WORK. REMOVE TREES, BRUSH, STUMPS, RUBBISH AND OTHER DEBRIS AND VEGETATION RESTING ON OR PROTRUDING THROUGH THE SURFACE OF THE SITE AREA TO BE CLEARED AND GRUBBED. 1. REMOVE THE FOLLOWING MATERIALS TO A DEPTH OF NO LESS THAN 12 -INCHES BELOW THE ORIGINAL GROUND SURFACE: ROOTS, STUMPS AND OTHER DEBRIS, BRUSH AND REFUSE EMBEDDED IN OR PROTRUDING THROUGH THE GROUND SURFACE. RAKE, DISK OR PLOW THE AREA TO A DEPTH F NO LESS THAN 6 -INCHES ANDREMOVE 0 E E UP TO A DEPTH OF 12 -INCHES All ROOTS AND OTHER DEBRIS THEREBY EXPOSED. 2. REMOVE TOPSOIL MATERIALS COMPLETELY FROM THE SURFACE UNTIL THE SOIL NO LONGER MEETS THE DEFINITION OF TOPSOIL. AVOID MIXING TOPSOIL WITH SUBSOIL OR OTHER EXCAVATED MATERIALS. TOPSOIL SHALL BE STOCKPILED E L LED SEPARATELY FOR REUSE, AS DIRECTED BY THE CONSTRUCTION SUPERVISOR. EXCEPT WHERE EXCAVATION TO GREATER DEPTH IS INDICATED 3.EATE FILL DEPRESSIONS RESULTING FROM CLEARING, GRUBBING AND DEMOLITION COMPLETELY WITH SUITABLE FILL. D. REMOVE FROM THE SITE AND DISPOSE IN AN AUTHORIZED LANDFILL All DEBRIS RESULTING FROM CLEARING AND GRUBBING OPERATIONS. BURNING IS NOT PERMITTED. E. PRIOR TO EXCAVATING, THOROUGHLY EXAMINE THE AREA TO BE EXCAVATED AND/OR TRENCHED TO VERIFY THE LOCATIONS OF FEATURES INDICATED ON THE DRAWINGS, AND ASCERTAIN THE EXISTENCE AND LOCATION OF ANY STRUCTURE, UNDERGROUND STRUCTURE, CULVERT, STREAM CROSSING OR OTHER ITEM NOT SHOWN THAT MIGHT AFFECT OR INTERFERE WITH THE NEW CONSTRUCTION. NOTIFY THE T -MOBILE CONSTRUCTION SUPERVISOR OF ANY OBSTRUCTIONS THAT WILL PREVENT ACCOMPLISHMENT OF THE WORK AS INDICATED ON THE DRAWINGS. F. SEPARATE AND STOCKPILE All EXCAVATED MATERIALS SUITABLE FOR BACK FILL. ALL EXCESS EXCAVATED AND UNSUITABLE MATERIALS SHALL BE DISPOSED OF IN AN AREA DESIGNATED BY THE T -MOBILE CONSTRUCTION SUPERVISOR. (UNSUITABLE MATERIAL MAY BE REQUIRED TO BE REMOVED FROM THE SITE.) 3.2 STRUCTURAL EXCAVATION A. FOUNDATION EXCAVATIONS SHALL BE CUT TO FIRM MATERIAL HAVING A SAFE BEARING VALUE OF 3000 PSF AND SHALL BE FREE OF ALL LOOSE AND WET MATERIALS. IF THE BOTTOM OF THE EXCAVATION IS NOT FIRM AND STABLE, OVER -EXCAVATE AN ADDITIONAL 12 INCHES, COMPACT SUB -GRADE AND FILL WITH 12 INCHES OF SELECT STRUCTURAL FILL. B. AFTER EXCAVATION, THE EXPOSED SOILS SHALL BE INSPECTED AND TESTED AND ANY UNSUITABLE DEPOSITS REMOVED AS DIRECTED TO REACH SUITABLE BEARING SOIL ALL OVER -EXCAVATED AREAS SHALL. BE BACK FILLED WITH SELECT STRUCTURAL FILL OR WITH LEAN CONCRETE FILL TO THE ELEVATION OF THE BOTTOM OF FOOTING OR FOUNDATION AS INDICATED ON THE DRAWINGS. C. PRIOR TO PLACEMENT OF CONC. FOUNDATIONS, THE SURFACE ON WHICH THE CONCRETE IS TO 8E PLACED SHALL. BE COMPACTED TO A MINIMUM OF 95% OF THE MODIFIED PROCTOR DENSITY BY THE MODIFIED PROCTOR TEST, ASTM4 D1557. D. NO FOUNDATIONS OR STRUCTURES SHALL BE CONSTRUCTED UNTIL THE BASE MATERIALS HAVE BEEN INSPECTED BY THE T -MOBILE CONSTRUCTION SUPERVISOR. 3.3 STRUCTURAL FILL: All COMPACTED FILL SHALL BE PLACED IN LAYERS NOT EXCEEDING A LOOSE THICKNESS AND COMPACTED TO A MINIMUM DENSITY OF 95% OF THE MODIFIED PROCTOR DENSITY OBTAINED IN ACCORDANCE WITH ASTM4 D-1557. 3.4 BACK FILL AS SOON AS PRACTICAL AFTER COMPLETING CONSTRUCTION OF THE RELATED STRUCTURE, INCLUDING EXPIRATION OF THE SPECIFIED MINIMUM CURING PERIOD FOR CAST -IN-PLACE CONCRETE, BACKFILL THE EXCAVATION WITH APPROVED MATERIAL TO RESTORE THE REQUIRED FINISH GRADE. 1. PRIOR TO PLACING BACKFILL AROUND STRUCTURES, ALL FORMS SHALL HAVE BEEN REMOVED AND THE EXCAVATION CLEANED OF ALL TRASH, DEBRIS AND UNSUITABLE MATERIALS. 2. BACK FILL BY PLACING AND COMPACTING SUITABLE BACKFILL MATERIAL OR SELECT GRANULAR BACKFILL MATERIAL, WHEN REQUIRED, IN UNIFORM HORIZONTAL LAYERS OF NO GREATER THAN 8 -INCH LOOSE THICKNESS. WHERE HAND -OPERATED COMPACTORS ARE USED, THE FILL MATERIALS SHALL BE PLACED IN LIFTS NOT TO EXCEED FOUR INCHES IN LOOSE DEPTH. 3. WHENEVER THE DENSITY TESTS INDICATE THAT THE CONTRACTOR HAS NOT OBTAINED THE SPECIFIED DENSITY, THE SUCCEEDING LAYER SHALL NOT BE PLACED UNTIL THE SPECIFICATION REQUIREMENTS ARE MET UNLESS OTHERWISE AUTHORIZED BY THE GEOTECHNICAL ENGINEER. THE CONTRACTOR SHALL TAKE WHATEVER APPROPRIATE ACTION IS NECESSARY, SUCH AS DISKING AND DRYING, ADDING WATER OR INCREASING THE COMPACTIVE EFFORT. B. THOROUGHLY COMPACT EACH LAYER OF BACKFILL TO A MINIMUM OF 90% OF THE MAXIMUM DRY DENSITY AS PROVIDED BY THE MODIFIED PROCTOR TEST C. DO NOT PLACE UNTIL THE CONCRETE HAS CURED FOR AT LEAST 7 DAYS OR COMPRESSIVE STRENGTH TESTS INDICATE THAT THE CONCRETE HAS ACHIEVED MORE THAN BOX OF ITS SPECIFIED 28 DAY COMPRESSIVE STRENGTH. 3.5 TRENCH EXCAVATION A. UTILITY TRENCHES SHALL BE EXCAVATED TO THE LINES AND GRADES SHOWN ON THE DRAWINGS OR AS DIRECTED BY THE T -MOBILE CONSTRUCTION SUPERVISOR. PROVIDE SHORING, SHEETING AND BRACING AS REQUIRED TO PREVENT CAVING OR SLOUGHING OF THE TRENCH WAILS. B. THE TRENCH WIDTH EXTENDS A MINIMUM OF 6 INCHES BEYOND EACH OUTSIDE EDGE OF THE CONDUIT OR OUTERMOST CONDUIT, WHICHEVER IS APPLICABLE. C. WHEN SOFT, YIELDING OR OTHERWISE UNSTABLE SOIL CONDITIONS ARE ENCOUNTERED AT THE REQUIRED TRENCH BOTTOM ELEVATION, OVER -EXCAVATE THE TRENCH TO A DEPTH OF NO LESS THAN 12 INCHES BELOW THE REQUIRED ELEVATION AND BACKFILL WITH GRANULAR BEDDING MATERIAL. 