HomeMy WebLinkAboutPermit M17-0164 - BOEING #9-110 - OFFICE HEAT PUMP AND DUCTWORKBOEING #9-110 OFFICE TI 9725 E MARGINAL WAY S BLDG 9-110 M17-0164 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0003400018 Permit Number: M17-0164 9725 E MARGINAL WAY S BLDG 9-110 Issue Date: 11/22/2017 Permit Expires On: 5/21/2018 Project Name: BOEING #9-110 OFFICE TI Owner: Name: BOEING COMPANY THE Address: PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 Contact Person: Name: CONNIE HARDIN Address: 4600 S 134 PL, SEATTLE, WA, 98168 Contractor: Name: HOLADAY PARKS INC Address: 4600 S 134 PL , SEATTLE, WA, 98168 License No: HOLADPI379NO Lender: Name: Address: 11 I Phone: (206) 250-4530 Phone: (206) 248-9700 Expiration Date: 9/3/2019 DESCRIPTION OF WORK: INSTALLING HEATPUMP AND ASSOICATED DUCTWORK Valuation of Work: $50,000.00 Type of Work: REPLACEMENT Fuel type: Fees Collected: $889.67 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: VALLEY VIEW,TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: Permit Center Authorized Signature:&lab Date: 2014 2014 2014 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or lo aws reg ating construction or the performance of work. I am authorized to sign and obtain this develop Iril►�Wa : agr to t e conditions a ett d to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 11: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 12: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: ***MECHANICAL PERMIT CONDITIONS*** 17: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 18: Manufacturers installation instructions shall be available on the job site at the time of inspection. 19: The attached set of mechanical plans have been reviewed by The Tukwila Fire Marshals Office and are acceptable with the following concerns: 20: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2437) 21: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 22: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2437) 23: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2437) 24: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2437) (IFC 901.2) 25: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 26: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2436 and #2437) 27: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 28: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL /4.—() CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Tr Mechanical Permit No. V\ 11' 0Ili Project No. Date Application Accepted: Date Application Expires: 1I( (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name:_ King Co Assessor's Tax No.: 00O3(.14001 Suite Number: Floor: New Tenant: ❑ Yes tt `o PROPERTY OWNER Adddres CONTACT PERSON — person receiving all project communication Name: • 11rnQ_ 1'' .t tt1 Address: LIs r }j* 91 State: 1.001/4._ t City: stack Zipettudi/ Fax; in Zci x tto 5.30 j Emai ::mm/11%C \'‘ ( Ylhlir►. 4. f nctiks.cost MECHANICAL CONTRACTOR INFORMATION Company N ame: ci)a—r C5 Address; 1 0 DD s 1 .' Pt.A 61 t City: SIt State:])L. ziirm.g' L PV10 2s Li rid F lage r7, b Contr Reg No I..IQ'bpi..slci U_ F.�cp Date: a_ utq U Tukwila Business License No.: Valuation of project (contractor's bid price): $_ 5-0 XV_ Describe the scope of work in detail"-ys\`Ly �j�.r %"1- S SO • A 11t �•/` mak. Use: Residential: New ❑ Replacement 0 Commercial: New 0 Replacement Fuel Type: Electric 0 Gas 0 Other: li:\Applicatinnslpome-Applic tions On Line12011 Applieations\Meelmnical Permit Application Revised 8.9.1 l.doc Revised: August 2011 bb Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace>100k btu Floor furnace Suspended/wall/floor ■ I mounted heater • "Hance vent Repair or addition to heatirefrig/cooling s stein Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator —domestic incinerator — conun/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in alt cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the pennit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 clays following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED TFIJS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ,t ; R Q h`rti.iT ' OR ZED AG T: Signature: --— Print Name: 'I ( t - ' ,t f Mailing Address: k/ Q(,) . (, H'+ApplicationsWorme-Applications On Line\2013 ApplicationstMechanical Permit Application Revised 5--11.docx Revised: August 2011 bh Day Telephone: State Zip City Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $889.67 M17-0164 - Address: 9725 E MARGINAL WAY S BLDG 9-110 Apn: 0003400018 $889.67 Credit Card Fee $25.91 Credit Card Fee R000.369.908.00.00 0.00 $25.91 MECHANICAL $830.54 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $631.28 PLAN CHECK FEE R000.322.102.00.00 0.00 $166.11 TECHNOLOGY FEE $33.22 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12733 R000.322.900.04.00 0.00 $33.22 • $889.67 Date Paid: Monday, November 06, 2017 Paid By: CONNIE HARDIN Pay Method: CREDIT CARD 00734G Printed: Monday, November 06, 2017 12:13 PM 1 of 1 CRWSYsnms INSPECTION NO. INSPECTION RECORD Retain a copy with permit /'1r7- 0141 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: .80,67/Y 6- q'//V Type of Inspection: ��ciU 44 m=r/miicit- i 6it—fs- Address:Date 9725 �� %G/rf. k# Called: Special Instructions: Date Wanted: a.m. Requester: ,(, 7eiii /+'uLS'/ Phone No: 2.07-9q8 -6,3 / Approved per applicable codes. L Corrections required prior to approval. COMMENTS: C- / 'C C4 -1_.:._- R0t'6J//# 61-C rb C// Inspector: Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IP INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 Project: / a.'