Permit M17-0183 - AGORA - ROOFTOP HEAT PUMP
AGORA 12600 INTERURBAN AVE S SUITE 160 M17-0183 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0004800003 Permit Number: 12600 INTERURBAN AVE S Unit160 Issue Date: Permit Expires On: Project Name: AGORA M 17-0183 12/11/2017 6/9/2018 Owner: Name: Address: Contact Person: Name: GATEWAY OLYMPIA INC PO BOX 4900 #207 , SCOTTSDALE, WA, 85261 JESSE CHUTICH Address: 3202 C ST NE , AUBURN, WA, 98002 Contractor: Name: COMFORT MECHANICAL INC (CONSTRUCT) Address: 3202 C ST NE , AUBURN, WA, 98002 License No: COMFOM1015LA Lender: Name: Address: Phone: (425) 251-9840 Phone: (425) 251-9840 Expiration Date: 4/25/2018 DESCRIPTION OF WORK: REPLACE (1) 3 -TON ROOFTOP HEAT PUMP WITH NEW LIKE UNIT Valuation of Work: $6,336.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $299.50 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer District: TUKWILA Current Codes adopted by the City of Tukwila: International Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: International Fuel Gas Code: Permit Center Authorized Signature: 2015 2015 2015 2015 2015 National Electrical Code: WA Cities Electrical Code: WAC 296-46B: WA State Energy Code: 2017 2017 2017 2015 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: eSSe. C�i 4�r`� Date: / This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. M fl /92) Project No. Date Application Accepted: \ .). t .I 7 Date Application Expires: ,Z;` ?V (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 0(90y8962 -003 Suite Number: (, 0 Floor: Site Address: 12609O r/j'-�)-'t.rba» aVe- 5 Tenant Name: AlQ to` PROPERTY OWNER Name: Jesse Chutich Name: G4 rtwot y of y tiv 76,.. City: Auburn State: WA Zip: 98002 Address: , SaMG 0'5 ss+G Email: jesse@comfoitmech.com City: • State: Zip: CONTACT PERSON — person receiving all project communication Name: Jesse Chutich Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Email: jesse@comfoitmech.com New Tenant: ❑ Yes 0 MECHANICAL CONTRACTOR INFORMATION Company Name: Comfort Mechanical Inc. Address: 3202 C St NE City: Auburn State: WA Zip: 98002 Phone: (425) 251-9840 Fax: Contr Reg No.: COMFOM1015LA Exp Date: 04/25/2018 Tukwila Business License No.: BUS -0993365 Valuation of project (contractor's bid price): $ 63, ,336 Describe the scope of work in detail: R ejfAC-C. (lS 3- ,I-oM roo-Fla? tom// 1 ke Use: Residential: New Commercial: New Fuel Type: Electric Replacement Replacement Gas ❑ Other: H:\Applications\Forms-Applications On Line\2016 Applications\Mechanical Permit Application Revised I-4-16.docx Revised: January 2016 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty. Furnace <100k btu r Furnace >100k btu Industrial Floor furnace 55 dB(A) Suspended/wall/floor mounted heater 57 dB(A) Appliance vent Commercial Repair or addition to heat/refrig/cooling system 47 dB(A) - r Air handling unit 65 dB(A) <10,000cfin 60 dB(A) • Unit Type Qty Air handling unit >10,000 cfin Residential, Nighttime Evaporator cooler Industrial Ventilation fan connected to single duct 55 dB(A) Ventilation system 57 dB(A) Hood and duct Commercial Incinerator — domestic 47 dB(A) - r Incinerator — comm/industrial 65 dB(A) Umt.:TYPe Qty Fire damper Residential, Nighttime Diffuser Industrial Thermostat 55 dB(A) Wood/gas stove 57 dB(A) Emergency generator Commercial Other mechanical equipment 47 dB(A) - r " 60.dB(A) .. 65 dB(A) Boiler/Compressor. Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Noise: ^ ., . Mechanical units need to be in compliance with the Tukwila Noise Code. Maximum permissible sound levels are based on from where the sound is created and where the sound is heard. Additionally, if sound can be heard from within a house at night in a residential ione it may not be allowed. For more details, see TMC 8.22 District of Sound Producing Source District of Receiving Property Residential, Daytime* Residential, Nighttime Commercial Industrial Residential 55 dB(A) 45 dB(A) 57 dB(A) 60 dB(A) Commercial 57 dB(A) 47 dB(A) - r " 60.dB(A) .. 65 dB(A) Industrial 60 dB(A) 50 dB(A) 65 dB(A)' . 70 dB(A) *Daytim A few sounds are exempt from the noise code, including: • Warning devices; • Construction and property maintenance during the daytime hours (7am-l0pm); • Testing of backup generators during the day. PERMIT"APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. r• BUILDING OWNER OR AUT$ORIZED AGENT: Signature: Print Name: Jesse Chutich Mailing Address: 3202 C St NE H:\Applications\Forms-Applications On Line \2016 Applications \Mechanical Permit Application Revised 1-4-16.docx Revised: January 2016 bh Date: /1/2 9/( 7 Day Telephone: (425) 251-9840 Aburn WA 98002 City State Zip t Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT QUANTITY PAID $299.50 M17-0183 Address: 12600 INTERURBAN AVE 5 Unit160 Apn: 0004800003 $299.50 Credit Card Fee $8.72 Credit Card Fee R000.369.908.00.00 0.00 $8.72 MECHANICAL $279.60 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 0.00 $33.15 PERMIT FEE R000.322.100.00.00 0.00 $190.53 PLAN CHECK FEE R000.322.102.00.00 0.00 $55.92 TECHNOLOGY FEE $11.18 TECHNOLOGY FEE TOTAL FEES PAID BY RECEIPT: R12900 R000.322.900.04.00 0.00 $11.18 $299.50 Date Paid: Thursday, November 30, 2017 Paid By: JESSE CHUTICH Pay Method: CREDIT CARD 210344 Printed: Thursday, November 30, 2017 10:44 AM 1 of 1 CSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. 0,/-7_6/F3 PERMIT NO. �� CITY OF TUKWILA BUILDING DIVISION (206) 431-3670 6300 Southcenter Blvd.., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 438-9350 Project: Type of Inspection: Address: 1.2WO 7,'7t/,Q8 Date Called: Special Instructions: Date Wanted: % `le • a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: e7i.< 4 te/, 40,7/0.2.,— Inspector: .2.,- Inspector: �-3 Date: REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 438-9350 7.-e) g3 Project: 4 GotvA Type of Inspection: AlarmI L Fl NM -- Address: 124000 tiPERUABitil J/C 9 Date Called: -� Special Instructions: awn.. / Date Wanted: C —la le ,a.m P.m. Requester: Phone No: Approved per applicable codes. 2 Corrections required prior to approval COMMENTS: , 2 !T4sg /6).44/VS' 0.4) Inspector: Date: /a2./6 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. United Technologies SUBMITTAL Project Tukwila Commerce -ALT Date Wednesday, November 22, 2017 fr1(7OlS3 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 0 8 2017 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV 30 2011 PERMIT CENTER Project: Tukwila Commerce -ALT Prepared By: 3T Pkg HP-Horiz 11/22/2017 01:31 PM 3T Pkg HP-Horiz Tag Cover Sheet Unit Report Certified Drawing Performance Report Packaged Rooftop Builder 1.49a Page 2 of 7 Project: Tukwila Commerce -ALT Prepared By: Unit Report For 3T Pkg HP-Horiz 11/22/2017 01:31 P M Unit Parameters Unit Model 50VT-C36---5 Unit Size 36 (3 Tons) Volts -Phase -Hertz. 208-3-60 Heating Type. Heat Pump Duct Cfg. Horizontal Supply / Horizontal Return Warranty Information 1 year warranty on parts 5 yearwarranty on compressor No optional warranties were selected. Dimensions (ft. in.) & Weight (1b.)*** Unit Length. 4' 0.25" Unit Width. 3' 8.1875" Unit Height 4' 0.75" *** Weights and Dimensions are approximate. Weight does not include roof curbs, unit packaging, field installed accessories or factory installed options. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. Total Operating Weight 387 Ib NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50VT-C36---5 Rooftop Unit 1 Base Unit Accessories CPCRKHTR008A00 240V Crankcase Heater 1 CPHEATER056A02 7.5/10.0 kW, 208/230-3-60 volt, Electric Heater 1 CPECOMZR012A00 Horizontal Economizer 1 CPRLYKIT001A00 Economizer relay kit for heat pumps 1 Packaged Rooftop Builder 1.49a Page 3 of 7 Certified Drawing for 3T Pkg HP-Horiz 1- J Q 8 N E E 0 U (0 T 7 m I--' -0 • 0) U N N 0 0_ d AI Packaged Rooftop Builder 1.49a MicroMetl Date: 9/19/2017 Weights: 561bs/25.4kg Units: Part Number: ECH-SPPLBSA-DWDH Submitted To: shumphries@airefco.com Job: Notes: Economizer - Standard Dry Bulb Sensor, Honeywell Included. Leak Economizer, Actuator. Painted ...lora Horizontal Orientation, Honeywell W7212 Single Speed Electromechanical Controller, Adjustable Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware rite. Filter Access Field 11111111111 Iv. Opllpllll111 ' Outside Air Provided Duct � 111111111111111 1111111011111 III11111111/ Ip'' III�III' Damper IPanel � Replacement o° °° °° x;,�1 {y'y�'' Return ,'1 Damper ' 0. 111/ -41- 28 1/2" ----►I I ° °"1:::::g�- Optional �e 0876-0300 , 1 //�/ ,�i'� Rainhood ° ° ° O °° IItyr � 1111 I I Ilyl J1 ;;ti �'(�p' yl/ Relief Damper Field Mounted to Return Duct °° °O ° ° +'dd'14' I - - - _ Hood Filter SIDE VIEW Provided Filters (1)16"x24"x 1" (1)18"x24"x 1" The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 0MicroMetl Date: 017 • Weights: 561bs/25.4kg Units: Part umber: ECH-SPPLBSA-DWDH Submitted To: shumphries@airefco.com Job: Notes: Economizer - Standard Dry Bulb Sensor, Honeywell Included. Features: Leak Economizer, Horizontal Orientation, Honeywell W7212 Single Speed Electromechanical Controller, Adjustable Actuator. Painted Rain Hood With Aluminum Filter, Barometric Relief, All Necessary Panels And Hardware installed trouble-free operation, eliminating slippage and binding associated with standard linkage. aluminum water entrainment filters in the outside air section. water run-off. needed are provided. Honeywell W7212 controller, mixed (supply) air temperature sensor, OA sensor in description, and spring -return actuator (some include differential return mounted on economizer. is field installed in indoor blower fan section. sensor (included in "-DWZS" models or can be ordered separately - MicroMetl Part No. 9901-0018) is field installed in return duct. • Includes filter rack. Field • Gear driven design for • Includes rainhood with • Rainhood is sloped for • All harnesses and plugs Notes: 1. Control systems include sensor as noted). 2. W7212 controller is factory 3. Mixed (supply) air sensor 4. Differential return enthalpy The Information contained in this drawing is the sole property of Micrometl Corporation. Any reproduction in part or whole without the written permission of Micrometl Corporation is prohibited. Indianapolis_3035 N. Shadeland Ave., Indianapolis, IN 46226_800.MMC.HVAC •• Sparks_905 Southern Way, Sparks, NV 89431_800.884.4MMC •• Longview_201 Kodak Blvd., Longview, TX 75602_903.248.4800 Performance Summary For 3T Pkg HP-Horiz Project: Tukwila Commerce -ALT Prepared By: 11/22/2017 01:31 PM Part Number:50VT-C36---5 ARI SEER 14.00 Base Unit Dimensions Unit Length:___ 48.3 in Unit Width 44.2 in Unit Height 48.8 in Total Operating Weight 387 Ib Unit Unit Voltage -Phase -Hertz. 