3.6 TRENCH BACK FILL A. PROVIDE GRANULAR BEDDING MATERIAL IN ACCORDANCE WITH THE SPECIFICATIONS, DRAWINGS AND THE UTILITY REQUIREMENTS. B. NOTIFY THE T -MOBILE CONSTRUCTION SUPERVISOR 24 HOURS IN ADVANCE OF BACK FILLING C. CONDUCT UTILITY CHECK TESTS BEFORE BACK FILLING BACK FILL AND COMPACT TRENCH BEFORE ACCEPTANCE TESTING. D. PLACE GRANULAR TRENCH BACKFILL UNIFORMLY ON BOTH SIDES OF THE CONDUITS IN 6 -INCH UNCOMPACTED LIFTS UNTIL 12 INCHES OVER THE CONDUITS. SOLIDLY RAM AND TAMP BACKFILL INTO SPACES AROUND THE CONDUITS. E. PROTECT CONDUIT FROM LATERAL MOVEMENT, DAMAGE FROM IMPACT OR UNBALANCED LOADING. F. ABOVE THE CONDUIT EMBEDMENT ZONE, PLACE AND COMPACT SATISFACTORY BACKFILL MATERIAL IN 9 -INCH MAXIMUM LOOSE THICKNESS LIFTS TO RESTORE THE REQUIRED FINISHED SURFACE GRADE. G. COMPACT FINAL TRENCH BACKFILL TO A DENSITY EQUAL TO OR GREATER THAN THAT OF THE EXISTING UNDISTURBED MATERIAL IMMEDIATELY ADJACENT TO THE TRENCH BUT NO LESS THAN A MINIMUM OF 95% OF THE MAXIMUM DRY DENSITY A5 PROVIDED BY THE MODIFIED PROCTOR TEST, ASTM D1557 3.7 AGGREGATE ACCESS ROAD AND SITE A. CLEAR, GRUB, STRIP AND EXCAVATE FOR THE ACCESS ROAD AND TOWER COMPOUND TO THE LINES AND GRADES INDICATED ON THE DRAWINGS. SCARIFY TO A DEPTH OF 6 INCHES AND PROOF -ROLL ALL HOLES, RUTS, SOFT PLACES AND OTHER DEFECTS SHALL BE CORRECTED. B. THE ENTIRE SUB GRADE SHALL BE COMPACTED TO NOT LESS THAN 95:2:03 THE MAXIMUM DRY DENSITY AS PROVIDED BY THE MODIFIED PROCTOR TEST, ASTM D 1557. C. AFTER PREPARATION OF THE SUB GRADE IS COMPLETED, THE GEOTEXTILE FABRIC SHALL BE INSTALLED TO THE LIMITS INDICATED ON THE DRAWINGS BY ROLLING THE FABRIC OUT LONGITUDINALLY ALONG THE ROADWAY OR SITE. THE FABRIC SHALL NOT BE DRAGGED ACROSS THE SUB GRADE PLACE THE ENTIRE ROLL IN A SINGLE OPERATION, ROLLING THE MATERIAL AS SMOOTHLY AS POSSIBLE. 1. OVERLAPS PARALLEL TO THE ROADWAY AND SITE WILL BE PERMITTED AT THE CENTERLINE AND AT LOCATIONS BEYOND THE ROADWAY OR SITE SURFACE WIDTH (I.E., WITHIN THE SHOULDER WIDTH) ONLY. NO LONGITUDINAL OVERLAPS SHALL BE LOCATED BETWEEN THE CENTERLINE AND THE SHOULDER. PARALLEL OVERLAPS SHALL BE A MINIMUM OF 3 FEET WIDE. 2. TRANSVERSE (PERPENDICULAR TO THE ROADWAY) OVERLAPS AT THE END OF A ROLL SHALL OVERLAP IN THE DIRECTION OF THE AGGREGATE PLACEMENT (PREVIOUS ROLL ON TOP) AND SHALL HAVE A MINIMUM LENGTH OF 3 FEET. 3. ALL OVERLAPS SHALL. BE PINNED WITH STAPLES OR NAILS BETWEEN 10 AND 12 INCHES LONG TO INSURE STABLE POSITIONING DURING PLACEMENT OF AGGREGATE. PIN LONGITUDINAL SEAMS AT 25 -FOOT CENTERS AND TRANSVERSE SEAMS EVERY 5 FEET ON CENTER. D. THE AGGREGATE SUB BASE, BASE AND SURFACE COURSES SHALL BE CONSTRUCTED IN LAYERS NOT MORE THAN 4 INCHES (COMPACTED) THICKNESS. AGGREGATE TO BE PLACED ON GEOTEXTI LE FABRIC SHALL BE END -DUMPED ON THE FABRIC FROM THE FREEF THE END 0 T E FABRIC OR OVER PREVIOUSLY PLACED AGGREGATE. AT NO TIME SHALL EQUIPMENT, EITHER DUMPING THE AGGREGATE OR GRADING THE AGGREGATE BE PERMITTED ON THE ROADWAY OR COMPOUND WITH LESS THAN 8 INCHES OF MATERIAL COVERING THE FABRIC. E. THE AGGREGATE SUB BASE AND BASE SHALL BE IMMEDIATELY COMPACTED TO NOT LESS THAN 95% OF THE MAXIMUM DRY DENSITY AS PROVIDED BY THE MODIFIED PROCTOR TEST, ASTM4 D 1557. 3.8 FINISH GRADING A. PERFORM ALL FINISHED GRADING TO PROVIDE SMOOTH, EVEN SURFACE AND SUBSURFACE DRAINAGE OF THE ENTIRE AREA WITHIN THE LIMITS OF CONSTRUCTION. GRADING SHALL BE COMPATIBLE WITH ALL SURROUNDING TOPOGRAPHY AND STRUCTURES. 8. UTILIZE SATISFACTORY FILL MATERIALS RESULTING FROM THE EXCAVATION WORK IN THE CONSTRUCTION OF FILLS, EMBANKMENTS AND FOR THE REPLACEMENT OF REMOVED UNSUITABLE MATERIALS. C. REPAIR All ACCESS ROADS AND SURROUNDING AREAS USED DURING THE COURSE OF THIS WORK TO THEIR ORIGINAL CONDITION. 3.9 SECURITY FENCE A. THE BOTTOM OF THE FENCE SHALL BE 2 INCHES BELOW THE TOP OF THE COMPOUND GRAVEL IF THE SITE CROSSES FEATURES SUCH AS DRAINAGE DITCHES, ETC., THE FENCE SHALL SPAN THE DEPRESSION. CLOSE THE SPACE BELOW THE BOTTOM OF THE FENCE WITH EXTRA FENCE FABRIC OR BARBED WIRE AS DIRECTED BY THE T -MOBILE CONSTRUCTION SUPERVISOR. PRIOR TO PLACING COMPONENTS SUCH AS FABRIC, RAILS, TENSION WIRE AND GATES, ENSURE THAT THE CONCRETE POST FOUNDATION HAS REACHED AT LEAST 75% OF ITS DESIGN STRENGTH OR HAS CURED A MINIMUM OF 7 DAYS AFTER SETTING THE POST. B. FURNISH GATES WITH NECESSARY FITTINGS AND HARDWARE. HINGES SHALL ALLOW SWING GATES TO SWING 180 DEGREES. PLUNGER BARS SHALL HAVE TOP, BOTTOM AND MIDDLE LOCKING POINTS WITH THE MIDDLE POINT ARRANGED FOR PADLOCKING. GATES SHALL HAVE KEEPERS ON EACH LEAF THA e OMATICALLY WHEN THE GATE IS SWUNG OPEN. 1 N.•)9p11 1A,. IN SHE FIELD WITH METHODS AND TECHNIQUES AS RERlEVII�:,i .. YV N,. 41 D R. CODE COMPLIANCE APPROVED F RECEIVFID CITY OF TUKWILA jUN222011 PERMIT CENTER 21117 City of Tukwila BUILDING DIVISION GENERAL NOTES SCALE NTS 1 T • •Mobile • A AMERICAN TOWER® /040 POWDER RIVER Engineering Services, LLC www.powderriverdev cam LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE • (;.f r,iivinslIv ÷, A. ' 9A co i . I' 4 fi49671 .) � G IS- t. it $IOM AL ilk THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE. ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTITY ON OTHER PROJECTS WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: GENERAL NOTES SHEET NUMBER: GN -1 PROJECT SPECIFICATION 16000 (ELECTRICAL) PART 1 GENERAL 1.1 SCOPE' THIS SPECIFICATION DESCRIBES THE MINIMUM REQUIREMENT FOR INSTALLATION OF ALL ELECTRICAL SYSTEMS. 1.2 REFERENCES: THE PUBLICATIONS LISTED BELOW FORM PART OF THIS SPECIFICATION. EACH PUBLICATION SHALL BE THE LATEST REVISION AND ADDENDUM IN EFFECT ON THE DATE THIS SPECIFICATION IS ISSUED FOR CONSTRUCTION, UNLESS NOTED OTHERWISE. EXCEPT AS MODIFIED BY THE REQUIREMENTS SPECIFIED HEREIN, OR THE DETAILS OF THE DRAWINGS, WORK INCLUDED IN THIS SPECIFICATION SHALL CONFORM TO THE APPLICABLE PROVISIONS OF THESE PUBLICATIONS. A. ANSI (AMERICAN NATIONAL STANDARDS INSTITUTE) B. NESC (NATIONAL ELECTRICAL SAFETY CODE), LATEST EDITION C. NEC (NATIONAL ELECTRICAL CODE), LATEST EDITION D. NFPA 70 (NATIONAL FIRE PROTECTION ASSOCIATION) E. OSHA (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION), INCLUDING ALL APPLICABLE AMENDMENTS F. U.L. (UNDERWRITERS LABORATORIES) 1.3 SYSTEM DESCRIPTION A. DESIGN REQUIREMENTS: THE CONTRACTOR SHALL INSTALL UNDERGROUND ELECTRICAL AND TELEPHONE CONDUITS AND CABLE AS SPECIFIED HEREIN AND AS SHOWN ON THE DRAWINGS. B. PERFORMANCE REQUIREMENTS: WHEN FINISHED, WORK SHALL BE IN A COMPLETE AND UNDAMAGED STATE, AS REQUIRED IN THE CONTRACT DOCUMENTS. PART II: PRODUCTS 2.1 GENERAL A. ITEMSHA FIRST-CLASS S LL BE NEW AND SHALL BE INSTALLED ONLY IF IN CONDITION. B. SUBSTITUTIONS FOR MATERIAL WILL BE PERMITTED ONLY BY WRITTEN APPROVAL OF THE T -MOBILE CONSTRUCTION SUPERVISOR. 