~✓l►� y o Type of Inspection: Rc & r11i-c4f icAl_ Address: 9725 -, m/ I -1– Wt Date Called: Special Instructions: ACE 7 /i Date Wanted: I' -2-5.-!o Ca.m.. P.m. Requester: Phone No: Approved per applicable codes. Q Corrections required prior to approval. COMMENTS: (4) Inspector: Date: ( REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 8/1/2018 City of Tukwila Department of Community Development CONNIE HARDIN 4600 S 134 PL SEATTLE, WA 98168 RE: Permit No. M17-0164 BOEING #9-110 OFFICE TI 9725 E MARGINAL WAY S #9-110 Dear Permit Holder: Allan Ekberg, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permithas not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended o abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 9/17/2018. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your -permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 9/17/2018, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Rachelle Ripley Permit Technician File No: M17-0164 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0164 DATE: 11/07/17 PROJECT NAME: BOEING #9-110 SITE ADDRESS: 9725 E MARGINAL WAY S #9-110 X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued. DEPARTMENTS: AtUt Building Division Public Works R� av,,u 11 11 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 11/07/17 Structural Review Required REVIEWERQS INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/05/17 Approved ❑ Approved with Conditions ❑ Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERQS INITIALS: DATE: (Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 HOLADAY PARKS INC Hoene Espanol Contact Safety & Health Claims & Insurance Washington State Department of 40 Labor & Industries Page 1 of 3 Search L&I A -Z Index Help hMyL&I Workplace Rights Trades & Licensing HOLADAY PARKS INC Owner or tradesperson BECK, DAVID CARL Principals BECK, DAVID CARL, PRESIDENT CONNELL, DANIEL A, PRESIDENT GIRI, BIJIT, PRESIDENT PIZZEY, GRACE K, VICE PRESIDENT FREEL, JERRY LEE, VICE PRESIDENT PARKS, GERALD T JR, PRESIDENT (End: 08/12/2015) NAILON, JUNE ANNETTE, VICE PRESIDENT (End: 08/12/2015) O'CONNOR, BONNY K, SECRETARY (End: 08/12/2015) BECK, DAVID CLARENCE, TREASURER (End: 08/12/2015) VAN DER VEEN, ERIC M, VICE PRESIDENT (End: 08/14/2013) PIZZEY, GRACE KATHERINE, VICE PRESIDENT (End: 08/14/2013) VAN DER VEEN, JULIE ELIZABETH, MEMBER (End: 08/14/2013) CONNELL, DANIEL AARON, MEMBER (End: 08/14/2013) GIRI, BUIT, MEMBER (End: 08/14/2013) KIEL, RINALD HOWARD, MEMBER (End: 08/14/2013) WHITMYRE, CHRISTIAN, MEMBER (End: 08/14/2013) NELSON, MICHAEL, SECRETARY (End: 11/04/2010) PARKS, DAVID L, TREASURER (End: 11/04/2010) TALBOT, PAUL, TREASURER (End: 11/04/2010) WA UBI No. 578 004 089 4600 S 134TH PL SEATTLE, WA 98168 206-248-9700 KING County Business type Corporation License Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 11/21/2017 HOLADAY PARKS INC Verify the contractor's active registration / license Construction Contractor License specialties GENERAL License no. HOLADPI379NO Effective — expiration 0112111983— 09/03/2019 Bond LIBERTY MUTUAL INS CO Bond account no. 23000452 tification (depending on trade) and any past violations. Active. Meets current requirements. $12,000.00 Received by L&I Effective date 08/23/2002 09/01/2002 Expiration date Until Canceled Insurance Charter Oak Fire Ins Co Policy no. DTCO1F465357C0F17 $1,000,000.00 Received by L&I Effective date 10/31/2017 11/01/2017 Expiration date 11/01/2018 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees? If so, verify the business is up-to-date on workers' comp premiums. L&I Account ID 177,231-00 Account is current. Doing business as HOLADAY PARKS INC Estimated workers reported Quarter 3 of Year 2017 "Greater than 100 Workers" L&I account contact T4 / CASSANDRA SMITH (360)902-5632 - Email: SMCA235©Ini.wa.gov Public Works Strikes and Debarments Verify the contractor is eligible to perform work on public works projects. Contractor Strikes No strikes have been issued against this contractor. Contractors not allowed to bid No debarments have been issued against this contractor. Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Inspection results date 09/22/2016 Inspection no. No violations Page 2 of 3 Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=578004089&LIC=HOLADPI379N0&SAW= 11/21/2017 HOLADAY PARKS INC 317940948 Location 1007 Stewart St Seattle, WA 98101 Inspection results date 08/09/2016 Inspection no. 317940177 Location 1011 Western Ave, Suite 1000 Seattle, WA 98104 No violations Inspection results date 05/05/2016 Inspection no. 317940156 Location 4600 S 134th PI Tukwila, WA 98168 No violations Inspection results date 06/11/2014 Inspection no. 317319382 Location 1011 Dexter Ave Seattle, WA 98102 No violations Inspection results date 05/08/2014 Inspection no. 317278497 Location 2nd and 110th Ave Bellevue, WA 98004 No violations Inspection results date 09/04/2012 Inspection no. 316256841 Location 3003 W Casino Rd Everett, WA 98204 Violations Page 3 of 3 Washington State Dept. of Labor & Industries. Use of this site is subject to the laws of the state of Washington. Help us improve https://securelni.wa.gov/verify/Detail.aspx?UBI-578004089&LIC=HOLADPI379NO&SAW= 11/21/2017 \?44 SYM REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE:: Revisions will require a new plan submittal and may include additional plan review fees. FILEMM COPY PrmtNo. ' OI(aL- PIan review approval is subject to errors and omissions. Approval of construction documents doss not authorize the,. ; Y, of any adopted code or ordinance. Receipt of F' 0 c+nditions is knowledged: Date: 1,(: ZZ�.