Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M17-0060 - APPLEBEES - HVACT ROOFTOP UNITS
APPLEBEES 17790 SOUTHCENTER PKWY EXPIRED 06/12/18 M17-0060 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.sov MECHANICAL PERMIT 3523049005 Permit Number: M17-0060 17790 SOUTHCENTER PKWY Project Name: APPLEBEES Issue Date: 5/22/2017 Permit Expires On: 11/18/2017 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: KIR TUKWILA 050 LLC/KIMCO 3333 NEW HYDE PARK STE 100 PROPERTY TAX DEPARTMENT, NEW HYDE PARK, WA, 11042 JOHN HOWARD 11227 217 ST CT E , SPANAWAY, WA, 98338 PACIFIC REFRIGERATION UNLMTD 11227 217TH ST CT E , GRAHAM, WA, 98338-6455 PACIFRU831JO Phone: Phone: (253) 292-8728 Expiration Date: DESCRIPTION OF WORK: REMOVE EXISTING HVAC ROOFTOP UNITS, REPLACE WITH NEW Valuation of Work: $5,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $711.25 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: HIGHLINE,TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: lf/A;, Date:5izz��� 1 hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree the conditions attached to this permit. Signature: /, i Print Name: /� /4652>i . 7' 50le r1 Date:572-7//7 ` 2/' / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 2: ***MECHANICAL PERMIT CONDITIONS*** 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 7: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 8: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 9: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 10: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2437)' 11: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 12: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 13: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 14: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 15: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 16: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUK11 4 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.flOV Mechanical Permit No. M 11' 0460 Project. No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: /7 7c7 5 O (-7-4 4- (-, 9y' Suite Number: Tenant Name: ft�'f/,c S G / PROPERTY OWNER Name: 7L --)I /9- Address: "--- //i3,� 7 A/7 sr z'T Name: •,,j ' s Email: 7A viS U/-E"� x.41.4-// , Z'e:) . _ Address: /) 7 96 _ Sa 4-77 w +y City: Contr Reg No.: /61- State: Zip: CONTACT PERSON — person receiving all project communication Name: 7L --)I /9- Address: "--- //i3,� 7 A/7 sr z'T City:...,State: Zip: 6,04 "8.33c9 ,.9w/-Ic..74 Phone: / Fax: 076-3-072..7 47aE3 rur9 Email: 7A viS U/-E"� x.41.4-// , Z'e:) . New Tenant: Floor: ❑ Yes Va..No MECHANICAL CONTRACTOR INFORMATION Company Name: 6a.7/✓e/moi/ P/ -e/ -i7- /c—'- i-��h Address 7 aJ 7 sem'- e-7. _ City: SifAState: ,z;/1�,./iy A Zip: 7833 Phone 3� ,- 97 Sm)2 Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ , 5000 Describe the scope of work in detail: 00 Use: Residential: New ❑ Commercial: New Fuel Type: Electric ❑ Gas Replacement Replacement ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 *Daytim District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-10pm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 4 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNELfl/ T ORIZED AGENT: Signature: (Q Date: _,-oi /7 Print Name: Mailing Address: // Day Telephone: <9 ! 6338 State Zip City H:\Applications\Forms-Applications on Line\2016 Applications\Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK, ACCOUNT QUANTITY PAID $439.21 M17-0060. Address: 17790 SOUTHCENTER PKWY Apn: 3523049005 $439.21 Credit Card Fee $12.79 Credit Card Fee I R000.369.908.00.00 I 0.00 $12.79 MECHANICAL $410.02 PERMIT FEE R000.322.100.00.00 0.00 $328.01 PLAN CHECK FEE R000.322.102.00.00 0.00 $82.01 TECHNOLOGY FEE $16.40 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11540 R000.322.900.04.00 0.00 $16.40 $439.21 Date Paid: Monday, May 22, 2017 Paid By: ALEKSEY SOKIRKIN Pay Method: CREDIT CARD 712272 Printed: Monday, May 22, 2017 3:27 PM 1 of 1 erti SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ( ACCOUNT I QUANTITY PAID $272.04 M17-0060 Address: 17790 SOUTHCENTER PKWY Apn: 3523049005 $272.04. Credit Card Fee $7.92 Credit Card Fee I 8000.369.908.00.00 I 0.00 $7.92 MECHANICAL $253.96 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $170.02 PLAN CHECK FEE R000.322.102.00.00 0.00 $50.79 TECHNOLOGY FEE $10.16 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R11406 R000.322.900.04.00 0.00 $10.16 $272.04 Date Paid: Tuesday, May 02, 2017 Paid By: VIOLA S CHIOSAC Pay Method: CREDIT CARD 712031 Printed: Tuesday, May 02, 2017 3:14 PM 1 of 1 CRSYSTEMS INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Proje t: t Typeof Inspection: / L «7%f4Paa 11/6-61-/ris' CA - Address: j7790 Se-4tm1car IT -14 Date Called: Special Instructions: //13V- /2 !OD C eCT Date Wanted: lr / 7 a.m. p.m. Requester: Phone No: 7n-3441 //67 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd,. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 07-0660 Proje t: zi= z l5 Type of Inspection: fi12/I+,tdCm,i.4i... Address: /7790 -. 4e Pili Date Called: Instructions: Date Wanted: akii 7Special a. . Requester: Phone No: 0 Approved per applicable codes. Eia Corrections required prior to approval. COMMENTS: Accecs )&w 126- See/ 1.-?•-vz-e-' idtisPeeac-A/ Inspector: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 206-575-4407 Project:,Type ii pO�e,s HI/ of Inspection: Fire Alarm: b4 Addressl. / Suite #: l � -�G pe4AA41 Contact Person: / (�'j a 'l Permits: Special Instructions: I Phone No.: ` 25-3-2`3—1 44 - Approved per applicable codes. • Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Pallo i n OE-- Ffr i - - pt --(2444, (.7- 4-/Qb cr-EV---- t'11- - © fa- 7b /.N . iGr2 k- 7e)R y c Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: FTVISA.—. Date: (Opg3h�-- Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 3/14/14 T.F.D. Form F.P. 113 SITTS. & HILL ENGINEERS, INC. Professional Engineers and Planners 4815 Center Street,. Tacoma, WA 98409 www.sitts-hill-engineers.com (253) 474-9449 April, 26, 2017. TRUE REFRIGERATION UNLIMITED 11227 217TH Street Court East Graham, Washington 98338 TO: Alex Sorkirkin BRENT K. LESLIE, P.E. KATHY A. HARGRAVE, P.E. LARRY G. LINDELL, P.E. MICHAEL A. McEVILLY, P.L.S. SUBJECT: ANALYSIS OF EXISTING ROOF FOR REPLACEMENT HVAC UNITS — APPLEBEE'S RESTAURANT, LOCATED AT 17790 SOUTHCENTER PARKWAY, TUKWILA, WASHINGTON SITTS AND HILL PROJECT NUMBER 17321 Dear Alex, We understand that you are proposing to replace five existing rooftop mounted air handling units at 17790 Southcenter Parkway in Tukwila, Washington. The existing roof structure consists of wood joists bearing on wood beams. These support a plywood deck, insulation and a roof membrane. The joists are spaced at approximately 2 ft. on center and span approximately 18'-0" between supports. 4x12 beams support each side of the rooftop units. Our analysis is based on the equipment information you provided and field measurements. Units RTU -1, RTU -2 and RTU -3: • Existing units are York DAUS-T090 7.5 Ton units weighing approximately 1,310 lbs. each. • Proposed units are York ZFO90 7.5 Ton units weighing 1,230 lbs. each, including curb adapter. • Units will be mounted in the same location as existing equipment. A curb adapter will also be installed. Since the proposed units weigh Tess than the existing units, the roof structure is ade for these three units. Unit RTU -4: • Existing unit is a York DGUC-060 5 ton unit weighing approximately 888 Ib • Proposed unit is a York ZE-0060 5 ton unit weighing approximately 694 lbs. • Unit will be mounted in the same location as the existing unit. Since the proposed unit weighs Tess than the existing unit, the roof structure is ade M(7 oo&c Civil, Structural and Survey uate b '. _I..• REVIEWED FOR CODE COMPLIANCE APPROVED MAY 1.8 2017 ,QjfitolTukwila 1111.31tOWNVisioN RECEIVED CITY OF TUKWILA MAY 02 2017 PERMIT CENTER TRUE REFRIGERATION UNLIMITED April, 26, 2017 Page 2 of 2 Unit RTU -5; • Existing unit is a York DGUC-076 6 ton unit weighing approximately 1,050 lbs. • Proposed unit is a York ZF-078 6.5 ton unit weighing approximately 1,310 lbs., including the curb adapter. • The proposed unit will be mounted on a curb that distributes the unit load over (2) 4x12 roof beams. The unit will be located approximately 7 ft. from the East edge of the roof. • A roof snow load of 25 PSF was used in our analysis. Based on our review of the roof, the existing 4x12 beams are structurally acceptable to support the proposed replacement unit. Thank you for the opportunity to provide structural engineering services. Please feel free to contact our office with any additional questions or comment regarding this project. Sincerely, Sifts and Hill Engineers, Inc. Ed Brown, P.E. Senior Project Engineer 117321/corres/2017-04-26 True Refrigeration WIYORK SUBMITTAL DATA Order #: Project: Project #: Location: Purchaser: For: Quotation Date: 02/09/2017 APPLEBEES-TUKWILLA NN02091701 APPLEBEES-DON D. Mt'7'Q0 (pb REVIEWED FOR CODE COMPLIANCE APPROVED MAY 182017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 02 2011 PERMIT CENTER Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local. codes. Printed 02/09/2017 Date 02/09/2017 Project Name APPLEBEES-TUKWILLA Project Number NN02091701 Client /:Purchaser APPLEBEES-DON D. Qty Tag # Model # Submittal Summary Page Description 3 RTU -1, 2 & ZFO9ON18R2B1EAA1A1 3 -FACTORY BLD -5 WKS 7.5 Ton, Two Stage Cooling, :Single Packaged R-410AAir Conditioner, Standard Efficiency, 11 EER / 12.2 LEER (CV) / 13.5 IEER •(Intellispeed) / 12.2 IEER (VAV), 180 MBH Input Aluminized Steel, Two Stage Gas Heat, 208/230-3-60 • Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Return Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) • 3 HP High Static Belt Drive Blower • Standard 2" Throwaway Filters. • Simplicity® SE Controller including Discharge Air, Retum Air, and Outdoor Air Temperature Sensors •,IntelliSpeed control of the VFD based on stages of cooling (Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) • Retum Air Smoke Detector (Bottom return only) • Micro -Channel "all -aluminum" condenser coil, Copper tube/aluminum fin evaporator coil • Standard Cabinet with Composite Drain Pan Curb Adapter Old Model: DAUS-T090-7.5 TON New'Model: ZFO90=7.5 TON Top Brace; Insulated Condenser Panell:(where required); FullyInsulated (1" R Value Unitary Sales Tool v1.5.9.0 .. Information is subject.to change without notice. Check local codes. Printed 02/09/2017 Qty Tag # Model # Description 1 RTU-4-D/R- ZE060H 1 2A2C1 EAA1 A1 5 Ton, Single Stage Cooling, York Small Sunline Single Packaged R - FACTORY 410A Air Conditioner, 11.8 EER / 14.0 SEER, 125 MBH Input, Single BLD -5 WKS Stage Gas Aluminum Steel, 208/230-3-60 • Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) • 1 HP Direct Drive Blower • 1" Throwaway Filters • Simplicity® SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors • Return Air Smoke Detector • Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil • Galvanized Steel Drain Pan • Standard Access Doors y,^!a„�, 1 rr°'i. "u^:.24T" -a .