2.2 MATERIALS: THE CONTRACTOR SHALL PROVIDE ALL MATERIAL EXCEPT AS SPECIFIED IN THE CONTRACT DOCUMENTS. ALL MATERIAL SHALL BE APPROVED AND LISTED BY OR BEAR THE U.L. LABEL, AND WILL COMPLY WITH ANSI, IEEE AND NEMA STANDARDS WHERE APPLICABLE. A. CONDUITS: 1. ALL UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC, SIZED AS SHOWN ON THE CONSTRUCTION DRAWINGS. 2. ALL EXTERIOR ABOVEGROUND CONDUIT SHALL BE PER LOCAL CODE REQUIREMENTS. 3. ALL INTERIOR CONDUIT SHALL BE EMT WITH COMPRESSION -TYPE FITTINGS. 4. LIQUID -TIGHT FLEXIBLE METALLIC CONDUIT SHALL BE USED FOR OUTDOOR LOCATIONS WHERE FLEXIBLE CONNECTION IS REQUIRED. B. CABLES CONDUCTORS FOR GENERAL WIRING SHALL BE NEC STANDARD ANNEALED COPPER WIRE WITH NEC 600 VOLT INSULATION. 1. #B AND LARGER -STRANDED TYPE, THHN OR THWN 2. #10 AND SMALLER -SOLID TYPE THHN OR THWN 3. CONDUCTORS IN CONDUIT IN OR ADJACENT TO HIGH HEAT SOURCE SHALL BE TYPE XHHW 4. CONDUCTORS IN CONDUITS ABOVE ROOF, ON TOP OF ROOF OR INSIDE BUILT-UP ROOFING MATERIAL SHALL BE TYPE XHHW C. CONVENIENCE OUTLET, UNLESS NOTED OTHERWISE, SURFACE -MOUNTED OUTLETS FOR EXTERIOR LOCATIONS SHALL BE FERALOY, CAD/ZINC ELECTROPLATED WITH THREADED HUBS OR CONDUIT ENTRANCES DRILLED AND TAPPED. ALL COVERS SHALL BE SELF-CLOSING AND GASKETED. SURFACE MOUNTED OUTLETS FOR INTERIOR LOCATIONS SHALL BE GALVANIZED, PRESSED STEEL WITH COVER PLATE, SIERRA PLASTIC STYLE, IVORY COLOR. D. COAXIAL CABLE SUPPORTS 1. ALL WAVE GUIDE SUPPORTS SHALL BE MANUFACTURED TO MEET ALL COAX MINIMUM BENDING REQUIREMENTS WAVE GUIDES, AND B1587 FOR 6 WAVE GUIDES. SUPPORTS SHALL BE PROVIDED 3'-0" ON CENTERS. PART III: EXECUTION 3.1 PREPARATION A. BEFORE LAYING OUT WORK, EXERCISE PROPER PRECAUTION TO VERIFY EACH MEASUREMENT. B. USE EXTREME CAUTION BEFORE EXCAVATING IN EXISTING AREAS TO LOCATE EXISTING UNDERGROUND SERVICES. 3.2 INSPECTION A. A VISUAL CHECK OF ELECTRICAL AND TELEPHONE CABLES, CONDUITS AND OTHER ITEMS SHALL BE MADE BY A T -MOBILE CONSTRUCTION SUPERVISOR BEFORE THESE ITEMS ARE PERMANENTLY INSTALLED. B. THE CONTRACTOR SHALL NOTIFY THE T -MOBILE CONSTRUCTION SUPERVISOR 24 HOURS PRIOR TO TRENCH BACK FILL 3.3 INSTALLATION A. TRENCHING, BACK FILLING, BEDDING AND COMPACTING SHALL COMPLY WITH SITE WORK SPECIFICATIONS. B. DIG TRENCHES TO THE REQUIRED DEPTH AS SHOWN ON THE DRAWINGS WITHOUT POCKETS OR DIPS. REMOVE LARGE STONES FROM THE BOTTOM OF THE TRENCH AND FIRMLY TAMP LOOSE FILL IN THE BOTTOM BEFORE CONDUIT IS LAID. C. INSTALL UNDERGROUND CONDUIT WITH A MINIMUM 3 -INCH TO 100 -FOOT SLOPE OR TO A SLOPE SHOWN ON THE DRAWINGS. D. UNLESS SHOWN OTHERWISE ON THE DRAWINGS, TERMINATE AND CAP ALL STUB -UPS 12 INCHES ABOVE FINISHED GRADE ELEVATION. E. WHEREVER CONDUITS CROSS UNDER ROADWAYS, USE GALVANIZED RIGID STEEL CONDUITS IN ALL CASES, EXTENDING 5 FEET BEYOND THE EDGE OF THE ROAD BED. MINIMUM DEPTH FOR CONDUIT SHALL BE 4 FEET BELOW ROADWAY GRADE. F. MARK UNDERGROUND CONDUITS WITH A 6 -INCH WIDE RED POLYETHYLENE TAPE BURIED 6 INCHES UNDER THE SURFACE DIRECTLY OVER THE CONDUITS. MARK THE TAPE THUS: CAUTION -BURIED ELECTRICAL CABLE. G. FOR SEALING CONDUITS, USE ONLY NON -THERMOPLASTIC COMPOUNDS SUCH AS J.M. DUXSEAL, OR AN APPROVED SUBSTITUTE. THE COMPOUND SHALL HAVE NO EFFECT ON RUBBER OR RUBBER -LIKE INSULATIONS, LEAD, ALUMINUM OR FERROUS ALLOYS; IT SHALL BE INSOLUBLE IN WATER AND WITHSTAND MAXIMUM TEMPERATURE RANGES OF THE LOCALITY. H. COAXIAL - REFER TO NOKIA ANTENNA AND COAXIAL CABLE INSULATION PROCEDURES. I. ANTENNA - REFER TO NOKIA ANTENNA AND COAXIAL CABLE INSULATION PROCEDURES. J. LNA/MHA - REFER TO NOKIA ANTENNA AND COAXIAL CABLE INSULATION PROCEDURES. END OF ELECTRICAL SPECIFICATIONS PROJECT SPECIFICATION 16670 (GROUNDING) PART 1: GENERAL 1.1 SCOPE A. THIS SPECIFICATION PRESCRIBES THE REQUIREMENTS FOR FURNISHING, INSTALLATION AND TESTING OF THE GROUNDING CABLE, CONNECTORS AND ASSOCIATED COMPONENTS AS INDICATED ON THE DRAWINGS. 8. APPLICATIONS OF ELECTRICAL GROUNDING AND BONDING WORK SPECIFIED IN THIS SPECIFICATION INCLUDE THE FOLLOWING: 1. FENCE AND GATE POSTS 2. ELECTRICAL POWER SYSTEMS 3. GROUNDING ELECTRODES 4. GROUND BUS BAR 5. SERVICE EQUIPMENT 6. ENCLOSURES 7. MONOPOLE/LATTICE TOWER B. ICE BRIDGE 1.2 REFERENCES: THE PUBLICATIONS LISTED BELOW FORM PART OF THIS SPECIFICATION. EACH PUBLICATION SHALL BE THE LATEST REVISION AND ADDENDUM IN EFFECT ON THE DATE THIS SPECIFICATION IS ISSUED FOR CONSTRUCTION, UNLESS NOTED OTHERWISE. EXCEPT AS MODIFIED BY THE REQUIREMENTS SPECIFIED HEREIN, OR THE DETAILS OF THE DRAWINGS, WORK INCLUDED IN THIS SPECIFICATION SHALL CONFORM TO THE APPLICABLE PROVISIONS OF THESE PUBLICATIONS. A. ANSI AMERICAN NATIONAL STANDARDS INSTITUTE) B. IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS) C. NEC (NATIONAL ELECTRICAL CODE), LATEST EDITION D. NEMA (NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION) E. NESC (NATIONAL ELECTRICAL SAFETY CODE), LATEST EDITION F. OSHA (OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION) G. U.L. (UNDERWRITERS LABORATORIES) H. APPLICABLE LOCAL CODES AND ORDINANCES PART II' PRODUCTS 2.1 MATERIALS' EXCEPT AS OTHERWISE INDICATED, PROVIDE ELECTRICAL GROUNDING AND BONDING SYSTEMS INDICATED; WITH ASSEMBLY OF MATERIAL, INCLUDING, BUT NOT LIMITED T0, GROUNDING ELECTRODES, BONDING JUMPER AND ADDITIONAL ACCESSORIES NEEDED FOR A COMPLETE INSTALLATION. WHERE MORE THAN ONE TYPE COMPONENT PRODUCT MEETS INDICATED REQUIREMENTS, SELECTION IS INSTALLER'S OPTION. WHERE MATERIALS OR COMPONENTS ARE NOT INDICATED, PROVIDE PRODUCTS WHICH COMPLY WITH NEC, U.L. AND IEEE REQUIREMENTS AND WITH ESTABLISHED INDUSTRY STANDARDS FOR THOSE APPLICATIONS INDICATED. A. GROUNDING 1. THE EQUIPMENT SHALL BE GROUNDED AS FOLLOWS, AS SHOWN ON THE DRAWINGS AND IN COMPLIANCE WITH NEC ARTICLE 250 AND STATE AND LOCAL CODES. 2. GROUND RODS AND QUANTITY SHOWN ON THE DRAWINGS ARE DIAGRAMMATIC. THE CONTRACTOR SHALL PERFORM A GROUND -RESISTANCE -TO -EARTH TEST. SHOULD THE INSTALLATION HAVE A RESISTANCE OF 5 OHMS OR MORE, CONTRACTOR SHALL INSTALL MORE GROUND RODS AS NECESSARY SO THAT THE OVERALL GROUND -TO -EARTH RESISTANCE IS LESS THAN 5 OHMS. 3. INSTALL ELECTRICAL GROUNDING AND BONDING SYSTEMS AS INDICATED, IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, NEC'S "STANDARD OF INSTALLATION," AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES TO ENSURE THAT PRODUCTS COMPLY WITH REQUIREMENTS. 