-7. City of Tukwila BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: Q Mechanical &Electrical 'Plumbing l'Gas Piping City of Tukwila BUILDING DIVISION_ VI C I \ ITY NAP PROJECT SITE FROM DOWNTOWN SEATTLE 0 900 (J) 99 EXIT 158 d EXIT 157 99 EAST MARGINAL WAY CORPORATE PARK FROM SEATTLE—TACOMA AIRPORT DEVELOP \IE\TAL C 599 TUKWILA \TES FROM KENT & AUBURN NO SCALE 900 REVISION BY APPROVED DATE SYM BOEING WORKPLACE SERVICES BUILDING 9-110 OFFICE TENANT IMPROVEMENT #34424 BOEING DEVELOPMENTAL CENTER 9725 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 A. EA NAP 3UILD1\G ADDESS: 9725 EAST NAKI\AL WAY SOUTH TU<WILA, WASHI\GTO\ PROJECT SITE 9-110 3UILDI G LOCATIO NO SCALE REVISION BY APPROVED DATE EXTRS: RELOCATE IR SIGN LAB (21-01) J#190105-02 RELOCATE 051 TO 9-110 J#120706-02 RELOCATE OS1 TO 9-110 (CONSTRUCTION) ADD GATES AND FENCE OFFICE TENANT IMPROVEMENT J#120706-02 J#545680-02 34224 GMM GMM GMM GMM SITTS 09.20.00 10.22.02 10.30.02 04.30.04 BKL 10.31.17 GE\RAL \ CTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE ON SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO JOHN MURDOCH AT BUILDING 09-051.2 COLUMN M/2, AFTER COMPLETION OF THIS CONSTRUCTION. SCOPE OF WO K INTERIOR TENANT IMPROVEMENT OF APPROXIMATELY 8,636 SF OF EXISTING OFFICE AREA. INCLUDES DEMOLITION OF NON—LOAD BEARING WALLS, RESTROOM RENOVATIONS, KITCHENETTE, AND REPLACEMENT OF FLOOR FINISHES, ACOUSTICAL CEILING TILES, AND PAINTING THROUGHOUT, WITH MINOR ELECTRICAL AND MECHANICAL MODIFICATIONS. THERE WILL BE NO CHANGES TO THE EXISTING BUILDING CONSTRUCTION TYPE OR OCCUPANCY GROUP CLASSIFICATION. THE OCCUPANT LOAD HAS BEEN INCREASED DUE TO THE ADDITION OF A CONFERENCE ROOM — REFER TO THE EXITING PLAN FOR THE EXITING SYSTEM. CODE SU V MAY LAND USE CODE BUILDING CODES TUKWILA 2015 I.B.C., U.F.C., U.P.C., AND THE WAC 51-20 AS ADAPTED OR AMENDED BY LOCAL ORDINANCES, AND COMPLIANCE WITH CITY OF TUKWILA ZONING. OCCUPANCY GROUP GROUP B (OFFICE) CONSTRUCTION TYPE FLOOR AREAS: BUILDING FOOTPRINT, GROSS AND FIRST FLOOR BUILDING HEIGHT STORIES OCCUPANT LOAD: HANDICAPPED REQUIREMENTS FIRE PROTECTION SEISMIC ZONE Q,�BOE/NG' TYPE VB SEPARATION 60 FEET (MINIMUM THREE SIDES) 8,636 S.F. 18 FT. 1 SEE 1A01 FOR EXITING PLAN ARCHITECT'S INTENT: FOR 2015 IBC WORK DESIGN WILL MAINTAIN EXISTING LIKE KIND MATERIALS AND ASSEMBLIES PER 97 UBC REQUIREMENTS. BARRIER FREE FULLY AUTOMATIC, F/S CLASS 1 SPRINKLERS THROUGHOUT 3 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DRAWN G.MILLER CHECKED DATE APPROVED APPROVED SUBTITLE TITLE DAWI\G I\DEX SHEET NO. DRAWING NO. SHEET TITLE REV NO. DATE GO 9-110—GO TITLE SHEET — 10.31.17 Al 9-110—A1 GENERAL ARCHITECTURAL NOTES AND CODE SUMMARY — 10.31.17 1A01 9-11.0-1A01 FIRST FLOOR EXITING PLAN C 10.31.17 1A1OR 9-110-1A1OR FLOOR PLAN — REMOVAL — 10.31.17 1A10 9-110-1A10 FLOOR PLAN F 10.31.17 1A280R 9-110-1A280R REFLECTED CEILING PLAN — REMOVAL — 10.31.17 1A280 9-110-1A280 REFLECTED CEILING PLAN — 10.31.17 1A450 9-110-1A450 ENLARGED FLOOR PLANS — 10.31.17 1A451 9-110-1A451 ENLARGED FLOOR PLANS — 10.31.17 A350 9-110_-A350 SCHEDULES — 10.31.17 A371 9-110—A371 INTERIOR ELEVATIONS — 10.31.17 A372 9-110—A372 INTERIOR ELEVATIONS — 10.31.17 A504 9-11.0—A504 MISC SECTIONS AND DETAILS — 10.31.17 A505 9-110—A505 MISC SECTIONS AND DETAILS — 10.31.17 A506 9-110—A506 MISC SECTIONS AND DETAILS — 10.31.17 A507 9-110—A507 MISC SECTIONS AND DETAILS — 10.31.17 M1R 9-11 0—M1 R SCHEDULES — REMOVAL B 10.31.17 1 M1 OR 9-110-1 M1 OR HVAC FIRST FLOOR PLAN — REMOVAL E 10.31.17 1 M11 OR 9-110-1 M11 OR PLUMBING PLAN — REMOVAL C 10.31.17 M450R 9-110—M450R PARTIAL PLAN — REMOVAL A 10.31.17 RFM 1 OR 9-110—RFM 1 OR HVAC ROOF PLAN — REMOVAL A 10.31.17 M1 9-110—M1 SCHEDULES B 10.31.17 1M10 9-11O-1 M10 HVAC FIRST FLOOR PLAN E 10.31.17 1M110 9-110-1M110 PLUMBING PLAN B 10.31.17 1M260 9-110-1M260 FIRE PROTECTION FIRST FLOOR PLAN D 10.31.17 M450 9-110—M450 PARTIAL PLAN A 10.31.17 RFM 10 9-110—RFM 10 HVAC ROOF PLAN A 10.31.17 E4R 9-110—E4R ONE LINE DIAGRAM — REMOVAL A 10.31.17 1 E1 OR 9-110-1 E1 OR LIGHTING FLOOR PLAN — REMOVAL E 10.31.17 1E6OR 9-110-1E6OR 120/208 VAC PLAN — REMOVAL M 10.31.17 1 E41 OR 9-110-1 E41 OR NETWORK PLAN — REMOVAL — 10.31.17 E4 9-110—E4 ONE LINE DIAGRAM A 10.31.17 1E10 9-110-1E10 LIGHTING FLOOR PLAN E 10.31.17 1E60 9-110-1 E60 120/208 VAC PLAN M 10.31.17 REVIEWED FOR 1E410 9-110-1E410 NETWORK PLAN CODE COMPLIANCE APPROVED — 10.31.17 E501 9-110—E501 MISCELLANEOUS DETAILS NOV 21 2017 A 10.31.17 E5XX 9-110—E5XX LIGHTING DETAILS • �� �` .