•--.. .7 . ,� .v..--e.y .."q•^t, -v. r.�-♦.,s.r -�°. 'RS".za"'i I t . . 1 f ::k - .1 RDO410Barometric Relief Damper with Hood`Kit (Downflow'Unit or Duct ' - c Mounted) RTU -5- ZFO78N12R2B1EAA1A1 FACTORYB LD -5 WKS 6.5 Ton, Two Stage Cooling, Single Packaged R -410A Air Conditioner, Standard Efficiency, 11.2 EER / 12.3 IEER (CV) / 13.8 IEER (Intellispeed) / 12.3 IEER (VAV), 120 MBH Input Aluminized Steel, Two Stage Gas Heat, 208/230-3-60 • Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Retum Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, Califomia Title 24, AMCA 511) • 2 HP High Static Belt Drive Blower • Standard 2" Throwaway Filters • Simplicity® SE Controller including Discharge Air, Retum Air, and Outdoor Air Temperature Sensors • IntelliSpeed control of the VFD based on stages of cooling (Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) • Retum Air Smoke Detector (Bottom return only) • Micro -Channel "all -aluminum" condenser coil, Copper tube/aluminum fin evaporator coil • Standard Cabinet with Composite Drain Pan 5 DAYS : ;CDI 1=500550355'. , "Curb Adapter OId Model DUC076-6 TON . New Model ZF,078-6:5 TON :: Top Brace, Insulated Condenser Panel (where -required);'Fully Insulated thicT Liner R -Value 3:85)" Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information & guidance. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 4 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZFO9ON18R2B1EAA1A1 Quantity: 3 Tag #: RTU -1, 2 & 3- FACTORY BLD -5 WKS System: ZFO9ON18R2B1EAA1A1 (3) Cooing rerrormance Total gross capacity 93.0 MBH Sensible gross capacity 66.8 MBH Total net capacity 86.3 MBH Sensible net capacity 60.1 MBH Efficiency (at ARI) 11.00 EER Integrated eff. (at ARI) 13.50 IEER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.4 °F Leaving WB temp. 57.2 °F Power input (w/o blower) 7.30 kW Sound power. 89 dB(A) Refrigerant Refrigerant type R -410A Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 144 MBH Supply air 3000 CFM Heating input capacity (Max) 180 MBH Leaving DB temp. 104.4 °F Air temp. rise 44.4 °F SSE 80.0 % Stages 2 Supply Air Blower Performance Supply air 3000 CFM Ext. static pressure 0.7 IWG Addl. Unit Losses (Options/Accessories) 0.2 IWG Blower speed 1282 RPM Max BHP of Motor (including service factor) 3.45 HP Duct location Bottom Motor rating 3.00 HP Actual required BHP 2.10 HP Power input 1.96 kW Elevation 0 ft. Drive type BELT Electrical Data Power supply 230-3-60 Unit min circuit ampacity 42.4 Amps Unit max over -current protection 50 Amps Dimensions & Weight Hgt 42 in. Len 89 in. Wth 59 in. Weight with factory installed options 1075 lbs. Clearances Right 12 in. Front 36 in. Back 36 in. 79 in ilnf+nm fl in 1 nft QF in • Note: Please refer to the tech guide for listed maximum static pressures i r �+i CERTIFIED -•.111.0C1Itr EEC AMERICAN QUALITY Cch, cr)t 7.5 Ton • York Predator units are manufactured at an ISO 9001 registered facility and each rooftop is completely computer -run tested prior to shipment. Unit Features • Standard Cabinet with Composite Drain Pan • Two Stage Cooling • 180 MBH Input Aluminized Steel, Two Stage Gas. Heat • Full perimeter base rails with built in rigging capabilities • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Reciprocating Compressor • Dry Bulb Low Leak Economizer wBarometric Relief and Hoods (Bottom or Horizontal End Return Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, Cal fomia Title 24, AMCA 511) • 3 HP High Static Belt Drive Blower • Unit Ships with 2" Throwaway Filters • Solid Core Liquid Line Filter Driers • Replacement Filters: 4 - (24" x 16"). Unit accepts 2" or 4" wide filters. • Short Circuit Current: 5kA RMS Symmetrical • Through -the -Curb and Through -the -Base Utility Connections • Single Point Power Connection • Retum Air Smoke Detector • Micro -Channel "all -aluminum" condenser coil, Copper tube/aluminum fin evaporator coil • Hinged Access Panels BAS Controller • IntelliSpeed control of the VFD based on stages of cooling. Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10. • Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Standard Unit Controller: Simplicity Control Board • Safety Monitoring - Monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, safety lockouts and re Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • Ten (10) Year Limited Warranty - Aluminized Steel Heat Exchanger Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 N524 Page: 5 r2Y0 a Predator (3-12.5 Ton Package) York Single Package R -410A Air Conditioner Project Name: APPLEBEES-TUKW1LLA Unit Model #: ZFO9ON18R2B1EAA1A1 Quantity: 3 .Tag #: RTU -1, 2 & 3- System: ZFO9ON18R2BIEAAIA1 (3) FACTORY BLD -5 WKS Factory Installed Options i ZFO9ON18R2B1 EAA1A1 Product Category: ZF Single Packaged. R -410A Air Conditioner, Standard Efficiency • 11 EER / 12.2 IEER (CV) / 13.5 IEER (Intellispeed) / 12.2 IEER (VAV) Nominal Cooling Capacity: 090 7.5 Ton Two Stage Cooling Heat Type and Nominal Heat Capacity: NI8 180 MBH Input Aluminized Steel, Two Stage Gas Heat Airflow: R 3 HP High Static Belt Drive Blower IntelliSpeed control of the VFD based on stages of cooling (Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) Voltage: 2 208/230-3-60 Economizer / Damper: B Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Return Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, Califomia Title 24, AMCA511) Sensor Options: E Retum Air Smoke Detector (Bottom return only) Controls: A Simplicity® SE Controller including Discharge Air, Retum Air, and Outdoor Air Temperature Sensors Refrigeration: A Micro -Channel "all -aluminum" condenser coil, Copper . . tube/aluminum fin evaporator coil Additional Options: 1 Standard 2" Throwaway Filters Cabinet Options: A Standard Cabinet with Composite Drain Pan Field Installed Accessories • Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 to Predator (3-12.5 Ton Package) N524 Page:6 York Single Package R -410A Air Conditioner Project Name: APPLEBEES-TUKWILLA Unit Model #: .ZFO9ON18R2BIEAAIA7 Quantity 3 Tag # RTU -1, 2 & 3 -FACTORY BLD -5 System: ZFO9ON18R2BIEAAIA1 (3) WKS Consolidated Drawing NOTES: 1. FOR OUTDOOR USE ONLY. TONNAGE 1 II OPERATING WEIGHT LBS) WEIGHT(LBS) CENTER OF GRAVITY LOCATION (BASE UNIT) -- 4 POINT CORNER LOADS LB ( S) (BASE UNIT) 2. WEIGHTS SHOWN ARE FOR COOLING CNLY UNITS. T 'BASE K Y A - - B C O 3. MIN. CLEARANCES TO BE: 6.5 ZF 860 398 38 [965] 24 619 200 91 149 68 218 (99 292 1331 RIGHT SIDE: 12 305] 7.5 2F 880'399 38 [965] 24 610 205 "93': 153 '69 223 [101 299 '136] LEFT SIDE: 36 915] 5 rd 864 393 40 [1016] 26 -660' 210 '95' 171 78 217 [99' 266 -121] FRONT: 36 915]] 6.5 & 7.5 24 910 -413 38 [965] 24 "610 212 '96 158 -72` 238 [104' 309 '1401 REAR: 36 915 5 23 770 349 40 [1016] 24 610 172 78 141 '64' 205 [93 251 "114] TOP: 72 1630] BOTTOM: 0 8 - 32.68 4 ZR 880 '399 40 [1016] 26 660 214 '97 174 '79" 221 [100 271 723] 4. TO REMOVE THE SLIDE -OUT DRAIN PAIN, A REAR CLEARANCE OF g [ 30] 5 ZR 868 394 40 [1016] 26 '660 211 -96" 172 '78" 218 [99 267 '1211 60 in (1525 Rte) IS REQUIRED. IF SPACE IS UNAVAILABLE, THE 6.83 _ 584' 214 _ 97' 161 -73 _ 249 [1 333 _ DRAIN PAN CAN 6E REMOVED THROUGH THE FRONT BY SEPARATING [173]..[ 7.5 ZR 965 438"" 38 [965] 23 584 216 98' 161 '73' 251 4 337 153) ] THE CORNER WALL.3 ZT 922 418 42.4 [1077] 24.7 '627 202 92 184 '84' 255 [[116'281 "1281 5. FOR SMALLERS090 CLEARANCES24.38 . 4 ZT 960 436 42.5 [1080] 25.5 "648 217 '98 198 "90' 260 [118" 285 '129] APPLICATION ENGINEERING [613 5 20 968 '439 41.6 [1057] 25.5 '648 223[101" 196 "89 257 [117' 293 7331 6. DOWNFLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY ROOF CURB ONLY. IF UNIT IS MOUNTED SIDE SUPPLY, IT - IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED BY CROSS BRACES A5 DONE ON ACCESSORY ROOF CURBS. 32.06 7. SIDE DUCT FLANGES ARE 0.75" HIGH. BOTTOM DUCTS DO NOT HAVE FLANGES. [814] 8. MINIMUM CONDENSATION TRAP HEIGHT SHALL BE 1.5 TIMES A - 18.00 [457] 7.85 [199] i- 6.82 I (173] - - 1 THE LOWEST NEGATIVE STATIC. 9. DIMENSIONS IN [ ARE IN MILLIMETERS OR KILOGRAMS. - ---- B - COIL GUARDS,POWER EXHAUST, GAS HEAT,26.18 ECONOMIZER, DISCONNET SWITCH, CONVENIENCE OULET, [663] R E -[ S ti- 1 1 U • r la ALTERNATE CONDENSATION DRAIN 10.47 ALTERNATE [266] ■� 18.2] [464 AND BAROMETRIC RELIEF & FRESH AIR HOODS SHONN. (FROM MTG. 11. DELETED FLANGE) 12. ►E HEAT EXCHANGER IS NOT AVAILABLE FOR 3 & 4 TON UNITS. LEFT 27.50 11.1 R [699] N 24.00 P 610]q 1 ---I Y - 16.00 RIGHT [406] _ R T 27.75 / H [705 ] DIRECTION OF AIRFLOW I i >4.... N 50 CENTER OF GRAVITY 28.39 19.14 21.0] -� �Ii ., 3/4" FP [518] 20.14 [486] 17.14 [5]2]. [4[ 5] [533 t / �:-'./ _ - 12.06 ! t -.[306] ' ly It FRONT 5.32 - 14.47 BOTTOM GAS 5.16 SUPPLY ENTRY [75] .3 [ 1 [368] 16.39 2.00 [51] [131] - 27.5 31.69 BOTTOM ENTRY 18.06 [416] POWER 0 [64] [699] [805] [459] ROL 3X 00.875 [22] REAR (PARTIAL 1 33 43 (4.89 X (480] T�CON VIEN (INTAKE HOOD NOT 59000130 13105 VIEW) - OUTSIDE AIR DETAIL A DISCONNECT SWITCH COVER - OPTIONAL -- INTAKE HOOD(OPTIONAL) 89.08 POWER ENTRY 02.50 [64] [2261] [11475475 ] - _-.-- -� i' FRESH AIR HOOD/ r I i'+ ECONOMIZER(OPTIONAL) �^ �__� -1 - I FILTER/ BLOWER ACCESS _ A5 INLET 25.72 II !HU CTL PANEL jq O [653], CONTROL ENTRY 0.875 [22] ACCESSO' ACCESSI ACCESS P8068 ENTRY 2.50 [64 F- - 42.03 . _'ate [1068] ..... ILII �',.' .