4. COORDINATE WITH OTHER ELECTRICAL WORK AS NECESSARY TO INTERFACE INSTALLATION OF ELECTRICAL GROUNDING AND BONDING SYSTEMS. 5. INSTALL GROUND CONDUCTORS A MINIMUM OF 36 INCHES BELOW FINISHED GRADE WHICH ENCIRCLES THE TOWER AND EQUIPMENT AND ARE CONNECTED TO EACH DRIVEN GROUND ROD. GROUND TRENCH SHALL 8E AT LEAST 24 INCHES AWAY FROM FOUNDATIONS. 6. TIGHTEN GROUNDING AND BONDING CONNECTORS, INCLUDING SCREWS AND BOLTS, IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED TORQUE TIGHTENING VALUE FOR CONNECTORS AND BOLTS. WHERE MANUFACTURER'S TORQUING REQUIREMENTS ARE NOT INDICATED, TIGHTEN CONNECTIONS TO COMPLY WITH TIGHTENING TORQUE VALUE SPECIFIED IN U.L. 486A TO ASSURE PERMANENT AND EFFECTIVE GROUNDING. 7. APPLY CORROSION -RESISTANT FINISH (60-05) TO FIELD -CONNECTIONS, AT COPPER GROUND BARS AND PLACES WHERE FACTORY APPLIED PROTECTIVE COATING HAVE BEEN DESTROYED, WHICH ARE SUBJECTED TO CORROSIVE AND/OR OXIDATION PROCESS. 8. ON EXISTING LATTICE TOWERS, WATER TOWERS AND ROOF TOPS WHEN A NEW GROUNDING SYSTEM I5 INSTALLED, THE CONTRACTOR SHALL TIE THE NEW GROUND SYSTEM TO THE EXISTING WATER TOWER, LATTICE TOWER STRUCTURAL STEEL OR BUILDING STRUCTURAL STEEL AS THE CASE MAY BE AT LEAST AT ONE LOCATION SO THAT THEY ARE AT THE SAME POTENTIAL. B. GROUND RODS 1. GROUND RODS SHALL BE 5/8" DIAMETER 8'-0" LONG, COPPER CLAD DRIVEN ROD(S). 2. GROUND ROD(S) SHALL BE LOCATED AT THE PERIMETER OF EQUIPMENT AS TO CREATE A GROUND RING AS SHOWN ON THE DRAWINGS. 3. GROUND ROD(S) SHALL BE SPACED AT A MINIMUM SPACING OF 8'-0" AND A MAXIMUM SPACING OF 10'-0". 4. GROUND RODS SHELL BE BURIED BELOW THE FROSTLINE. AT NO TIME SHALL THIS DEPTH BE LESS THAN 18" BELOW FINISHED GRADE. 5. GROUND RODS WHICH CANNOT BE DRIVEN STRAIGHT DOWN THE ENTIRE (10) FEET, SHALL BE DRIVEN AT AN ANGLE NOT GRATER THAN 45 DEGREES (NEC 250-83 AND 250-84). 6. GROUND ROD LOCATIONS SHALL 8E NOTED ON THE AS -BUILT DRAWING COMPLETE WITH DIMENSIONS. 7. PROVIDE GROUND TEST WELLS AS SHOWN ON THE CONSTRUCTION DRAWINGS. C. GROUND CONDUCTOR 1. ALL DIRECT BURIED GROUND CONDUCTORS SHALL BE TINNED SOLID (#2 AWG) WIRE. BURIED GROUND CONDUCTOR SHALL BE INSTALLED AT MINIMUM DEPTH OF 36" BELOW GRADE. 2. ALL SUB GRADE GROUND CONNECTIONS SHALL BE MADE THROUGH THE USE OF EXOTHERMIC WELD PROCESS. CONNECTIONS SHALL INCLUDE ALL CABLE TO CABLE SPLICES, TEES AND ALL GROUND ROD CONNECTIONS. MOLD, WELD KITS, ETC., SHALL BE MANUFACTURED BY CADWELD AND SHALL BE INSTALLED AS PER THE MANUFACTURER'S INSTRUCTIONS. 3. GROUND CONDUCTORS SHALL BE ROUTED IN THE SHORTEST AND STRAIGHTEST DISTANCES POSSIBLE TO MINIMIZE TRANSIENT VOLTAGE RISES. CONDUCTORS SHALL BE INSTALLED AS FOLLOWS' A. ALL GROUND CONDUCTORS SHALL FOLLOW A CONTINUOUS DOWNWARD PATTERN TO THE GROUND SOURCE. (NEVER RUN GROUND CONDUCTOR IN AN UPWARD DIRECTION.) B. CONDUCTORS SHALL BE INSTALLED WITH A MINIMUM OF 12 INCH MINIMUM BENDING RADIUS. C. WHEN THE MINIMUM BENDING RADIUS CANNOT BE ACHIEVED, GROUND CABLES SHALL BE ROUTED AT 90 DEGREE BENDS WITH THE USE OF EXOTHERMIC CONNECTIONS AT 90 DEGREES. THE INTENT IS TO ELIMINATE THE CABLE BEND RADIUS AND REPLACE THE RADIUS WITH AN EXOTHERMIC CONNECTION. PART III: EXECUTION 3.1 PREPARATION A. ALL SURFACES TO WHICH GROUND CONNECTIONS WILL BE MADE SHALL BE FREE OF PAINT, GALVANIZING DIRECT CORROSION ETC .. B. ALL METAL SURFACES EXPOSED ON GROUNDING SHALL BE EITHER COLD GALVANIZE, OR PAINTED TO MATCH ORIGINAL SURFACE. 3.2 EXAMINATION. A. EXAMINE AREAS AND CONDITIONS UNDER WHICH ELECTRICAL GROUNDING AND BONDING CONNECTIONS ARE TO BE MADE AND NOTIFY T -MOBILE CONSTRUCTION SUPERVISOR IN WRITING OF CONDITIONS DETRIMENTAL TO PROPER COMPLETION OF WORK. DO NOT PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE B. THE CONTRACTOR SHALL NOTIFY THE T -MOBILE CONSTRUCTION SUPERVISOR 24 HOURS PRIOR TO TRENCH BACK FILL ALL WORK DONE BELOW FINISHED GRADE SHALL BE INSPECTED BY THE AERIAL CONSTRUCTION SUPERVISOR DURING THAT PERIOD OR THE CONTRACTOR SHALL PROCEED. 3.3 GROUND TESTING A. THE CONTRACTOR SHALL TEST THE GROUND ELECTRODE ROD RESISTANCE IN ACCORDANCE WITH THE METHODS OF MEASUREMENT SHOWN IN THE FALL OF POTENTIAL METHOD. B. TEST INSTRUMENTS SHALL OPERATE AT A FREQUENCY OTHER THAN 60 HERTZ AND SHALL CONTAIN STRAY CURRENT AND DC FILTERS, FAULT CURRENT PROTECTION AND HAVE SENSITIVITY TO OPERATE A LOW SIGNAL STRENGTH. C. PRIOR TO TESTING, THE CONTRACTOR SHALL DE -ENERGIZE ALL POWER SOURCES, DISCONNECT THE ELECTRODE CONDUCTOR FROM THE GROUND ROD, WEAR HIGH VOLTAGE RUBBER SAFETY GLOVES AND WILL NOT HANDLE TEST INSTRUMENTS IF AT ALL POSSIBLE. D. GROUND TESTS ARE TO BE PERFORMED BY QUALIFIED PERSONS FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE EQUIPMENT AND THE HAZARDS INVOLVED. E. AN INDEPENDENT, APPROVED OUTSIDE FIRM SHALL PERFORM THE GROUND TEST AS OUTLINED. ALL TEST RESULTS SHALL BE FORWARDED TO THE T -MOBILE CONSTRUCTION SUPERVISOR FOR APPROVAL. END OF GROUNDING SPECIFICATIONS CLOSE OUT DOCUMENTATION CLOSEOUT BOOK CONTAINING THE FOLLOWING' 1. AS BUILT DESIGN DRAWINGS 2. SWEEP TEST RESULTS 3. RESISTIVELY TEST 4. PHOTO DOCUMENTATION OF' - UNDERGROUND CONDUITS AND GROUND RING - ANTENNA, COAXV\L, JUMPER ATTACHMENTS AND GROUND KIT ATTACHMENTS - ANTENNA DOWN TILT MEASUREMENT USING AN INCLINOMETER ON THE BACK PLANE OF THE ANTENNA - GROUND BAR ATTACHMENTS 5. SIGNED OFF PERMIT CARDS 6 CERTIFICATE OF OCCUPANCY 7. RETURN OF KEYS AND/OR ACCESS AUTHORIZATION B. ORIGINAL BUILDING PERMIT REVIEWED FOR ODE COMPLIANCE APPROVED la 1 2911 RECER' D CITY OF TUKWILA JUN 22 2017 city of Tukwila PERMIT CENTER BUILDING DIVISION] GENERAL NOTES SCALE. NTS 1 T • •M bil • o e A AMERICAN TOWER' POWDER RIVER Engineering Services, LLC w8w.powderriverdev corn LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE A. re -"3lONALft THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTRY ON OTHER PROJECTS WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: GENERAL NOTES SHEET NUMBER: GN -2 ONRAMP TO NORTHBOUND 1-5 X X EXISTING ACCESS ROAD X EXISTING FENCE --\ EXISTING VEGETATION EXISTING T -MOBILE PPC/TELCO CABINET ON CONCRETE PAD EXISTING T -MOBILE PURCELL CABINET EXISTING T -MOBILE ULTRASITE CABINET EXISTING T -MOBILE FCOA CABINET EXISTING T -MOBILE ICE BRIDGE O X X EXISTING VAULT DISCLAIMER: THESE DRAWINGS WERE PRODUCED WITHOUT THE BENEFIT OF A CURRENT LAND SURVEY, AND NO A&E SITE VISIT WAS PERFORMED. ALL PROPERTY LINES, EASEMENTS, SETBACKS, AND DIMENSIONS SHOWN SHALL BE VERIFIED PRIOR TO START OF CONSTRUCTION. POWDER RIVER DEVELOPMENT SERVICES, LLC. DOES NOT GUARANTEE THE ACCURACY OF SAID PROPERTY LINES, EASEMENTS, SETBACKS, AND DIMENSIONS SHOWN. EXISTING ICE BRIDGE (OTHERS) ♦ 11 ♦, • -Waft V V V V 0x11 x.00♦.O♦9.