— — 10.31.17 ,s• RECEIVED CITV OF TUKWILA NUV 0 6 2017 PERMIT CENTER TITLE SHEET BUILDING DIVISION! SIGN REVIEW OBER 31, 2017 OFFICE TENANT IMPROVEMENT ARCHITECTURAL MASTER BUILDING 9-110 SITTS & HILL ENGINEERS, INC. CIVIL • STRUCTURAL • SURVEYING 4815 CENTER STREET 1 TACOMA, WA. 98409 PHONE: (253) 474-9449 1 FAX: (253) 474-9449 http://www.sitts-hill-engineers.com/ Project No.: 18002 Project Mgr.: BKL Proj. Engineer: DCB Proj. Drafter: LAM CURRENT REVISION SYMBOL 34224 DATE 10.31.17 tio-wei5o SHEET GO JOB NO. COMP NO. DEV. CENTER, WA DWG No. 09-110—GO DUARTEE: -9/26/2013 6:17:46 AM SELF-CO\TA\ED GOOF TOP AlS CC\DTO\I\G U\J (ACU) SCHEDULE MARK N0. LOCATION NOMINAL CAPACITY TONS FAN FAN MOTOR COMPRESSOR EVAPORATOR COOLING CAPACITY CODENSER FAN/MOTOR ELECTRIC HEATER AIR FILTER REMARKS DRIVE TYPE CAPACITY (CFM) ESP IN WG HP VOLTS PHASE HERTZ NO VOLTS PHASE HERTZ FLA CAPACITY MBH(1) RM TEMP F N� DRIVE TYPE NOMINAL CFM HP VOLTS PHASE HERTZ RPM KW(2)VOLTS METALAIRE MODEL N0.410FV PHASE HERTZ FLA TYPE & DEPTH EFFICIENCY PER ASHRAE 52-76 MAX FINAL SP WG SENSIBLE TOTAL DB WB ACU -1 ROOF 30 BELT 8900 2.5 15 460 3 60 2 460 3 60 27.5 EA 196.7 269.7 75.0 61.5 3 DIRECT 21,000 1 460 3 60 1050 55 460 3 60 69 2" FARR 30/30 30% 0.9 SEE NOTE 3 30-290 35 6 275 0.2 1/6 277 1 60 2.0 277 1 60 METALAIRE MODEL NO.406FV FV -6 20-200 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -7 10-100 35 6 200 0.2 1/6 (1) MINIMUN (2) HEATING ELEMENTS SHIPPED SEPARATELY, 5 ELEMENTS TOTAL, INSTALL 3 ELEMENTS AND VERIFY THAT THE TOTAL RATING IS 50 KW MIN. - 55 KW MAX. THE REMAINING 2 ELEMENTS TO BE TURNED OVER TO BOEING. (3) PROVIDE ACU -1 CARRIER ROOF TOP VAV PACKAGED UNIT MODEL 50 DF034 WITH ROOF CURB. PROVIDE MICROPROCESSOR CONTROL PACKAGE INCLUDING; REMOTE PANEL MORNING WARMUP THERMOSTAT, 7 DAY PROGRAMMABLE TIME CLOCK, MODULATING OUTDOOR AIR CONTROL CONTROL PACKAGE, SAFETY CONTROLS, STATIC PRESSURE CONTROLS AND DAMPER ASSEMBLY AND HEAD PRESSURE CONTROL. VAALE MARK • TYPE AR VOLUE TEv\AL U\IT SCHEDULE MARK NUMBER AIR QUANTITY RANGE MIN. MAX. CFM MAX NC LEVEL @ 1.5" WG INLET INLET SIZE (INCH) HEATING AIR FLOW FAN MOTOR REMARKS CFM SP IN WG FAN MOTOR KW VOLTS PHASE HERTZ HP VOLTS PHASE HERTZ FV -1 100-920 35 10 830 0.3 1/6 277 1 60 4.5 277 1 60 METALAIRE MODEL N0.410FV FV -2 20-225 35 6 200 0.2 1/6 277 1 60 2.0 277 1 60 METALAIRE MODEL N0.406FV FV -4A 20-250 35 6 250 0.28 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -4B 20-250 35 6 250 0.28 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -5 30-290 35 6 275 0.2 1/6 277 1 60 2.0 277 1 60 METALAIRE MODEL NO.406FV FV -6 20-200 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -7 10-100 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -8 20-200 35 6 200 0.2 1/6 277 1 60 2.0 277 1 60 METALAIRE MODEL N0.406FV FV -9 15-150 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -10 15-150 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -11 15-150 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -12 20-215 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -13 40-470 35 8 550 0.22 1/6 277 1 60 3.0 277 1 60 METALAIRE MODEL N0.408FV FV -14 10-100 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL NO.406FV FV -15 20-275 35 6 250 0.28 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL NO.406FV FC -1 100-700 35 10 700 0.25 1/2 277 1 60 5.0 480 3 60 METALAIRE MODEL N0.410FC FC -2 100-700 35 10 700 0.25 1/2 277 1 60 5.0 480 3 60 METALAIRE MODEL N0.410FC FA -t NOT USED FA -2 0-800 35 8 - - - - - - - - - - ANEMOSTAT FA - SIZE 8 FA -3 0-820 35 10 - - - - - - - - - - ANEMOSTAT FA - SIZE 10 FA -4 0-120 35 5 - - - - - - - - - - ANEMOSTAT FA - SIZE 5 FA -5 0-355 35 6 - - - - . - - - - - - ANEMOSTAT FA -SIZE .6 FA -6 0-533 35 8 - - - - - - - - - - ANEMOSTAT FA - SIZE 8 FA -7 0-480 35 8 - - - - - - - - - - ANEMOSTAT FA - SIZE 8 FA -8 0-240 35 6 - - - - - - - - - - ANEMOSTAT FA - SIZE 6 FA -9 0-240 35 6 - - - - - - - - - - ANEMOSTAT FA - SIZE 6 (1) PROVIDE DISCONNECT SWITCH AND NAGNETIC CONTACT (2) FV -3 NOT USED AIR DIFFSER/REGISTER/GILLE SC-iDLE MARK • TYPE MATERIAL FINISH INLET/NECK SIZE N - S MAXIMUM , REMARKS ry/ 40' 'i - f i 1 0.10 360 INDUSTRIAL ACOUSTIC CO. QUIET VENT SILENCER, TYPE W, MODEL 430 INSTALL W/GRILLES AND PAINT OFF-WHITE ,„ • ,.,,,,,e , t 5-75e,,, VOLTS 7 HERTZ 2,,,,,,,,,e/i7 VESTIBULE 200 vty17// I6W/ 277 1 60 1/60 1100 277 - 4 : , : \. MOUNTED END TO END TO APPEAR CONTINUOUS. SD -1 SUPPLY DIFFUSER ALUMINUM WHITE 12"x6" SEE PLAN T I TUS MODEL #SERIES S-202FD RG -1 RETURN GRILLE ALUMINUM WHITE 12"x24" SEE PLAN T I TUS MODEL #50 -MLR RG -2 RETURN GRILLE ALUMINUM WHITE 24"x24" SEE PLAN T I TUS MODEL #50 -MLR RR -1 RETURN REGISTER ALUMINUM WHITE 24"x24" SEE PLAN T I TUS MODEL #4-FLOG5 WITH FILTER AND DAMPER - - - 2 277 1 60 .45 5 1" FARR 30/30 30% - SEE NOTE 1 SO\D ATTi\ATOR SA SC-EDLE MARK No . SERVICE LENGTH FEET MAXIMUM PD IN/H2O AIR QUANTITY CFM REMARKS SA -1 CONFERENCE ROOM 5'-6" 0.10 360 INDUSTRIAL ACOUSTIC CO. QUIET VENT SILENCER, TYPE W, MODEL 430 INSTALL W/GRILLES AND PAINT OFF-WHITE RPM VOLTS PHASE HERTZ CBH-1 VESTIBULE FOCE AlS CATh\ET -EATEN SCHEDULE MARK NUMBER LOCATION CFM ELECTRIC HEATER FAN MOTOR REMARKS KW VOLT PHASE HERTZ HP RPM VOLTS PHASE HERTZ CBH-1 VESTIBULE 200 3.75 277 1 60 1/60 1100 277 1 60 SEE NOTE #1 NOTE 1: HORIZONTAL CEILING SURFACE NOUNTED FORCED AIR CABINET. HEATER TRANE MODEL D46 SIZE 02 PROVIDE DISCONNECT .SWITCH, SINGLE HEAT SWITCH AND MOTOR SWITCH H-173 WITH UNIT MOUNTED THERMOSTAT AND PROVIDE FILTER. FORCED AlS U\IT HEATED SCHEDULE MARK NUMBER LOCATION CFM HEATER FAN MOTOR REMARKS HP VOLTS PHASE HERTZ UH -1 GARAGE 400 75K BTU GAS UNIT HEATER 1/3 115 1 60 DATON #3E227 UNIT HEATER HP COVDLTER ROOV COOL \G \IT SC-EDLE MARK No. LOCATION TYPE NOMINAL CAPACITY TONS FAN FAN MOTOR COOLING COIL CAPACITY CHILLED WATER HUMIDIFIER ELECTRIC REHEAT COIL KW AIR FILTER REMARKS DRIVE TYPE CAPACITY CFM) ESP IN