� I BAROMETRIC RELIEF HOOD/ . � _ • POWER EXHAUST(OPTIONAL) -o o • L11.38 I+ uL�' �a tea CONVENIENCE OUTLET COVER (OPTIONAL) / / 27.91 I 21.19 -- [694] '-SEE DETAIL A FOR [538] [289] / POWER ENTRY ¢ OUTLET [22] DRAIN. LOCATION UST 59.00 FLUE [1499] ,IL GUARD 89.00 ).EFT VIEW [2261] FRONT VIEW (OPTIONAL) (OPTIONAL FRONT COIL GUARD NOT SHOWN IN THIS VIEW) RIGHT VIEW Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 BYO Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 7 Project Name: APPLEBEES-TlJKWILLA Unit Model #: ZFO9ON18R2BIEAAIA1 Quantity: 3 Tag #: RTU -1, 2 & 3 - FACTORY BLD -5 WKS System: ZF09ON18R2BIEAA1A1 (3) Low Leak Downflow Economizer Low Leak Downflow Economizer (shown with optional Power Exhaust) Fresh Air Hood (included) Low Leak Economizer (included) Power Exhaust (optional) Barometric Relief Damper (included) Low leak economizers are capable achieving low leakage rates of 3 cfm/sq. ft at 1" of static pressure, meeting or exceeding the following standards: ASHRAE 90.1-2010 ASHRAE 62 AMCA 511 (licensed as Class 1A damper) International Energy Conservation Code (IECC) California Title 24 The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power Toss. Barometric Relief Hood (included) Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02J09/2017 gyoRK Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 8 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZFO9ON18R2B1EAA1A1 Quantity: 3 Tag #: RTU -1, 2 & 3- System: ZFO9ON18R2B1EAA1A1 (3) FACTORY BLD -5 WKS Seismic Certification 725672-UAD-A-0911 ((0)) DCL�.� .,M SPECIAL SEISMIC CERTIFICATION OF NON-STRUCTURAL COMPONENTS AND SYSTEMS CERTIFICATE OF COMPLIANCE Johnson Controls Dynamic Certification Laboratories has qualified the listed packaged rooftop units as CERTIFIED for seismic applications in accordance with the following codes and standards: CBC 2010, IBC 2009, ICC -ES AC -156 2010, ASCE 7-05 The following model designations are included in this certification. A complete list of certified models, options, and installation methods are detailed in report number90300-1107 by Dynamic Certification Laboratories, provided by the equipment manufacturer upon request. Unitary Product Group Packaged Rooftop Units (UPG) Seismic Qualification Testing was conducted in accordance with and in strict adherence to the standards set forth within the American Society of Civil Engineers (ASCE 7) by the independent approval agency, Dynamic Certification Laboratories. The above referenced equipment is APPROVED for seismic applications when properly installed and used as intended. The basis of this certification is through testing of the active and energized components per AC156. This certification covers multiple UPG brands, including York, Johnson Controls, Coleman, Luxaire, Evcon, Fraser - Johnston and Ready Ship. The seismic values are obtained from the Maximum Considered Earthquake Short Period Spectral Response Acceleration, Sds, as determined by the ASCE 7 seismic maps. Various installation locations/isolation configurations are covered under this certification, limited by the Sds value stated in the following table. A seismic importance factor, Ip, of 1.5 applies to this certification to include essential facility requirements and life safety applications for post event functionality. The units are approved for both a 14" rigid and 22" spring isolated, seismically approved roof curbs, or slab (on grade) mount. Maximum Design Sds Values of UPG Packaged Rooftop Units Series Model Tons Sds (g) Fp/Wp ZR/ZJ/ZH/ZK/ZW/ZU/JA3* 037 3 2.5 1.88 ZR/ZJ/ZH/ZK/ZW/ZU/JA4* 049 4 2.5 1.88 ZR/ZJ/ZH/ZK/ZW/ZU/JAS* 061 5 2.5 1.88 ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J06* 078 6.5 2.5 1.88 ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J07*/T* 090 7.5 2.5 1.88 ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J08* 102 8.5 2.5 1.88 ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/110*/T* 120 10 2.5 1.88 ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J12*/T* 150 12.5 2.0 1.50 Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431— ph: 77S-358-5085 Page 1 of 2 www.shaketest.com Johnson Controls Unitary Products 1 Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 9 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZFO9ON18R2B1EAA1A1 Quantity: 3 Tag #: RTU -1, 2 & 3 - FACTORY BLD -5 WKS System: ZFO9ON18R2B1EAA1A1 (3) ((0)) DCI_ mLG :i bnLbanrir� Seismic Certification SPECIAL SEISMIC CERTIFICATION OF NON-STRUCTURAL COMPONENTS AND SYSTEMS CERTIFICATE OF COMPLIANCE Johnson d Controls Table of Seismic Design Parameters Site Class Fa IP apR1, z/h D 1.0 1.5 2.5 6.0 1.0 Site and Project Requirements It is the responsibility of the Design Professional of Record to: • Provide engineering for the anchorage and restraint of the unit • Validate Certification Design Parameters with actual site conditions • Provide engineering of all equipment support structures • Confirm component configuration Certification Issued by: Dynamic Certification Laboratories Document Control Number: 90300-1107-A Issue Date: 9/2/11 mfrs o, .00 /4, it9y 55220 xa G 3 2d Dr. Ahmad Itani, SE Dynamic Certification Laboratories c, &et Randy Forristall Principal Engineer, Commercial Products YORK Unitary Engineering Johnson Controls, incorporated Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431— ph: 775-358-5085 Page 2 of 2 www.shaketest.com Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 gyoR rYoRK Predator (3-12"5N524 Ton Package) York Single Package R-410A Air Conditioner Page: 10 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZFO9ON18R2B1EAA1A1 Quantity: 3 Tag #: RTU -1, 2 & 3 - FACTORY BLD -5 WKS System: ZFO9ON18R2B1EAA1A1 (3) Component Location 6 112 Through 10 Tons Simplicity" control board Filter access wlsorew connector for T -stat Disconnect location wiring and network connections (optional disconnect switch) (2" or 4' filter options) Terminal block for hi -voltage, connection Second model nameplate inside:hinged access panel Dual stage cooling for maximum comfort 1 Compressor #2 1 access (high 111 efficiency compressor) Filter drier (solid core) Micro -Channel Aluminum Tube/Aluminum Fin Condenser v Slide -out motor and blower assembly for easy adjustment and service Belt -drive blower motor VFD location (optional) Power ventor motor 20 -gauge aluminized steel tubular heat exchanger for long life (stainless steel option) /''- x '.� ► It .r— ` Two-stage gas Base rails w/forkliftheating to maintain slots (three sides) I warm, comfortable and lifting holesSlide-out drain pan temperature with 314` NPT, female connection Intelligent control board for safe and Roof curbs in eight- and — '- '+ \ efficient operation fourteen -inch heights. Side entry power Compressor#1 access Tooliessartd control wiring (high -efficiency compressor) door latch knockouts Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02109/2017 Small Sunline (3-6 Ton Package) N543 Single Package R -410A Air Conditioner Page: 11 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZE060H12A2C1EAA1A1 Quantity: 1 Tag #: RTU4-DIR-FACTORY BLD -5 WKS System: ZE060H12A2C1EAA1A1 uooung rerrormance Total gross capacity 61.1 MBH Sensible gross capacity 45.4 MBH Total net capacity 57.8 MBH Sensible net capacity 42.1 MBH Seasonal Efficiency (at ARI) 14.00 SEER Efficiency (at ARI) 11.80 EER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 59.0 °F Leaving WB temp. 57.3 °F Power input (w/o blower) 4.28 kW Sound power 82 dB(A) Refrigerant Refrigerant type R -410A Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 100 MBH Supply air 2000 CFM Heating input capacity (Max) 125 MBH Leaving DB temp. 106.3 °F Air temp. rise 46.3 °F SSE 80.6 % Stages 1 Supply Air Blower Performance Supply air 2000 CFM Ext. static pressure 0.6 IWG Addl. Unit Losses (Options/Accessories) 0.15 IWG Blower speed 1103 RPM Duct location Bottom Motor rating 1.00 HP Actual required BHP 1.02 HP Power input 0.95 kW Elevation 0 ft. Drive type DIRECT Speed tap 5 Electrical Data Power supply 230-3-60 Unit min circuit ampacity 32 Amps Unit max over -current protection 40 Amps Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in. Weight with factory installed options 694 lbs. Clearances Right 24 in. Front 32 in. Back 36 in. Tnn 77 in lantfnm n in 1 off 2R in Note: Please refer to the tech guide for listed maximum static pressures AI CERTIFIED.. .-„..,14.••a, orgl ^A® tE� SP' QUALirr;... . us 5 Ton • York Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer -Run Tested Prior to Shipment. Unit Features • Single Stage Cooling • Single Stage Cooling • Single Stage Gas Aluminum Steel • 125 MBH Input • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117. Standards) • Either Supply and/or Retum can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels. • Full Perimeter Base Rails with Built in Rigging Capabilities • Scroll Compressor • Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, Califomia Title 24, AMCA 511) • 1 HP Direct Drive Blower • Unit Ships with 1” Throwaway Filters • Solid Core Liquid Line Filter Driers • Replacement Filters: 2 - (15" x 20" x 1" or 2") and 1 - (14" x 25" x 1" or 2"). Unit accepts 1" or 2" wide filters. • Through -the -Curb and Through -The -Base Utility Connections • Short Circuit Current: 5kA RMS Symmetrical • Single Point Power Connection • Retum Air Smoke Detector • Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil • Galvanized Steel Drain Pan • Standard Access Doors Standard Unit Controller: Simplicity Control Board • Safety Monitoring - Monitors the High and Low -Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips. • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. Allows all units to operate in the cooling mode down to 0 °F outdoor ambient without additional components or intervention. BAS Controller • Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • Ten (10) Year Warranty - Aluminized Heat Exchanger Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 Page: 12 Small Sunline (3-6 Ton layoRic., Package) N543 Single Package R -410A Air Conditioner Project Name: APPLEBEES-TUKWILLA Unit Model #: ZE060H12A2C1EAA1A1 Quantity: 1 Tag #: RTU-4-D/R-FACTORY System: ZE060H12A2C1EAA1A1 BLD -5 WKS • Factory Installed Options ZE060H12A2C1EAA1A1 • Product Category: • ZE York Small Sunline Single Packaged R -410A Air Conditioner _ . 