Loading...
HomeMy WebLinkAboutPermit M17-0161 - DOWNING RESIDENCE - GAS FURNACEDOWNING RESIDENCE 4610 160 ST M17-0161 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL OTC PERMIT 2223049100 Permit Number: M17-0161 4610 S 160TH ST Project Name: DOWNING RESIDENCE Issue Date: 11/2/2017 Permit Expires On: 5/1/2018 Owner: Name: Address: Contact Person: Name: DOWNING GARY VICTOR 4610 S 160TH ST, TUKWILA, WA, 98188 JAIMIE HOW Address: 4601 S 134TH PL , TUKWILA, WA, 98168 Contractor: Name: BRENNAN HEATING & A/C LLC Address: 4601 S 134TH PL , TUKWILA, WA, 98168-3240 License No: Lender: Name: Address: BRENNHA971R9 Phone: (206) 248-7900 Phone: (206) 248-7900 Expiration Date: 12/29/2017 DESCRIPTION OF WORK: REPLACE EXISTING GAS FURNACE - LIKE FOR LIKE. Valuation of Work: $1,589.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $187.80 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: HIGHLINE Sewer District: NONE Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 Permit Center Authorized Signature: National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: <ipv 2014 2014 2014 2015 Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local I ws r gulating construction or the performance of work. I am authorized to sign and obtain this development permi and agree to the conditi®ns attached to this permit. Signatur \ Print Nam" )O Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. 5: Except for direct -vent appliances that obtain all combustion air directly from the outdoors; fuel -fired appliances shall not be located in, or obtain combustion air from, any of the following rooms or spaces: Sleeping rooms, bathrooms, toilet rooms, storage closets, surgical rooms. 6: Equipment and appliances having an ignition source and located in hazardous locations and public garages, PRIVATE GARAGES, repair garages, automotive motor -fuel dispensing facilities and parking garages shall be elevated such that the source of ignition is not less than 18 inches above the floor surface on which the equipment or appliance rests. 7: Type 1 Hoods, the required grease duct leakage test and light test shall be performed by a special inspection and testing agency in accordance with I.M.C. Chapter 5. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. Atiti `" 0101 Project No. .. /} Date Application Accepted: II ` Y'1r/ Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 4610 S 160th St Tukwila 98188 Tenant Name: King Co Assessor's Tax No.: 2223049100 Suite Number: Floor: PROPERTY OWNER Name: Brennan Heating Address: Same as Contractor Name: Gary Downing Phone: Fax: Email: Address: SAA Phone: (206) 248-7900 Fax: (206) City: State: Zip: CONTACT PERSON — person receiving all project communication Name: Brennan Heating Address: Same as Contractor City: State: Zip: Phone: Fax: Email: New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Brennan Heating Address: 4601 S 134th P1 City: Seattle State: WA Zip: 98168 Phone: (206) 248-7900 Fax: (206) 248-7905 Contr Reg No.: BRENNHA971 R9 Exp Date: 12/29/2017 Tukwila Business License No.: Valuation of project (contractor's bid price): $ 1,589 Describe the scope of work in detail: Replace existing gas furnace, Like for Like Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\ApplicationsWorms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Mt Type' Q Furnace <100k btu 1 Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm nit Tye Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — conun/industrial Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Quer/Compressor 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-10PM, Monday through Friday and 8AM-10PM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (lam -1 Opm); • Testing of backup generators during the day. NO Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF .' R ' Y BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN OW ER OR AUTHOR' . D AGENT: Signature. , Date: 10/27/2017 Print Na , aimie How Day Telephone: (206) 248-7900 Mailing Address: 4601 S 134th P1 13:\Applications\Forms-Applications On Line\2016 Applications \Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Seattle WA 98168 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK 1 ACCOUNT QUANTITY PAID $187.80 M17-0161 Address: 4610 S 160TH ST Apn: 2223049100 $187.80 Credit Card Fee $5.47 Credit Card Fee 1 R000.369.908.00.00 0.00 $5.47 MECHANICAL $173.65 PERMIT FEE R000.322.100.00.00 0.00 $140.50 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 TECHNOLOGY FEE $8.68 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12717 R000.322.900.04.00 0.00 $8.68 $187.80 Date Paid: Thursday, November 02, 2017 Paid By: JAIMIE HOW Pay Method: CREDIT CARD 04905G Printed: Thursday, November 02, 2017 12:03 PM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit 11/117-01(21 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-367 Permit Inspection Request Line.(206) 438-9350 Project: Dt weV/NG- /Z z e Type of Inspection: Aall6i1 714 ECI-f%WC/ k -Z Address:_ O s, /60,w 5s, Date Called: Special Instructions: Heft %4C: fR/Vl Date Wanted: //-491—/ a.m� Requester: Phone No: Approved per applicable codes. [] Corrections required prior to approval. COMMENTS: v%- 41€C17/4/1//e/le / Ok • n'IKChANICA-L F/Iyz Inspector: cp_5- Date: If 7 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. BRENNAN HEATING & A/C LLr Horne Espanol Contact Safety & Health Claims & Insurance Washington State Department of IL) Labor & Industries Page 1 of 2 Search L&I A -Z Index Help My L&I Workplace Rights Trades & Licensing BRENNAN HEATING & A/C LLC Owner or tradesperson Principals ERDAHL, DARRIN PAUL, PARTNER/MEMBER Doing business as BRENNAN HEATING & A/C LLC WA UBI No. 602 346 866 4601 S 134TH PL SEATTLE, WA 98168 206-248-7900 KING County Business type Limited Liability Company Governing persons DARRIN P ERDAHL ERIC L BEARDEMPHL; JAMES JOLLY; STEFANIE ERDAHL; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. BRENNHA971R9 Effective — expiration 12/29/2003-12/29/2017 Bond ................. FEDERATED MUTUAL INS CO Bond account no. 9127230 Active. Meets current requirements. $12,000.00 Received by L&I Effective date 11/04/2004 12/22/2004 Expiration date Until Canceled Insurance ..._...__.................. Federated Mutual Ins Co $1,000,000.00 Policy no. 9820726 Received by L&I Effective date 06/06/2017 07/13/2015 Expiration date 07/13/2018 Insurance history Savings ................... No savings accounts during the previous 6 year period. i Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602346866&LIC=BRENNHA971 R9&SAW= 11/02/2017