W.G. HP VOLTS PHASE HERTZ CAPACITY MBH RM TEMP F GPM EWT F MAX PD @ MAPSFLOW I#�HR app, VOLT PHASE HERTZ KW TYPE & DEPTH EFFICIENCY PER ASHRAE 52-76 MAX INITIAL SP WG SENSIBLE TOTAL DB WBFLQN CRU -1 &CRU -2 COMPUTER ROOM CEILING MOUNTED 2 DIRECT 800 - 2/3 277 1 60 19.9 25.1 80 67 - - - - 2 277 1 60 .45 5 1" FARR 30/30 30% - SEE NOTE 1 NOTE 1: HILANDER AIR COOLED MODEL NO. CB06A WITH ELECTRIC REHEAT, HUMIDIFIER, 1/2" REMOTE BLOWER UNIT. REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE JR SIGNATURE LAB J#190105-02 CH/KB 9.20.00 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 Q� ffOE/NG° C'- REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K.BUN DATE CHECKED C.HARRAH SUBTITLE 90% SUBMITTAL OCTOBER 31, 2017 SCHEDULES RECEIVED CITY OF TUKWILA G` lid 0 6 2017 PERMIT CENTER CURRENT REVISION 34224 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION SYMBOL FSi consulting engineers Seattle, Washington Solutions (Sc Service 3 DATE 10.31.17 ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER 9-110 DENSIFICATION BUILDING 9-110.1 N/A SHEET M1R JOB NO. COMP NO. DWG N0. D.C. 9-110-M1R SYM -r if/111111011111.1 Mail ©i s '� 1 ��P 1g ■It I Alit MI�#>I ►>. 1111111111111E° m>..©IA V III �11 250 270 TOP OF GRILLE CFM IN CQNFERENCE Room IS 7'-0" AFF BOTT M OFRILLE IN 0 EN OFF CE AR IS 1'- " AFF REVISION BY APPROVED A iM10 M500 DATE SYM REVISION BY APPROVED DATE A IR SIGNATURE LAB J#190105-02 CH/KB 9.20.00 B IR SIGNATURE LAB (CODE REVISION) J#190105-02 CH 10-31-00 C INSTALL CEILING DIFFUSER J#120706-02 DMV RWS 10.30.02 D RELOCATE BR&T STORAGE J#20368-10 EISI MW 12.15.13 E 9-110 DENSIFICATION 34224 FSi, AWL 10.31.17 Q� BOE/NGS r> - 1M10 4002— vl7 30x18, 30x24 HI & LOW LOUVER (2 PLACES) REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY 10.31.17 PRIM, DATE DRAWN K.BUN DATE 9.20.00 CHECKED C.HARRAH ENGINEER CHECKED APPROVED 9.20.00 SUBTITLE RECEIVED CITY OF TUKWIL A NOV 0 6 2017 PERMIT CENTER 90% SUBMITTAL OCTOBER 31, 2017 HVAC FIRST FLOOR PLAN LEGE\J 20/12 20/1 2 200 RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST ROUND DUCT, NUMBER INDICATES 200 DIAMETER EQ 0 C iP LINED DUCT FLEXIBLE DUCT LINEAR DIFFUSER AND CFM AIR FLOW RETURN/RELIEF GRILLE, CEILING TYPE UNIT HEATER, HORIZONTAL THERMOSTAT VE\T \OTES EXHAUST FAN MANUFACTURER: NEW YORK BLOWER MODEL: COMPACT GI SIZE: 95 ARRANGEMENT: 4 - DIRECT DRIVE DISCHARGE: TOP HORIZONTAL WHEEL MATERIAL: ALUMINUM MOTOR: 1/2 HP 120V, 60 CYCLE, SINGLE PHASE PERFORMANCE: 150 CFM AT 1.15" STATIC PRESSURE SPEED: 1740 RPM, POWER: 0.163 HP FAN AND DAMPERS TO BE INTERLOCKED WITH THE BATTERY CHARGING EQUIPMENT. GE\EAL OYES 2. RETURN AIR DUCT TO BE INSTALLED AS HIGH AS POSSIBLE WITH TOP OF DUCT HEIGHT TO BOTTOM ON ROOF STRUCTURE. SUPPLY AIR DUCTS TO BE INSTALLED BENEATH RETURN AIR DUCTS. CARE SHOULD BE TAKEN TO AVOID EXISTING SPRINKLER SYSTEM. 3. ALL RETURN AIR DUCTS ARE ACOUSTICALLY LINED, AND ALL SUPPLY AIR DUCTS FROM THE OUTLET OF AHU-1 TO THE TERMINAL BOXES ARE ACOUSTICALLY LINED. SEE SPECIFICATIONS SHEET M2. 4. DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 5. THE SIZE OF DUCTS TO INDIVIDUAL DIFFUSERS SHALL BE THE SAME SIZE AS THE INLET/NECK SIZE INDICATED ON THE SCHEDULE SHEET M3 UNLESS OTHERWISE NOTED. 6. FOR DETAIL OF TRANSFER AIR DUCTS. SEE DETAIL M-4 M-6 7. RIGID DUCTS DOWNSTREAM OF VAV TERMINAL BOXES TO BE SAME SIZE AS VAV TERMINAL BOX OUTLET UNLESS OTHERWISE NOTED. MINIMUM HEIGHT OF RIGID DUCTS DOWNSTREAM OF FA -X BOXES TO BE 10". 8. ALL LINEAR SLOT DIFFUSER TO BE TYPE LD -1 UNLESS OTHERWISE NOTED. 9. ALL RETURN AIR GRILLES TO BE TYPE RG -1 UNLESS OTHERWISE NOTED. 10. THIS MECHANICAL PLAN WAS COMPLETED PRIOR TO THE COMPLETION OF DRAWING E10, LIGHTING PLAN. THE RELOCATION OF RETURN GRILLES 2'-0" IN ANY DIRECTION TO AVOID INTERFERENCES WITH LIGHTING IS PERMISSIBLE. 11. THE TWO EXISTING 12/12 PENETRATIONS IN THE TOP OF THE CONFERENCE ROOM (PREVIOUSLY THE VAULT) •ARE TO BE USED FOR NEW DISTRIBUTION DUCTWORK. 12. RELOCATE GAS WATER HEATER AND TIE-IN GAS, COLD WATER, AND HOT WATER PIPING AND VENT INTO EXISTING SERVICES. EVOVAL \OTES REMOVE DIFFUSERS AND GRILLE. PROTECT DUCT FOR RECONNECTION. REMOVE GRILLE. PROTECT DUCT FOR RECONNECTION. REMOVE DIFFUSERS, TERMINAL UNITS AND DUCT BACK TO 12x12 MAIN. PROTECT TERMINAL UNIT FOR RECONNECTION. REMOVE DIFFUSERS AND DUCT TO TRUNK AND CAP. REMOVE AC UNIT, SUPPORTS AND ASSOCIATED PIPING. > REMOVE DUCT. TERMINAL UNIT AND DIFFUSER TO REMAIN. REMOVE EXHAUST GRILLES AND DUCTWORK UP TO EXHAUST FAN. REMOVE RETURN GRILLES NOT CONNECTED TO TERMINAL UNITS. LINEAR DIFFUSER TO BE CLEANED AND TO REMAIN. REMOVE RETURN GRILLE MOUNTED THERMOSTATS. MOUNT ON NEAREST INTERIOR COLUMN OR WALL ABOVE CUBICLE HEIGHT. 