11.8 EER / 14.0 SEER Nominal Cooling Capacity: 060 5 Ton Single Stage Cooling Heat Type and Nominal Heat Capacity: ' H12 Single Stage Gas Aluminum Steel, 125 MBH Input Airflow Options: A 1 HP Direct Drive Blower Voltage: 2 208/230-3-60 Economizer / Damper: C Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) Sensor Options: E Retum Air Smoke Detector Controls: A Simplicity® SE Controller including Discharge Air, Retum Air, and Outdoor Air Temperature Sensors Refrigeration:. A Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil Additional Options: 1 1" Throwaway Filters Cabinet Options: A Galvanized Steel Drain Pan Standard Access Doors Product Generation: Field Installed 1 Accessories 1 RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) (6.0 lbs) Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 Small Sunliine (3-6 Ton Package) N543 Page: 13 1111111WORIC Single Package R -410A Air Conditioner Project Name: APPLEBEES-TUKWILLA Unit Model #: ZE06OH12A2CIEAAIA1 Quantity. 1 Tag #: RTU-4-D/R-FACTORY BLD -5 WKS System: ZE060H12A2CIEAAIA1 Consolidated Drawing NOTES: 1. FOR R USE ONLY. 2. WEIGHTSOSHOWN 460 80R COOLING ONLY UNITS. TONNAGE U I OPERATING WEIGHT (LBS) CENTER OF GRAVITY LOCATION (BASE UNIT) 4 POINT CORNER LOADS (LBS) (BASE UNIT) 3. MIN. CLEARANCES TO 8E: T (BASE UNIT) X 0 A B C 0 RIGHT SIDE: 24 LEFT SIDE: 24 [609,6] 689,6] (LESS ECONOMIZER) 3 ZE 470 [213] 34.5 [876,3] 18.25[463,6] 111 [50] 88 [36] 117 (53) 162 [73] 36 914,4(WITH ECONOMIZER) ] 4 ZE 598 [271].- 36 [914,4] 18.50 [469,9] 139 [63] 108 [49] 154 [70] 198 [90] FRONT: 24 32 609,6 (COOLING/ELECTRIC HEAT) 812,8 HEAT) 5 ZE 632 [287] 37.5 [952,5] 18.2 [462,3] 139 [63] 117 [53] 171 [78] 204 [93]' REAR:. 12 (GAS 384,8 (LESS ECONOMIZER) 3 ZF 468 [212] 33 [838,2] 18.25 [463,6] 114 [52] 76 [35] 111 [50] 167 [76) 36: 914,4 (WITH ECONOMIZER OR FIXED 4 28 541 [245] 31.50 [800,1] 18.50 [469,9] 138 [63] 85 [39] 122 [55] 196 [89] TOP: 72 AIR/MOTORIZED DAMPER) 1828,8] 5 ZF 569 258 [ ] 37 9 ] [ 39,8 15 381 ( ) 105 48 [ ] 86 39 [ ] 170 77 [ ] '208 94 ( ] BOTTOM: 0 0] 31.6231.62 6 28 640 [290] 37 [939,8] 15 [381] 118 [54] 96 [44] 192 [87] 234 [186] 4 CONTACT FOR YOURER SERV APPLICATION�ENNGGIINEERINGNAL CLEARANCES D �C NT. [803,3] 6.12 3 ZR 575 [261] 40 [1016] 20 [508] 132 [60] 125 (57] 155 [70] 164 [74] 5. DOSOIFLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY ROOF CURB ONLY. IF UNIT IS MOUNTED SIDE SUPPLY, [155,5] 4 ZR 585 [265] 40 [1016] 20 [508] - 134 [61] 127 [58] 158 [72] 167 [76] IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED IT 7.25 BY [184,0] 18.26 [463,7] 5 ZR 590 [268]40 1816 [ ] -. 20 [508]:. 135 61 [ ] 128 58 I ] 159 [72]168 76 [ ] CROSS BRACES, A5 DONE ON ACCESSORY ROOF CURBS. 6. SIDE DUCT FLANGES ARE 8.875" [22,2] HIGH. 1.80 27.54 3 XN 618 [277] 38.3 [972,8] 18.75 [476,3] 136 [62] 119 [54] 165 (75] 190 [86] BOTTOM DUCTS DO NOT HAVE FLANGES. [45,8] [699,6] 4 Xry 616 279 [ ] 38.2 978,3 [ ] 18.4 [467,4]135 61 [ ] 117 53 [ ] 169 [77]195' 88 i. ] 7. MINIMUM CONDENSATION TRAP HEIGHT. SHALL BE 1.5 THE LOWEST NEGATIVE STATIC. TIMES - 9 REAR 5 XN 620 [281] 38.6 [980,4] 18 [457,2] 132 [68] 117 [53] 174 [79] 197 [89] 8. DIMENSIONS IN [ ] ARE IN MILLIMETERS OR KILOGRAMS. wm in 3 XP 575 [261] 39 [990,6] 20 [508] 135 [61] 121 [55] 151 [69] 168 [76] 9. OPTIONAL COIL GUARD, GAS HEAT, ECONOMIZER HOOD, DISCONNECT SWITCH, CONVENIENCE OUTLET,. AND 5.89 4 XP 585 [265]] 39 [990,6 20 508 [ ] 137 62 [ ] 124 56 [ ] 154 70 [ ] 171 78 [ ) OUTLET/INLET HOOD SH06N. 5.51 (149,6] 5 XP 590 [268] 39 [990,6] 20 [508] 138 [63] 125 [57]. 155 [70] 172 [78] ® EXCEPT XN & XP (HEAT PUMP) UNITS. [140,0] A # B _ —O. DIRECTION OF AIRFLOW 12.26 1]J CENTER OF GRAVITY POWER WIRING BOTTOM ENTRY 02.00 [50,8) .Y [3113]j —'i. L[229211. 17.58 �t ---,, �� 31111GI�T�a. i�tllllli - RIGHT.. I ECONO / a/A 3.88 11.50 .[76,2] [292,1] 4.00 [101,6] �� [44'1,5] -pna N. ` RETU/ 11.50 19.08 111111111111111111111111Y SUPPLY 0/ARN '.! [292 1] (484,6) I 8.23.. ', i [209;2]. 1 1 . - Emi . 111111 mil a , 1 D 11.06 , IItI 6.48 C ] 6.0 [16551 f `-4.58[116,3] CONTROL WIRING BOTTOM ENTRY 00.88 [22,2] [281,8] 32 09 [815,2] X [1647] , - - SUPPLY BOTTOM-ENTRY01.50 (38,1] K.O.— (0.50 [12,7] NPT AT GAS VALVE ,rte - VENT AIR OUTLET H000'Al-'l(OPTIONAL) - 17.50 (444,5] 17.50 [444,5] --- 31.62 (803,2] 7.62 [193,6] ECONOMIZER HWD 01.97 K.O. REAR (PARTIAL VIEW) [50,c DISCONNECT SWITCH. COMBUSTION COVER (OPTIONAL) ATR INLET H000 A RAIN HOOD NOT SHOWN IN THIS VIEW) � II pCCE55. • 1�.. Aill p5 HEAT{�[Ij COMP. 1. �+ ,S SI IIS 11 1 I II -__, B1047ER ACCESSSS CONVENIENCE OUTLET BLOWER ACCE55�' ACCES ��I 32.55 MINIM� S_IV 1 27.35 COVER (OPTIONAL) :r ACCESS �- [826,7] L g M I [694,7] 1 f�li 43 [ 2 2] K.O. II ' � K 1 H I SII S i' 5 1 ri��3_. fe, .cis _ � II 3.78 — [96,0] -- 4.38 .6.94 111,1] 18.58 t-- [471,9] 0.75 [19,1] PVC FPT —'19.67 —4.42 — [499,7] ],3 ] 2.55 [176,2] 44.88 31.89 GAS SUPPLY ENTRY A/� - , [1139,8] COIL GUARD [810,0]. 01.63 [41,4] 61S (OPTIONAL) RIGHT VIEW COND. DRAIN — 82.19 LEFT VIEW [64,7] [2087,6] PROW VIEW Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/092017 12YORK Small Sunline (3-6 Ton Package) N543 Single Package R -410A Air Conditioner Page: 14 Project Name: APPLEBEES-TUKW1LLA Unit Model #: ZE060H12A2C1EAA1A1 Quantity: 1 Tag #: RTU-4-D/R-FACTORY System: ZE060H12A2C1EAA1A1 BLD -5 WKS r { Typical Application ROOF JACK INSTALLATION I 1 1 ROOF CURB INSTALLATION SLAB ON GROUND INSTALLATION FIELD -SUPPLIED DISCONNECT SWITCH ROOF CURB CONDENSATE TRAP TO POWER SUPPLY CONTROL WIRING TO INDOOR THERMOSTAT RETURN AIR DUCT SUPPLY AIR DUCT MANUAL GAS SHUT-OFF VALVE 11 TO GAS SUPPLY LINE Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 BYO Small Sunline (3-6 Ton Package) N543 Single Package R -410A Air Conditioner Page: 15 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZE060H12A2C1EAA1A1 Quantity: 1 Tag #: RTU-4-D/R-FACTORY BLD -5 WKS System: ZE060H12A2C1EAA1A1 CONTACTOR. _i. GROUND LUG Typical Field Power and Control Wiring TYPICAL POWER WIRING FIELD -SUPPLIED DISCONNECT r - - -r - -t SINGLE 1- (y'i, 9- - i -> PHASE 1--6" 0--1-- POWER CONTACTOR SUPPLY —i I - I REFER TO THE ELECTRICAL DATA GROUND L TABLES TO SIZE THE DISCONNECT LUG SWITCH, OVER CURRENT PROTECTION AND WIRING. I � L L. FIELD -SUPPLIED DISCONNECT r -- --. —, -I- O p -r= 6 " p - r - -1 -O''L O- - i L J THREE PHASE POWER SUPPLY. TYPICAL COOL/HEAT CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT' UNIT TERMINAL TERMINALS STRIP TB1 24 VOLT TRANSFORMER '24 VOLT THERMOSTAT. TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING. USE A 2 STAGE COOLING THERMOSTAT. COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI STAGE THERMOSTAT1 TERMINALS UNIT TERMINAL STRIP TB1 24 VOLT TRANSFORMER TO REMOTE SENSOR IF USED ' ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL. 2 SECOND STAGE COOLING IS NOT REQUIRED ON UMTS LESS ECONOMIZER_ SECOND STAGE HEATING IS ONLY REQUIRED ON UNITS WITH A TWO STAGE ELECTRIC HEATER OR 2 STAGE GAS HEAT. REMOVE JUMPER J2 FROM TERMINALS 4 AND 9 ON JUMPER PWG CONNECTOR P6 ON UNITS WITH ECONOMIZER. TERMINALS Al AND A2 PROVIDE A RELAY OUT -PUT TO CLOSE THE OUTDOOR ECONOMIZER DAMPERS WHEN THE THERMOSTAT SWITCHES TO THE SETBACK POSITION. COOLING / HEATING (24 VOLT THERMOSTAT) THERMOSTAT1 TERMINALS ADD JUMPER UNIT TERMINAL STRIP TB1 — 0 LJ 24 VOLT TRANSFORMER 124 VOLT THERMOSTAT. TO CONTROL THE ECONOMIZER ON THE SECOND STAGE COOLING OR TO NAVE AN ELECTRIC HEAT ACCESSORY WITH TWO STAGES OF HEAT, USE A 2 STAGE COOL AND HEAT THERMOSTAT. COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT' TERMINALS UNIT TERMINAL TRANSFORMER ',ELECTRONIC PROGRAMMABLE THERMOSTAT TYPICAL. TO CONTROL THE ECONOMIZER ON SECOND STAGE COOLING, USE A2 STAGE COOL AND HEAT THERMOSTAT. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 Predator (3-12.5 Ton. Package) N524 York Single Package R -410A Air Conditioner Page: 16 Project Name: APPLEBEES TUKWILLA Unit Model #: ZFO78N12R2B1EAA1A1 Quantity: 1 Tag #: RTU-5- FACTORYBLD-5 WKS System: ZFO78N12R2B1EAA1A1 uooung rerrormance Total gross capacity 81.5 MBH Sensible gross capacity 59.5 MBH Total net capacity 76.4 MBH Sensible net capacity 54.4 MBH Efficiency (at ARI) 11.20 EER Integrated eff. (at ARI) 13.80 IEER Ambient DB temp. 95.0 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 58.8 °F Leaving WB temp. 57.1 °F Power input (w/o blower) 6.00 kW Sound power 84 dB(A) Refrigerant Refrigerant type R -410A Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 96 MBH Supply air 2600 CFM Heating input capacity (Max) 120 MBH Leaving DB temp. 94.2 °F Air temp. rise 34.2 °F SSE 80.0 % Stages 2 Supply Air Blower Performance Supply air 2600 CFM Ext. static pressure 0.7 IWG Addl. Unit Losses (Options/Accessories) 0.16 IWG Blower speed 1167 RPM Max BHP of Motor (including service factor) 2.30 HP Duct location Bottom Motor rating 2.00 HP Actual required BHP 1.61 HP Power input 1.50 kW Elevation 0 ft. Drive type BELT Electrical Data Power supply 230-3-60 Unit min circuit ampacity 33.1 Amps Unit max over -current protection 40 Amps Dimensions & Weight Hgt 42 in. Len 89 in. Wth 59 in. Weight with factory installed options 1055 lbs. Clearances Right 12 in. Front 36 in. Back 36 in. Tnn 7') in Rnttnm n in I oft 36 'n • Note: Please refer to the tech guide for listed maximum static pressures rti mj CERTIFIED 6.5 Ton • York Predator units are manufactured at an ISO 9001 registered facility and each rooftop is completely computer -run tested prior to shipment. Unit Features • Standard Cabinet with Composite Drain Pan • Two Stage Cooling • 120 MBH Input Aluminized Steel, Two Stage Gas Heat • Full perimeter base rails with built in rigging capabilities • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Reciprocating Compressor • Dry Bulb Low Leak Economizer wBarometric Relief and Hoods (Bottom or Horizontal End Return Only) with Economizer Fault Detection & Diagnostic. (Meets ASHRAE 90.1-2013, IECC 2015, Califomia Title 24, AMCA 511) • 2 HP High Static Belt Drive Blower • Unit Ships with 2" Throwaway Filters • Solid Core Liquid Line Filter Driers • Replacement Filters: 4 - (24" x 16"). Unit accepts 2" or 4" wide filters. • Short Circuit Current: 5kA RMS Symmetrical • Through -the -Curb and Through -the -Base Utility Connections • Single Point Power Connection • Retum Air Smoke Detector • Micro -Channel "all -aluminum" condenser coil, Copper tube/aluminum fin evaporator coil • Hinged Access Panels BAS Controller • IntelliSpeed control of the VFD based on stages of cooling. Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10. • Simplicity SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors Standard Unit Controller: Simplicity Control Board • Safety Monitoring - Monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, safety lockouts and re Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • Ten (10) Year Limited Warranty - Aluminized Steel Heat Exchanger Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 0 Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 17 Project Name: APPLEBEES-TUKW1LLA Unit Model #: ZFO78N12R2B1EAA1A1 Quantity: 1 Tag #: RTU-5- FACTORYBLD-5 WKS System: ZFO78N12R2B1EAA1A1 Factory Installed Options ZFO78N12R2B1EAA1A1 Product Category: •11.2 . ZF Single Packaged R -410A Air Conditioner, Standard Efficiency EER / 12.3 IEER (CV) / 13.8 IEER (IntelliSpeed) / 12.3 IEER (VAV) Nominal Cooling Capacity: 078 6.5 Ton Two Stage Cooling Heat Type and Nominal Heat Capacity: N12 120 MBH Input Aluminized Steel, Two Stage Gas Heat Airflow: R 2 HP High Static Belt Drive Blower IntelliSpeed control of the VFD based on stages of cooling (Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) Voltage: 2 208/230-3-60 Economizer / Damper: B Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Retum Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) Sensor Options: E Return Air Smoke Detector (Bottom retum only) Controls: A Simplicity@ SE Controller including Discharge Air, Retum Air, and Outdoor Air Temperature Sensors 'Micro Refrigeration: A -Channel "all -aluminum" condenser coil, Copper tube/aluminum fin evaporator coil Additional Options: 1 Standard 2" Throwaway Filters • Cabinet Options: A Standard Cabinet with Composite Drain Pan Field Installed Accessories Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 a . . . RK Predator (3-12.5 Ton Package) N524 Page: 18 York Single Package R -410A Air Conditioner Project Name: APPLEBEES-TUKWILLA Unit Model #: ZFO78N12R2BIEAAIA1 Quantity: 1 Tag #: RTU-5-FACTORYBLD-5 WKS System: ZFO78N12R2BIEAA1A1 Consolidated Drawing NOTES: I. FOR OUTDOOR USE ONLY. 106810E 0 N 1 OPE9ATIWG WEIGHT IL8S1 CEWTE9 DF 014011T 1.0741109 1081E UNITI 1 POINT 009908 LOADS IL051 109SE UNIT/ 2. WEIGHTS SHOWN ARE FOR COOLING ONLY UNITS. 3. MIN. CLEARANCES 70 8E: )BASE UNIT/ % T 4 6 C 0 RIGHT SIDE: 12 13051 6.5 IF 860 13901 - 36 1965,21 24 1609,61 200 1111 149 1681 216 1991 292 11331 LEFT SIDE: 36 [9151 FRONT: 3619151 7.5 IF 860 [3991. 38 7965,21 24 1609.67 205 1931 153 1691 223 11011 298 [1361 REAR: 36 [9151 5 IN 064 [3931 40 110161- 26 1660.41 210 1151 111 1781 217 1911 166 11211 TOP: 72 [18301 BOTTOM: 0 [0] '- 32.68 -.1 6.5 9 7.5 12 910 14131 38 [965.21 24 (609.67 212 1961 158 1721 230 01011 309 11401 4. TO REMOVE THE SLIDE -OUT DRAIN PAIN, A REAR CLEARANCE OF 1830,01 5 23 770 [3491 40 110161- 24 1609.61 172 1181 111 1641 205 1931 251 71141 60 in 11525 ,,7:(3 HOMED. IF SPACE 15 UN988I1481E. THE 6.83 1173,57 4 IN 880 13911 40 110191 26 0660,41 214 1971 171 1797 221 11007 271 (1231 DRAIN PAH CAN BE REMOVED THROUGH THE FRONT BY SEPARATING THE CORNER WALL. 24.36 ' -7 5 tR 866 13941 10 110161 26 1660.41 211 1.961 (72 7785 218 1911 267 II217 5, FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES [619,21 j + i 6.5 IR 957 14351 38 1965.21 23 1584,21 214 1977 161 1137 249 01131 333 115❑ CONTACT YOUR APPLICATION ENGINEERING DEPARTMENT. 6. DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY F ff7.85 1.5 IR 965 04301. 36 1965.21 23 1534,27 216 1961 161 1731 251 11141 337 11531 9009 CURB ROOF CURB ONLY. IF UNIT IS MOUNTED SIDE SUPPLY, IT P [!51021_..-__ [199,37 1.5 XP 120 21111 36 1965.21 23 1504,2) 206 1931 153 1697 240 11091 322 11.61 IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED BY CROSS BRACES, AS DONE ON ACCES50RY. ROOF CURBS. 7. SIDE DUCT FLANGES ARE 0.75' NIGH.,' 30.25 BOTTOM DUCTS DO NOT HAVE FLANGES. 1168.47 1 A. @@@ - - - 6.82 !173,31 - - 4 j 8. MINIMUM CONDENSATION TRAP HEIGHT SHALL 8E I.5 TIMES THE LOWEST NEGATIVE STATIC.-' 4 ' ----41 - 10.17 B ALTERNATE CONDENSATION DRAIN 1265,91 18.25 1163,61 9. DIMENSIONS IH 1 1 ARE IN MILLIMETERS OR KILOGRAMS. 26.00 [6601 R1 S 10. OPTIONAL COIL GUARDS, POWER EXHAUST, GAS HEAT, (FROM 9• ECONOMIZER. DISCONNECT SWITCH, CONVENIENCE OUTLET, FLANGE. AND BAROMETRIC RELIEF H007 SHOWN. © EXCEPT 70 [NEAT PUMP) UNITS. E 7 27 50 0 1698,51 N i N___t_ U P 24 00 p 1 [609„61 Y t •1 _ )6.00 I/06,21 RIGHT E U. 27.75 1104,91 12. 6 TUBE HEAT EXCHANGER IS NOT AVAILABLE �T XC _i �� 5 PP Y FOR 4 TON UNITS. ` s ��34rt �- � N t -� DIRECTION OF 4199178 20.39 1 ' 19.11 t I 1 12.06 (SUL ] 20 14 17.14' \ C 1533.4-111 - I'.r [306,31 (186.,21 0.10 CENTER OF GRAVITY 1517,6) [435,41 i t 1 \• • a C 5•.16 11.---2.97 I. 14.47 0) V ROW \0131,11 r- 27,5 `--807709 GAS 32.69 -1 [75.41 1367,61 (6.39 (4)6'41 OTTOM ENTRY: (698.5] 1604,91 SUPPLY NTRY 02.00 [50,8] WFno 1yA17YlA1_ VI'eWl 4.86 ( [458,81 18.89 POWER 02.50 [63.51 (INTAKE HOOD NOT SHOWN IN THIS VIEW) 479.9] CONTROL 37 00.875 122.231 OUTSIDE AIR'�v % IOP_VLll INTAKE HOOD \ - (OPTIONALI \ 5(50391107 SWI109 COVER- - 89.00 [OPTIONAL) \\ 12260,61 - - 58.09 A r�. [1415,57 - POWER ENTRY $2.50 163,51 - - -- �, ACACCESSEA - CONTROL ENTRY $0.075 (22.271 ` INLET 25.22 1653.31 1 L CTL PANEL! FILTER[ 1W COMPRESSOR BLOWER ACCESS _ t 22 004003SS 9 POWER ENTRY 02.50 [63,51 � - 477065 --A$ Ij2 7,61 1 -1.v '-_ ���E • gal POKER EXHAUS II CONVENIENCE 007507 COVER �. 27.31 IWFT � '--86909(1910 RELIEF ROOD( 1071109411 9.19 11538,21 -- L 11.32 I o v1v 1289,11 (OPTIONAL 314' 900 POWER EXHAUST (OPTIONAL) CONVENIENCE 0171.“ --/DRAIN / POWER EMT $0.015 122.231 d In 1693 61 1 SEE DETAIL A FOR EXHAUST LOCATION FLUEQ 59.00 12498,61 `'-COIL GUARD [OPTIONAL) Olt89.00 GU [2260.61 MU ° VEN [135.0] (OPTIONAL FRONT COIL GUARD HOT SHOWN IN THIS vIEWI I ( OETAO A Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/03/2017 MYORK Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 19 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZFO78N12R2B1EAA1A1 Quantity: 1 Tag #: RTU-5- FACTORYBLD-5 WKS System: ZFO78N12R2B1EAA1A1 Low Leak Downflow Economizer Low Leak Downflow Economizer (shown with optional Power Exhaust) Fresh Air Hood (included) Low Leak Economizer (included) Power Exhaust (optional) Barometric Relief Damper (included) Low leak economizers are capable achieving low leakage rates of 3 cfm/sq. ft at 1" of static pressure, meeting or exceeding the following standards: ASHRAE 90.1-2010 ASHRAE 62 AMCA 511 (licensed as Class lA damper) International Energy Conservation Code (IECC) California Title 24 The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. Barometric Relief Hood (included) Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 WYORK Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 20 Project Name: APPLEBEES TUKWILLA Unit Model #: ZFO78N12R2B1EAA1A1 Quantity: 1 Tag #: RTU -5- System: ZFO78N12R2B1EAA1A1 FACTORYBLD-5 WKS Seismic Certification 725672-UAD-A-0911 ((0)) DCL ar :na, SPECIAL SEISMIC CERTIFICATION OF NON-STRUCTURAL COMPONENTS AND SYSTEMS CERTIFICATE OF COMPLIANCE Johnson Controls Dynamic Certification Laboratories has qualified the listed packaged rooftop units as CERTIFIED for seismic applications in accordance with the following codes and standards: CBC 2010, IBC 2009, ICC -ES AC -156 2010, ASCE 7-05 The following model designations are included in this certification. A complete list of certified models, options, and installation methods are detailed in report number 90300-1107 by Dynamic Certification Laboratories, provided by the equipment manufacturer upon request. Unitary Product Group Packaged Rooftop Units (UPG) Seismic Qualification Testing was conducted in accordance with and in strict adherence to the standards set forth within the American Society of Civil Engineers (ASCE 7) by the independent approval agency, Dynamic Certification Laboratories. The above referenced equipment is APPROVED for seismic applications when properly installed and used as intended. The basis of this certification is through testing of the active and energized components per AC156. This certification covers multiple UPG brands, including York, Johnson Controls, Coleman, Luxaire, Evcon, Fraser- Johnston and Ready Ship. The seismic values are obtained from the Maximum Considered Earthquake Short Period Spectral Response Acceleration, Sds, as determined by the ASCE 7 seismic maps. Various installation locations/isolation configurations are covered under this certification, limited by the Sds value stated in the following table. A seismic importance factor, 1p, of 1.5 applies to this certification to include essential facility requirements and life safety applications for post event functionality. The units are approved for both a 14" rigid and 22" spring isolated, seismically approved roof curbs, or slab (on grade) mount. • Maximum Design Sds Values of UPG Packaged Rooftop Units Series Model Tons Sds (g) Fp/Wp ZR/ZJ/ZH/ZK/ZW/ZU/JA3* 037 3 2.5 1.88 ZR/ZJ/ZH/ZK/ZW/ZU/JA4* 049 4 2.5 1.88 ZR/ZJ/ZH/ZK/ZW/ZU/JA5* 061 5 2.5 1.88 ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/106* 078 6.5 2.5 1.88 ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J07*/T* 090 7.5 2.5 1.88 ZR/Zl/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J08* 102 8.5 2.5 1.88 ZR/Zi/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/J 10*/T* 120 10 2.5 1.88 ZR/ZJ/ZH/ZF/XP/ZK/ZW/ZU/ZS/XA/112*/T* 150 12.5 2.0 1.50 Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431— ph: 775-358-5085 Page 1 of 2 www.shaketest.com Johnson Controls Unitary Products 