♦.1.♦9.♦9.19 • �1VA • 1 44 AA I IX �o♦.♦v ♦ A .ioi9.i�as•-� - AlIOi9.�� A•A111. Emir= --�--moi ,00001 - .I1999. i 9.00 A9.19.1� 0♦.1.001.1.♦.00O199.Ow9.0oo♦99�0A 4 VA A 9.♦.♦.1.♦.♦.1.0♦.O♦9.♦.1.♦.O♦9.1.19.1.1.♦999X�1�iI• THE UTILITIES AS SHOWN ON THIS SET OF DRAWINGS WERE DEVELOPED FROM THE INFORMATION AVAILABLE. THE INFORMATION PROVIDED IS NOT IMPLIED NOR INTENDED TO BE A COMPLETE INVENTORY OF THE UTILITIES IN THIS AREA. IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE LOCATION OF ALL UTILITIES (WHETHER SHOWN OR NOT) AND PROTECT SAID UTILITIES FROM ANY DAMAGE CAUSED BY CONTRACTOR'S ACTIVITIES. SITE PLAN REMOVE (2) FSME AND INSTALL (2) FSMF AND (1) FXFB 11, �P♦L99LY♦Y♦ ArP♦_♦Y♦99Y♦LAAt�= • , ♦• 1:1, •1.1 A Ems=lid I EXISTING MONOPOLE EXISTING UTILITY H -FRAME (OTHERS) EXISTING EQUIPMENT PLATFORM (OTHERS) X EXISTING VEGETATION X— REVIE CODE CO ,AP¢RO D FOR • LIANCE jell.. ► 7[11' City of I'ukwlla EXISTING CONCRETE WA LBU L DING DrOSION Know what's below. CaII before you dig. ORILLIA ROAD 4.. CITY OF T UKWiLA M 22 PERMIT CENTE SCALE. 1/4" = 1'-0" (24x36) (OR) 1/8" = 1'-0" (11x17) T • •Mobile • A AMERICAN TOWER® POWDER RIVER Engineering Services, LLC W/PN powderriverdev.00m LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE l • 4' i'* 14ci., 9571 4r4 , ,,, GI.SI Fi4� .�►(` 1 � �SION A4 Q'�G THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES. LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTOY ON OTHER PROJECTS WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: SITE PLAN SHEET NUMBER: C-1 EXISTING T -MOBILE APPURTENANCE LIST: EXISTING T -MOBILE APPURTENANCE LIST: NOTE: STRUCTURAL ANALYSIS MUST BE PERFORMED ON ALL ROOFTOPS, FLAGPOLES, LIGHT POLES, AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, RADIO UNITS, ETC. (1) ANTENNA PLATFORM (2) QUAD PORT ANTENNAS (2) HEX PORT ANTENNAS (4) TMA UNITS (4) DIPLEXERS (2) FRIG UNITS (2) FRLB UNITS (1) COVP UNIT h T.O. EXISTING ANTENNAS (OTHERS) �0 (1) ANTENNA PLATFORM (2) QUAD PORT ANTENNAS (2) HEX PORT ANTENNAS (2) FRIG UNITS (2) FRLB UNITS (4) TMA UNITS (8) DIPLEXERS (1) COVP UNIT (2) FHFB UNITS FOIE REVIEWED FOR COMPLIANCE APPROVED JUL, 17 2017 City of Tukwila SLPLDING DIVIS• IO0ONI h T.O. EXISTING ANTENNAS (OTHERS) YT.O.EXISTING EL. 61'-0" (AGL) DATE f� MONOPOLE G $ EL. 61'-0" (AGL) 0 C� T.O. EXISTING MONOPOLE 1 EL. 60.5' (AGL) 4 Ili EL. 60.5' (AGL) H 1r c_ EXISTING MICROWAVE (OTHERS) 8 ! g 1 EXISTING MICROWAVE (OTHERS) OF EXISTING EMPTY MOUNT (OTHERS) EL. 51'-0" (AGL) „ILc_ OF EXISTING EMPTY MOUNT (OTHERS) 100% CONSTRUCTION JMB A a" EL. 51'-O" (AGL) EL. 48' O" (AGL) EXISTING T -MOBILE TMA UNITS (2 PER SECTOR, 4 TOTAL) TO BE REMOVED h CL EXISTING T -MOBILE ANTENNAS -...� "I i 1.1(2 R EXISTING T -MOBILE FXFB UNITS 2 TOTAL) TO BE REMOVED EXISTING T -MOBILE FRIG UNITS (1PER SECTOR, 2 TOTAL) TO REMAIN EXISTING T -MOBILE ANTENNAS PER SECTOR, 4 TOTAL) TO REMAIN EL 48'-0" (AGL) PROPOSED T -MOBILE TMA UNITS (2 PER SECTOR, 4 TOTAL) 'G/S►fiL`' SIONAL Qv' THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE. ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE PROPSOED T -MOBILE FHFB UNITS (1 PER SECTOR, 2 TOTAL) EXISTING T -MOBILE FRIG UNITS PER SECTOR, 2 TOTAL) EXISTING T -MOBILE ANTENNAS SITE INFORMATION T -MOBILE #: SE03858A II I EXISTING T -MOBILE ANTENNAS (2 PER SECTOR, 4 TOTAL) P EL. 38'-0" (AGL) EXISTING T -MOBILE FRLB UNIT (1 PER SECTOR, 2 TOTAL) TO REMAIN EXISTING T -MOBILE DIPLEXER UNITS (2 PER SECTOR, 4 TOTAL) TO BE RELOCATED EXISTING T -MOBILE COVP UNIT (TO REMAIN) EXISTING MONOPOLE EXISTING T-MOBILEEXIST COVERED CONCRETE EQUIPMENT PAD N \ \\ SHEET TITLE: ELEVATIONS • QUIPMENT PLATFORM ING E(OTHERS) EL. 38'-0" (AGL) EXISTING T MOBILE FRLB UNIT (1 PER SECTOR, 2 TOTAL) TO REMAIN EXISTING T -MOBILE COVP UNIT EXISTING MONOPOLE EXISTING T -MOBILE COVERED CONCRETE EQUIPMENT PAD • g �� • PROPOSED T -MOBILE DIPLEXER UNITS (4 PER SECTOR, 8 TOTAL) RECEIVED CITY OF TUKWILA .3 N 222011 EXISTING PERMIT CENT • PLATFORMEQUIPMENT (OTHERS) - 1 �•�ig•••�•4lid •�•••••••1••N 1•••••••••••••••.•11i�••••••11••••1•�11.1••••••••1�••••II /N•�•NNn•NI .... /••• ••N n••N ;kw,. ....• ..� ... 1•l ••.•. 1•Na•••N .. I•Nn•••••••N1 .. �esnoXii•i 1•►INNN• 1.► .••••.•6 ••••1 . L....NI 1•�*V •••NN�•N•N►�• 1••••••••••••1 INNN,•••••••O•! .............. 1•.•••• ....NI i•������ ••••••• �•••••• ....... MOM pi•►• ••/ •�.♦•• 1$24:•• 4�0• • � ►1.�•.�.❖. 1•N�/�••• ►• • • .•• i1'•'1'•' • • M • •• ..•. • . • reels 1����•V•�11•••••••• N••••IN••••N 1•N••11•••••••11••••••••Sve,• NNN 1•••••N 1❖.•N•,...❖...•. . .. .. 1•••••1'••••!'=' •...• • u.....•• '••••••••••••'•i•Oii'A•R . ••••- •••••••• NI /••••••••••••❖••••••1 .❖.•••••.. NI •-•••••••%N• ..1 ••••• ••• :::� •• ••• •••«••• Awe.. ••N AWN •• • • •«❖...❖.. •. •r,«......... ••••••••••11 •••••••��i• «•••••••••I•. ••••N•N . . •❖! N••••Xi•••N ••••••••• J••••••••� h`••••••• •.•••••••�••••1 N•.fNN�•N• .....❖... ...... . .........�• .•. • ..� .. •��1 ... ... ... .• •..}}.. 'Nei. •••• NF: • •.•T••••4•••' •• •• . .•f•... •• .N••• . ...... ❖».►••❖•s❖•• � N��•�•. PPO' •N N• N/, .•• / ... ••W •1•• ii WC ••••••• N•••N•••N •••••• N•••N••.. ...... ❖•❖•❖N❖•❖•❖ �•� a ••N•• ••..% N•••• 1�1'•�/�•�1� •►••1• •1 x•1.1 �//••• ••. N•1• 1•N►r11•..�.. •,•►.•1•.!1•/•••.•.i❖.• ►.1... elt.„Vio • 9••y •y .. •• .. .. �•••Faii•� •••H.•••••N N•N ••••••.••••••• woe ...NN....... •••NNN N••NN••.