1 11. ALL SQUARE GRILLES AND DIFFUSERS TO BE REPLACED. LINEAR DIFFUSERS TO BE REMOVED AND REPLACED WITH SQUARE DIFFUSERS, WITH EXCEPTION OF LINEAR DIFFUSERS BEING SPECIFICALLY CALLED TO REMAIN, SEE CONSTRUCTION NOTE 9. REVIEWED FOR CODE COMPLIANCE) APPROVED 4 8 16 24 .1 NI OMNI MI NOV 21 2011 S City of Tukwila BUILDING DIVISION ALE: 1/8"=1'-0" FSi consulting engineers Seattle, Washington CURRENT REVISION 34224 Solutions (Sc Service SYMBOL E DATE 10.31.17 TITLE MECHANICAL MASTER 9-110 DENSIFICATION BUILDING 9-110 COL. A—DD / 1-4L SHEET IMIOR JOB NO. J#190105-02 COMP NO. DWG NO. D.C. 9-110-1M1OR SYM REVISION ENTRANCE CANOPY jam;x--- ; -- '-. ON ROOF FRIEDRICH MODEL #MR24C3S COMPRESSOR RLA-10.0, LRA 61.0 BY APPROVED DATE SYM REVISION FIST FLOO PLA\ SCALE: 1/8"=1 —0" BY APPROVED DATE A 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 BOENG' C�- REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DRAWN K.BUN DATE SUBTITLE GE\RAL \OTES EvOVAL \OTES REMOVE CONDENSING UNIT, SUPPORTS, AND PIPING. REMOVE EXHAUST FAN AND CURB. RECEIVED CITY OF TUKWILA 90% SUBMITTAL OCTOBER 31, 2017 HVAC ROOF PLAN CURRENT REVISION 34224 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 City of Tukwila BUILDING DIVISION FSi consulting engineers Seattle, Washington Solutions & Service SYMBOL A DATE 10.31.17 ENGINEER TITLE 9-110 DENSIFICATION BUILDING 9-110.1 10.31.17 gmwrik APPROVED MECHANICAL MASTER COL. ALL D. DWG NO. COMP NO. 9-110—RFM1OR SYM SELF-CO\TAI\ED GOOF TOP Aid CO\DITIO\I\G U\IT (ACU) SCHEDLE MARK N0. LOCATION NOMINAL CAPACITY TONS FAN FAN MOTOR COMPRESSOR EVAPORATOR COOLING CAPACITY CODENSER FAN/MOTOR ELECTRIC HEATER AIR FILTER REMARKS DRIVE TYPE CAPACITY (CFM) ESP IN WG HP VOLTS PHASE HERTZ NO VOLTS PHASE HERTZ FLA CAPACITY MBH(i) RM TEMP F NO. DRIVE TYPE NOMINAL CFM HP VOLTS PHASE HERTZ RPM KW (2) VOLTS PHASE HERTZ FLA TYPE & DEPTH EFFICIENCY PER ASHRAE 52-76 MAX FINAL SP WG SENSIBLE TOTAL DB WB ACU -1 ROOF 30 BELT 8900 2.5 15 460 3 60 2 460 3 60 27.5 EA 196.7 269.7 75.0 61.5 3 DIRECT 21,000 1 460 3 60 1050 55 460 3 60 69 2" FARR 30/30 30% 0.9 SEE NOTE 3 6 275 0.2 1/6 277 1 60 2.0 277 1 60 METALAIRE MODEL NO.406FV FV -6 20-200 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL NO.406FV FV -7 10-100 35 6 200 0.2 1/6 277 1 (1) MINIMUN (2) HEATING ELEMENTS SHIPPED SEPARATELY, 5 ELEMENTS TOTAL, INSTALL 3 ELEMENTS AND VERIFY THAT THE TOTAL RATING IS 50 KW MIN. - 55 KW MAX. THE REMAINING 2 ELEMENTS TO BE TURNED OVER TO BOEING. (3) PROVIDE ACU -1 CARRIER ROOF TOP VAV PACKAGED UNIT MODEL 50 DF034 WITH ROOF CURB. PROVIDE MICROPROCESSOR CONTROL PACKAGE INCLUDING; REMOTE PANEL MORNING WARMUP THERMOSTAT, 7 DAY PROGRAMMABLE TIME CLOCK, MODULATING OUTDOOR AIR CONTROL CONTROL PACKAGE, SAFETY CONTROLS, STATIC PRESSURE CONTROLS AND DAMPER ASSEMBLY AND HEAD PRESSURE CONTROL. VAIA3LE AIR VOLNE TEvi\AL U\IT SCHEULE MARK NUMBER AIR QUANTITY RANGE MIN. MAX. CFM MAX ,SNC LEVEL @ 1.5 WG INLET INLET SIZE (INCH) HEATING AIR FLOW FAN MOTOR REMARKS CFM SP IN WG FAN MOTOR KW VOLTS PHASE HERTZ HP VOLTS PHASE HERTZ FV -1 100-920 35 10 830 0.3 1/6 277 1 60 4.5 277 1 60 METALAIRE MODEL N0.410FV FV -2 20-225 35 6 200 0.2 1/6 277 1 60 2.0 277 1 60 METALAIRE MODEL N0.406FV FV -4A 20-250 35 6 250 0.28 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL NO.406FV FV -4B 20-250 35 6 250 0.28 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL NO.406FV FV -5 30-290 35 6 275 0.2 1/6 277 1 60 2.0 277 1 60 METALAIRE MODEL NO.406FV FV -6 20-200 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL NO.406FV FV -7 10-100 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -8 20-200 35 6 200 0.2 1/6 277 1 60 2.0 277 1 60 METALAIRE MODEL N0.406FV FV -9 15-150 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL NO.406FV FV -10 15-150 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL NO.406FV FV -11 15-150 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -12 20-215 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -13 40-470 35 8 550 0.22 1/6 277 1 60 3.0 277 1 60 METALAIRE MODEL NO.408FV FV -14 10-100 35 6 200 0.2 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FV -15 20-275 35 6 250 0.28 1/6 277 1 60 1.0 277 1 60 METALAIRE MODEL N0.406FV FC -1 100-700 35 10 700 0.25 1/2 277 1 60 5.0 480 3 60 METALAIRE MODEL NO.410FC FC -2 100-700 35 10 700 0.25 1/2 277 1 60 5.0 480 3 60 METALAIRE MODEL NO.410FC FA -1 NOT USED FA -2 0-800 35 8 - - - - - - - - - - ANEMOSTAT FA - SIZE 8 FA -3 0-820 35 10 - - - - - - - - - - ANEMOSTAT FA - SIZE 10 FA -4 0-120 35 5 - - - - - - - - - - ANEMOSTAT FA - SIZE 5 FA -5 0-355 35 6 - - - - - - - - - - ANEMOSTAT. FA -. SIZE 6 FA -6 0-533 35 8 - - - - - - - - - - ANEMOSTAT FA - SIZE 8 FA -7 0-480 35 8 - - - - - - - - - - ANEMOSTAT FA - SIZE 8 FA -8 0-240 35 6 - - - - - - - - - - ANEMOSTAT FA - SIZE 6 FA -9 0-240 35 6 - - - - - - - - - - ANEMOSTAT FA - SIZE 6 (1) PROVIDE DISCONNECT SWITCH AND NAGNETIC CONTACT (2) FV -3 NOT USED AIR DFPSI/EC SA STE/CR LL- SC-iDLE MARK No. TYPE MATERIAL FINISH INLET/NECK SIZE INCHES MAXIMUM SET CFM REMARKS LD -3 ADJ. LINEAR DIF. ALUMINUM WHITE 4" x LENGTH SEE PLAN CARNES CHANNEL-AIRE #487335, 3-1/2" SLOT, 10 5' LONG SECTIONS MOUNTED END TO END TO APPEAR CONTINUOUS. ,_ _�• 277 1 ” ,,, 9_,, T S „$D it S- 1 II 1 SD -2 SUPPLY DIFFUSER ALUMINUM WHITE 6"x6" 150 T I TUS 4 -WAY MCD SD -1 SUPPLY DIFFUSER ALUMINUM WHITE 8"x8" 300 T I TUS 4 -WAY MCD -1 "1 - L A 1 '"'IT 2'x 4" S 'r i Y.1 # ,- - RG -2 RETURN GRILLE ALUMINUM WHITE 24"x24" SEE PLAN T I TUS MODEL #50 -MLR RR -1 RETURN REGISTER ALUMINUM WHITE 24"x24" SEE PLAN T I TUS MODEL #4-FLOG5 WITH FILTER AND DAMPER - - - 2 277 1 60 .45 5 1" FARR 30/30 30% - SEE NOTE 1 SO\D ATTi\ATO SA SC-EDLE MARK No . SERVICE LENGTH FEET MAXIMUM PD IN/H20 AIR QUANTITY CFM REMARKS SA -1 CONFERENCE ROOM 5'-6" 0.10 360 INDUSTRIAL ACOUSTIC CO. QUIET VENT SILENCER, TYPE W, MODEL 430 INSTALL W/GRILLES AND PAINT OFF-WHITE HERTZ CBH-1 VESTIBULE 200 3.75 277 FORCED AIS CA31\ET HEATED SCHEDULE MARK NUMBER LOCATION CFM ELECTRIC HEATER FAN MOTOR REMARKS KW VOLT PHASE HERTZ HP RPM VOLTS PHASE HERTZ CBH-1 VESTIBULE 200 3.75 277 1 60 1/60 1100 277 1 60 SEE