Loading...
HomeMy WebLinkAboutPermit M17-0166 - GCI - SUPPLY AND RETURN AIR DIFFUSERS, EXHAUST FANSGCI 16300 CHRISTENSEN RD 350 M17-0166 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2523049078 16300 CHRISTENSEN RD 350 Project Name: GCI Permit Number: M17-0166 Issue Date: " 11/27/2017 Permit Expires On: 5/26/2018 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: TALON RIVERVIEW PLAZA LLC 720 OLIVE WAY STE 1020 , SEATTLE, WA, 98101 JEREMY MOELLER PO BOX 3205 , KIRKLAND, WA, 98083 C F M HEATING AND COOLING INC PO BOX 3205 , KIRKLAND, WA, 98083 CFMHEHC969CD 111 Phone: (425) 821-1293 Phone: (425) 821-1293 Expiration Date: 2/4/2018 DESCRIPTION OF WORK: RELOCATE EXISTING SUPPLY AND RETURN AIR DIFFUSERS AND INSTALL 2 NEW EXHAUST FANS FOR TENANT IMPROVEMENT. ALL WORK IS INTERIOR ONLY Valuation of Work: $2,000.00 Type of Work: REPLACEMENT Fuel type: Fees Collected: $232.51 Electrical Service Provided by: PUGEST SOUND ENERGY Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2014 2014 2014 2015 Permit Center Authorized Signature: Date: I l I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: ere Mcd (z'V Date: [ -Z7 [ This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. 10: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 11: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 12: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 13: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions ofthe code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: ***MECHANICAL PERMIT CONDITIONS*** 17: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 18: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. W\ `"\ O\ ? P Project No. �1 /j Date Application Accepted: 11 LD \ t Date Application Expires: I it Is (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 16300 Gtt(t54e en F0,a King Co Assessor's Tax No.: 25230(4- ?0713 Tenant Name: CI Suite Number: 350 Floor: 3 PROPERTY OWNER Name: -rQi1o1 glvetview PIv_ LLC Address: 720 O I. Ve (oy 6u;'('e l cau City: 6e vie State: (lp Zip: c010 CONTACT PERSON — person receiving all project communication Name: Texeml KocA1or- Address: City: K., 1.�'U_ j State: we Zip: U6b8 2 I J Phone: 621- 2 Fax: 47-5- EZ1,, (3,43 �i25� (�3 Email: c eremi€CFM-tkVACt.toM New Tenant: ❑ Yes ❑ .. No MECHANICAL CONTRACTOR INFORMATION Company Name: cm t' ach T (6 artil CJobs Address:p.o. evx 3Zo5 City: K. , ` i State: I� _iA Zip:16665 1 r �I(J(IGt ��1 Phone: qz5 ,0�1- (2q3 Fax: gz5 ,60(-13 q3 Contr Reg No.CCM IleRccgp Exp Date: 0.40///6 Tukwila Business License No.: 6US_ 09991 of Valuation of project (contractor's bid price): $ 2 00 r Describe the scope of work in detail: ?e ect& exz.S1- n3 549ply' ni !e4(" G�`,v- 6;40ers and i 054011 2 new exlt w + ` thank improk,earien k'Dr 15 to'ter\c- O"I• Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line \2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Residential, Nighttime Furnace>100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system I Air handling unit 65 dB(A) <10,000 cfm 60 dB(A) Unit Type Qty Air handling unit Residential, Nighttime >10,000 cfm Industrial Evaporator cooler 55 dB(A) Ventilation fan connected to single duct 57 dB(A) Ventilation system Commercial Hood and duct 47 dB(A) Incinerator — domestic 65 dB(A) Incinerator — comm/industrial 60 dB(A) Unit Type Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) 60 dB(A) 65 dB(A) Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential zone it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* . Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) 60 dB(A) 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A) 70 dB(A) *Daytime means 7AM-1 OPM, Monday through Friday and 8AM-1 OPM, Saturday, Sunday and State -recognized holidays. A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-lOpm); • Testing of backup generators during the day. PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review —applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: Print Name: R OR AUT�� ZED AGENT: Mailing Address: � y Mc k{ �. �. 