--- .❖.❖.••.❖.•.!1.•. •••••••• N•••••• �... my", N••••••••N ••••••••••••�� N••••NNN ............•., •.••••NNN - N• ••❖•❖••i••❖•••, N•O• : _cave" •N ••;•••• • NNN ... . ..«•�•. •• •• •❖«•T•. . ••••••••••. •••••••••��i •••••••••I• ••••••••N• I....... 44.X..a... .••• ....•. ..... GRADE ;...... ;� •i.... •1•••111. P••N •••••••••••••••••/�•••••11••�a11•••••••1�•••••II 1••1 . •1••11••N1•C•• 'dii iiiiiii:••�• 1•••a.•. NI••►INN I•• ••• NI•1 : •• �I •• •"• l'.'.W:Wi ANWI! NN^ ••••.••11 N•N•Nh • •:::•:�' ,......,...... N•NN••••N 1••••••••• 1• •♦ •1 ••••• N•NN�••••N ••••••� �•••••• 1111 • •liii•••••ii ••••••••••••i. /•N1 •• •NN• •••••••••:••••A••• •N N• •• .•N• 1•• NNN•• •• .0.4_•!isj..!•!. • •• • •• 00 :VOWI.... N••••u•••!••• 1•••••/••••1••/1.1 • A••i I••N 1••.•1•••••NN •• 0.••••••••••41•,b •• • 1•N ••• I•• •••� ••'N•W'�LAb•1 1.1••••• •N• NN••N N• ••••••t••N• NN•••• ••• 1.1N••••1'••N• 4.4‘.••••••••••• & :•• • N•». .•M.•1 •NN• ••«NI •• NNNI ••.•• 7�s�� •�•••9••••••N N• �.�••••••••••♦ �•.N•••.••1N ••• , :••.0... N••.••••••••1 N.•••.••N1N dii iii ii•••iOVki, GRADE -....:�. �♦ 1111•••••�y,••• ••1•••••1 •NN11•P•.�• N••••••• NN•••�••••••a n.. �•• ••• •:: .N•j•s.., •N NN►••••N••. •N. •••./•••••�•••/ •N•N•1.1.1• •••.N1•NNN :.ii.&. N•••T•N N•N •N d. %4 •••••••••••••••••••••• •N••••1•••N •••••••N.N•N 11 ".•:•:•:•••••••••:••••:•.•••• N•••1N•NN •••••�•••i••��••••••••••••• •gl�.•/•.!1•r.❖.•.�..• •••NN •1 •1•► N�•N •NN1 ••►1 ..•!i!.!.!.! N, ••N•• ••.N ••♦ ••�•♦ NN•• i!Q•`.•i . •• i ............. ••••N.•N •••••••••�•••� •••••1.•N�1••• ••••••••1•••• •••••1.•N,1••• ••••N.•1N••• d :.:• 1••1 .•. 4.04 ••01,4 ...•Z•... N•••N•N•1 • •••NNN 1•+:14 • ♦1111•••♦ • 4*AV• • N1••N•••••• •••4••••••••••••• ••�. N• WO •NN •� ••NN ••.N • •1NN ••• • ••N•�•• 1, •ZA ' ••Ni••••••• •••4••••••• 1111••••••• ••••••••••♦ ,•1•.•1•••• •••••••••••••••••••••• EL. 0'-0" (AGL) EL. 0'-O' (AGL) TOWER ELEVATION (EXISTING) 6' 0 3' 6' SCALE: 3/16" = 1'-0" (24x36) 2 TOWER ELEVATION (PROPOSED)6'... _0 3' 6' SCALE 3/16" = 1'-0" (24x36) 1 (OR) 3/32" = 1'-0" (11x17) OR) 3/32" = 1'-0" (11x17) T • •Mobile • A AMERICAN TOWER' POWDER RIVER Engineering Services, LLC www.powderriverdev oom LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE •r ('fr • 't 'G/S►fiL`' SIONAL Qv' THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE. ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTRY ON OTHER PROJECTS WRHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: ELEVATIONS SHEET NUMBER: C-2 T • •Mobile • NOTE: AMERICAN TOWER@ STRUCTURAL ANALYSIS MUST BE PERFORMED ON ALL ROOFTOPS, FLAGPOLES, LIGHT POLES, AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, RADIO UNITS, ETC. POWDER RIVER Engineering Services, LLC ANTENNA SCHEDULESECT LICENSE #: 3004 REVISIONS REV ALPHA (RED) BETA (BLUE) 1 ,^1 ANTENNR NA POSITION A-1 A-2 B-1 8-2 1 REV+E VEE FOR ANTENNA TYPE G19/U21/L700 U19/L21/L19 G19/U21/L700 U19/1.21/L19 S9 CODE COMPLIANCE AZIMUTH 0' 0' 220' 220' RAD CENTER (AGL) 38'-0" 38'-0" 38'-0" 38'-0" APPROVED 0 MODEL COMMSCOPE SBNHH-1D65C COMMSCOPE TMBXX-6516-R2M COMMSCOPE SBNHH-1D65C COMMSCOPE TMBXX-6516-R2M 1 2017 CDE CABLE LENGTH ±70'-0" JUL 1 City of Tukwila BUILDING DIVISION 06wAs ANTENNA SCHEDULE (PROPOSED) ,9571 QA4 1 NTS N a _ - O_ N Q J EXISTING T -MOBILE ANTENNAS (2 PER SECTOR, 4 TOTAL) TO REMAIN EXISTING T -MOBILE FRIG UNITS a �o cn _ - II _ �� a w • • EXISTING T -MOBILE TMA UNITS . (2 PER SECTOR, 4 TOTAL) o TO BE REPLACED II EXISTING T -MOBILE FRLB UNITS a (1 PER SECTOR, 2 TOTAL) TO REMAIN EXISTING T -MOBILE DIPLEXER UNITS (2 PER SECTOR, 4 TOTAL) TO REMAIN a m. _ �o dN _J _J a m EXISTING T -MOBILE ANTENNAS w (2 PER SECTOR, 4 TOTAL) EXISTING T -MOBILE FRIG UNITS— (1 PER SECTOR, 2 TOTAL) II a i a a = N o rl�o EXISTING RELOCATED a rn r T -MOBILE DIPLEXERS - (2 PER SECTOR,LI 4 TOTAL) la t1 PROPOSED T -MOBILE TMA UNITS o (2 PER SECTOR, 4 TOTAL) II N EXISTING T -MOBILE FRLB UNITS a (1 PER SECTOR, 2 TOTAL) •F.-----, �iii�—amu ��:':'� r (1 PER SECTOR, 2 TOTAL) TO REMAIN m ii��"'1,4� ,-,:k , 1.8 ,„, , • 10� `-' , �r • i' � 0oJ QUO V$ ` iII 98188 SHEET TITLE: 'i `, � EXISTINGTO REMT-MOBILE COVP UNIT N PROPOSED T -MOBILE , DIPLEXER UNITS (2 PER ,� EXISTING T -MOBILE SECTOR, 4 TOTAL) �� PLATFORM `tit PROPOSED T -MOBILE ���� FHFB UNITS (1 PERNor EXISTING T -MOBILE COVP UNIT To REMAIN EXISTING T -MOBILE FX FB UNITS ` \ EXISTING T -MOBILE (2 TOTAL) TO BE REMOVED PLATFORM `\ . Nor • •` • e,� q, Pti N 44%4 v,w4Y II � SECTOR, 2 TOTAL) 0ti r R K�JE,�7, TTY C��- i.it�V ILA P JUN 2,,, N PERMIT CENTER *it. IL. ANTENNA PLAN (EXISTING) SCA 3 ANTENNA PLAN (PROPOSED) 2 NTSLE NTS T • •Mobile • A AMERICAN TOWER@ dktko POWDER RIVER Engineering Services, LLC www. powderriverdev.00m LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE P cil'I (it 06wAs ,9571 QA4 �yf, GISIPiY' "3.1014 AL °I' THESE PLANS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTRY ON OTHER PROJECTS WRHOUT PRIOR WRPTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: ANTENNA PLANS SHEET NUMBER: C-3 8'Rai 111 1 . 4i: 1 1 . 1 18 .,. 16 P ,g • 1 1 , ^ '. 1 I yS " RECEIVED D CITY OF TUKWILA. UN 22 20+1 PERMIT CENTER SEPARATE PERMIT AND, APPROVAL REQUIRED RFDS DIAGRAM SCALE. NTS 1 T • •Mobile• A AMERICAN TOWER® 4111044 POWDER RIVER Engineering Services, LLC www.powderriverdev.00m LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 1007 CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 907 CDE l• t'1 !j Oi•� c., G: qc• O� r, . • �S1OIN AL Q/4 THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES. LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTITY ON OTHER PROJECTS WRHOUT PRIOR WRRTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: RFDS DIAGRAM SHEET NUMBER: C-3.1 T . .Mobile» I4 ,55.5 937 ....g1w .... n ",.IL -11t _ 3,$4— .. a: - a?J 14.5.,► 1 1biU AP ' f O I a` 0.`,1 y4.5 p www.powderriverdev corn LICENSE #: 3004 REVISIONS a DATE U Op >• , Y .. mr Ell p 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE P t I-. wns c q� �� oy f'•. 