NOTE #1 NOTE 1: HORIZONTAL CEILING SURFACE NOUNTED FORCED. AIR. CABINET HEATER TRANE MODEL D46 SIZE 02 PROVIDE DISCONNECT SWITCH, SINGLE HEAT SWITCH AND MOTOR SWITCH H-173 WITH UNIT MOUNTED THERMOSTAT AND PROVIDE FILTER. FOCED AlS U\IT -EATEN SC-EDULE MARK NUMBER LOCATION CFM HEATER FAN MOTOR REMARKS HP VOLTS PHASE HERTZ UH -1 GARAGE 400 75K BTU GAS UNIT HEATER 1/3 115 1 60 DATON #3E227 UNIT HEATER REMARKS Cnt\/3 CALLOUT TI FAN TYPE OOv COOL \G BASIS OF DESIGN \IT SC -EI/E MARK No. LOCATION TYPE NOMINAL CAPACITY TONS FAN FAN MOTOR COOLING COIL CAPACITY CHILLED WATER HUMIDIFIER ELECTRIC REHEAT COIL KW AIR FILTER REMARKS DRIVE TYPE CAPACITY (CFM) ESP IN W.G. HP VOLTS PHASE HERTZ CAPACITY MBH RM TEMP F FLOW GPM EW7 F MAX PD @ MAX FLOW PSI CAP. #/HR VOLT PHASE HERTZ KW TYPE & DEPTH EFFICIENCY PER ASHRAE 52-76 MAX INITIAL SP WG SENSIBLE TOTAL DB WB CRU -1 & CRU -2 COMPUTER ROOM CEILING MOUNTED 2 DIRECT 800 - 2/3 277 1 60 19.9 25.1 80 67 - - - - 2 277 1 60 .45 5 1" FARR 30/30 30% - SEE NOTE 1 NOTE 1: HILANDER AIR COOLED MODEL NO. CB06A WITH ELECTRIC REHEAT, HUMIDIFIER, 1/2" REMOTE BLOWER UNIT. EXHAUST FA\ SC-EDULE CALLOUT LOCATION FAN TYPE SERVICE FAN MAX SOUND LEVEL BASIS OF DESIGN NOTES TYPE MARK CFM DRIVE TYPE STATIC PRESSURE (IN WC) [1] TIP SPEED (FPM) RPM MOTOR MANUFACTURER MODEL RPM HP W EF 1 ROOF DOWNBLAST RESTROOMS/JANITOR 350 DIRECT 0.50 3670 1550 1550 0.125 131 55 COOK ACE -D SCHEDULE NOTES: [1] STATIC PRESSURE EXTERNAL TO FAN. REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A JR SIGNATURE LAB 4190105-02 CH/KB 9.20.00 B 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 el_m.Ear,,Nre0 10.31.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN K.BUN DATE CHECKED C.HARRAH ENGINEER CHECKED APPROVED APPROVED SUBTITLE 90% SUBMITTAL OCTOBER 31, 2017 SCHEDULES RECEIVED CITY OF TUK'VILA REVIEWED FOR CODE COMPLIANCE NUV 0 6 2017 APPROVED PERMIT CENTEF9 NOV 21 2017 CURRENT REVISION SYMBOL 34224 City orf Tukwila BUILDING DIVISION FSi consulting engineers Seattle, Washington Solutions & Service 3 DATE 10.31.17 TITLE 9-110 DENSIFICATION BUILDING 9-110.1 MECHANICAL MASTER N/A SHEET M1 JOB NO. COMP NO. DWG N0. D.C. 9-110-M1 310 CFM (TYP 31 108/16 RA 1� 1M10 M500 An 80 ®CFM 270 CFM TOP OF GRILLE IN C NFERENCE R00 IS 7'-0" AFF BO M OF RILLE IN 0 EN OFF CE AR IS 1'- " AFF 300 0 A iM10 M500 0 00 CFM 80 FM o 280 CFM 150 \CFM I►� 220 150 CFM E -1 150 CFM 240 CFM P TO ROOF A 1M1 -002- M7 FIST FL0CH PLA\ SCALE: 1/8"=1 —0" 30x18, 30x24 HI & LOW LOUVER (2 PLACES) 90% SUBMITTAL OCTOBER 31, 2017 LECE\J 20/12 20/12 DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN 200 200 EQUIP ROUND DUCT, NUMBER INDICATES DIAMETER LINED DUCT FLEXIBLE DUCT LINEAR DIFFUSER AND CFM AIR FLOW RETURN/RELIEF GRILLE, CEILING TYPE UNIT HEATER, HORIZONTAL THERMOSTAT VE\T \OTES EXHAUST FAN MANUFACTURER: NEW YORK BLOWER MODEL: COMPACT GI SIZE: 95 ARRANGEMENT: 4 - DIRECT DRIVE DISCHARGE: TOP HORIZONTAL WHEEL MATERIAL: ALUMINUM MOTOR: 1/2 HP 120V, 60 CYCLE, SINGLE PHASE PERFORMANCE: 150 CFM AT 1.15" STATIC PRESSURE SPEED: 1740 RPM, POWER: 0.163 HP FAN AND DAMPERS TO BE INTERLOCKED WITH THE BATTERY CHARGING EQUIPMENT. GE\E�AL \OTES 2. RETURN AIR DUCT TO BE INSTALLED AS HIGH AS POSSIBLE WITH TOP OF DUCT HEIGHT TO BOTTOM ON ROOF STRUCTURE. SUPPLY AIR DUCTS TO BE INSTALLED BENEATH RETURN AIR DUCTS. CARE SHOULD BE TAKEN TO AVOID EXISTING SPRINKLER SYSTEM. 3. ALL RETURN AIR DUCTS ARE ACOUSTICALLY LINED, AND ALL SUPPLY AIR DUCTS FROM THE OUTLET OF AHU-1 TO THE TERMINAL BOXES ARE ACOUSTICALLY LINED. SEE SPECIFICATIONS SHEET M2. 4. DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 5. THE SIZE OF DUCTS TO INDIVIDUAL DIFFUSERS SHALL BE THE SAME SIZE AS THE INLET/NECK SIZE INDICATED ON THE SCHEDULE SHEET M3 UNLESS OTHERWISE NOTED. 6. FOR DETAIL OF TRANSFER AIR DUCTS. SEE DETAIL M-4 M-6 7. RIGID DUCTS DOWNSTREAM OF VAV TERMINAL BOXES TO BE SAME SIZE AS VAV TERMINAL BOX OUTLET UNLESS OTHERWISE NOTED. MINIMUM HEIGHT OF RIGID DUCTS DOWNSTREAM OF FA -X BOXES TO BE 10". 8. ALL LINEAR SLOT DIFFUSER TO BE TYPE LD -1 UNLESS OTHERWISE NOTED. 9. ALL RETURN AIR GRILLES TO BE TYPE RG -1 UNLESS OTHERWISE NOTED. 10. THIS MECHANICAL PLAN WAS COMPLETED PRIOR TO THE COMPLETION OF DRAWING E10, LIGHTING PLAN. THE RELOCATION OF RETURN GRILLES 2'-0" IN ANY DIRECTION TO AVOID INTERFERENCES WITH LIGHTING IS PERMISSIBLE. 11. THE TWO EXISTING 12/12 PENETRATIONS IN THE TOP OF THE CONFERENCE ROOM (PREVIOUSLY THE VAULT) ARE TO BE USED FOR NEW DISTRIBUTION DUCTWORK. 12. RELOCATE GAS WATER HEATER AND TIE-IN GAS, COLD WATER, AND HOT WATER PIPING AND VENT INTO EXISTING SERVICES. C3\S-RUCTIO\ \OTES MOUNT T -STAT ON NEAREST WALL/COLUMN ABOVE CUBICLE HEIGHT. INSTALL DIFFUSERS/GRILLES AND ASSOCIATED DUCTWORK TO MATCH DROP CEILING LAYOUT. 3. CONNECT ALL VAV BOXES AND AHU TO SITEWIDE SIEMENS CMS SYSTEM. PROVIDE RETURN GRILLE. MATCH EXISTING. PROVIDE RETURN AIR FILTERS ON 4 MAIN RETURN DUETS. 6. VERIFY FUNCTION AND PROPER OPERATION OF ALL VAV HEATERS, FANS AND DAMPERS. REPLACE OR REPAIR AS NEEDED. ROUTE DUCT TO EXHAUST FAN. RELOCATE FV -8 FROM SE CONFERENCE ROOM. RELOCATE TERMINAL BOX AND ASSOCIATED SUPPORTS FOR NEW ROOM CONFIGURATION. R CEIVEC CITY OF TUK tUV p6 2 pE,BAIILT CE 1lLREVIEVVED FOR 4 8 CODE COMPLIAimm o { 7 APPROVED sCAA ERNOV 21 2017 City of Tukwila BUILDING DIVISIO 1/8"= 16 24 • FSi consulting engineers Seattle, Washington Solutions & Service SYM A REVISION IR SIGNATURE LAB B IR SIGNATURE LAB (CODE REVISION) J#190105-02 J#190105-02 BY CH/KB APPROVED DATE SYM REVISION BY APPROVED DATE 9.20.00 CH 10-31-00 C INSTALL CEILING DIFFUSER J#120706-02 DMV RWS 10.30.02 D RELOCATE BR&T STORAGE J#20368-10 EISI MW 12.15.13 E 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 Q� BOE/NG° C' - 10.31.