1 Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 taw Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 21 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZFO78N12R2B1EAA1A1 Quantity: 1 Tag #: RTU-5- FACTORYBLD-5 WKS System: ZFO78N12R2BIEAA1A1 Q)) DCL Opx,'pmkGctitk ten, rtieTiCA Seismic Certificatlon- SPECIAL SEISMIC CERTIFICATION OF NON-STRUCTURAL COMPONENTS AND SYSTEMS CERTIFICATE OF COMPLIANCE Johnson fav Controls Table of Seismic Design Parameters Site Class F, Ip . ap Rp a/h D 1.0 1.5 2.5 6.0 1.0 Site and Project Requirements It is the responsibility of the Design Professional of Record to: •.: Provide engineering for the anchorage and restraint of the unit • Validate Certification Design Parameters with actual site conditions • Provide engineering of all equipment support structures • Confirm component configuration Certification Issued by: Dynamic Certification Laboratories Document Control Number: 90300-1107-A Issue Date: 9/2/11 Dr. Ahmad Itani, SE Dynamic Certification Laboratories c ki Randy Forristall. Principal Engineer, Commercial Products YORK Unitary Engineering Johnson Controls, Incorporated Page 2 of 2 Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431 — ph: 775-358-5085 www.shaketest.com Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 wow( Predator (3-12.5 Ton Package) N524 York Single Package R -410A Air Conditioner Page: 22 Project Name: APPLEBEES-TUKWILLA Unit Model #: ZFO78N12R2BIEAA1A1 Quantity: 1 Tag #: RTU-5- FACTORYBLD-5 WKS System: ZFO78N12R2B1EAA1A1 Component Location 5.112 Through 10 Tons Simplicity* control board wiscrew connector for T -stat Disconnect location wring and network connections (optional disconnect switch) Terminal block for hi -voltage connection Second model nameplate inside hinged access panel Filter access (2" or 4" filter options) Fitter drier (solid core) Micro -Channel Aluminum Tube/Atuminum Fin Condenser 1 Slide -out motor and blower assembly for easy adjustment and service Duan stage cooling for maximum comfort Compressor #2 access (high - efficiency compressor) Base rails w/forklift slots (three sides) and lifting holes Slide -out drain pan with 3/4" NPT, female connection Roof curbs in eight- and fourteen -inch heights. Toolless door latch Side entry power and control wiring, knockouts Compressor #1 access (high -efficiency compressor) Belt -drive blower motor VFD location.(optional) Power ventor motor 20 -gauge aluminized steel tubular heat exchanger for long life (stainless steel option) Two-stage gas heating to maintain warm, comfortable temperature Intelligent control board for safe and efficient operation Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 Date 02/09/2017 • Project Name APPLEBEES-TUKWILLA Project Number NN02091701: Client /: Purchaser APPLEBEES-DON D. Guide Specification. Summary Page Small Sunline. (3-6 Ton Package) :N543 ZE060H12A2C1 EAA1A1 RTU-4-D/R-FACTORY BLD -5 WKS 'F090N18R2B1EAA1A1 '_F078N12R2B1EAA1A1 RTU 1, 28, 3 FACTORY BLD -5 WK RTU 5 FACTORYBLD5 WKS': Unitary Sales Toot v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/092017 illYORK Guide Specification for York Predator Page: 24 GENERAL Units shall be manufactured by Unitary Products in an ISO 9001 certified facility. York Predator units are convertible single packages with a common footprint cabinet and common roof curb for all 6-1/2 through 12- 1/2 ton models. All units have two compressors with independent R -410A refrigeration circuits to provide 2 stages of cooling. The units were designed for light commercial applications and can be easily installed on a roof curb, slab, or frame. All units are self-contained and assembled on rigid full perimeter base rails allowing for 3 -way forklift access and overhead rigging. Every unit is completely charged with R -410A, wired, piped, and tested at the factory to provide a quick and easy field installation. All units are convertible between side and down airflow. Independent economizer designs are used on side and down discharge applications, as well as all tonnage sizes. Units are available in the following configurations: cooling only, cooling with electric heat, cooling with gas heat, reheat only, reheat with electric heat, reheat with gas heat, heat pump and heat pump with electric heat. Electric heaters are available as factory -installed options or field -installed accessories. DESCRIPTION Units shall be factory assembled, single package, (Elec/Elec, Gas/ Elec), designed for outdoor installation. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return and be available with factory installed options or field installed accessories. The units shall be factory wired, piped and charged with R -410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. The cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA certified to ANSI 221.47 and UL 1995/CAN/CSA No. 236-M90 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel with exterior surfaces coated with a non -chalking, powder paint finish, certified at 1000 hour salt spray test per ASTM -B117 standards. Indoor blower sections shall be insulated with up to 1" thick insulation coated on the airside. Either aluminum foil faced or etastometric rubber insulation shall be used in the unit's compartments and be fastened to prevent insulation from entering the air stream. Cabinet doors shall be hinged with toolless access for easy servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, fork truck access and proper sealing on roof curb applications. Disposable 2" filters shall be fumished as standard and be accessible through hinged access door. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating bypass of the coils. Condensate pan shall be slide out design, constructed of a non corrosive material, internally sloped and conforming to ASHRAE 62-B9 standards. Condensate connection shall be a minimum of 3/" I.D. female and be rigid mount connection. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fans shall be of the direct drive type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider brackets and shall be dynamically balanced for smooth operation. The outdoor fan motors shall have permanently lubricated bearings internally protected against overload conditions and staged independently. A cleaning window shall be provided on two sides of the units for coil cleaning. REFRIGERANT COMPONENTS Compressors: a. Shall be fully hermetic type, direct drive, intemally protected with internal high-pressure relief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or —10% of the unit nameplate voltage. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, draw-thru design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro -Channel. aluminum tube, aluminum fins. Special Phenolic coating shall be available as a factory option. d. Condenser coils shall be of the draw-thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed -orifice or thermally operated expansion devices. b. Solid core filter drier/strainer to eliminate any moisture or foreign matter. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 s ll° YORK Guide Specification for York Predator Page: 25 c. Accessible service gage connections on both suction d. and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The unit shall have two independent refrigerant circuits, equally split in 50% capacity increments. Unit Controls: a. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24 -volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit should any of the following standard safety devices trip and shut off compressor: • Loss-of-charge/Low-pressure switch. • High-pressure switch. • Freeze condition sensor on evaporator coil. If any of these safety devices trip, the LCD screen will display the alarm message. c. Unit shall incorporate "AUTO RESET" compressor over temperature, over current protection. d. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. e. Unit control board shall have on -board diagnostics and fault message display. f. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation down to a selectable value as low as 0 °F. Control board shall monitor each refrigerant safety switch independently. g. GAS HEATING SECTION Heat exchanger and exhaust system shall be constructed of aluminized steel and shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 40 °F. Burners shall be of the in -shot type, constructed of aluminum -coated steel: All gas piping shall enter the unit cabinet at a single location, through either the side or bottom, without any field modifications. An integrated control board shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection: a. Primary and auxiliary high-temperature limit switches. b. Induced draft pressure sensor. c. Flame proving controls. All two stage gas units shall have two independent stages of capacity (70% or 75% 1st stage, 100% 2nd stage) 3 through 5 ton and (60% 1st stage, 100% 2nd stage) 6-1/2 through 12-1/2 ton. UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125 °F outdoor temperature, exceeding maximum load criteria of AHRI Standard 340/360. The compressor,with standard controls, shall be capable of operation down to 0 °F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up. (Gas heat only) ELECTRICAL REQUIREMENTS - All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES - Compressor — 5 Years, Heat Exchanger —10 Years, Stainless Steel Heat Exchanger -15 Years, Elect. Heat Elem. — 5 Years, Parts —1 Year. FACTORY INSTALLED OPTIONAL OUTDOOR AIR (Shall be made available by either/or): • ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER — Outdoor and retum air dampers that are interlocked and positioned by a fully - modulating, spring -return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall be designed to meet ASHRAE 90.1- 2010, AMCA 511 Class 1A dampber, and the International Energy Conservation Code (IECC) certification requirements by achieving leakage rates of 3 cfm/sq. ft. at 1" of static pressure. During economizer operation, a mixed -air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55 °F. Changeover from compressor to economizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. ADDITIONAL FACTORY INSTALLED OPTIONS Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 Guide Specification for York Predator Page: 26 • Alternate Indoor Blower Motor — For applications with high restrictions, units are available with optional indoor blower motors that provide higher static output and/or higher airflow. • IntelhSpeedTM Supply Fan Control Option. (ASHRAE 90.1 compliant, section 6.4.3.10) — Units configured with the IntelliSpeed'TM Supply Fan Option will contain a VFD for variable volume supply fan operation. This option allows the supply fan RPM to vary based on the number of compressors or heating stages energized. The economizer's minimum position will also be configurable to vary based on the supply fan VFD frequency output. • BAS Controls — Include supply air sensor, return air sensor, dirty filter indicator and air proving switch. • Smoke Detector — A smoke detector can be factory mounted and wired in the supply and/or retum air compartments. FIELD INSTALLED OPTIONS Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 1YO•RIt Guide Specification for York Sunline Page: 27 GENERAL Units shall be manufactured by Johnson Controls Unitary Products in. an ISO 9001 certified facility. York Sunline units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab -mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory -mounted options and field -installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and retum air panels on the rear of the unit. All non -Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter -drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24 -volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1 -year limited warranty on the complete unit. Compressors and electric heater elements carry a 5 - year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10 -year warranty. DESCRIPTION Units shall be factory -assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat are designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have 11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0 EER. They shall have built-in field convertible duct connections for down discharge supply/retum or horizontal discharge supply/retum, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R -410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non -chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate. either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self -draining standards. Condensate connection shall be a minimum of 3/4" I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed direct -drive or belt -drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double -inlet type with forward -curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct -driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 YORK Guide Specification for York Sunline Page: 28 REFRIGERANT COMPONENTS Compressors: a. Shall be intemally protected with internal high- pressure relief and over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, draw-thru design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro -Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the direct expansion, draw-thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed -orifice or thermally operated expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The refrigeration system shall provide at least 15°F of sub -cooling at design conditions. Unit Controls: a. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24 -volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze -protection thermostat, evaporator coil. f. Unit shall incorporate "AUTO RESET" compressor over temperature, over current protection. g. h. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. Unit control board shall have on -board diagnostics and fault code display. i. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation downto0°F. Control board shall monitor each refrigerant safety switch independently. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. 1• k. GAS HEATING SECTION Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection. a. Primary and auxiliary high-temperature limit switches. b. Induced draft motor speed sensor. c. Flame roll out switch. d. Flame proving controls. e. If any of the above safety devices trip, a LED (light - emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 Guide Specification for York Sunline Page: 29 ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year OPTIONAL OUTDOOR AIR • Economizer — Outdoor and return air dampers that are interlocked and positioned by a fully -modulating, spring return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit -mounted potentiometer shall be provided to adjust the outdoor and retum air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed -air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. ADDITIONAL FACTORY INSTALLED OPTIONS • BAS Controls FIELD INSTALLED OPTIONS • Barometric Relief Damper — This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. Unitary Sales Tool v1.5.9.0 Information is subject to change without notice. Check local codes. Printed 02/09/2017 5/1/2018 City of Tukwila Department of Community Development JOHN HOWARD 11227 217 ST CT E SPANAWAY, WA 98338 RE: Permit No. M17-0060 APPLEBEES 17790 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if ' the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/12/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request. Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/12/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, r Bill Rambo Permit Technician File No: M17-0060 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 11/2/2017 City of Tukwila Department of Community Development JOHN HOWARD 11227217 ST CTE SPANAWAY, WA 98338 RE: Permit No. M17-0060 APPLEBEES 17790 SOUTHCENTER PKWY Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the Issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 12/12/2017. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If ft is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 12/12/2017, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File No: M17-0060 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Noah Noaker Northwest Branch 3985 70th Ave East Ste -D-1 Fife, WA 98424 Date: 2/9/2017 Proposal Number:NN02091701 To: APPLEBEES-DON D. Project Name: APPLEBEES-TUKWILLA PROPOSALt LJ YORK® INSTALL CONFIDENCE Direct Line -Phone: 425-245-9095 Lynnwood Branch: 888-524-2203 E-mail: noah.a.noaker@ici.com QTY TAG # MODEL NO. DESCRIPTION EXTENSION 3 RTU -1, 2 & 3- FACTORY BLD -5 WKS ZFO9ON18R2B1EAA1A1 7.5 Ton, Two Stage Cooling, Single Packaged R -410A Air Conditioner, Standard Efficiency, 11 EER / 12.2 IEER (CV) / 13.5 IEER (Intellispeed) / 12.2 IEER (VAV), 180 MBH Input Aluminized Steel, Two Stage Gas Heat, 208/230-3-60 • Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Return Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) • 3 HP High Static Belt Drive Blower • Standard 2" Throwaway Filters • Simplicity@ SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors • IntelliSpeed control of. the VFD based on stages of cooling (Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) • Return Air Smoke Detector (Bottom return only) • Micro -Channel "all -aluminum" condenser coil, Coppet_ tube/aluminum fin evaporator coil RECEIVED • Standard Cabinet with Composite Drain ParCITY OF 1 UKWILA',550.66 3 5 DAYS CDI-1-9999-5035 Curb Adapter MAY 1 2011 Old Model: DAUS-T090-7.5 TON "� New Model: ZFO90-7.5 TON Top Brace; Insulated Condenser Panel (where�I'r' CENTER required); Fully Insulated (1"" Duct Liner R Valug3 $ 3,000.00 1 RTU-4-D/R- FACTORY BLD -5 WKS CORRE TION LTR# 5 Ton, Single Stage Cooling, York Small Sunline Single Packaged R -410A Air Conditioner, 11.8 EER / 14.0 SEER, 125 MBH Input, Single Stage Gas Aluminum Steel, 208/230-3-60 • Dry Bulb Economizer and Hood (No Barometric Relief Damper) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) • 1 HP Direct Drive Blower • 1" Throwaway Filters • Simplicity@ SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors • Return Air Smoke Detector • Microchannel All Aluminum Condenser Coil, Copper tube/Aluminum fin Evaporator Coil • Galvanized Steel Drain Pan • Standard Access Doors $ 4,463.72 ZE060H12A2C1EAA1A1 1 1 RD0410 Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) $ 78.40 M(7ooC Quote based on 1 -Shipment to 1 -Location ONLY. Multiple shipment may incur additional freight charges. Signed copy of the approved proposal required prior to ordering. Tax is NOT included in this Proposal and will be added if applicable. f Equipment will be ordered as shown. Customer responsible for verifying above quoted models before equipment is ordered. If any different/ additional unit opti tt EXCLUDED: Any AND ALL unmentioned equipment, unit options, accessories, parts, or materials including (but not limited to) adapter curbs, vibration isolatioi ALL SALES OF GOODS AND SERVICES ARE CONDITIONED UPON AND EXCLUSIVELY SUBJECT TO THE YIC GLOBAL TERMS AND CON WE PROPOSE hereby to furnish material -complete in accordance with the above listing. ACCEPTANCE OF PROPOSAL The above prices and conditions are satisfac Authorized Signature Authorized Signature: Noah Noaker Date of Acceptance: These Prices are valid for not more than THIRTY (30) days from the date of the Proposal unless noted otherwise. By signing this proposal, you are accepting and approving the purchase of the items as they appear on this document. You acknowledge that the above listed Terms and Conditions have been read and understood by yourself, or an authorized representative of the entity purchasing such listed equipment. RECEIVED CITY OF TUKWILA t4AY 17 2011 PERMIT CENTER I 6.b I on, I wo Stage Cooling, Single P^-':aged H-41 UA Air Conditioner, Standard Efficiency, 11.. R / 12.3 IEER (CV) / 13.8 IEER (Intellispeed) / 12.3 IEER (VAV), 120 MBH Input Aluminized Steel, Two Stage Gas Heat, 208/230-3-60 • Dry Bulb Low Leak Economizer w/Barometric Relief and Hoods (Bottom or Horizontal End Return Only) with Economizer Fault Detection & Diagnostic (Meets