7 967 k 1 ,N S!ONAL Q3 0 AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE t1 WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION }l® ATC #: 414339 18800 ORILLIA RD S. II 98188 B EQUIPMENT DETAILS SHEET NUMBER: C-4 iik( e.., MANUFACTURER: COMMSCOPE MODEL ETT19V2S12UB WEIGHT: 13.9 LB DIMENSIONS DIMENSIONS (HxWxD)' 9.4"x7.3"x3.5" FREQUENCY: 1850-1910 MHz (PCS) 1710-1755 MHz (AWS UL) 2110-2155 MHz (AWS DL) CONNECTION: 7/16 FEMALE <- . 0' "-r • < ,. MANUFACTURER: COMMSCOPE MODEL: ECC1920—VPUB WEIGHT: 7.9 LB DIMENSIONS (HxWxD): FREQUENCY RANGE: 1710-2155 MHz CONNECTION: 7/16 DIPLEXER 7.6"x7.3"x2.6" DIN FEMALE NOT USEDI SCALE 5 TMA DETAIL SCALE 3 DIPLEXER DETAIL SCALE NTS NTS NTS Flead Pole Kit (FPKA) description Fgrw eei Pei v.1f FPeAr � r :4�\ a `.. • Fixing pomis r- ,,r 1 iy 0�• T t� .AI rl -� Bolt M8x20 �. mow. j� _.. e '`"' i ... ' .• .., ,.,. —. • T• /` 1� 1j) I.. rit: r (H CITY jUN 22 2017 PERMIT CENTER AO C -1/111N11 CT UI". _> 4n, • ` i L t RX02 _, '• _ ���� Rps.gTE At I I .1 Rel ,.�,1‘ LAC 1_ aNT 2 1 rx aN' 1,3x i PAA ". , Foon9 pans Bolt M10X120 18.4 mni 17 2 in) r,.,.•' 105 mm thread F1e"IFrae r. It(FP0 A) -anbe used as f0110w^_ • 1517 31 1 3 1 p of e s Detw a an S tl m -n 1 4 111 r a n t s 20 m rn ; 4' b) 10 4 am a te' ,tri 212 poles heMe an 10 r01n1(1 2rnt and 1201110 (4, m ),n darShP' ,rhe h A Lut strainer Is O ppe1 arounl,vher the pole size Is f9 CCM or sn . II_r In 11ame1e I The writ ofthe fit ng ponts is 184 mm 17 2 In: and 54 oar (2 5 1x11 There are fix ny punts nr three =sriee V the FP0.A The M10 ;crews should be tightened oa 30 Nrn 123.13 ft_l3r and the MO Lore+rs to 20 Nur 314 75 h -lbt The rnarlrnum allowed we IOC or the FPk Aro 160 k (35 !Idol Two FPI. i Mit Lupport two FMFAs, one on each Id Sthe poe Each FMFAIplrnthican supportarTo"irnun oftwo 2Va 11FIe•1 mut Tee wall c 3;i20 ca Ie , aril tutu WET' bJae> (for es ample. CaLPH ^rote 1.11a15o1 Lrg_r co fiyora .ors 1h I. r._omr er,ied t0 u;e th. FPI C f, o e MIC Insttalhtbn with Remote FLr110 Heeds The FFk 4na;roon,' 7r •• F mote Palle Heads(=Rir >-FHE,FRi-1L..HP OOC!Uied) It to po le tr u e three Ir;tali goo 0 d1 a nom- E Figure FFI:AwIth three Pmote F.JYro Head- Mr me FF'c. 11 stallitle�r with rhrue Re,o,r1. Rale, Head; 1T7 r L . E`'2 AP 4i ��ry�I ) j'���KOVAL v + FACTURER: NOKIA .R / // /�1 L: RRH 4x40W J]Rr ' NSIONS: H = 23.0" (NO BRACKETS) NOTE: CO W = 12.6" (NO SOLAR SHIELD) SOLAR SHIELD NOT SHOWN = 7.8" FREQUENCY: 1850MHz-1995MHz FHFB WEIGHT: 51.0 LBS NOT USED SCALE 6 FPKA DETAIL SCALE 4 FHFB DETAIL SCALE ^ L NTS NTS NTS T . .Mobile» A AMERICAN TOWER' POWDER RIVER Engineering Services, LLC www.powderriverdev corn LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE P wns c q� �� oy f'•. 7 967 k 1 ,N S!ONAL Q3 THESE PLANS AND SPECIFICATIONS. AS INSTRUMENTS OF SERVICE ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTRY ON OTHER PROJECTS WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: EQUIPMENT DETAILS SHEET NUMBER: C-4 T • •Mobile • A AMERICAN TOWER® \% irtill‘ 10PVr I I / Engineering Services, LLC COPPER BONDING CONDUCTORS TO CABLES AND EQUIPMENT. SEE GROUNDING PLANS FOR DETAILS 3/8" BOLT AND HARDWARE (TYP.) LICENSE #: 3004 REVISIONS 0000 DATE DESCRIPTION INT Co 00 ®®®®p� Q', i ♦�1 �i�'`ta9, CHERRY BUSS BAR ® V r INSULATOR (TYP OF 2). i NOT USED WHEN DIRECT ®®0 ,a O `/ .1 I ' 0 J �� ATTACHMENT TO TOWER i•i ®0 0 '-ft ®®i®i0 0 ®® 0 1 , STEEL IS REQUIRED JMB if 04/13/17 ISSUED FOR REVIEW 90% CDE . *• (,� r ) o�c� IA, 'P cor,> 0 49671 • J ¢4 4,,,,. 4"x24"x1/4" TINNED COPPER GROUND BAR (HAGER OR 410NAL e14 i, THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTRY ON OTHER PROJECTS APPROVED EQUIVALENT) '� T -MOBILE #: SE03858A WALL—MOUNT BRACKET 18800 ORILLIA RD S. #2 AWG SOLID TINNED COPPER OR ANGLE ADAPTER 98188 CONDUCTOR TO MAIN GROUND (AS REQUIRED) GROUNDING BAR OR EXISTING GROUND RING SHEET NUMBER: (TYP.). CADWELD TO BUSS BAR AND GROUND RING NOT USED SCALE 3 GROUND BAR DETAIL SCALE NTS NTS NOTES: 1. CADWELD "TYPES" SHOWN ARE EXAMPLES. CONSULT WITH CONSTRUCTION MANAGER FOR SPECIFIC TYPES OF CADWELDS TO BE USED FOR THIS PROJECT. 2. CADWELDING IS NOT ALLOWED ON CROWN CASTLE TOWERS. Pilildp....„ 111.1 \14. i N TYPE 2 YA 2 TYPE VS TYPE YGHC Irli � y -. CITY OF TUKW1L ,;tit' 22 2011 �♦iiir,---,, iiiiillsisc„ _ PERMIT CENTER tO TYPE GT TYPE YA-2 TYPE PT PC PARAT� ApiiTAND RE'Q� HVAC D NOT USED SCALE CADWELD CONNECTION SCALE NTS 4 TYPES NTS T • •Mobile • A AMERICAN TOWER® Ali?, POWDER RIVER Engineering Services, LLC www.powderriverdev oom LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 100% CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE . *• (,� r ) o�c� IA, 'P cor,> 49671 • J ¢4 G1.Si 01:4C- ��� 410NAL e14 THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTRY ON OTHER PROJECTS WRHOUT PRIOR WRTTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: GROUNDING DETAILS SHEET NUMBER: E-1 T • •Mobile • EXISTING #6 AWG GROUND FROM SECTOR GROUND BAR TO COLLECTOR GROUND BAR (TYP) PROPOSED #6 AWG GROUND FROM FHFB UNIT TO SECTOR EXISTING SECTOR GROUND BAR (TYP) GROUND BAR AMERICAN TOWER® EXISTING RELOCATED PROPOSED T -MOBILE TMA UNITS POWDER RIVER T -MOBILE DIPLEXERS www.powderriverdev oom (2 PER SECTOR, (2 PER SECTOR, 4 TOTAL) REVISIONS 4 TOTAL) EXISTING T—MOBILE FRLB UNITS DATE EXISTING T—MOBILE ANTENNAS (1 PER SECTOR, 2 TOTAL) INT (2 PER SECTOR, 4 TOTAL) EXISTING T—MOBILE FRIG UNITS Mk ill (1 PER SECTOR, 2 TOTAL) r':1 MI 1-----1a.i•i =44• �:, �r ♦♦ % ��' PROPOSED T-MOBILE,484, DIPLEXER UNITS (2 PER / i I OCOLLECTOR L) ``�r0�-/ EXISTING ♦/ GROUND BAR :•i 1 UNIT `� EXISTINGT—MOBILE COVP TO N 1\i.".. EXISTING T—MOBILE �� PLATFORM 0 PROPOSED T -MOBILE \\ �• 1007 CONSTRUCTION FHFB UNITS (1 PER % A ♦` SECTOR, 2 TOTAL) ISSUED FOR REVIEW 90% GENERAL GROUNDING NOTES: s 1. GROUNDING SHALL COMPLY WITH NEC, T—MOBILE AND NSN STANDARDS. CONTRACTOR SHALL VERIFY EXISTING GROUNDING O CONDITIONS. CORRECTING ANY DEFICIENCIES TO BE INCLUDED IN ORIGINAL PRICING AND CORRECT DEFICIENCIES DURING wAS 1/4'" te NEW CONSTRUCTION. INCLUDING MISSING GROUND BARS, BAD GROUND WELDS, MISSING GROUND LEADS OR BROKEN GROUND LEADS, ETC. G`���o- �' "SIGNAL Q - 2. ALL EXTERIOR GROUND CONDUCTORS BETWEEN EQUIPMENT/ GROUND BARS AND THE GROUND RING, SHALL BE #2 AWG AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE SOLID TIN PLATED COPPER IN 3/4" PROTECTIVE PVC UNLESS OTHERWISE INDICATED. WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. 