208-3-60 Air Discharge. Jiorizontal Fan Drive Type. Direct Actual Airflow' 1185 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB 59.8 F Evaporator Leaving Air WB. 58.0 F Evaporator Leaving Air Enthalpy 25.04 BTU/Ib Net Cooling Capacity 34.14 MBH Net Sensible Capacity' 25.85 MBH Total Unit Power Input:_ 2.97 kW Coil Bypass Factor 0.049 Heating Performance Outdoor Ambient Temperature. 47.0 F Entering Air Indoor Coil DB- 70.0 F Leaving Air Indoor Coil DB. _96.9 F Total Heating Capacity 34.39 MBH Integrated Heating Capacity 34.39 MBH Heating Power Input 2.76 kW Electric Heating Capacity: 1.50 kW Unit Leaving Air Temp. 116.8 F Supply Fan External Static Pressure 0.50 in wg Options / Accessories Static Pressure Electric Heaters. 0.09 in wg Economizer 0.11 in wg Wet Coil. 0.09 in wg Total Application Static (ESP + Unit Opts/Acc.). 0.79 in wg Fan Motor Size, hp. 3/4 NOTE. High Motor Speed, Horz Electrical Data Minimum Voltage. 197 Maximum Voltage. 253 Compressor RLA. 10.4 Compressor LRA. 73 Actual Electric Heater kW. 7.5 Electric Heater FLA. 20.8 Outdoor Fan FLA (ea). 1 Indoor Fan Motor FLA. 6 Power Supply MCA. 44.2 Packaged Rooftop Builder 1.49a Page 5 of 7 Performance Summary For 3T Pkg HP-Horiz Project: Tukwila Commerce -ALT Prepared By: 11/22/2017 01:31 PM Power Supply MOCP (Fuse or HACR) 45 Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating. 74.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA NA 125 Hz NA NA 61.9 250 Hz NA NA 63.3 500 Hz NA NA 58.9 1000 Hz NA NA 59.9 2000 Hz NA NA 58.7 4000 Hz NA NA 56.2 8000 Hz NA NA 52.4 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground 5.7 ft 4. Height of obstruction:__ 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 0.0 61.9 63.3 58.9 59.9 58.7 56.2 52.4 68.3 Lw B - 26.2 45.8 54.7 55.7 59.9 59.9 57.2 51.3 65.2 LwA C 0.0 29.5 30.9 26.5 27.5 26.3 23.8 20.0 35.9 Lp D - 26.2 13.4 22.3 23.3 27.5 27.5 24.8 18.9 32.8 LpA Legend A Sound Power Levels at Units Acoustic Center, Lw B A -Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A -Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Packaged Rooftop Builder 1.49a Page 6 of 7 Performance Summary For 3T Pkg HP-Horiz Project: Tukwila Commerce -ALT Prepared By: 11/22/2017 01:31 PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.49a Page 7 of 7 50VT—C Comfort" 14 SEER Single—Packaged Heat Pump System with Puron® (R -410A) Refrigerant Single Phase 2-5 Nominal Tons (Sizes 24-60) Three Phase 3-5 Nominal Tons (Sizes 36-60) turn to the experts Product Data Fig. 1 - Unit 50VT-C Single -Packaged Products Puron® refrigerant. • Up to 14.5 SEER • Up to 12.0 EER • 8.0 HSPF • ECM Motor -Standard • Certified to leak 2% or less of nominal air conditioning CFM deliv- ered when pressurized to 1 -in. W.C. with all present air inlets, air out- lets, and condensate drain port(s) sealed. FEATURES/BENEFITS One-piece Heat Pump unit with optional electric heater, low installation cost, dependable performance and easy maintenance. Efficient operation High -efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of up to 14.5. Puron Environmentally Sound Refrigerant is Carrier's unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems, proving highly reliable, environmentally sound performance. Easy Installation Factory -assembled package is a compact, fully self-contained, heat pump unit that is prewired, pre -piped, and pre -charged for minimum installation expense. These units are available in a variety of standard capacity ranges with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. with Energy -Saving A09034 Features and Durable, dependable components Scroll Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection. ECM Motor is standard on all models. Direct -drive, PSC (Permanent Split Capacitor) condenser -fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40°F (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field installed accessory. Innovative Unit Base Design On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Thermostat Controls designed to work as a system with Cartier's small packaged product. Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full refrigerant charge. Refrigerant service connections make checking operating pressures easier. High and Low Pressure Switches provide added reliability for the compressor. Indoor and Outdoor coils are computer -designed for optimum heat transfer and efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 73dBA. Easy to service cabinets provide easy 3 panel accessibility to serviceable components during maintenance and installation. The base with integrated drain pan provides easy ground level installation with mounting pad. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4 -in. wide perimeter flange makes frame mounting on a rooftop easy. Convertible duct configuration Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow with the two standard duct covers. Downflow operation is easily provided in the field to allow vertical ductwork connections. The basepan utilizes seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Cabinets are constructed of heavyduty, phosphated, zinc -coated prepainted steel capable of withstanding 500 hours in salt spray. Interior surfaces of the evaporator and electric heater compartments are insulated with cleanable semi-rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air 1. Conditioning Engineers No. 62P.) The sloped drain pan minimizes standing water in the drain. An external drain is provided. Short -Cycling protection for the compressor is incorporated into our defrost control board ensuring a five minute delay (+/-2 minutes) before restarting compressor after shutdown for any reason. TABLE OF CONTENTS FEATURES/BENEFITS 1 MODEL NUMBER NOMENCLATURE 2 AH RI CAPACITIES 3 PHYSICAL DATA 4 OPTIONS AND ACCESSORIES 5 ROOF CURB ACCESSORY DIMENSIONS 6 BASE UNIT DIMENSIONS 7-8 SELECTION PROCEDURE 10 PERFORMANCE DATA 11-24 TYPICAL PIPING AND WIRING 25 APPLICATION DATA 26 ELECTRICAL DATA 28 TYPICAL WIRING SCHEMATICS 30-35 CONTROLS 36 GUIDE SPECIFICATIONS 37-38 MODEL NUMBER NOMENCLATURE 50VT C 24 Type of Unit 50VT — Single Packaged Heat Pump System N/A Major Series Nominal Cooling Capacity 24— 2.0 Tons 30 — 2.5 Tons 36 — 3.0 Tons 42 — 3.5 Tons 48— 4.0 Tons 60 — 5.0 Tons N/A C LISTED US 3 1 Options LT — 2% air leakage, tin plated indoor coil hairpins and louver metal outdoor grille. TP — Base unit with tin plated indoor coil hairpins (Single Phase Only) See Price Page for full list of factory options. Only used if ordering an option Minor Series Electrical Supply 3 — 208/230-1-60 5 — 208/230-3-60 6 — 460-3-60 I I...d CERTIFIED,. Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program For verification of certification for individual products, go to www.ahridirectory.org. SHRA COMPLIANT PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M17-0183 PROJECT NAME: AGORA DATE: 11/30/17 SITE ADDRESS: 12600 INTERURBAN AVE S - SUITE 160 X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # i. after Permit Issued DEPARTMENTS: k\N li4\111 uilding Divisio Public Works Alik L1---17 Fire Prevention Planning Division ❑ Structural ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE:. 