ASHRAE 90.1-2013, IECC 2015, California Title 24, AMCA 511) • 2 HP High Static Belt Drive Blower • Standard 2" Throwaway Filters • Simplicity@ SE Controller including Discharge Air, Return Air, and Outdoor Air Temperature Sensors • IntelliSpeed control of the VFD based on stages of cooling (Provides Single Zone VAV Fan Operation as defined by ASHRAE 90.1 section 6.4.3.10) • Return Air Smoke Detector (Bottom return only) RTU-5- • Micro-Channel "all-aluminum" condenser coil, Copper FACTORY tube/aluminum fin evaporator coil 1 BLD-5 WKS ZFO78N12R2B1 EAA1A1 • Standard Cabinet with Composite Drain Pan $ 5,363.11 Curb Adapter Old Model: DUC076-6 TON New Model: ZF078-6.5 TON Top Brace; Insulated Condenser Panel (where required); Fully Insulated (1"" Duct Liner R Value 3.85) 1 5 DAYS CDI-1-5005-5035 $ 740.00 SUBTOTAL: $ 31,195.89 TAXES/ FEES: $ - FREIGHT: $ - TOTALTT: $ 31,195.89 Quote based on 1 -Shipment to 1 -Location ONLY. Multiple shipment may incur additional freight charges. Signed copy of the approved proposal required prior to ordering. Tax is NOT included in this Proposal and will be added if applicable. f Equipment will be ordered as shown. Customer responsible for verifying above quoted models before equipment is ordered. If any different/ additional unit opti tt EXCLUDED: Any AND ALL unmentioned equipment, unit options, accessories, parts, or materials including (but not limited to) adapter curbs, vibration isolatioi ALL SALES OF GOODS AND SERVICES ARE CONDITIONED UPON AND EXCLUSIVELY SUBJECT TO THE YIC GLOBAL TERMS AND CON WE PROPOSE hereby to furnish material -complete in accordance with the above listing. ACCEPTANCE OF PROPOSAL The above prices and conditions are satisfac Authorized Signature Authorized Signature: Noah Noaker Date of Acceptance: These Prices are valid for not more than THIRTY (30) days from the date of the Proposal unless noted otherwise. By signing this proposal, you are accepting and approving the purchase of the items as they appear on this document. You acknowledge that the above listed Terms and Conditions have been read and understood by yourself, or an authorized representative of the entity purchasing such listed equipment. RECEIVED CITY OF TUKWILA t4AY 17 2011 PERMIT CENTER May 10, 2017 City of Tukwila Department of Community Development JOHN HOWARD 11227 217 ST CTE SPANAWAY, WA 98338 RE: Correction Letter # 1 MECHANICAL Permit Application Number M17-0060 APPLEBEES - 17790 SOUTHCENTER PKWY Dear JOHN HOWARD, Allan Ekberg, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. An correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING - M DEPARTMENT: KC ELLIS at (206)-431-3677 if you have questions regarding these comments. • Provide a copy of contractor's bid sheet, include cost of HVAC units. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. M17-0060 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PERMIT COORD COPY:: PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0060 DATE: 05/17/17 PROJECT NAME: APPLEBEES SITE ADDRESS: 17790 SOUTHCENTER PKWY Original Plan Submittal Revision # . before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: V(iAw& SlIg 11 Building Division Public Works ❑ Fire Prevention Structural Planning Division ❑ ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/18/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/15/17 Approved Corrections Required ❑ Approved with Conditions ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0060 PROJECT NAME: APPLEBEES DATE: E 05/02/17 SITE ADDRESS: 17790 SOUTHCENTER PKWY X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: v -et Wiz -14-17 Building Division Public Works AA MA, S -s-17 Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 05/04/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Corrections Required— Denied (corrections entered in Reviews (ie: Zoning Issues) DUE DATE: 06/01/17 Notation: REVIEWER'S INITIALS: DATE: [Permit Center Use Only CORRECTION LETTER MAILED: 5 w Departments issued corrections: Bldg ►i' Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 5-17-17 Plan Check/Permit Number: ❑ Response to Incomplete Letter # Response to Correction Letter # ❑ Revision # after Permit is Issued 0 Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: 1 % 790-SOt)T�"/ heli J T -e- '11-(4 ^/ ,GL M 17- 0,0.6 Contact Person:�r £1C1(4Wc -. Phone Number: 1 S 3 3'11 — Summary of Revision: c os_ prof d-sdi f'(t v rri .v1l RECEIVED MAY 1 / 2017 Sheet Number(s): "Cloud"or highlight all areas of revision including dte of revisio �\....,ei----2 Received at the City of Tukwila Permit Center by: IR— Entered in Permits Plus on 8 ( /-- 1 7 H:Wpplications\Forms-Applications On Line\2010 Applications\7-2010 - Revision Submittal.doc Created: 8-13-2004 Revised: 7-2010 PACIFIC REFRIGERATION UNI ' -TD Home Espanol Contact Search L&I A -Z Index Help Page 1 of 2 Safety & Health Claims & Insurance Workplace Rights Trades & Licensing 0 Washington State Department of Labor & Industries PACIFIC REFRIGERATION UNLMTD Owner or tradesperson Principals Sokirkin, Aleksey P, PARTNER/MEMBER Doing business as PACIFIC REFRIGERATION UNLMTD WA UBI No. 603 252 618 11227 217th St Ct E GRAHAM, WA 98338-6455 253-292-8728 PIERCE County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. PACIFRU831JO Effective — expiration 04/20/2017— 04/20/2019 Bond Ohio Cas Ins Co $12,000.00 Bond account no. 32S383356 Received by L&I Effective date 04/20/2017 04/17/2017 Expiration date Until Canceled Insurance Sentinal Insurance Company LTD Policy no. 01SBARG6282 $1,000,000.00 Received by L&I Effective date 04/20/2017 10/17/2016 Expiration date 10/17/2017 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LAI Tax debts No LAI tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603252618&LIC=PACIFRU831 JO&SAW= 5/22/2017 2 14: 13:41 1996 1� r6 rOCN 11.5 (Att. <f 1 Q. .fp -J 26 1. GAS LINE AND SUPPORT, REFER TO SHEET M5 2. WATER HEATER FLUE 3. INSTALL TAPERED INSULATION TO PROVIDE POSITIVE SLOPE TO SCUPPERS 4. GALVANIZED METAL LEADER HEAD AND DOWNSPOUT TO STANDARD DETAIL SD -36.1 5. • ICE MACHINE CONDENSERS ON CURBS REFER TO STANDARD DETAIL SD -26. CURBS PROVIDED AND INSTALLED BY GENERAL CONTRACTOR 6, NOT USED 7. AWNING AND FRAME 8. ROOF TOP UNIT #5 9. ROOF TOP' UNIT #2 • ' 10. ROOF TOP UNIT 3 11. ROOF TOP UNIT 4 12. ROOF TOP UNIT 1 13. MAKE-UP AIR UNIT 14. ROOF HATCH 15. HOOD EXHAUST FAN #1 16. HOOD EXHAUST FAN #2 17. PENETRATION THROUGH ROOF FOR GAS UNE, REFER TO SHEET P4 18. WALK-IN COOLERS AND FREEZER COMPRESSOR/CONDENSERS (3) ON CURBS REFER •TO STANDARD DETAIL SD -26 CURBS PROVIDED AND INSTALLED BY GENERAL CONTRACTOR 19. RESTROOM EXHAUST FAN 20. DISHWASHER EXHAUST FAN 21. GAS LINE TO ROOF NOT USED 23. NOT USED 24: VENT, SEE 'SHEET P1 25. LIGHT FIXTURES, SEE SHEET. E-3 26. ROOF WALKWAY PADS s EXI`. HEAT INC PUMP • SLOPE 11111� EXISTING RIDGE EXISTING RIDGE EXISTING HEAT PUMP EXISTING HEAT PUMP SLOPE NOT USED 28. NOT USED 29. NOT USED 30. HATCHING DENOTES- NEW ROOF TO MATCH EXISTING - SLOPE TO SCUPPERS. 31. GREASE CONTAINMENT SYSTEM: GREASE GUARD INC.. 800-284-8273 (PROVIDED AND INSTALLED' 8Y OTHERS) 32. COORDINATE PENETRATION FOR . REFRIGERANT LINES WITH INSTALLER 33. APPLEBEE'S SIGNAGE- SEE ELEVATIONS; SHEET A2. ' • 34. INFILL ALL HOLES , IN DECKING AS NECESSARY W/ MATERIAL TO MATCH EXISTING. ' • EXISTING ROOF TO REMAIN PATCH HOLES & • FLASH NEW PENETRATIONS. 36 . Code, 1=d( 4161,E _ Z,4' (:� l Gi c,ri5 4l CuV'�2k t 37: PimI fek ca4o turi tic -'.S . A(4-- wtn. ' Pt ree-u_rr c2 aj igesiA,LCIAVIS 6 E k . u-ta,i f 's reAt (4(c ;oG Z• C n,t c f FA. f s¢e �r V(d . tic 2� u F2-61 -t- 26 21---C 26 ,JUNI2 - 4 CAN i'+;ir3f,�!?4zA•'k.3%2'^�izw_�z.��,,`s_3.�'��-�:r_'"�__`_;j 26 „e- • (... ..-=----I - - - `DL.nG. xI fi L e SC 1 I L P `i .IIT. REQUIP-r FOB: 0 Mechanical Eifjlectrical ('Gas Piping City of Tukwila BUILDING DIVISION 100 IT I/14M_ Peri, �t No. CANTILEVER AREA OF FACADE - I 61=6, CI 9 Neighborhood Grill & Bar C18 Plan revani i ' p t_':.7;i i6 subject to errors and omissions. Approval of conE i:cion documents does not. authorize the violation of any adopted code or ordinance. Receipt of approved Fk.. d Coiy a • conditions is acknowledged: 25 RECEIVED CITY OF TUKWILA MAY 022017 PERMIT CENTER ROOF By: Date: AN 5Z2 /74 City of Tukwila BUILDING DIVISION REVISIONS i No changes shall Ili made to the scope of work withmil: prior approval of Tukwila Biti!C+Ing Division. . ItiOT;". Rex;slCi ic, will I`c qtllri?�+ ri=;'•'U plan submittal and may in7.`ud,a e.c,'tional plan re,,;sv,/ fees i GENERAL NOTES: 1. G.C., STRUCTURAL AND HVAC CONTRACTORS TO COORDINATE WITH SHEET M-1. CONTRACTOR TO INSTALL SADDLES ON UPSLOPE SIDE OF ROOFTOP EQUIPMENT AS REQUIRED. • REMOVE ALL EXISTING ROOF TOP EQUIPMENT -AND PATCH OPENINGS WATERTIGHT. SEE DETAILS 11 & 12 / S-5 FOR PARAPET BRACING. M 17 -6 0 6d REVIEWED FOR CODE COMPLIANCE APPROVED MAY 18 2017 City of Tukwila BUILDING DIVISI 17790 SOUTH CENTER PARKWAY TUKWIL_A, WA JOB #: 94220 This document, and all plans, specifications,and other information contained therein, oro the exclusive property of APPLEBEE'S INTERNATIONAL, INC. These documents are - delivered and accepted, by you in trust and on the expressed condition that neither these documents or the information contained therein will be copied, reproduced, or delivered to others, except copies stomped CONFIDENTIAL - NOT FOR CONSTRUCTION/PROPERTY OF APPLEBEE'S INTERNATIONAL, INC.` No reproducible copies (sepias) shot! be distributed without the express- written consent of APPLEBEE'S INTERNATIONAL, INC. The design represented by these documents and plans is the oxclusive property, design, and concepts of APPLEBEE'S INTERNATIONAL,INC. and may not be used or copied without the express written consent of APPLEBEE'S INTERNATIONAL, INC. These documents and oil copies .will be returned to APPLEBEE'S INTERNATIONAL, INC. upon its request. • APPLEBEE'S INTERNATIONAL, INC. d 1994 Aria Group Architects Inc.. NORTH 1100 West Lake_ St. Suite 140 Oak Park, Illinois 60301 708.445.8400 Fax 708.445 1788 . LIMITS OF NEW ROOFING ADDED TO PLAN PER REVISION A . BID DATE: REVISIONS PERMIT 03/02/95 bet -16T- 31 11115 DECEMBER 15, 1994