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K.BUN DATE 9.20.00 APPROVED BY DEPT. DATE CHECKED C. HARRAH ENGINEER 9.20.00 SUBTITLE HVAC FIRST FLOOR PLAN CURRENT REVISION 34224 SYMBOL E DATE 10.31.17 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTFR 9-110 DENSIFICATION BUILDING 9-110 COL. A—DD / 1-4L D.C. SHEET 1 M 1 0 JOB NO. J#190105-02 COMP NO. DWG NO. 9-110-1M10 100 CFM 150 \CFM I►� 220 150 CFM E -1 150 CFM 240 CFM P TO ROOF A 1M1 -002- M7 FIST FL0CH PLA\ SCALE: 1/8"=1 —0" 30x18, 30x24 HI & LOW LOUVER (2 PLACES) 90% SUBMITTAL OCTOBER 31, 2017 LECE\J 20/12 20/12 DUCT SHOWN IN SECTION, ARROW POINTS TO SIDE CALLED OUT FIRST RECTANGULAR DUCT, FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN 200 200 EQUIP ROUND DUCT, NUMBER INDICATES DIAMETER LINED DUCT FLEXIBLE DUCT LINEAR DIFFUSER AND CFM AIR FLOW RETURN/RELIEF GRILLE, CEILING TYPE UNIT HEATER, HORIZONTAL THERMOSTAT VE\T \OTES EXHAUST FAN MANUFACTURER: NEW YORK BLOWER MODEL: COMPACT GI SIZE: 95 ARRANGEMENT: 4 - DIRECT DRIVE DISCHARGE: TOP HORIZONTAL WHEEL MATERIAL: ALUMINUM MOTOR: 1/2 HP 120V, 60 CYCLE, SINGLE PHASE PERFORMANCE: 150 CFM AT 1.15" STATIC PRESSURE SPEED: 1740 RPM, POWER: 0.163 HP FAN AND DAMPERS TO BE INTERLOCKED WITH THE BATTERY CHARGING EQUIPMENT. GE\E�AL \OTES 2. RETURN AIR DUCT TO BE INSTALLED AS HIGH AS POSSIBLE WITH TOP OF DUCT HEIGHT TO BOTTOM ON ROOF STRUCTURE. SUPPLY AIR DUCTS TO BE INSTALLED BENEATH RETURN AIR DUCTS. CARE SHOULD BE TAKEN TO AVOID EXISTING SPRINKLER SYSTEM. 3. ALL RETURN AIR DUCTS ARE ACOUSTICALLY LINED, AND ALL SUPPLY AIR DUCTS FROM THE OUTLET OF AHU-1 TO THE TERMINAL BOXES ARE ACOUSTICALLY LINED. SEE SPECIFICATIONS SHEET M2. 4. DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 5. THE SIZE OF DUCTS TO INDIVIDUAL DIFFUSERS SHALL BE THE SAME SIZE AS THE INLET/NECK SIZE INDICATED ON THE SCHEDULE SHEET M3 UNLESS OTHERWISE NOTED. 6. FOR DETAIL OF TRANSFER AIR DUCTS. SEE DETAIL M-4 M-6 7. RIGID DUCTS DOWNSTREAM OF VAV TERMINAL BOXES TO BE SAME SIZE AS VAV TERMINAL BOX OUTLET UNLESS OTHERWISE NOTED. MINIMUM HEIGHT OF RIGID DUCTS DOWNSTREAM OF FA -X BOXES TO BE 10". 8. ALL LINEAR SLOT DIFFUSER TO BE TYPE LD -1 UNLESS OTHERWISE NOTED. 9. ALL RETURN AIR GRILLES TO BE TYPE RG -1 UNLESS OTHERWISE NOTED. 10. THIS MECHANICAL PLAN WAS COMPLETED PRIOR TO THE COMPLETION OF DRAWING E10, LIGHTING PLAN. THE RELOCATION OF RETURN GRILLES 2'-0" IN ANY DIRECTION TO AVOID INTERFERENCES WITH LIGHTING IS PERMISSIBLE. 11. THE TWO EXISTING 12/12 PENETRATIONS IN THE TOP OF THE CONFERENCE ROOM (PREVIOUSLY THE VAULT) ARE TO BE USED FOR NEW DISTRIBUTION DUCTWORK. 12. RELOCATE GAS WATER HEATER AND TIE-IN GAS, COLD WATER, AND HOT WATER PIPING AND VENT INTO EXISTING SERVICES. C3\S-RUCTIO\ \OTES MOUNT T -STAT ON NEAREST WALL/COLUMN ABOVE CUBICLE HEIGHT. INSTALL DIFFUSERS/GRILLES AND ASSOCIATED DUCTWORK TO MATCH DROP CEILING LAYOUT. 3. CONNECT ALL VAV BOXES AND AHU TO SITEWIDE SIEMENS CMS SYSTEM. PROVIDE RETURN GRILLE. MATCH EXISTING. PROVIDE RETURN AIR FILTERS ON 4 MAIN RETURN DUETS. 6. VERIFY FUNCTION AND PROPER OPERATION OF ALL VAV HEATERS, FANS AND DAMPERS. REPLACE OR REPAIR AS NEEDED. ROUTE DUCT TO EXHAUST FAN. RELOCATE FV -8 FROM SE CONFERENCE ROOM. RELOCATE TERMINAL BOX AND ASSOCIATED SUPPORTS FOR NEW ROOM CONFIGURATION. R CEIVEC CITY OF TUK tUV p6 2 pE,BAIILT CE 1lLREVIEVVED FOR 4 8 CODE COMPLIAimm o { 7 APPROVED sCAA ERNOV 21 2017 City of Tukwila BUILDING DIVISIO 1/8"= 16 24 • FSi consulting engineers Seattle, Washington Solutions & Service SYM A REVISION IR SIGNATURE LAB B IR SIGNATURE LAB (CODE REVISION) J#190105-02 J#190105-02 BY CH/KB APPROVED DATE SYM REVISION BY APPROVED DATE 9.20.00 CH 10-31-00 C INSTALL CEILING DIFFUSER J#120706-02 DMV RWS 10.30.02 D RELOCATE BR&T STORAGE J#20368-10 EISI MW 12.15.13 E 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 Q� BOE/NG° C' - 10.31.17 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K.BUN DATE 9.20.00 APPROVED BY DEPT. DATE CHECKED C. HARRAH ENGINEER 9.20.00 SUBTITLE HVAC FIRST FLOOR PLAN CURRENT REVISION 34224 SYMBOL E DATE 10.31.17 CHECKED APPROVED APPROVED TITLE MECHANICAL MASTFR 9-110 DENSIFICATION BUILDING 9-110 COL. A—DD / 1-4L D.C. SHEET 1 M 1 0 JOB NO. J#190105-02 COMP NO. DWG NO. 9-110-1M10 FIST PLA\ SCALE: 1/8"=1 —0" CO\STUCTIO\ OTES A RECEIVED CITY OF TUKWILA NOV 6 2017 PMIT CENTER 90% SUBMITTAL OCTOBER 31, 2017 PROVIDE CURB MATCHING DIMENSIONS OF EXISTING OPENING. PROVIDE AND INSTALL AIR FILTERS IN AHU. SEE M1 FOR RATING AND SIZE. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 1 2017 City of Tukwila BUILDING DIVISION FSi consulting engineers Seattle, Washington Solutions (8c Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A 9-110 DENSIFICATION 34224 FSi AWL 10.31.17 gi_Rt.E:ermrto- 10.31.17 SMNm ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN K.BUN DATE CHECKED C.HARRAH SUBTITLE HVAC ROOF PLAN CURRENT REVISION 34224 SYMBOL A DATE 10.31.17 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER 9-110 DENSIFICATION BUILDING 9-110.1 COL. ALL D.C. SHEET RFM10 JOB NO. COMP NO. DWG NO. 9-110—RFM10