12/05/17 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/02/18 Approved Corrections Required ❑ Approved with Conditions ❑ ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: 12/18/2013 COMFORT MECHANICAL INC Home Espanol Contact Safety & Health Claims & Insurance 0 Washington State Department of Labor & Industries Search L&I A -Z Index Ilelp Page 1 of 2 My 1.4d: i Workplace Rights Trades & Licensing COMFORT MECHANICAL INC Owner or tradesperson Principals JACKSON, SHIRLEY A, PRESIDENT JACKSON, HERB J, VICE PRESIDENT Doing business as COMFORT MECHANICAL INC WA UBI No. 601 954 041 3202 C ST NE AUBURN, WA 98002 425-251-9840 KING County Business type Corporation Governing persons HERB J JACKSON SHIRLEY A JACKSON; License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. COMFOMI015LA Effective — expiration 06/0111999— 04/25/2018 Active. Meets current requirements. Bond Lexon Ins Co $6,000.00 Bond account no. 9815017 Received by L&I Effective date 06/04/2012 06/01/2012 Expiration date Until Canceled Bond history Insurance AMCO Ins Co $1,000,000.00 Policy no. ACP3008276478 Received by L&I Effective date 05/24/2017 06/01/2017 Expiration date 06/01/2018 Insurance history Savings Help us improve https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601954041 &LIC=COMFOMI015LA&SAW= 12/8/2017 PROJECT DESCRIPTION: 1. REPLACE (1) 3 -TON ROOF MOUNTED PACKAGED HEAT PUMP WITH NEW 3 -TON ROOF MOUNTED PACKAGED HEAT PUMPWITH ECONOMIZER. 2.PRVID PROVIDE SIDE DISCHARGE DUCT TRANSITIONS TO TIE INTO EXISTING DUCT. Rarcel Number 000480-0003 • Name:',. GATEWAY OLYMPIA iNC • Site.. • Address 12600 INTERURBAN AVE S 98168 . . Le al 9 • LEWIS C C -D C # 37 BEG N 81-44-15 E 199.17 FT. FROM HUB AT END OF CURVE ON CENT LN OF DUWAMISH=RENTON. JUNCTION RD. SD HUB BEING APPROX 1200 FT N AND 440 FT W OF .114 COR BET SECS 14 & 15-23-4 TH N 49-24-00 W 2535 FT TH N 09-36:00 E 52 FT. TO TRUE BEG TH S 82-40-30. E 590 FT TH N 59-22-30 E. 643.35 FT TH N 01-51=30 W 343 FT TO LEFT BANK OF DUWAMISH RIVER BEING NLY OUNDRY OF LEWIS D C,TH SWLY ALG SD BANK OF RIVER TO PT N 00-39-40 W OF TRUE EEG TH S 00-39-40 E TO TRUE BEG ALSO POR OF D C LY W OF ABOVE DESCRIBED LAND SLY 16.15 FT AND A 16 FT STRIP. ADJ AND PARL TO ELY LN OF R/W OF P S ELEC CO FOR JOINT RD TGW LOT 47 OF PLAT OF. RIVERSIDE INTERURBAN TRS GENERAL NOTES: ECONOMIZER TO PROVIDE 100% OUTSIDE AiR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. EXISTING UNIT WEIGHS 425 LBS. NEW UNIT WEIGHS 387 LBS. 3 NEW UNIT TO SIT ON (2) 4X6" PRESSURE TREATED WOOD BEAMS. 4 THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 5.7 -DAY PROGRAMMABLE THERMOSTAT WiTH LOCKOUT. 6. INSTALL GFCI OUTLET WITHIN 25' OF UNIT. 7. PROVIDE COMMISSIONING REPORT. 8. VERIFY ALL DUCT DIMENSIONS PRiOR TO INSTALLATION. 9. INSULATE ALL DUCT PER WSEC. 10. SEAL ALL DUCT PER WSEC. 20' RTU -1 ±SEP_AR' T . REQUIRED FOR: viechanical lectncal �.,//Plumbing O'Gas Piping City of Tukwila BUILEMG ENViSION 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stories and all R1 � Mechanical Summar l- MECH-SUM Revised January 2017 2015 Washington State Energy Code Compliance Forms for Commercial Buildings including R2 & R3 over 3 stories and alt R1 Project Information Project Title: AGORA Date 1/1/2015 inquiries Applicant Information. Provide contact information for individual who can respond to about compliance form information provided. For Building Dept. Use Fan Power, . . Calculation Required . (Note 4) Company Name: COMFORT MECHANICAL CV Company Address:. 