130( 3205 H:\Applications\Forms-Applications On Line \2016 Applicat ions\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Date: Day Telephone: 1175 62 ir J2g3 K-1 (1(t( 9606.3 City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ( ACCOUNT QUANTITY PAID PermitTRAK $465.02 M17-0165 Address: 635 ANDOVER PARK W 200 Apn: 2623049143 $232.51 Credit Card Fee $6.77 Credit Card Fee R000.369.908.00.00 0.00 $6.77 MECHANICAL $217.06 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $140.50 PLAN CHECK FEE 8000.322.102.00.00 0.00 $43.41 TECHNOLOGY FEE $8.68 TECHNOLOGY FEE R000.322.900.04.00 0.00 I $8.68 M17-0166 Address: 16300 CHRISTENSEN RD 350 Apn: 2523049078 $232.51 Credit Card Fee $6.77 Credit Card Fee I R000.369.908.00.00 0.00 $6.77 MECHANICAL $217.06 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $140.50 PLAN CHECK FEE R000.322.102.00.00 0.00 $43.41 TECHNOLOGY FEE $8.68 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12755 R000.322.900.04.00 0.00 $8.68 $465.02 Date Paid: Wednesday, November 08, 2017 Paid By: JEREMY MOELLER Pay Method: CREDIT CARD 718073 Printed: Wednesday, November 08, 2017 3:37 PM 1 of 1 CJ SYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 438-9350 7- 0/( Project: G -C/ Type of Inspection: , AZMA%/e%9-L , ?N Address: /40, 3 t/5Y * VAD Date Called: Special Instructions:3,-5:3Date Wanted: i2., -t1 -1 7 �rri) p.rn. Requester: Phone No: 1!/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: ©K- d2ttiu6-i1- N al -010 Inspector: Date: [z-Iq-i7 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. <PPERNflIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0166 DATE: 11/13/17 PROJECT NAME: GCI SITE ADDRESS: 16300 CHRISTENSEN RD X Original Plan Submittal Revision # before Permit Issued Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: NI mu 0611 Building Division Public Works ❑ AM ND 4-h Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 11/14/17 Structural Review Required REVIEWERc INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/12/17 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWERcb INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 C F M HEATING AND COOLINGOC Homme Espanol Contact Safety & Health Claims & Insurance 0 Washington State :Department of Labor & Industries Search L&I Page 1 of 2 A -Z Index Help My L&1 Workplace Rights Trades & Licensing C F M HEATING AND COOLING INC Owner or tradesperson Principals CLANCY, SHAUN P, PRESIDENT Doing business as C F M HEATING AND COOLING INC WA UBI No. 602 361 244 PO BOX 3205 KIRKLAND, WA 98083 425-821-1293 KING County Business type Corporation License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no, CFMHEHC969CD Effective — expiration 02/04/2004— 02/04/2018 Bond DEVELOPERS SURETY & INDEM CO Bond account no. 798903C Active. Meets current requirements. $12,000.00 Received by L&I Effective date 12/17/2008 02/04/2009 Expiration date Until Canceled Insurance AMERICAN FIRE & CASUALTY CO $1,000,000.00 Policy no. BKA54333410 Received by L&I Effective date 01/11/2017 02/04/2011 Expiration date 02/04/2018 Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period, but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602361244&LIC=CFMHEHC969CD&SAW= 11/21/2017 RELOCATE EXISTING SUPPLY DIFFUSER TO MATCH NEW FLOOR PLAN LAYOUT RECONNECT EX STING VAV BOX TYPICAL OF 7 APPLY DIFFUSERS 110 C D VENTED THE PLENUM RETURN AIR CEILING HVAC FLOOR PLAN SCALE:4"=1O" SEPARATE PE -I?M REQU RDD FOR: 0 f chanical Electrical Q'Piumbing GI/Gas Piping City of Tukwila BUILDING DIVISION REVISIONS T No changes shall b0 made to the scope of work witho: i prior approval of Tukwila Bufding Division. NOTE: Revisions will require a new plan submittal and may include additional pian review fees FILE COPY Permit No. Mt1' N4 Plan review approval is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Feld and conditions is acknowledged: By: Date: City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED NOV 21 2017 • PrJ City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV p82017 PERMIT CENTER M 11-01(0 SET DATE: 11-03-17 REVISION w 0 O z 0 J m JOB NUMBER r 0 H JEREMY MOELLER CHECKED BY • 0 u_ tU co 0 0 lc zco W co r z00 w0) Q (12 cc U� o� U(OD 0I—I-- w H 1=- HVAC FLOOR PLAN U z z O �O U °6 z SHEET NUMBER M1 .0 CONTRACTORS LICENSE CFMHEHC969CD