3. APPROVED ANTIOXIDANT COATINGS (NO—OX) SHALL BE USED ON ALL COMPRESSION AND BOLTED GROUND CONNECTIONS. T -MOBILE #: SE03858A 4. ROUTE GROUNDING CONDUCTORS ALONG THE SHORTEST AND STRAIGHTEST PATH POSSIBLE. USE OF 90' BENDS IN THE 18800 ORILLIA RD S. PROTECTION GROUNDING CONDUCTORS SHALL BE AVOIDED WHEN 45° BENDS CAN BE ADEQUATELY SUPPORTED. IN ALL 98188 CASES, BENDS SHALL BE MADE WITH A MINIMUM BEND RADIUS OF 12 INCHES. GROUNDING 5. ALL TOWER TOP GROUND WIRES SHALL BE SUPPORTED EVERY TWO FEET. BE S SHEET NUMBER: j RECFjt1 0 , CITY OF TLJ�CWiL . LEGEND: ---- EXISTING GROUND RING 2 2 Lid I • N J, CADWELD CONNECTION (EXOTHERMIC WELD) �A CENTER • MECHANICAL CONNECTION SEPARATJ3ERMIT .�' ', ® GROUND ROD RE��'�D •Al* ��� TEST WELLHALrseL RED NOT USED SCALE 2 EQUIPMENT PLAN SCALE NTSI GROUNDING (TYPICAL) NTS T • •Mobile • A AMERICAN TOWER® ,4041, POWDER RIVER Engineering Services, LLC www.powderriverdev oom LICENSE #: 3004 REVISIONS REV DATE DESCRIPTION INT 0 05/01/17 1007 CONSTRUCTION JMB A 04/13/17 ISSUED FOR REVIEW 90% CDE s •t O � wAS 1/4'" te \ FG1� Fit G`���o- �' "SIGNAL Q - THESE PLANS AND SPECIFICATIONS, AS INSTRUMENTS OF SERVICE, ARE AND SHALL REMAIN THE PROPERTY OF POWDER RIVER DEVELOPMENT SERVICES, LLC WHETHER THE PROJECTS FOR WHICH THEY ARE MADE ARE EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATIONS SHALL NOT BE USED BY ANY PERSON OR ENTITY ON OTHER PROJECTS WITHOUT PRIOR WRITTEN CONSENT OF THE ENGINEER. SITE INFORMATION T -MOBILE #: SE03858A ATC #: 414339 18800 ORILLIA RD S. TUKWILA, WA 98188 SHEET TITLE: GROUNDING PLANS SHEET NUMBER: E-2 11/2/2017 City of Tukwila Department of Community Development ERIC SHAW 219 S WOODDALE AVE EAGLE, ID 83616 RE: Permit Application No. D17-0170 T -MOBILE 18800 ORILLIA RD S Dear ERIC SHAW, Allan Ekberg, Mayor Jack Pace, Director In reviewing our current application files, it appears that your permit applied for on 6/22/2017, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Currently your application has a status of APPROVED and is due to expire on 12/22/2017. If you still plan to pursue your project, you are hereby advised to do one of the following: 1) If the plan review is complete for the project and your application is approved, you may pick up the application before the date of expiration. At the time of permit issuance the expiration date will automatically be extended 180 days. -or- 2) If the plan review is not completed submit a written request for application extension (7) seven days in advance of the expiration date. Address your extension request to the Building Official and state your reason(s) for the need to extend your application. The Building Code does allow the Building Official to approve one extension of up to 90 days. If it is determined that your extension request is granted, you will be notified by mail. In the event that we do not receive your written request for extension or request is denied, your permit application will expire and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: D17-0170 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: D17-0170 PROJECT NAME: T -MOBILE SITE ADDRESS: 18800 ORILLIA RD S X Original Plan Submittal Response to Correction Letter # DATE: 06/22/17 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: ittiO C (D 7 Building Division Ili \ J 7 NR- 4 Public Works W I'�AtL�l� Fire Prevention Structural J) P Planning Division Permit Coordinator 1111 PRELIMINARY REVIEW: Not Applicable n (no approval/review required) REVIEWER'S INITIALS: DATE: 06/27/17 Structural Review Required DATE: n APPROVALS OR CORRECTIONS: DUE DATE: 07/25/17 Approved Corrections Required n Approved with Conditions n Denied (corrections entered in Reviews) (ie: Zoning Issues) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire D Ping ❑ PW ❑ Staff initials: 12/18/2013 SAC WIRELESS LLC Washington State Department of Labor & Industries lInme i guano? ( _I :CI SafotV & Health Claims & insurence Page 1 of 2 Search L -&I A leder thip Workplace Rights Trades & Licensing SAC WIRELESS LLC esperson SANZO, JOSEPH (JOSE) PASQUALE, MANAGER KOZIEL, BILL R, MANAGER SAC WIRELESS LLC 603 391 663 540 MADISON STREET 16TH FLOOR CHICAGO, IL 60661 847-944-1600 Busillet;s type Limited Liability Company 1-11 Deett(me LLC NOKIA SOLUTIONS & NE HALL CAPITAL PARTNERS; BILL KOZIEL, JOE SANZO; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor l :a ',trio: l GENERAL t_iue rlSe 110 SACWIWL852J2 t ffc tine ..- e t W tion 07/01/2015— 07/01/2019 Bond Washington International Ins Co tion,.: atecotint nz.;. 9170096 04/21/2015 Insurance XL INSURANCE AMERICA INC no us000754031i17a Rcac ✓ u y LeA 05/04/2017 Insurance history Active. Meets current requirements. $12,000.00 t ffe:ctivE.:12th 04/17/2015 Espiratin,7 chafe Until Canceled $5,000,000.00 r fter;tve date 05/01/2017 Ye.CG5 ate 05/01/2018 Help us improve https://secure. lni.wa.gov/verify/Detail.aspx?UBI=603391663&LIC=SACWIWL852J2&SAW= 12/7/2017 SAC WIRELESS LLC Savings No savings accounts during the previous 6 y.ar period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. This company has multiple workers' comp accounts. Active accounts L&I Account ID 127,365-01 Doing business as SAC WIRELESS LLC Estimated workers reported Quarter 3 of Year 2017 "31 to 50 Workers" L&I account contact T4 / NIKKI BUTLER (360)902-4918 - Email: BUTQ235@Ini.wa.gov Track this contractor 0 Account is current. Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health No inspections during the previous 6 year period. Page 2 of 2 Washington State Dept or Lohor & Industries. Use of this site is subject to the hers of the state of Washington. Help us irnprove https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603391663&LIC=SACWI WL852J2&SAW= 12/7/2017