3202 C ST NE 0.75 Applicant Name: JESSE CHUTICH Applicant Phone: 425-251-9840; Project Description Briefly describe mechanical systems in the text box provided ❑Total Bldg Performance (TBP) This path includes all mandatory provisions per C401.2 Option 2. MECH-SUM, MECH-CHK, and C407 Energy Analysis forms required. . New Building ❑Building Addition ❑Tenant Improvement "'System Retrofit in No System Changes REPLACE (1) 3 -TON SIDE DISCHARGE ROOF MOUNTED HEAT PUMP WITH NEW LIKE UNIT. Design Load Calculations building heating, cooling or Includesall applicable: • Load calculation summary ❑ MECH-LOAD-CALL Form Provide design load calculations for all mechanical systems and equipment serving the ventilating needs. If a load calculation summary Is provided with the permit documents that compliance information then the MECH-LOAD-CALC form Is not required. Mechanical Schedules forms are not required, El Mechanical Plans ii MECH-EQ Forms (TBD) indicate location of equipment compliance information. If provided on plans then MECH-EQ however, Include on plans all applicable compliance Information listed in MECH-EQ tables. Dedicated Outdoor Air System Requirements and High Efficiency VAV Alternate fire station occupancies) air In a manner that does heating or cooling is required. Exception 1) lieu of DOAS (C403.6, Exception library or fire station) 0402.4.1.4 with 100% of • DOAS is required per C403.6 effective July 1, 2017 (office, retail, education, library and All occupied, conditioned areas shall be served by a DOAS that delivers required ventilation not require space conditioning fan operation. Space conditioning fans cycled off when no II Ventilation provided via natural ventilation per 2015 IMC in lieu of DOAS (0403.6, ntilation and space conditioning provided by a HEVAV system per C403.7 In ■ Ventilation i♦ DOAS included In project, although not required (occupancy not office, retail, education, ❑ DOAS related allowances included in project ❑ Prescriptive vertical fenestration maximum area allowance increased to 40% per conditioned floor area in building served by DOAS. Ili Exception to air economizer per C403.3 Exception 1, include MECH-ECONO form. Fan Power exceeds 5hp. the 5 horsepower threshold El Project Includes HVAC air distribution systems that provide heating and/or cooling If yes, provide a MECH-FANSYS -SUM form. Ill For one or more systems, the total fan motor nameplate hp of all fans in HVAC system If yes, provide a seperate MECH FANSYS form for each HVAC system exceeding Refer to Section C403.2.11 and MECH-FANSYS-DOG for requirements and exceptions. HVAC Hydronic Systems 4 No hydronic systems II Hydronic chilled water ❑ Water -loop heat pump ❑ Hydronic heating water i1• Geothermal Note 1- Constant Single Note 2 - Describe all supply, terminals. conditions. Note 3 - Enter Note 4 - This or this C406 Additional Efficiency Options - Mechanical Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per 0403.2.11.1 Exception 1. shall comply as CV. list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. include and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan powered -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak hp of all fans associated with the delivery and removal of conditioned air by the system. whether a MECH-FAA'SYS form is required to demonstrate compliance with the fan power allowance (Yes), because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS fame shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Fonn) to generate anadditional form. Added forms can be deleted with button in cell E32 of the added form or air -to -water heat be 15% more efficient than have FEQ a 71 and must be required ventilation air in a of annual hot water energy use be • C406.2 More efficient HVAC equipment and fan systems Requires 90% of heating and cooling capacity to be equipment listed in tables C403.2.3(1)-(9) pumps and heat recovery chillers. All equipment listed in tables C403.2.3(1)-(7) must minimum requirements. All stand alone supply, return, and exhaust fans over 1hp must selected within 10% of maximum total or static pressure. C406.6 Dedicated outdoor air system m (DOAS) Requires 90% of conditioned floor area to be served by a DOAS per C403.6 That delivers manner that does not require space conditioning fan operation. ❑ C406.7 Reduced energy in service water heating Requires 90% of floor area be in occupancy types listed in C406.7.1 and that 60% provided by heat pump, waste heat recovery or solar water -heating systems. FILE COPY (he Permit No. Ir t Of) Plan review approval is subject to errors and omissions. Approval of construction documents does net et:tnorize the violation of any adopted code or ordinanc3. Receipt of approved Field Copy and con ' ' ns is acinovviodged: By: Date: City of Tukwila BUILDING DIVISION :©.2015 MapQuest _ PQiilons 02015 TomTom (Td'rms l Privacy ROOF PLAN NO SCALE •• REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Bi iiirt'riq Division NOTE: FeviStnr' i `JI l ! : -, I ' r' n, ':tibmittl: 2015 Washington State Energy Code Compliance Forms for Commercial, R2 and R3 over 3 stones and all R1 MECH AN SYSSwUM Mechanical Fan System Power• iowance !' 1 s fo Comte al Buildin s including R2 — R3 over 3 stories and all R1 Revised January 2017 a) to t0 co co M u) N N o 00 0) art o Uf ti) N 4 0 D tri 2015 Washington State Energy Code Camp lanceorm r .,.ercl 9 Project Title: AGORA Date 1/1/2015 For Building Dept. Use HVAC Air Distribution System Schedule List all HVAC systems that have the capability to provide heating and/or cooling to the spaces they serve. System or Primary Supply Fan ID :::. Speed Control (Note 1) Description (Note 2) System Total ' Nameplate HP (Note 3) :..:. Fan Power, . . Calculation Required . (Note 4) RTU -1 . CV HEAT PUMP 0.75 No Note 1- Constant Single Note 2 - Describe all supply, terminals. conditions. Note 3 - Enter Note 4 - This or this Volume (CV), Variable zone VAV systems system type and retum/relief, exhaust VAV parallel fan the Total nameplate form automatically identifies information is not required Air Volume (VAV), or Hospital/Lab CV system that qualifies for VAV budget per 0403.2.11.1 Exception 1. shall comply as CV. list all fans (or groups of fans) associated with the delivery and removal of conditioned air by the system. include and exhaust hoods (>1 hp), make-up air, dedicated outside air (DOAS), booster fans, and series fan powered -powered terminals and economizer relief fans do not need to be included if the fans do not operate at peak hp of all fans associated with the delivery and removal of conditioned air by the system. whether a MECH-FAA'SYS form is required to demonstrate compliance with the fan power allowance (Yes), because the system has a combined total nameplate motor hp that is 5 hp or less (No) MECH-FANSYS Forms A MECH-FANSYS fame shall be provided for each system with total nameplate hp greater than 5 hp. Select (Add Fan System Fonn) to generate anadditional form. Added forms can be deleted with button in cell E32 of the added form HVAC Equipment Schedule (New) RTU -1 Brand Carrier Model 50VT-C36 Ton 3 Total CFM 1,185 Cap. Heat 34,000 Cap. Cool 3,400 SEER 14 DATE! SCALE1 PRAWN' CHECKEDi:'. CITY OF TUKWILA NOV 30 2017 PERMIT CENTER Weight 387 Sound(bels) Location 74 Roof 00.000 VU7OflS3 DEC 082017 r'P City of Tukwila BUILDING DIVISION